5287 lines
220 KiB
Plaintext
5287 lines
220 KiB
Plaintext
-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 1997.
|
|
--
|
|
-- LaserJet 5 Printer Model Specific MIB.
|
|
--
|
|
-- Generated on August 4, 1997.
|
|
--
|
|
-- Company names and product names mentioned herein may be
|
|
-- trademarks, and/or registered trademarks of their respective
|
|
-- companies.
|
|
--
|
|
-- For interal and external use.
|
|
--
|
|
-- This MIB describes all the printer model specific
|
|
-- objects suppported by the LaserJet 5 printer
|
|
-- when networked connected using a JetDirect print
|
|
-- server.
|
|
--
|
|
-- The following MIB also contain objects supported
|
|
-- by a JetDirect connected LaserJet 5 printer:
|
|
--
|
|
-- rfc 1213 MIB II
|
|
--
|
|
-- This MIB complies with the following RFCs:
|
|
--
|
|
-- rfc 1157 Simple Network Management Protocol
|
|
-- rfc 1155 Structure of Management Information
|
|
--
|
|
-- Notes:
|
|
--
|
|
-- 1) At the time this MIB was published, a
|
|
-- defect existed where the printer would not correctly
|
|
-- handle an SNMP get next request. The printer
|
|
-- behavior is correct for tabular objects, but not
|
|
-- scalar objects. For example, energy-star, sleep-mode,
|
|
-- and on-off-line are all scalars with OIDS:
|
|
--
|
|
-- energy-star { dm 1 1 1 1 }
|
|
-- sleep-mode { dm 1 1 1 2 }
|
|
-- on-off-line { dm 1 2 2 5 }
|
|
--
|
|
-- These three objects are the first three objects supported
|
|
-- under the dm tree.
|
|
--
|
|
-- The printer operation (using OpenView tools as an
|
|
-- example) is:
|
|
--
|
|
-- snmpnext hpb18207 .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2.0
|
|
--
|
|
-- with a reply of:
|
|
--
|
|
-- hp.nm.hpsystem.net-peripheral.netdm.dm.device.system.status-system.
|
|
-- on-off-line.0 : INTEGER: eOnline
|
|
--
|
|
-- which the printer handles correctly.
|
|
--
|
|
-- However, if the zero is left off the end, then the printer operation
|
|
-- is:
|
|
--
|
|
-- snmpnext hpb18207 .1.3.6.1.4.1.11.2.3.9.4.2.1.1.1.2
|
|
--
|
|
-- with a reply of:
|
|
--
|
|
-- hp.nm.hpsystem.net-peripheral.netdm.dm.device.system.status-system.
|
|
-- on-off-line.0 : INTEGER: eOnline
|
|
--
|
|
-- which is incorrect. The object that should have been returned is
|
|
-- the energy-star object, not the on-off-line object.
|
|
--
|
|
-- Since the OpenView MIB Browser uses the get next command in an
|
|
-- attempt to retrieve all the supported objects under the specified OID
|
|
-- =======================
|
|
-- (object identifier) and the printer returns an object that is not under
|
|
-- the specified OID, the MIB Browser assumes there are no objects
|
|
-- supported under the specified OID and reports "no value (s) returned for
|
|
-- query".
|
|
--
|
|
-- If you use an SNMP tool other than OpenView MIB Browser to do a get,
|
|
-- the printer properly responds.
|
|
--
|
|
-- Retrieving tables using the OpenView MIB Browser works fine. Only
|
|
-- retrieving scalar objects fails.
|
|
--
|
|
-- 2) Proprietary Objects containing a string which are defined in this
|
|
-- MIB use the first two bytes to hold the symbol set used to encode
|
|
-- the string. The Roman-8 symbol set has a hex encoding of 0x0115.
|
|
-- Other symbol sets are listed in the PCL 5 Comparison Guide in table
|
|
-- C-1 Symbol Set Values. Standard Printer MIB (prt...objects) and
|
|
-- Host Resources MIB (hr...objects) strings do not contain symbol
|
|
-- set information.
|
|
--
|
|
-- 3) Some of the objects included are only supported if an accessory
|
|
-- is installed. These accessories include:
|
|
-- MIO based accessories
|
|
-- SIMM based accessories
|
|
-- AT hard disk
|
|
-- Paper handling accessories
|
|
-- Adobe PostScript accessory
|
|
--
|
|
--
|
|
LaserJet-5-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
enterprises FROM SNMPv2-SMI,
|
|
DisplayString FROM SNMPv2-TC;
|
|
|
|
hp OBJECT IDENTIFIER ::= { enterprises 11 }
|
|
nm OBJECT IDENTIFIER ::= { hp 2 }
|
|
hpsystem OBJECT IDENTIFIER ::= { nm 3 }
|
|
net-peripheral OBJECT IDENTIFIER ::= { hpsystem 9 }
|
|
netdm OBJECT IDENTIFIER ::= { net-peripheral 4 }
|
|
dm OBJECT IDENTIFIER ::= { netdm 2}
|
|
|
|
device OBJECT IDENTIFIER ::= { dm 1 }
|
|
system OBJECT IDENTIFIER ::= { device 1 }
|
|
settings-system OBJECT IDENTIFIER ::= { system 1 }
|
|
status-system OBJECT IDENTIFIER ::= { system 2 }
|
|
background-message OBJECT IDENTIFIER ::= { status-system 37 }
|
|
background-message1 OBJECT IDENTIFIER ::= { background-message 1 }
|
|
id OBJECT IDENTIFIER ::= { system 3 }
|
|
interface OBJECT IDENTIFIER ::= { system 4 }
|
|
simm OBJECT IDENTIFIER ::= { interface 1 }
|
|
simm1 OBJECT IDENTIFIER ::= { simm 1 }
|
|
simm2 OBJECT IDENTIFIER ::= { simm 2 }
|
|
simm3 OBJECT IDENTIFIER ::= { simm 3 }
|
|
simm4 OBJECT IDENTIFIER ::= { simm 4 }
|
|
mio OBJECT IDENTIFIER ::= { interface 3 }
|
|
mio1 OBJECT IDENTIFIER ::= { mio 1 }
|
|
phd OBJECT IDENTIFIER ::= { interface 5 }
|
|
phd1 OBJECT IDENTIFIER ::= { phd 1 }
|
|
test OBJECT IDENTIFIER ::= { system 5 }
|
|
job OBJECT IDENTIFIER ::= { system 6 }
|
|
settings-job OBJECT IDENTIFIER ::= { job 1 }
|
|
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
|
|
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
|
|
job-info OBJECT IDENTIFIER ::= { job 5 }
|
|
job-info-attribute OBJECT IDENTIFIER ::= { job-info 23 }
|
|
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
|
|
io OBJECT IDENTIFIER ::= { source-subsystem 1 }
|
|
settings-io OBJECT IDENTIFIER ::= { io 1 }
|
|
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
|
|
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
|
|
settings-pdl OBJECT IDENTIFIER ::= { pdl 1 }
|
|
status-pdl OBJECT IDENTIFIER ::= { pdl 2 }
|
|
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
|
|
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
|
|
pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 }
|
|
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
|
|
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
|
|
settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 }
|
|
intray OBJECT IDENTIFIER ::= { print-engine 3 }
|
|
settings-intray OBJECT IDENTIFIER ::= { intray 1 }
|
|
intrays OBJECT IDENTIFIER ::= { intray 3 }
|
|
intray1 OBJECT IDENTIFIER ::= { intrays 1 }
|
|
intray2 OBJECT IDENTIFIER ::= { intrays 2 }
|
|
intray3 OBJECT IDENTIFIER ::= { intrays 3 }
|
|
intray4 OBJECT IDENTIFIER ::= { intrays 4 }
|
|
marking-agent OBJECT IDENTIFIER ::= { print-engine 5 }
|
|
settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 }
|
|
imaging OBJECT IDENTIFIER ::= { print-engine 6 }
|
|
tables OBJECT IDENTIFIER ::= { device 7 }
|
|
channel-table OBJECT IDENTIFIER ::= { tables 2 }
|
|
channel-entry OBJECT IDENTIFIER ::= { channel-table 1 }
|
|
file-system OBJECT IDENTIFIER ::= { system 10 }
|
|
settings-file-system OBJECT IDENTIFIER ::= { file-system 1 }
|
|
status-file-system OBJECT IDENTIFIER ::= { file-system 2 }
|
|
file-systems OBJECT IDENTIFIER ::= { file-system 3 }
|
|
file-system2 OBJECT IDENTIFIER ::= { file-systems 2 }
|
|
resource-manager OBJECT IDENTIFIER ::= { system 12 }
|
|
mass-storage-resources OBJECT IDENTIFIER ::= { resource-manager 3 }
|
|
remote-procedure-call OBJECT IDENTIFIER ::= { system 13 }
|
|
settings-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 1 }
|
|
status-rpc OBJECT IDENTIFIER ::= { remote-procedure-call 2 }
|
|
rpc-services OBJECT IDENTIFIER ::= { remote-procedure-call 3 }
|
|
nfs-server OBJECT IDENTIFIER ::= { rpc-services 2 }
|
|
settings-nfs-server OBJECT IDENTIFIER ::= { nfs-server 1 }
|
|
status-nfs-server OBJECT IDENTIFIER ::= { nfs-server 2 }
|
|
rpc-bind OBJECT IDENTIFIER ::= { rpc-services 3 }
|
|
settings-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 1 }
|
|
status-rpc-bind OBJECT IDENTIFIER ::= { rpc-bind 2 }
|
|
xport-interface OBJECT IDENTIFIER ::= { system 14 }
|
|
status-xip OBJECT IDENTIFIER ::= { xport-interface 2 }
|
|
hrm OBJECT IDENTIFIER ::= { dm 3 }
|
|
hrStorage OBJECT IDENTIFIER ::= { hrm 2 }
|
|
hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 }
|
|
hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 }
|
|
hrDevice OBJECT IDENTIFIER ::= { hrm 3 }
|
|
hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 }
|
|
hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 }
|
|
hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 }
|
|
hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 }
|
|
printmib OBJECT IDENTIFIER ::= { dm 2 }
|
|
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
|
|
prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 }
|
|
prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 }
|
|
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
|
|
prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 }
|
|
prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 }
|
|
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
|
|
prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 }
|
|
prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 }
|
|
prtStorageRefTable OBJECT IDENTIFIER ::= { prtGeneral 2 }
|
|
prtStorageRefEntry OBJECT IDENTIFIER ::= { prtStorageRefTable 1 }
|
|
prtDeviceRefTable OBJECT IDENTIFIER ::= { prtGeneral 3 }
|
|
prtDeviceRefEntry OBJECT IDENTIFIER ::= { prtDeviceRefTable 1 }
|
|
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
|
|
prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 }
|
|
prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 }
|
|
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
|
|
prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 }
|
|
prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 }
|
|
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
|
|
prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 }
|
|
prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 }
|
|
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
|
|
prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 }
|
|
prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 }
|
|
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
|
|
prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 }
|
|
prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 }
|
|
prtChannel OBJECT IDENTIFIER ::= { printmib 14 }
|
|
prtChannelTable OBJECT IDENTIFIER ::= { prtChannel 1 }
|
|
prtChannelEntry OBJECT IDENTIFIER ::= { prtChannelTable 1 }
|
|
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
|
|
prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 }
|
|
prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 }
|
|
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
|
|
prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 }
|
|
prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 }
|
|
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
|
|
prtConsoleLightTable OBJECT IDENTIFIER ::= { prtConsoleLights 6 }
|
|
prtConsoleLightEntry OBJECT IDENTIFIER ::= { prtConsoleLightTable 1 }
|
|
prtAlert OBJECT IDENTIFIER ::= { printmib 18 }
|
|
prtAlertTable OBJECT IDENTIFIER ::= { prtAlert 1 }
|
|
prtAlertEntry OBJECT IDENTIFIER ::= { prtAlertTable 1 }
|
|
|
|
|
|
energy-star OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the Energy Star sleep value. If the
|
|
value is greater than zero, then the device will go into
|
|
energy saving sleep mode after the print engine has been
|
|
idle for the number of seconds specified by this object.
|
|
A value of zero means Energy Star is disabled and the
|
|
device will not go to sleep based on print engine idle
|
|
time. The value must be non-negative.
|
|
Additional information:
|
|
Returns or changes the Energy Star sleep value.
|
|
The device will go into energy saving sleep
|
|
mode after the print engine has been idle for
|
|
the number of seconds specified by this
|
|
object.
|
|
|
|
LaserJet 5 supports values of 0, 900, 1800,
|
|
3600, 7200, and 10800. A value of 0 means
|
|
never go to sleep based on print engine idle
|
|
time. Setting to an unsupported value causes
|
|
the printer to substitute a value (listed
|
|
below) and to return <noError>
|
|
status.
|
|
The values are as follow:
|
|
<=0 snap to 0
|
|
>=1 and <=1349 snap to 900 (15 minutes)
|
|
>=1350 and <=2699 snap to 1800 (30 minutes)
|
|
>=2700 and <=5399 snap to 3600 (1 hour)
|
|
>=5400 and <=8999 snap to 7200 (2 hours)
|
|
>=9000 snap to 10800 (3 hours)"
|
|
::= { settings-system 1 }
|
|
|
|
|
|
sleep-mode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns eTrue if the device is in energy saving sleep
|
|
mode, otherwise returns eFalse. Setting SLEEP-MODE to
|
|
eFalse causes the device to wake up, if it is in sleep
|
|
mode. Setting SLEEP-MODE to eTrue causes the device to
|
|
go into sleep mode.
|
|
Additional information:
|
|
Setting this object to eTrue while the printer
|
|
is awake will not change the printer's current state
|
|
and will return <genErr>
|
|
status.
|
|
Setting to eTrue while printer is already in
|
|
the Sleep Mode will not change the printer's
|
|
current state and will return <noError> status.
|
|
Setting to eFalse while printer is already awake
|
|
will not change the printer's current state and will
|
|
return <noError> status. "
|
|
::= { settings-system 2 }
|
|
|
|
|
|
on-off-line OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOnline(1),
|
|
eOffline(2),
|
|
eOfflineAtEndOfJob(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"To bring the PDL processing sub-system on or off line.
|
|
If the device is a printer, then the printer does not
|
|
process print job data when the printer is off line.
|
|
PML communication persists.
|
|
Additional information:
|
|
When the printer is in the Offline state,
|
|
printing will stop as soon as possible (no more sheets
|
|
of media are pulled from input trays). The I/O
|
|
is taken offline also.
|
|
|
|
Setting to eOnline has the following affect:
|
|
Printer will immediately go to or remain in the Online
|
|
state; <noError> status is returned.
|
|
If the printer's current state
|
|
is Offline with a pending error condition that
|
|
prevents the printer from going to the Online
|
|
state, the printer will remain in the Offline state;
|
|
<genErr> status is returned
|
|
|
|
Setting to eOffline has the following affect:
|
|
Printer will immediately go to or remain in the
|
|
Offline state; <noError> status is returned.
|
|
If pages are being printed, those pages will complete
|
|
with the printer in the Offline state.
|
|
|
|
Setting to eOfflineAtEndOfJob has the following
|
|
affect:
|
|
If not in a job or already in the Offline state, the
|
|
printer will immediately go to or remain in the
|
|
Offline state; <noError> status is returned.
|
|
If in a job and the current state is Online, the
|
|
printer will remain in the Online state, with the
|
|
value of this object as eOfflineAtEndOfJob, until the
|
|
end of the job; <noError> status is returned. At the end of
|
|
the job, the printer goes to the Offline state and the
|
|
value of this object becomes eOffline.
|
|
Setting this object to eOffline or eOnline before the
|
|
end of the job causes the action for that value to be
|
|
taken immediately."
|
|
::= { status-system 5 }
|
|
|
|
|
|
continue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInitiateAction(1)
|
|
}
|
|
ACCESS write-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A device can support a class of errors called
|
|
continuable errors. When a continuable error is
|
|
encountered, the device requires a continue event to
|
|
occur before the device will continue operation. One
|
|
continue event is setting the CONTINUE object to
|
|
eInitiateAction. Devices can support other continue
|
|
events, like auto-continue. A continue event causes the
|
|
continuable error to be acknowledged, thus allowing the
|
|
device to continue. Each device needs to list the
|
|
continuable errors. If the device doesn't currently
|
|
have an unacknowledged continuable error, the response
|
|
will contain <genErr>.
|
|
Additional information:
|
|
If LaserJet 5 doesn't currently have an
|
|
unacknowledged continuable error, the
|
|
response will contain <noError> status. The following is
|
|
a list of continuable errors in LaserJet 5:
|
|
Toner Low
|
|
Manually feed yy
|
|
Tray X Load yy
|
|
PJL OPMSG
|
|
PJL STMSG
|
|
20 Insufficient Memory, Press Go Key
|
|
21 Page Too Complex, Press Go Key
|
|
22 Serial IO Error, Press Go Key
|
|
22 Parallel IO Error, Press Go Key
|
|
22 HPMIO Error, Press Go Key
|
|
40 Bad Serial Data Format, Press Go Key
|
|
40 HPMIO Error, Press Go Key
|
|
41.x Printer Error, Press Go Key
|
|
55 Printer Error, Press Go Key
|
|
68 NVRAM Full, Settings Not Saved
|
|
68 NVRAM Error, Settings Not Saved
|
|
Incompatible Tray3 Installed
|
|
Incompatible Envelope Feeder Installed "
|
|
::= { status-system 6 }
|
|
|
|
|
|
auto-continue OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates if the device will automatically continue
|
|
after encountering a continuable error. If AUTO-
|
|
CONTINUE is set to eOn, the device will automatically
|
|
generate continue event to acknowledge continuable
|
|
errors. If AUTO-CONTINUE is set to eOff, then some
|
|
other continue event will have to acknowledge the
|
|
continuable error.
|
|
Additional information:
|
|
If the printer is not idle, the new value may not take effect
|
|
until a job boundary is reached.
|
|
If a get is done on this object before the job boundary is reached, the
|
|
value last set will be returned. If this is eOn the device displays an
|
|
error message and goes offline for ten seconds. After ten seconds the
|
|
printer automatically returns to the online state. If this is eOff then
|
|
the device displays an error message and goes offline and remains offline
|
|
until the operator presses the GO key."
|
|
::= { status-system 7 }
|
|
|
|
|
|
background-status-msg-line1-part1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The string displayed on the device's front panel in
|
|
place of the printer's built-in background status
|
|
string. An example built-in background status string is
|
|
'00 READY'.
|
|
Additional information:
|
|
This object allows a message to be displayed when
|
|
it is the highest priority message. Setting this
|
|
objedct does not guarantee the message will be
|
|
displayed; and reading it returns the value last
|
|
written, not the currently displayed message (use
|
|
prtConsoleDisplayBufferText to read the
|
|
display).
|
|
The priority assigned for displaying this message
|
|
is one lower than the PJL RDYMSG.
|
|
To clear the message, write a null string to this
|
|
object.
|
|
While the object prtConsoleLocalization controls the
|
|
localization and symbol set usage of printer generated messages, this
|
|
object's message is displayed using the symbol set
|
|
specified with the string. The default symbol set is Roman-8; additional
|
|
legal symbol sets are ISOLatin5, ISOLatin2. "
|
|
::= { background-message1 1 }
|
|
|
|
|
|
model-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Identifies the device model name (e.g. ''DeskJet
|
|
1200C''). The string is as specific as possible.
|
|
Capitalization and spacing should match family naming
|
|
conventions. Products should note in POS if the model
|
|
name on the HP corporate price list changes but the
|
|
device reports the previous device name. If the model
|
|
name changes based on the installed options, the POS
|
|
should indicate if only the base model name is returned,
|
|
or if the device senses the installed options and
|
|
returns the correct model name. If possible, encode the
|
|
model name in a symbol set (like Roman-8) that matches
|
|
the ASCII character set and limit the characters used to
|
|
ASCII characters.
|
|
Additional information:
|
|
The value of this object does not change based on
|
|
the installed options.
|
|
Since the value of this object is frequently used in displaying a list of
|
|
printers, it is kept relatively short in case systems have limited width
|
|
for their display area."
