IEEE8023-MAU-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Counter32, Integer32, Counter64, Unsigned32,
|
|
OBJECT-TYPE, MODULE-IDENTITY, NOTIFICATION-TYPE, org
|
|
FROM SNMPv2-SMI -- RFC 2578
|
|
TruthValue, AutonomousType
|
|
FROM SNMPv2-TC -- RFC 2579
|
|
OBJECT-GROUP, MODULE-COMPLIANCE, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF -- RFC 2580
|
|
InterfaceIndex
|
|
FROM IF-MIB -- RFC 2863
|
|
IANAifMauTypeListBits, IANAifMauMediaAvailable,
|
|
IANAifMauAutoNegCapBits, IANAifJackType
|
|
FROM IANA-MAU-MIB
|
|
-- http://www.iana.org/assignments/ianamau-mib
|
|
;
|
|
|
|
ieee8023mauMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201304110000Z" -- April 11, 2013
|
|
ORGANIZATION
|
|
"IEEE 802.3 working group"
|
|
CONTACT-INFO
|
|
"WG-URL: http://www.ieee802.org/3/index.html
|
|
WG-EMail: STDS-802-3-MIB@LISTSERV.IEEE.ORG
|
|
|
|
Contact: Howard Frazier
|
|
Postal: 3151 Zanker Road
|
|
San Jose, CA 95134
|
|
USA
|
|
Tel: +1.408.922.8164
|
|
E-mail: hfrazier@broadcom.com"
|
|
DESCRIPTION
|
|
"Management information for 802.3 MAUs."
|
|
|
|
REVISION "201304110000Z" -- April 11, 2013
|
|
DESCRIPTION
|
|
"Revision, based on an earlier version in IEEE Std 802.3.1-2011."
|
|
|
|
REVISION "201102020000Z" -- February 2, 2011
|
|
DESCRIPTION
|
|
"Initial version, based on an earlier version published
|
|
as RFC 4836."
|
|
|
|
::= { org ieee(111) standards-association-numbers-series-standards(2)
|
|
lan-man-stds(802) ieee802dot3(3) ieee802dot3dot1mibs(1) 13 }
|
|
|
|
|
|
ieee8023snmpDot3MauMgt OBJECT IDENTIFIER ::= { ieee8023mauMIB 1 }
|
|
|
|
dot3RpMauBasicGroup
|
|
OBJECT IDENTIFIER ::= { ieee8023snmpDot3MauMgt 1 }
|
|
dot3IfMauBasicGroup
|
|
OBJECT IDENTIFIER ::= { ieee8023snmpDot3MauMgt 2 }
|
|
-- The following object is a placeholder
|
|
-- to preserve the arc assignments that follow it.
|
|
dot3PlaceholderGroup
|
|
OBJECT IDENTIFIER ::= { ieee8023snmpDot3MauMgt 3 }
|
|
|
|
-- OIDs under the following branch are reserved for
|
|
-- the IANA-MAU-MIB to assign as MAU type values:
|
|
-- { ieee8023snmpDot3MauMgt 4 }
|
|
|
|
dot3IfMauAutoNegGroup
|
|
OBJECT IDENTIFIER ::= { ieee8023snmpDot3MauMgt 5 }
|
|
|
|
--
|
|
-- The Basic Repeater MAU Table
|
|
--
|
|
|
|
rpMauTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RpMauEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of descriptive and status information
|
|
about the MAU(s) attached to the ports of a
|
|
repeater."
|
|
::= { dot3RpMauBasicGroup 1 }
|
|
|
|
rpMauEntry OBJECT-TYPE
|
|
SYNTAX RpMauEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table, containing information
|
|
about a single MAU."
|
|
INDEX { rpMauGroupIndex,
|
|
rpMauPortIndex,
|
|
rpMauIndex
|
|
}
|
|
::= { rpMauTable 1 }
|
|
|
|
RpMauEntry ::=
|
|
SEQUENCE {
|
|
rpMauGroupIndex Integer32,
|
|
rpMauPortIndex Integer32,
|
|
rpMauIndex Integer32,
|
|
rpMauType AutonomousType,
|
|
rpMauStatus INTEGER,
|
|
rpMauMediaAvailable IANAifMauMediaAvailable,
|
|
rpMauMediaAvailableStateExits Counter32,
|
|
rpMauJabberState INTEGER,
|
|
rpMauJabberingStateEnters Counter32,
|
|
rpMauFalseCarriers Counter32
|
|
}
|
|
|
|
rpMauGroupIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This variable uniquely identifies the group
|
|
containing the port to which the MAU described
|
|
by this entry is connected.
|
|
|
|
Note: In practice, a group will generally be
|
|
a field-replaceable unit (i.e., module, card,
|
|
or board) that can fit in the physical system
|
|
enclosure, and the group number will correspond
|
|
to a number marked on the physical enclosure.
|
|
|
|
The group denoted by a particular value of this
|
|
object is the same as the group denoted by the
|
|
same value of rptrGroupIndex."
|
|
REFERENCE "RFC 2108, rptrGroupIndex."
|
|
::= { rpMauEntry 1 }
|
|
|
|
rpMauPortIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This variable uniquely identifies the repeater
|
|
port within group rpMauGroupIndex to which the
|
|
MAU described by this entry is connected."
|
|
REFERENCE "RFC 2108, rptrPortIndex."
|
|
::= { rpMauEntry 2 }
|
|
|
|
rpMauIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This variable uniquely identifies the MAU
|
|
described by this entry from among other
|
|
MAUs connected to the same port
|
|
(rpMauPortIndex)."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.1, aMAUID."
|
|
::= { rpMauEntry 3 }
|
|
|
|
rpMauType OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the MAU type. Values for
|
|
standard IEEE 802.3 MAU types are defined in the
|
|
IANA maintained IANA-MAU-MIB module, as
|
|
OBJECT-IDENTITIES of dot3MauType.
|
|
If the MAU type is unknown, the object identifier
|
|
zeroDotZero is returned."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.2, aMAUType."
|
|
::= { rpMauEntry 4 }
|
|
|
|
rpMauStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
unknown(2),
|
|
operational(3),
|
|
standby(4),
|
|
shutdown(5),
|
|
reset(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The current state of the MAU. This object may
|
|
be implemented as a read-only object by those
|
|
agents and MAUs that do not implement software
|
|
control of the MAU state. Some agents may not
|
|
support setting the value of this object to some
|
|
of the enumerated values.
|
|
|
|
The value other(1) is returned if the MAU is in
|
|
a state other than one of the states 2 through
|
|
6.
|
|
The value unknown(2) is returned when the MAU's
|
|
true state is unknown; for example, when it is
|
|
being initialized.
|
|
|
|
A MAU in the operational(3) state is fully
|
|
functional; it operates, and passes signals to its
|
|
attached DTE or repeater port in accordance to
|
|
its specification.
|
|
|
|
A MAU in standby(4) state forces DI and CI to
|
|
idle, and the media transmitter to idle or fault,
|
|
if supported. Standby(4) mode only applies to
|
|
link type MAUs. The state of
|
|
rpMauMediaAvailable is unaffected.
|
|
|
|
A MAU in shutdown(5) state assumes the same
|
|
condition on DI, CI, and the media transmitter,
|
|
as though it were powered down or not connected.
|
|
The MAU may return other(1) value for the
|
|
rpMauJabberState and rpMauMediaAvailable objects
|
|
when it is in this state. For an AUI, this
|
|
state will remove power from the AUI.
|
|
|
|
Setting this variable to the value reset(6)
|
|
resets the MAU in the same manner as a
|
|
power-off, power-on cycle of at least one-half
|
|
second would. The agent is not required to
|
|
return the value reset(6).
|
|
|
|
Setting this variable to the value
|
|
operational(3), standby(4), or shutdown(5)
|
|
causes the MAU to assume the respective state,
|
|
except that setting a mixing-type MAU or an AUI
|
|
to standby(4) will cause the MAU to enter the
|
|
shutdown state."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.7, aMAUAdminState,
|
|
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
|
|
acResetMAU."
|
|
::= { rpMauEntry 5 }
|
|
|
|
rpMauMediaAvailable OBJECT-TYPE
|
|
SYNTAX IANAifMauMediaAvailable
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies Media Available state of
|
|
the MAU, complementary to the rpMauStatus. Values
|
|
for the standard IEEE 802.3 Media Available states
|
|
are defined in the IANA maintained IANA-MAU-MIB
|
|
module, as IANAifMauMediaAvailable TC."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.4, aMediaAvailable."
|
|
::= { rpMauEntry 6 }
|
|
|
|
rpMauMediaAvailableStateExits OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of times that
|
|
rpMauMediaAvailable for this MAU instance leaves
|
|
the state available(3).
