197 lines
5.3 KiB
Plaintext
197 lines
5.3 KiB
Plaintext
-- This file is corresponding to Release 9.1.10.101 from 2014/08/11 00:00:00
|
|
|
|
|
|
---------------------------------------------------------------------------
|
|
-- (C)opyright 2009-2014 bintec elmeg GmbH
|
|
-- $RCSfile: mib-sysped,v $
|
|
-- $Revision: 1.7 $
|
|
-- $Date: 2014-02-07 10:37:50 $
|
|
---------------------------------------------------------------------------
|
|
|
|
FEC-SYSPED-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE,
|
|
Unsigned32,
|
|
mib-2, enterprises
|
|
FROM SNMPv2-SMI
|
|
|
|
DisplayString, TimeStamp, TruthValue
|
|
FROM SNMPv2-TC
|
|
|
|
sys, Date
|
|
FROM BINTEC-MIB
|
|
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF;
|
|
|
|
---------------------------------------------------------------------------
|
|
|
|
sysPEDMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201201240000Z"
|
|
ORGANIZATION "bintec elmeg GmbH"
|
|
CONTACT-INFO
|
|
"EMail: info@bintec-elmeg.com
|
|
Web: www.bintec-elmeg.com
|
|
"
|
|
DESCRIPTION
|
|
"The MIB module for PED specific parts.
|
|
"
|
|
|
|
::= { sys 6 }
|
|
|
|
---------------------------------------------------------------------------
|
|
-- OID groups & all tables
|
|
---------------------------------------------------------------------------
|
|
sysPedRelay OBJECT IDENTIFIER ::= { sysPEDMIB 1 }
|
|
-- sysPedRelay1State 1
|
|
-- sysPedRelay2State 2
|
|
-- sysPedRelayCount 31
|
|
|
|
sysPedTemperature OBJECT IDENTIFIER ::= { sysPEDMIB 2 }
|
|
-- sysPedTemperatureCurrent 1
|
|
-- sysPedTemperatureMax 2
|
|
-- sysPedTemperatureMaxTime 3
|
|
-- sysPedTemperatureMin 4
|
|
-- sysPedTemperatureMinTime 5
|
|
-- sysPedTemperatureUpdatePeriod 6
|
|
-- sysPedTemperatureLowerThreshold 7
|
|
-- sysPedTemperatureUpperThreshold 8
|
|
-- sysPedTemperatureAlarm 9
|
|
|
|
|
|
---------------------------------------------------------------------------
|
|
|
|
---------------------------------------------------------------------------
|
|
-- sysPedRelais
|
|
---------------------------------------------------------------------------
|
|
|
|
sysPedRelay1State OBJECT-TYPE
|
|
SYNTAX INTEGER { open(1), closed(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Relay control.
|
|
open : Relay is open.
|
|
closed: Relay is closed.
|
|
|
|
Default state is open."
|
|
DEFVAL { open }
|
|
::= { sysPedRelay 1 }
|
|
|
|
sysPedRelay2State OBJECT-TYPE
|
|
SYNTAX INTEGER { open(1), closed(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Relay control.
|
|
open : Relay is open.
|
|
closed: Relay is closed.
|
|
|
|
Default state is open."
|
|
DEFVAL { open }
|
|
::= { sysPedRelay 2 }
|
|
|
|
sysPedRelayCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of available relays in the system."
|
|
::= { sysPedRelay 31 }
|
|
|
|
---------------------------------------------------------------------------
|
|
|
|
---------------------------------------------------------------------------
|
|
-- sysPedTemperature
|
|
---------------------------------------------------------------------------
|
|
|
|
sysPedTemperatureCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..150)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Temperature during the last measurement time."
|
|
::= { sysPedTemperature 1 }
|
|
|
|
sysPedTemperatureMax OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..150)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum observed temperature."
|
|
::= { sysPedTemperature 2 }
|
|
|
|
sysPedTemperatureMaxTime OBJECT-TYPE
|
|
SYNTAX Date
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Point in time the maximum temperature was observed."
|
|
::= { sysPedTemperature 3 }
|
|
|
|
sysPedTemperatureMin OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..150)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum observed temperature."
|
|
::= { sysPedTemperature 4 }
|
|
|
|
sysPedTemperatureMinTime OBJECT-TYPE
|
|
SYNTAX Date
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Point in time the minimum temperature was observed."
|
|
::= { sysPedTemperature 5 }
|
|
|
|
sysPedTemperatureUpdatePeriod OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Measurement interval of temperature update in seconds.
|
|
0: Disable measurements."
|
|
DEFVAL { 10 }
|
|
::= { sysPedTemperature 6 }
|
|
|
|
sysPedTemperatureLowerThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..125)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimal allowed temperature. If temperature falls below
|
|
this threshold, a syslog message is generated."
|
|
DEFVAL { -25 }
|
|
::= { sysPedTemperature 7 }
|
|
|
|
sysPedTemperatureUpperThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER (-55..125)
|
|
UNITS "degree Centigrade"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximal allowed temperature. If temperature raises above
|
|
this threshold, a syslog message is generated."
|
|
DEFVAL { 70 }
|
|
::= { sysPedTemperature 8 }
|
|
|
|
sysPedTemperatureAlarm OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the defined temperature thresholds are
|
|
violated."
|
|
DEFVAL { false }
|
|
::= { sysPedTemperature 9 }
|
|
|
|
---------------------------------------------------------------------------
|
|
END
|