Observium_CE/mibs/hp/LJ521-MIB

10117 lines
397 KiB
Plaintext
Raw Blame History

-- (C) COPYRIGHT HEWLETT-PACKARD COMPANY 2014.
--
-- LaserJet 521 Printer Model Specific MIB.
--
-- Generated on Jun. 05, 2014.
--
-- Company names and product names mentioned herein may be
-- trademarks, and/or registered trademarks of their respective
-- companies.
--
-- For internal and external use.
--
-- This MIB describes all the printer model specific
-- objects supported by the LaserJet 521 printer
-- when networked connected.
--
-- The following MIBs also contain objects supported
-- by a LaserJet 521 printer:
--
-- IEEE 802.11 MIB
-- IEEE 802.1X MIB
-- rfc 2790 Host Resources MIB
-- rfc 3411 SNMP Framework MIB
-- rfc 3412 SNMP MPD MIB
-- rfc 3418 SNMP MIB
-- rfc 3805 Printer MIB
-- rfc 4022 TCP MIB
-- rfc 4293 IP MIB
-- rfc 4113 UDP MIB
-- PWG 5107.1-2005 Printer Port Monitor MIB
--
-- This MIB complies with the following RFCs:
--
-- rfc 1157 Simple Network Management Protocol
-- rfc 2578 Structure of Management Information Version 2
--
-- Notes:
--
-- 1) Objects containing a string which are defined in this MIB use the
-- first two bytes to hold the symbol set used to encode the string.
-- The Roman-8 symbol set has a hex encoding of 0x0115. Other
-- symbol sets are listed in the PCL 5 Comparison Guide in table
-- C-1 Symbol Set Values.
--
-- 2) Some of the objects included are only supported if an accessory
-- is installed. These accessories include:
-- MIO based accessories
-- SIMM based accessories
-- Paper handling accessories
LJ521-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM SNMPv2-TC;
hpPrintServer OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) internet(1) private(4) enterprises(1) 11}
dm OBJECT IDENTIFIER ::= { hpPrintServer nm(2) hpsystem(3) net-peripheral(9) netdm(4) 2}
device OBJECT IDENTIFIER ::= { dm 1 }
system OBJECT IDENTIFIER ::= { device 1 }
settings-system OBJECT IDENTIFIER ::= { system 1 }
source-subsystem OBJECT IDENTIFIER ::= { device 2 }
scanner OBJECT IDENTIFIER ::= { source-subsystem 2 }
status-scanner OBJECT IDENTIFIER ::= { scanner 2 }
copier OBJECT IDENTIFIER ::= { device 5 }
settings-copier OBJECT IDENTIFIER ::= { copier 1 }
status-system OBJECT IDENTIFIER ::= { system 2 }
id OBJECT IDENTIFIER ::= { system 3 }
job OBJECT IDENTIFIER ::= { system 6 }
fax-job-control OBJECT IDENTIFIER ::= { job 3 }
settings-fax-job OBJECT IDENTIFIER ::= { fax-job-control 1 }
status-fax-job OBJECT IDENTIFIER ::= { fax-job-control 2 }
faxjob OBJECT IDENTIFIER ::= { fax-job-control 3 }
faxjob-rx-status OBJECT IDENTIFIER ::= { faxjob 1 }
faxjob-tx-status OBJECT IDENTIFIER ::= { faxjob 3 }
faxjob-tx-error OBJECT IDENTIFIER ::= { faxjob 4 }
faxjob-tx-current-page OBJECT IDENTIFIER ::= { faxjob 5 }
faxjob-rx-current-page OBJECT IDENTIFIER ::= { faxjob 6 }
faxjob-rx-duration OBJECT IDENTIFIER ::= { faxjob 7 }
faxjob-tx-duration OBJECT IDENTIFIER ::= { faxjob 8 }
fax-activity-log OBJECT IDENTIFIER ::= { job 4 }
settings-faxlog OBJECT IDENTIFIER ::= { fax-activity-log 1 }
phone OBJECT IDENTIFIER ::= { system 9 }
dial OBJECT IDENTIFIER ::= { phone 1 }
dial-all-lines OBJECT IDENTIFIER ::= { dial 1 }
answer OBJECT IDENTIFIER ::= { phone 2 }
answer-all-lines OBJECT IDENTIFIER ::= { answer 1 }
fax-receive OBJECT IDENTIFIER ::= { source-subsystem 3 }
settings-fax-receive OBJECT IDENTIFIER ::= { fax-receive 1 }
status-fax-receive OBJECT IDENTIFIER ::= { fax-receive 2 }
processing-subsystem OBJECT IDENTIFIER ::= { device 3 }
fax-proc-sub OBJECT IDENTIFIER ::= { processing-subsystem 7 }
settings-fax-proc-sub OBJECT IDENTIFIER ::= { fax-proc-sub 1 }
status-fax-proc-sub OBJECT IDENTIFIER ::= { fax-proc-sub 2 }
fax-forwarding OBJECT IDENTIFIER ::= { fax-proc-sub 3 }
destination-subsystem OBJECT IDENTIFIER ::= { device 4 }
fax-send OBJECT IDENTIFIER ::= { destination-subsystem 2 }
settings-fax-send OBJECT IDENTIFIER ::= { fax-send 1 }
status-fax-send OBJECT IDENTIFIER ::= { fax-send 2 }
transmit-fax OBJECT IDENTIFIER ::= { fax-send 5 }
hrm OBJECT IDENTIFIER ::= { dm 3 }
hrStorage OBJECT IDENTIFIER ::= { hrm 2 }
hrStorageTable OBJECT IDENTIFIER ::= { hrStorage 3 }
hrStorageEntry OBJECT IDENTIFIER ::= { hrStorageTable 1 }
hrDevice OBJECT IDENTIFIER ::= { hrm 3 }
hrDeviceTable OBJECT IDENTIFIER ::= { hrDevice 2 }
hrDeviceEntry OBJECT IDENTIFIER ::= { hrDeviceTable 1 }
hrPrinterTable OBJECT IDENTIFIER ::= { hrDevice 5 }
hrPrinterEntry OBJECT IDENTIFIER ::= { hrPrinterTable 1 }
iso OBJECT IDENTIFIER ::= { dm 1 }
org OBJECT IDENTIFIER ::= { iso 3 }
dod OBJECT IDENTIFIER ::= { org 6 }
internet OBJECT IDENTIFIER ::= { dod 1 }
private OBJECT IDENTIFIER ::= { internet 4 }
enterprises OBJECT IDENTIFIER ::= { private 1 }
nm OBJECT IDENTIFIER ::= { hpPrintServer 2 }
interface OBJECT IDENTIFIER ::= { nm 4 }
npCard OBJECT IDENTIFIER ::= { interface 3 }
npCRCTable OBJECT IDENTIFIER ::= { npCard 15 }
npCRCEntry OBJECT IDENTIFIER ::= { npCRCTable 1 }
inetTrap OBJECT IDENTIFIER ::= { npCard 22 }
inetTrapDestination OBJECT IDENTIFIER ::= { inetTrap 1 }
inetTrapDestinationTable OBJECT IDENTIFIER ::= { inetTrapDestination 2 }
inetTrapDestinationEntry OBJECT IDENTIFIER ::= { inetTrapDestinationTable 1 }
trap OBJECT IDENTIFIER ::= { nm 13 }
trapDest OBJECT IDENTIFIER ::= { trap 1 }
trapFQDNTable OBJECT IDENTIFIER ::= { trapDest 7 }
trapFQDNEntry OBJECT IDENTIFIER ::= { trapFQDNTable 1 }
snmpAccess OBJECT IDENTIFIER ::= { nm 15 }
community OBJECT IDENTIFIER ::= { snmpAccess 1 }
npSys OBJECT IDENTIFIER ::= { npCard 1 }
npConns OBJECT IDENTIFIER ::= { npCard 4 }
npCfg OBJECT IDENTIFIER ::= { npCard 5 }
npCfgAccessListTable OBJECT IDENTIFIER ::= { npCfg 9 }
npCfgAccessListEntry OBJECT IDENTIFIER ::= { npCfgAccessListTable 1 }
npTcp OBJECT IDENTIFIER ::= { npCard 6 }
npCtl OBJECT IDENTIFIER ::= { npCard 7 }
npPort OBJECT IDENTIFIER ::= { npCard 13 }
npDhcp OBJECT IDENTIFIER ::= { npCard 16 }
npWeb OBJECT IDENTIFIER ::= { npCard 18 }
npSecurity OBJECT IDENTIFIER ::= { npCard 20 }
npSecurityDot11EncryptedWEPKeyTable OBJECT IDENTIFIER ::= { npSecurity 7 }
npSecurityDot11EncryptedWEPKeyEntry OBJECT IDENTIFIER ::= { npSecurityDot11EncryptedWEPKeyTable 1 }
npSecurityDot11SSIDTable OBJECT IDENTIFIER ::= { npSecurity 9 }
npSecurityDot11SSIDEntry OBJECT IDENTIFIER ::= { npSecurityDot11SSIDTable 1 }
system OBJECT IDENTIFIER ::= { nm 3 }
netPeripheral OBJECT IDENTIFIER ::= { system 9 }
netPrinter OBJECT IDENTIFIER ::= { netPeripheral 1 }
generalDeviceStatus OBJECT IDENTIFIER ::= { netPrinter 1 }
netPML OBJECT IDENTIFIER ::= { netPeripheral 4 }
netPMLtrap OBJECT IDENTIFIER ::= { netPML 1 }
npNpi OBJECT IDENTIFIER ::= { npCard 8 }
npNpiPeripheralAttributeEntry OBJECT IDENTIFIER ::= { npNpi 3 }
npNpiCardAttributeEntry OBJECT IDENTIFIER ::= { npNpi 4 }
gdStatusEntry OBJECT IDENTIFIER ::= { generalDeviceStatus 2 }
photo-job OBJECT IDENTIFIER ::= { job 8 }
settings-photo-job OBJECT IDENTIFIER ::= { photo-job 3 }
print-engine OBJECT IDENTIFIER ::= { destination-subsystem 1 }
print-engine-test OBJECT IDENTIFIER ::= { print-engine 9 }
device-configure OBJECT IDENTIFIER ::= { settings-system 32 }
display OBJECT IDENTIFIER ::= { status-system 20 }
display-status OBJECT IDENTIFIER ::= { display 1 }
interface OBJECT IDENTIFIER ::= { system 4 }
simm OBJECT IDENTIFIER ::= { interface 1 }
simm1 OBJECT IDENTIFIER ::= { simm 1 }
test OBJECT IDENTIFIER ::= { system 5 }
settings-job OBJECT IDENTIFIER ::= { job 1 }
active-print-jobs OBJECT IDENTIFIER ::= { job 2 }
job-being-parsed OBJECT IDENTIFIER ::= { active-print-jobs 1 }
job-info OBJECT IDENTIFIER ::= { job 5 }
errorlog OBJECT IDENTIFIER ::= { system 11 }
error1 OBJECT IDENTIFIER ::= { errorlog 1 }
error2 OBJECT IDENTIFIER ::= { errorlog 2 }
error3 OBJECT IDENTIFIER ::= { errorlog 3 }
error4 OBJECT IDENTIFIER ::= { errorlog 4 }
error5 OBJECT IDENTIFIER ::= { errorlog 5 }
error6 OBJECT IDENTIFIER ::= { errorlog 6 }
error7 OBJECT IDENTIFIER ::= { errorlog 7 }
error8 OBJECT IDENTIFIER ::= { errorlog 8 }
error9 OBJECT IDENTIFIER ::= { errorlog 9 }
error10 OBJECT IDENTIFIER ::= { errorlog 10 }
firmware-download OBJECT IDENTIFIER ::= { system 18 }
io OBJECT IDENTIFIER ::= { source-subsystem 1 }
settings-io OBJECT IDENTIFIER ::= { io 1 }
pdl OBJECT IDENTIFIER ::= { processing-subsystem 3 }
settings-pdl OBJECT IDENTIFIER ::= { pdl 1 }
pdl-pcl OBJECT IDENTIFIER ::= { pdl 3 }
pdl-postscript OBJECT IDENTIFIER ::= { pdl 4 }
pdl-pclxl OBJECT IDENTIFIER ::= { pdl 16 }
pjl OBJECT IDENTIFIER ::= { processing-subsystem 5 }
settings-prt-eng OBJECT IDENTIFIER ::= { print-engine 1 }
status-prt-eng OBJECT IDENTIFIER ::= { print-engine 2 }
intray OBJECT IDENTIFIER ::= { print-engine 3 }
settings-intray OBJECT IDENTIFIER ::= { intray 1 }
intrays OBJECT IDENTIFIER ::= { intray 3 }
intray1 OBJECT IDENTIFIER ::= { intrays 1 }
intray2 OBJECT IDENTIFIER ::= { intrays 2 }
intray3 OBJECT IDENTIFIER ::= { intrays 3 }
marking-agent OBJECT IDENTIFIER ::= { print-engine 5 }
settings-marking-agent OBJECT IDENTIFIER ::= { marking-agent 1 }
imaging OBJECT IDENTIFIER ::= { print-engine 6 }
print-media OBJECT IDENTIFIER ::= { print-engine 8 }
settings-print-media OBJECT IDENTIFIER ::= { print-media 1 }
media-info OBJECT IDENTIFIER ::= { print-media 3 }
media1 OBJECT IDENTIFIER ::= { media-info 1 }
media2 OBJECT IDENTIFIER ::= { media-info 2 }
media3 OBJECT IDENTIFIER ::= { media-info 3 }
media4 OBJECT IDENTIFIER ::= { media-info 4 }
media5 OBJECT IDENTIFIER ::= { media-info 5 }
media6 OBJECT IDENTIFIER ::= { media-info 6 }
media8 OBJECT IDENTIFIER ::= { media-info 8 }
media12 OBJECT IDENTIFIER ::= { media-info 12 }
media13 OBJECT IDENTIFIER ::= { media-info 13 }
media14 OBJECT IDENTIFIER ::= { media-info 14 }
media15 OBJECT IDENTIFIER ::= { media-info 15 }
media16 OBJECT IDENTIFIER ::= { media-info 16 }
media17 OBJECT IDENTIFIER ::= { media-info 17 }
media-modes OBJECT IDENTIFIER ::= { print-media 4 }
consumables OBJECT IDENTIFIER ::= { print-engine 10 }
consumables-1 OBJECT IDENTIFIER ::= { consumables 1 }
consumable-status OBJECT IDENTIFIER ::= { consumables-1 1 }
consumables-status OBJECT IDENTIFIER ::= { consumables 5 }
consumables-life OBJECT IDENTIFIER ::= { consumables-status 1 }
consumables-test OBJECT IDENTIFIER ::= { consumables 6 }
settings-scanner OBJECT IDENTIFIER ::= { scanner 1 }
scan-calibration OBJECT IDENTIFIER ::= { settings-scanner 32 }
pe-test-scanner-configuration OBJECT IDENTIFIER ::= { print-engine-test 58 }
printmib OBJECT IDENTIFIER ::= { dm 2 }
prtGeneral OBJECT IDENTIFIER ::= { printmib 5 }
prtGeneralTable OBJECT IDENTIFIER ::= { prtGeneral 1 }
prtGeneralEntry OBJECT IDENTIFIER ::= { prtGeneralTable 1 }
prtCover OBJECT IDENTIFIER ::= { printmib 6 }
prtCoverTable OBJECT IDENTIFIER ::= { prtCover 1 }
prtCoverEntry OBJECT IDENTIFIER ::= { prtCoverTable 1 }
prtLocalization OBJECT IDENTIFIER ::= { printmib 7 }
prtLocalizationTable OBJECT IDENTIFIER ::= { prtLocalization 1 }
prtLocalizationEntry OBJECT IDENTIFIER ::= { prtLocalizationTable 1 }
prtStorageRefTable OBJECT IDENTIFIER ::= { prtGeneral 2 }
prtStorageRefEntry OBJECT IDENTIFIER ::= { prtStorageRefTable 1 }
prtDeviceRefTable OBJECT IDENTIFIER ::= { prtGeneral 3 }
prtDeviceRefEntry OBJECT IDENTIFIER ::= { prtDeviceRefTable 1 }
prtInput OBJECT IDENTIFIER ::= { printmib 8 }
prtInputTable OBJECT IDENTIFIER ::= { prtInput 2 }
prtInputEntry OBJECT IDENTIFIER ::= { prtInputTable 1 }
prtOutput OBJECT IDENTIFIER ::= { printmib 9 }
prtOutputTable OBJECT IDENTIFIER ::= { prtOutput 2 }
prtOutputEntry OBJECT IDENTIFIER ::= { prtOutputTable 1 }
prtMarker OBJECT IDENTIFIER ::= { printmib 10 }
prtMarkerTable OBJECT IDENTIFIER ::= { prtMarker 2 }
prtMarkerEntry OBJECT IDENTIFIER ::= { prtMarkerTable 1 }
prtMarkerSupplies OBJECT IDENTIFIER ::= { printmib 11 }
prtMarkerSuppliesTable OBJECT IDENTIFIER ::= { prtMarkerSupplies 1 }
prtMarkerSuppliesEntry OBJECT IDENTIFIER ::= { prtMarkerSuppliesTable 1 }
prtMarkerColorant OBJECT IDENTIFIER ::= { printmib 12 }
prtMarkerColorantTable OBJECT IDENTIFIER ::= { prtMarkerColorant 1 }
prtMarkerColorantEntry OBJECT IDENTIFIER ::= { prtMarkerColorantTable 1 }
prtMediaPath OBJECT IDENTIFIER ::= { printmib 13 }
prtMediaPathTable OBJECT IDENTIFIER ::= { prtMediaPath 4 }
prtMediaPathEntry OBJECT IDENTIFIER ::= { prtMediaPathTable 1 }
prtInterpreter OBJECT IDENTIFIER ::= { printmib 15 }
prtInterpreterTable OBJECT IDENTIFIER ::= { prtInterpreter 1 }
prtInterpreterEntry OBJECT IDENTIFIER ::= { prtInterpreterTable 1 }
prtConsoleDisplayBuffer OBJECT IDENTIFIER ::= { printmib 16 }
prtConsoleDisplayBufferTable OBJECT IDENTIFIER ::= { prtConsoleDisplayBuffer 5 }
prtConsoleDisplayBufferEntry OBJECT IDENTIFIER ::= { prtConsoleDisplayBufferTable 1 }
prtConsoleLights OBJECT IDENTIFIER ::= { printmib 17 }
prtConsoleLightTable OBJECT IDENTIFIER ::= { prtConsoleLights 6 }
prtConsoleLightEntry OBJECT IDENTIFIER ::= { prtConsoleLightTable 1 }
copier-token OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
ACCESS read-write
STATUS optional
DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate
exclusive access to a copier device. Setting the object to a
unique id will only succeed if the token is currently set to 0.
