-- This MIB is for 3Com intermediate systems to provide general
-- systems level information.
-- The 3Com Enterprise Products Proprietary MIB Extensions
-- Copyright 3Com Corporation, 1993. All rights reserved.
A3Com-System-r8-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, IpAddress, Counter, TimeTicks
FROM RFC1155-SMI
DisplayString
FROM RFC1213-MIB
MacAddress
FROM RFC1286-MIB
TRAP-TYPE
FROM RFC-1215
OBJECT-TYPE
FROM RFC-1212;
--
-- This MIB is for General 3Com Systems.
--
a3Com OBJECT IDENTIFIER ::= { enterprises 43 }
brouterMIB OBJECT IDENTIFIER ::= { a3Com 2 }
a3ComSys OBJECT IDENTIFIER ::= { brouterMIB 13 }
a3ComSysID OBJECT IDENTIFIER ::= { a3ComSys 1 }
a3ComChip OBJECT IDENTIFIER ::= { a3ComSys 2 }
a3ComMem OBJECT IDENTIFIER ::= { a3ComSys 3 }
a3ComBrd OBJECT IDENTIFIER ::= { a3ComSys 4 }
a3ComAudit OBJECT IDENTIFIER ::= { a3ComSys 5 }
a3ComTime OBJECT IDENTIFIER ::= { a3ComSys 6 }
a3ComAccCtl OBJECT IDENTIFIER ::= { a3ComSys 7 }
a3ComSysMisc OBJECT IDENTIFIER ::= { a3ComSys 8 }
a3ComFW OBJECT IDENTIFIER ::= { a3ComSys 9 }
a3ComBoot OBJECT IDENTIFIER ::= { a3ComSys 10 }
a3ComLastBoot OBJECT IDENTIFIER ::= { a3ComSys 11 }
a3ComFileMgmt OBJECT IDENTIFIER ::= { a3ComSys 12 }
a3ComFileList OBJECT IDENTIFIER ::= { a3ComFileMgmt 9 }
a3ComFmCksum OBJECT IDENTIFIER ::= { a3ComFileMgmt 10 }
a3ComFileInfo OBJECT IDENTIFIER ::= { a3ComFileMgmt 11 }
a3ComRecovery OBJECT IDENTIFIER ::= { a3ComSys 13 }
RowStatus ::= INTEGER {
active(1),
notInService(2),
notReady(3),
createAndGo(4),
createAndWait(5),
destroy(6)
}
--This data type, which has the same semantics as the rowStatus
--textual convention used in SNMPv2, is used to add and
--delete entries from a table.
--The tables in this MIB allow a subset of the functionality
--provided by the rowStatus textual convention. In particular
--row creation is allowed using only the createAndGo method.
--That is, when adding entries to this table, this object
--must be set to createAndGo(4). The instance identifier
--for this object will define the values of the columns
--that make up the index.
--In the same PDU, the appropriate remaining columns
--of that row must be set as well. The agent
--will immediately set the value of this object to
--active(1) if the row is correct. If not, the agent
--will refuse the SET request and return an
--error code.
--To modify an existing entry, it must be removed
--and another entry with the desired changes added.
--To remove an entry, set the value of this object
--to destroy(6).
--
-- The ID Group
--
a3sysVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A text string containing general system information,
including the package identifier and the system's
software release number."
::= { a3ComSysID 1 }
a3sysPlatformDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A text string describing the physical platform
or chassis on which the system is running."
::= { a3ComSysID 2 }
a3sysPlatformID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An OID defining the system platform."
::= { a3ComSysID 3 }
a3sysCallerID OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A text string defined by the user. This
string can be used by a system running PPP
as a unique identification of itself to
its peer when communicating over a PPP link. "
::= { a3ComSysID 4 }
--
-- The Chip group
--
a3sysChipTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysChipEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains information about the
chips that are used in the CPU board of the
system."
REFERENCE
"NetBuilderII Ref. Guide: System Service
Parameters: CPUboardInfo"
::= { a3ComChip 1 }
a3sysChipEntry OBJECT-TYPE
SYNTAX A3sysChipEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table contains information
about one of the chips installed in the CPU
module."
REFERENCE
"NetBuilderII Ref. Guide: System Service
Parameters: CPUboardInfo"
INDEX { a3sysChipSlotIndex, a3sysChipIndex }
::= { a3sysChipTable 1 }
A3sysChipEntry ::=
SEQUENCE {
a3sysChipSlotIndex INTEGER,
a3sysChipIndex INTEGER,
a3sysChipName DisplayString,
a3sysChipDescr DisplayString
}
a3sysChipSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies a specific slot (and
hence, a specific board). All the Chips
described with this index are located
on a single board."
::= { a3sysChipEntry 1 }
a3sysChipIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies a specific chip on the board
identified by a3sysChipSlotIndex."
::= { a3sysChipEntry 2 }
a3sysChipName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides a readable name for the chip."
::= { a3sysChipEntry 3 }
a3sysChipDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This provides general information about
the chip, including its part number and
revision number."
::= { a3sysChipEntry 4 }
--
-- The Memory group
--
a3sysMemTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains information about the
system's memory configurations."
::= { a3ComMem 1 }
a3sysMemEntry OBJECT-TYPE
SYNTAX A3sysMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table contains information
about a specific memory component. The
information includes the memory type, its
starting address and its size."
INDEX { a3sysMemSlotIndex, a3sysMemIndex}
::= { a3sysMemTable 1 }
A3sysMemEntry ::=
SEQUENCE {
a3sysMemSlotIndex
INTEGER,
a3sysMemIndex
INTEGER,
a3sysMemType
INTEGER,
a3sysMemStartAdd
INTEGER,
a3sysMemSize
INTEGER
}
a3sysMemSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies the slot (and hence the board)
that supports the memory elements identified
by this entry in the table."
::= { a3sysMemEntry 1 }
a3sysMemIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index into this table. Each memory component
is identified by a unique value of this object.
This is specific to the board identified by
a3sysMemSlotIndex."
::= { a3sysMemEntry 2 }
a3sysMemType OBJECT-TYPE
SYNTAX INTEGER {
other (1),
ram-instruction (2),
ram-data (3),
ram-shared (4),
rom-fprom (5),
rom-eeprom (6),
ram-total (7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the type of the memory
component."
::= { a3sysMemEntry 3 }
a3sysMemStartAdd OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The starting address of the memory component."
::= { a3sysMemEntry 4 }
a3sysMemSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the memory component, in bytes."
::= { a3sysMemEntry 5 }
--
-- The Board group
--
-- This group contains information about all the boards installed
-- on the system. This includes IO boards and CPU boards.
--
-- (The objects relating to boards may migrate to the Chassis MIB
-- once it's defined.)
--
a3sysSlotNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of slots (empty or not) in the system"
::= { a3ComBrd 1 }
a3sysBrdTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysBrdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table that contains information about the IO boards
in this system."
::= { a3ComBrd 2 }
a3sysBrdEntry OBJECT-TYPE
SYNTAX A3sysBrdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information for each IO board in the
system."
INDEX { a3sysSlotIndex }
::= { a3sysBrdTable 1 }
A3sysBrdEntry ::=
SEQUENCE {
a3sysSlotIndex
INTEGER,
a3sysBrdDescr
DisplayString,
a3sysBrdPathCapacity
INTEGER,
a3sysBrdOID
OBJECT IDENTIFIER,
a3sysBrdReset
INTEGER,
a3sysBrdFwVers
OBJECT IDENTIFIER
}
a3sysSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number which this board occupies."
