Observium_CE/mibs/mrv/DC-OAMM-MIB

396 lines
13 KiB
Plaintext

DC-OAMM-MIB DEFINITIONS ::= BEGIN
-- The OAM MANAGEMENT COMPONENT MIB
-- PRODUCT-SHORT-NAME OAMM
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
enterprises, Unsigned32,
Integer32
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
TEXTUAL-CONVENTION,
TruthValue, RowStatus
FROM SNMPv2-TC
MjStatus,
AdminStatus,
OperStatus,
BaseOperStatus
FROM DC-MASTER-TC;
-- The Mib Identifier for the set of MIBs defined in this asn1 file.
oammMib MODULE-IDENTITY
LAST-UPDATED "201412210000Z" -- December 21, 2014
ORGANIZATION "MRV Communications."
CONTACT-INFO
"For technical support, please contact your service channel"
DESCRIPTION "DC-OAM Management component MIB."
-- Revision history
REVISION "201412210000Z" -- December 21, 2014
DESCRIPTION
"Initial edition."
::= { opx 14 }
-- The value 112 matches the PRD_OAMM constant.
nbase OBJECT IDENTIFIER ::= { enterprises 629 }
opx OBJECT IDENTIFIER ::= { nbase 10 }
-- Top level components of this MIB module.
oammObjects OBJECT IDENTIFIER ::= { oammMib 1 } -- OAMM tables
oammConformance OBJECT IDENTIFIER ::= { oammMib 2 }
-------------------------------------------------------------------------------
--
-- Textual conventions
--
OammMjIfId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION "The type of interface to which a join applies."
SYNTAX INTEGER {
ifAtgI3(696844288), -- Interface IF_ATG_I3
ifAtgFri(697761792), -- Interface IF_ATG_FRI
ifAtgBfdi(1518338048), -- Interface IF_ATG_BFDI
ifAtgLpi(1904214016), -- Interface IF_ATG_LPI
ifAtgPmi(1988100096) -- Interface IF_ATG_PMI
}
-------------------------------------------------------------------------------
--
-- DC-OAM Management component Entity Table.
--
-- This is the top-level MIB for DC-OAM Management component. It controls creation and global
-- configuration of DC-OAM Management component.
--
oammEntTable OBJECT-TYPE
-- FAMILY-SHORT-NAME OAMM_ENT
SYNTAX SEQUENCE OF OammEntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry in this table represents a DC-OAM Management component entity."
::= { oammObjects 1 }
oammEntEntry OBJECT-TYPE
SYNTAX OammEntEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry represents a DC-OAM Management component entity."
INDEX { oammEntApplIndex }
::= { oammEntTable 1 }
OammEntEntry ::= SEQUENCE {
oammEntApplIndex Unsigned32,
oammEntRowStatus RowStatus,
oammEntAdminStatus AdminStatus,
oammEntOperStatus BaseOperStatus,
oammEntEnableTrapSupport TruthValue,
oammEntFriBufferPoolSize Integer32,
oammEntRescheduleLimit Integer32
}
oammEntApplIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies a DC-OAM Management component entity."
::= { oammEntEntry 1 }
oammEntRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The row status for this DC-OAM Management component Entity Table entry, used to
create and destroy table entries."
::= { oammEntEntry 2 }
oammEntAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of this DC-OAM Management component entity, used to
activate and deactivate DC-OAM Management component."
DEFVAL { adminStatusUp }
::= { oammEntEntry 3 }
oammEntOperStatus OBJECT-TYPE
SYNTAX BaseOperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current operational status of this DC-OAM Management component entity."
::= { oammEntEntry 4 }
oammEntEnableTrapSupport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Set this object to 'true' to enable trap support in DC-OAM Manager."
DEFVAL { false }
::= { oammEntEntry 5 }
oammEntFriBufferPoolSize OBJECT-TYPE
SYNTAX Integer32 (1..200)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The size of the FRI buffer pool.
This determines the maximum number of buffers that can
exist at once for the FRI pool. DC-OAM Manager does not
use pre-allocated pools, so the maximum number of buffers
is also limited by memory availability, and so this number
does not relate directly to memory usage.
Buffer pools provide flow control, which is useful in
ensuring efficient operation of the overall system.
This field is not suitable for network administrators.
This field cannot be changed after initial creation of the
entity. Instead of changing this field, create a new
DC-OAM Manager entity with the new value and destroy the
old entity."
DEFVAL { 1 }
::= { oammEntEntry 6 }
oammEntRescheduleLimit OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The maximum number of different objects that can be
processed in a single schedule.
When subcomponents are scheduled by receipt of an IPS or a
timer pop, that IPS can cause more work than can be
performed in a reasonable time without blocking the
N-BASE. Subcomponents handle this by breaking off
processing when they hit a processing limit.
Higher values increase the processing efficiency of
DC-OAM Manager instances, but can cause the scheduler to
be blocked for excessive periods, causing timers to pop
late. Lower values have the reverse effects.
This field is not suitable for network administrators.
This field cannot be changed after initial creation of the
entity. Instead of changing this field, create a new
DC-OAM Manager entity with the new value and destroy the
old entity."
DEFVAL { 1000 }
::= { oammEntEntry 7 }
-------------------------------------------------------------------------------
--
-- DC-OAM Management component Master Join Table.