The token is unlocked when it is set to 0. If the token is set
to any value other than 0, then token is locked. If the token
was set to a unique id (locked), then an attempt to set (lock)
the token will fail. If the token was set to 0 (unlocked), then
an attempt to set (lock) the token will succeed in locking the
token. A get operation on COPIER-TOKEN will return its current
setting. The device does not prevent access to any objects. It
is assumed that hosts will be well behaved; respecting this
advisory locking mechanism by:
1) acquiring the lock before changing copier objects, and
2) releasing the lock when done changing copier objects.
Additional information:
Provides an advisory locking mechanism for hosts to
coordinate exclusive access. Setting the object to a unique id
will only succeed if the token is currently set to 0. The token
is unlocked when it is set to 0. If the token is set to a any
value other than 0, then token is locked.
If the token was set to a unique id (locked), then an
attempt to set (lock) the token will fail.
If the token was set to 0 (unlocked), then an attempt to set (lock)
the token will succeed in locking the token.
A get operation on COPY-TOKEN will return its current setting.
The device does not prevent access to any objects. It is assumed
that hosts will be well behaved; respecting this advisory locking
mechanism by:
1) acquiring the lock before changing copy objects, and
2) releasing the lock when done changing copy objects."
::= { settings-system 24 }
copy-scanner-dimensions OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "This object is used to obtain the exact pixel scan dimensions
for copy. The dimensions returned correspond to the quality,
reduce/enlarge, and media size currently selected.
Additional information:
This object is used to obtain the exact pixel scan dimensions for copy.
The dimensions returned correspond to the quality, reduce/enlarge,
and media size currently selected."
::= { status-scanner 13 }
copier-contrast OBJECT-TYPE
SYNTAX INTEGER(-127..127)
ACCESS read-write
STATUS optional
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
used for setting the copier contrast level. Range is 0..100.
Additional information:
Behaves as SCL's 'Set Scanner Contrast Level' command
which is used for setting the copier contrast level. Contrast
values can range from -127 to +127, for a total of 255 contrast
levels. A positive value results in a larger difference, and a
negative value results in a smaller difference. We support the
values -125, -100, -75, -50, -25, 0, 25, 50, 75, 100, 125.
We will map by snapping toward 0, to the closest device dependent
value if some other value is given. "
::= { settings-copier 2 }
copier-reduction OBJECT-TYPE
SYNTAX INTEGER(25..400)
ACCESS read-write
STATUS optional
DESCRIPTION "Percentage reduction desired for the copier. A value less than
or equal to zero is invalid. A value greater than 100
accomplishes magnification. A device is allowed to support a
set of values (documented in its POS), instead of the full
range. <OKNearestLegalValue Used> will be returned for unsupported values greater than zero.
Additional information:
Percentage reduction desired for the copier. A value less
than or equal to zero is invalid. A value greater than 100
accomplishes magnification. A device is allowed to support a set
of values (documented in its POS), instead of the full range.
<OKNearestLegalValueUsed> will be returned for unsupported valuesgreater than zero.
Our default of 100 means no scaling"
::= { settings-copier 4 }
copier-num-copies OBJECT-TYPE
SYNTAX INTEGER(1..99)
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the number of copies to be printed in the
next Host requested copy operation.
Additional information:
Returns or changes the number of copies to be printed in
the next Host requested copy operation."
::= { settings-copier 6 }
copier-collation OBJECT-TYPE
SYNTAX INTEGER {
eCollateDisabled(1),
eCollateForward(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Enables the device with local copier capability that also
supports outputting multiple copies of a multi-paged source
document to print in a collated fashion.
eCollateDisabled - The collating feature of the copier
device is not to be performed on subsequent copier
operation.
eCollateForward - Copier device is to print multiple copies
of the input document in such a way that the printed
output order matches the source document.
eCollateReverse - Copier device is to print multiple copies
of the input document such that the order of the
printed output is in reverse order of the source
document.
Additional information:
Enables the device with local copier capability that
also supports outputting multiple copies of a multi-
paged source document to print in a collated fashion.
eCollateDisabled - The collating feature of the copier
device is not to be performed on subsequent copier
operation.
eCollateForward - Copier device is to print multiple
copies of the input document in such a way that the
printed output order matches the source document."
::= { settings-copier 7 }
copier-enlargement-maximum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Maximum value that the host may set COPIER-REDUCTION to. A
value less than or equal to zero is invalid.
Additional information:
Maximum value that the host may set COPIER-REDUCTION or
COPIER-JOB-REDUCTION to.
A value less than or equal to zero is invalid."
::= { settings-copier 11 }
copier-reduction-maximum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Minimum value that the host may set COPIER-REDUCTION to. A
value less than or equal to zero is invalid.
Additional information:
Minimum value that the host may set COPIER-REDUCTION or
COPIER-JOB-REDUCTION to.
A value less than or equal to zero is invalid."
::= { settings-copier 12 }
copier-quality OBJECT-TYPE
SYNTAX INTEGER {
eCopierQualityFast(1),
eCopierQualityNormal(2),
eCopierQualityPresentation(3),
eCopierQualityPicture(6),
eCopierQualityAutoSelect(7)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the copier quality. This value is stored in
NVRAM, hence the value is saved over power cycles.
Additional information:
This value is stored in NVRAM, hence the value is
saved over power cycles.
eCopierQualityFast is mapped to eCopierQualityNormal."
::= { settings-copier 13 }
copier-adf-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages scanned for
copying through the ADF. In order to write this object
SERVICE-PASSWORD must be set correctly.
Additional information:
This object tracks the page count for pages
scanned for copying through the ADF. This value is
stored in the device NVRAM."
::= { settings-copier 19 }
copier-print-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages sent to the
print engine, for copy jobs. In order to write this object
SERVICE-PASSWORD must be set correctly.
Additional information:
This object tracks the page count for pages sent to
the print engine, for monochrome copy jobs. This value is
stored in the device NVRAM."
::= { settings-copier 20 }
copier-job-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSLetter(2),
eUSLegal(3),
eISOandJISA4(26)
}
ACCESS read-write
STATUS optional
DESCRIPTION "The user can set a copy job setting for paper size using the
COPIER-JOB-MEDIA-SIZE object, which is independent of other
functions in the device. The device behavior when the scanned
media and or print media do not match the value of this object
should be documented in the device POS. (for a full list of
media size enums see the end of this file)
Additional information:
The default size for imaging a copy is
determined by reading the common device default paper size
object. The default for copy size cannot be changed
independently of other functions like fax and print. The
device will scan and format the print data based on the value
of this object."
::= { settings-copier 21 }
copier-job-quality OBJECT-TYPE
SYNTAX INTEGER {
eCopierQualityFast(1),
eCopierQualityNormal(2),
eCopierQualityPresentation(3),
eCopierQualityPicture(6),
eCopierQualityAutoSelect(7)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the copier quality.
Additional information:
Returns or sets the copier quality.
eCopierQualityFast is supported but gets mapped to normal."
::= { settings-copier 22 }
copier-job-collation OBJECT-TYPE
SYNTAX INTEGER {
eCollateDisabled(1),
eCollateForward(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Enables the device with local copier capability that also
supports outputting multiple copies of a multi-paged source
document to print in a collated fashion. eCollateDisabled - The
collating feature of the copier device is not be performed on
subsequent copier operation. eCollateForward - Copier device is
to print multiple copies of the input document in such a way
that the printed output order matches the source document.
eCollateReverse - Copier device is to print multiple copies of
the input document such that the order of the printed output is
in reverse order of the source document. "
::= { settings-copier 23 }
copier-job-num-copies OBJECT-TYPE
SYNTAX INTEGER(1..99)
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the number of copies to be printed in the
next Host requested copy operation."
::= { settings-copier 24 }
copier-job-reduction OBJECT-TYPE
SYNTAX INTEGER(25..400)
ACCESS read-write
STATUS optional
DESCRIPTION "Percentage reduction desired for the copier. A device is
allowed to support a set of values (documented in its POS),
instead of the full range. <OKNearesetLegalValueUsed> will be
returned for unsupported values.
Additional information:
A value less than or equal to zero is invalid.
A value greater than 100 accomplishes magnification.
<OKNearestLegalValueUsed> will be returned for unsupported valuesgreater than zero.
(default = 100 = no scaling)."
::= { settings-copier 25 }
copier-job-contrast OBJECT-TYPE
SYNTAX INTEGER(-127..127)
ACCESS read-write
STATUS optional
DESCRIPTION "Used to set the copier contrast level.
Additional information:
Behaves as SCL's 'Set Scanner Contrast Level' command
which is used for setting the copier contrast level. Contrast values
can range from <20>-127 to +127, for a total of 255 contrast levels.
The default contrast level is 0 (normal). A positive value results
in a larger difference, and a negative value results in a smaller
difference.
We support values of -125, -100, -75, -50, -25, 0, 25, 50, 75,
100, 125. The range of values we support is spread over a
range such that a software product would support the standard spec,
and we would map by snapping toward 0 to the closest device dependent
value."
::= { settings-copier 26 }
copier-job OBJECT-TYPE
SYNTAX INTEGER {
eCopierIdle(1),
eCopierStart(2),
eCopierActive(3),
eCopierAborting(4),
eCopierSetup(5)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Controls initiating and canceling a copy job.
Additional information:
Controls initiating and canceling a copy job.
eCopierIdle <20> indicates that a copy function is not in progress.
- Device sets to this state from eCopierActive to signal successful
completion of copy operation.
- Device sets to this state from eCopierAborting to signal successful
cancel of copy operation.
- Device sets to this state from eCopierStart to signal that the device is
busy and cannot perform a copy operation.
- Host sets to this state to indicate it wants to cancel the job. Device
will abort the job.
eCopierSetup <20> indicates the host wants to set up job settings for a copy
job. Host sets to this state to then access copier job settings objects.
Device does not set to this state. Object can only transition to this state
from eCopierIdle.
eCopierStart - This state is set by host to request copy function initiation.
Object can only transition to this state from eCopierSetup.
To specify job settings host has to set to Setup first,
send settings, then set to Start. Device should not set to this state.
eCopierActive <20> indicates the copy function is in progress. Device sets this
state if the activity was started through front panel or if host request was
successfully initiated. Host should not set to this state.
eCopierAborting <20> Set by device to indicate copy function was prematurely
terminated, either by an error, or user canceled by pressing cancel button
on device. Device stays in this state until abort is complete, then moves to
eCopierIdle. Host cannot set to this state, host sets to eCopierIdle to indicate
it want to cancel the job.