|
|
::= { id 2 }
|
|
|
|
|
|
serial-number OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Identifies the serial number for the device. If the
|
|
SERIAL-NUMBER object is set by the user, then setting
|
|
the object does not need to be protected. If the
|
|
SERIAL-NUMBER object is set at the factory, then the
|
|
SERVICE-PASSWORD object must be set correctly before the
|
|
SERIAL-NUMBER object is writable. If this is a writable
|
|
object, the POS should indicate the maximum supported
|
|
string length. If possible, encode the serial number in
|
|
a symbol set (like Roman-8) that matches the ASCII
|
|
character set and limit the characters used to ASCII
|
|
characters.
|
|
Additional information:
|
|
The format of the LaserJet 5 serial number is:
|
|
axxyyyzzzzz
|
|
where: a = S (always)
|
|
xx = 46 (the entity #)
|
|
yyy = 0..9 & A..Z (the product code specific to LaserJet 5, probably 01L)
|
|
zzzzz = 0..9 & A..Z omitting I,O,U (sequentially assigned alpha/num base
|
|
33 numbers)
|
|
So it will typically look like S4601LXXXXX
|
|
This value IS AFFECTED BY NVRAM resets, it is set to the default value of
|
|
S4601LXXXXX, when a NVRAM init is done."
|
|
::= { id 3 }
|
|
|
|
|
|
device-name OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"User defined device name. The POS should indicate the
|
|
maximum supported string length. If the user entered
|
|
string is too long, the device will store as much as
|
|
possible and will return the <noError>.
|
|
|
|
Additional information:
|
|
The maximum supported string length is 32
|
|
characters. If the user entered string is too long,
|
|
the device will store the first 32 characters and will
|
|
return the <noError> status."
|
|
::= { id 10 }
|
|
|
|
|
|
device-location OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"User defined device location. The POS should indicate
|
|
the maximum supported string length. If the user
|
|
entered string is too long, the device will store as
|
|
much as possible and will return the <noError>.
|
|
|
|
Additional information:
|
|
The maximum supported string length is 16
|
|
characters. If the user entered string is too long,
|
|
the device will store the first 16 characters and will
|
|
return the <noError> status."
|
|
::= { id 11 }
|
|
|
|
|
|
asset-number OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"User defined asset number. The POS should indicate the
|
|
maximum supported string length. If the user entered
|
|
string is too long, the device will store as much as
|
|
possible and will return the <noError>.
|
|
|
|
Additional information:
|
|
The maximum supported string length is 8
|
|
characters. If the user entered string is too long,
|
|
the device will store the first 8 characters and will
|
|
return the <noError> status."
|
|
::= { id 12 }
|
|
|
|
|
|
simm1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5),
|
|
eFlashMemory(7),
|
|
eRamRom(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 1.
|
|
eEmpty means the device did not detect any option
|
|
installed in the interface slot.
|
|
eUnknown means the device doesn't recognize the
|
|
installed option.
|
|
eUnSupported means the device recognizes the installed
|
|
option, but does not support the option.
|
|
eReadOnlyMemory means the installed option contains
|
|
ROM Ics.
|
|
eVolatileRandomAccessMemory means the installed option
|
|
contains RAM ICs that loose data when the power is
|
|
turned off.
|
|
eNonVolatileRandomAccessMemory means that the
|
|
installed option contains RAM ICs that do not loose data
|
|
when the power is turned off.
|
|
eFlashMemory means that the installed option contains
|
|
a type of non-volatile RAM that needs to be erased
|
|
before it can be written.
|
|
eDiskDrive means the installed option contains a disk
|
|
drive. eRamRom means the installed option contains both
|
|
volatile random access memory and read only memory.
|
|
eInputPHD means the installed option is an input paper
|
|
handling device.
|
|
eOutputPHD means the installed option is an output
|
|
paper handling device.
|
|
eIOCard means the installed option is an I/O card.
|
|
Additional information:
|
|
eRamRom is used to denote LaserJet 5's combo simm."
|
|
::= { simm1 4 }
|
|
|
|
|
|
simm1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 1. The capacity is dependent on
|
|
the type of option, as indicated by the SIMM1-TYPE
|
|
object. This object has no meaning if the installed
|
|
option type is eUnknown or eReadOnlyMemory. This object
|
|
contains the size, in bytes, if the installed option
|
|
type is eVolatileRandomAccessMemory,
|
|
eNonVolatileRandomAccessMemory, eFlashMemory, or
|
|
eDiskDrive. If the type of the installed option is
|
|
eRamRom, this object contains the size, in bytes, of the
|
|
random access memory. If the type of the installed
|
|
option is eInputPHD, the capacity indicates the number
|
|
of input trays supported by the installed option. If
|
|
the type of the installed option is eOutputPHD, the
|
|
capacity indicates the number of output bins supported
|
|
by the installed option. If the type of the installed
|
|
option is eIOCard, the capacity indicates the number of
|
|
logical I/O ports supported by the I/O card.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM1-TYPE type is
|
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
|
For eRamRom only the size of the Ram portion of the SIMM
|
|
is returned."
|
|
::= { simm1 5 }
|
|
|
|
|
|
simm2-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5),
|
|
eFlashMemory(7),
|
|
eRamRom(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 2. See SIMM1-TYPE for a description.
|
|
Additional information:
|
|
eRamRom is used to denote LaserJet 5's combo simm."
|
|
::= { simm2 4 }
|
|
|
|
|
|
simm2-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 2. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM2-TYPE type is
|
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
|
For eRamRom only the size of the Ram portion of the
|
|
SIMM is returned."
|
|
::= { simm2 5 }
|
|
|
|
|
|
simm3-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5),
|
|
eFlashMemory(7),
|
|
eRamRom(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 3. See SIMM1-TYPE for a description."
|
|
::= { simm3 4 }
|
|
|
|
|
|
simm3-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 3. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM3-TYPE type is
|
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
|
For eRamRom only the size of the Ram portion of the
|
|
simm is returned."
|
|
::= { simm3 5 }
|
|
|
|
|
|
simm4-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eUnknown(2),
|
|
eUnSupported(3),
|
|
eReadOnlyMemory(4),
|
|
eVolatileRandomAccessMemory(5),
|
|
eFlashMemory(7),
|
|
eRamRom(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
SIMM slot 4. See SIMM1-TYPE for a description.
|
|
Additional information:
|
|
eRamRom is used to denote LaserJet 5's combo simm."
|
|
::= { simm4 4 }
|
|
|
|
|
|
simm4-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the SIMM
|
|
installed in SIMM slot 4. See SIMM1-CAPACITY for a
|
|
description.
|
|
Additional information:
|
|
Returns an indication of the capacity of the
|
|
installed option in bytes. This object is not
|
|
supported unless the SIMM4-TYPE type is
|
|
eVolatileRandomAccessMemory, eRamRom, or eFlashMemory.
|
|
For eRamRom only the size of the Ram portion of the
|
|
SIMM is returned."
|
|
::= { simm4 5 }
|
|
|
|
|
|
mio1-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of the
|
|
I/O card installed in MIO interface 1. May include
|
|
serial number and firmware revision.
|
|
Additional information:
|
|
The format of the string returned is determined by
|
|
the manufacturer of the MIO card. There is no standard for content of the
|
|
string."
|
|
::= { mio1 3 }
|
|
|
|
|
|
mio1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eIOCard(12)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
MIO interface 1. See SIMM1-TYPE for an explanation of
|
|
the enumerations."
|
|
::= { mio1 4 }
|
|
|
|
|
|
phd1-model OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns product information identifying the PHD device.
|
|
Example: XXXX"
|
|
::= { phd1 1 }
|
|
|
|
|
|
phd1-manufacturing-info OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns information describing the manufacture of this
|
|
particular PHD. May include serial number and firmware
|
|
revision."
|
|
::= { phd1 2 }
|
|
|
|
|
|
phd1-type OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eEmpty(1),
|
|
eInputPHD(10)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the type of option installed in
|
|
this particular SIMM interface See SIMM1-TYPE for an
|
|
explanation of the enumerations.
|
|
Additional information:
|
|
Returns an indication of whether or not the
|
|
envelope feeder is installed on the printer. A value of eEmpty means that
|
|
the envelope feeder is not installed."
|
|
::= { phd1 3 }
|
|
|
|
|
|
phd1-capacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns an indication of the capacity of the installed
|
|
option. See SIMM1-CAPACITY for an explanation of the
|
|
meaning of the value of this object.
|
|
Additional information:
|
|
The LaserJet 5 envelope feeder has a
|
|
single tray."
|
|
::= { phd1 4 }
|
|
|
|
|
|
self-test OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNotInASelfTest(1),
|
|
eNonDestructiveSelfTest(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Writing this object allows a device self test to be
|
|
started. Reading this object provides an indication
|
|
what self-test is currently executing, if any. Actual
|
|
self-test operation is device specific. A self test may
|
|
not be allowed at any arbitrary time. If the device
|
|
supports the requested self test, but can not start the
|
|
execution of the self test when requested, the device
|
|
will respond with <genErr>.
|
|
If a non-destructive self test is being started, the device
|
|
will generate a response before the self test is
|
|
completed.
|
|
RECOMMENDATION: If the device is ready (i.e. the NOT-
|
|
READY-PRINTER object does not contain any items, except
|
|
maybe being off-line) and is idle (i.e. the NOT-IDLE
|
|
object does not contain any items), this request should
|
|
always succeed. This provides a mechanism for driver
|
|
writers to always determine if the action will succeed
|
|
or not.
|
|
Additional information:
|
|
The eNonDestructiveSelfTest performs limited
|
|
testing on the printer and its attached paper handling
|
|
devices. After the self-test is complete a
|
|
configuration page is printed. The recommended
|
|
way to cause a configuration page to be printed is to
|
|
use the PRINT-INTERNAL-PAGE object.
|
|
A continuous self test cannot be started
|
|
or terminated using this OID.
|
|
|
|
The printer must be idle before it can execute a
|
|
self test. The best method to assure that the
|
|
printer is idle is to set the object ON-OFF-LINE to
|
|
eOfflineAtEndOfJob, wait for the printer to be
|
|
offline and then execute the self test. The printer
|
|
will put itself online to print the page.
|
|
|
|
When the printer is idle, setting this object to
|
|
eNonDestructiveSelfTest results in a status of <noError>
|
|
and a value of eNonDestructiveSelfTest being returned.
|
|
If the printer is not idle (whether printing an
|
|
external job, printing an internal page or running
|
|
self test), a status of
|
|
<genErr> status will be
|
|
returned with a value of eNotInASelfTest.
|
|
|
|
When the printer is idle, setting this object to
|
|
eNonDestructiveSelfTest causes the page to be
|
|
formatted and put in the printer's print
|
|
queue. Before the page is in the print queue, a
|
|
get on this object will return eNonDestructiveSelfTest
|
|
(it is currently estimated that the time to format the
|
|
page is one millisecond).
|
|
Attempting to set this object before the page has
|
|
completed being formatted and printed will cause
|
|
<genErr> status to be
|
|
returned with a value of eNotInASelfTest.
|
|
|
|
After the page is in the queue, a get on this object
|
|
will return a value of eNotInASelfTest.
|
|
Setting this object to eNonDestructiveSelfTest
|
|
before the first page has completed results in
|
|
a status of <genErr> status
|
|
with a value of eNotInASelfTest.
|
|
|
|
Likewise, if the PRINT-INTERNAL-PAGE object is set to
|
|
a valid value and that page has not printed
|
|
when this object is set to eNonDestructiveSelfTest, a
|
|
status of <genErr> status
|
|
with a value of eNotInASelfTest will be
|
|
returned until the internal page has printed."
|
|
::= { test 1 }
|
|
|
|
|
|
print-internal-page OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eNotPrintingAnInternalPage(1),
|
|
ePrintingAnUnknownInternalPage(2),
|
|
eDeviceDemoPage6FileSystemDirectoryListing(8),
|
|
ePCLDemoPage1ConfigurationPage(300),
|
|
ePCLDemoPage2(301),
|
|
ePCLFontList1(350)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Writing this object to a value other than
|
|
eNotPrintingAnInternalPage causes the device to attempt
|
|
to print an internally generated page. Reading this
|
|
object provides an indication what internally generated
|
|
page is currently being printed, if any. The actual
|
|
page is device specific. Some devices may support
|
|
continuously printing an internally generated page.
|
|
Setting this object to eNotPrintingAnInternalPage
|
|
terminates continuously printing internally generated
|
|
pages. An internally generated page may not be allowed
|
|
to be printed at any arbitrary time; under what
|
|
conditions it will succeed or fail is device specific.
|
|
If the device supports the requested page, but can not
|
|
start printing the page when requested, the device will
|
|
respond with <genErr>.
|
|
RECOMMENDATION: If the device is ready (i.e. the NOT-
|
|
READY-PRINTER object does not contain any items, except
|
|
maybe being off-line) and is idle (i.e. the NOT-IDLE
|
|
object does not contain any items), this request should
|
|
always succeed. This provides a mechanism for driver
|
|
writers to always determine if the action will succeed
|
|
or not.
|
|
Additional information:
|
|
ePCLDemoPage2 is the printer demo page.
|
|
ePCLFontList1 is the PCL typeface list.
|
|
LaserJet 5 does not support continuously printing a demo
|
|
page.
|
|
|
|
The printer must be idle before it will print an
|
|
internal page. The best method to assure that the
|
|
printer is idle is to set the object ON-OFF-LINE to
|
|
eOfflineAtEndOfJob, wait for the printer to be
|
|
offline and then print the internal page. The printer
|
|
will put itself online to print the page.
|
|
|
|
When this object is set to a valid value and the
|
|
printer is idle, the status returned is <noError> and the
|
|
value returned is ePrintingAnUnknownInternalPage. If
|
|
the printer is not idle (whether printing an external
|
|
job, printing an internal page or executing a self
|
|
test), a status of <genErr>
|
|
status will be returned with a value of
|
|
eNotPrintingAnInternalPage.
|
|
|
|
Setting this object to a valid value causes the
|
|
desired page to be formatted and put in the printer's
|
|
print queue. While the page is being formatted a get
|
|
on this object will return the value
|
|
ePrintingAnUnknownInternalPage, if
|
|
the time to format the page is long enough (it is
|
|
currently estimated that the time to format some pages
|
|
is as short as one millisecond).
|
|
Attempting to set this object before the page has
|
|
completed being formatted and printed will cause
|
|
<genErr> status to be
|
|
returned with a value of
|
|
eNotPrintingAnInternalPage.
|
|
|
|
After the page is in the queue, a get on this object
|
|
will return a value of eNotPrintingAnInternalPage.
|
|
Setting this object to cause another page to be
|
|
printed before the first page has completed results in
|
|
a status of <genErr> status
|
|
with a value of eNotPrintingAnInternalPage.
|
|
|
|
Likewise, if the SELF-TEST object is set to
|
|
eNonDestructiveSelfTest and that page has not printed
|
|
when this object is set to print a page, a status of
|
|
<genErr> status
|
|
with a value of eNotPrintingAnInternalPage will be
|
|
returned until the self test page has printed."
|
|
::= { test 2 }
|
|
|
|
|
|
clearable-warning OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2),
|
|
eJob(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or controls how the device will track clearable
|
|
warnings. A clearable warning indicates a transient
|
|
event in the device. The device will continue after the
|
|
transient event occurs. If CLEARABLE-WARNING is eOff,
|
|
the device does not track clearable warnings. If
|
|
CLEARABLE-WARNING is eOn, all clearable warnings will be
|
|
tracked until cleared (acknowledged). If CLEARABLE-
|
|
WARNING is eJob, a clearable warning generated due to an
|
|
event that occurs because of the print job being
|
|
processed will be automatically cleared when the device
|
|
has finished processing the job. Example clearable
|
|
warning events include the device altering resolution or
|
|
page protection due to memory constraints. The POS will
|
|
document what transient events are treated as clearable
|
|
warnings.
|
|
Additional information:
|
|
Sets the amount of time that a clearable warning is displayed
|
|
on the control panle. If set to eOn, the warning is displayed
|
|
until the GO key is pressed. If set to eJob, the warning is
|
|
displayed until the end of the job in which it was generated."
|
|
::= { settings-job 1 }
|
|
|
|
|
|
cancel-job OBJECT-TYPE
|
|
SYNTAX INTEGER(0..32767)
|
|
ACCESS write-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Cancels the print job whose ID matches the value written
|
|
to the CANCEL-JOB object. The host first learns the job
|
|
ID using the CURRENT-JOB-PARSING-ID command. If the
|
|
printer has completely processed the job, the printer
|
|
responds with <badValue>. If the
|
|
value of the CURRENT-JOB-PARSING-ID is smaller than the
|
|
value written to the CANCEL-JOB object, then the printer
|
|
responds with <badValue>. When
|
|
read, returns the value of the last job ID what was
|
|
canceled, or -1 to indicate no job has been canceled.
|
|
Additional information:
|
|
If the value written matches the ID of a job that is
|
|
currently being canceled (for any reason),
|
|
the printer responds with <noError>.
|
|
LaserJet 5 uses job ID's in the range of 0..32767.
|
|
Because the ID number can wrap to zero,
|
|
CURRENT-JOB-PARSING-ID may be smaller than the value
|
|
written to this object; when this occurs, no error
|
|
will result as long as the ID is for a currently
|
|
processing job."
|
|
::= { settings-job 2 }
|
|
|
|
|
|
job-info-change-id OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(16))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the current value of an object in the job-info
|
|
sub-tree whose value has changed. Define the object
|
|
identifier for the object whose value has changed as
|
|
job-info.required-field.optional-field.job-id. job-info
|
|
represents the OID prefix of all objects in the job-info
|
|
sub-tree. Required-field represents the OID field value
|
|
that follows the job-info prefix. Since some objects in
|
|
the job-info sub-tree have two OID fields between the
|
|
job-info prefix and the job-id, the optional-field
|
|
represents the OID field between the required-field and
|
|
the job-id field, if present. Using this definition,
|
|
the format for the JOB-INFO-CHANGE-ID binary value can
|
|
be described as follows:
|
|
Bytes 0-3 : required-field
|
|
Bytes 4-7 : optional-field, or all zeros if there
|
|
is no optional field
|
|
Bytes 8-11: Job ID.
|
|
Bytes 12-n : The value of the object job-info.
|
|
required-field.optional-field.job-id.
|
|
All multi-byte values stored in Motorola (big-endian)
|
|
format, where the most significant byte occurs first.
|
|
Additional information:
|
|
LaserJet 5 will use this object to report changes of the
|
|
job-info-pages-printed and job-info-state objects.
|
|
Therefore, the optional-field will always be zeroes
|
|
and, because both of these are integers, the value
|
|
portion of the data will always be four bytes."
|
|
::= { settings-job 3 }
|
|
|
|
|
|
current-job-parsing-id OBJECT-TYPE
|
|
SYNTAX INTEGER(-1..32767)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Contains the printer assigned job identification for the
|
|
job currently being processed by the processing PDL sub-
|
|
system. The job ID is a monotonically increasing
|
|
number. The job ID may be reset to zero at power-up and
|
|
may roll over to zero after reaching some maximum
|
|
value.
|
|
Additional information:
|
|
A value of -1 is returned when the printer is
|
|
not parsing a job.
|
|
When data for a new job is detected, this object is updated (the job may or
|
|
may not turn out to be a Null Job); however, the trap does not occur until the
|
|
printer determines that it is not a Null Job (a trapped value will differ from
|
|
the previous value by one or more).
|
|
Some JOB-INFO- objects are created when the first data bytes are received. If
|
|
the printer determines that the job is a Null Job, the JOB-INFO- objects
|
|
related to the Null Job are deleted. LaserJet 5 retains the JOB-INFO- objects for
|
|
the 12 most recent jobs that are not Null Jobs.
|
|
LaserJet 5 resets the job ID to zero at power-up and will increment it to 32767
|
|
before rolling it to zero. To distinguish whether a power cycle or a rollover
|
|
caused an id of zero, the object prtGeneralConfigChanges can be watched and if
|
|
it increments at the same time as CURRENT-JOB-PARSING-ID goes to zero, then a
|
|
power cycle is the most likely cause."