--
-- This table controls which entities DC-OAM Management component should join to as
-- master. Each join is represented by a row in this table. The status of
-- each join is represented by a read-only object within each row.
--
oammMjTable OBJECT-TYPE
-- FAMILY-SHORT-NAME OAMM_MJ
SYNTAX SEQUENCE OF OammMjEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This table controls which entities the DC-OAM Management component should join to
as master. Each join is represented by a row
in this table. The status of each join is represented
by a read-only object within each row.
DC-MPLS OAM Manager requires a single join of type
AMB_OAMM_MJ_I3 in order for it to go operStatusUp.
Additional joins must be programmed in order to support
specific DC-MPLS OAM manager function.
- A single join of type AMB_OAMM_MJ_FRI is required if
DC-MPLS OAM Manager is to report faults status as
determined by OAM function.
- One or more joins of type AMB_OAMM_MJ_BFDI must be
programmed to enable DC-MPLS OAM Manager to intitiate BFD
sessions.
- One or more joins of type AMB_OAMM_MJ_LPI must be
programmed to enable DC-MPLS OAM Manager to intitiate LSP
Ping transactions.
- One or more joins of type AMB_OAMM_MJ_PMI must be
programmed to enable DC-MPLS OAM Manager to intitiate
Performance Monitoring sessions."
::= { oammObjects 2 }
oammMjEntry OBJECT-TYPE
SYNTAX OammMjEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Represents a join for which DC-OAM Management component master."
INDEX { oammMjApplIndex,
oammMjInterfaceId,
oammMjPartnerType,
oammMjPartnerIndex,
oammMjSubIndex }
::= { oammMjTable 1 }
OammMjEntry ::= SEQUENCE {
oammMjApplIndex Unsigned32,
oammMjInterfaceId OammMjIfId,
oammMjPartnerType Unsigned32,
oammMjPartnerIndex Unsigned32,
oammMjSubIndex Unsigned32,
oammMjRowStatus RowStatus,
oammMjAdminStatus AdminStatus,
oammMjOperStatus OperStatus,
oammMjJoinStatus MjStatus
}
oammMjApplIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies a DC-OAM Management component entity."
::= { oammMjEntry 1 }
oammMjInterfaceId OBJECT-TYPE
SYNTAX OammMjIfId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the interface required of this master join."
::= { oammMjEntry 2 }
oammMjPartnerType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Identifies the type of entity to join to. This is only used
if oammMjInterfaceId is AMB_OAMM_MJ_LPI, in which case it must
be set to one of AMB_OAMM_TYPE_LSP_PING_PROTOCOL or
AMB_OAMM_TYPE_QUERY_LSP_RSP depending on whether the partner
will be providing LSP Ping Protocol function or processing
Query LSP messages. For all other values of
oammMjInterfaceId, this field must be set to
AMB_OAMM_TYPE_NONE."
::= { oammMjEntry 3 }
oammMjPartnerIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The entity index of the partner to join to."
::= { oammMjEntry 4 }
oammMjSubIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "This index field is currently unused and MUST be set to zero."
::= { oammMjEntry 5 }
oammMjRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The row status for this DC-OAM Management component Master Join Table
entry, used to create and destroy table entries."
::= { oammMjEntry 6 }
oammMjAdminStatus OBJECT-TYPE
SYNTAX AdminStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "The administrative status of this master join, used
to start and stop the join."
DEFVAL { adminStatusUp }
::= { oammMjEntry 7 }
oammMjOperStatus OBJECT-TYPE
SYNTAX OperStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current operational status of this master join."
::= { oammMjEntry 8 }
oammMjJoinStatus OBJECT-TYPE
SYNTAX MjStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The status of the master join."
::= { oammMjEntry 9 }
------------------------------------------------------------------
-- Module Conformance Statement
------------------------------------------------------------------
oammGroups
OBJECT IDENTIFIER ::= { oammConformance 1 }
oammCompliances
OBJECT IDENTIFIER ::= { oammConformance 2 }
--
-- Full Compliance
--
oammModuleFullCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The Module is implemented with support
for read-create. In other
words, both monitoring and configuration
are available when using this MODULE-COMPLIANCE."
MODULE -- this module
MANDATORY-GROUPS { oammGeneralGroup
}
::= { oammCompliances 1 }
--
-- Read-Only Compliance
--
oammModuleReadOnlyCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The Module is implemented with support
for read-only. In other words, only monitoring
is available by implementing this MODULE-COMPLIANCE."
MODULE -- this module
MANDATORY-GROUPS { oammGeneralGroup
}
::= { oammCompliances 2 }
-- units of conformance
oammGeneralGroup OBJECT-GROUP
OBJECTS {
oammEntRowStatus,
oammEntAdminStatus,
oammEntOperStatus,
oammEntEnableTrapSupport,
oammEntFriBufferPoolSize,
oammEntRescheduleLimit,
oammMjRowStatus,
oammMjAdminStatus,
oammMjOperStatus,
oammMjJoinStatus
}
STATUS current
DESCRIPTION
"Objects that apply to all MPLS MP MIB implementations."
::= { oammGroups 1 }
-------------------------------------------------------------------------------
END