- Device powers up in eCopierIdle. "
::= { settings-copier 27 }
default-copy-duplex-mode OBJECT-TYPE
SYNTAX INTEGER {
eSimplexToSimplex(1),
eSimplexToDuplexLongEdgeBinding(2),
eDuplexToDuplex(4),
eDuplexToSimplexLongEdgeBinding(5)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the duplex copying mode. Duplex printing is
when printing occurs on both sides of a sheet of media. Long
edge binding is also called vertical binding or book binding.
Short edge binding is also called horizontal binding or
calendar binding.
eSimplexToSimplex: takes image data from only one side of
the original document, and print only on one side of
each copy.
eSimplexToDuplexLongEdgeBinding: takes image data from only
one side of the original document, and print to both
sides of each copy. The images are rotated so that if
the media is rotated along the axis of the long edge of
the media, both images would appear as in the original.
eSimplexToDuplexShortEdgeBinding: takes image data from
only one side of the original document, and print to
both sides of each copy. The images are rotated so that
if the media is rotated along the axis of the short
edge of the media, both images would appear as in the
original.
eDuplexToDuplex: takes image data from both sides of the
original document, and print on both sides of each
copy.
eDuplexToSimplexLongEdgeBinding: takes image data from both
sides of the original document, and prints to only one
side of each copy. The images are rotated so that if
the media is rotated along the axis of the long edge of
the media, both images would appear as in the original.
eDuplexToSimplexShortEdgeBinding: takes image data from
both sides of the original document, and prints to only
one side of each copy. The images are rotated so that
if the media is rotated along the axis of the short
edge of the media, both images would appear as in the
original.
Additional information:
Returns or sets the duplex copying mode. Duplex printing is
when printing occurs on both sides of a sheet of media. Long
edge binding is also called vertical binding or book binding.
Short edge binding is also called horizontal binding or
calendar binding.
eSimplexToSimplex: takes image data from only one side of
the original document, and print only on one side of
each copy.
eSimplexToDuplexLongEdgeBinding: takes image data from only
one side of the original document, and print to both
sides of each copy. The images are rotated so that if
the media is rotated along the axis of the long edge of
the media, both images would appear as in the original.
eSimplexToDuplexShortEdgeBinding: takes image data from
only one side of the original document, and print to
both sides of each copy. The images are rotated so that
if the media is rotated along the axis of the short
edge of the media, both images would appear as in the
original.
eDuplexToDuplex: takes image data from both sides of the
original document, and print on both sides of each
copy.
eDuplexToSimplexLongEdgeBinding: takes image data from both
sides of the original document, and prints to only one
side of each copy. The images are rotated so that if
the media is rotated along the axis of the long edge of
the media, both images would appear as in the original.
eDuplexToSimplexShortEdgeBinding: takes image data from
both sides of the original document, and prints to only
one side of each copy. The images are rotated so that
if the media is rotated along the axis of the short
edge of the media, both images would appear as in the
original.
If duplex print has been disabled the object will return an error
for pmlsets on eSimplexToDuplexLongEdgeBinding(2) and
eDuplexToDuplex(4). If duplex scan has been disabled it will
return an error for pmlsets on eDuplexToDuplex(4) and
eDuplexToSimplexLongEdgeBinding(5).If the device has both disabled
or the features is are present, such as on a kiwi, both pmlsets and
pmlgets will return an error for all enumerations."
::= { settings-copier 28 }
copier-flatbed-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages scanned for
copying from the flatbed. In order to write this object
SERVICE-PASSWORD must be set correctly.
Additional information:
This object tracks the page count for pages
scanned for copying from the flatbed. This value is
stored in the device NVRAM."
::= { settings-copier 44 }
copier-pages-per-sheet OBJECT-TYPE
SYNTAX INTEGER {
ePagesPerSheet1(1)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the copier number of input pages per output
sheet. This is also known as nup. This value is stored in
NVRAM, hence the value is saved over power cycles.
Additional information:
Enables the device with local copier capability that
also supports outputting multiple copies of a multi-
paged source document to print multiple input sheets onto
a single output sheet.
ePagesPerSheet_1: A single input image is placed on a
single output sheet. This basically has no affect.
ePagesPerSheet_2: Two input images are placed on a
single output sheet, in landscape format.
ePagesPerSheet_4: Four input images are placed on
a single output sheet, in portrait format.
NOTE: The Pages Per Sheet feature will only be supported
on devices with an ADF. If no ADF is present, then
changes to this object will not be allowed."
::= { settings-copier 45 }
copier-job-pages-per-sheet OBJECT-TYPE
SYNTAX INTEGER {
ePagesPerSheet1(1),
ePagesPerSheet2(2),
ePagesPerSheet4(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the copy value for how many input pages per
output sheet.
Additional information:
Enables the device with local copier capability that
also supports outputting multiple copies of a multi-
paged source document to print multiple input sheets onto
a single output sheet.
ePagesPerSheet1: A single input image is placed on a
single output sheet. This basically has no affect.
ePagesPerSheet2: Two input images are placed on a
single output sheet, in landscape format.
ePagesPerSheet4: Four input images are placed on
a single output sheet, in portrait format.
NOTE: The Pages Per Sheet feature will only be supported
on devices with an ADF. If no ADF is present, then
changes to this object will not be allowed."
::= { settings-copier 46 }
copier-fit-to-page OBJECT-TYPE
SYNTAX INTEGER {
eFitToPageDisabled(1)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the copy setting for fit to page. This value is
stored in NVRAM; hence, the value is saved over power cycles.
Additional information:
Enables the device with local copier capability to
fit the input image size automatically onto the output sheet
size."
::= { settings-copier 47 }
copier-job-fit-to-page OBJECT-TYPE
SYNTAX INTEGER {
eFitToPageDisabled(1)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the copy value for fit to page.
Additional information:
Enables the device with local copier capability to
fit the input image size automatically onto the output sheet
size."
::= { settings-copier 48 }
copier-pages-per-sheet-maximum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Maximum pages per sheet value supported by the COPIER-
PAGES-PER-SHEET and COPIER-JOB-PAGES-PER-SHEET objects. A value
less than or equal to zero is invalid.
Additional information:
Maximum value supported for COPIER-PAGES-PER-SHEET or
COPIER-JOB-PAGES-PER-SHEET objects.
A value less than or equal to zero is invalid."
::= { settings-copier 49 }
copier-adf-test-mode OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This is only writable in service mode. When this object is
enabled, all copy jobs following will only scan the pages and
throw the data away rather than printing. This is used for
testing the ADF. When this is disabled, the device will copy as
normal.
Additional information:
This is only writable in service mode. When this
object is set to enabled, all copy jobs following will only
scan the pages and throw the data away rather than printing.
This is used for testing the ADF. When this is set back to
disabled, then the device will copy as normal."
::= { settings-copier 65 }
copier-adf-test-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Reads the number of pages printed during the last ADF copy
test. This object is associated with the COPIER-ADF-TEST-MODE
object.
Additional information:
Reads the number of pages printed during the last
ADF copy test. This is associated with the COPIER-ADF-TEST-MODE
object."
::= { settings-copier 66 }
copier-job-draft-mode OBJECT-TYPE
SYNTAX INTEGER {
eOn(1),
eOff(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Enables the device with local copier capability to turn on a
draft printing mode.
Additional information:
Enables the device with local copier capability to turn on a
draft printing mode."
::= { settings-copier 86 }
copier-draft-mode OBJECT-TYPE
SYNTAX INTEGER {
eOn(1),
eOff(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Enables the device with local copier capability to turn on a
draft printing mode.
Additional information:
Enables the device with local copier capability to turn on a
draft printing mode."
::= { settings-copier 87 }
copier-job-multipage OBJECT-TYPE
SYNTAX INTEGER {
eOn(1),
eOff(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Enables the device with local copier capability to turn on
multi page copying from the flatbed.
Additional information:
Enables the device with local copier capability to turn on
multi page copying from the flatbed."
::= { settings-copier 88 }
copier-multipage OBJECT-TYPE
SYNTAX INTEGER {
eOn(1),
eOff(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Enables the device with local copier capability to turn on
multi page copying from the flatbed.
Additional information:
Enables the device with local copier capability to turn on
multi page copying from the flatbed."
::= { settings-copier 89 }
device-cfg-download OBJECT-TYPE
SYNTAX INTEGER {
eCfgDownloadIdle(1),
eCfgDownloadStart(2),
eCfgDownloadActive(3),
eCfgDownloadAborted(4),
eCfgDownloadDone(5)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Handshaking mechanism between host and device to coordinate the
download of device specific data.
eCfgDownloadIdle - indicates device configuration download
activity is not occurring. Device powers up in this
state but will otherwise never transition to this
state. This state is host settable from
eCfgDownloadActive, eCfgDownloadDone, and
eCfgDownloadAborted. Host setting to eCfgDownloadIdle
while object is in eCfgDownloadActive will cause the
download activity to be prematurely terminated. Host
setting to this state resets the object to permit
another download activity to be initiated.
eCfgDownloadStart - indicates host wishes to commence a
device configuration download activity. This state is
only host settable from eCfgDownloadIdle. Only the
device can transition this object from this state to
eCfgDownloadActive or eCfgDownloadAborted. Device will
not set to this state.
eCfgDownloadActive - indicates download activity is in
progress. Device transitions object to this state only
from eCfgDownloadStart, to signal data download can
commence. The device can transition from this state to
eCfgDownloadDone or eCfgDownloadAborted. The host can
transition from this state to eCfgDownloadIdle. This
state is not host settable.
eCfgDownloadAborted - indicates the download activity was
terminated by the device. Only the device can set to
this state from eCfgDownloadStart or
eCfgDownloadActive. Only the host can transition from
this state to eCfgDownloadIdle. This state is not host
settable.
eCfgDownloadDone - indicates device has completely received
the download data. Device transitions to this state
only from eCfgDownloadActive. Only the host can
transition from this state to eCfgDownloadIdle. This
state is not host settable. "
::= { settings-system 11 }
device-cfg-download-data-type OBJECT-TYPE
SYNTAX INTEGER {
eSpeedDials(5),
eFaxLogs(6),
eConfigPrams(7),
eJunkFaxDialStrings(9)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates the type of device specific data to be downloaded."
::= { settings-system 12 }
device-cfg-upload OBJECT-TYPE
SYNTAX INTEGER {
eCfgUploadIdle(1),
eCfgUploadStart(2),
eCfgUploadActive(3),
eCfgUploadAborted(4),
eCfgUploadDone(5)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Handshaking mechanism between host and device to coordinate the
upload of device specific data.
eCfgUploadIdle - indicates device configuration upload
activity is not occurring. Device powers up in this
state but will otherwise never transition to this
state. This state is host settable from
eCfgUploadActive, eCfgUploadDone, and
eCfgUploadAborted. Host setting to eCfgUploadIdle while
object is in eCfgUploadActive will cause the upload
activity to be prematurely terminated. Host setting to
this state resets the object allowing a new upload to
be initiated.
eCfgUploadStart - indicates host wishes to commence a
device configuration upload activity. This state is
only host settable from eCfgUploadIdle. Only the device
can transition this object from this state to
eCfgUploadActive or eCfgUploadAborted. Device will not
set to this state.
eCfgUploadActive - indicates upload activity is in
progress. Device transitions object to this state only
from eCfgUploadStart, to signal data upload can
commence. The device can transition from this state to
eCfgUploadDone or eCfgUploadAborted. The host can
transition from this state to eCfgUploadIdle. This
state is not host settable.
eCfgUploadAborted - indicates the upload activity was
terminated by the device. Only the device can set to
this state from eCfgUploadStart or eCfgUploadActive.
Only the host can transition from this state to
eCfgUploadIdle. This state is not host settable.
eCfgUploadDone - indicates device completely transmitted
the upload data. Device transitions to this state only
from eCfgUploadActive. Only the host can transition
from this state to eCfgUploadIdle. This state is not
host settable. "
::= { settings-system 13 }
device-cfg-upload-data-type OBJECT-TYPE
SYNTAX INTEGER {
eSpeedDials(5),
eFaxLogs(6),
eConfigPrams(7),
eJunkFaxDialStrings(9)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates the type of device specific data to be uploaded."
::= { settings-system 14 }
download-timeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Specifies the number of seconds that device will wait for data
from the host before the device determines the host is being
unresponsive. This timeout condition may cause the device to
take recourse action regarding the disposition of the download
activity. A value of zero indicates device will wait forever
for the host data. POS should indicate whether this object
value, when set by the host, is remembered between device power
cycles.
Additional information:
This object is volatile and as such will not be
retained by the device between power cycles."
::= { settings-system 17 }
upload-timeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Specifies the number of seconds that device will wait for
response from the host after transmitting a unit of data before
the device determines the host is being unresponsive. This
timeout condition may cause the device to take recourse action
regarding the disposition of the upload activity. A value of
zero indicates device will wait forever for the host response.
POS should indicate whether this object value, when set by the
host, is remembered between device power cycles.
Additional information:
This object is volatile and as such will not be
retained by the device between power cycles."
::= { settings-system 18 }
date-display OBJECT-TYPE
SYNTAX INTEGER {
eDateDisplayMMDDYY(1),
eDateDisplayDDMMYY(2),
eDateDisplayYYMMDD(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Controls front-panel date display format.
Additional information:
Controls front-panel date display format."
::= { settings-system 22 }
device-cfg-param-command OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "A C structure containing the following fields: typedef
struct {
u8bit list_id;
s8bit auto_incr;
u16bit max_index;
u16bit rec_size;
u16bit index;
u8bit data[];
} PML_device_cfg_param_cmd_t;
where u8bit is an unsigned byte (0..255), s8bit is a signed
byte (-128..127), and u16bit is a big endian format unsigned
short (0..65535). The POS should state which list_id's the
device supports.
Additional information:
This LaserJet MFP supports two values for list_id:
0 for configuration parameters and
1 for default configuration parameters."
::= { settings-system 23 }
fax-upload-token OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
ACCESS read-write
STATUS optional
DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate
exclusive access to the fax upload features of a device.
Setting the object to a unique id will only succeed if the
token is currently set to 0. The token is unlocked when it is
set to 0. If the token is set to any value other than 0, then
token is locked. If the token was set to a unique id (locked),
then an attempt to set (lock) the token will fail. If the token
was set to 0 (unlocked), then an attempt to set (lock) the
token will succeed in locking the token. A get operation on
FAX-UPLOAD-TOKEN will return its current setting. The device
does not prevent access to any objects. It is assumed that
hosts will be well behaved; respecting this advisory locking
mechanism by:
1) acquiring the lock before changing any fax-upload
objects, and
2) releasing the lock when done changing scan objects.