::= { a3sysBrdEntry 1 }
a3sysBrdDescr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This contains general information about the
Board, including the model type, the serial
number, and manufacturing information."
::= { a3sysBrdEntry 2 }
a3sysBrdPathCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of physical ports supported by
this board."
::= { a3sysBrdEntry 3 }
a3sysBrdOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Object Identifier assigned to this
Board."
::= { a3sysBrdEntry 4 }
a3sysBrdReset OBJECT-TYPE
SYNTAX INTEGER {
other (1),
reset (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this object is set to reset(2), the IO
board in the slot specified by this instance
identifier of this object is reset. If a GET
request is sent for the value of this object,
other(1) is returned."
::= { a3sysBrdEntry 5 }
a3sysBrdFwVers OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the version of the firmware
that is running on this network interface board.
A list of all the OIDs assigned to 3Com router
firmware can be ftp'd from ftp.3com.com."
::= { a3sysBrdEntry 6 }
--
-- Audit trail group
--
a3sysAuditTrailType OBJECT-TYPE
SYNTAX INTEGER {
local (1), -- use local time
universal (2) -- use universal or GMT
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object allows the user to determine the format
of the time/date stamp that is included with each
audit trail message the system generates. This
only applies if there is a Network Control Server
for the IBM PC/AT (NCS/AT) or Remote Boot and
Configuration Services (RBCS) server on the attached
network. Audit trail messages are generated by
various network events and are displayed on the
NCS or RBCS console."
::= { a3ComAudit 1 }
a3sysLogServerAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS deprecated
DESCRIPTION
"The address of the NCS or the RBCS that serves
as the log server for the system. The log server
receives all of the system's audit trail messages."
::= { a3ComAudit 2 }
--
-- The Time group
--
a3sysDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The current date and time as reflected by the
system clock. The date is displayed via the User
interface and Audit Trail Messages as
yy/mm/dd hh:mm[:ss]. This same format must be
used when setting the Date."
::= { a3ComTime 1 }
a3sysDSTime OBJECT-TYPE
SYNTAX INTEGER (-120..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter specifies the displacement, in
minutes, from non-daylight savings time. The
a3sysDSTime object, along with the a3sysTimeZone
object, allows the system to support Universal
time for network communications spanning different
time zones."
::= { a3ComTime 2 }
a3sysTimeZone OBJECT-TYPE
SYNTAX INTEGER (-720..720)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies the number of minutes
displacement west of Greenwich the system's site
is located. A negative number for this parameter
indicates how many minutes displacement east of
Greenwich the site is located. A positive number
indicates the number of minutes west of Greenwich."
::= { a3ComTime 3 }
--
-- The Access Control Group
--
a3sysRemoteAccess OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determines whether another device
can access this system via REMOTE"
::= { a3ComAccCtl 1 }
a3sysTelnetAccess OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determines whether another device
can access this system via TELNET"
::= { a3ComAccCtl 2 }
a3sysConsoleAccess OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determines whether another device
can access this system via the Console"
::= { a3ComAccCtl 3 }
a3sysSNMPAccess OBJECT-TYPE
SYNTAX INTEGER {
enabledTraps (1),
enabledNoTraps (2),
disabledTraps (3),
disabledNoTraps (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determines whether another device
can access this system via SNMP. Note, once
SNMP access is disabled, the NMS will no longer
be able to access this system via SNMP.
If this is set to enabledTraps(1), the system
allows SNMP access and will send traps when
appropriate.
If this is set to enabledNoTraps(2), the system
allows SNMP access, but no traps will be sent.
If this is set to disabledTraps, the system
does not allow SNMP access, but will send
traps when appropriate.
If this is set to disabledNoTraps(4), the system
does not allow SNMP access and does not
send any traps."
::= { a3ComAccCtl 4 }
--
-- This table contains the SNMPv1 Community Strings
--
a3sysSNMPCommTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysSNMPCommEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains all the community strings
known to the SNMP agent."
::= { a3ComAccCtl 5 }
a3sysSNMPCommEntry OBJECT-TYPE
SYNTAX A3sysSNMPCommEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in the table contains information
about a single community string. "
INDEX { a3sysSNMPCommString }
::= { a3sysSNMPCommTable 1 }
A3sysSNMPCommEntry ::=
SEQUENCE {
a3sysSNMPCommString DisplayString (SIZE(1..15)),
a3sysSNMPCommAccess INTEGER,
a3sysSNMPCommTrap INTEGER,
a3sysSNMPCommStatus RowStatus
}
a3sysSNMPCommString OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies a specific community string."
::= { a3sysSNMPCommEntry 1 }
a3sysSNMPCommAccess OBJECT-TYPE
SYNTAX INTEGER {
readOnly (1),
readWrite (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This identifies the level of access allowed
for this community string."
DEFVAL { readOnly }
::= { a3sysSNMPCommEntry 2 }
a3sysSNMPCommTrap OBJECT-TYPE
SYNTAX INTEGER {
genericOnly (1), -- coldStart, warmStart, linkDown/Up
authenOnly (2), -- authenticationFailure
allTraps (3),
noTraps (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies which traps get sent to the
managers specified by this community string."
DEFVAL { noTraps }
::= { a3sysSNMPCommEntry 3 }
a3sysSNMPCommStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to add and delete
entries in this table. See the notes
describing RowStatus at the beginning
of this MIB."
::= { a3sysSNMPCommEntry 4 }
--
-- This table contains the Managers that are allowed to use
-- each of the community strings identified above.
--
a3sysSNMPMgrTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysSNMPMgrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the Managers that
are allowed to use the community strings
identified in a3sysSNMPCommTable. Each
Manager is identified by its IP address."
::= { a3ComAccCtl 6 }
a3sysSNMPMgrEntry OBJECT-TYPE
SYNTAX A3sysSNMPMgrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry identifies a single Manager,
community string pair."
INDEX { a3sysSNMPMgrCommString, a3sysSNMPMgrAddress }
::= { a3sysSNMPMgrTable 1 }
A3sysSNMPMgrEntry ::=
SEQUENCE {
a3sysSNMPMgrCommString DisplayString (SIZE(1..15)),
a3sysSNMPMgrAddress IpAddress,
a3sysSNMPMgrMask IpAddress,
a3sysSNMPMgrStatus RowStatus
}
a3sysSNMPMgrCommString OBJECT-TYPE
SYNTAX DisplayString (SIZE(1..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies a specific community string."
::= { a3sysSNMPMgrEntry 1 }
a3sysSNMPMgrAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies a single Management station
that is allowed to use the community string
associated with this entry. The set of all
entries with same value of a3sysSNMPMgrCommString
identifies all the Managers that are allowed
to use that community string."
::= { a3sysSNMPMgrEntry 2 }
a3sysSNMPMgrMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object can be used to mask part of the
IP address specified by a3sysSNMPMgrAddress.
The use of this mask can then be used to identify
a range of addresses that are allowed to use
this community string."
::= { a3sysSNMPMgrEntry 3 }
a3sysSNMPMgrStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to add and delete entries
in this table. See the notes describing
RowStatus at the beginning of this MIB for
specific instructions on how to do this."
::= { a3sysSNMPMgrEntry 4 }
--
-- This table contains the IP addresses of
-- stations that are allowed to access the NetBuilder
-- via Telnet
--
a3sysTelnetMgrTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysTelnetMgrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the IP addresses that
are allowed to use Telnet to access to
the NetBuilder in the TelnetManager table."