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management
|
|
system and at other times, as indicated by the
|
|
value of rptrMonitorPortLastChange."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.5, aLoseMediaCounter.
|
|
RFC 2108, rptrMonitorPortLastChange"
|
|
::= { rpMauEntry 7 }
|
|
|
|
rpMauJabberState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
unknown(2),
|
|
noJabber(3),
|
|
jabbering(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The value other(1) is returned if the jabber
|
|
state is not 2, 3, or 4. The agent shall
|
|
return other(1) for MAU type dot3MauTypeAUI.
|
|
|
|
The value unknown(2) is returned when the MAU's
|
|
true state is unknown; for example, when it is
|
|
being initialized.
|
|
|
|
If the MAU is not jabbering the agent returns
|
|
noJabber(3). This is the 'normal' state.
|
|
|
|
If the MAU is in jabber state the agent returns
|
|
the jabbering(4) value."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.6, aJabber.jabberFlag."
|
|
::= { rpMauEntry 8 }
|
|
|
|
rpMauJabberingStateEnters OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of times that
|
|
mauJabberState for this MAU instance enters the
|
|
state jabbering(4). For MAUs of type
|
|
dot3MauTypeAUI, dot3MauType100BaseT4,
|
|
dot3MauType100BaseTX, dot3MauType100BaseFX, and
|
|
all 1000 Mb/s types, this counter will
|
|
indicate zero.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management
|
|
system and at other times, as indicated by the
|
|
value of rptrMonitorPortLastChange."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.6, aJabber.jabberCounter.
|
|
RFC 2108, rptrMonitorPortLastChange"
|
|
::= { rpMauEntry 9 }
|
|
|
|
rpMauFalseCarriers OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of false carrier events
|
|
during IDLE in 100BASE-X links. This counter
|
|
does not increment at the symbol rate. It can
|
|
increment after a valid carrier completion at a
|
|
maximum rate of once per 100 ms until the next
|
|
carrier event.
|
|
|
|
This counter increments only for MAUs of type
|
|
dot3MauType100BaseT4, dot3MauType100BaseTX,
|
|
dot3MauType100BaseFX, and all 1000 Mb/s types.
|
|
|
|
For all other MAU types, this counter will
|
|
indicate zero.
|
|
|
|
The approximate minimum time for rollover of
|
|
this counter is 7.4 hours.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management
|
|
system and at other times, as indicated by the
|
|
value of rptrMonitorPortLastChange."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.10, aFalseCarriers.
|
|
RFC 2108, rptrMonitorPortLastChange"
|
|
::= { rpMauEntry 10 }
|
|
|
|
-- The rpJackTable applies to MAUs attached to repeaters
|
|
-- which have one or more external jacks (connectors).
|
|
rpJackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF RpJackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Information about the external jacks attached
|
|
to MAUs attached to the ports of a repeater."
|
|
::= { dot3RpMauBasicGroup 2 }
|
|
|
|
rpJackEntry OBJECT-TYPE
|
|
SYNTAX RpJackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table, containing information
|
|
about a particular jack."
|
|
INDEX { rpMauGroupIndex,
|
|
rpMauPortIndex,
|
|
rpMauIndex,
|
|
rpJackIndex
|
|
}
|
|
::= { rpJackTable 1 }
|
|
|
|
RpJackEntry ::=
|
|
SEQUENCE {
|
|
rpJackIndex Integer32,
|
|
rpJackType IANAifJackType
|
|
}
|
|
|
|
rpJackIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This variable uniquely identifies the jack
|
|
described by this entry from among other jacks
|
|
attached to the same MAU (rpMauIndex)."
|
|
::= { rpJackEntry 1 }
|
|
|
|
rpJackType OBJECT-TYPE
|
|
SYNTAX IANAifJackType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The jack connector type, as it appears on the
|
|
outside of the system."
|
|
::= { rpJackEntry 2 }
|
|
|
|
--
|
|
-- The Basic Interface MAU Table
|
|
--
|
|
ifMauTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IfMauEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of descriptive and status information
|
|
about MAU(s) attached to an interface."
|
|
::= { dot3IfMauBasicGroup 1 }
|
|
|
|
ifMauEntry OBJECT-TYPE
|
|
SYNTAX IfMauEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table, containing information
|
|
about a single MAU."
|
|
INDEX { ifMauIfIndex,
|
|
ifMauIndex
|
|
}
|
|
::= { ifMauTable 1 }
|
|
|
|
IfMauEntry ::=
|
|
SEQUENCE {
|
|
ifMauIfIndex InterfaceIndex,
|
|
ifMauIndex Integer32,
|
|
ifMauType AutonomousType,
|
|
ifMauStatus INTEGER,
|
|
ifMauMediaAvailable IANAifMauMediaAvailable,
|
|
ifMauMediaAvailableStateExits Counter32,
|
|
ifMauJabberState INTEGER,
|
|
ifMauJabberingStateEnters Counter32,
|
|
ifMauFalseCarriers Counter32,
|
|
ifMauDefaultType AutonomousType,
|
|
ifMauAutoNegSupported TruthValue,
|
|
ifMauTypeListBits IANAifMauTypeListBits,
|
|
ifMauHCFalseCarriers Counter64,
|
|
ifMauPCSCodingViolations Counter64,
|
|
ifMauFECAbility INTEGER,
|
|
ifMauFECMode INTEGER,
|
|
ifMauFECCorrectedBlocks Counter64,
|
|
ifMauFECUnCorrectableBlocks Counter64,
|
|
ifMauSNROpMarginChnlA Integer32,
|
|
ifMauSNROpMarginChnlB Integer32,
|
|
ifMauSNROpMarginChnlC Integer32,
|
|
ifMauSNROpMarginChnlD Integer32,
|
|
ifMauEEESupportList IANAifMauTypeListBits,
|
|
ifMauEEELDFastRetrainCount Counter32,
|
|
ifMauEEELPFastRetrainCount Counter32,
|
|
ifMauTimeSyncCapabilityTX TruthValue,
|
|
ifMauTimeSyncCapabilityRX TruthValue,
|
|
ifMauTimeSyncDelayTXmax Integer32,
|
|
ifMauTimeSyncDelayTXmin Integer32,
|
|
ifMauTimeSyncDelayRXmax Integer32,
|
|
ifMauTimeSyncDelayRXmin Integer32
|
|
}
|
|
|
|
ifMauIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This variable uniquely identifies the interface
|
|
to which the MAU described by this entry is
|
|
connected."
|
|
REFERENCE "RFC 2863, ifIndex"
|
|
::= { ifMauEntry 1 }
|
|
|
|
ifMauIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This variable uniquely identifies the MAU
|
|
described by this entry from among other MAUs
|
|
connected to the same interface (ifMauIfIndex)."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.1, aMAUID."
|
|
::= { ifMauEntry 2 }
|
|
|
|
ifMauType OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the MAU type. Values for
|
|
standard IEEE 802.3 MAU types are defined in the
|
|
IANA maintained IANA-MAU-MIB module, as
|
|
OBJECT-IDENTITIES of dot3MauType.
|
|
If the MAU type is unknown, the object identifier
|
|
zeroDotZero is returned.
|
|
|
|
This object represents the operational type of
|
|
the MAU, as determined by either 1) the result
|
|
of the Auto-Negotiation function or 2) if
|
|
Auto-Negotiation is not enabled or is not
|
|
implemented for this MAU, by the value of the
|
|
object ifMauDefaultType. In case 2), a set to
|
|
the object ifMauDefaultType will force the MAU
|
|
into the new operating mode."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.2, aMAUType."