Additional information:
Provides an advisory locking mechanism for hosts to
coordinate exclusive access. Setting the object to a unique id
will only succeed if the token is currently set to 0. The token
is unlocked when it is set to 0. If the token is set to a any
value other than 0, then token is locked.
If the token was set to a unique id (locked), then an
attempt to set (lock) the token will fail.
If the token was set to 0 (unlocked), then an attempt to set (lock)
the token will succeed in locking the token.
A get operation on FAX-UPLOAD-TOKEN will return its current setting.
The device does not prevent access to any objects. It is assumed
that hosts will be well behaved; respecting this advisory locking
mechanism by:
1) acquiring the lock before changing fax objects, and
2) releasing the lock when done changing fax objects."
::= { settings-system 26 }
fax-download-token OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..128))
ACCESS read-write
STATUS optional
DESCRIPTION "Provides an advisory locking mechanism for hosts to coordinate
exclusive access to the fax download features of a device.
Setting the object to a unique id will only succeed if the
token is currently set to 0. The token is unlocked when it is
set to 0. If the token is set to any value other than 0, then
token is locked. If the token was set to a unique id (locked),
then an attempt to set (lock) the token will fail. If the token
was set to 0 (unlocked), then an attempt to set (lock) the
token will succeed in locking the token. A get operation on
FAX-DOWNLOAD-TOKEN will return its current setting. The device
does not prevent access to any objects. It is assumed that
hosts will be well behaved; respecting this advisory locking
mechanism by:
1) acquiring the lock before changing any fax-download
objects, and
2) releasing the lock when done changing scan objects.
Additional information:
Provides an advisory locking mechanism for hosts to
coordinate exclusive access. Setting the object to a unique id
will only succeed if the token is currently set to 0. The token
is unlocked when it is set to 0. If the token is set to a any
value other than 0, then token is locked.
If the token was set to a unique id (locked), then an
attempt to set (lock) the token will fail.
If the token was set to 0 (unlocked), then an attempt to set (lock)
the token will succeed in locking the token.
A get operation on FAX-DOWNLOAD-TOKEN will return its current setting.
The device does not prevent access to any objects. It is assumed
that hosts will be well behaved; respecting this advisory locking
mechanism by:
1) acquiring the lock before changing fax objects, and
2) releasing the lock when done changing fax objects."
::= { settings-system 27 }
date-and-time OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "A C structure containing the following fields: typedef
struct {
ubyte yr; /* year: 0 to 99 */
ubyte mon; /* month: 1 to 12 */
ubyte day; /* day: 1 to 31 */
ubyte wday; /* Day of week: 1 to 07 */
ubyte hr; /* hour: 0 to 23 */
ubyte min; /* minute: 0 to 59 */
ubyte sec; /* second: 0 to 59 */
} date_t;
where ubyte is an unsigned byte (0-255)."
::= { status-system 17 }
time-display OBJECT-TYPE
SYNTAX INTEGER {
eTimeDisplayTwelveHour(1),
eTimeDisplayTwentyFourHour(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Controls front-panel time display format. Set to
eTimeDisplayTwelveHour for AM/PM display. Set to
eTimeDisplayTwentyFourHour for military-type display."
::= { status-system 28 }
device-cfg-download-error OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Error status of the configuration download session. POS should
indicate the actual error values reserving value 0 as NO
ERROR.
Additional information:
A value of 0 indicates NO ERROR."
::= { status-system 43 }
device-cfg-upload-error OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Error status of the configuration upload session. POS should
indicate the actual error values reserving value 0 as NO
ERROR.
Additional information:
A value of 0 indicates NO ERROR."
::= { status-system 45 }
fax-local-phone-num OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "CCITT sender's station id (ex. 08-396-4122)."
::= { id 8 }
fax-station-name OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "name for the fax device (ex. HP R&D)."
::= { id 9 }
fax-line-interface-unit-id OBJECT-TYPE
SYNTAX INTEGER(0..8)
ACCESS read-only
STATUS optional
DESCRIPTION "The fax device line interface unit (LIU) identifier. The LIU
number identifies the telephone system electrical
characteristics supported by this device.
Additional information:
In this LaserJet MFP this value is stored in 3 bits on the
LIU."
::= { id 18 }
faxjob-action OBJECT-TYPE
SYNTAX INTEGER {
ePrintFaxToPrinter(1),
eDeleteFaxFromMemory(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Permits host to specify an action to be applied with a
particular fax."
::= { settings-fax-job 1 }
faxjob-action-id OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Contains the fax job identification of the fax to be acted upon
by the action specified by the object FAXJOB-ACTION."
::= { settings-fax-job 2 }
faxjob-tx-type OBJECT-TYPE
SYNTAX INTEGER {
eSrcHostOnly(2),
eSrcScannerOnly(5),
eSrcHostToMemoryOnly(9)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates sources of the fax image for transmission. Also
specifies the temporal order of the data sources.
eSrcHostOnly - The fax document images will be wholly
downloaded from the host.
eSrcScannerOnly - The fax document images originate wholly
from the device scanner/ADF subsystem.
eSrcHostThenScanner - The fax document is composed of
images downloaded from the host and pages from the
scanner/ADF subsystem. The host downloaded pages will
be faxed first, followed by the pages in the
scanner/ADF.
eSrcScannerThenHost - The fax document is composed of pages
in the scanner/ADF and the images downloaded from the
host. The document in the ADF is faxed first, followed
by the pages downloaded from the host.
eSrcHostThenMemory - The fax document is composed of pages
downloaded from the host and images already stored
within the device. The fax transmission will contain
the host downloaded pages followed by the images in the
device memory.
eSrcHostToMemoryOnly - Permits fax images to be downloaded
into device memory for later use with
eSrcHostThenMemory.
Additional information:
eSrcHostToMemoryOnly is included for
development and testing only. eSrcHostToMemoryOnly will
not be an allowed value for this object in the released
product."
::= { settings-fax-job 3 }
faxjob-print-duplex-mode-select OBJECT-TYPE
SYNTAX INTEGER {
eDuplexerDisabled(1),
eDuplexerEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Allows the host to enable or disable duplex printing on a
device for the next fax job.
Additional information:
Allows the host to enable or disable duplex printing on a
device for the next fax job."
::= { settings-fax-job 5 }
faxjob-download-id OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains the device assigned job identification for the current
fax downloading job. The job ID is monotonically increasing
number. The job ID may be reset to zero or may roll over to
zero after reaching some maximum. The maximum value before the
rollover should be stated in the POS.
Additional information:
The maximum value before this object rolls over
to 0 is 2,147,483,648. Behavior of this object once
the value rolls over to 0 is not specified."
::= { status-fax-job 1 }
faxjob-rx-id OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains the device assigned job identification for the
currently fax reception job. The job ID is monotonically
increasing number. The job ID may be reset to zero or may roll
over to zero after reaching some maximum. The maximum value
before the rollover should be stated in the POS.
Additional information:
The maximum value before this object rolls over
to 0 is 2,147,483,648. Behavior of this object once
the value rolls over to 0 is not specified."
::= { status-fax-job 2 }
faxjob-tx-id OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains the device assigned job identification for the current
fax transmission job. The job ID is monotonically increasing
number. The job ID may be reset to zero or may roll over to
zero after reaching some maximum. The maximum value before the
rollover should be stated in the POS.
Additional information:
The maximum value before this object rolls over
to 0 is 2,147,483,648. Behavior of this object once
the value rolls over to 0 is not specified."
::= { status-fax-job 3 }
faxjob-upload-id OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains the device assigned job identification for the current
fax upload job. The job ID is monotonically increasing number.
The job ID may be reset to zero or may roll over to zero after
reaching some maximum. The maximum value before the rollover
should be stated in the POS.
Additional information:
The maximum value before this object rolls over
to 0 is 2,147,483,648. Behavior of this object once
the value rolls over to 0 is not specified."
::= { status-fax-job 4 }
faxjob-rx-status-1 OBJECT-TYPE
SYNTAX INTEGER {
eFaxRxIdle(1),
eFaxRxRinging(2),
eFaxRxAnswering(3),
eFaxRxReceiving(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Status of receiving fax session 1."
::= { faxjob-rx-status 1 }
faxjob-tx-status-1 OBJECT-TYPE
SYNTAX INTEGER {
eFaxTxIdle(1),
eFaxTxDialing(2),
eFaxTxConnecting(3),
eFaxTxTransmitting(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Status of sending fax session 1."
::= { faxjob-tx-status 1 }
faxjob-tx-error-1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Error status of the fax reception session 1.
Additional information:
Error status of the fax transmission session 1."
::= { faxjob-tx-error 1 }
faxjob-tx-current-page-1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The page number of the fax page currently being transmitted via
send fax session 1. Starts with page number 1."
::= { faxjob-tx-current-page 1 }
faxjob-rx-current-page-1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The page number of the fax page currently being received via
fax reception session 1. Starts with page number 1."
::= { faxjob-rx-current-page 1 }
faxjob-rx-duration-1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Represent the number of seconds of phone-connect time for a fax
reception session 1."
::= { faxjob-rx-duration 1 }
faxjob-tx-duration-1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Represent the number of seconds of phone-connect time for send
fax session 1."
::= { faxjob-tx-duration 1 }
fax-log-action OBJECT-TYPE
SYNTAX INTEGER {
eIdle(1),
eClear(2),
ePrintLatest(3),
ePrintAll(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Provides applications with the ability to clear or print the
fax transaction log. eIdle - no action is occurring on the fax
log. eClear - clear the fax log. ePrintLatest - print the
latest entry in the fax log. ePrintAll - print all the entries
in the fax log. When this object is set to a non-eIdle value by
an application, the given action starts. When the action is
complete, this object is changed back to eIdle by the device. A
host's request to write this object will be rejected when the
object is not eIdle. When eIdle, the host may set the object to
any value (including eIdle)."
::= { settings-faxlog 1 }
fax-log-reporting OBJECT-TYPE
SYNTAX INTEGER {
eNever(1),
eErrorOnly(2),
eSendOnly(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Specifies when fax transaction logs are to be printed."
::= { settings-faxlog 2 }
fax-dial-mode OBJECT-TYPE
SYNTAX INTEGER {
eToneDial(1),
ePulseDial(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Device should use DTMF dialing if eToneDial, pulse dial if
ePulseDial."
::= { dial-all-lines 1 }
device-redial OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Device to permit redial upon detecting certain error
conditions."
::= { dial-all-lines 2 }
fax-pulse-dial-support OBJECT-TYPE
SYNTAX INTEGER {
eSupported(1),
eNotSupported(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION "This object reports whether the current set country supports
pulse dial.
Additional information:
This object reports whether the current set country supports pulse
dial. In this LaserJet MFP, it checks the DS variable, which is updated
when the pml object FAX-COUNTRY is changed."
::= { dial-all-lines 3 }
fax-answer-mode OBJECT-TYPE
SYNTAX INTEGER {
eManualAnswer(1),
eFaxAnswer(2),
eTadAnswer(3),
eFaxTelAnswer(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Sets the answering-priority when using a shared voice line.
eManualAnswer - Device will not automatically answer the phone.
User must answer and push START button. eFaxAnswer - Device
should assume call is fax, send CED immediately upon answering.
eTadAnswer - (Telephone Answering Device Mode) Device allows
downstream TAD to answer but device will eavesdrop for fax CNG
signal. If a CNG detected, cut off the downstream device, send
CED. Do nothing if CNG not detected."
::= { answer-all-lines 1 }
fax-num-rings-pickup OBJECT-TYPE
SYNTAX INTEGER(1..6)
ACCESS read-write
STATUS optional
DESCRIPTION "Number of rings before the fax device answers the phone if
FAX-ANSWER-MODE is not set to MANUAL-MODE."
::= { answer-all-lines 2 }
device-ring-type-pickup OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Device to answer the incoming call based on detecting the the
specified type of telephone ring."
::= { answer-all-lines 3 }
fax-receive-stamping-enable OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Controls whether or not incoming pages of a fax will be stamped
upon receipt. Content of the stamp is device-specific but may
include such information as date, time, fax station name, and
page number. When this object is set to eEnabled each page of
an incoming fax is stamped by the device. When this object is
set to eDisabled incoming fax pages are not stamped.
Additional information:
When this object is set to eEnabled each page of an
incoming fax is stamped with the date, time, fax station
name, and page number. When this object is set to
eDisabled incoming fax pages are not stamped.
//
The received fax page will be scaled down 0.03% to
accomodate the header. No header will be printed on
page 2 of paginated output."
::= { settings-fax-receive 1 }
not-ready-fax-receive OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates if the receiving fax sub-system in the device is not
ready. If there are no items in the collection (i.e. no bits
are set), then the receiving fax sub-system is ready. If there
is an item present, then the item indicates what is causing the
receiving fax sub-system to be not ready."
::= { status-fax-receive 1 }
fax-rxscale OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Received faxes are to be printed at a reduced scale percentage.
Value of 0 indicates auto-scaled printing based on the length
of the received fax image and the length of the paper."
::= { settings-fax-proc-sub 1 }
fax-noise-volume OBJECT-TYPE
SYNTAX INTEGER(0..200)
ACCESS read-write
STATUS optional
DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest
possible. A device shall divide this value into ranges
corresponding to the possible volumes.
Additional information:
For this LaserJet MFP the range is 0..200, where 0=off (silent),
30=soft, 80=medium, and 180=loud.
For this LaserJet MFP this object refers to the line monitor
noise volume. The decimal values above correspond
to the hex values the object gets set to."
::= { settings-fax-proc-sub 3 }
fax-download OBJECT-TYPE
SYNTAX INTEGER {
eFaxDownloadIdle(1),
eFaxDownloadStart(2),
eFaxDownloadActive(3),
eFaxDownloadAborted(4),
eFaxDownloadDone(5)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Note: Changed enumeration values in a non-backwards manner in
version 4.7. Handshake mechanism between host and device to
initiate and coordinate the download of fax image data to be
transmitted by the device fax modem. This object serves both as
an indicator of fax download activity as well as a trigger for
the host to alter fax download progress. This object has been
redefined to track only the download acpect of the fax
transmission.
eFaxDownloadIdle - indicates no fax download activity is
occurring. Device powers up in this state but will
otherwise never transition to this state of its own
accord. Host setting to eFaxDownloadIdle while object
is in eFaxDownloadActive will cause download activity
to be prematurely terminated. Host setting to this
state resets the handshake mechanism to permit a
another fax download activity to be initiated.
eFaxDownloadStart - indicates the host requests to commence
a download session for sending a fax. This state is
host settable only from eFaxDownloadIdle. Device will
never transition to this state of its own accord.
eFaxDownloadActive - indicates a fax download is occurring.
This state is not host settable. Device will transition
to this state from eFaxDownloadStart as a positive
response for host to commence download of fax data.