::= { a3ComAccCtl 7 }
a3sysTelnetMgrEntry OBJECT-TYPE
SYNTAX A3sysTelnetMgrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry identifies a single Manager,
community string pair."
INDEX { a3sysTelnetMgrAddress }
::= { a3sysTelnetMgrTable 1 }
A3sysTelnetMgrEntry ::=
SEQUENCE {
a3sysTelnetMgrAddress IpAddress,
a3sysTelnetMgrStatus RowStatus
}
a3sysTelnetMgrAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies a single Management station
that is allowed to use the Telnet to manage
the NetBuilder. Maximally, six (6)
IP addresses can be configured in each NB."
::= { a3sysTelnetMgrEntry 1 }
a3sysTelnetMgrStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to add and delete entries
in this table. See the notes describing
RowStatus at the beginning of this MIB for
specific instructions on how to do this."
::= { a3sysTelnetMgrEntry 2 }
a3sysPasswordTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysPasswordEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the system's passwords."
::= { a3ComAccCtl 8 }
a3sysPasswordEntry OBJECT-TYPE
SYNTAX A3sysPasswordEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry identifies a single system password."
INDEX { a3sysUserName, a3sysOldPassword }
::= { a3sysPasswordTable 1 }
A3sysPasswordEntry ::=
SEQUENCE {
a3sysPwStatus INTEGER,
a3sysUserName DisplayString,
a3sysUserLevel INTEGER,
a3sysOldPassword DisplayString,
a3sysNewPassword DisplayString
}
a3sysPwStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User Status. `invalid' is used to indicate this user
is no longer allowed to access this device, and the
table entry may subsequently be re-used. Note that
the Status of default Users cannot be set to invalid."
::= { a3sysPasswordEntry 1 }
a3sysUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An ASCII string for the User Name. Empty strings are
not allowed. The index column for the User Table. There
are two default users defined, 'root' and 'user'."
::= { a3sysPasswordEntry 2 }
a3sysUserLevel OBJECT-TYPE
SYNTAX INTEGER {
monitor(1),
secureMonitor(2),
manager(3),
specialist(4),
security(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User Access Level defining the scope of management allowed
for this user. Note that the access level of default Users
cannot be changed."
::= { a3sysPasswordEntry 3 }
a3sysOldPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current password."
::= { a3sysPasswordEntry 4 }
a3sysNewPassword OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The new password."
::= { a3sysPasswordEntry 5 }
a3sysSnmpPasswordCtl OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates whether this system's passwords
can be changed via snmp."
::= { a3ComAccCtl 9 }
--
-- The Misc System Group
--
a3sysNetMapTime OBJECT-TYPE
SYNTAX INTEGER (0..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of seconds between broadcasts of the
system's address on the attached network. This
only applies to 3Com's NETMap protocol. If this
object is set to 0, the broadcasting of the system's
address is disabled."
DEFVAL { 0 }
::= { a3ComSysMisc 1 }
a3sysUIBinary OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If on, the system is allowed to negotiate for
binary transmission when a Telnet connection is
made."
DEFVAL { off }
::= { a3ComSysMisc 2 }
a3sysChangeTimestamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains the value of sysUpTime
when the most recent change was made to this
system, either via the Console, TELNET, or
through SNMP."
::= { a3ComSysMisc 3 }
a3sysCpuUtil OBJECT-TYPE
SYNTAX INTEGER (0..100)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object provides a measure of the
current utilization of the CPU on this
system."
::= { a3ComSysMisc 4 }
a3sysCpuBrdMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The system's MAC address. For those devices
whose CPU boards contain a MAC address, this
object provides the value of that address (NB2's).
For those devices whose CPU boards don't contain a
MAC address (NB1's), this provides the MAC address
of the first interface."
::= { a3ComSysMisc 5 }
a3sysExpMacAddr OBJECT-TYPE
SYNTAX MacAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies the MAC address to which the @m
symbol is expanded when doing file copies."
::= { a3ComSysMisc 6 }
a3sysVportTimestamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This specifies the value of sysUpTime when the last
virtual port was added or deleted. This object should
be used to determine if and when the set of virtual ports
supported by this system has changed."
::= { a3ComSysMisc 7 }
a3sysDefDrive OBJECT-TYPE
SYNTAX INTEGER {
driveA (1),
driveB (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the current default drive
for this system."
::= { a3ComSysMisc 8 }
a3sysDefDriveType OBJECT-TYPE
SYNTAX INTEGER {
floppy (1),
flash (2),
unknown (3),
noDrive (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the current default
drive type for this system."
::= { a3ComSysMisc 9 }
a3sysDriveStatus OBJECT-TYPE
SYNTAX INTEGER {
noDrives (1),
driveA (2),
driveB (3),
driveAB (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies which disk drives are supported
by this system. noDrives(1) means no disk drives are
supported. driveA means only drive A is supported.
driveB means only drive B is supported, while driveAB(4)
means both drives A and B are supported."
::= { a3ComSysMisc 10 }
a3sysBogusDhcpSvr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object has the IP address of the last seen
bogus DHCP or BOOTP server."
::= { a3ComSysMisc 11 }
a3sysNb2EepromVers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the version number of the EEPROM
on a NetBuilderII. Various features are dependent on
having the correct version of EEPROM resident on the
NetBuilderII."
::= { a3ComSysMisc 12 }
a3sysX25Conns OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object returns the number of active X25 connections
currently maintained by the NetBuilder."
::= { a3ComSysMisc 13 }
--
--
-- this group controls Firmware related parameters
--
a3sysFwSerBaudCons OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
bps110 (2),
bps300 (3),
bps600 (4),
bps1200 (5),
bps2400 (6),
bps4800 (7),
bps9600 (8),
bps19200 (9),
bps38400 (10),
bps57600 (11)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object sets the baud rate for the
console port, which is located on the CEC
module's connector/LEDC panel."
REFERENCE
"NBII CEC Module Installation Guide: Serial Port
Parameter."
::= { a3ComFW 1 }
a3sysFwSerBaudAux OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
bps110 (2),
bps300 (3),
bps600 (4),
bps1200 (5),
bps2400 (6),
bps4800 (7),
bps9600 (8),
bps19200 (9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object sets the baud rate for the
auxiliary port, which is located on the CEC
module's connector/LEDC panel."
REFERENCE
"NBII CEC Module Installation Guide: Serial Port
Parameter."
::= { a3ComFW 2 }
a3sysFwSelfTest OBJECT-TYPE
SYNTAX INTEGER {
skip (1),
testOnce (2),
other (3),
loop (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter determines how the system handles
self tests when the system is powered on or
reset. The system can be configured to skip its
self tests, run self tests once, or run self
tests continuously (loop)."
REFERENCE
"NBII CEC Module Installation Guide: Self Test
Parameter."
::= { a3ComFW 3 }
--
-- this group controls Booting related Firmware parameters
--
a3sysReBoot OBJECT-TYPE
SYNTAX INTEGER {
other (1),
stdReboot (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object can be used to reboot the system.
If this object is set to stdReboot(2), the
system's action is determined by the value of
a3sysStartUpAction. If that object has the value
monitor(1), the system will go into monitor
mode. If that object has the value userListOnce(2)
or userListForever(3), the system will attempt to
reboot from the sources identified by the User Boot List.
If this object is read, the value, other (1),
will be returned."
REFERENCE
"NBII Ref. Guide, Commands: ReBoot."