|
|
::= { ifMauEntry 3 }
|
|
|
|
ifMauStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
unknown(2),
|
|
operational(3),
|
|
standby(4),
|
|
shutdown(5),
|
|
reset(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "The current state of the MAU. This object may
|
|
be implemented as a read-only object by those
|
|
agents and MAUs that do not implement software
|
|
control of the MAU state. Some agents may not
|
|
support setting the value of this object to some
|
|
of the enumerated values.
|
|
|
|
The value other(1) is returned if the MAU is in
|
|
a state other than one of the states 2 through
|
|
6.
|
|
|
|
The value unknown(2) is returned when the MAU's
|
|
true state is unknown; for example, when it is
|
|
being initialized.
|
|
|
|
A MAU in the operational(3) state is fully
|
|
functional; it operates, and passes signals to its
|
|
attached DTE or repeater port in accordance to
|
|
its specification.
|
|
|
|
A MAU in standby(4) state forces DI and CI to
|
|
idle and the media transmitter to idle or fault,
|
|
if supported. Standby(4) mode only applies to
|
|
link type MAUs. The state of
|
|
ifMauMediaAvailable is unaffected.
|
|
|
|
A MAU in shutdown(5) state assumes the same
|
|
condition on DI, CI, and the media transmitter,
|
|
as though it were powered down or not connected.
|
|
The MAU may return other(1) value for the
|
|
ifMauJabberState and ifMauMediaAvailable objects
|
|
when it is in this state. For an AUI, this
|
|
state will remove power from the AUI.
|
|
|
|
Setting this variable to the value reset(6)
|
|
resets the MAU in the same manner as a
|
|
power-off, power-on cycle of at least one-half
|
|
second would. The agent is not required to
|
|
return the value reset(6).
|
|
|
|
Setting this variable to the value
|
|
operational(3), standby(4), or shutdown(5)
|
|
causes the MAU to assume the respective state,
|
|
except that setting a mixing-type MAU or an AUI
|
|
to standby(4) will cause the MAU to enter the
|
|
shutdown state."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.7, aMAUAdminState,
|
|
30.5.1.2.2, acMAUAdminControl, and 30.5.1.2.1,
|
|
acResetMAU."
|
|
::= { ifMauEntry 4 }
|
|
|
|
ifMauMediaAvailable OBJECT-TYPE
|
|
SYNTAX IANAifMauMediaAvailable
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object identifies Media Available state of
|
|
the MAU, complementary to the ifMauStatus. Values
|
|
for the standard IEEE 802.3 Media Available states
|
|
are defined in the IANA maintained IANA-MAU-MIB
|
|
module, as IANAifMauMediaAvailable TC."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.4, aMediaAvailable."
|
|
::= { ifMauEntry 5 }
|
|
|
|
ifMauMediaAvailableStateExits OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of times that
|
|
ifMauMediaAvailable for this MAU instance leaves
|
|
the state available(3).
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management
|
|
system and at other times, as indicated by the
|
|
value of ifCounterDiscontinuityTime."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.5, aLoseMediaCounter.
|
|
RFC 2863, ifCounterDiscontinuityTime."
|
|
::= { ifMauEntry 6 }
|
|
|
|
ifMauJabberState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
unknown(2),
|
|
noJabber(3),
|
|
jabbering(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The value other(1) is returned if the jabber
|
|
state is not 2, 3, or 4. The agent shall
|
|
return other(1) for MAU type dot3MauTypeAUI.
|
|
|
|
The value unknown(2) is returned when the MAU's
|
|
true state is unknown; for example, when it is
|
|
being initialized.
|
|
|
|
If the MAU is not jabbering the agent returns
|
|
noJabber(3). This is the 'normal' state.
|
|
|
|
If the MAU is in jabber state the agent returns
|
|
the jabbering(4) value."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.6, aJabber.jabberFlag."
|
|
::= { ifMauEntry 7 }
|
|
|
|
ifMauJabberingStateEnters OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of times that
|
|
mauJabberState for this MAU instance enters the
|
|
state jabbering(4). This counter will
|
|
indicate zero for MAUs of type dot3MauTypeAUI
|
|
and those of speeds above 10 Mb/s.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management
|
|
system and at other times, as indicated by the
|
|
value of ifCounterDiscontinuityTime."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.6, aJabber.jabberCounter.
|
|
RFC 2863, ifCounterDiscontinuityTime."
|
|
::= { ifMauEntry 8 }
|
|
|
|
ifMauFalseCarriers OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of false carrier events
|
|
during IDLE in 100BASE-X and 1000BASE-X links.
|
|
|
|
For all other MAU types, this counter will
|
|
indicate zero. This counter does not
|
|
increment at the symbol rate.
|
|
|
|
It can increment after a valid carrier
|
|
completion at a maximum rate of once per 100 ms
|
|
for 100BASE-X and once per 10us for 1000BASE-X
|
|
until the next CarrierEvent.
|
|
|
|
This counter can roll over very quickly. A
|
|
management station is advised to poll the
|
|
ifMauHCFalseCarriers instead of this counter in
|
|
order to avoid loss of information.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management
|
|
system and at other times, as indicated by the
|
|
value of ifCounterDiscontinuityTime."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.10, aFalseCarriers.
|
|
RFC 2863, ifCounterDiscontinuityTime."
|
|
::= { ifMauEntry 9 }
|
|
|
|
ifMauDefaultType OBJECT-TYPE
|
|
SYNTAX AutonomousType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object identifies the default
|
|
administrative baseband MAU type to be used in
|
|
conjunction with the operational MAU type
|
|
denoted by ifMauType.
|
|
|
|
The set of possible values for this object is
|
|
the same as the set defined for the ifMauType
|
|
object.
|
|
|
|
This object represents the
|
|
administratively-configured type of the MAU. If
|
|
Auto-Negotiation is not enabled or is not
|
|
implemented for this MAU, the value of this
|
|
object determines the operational type of the
|
|
MAU. In this case, a set to this object will
|
|
force the MAU into the specified operating mode.
|
|
|
|
If Auto-Negotiation is implemented and enabled
|
|
for this MAU, the operational type of the MAU
|
|
is determined by Auto-Negotiation, and the value
|
|
of this object denotes the type to which the MAU
|
|
will automatically revert if/when
|
|
Auto-Negotiation is later disabled.
|
|
|
|
It may be necessary to provide for underlying hardware
|
|
implementations which do not follow the exact behavior
|
|
specified above.
|
|
In particular, when ifMauAutoNegAdminStatus transitions
|
|
from enabled to disabled, the agent implementation shall
|
|
verify that the operational type of the MAU
|
|
(as reported by ifMauType) correctly transitions to
|
|
the value specified by this object, rather than
|
|
continuing to operate at the value earlier
|
|
determined by the Auto-Negotiation function."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.1, aMAUID, and 22.2.4.1.4."
|
|
::= { ifMauEntry 10 }
|
|
|
|
ifMauAutoNegSupported OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates whether or not
|
|
Auto-Negotiation is supported on this MAU."
|
|
::= { ifMauEntry 11 }
|
|
|
|
ifMauTypeListBits OBJECT-TYPE
|
|
SYNTAX IANAifMauTypeListBits
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A value that uniquely identifies the set of
|
|
possible IEEE 802.3 types that the MAU could be.
|
|
If Auto-Negotiation is present on this MAU, this
|
|
object will map to ifMauAutoNegCapabilityBits.
|
|
|
|
Note that this MAU may be capable of operating
|
|
as a MAU type that is beyond the scope of this
|
|
MIB. This is indicated by returning the
|
|
bit value bOther in addition to any bit values
|
|
for standard capabilities that are listed in the
|
|
IANAifMauTypeListBits TC."
|
|
::= { ifMauEntry 12 }
|
|
|
|
ifMauHCFalseCarriers OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of false carrier events
|
|
during IDLE in 100BASE-X and 1000BASE-X links.