This state is not host settable. The object
FAXJOB-DOWNLOAD-ID now contains the job ID to be used
to track the progress of this fax job.
eFaxDownloadAborted - indicates the fax download activity
has been prematurely terminated by the device due to
some error. Object FAX-DOWNLOAD-ERROR contains the
error reason for the premature session termination.
This state is device settable from eFaxDownloadStart or
eFaxDownloadActive. This state is not host settable. If
modem transmission of fax data has started for this
download, the fax session will also be aborted.
eFaxDownloadDone - indicates the fax download activity has
reached a successful termination in that the device has
accepted all the download data from the host. This state is
only settable by the device from eFaxDownloadActive. This state
is not host settable. This state does not indicate the
progress of the modem transmission of the downloaded fax data.
Host should transition from this state to eFaxDownloadIdle in
order to reset the handshake mechanism for subsequent
download."
::= { settings-fax-proc-sub 6 }
fax-silent-detection OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "When enabled, this object causes the FAX machine to assume that
the caller is a FAX even though the line has remained silent
for a time (i.e., no CNG detected). When disabled, a CNG is
required of the caller."
::= { settings-fax-proc-sub 7 }
fax-ring-enable OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "When the phone line rings, this object determines whether an
audible ring shall be emitted."
::= { settings-fax-proc-sub 8 }
fax-country OBJECT-TYPE
SYNTAX INTEGER {
eChina(6),
eMexicoAndLatinAmerica(13),
eCanadaFrench(14),
eUnitedStatesAndCanadaEnglish(15),
eNewZealand(19),
eIsrael(21),
eAustralia(23),
eMalaysia(27),
eHongKong(29),
eSingapore(30),
eUnitedKingdom(31),
eAustria(34),
eNetherlands(35),
eSwitzerlandFrench(37),
eGermany(39),
eDenmark(40),
eSweden(41),
eNorway(43),
eIreland(44),
eBelgium(45),
eFinland(46),
eFrance(47),
eItaly(51),
eSpain(55),
ePoland(56),
eHungary(62),
eUkraine(63),
eRussia(64)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Note: Non-backwards compatible change make in version 4.7.
Returns which country the telephone-electronics (LIU) is
configured for. If this object is implemented with an access of
read-write the device POS will specify what occurs when this
object is written."
::= { settings-fax-proc-sub 9 }
fax-tx-phone-number OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION "Phone number about to be dialed."
::= { settings-fax-proc-sub 10 }
fax-redial-time OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Number of seconds one must wait between the current redial (set
by FAX-WHICH-REDIAL) and any prior dialing."
::= { settings-fax-proc-sub 14 }
fax-pstn-access-code OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "The code used within a PBX to get access to an outside PSTN
line. Typically this is ''9''."
::= { settings-fax-proc-sub 18 }
fax-rx-disposition OBJECT-TYPE
SYNTAX INTEGER {
ePrintOnly(1),
eUploadOnly(2),
eUploadElsePrint(4),
eForwardElsePrint(6)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates what is to be done with the incoming fax call.
ePrintOnly - New fax arrivals only go to the printer. If
printer becomes unavailable, the fax is stored in
device memory until the printer becomes available. If
device memory becomes full, no subsequent calls will be
answered. If power is cycled on the device, the user
must be informed of any lost faxes. If faxes are saved
in non-volatile memory, then they will be printed upon
successful power-up.
eUploadOnly - New fax can only be uploaded to the host. If
host becomes unavailable, the fax is stored in device
memory until host becomes available again to upload. If
device memory becomes full, no subsequent calls will be
answered. If power is cycled on the device, the user
must be informed of any lost faxes. If faxes are saved
in non-volatile device memory, the host must be
informed of a need to upload saved faxes upon
successful power up.
eUploadAndPrint - Received faxes are to be printed and also
uploaded to the host. The fax is stored in device
memory until it has been printed and uploaded. If
device memory becomes full, no subsequent calls will be
answered. If power is cycled on the device, the user
must be informed of any lost faxes. If faxes were saved
into non-volatile memory, then faxes must be printed
and uploaded before erasure from device memory.
eUploadElsePrint - Received faxes are to be uploaded if
host is available, otherwise the fax is printed. During
an upload, if the host becomes unavailable, the
remainder of the fax is printed. Once the host is
detected to be unavailable, the object will transition
to ePrintOnly. Refer to fax reception behavior for
ePrintOnly.
ePrintElseUpload - Received faxes are to be printed. If
printer is unavailable, the fax will be uploaded. If
printer becomes unavailable while the fax is being
received, the remainder unprinted pages of the fax will
be uploaded. If host then becomes unavailable, this
object will transition to ePrintOnly. Remainder pages
of the fax being uploaded will be stored in device
memory, to be printed when printer becomes available.
If device memory becomes full, no subsequent calls will
be answered. If power is cycled on the device, the user
must be informed of any lost faxes.
eForwardElsePrint - Received faxes are to be forwarded to
another fax station. If remote number does not answer,
fax is printed. If remote number is busy on multiple
redial attempts, the fax is printed. If device memory
becomes full before fax reception is complete, the fax
is printed. If printer becomes unavailable, the fax is
stored in device memory and then printed when printer
becomes available again. "
::= { settings-fax-proc-sub 19 }
fax-error-correction-mode OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates whether the device is configured to send and receive
faxes in error correction mode (ECM). This object controls both
receiving and transmitting in ECM. A value of eDisabled means
ECM is off and the device will not advertise the ability to do
ECM during negotiation with other fax machines. A value of
eEnabled means ECM is on and the device will advertise its
ability to do ECM. Changing this setting may or may not take
affect on the immediate page or ensuing pages of the document
currently being sent."
::= { settings-fax-proc-sub 21 }
fax-report-transmission OBJECT-TYPE
SYNTAX INTEGER {
eNone(1),
ePrintReport(2),
ePrintReportOnSend(3),
ePrintReportOnError(4),
ePrintReportOnSendError(5),
ePrintReportOnReceiveError(6)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Provides a host application with the ability to print a fax
transmission report. The supported enumerations are:
eNone - no transmission report printed
ePrintReport - transmission report always printed
ePrintReportOnSend - transmission report printed on send
only
ePrintReportOnError - transmission report printed on error
only
ePrintReportOnSendError - transmission report printed on
send error only
ePrintReportOnReceiveError - transmission report printed on
receive error only. "
::= { settings-fax-proc-sub 22 }
fax-report-activity-log OBJECT-TYPE
SYNTAX INTEGER {
eNever(1),
eThreshold(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Specifies when a report of fax transactions is to be printed.
eNever - to never print a transaction report.
eThreshold - to automatically print a transaction report
every N transactions.
The POS for each product shall specify the value of N.
FAX-REPORT-TRANSMISSION also prints a transaction report,
but for only a given fax, not a log of fax activities.
May not be settable if the fax machine is not idle.
The log is cleared after each printing caused by this
object. "
::= { settings-fax-proc-sub 23 }
fax-dial-tone-detection OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Determines whether the fax machine waits for a dial tone before
dialing a fax number. eEnabled - causes the fax machine to wait
until a dial tone is recognized before attempting to dial a fax
number. eDisabled - causes the fax machine to dial without
waiting to recognize a dial tone."
::= { settings-fax-proc-sub 24 }
fax-alarm-volume OBJECT-TYPE
SYNTAX INTEGER(0..3)
ACCESS read-write
STATUS optional
DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest
possible. A device shall divide this value into ranges
corresponding to the possible volumes and document these
settings and their meanings in the product POS.
Additional information:
For this LaserJet MFP the range is 0..3, where 0=off (silent),
1=soft, 2=medium, and 3=loud."
::= { settings-fax-proc-sub 25 }
fax-beep-volume OBJECT-TYPE
SYNTAX INTEGER(0..3)
ACCESS read-write
STATUS optional
DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest
possible. A device shall divide this value into ranges
corresponding to the possible volumes and document these
settings and their meanings in the product POS.
Additional information:
For this LaserJet MFP the range is 0..3, where 0=off (silent),
1=soft, 2=medium, and 3=loud."
::= { settings-fax-proc-sub 26 }
fax-ring-volume OBJECT-TYPE
SYNTAX INTEGER(0..3)
ACCESS read-write
STATUS optional
DESCRIPTION "Range is 0..100, where 0 = quietest possible, and 100 = loudest
possible. A device shall divide this value into ranges
corresponding to the possible volumes and document these
settings and their meanings in the product POS.
Additional information:
For this LaserJet MFP the range is 0..3, where 0=off (silent),
1=soft, 2=medium, and 3=loud."
::= { settings-fax-proc-sub 27 }
fax-master-host OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Identifies the hostname of the master host to which the device
is connected."
::= { settings-fax-proc-sub 28 }
fax-thumbnail-enable OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Controls whether or not a thumbnail reprint of the first page
of a fax shall be included on the fax call report. When set to
eEnabled a thumbnail shall be included on the report. When set
to eDisabled there shall be not be a thumbnail on the fax call
report.
Additional information:
Controls whether or not a thumbnail reprint of the
first page of a fax shall be included on the
fax call report. When set to eEnabled a thumbnail shall
be included on the report. When set to eDisabled there
shall be not be a thumbnail on the fax call report."
::= { settings-fax-proc-sub 29 }
fax-phone-pickup-enable OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This object is included to handle the situation where a fax
machine and a telephone share the same phone line. If a call
picked up at the phone turns out to be a fax call, the user may
initiate a fax receive via the fax machine front panel (with,
say, a button press). When this object is set to eEnabled and a
fax call is answered at the phone, the user has the option of
initiating the fax receive in the usual way at the fax front
panel or by entering a (product-specific) key sequence on the
telephone keypad (e.g. '***'). The device POS must indicate
what the key sequence is for a particular product. When this
object is set to eDisabled and a fax call is answered at the
phone, the user may only initiate the fax receive by taking the
product-specific action (such as a button press) at the fax
machine front panel. It is necessary to be able to turn this
feature off (i.e. set it to eDisabled) because the key sequence
of a particular fax device may interfere with other devices
connected to the phone line (e.g. an answering machine).
Additional information:
On this LaserJet MFP, the key sequence to initiate a fax from the
phone keypad is '***'."
::= { settings-fax-proc-sub 30 }
fax-adf-scan-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages scanned for
faxing from the ADF. In order to write this object
SERVICE-PASSWORD must be set correctly.
Additional information:
This object tracks the page count for the pages scanned for faxing
from the ADF. In order to write this object SERVICE-PASSWORD must be
set correctly."
::= { settings-fax-proc-sub 31 }
fax-print-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages sent to the
print engine for fax jobs. In order to write this object
SERVICE-PASSWORD must be set correctly.
Additional information:
This object tracks the page count for the pages sent to the print
engine for fax jobs. In order to write this object SERVICE-PASSWORD
must be set correctly."
::= { settings-fax-proc-sub 32 }
fax-download-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages downloaded to
the peripheral for fax jobs. In order to write this object
SERVICE-PASSWORD must be set correctly.
Additional information:
This object tracks the page count for the pages downloaded to the
peripheral for fax jobs. In order to write this object SERVICE-PASSWORD
must be set correctly."
::= { settings-fax-proc-sub 33 }
fax-upload-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages uploaded from
the peripheral for fax jobs. In order to write this object
SERVICE-PASSWORD must be set correctly.
Additional information:
This object tracks the page count for the pages uploaded from the
peripheral for fax jobs. In order to write this object SERVICE-PASSWORD
must be set correctly."
::= { settings-fax-proc-sub 34 }
fax-flatbed-scan-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages scanned for
faxing from the flatbed. In order to write this object the
SERVICE-PASSWORD must be set.
Additional information:
This object tracks the page count for the pages scanned
for faxing from the flatbed. In order to write this
object the SERVICE-PASSWORD must be set."
::= { settings-fax-proc-sub 36 }
default-fax-glass-size OBJECT-TYPE
SYNTAX INTEGER {
eUSLetter(2),
eUSLegal(3),
eISOandJISA4(26)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates the default fax glass size.
Additional information:
Indicates the default fax glass size."
::= { settings-fax-proc-sub 37 }
fax-cold-reset-fax-glass-size OBJECT-TYPE
SYNTAX INTEGER {
eUSLetter(2),
eUSLegal(3),
eISOandJISA4(26)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the fax glass size that is used as the
DEFAULT-FAX-GLASS-SIZE when a cold reset occurs.
Additional information:
Returns or sets the fax glass size that is used as the
DEFAULT-FAX-GLASS-SIZE when a cold reset occurs."
::= { settings-fax-proc-sub 38 }
fax-upload OBJECT-TYPE
SYNTAX INTEGER {
eFaxUploadIdle(1),
eFaxUploadStart(2),
eFaxUploadActive(3),
eFaxUploadAborted(4),
eFaxUploadDone(5),
eFaxUploadNeeded(6)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Note: The enumeration values for this object where changed in a
non-backwards compatible manner in version 4.7. Handshake
mechanism between host and device to notify and coordinate the
transfer of fax image data received by the device fax modem.
This object serves both as an indicator of fax upload activity
as well as a trigger for the host to alter fax upload progress.
Handshake mechanism between host and device to initiate scan
operation and coordinate the transfer of scanned image data to
the host. This object serves both as an indicator of scan
upload activity as well as a trigger for the host to alter scan
upload progress.
eFaxUploadIdle - indicates no fax upload activity is is
occurring. Device powers up in this state but will
otherwise never transition to this state of its own
accord. Host setting to eFaxUploadIdle while object is
in eFaxUploadActive will cause download activity to be
prematurely terminated. Host setting to this state
resets the handshake mechanism to permit another fax
upload activity to be initiated.
eFaxUploadStart - indicates the host requests to commence
an upload session for a received fax. This state is
host settable only from eFaxUploadIdle. Device will
never transition to this state of its own accord.
eFaxUploadActive - indicates a fax upload is occurring.
This state is not host settable. Device will transition
to this state from eFaxUploadStart as a positive
response for host to commence upload of fax data. The
object FAXJOB-UPLOAD-ID now contains the job ID.
eFaxUploadAborted - indicates the fax upload activity has
been prematurely terminated by the device due to some
error. Object FAX-UPLOAD-ERROR contains the error
reason for the premature session termination. This
state is device settable from eFaxUploadStart,
eFaxUploadActive or eFaxUploadNeeded. This state is not
host settable.
eFaxUploadDone - indicates the fax upload activity has
reached a successful termination in that the device has
transmitted all the upload data to the host. This state
is only settable by the device from eFaxUploadActive.
