Observium_CE/mibs/aperto/BSUSUSTATUS-MIB

338 lines
8.1 KiB
Plaintext

BSUSUSTATUS-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, Integer32
FROM SNMPv2-SMI
IpAddress
FROM RFC1155-SMI
MacAddress, DisplayString
FROM SNMPv2-TC
aniBsuWirelessPort
FROM BSUWIRELESSIF-MIB
aniBsuSuGroup
FROM ANIROOT-MIB;
aniBsuSuStatus MODULE-IDENTITY
LAST-UPDATED "0105091130Z" -- Wed May 9 11:30:00 PDT 2001
ORGANIZATION "Aperto Networks"
CONTACT-INFO
"
Postal: Aperto Networks Inc
1637 S Main Street
Milpitas, California 95035
Tel: +1 408 719 9977
"
DESCRIPTION
"This group allows the users of the BSU to access status
information about the SU.
It consists of 2 tables - The Upstream Link Status Table
and Downstream Link Status Table.
"
::= { aniBsuSuGroup 3 }
aniBsuSuUSLinkStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AniBsuSuUSLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table accesses the upstream status attributes of
each SU connected to this BSU.
"
::= { aniBsuSuStatus 1 }
aniBsuSuUSLinkStatusEntry OBJECT-TYPE
SYNTAX AniBsuSuUSLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Upstream Status information for a single SU.
An entry in this table exists for each SU that is connected
to the BSU.
"
INDEX { aniBsuWirelessPort, aniBsuSuStatusMacAddr }
::= { aniBsuSuUSLinkStatusTable 1 }
AniBsuSuUSLinkStatusEntry ::= SEQUENCE {
aniBsuSuStatusMacAddr MacAddress,
aniBsuSuStatusIpAddr IpAddress,
aniBsuSuStatusUSPolarization INTEGER,
aniBsuSuStatusUSModulation INTEGER,
aniBsuSuStatusUSFec INTEGER,
aniBsuSuStatusSuTxPowerAttn Integer32,
aniBsuSuStatusUSRxPower Integer32,
aniBsuSuStatusSuTxPower Integer32
}
aniBsuSuStatusMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SU MAC Address.
"
::= { aniBsuSuUSLinkStatusEntry 1 }
aniBsuSuStatusIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SU IP Address.
"
::= { aniBsuSuUSLinkStatusEntry 2 }
aniBsuSuStatusUSPolarization OBJECT-TYPE
SYNTAX INTEGER {
horizontal(1),
vertical(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The upstream Polarization.
This field is used by SU to adjust the polarization
selection when transmitting a burst to the BSU.
Each SU has a single antenna which can be polarized
either horizontally(1) or vertically(2).
"
::= { aniBsuSuUSLinkStatusEntry 3 }
aniBsuSuStatusUSModulation OBJECT-TYPE
SYNTAX INTEGER {
qpsk(1),
qam16(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current upstream Modulation for this SU.
"
::= { aniBsuSuUSLinkStatusEntry 4 }
aniBsuSuStatusUSFec OBJECT-TYPE
SYNTAX INTEGER {
low(1),
high(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current upstream FEC method for this SU.
"
::= { aniBsuSuUSLinkStatusEntry 5 }
aniBsuSuStatusSuTxPowerAttn OBJECT-TYPE
SYNTAX Integer32 (4..62)
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SU Tx Power Attenuation.
"
::= { aniBsuSuUSLinkStatusEntry 6 }
aniBsuSuStatusUSRxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Upstream Receive Power. The value -130 is considered invalid.
"
::= { aniBsuSuUSLinkStatusEntry 7 }
aniBsuSuStatusSuTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Upstream SU Tx Power. The value -130 is considered invalid.
"
::= { aniBsuSuUSLinkStatusEntry 8 }
aniBsuSuDSLinkStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AniBsuSuDSLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table accesses the downstream status attributes of
each SU connected to this BSU.