|
|
::= { job-being-parsed 1 }
|
|
|
|
|
|
job-info-name1 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Contains the first part of this print job's name. The
|
|
last OID field for this dynamic object contains the job
|
|
ID.
|
|
Additional information:
|
|
The job name is the string specified by the
|
|
NAME= parameter of the @PJL JOB command which
|
|
allows a maximum of 80 characters. The first 40 characters are in this object
|
|
and the second 40 are in JOB-INFO-NAME2. The symbol set is Roman-8.
|
|
When jobs are nested, the value assigned to this object is the name provided
|
|
by the most recent @PJL JOB NAME= command. If no name is is provided, a null
|
|
string is returned. Whenever a @PJL JOB NAME= command is received, the trap
|
|
occurs even if the name is the same."
|
|
::= { job-info 1 }
|
|
|
|
|
|
job-info-name2 OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Contains the second part of this print job's name. The
|
|
last OID field for this dynamic object contains the job
|
|
ID.
|
|
Additional information:
|
|
See JOB-INFO-NAME1-1."
|
|
::= { job-info 2 }
|
|
|
|
|
|
job-info-stage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates what printer sub-systems are currently
|
|
processing this print job. The last OID field for this
|
|
dynamic object contains the job ID.
|
|
cSourceSubsystem - some of the job is in the printer
|
|
I/O subsystem.
|
|
cProcessingSubsystem - some of the job is in the
|
|
printer imaging processing subsystem.
|
|
cDestinationSubsystem - some of the job is being
|
|
printed.
|
|
Additional information:
|
|
For LaserJet 5 cSourceSubsystem and cProcessingSubsystem
|
|
will always be set and cleared together.
|
|
A non-printing job will never set cDestinationSubsystem.
|
|
When a page is ready to be printed,
|
|
cDestinationSubsystem will be set even if
|
|
a page of a previous job is currently being printed. cDestinationSubsystem
|
|
remains set until the last page of the job has reached an output bin.
|
|
If a
|
|
page requires extensive processing and allows all the previous pages of a
|
|
job to complete printing cDestinationSubsystem will remain set
|
|
until the last page of the job is closed."
|
|
::= { job-info 10 }
|
|
|
|
|
|
job-info-io-source OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates which I/O source, the print job was received
|
|
over. The value maps to port numbering scheme supported
|
|
in the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
|
|
::= { job-info 11 }
|
|
|
|
|
|
job-info-pages-processed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates the number of pages processed by the
|
|
processing subsystem. If neither the cSourceSubsystem
|
|
or the cProcessingSubsystem items are in the associated
|
|
JOB-INFO-STAGE object, then this object contains the
|
|
total number of pages processed for this job. The last
|
|
OID field for this dynamic object contains the job ID.
|
|
Additional information:
|
|
This object is incremented by one when a page is
|
|
processed, regardless of the number of pages that are printed as a result of
|
|
the single page processed. In other words, it does not matter how many
|
|
identical copies of a page are printed, or no pages may be printed if
|
|
operating in silent run mode, this count is incremented only once.
|
|
A page is considered processed when all of the input data has been processed
|
|
for a page (the intermediate has been produced); the image of the page is not
|
|
necessarily completely formed."
|
|
::= { job-info 12 }
|
|
|
|
|
|
job-info-pages-printed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates the number of pages printed by the destination
|
|
subsystem. If non of the cSourceSubsystem,
|
|
cProcessingSubsystem or cDestinationSubsystem items are
|
|
in the associated JOB-INFO-STAGE object, then this
|
|
object contains the total number of pages printed for
|
|
this job. This value may increase by two each time for
|
|
duplex jobs. The last OID field for this dynamic object
|
|
contains the job ID.
|
|
Additional information:
|
|
If multiple copies of a page are printed, each copy
|
|
is counted individually."
|
|
::= { job-info 13 }
|
|
|
|
|
|
job-info-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates the number of bytes of data processed by the
|
|
processing subsystem. If neither of the
|
|
cSourceSubsystem or cProcessingSubsystem items are in
|
|
the associated JOB-INFO-STAGE object, then this object
|
|
contains the size of this job, in bytes. The last OID
|
|
field for this dynamic object contains the job ID.
|
|
Additional information:
|
|
This count may be incremented by values other than one
|
|
as blocks of data are processed; blocks of data (which may be as large as 2K
|
|
bytes) will be processed in a varying amount of time.
|
|
When a job completes, this count may not be the same as the
|
|
total number of bytes sent to the printer since some data before or after the
|
|
job may be considered to be outside the job. Also, for ill-formed PostScript
|
|
jobs (ones that do not use the ENTER LANGUAGE command) will be reported as
|
|
having approximately 256 extra bytes due to the way the language switching
|
|
is accomplished."
|
|
::= { job-info 14 }
|
|
|
|
|
|
job-info-state OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eAborted(3),
|
|
eWaitingForResources(4),
|
|
ePrinted(5),
|
|
eTerminating(7),
|
|
eCancelled(10),
|
|
eProcessing(11)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates the state of the job. The last OID field for
|
|
this dynamic object contains the job ID.
|
|
eAborted - the print job was aborted.
|
|
eWaitingForResources - the print job requires
|
|
resources that are not currently available.
|
|
ePrinted - the job has printed. The related JOB-INFO-
|
|
OUTCOME object indicates if any problems were
|
|
encountered while the job was processed.
|
|
eRetained - the job can be reprinted.
|
|
eTerminating - the job was aborted or cancelled and is
|
|
currently is terminating.
|
|
eInterrupted - the job has been interrupted. The job
|
|
can be continued.
|
|
ePaused - the job has been paused. The job can be
|
|
continuted.
|
|
eCancelled - the job has been cancelled.
|
|
eProcessing - the job is currently being printed
|
|
normally."
|
|
::= { job-info 15 }
|
|
|
|
|
|
job-info-outcome OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOk(3),
|
|
eWarningsEncountered(4),
|
|
eErrorsEncountered(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates if any warning or error conditions were
|
|
encountered while processing the assoicated job. The
|
|
last OID field for this dynamic object contains the job
|
|
ID."
|
|
::= { job-info 19 }
|
|
|
|
|
|
job-info-outbins-used OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates which output bins this job has delivered
|
|
printed pages to. The last OID field for this dynamic
|
|
object contains the job ID.
|
|
Additional information:
|
|
LaserJet 5 has only 1 output bin.
|
|
cOutbin1 is the top/face-down bin."
|
|
::= { job-info 20 }
|
|
|
|
|
|
job-info-physical-outbins-used OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates which physical output bins this job has
|
|
delivered printed pages to. The last OID field for this
|
|
dynamic object contains the job ID.
|
|
Additional information:
|
|
LaserJet 5 only has one output bin so this will
|
|
always be set to cOutbin1.
|
|
cOutbin1--Face-up bin"
|
|
::= { job-info 22 }
|
|
|
|
|
|
job-info-attr-1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. Attribute objects are saved
|
|
sequentially, starting with 1, after the start of a job.
|
|
If more attributes are set than there are objects to
|
|
store them, the excess JOBATTR values are ignored. If
|
|
the corresponding SET JOBATTR= command has not been
|
|
received when a get is done for this object, a status of
|
|
<noSuchName> will be returned."
|
|
::= { job-info-attribute 1 }
|
|
|
|
|
|
job-info-attr-2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 2 }
|
|
|
|
|
|
job-info-attr-3 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 3 }
|
|
|
|
|
|
job-info-attr-4 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 4 }
|
|
|
|
|
|
job-info-attr-5 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 5 }
|
|
|
|
|
|
job-info-attr-6 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 6 }
|
|
|
|
|
|
job-info-attr-7 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 7 }
|
|
|
|
|
|
job-info-attr-8 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 8 }
|
|
|
|
|
|
job-info-attr-9 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 9 }
|
|
|
|
|
|
job-info-attr-10 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 10 }
|
|
|
|
|
|
job-info-attr-11 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 11 }
|
|
|
|
|
|
job-info-attr-12 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 12 }
|
|
|
|
|
|
job-info-attr-13 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 13 }
|
|
|
|
|
|
job-info-attr-14 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 14 }
|
|
|
|
|
|
job-info-attr-15 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 15 }
|
|
|
|
|
|
job-info-attr-16 OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(1..80))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the value that was set in PJL via the SET
|
|
JOBATTR= command. See JOB-INFO-ATTR-1 for details."
|
|
::= { job-info-attribute 16 }
|
|
|
|
|
|
io-timeout OBJECT-TYPE
|
|
SYNTAX INTEGER(5..300)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The amount of time, in seconds, to wait for more print
|
|
job data to be received before an I/O timeout occurs.
|
|
The I/O channel being timed is the I/O channel that
|
|
received the data associated with the current print job.
|
|
If an I/O timeout occurs, the PDL processing sub-system
|
|
assumes all the data associated with the current print
|
|
job has been received, and processes the end of job in
|
|
an PDL specific manner. The POS specifies the supported
|
|
values.
|
|
Additional information:
|
|
IF an I/O timeout occurs,the PDL processing
|
|
sub-system will consider it an end of job condition only
|
|
if there is data from another I/O subsystem waiting to be
|
|
processed.
|
|
The supported values are 5 to 300 seconds.
|
|
Setting to a value outside the supported range returns
|
|
<badValue> status."
|
|
::= { settings-io 1 }
|
|
|
|
|
|
io-switch OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eYes(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates if the device will switch between I/O channels
|
|
when a job boundary is encountered and print job data is
|
|
available on another I/O channel."
|
|
::= { settings-io 2 }
|
|
|
|
|
|
io-buffering OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2),
|
|
eAuto(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or controls the manner in which the device
|
|
performs I/O data buffering. I/O data buffering allows
|
|
additional print job data to be buffered by the I/O sub-
|
|
system in an effort to allow the computer sending the
|
|
data to perform other tasks and to keep the PDL
|
|
processing sub-system busy. eOff, I/O buffering is
|
|
disabled. When eOn, I/O buffering is enabled and the
|
|
IO-BUFFER-SIZE object controls the amount of memory set
|
|
aside for I/O buffer. When eAuto, I/O buffering is
|
|
enabled and the I/O buffer size is determined
|
|
automatically by the device and the IO-BUFFER-SIZE
|
|
object is not used.
|
|
Additional information:
|
|
In a PCL-only printer, all values may be set at any
|
|
time.
|
|
|
|
When PostScript is intalled and there is less than 6M of memory installed,
|
|
setting this object to eOn or eAuto will caue <badValue>
|
|
to be returned.
|
|
|
|
When PostScript and a duplexor are installed and there is less than 12M
|
|
of memory installed, setting this object to eOn or eAuto will cause
|
|
<badValue> to be returned.
|
|
|
|
When PostScript and 6M (12M with duplex unit) or more are installed, all
|
|
values are valid, provided Resource Saving has not consumed the needed
|
|
memory."
|
|
::= { settings-io 5 }
|
|
|
|
|
|
io-buffer-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or configures the amount of memory, in bytes,
|
|
dedicated to I/O print job data buffering. Attempting
|
|
to set to an unsupported value causes the device to use
|
|
the closest supported value. Each device POS should
|
|
document the list of supported values.
|
|
Additional information:
|
|
In LaserJet 5 the minimum supported value is 10,240.
|
|
The maximum supported value is dependent on total memory installed
|
|
and the amount of memory currently being used by other memory
|
|
consumers.
|
|
The buffer size must be a multiple of 1024, with the minimum value
|
|
being 10,240. Setting to an unsupported value causes the printer
|
|
to substitute the nearest value that is a multiple of 10,240
|
|
(if <100K) or 102,400 (if > 100K) and to return
|
|
<noError> status.
|
|
Examples of substituted values:
|
|
<= 15,360 will snap to 10,240
|
|
> 15,360 and <= 25,600 will snap to 20,480
|
|
> 25,600 and <= 35,840 will snap to 30,720
|
|
> 35,840 and <= 46,080 will snap to 40,960
|
|
> 46,080 and <= 56,320 will snap to 51,200
|
|
> 56,320 and <= 66,560 will snap to 61,440
|
|
> 66,560 and <= 76,800 will snap to 71,680
|
|
> 76,800 and <= 87,040 will snap to 81,920
|
|
> 87,040 and <= 97,280 will snap to 92,160
|
|
> 97,280 and <= 153,600 will snap to 102,400
|
|
> 153,600 and <= 256,000 will snap to 204,800
|
|
> 256,000 and <= 358,400 will snap to 307,200
|
|
> 358,400 and <= 460,800 will snap to 409,600
|
|
> 460,800 and <= 563,200 will snap to 512,000
|
|
> 563,200 and <= 665,600 will snap to 614,400
|
|
> 665,600 and <= 768,000 will snap to 716,800
|
|
> 768,000 and <= 870,400 will snap to 819,200
|
|
> 870,400 and <= 972,800 will snap to 921,600
|
|
> 972,800 and <= 1,075,200 will snap to 1,024,000
|
|
> 1,075,200 and <= 1,177,600 will snap to 1,126,400
|
|
> 1,177,600 and <= 1,280,000 will snap to 1,228,800
|
|
etc. up to the maximum supported amount of memory.
|
|
Attempting to set this object when IO-BUFFERING is eOff will cause a status
|
|
of <genErr> to be returned. When IO-BUFFERING is
|
|
eOff, reading this object will return a value of zero."
|
|
::= { settings-io 6 }
|
|
|
|
|
|
maximum-io-buffering-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the maximum amount of additional memory, in
|
|
bytes, that can be dedicated to buffering print job
|
|
data."
|
|
::= { settings-io 7 }
|
|
|
|
|
|
default-copies OBJECT-TYPE
|
|
SYNTAX INTEGER(1..999)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes default copies. Default copies is
|
|
the default values used by the PDL to control the number
|
|
of copies of each page in the print job that are
|
|
printed. The print job can override this value. The
|
|
list of supported values should be documented in the
|
|
device POS.
|
|
Additional information:
|
|
The supported values are 1 through 999.
|
|
Setting to an unsupported value causes the printer to substitute in a snap
|
|
value and to return <noError> status.
|
|
The snaps are as follows:
|
|
<1 snaps to 1
|
|
>999 snaps to 999"
|
|
::= { settings-pdl 4 }
|
|
|
|
|
|
form-feed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInitiateAction(1)
|
|
}
|
|
ACCESS write-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Instructs the PDL processing sub-system to finishing
|
|
processing the current page of the current job. Form
|
|
feed is also known as close page or eject page. If the
|
|
PDL processing sub-system is in a FORM-FEED-NEEDED
|
|
state, this causes the device to flush or finish
|
|
processing the current page of the current job. If the
|
|
device is not in the FORM-FEED-NEEDED state, an
|
|
<genErr> will occur."
|
|
::= { settings-pdl 5 }
|
|
|
|
|
|
resource-saving OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2),
|
|
eAuto(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes PDL resource saving. Resource saving
|
|
stores a PDL's permanent soft resources, like fonts,
|
|
even when another PDL is active. Resource saving is
|
|
also called environment saving. When eOff, resource
|
|
saving is disabled. When ON, resource saving is enabled
|
|
and memory is set aside for each PDL based on that PDL's
|
|
resource saving memory size object, to store that PDL's
|
|
permanent soft resources. When eAuto, resource saving
|
|
is enabled and memory space for each installed PDL is
|
|
determined automatically. The device POS should
|
|
document what values are legal when only one PDL is
|
|
installed.
|
|
Additional information:
|
|
When PCL is the only PDL
|
|
installed in LaserJet 5, eOn is not a legal value.
|
|
Attempting to set this object to
|
|
eOn with a PCL-only printer will result in a status of
|
|
<badValue> being returned.
|
|
|
|
When PostScript is installed and less than
|
|
7Meg of RAM is present, resource saving is not available. When at least 7Meg
|
|
of memory is installed with PostScript, then resource saving becomes available
|
|
and all three values are legal.
|
|
|
|
When PostScript and a duplexor are installed and there is less than 13M of
|
|
memory installed, the only vlaud value for this object is eOff. Attempting
|
|
to set this object to eOn or eAuto will cause
|
|
<badValue> to be returned.
|
|
|
|
When PostScript and 7M (13M with duplex unit) or more are installed, all
|
|
values are valid, provided I/O Buffering has not consumed the needed
|
|
memory.
|
|
|
|
This object is only supported if PostScript option is installed."
|
|
::= { settings-pdl 6 }
|
|
|
|
|
|
maximum-resource-saving-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the maximum amount of additional memory, in
|
|
bytes, that can be dedicated to holding PDL permanent
|
|
soft resources.
|
|
Additional information:
|
|
The following numbers assume that IO-BUFFERING=eOff;
|
|
if IO-BUFFERING<>eOff, the following numbers will be reduced by the value of
|
|
IO-BUFFER-SIZE.
|
|
|
|
Memory for resource saving is allocated in increments of 102400 bytes.
|
|
Therefore, for each 1M (1048576 bytes) of memory added to the printer, 102400
|
|
bytes are made available to resource saving (and I/O buffering) and 24576
|
|
bytes are retained until an additional 102400 byte block can be made
|
|
available. The value reported by this object is always rounded down to the
|
|
nearest multiple of 102400.
|
|
|
|
For a PCL-only printer, the value of this object is zero (all resource saving
|
|
memory is dedicated to PCL).
|
|
|
|
If PostScript is installed without a duplex unit, the value of this object is
|
|
as follows:
|
|
Zero if <7M memory is installed.
|
|
1048576 if 7M memory is installed and RESOURCE-SAVING=eOff.
|
|
1048576 if 7M memory is installed and RESOURCE-SAVING=eOn (note that this
|
|
value will be reduced by the amount of memory allocated to
|
|
PCL-RESOURCE-SAVING-MEMORY-SIZE and POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE).
|
|
819200 if 7M memory is installed and RESOURCE-SAVING=eAuto.
|
|
When RESOURCE-SAVING=eAuto, 819200 bytes of each 1M over 7M memory installed
|
|
are allocated to PCL and PostScript (409600 each) with the remaining bytes
|
|
added to this object.
|
|
When RESOURCE-SAVING=eOn or eOff, all bytes over 13M memory installed are
|
|
added to this object.
|
|
|
|
If PostScript is installed with a duplex unit, the value of this object is as
|
|
follows:
|
|
Zero if <13M memory is installed.
|
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eOff.
|
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eOn (note that this
|
|
value will be reduced by the amount of memory allocated to
|
|
PCL-RESOURCE-SAVING-MEMORY-SIZE and POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE).
|
|
1048576 if 13M memory is installed and RESOURCE-SAVING=eAuto.
|
|
When RESOURCE-SAVING=eAuto, 810200 bytes of each 1M over 13M memory installed
|
|
are allocated to PCL and PostScript (409600 each) with the remaining bytes
|
|
added to this object.
|
|
When RESOURCE-SAVING=eOn or eOff, all bytes over 13M memory installed are
|
|
added to this object.
|
|
|
|
The above listed values returned by this object will be reduced by the amount
|
|
of memory added to PCL-RESOURCE-SAVING-MEMORY-SIZE and
|
|
POSTSCRIPT-RESOURCE-SAVING-MEMORY-SIZE when RESOURCE-SAVING=eOn."
|
|
::= { settings-pdl 7 }
|
|
|
|
|
|
default-vertical-black-resolution OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the value of the default vertical
|
|
black resolution. The units are dots per inch.
|
|
Additional information:
|
|
In LaserJet 5 changing this OID also causes
|
|
DEFAULT- HORIZONTAL-BLACK RESOLUTION to change.
|
|
DEFAULT- HORIZONTAL-BLACK-RESOLUTION and
|
|
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
|
same. The supported values are 300 and 600.
|
|
Setting to an unsupported value causes the printer
|
|
to substitute in a snap value and
|
|
to return <noError> status.
|
|
The snap values are as follow:
|
|
<450 snap to 300
|
|
>=450 snap to 600"
|
|
::= { settings-pdl 8 }
|
|
|
|
|
|
default-horizontal-black-resolution OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the value of the default horizontal
|
|
black resolution. The units are dots per inch.
|
|
Additional information:
|
|
In LaserJet 5 changing this OID also causes
|
|
DEFAULT- VERTICAL-BLACK RESOLUTION to change.