This state is not host settable. Host should transition
from this state to eFaxUploadIdle in order to reset the
handshake mechanism for subsequent upload session.
eFaxUploadNeeded - indicates device has received fax modem
data available for host upload. This state is not host
settable. This state is device settable from
eFaxUploadIdle. Host should respond by setting to
eFaxUploadStart to initiate upload session. Should host
fail to respond by the time fax reception is complete
or device has exhausted local memory storage, device
shall transition object from eFaxUploadNeeded to
eFaxUploadAborted. The POS should state the recourse
behavior associated with the received fax. "
::= { status-fax-proc-sub 1 }
fax-min-rings-pickup OBJECT-TYPE
SYNTAX INTEGER(1..1)
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates the minimum legal rings before pickup."
::= { status-fax-proc-sub 2 }
fax-max-rings-pickup OBJECT-TYPE
SYNTAX INTEGER(1..10)
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates the maximum legal rings before pickup."
::= { status-fax-proc-sub 3 }
fax-max-redials OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Maximum number of allowed redials."
::= { status-fax-proc-sub 4 }
fax-additional-wait OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Number of additional seconds to wait before beginning a
FAX-DOWNLOAD."
::= { status-fax-proc-sub 5 }
fax-download-error OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Error status of the fax download session."
::= { status-fax-proc-sub 6 }
fax-upload-error OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Error status of the fax upload session."
::= { status-fax-proc-sub 7 }
fax-firmware-revision OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
ACCESS read-only
STATUS optional
DESCRIPTION "This object identifies the fax firmware ROM revision code. The
format is device specific and shall be specified in the device
POS.
Additional information:
This object identifies the fax firmware ROM revision
code. For this LaserJet MFP, the format for this object is a date
in the form YYYYMMDD."
::= { status-fax-proc-sub 8 }
fax-forwarding-phone-num OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Phone number digits of the remote fax station where arrived
faxes are to be forwarded."
::= { fax-forwarding 3 }
fax-resolution OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..64))
ACCESS read-write
STATUS optional
DESCRIPTION "struct {
unsigned_32bit x_res; /* 1st four bytes; big endian */
unsigned_32bit y_res; /* 2nd four bytes; big endian */
}
Sets the send fax resolution. The x and y resolutions in
this object are in fixed-point with 16 bits of
fraction, and 16 bits of integer, and are in dots per
inch. X is horizontal; Y is vertical. Examples of
computing x_res and y_res: 300 dots/inch:round(300 *
65536) = 19660800
16 dots/mm: round(16 *25.4 * 65536) = 26633830.
If the device does not support the given combination, then
it'll select the nearest supported values in a device-dependent
manner (documented in the POS).
Additional information:
This LaserJet MFP supports 4 fax resolutions. As far as the
end-user is concerned these resolutions are: standard,
fine, superfine, and photo. Photo is not really a
resolution--see more below. Standard is the default.
Resolutions map as follows (values are given in dots per
inch (dpi) horizontal X vertical (x X y)): standard(203
X 98), fine(203 X 196), superfine(300 X 300), and
photo(300 X 300).
Supported resolutions in hex notation (dpi, x X y) are:
standard(00cb0000 X 00620000), fine(00cb0000 X 00c4000),
superfine(012C0000 X 012C0000), and photo(012C0000 X
012C0000).
The device ignores attempts to set invalid resolutions.
Photo is not a resolution, but photo setting depends on
whether half-toning is on or off. In the case of this LaserJet MFP
photo setting doesn't actually change the bits going out
the modem -- still one bit per pixel so photo and
superfine are the same.
NOTE: The last 16 bits of the horizontal and vertical
settings are ignored. Only the first 16 bits of the
horizontal and vertical resolution setting are used."
::= { settings-fax-send 1 }
fax-contrast OBJECT-TYPE
SYNTAX INTEGER(-127..127)
ACCESS read-write
STATUS optional
DESCRIPTION "Behaves as SCL's 'Set Scanner Contrast Level' command which is
used for setting the sending fax contrast level. Range is
0..100.
Additional information:
Behaves as COPIER-CONTRAST and SCANNER-CONTRAST.
Contrast values can range from -127 to +127, for a total
of 255 contrast values. Within that range, this LaserJet MFP
supports 11 values. They are: -5, -4, -3, -2,
-1, 0, 1, 2, 3, 4, 5. The default contrast level is 0
(normal). A positive value results in a larger
difference, and a negative value results in a smaller
difference.
This LaserJet MFP snaps unsupported values toward zero as follows:
<=-125 snaps to -5
>-125 and <=-100 snaps to -4
>-100 and <=-75 snaps to -3
>-75 and <=-50 snaps to -2
>-50 and <=-25 snaps to -1
>-25 and <25 snaps to 0
>=25 and <50 snaps to 1
>=50 and <75 snaps to 2
>=75 and <100 snaps to 3
>=100 and <125 snaps to 4
>=125 snaps to 5"
::= { settings-fax-send 2 }
fax-pixel-data-type OBJECT-TYPE
SYNTAX INTEGER {
eBiLevelThesholded(1),
eBiLevelHalfToned(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Sets the scanning method used when sending a fax.
eBiLevelThesholded - One bit per pixel, using simple
thresholding of greyscale scan data. eBiLevelHalfToned - One
bit per pixel, using some kind of half-toning technique (such
as dithering or error-diffusion) to approximate greyscale scan
data."
::= { settings-fax-send 3 }
not-ready-fax-send OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates if the sending fax sub-system in the device is not
ready. If there are no items in the collection (i.e. no bits
are set), then the sending fax sub-system is ready. If there is
an item present, then the item indicates what is causing the
sending fax sub-system to be not ready."
::= { status-fax-send 1 }
fax-allow-redials OBJECT-TYPE
SYNTAX INTEGER {
eFalse(1),
eTrue(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "When eTrue, the FAX machine can redial a phone number if the
prior call failed for some reason. When eFalse, such redialing
will not occur.
Additional information:
This object is not used for this LaserJet MFP products."
::= { transmit-fax 3 }
hrMemorySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The amount of physical main memory contained by
the host.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The unit of measure for this object is 1024
bytes. The default value assumes the base printer with no
additional memory."
::= { hrStorage 2 }
hrStorageIndex OBJECT-TYPE
SYNTAX INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each logical storage area
contained by the host.
Refer to RFC 1514, Host Resources MIB, for more details."
::= { hrStorageEntry 1 }
hrStorageType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The type of storage represented by this entry.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The object is constant for the product."
::= { hrStorageEntry 2 }
hrStorageDescr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "A description of the type and instance of the
storage described by this entry.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
This object is not localized. For the product, this
object is constant."
::= { hrStorageEntry 3 }
hrStorageAllocationUnits OBJECT-TYPE
SYNTAX INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The size, in bytes, of the data objects allocated
from this pool. If this entry is monitoring
sectors, blocks, buffers, or packets, for example,
this number will commonly be greater than one.
Otherwise this number will typically be one.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
Unit is one byte. For the product,
this object is constant."
::= { hrStorageEntry 4 }
hrStorageSize OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The size of the storage represented by this entry,
in units of hrStorageAllocationUnits.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
Total formatter RAM. (The value of this object
is hrMemorySize times the unit of measure for hrMemorySize.
For this procduct this is 65536*1024 bytes.)"
::= { hrStorageEntry 5 }
hrStorageUsed OBJECT-TYPE
SYNTAX INTEGER(0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "The amount of the storage represented by this
entry that is allocated, in units of
hrStorageAllocationUnits.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
This object returns the amount of memory in use
by the printer at the current time. This object should not
be used when creating a print job for the device because the
amount of memory in use will likely be different when the
printer processes the print job."
::= { hrStorageEntry 6 }
hrStorageAllocationFailures OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The number of requests for storage represented by
this entry that could not be honored due to not
enough storage. It should be noted that as this
object has a SYNTAX of Counter, that it does not
have a defined initial value. However, it is
recommended that this object be initialized to
zero.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
This object is set to zero at power on and when
any reset is done via prtGeneralReset.
This object is incremented whenever the printer is short on
memory (codewise: when PersMemoryCycle is called with a
parameter of 2)."
::= { hrStorageEntry 7 }
hrDeviceIndex OBJECT-TYPE
SYNTAX INTEGER(1..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION "A unique value for each device contained by the
host. The value for each device must remain
constant at least from one re-initialization of the
agent to the next re-initialization.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The entry in the Device Table which describes
the printer."
::= { hrDeviceEntry 1 }
hrDeviceType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION "An indication of the type of device.
If this value is `hrDeviceProcessor { hrDeviceTypes
3 }' then an entry exists in the hrProcessorTable
which corresponds to this device.
If this value is `hrDeviceNetwork { hrDeviceTypes 4
}', then an entry exists in the hrNetworkTable
which corresponds to this device.
If this value is `hrDevicePrinter { hrDeviceTypes 5
}', then an entry exists in the hrPrinterTable
which corresponds to this device.
If this value is `hrDeviceDiskStorage {
hrDeviceTypes 6 }', then an entry exists in the
hrDiskStorageTable which corresponds to this
device.
Refer to RFC 1514, Host Resources MIB, for more details."
::= { hrDeviceEntry 2 }
hrDeviceDescr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION "A textual description of this device, including
the device's manufacturer and revision, and
optionally, its serial number.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The serial number is not returned with this
object. This object is not localized."
::= { hrDeviceEntry 3 }
hrDeviceID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The product ID for this device.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The complete OID reported by this object is:
.1.3.6.1.4.1.11.2.3.9.1.2.48.3"
::= { hrDeviceEntry 4 }
hrDeviceStatus OBJECT-TYPE
SYNTAX INTEGER {
eHrunning(2),
eHwarning(3),
eHdown(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current operational state of the device
described by this row of the table. A value
unknown(1) indicates that the current state of the
device is unknown. running(2) indicates that the
device is up and running and that no unusual error
conditions are known. The warning(3) state
indicates that agent has been informed of an
unusual error condition by the operational software
(e.g., a disk device driver) but that the device is
still 'operational'. An example would be high
number of soft errors on a disk. A value of
testing(4), indicates that the device is not
available for use because it is in the testing
state. The state of down(5) is used only when the
agent has been informed that the device is not
available for any use.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The printer's condition is mapped as follows:
eHrunning -- Printer ready to print or is printing. It may
be in power save mode.
eHwarning -- A condition exists that needs attention, but it
is not currently preventing printing. A non-critical alert
is active.
eHdown -- Printer is not printing because it is offline, or
a critical alert is active. Human interaction is needed to
bring the printer to a ready state."
::= { hrDeviceEntry 5 }
hrDeviceErrors OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION "The number of errors detected on this device. It
should be noted that as this object has a SYNTAX
of Counter, that it does not have a defined
initial value. However, it is recommended that
this object be initialized to zero.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
This is the number of critical alerts that have
been entered into the alert table since the device was
powered on. The maximum value for this object is 2^32-1. At
power-on, this object will be set to zero."
::= { hrDeviceEntry 6 }
hrPrinterStatus OBJECT-TYPE
SYNTAX INTEGER {
eHother(1),
eHidle(3),
eHprinting(4),
eHwarmup(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "The current status of this printer device. When
in the idle(1), printing(2), or warmup(3) state,
the corresponding hrDeviceStatus should be
running(2) or warning(3). When in the unknown
state, the corresponding hrDeviceStatus should be
unknown(1).
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The printer's condition is mapped as follows:
eHother -- The printer is offline, or a critical alert is
active.
eHidle -- The printer is not performing any of the items
listed under eHprinting status.
eHprinting -- A job is currently being processed or printed,
or a PJL job is being processed.
eHwarmup -- If hrDeviceStatus is eHdown, the printer is
currently offline but is resolving the condition that caused
it to be offline. It will be online when it is ready to
print. If hrDeviceStatus is eHrunning, the printer was
in power save mode and is now becoming ready to print. (In
the product, this status only occurs very
briefly at boot time. At no other time does the printer
report 'eHwarmup' status.)"
::= { hrPrinterEntry 1 }
hrPrinterDetectedErrorState OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION "This object represents any error conditions
detected by the printer. The error conditions are
encoded as bits in an octet string, with the
following definitions:
Condition Bit # hrDeviceStatus
lowPaper 0 warning(3)
noPaper 1 down(5)
lowToner 2 warning(3)
noToner 3 down(5)
doorOpen 4 down(5)
jammed 5 down(5)
offline 6 down(5)
serviceRequested 7 warning(3)
If multiple conditions are currently detected and
the hrDeviceStatus would not otherwise be
unknown(1) or testing(4), the hrDeviceStatus shall
correspond to the worst state of those indicated,
where down(5) is worse than warning(3) which is
worse than running(2).
Bits are numbered starting with the most
significant bit of the first byte being bit 0, the
least significant bit of the first byte being bit
7, the most significant bit of the second byte
being bit 8, and so on. A one bit encodes that
the condition was detected, while a zero bit
encodes that the condition was not detected.
This object is useful for alerting an operator to
specific warning or error conditions that may
occur, especially those requiring human
intervention.
Refer to RFC 1514, Host Resources MIB, for more details.
Additional information:
The product reports error
conditions as follows:
noPaper - A tray is empty and must be filled for printing to
continue.
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
A critical alert is active.
coverOpen -- A cover or door is open.
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
A critical alert is active.
jammed -- A jam condition is preventing printing.
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
A critical alert is active.
offline -- Printer is offline and will not accept new print
jobs until it is online. This condition is rare in the
and may indicate some other error.
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
A critical alert is active.
serviceRequested -- Any status or error condition not listed
above. These fall into two categories:
(1) If the condition prevents printing, the 'offline' bit
is also set and status values are as for offline. i.e.:
hrDeviceStatus = eHdown;
hrPrinterStatus = eHother;
A critical alert is active.
(2) If the condition does not prevent printing the status
values are:
hrDeviceStatus = eHwarning;
hrPrinterStatus = eHidle or eHprinting;
A non-critical alert is active.
lowToner -- The product can report this condition.
noToner -- The product can report this condition."
::= { hrPrinterEntry 2 }
npCRCTable OBJECT-TYPE
SYNTAX SEQUENCE OF NpCRCEntry
ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { npCard 15 }
npCRCEntry OBJECT-TYPE
SYNTAX NpCRCEntry
ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { npCRCTable 1 }
npCRCIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION ""
::= { npCRCEntry 1 }
npCRCText OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION ""
::= { npCRCEntry 2 }
npCRCChannel OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION ""
::= { npCRCEntry 3 }
inetTrapDestinationNum OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "Total number of ACTIVE rows in the inetTrapDestination table."
::= { inetTrapDestination 1 }
inetTrapDestinationTable OBJECT-TYPE
SYNTAX SEQUENCE OF InetTrapDestinationEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "List of inetTrap destinations to which the agent sends traps."