::= { a3ComBoot 1 }
a3sysTestBootTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Test Boot Time indicates the number of seconds
after a test reboot the system will automatically
reboot. Upon reboot, the system will start up a timer
initialized to the value of this object. The object
a3sysTestRecoveryTimer contains the real time value of
this timer. The timer will automatically start counting
down after the system comes up. If this timer expires,
the system will automatically reboot using the Primary Boot
Source.
To cancel the timer, the object a3sysTestRecoveryTimer must
be set to zero. This provides a recovery mechanism for a
system under test that loses management connectivity."
::= { a3ComBoot 2 }
a3sysStartUpAction OBJECT-TYPE
SYNTAX INTEGER {
monitor (1),
userListOnce (2),
userListForever (3),
local (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter determines the boot source
when the system is powered on or reset. If
monitor (1) is chosen, the system enters
monitor mode immediately. If userListOnce (2)
is chosen, the system attempts to boot from
primary and secondary sources defined by the
User Boot List. (Specifics about the use of the
secondary boot source are provided by a3sysBootSources.)
This list may identify network boot sources or local
floppy sources, or both.
If userListForever (3) is chosen, the system
will keep trying the sources listed in the
User Boot List until one of them is successful.
If local(4) is chosen, the system will boot from
the local floppy. The name of the file used is
identified by the value of a3sysUblFileName for the
Primary Boot Source."
REFERENCE
"NBII CEC Module Installation Guide: Initial Boot
Type Parameter."
::= { a3ComBoot 3 }
a3sysTestRecoveryTimer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object contains the real time value of the
Test Recovery Timer. When the system is performing
a 'test boot' (ie, a boot when a3sysBootSources equals
testWithPrimaryBackup (3)), the system will start a
countdown timer initialized to the value of a3sysBootTime.
If this timer is allowed to count down to zero, the
system will reboot, this time using the primary boot source
instead of the test boot source. If the timer is disabled, however,
before it counts down (the timer is disabled by setting
the value of this object to zero), the system won't reboot
and will continue to run the test boot source's software.
This timer is part of a comprehensive software update
strategy. See the relevant 3Com manuals for more
details."
::= { a3ComBoot 4 }
a3sysDirectedReBoots OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a counter that tracks the number of times the
system has completed successfully a boot, no matter
how the boot was initiated (power-on, front-panel-button
reset, command line, or exception)."
::= { a3ComBoot 5 }
a3sysExceptionReBoots OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a counter that tracks the number of times
the system has crashed and a reboot sequence is begun
by the exception handler. Note, some type of crashes
are not able to update this counter due to various
hardware lockups. Also note, this counter will be
incremented when a user resets the system from the
command line (RS). This will not be incremented,
however, when the user reboots the system from the
command line (RB)."
::= { a3ComBoot 6 }
a3sysBootDump OBJECT-TYPE
SYNTAX INTEGER {
noDump (1),
monitor (2),
localDevice (3),
userList (4),
network (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This determines whether or not a memory dump
is performed if the system fails due to a
software problem. If noDump (1) is selected,
the system will not attempt to perform a memory
dump. If monitor (2) is selected, the system
goes directly into monitor mode and waits for
further commands. If localDevice (3) is selected,
the system dumps its memory to the local storage
device. Since the memory dump will require several
floppy disks, the system will prompt the user via the
User Interface to change disks. If userList (4) is
selected, the system will upload its memory to the
source specified in the User Boot List.
Only the NetBuilder Remote Office and NetBuilder II support
the network(5) option. If this is set, the parameters in entry
four (dump) of a3sysUserBootListTable identify the destination."
REFERENCE
"NBII CEC Module Installation Guide: Dump Destination
Parameter."
::= { a3ComBoot 7 }
a3sysBootSources OBJECT-TYPE
SYNTAX INTEGER {
primary (1),
primaryAndSecondary (2),
testWithPrimaryBackup (3),
secondary (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter is used to specify how the entries
in this table are used.
If this object is set to primary(1), the system
will use only the primary boot source when
rebooting. (note, this is the entry where
a3sysUblSource = primary(1)).
If this object is set to primaryAndSecondary(2),
the system will attempt to boot first from the
primary boot source, and, if that fails (after
a3sysUblMaxRetries attemps), the system will
try the secondary boot source.
If this object has the value testWithPrimaryBackup(3),
the system, when rebooting, will perform a test boot
using the 'test' boot source. Note, the NetBuilder Remote
Office and NetBuilder II use entry 3 in a3sysUserBootListTable
as the 'test' boot source (a3sysUblSource = test(3)),
while other 3Com routers (NetBuilder Remote, NetBuilder
Remote Control, NetBuilder Local, and NetBuilder Remote
Access) don't support all 4 rows in a3sysUserBootListTable,
and simply use the secondary boot source (a3sysUblSource = secondary(2))
to identify the 'test' boot source.
After booting from the 'test' boot source, if the
Test Recovery Timer (a3sysTestRecoveryTimer) is
allowed to count down to zero, the system will
reboot using the primary boot source. (see the
reference guide for details about test booting).
When in this mode, to prevent the system from rebooting
using the primary boot source, the Test Recovery Timer
(a3sysTestRecoveryTimer) must be set to zero.
Note, this object cannot be set to testWithPrimaryBackup(3)
explicitly. Instead, by setting a3sysTestBootTimer to a
non-zero value, the system will automatically go into
'Test Boot' mode and this object will be given the
value testWithPrimaryBackup(3).
If this object has the value secondary(4), the system will
use only the secondary boot source when rebooting."
::= { a3ComBoot 8 }
a3sysUserBootListTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysUserBootListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table defines a list of boot sources (and for the
NetBuilder Remote Office -- memory dump destinations).
There are two other parameters that dictate how the
contents of this table are used. These parameters
are represented by a3sysStartUpAction and a3sysBootSources.
a3sysStartUpAction specifies what this system does when it
first comes up. If a3sysStartUpAction is set to userListOnce (2),
the system will make a single attempt to use the entries in
this table to identify how it should boot. If a3sysStartUpAction
is set to userListForever (3), the system will make repeated
attempts at using the entries in this table.
If a3sysStartUpAction indicates that the system is to use this
table, the order in which the entries are used is dictated by
a3sysBootSources. If a3sysBootSources has the value primary (1),
the system will attempt to boot only from the source identified by
entry 1 in this table. If a3sysBootSources has the value
primaryAndSecondary(2), the system will attempt to boot first
from the source identified by entry 1, and, if that source fails,
the system will try the source identified by entry 2 (the secondary
source). If a3sysBootSources has the value testWithPrimaryBackup(3),
the system will perform a test boot using the test boot source. Note,
for the NetBuilder Remote Office, this is the third entry (test) in this
table. For the NetBuilder II and the NetBuilder I family( NetBuilder Local,
NetBuilder Remote, NetBuilder RemoteAccess, and NetBuilder RemoteControl),
the test boot source is identified by entry 2 (secondary) in this table.
If the test boot source fails (see the Reference Guide for more details
on test booting), the system will revert back to the source identified
by entry 1 (primary) in this table.
The NetBuilder Remote Office supports a fourth entry in this table,
which identifies where over the network memory is to be dumped in the
case of a system crash. Note, the destination device (a3sysUblDevice)
must be set to network (3), in this case. Also note that many
of the columns in this row will be irrelevant and won't affect
where the memory gets dumped.
Note, all entries in this table apply only to future
boots. They don't necessarily provide information
about previous boots."
REFERENCE
"NBII CEC Module Installation Guide: User Boot List
Parameter."
::= { a3ComBoot 9 }
a3sysUserBootListEntry OBJECT-TYPE
SYNTAX A3sysUserBootListEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table contains a single boot source."
