261 lines
7.3 KiB
Plaintext
261 lines
7.3 KiB
Plaintext
--------------------------------------------------------------------------------
|
|
--ACMEPACKET-EMS-MIB: Acme Packet EMS MIB file
|
|
--
|
|
--March 2007
|
|
--
|
|
--Copyright (c) by Acme Packet, Inc.
|
|
--All rights reserved.
|
|
--------------------------------------------------------------------------------
|
|
--This MIB provides a means to gather information about the
|
|
--Acme Management Interface running at the Net-Net EMS and/or Device
|
|
--
|
|
|
|
APEMS-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE, Integer32
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
DisplayString, TruthValue
|
|
FROM SNMPv2-TC
|
|
acmepacketMgmt
|
|
FROM ACMEPACKET-SMI;
|
|
|
|
apEMSModule MODULE-IDENTITY
|
|
LAST-UPDATED "201207160000Z"
|
|
ORGANIZATION "Acme Packet, Inc"
|
|
CONTACT-INFO " Customer Service
|
|
Postal: Acme Packet, Inc
|
|
100 Crosby Drive
|
|
Bedford, MA 01730
|
|
US
|
|
Tel: 1-781-328-4400
|
|
E-mail: support@acmepacket.com"
|
|
DESCRIPTION "The Net-Net EMS MIB for Acme Packet"
|
|
REVISION "201207160000Z"
|
|
DESCRIPTION "Updated contact information"
|
|
::= { acmepacketMgmt 8 }
|
|
|
|
|
|
apEMSMIBObjects OBJECT IDENTIFIER ::= { apEMSModule 1 }
|
|
|
|
apEMSNotificationObjects OBJECT IDENTIFIER ::= { apEMSModule 2 }
|
|
|
|
apEMSDiscoveryMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
discovery(1),
|
|
reDiscovery(2)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The discovery mode"
|
|
::= { apEMSNotificationObjects 1 }
|
|
|
|
|
|
apEMSNodeID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The identifier for a Net-Net EMS node. This is the
|
|
identifier that appears on the navigation tree in
|
|
the Active Configuration area and on the discovery
|
|
table in the Host Name/IP Address column"
|
|
::= { apEMSNotificationObjects 2 }
|
|
|
|
apEMSStartTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Time as configured at the Net-Net EMS server when
|
|
an event occurs."
|
|
::= { apEMSNotificationObjects 3 }
|
|
|
|
apEMSDateTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Time as configured at the Net-Net EMS server when an
|
|
event completes."
|
|
::= { apEMSNotificationObjects 4 }
|
|
|
|
apEMSUser OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The user initiating the function.
|
|
If the function was initiated by the Net-Net EMS
|
|
application automatically, the
|
|
user will be system."
|
|
::= { apEMSNotificationObjects 5 }
|
|
|
|
|
|
apEMSDeviceAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The address for a device being managed."
|
|
::= { apEMSNotificationObjects 6 }
|
|
|
|
|
|
apEMSFunction OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(0),
|
|
discovery(1),
|
|
reDiscovery(2),
|
|
save(3)
|
|
}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "The function being performed when the event occurred."
