<?php
/**
* Observium
*
* This file is part of Observium.
*
* @package observium
* @subpackage discovery
* @copyright (C) 2006-2013 Adam Armstrong, (C) 2013-2019 Observium Limited
*
*/
echo(" HPN-ICF-ENTITY-EXT-MIB ");
$oids = array('hpnicfEntityExtStateTable', 'entPhysicalName');
$entity_array = array();
foreach ($oids as $oid)
{
$entity_array = snmpwalk_cache_oid($device, $oid, $entity_array, 'ENTITY-MIB:HPN-ICF-ENTITY-EXT-MIB');
}
foreach ($entity_array as $index => $entry)
{
// HPN-ICF-ENTITY-EXT-MIB::hpnicfEntityExtTemperature.8 = INTEGER: 50
// HPN-ICF-ENTITY-EXT-MIB::hpnicfEntityExtTemperatureThreshold.8 = INTEGER: 85
// HPN-ICF-ENTITY-EXT-MIB::hpnicfEntityExtCriticalTemperatureThreshold.8 = INTEGER: 95
// HPN-ICF-ENTITY-EXT-MIB::hpnicfEntityExtLowerTemperatureThreshold.8 = INTEGER: -30
// HPN-ICF-ENTITY-EXT-MIB::hpnicfEntityExtShutdownTemperatureThreshold.8 = INTEGER: 65535
$options = array('entPhysicalIndex' => $index);
if ($entry['hpnicfEntityExtTemperature'] != 65535 &&
$entry['hpnicfEntityExtTemperatureThreshold'] != 65535 &&
$entry['hpnicfEntityExtLowerTemperatureThreshold'] != 65535)
{
$options['limit_low'] = $entry['hpnicfEntityExtLowerTemperatureThreshold'];
$options['limit_high_warn'] = $entry['hpnicfEntityExtTemperatureThreshold'];
if (($entry['hpnicfEntityExtCriticalTemperatureThreshold'] != 65535 && $entry['hpnicfEntityExtCriticalTemperatureThreshold'] >= $entry['hpnicfEntityExtTemperatureThreshold']))
{
$options['limit_high'] = $entry['hpnicfEntityExtCriticalTemperatureThreshold'];
} else {
$options['limit_high'] = $entry['hpnicfEntityExtTemperatureThreshold'] + 10;
}
$value = $entry['hpnicfEntityExtTemperature'];
$oid = ".1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.12.$index";
$descr = $entry['entPhysicalName'];
$oid_name = 'hpnicfEntityExtTemperature';
$options['rename_rrd'] = "hh3c-entity-ext-mib-hpnicfEntityExtTemperature.$index";
discover_sensor_ng($device,'temperature', $mib, $oid_name, $oid, $index, NULL, $descr, 1, $value, $options);
}
// HPN-ICF-ENTITY-EXT-MIB::hpnicfEntityExtVoltage.1 = INTEGER: 0
// HPN-ICF-ENTITY-EXT-MIB::hpnicfEntityExtVoltageLowThreshold.1 = INTEGER: 0
// HPN-ICF-ENTITY-EXT-MIB::hpnicfEntityExtVoltageHighThreshold.1 = INTEGER: 0
if ($entry['hpnicfEntityExtVoltage'] != 0)
{
$options['limit_low'] = $entry['hpnicfEntityExtVoltageLowThreshold'];
$options['limit_high'] = $entry['hpnicfEntityExtVoltageHighThreshold'];
$oid_name = 'hpnicfEntityExtVoltage';
$value = $entry['hpnicfEntityExtVoltage'];
$oid = ".1.3.6.1.4.1.11.2.14.11.15.2.6.1.1.1.1.14.$index";
$descr = $entry['entPhysicalName'];
// FIXME scale is unknown, and not documented in the MIB; probably not 1?? My V1910 doesn't have voltage sensors.
$options['rename_rrd'] = "hh3c-entity-ext-mib-hpnicfEntityExtVoltage.$index";
discover_sensor_ng($device,'voltage', $mib, $oid_name, $oid, $index, NULL, $descr, 1, $value, $options);
}
// [hpnicfEntityExtErrorStatus] => normal
}
unset($oids, $index, $value, $descr, $options);
// EOF