|
|
|
|
For all other MAU types, this counter will
|
|
indicate zero. This counter does not
|
|
increment at the symbol rate.
|
|
|
|
This counter is a 64-bit version of
|
|
ifMauFalseCarriers. Since the 32-bit version of
|
|
this counter can roll over very quickly,
|
|
management stations are advised to poll the
|
|
64-bit version instead, in order to avoid loss
|
|
of information.
|
|
|
|
Discontinuities in the value of this counter can
|
|
occur at re-initialization of the management
|
|
system and at other times, as indicated by the
|
|
value of ifCounterDiscontinuityTime."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.10, aFalseCarriers.
|
|
RFC 2863, ifCounterDiscontinuityTime."
|
|
::= { ifMauEntry 13 }
|
|
|
|
ifMauPCSCodingViolations OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Generalized nonresettable counter. This counter
|
|
has a maximum increment rate of 25 000 000
|
|
counts per second for 100 Mb/s implementations and
|
|
125 000 000 counts per second for 1000 Mb/s
|
|
implementations.
|
|
|
|
For 100 Mb/s operation it is a count of the number
|
|
of events that cause the PHY to indicate 'Data
|
|
reception with errors' on the MII (see IEEE Std 802.3
|
|
Table 22?2).
|
|
|
|
For 1000 Mb/s operation it is a count of the
|
|
number of events that cause the PHY to indicate 'Data
|
|
reception error' or 'Carrier Extend Error' on the GMII
|
|
(see IEEE Std 802.3, Table 35?2). The contents of this
|
|
attribute is undefined when FEC is operating."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.14 aPCSCodingViolations."
|
|
::= {ifMauEntry 14}
|
|
|
|
ifMauFECAbility OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
supported(2),
|
|
notsupported(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A read-only value that indicates if the
|
|
PHY supports an optional FEC sublayer for
|
|
forward error correction (see IEEE Std 802.3, 65.2
|
|
and IEEE Std 802.3, Clause 74).
|
|
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to the
|
|
PCS is present, then this attribute will map to the
|
|
FEC capability register (see IEEE Std 802.3, 45.2.8.2)."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.15 aFECAbility."
|
|
::= {ifMauEntry 15}
|
|
|
|
ifMauFECMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
disabled(2),
|
|
enabled(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A read-write value that indicates the mode of
|
|
operation of the optional FEC sublayer for forward
|
|
error correction (see IEEE Std 802.3, 65.2 and
|
|
IEEE Std 802.3, Clause 74).
|
|
|
|
A GET operation returns the current mode of operation
|
|
of the PHY. A SET operation changes the mode of
|
|
operation of the PHY to the indicated value. When
|
|
IEEE Std 802.3 Clause 73 Auto-Negotiation is enabled
|
|
a SET operation is not allowed and a GET operation maps
|
|
to the variable FEC enabled in Clause 74.
|
|
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to the
|
|
PCS is present, then this object will map to the FEC
|
|
control register (see IEEE Std 802.3 45.2.8.3) for
|
|
1000BASE-PX or FEC enable bit in the BASE-R FEC control
|
|
register (see IEEE Std 802.3 45.2.1.90)."
|
|
REFERENCE "IEEE Std 802.3. 30.5.1.1.16 aFECMode."
|
|
::= {ifMauEntry 16}
|
|
|
|
ifMauFECCorrectedBlocks OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"********** THIS OBJECT IS DEPRECATED **********
|
|
|
|
Generalized nonresettable counter. This counter
|
|
has a maximum increment rate of 1 200 000
|
|
counts per second for 1000 Mb/s implementations,
|
|
and 5 000 000 counts per second for 10 Gb/s
|
|
implementations.
|
|
|
|
For 1000BASE-PX PHYs or 10GBASE-R PHYs, a count
|
|
of corrected FEC blocks. This counter will not
|
|
increment for other PHY types.
|
|
Increment the counter by one for each received block
|
|
that is corrected by the FEC function in the PHY.
|
|
If a Clause 45 MDIO Interface to the PCS is present,
|
|
then this object will map to the FEC corrected blocks
|
|
counter (see IEEE Std 802.3, 45.2.8.5 and 45.2.1.91)"
|
|
REFERENCE "IEEE Std 802.3. 30.5.1.1.17 aFECCorrectedBlocks."
|
|
::= {ifMauEntry 17}
|
|
|
|
ifMauFECUnCorrectableBlocks OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"********** THIS OBJECT IS DEPRECATED **********
|
|
|
|
Generalized nonresettable counter. This counter
|
|
has a maximum increment rate of 1 200 000
|
|
counts per second for 1000 Mb/s implementations,
|
|
and 5 000 000 counts per second for 10 Gb/s
|
|
implementations.
|
|
|
|
For 1000BASE-PX PHYs or 10GBASE-R PHYs, a count
|
|
of uncorrectable FEC blocks. This counter will not
|
|
increment for other PHY types.
|
|
Increment the counter by one for each received block
|
|
that is determined to be uncorrectable by the FEC
|
|
function in the PHY.
|
|
|
|
If a Clause 45 MDIO Interface to the PCS is present,
|
|
then this object will map to the FEC uncorrectable
|
|
blocks counter (see IEEE Std 802.3 45.2.8.6 and
|
|
45.2.1.92)"
|
|
REFERENCE "IEEE Std 802.3. 30.5.1.1.18 aFECUnCorrectableBlocks."
|
|
::= {ifMauEntry 18}
|
|
|
|
ifMauSNROpMarginChnlA OBJECT-TYPE
|
|
SYNTAX Integer32 (-127..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current SNR operating margin measured at the
|
|
slicer input for channel A for the 10GBASE-T PMA.
|
|
It is reported in units of 0.1 dB to an accuracy of
|
|
0.5 dB within the range of -12.7 dB to 12.7 dB.
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to the
|
|
PMA/PMD is present, then this attribute maps to the SNR
|
|
operating margin channel A register
|
|
(see IEEE Std 802.3, 45.2.1.65)."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.19 aSNROpMarginChnlA."
|
|
::= {ifMauEntry 19}
|
|
|
|
ifMauSNROpMarginChnlB OBJECT-TYPE
|
|
SYNTAX Integer32 (-127..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current SNR operating margin measured at the
|
|
slicer input for channel B for the 10GBASE-T PMA.
|
|
It is reported in units of 0.1 dB to an accuracy of
|
|
0.5 dB within the range of -12.7 dB to 12.7 dB.
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to the
|
|
PMA/PMD is present, then this attribute maps to the SNR
|
|
operating margin channel B register
|
|
(see IEEE Std 802.3, 45.2.1.66)."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.20 aSNROpMarginChnlB."
|
|
::= {ifMauEntry 20}
|
|
|
|
ifMauSNROpMarginChnlC OBJECT-TYPE
|
|
SYNTAX Integer32 (-127..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current SNR operating margin measured at the
|
|
slicer input for channel C for the 10GBASE-T PMA.
|
|
It is reported in units of 0.1 dB to an accuracy of
|
|
0.5 dB within the range of -12.7 dB to 12.7 dB.
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to the
|
|
PMA/PMD is present, then this attribute maps to the SNR
|
|
operating margin channel C register
|
|
(see IEEE Std 802.3, 45.2.1.67)."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.21 aSNROpMarginChnlC."
|
|
::= {ifMauEntry 21}
|
|
|
|
ifMauSNROpMarginChnlD OBJECT-TYPE
|
|
SYNTAX Integer32 (-127..127)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current SNR operating margin measured at the
|
|
slicer input for channel D for the 10GBASE-T PMA.
|
|
It is reported in units of 0.1 dB to an accuracy of
|
|
0.5 dB within the range of -12.7 dB to 12.7 dB.