|
|
::= { apEMSNotificationObjects 7 }
|
|
|
|
apEMSNotifications OBJECT IDENTIFIER ::= { apEMSModule 3 }
|
|
apEMSConfigNotificationsPrefix
|
|
OBJECT IDENTIFIER ::= { apEMSNotifications 1 }
|
|
apEMSConfigNotifications
|
|
OBJECT IDENTIFIER ::= { apEMSConfigNotificationsPrefix 0 }
|
|
|
|
apEMSDiscoveryFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
apEMSDiscoveryMode,
|
|
apEMSNodeID,
|
|
apEMSStartTime,
|
|
apEMSDateTime,
|
|
apEMSUser
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification will be generated whenever an error
|
|
is detected during node discovery. "
|
|
::= { apEMSConfigNotifications 1 }
|
|
|
|
|
|
apEMSSaveFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
apEMSNodeID,
|
|
apEMSStartTime,
|
|
apEMSDateTime,
|
|
apEMSUser
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification will be generated whenever an save
|
|
configuration request initiated by Net-Net EMS fails. "
|
|
::= { apEMSConfigNotifications 2 }
|
|
|
|
apEMSActivateFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
apEMSNodeID,
|
|
apEMSStartTime,
|
|
apEMSDateTime,
|
|
apEMSUser
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification will be generated whenever an activate
|
|
configuration request initiated by Net-Net EMS fails`. "
|
|
::= { apEMSConfigNotifications 3 }
|
|
|
|
apEMSInvalidConfigDiscovered NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
apEMSNodeID,
|
|
apEMSDateTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification will be generated whenever an invalid
|
|
configuration is retrieved from a node. Additional information
|
|
about the validity failure is available in the discovery log."
|
|
::= { apEMSConfigNotifications 4 }
|
|
|
|
|
|
apEMSInvalidConfigInventory NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
apEMSFunction,
|
|
apEMSNodeID,
|
|
apEMSStartTime,
|
|
apEMSDateTime,
|
|
apEMSUser
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification will be generated whenever an inventory check
|
|
was performed and failed."
|
|
::= { apEMSConfigNotifications 5 }
|
|
|
|
apEMSDeviceHealthNotificationsPrefix
|
|
OBJECT IDENTIFIER ::= { apEMSNotifications 2 }
|
|
apEMSDeviceHealthNotifications
|
|
OBJECT IDENTIFIER ::= { apEMSDeviceHealthNotificationsPrefix 0 }
|
|
|
|
apEMSNodeUnreachable NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
apEMSDeviceAddress,
|
|
apEMSDateTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification will be generated whenever a managed device is
|
|
determined to be unreachable from the Net-Net EMS server. "
|
|
::= { apEMSDeviceHealthNotifications 1 }
|
|
|
|
|
|
apEMSNodeUnreachableClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
apEMSDeviceAddress,
|
|
apEMSDateTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The notification will be generated whenever a previously
|
|
unreachable managed device is determined to be reachable
|
|
by the Net-Net EMS server. "
|
|
::= { apEMSDeviceHealthNotifications 2 }
|
|
|
|
apEMSModuleConformance OBJECT IDENTIFIER ::= { apEMSModule 4 }
|
|
|
|
apEMSGroups OBJECT IDENTIFIER ::= { apEMSModuleConformance 1 }
|
|
apEMSNotificationsGroups OBJECT IDENTIFIER ::= { apEMSModuleConformance 2 }
|
|
apEMSNotificationObjectsGroups OBJECT IDENTIFIER ::= { apEMSModuleConformance 3 }
|
|
|
|
apEMSConfigNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
apEMSDiscoveryFailure,
|
|
apEMSSaveFailure,
|
|
apEMSActivateFailure,
|
|
apEMSInvalidConfigDiscovered
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Provisioning notifications generated by the Net-Net EMS"
|
|
::= { apEMSNotificationsGroups 1 }
|
|
|
|
apEMSDeviceHealthNotificationsGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
apEMSNodeUnreachable,
|
|
apEMSNodeUnreachableClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Device reachability notifications generated by
|
|
the Net-Net EMS"
|
|
::= { apEMSNotificationsGroups 2 }
|
|
|
|
apEMSNotificationObjectsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
apEMSDiscoveryMode,
|
|
apEMSNodeID,
|
|
apEMSStartTime,
|
|
apEMSDateTime,
|
|
apEMSUser,
|
|
apEMSDeviceAddress,
|
|
apEMSFunction
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Objects for EMS Server reachability notifications."
|
|
::= { apEMSNotificationObjectsGroups 1 }
|
|
|
|
END
|
|
|
|
|