"
::= { aniBsuSuStatus 2 }
aniBsuSuDSLinkStatusEntry OBJECT-TYPE
SYNTAX AniBsuSuDSLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Downstream Status information for a single SU.
An entry in this table exists for each SU that is connected
to the BSU.
"
INDEX { aniBsuWirelessPort, aniBsuSuStatusMacAddr }
::= { aniBsuSuDSLinkStatusTable 1 }
AniBsuSuDSLinkStatusEntry ::= SEQUENCE {
aniBsuSuStatusDSPolarization INTEGER,
aniBsuSuStatusDSModulation INTEGER,
aniBsuSuStatusDSFec INTEGER,
aniBsuSuStatusDSRxPower DisplayString,
aniBsuSuStatusBsuTxPower Integer32
}
aniBsuSuStatusDSPolarization OBJECT-TYPE
SYNTAX INTEGER {
horizontal(1),
vertical(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The downstream Polarization.
This field is used by BSU to adjust the polarization
selection when transmitting a burst to the SU.
Each SU has a single antenna which can be polarized
either horizontally(1) or vertically(2).
"
::= { aniBsuSuDSLinkStatusEntry 1 }
aniBsuSuStatusDSModulation OBJECT-TYPE
SYNTAX INTEGER {
qpsk(1),
qam16(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current downstream Modulation for this SU.
"
::= { aniBsuSuDSLinkStatusEntry 2 }
aniBsuSuStatusDSFec OBJECT-TYPE
SYNTAX INTEGER {
low(1),
high(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current downstream FEC method for this SU.
"
::= { aniBsuSuDSLinkStatusEntry 3 }
aniBsuSuStatusDSRxPower OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Downstream Receive Power in dBm. It consists of 2
values, one for vertical polarization and one for
horizontal polarization.
It is displayed as 'vertical,horizontal'
When nothing is being received, a value NA is displayed.
Eg. for vertical = -20 and horizontal = NA, the agent
will display '-20,NA'.
"
::= { aniBsuSuDSLinkStatusEntry 5 }
aniBsuSuStatusBsuTxPower OBJECT-TYPE
SYNTAX Integer32
UNITS "dBm"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The BSU Tx Power for a particular SU.
"
::= { aniBsuSuDSLinkStatusEntry 6 }
aniBsuSuLinkStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AniBsuSuLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table accesses the other link status attributes of
each SU connected to this BSU.
"
::= { aniBsuSuStatus 3 }
aniBsuSuLinkStatusEntry OBJECT-TYPE
SYNTAX AniBsuSuLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Link Status information for a single SU.
An entry in this table exists for each SU that is connected
to the BSU.
"
INDEX { aniBsuWirelessPort, aniBsuSuStatusMacAddr }
::= { aniBsuSuLinkStatusTable 1 }
AniBsuSuLinkStatusEntry ::= SEQUENCE {
aniBsuSuStatusIpAddress IpAddress,
aniBsuSuStatusPropagationDelay Integer32,
aniBsuSuStatusDistance DisplayString,
aniBsuSuStatusLinkType DisplayString,
aniBsuSuStatusPathLossExponent DisplayString
}
aniBsuSuStatusIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SU IP Address.
"
::= { aniBsuSuLinkStatusEntry 1 }
aniBsuSuStatusPropagationDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time taken to transmit a packet from BSU to SU
(or vice versa) in microseconds.
"
::= { aniBsuSuLinkStatusEntry 2 }
aniBsuSuStatusDistance OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The distance in meters between the BSU and SU.
"
::= { aniBsuSuLinkStatusEntry 3 }
aniBsuSuStatusLinkType OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link type for a particular SU.
"
::= { aniBsuSuLinkStatusEntry 4 }
aniBsuSuStatusPathLossExponent OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The path loss exponent from BSU to SU
"
::= { aniBsuSuLinkStatusEntry 5 }
END