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to the
|
|
PMA/PMD is present, then this attribute maps to the SNR
|
|
operating margin channel D register
|
|
(see IEEE Std 802.3, 45.2.1.68)."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.22 aSNROpMarginChnlD."
|
|
::= {ifMauEntry 22}
|
|
|
|
ifMauEEESupportList OBJECT-TYPE
|
|
SYNTAX IANAifMauTypeListBits
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A read-only list of the possible PHY types for which
|
|
the underlying system supports Energy-Efficient Ethernet
|
|
(EEE) as defined in IEEE Std 802.3 Clause 78."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.23 aEEESupportList."
|
|
::= { ifMauEntry 23 }
|
|
|
|
ifMauEEELDFastRetrainCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of 10GBASE-T fast retrains
|
|
initiated by the local device. The indication reflects
|
|
the state of the PHY event counter (see IEEE Std 802.3,
|
|
45.2.1.78.2 and 55.4.5.1.)"
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.24 aLDFastRetrainCount."
|
|
::= { ifMauEntry 24 }
|
|
|
|
ifMauEEELPFastRetrainCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A count of the number of 10GBASE-T fast retrains
|
|
initiated by the link partner. The indication reflects
|
|
the state of the PHY event counter (see IEEE Std 802.3,
|
|
45.2.1.78.1 and 55.4.5.1.)"
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.25 aLPFastRetrainCount."
|
|
::= { ifMauEntry 25 }
|
|
|
|
ifMauTimeSyncCapabilityTX OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates whether or not transmit
|
|
Time Sync is supported on this MAU."
|
|
REFERENCE "IEEE Std 802.3, 30.13.1.1 aTimeSyncCapabilityTX."
|
|
::= { ifMauEntry 26 }
|
|
|
|
ifMauTimeSyncCapabilityRX OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates whether or not receive
|
|
Time Sync is supported on this MAU."
|
|
REFERENCE "IEEE Std 802.3, 30.13.1.2 aTimeSyncCapabilityRX."
|
|
::= { ifMauEntry 27 }
|
|
|
|
ifMauTimeSyncDelayTXmax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum data delay as specified in IEEE Std 802.3
|
|
90.7, expressed in units of ns.
|
|
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to
|
|
PMA/PMD, WIS, PCS, PHY XS, DTE XS and/or TC is
|
|
present, then the value stored in this attribute
|
|
represents the maximum transmit path data delay
|
|
values, consisting of the sum of the values of the
|
|
registers in the instantiated sublayers (for each MMD,
|
|
in case of multiple instances)"
|
|
REFERENCE "IEEE Std 802.3, 30.13.1.3 aTimeSyncDelayTXmax."
|
|
::= { ifMauEntry 28 }
|
|
|
|
ifMauTimeSyncDelayTXmin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The minimum data delay as specified in IEEE Std 802.3
|
|
90.7, expressed in units of ns.
|
|
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to
|
|
PMA/PMD, WIS, PCS, PHY XS, DTE XS and/or TC is
|
|
present, then the value stored in this attribute
|
|
represents the minimum transmit path data delay
|
|
values, consisting of the sum of the values of the
|
|
registers in the instantiated sublayers (for each MMD,
|
|
in case of multiple instances)"
|
|
REFERENCE "IEEE Std 802.3, 30.13.1.4 aTimeSyncDelayTXmin."
|
|
::= { ifMauEntry 29 }
|
|
|
|
ifMauTimeSyncDelayRXmax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The maximum data delay as specified in IEEE Std 802.3
|
|
90.7, expressed in units of ns.
|
|
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to
|
|
PMA/PMD, WIS, PCS, PHY XS, DTE XS and/or TC is
|
|
present, then the value stored in this attribute
|
|
represents the maximum receive path data delay
|
|
values, consisting of the sum of the values of the
|
|
registers in the instantiated sublayers (for each MMD,
|
|
in case of multiple instances)"
|
|
REFERENCE "IEEE Std 802.3, 30.13.1.5 aTimeSyncDelayRXmax."
|
|
::= { ifMauEntry 30 }
|
|
|
|
ifMauTimeSyncDelayRXmin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The minimum data delay as specified in IEEE Std 802.3
|
|
90.7, expressed in units of ns.
|
|
|
|
If an IEEE Std 802.3 Clause 45 MDIO Interface to
|
|
PMA/PMD, WIS, PCS, PHY XS, DTE XS and/or TC is
|
|
present, then the value stored in this attribute
|
|
represents the minimum receive path data delay
|
|
values, consisting of the sum of the values of the
|
|
registers in the instantiated sublayers (for each MMD,
|
|
in case of multiple instances)"
|
|
REFERENCE "IEEE Std 802.3, 30.13.1.6 aTimeSyncDelayRXmin."
|
|
::= { ifMauEntry 31 }
|
|
|
|
|
|
-- The ifJackTable applies to MAUs attached to interfaces
|
|
-- which have one or more external jacks (connectors).
|
|
|
|
ifJackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IfJackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Information about the external jacks attached
|
|
to MAUs attached to an interface."
|
|
::= { dot3IfMauBasicGroup 2 }
|
|
|
|
ifJackEntry OBJECT-TYPE
|
|
SYNTAX IfJackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table, containing information
|
|
about a particular jack."
|
|
INDEX { ifMauIfIndex,
|
|
ifMauIndex,
|
|
ifJackIndex
|
|
}
|
|
::= { ifJackTable 1 }
|
|
|
|
IfJackEntry ::=
|
|
SEQUENCE {
|
|
ifJackIndex Integer32,
|
|
ifJackType IANAifJackType
|
|
}
|
|
|
|
ifJackIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This variable uniquely identifies the jack
|
|
described by this entry from among other jacks
|
|
attached to the same MAU."
|
|
::= { ifJackEntry 1 }
|
|
|
|
ifJackType OBJECT-TYPE
|
|
SYNTAX IANAifJackType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The jack connector type, as it appears on the
|
|
outside of the system."
|
|
::= { ifJackEntry 2 }
|
|
|
|
--
|
|
-- The MAU Per-PCS Lane Statistics Table
|
|
--
|
|
|
|
ifMauPerPCSLaneStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IfMauPerPCSLaneStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Table of Per-PCS lane status information
|
|
about MAUs attached to an interface."
|
|
::= { dot3IfMauBasicGroup 3 }
|
|
|
|
ifMauPerPCSLaneStatsEntry OBJECT-TYPE
|
|
SYNTAX IfMauPerPCSLaneStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table, containing information
|
|
about a single PCS lane."
|
|
INDEX { ifMauIfIndex,
|
|
ifMauIndex,
|
|
ifPCSLaneIndex
|
|
}
|
|
::= { ifMauPerPCSLaneStatsTable 1 }
|
|
|
|
IfMauPerPCSLaneStatsEntry ::=
|
|
SEQUENCE {
|
|
ifPCSLaneIndex Unsigned32,
|
|
ifMauPPLFECCorrectedBlocks Counter64,
|
|
ifMauPPLFECUncorrectableBlocks Counter64,
|
|
ifMauBIPErrorCount Counter32,
|
|
ifMauPCStoPHYLaneMapping Unsigned32
|
|
}
|
|
|
|
ifPCSLaneIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..255)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object provides the identification of the
|
|
PCS lane for which this ifMauPerPCSLaneStatsEntry
|
|
is applicable. This object can hold an integer value
|
|
from 0 to N-1, where N is the total number of PCS
|
|
lanes supported by the given PCS. "
|
|
::= { ifMauPerPCSLaneStatsEntry 1 }
|
|
|
|
ifMauPPLFECCorrectedBlocks OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Generalized nonresettable counter. This counter has a
|
|
maximum increment rate of 1 200 000 counts per second
|
|
for 1000 Mb/s implementations, 5 000 000 counts per
|
|
second for 10 Gb/s and 40 Gb/s implementations, and
|
|
2 500 000 counts per second for 100 Gb/s implementations.
|
|
|
|
For 1000BASE-PX, 10/40/100GBASE-R PHYs, a count of
|
|
corrected FEC blocks received on the PSC lane identified
|
|
by ifPCSLaneIndex object. This counter will not increment
|
|
for other PHY types.
|
|
|
|
Increment the counter by one for each received block that
|
|
is corrected by the FE C function in the PHY for the
|
|
corresponding lane identified by the ifPCSLaneIndex
|
|
object.