|
|
DEFAULT- HORIZONTAL-BLACK-RESOLUTION and
|
|
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
|
|
same. The supported values are 300 and 600.
|
|
Setting to an unsupported value causes the printer
|
|
to substitute in a snap value and to
|
|
return <noError> status.
|
|
The snap values are as follow:
|
|
<450 snap to 300
|
|
>=450 snap to 600"
|
|
::= { settings-pdl 9 }
|
|
|
|
|
|
default-page-protect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOn(2),
|
|
eAuto(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the default page protection behavior.
|
|
If eOff, the device does not reserve memory for holding
|
|
the entire raster form of a processed page. If eOn,
|
|
then memory is reserved. If eAuto, the device
|
|
determines the amount of memory to reserve.
|
|
Additional information:
|
|
Setting to eOn causes MET to be more conservative, but
|
|
it will not allocate memory to hold an entire
|
|
rasterized page."
|
|
::= { settings-pdl 10 }
|
|
|
|
|
|
default-lines-per-page OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the default number of lines per page.
|
|
The POS indicates the supported values. An unsupported
|
|
value causes the printer to use the closest supported
|
|
value, causing the printer to return the
|
|
<noError>.
|
|
Additional information:
|
|
The supported values in LaserJet 5 are 5 to 128.
|
|
Setting to an unsupported value causes the
|
|
the printer to substitute in a snap value and to return
|
|
<noError>
|
|
status.
|
|
The snap values are as follow:
|
|
<5 snaps to 5
|
|
>128 snaps to 128"
|
|
::= { settings-pdl 11 }
|
|
|
|
|
|
default-vmi OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the default vertical motion index.
|
|
The unit of measure for VMI is centipoints per line.
|
|
The POS indicates the supported values. An unsupported
|
|
value causes the printer to use the closest supported
|
|
value, causing the printer to return
|
|
<noError>."
|
|
::= { settings-pdl 12 }
|
|
|
|
|
|
default-media-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eISOandJISA4(26),
|
|
eISOandJISA5(25),
|
|
eMonarch(80),
|
|
eCommercial10(81),
|
|
eInternationalDL(90),
|
|
eInternationalC5(91),
|
|
eInternationalB5(100)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This indicates the default media size. A write of an
|
|
unsupported value cases an <badValue>.
|
|
Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document."
|
|
::= { settings-pdl 13 }
|
|
|
|
|
|
cold-reset-media-size OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSLetter(2),
|
|
eISOandJISA4(26)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or sets the media size that is used as the
|
|
DEFAULT-MEDIA-SIZE when a cold reset occurs."
|
|
::= { settings-pdl 19 }
|
|
|
|
|
|
form-feed-needed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eFalse(1),
|
|
eTrue(2)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates if the PDL processing sub-system has made
|
|
marks on the current page and the source subsystem has
|
|
been idle for a device specific amount of time.
|
|
Additional information:
|
|
LaserJet 5 will set this object to eTrue when it has made
|
|
marks on the current page, the IO-TIMEOUT has expired and no data is pending
|
|
on another I/O. Once it is set to eTrue, more data on the same I/O will cause
|
|
this object to be set to eFalse, until the above conditions are met again."
|
|
::= { status-pdl 2 }
|
|
|
|
|
|
pcl-resource-saving-memory-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the amount of resource saving memory
|
|
set aside to hold permanent soft PCL resources.
|
|
Additional information:
|
|
The value returned by this object is the amount of
|
|
Resource Saving memory currently dedicated to PCL, regardless of the value of
|
|
RESOURCE-SAVING.
|
|
|
|
For a PCL-only printer, the value of this object is zero. All memory is
|
|
dedicated to PCL, but it is not shown as such.
|
|
|
|
If PostScript is installed without a duplex unit, the default value of this
|
|
object is as follows:
|
|
Zero if <7M memory is installed.
|
|
Zero if 7M memory is installed and RESOURCE-SAVING=eOff.
|
|
409600 if 7 memory is installed and RESOURCE-SAVING=eOn.
|
|
409600 if 7M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for
|
|
each 1M over 7M memory installed.
|
|
|
|
If PostScript is installed with a duplex unit, the default value of this
|
|
object is as follows:
|
|
Zero if <13M memory is installed.
|
|
Zero if 13M memory is installed and RESOURCE-SAVING=eOff.
|
|
409600 if 13M memory is installed and RESOURCE-SAVING=eOn.
|
|
409600 if 13M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for
|
|
each 1M over 13M memory installed.
|
|
|
|
If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource
|
|
Saving memory currently dedicated to PCL. The values supported are zero (to
|
|
turn resource saving off for PCL) and 409600 through 409600 plus the value of
|
|
MAXIMUM-RESOURCE-SAVING-MEMORY, in increments of 102400.
|
|
If a value is received that is between 1 and 409599, it will be snapped to
|
|
409600 and a status of <noError> returned.
|
|
If an unsupported value greater than 409600 is received,
|
|
it will be snapped down to the nearest 102400 value
|
|
and a status of <noError> returned.
|
|
|
|
Attempting to set this object when RESOURCE-SAVING
|
|
is eAuto or eOff will cause a status of <genErr> to
|
|
be returned."
|
|
::= { pdl-pcl 2 }
|
|
|
|
|
|
pcl-default-font-height OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the default PCL height. Height is an
|
|
approximate measure of the body of the type in
|
|
centipoints. A centipoint is 1/7200 inch. Height
|
|
applies only to proportional fonts. Point size, in
|
|
points, can be converted to font height, in centipoints,
|
|
by multiplying the point size by 100. The POS indicates
|
|
the supported values. An unsupported value causes the
|
|
printer to use the closest supported value, causing the
|
|
printer to return <noError>.''Closest'' means the smallest absolute difference.
|
|
Additional information:
|
|
Setting to an unsupported value causes the
|
|
printer to substitute in a snap value and to
|
|
return <noError> status.
|
|
The snap values are as follow:
|
|
<=400 snaps to 400
|
|
>=99975 snaps to 99975
|
|
Unsupported values in the range 400 to 99975 snaps
|
|
DOWN to the previous supported value
|
|
(i.e 25293 snaps to 25275 or 75038 snaps to 75025)."
|
|
::= { pdl-pcl 13 }
|
|
|
|
|
|
pcl-default-font-source OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInternal(1),
|
|
ePermanentSoft(2),
|
|
eRomSimm1(10),
|
|
eRomSimm2(11),
|
|
eRomSimm3(12),
|
|
eRomSimm4(13)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the value of the default font source
|
|
variable in NVRAM."
|
|
::= { pdl-pcl 14 }
|
|
|
|
|
|
pcl-default-font-number OBJECT-TYPE
|
|
SYNTAX INTEGER(0..255)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the value of the default font number
|
|
variable in NVRAM. Writing an unsupported value causes
|
|
the printer to generate an
|
|
<badValue>.
|
|
Additional information:
|
|
Valid numbers or 0 - 255, but only font numbers that are
|
|
included in the PCL FONT LIST are selectable."
|
|
::= { pdl-pcl 15 }
|
|
|
|
|
|
pcl-default-font-width OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the default PCL font width. Width is
|
|
expressed as the width of a character in centipoints. A
|
|
centipoint is 1/7200 inch. Width applies only to fixed
|
|
space fonts. Pitch, in character per inch, can be
|
|
converted to font width, in centipoints, by dividing
|
|
7200 by the pitch. The POS indicates the supported
|
|
values. An unsupported value causes the printer to use
|
|
the closest supported value, causing the printer to
|
|
return <noError>. ''Closest''
|
|
means the smallest absolute difference.
|
|
Additional information:
|
|
Setting to an unsupported value causes the
|
|
printer to substitue in a snap value (listed below)
|
|
and return <noError> status.
|
|
The snap values for pitch are as follow:
|
|
<=44 snaps to 44
|
|
>=9999 snaps to 9999"
|
|
::= { pdl-pcl 16 }
|
|
|
|
|
|
postscript-resource-saving-memory-size OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the amount of resource saving memory
|
|
set aside to hold permanent soft PostScript resources.
|
|
Additional information:
|
|
The value returned by this object is the amount of
|
|
Resource Saving memory currently dedicated to PostScript, regardless of the
|
|
value of RESOURCE-SAVING.
|
|
|
|
If PostScript is installed without a duplex unit, the default value of this
|
|
object is as follows:
|
|
Zero if <7M memory is installed.
|
|
Zero if 7M memory is installed and RESOURCE-SAVING=eOff.
|
|
409600 if 7M memory is installed and RESOURCE-SAVING=eOn.
|
|
409600 if 7M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for
|
|
each 1M over 7M memory installed.
|
|
|
|
If PostScript is installed with a duplex unit, the default value of this
|
|
object is as follows:
|
|
Zero if <13M memory is installed.
|
|
Zero if 13M memory is installed and RESOURCE-SAVING=eOff.
|
|
409600 if 13M memory is installed and RESOURCE-SAVING=eOn.
|
|
409600 if 13M memory is installed and RESOURCE-SAVING=eAuto; plus 102400 for
|
|
each 1M over 13M memory installed.
|
|
|
|
If RESOURCE-SAVING=eOn, this object can be used to set the amount of Resource
|
|
Saving memory currently dedicated to PostScript. The values supported are zero
|
|
(to turn resource saving off for PCL) and 409600 through 409600 plus
|
|
MAXIMUM-RESOURCE-SAVING-MEMORY, in increments of 102400. If a value is received
|
|
that is between 1 and 409599, it will be snapped to
|
|
409600 and a status of <noError> returned.
|
|
If an unsupported value greater than 409600 is received,
|
|
it will be snapped down to the nearest 102400 value
|
|
and a status of <noError> returned.
|
|
|
|
|
|
Attempting to set this object when RESOURCE-SAVING
|
|
is eAuto or eOff will cause a status of <genErr> to
|
|
be returned."
|
|
::= { pdl-postscript 2 }
|
|
|
|
|
|
postscript-print-errors OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the value of the print PostScript
|
|
errors setting. If eOn, PostScript prints an error page
|
|
showing the error encountered and the stack at the time
|
|
of the error.
|
|
Additional information:
|
|
This object is only supported if PostScript
|
|
option is installed."
|
|
::= { pdl-postscript 11 }
|
|
|
|
|
|
postscript-jam-recovery OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eOn(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the PostScript jam recovery setting.
|
|
If eOn, then the device will reprint PostScript pages,
|
|
if those pages jam.
|
|
Additional information:
|
|
This object is only supported if PostScript
|
|
option is installed."
|
|
::= { pdl-postscript 12 }
|
|
|
|
|
|
pjl-password OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns PJL password, if the password is not set (zero).
|
|
If the password is set, then attempting to retrieve the
|
|
password causes an <genErr> to occur
|
|
and will return the <NullValue>."
|
|
::= { pjl 1 }
|
|
|
|
|
|
print-density OBJECT-TYPE
|
|
SYNTAX INTEGER(1..5)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or sets the print density setting. Print
|
|
density is the instantaneous amount of marking agent
|
|
applied to the paper while printing. A value of zero
|
|
has the lowest print density, yielding a lighter page.
|
|
A value of 10 has the highest print density, yielding a
|
|
darker page. Each POS should document what values in
|
|
the 0 to 10 range are supported.
|
|
Additional information:
|
|
When this value is written, the page pipeline
|
|
will be flushed (all pages being printed are completed, no
|
|
new ones are started), the new density setting is set and
|
|
printing resumes. The acutal change in print density may be
|
|
gradual over several pages.
|
|
The supported values are 1 through 5. Setting to an
|
|
unsupported value causes the printer to substitue in a
|
|
a snap value and to return <noError>
|
|
status. The snap values are as follows:
|
|
<1 snaps to 1
|
|
>5 snaps to 5."
|
|
::= { settings-prt-eng 5 }
|
|
|
|
|
|
mp-tray OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eCassette(2),
|
|
eFirst(3)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the value of the multi-purpose (MP)
|
|
tray configuration variable. The MP tray can be
|
|
configured to operate as an additional input tray
|
|
(eCassette), a manual feed slot (eManual), or in a
|
|
manner compatible with the LaserJet III manual feed slot
|
|
(eFirst). If configured for eFirst, if media is present
|
|
in the MP tray, that media is used (assuming the size
|
|
matches and the print job didn't specify another tray)
|
|
until the MP tray is empty.
|
|
Additional information:
|
|
The MP tray can be configured for use either as a paper
|
|
cassette or as a priority manual feed tray. When the tray is configured as a manual feed tray, unsolicited status messages are not generated when there is no
|
|
paper in the tray. LaserJet 5 will pull media from TRAY 1 only if there is
|
|
a sheet present and it matches the needed size and type."
|
|
::= { settings-intray 5 }
|
|
|
|
|
|
tray1-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eISOandJISA5(25),
|
|
eISOandJISA4(26),
|
|
eMonarch(80),
|
|
eCommercial10(81),
|
|
eInternationalDL(90),
|
|
eInternationalC5(91),
|
|
eInternationalB5(100),
|
|
eCustom(101)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the media size that is currently
|
|
configuredconfigured in tray #1. This object can be set
|
|
to indicate the media size currently loaded, if the
|
|
printer supports input trays that can not sense the
|
|
media size. Complete list of supported media sizes
|
|
along with their dimensions are listed in the ''Media
|
|
Size Table'' near the end of this document."
|
|
::= { intray1 1 }
|
|
|
|
|
|
tray2-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eISOandJISA4(26)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the media size that is currently configured in
|
|
tray #2. Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document.
|
|
Additional information:
|
|
If the tray drawer is open, a get on this object
|
|
will cause a status of
|
|
<genErr> to be
|
|
returned. If the tray is empty, the size that the
|
|
tray is configured for will be returned."
|
|
::= { intray2 1 }
|
|
|
|
|
|
tray3-media-size-loaded OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eUSExecutive(1),
|
|
eUSLetter(2),
|
|
eUSLegal(3),
|
|
eISOandJISA4(26)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns the media size that is currently configured in
|
|
tray #3. Complete list of supported media sizes along
|
|
with their dimensions are listed in the ''Media Size
|
|
Table'' near the end of this document.
|
|
Additional information:
|
|
If the tray drawer is open, a get on this object
|
|
will cause a status of
|
|
<genErr> to be
|
|
returned. If the tray is empty, the size that the
|
|
tray is configured for will be returned"
|
|
::= { intray3 1 }
|
|
|
|
|
|
tray4-phd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Provides the number of the Paper Handling Device that
|
|
contains this input tray."
|
|
::= { intray4 12 }
|
|
|
|
|
|
low-marking-agent-processing OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eStop(1),
|
|
eCont(2)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes how the device processes a low
|
|
marking agent event. If eCont, then the device
|
|
continues to print. If eStop, then the device stops
|
|
until a continue event occurs."
|
|
::= { settings-marking-agent 3 }
|
|
|
|
|
|
default-ret OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eOff(1),
|
|
eLight(2),
|
|
eMedium(3),
|
|
eDark(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or changes the Resolution Enhancement Technology
|
|
setting. Devices that only support eOff and on should
|
|
map all other values to on and always return the same
|
|
non-eOff value to indicate on. The list of supported
|
|
values should be documented in the device POS.
|
|
Additional information:
|
|
This item may also be set via the Control panel or PJL.
|
|
Setting this object may cause a status of <noError> to be returned,
|
|
but the new value will not take effect until a job boundary is
|
|
reached. If a get is done on object before the job boundary is
|
|
reached, the value last set will be returned."
|
|
::= { imaging 5 }
|
|
|
|
|
|
default-print-quality OBJECT-TYPE
|
|
SYNTAX INTEGER(0..100)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Returns or sets the default print quality. A value of
|
|
zero has the lowest print quality. A value of 100 has
|
|
the highest print quality. Each POS should document
|
|
what values in the 0 to 100 range are supported.
|
|
Additional information:
|
|
In LaserJet 5, the supported values are 0 and
|
|
100. A value of zero has the lowest print
|
|
quality(ECONOMODE=ON), thus minimizes the amount of
|
|
toner used to print a page. A value of 100 has the
|
|
highest print quality (ECONOMODE=OFF), thus uses more
|
|
toner to print a page. Setting to an unsupported value
|
|
outside of the 0 to 100 range causes the printer to
|
|
return <badValue> status.
|
|
Setting to an unsupported value inside of the 0 to
|
|
100 range causes the printer to substitute in a snap
|
|
value (listed below) and to return
|
|
<noError> status.
|
|
The snap values are as follow:
|
|
0 to 50 snap to 0
|
|
51 to 100 snap to 100"
|
|
::= { imaging 7 }
|
|
|
|
|
|
channel-bytes-sent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The low order 31 bits of the number of bytes sent from
|
|
the printer to the host on this logical channel."
|
|
::= { channel-entry 2 }
|
|
|
|
|
|
channel-bytes-received OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The low order 31 bits of the number of bytes received by
|
|
the printer from the host on this logical channel."
|
|
::= { channel-entry 3 }
|
|
|
|
|
|
channel-io-errors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The low order 31 bits of the number of I/O errors which
|
|
have occured on this logical channel."
|
|
::= { channel-entry 4 }
|
|
|
|
|
|
channel-jobs-received OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The low order 31 bits of the number of print jobs which
|
|
have been received on this logical channel."
|
|
::= { channel-entry 5 }
|
|
|
|
|
|
file-system-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The amount of memory, in bytes, used by the file system
|
|
to buffer file data.
|
|
Additional information:
|
|
Reports the amount of memory, in bytes,
|
|
reserved for use by the file system. Returns
|
|
<noSuchName> status if attempting
|
|
to access this object and there is no storage device
|
|
is installed."
|
|
::= { settings-file-system 1 }
|
|
|
|
|
|
file-system-max-open-files OBJECT-TYPE
|
|
SYNTAX INTEGER(32..512)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of open files allowed at one time. Opening a
|
|
file when the maximum number of files are currently open
|
|
will fail.
|
|
Additional information:
|
|
Indicates the number of open files a
|
|
personality (e.g. PCL or PostScript) is guaranteed to be
|
|
able to open before the file system runs out of file handles.
|
|
After writing this object, the printer
|
|
must be rebooted before the change takes effect.
|
|
When setting this object to a specific value, the only
|
|
supported values are 32, 128, and 512. If a
|
|
value other then one of these is used, then the printer
|
|
will automatically determine the best number and snap
|
|
to either 32, 128 or 512.
|
|
Performing a cold reset sets this object
|
|
back to the factory default value. Returns
|
|
<noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { settings-file-system 2 }
|
|
|
|
|
|
file-system-statistic-read-open OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of times the file system has received
|
|
requests to open a file for reading. Opening a file for
|
|
both reading and writing will cause this value to
|
|
change. The POS should state if a power cycle causes
|
|
the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 1 }
|
|
|
|
|
|
file-system-statistic-write-open OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of times the file system has received
|
|
requests to open a file for writing. Opening a file for
|
|
both reading and writing will cause this value to
|
|
change. The POS should state if a power cycle causes
|
|
the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 2 }
|
|
|
|
|
|
file-system-statistic-successful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of file system requests
|
|
that completed successfully. The POS should state if a
|
|
power cycle causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 3 }
|
|
|
|
|
|
file-system-statistic-unsuccessful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of file system requests
|
|
that completed unsuccessfully. The POS should state if
|
|
a power cycle causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 4 }
|
|
|
|
|
|
file-system-statistic-current-memory-usage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A value indicating the number of bytes of RAM currently
|
|
used by the file system firmware.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 5 }
|
|
|
|
|
|
file-system-statistic-max-memory-usage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A value indicating the maximum number of bytes of RAM
|
|
used by the file system firmware. The POS should state
|
|
if the value is reset to zero after a power cycle.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-file-system 6 }
|
|
|
|
|
|
file-system2-initialize-volume OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eInitializing(2)
|
|
}
|
|
ACCESS write-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Setting this object to eInitializing causes file system
|
|
2 to be initialized. Reading this object indicates if
|
|
the file system is currently being initialized.