INDEX { a3sysUblSource }
::= { a3sysUserBootListTable 1 }
A3sysUserBootListEntry ::=
SEQUENCE {
a3sysUblSource INTEGER,
a3sysUblDevice INTEGER,
a3sysUblFileName DisplayString,
a3sysUblNetFile DisplayString,
a3sysUblSlot INTEGER,
a3sysUblInterface INTEGER,
a3sysUblMaxRetries INTEGER,
a3sysUblConfigFileDevice INTEGER,
a3sysUblConfigFilePath DisplayString,
a3sysUblConfigProt INTEGER,
a3sysUblConfigUserName DisplayString (SIZE(0..20)),
a3sysUblConfigPassword DisplayString (SIZE(0..20)),
a3sysUblConfigAcct DisplayString (SIZE(0..30)),
a3sysUblMacAddress INTEGER,
a3sysUblCanonicalFlag INTEGER,
a3sysUblRemoteProt INTEGER,
a3sysUblBaudRate INTEGER,
a3sysUblClockSource INTEGER,
a3sysUblConnectorType INTEGER,
a3sysUblWanAddress DisplayString (SIZE(0..80)),
a3sysUblClientIpAddr IpAddress,
a3sysUblServerIpAddr IpAddress,
a3sysUblGwIpAddr IpAddress,
a3sysUblConfigFileIpAddr IpAddress,
a3sysUblIpMask IpAddress,
a3sysUblAddressDiscovery INTEGER,
a3sysUblPassword DisplayString
}
a3sysUblSource OBJECT-TYPE
SYNTAX INTEGER {
primary (1),
secondary (2),
test (3),
dump (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies the entry number in this table.
Currently, the table is limited to two entries.
The first entry is labelled primary(1), the next
has the label secondary(2).
The NetBuilder RemoteOffice and NetBuilder II (as of
sw version 8.0) supports two additional entries.
Entry three (test) identifies a separate
boot block which is used when doing a test boot.
Entry four (dump) identifies where memory is to
be dumped. Note, only a subset of the columns in
this entry are relevant. Specifically, a3sysUblDevice
must have the value network(3) (ie, memory dumps are
preformed only over the network by the NBRO)."
REFERENCE
"NBII CEC Module Installation Guide: User Boot List"
::= { a3sysUserBootListEntry 1 }
a3sysUblDevice OBJECT-TYPE
SYNTAX INTEGER {
localMediaA (1),
localMediaB (2),
network (3),
monitor (4),
other (5),
auto (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object identifies the source from which the
system attempts to boot. If this object is set to
localMediaA(1), the system will attempt to boot from
drive A of the local storage media (A is the flash drive
for those systems with both flash and floppy drives),
using the filename identified by a3sysUblFileName.
If this is set to localMediaB(2), the system will
boot from drive B.
If this object is set to network (3), the system will
attempt to boot from a BOOTP/TFTP server attached to
the network. The network interface that is used in the
booting is identified by both a3sysUblSlot and
a3sysUblInterface.
The name of the boot file on the remote system is
identified by a3sysUblFileName.
monitor(4) is no longer supported.
If this object has the value other(5), nothing has
been specified."
REFERENCE
"NBII CEC Module Installation Guide: User Boot List:
Boot Source Parameter."
::= { a3sysUserBootListEntry 2 }
a3sysUblFileName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the path and name of the boot
file. For example, to specify the file boot.29k in
the root directory, this object should
have the value 'boot.29k'"
REFERENCE
"NBII CEC Module Installation Guide: User Boot List:
Boot Filename Parameter."
::= { a3sysUserBootListEntry 3 }
a3sysUblNetFile OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS deprecated
DESCRIPTION
"This object has been deprecated. (use a3sysUblFileName
regardless of whether it's local or remote)."
REFERENCE
"NBII CEC Module Installation Guide: User Boot List:
Network Boot String Parameter."
::= { a3sysUserBootListEntry 4 }
a3sysUblSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the physical slot where the IO module
from which the system will be booting is installed.
This only applies when a3sysUblDevice is set to
network(2)"
REFERENCE
"NBII CEC Module Installation Guide: User Boot List:
Boot Source Parameter."
::= { a3sysUserBootListEntry 5 }
a3sysUblInterface OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
interfaceA (2),
interfaceB (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the physical port on the IO
module (installed in the slot identified by a3sysUblSlot)
that the system will be booting from. This only applies
when a3sysUblDevice is set to network(2). If there
is only one connector in the module, this object should
have the value: interfaceA(2)."
REFERENCE
"NBII CEC Module Installation Guide: User Boot List:
Boot Source Parameter."
DEFVAL { interfaceA }
::= { a3sysUserBootListEntry 6 }
a3sysUblMaxRetries OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object determines the number of times the
system will try to boot from the source identified
by this table entry before going to the next entry."
REFERENCE
"NBII CEC Module Installation Guide: User Boot List:
Maximum Retries Parameter."
::= { a3sysUserBootListEntry 7 }
a3sysUblConfigFileDevice OBJECT-TYPE
SYNTAX INTEGER {
bootDevice (1),
local (2),
network (3),
other (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the device used to access the
configuration files needed by this system. If
this object has the value bootDevice(1), the
system will look for its configuration files on
the same device as its boot files. This device is
specified by a3sysUblDevice. If this object has
the value network(3), the system will look for
its configuration files on the device specified
by a3sysUblConfigIpAddr. If this object has the
value local(2), the system will look for its
configuration files on the local storage media.
If this object has the value other(4), nothing
has been specified.
In all the cases listed above, the path for the
configuration files is specified by
a3sysUblConfigFilePath."
::= { a3sysUserBootListEntry 8 }
a3sysUblConfigFilePath OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies the path to the configuration
files needed by this system."
::= { a3sysUserBootListEntry 9 }
a3sysUblConfigProt OBJECT-TYPE
SYNTAX INTEGER {
fap (1),
ftp (2),
other (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the protocol to use
to get the configuration files if they
are stored across the network. Note, this
applies only if the value of
a3sysUblConfigFileDevice is network(3) or
bootDevice(1). If a3sysUblConfigFileDevice
has the value bootDevice(1), then the
corresponding instance of a3sysUblDevice
must be network(2) for this object to have relevance.
This object has been changed to read-only in
9.0. The only valid value for this object is
ftp(2)."
::= { a3sysUserBootListEntry 10 }
a3sysUblConfigUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object indicates the Username to be
used by the file service protocol identified
the corresponding instance of a3sysUblConfigProt."
::= { a3sysUserBootListEntry 11 }
a3sysUblConfigPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the Password to be used
by the file service protocol identified by
the corresponding instance of a3sysUblConfigProt.
Note, for reasons of security, the value of this
object will be hidden. A string of 4 stars (*)
will be returned in response to any GET or GETNEXT
request."
::= { a3sysUserBootListEntry 12 }
a3sysUblConfigAcct OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..30))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the Account Name used
by the file service protocol.
Note, for reasons of security, the value of this
object will be hidden. A string of 4 stars (*)
will be returned in response to any GET or GETNEXT
request."
::= { a3sysUserBootListEntry 13 }
a3sysUblMacAddress OBJECT-TYPE
SYNTAX INTEGER {
cpu-module (1),
io-module (2),
other (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The MAC address to be used for booting over the
network. This can be configured to use either the
MAC address assigned to the CPU module or the MAC
address assigned to the I/O module over which the boot
is being performed."
REFERENCE
"NBII CEC Module Installation Guide: System IP Addresses:
Boot MAC Address Parameter."