|
|
|
|
If a Clause 45 MDIO Interface to the PCS is present,
|
|
then this object will map to the FEC corrected blocks
|
|
counter for PCS lane number n, identified by the
|
|
ifPCSLaneIndex object
|
|
(see IEEE Std 802.3 45.2.8.5, 45.2.1.91 , and 45.2.1.93)."
|
|
REFERENCE "IEEE Std 802.3 30.5.1.1.17"
|
|
::= { ifMauPerPCSLaneStatsEntry 2 }
|
|
|
|
ifMauPPLFECUncorrectableBlocks OBJECT-TYPE
|
|
SYNTAX Counter64
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Generalized nonresettable counter. This counter has a
|
|
maximum increment rate of 1 200 000 counts per second
|
|
for 1000 Mb/s implementations, 5 000 000 counts
|
|
per second for 10 Gb/s and 40 Gb/s implementations,
|
|
and 2 500 000 counts per second for 100 Gb/s
|
|
implementations.
|
|
|
|
For 1000BASE-PX, 10/40/100GBASE-R PHYs, a count of
|
|
uncorrectable FEC blocks received on the PSC lane
|
|
identified by ifPCSLaneIndex object. This counter will
|
|
not increment for other PHY types.
|
|
|
|
Increment the counter by one for each FEC block that
|
|
is determined to be uncorrectable by the FEC function
|
|
in the PHY for the corresponding lane identified by
|
|
the ifPCSLaneIndex object.
|
|
|
|
If a Clause 45 MDIO Interface to the PCS is present,
|
|
then this object will map to the FEC uncorrectable
|
|
blocks counter for PSC lane number n, identified by
|
|
the ifPCSLaneIndex object
|
|
(see IEEE Std 802.3 45.2.8.6, 45.2.1.92, and 45.2.1.94)."
|
|
REFERENCE "IEEE Std 802.3 30.5.1.1.18"
|
|
::= { ifMauPerPCSLaneStatsEntry 3 }
|
|
|
|
ifMauBIPErrorCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Generalized nonresettable counter. This counter
|
|
has a maximum increment rate of 10 000 counts per
|
|
second for 40 Gb/s implementations and 5 000 counts
|
|
per second for 100 Gb/ s implementations.
|
|
|
|
For 40/100GBASE-R PHYs, a count of BIP errors on the
|
|
PCS lane identified by ifPCSLaneIndex object. This
|
|
counter will not increment for other PHY types.
|
|
|
|
Increment the counter by one for each BIP error
|
|
detected during alignment marker removal in the
|
|
PCS identified by the ifPCSLaneIndex object.
|
|
|
|
If a Clause 45 MDIO Interface to the PCS is
|
|
present, then this object will map to the BIP error
|
|
counter for PCS lane number n, identified by the
|
|
ifPCSLaneIndex object
|
|
(see IEEE Std 802.3, 45.2.3.44 and 45.2.3.45)."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.1.11"
|
|
::= { ifMauPerPCSLaneStatsEntry 4 }
|
|
|
|
ifMauPCStoPHYLaneMapping OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "For 40/100GBASE-R PHYs, an array of PCS lane
|
|
identifiers. The indices of this array (0 to n?1)
|
|
denote the service interface lane number where n is
|
|
the number of PCS lanes in use. Each element of
|
|
this array contains the PCS lane number for the PCS
|
|
lane that has been detected in the corresponding
|
|
service interface lane.
|
|
|
|
If a Clause 45 MDIO Interface to the PCS is
|
|
present, then this object will map to the Lane
|
|
mapping register for PCS lane number n, identified
|
|
by the ifPCSLaneIndex object
|
|
(see IEEE Std 802.3 45.2.3.46 and 45.2.3.47)."
|
|
REFERENCE "IEEE Std 802.3 30.5.1.1.12"
|
|
::= { ifMauPerPCSLaneStatsEntry 5 }
|
|
|
|
--
|
|
-- The MAU Auto-Negotiation Table
|
|
--
|
|
|
|
ifMauAutoNegTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF IfMauAutoNegEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Configuration and status objects for the
|
|
Auto-Negotiation function of MAUs attached to
|
|
interfaces.
|
|
|
|
The ifMauAutoNegTable applies to systems in
|
|
which Auto-Negotiation is supported on one or
|
|
more MAUs attached to interfaces. Note that if
|
|
Auto-Negotiation is present and enabled, the
|
|
ifMauType object reflects the result of the
|
|
Auto-Negotiation function."
|
|
::= { dot3IfMauAutoNegGroup 1 }
|
|
|
|
ifMauAutoNegEntry OBJECT-TYPE
|
|
SYNTAX IfMauAutoNegEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the table, containing configuration
|
|
and status information for the Auto-Negotiation
|
|
function of a particular MAU."
|
|
INDEX { ifMauIfIndex,
|
|
ifMauIndex
|
|
}
|
|
::= { ifMauAutoNegTable 1 }
|
|
|
|
IfMauAutoNegEntry ::=
|
|
SEQUENCE {
|
|
ifMauAutoNegAdminStatus INTEGER,
|
|
ifMauAutoNegRemoteSignaling INTEGER,
|
|
ifMauAutoNegConfig INTEGER,
|
|
ifMauAutoNegRestart INTEGER,
|
|
ifMauAutoNegCapabilityBits IANAifMauAutoNegCapBits,
|
|
ifMauAutoNegCapAdvertisedBits IANAifMauAutoNegCapBits,
|
|
ifMauAutoNegCapReceivedBits IANAifMauAutoNegCapBits,
|
|
ifMauAutoNegRemoteFaultAdvertised INTEGER,
|
|
ifMauAutoNegRemoteFaultReceived INTEGER
|
|
}
|
|
ifMauAutoNegAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this object to enabled(1) will cause
|
|
the interface that has the Auto-Negotiation
|
|
signaling ability to be enabled.
|
|
|
|
If the value of this object is disabled(2) then
|
|
the interface will act as it would if it had no
|
|
Auto-Negotiation signaling. Under these
|
|
conditions, an IEEE 802.3 MAU will immediately
|
|
be forced to the state indicated by the value of
|
|
the object ifMauDefaultType.
|
|
|
|
When ifMauAutoNegAdminStatus transitions from enabled
|
|
to disabled, the agent implementation shall
|
|
verify that the operational type of the MAU (as
|
|
reported by ifMauType) correctly transitions to
|
|
the value specified by the ifMauDefaultType
|
|
object, rather than continuing to operate at the
|
|
value earlier determined by the Auto-Negotiation
|
|
function."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.1.2, aAutoNegAdminState,
|
|
and 30.6.1.2.2, acAutoNegAdminControl."
|
|
::= { ifMauAutoNegEntry 1 }
|
|
|
|
ifMauAutoNegRemoteSignaling OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
detected(1),
|
|
notdetected(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A value indicating whether the remote end of
|
|
the link is using Auto-Negotiation signaling. It
|
|
takes the value detected(1) if and only if,
|
|
during the previous link negotiation, FLP Bursts
|
|
were received."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.1.3,
|
|
aAutoNegRemoteSignaling."
|
|
::= { ifMauAutoNegEntry 2 }
|
|
|
|
ifMauAutoNegConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other(1),
|
|
configuring(2),
|
|
complete(3),
|
|
disabled(4),
|
|
parallelDetectFail(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A value indicating the current status of the
|
|
Auto-Negotiation process. The enumeration
|
|
parallelDetectFail(5) maps to a failure in
|
|
parallel detection as defined in 28.2.3.1 of
|
|
IEEE Std 802.3."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.1.4, aAutoNegAutoConfig."
|
|
::= { ifMauAutoNegEntry 4 }
|
|
|
|
ifMauAutoNegRestart OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
restart(1),
|
|
norestart(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "If the value of this object is set to
|
|
restart(1) then this will force Auto-Negotiation
|
|
to begin link renegotiation. If Auto-Negotiation
|
|
signaling is disabled, a write to this object
|
|
has no effect.
|
|
Setting the value of this object to norestart(2)
|
|
has no effect."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.2.1,
|
|
acAutoNegRestartAutoConfig."