|
|
Additional information:
|
|
The hrDeviceIndex value for the mass storage
|
|
device is the same value that is used to index into the
|
|
FILE-SYSTEM sub-tree. Since this product only supports
|
|
one mass storage device, and since the hrDeviceIndex
|
|
for the mass storage device will be 2 if the mass storage device is
|
|
installed, the FILE-SYSTEM2-INITIALIZE-VOLUME object
|
|
will be the object that allows the mass storage device to be
|
|
initialized."
|
|
::= { file-system2 6 }
|
|
|
|
|
|
mass-storage-resource-change-counter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter which changes when a mass storage based
|
|
resource has been added or deleted.
|
|
Additional information:
|
|
The value of this counter changes
|
|
each time the MASS-STORAGE-RESOURCE-CHANGED object
|
|
is set to eTrue. The value also changes when the
|
|
mass storage device is initialized. However, the value does not
|
|
change when a mass storage device is removed and a different
|
|
mass storage device is installed. Initializing all volumes sets
|
|
this object back to the factory default value.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { mass-storage-resources 1 }
|
|
|
|
|
|
mass-storage-resource-changed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eTrue(2)
|
|
}
|
|
ACCESS write-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Setting to eTrue causes MASS-STORAGE-RESOURCE-CHANGE-
|
|
COUNTER to be incremented.
|
|
Additional information:
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { mass-storage-resources 2 }
|
|
|
|
|
|
rpc-test-return-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS write-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This test object that will not be supported in any
|
|
released product. Setting this object allows the next
|
|
RPC call return code to be specified. The POS will
|
|
specify the binary format.
|
|
Additional information:
|
|
The format of the binary data is a one
|
|
of three formats. The first format is no binary
|
|
data, which indicates the next RPC reply should not
|
|
be modified. The other two formats are described in
|
|
RFC 1057 and encoded using XDR (i.e. the value is
|
|
the data used to instead of the actual RPC reply).
|
|
The second format is when reply_stat is MSG_ACCEPTED
|
|
and accept_stat is something other than SUCCESS.
|
|
The third format is when reply_stat is MSG_DENIED.
|
|
Notice that all RPC replies that do not contain any
|
|
'results' are supported."
|
|
::= { settings-rpc 1 }
|
|
|
|
|
|
rpc-bind-protocol-address OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Array of Berkeley sockets style protocol addresses used
|
|
to bind RPC to a communications protocol family.
|
|
Setting an instance of this array object to a zero
|
|
length binary value disables the transport protocol
|
|
indicated by that instance. All multi-bytes fields are
|
|
in network (or big-endian) order. Bytes 1 and 2
|
|
indicate the transport protocol. Some of the transport
|
|
protocol mapping information can be found in RFC 1010
|
|
Assigned Numbers. A list of interesting transport
|
|
protocol number mappings include:
|
|
Protocol | Number
|
|
---------+-------
|
|
UDP/IP | 17
|
|
IPX | 1000
|
|
Bytes 3 and 4 indicate the address family. The address
|
|
family uses the same mapping as the BSD sockets address
|
|
family. A list of interesting address family mappings
|
|
include:
|
|
Address Family | Number
|
|
---------------+-------
|
|
Internet | 2
|
|
NetWare | 6
|
|
The format the fifth and following bytes is dependent on
|
|
the address family. For the Internet address family,
|
|
bytes 5 and 6 contain the port number, bytes 7 through
|
|
10 contain the IP address, and the following eight bytes
|
|
are unused. For NetWare, bytes 5 through 8 are the
|
|
network number, bytes 9 through 14 are the node number,
|
|
and bytes 15 and 16 are the socket number.
|
|
Additional information:
|
|
The length of the binary value is zero
|
|
if the instance of an object in the rpc-bind-protocol-address
|
|
array is not in use. A side effect of the
|
|
implementation is initializing the mass storage device sets this object
|
|
back to the factory default value.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { settings-rpc 2 }
|
|
|
|
|
|
rpc-statistic-successful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of RPC requests that
|
|
completed successfully (reply_data stat is SUCCESS).
|
|
The POS should state if a power cycle causes the counter
|
|
is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc 1 }
|
|
|
|
|
|
rpc-statistic-unsuccessful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of RPC requests that
|
|
completed unsuccessfully (reply_data stat is not
|
|
SUCCESS). The POS should state if a power cycle causes
|
|
the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc 2 }
|
|
|
|
|
|
rpc-bound-protocol-address OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"An array of Berkeley sockets style protocol addresses
|
|
that the NFS service has been bound to successful. The
|
|
format is that same as the array of RPC-BIND-PROTOCOL-
|
|
ADDRESS of objects.
|
|
Additional information:
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc 3 }
|
|
|
|
|
|
nfs-server-memory OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The amount of memory, in bytes, used by the Network File
|
|
System server to buffer file data.
|
|
Additional information:
|
|
Reports the amount of memory, in bytes,
|
|
reserved for use by the NFS server. A
|
|
side effect of the implementation is initializing
|
|
the mass storage device sets this object back to the factory
|
|
default value. Also includes the memory used by
|
|
other firmware components in addition to the NFS
|
|
server. Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { settings-nfs-server 1 }
|
|
|
|
|
|
nfs-server-read-size OBJECT-TYPE
|
|
SYNTAX INTEGER(256..1500)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum amount of data transferred in one NFS server
|
|
read data call.
|
|
Additional information:
|
|
A side effect of the
|
|
implementation is initializing the mass storage device sets this object
|
|
back to the factory default value.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { settings-nfs-server 2 }
|
|
|
|
|
|
nfs-server-write-size OBJECT-TYPE
|
|
SYNTAX INTEGER(256..1500)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum amount of data transferred in one NFS server
|
|
write data call.
|
|
Additional information:
|
|
A side effect of the
|
|
implementation is initializing the mass storage device sets this object
|
|
back to the factory default value.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { settings-nfs-server 3 }
|
|
|
|
|
|
nfs-server-statistic-successful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of NFS requests that
|
|
completed without error. The POS should state if a
|
|
power cycle causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-nfs-server 1 }
|
|
|
|
|
|
nfs-server-statistic-unsuccessful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of NFS requests that
|
|
completed with an NFS status other than NFS_OK (0). The
|
|
POS should state if a power cycle causes the counter is
|
|
be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-nfs-server 2 }
|
|
|
|
|
|
nfs-server-statistic-current-memory-usage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A value indicating the number of bytes of RAM currently
|
|
used by the NFS firmware.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-nfs-server 4 }
|
|
|
|
|
|
nfs-server-statistic-max-memory-usage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A value indicating the maximum number of bytes of RAM
|
|
used by the NFS firmware. The POS should state if the
|
|
value is reset to zero after a power cycle.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-nfs-server 5 }
|
|
|
|
|
|
rpc-bind-test-return-code OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS write-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This test object that will not be supported in any
|
|
released product. Setting this object allows the next
|
|
RPC bind call return code to be specified. The POS will
|
|
specify the binary format.
|
|
Additional information:
|
|
A one byte value.
|
|
value | meaning
|
|
------+------------------
|
|
1 | Next GetPort or GetAddr will receive port 0
|
|
| (indicating the service is not supported).
|
|
2 | Next Dump will receive an empty table."
|
|
::= { settings-rpc-bind 1 }
|
|
|
|
|
|
rpc-bind-statistic-successful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of RPC bind (RPC program
|
|
number 100000, version 2) requests that completed
|
|
successfully. The POS should state if a power cycle
|
|
causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc-bind 1 }
|
|
|
|
|
|
rpc-bind-statistic-unsuccessful OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of RPC bind (RPC program
|
|
number 100000, version 2) requests that completed
|
|
unsuccessfully. The POS should state if a power cycle
|
|
causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-rpc-bind 2 }
|
|
|
|
|
|
xip-statistic-processed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of XIP requests that
|
|
were processed. The POS should state if a power cycle
|
|
causes the counter is be reset to zero.
|
|
Additional information:
|
|
The number of XIP datagrams that have
|
|
been received by the XIP service. Reset to the
|
|
factory default value after a power cycle. Returns
|
|
<noSuchName> status if attempting
|
|
to access this object and there is no storage device
|
|
is installed."
|
|
::= { status-xip 1 }
|
|
|
|
|
|
xip-statistic-data-in-dropped OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A counter indicating the number of XIP data in datagrams
|
|
that were dropped (typically due to the printer being
|
|
flooded with XIP requests ). The POS should state if a
|
|
power cycle causes the counter is be reset to zero.
|
|
Additional information:
|
|
Reset to the factory default value after
|
|
a power cycle.
|
|
Returns <noSuchName>
|
|
status if attempting to access this object and there
|
|
is no storage device is installed."
|
|
::= { status-xip 2 }
|
|
|
|
|
|
hrmemorysize OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of physical main memory contained by
|
|
the host.
|
|
Additional information:
|
|
The unit of measure for this object is 1024 bytes.
|
|
The default value assumes the base printer with no
|
|
additional memory."
|
|
::= { hrStorage 2 }
|
|
|
|
|
|
hrstorageindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each logical storage area
|
|
contained by the host."
|
|
::= { hrStorageEntry 1 }
|
|
|
|
|
|
hrstoragetype OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The type of storage represented by this entry."
|
|
::= { hrStorageEntry 2 }
|
|
|
|
|
|
hrstoragedescr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A description of the type and instance of the
|
|
storage described by this entry.
|
|
Additional information:
|
|
This object is not localized."
|
|
::= { hrStorageEntry 3 }
|
|
|
|
|
|
hrstorageallocationunits OBJECT-TYPE
|
|
SYNTAX INTEGER(1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size, in bytes, of the data objects allocated
|
|
from this pool. If this entry is monitoring
|
|
sectors, blocks, buffers, or packets, for example,
|
|
this number will commonly be greater than one.
|
|
Otherwise this number will typically be one.
|
|
Additional information:
|
|
Unit is one byte."
|
|
::= { hrStorageEntry 4 }
|
|
|
|
|
|
hrstoragesize OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The size of the storage represented by this entry,
|
|
in units of hrStorageAllocationUnits.
|
|
Additional information:
|
|
Total formatter RAM."
|
|
::= { hrStorageEntry 5 }
|
|
|
|
|
|
hrstorageused OBJECT-TYPE
|
|
SYNTAX INTEGER(0..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The amount of the storage represented by this
|
|
entry that is allocated, in units of
|
|
hrStorageAllocationUnits.
|
|
Additional information:
|
|
This object should not be used when creating a print
|
|
job for the device because the amount of memory in use will
|
|
likely be different when the printer processes the print job."
|
|
::= { hrStorageEntry 6 }
|
|
|
|
|
|
hrstorageallocationfailures OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of requests for storage represented by
|
|
this entry that could not be honored due to not
|
|
enough storage. It should be noted that as this
|
|
object has a SYNTAX of Counter, that it does not
|
|
have a defined initial value. However, it is
|
|
recommended that this object be initialized to
|
|
zero.
|
|
Additional information:
|
|
This object is set to zero at power on and when any
|
|
reset is done via prtGeneralReset.
|
|
This object is incremented whenever the printer is
|
|
short on memory. "
|
|
::= { hrStorageEntry 7 }
|
|
|
|
|
|
hrdeviceindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..2147483647)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A unique value for each device contained by the
|
|
host. The value for each device must remain
|
|
constant at least from one re-initialization of the
|
|
agent to the next re-initialization.
|
|
Additional information:
|
|
The entry in the Device Table which
|
|
describes the printer. "
|
|
::= { hrDeviceEntry 1 }
|
|
|
|
|
|
hrdevicetype OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"An indication of the type of device.
|
|
If this value is `hrDeviceProcessor { hrDeviceTypes
|
|
3 }' then an entry exists in the hrProcessorTable
|
|
which corresponds to this device.
|
|
If this value is `hrDeviceNetwork { hrDeviceTypes 4
|
|
}', then an entry exists in the hrNetworkTable
|
|
which corresponds to this device.
|
|
If this value is `hrDevicePrinter { hrDeviceTypes 5
|
|
}', then an entry exists in the hrPrinterTable
|
|
which corresponds to this device.
|
|
If this value is `hrDeviceDiskStorage {
|
|
hrDeviceTypes 6 }', then an entry exists in the
|
|
hrDiskStorageTable which corresponds to this
|
|
device."
|
|
::= { hrDeviceEntry 2 }
|
|
|
|
|
|
hrdevicedescr OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..64))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A textual description of this device, including
|
|
the device's manufacturer and revision, and
|
|
optionally, its serial number.
|
|
Additional information:
|
|
This object is not localized."
|
|
::= { hrDeviceEntry 3 }
|
|
|
|
|
|
hrdeviceid OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The product ID for this device.
|
|
Additional information:
|
|
The complete OID reported by this object is:
|
|
.1.3.6.1.4.1.11.2.3.9.1.2.2"
|
|
::= { hrDeviceEntry 4 }
|
|
|
|
|
|
hrdevicestatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHrunning(2),
|
|
eHwarning(3),
|
|
eHdown(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current operational state of the device
|
|
described by this row of the table. A value
|
|
unknown(1) indicates that the current state of the
|
|
device is unknown. running(2) indicates that the
|
|
device is up and running and that no unusual error
|
|
conditions are known. The warning(3) state
|
|
indicates that agent has been informed of an
|
|
unusual error condition by the operational software
|
|
(e.g., a disk device driver) but that the device is
|
|
still 'operational'. An example would be high
|
|
number of soft errors on a disk. A value of
|
|
testing(4), indicates that the device is not
|
|
available for use because it is in the testing
|
|
state. The state of down(5) is used only when the
|
|
agent has been informed that the device is not
|
|
available for any use.
|
|
Additional information:
|
|
The printer's condition is mapped as follows:
|
|
eHrunning -- Printer ready to print or is printing.
|
|
May be in power save mode.
|
|
eHwarning -- A condition exists that needs attention but it is
|
|
not currently preventing printing. A non-critical alert is
|
|
active.
|
|
eHtesting -- Printer is printing an internal page.
|
|
eHdown -- Printer is not printing due to an error condition. A
|
|
critical alert is active, human interaction is needed to bring the printer to
|
|
a ready state or the printer is offline."
|
|
::= { hrDeviceEntry 5 }
|
|
|
|
|
|
hrdeviceerrors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The number of errors detected on this device. It
|
|
should be noted that as this object has a SYNTAX
|
|
of Counter, that it does not have a defined
|
|
initial value. However, it is recommended that
|
|
this object be initialized to zero.
|
|
Additional information:
|
|
This is the number of critical alerts that have been
|
|
entered into the alert table since the device was powered on.
|
|
The maximum value for this object is 2^32-1."
|
|
::= { hrDeviceEntry 6 }
|
|
|
|
|
|
hrprinterstatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eHother(1),
|
|
eHidle(3),
|
|
eHprinting(4),
|
|
eHwarmup(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The current status of this printer device. When
|
|
in the idle(1), printing(2), or warmup(3) state,
|
|
the corresponding hrDeviceStatus should be
|
|
running(2) or warning(3). When in the unknown
|
|
state, the corresponding hrDeviceStatus should be
|
|
unknown(1).
|
|
Additional information:
|
|
The printer's condition is mapped as follows:
|
|
eHidle -- The printer is not doing any of the items listed below
|
|
for eHprinting status.
|
|
eHprinting -- The printer is processing PJL or PDL data, waiting
|
|
for an error condition to be cleared, processing a control
|
|
panel request, waiting for the engine to become ready or
|
|
printing images.
|
|
eHwarmup -- If hrDeviceStatus is eHdown, then the printer is
|
|
currently offline but is resolving
|
|
the condition that caused it be offline it will be online
|
|
when it is ready to print. If hrDeviceStatus is eHrunning,
|
|
then the printer was in power save mode and is now becoming
|
|
ready to print."
|
|
::= { hrPrinterEntry 1 }
|
|
|
|
|
|
hrprinterdetectederrorstate OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This object represents any error conditions
|
|
detected by the printer. The error conditions are
|
|
encoded as bits in an octet string, with the
|
|
following definitions:
|
|
Condition Bit # hrDeviceStatus
|
|
lowPaper 0 warning(3)
|
|
noPaper 1 down(5)
|
|
lowToner 2 warning(3)
|
|
noToner 3 down(5)
|
|
doorOpen 4 down(5)
|
|
jammed 5 down(5)
|
|
offline 6 down(5)
|
|
serviceRequested 7 warning(3)
|
|
If multiple conditions are currently detected and
|
|
the hrDeviceStatus would not otherwise be
|
|
unknown(1) or testing(4), the hrDeviceStatus shall
|
|
correspond to the worst state of those indicated,
|
|
where down(5) is worse than warning(3) which is
|
|
worse than running(2).
|
|
Bits are numbered starting with the most
|
|
significant bit of the first byte being bit 0, the
|
|
least significant bit of the first byte being bit
|
|
7, the most significant bit of the second byte
|
|
being bit 8, and so on. A one bit encodes that
|
|
the condition was detected, while a zero bit
|
|
encodes that the condition was not detected.
|
|
This object is useful for alerting an operator to
|
|
specific warning or error conditions that may
|
|
occur, especially those requiring human
|
|
intervention.
|
|
Additional information:
|
|
LaserJet 5 reports error conditions as follows:
|
|
lowPaper -- A tray is empty, but the media to be loaded is not
|
|
currently needed.
|
|
hrDeviceStatus = eHwarning;
|
|
hrPrinterStatus = eHidle or eHprinting;
|
|
a non-critical alert is active.
|
|
noPaper -- A tray is empty and must be filled for printing to
|
|
continue.
|
|
hrDeviceStatus = eHdown;
|
|
hrPrinterStatus = eHother;
|
|
a non-critical alert is active.
|
|
lowToner -- A toner low condition has been detected.
|
|
hrDeviceStatus = eHwarning;
|
|
hrPrinterStatus = eHidle or eHprinting;
|
|
a non-critical alert is active.
|
|
noToner -- LaserJet 5 does not report this condition.
|
|
doorOpen -- A door is open.
|
|
hrDeviceStatus = eHdown;
|
|
hrPrinterStatus = eHother;
|
|
a non-critical alert is active.
|
|
jammed -- A jam condition is preventing printing.
|
|
hrDeviceStatus = eHdown;
|
|
hrPrinterStatus = eHother;
|
|
a non-critical alert is active.
|
|
offline -- Printer is offline.
|
|
hrDeviceStatus = eHdown;
|
|
hrPrinterStatus = eHother;
|
|
a non-critical alert is active.
|
|
serviceRequested -- Any status or error condition not listed
|
|
above. If the condition prevents printing, the 'offline'
|
|
bit is also set and its hrDeviceStatus and hrPrinterStatus
|
|
would prevail.
|
|
hrDeviceStatus = eHwarning;
|
|
hrPrinterStatus = eHidle or eHprinting;
|
|
a non-critical alert is active."
|
|
::= { hrPrinterEntry 2 }
|
|
|
|
|
|
prtgeneralconfigchanges OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Counts configuration changes that change the capabilities of
|
|
a printer, such as the addition/deletion of input/output bins,
|
|
the addition/deletion of interpreters, or changes in media
|
|
size. Such changes will often affect the capability of the
|
|
printer to service certain types of print jobs.
|
|
Management applications may cache infrequently changed
|
|
configuration information about sub-units on the printer.
|
|
This object should be incremented whenever the agent wishes
|
|
such applications to invalidate that cache and re-download
|
|
all of this configuration information, thereby signalling a
|
|
change in the printer's configuration.
|
|
For example, if an input tray that contained paper of
|
|
different dimensions was added, this counter would be
|
|
incremented.
|
|
As an additional example, this counter would not be
|
|
incremented when an input tray is removed or the level of an
|
|
input device changes.
|
|
Additional information:
|
|
This is a 32 bit counter (unsigned). When it reaches
|
|
its maximum value, it will roll to zero."
|
|
::= { prtGeneralEntry 1 }
|
|
|
|
|
|
prtgeneralcurrentlocalization OBJECT-TYPE
|
|
SYNTAX INTEGER(1..13)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of the prtLocalizationIndex corresponding to the
|
|
current language, country, and character set to be used for
|
|
localized string values that are identified as being dependent
|
|
on the value of this object. Note that this object does not
|
|
apply to localized strings in the prtConsole group or any
|
|
object that is not identified as above.
|
|
Additional information:
|
|
The value of this object is saved in NVRAM."