::= { a3sysUserBootListEntry 14 }
a3sysUblCanonicalFlag OBJECT-TYPE
SYNTAX INTEGER {
other (1),
canonical (2),
nonCanonical (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This controls the format of addresses within
ARP packets sent by this system."
::= { a3sysUserBootListEntry 15 }
a3sysUblRemoteProt OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
ppp (2),
frameRelay (3),
auto (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies which serial link
protocol to use if a3sysUblSlot identifies
a slot with a High Speed Serial board.
If this is set to auto (4), the system
will try all supported protocols until
the serial line is active.
If there is a different kind of board in that
slot, the value of this object is ignored."
::= { a3sysUserBootListEntry 16 }
a3sysUblBaudRate OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
bps9600 (2),
kbps19 (3),
kbps38 (4),
kbps56 (5),
kbps64 (6),
kbps128 (7),
kbps256 (8),
kbps448 (9),
kbps1536 (10),
kbps2048 (11),
mbps4 (12),
mbps16 (13)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies the serial line or
Token Ring baud rate. For all other types
of ports, this object will be ignored."
::= { a3sysUserBootListEntry 17 }
a3sysUblClockSource OBJECT-TYPE
SYNTAX INTEGER {
internal (1),
external (2),
unknown (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies whether to use an internal
or external clock source. This applies only
to High Speed Serial ports."
::= { a3sysUserBootListEntry 18 }
a3sysUblConnectorType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
rs232 (2),
v35 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies the serial line
connector type."
::= { a3sysUserBootListEntry 19 }
a3sysUblWanAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies a string to initiate a
WAN connection. The specified string required
is interface and protocol specific. The maximum
string length is 80 bytes. Note, this applies
only to High Speed Serial ports."
::= { a3sysUserBootListEntry 20 }
a3sysUblClientIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Address of this system used in packets
when booting over the network."
REFERENCE
"NBII CEC Module Installation Guide: System IP Addresses:
Client IP address Parameter."
::= { a3sysUserBootListEntry 21 }
a3sysUblServerIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the Boot Server."
REFERENCE
"NBII CEC Module Installation Guide: System IP Addresses:
Server IP Address Parameter."
::= { a3sysUserBootListEntry 22 }
a3sysUblGwIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the gateway that will forward
packets to the Boot Server."
REFERENCE
"NBII CEC Module Installation Guide: System IP Addresses:
Gateway IP Address Parameter."
::= { a3sysUserBootListEntry 23 }
a3sysUblConfigFileIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the configuration files Server,
if needed."
REFERENCE
"NBII CEC Module Installation Guide: System IP Addresses:
FAP Server IP Address Parameter."
::= { a3sysUserBootListEntry 24 }
a3sysUblIpMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The mask to be applied to the addresses specified
above."
::= { a3sysUserBootListEntry 25 }
a3sysUblAddressDiscovery OBJECT-TYPE
SYNTAX INTEGER {
other (1),
bootp (2),
configAddr (3),
bootpRarp (4),
rarp (5),
rarpBootp (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the address discovery protocol
to use for booting from the network. If configAddr(3)
is specified, then the configured addresses are
used. If nothing has been specified, other(1) is
returned."
::= { a3sysUserBootListEntry 26 }
a3sysUblPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is needed when booting over a port that
uses a protocol that requires a password, e.g,
PPP."
::= { a3sysUserBootListEntry 27 }
--
-- The next table controls the booting of the Intelligent IO
-- Boards. As of 8.0, IIO boards must boot from either
-- local storage or from the location where the config files
-- are stored (which may be from local storage).
--
a3sysIioBootTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysIioBootEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table specifies where each IIO card
obtains its boot image."
::= { a3ComBoot 10 }
a3sysIioBootEntry OBJECT-TYPE
SYNTAX A3sysIioBootEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table corresponds to a
specific slot in the NetBuilder chassis. If
an IIO board is in that slot, that entry
determines where that IIO board obtains its
boot image."
INDEX { a3sysIioBootSlot }
::= { a3sysIioBootTable 1 }
A3sysIioBootEntry ::=
SEQUENCE {
a3sysIioBootSlot INTEGER,
a3sysIioBootFileName DisplayString,
a3sysIioBootState INTEGER,
a3sysIioBootTime TimeTicks,
a3sysIioBootImage OBJECT IDENTIFIER
}
a3sysIioBootSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the slot into which
the IIO board corresponding to this entry
is placed."
::= { a3sysIioBootEntry 1 }
a3sysIioBootFileName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies the path and name of the
IIO board's boot image. If the value of
this object specifies a drive, the path is assumed
to start from root. If the value of this object does
not specify a drive number, this object specifies the
path starting from the config file directory specified by
a3sysUblConfigFilePath. In this case, the value of this
object must not begin with a slash '/'."
::= { a3sysIioBootEntry 2 }
a3sysIioBootState OBJECT-TYPE
SYNTAX INTEGER {
empty (1), -- card not available for use
up (2), -- card is up and running
booting (3), -- card is in the process of booting
recovering (4), -- card is recovering from a failed boot
dumping (5), -- while recovering, card is dumping image
halted (6), -- card has halted after failed boot
selfTestFail (7), -- self test failed
error (8) -- card's in unrecoverable errored state
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object provides the current state of the IIO
card installed in this slot. If there is no IIO
card in the slot, this object will have the value
empty(1). If the card is up and running, this object
will have the value up(2). If the card is booting,
this object will have the value booting(3). If the
boot has failed, and the card is in the process of
recovering from the failed boot, this object will have
the value recovering(4). If in the process of
recovering, the IIO dumps its image, this object will
have the value dumping(5). Note that this is simply
a sub-state within the more general recovering state.
If after recovering, the IIO card goes into a halted
state, this object will have the value halted(6). If
the IIO card gets into an unrecoverable state, this
object will have the value error(8)."
::= { a3sysIioBootEntry 3 }
a3sysIioBootTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when the IIO board last
went into the UP state."
::= { a3sysIioBootEntry 4 }
a3sysIioBootImage OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The OID assigned to this version of Iio Software."
::= { a3sysIioBootEntry 5 }
--
-- The Last Boot Group. This group contains information about the
-- most recent boot of the system
--
a3sysLastBootSource OBJECT-TYPE
SYNTAX INTEGER {
primary (1),
secondary (2),
monitor (3),
test (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the source from which the
system last booted.
The specifics of the boot source can be found
from the corresponding User Boot List entry."
REFERENCE
"NBII CEC Module Installation Guide: User Boot List:
Boot Source Parameter."
::= { a3ComLastBoot 1 }
a3sysLastBootError OBJECT-TYPE
SYNTAX INTEGER {
none (1), -- there have been no known
-- failures
unknownLocalAddress (2),
unknownServerAddress (3),
noServerResponse (4),
fileTransferFailed (5),
imageNotFound (6),
imageInvalid (7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the reason for the
most recent boot failure."
::= { a3ComLastBoot 2 }
a3sysLastBootDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time as reflected by the system
clock at the time the system last rebooted.
The date has the format yy/mm/dd hh:mm[:ss]."
::= { a3ComLastBoot 3 }
a3sysLbConfigFileIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the configuration file server
used during the most recent boot. Note, even
if the configuration files were obtained locally,
an address may have been configured. This is the
address used when performing all ftp PUT and GET
operations."
::= { a3ComLastBoot 4 }
a3sysLbGwIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address of the gateway that was used to
forward packets to the boot server or configuration file
server during the last boot."