|
|
::= { ifMauAutoNegEntry 5 }
|
|
|
|
ifMauAutoNegCapabilityBits OBJECT-TYPE
|
|
SYNTAX IANAifMauAutoNegCapBits
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A value that uniquely identifies the set of
|
|
capabilities of the local Auto-Negotiation
|
|
entity. Note that interfaces that support this
|
|
MIB may have capabilities that extend beyond the
|
|
scope of this MIB.
|
|
|
|
Note that the local Auto-Negotiation entity may
|
|
support some capabilities beyond the scope of
|
|
this MIB. This is indicated by returning the
|
|
bit value bOther in addition to any bit values
|
|
for standard capabilities that are listed in the
|
|
IANAifMauAutoNegCapBits TC."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.1.5,
|
|
aAutoNegLocalTechnologyAbility."
|
|
::= { ifMauAutoNegEntry 6 }
|
|
|
|
ifMauAutoNegCapAdvertisedBits OBJECT-TYPE
|
|
SYNTAX IANAifMauAutoNegCapBits
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A value that uniquely identifies the set of
|
|
capabilities advertised by the local
|
|
Auto-Negotiation entity.
|
|
|
|
Capabilities in this object that are not
|
|
available in ifMauAutoNegCapabilityBits cannot
|
|
be enabled.
|
|
|
|
Note that the local Auto-Negotiation entity may
|
|
advertise some capabilities beyond the scope of
|
|
this MIB. This is indicated by returning the
|
|
bit value bOther in addition to any bit values
|
|
for standard capabilities that are listed in the
|
|
IANAifMauAutoNegCapBits TC."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.1.6,
|
|
aAutoNegAdvertisedTechnologyAbility."
|
|
::= { ifMauAutoNegEntry 7 }
|
|
|
|
ifMauAutoNegCapReceivedBits OBJECT-TYPE
|
|
SYNTAX IANAifMauAutoNegCapBits
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A value that uniquely identifies the set of
|
|
capabilities received from the remote
|
|
Auto-Negotiation entity.
|
|
Note that interfaces that support this MIB may
|
|
be attached to remote Auto-Negotiation entities
|
|
that have capabilities beyond the scope of this
|
|
MIB. This is indicated by returning the bit
|
|
value bOther in addition to any bit values for
|
|
standard capabilities that are listed in the
|
|
IANAifMauAutoNegCapBits TC."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.1.7,
|
|
aAutoNegReceivedTechnologyAbility."
|
|
::= { ifMauAutoNegEntry 8 }
|
|
|
|
ifMauAutoNegRemoteFaultAdvertised OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(1),
|
|
offline(2),
|
|
linkFailure(3),
|
|
autoNegError(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "A value that identifies any local fault
|
|
indications that this MAU has detected and will
|
|
advertise at the next Auto-Negotiation
|
|
interaction for 1000 Mb/s MAUs."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.1.6,
|
|
aAutoNegAdvertisedTechnologyAbility."
|
|
::= { ifMauAutoNegEntry 9 }
|
|
|
|
ifMauAutoNegRemoteFaultReceived OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noError(1),
|
|
offline(2),
|
|
linkFailure(3),
|
|
autoNegError(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A value that identifies any fault indications
|
|
received from the far end of a link by the
|
|
local Auto-Negotiation entity for 1000 Mb/s
|
|
MAUs."
|
|
REFERENCE "IEEE Std 802.3, 30.6.1.1.7,
|
|
aAutoNegReceivedTechnologyAbility."
|
|
::= { ifMauAutoNegEntry 10 }
|
|
|
|
-- Placeholder to preserve module structure and assignments
|
|
dot3Placeholder OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
placeholder(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "A placeholder object to preserve the assignments
|
|
that follow in the module. The assignment was given
|
|
to the object broadMauBasicTable in earlier
|
|
versions of this module. Preserving the assignments that
|
|
follow is considered important because they are used for
|
|
the IANA-MAU-MIB to assign as MAU type values."
|
|
REFERENCE "none"
|
|
::= { dot3PlaceholderGroup 1 }
|
|
|
|
-- Notifications for use by 802.3 MAUs
|
|
|
|
snmpDot3MauTraps OBJECT IDENTIFIER ::= { ieee8023snmpDot3MauMgt 0 }
|
|
|
|
rpMauJabberTrap NOTIFICATION-TYPE
|
|
OBJECTS { rpMauJabberState }
|
|
STATUS current
|
|
DESCRIPTION "This trap is sent whenever a managed repeater
|
|
MAU enters the jabber state.
|
|
|
|
The agent shall limit the generation of
|
|
consecutive rpMauJabberTraps so that there is at
|
|
least a five-second gap between them."
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.3.1, nJabber notification."
|
|
::= { snmpDot3MauTraps 1 }
|
|
|
|
ifMauJabberTrap NOTIFICATION-TYPE
|
|
OBJECTS { ifMauJabberState }
|
|
STATUS current
|
|
DESCRIPTION "This trap is sent whenever a managed interface
|
|
MAU enters the jabber state.
|
|
|
|
The agent shall limit the generation of
|
|
consecutive ifMauJabberTraps so that there is at
|
|
least a five-second gap between them."
|
|
|
|
REFERENCE "IEEE Std 802.3, 30.5.1.3.1, nJabber notification."
|
|
::= { snmpDot3MauTraps 2 }
|
|
|
|
-- Conformance statements
|
|
|
|
mauModConf
|
|
OBJECT IDENTIFIER ::= { ieee8023mauMIB 2 }
|
|
mauModCompls
|
|
OBJECT IDENTIFIER ::= { mauModConf 1 }
|
|
mauModObjGrps
|
|
OBJECT IDENTIFIER ::= { mauModConf 2 }
|
|
mauModNotGrps
|
|
OBJECT IDENTIFIER ::= { mauModConf 3 }
|
|
|
|
-- Object groups
|
|
mauRpGrpBasic OBJECT-GROUP
|
|
OBJECTS { rpMauType,
|
|
rpMauStatus,
|
|
rpMauMediaAvailable,
|
|
rpMauMediaAvailableStateExits,
|
|
rpMauJabberState,
|
|
rpMauJabberingStateEnters
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Basic conformance group for MAUs attached to
|
|
repeater ports. This group is also the
|
|
conformance specification for RFC 1515
|
|
implementations."
|
|
::= { mauModObjGrps 1 }
|
|
|
|
mauRpGrp100Mbs OBJECT-GROUP
|
|
OBJECTS { rpMauFalseCarriers }
|
|
STATUS current
|
|
DESCRIPTION "Conformance group for MAUs attached to
|
|
repeater ports with 100 Mb/s or greater
|
|
capability."
|
|
::= { mauModObjGrps 2 }
|
|
|
|
mauRpGrpJack OBJECT-GROUP
|
|
OBJECTS { rpJackType }
|
|
STATUS current
|
|
DESCRIPTION "Conformance group for MAUs attached to
|
|
repeater ports with managed jacks."
|
|
::= { mauModObjGrps 3 }
|
|
|
|
mauIfGrpBasic OBJECT-GROUP
|
|
OBJECTS { ifMauType,
|
|
ifMauStatus,
|
|
ifMauMediaAvailable,
|
|
ifMauMediaAvailableStateExits,
|
|
ifMauJabberState,
|
|
ifMauJabberingStateEnters,
|
|
dot3Placeholder
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Basic conformance group for MAUs attached to
|
|
interfaces. This group also provides a
|
|
conformance specification for RFC 1515
|
|
implementations."
|
|
::= { mauModObjGrps 4 }
|
|
|
|
mauIfGrpJack OBJECT-GROUP
|
|
OBJECTS { ifJackType }
|
|
STATUS current
|
|
DESCRIPTION "Conformance group for MAUs attached to
|
|
interfaces with managed jacks."
|
|
::= { mauModObjGrps 5 }
|
|
|
|
mauIfGrpHighCapacity OBJECT-GROUP
|
|
OBJECTS { ifMauFalseCarriers,
|
|
ifMauTypeListBits,
|
|
ifMauDefaultType,
|
|
ifMauAutoNegSupported
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance group for MAUs attached to
|
|
interfaces with 100 Mb/s or greater capability."