|
|
::= { prtGeneralEntry 2 }
|
|
|
|
|
|
prtgeneralreset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePnotResetting(3),
|
|
ePpowerCycleReset(4),
|
|
ePresetToNVRAM(5),
|
|
ePresetToFactoryDefaults(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Setting this value to `powerCycleReset', `resetToNVRAM', or
|
|
`resetToFactoryDefaults' will result in the resetting of the
|
|
printer. When read, this object will always have the value
|
|
`notResetting(3)', and a SET of the value `notResetting' shall
|
|
have no effect on the printer. Some of the defined values are
|
|
optional. However, every implementation must support at least
|
|
the values `notResetting' and resetToNVRAM'.
|
|
Additional information:
|
|
All resets follow the same sequence of events except that a
|
|
a value of ePresetToFactoryDefaults first makes a call to reset the NVRAM to
|
|
factory defaults. Then, the following sequence of events occur:
|
|
1. Wait until a job boundary.
|
|
2. The paper path is flushed.
|
|
3. The printer is reset per the request. The printer will respond to PML
|
|
requests up to this point in time.
|
|
|
|
All settings will make the printer go thru its Power on initialization
|
|
routines. And I/O cards are reset.
|
|
|
|
Setting this object to ePpowerCycleReset causes LaserJet 5 to perform its power
|
|
on initialization routines. I/O cards are reset (NVRAM on the cards is not
|
|
changed; all I/O buffers are flushed).
|
|
The tests normally run at power on time are executed.
|
|
|
|
Setting this object to ePresetToNVRAM causes the printer to reset itself to
|
|
its power on state without doing its normal power on testing. The I/O cards
|
|
are not reset and I/O buffers remain intact.
|
|
|
|
Setting this object to ePresetToFactoryDefaults causes the same action as a
|
|
Cold Reset operation performed at the control panel (except power on testing
|
|
is not performed). The I/O cards
|
|
are not reset and I/O buffers remain intact."
|
|
::= { prtGeneralEntry 3 }
|
|
|
|
|
|
prtcoverdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The manufacturer provided cover sub-mechanism name in the
|
|
localization specified by prtGeneralCurrentLocalization."
|
|
::= { prtCoverEntry 2 }
|
|
|
|
|
|
prtcoverstatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePdoorOpen(3),
|
|
ePdoorClosed(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The status of this cover sub-unit. "
|
|
::= { prtCoverEntry 3 }
|
|
|
|
|
|
prtlocalizationlanguage OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..2))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A two character language code from ISO 639. Examples EN, GB,
|
|
CA, FR, DE.
|
|
Additional information:
|
|
The languages supported by LaserJet 5 are English,
|
|
Danish, Dutch, Finnish, French, German, Italian, Norwegian, Polish, Portuguese,
|
|
Spanish, Swedish, Turkish."
|
|
::= { prtLocalizationEntry 2 }
|
|
|
|
|
|
prtlocalizationcountry OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..2))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A two character country code from ISO 3166, a blank string
|
|
(two space characters) shall indicate that the country is
|
|
not defined. Examples: US, FR, DE, ...
|
|
Additional information:
|
|
The languages supported by LaserJet 5 (and corresponding
|
|
country) are English (United States), Danish (Denmark), Dutch (Netherlands),
|
|
Finnish (Finland), French (France), German (Germany), Italian (Italy),
|
|
Norwegian (Norway), Polish (Poland), Portuguese (Portugal), Spanish (Spain),
|
|
Swedish (Sweden), Turkish (Turkey)"
|
|
::= { prtLocalizationEntry 3 }
|
|
|
|
|
|
prtlocalizationcharacterset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePcsHPRoman8(2004),
|
|
ePcsISOLatin2(5),
|
|
ePcsISOLatin5(12)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The coded character set used for this localization."
|
|
::= { prtLocalizationEntry 4 }
|
|
|
|
|
|
prtstoragerefindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of the hrDeviceIndex of the printer device that this
|
|
storageEntry is associated with."
|
|
::= { prtStorageRefEntry 2 }
|
|
|
|
|
|
prtdevicerefindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of the hrDeviceIndex of the printer device that this
|
|
deviceEntry is associated with."
|
|
::= { prtDeviceRefEntry 2 }
|
|
|
|
|
|
prtgeneralcurrentoperator OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The name of the current human operator responsible for
|
|
operating this printer. It is suggested that this string
|
|
include information that would enable other humans to reach
|
|
the operator, such as a phone number.
|
|
Additional information:
|
|
The maximum supported string length is 32 characters.
|
|
Length of 32 was chosen so a phone number could be
|
|
included with the name.
|
|
If the user entered string is too long, the device
|
|
will store as much as possible and will return the
|
|
<noError> status."
|
|
::= { prtGeneralEntry 4 }
|
|
|
|
|
|
prtgeneralserviceperson OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The name of the last human responsible for servicing
|
|
this printer. It is suggested that this string
|
|
include information that would enable other humans to reach
|
|
the service person, such as a phone number.
|
|
Additional information:
|
|
The maximum supported string length is 32 characters.
|
|
Length of 32 was chosen so a phone number could be
|
|
included with the name.
|
|
If the user entered string is too long, the device
|
|
will store as much as possible and will return the
|
|
<noError> status."
|
|
::= { prtGeneralEntry 5 }
|
|
|
|
|
|
prtinputdefaultindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of prtInputIndex corresponding to the default input
|
|
sub-unit: that is, this object selects the default source of
|
|
input media.
|
|
Additional information:
|
|
The default input tray is determined by the printer
|
|
based on DEFAULT-MEDIA-SIZE and whether or not Tray 3 is installed.
|
|
If Tray 1 is set in FIRST mode then the size of paper loaded in
|
|
Tray 1 is assumed to be the requested size and the printer will
|
|
pick from Tray 1 without regard to the requested size."
|
|
::= { prtGeneralEntry 6 }
|
|
|
|
|
|
prtinputtype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePunknown(2),
|
|
ePsheetFeedAutoRemovableTray(3),
|
|
ePsheetFeedAutoNonRemovableTray(4),
|
|
ePsheetFeedManual(5),
|
|
ePcontinuousRoll(6),
|
|
ePcontinuousFanFold(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The type of technology (discriminated primarily according to
|
|
feeder mechanism type) employed by the input sub-unit. Note,
|
|
the Optional Input Class provides for a descriptor field to
|
|
further qualify the other choice.
|
|
Additional information:
|
|
Tray 1 is the multi-purpose tray and is always present.
|
|
It supports both sheets and envelopes. Its type is
|
|
ePsheetFeedAutoNonRemovableTray.
|
|
Tray 2 is a removable tray that comes standard
|
|
with the printer, although it is usually not removed
|
|
from the printer. It is type
|
|
ePsheetFeedAutoRemovableTray.
|
|
Tray 3 is an optional Lower Cassette unit that can be
|
|
attached to the printer. It can only be sensed if
|
|
it is installed when the printer is powered ON. It is
|
|
type ePsheetFeedAutoRemovableTray.
|
|
The 4th tray in this array is the envelope feeder. It
|
|
can be detected even when it is installed while the
|
|
printer is powered on."
|
|
::= { prtInputEntry 2 }
|
|
|
|
|
|
prtinputdimunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The unit of measurement for use calculating and relaying
|
|
dimensional values for this input sub-unit."
|
|
::= { prtInputEntry 3 }
|
|
|
|
|
|
prtinputmediadimfeeddirdeclared OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This object provides the value of the declared dimension, in
|
|
the feed direction, of the media that is (or, if empty, was or
|
|
will be) in this input sub-unit. The feed direction is the
|
|
direction in which the media is fed on this sub-unit. This
|
|
dimension is measured in input sub-unit dimensional units
|
|
(prtInputDimUnit). If this input sub-unit can reliably sense
|
|
this value, the value is sensed by the printer and may not be
|
|
changed by management requests. Otherwise, the value may be
|
|
changed. The value (-1) means other and specifically means
|
|
that this sub-unit places no restriction on this parameter.
|
|
The value (-2) indicates unknown.
|
|
Additional information:
|
|
For trays 2 and 3 (which can reliably sense this
|
|
value) the objects behave exactly the same as prtInputMediaDimFeedDirChosen.
|
|
Attempting to set this object for trays 2 and 3 will cause
|
|
<noSuchName> to be returned.
|
|
The default values assume the trays are configured for letter size paper.
|
|
For tray 1 the value is the dimension for the media size currently declared.
|
|
For the envelope feeder (tray 4) the value is the dimension for the media
|
|
size currently declared.
|
|
Valid values are 63000 to 140000 if prtInputDimUnit is ePtenThousandthsOfInches
|
|
and 160000 to 356000 if prtInputDimUnit is ePmicrometers.
|
|
Valid values for the envelope feeder are 63000 to 10000. "
|
|
::= { prtInputEntry 4 }
|
|
|
|
|
|
prtinputmediadimxfeeddirdeclared OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This object provides the value of the declared dimension, in
|
|
the cross feed direction, of the media that is (or, if empty,
|
|
was or will be) in this input sub-unit. The cross feed
|
|
direction is ninety degrees relative to the feed direction
|
|
associated with this sub-unit. This dimension is measured in
|
|
input sub-unit dimensional units (prtInputDimUnit). If this
|
|
input sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed by management
|
|
requests. Otherwise, the value may be changed. The value (-1)
|
|
means other and specifically means that this sub-unit places
|
|
no restriction on this parameter. The value (-2) indicates
|
|
unknown.
|
|
Additional information:
|
|
For trays 2 and 3 (which can reliably sense this
|
|
value) the objects behave exactly the same as prtInputMediaDimXFeedDirChosen.
|
|
Attempting to set this object for trays 2 and 3 will cause
|
|
<noSuchName> to be returned.
|
|
The default values assume the trays are configured for letter size paper.
|
|
For tray 1 the value is the dimension for the media size currently declared.
|
|
Valid values are 35000 to 85000 if prtInputDimUnit is ePtenThousandthsOfInches
|
|
and 90000 to 216000 if prtInputDimUnit is ePmicrometers. Valid values for
|
|
the envelope feeder are 35000 to 70000"
|
|
::= { prtInputEntry 5 }
|
|
|
|
|
|
prtinputmediadimfeeddirchosen OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The printer will act as if media of the chosen dimension (in
|
|
the feed direction) is present in this input source. Note
|
|
that this value will be used even if the input tray is empty.
|
|
Feed dimension measurements
|
|
are taken parallel relative to the feed direction
|
|
associated with that sub-unit and are in input sub-unit
|
|
dimensional units (DimUnit). If the printer supports the
|
|
declared dimension, the granted dimension is the same as
|
|
the declared dimension. If not, the granted dimension is
|
|
set to the closest dimension that the printer supports
|
|
when the declared dimension is set. The value (-1) means
|
|
other and specifically indicates that this sub-unit
|
|
places no restriction on this parameter. The value (-2)
|
|
indicates unknown.
|
|
Additional information:
|
|
The objects for trays 2 and 3 reflect the
|
|
configuration of the corresponding trays. When the tray is removed, a value
|
|
of -2 is returned. The default values assume the trays are configured for
|
|
letter size paper. The object for tray 1 and the envelope feeder returns
|
|
the value of the media size for which the tray is currently configured
|
|
because they cannot sense what size media it contains."
|
|
::= { prtInputEntry 6 }
|
|
|
|
|
|
prtinputmediadimxfeeddirchosen OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The printer will act as if media of the chosen dimension (in
|
|
the cross feed direction) is present in this input source.
|
|
Note that this value will be used even if the input tray is
|
|
empty. The cross feed direction is ninety degrees relative
|
|
to the feed direction associated with this sub-unit. This
|
|
dimension is measured in input sub-unit dimensional units
|
|
(DimUnit). If the printer supports the declared
|
|
dimension, the granted dimension is the same as the
|
|
declared dimension. If not, the granted dimension is set
|
|
to the closest dimension that the printer supports when
|
|
the declared dimension is set. The value (-1) means other
|
|
and specifically indicates that this sub-unit places no
|
|
restriction on this parameter. The value (-2) indicates
|
|
unknown.
|
|
Additional information:
|
|
The objects for trays 2 and 3 reflect the
|
|
configuration of the corresponding trays. When the tray is removed, a value
|
|
of -2 is returned. The default values assume the trays are configured for
|
|
letter size paper. The object for tray 1 and the envelope feeder returns
|
|
the value of the media size for which the tray is currently configured
|
|
because they cannot sense what size media it contains."
|
|
::= { prtInputEntry 7 }
|
|
|
|
|
|
prtinputcapacityunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4),
|
|
ePsheets(8),
|
|
ePfeet(16),
|
|
ePmeters(17)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The unit of measurement for use in calculating and relaying
|
|
capacity values for this input sub-unit.
|
|
Additional information:
|
|
A sheet is a single piece of 20 pound paper. For tray
|
|
4, the envelope feeder, a sheet is one envelope"
|
|
::= { prtInputEntry 8 }
|
|
|
|
|
|
prtinputmaxcapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum capacity of the input sub-unit in input
|
|
sub-unit capacity units (CapacityUnit). There is no
|
|
convention associated with the media itself so this value
|
|
reflects claimed capacity. If this input sub-unit can
|
|
reliably sense this value, the value is sensed by the
|
|
printer and may not be changed by management requests;
|
|
otherwise, the value may be written (by a Remote
|
|
Contol Panel or a Management Application).
|
|
The value (-1) means other and specifically
|
|
indicates that the sub-unit places no restrictions
|
|
on this parameter. The value (-2) means unknown.
|
|
Additional information:
|
|
This is specified assuming 20 pound paper for the paper trays."
|
|
::= { prtInputEntry 9 }
|
|
|
|
|
|
prtinputcurrentlevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The current capacity of the input sub-unit in input
|
|
sub-unit capacity units (CapacityUnit). If this input
|
|
sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed by
|
|
management requests; otherwise, the value may
|
|
be written (by a Remote Contol Panel or a
|
|
Management Application). The value (-1) means other and
|
|
specifically indicates that the sub-unit places no
|
|
restrictions on this parameter. The value (-2) means unknown.
|
|
The value (-3) means that the printer knows that at least one
|
|
unit remains.
|
|
Additional information:
|
|
LaserJet 5 can only detect empty/not empty in it's
|
|
trays. It returns -3 for not empty and 0 for empty.
|
|
If a tray is removed, a value of -2 (unknown) will
|
|
be returned."
|
|
::= { prtInputEntry 10 }
|
|
|
|
|
|
prtinputstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The current status of this input sub-unit.
|
|
The status is an integer that is the sum of 5
|
|
distinct values, Availability, Non-Critical, Critical,
|
|
On-line, and Transitioning. These values are:
|
|
Availability value
|
|
Available and Idle 0 000'b
|
|
Available and Standby 2 010'b
|
|
Available and Active 4 100'b
|
|
Available and Busy 6 110'b
|
|
Unavailable and OnRequest 1 001'b
|
|
Unavailable because Broken 3 011'b
|
|
Unknown 5 101'b
|
|
Non-Critical
|
|
No Non-Critical Alerts 0
|
|
Non-Critical Alerts 8
|
|
Critical
|
|
No Critical Alerts 0
|
|
Critical Alerts 16
|
|
On-Line
|
|
Intended state is On-Line 0
|
|
Intended state is Off-Line 32
|
|
Transitioning
|
|
At intended state 0
|
|
Transitioning to intended state 64 "
|
|
::= { prtInputEntry 11 }
|
|
|
|
|
|
prtinputmedianame OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A description of the media contained in this input sub-unit;
|
|
This description is intended for display to a human operator.
|
|
This description is not processed by the printer. It is used
|
|
to provide information not expressible in terms of the other
|
|
media attributes (e.g. prtInputMediaDimFeedDirChosen,
|
|
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
|
|
prtInputMediaType). An example would be `legal tender bond
|
|
paper'.
|
|
Additional information:
|
|
LaserJet 5 does not support the concept of named media types. "
|
|
::= { prtInputEntry 12 }
|
|
|
|
|
|
prtinputname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The name assigned to this input sub-unit. "
|
|
::= { prtInputEntry 13 }
|
|
|
|
|
|
prtinputvendorname OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The vendor name of this input sub-unit."
|
|
::= { prtInputEntry 14 }
|
|
|
|
|
|
prtinputmodel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The model name of this input sub-unit.
|
|
Additional information:
|
|
LaserJet 5 does not specify a model name for the
|
|
Tray1 or Tray2. Tray 3 and Tray 4 objects do not exist unless
|
|
the lower cassette or envelope feeder are installed."
|
|
::= { prtInputEntry 15 }
|
|
|
|
|
|
prtinputversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The version of this input sub-unit.
|
|
Additional information:
|
|
LaserJet 5 does not specify a version number
|
|
for the input trays."
|
|
::= { prtInputEntry 16 }
|
|
|
|
|
|
prtinputserialnumber OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..32))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The serial number assigned to this input sub-unit.
|
|
Additional information:
|
|
LaserJet 5 does not specify a serial number for the
|
|
input trays."
|
|
::= { prtInputEntry 17 }
|
|
|
|
|
|
prtinputdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A free-form text description of this input
|
|
sub-unit in the localization specified by
|
|
prtGeneralCurrentLocalization.
|
|
Additional information:
|
|
"
|
|
::= { prtInputEntry 18 }
|
|
|
|
|
|
prtinputsecurity OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePon(3),
|
|
ePoff(4),
|
|
ePnotPresent(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates if this input sub-unit has some security
|
|
associated with it.
|
|
Additional information:
|
|
No security mechanism provided."
|
|
::= { prtInputEntry 19 }
|
|
|
|
|
|
prtoutputdefaultindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of prtOutputIndex corresponding to the default
|
|
output sub-unit; that is, this object selects the default
|
|
output destination.
|
|
Additional information:
|
|
LaserJet 5 has only one output bin, a face-down bin
|
|
located at the top of the printer."
|
|
::= { prtGeneralEntry 7 }
|
|
|
|
|
|
prtoutputtype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePunknown(2),
|
|
ePremovableBin(3),
|
|
ePunRemovableBin(4),
|
|
ePcontinuousRollDevice(5),
|
|
ePmailBox(6),
|
|
ePcontinuousFanFold(7)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The type of technology supported by this output sub-unit.
|
|
Additional information:
|
|
LaserJet 5 has only one output bin, a face-down bin
|
|
located at the top of the printer."
|
|
::= { prtOutputEntry 2 }
|
|
|
|
|
|
prtoutputcapacityunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4),
|
|
ePsheets(8),
|
|
ePfeet(16),
|
|
ePmeters(17)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The unit of measurement for use in calculating and relaying
|
|
capacity values for this output sub-unit.
|
|
Additional information:
|
|
A sheet is a single piece of 20 pound paper."
|
|
::= { prtOutputEntry 3 }
|
|
|
|
|
|
prtoutputmaxcapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum capacity of this output sub-unit in output
|
|
sub-unit capacity units (CapacityUnit). There is no
|
|
convention associated with the media itself so this value
|
|
essentially reflects claimed capacity. If this output
|
|
sub-unit can reliably sense this value, the value is
|
|
sensed by the printer and may not be changed by management
|
|
requests; otherwise, the value may be written
|
|
(by a Remote Contol Panel or a Management Application).
|
|
The value (-1) means other and specifically indicates
|
|
that the sub-unit places no restrictions on this parameter.
|
|
The value (-2) means unknown.
|
|
Additional information:
|
|
Note LaserJet 5 can not sense how much is in the output bin, but
|
|
the product specifications say the output bin can hold
|
|
250 sheets."
|
|
::= { prtOutputEntry 4 }
|
|
|
|
|
|
prtoutputremainingcapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The remaining capacity of the possible output sub-unit
|
|
capacity in output sub-unit capacity units (CapacityUnit)
|
|
of this output sub-unit. If this output sub-unit can
|
|
reliably sense this value, the value is sensed by the
|
|
printer and may not be modified by management requests;
|
|
otherwise, the value may be written (by
|
|
a Remote Contol Panel or a Management
|
|
Application). The value (-1) means other and
|
|
specifically indicates that the sub-unit places no
|
|
restrictions on this parameter. The value (-2) means
|
|
unknown. The value (-3) means that the printer knows that
|
|
there remains capacity for at least one unit.