::= { a3ComLastBoot 5 }
a3sysLbIpMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP subnet mask configured during the last boot."
::= { a3ComLastBoot 6 }
a3sysLbConfigDevice OBJECT-TYPE
SYNTAX INTEGER {
bootDevice (1),
local (2),
network (3),
other (4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The config file device used during the last boot."
::= { a3ComLastBoot 7 }
a3sysLbConfigFilePath OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The config file path used during the last boot."
::= { a3ComLastBoot 8 }
a3sysLbConfigUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If the config files were obtained from a file server
during the last boot, this object contains the user
name used during the ftp transfer of those files."
::= { a3ComLastBoot 9 }
--
-- The File Management group
--
a3sysFmOperation OBJECT-TYPE
SYNTAX INTEGER {
other (1),
copy (2),
do (3),
delete (4),
rename (5),
directory (6),
format (7),
copySystem (8),
checksum (9),
abortCopy (10),
makeDir (11),
rmDir (12),
getFileInfo (13),
ftpGet (14),
ftpPut (15),
cleanFlash (16)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is used to initiate a file
management operation. When set to copy(2), the
system will get the file from the Source device
(identified by a3sysFmSourceIpAddr and
a3sysFmSourceFile) and copy it to the
Target device (identified by a3sysFmTargetIpAddr
and a3sysFmTargetFile). Note, both the
Source and Target devices cannot be
remote systems. At least one must be
the local system.
All information about the file
and the server is taken from the values
of the other objects in this group. To
avoid unnecessary errors, the relevant objects
in this group should be examined and
their values validated before setting this object
to copy(2).
Currently, the do(3) enumeration is not supported.
If this object is set to delete(4), the system
will delete a single file on the local storage
device. The file is identified by a3sysFmTargetFile.
For software release 6.2, the rename(5) enumeration
is not supported. This is supported, however, by
release 7.0.
If this object is directory(6), the system will list
the file in the directory identified by a3sysFmTargetFile.
The resulting list can be obtained by examining
a3sysDfTable.
For software release 6.2, enumerations 7 through 9
are not supported. Enumeration 7 and 9 are supported
by release 7.0.
If this object is set to abortCopy(10), the
system will abort any file copy process in
progress.
If this object is set to makeDir(11), the system
will create a directory off the root directory. The
name of this directory is specified by a3sysFmTargetFile.
If this object is set to rmDir(12), the system will
remove the directory identified by a3sysFmTargetFile.
If this object is set to getFileInfo(13), the system
will retrieve information about the file identified
by a3sysFmTargetFile and return that information via
the a3ComFileInfo group. (ie, examine the contents
of that group after this object is set to getFileInfo(13)).
If this object is set to ftpGet(14), the system
will retrieve the file identified by a3sysFmSourceFile.
It will retrieve the file from the device from
which the configuration files were originally obtained.
That device can be identified by
a3sysLbConfigFileIpAddr. Note, even if the config
files were obtained locally, a valid IP address may
have been configured. That is the device used for
future ftp operations.
If a path is not specified, the file will be taken
from the configuration file directory. The config
file directory cay be identified by
a3sysLbConfigFilePath. If a relative
path is specified, and the configuration files were
originally obtained (ie, at last boot) from the
network, the path is interpreted relative to the
configuration file directory. If a relative path
is specified and the configuration files were originally
obtained locally, the path is interpreted relative
to the login directory. Absolute paths are allowed.
Once obtained, the file will be placed in the location
identified by a3sysFmTargetFile. Note, this must be
on one of the local storage devices.
If this object is set to ftpPut(15), the system
will place the file identified by a3sysFmSourceFile
and place it on the device from which the config
files were obtained originally. The path and
filename of the placed file is identified by
a3sysFmTargetFile. As with ftpGet(14), if a relative
path is specified, and the configuration files were
originally obtained from the network, the path is
interpreted relative to the configuration file
directory. If a relative path is specified and the
configuration files were originally obtained locally,
the path is interpreted relative to the login
directory. Absolut paths are allowed. Note, the
source file must be on one of the local storage devices.
If this object is read, other(1) will be
returned."
::= { a3ComFileMgmt 1 }
a3sysFmSourceIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies the IP address of
the Source device from which files are
obtained.
If this is set to zero's, the local storage
device is assumed."
::= { a3ComFileMgmt 2 }
a3sysFmSourceFile OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the path and name of
a source file. For example, if the
action specified by a3sysFmOperation is
copy(2) or rename(5), this identifies the
path and name of the file to be copied or
renamed.
If there is no leading path string, the
source file will be accessed from the root
directory. For devices with multiple disk
drives, the drive will be identified by appending
a prefix to the path. For example, a:/path/name"
::= { a3ComFileMgmt 3 }
a3sysFmTargetIpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies the IP address of
the target device to which files are
copied, renamed, etc."
::= { a3ComFileMgmt 4 }
a3sysFmTargetFile OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This specifies the path and name of
the target file on the target system.
(The filename may contain the string '@M'
which will be expanded to the system MAC address.
Alternatively, the filename may contain
the string '@m' which will be expanded to
the last six characters of the system MAC address.
This provides a mechanism for a remote system to
generate system specific filenames automatically.)
If there is no leading path string, the
file will be accessed from the root directory.
For devices with multiple disk drives, the drive
will be identified by appending a prefix to the path.
For example, a:/path/name.
If the action specified by a3sysFmOperation is copy(2),
this identifies where, on the target system (identified
by a3sysFmTargetIpAddr) the file is to be placed and the
name to give it.
If the action specified by a3sysFmOperation is
delete(4), this identifies the path and
name of the local file which is to be
deleted.
If the action specified by a3sysFmOperation is
directory(6), this identifies the full path
of the directory that is to be listed."
::= { a3ComFileMgmt 5 }
a3sysFmStatus OBJECT-TYPE
SYNTAX INTEGER {
inactive (1),
inProgress (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies the current status
of the file management operation. This applies
to the following operations: copy(2),
and directory(6). If there
is an operation in progress, this object
will have the value inProgress(2). Otherwise
inactive(1) will be returned."
::= { a3ComFileMgmt 6 }
a3sysFmTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This specifies the value of sysUpTime when
the most recent file management operation was
initiated."
::= { a3ComFileMgmt 7 }
a3sysFmError OBJECT-TYPE
SYNTAX INTEGER {
none (1), -- no operations since initialization
successful (2), -- the most recent operation was
-- successful
inProgress (3), -- another operation was already in
-- progress
badSourceAddr (4), -- the Source IP Address is invalid
badSourceFile (5), -- the Source file is invalid
badTargetAddr (6), -- the Target IP Address is invalid
badTargetFile (7), -- the Target file is invalid
noResponse (8), -- no response from the server
noFile (9), -- the file or dir. could not be found
noSpace (10), -- no space on destination system
noPermission (11), -- destination device is write protected
writeError (12), -- error encountered when writing
timeout (13), -- timeout during transfer
badChecksum (14), -- invalid file checksum computed
badOperation (15), -- invalid file operation
aborted (16), -- operation aborted by user
other (17), -- an error not listed here
badDefaultDrv (18), -- the Default Drive is not Local
badTargetPort (19) -- the Target Udp/Tcp port is unreachable
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the results of the
most recent attempt at a file operation. If no
file operations have been attempted since the
system was initialized, this object will have the
value none(1).
If the last operation was successful, this object
will have the value successful(2).
If the last operation could not be initiated
because there was another operation in progress,
this object will have the value inProgress (3).
If the source IP Address is invalid, this object
will have the value badSourceAddr(4).