|
|
::= { mauModObjGrps 6 }
|
|
|
|
mauIfGrpAutoNeg2 OBJECT-GROUP
|
|
OBJECTS { ifMauAutoNegAdminStatus,
|
|
ifMauAutoNegRemoteSignaling,
|
|
ifMauAutoNegConfig,
|
|
ifMauAutoNegCapabilityBits,
|
|
ifMauAutoNegCapAdvertisedBits,
|
|
ifMauAutoNegCapReceivedBits,
|
|
ifMauAutoNegRestart
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance group for MAUs attached to
|
|
interfaces with managed Auto-Negotiation."
|
|
::= { mauModObjGrps 7 }
|
|
|
|
mauIfGrpAutoNeg1000Mbps OBJECT-GROUP
|
|
OBJECTS { ifMauAutoNegRemoteFaultAdvertised,
|
|
ifMauAutoNegRemoteFaultReceived
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance group for 1000 Mb/s MAUs attached to
|
|
interfaces with managed Auto-Negotiation."
|
|
::= { mauModObjGrps 8 }
|
|
|
|
mauIfGrpHCStats OBJECT-GROUP
|
|
OBJECTS { ifMauHCFalseCarriers,
|
|
ifMauPCSCodingViolations
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance for high capacity statistics for
|
|
MAUs attached to interfaces."
|
|
::= { mauModObjGrps 9 }
|
|
|
|
mauIfGrpFEC OBJECT-GROUP
|
|
OBJECTS { ifMauFECAbility,
|
|
ifMauFECMode,
|
|
ifMauFECCorrectedBlocks,
|
|
ifMauFECUnCorrectableBlocks
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance for FEC capable
|
|
MAUs attached to interfaces."
|
|
::= { mauModObjGrps 10 }
|
|
|
|
mauIfGrpSNR OBJECT-GROUP
|
|
OBJECTS { ifMauSNROpMarginChnlA,
|
|
ifMauSNROpMarginChnlB,
|
|
ifMauSNROpMarginChnlC,
|
|
ifMauSNROpMarginChnlD
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance for SNR operating margin reporting
|
|
MAUs attached to interfaces."
|
|
::= { mauModObjGrps 11 }
|
|
|
|
mauIfGrpEEE OBJECT-GROUP
|
|
OBJECTS { ifMauEEESupportList,
|
|
ifMauEEELDFastRetrainCount,
|
|
ifMauEEELPFastRetrainCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance EEE support and Fast Retrain count
|
|
reporting MAUs attached to interfaces."
|
|
::= { mauModObjGrps 12 }
|
|
|
|
mauIfGrpTimeSync OBJECT-GROUP
|
|
OBJECTS { ifMauTimeSyncCapabilityTX,
|
|
ifMauTimeSyncCapabilityRX,
|
|
ifMauTimeSyncDelayTXmax,
|
|
ifMauTimeSyncDelayTXmin,
|
|
ifMauTimeSyncDelayRXmax,
|
|
ifMauTimeSyncDelayRXmin
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance Time Sync support and delay
|
|
reporting MAUs attached to interfaces."
|
|
::= { mauModObjGrps 13 }
|
|
|
|
mauIfGrpPerPCSLaneStats OBJECT-GROUP
|
|
OBJECTS { ifMauPPLFECCorrectedBlocks,
|
|
ifMauPPLFECUncorrectableBlocks,
|
|
ifMauBIPErrorCount,
|
|
ifMauPCStoPHYLaneMapping
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Conformance Per-PCS lane statistics
|
|
reporting MAUs attached to interfaces."
|
|
::= { mauModObjGrps 14 }
|
|
|
|
-- Notification groups
|
|
|
|
rpMauNotifications NOTIFICATION-GROUP
|
|
NOTIFICATIONS { rpMauJabberTrap }
|
|
STATUS current
|
|
DESCRIPTION "Notifications for repeater MAUs."
|
|
::= { mauModNotGrps 1 }
|
|
|
|
ifMauNotifications NOTIFICATION-GROUP
|
|
NOTIFICATIONS { ifMauJabberTrap }
|
|
STATUS current
|
|
DESCRIPTION "Notifications for interface MAUs."
|
|
::= { mauModNotGrps 2 }
|
|
|
|
-- Compliance statements
|
|
|
|
mauModRpCompl2 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION "Compliance for MAUs attached to repeater
|
|
ports.
|
|
|
|
Note that compliance with this compliance
|
|
statement requires compliance with the
|
|
snmpRptrModCompl MODULE-COMPLIANCE statement of
|
|
the IEEE8023-SNMP-REPEATER-MIB defined in Clause 7."
|
|
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { mauRpGrpBasic }
|
|
|
|
GROUP mauRpGrp100Mbs
|
|
DESCRIPTION "Implementation of this optional group is
|
|
recommended for MAUs that have 100 Mb/s or
|
|
greater capability."
|
|
|
|
GROUP mauRpGrpJack
|
|
DESCRIPTION "Implementation of this optional group is
|
|
recommended for MAUs that have one or more
|
|
external jacks."
|
|
|
|
GROUP rpMauNotifications
|
|
|
|
DESCRIPTION "Implementation of this group is recommended
|
|
for MAUs attached to repeater ports."
|
|
|
|
OBJECT rpMauStatus
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
::= { mauModCompls 1 }
|
|
|
|
mauModIfCompl3 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION "Compliance for MAUs attached to interfaces.
|
|
|
|
Note that compliance with this compliance
|
|
statement requires compliance with the
|
|
ifCompliance3 MODULE-COMPLIANCE statement of the
|
|
IF-MIB (RFC 2863) and the dot3Compliance2
|
|
MODULE-COMPLIANCE statement of the
|
|
IEEE8023-EtherLike-MIB defined in Clause 10."
|
|
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { mauIfGrpBasic }
|
|
|
|
GROUP mauIfGrpHighCapacity
|
|
DESCRIPTION "Implementation of this optional group is
|
|
recommended for MAUs that have 100 Mb/s
|
|
or greater capability."
|
|
GROUP mauIfGrpHCStats
|
|
DESCRIPTION "Implementation of this group is mandatory
|
|
for MAUs that have 1000 Mb/s capacity, and
|
|
is recommended for MAUs that have 100 Mb/s
|
|
capacity."
|
|
|
|
|
|
GROUP mauIfGrpJack
|
|
DESCRIPTION "Implementation of this optional group is
|
|
recommended for MAUs that have one or more
|
|
external jacks."
|
|
GROUP mauIfGrpAutoNeg2
|
|
DESCRIPTION "Implementation of this group is mandatory
|
|
for MAUs that support managed
|
|
Auto-Negotiation."
|
|
GROUP mauIfGrpAutoNeg1000Mbps
|
|
DESCRIPTION "Implementation of this group is mandatory
|
|
for MAUs that have 1000 Mb/s or greater
|
|
capability and support managed
|
|
Auto-Negotiation."
|
|
GROUP ifMauNotifications
|
|
DESCRIPTION "Implementation of this group is recommended
|
|
for MAUs attached to interfaces."
|
|
OBJECT ifMauStatus
|
|
MIN-ACCESS read-only
|
|
DESCRIPTION "Write access is not required."
|
|
GROUP mauIfGrpFEC
|
|
DESCRIPTION "Implementation of this optional group is
|
|
recommended for MAUs that incorporate FEC."
|
|
GROUP mauIfGrpSNR
|
|
DESCRIPTION "Implementation of this optional group is
|
|
recommended for MAUs that report SNR operating
|
|
margin."
|
|
GROUP mauIfGrpEEE
|
|
DESCRIPTION "Implementation of this group is
|
|
mandatory for MAUs that support EEE."
|
|
GROUP mauIfGrpTimeSync
|
|
DESCRIPTION "Implementation of this group is
|
|
mandatory for MAUs that support Time Sync"
|
|
GROUP mauIfGrpPerPCSLaneStats
|
|
DESCRIPTION "Implementation of this group is
|
|
mandatory for MAUs that report per-PCS lane
|
|
statistics."
|
|
::= { mauModCompls 2 }
|
|
|
|
END |