|
|
Additional information:
|
|
LaserJet 5 does not have any sensing on the output bin,
|
|
so it will always report unknown (-2)."
|
|
::= { prtOutputEntry 5 }
|
|
|
|
|
|
prtoutputstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The current status of this output sub-unit.
|
|
The status is an integer that is the sum of 5
|
|
distinct values, Availability, Non-Critical, Critical,
|
|
On-line, and Transitioning. These values are:
|
|
Availability value
|
|
Available and Idle 0 000'b
|
|
Available and Standby 2 010'b
|
|
Available and Active 4 100'b
|
|
Available and Busy 6 110'b
|
|
Unavailable and OnRequest 1 001'b
|
|
Unavailable because Broken 3 011'b
|
|
Unknown 5 101'b
|
|
Non-Critical
|
|
No Non-Critical Alerts 0
|
|
Non-Critical Alerts 8
|
|
Critical
|
|
No Critical Alerts 0
|
|
Critical Alerts 16
|
|
On-Line
|
|
Intended state is On-Line 0
|
|
Intended state is Off-Line 32
|
|
Transitioning
|
|
At intended state 0
|
|
Transitioning to intended state 64
|
|
|
|
Additional information:
|
|
This is the only thing LaserJet 5 can return since it can not sense the output
|
|
tray. 5 is Unknown Status."
|
|
::= { prtOutputEntry 6 }
|
|
|
|
|
|
prtmarkerdefaultindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of prtMarkerIndex corresponding to the
|
|
default markersub-unit; that is, this object selects the
|
|
default marker.
|
|
Additional information:
|
|
LaserJet 5 only has one marker subunit."
|
|
::= { prtGeneralEntry 8 }
|
|
|
|
|
|
prtmarkermarktech OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePunknown(2),
|
|
ePelectrophotographicLED(3),
|
|
ePelectrophotographicLaser(4),
|
|
ePelectrophotographicOther(5),
|
|
ePimpactMovingHeadDotMatrix9pin(6),
|
|
ePimpactMovingHeadDotMatrix24pin(7),
|
|
ePimpactMovingHeadDotMatrixOther(8),
|
|
ePimpactMovingHeadFullyFormed(9),
|
|
ePimpactBand(10),
|
|
ePimpactOther(11),
|
|
ePinkjetAqueous(12),
|
|
ePinkjetSolid(13),
|
|
ePinkjetOther(14),
|
|
ePpen(15),
|
|
ePthermalTransfer(16),
|
|
ePthermalSensitive(17),
|
|
ePthermalDiffusion(18),
|
|
ePthermalOther(19),
|
|
ePelectroerosion(20),
|
|
ePelectrostatic(21),
|
|
ePphotographicMicrofiche(22),
|
|
ePphotographicImagesetter(23),
|
|
ePphotographicOther(24),
|
|
ePionDeposition(25),
|
|
ePeBeam(26),
|
|
ePtypesetter(27)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The type of marking technology used for this marking sub-unit."
|
|
::= { prtMarkerEntry 2 }
|
|
|
|
|
|
prtmarkercounterunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4),
|
|
ePcharacters(5),
|
|
ePlines(6),
|
|
ePimpressions(7),
|
|
ePsheets(8),
|
|
ePdotRow(9),
|
|
ePhours(11),
|
|
ePfeet(16),
|
|
ePmeters(17)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The unit that will be used by the printer when reporting
|
|
counter values for this marking sub-unit. The
|
|
time units of measure are provided for a device like a
|
|
strip recorder that does not or cannot track the physical
|
|
dimensions of the media and does not use characters,
|
|
lines or sheets.
|
|
Additional information:
|
|
Since LaserJet 5 keeps track of pages printed, the
|
|
counter unit will be defined as ePimpressions which would be
|
|
like saying pages printed."
|
|
::= { prtMarkerEntry 3 }
|
|
|
|
|
|
prtmarkerlifecount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The count of the number of units of measure counted during
|
|
the life of printer using units of measure as specified by
|
|
CounterUnit.
|
|
Additional information:
|
|
In LaserJet 5
|
|
the total engine page count is kept in NVRAM however the NVRAM
|
|
value is only updated every 10 impressions.
|
|
NOTE: The value returned by this OID will be incremented every page but
|
|
if power is lost between NVRAM updates, up to 9 impressions of the page
|
|
count may be lost. The counter will be reset to zero after 999999 pages.
|
|
The page count is incremented when a sheet of media is pulled from an input
|
|
tray. A duplex printed sheet will cause this counter to be incremented by
|
|
two."
|
|
::= { prtMarkerEntry 4 }
|
|
|
|
|
|
prtmarkerpoweroncount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The count of the number of units of measure counted since the
|
|
equipment was most recently powered on using units of measure as
|
|
specified by CounterUnit."
|
|
::= { prtMarkerEntry 5 }
|
|
|
|
|
|
prtmarkerprocesscolorants OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of process colors supported by this marker. A
|
|
process color of 1 implies monochrome. The value of this
|
|
object and SpotColorants cannot both be 0. Must be 0 or
|
|
greater."
|
|
::= { prtMarkerEntry 6 }
|
|
|
|
|
|
prtmarkerspotcolorants OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of spot colors supported by this marker. The
|
|
value of this object and ProcessColorants cannot
|
|
both be 0. Must be 0 or greater."
|
|
::= { prtMarkerEntry 7 }
|
|
|
|
|
|
prtmarkeraddressabilityunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The unit of measure of distances.
|
|
Additional information:
|
|
This will always be ePtenThousandthsOfInches, no matter
|
|
what COLD-RESET-MEDIA-SIZE is because we are talking about
|
|
resolution and toner addressability, which is always dpi"
|
|
::= { prtMarkerEntry 8 }
|
|
|
|
|
|
prtmarkeraddressabilityfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of addressable marking positions in the feed
|
|
direction per 10000 units of measure specified by
|
|
AddressabilityUnit. A value of (-1) implies 'other' or
|
|
'infinite' while a value of (-2) implies 'unknown'.
|
|
Additional information:
|
|
Use this object to specify resolution. LaserJet 5
|
|
supports 300 or 600 dots per inch with 600 being the default."
|
|
::= { prtMarkerEntry 9 }
|
|
|
|
|
|
prtmarkeraddressabilityxfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of addressable marking positions in the cross
|
|
feed direction in 10000 units of measure specified by
|
|
AddressabilityUnit. A value of (-1) implies 'other' or
|
|
'infinite' while a value of (-2) implies 'unknown'.
|
|
Additional information:
|
|
Use this object to specify resolution. LaserJet 5
|
|
supports 300 or 600 dots per inch with 600 being the default."
|
|
::= { prtMarkerEntry 10 }
|
|
|
|
|
|
prtmarkernorthmargin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The margin, in units identified by AddressabilityUnit,
|
|
from the leading edge of the medium as the medium flows
|
|
throught the marking engine with the side to be imaged
|
|
facing the observer. The leading edge is the North edge
|
|
and the other edges are defined by the normal compass
|
|
layout of directions with the compass facing the
|
|
observer. Printing within the area bounded by all four
|
|
margins is guaranteed for all interpreters. The value
|
|
(-2) means unknown."
|
|
::= { prtMarkerEntry 11 }
|
|
|
|
|
|
prtmarkersouthmargin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The margin from the South edge (see NorthMargin)
|
|
of the medium in units identified by
|
|
AddressabilityUnit. Printing within the area bounded by
|
|
all four margins is guaranteed for all interpreters.
|
|
The value (-2) means unknown."
|
|
::= { prtMarkerEntry 12 }
|
|
|
|
|
|
prtmarkerwestmargin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The margin from the West edge (see NorthMargin) of the
|
|
medium in units identified by AddressabilityUnit.
|
|
Printing within the area bouned by all four margins is
|
|
guaranteed for all interpreters. The value (-2) means
|
|
unknown."
|
|
::= { prtMarkerEntry 13 }
|
|
|
|
|
|
prtmarkereastmargin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The margin from the East edge (see NorthMargin) of the
|
|
medium in units identified by AddressabilityUnit.
|
|
Printing within the area bounded by all four margins is
|
|
guaranteed for all interpreters. The value (-2) means
|
|
unknown."
|
|
::= { prtMarkerEntry 14 }
|
|
|
|
|
|
prtmarkerstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The current status of this marker sub-unit.
|
|
The status is an integer that is the sum of 5
|
|
distinct values, Availability, Non-Critical, Critical,
|
|
On-line, and Transitioning. These values are:
|
|
Availability value
|
|
Available and Idle 0 000'b
|
|
Available and Standby 2 010'b
|
|
Available and Active 4 100'b
|
|
Available and Busy 6 110'b
|
|
Unavailable and OnRequest 1 001'b
|
|
Unavailable because Broken 3 011'b
|
|
Unknown 5 101'b
|
|
Non-Critical
|
|
No Non-Critical Alerts 0
|
|
Non-Critical Alerts 8
|
|
Critical
|
|
No Critical Alerts 0
|
|
Critical Alerts 16
|
|
On-Line
|
|
Intended state is On-Line 0
|
|
Intended state is Off-Line 32
|
|
Transitioning
|
|
At intended state 0
|
|
Transitioning to intended state 64 "
|
|
::= { prtMarkerEntry 15 }
|
|
|
|
|
|
prtmarkersuppliesmarkerindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of prtMarkerIndex corresponding to the
|
|
marking sub-unit with which this marker supply
|
|
sub-unit is associated.
|
|
Additional information:
|
|
LaserJet 5 has just one marker supply, the toner
|
|
cartridge, so this value is always 1."
|
|
::= { prtMarkerSuppliesEntry 2 }
|
|
|
|
|
|
prtmarkersuppliescolorantindex OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of prtMarkerColorantIndex
|
|
corresponding to the colorant with which this
|
|
marker supply sub-unit is associated. This value
|
|
shall be 0 if there is no colorant table."
|
|
::= { prtMarkerSuppliesEntry 3 }
|
|
|
|
|
|
prtmarkersuppliesclass OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePsupplyThatIsConsumed(3),
|
|
ePreceptacleThatIsFilled(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates whether this supply entity represents a supply
|
|
container that is consumed or a receptacle that is filled."
|
|
::= { prtMarkerSuppliesEntry 4 }
|
|
|
|
|
|
prtmarkersuppliestype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePunknown(2),
|
|
ePtoner(3),
|
|
ePwasteToner(4),
|
|
ePink(5),
|
|
ePinkCartridge(6),
|
|
ePinkRibbon(7),
|
|
ePwasteInk(8),
|
|
ePopc(9),
|
|
ePdeveloper(10),
|
|
ePfuserOil(11),
|
|
ePsolidWax(12),
|
|
ePribbonWax(13),
|
|
ePwasteWax(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The type of this supply."
|
|
::= { prtMarkerSuppliesEntry 5 }
|
|
|
|
|
|
prtmarkersuppliesdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The description of this supply container/receptacle in the
|
|
localization specified by prtGeneralCurrentLocalization."
|
|
::= { prtMarkerSuppliesEntry 6 }
|
|
|
|
|
|
prtmarkersuppliessupplyunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4),
|
|
ePthousandthsOfOunces(12),
|
|
ePtenthsOfGrams(13),
|
|
ePhundrethsOfFluidOunces(14),
|
|
ePtenthsOfMilliliters(15)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Unit of this marker supply container/receptacle."
|
|
::= { prtMarkerSuppliesEntry 7 }
|
|
|
|
|
|
prtmarkersuppliesmaxcapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum capacity of this supply container/receptacle
|
|
expressed in SupplyUnit. If this supply
|
|
container/receptacle can reliably sense this value, the
|
|
value is sensed by the printer and is read-only;
|
|
otherwise, the value may be written (by a Remote Contol
|
|
Panel or a Management Application). The value (-1) means
|
|
other and specifically indicates that the sub-unit places
|
|
no restrictions on this parameter. The value (-2) means
|
|
unknown.
|
|
Additional information:
|
|
LaserJet 5 cannot sense how much toner is left, it just
|
|
senses when the toner reaches a certain low level."
|
|
::= { prtMarkerSuppliesEntry 8 }
|
|
|
|
|
|
prtmarkersupplieslevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The current level if this supply is a container; the
|
|
remaining space if this supply is a receptacle. If this
|
|
supply container/receptacle can reliably sense this
|
|
value, the value is sensed by the printer and is
|
|
read-only; otherwise, the value may be written (by a
|
|
Remote Contol Panel or a Management Application). The
|
|
value (-1) means other and specifically indicates that
|
|
the sub-unit places no restrictions on this parameter.
|
|
The value (-2) means unknown. A value of (-3) means that the
|
|
printer knows that there is some supply/remaining space,
|
|
respectively.
|
|
Additional information:
|
|
LaserJet 5 detects the toner level as being either
|
|
above or below the 'LOW' sensor. Therefore, a value
|
|
of -3 is returned when the level is above the 'LOW'
|
|
sensor and a value of -2 is returned when the toner
|
|
cartridge detects the 'LOW' condition."
|
|
::= { prtMarkerSuppliesEntry 9 }
|
|
|
|
|
|
prtmediapathdefaultindex OBJECT-TYPE
|
|
SYNTAX INTEGER(1..3)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of prtMediaPathIndex corresponding to
|
|
the default media path; that is, the selection of the
|
|
default media path.
|
|
Additional information:
|
|
If the duplex unit is not installed, the only valid
|
|
value for this object is 1; with duplex unit installed, 1-3 values are
|
|
valid. 1 is simplex, 2 is LongEdgeBindingDuplex, and 3 is ShortEdgeBindingDuplex.
|
|
If the printer is not idle, he new value of this object may not take effect
|
|
until a job boundary is reached. If a get is done on this object before the
|
|
job boundary is reached, the value last set will be returned."
|
|
::= { prtGeneralEntry 9 }
|
|
|
|
|
|
prtmediapathmaxspeedprintunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInchesPerHour(3),
|
|
ePmicrometersPerHour(4),
|
|
ePcharactersPerHour(5),
|
|
ePlinesPerHour(6),
|
|
ePimpressionsPerHour(7),
|
|
ePsheetsPerHour(8),
|
|
ePdotRowPerHour(9),
|
|
ePfeetPerHour(16),
|
|
ePmetersPerHour(17)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The unit of measure used in specifying the speed of all media
|
|
paths in the printer."
|
|
::= { prtMediaPathEntry 2 }
|
|
|
|
|
|
prtmediapathmediasizeunit OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePtenThousandthsOfInches(3),
|
|
ePmicrometers(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The units of measure of media size for use in calculating and
|
|
relaying dimensional values for all media paths in the printer."
|
|
::= { prtMediaPathEntry 3 }
|
|
|
|
|
|
prtmediapathmaxspeed OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum printing speed of this media path expressed in
|
|
prtMediaPathMaxSpeedUnit's. A value of (-1) implies
|
|
'other'.
|
|
Additional information:
|
|
The page size for this performance is 8.5x11. The
|
|
duplex speed is based on 6.4 ppm."
|
|
::= { prtMediaPathEntry 4 }
|
|
|
|
|
|
prtmediapathmaxmediafeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum physical media size in the feed direction of this
|
|
media path expressed in units of measure specified by
|
|
MediaSizeUnit. A value of (-1) implies 'unlimited'. A value
|
|
of (-2) implies 'unknown'
|
|
Additional information:
|
|
The value returned by this object depends on the value
|
|
of prtMediaPathMediaSizeUnit. It is 140000 if prtInputDimUnit is
|
|
ePtenThousandthsOfInches or 355600 if prtInputDimUnit is ePmicrometers."
|
|
::= { prtMediaPathEntry 5 }
|
|
|
|
|
|
prtmediapathmaxmediaxfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum physical media size across the feed direction of
|
|
this media path expressed in units of measure specified by
|
|
MediaSizeUnit. A value of (-2) implies 'unknown'.
|
|
Additional information:
|
|
The value returned by this object depends on the value
|
|
of prtMediaPathMediaSizeUnit. It is 85000 if prtInputDimUnit is
|
|
ePtenThousandthsOfInches or 216000 if prtInputDimUnit is ePmicrometers."
|
|
::= { prtMediaPathEntry 6 }
|
|
|
|
|
|
prtmediapathminmediafeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The minimum physical media size in the feed direction of this
|
|
media path expressed in units of measure specified by
|
|
MediaSizeUnit. A value of (-2) implies 'unknown'.
|
|
Additional information:
|
|
The value returned by this object depends on the value
|
|
of prtMediaPathMediaSizeUnit. It is 63000 if prtInputDimUnit is
|
|
ePtenThousandthsOfInches or 160000 if prtInputDimUnit is ePmicrometers."
|
|
::= { prtMediaPathEntry 7 }
|
|
|
|
|
|
prtmediapathminmediaxfeeddir OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The minimum physical media size across the feed direction of
|
|
this media path expressed in units of measure specified by
|
|
MediaSizeUnit. A value of (-2) implies 'unknown'.
|
|
Additional information:
|
|
The value returned by this object depends on the value
|
|
of prtMediaPathMediaSizeUnit. It is 35000 if prtInputDimUnit is
|
|
ePtenThousandthsOfInches or 90000 if prtInputDimUnit is ePmicrometers. This size corresponds to a Monarch envelope. "
|
|
::= { prtMediaPathEntry 8 }
|
|
|
|
|
|
prtmediapathtype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePlongEdgeBindingDuplex(3),
|
|
ePshortEdgeBindingDuplex(4),
|
|
ePsimplex(5)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The type of the media path for this media path. "
|
|
::= { prtMediaPathEntry 9 }
|
|
|
|
|
|
prtmediapathdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The manufacturer-provided description of this media path in
|
|
the localization specified by prtGeneralCurrentLocalization."
|
|
::= { prtMediaPathEntry 10 }
|
|
|
|
|
|
prtmediapathstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The current status of this media path.
|
|
The status is an integer that is the sum of 5
|
|
distinct values, Availability, Non-Critical, Critical,
|
|
On-line, and Transitioning. These values are:
|
|
Availability value
|
|
Available and Idle 0 000'b
|
|
Available and Standby 2 010'b
|
|
Available and Active 4 100'b
|
|
Available and Busy 6 110'b
|
|
Unavailable and OnRequest 1 001'b
|
|
Unavailable because Broken 3 011'b
|
|
Unknown 5 101'b
|
|
Non-Critical
|
|
No Non-Critical Alerts 0
|
|
Non-Critical Alerts 8
|
|
Critical
|
|
No Critical Alerts 0
|
|
Critical Alerts 16
|
|
On-Line
|
|
Intended state is On-Line 0
|
|
Intended state is Off-Line 32
|
|
Transitioning
|
|
At intended state 0
|
|
Transitioning to intended state 64
|
|
|
|
Additional information:
|
|
The default values assume the printer is idle."
|
|
::= { prtMediaPathEntry 11 }
|
|
|
|
|
|
prtchanneltype OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePchSerialPort(3),
|
|
ePchIEEE1284Port(5),
|
|
ePchAppleTalkPAP(7),
|
|
ePchNetwarePServer(10),
|
|
ePchPort9100(11),
|
|
ePchDLCLLCPort(15)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The type of this print data channel. This
|
|
object provides the linkage to ChannelType-specific
|
|
groups that may (conceptually) extend the prtChannelTable
|
|
with additional details about that channel.
|
|
Additional information:
|
|
MIO-based channels provide their own values."
|
|
::= { prtChannelEntry 2 }
|
|
|
|
|
|
prtchannelprotocolversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..63))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The version of the protocol used on this
|
|
channel. The format used for version numbering depends
|
|
on prtChannelType.
|
|
Additional information:
|
|
MIO-based channels provide
|
|
their own values.
|
|
The channel 1 value includes (separated by semi colons) different aspects
|
|
of the spec: electrical: logical; and physical connector."
|
|
::= { prtChannelEntry 3 }
|
|
|
|
|
|
prtchannelcurrentjobcntllangindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of prtInterpreterIndex corresponding to the
|
|
Control Language Interpreter for this channel. This
|
|
interpreter defines the syntax used for control
|
|
functions, such as querying or changing environment
|
|
variables and identifying job boundaries (e.g. PJL,
|
|
PostScript, NPAP). Must be 1 or greater.