If the source file name contains a syntax error,
this object will have the value badSourceFile(5).
If the target IP Address is invalid, this object
will have the value badTargetAddr(6).
If there was a syntax error in the identification
of the target file (a3sysFmTargetFile), this
object will have the value badTargetFile(7).
If the remote server does not respond, this
object will have the value noResponse(8).
If either the source file or target file could
not be found, this object will have the value
noFile(9).
If there is no space on the destination system
this object will have the value noSpace(10).
If the destination file location is write protected,
this object will have the value noPermission(11).
If there is an error encountered while
writing the file to its destination, this object
will have the value writeError(12).
If the transfer took too much time and exceeded
its limits, this object will have the value timeout(13).
If the verify operation failed, this object will have
the value badChecksum(14).
If the operation requested is not supported by this
platform or software version, this object will have
the value badOperation(15).
If the opereration was aborted by a user, this object
will have the value aborted(16).
If no drive is indicated in either the source or target
files, and the default drive is not local (this will be
the case when the system obtained its config files over
the network the last time it booted), this object will
have the value badDefaultDrv(18).
This object will have the value other(17) if an error
occured that is not listed here."
::= { a3ComFileMgmt 8 }
--
-- Disk File List Group
--
a3sysDfTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the value of sysUpTime when
the list of files on the system disk was last updated.
This list is updated by setting a3sysFmOperation to
directory(6)."
::= { a3ComFileList 1 }
a3sysDfPath OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object identifies the directory path under which
the files listed in a3sysDfTable were obtained. Where
necessary, this object also identifies the disk drive
where the files are stored."
::= { a3ComFileList 2 }
a3sysDfTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysDfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains a listing of all the files in a
specific directory on one of the systems disks. The
directory and disk are identified by a3sysDfPath.
Each entry in this table contains information about
a single file."
::= { a3ComFileList 3 }
a3sysDfEntry OBJECT-TYPE
SYNTAX A3sysDfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table describes a single disk file."
INDEX { a3sysDfName }
::= { a3sysDfTable 1 }
A3sysDfEntry ::=
SEQUENCE {
a3sysDfName DisplayString,
a3sysDfDir INTEGER
}
a3sysDfName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This contains the name of a single file on the disk."
::= { a3sysDfEntry 1 }
a3sysDfDir OBJECT-TYPE
SYNTAX INTEGER {
file (1),
directory (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This specifies whether the file identified by the
corresponding instance of a3sysDfName is a regular
file or a directory."
::= { a3sysDfEntry 2 }
a3ComDfTotalSpace OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total size (in bytes) of the drive identified by
a3sysDfPath"
::= { a3ComFileList 4 }
a3ComDfAvailableSpace OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The available space (in bytes) of the drive identified
by a3sysDfPath."
::= { a3ComFileList 5 }
--
-- FM Cksum Group
--
-- This group provides information related to the checksums associated with
-- files kept by the system
--
a3sysFmCksum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the results of a ccitt crc16
cyclic redundancy check performed on the file specified
by a3sysTargetFile. The value of a3sysTargetFile at
the time this crc was performed is provided by a3sysFmCksumFile."
::= { a3ComFmCksum 1 }
a3sysFmCksumFile OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the file upon which the last ccitt crc16
cyclic redundancy check was performed. The results of this operation
are specified by a3sysFmCksum."
::= { a3ComFmCksum 2 }
a3sysFmCksumTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the value of sysUpTime when the last ccitt crc16
cyclic redundancy check was performed. The results of this operation
are specified by a3sysFmCksum."
::= { a3ComFmCksum 3 }
--
-- FM General Info Group
--
-- This group provides general information related to a specific
-- file kept by the system. In order to get infomation about
-- a specific file, set a3sysFmTargetFile to the desired file,
-- and set a3sysFmOperation to 13. After a3sysFmStatus returns
-- to inactive, and assuming no errors have been encountered (check
-- the value of a3sysFmError, the objects in this group will provide
-- information about the desired file.
--
a3sysFiName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the name of the file to which
the rest of this group refers."
::= { a3ComFileInfo 1 }
a3sysFiDate OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the date when the file (specified by
a3sysFiName was last updated. The format of the date is
yy/mm/dd hh:min:sec."
::= { a3ComFileInfo 2 }
a3sysFiTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the value of sysUpTime when this group of
objects was last updated. To update this group, set a3sysFmTargetFile
to the desired file, and set a3sysFmOperation to getFileInfo(13)."
::= { a3ComFileInfo 3 }
a3sysFmSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the size of the file (specified by a3sysFiName)
in bytes."
::= { a3ComFileInfo 4 }
--
-- This next section specifies the behavior of this system in the event
-- of a crash.
--
--
-- The first table in this group specifies how this system recovers
-- if a specific IIO board or the CEC board crashes.
--
a3sysIioRecoveryTable OBJECT-TYPE
SYNTAX SEQUENCE OF A3sysIioRecoveryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table specifies the recovery procedure
for each Intelligent IO board in the system.
This also specifies the recovery procedure
for the CEC card. Note, the eeprom version
must be 5 or greater for this table to operate
properly."
::= { a3ComRecovery 1 }
a3sysIioRecoveryEntry OBJECT-TYPE
SYNTAX A3sysIioRecoveryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table corresponds to a
specific slot in the NetBuilder chassis. If
an IIO board is in that slot, that entry
determines the action taken by that IIO
board in the event it crashes. There is also
an entry in this table for the CEC board."
INDEX { a3sysIioRecoverySlot }
::= { a3sysIioRecoveryTable 1 }
A3sysIioRecoveryEntry ::=
SEQUENCE {
a3sysIioRecoverySlot INTEGER,
a3sysIioRecoveryProcedure INTEGER,
a3sysIioRecoverySelect INTEGER
}
a3sysIioRecoverySlot OBJECT-TYPE
SYNTAX INTEGER (0..8)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object specifies the slot into which
the IIO (or CEC) board corresponding to this
entry is placed."
::= { a3sysIioRecoveryEntry 1 }
a3sysIioRecoveryProcedure OBJECT-TYPE
SYNTAX INTEGER {
halt (1),
haltSystem (2),
reboot (3),
rebootSystem (4),
dumpAndReboot (5),
selectiveDumpAndReboot (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The value of this object determines the
action taken if the IIO (or CEC) crashes.
If the value of this object is
selectiveDumpAndReboot (5), the value of
a3sysIioRecoverySelect determines which
IIO (or CEC) boards will dump and reboot
in the event that this IIO board crashes."
::= { a3sysIioRecoveryEntry 2 }
a3sysIioRecoverySelect OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object specifies the IIO or CEC
boards that will dump and reboot in the event
this IIO or CEC board crashes. This
object is relevant only if the value of
a3sysIioRecoveryProcedure is
selectiveDumpAndReboot (6).
The boards are specified by their slot. Each
slot is represented by a single bit in the
value of this object. If that bit is set (to
1), then that board will dump and reboot.
Slot 0 is used to identify the CEC board, and
corresponds to the least significant bit in
this object.
Slot 1 is used to identify the IIO board in
that slot and corresponds to the next
significant bit in this object. The identification
of all other boards follows this convention."
::= { a3sysIioRecoveryEntry 3 }
--
-- Trap Defines
--
a3BogusDhcpSvr TRAP-TYPE
ENTERPRISE a3Com
VARIABLES { a3sysBogusDhcpSvr }
DESCRIPTION "A a3BogusDhcpSvr trap signifies that an unauthorized
DHCP or BOOTP server has been detected on the network."
::= 100
END