::= { inetTrapDestination 2 }
inetTrapDestinationEntry OBJECT-TYPE
SYNTAX InetTrapDestinationEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "Entries are inetAddress Specific sequence of trap destination parameters."
::= { inetTrapDestinationTable 1 }
inetTrapRowIndex OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "Row Index of the inetTrapDestination table"
::= { inetTrapDestinationEntry 1 }
inetTrapRowStatus OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "Individual Row Status
1 - Row is Active - Row is activated and ready.
2 - Not-In-Service - Row is suspended.
3 - Not Ready - Row is not activated and still needs some columnar values to move to ready state.
4 - Create and Go - This is set when the client uses multivarbind request to configure the trap table.
5 - Create and Wait - This is set when the client does sequential configuration of the trap table.
6 - Destroy - This is set when the client wants to delete the row from the table.
"
::= { inetTrapDestinationEntry 2 }
inetTrapAddressType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION "Protocol family for trap. Possible values:
ipv4(1) An IPv4 address as defined by the
InetAddressIPv4 textual convention.
ipv6(2) An IPv6 address as defined by the
InetAddressIPv6 textual convention.
dns(16) A DNS domain name as defined by the
InetAddressDNS textual convention."
::= { inetTrapDestinationEntry 3 }
inetTrapAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "IPv4/IPv6/FQDN address of trap destination node."
::= { inetTrapDestinationEntry 4 }
inetTrapPort OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "Port number of the inetTrap Destination to which the trap is sent."
::= { inetTrapDestinationEntry 5 }
inetTrapCommunityName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "Trap community name specified in the trap packet."
::= { inetTrapDestinationEntry 6 }
inetTrapVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS current
DESCRIPTION "Trap version, one of the following
0 = snmpV1
1 = snmpV2
3 = Inform
Default is 1 = snmpV2.
This value remains persistent through a powercycle."
::= { inetTrapDestinationEntry 7 }
inetTrapStyle OBJECT-TYPE
SYNTAX INTEGER {selectable-pml-traps(1),
aps-and-general-or-nrdpe-traps(2),
both-of-the-above(3)}
ACCESS read-write
STATUS current
DESCRIPTION "This OID is read-write.
If the user wants to receive only the PML traps, then trapStyle can be set to 1.
If the user wants to receive only APS and General or NOT-READY-DESTINATION-PRINT-ENGINE traps, then trapStyle can be set to 2.
If the user wants to receive the both kinds of above traps, then trapStyle can be set to 3."
::= { inetTrapDestinationEntry 8 }
inetTrapPMLOids OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "This OID is a read-write. This will have tokens of PML trappable OIDs.
Each token (OID) will be separated by a semi-colon. If a trap destination entry is
registered for only APS and general/NRDPE traps, then the pmlTrapOids OID will be a NULL string."
::= { inetTrapDestinationEntry 9 }
inetTrapErrorValue OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "Gives the error value in case if the server is not able to send the traps
to the configured trapDestination entry. It will be set to below defined error values
if there the agent finds any error while dispatching a trap.
10 - Invalid value for rowStatus. Should be 1, 2, 3 or 6.
11 - Ivalid value for InetTrapAddressType. Should be 1, 2 or 16.
12 - Invalid for IP Address or FQDN.
13 - Ivalid value for inetTrapPort. Should be greater than 0 or less than 65536.
14 - Invalid valur for inetTrapCommunityName.
15 - Invalid value for inetTrapVersion. Should be 0, 1 or 3.
16 - Invalid value for inetTrapStyle. Should be either 1, 2 or 3.
17 - Unable to resgister SOME or ALL PML trappable OIDs.
51 - InetTrapAddressType & InetTrapAddress does not macth.
52 - It is a Duplicate entry.
53 - Unable to move the row to ACTIVE state because of insufficient/invalid entries.
80 - Unable to resolve name: no DNS server.
81 - Unable to resolve name: no DNS records present for name.
82 - Unable to resolve name: no dns records matching FQDN Resolution Value.
"
::= { inetTrapDestinationEntry 10 }
inetTrapTest OBJECT-TYPE
SYNTAX Integer32
ACCESS write-only
STATUS current
DESCRIPTION "Causes agent to send an snmp trap to hosts registered in the trap
destination table. Value specified will be used as the specific
trap id."
::= { inetTrapDestination 3 }
inetTrapFilterDelay OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "The purpose of the trap filter feature is to prevent multiple traps
of the same specificTrapId to be sent within a short period of time.
This object assigns the period of time within which a duplicate trap
will be blocked. This value is in 1/10 second intervals and the default
value is set to 50 corresponding to 5 seconds.
This value remains persistent through a powercycle."
::= { inetTrapDestination 4 }
inetTrapBaseTimeout OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "Applicable only if trapVersion is set to Inform.
Units are 1/10 second intervals. Default is 2
corresponding to 200 milliseconds. This value corresponds
to the time of the first retry following the initial inform
request. Additional retries are sent at times corresponding to
the retry number multiplied by the inetTrapBaseTimeout.
This value remains persistent through a powercycle."
::= { inetTrapDestination 5 }
inetTrapRetryNum OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "Applicable only if trapVersion is set to Inform.
This is the maximum number of inform retries that will be sent to
this destination. Retries are sent if no inform reply is received
within the timeout value. The timeout value is calculated as
described under inetTrapBaseTimeout.
This value remains persistent through a powercycle."
::= { inetTrapDestination 6 }
inetTrapFQDNResolution OBJECT-TYPE
SYNTAX INTEGER {resolve-for-IPv4-address(1),
resolve-for-IPv6-address(2),
resolve-for-both(10)}
ACCESS read-write
STATUS current
DESCRIPTION "The purpose of this field is to configure various options for resolving FQDN.
If configured as 1 - then FQDN names will be resolved for IPv4 addresses only
If configured as 2 - then FQDN names will be resolved for IPv6 addresses only.
If configured as 10 - then FQDN names will be resolved for both IPv4 and IPv6 addresses."
::= { inetTrapDestination 7 }
inetTrapFQDNMultipleAddressBehavior OBJECT-TYPE
SYNTAX INTEGER {send-to-first-resolved-address(1),
send-to-all-resolved-address(2)}
ACCESS read-write
STATUS current
DESCRIPTION "1 - Send traps to the first resolved address
2 - Send traps to all resolved address.
"
::= { inetTrapDestination 8 }
inetTrapUseDNSCache OBJECT-TYPE
SYNTAX INTEGER {enable(1),
disable(0)}
ACCESS read-write
STATUS current
DESCRIPTION "Depending upon the value of this field resolution of FQDN will happen everytime when a trap is sent."
::= { inetTrapDestination 9 }
trapDestinationNum OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "The number of trap destinations."
::= { trapDest 1 }
trapDestinationTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapDestinationEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "Protocol specific list of destinations
to which the agent sends traps."
::= { trapDest 2 }
trapDestinationEntry OBJECT-TYPE
SYNTAX TrapDestinationEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "Entries are a protocol specific sequence of trap
destination parameters."
::= { trapDestinationTable 1 }
trapTest OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "Causes agent to send an snmp trap to hosts registered in the trap
destination table. Value specified will be used as the specific
trap id."
::= { trapDest 3 }
trapSource OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "Sets the agent internal source for traps. Possibilities are as follows:
0 = ALL_TRAPS_ON
1 = ASYNC_PERIPHERAL_STATUS traps only
2 = proprietary PML traps only
3 = alert table traps only
This object was changed to read-only to accommodate the SNMPv3
Notifiaction tables requirement to recieve all traps. SNMPv3 tags
are used to filter SNMP Trap sources."
::= { trapDest 4 }
trapFilterDelay OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "The purpose of the trap filter feature is to prevent multiple traps
of the same specificTrapId to be sent within a short period of time.
This object assigns the period of time within which a duplicate trap
will be blocked. This value is in 1/10 second intervals and the default
value is set to 50 corresponding to 5 seconds. This value remains
persistent
through a powercycle."
::= { trapDest 5 }
trapFQDNNum OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "Number of trapFQDNTable rows."
::= { trapDest 6 }
trapFQDNTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapFQDNEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "The trap destination entries can be mapped to destination's FQDN name in this table."
::= { trapDest 7 }
trapFQDNEntry OBJECT-TYPE
SYNTAX TrapFQDNEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "An FQDN destination entry indexed by the destination's IP address."
::= { trapFQDNTable 1 }
trapIPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS current
DESCRIPTION "The trap destination IP address."
::= { trapFQDNEntry 1 }
trapFQDN OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "The trap destination's FQDN. This will be resolved to IP address(es) at trap destination time."
::= { trapFQDNEntry 2 }
setCommunityName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "This object controls access of snmp read-write requests. Factory
default configuration provides authentication of incoming packets
with community names: internal and public. This object overrides the
factory default settings so that the factory default setttings no longer
work. This object returns SET or NOT_SET."
::= { community 1 }
getCommunityName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "This object controls access of snmp read requests. Factory
default configuration provides authentication of incoming packets
with community names: internal and public. This object provides
access in addition to the factory default settings. If
set, then authentication will succeed with any of the following
community names: internal, public, getCommunityName, or
setCommunityName. This object returns SET or NOT_SET."
::= { community 2 }
npSysStatusMessage OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION "A status string reflecting the current state of the card
and peripheral."
::= { npSys 2 }
npSysModelNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION "The HP model number of the device."
::= { npSys 10 }
npSysNetworkConnectors OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This object describes the network connectors supported by the
device. The value is a bit mask. A set bit indicates the
connector is supported.
Bit Value Connector
0 0x01 Ethernet, BNC
1 0x02 Ethernet, AUI
2 0x04 Ethernet, RJ-45
3 0x08 TokenRing, DB-9
4 0x10 TokenRing, RJ-45
5 0x20 LocalTalk
6 0x40 100VG, RJ-45
7 0x80 100T, RJ-45"
::= { npSys 11 }
npSysCardServices1 OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This object is a bitmap showing what services are available
on the card.
Bit 0 - IPX/SPX/NCP protocol stack
Bit 1 - IP/TCP protocol stack
Bit 2 - LLC/DLC protocol stack
Bit 3 - Ethertalk protocol stack
Bit 4 - IPv6 protocol stack
Bit 5 - IPSec protocol stack
Bits 6 - 11 Reserved
Bit 12 - LPD print services
Bit 13 - FTP print services
Bit 14 - Port 9100 print services
Bit 15 - IPP print services
Bits 16 - 23 Reserved
Bit 24 - Queue Server Bindery
Bit 25 - Queue Server NDS
Bit 26 - Remote Printer
Bit 27 - SPX Direct Mode
Bit 28 - DLC Print Services
Bit 29 - EtherTalk Print Services
Bits 30 - 31 Reserved"
::= { npSys 16 }
npSysCardServices2 OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This object is a bitmap showing what services are available
on the card.
Bit 0 - XIP2
Bit 1 - PML Get/Set
Bit 2 - PML Traps
Bit 3 - Scan to Web Browser
Bit 4 - Scan to Email
Bit 5 - MFP Scan Support
Bits 6 - 11 Reserved
Bit 12 - Telnet API
Bit 13 - Web API
Bit 14 - SNMP V2
Bit 15 - SNMP Traps
Bit 16 - Download
Bit 17 - TFTP
Bit 18 - RCFG
Bit 19 - SLP
Bit 20 - Syslog
Bit 21 - DHCP
Bit 22 - BOOTP
Bit 23 - RARP
Bit 24 - SNMP V3
Bit 25 - SSL Functionality
Bit 26 - Auto IP
Bits 27 - 31 Reserved"
::= { npSys 17 }
npSysCardServices3 OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This object is a bitmap showing what services are available
on the card.
Bit 0 - 100T
Bit 1 - Token Ring 802.5
Bit 2 - 802.11b
Bit 3 - 80211.a
Bit 4 - Bluetooth
Bits 5 - 11 Reserved
Bit 12 - EIO. For embedded Jetdirect this bit will be 1.
Bit 13 - LIO
Bit 14 - USB
Bit 15 - Firewire
Bit 16 - TCP Download
Bits 17 - 31 Reserved"
::= { npSys 22 }
npConnsIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS current
DESCRIPTION "Remote IP address of the node currently connected to the card.
Zero if no connection is active."
::= { npConns 11 }
npCfgSource OBJECT-TYPE
SYNTAX INTEGER {manual-one(1),
bootp-two(2),
manual-three(3),
bootp-four(4),
dhcp(5),
not-configured(6),
default-config(7),
rarp(8),
read-only(9),
auto-ip(10)}
ACCESS read-write
STATUS current
DESCRIPTION "This object indicates how the device obtained its IP configuration."
::= { npCfg 1 }
npCfgYiaddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION "The IP address assigned to the card from the BOOTP reply
yiaddr field."
::= { npCfg 2 }
npCfgSiaddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS current
DESCRIPTION "The IP address of the TFTP server from the BOOTP reply
siaddr field."
::= { npCfg 3 }
npCfgLogServer OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION "The IP address of the Syslog Server. If set via BOOTP (Tag: 7 field,
lg=<ipaddress> ) then SNMP set will fail. If not set via BOOTP then SNMP set
will succeed. Value saved across warm boot power cycles. BOOTP will always
overwrite SNMP set values."
::= { npCfg 5 }
npCfgSyslogFacility OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This specifies the facility identifier used in syslog messages
generated by the card."
::= { npCfg 6 }
npCfgAccessState OBJECT-TYPE
SYNTAX INTEGER {allowed(1),
not-allowed(2)}
ACCESS read-only
STATUS current
DESCRIPTION "An indication of whether or not the requesting host
is allowed to connect to the card as dictated by the
access list."
::= { npCfg 7 }
npCfgAccessListNum OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "The number of access list entries."
::= { npCfg 8 }
npCfgAccessListTable OBJECT-TYPE
SYNTAX SEQUENCE OF NpCfgAccessListEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "List of access addresses and masks."
::= { npCfg 9 }
npCfgAccessListEntry OBJECT-TYPE
SYNTAX NpCfgAccessListEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "Each entry contains an access address and mask."
::= { npCfgAccessListTable 1 }
npCfgAccessListIndex OBJECT-TYPE
SYNTAX Integer32 (0..9)
ACCESS read-only
STATUS current
DESCRIPTION "Index to the configuration access list table."
::= { npCfgAccessListEntry 1 }
npCfgAccessListAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION "The Access List Address contains the list of hosts or network
of hosts that are allowed to connect to the print server over ip.
When setting this object npCfgAccessListAddrMask should also
be set in the same varbind packet. NpCfgAccessListAddress
should always preceed npCfgAccessListAddrMask in the set packet.