|
|
Additional information:
|
|
This object points to the PJL language. It is
|
|
read-only because PJL is the printer's only job
|
|
control language."
|
|
::= { prtChannelEntry 4 }
|
|
|
|
|
|
prtchanneldefaultpagedesclangindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of prtInterpreterIndex corresponding to the
|
|
Page Description Language Interpreter for this channel.
|
|
This interpreter defines the default Page Description
|
|
Language interpreter to be used for the print data unless
|
|
the Control Language is used to select a specific
|
|
interpreter (e.g., PCL, PostScript Language,
|
|
auto-sense). Must be 1 or greater.
|
|
Additional information:
|
|
The default points to the automatic language switcher. If this
|
|
object is changed for one channel, all channels will be changed."
|
|
::= { prtChannelEntry 5 }
|
|
|
|
|
|
prtchannelstate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePprintDataAccepted(3),
|
|
ePnoDataAccepted(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The state of this print data channel. The value determines
|
|
whether control information and print data is allowed through
|
|
this channel or not.
|
|
Additional information:
|
|
MIO-based channels provide their own values for this
|
|
object. The base-printer's ports always report a value of ePprintDataAccepted.
|
|
If the printer is offline, that is detected by reading the Host Resources
|
|
General Printer Status objects, not by reading this object."
|
|
::= { prtChannelEntry 6 }
|
|
|
|
|
|
prtchannelifindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of ifIndex (in the ifTable; see the interface
|
|
section of MIB-2/RFC 1213) which corresponds to this channel.
|
|
When more than one row of the ifTable is relevant, this is
|
|
the index of the row representing the topmost layer in the
|
|
interface hierarchy. A value of zero indicates that no
|
|
interface is associated with this channel.
|
|
Additional information:
|
|
MIO-based channels provide their own values for this
|
|
object."
|
|
::= { prtChannelEntry 7 }
|
|
|
|
|
|
prtchannelstatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The current status of the channel.
|
|
The status is an integer that is the sum of 5
|
|
distinct values, Availability, Non-Critical, Critical,
|
|
On-line, and Transitioning. These values are:
|
|
Availability value
|
|
Available and Idle 0 000'b
|
|
Available and Standby 2 010'b
|
|
Available and Active 4 100'b
|
|
Available and Busy 6 110'b
|
|
Unavailable and OnRequest 1 001'b
|
|
Unavailable because Broken 3 011'b
|
|
Unknown 5 101'b
|
|
Non-Critical
|
|
No Non-Critical Alerts 0
|
|
Non-Critical Alerts 8
|
|
Critical
|
|
No Critical Alerts 0
|
|
Critical Alerts 16
|
|
On-Line
|
|
Intended state is On-Line 0
|
|
Intended state is Off-Line 32
|
|
Transitioning
|
|
At intended state 0
|
|
Transitioning to intended state 64
|
|
|
|
Additional information:
|
|
MIO-based channels provide their own values for this
|
|
object."
|
|
::= { prtChannelEntry 8 }
|
|
|
|
|
|
prtinterpreterlangfamily OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePlangPCL(3),
|
|
ePlangPJL(5),
|
|
ePlangPS(6),
|
|
ePlangAutomatic(37),
|
|
ePlangPCLXL(47)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The family name of a Page Description Language (PDL) or
|
|
control language which this interpreter in the printer can
|
|
interpret or emulate. This type 2 list of enumerations
|
|
requires review before additional entries are made.
|
|
Additional information:
|
|
Also provides a place to supply PJL information and
|
|
overall ROM information (by using the language
|
|
switcher as a separate language)."
|
|
::= { prtInterpreterEntry 2 }
|
|
|
|
|
|
prtinterpreterlanglevel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The level of the language which this interpreter is
|
|
interpreting or emulating. This might contain a value like
|
|
'5e' for an interpreter which is emulating level 5e of the PCL
|
|
language. It might contain '2' for an interpreter which is
|
|
emulating level 2 of the PostScript language. Similarly it
|
|
might contain '2' for an interpreter which is emulating level
|
|
2 of the HPGL language. "
|
|
::= { prtInterpreterEntry 3 }
|
|
|
|
|
|
prtinterpreterlangversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The date code or version of the language which this interpreter
|
|
is interpreting or emulating.
|
|
Additional information:
|
|
For PostScript, this is more detailed revision info."
|
|
::= { prtInterpreterEntry 4 }
|
|
|
|
|
|
prtinterpreterdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A string to identify this interpreter in the localization
|
|
specified by prtGeneralCurrentLocalization as opposed to the
|
|
language which is being interpreted. It is anticipated that
|
|
this string will allow manufacturers to unambiguously identify
|
|
their interpreters.
|
|
Additional information:
|
|
None of these strings are localized."
|
|
::= { prtInterpreterEntry 5 }
|
|
|
|
|
|
prtinterpreterversion OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..31))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The date code, version number, or other product specific
|
|
information tied to this interpreter. This value is
|
|
associated with the interpreter, rather than with the version
|
|
of the language which is being interpreted or emulated.
|
|
Additional information:
|
|
Same as prtInterpreterLangVersion."
|
|
::= { prtInterpreterEntry 6 }
|
|
|
|
|
|
prtinterpreterdefaultorientation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePportrait(3),
|
|
ePlandscape(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The current orientation default for this interpreter. This
|
|
value may be overridden for a particular job (e.g., by a
|
|
command in the input data stream).
|
|
Additional information:
|
|
Interpreters 1 and 2 ignore the value of this object.
|
|
The values for PCL and PostScript are either ePportrait or ePlandscape;
|
|
attempting to set them to a different value will cause
|
|
<badValue> to be returned. Setting this object for one
|
|
interpreter will change it for all installed interpreters."
|
|
::= { prtInterpreterEntry 7 }
|
|
|
|
|
|
prtinterpreterfeedaddressability OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum interpreter addressability in the feed
|
|
direction in 10000 prtMarkerAddressabilityUnit s (see
|
|
prtMarkerAddressabilityFeedDir ) for this interpreter.
|
|
The value (-1) means other and specifically indicates
|
|
that the sub-unit places no restrictions on this parameter."
|
|
::= { prtInterpreterEntry 8 }
|
|
|
|
|
|
prtinterpreterxfeedaddressability OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The maximum interpreter addressability in the cross feed
|
|
direction in 10000 prtMarkerAddressabilityUnit s (see
|
|
prtMarkerAddressabilityXFeedDir) for this interpreter.
|
|
The value (-1) means other and specifically indicates
|
|
that the sub-unit places no restrictions on this
|
|
parameter."
|
|
::= { prtInterpreterEntry 9 }
|
|
|
|
|
|
prtinterpreterdefaultcharsetin OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePcsASCII(3),
|
|
ePcsISOLatin1(4),
|
|
ePcsISOLatin2(5),
|
|
ePcsISOLatinArabic(9),
|
|
ePcsISOLatin5(12),
|
|
ePcsISOLatin6(13),
|
|
ePcsISO4UnitedKingdom(20),
|
|
ePcsISO11SwedishforNames(21),
|
|
ePcsISO15Italian(22),
|
|
ePcsISO17Spanish(23),
|
|
ePcsISO21German(24),
|
|
ePcsISO60DanishNorwegian(25),
|
|
ePcsISO69French(26),
|
|
ePcsUnicodeIBM2039(1004),
|
|
ePcsWindows30Latin1(2000),
|
|
ePcsWindows31Latin1(2001),
|
|
ePcsWindows31Latin2(2002),
|
|
ePcsWindows31Latin5(2003),
|
|
ePcsHPRoman8(2004),
|
|
ePcsAdobeStandardEncoding(2005),
|
|
ePcsPC850Multilingual(2009),
|
|
ePcsPCp852(2010),
|
|
ePcsPC8CodePage437(2011),
|
|
ePcsPC8DNDanishNorwegian(2012),
|
|
ePcsHPPC8Turkish(2014),
|
|
ePcsHPLegal(2017),
|
|
ePcsHPDeskTop(2021),
|
|
ePcsMacintosh(2027)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The default coded character set for input octets
|
|
encountered outside a context in which the Page
|
|
Description Language established the interpretation
|
|
of the octets.
|
|
This value shall be (2) if there is no default.
|
|
Additional information:
|
|
ePcsAdobeStandardEncoding is the same as PSText(10J).
|
|
The object corresponding to PCL has read-write acces; all others
|
|
are read-only.
|
|
the above list corresponds to the following symbol sets as they
|
|
appear on the Control Panel:
|
|
ePother( 1) - used if designated coded char. set not in list
|
|
ePcsASCII( 3) - ISO-6
|
|
ePcsISOLatin1( 4) - ISO L1
|
|
ePcsISOLatin2( 5) - IS L2
|
|
ePcsISOLatinArabic(9) - WINBALT
|
|
ePcsISOLatin5( 12) - ISO L5
|
|
ePcsISOLatin6( 13) - ISO L6
|
|
ePcsISO4UnitedKingdom( 20) - ISO-4
|
|
ePcsISO11SwedishforNames( 21) - ISO-11
|
|
ePcsISO15Italian( 22) - ISO-15
|
|
ePcsISO17Spanish( 23) - ISO-17
|
|
ePcsISO21German( 24) - ISO-21
|
|
ePcsISO60DanishNorwegian( 25) - ISO-60
|
|
ePcsISO69French( 26) - ISO-69
|
|
ePcsUnicodeIBM2039(1004) - PC-1004
|
|
ePcsWindows30Latin1( 2000) - WIN 3.0
|
|
ePcsWindows31Latin1( 2001) - WIN L1
|
|
ePcsWindows31Latin2( 2002) - WIN L2
|
|
ePcsWindows31Latin5( 2003) - WIN L5
|
|
ePcsHPRoman8( 2004) - ROMAN-8
|
|
ePcsAdobeStandardEncoding( 2005) - PS TEXT
|
|
ePcsPC850Multilingual( 2009) - PC-850
|
|
ePcsPCp852( 2010) - PC-852
|
|
ePcsPC8CodePage437( 2011) - PC-8
|
|
ePcsPC8DNDanishNorwegian( 2012) - PC-8DN
|
|
ePcsHPPC8Turkish( 2014) - PC-8 TK
|
|
ePcsHPLegal( 2017) - LEGAL
|
|
ePcsHPDeskTop( 2021) - DESKTOP
|
|
ePcsMacintosh(2027) - MC TEXT
|
|
"
|
|
::= { prtInterpreterEntry 10 }
|
|
|
|
|
|
prtinterpreterdefaultcharsetout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePcsNoDefault(2),
|
|
ePcsASCII(3),
|
|
ePcsHPRoman8(2004),
|
|
ePcsAdobeStandardEncoding(2005)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The default character set for data coming from this interpreter
|
|
through the printer's output channel.
|
|
This value shall be (2) if there is no default."
|
|
::= { prtInterpreterEntry 11 }
|
|
|
|
|
|
prtinterpretertwoway OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePyes(3),
|
|
ePno(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"Indicates whether or not this interpreter returns information
|
|
back to the host."
|
|
::= { prtInterpreterEntry 12 }
|
|
|
|
|
|
prtconsolelocalization OBJECT-TYPE
|
|
SYNTAX INTEGER(1..13)
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The value of the prtLocalizationIndex corresponding to
|
|
the language, country, and character set to be used for the
|
|
console. This localization applies both to the actual display
|
|
on the console as well as the encoding of these console
|
|
objects in management operations.
|
|
Additional information:
|
|
The value of this object is saved in NVRAM.
|
|
If a localized string is currently being displayed on the control panel by the
|
|
device, changing this object will cause the displayed string to be changed
|
|
to its new value. If this object is changed while the printer is processing
|
|
a page that contains localized strings, the results are undefined."
|
|
::= { prtGeneralEntry 10 }
|
|
|
|
|
|
prtconsolenumberofdisplaylines OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of lines on the printer's physical
|
|
display. This value is 0 if there are no lines on the
|
|
physical display or if there is no physical display."
|
|
::= { prtGeneralEntry 11 }
|
|
|
|
|
|
prtconsolenumberofdisplaychars OBJECT-TYPE
|
|
SYNTAX INTEGER(0..65535)
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The number of characters per line displayed on the physical
|
|
display. This value is 0 if there are no lines on the
|
|
physical display or if there is no physical display
|
|
Additional information:
|
|
LaserJet 5 messages may
|
|
scroll so even thought the Display size is 16 characters, messages may contain
|
|
up to 40 characters."
|
|
::= { prtGeneralEntry 12 }
|
|
|
|
|
|
prtconsoledisable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePenabled(3),
|
|
ePdisabled(4)
|
|
}
|
|
ACCESS read-write
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"This object enables or disables manual input from the
|
|
operators console.
|
|
Additional information:
|
|
Service Mode is not disabled by this object.
|
|
If the object prtConsoleDisable has value 'disabled then manual input is not
|
|
accepted from the operator console. If the object prtConsoleDisable has the
|
|
value 'enabled' then manual input is accepted from the operator console."
|
|
::= { prtGeneralEntry 13 }
|
|
|
|
|
|
prtconsoledisplaybuffertext OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The content of a line in the logical display buffer of
|
|
the operator's console of the printer. When a write
|
|
operation occurs, normally a critical message, to one of
|
|
the LineText strings, the agent should make that line
|
|
displayable if a physical display is present. Writing
|
|
a zero length string clears the line. It is an
|
|
implementation-specific matter as to whether the agent allows
|
|
a line to be overwritten before it has been cleared.
|
|
Printer generated strings shall be in the localization
|
|
specified by ConsoleLocalization. Management Application
|
|
generated strings should be localized by the Management
|
|
Application.
|
|
Additional information:
|
|
The object BACKGROUND-STATUS-MSG-LINE1-PART1 should
|
|
be used to write messages to the control panel display"
|
|
::= { prtConsoleDisplayBufferEntry 2 }
|
|
|
|
|
|
prtconsoleontime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The on time in milliseconds of blinking of this light; 0
|
|
indicates off always. If both prtConsoleOnTime
|
|
and prtConsoleOffTime are 0, then the light is
|
|
always off.
|
|
Additional information:
|
|
LaserJet 5 does not have any LEDs."
|
|
::= { prtConsoleLightEntry 2 }
|
|
|
|
|
|
prtconsoleofftime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The off time in milliseconds of blinking of this light; 0
|
|
indicates on always. If both prtConsoleOnTime
|
|
and prtConsoleOffTime are 0, then the light is
|
|
always off.
|
|
Additional information:
|
|
LaserJet 5 does not have any LEDs."
|
|
::= { prtConsoleLightEntry 3 }
|
|
|
|
|
|
prtconsolecolor OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePunknown(2),
|
|
ePwhite(3),
|
|
ePred(4),
|
|
ePgreen(5),
|
|
ePblue(6),
|
|
ePcyan(7),
|
|
ePmagenta(8),
|
|
ePyellow(9)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The color of this light.
|
|
Additional information:
|
|
LaserJet 5 does not have any LEDs."
|
|
::= { prtConsoleLightEntry 4 }
|
|
|
|
|
|
prtconsoledescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The vendor description or label of this light in the
|
|
localization specified by prtConsoleLocalization.
|
|
Additional information:
|
|
LaserJet 5 does not have any LEDs."
|
|
::= { prtConsoleLightEntry 5 }
|
|
|
|
|
|
prtalertseveritylevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePcritical(3),
|
|
ePwarning(4)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The level of severity of this alert table entry. The printer
|
|
determines the severity level assigned to each entry into the
|
|
table."
|
|
::= { prtAlertEntry 2 }
|
|
|
|
|
|
prtalerttraininglevel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePuntrained(3),
|
|
ePtrained(4),
|
|
ePfieldService(5),
|
|
ePmanagement(6)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The level of training required to handle this alert. The
|
|
training level is an enumeration that is determined and
|
|
assigned by the printer manufacturer based on the information
|
|
or the training required to handle this alert. The printer
|
|
will break alerts into these different training levels. It is
|
|
the responsibility of the management application in the system
|
|
to determine how a particular alert is handled and how and to
|
|
whom that alert is routed. The following are the four
|
|
training levels of alerts:
|
|
Field Service - Alerts that typically require advanced
|
|
training and technical knowledge of the printer
|
|
and its sub-units. An example of a technical
|
|
person would be a manufacture's Field Service
|
|
representative, or other person formally
|
|
trained by the manufacturer or similar
|
|
representative.
|
|
Trained - Alerts that require an intermediate or moderate
|
|
level of knowledge of the printer and its
|
|
sub-units. A typical examples of alerts that
|
|
a trained operator can handle is replacing
|
|
toner cartridges.
|
|
Untrained - Alerts that can be fixed without prior
|
|
training either because the action to correct
|
|
the alert is obvious or the printer can help the
|
|
untrained person fix the problem. A typical
|
|
example of such an alert is reloading paper
|
|
trays and emptying output bins on a low end
|
|
printer.
|
|
Management - Alerts that have to do with overall
|
|
operation of and configuration of the printer.
|
|
Examples of management events are configuration
|
|
change of sub-units.
|
|
Additional information:
|
|
The value of this object depends on the alert
|
|
condition as follows:
|
|
ePuntrained: Paper low/out.
|
|
ePtrained: Toner low.
|
|
ePfieldService: Marker failure.
|
|
ePmanagement: Configuration change."
|
|
::= { prtAlertEntry 3 }
|
|
|
|
|
|
prtalertgroup OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePgeneralPrinter(5),
|
|
ePcover(6),
|
|
ePinput(8),
|
|
ePoutput(9),
|
|
ePmarker(10),
|
|
ePchannel(14)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The type of sub-unit within the printer model that this alert
|
|
is related. Input, output, and markers are examples of
|
|
printer model groups, i.e., examples of types of sub-units.
|
|
Whereever possible, these enumerations match the
|
|
sub-identifier that identifies the relevant table in the
|
|
printmib."
|
|
::= { prtAlertEntry 4 }
|
|
|
|
|
|
prtalertgroupindex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"An index of the row within the principle table in the
|
|
group identified by prtAlertGroup that represents the
|
|
sub-unit of the printer that caused this alert. The
|
|
combination of the Group and the GroupIndex defines
|
|
exactly which printer sub-unit caused the alert.; for
|
|
example, Input #3, Output #2, and Marker #1.
|
|
Every object in this MIB is indexed with hrDeviceIndex and
|
|
optionally, another index variable. If this other index
|
|
variable is present in the table that generated the alert, it
|
|
will be used as the value for this object. Otherwise, this
|
|
value shall be -1."
|
|
::= { prtAlertEntry 5 }
|
|
|
|
|
|
prtalertlocation OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The sub-unit location that is defined by the printer
|
|
manufacturer to further refine the location of this alert
|
|
within the designated sub-unit. The location is used in
|
|
conjunction with the Group and GroupIndex values; for
|
|
example, there is an alert in Input #2 at location number 7."
|
|
::= { prtAlertEntry 6 }
|
|
|
|
|
|
prtalertcode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ePother(1),
|
|
ePjam(8),
|
|
ePdoorOpenAlert(501),
|
|
ePinputMediaTrayMissing(801),
|
|
ePinputMediaSupplyEmpty(808),
|
|
ePmarkerFuserUnderTemperature(1001),
|
|
ePmarkerFuserOverTemperature(1002),
|
|
ePmarkerTonerEmpty(1101),
|
|
ePmarkerTonerAlmostEmpty(1104)
|
|
}
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"The code that describes the type of alert for this entry in
|
|
the table. There are different codes for each
|
|
sub-unit type: for example, Media Supply Low and Media
|
|
Supply Empty are Aler codes for the Input sub-unit."
|
|
::= { prtAlertEntry 7 }
|
|
|
|
|
|
prtalertdescription OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..255))
|
|
ACCESS read-only
|
|
STATUS optional
|
|
DESCRIPTION
|
|
"A description of this alert entry in the localization
|
|
specified by prtGeneralCurrentLocalization. The description is
|
|
provided by the printer to further elaborate on the enumerated
|
|
alert or provide information in the case where the code is
|
|
classified ask `other' or `unknown'. The printer is required
|
|
to return a description string but the string may be a null
|
|
string."
|
|
::= { prtAlertEntry 8 }
|
|
|
|
|
|
END
|