If npCfgAccessListAddrMask is not set, the default value of
255.255.255.255 will be assigned to npCfgAccessListAddrMask
for that particular npCfgAccessListAddress entry. Duplicate host
addresses are possible and, once set, it is not possible to change
any particular row other than to clear the Access List Table.
To clear the Access List Table set npCfgAccessListAddress to 0.0.0.0.
This table has a maximum of 10 rows."
::= { npCfgAccessListEntry 2 }
npCfgAccessListAddrMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION "Address mask used to help determine whether or not a given
IP address is allowed access to the print server. An IP address
is allowed access if (Addr & AddrMask) == (IP & AddrMask).
A set of this object may only be done if npCfgAccessListAddress
preceeds it in the same varbind packet."
::= { npCfgAccessListEntry 3 }
npCfgSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION "The subnet mask associated with the IP address of this card."
::= { npCfg 12 }
npCfgDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION "This variable contains the IP address of the default router for this
card."
::= { npCfg 13 }
npCfgDomainName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "The print server domain name."
::= { npCfg 16 }
npCfgIPP OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "Below are the different values accepted by this OID.
0 - Disable IPP and IPP-S
1 - Enable IPP and IPP-S
2 - Enable IPP-S only
3 - Enable IPP only
"
::= { npCfg 18 }
npCfgWINSNameServerIdPri OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS current
DESCRIPTION "Primary name server for NetBIOS over TCP/IP."
::= { npCfg 22 }
npCfgPasswd1Verify OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "Compares string value to passwd1 and returns OK if match,
GENERAL ERROR if doesn't match."
::= { npCfg 28 }
npCfgPasswd1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS current
DESCRIPTION "Password for root or administrator. Get request returns
either 'SET' or 'NOT_SET'."
::= { npCfg 29 }
npCfgBanner OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Line Printer Daemon Protocol (LPD) banner page per I/O port.
(0) = Disabled
(1) = Enabled
Enabled by default."
::= { npCfg 31 }
npCfgLinkType OBJECT-TYPE
SYNTAX INTEGER {autoNegotiate(1),
full10T(2),
half10T(3),
full100T(4),
half100T(5),
auto100T(6),
full1000T(7)}
ACCESS read-write
STATUS current
DESCRIPTION "Network link speed and communication mode."
::= { npCfg 35 }
npCfgSnmpDefaultReadCmnty OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Controls Default Read Community Name access.
(0) = Disabled, i.e., default get community names FAIL to access target.
(1) = Enabled, i.e., default get community names SUCCEED to access target."
::= { npCfg 40 }
npCfgBonjourServiceName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "The name by which all the Jetdirect services will be advertised by
Multicast Domain Name System (Bonjour). Must set a non empty string"
::= { npCfg 44 }
npCfgBonjourDomainName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION "The name used as the 'target name' in the DNS SRV records by
Multicast Domain Name System (Bonjour)."
::= { npCfg 46 }
npCfgIPv6DomainName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "IPv6 Domain Name."
::= { npCfg 49 }
npCfgIPv6ConfigState OBJECT-TYPE
SYNTAX INTEGER {ipv6-going-down(0),
ipv6-is-up(1)}
ACCESS read-only
STATUS current
DESCRIPTION "IPv6 stack status event; IPv6 enabled/disabled."
::= { npCfg 50 }
npCfgIPv6DNSAddr1 OBJECT-TYPE
SYNTAX InetAddress
ACCESS read-write
STATUS current
DESCRIPTION "IPv6 DNS Address, priority 1."
::= { npCfg 56 }
npCfgIPv6DNSAddr2 OBJECT-TYPE
SYNTAX InetAddress
ACCESS read-write
STATUS current
DESCRIPTION "IPv6 DNS Address, priority 2."
::= { npCfg 57 }
npCfgIPConfigPrecedence OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "Allows to set uniform rules for parameter overwrite by
different configuration methods.
0 - Manual
1 - TFTP
2 - DHCPv4/Bootp
3 - DHCPv6 - only if ipv6 is supported
3/4 - Default - 4 if ipv6 is supported otherwise 3
The set string should be 0:1:2:3:4 (or 0:1:2:3 when ipv6 is not supported)
or any colon separated combination of the 5 (or 4) integral values. The
string should contain all integral values atleast and atmost once."
::= { npCfg 59 }
npCfgPortConfig OBJECT-TYPE
SYNTAX INTEGER {half10T(10),
full10T(11),
half100T(12),
full100T(13),
full1000T(19)}
ACCESS read-only
STATUS current
DESCRIPTION "Network link speed and communication mode."
::= { npCfg 65 }
npTcpTFTPFileName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION "The TFTP configuration file name."
::= { npTcp 9 }
npTcpTFTPServerId OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS current
DESCRIPTION "TFTP server from which configuration
information is obtained."
::= { npTcp 10 }
npTcpSyslogMax OBJECT-TYPE
SYNTAX Integer32 (0..1000)
ACCESS read-write
STATUS current
DESCRIPTION "Maximum number of syslog packets to be sent
per minute. 0 = Disabled."
::= { npTcp 11 }
npTcpAppSyslogPriority OBJECT-TYPE
SYNTAX Integer32 (0..8)
ACCESS read-write
STATUS current
DESCRIPTION "Priority below which the syslog messages will
not be sent.
Valid priority levels = 0 through 7.
Disabled = 8."
::= { npTcp 12 }
npCtlReconfig OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "Writing any value to this variable causes the card to
reconfigure itself by doing the BOOTP/TFTP configuration
activity."
::= { npCtl 8 }
npCtlProtocolSet OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "This is a 4 byte integer value. The least significant bytes
represent the protocols on the card. A value of '1' indicates
a protocol that is enabled. A value of '0' indicates a
protocol that is disabled.
The 32-bit protocol enable 'structure' is defined as:
bits 31-28: Number of I/O channels/protocols present (NUM_CHAN)
bits 27-24: Number of I/O channels which may operate concurrently
(NUM_OP_CHAN)
bits 23-16: unused, reserved
bits 15-1: Individual I/O channel/protocol enable bits,
0 == disable, 1 == enable
MIO_IOCHAN_NOVELL bit 1
MIO_IOCHAN_LLC bit 2
MIO_IOCHAN_TCP bit 3
MIO_IOCHAN_ATALK bit 4
MIO_IOCHAN_IPV6 bit 5
bit 0: When NUM_OP_CHAN == 1, auto-protocol select enable bit,
0 == disable, 1 == enable (APS_ON)"
::= { npCtl 9 }
npCtlSNMPEnableDisable OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "0 = SNMP disabled
1 = SNMP enabled
If SNMP is enabled, setting this object to 0 will
disable SNMP on the print server. Once disabled it is not
possible to enable SNMP via SNMP. When enabled,
a get request will return 1. SNMP may be enabled
via a different user interface, such as telnet or
the print server Embedded Web Server."
::= { npCtl 14 }
npCtlTelnet OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Configure Telnet service.
(0) = Telnet disabled
(1) = Telnet enabled"
::= { npCtl 19 }
npCtlFTP OBJECT-TYPE
SYNTAX Integer32 {
printDisable-downloadDisable(0),
printEnable-downloadEnable(1),
printEnable-downloadDisable(2),
printDisable-downloadEnable(3)
}
ACCESS read-write
STATUS current
DESCRIPTION "Configure File Transfer Protocol (FTP) service.
(0) = Both FTP Print and Download Disabled
(1) = Both FTP Print and Download Enabled
(2) = FTP Print Enabled and FTP Download Disabled
(3) = FTP Print Disabled and FTP Download Enabled
"
::= { npCtl 20 }
npCtlSLP OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Configure Service Location Protocol (SLP) service.
(0) = SLP disabled
(1) = SLP enabled"
::= { npCtl 21 }
npCtlLPD OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Configure Line Printer Daemon Protocol (LPD) service.
(0) = LPD disabled
(1) = LPD enabled"
::= { npCtl 22 }
npCtl9100 OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Configure TCP port 9100 printing.
(0) = port 9100 printing disabled
(1) = port 9100 printing enabled"
::= { npCtl 24 }
npCtlSysLog OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Configure Syslog service.
(0) = Syslog service disabled
(1) = Syslog service enabled
Enabled by default."
::= { npCtl 26 }
npCtlSnmpVersionAccess OBJECT-TYPE
SYNTAX INTEGER {snmpV1RW-snmpV3RW(1),
snmpV1RO-snmpV3RW(2),
snmpV1NoAccess-snmpV3RW(3),
snmpV1RW-snmpV3NoAccess(4),
snmpV1RO-snmpV3NoAccess(5)}
ACCESS read-write
STATUS current
DESCRIPTION "Manages an SNMP version's read and write access to the MIB."
::= { npCtl 27 }
npCtlSnmpV3InitAccount OBJECT-TYPE
SYNTAX INTEGER {destroy(0),
blockInitEncrypt(4)}
ACCESS read-write
STATUS current
DESCRIPTION "Used to create initial SNMPv3 account. The following rules apply:
0 = clear init account, only if previously 0.
4 = Block init account, only cold reset will clear or use Web User interface.
Setting this object to blocked (4) will block an initial account
creation until a cold reset."
::= { npCtl 28 }
npCtlBonjour OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Configure Multicast Domain Name Service.
(0) = Bonjour disabled
(1) = Bonjour enabled"
::= { npCtl 29 }
npCtlNetworkConnectionMode OBJECT-TYPE
SYNTAX INTEGER {auto-cable-detect(1),
disable-radio(2),
disable-wired(3)}
ACCESS read-write
STATUS current
DESCRIPTION "This object controls the selection of the active network
interface used for communication. This is applicable to
products supporting dual wired and wireless network interfaces"
::= { npCtl 32 }
npCtlIPSecurityPolicy OBJECT-TYPE
SYNTAX INTEGER {disable(0),
enable(1)}
ACCESS read-write
STATUS current
DESCRIPTION "Disable IP Security (IPSec) or Firewall. Only disabling is allowed."
::= { npCtl 34 }
npCtlWSDiscovery OBJECT-TYPE
SYNTAX INTEGER {disable(0),
enable(1)}
ACCESS read-write
STATUS current
DESCRIPTION "Web Services Discovery enable/disable."
::= { npCtl 36 }
npCtlWSPrint OBJECT-TYPE
SYNTAX INTEGER {disable(0),
enable(1)}
ACCESS read-write
STATUS current
DESCRIPTION "Web Services Print enable/disable."
::= { npCtl 37 }
npCtlLLMNR OBJECT-TYPE
SYNTAX INTEGER {disable(0),
enable(1)}
ACCESS read-write
STATUS current
DESCRIPTION "Link-Local Multicast Name Resolution( LLMNR ) enable/disable."
::= { npCtl 38 }
npCtlFpDot11WirelessState OBJECT-TYPE
SYNTAX INTEGER {disable(0),
enable(1)}
ACCESS read-write
STATUS current
DESCRIPTION "Use for enabling and disabling Wireless Radio.
The following values are defined:
Disable = 0
Enable = 1
Default = 1(Enabled)"
::= { npCtl 47 }
npCtlAirPrintStatus OBJECT-TYPE
SYNTAX INTEGER {disable(0),
enable(1)}
ACCESS read-write
STATUS current
DESCRIPTION " Use to Enabled/Disabled AirPrint functionality.
Disable = 0
Enable(Default) = 1
"
::= { npCtl 68 }
npCtlAllowRFC5746TLS-SSLCompatibilityMode OBJECT-TYPE
SYNTAX INTEGER {disable(0),
enable(1)}
ACCESS read-write
STATUS current
DESCRIPTION " Added to support RFC-5746.
This OID can be use to enable/disable legacy SSL renegotiation.
Disable = 0
Enable(Default) = 1
"
::= { npCtl 70 }
npPortNumPorts OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "The number of peripheral interfaces supported by this device."
::= { npPort 1 }
npDHCPserver OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS current
DESCRIPTION "IP address of DHCP server that provided this unit with an IP
address via the DHCP protocol."
::= { npDhcp 2 }
npDhcpFQDNBehavior OBJECT-TYPE
SYNTAX INTEGER {present-JD-Behavior(0),
rFC4702-compliant-Behavior(1)}
ACCESS read-write
STATUS current
DESCRIPTION "This object defines the FQDN behavior in Jetdirect. Set this to
( 0 ) - Present Jetdirect Behavior
( 1 ) - RFC 4702 compliant behavior"
::= { npDhcp 4 }
npWebProxyServerId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "IP address or hostname of web proxy server."
::= { npWeb 12 }
npWebProxyServerPort OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "IP port of web proxy server"
::= { npWeb 13 }
npWebProxyUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "Proxy web user identification"
::= { npWeb 14 }
npWebProxyUserPasswd OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "Proxy web user password"
::= { npWeb 15 }
npWebCheckACLforHTTP OBJECT-TYPE
SYNTAX Integer32 (0..1)
ACCESS read-write
STATUS current
DESCRIPTION "Configure checking of HTTP web connections against Access Control List.
(0) = Disable ACL checking
(1) = Enable ACL checking"
::= { npWeb 17 }
npSecurityDot11ServerAuthentication OBJECT-TYPE
SYNTAX INTEGER {eap-md5(1),
eap-tls(2),
leap(4),
peap(8),
ttls(16)}
ACCESS read-write
STATUS current
DESCRIPTION "Server-Based Authentication with the following bitwise values:
None(0),
EAP-MD5(1),
EAP-TLS(2),
LEAP(4),
PEAP(8),
TTLS(16)"
::= { npSecurity 1 }
npSecurityDot1xEapMd5Identity OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "Radius MD5 authentication User Name."
::= { npSecurity 2 }
npSecurityDot1xTLSAuthServerId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "TLS authentication Server ID."
::= { npSecurity 3 }
npSecurityPublicKey OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION "The public key of a public/private key pair to be
used by applications to set encrypted values."
::= { npSecurity 4 }
npSecurityDot11EncryptedDot11NetworkName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS current
DESCRIPTION "The encrypted network name (SSID). Use the
npSecurityPublicKey to encrypt this value.
Setting this object will cause the card to reconfigure."
::= { npSecurity 5 }
npSecurityDot11EncryptedDot1xEapMd5Secret OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS current
DESCRIPTION "The encrypted dot1xEapMD5Secret authentication password.
Use the npSecurityPublicKey to encrypt this value.
Setting this object will cause the card to reconfigure."
::= { npSecurity 6 }
npSecurityDot11EncryptedWEPKeyTable OBJECT-TYPE
SYNTAX SEQUENCE OF NpSecurityDot11EncryptedWEPKeyEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "Encrypted interface to the WEP Keys."
::= { npSecurity 7 }
npSecurityDot11EncryptedWEPKeyEntry OBJECT-TYPE
SYNTAX NpSecurityDot11EncryptedWEPKeyEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "Each row of the table gives a WEP Key"
::= { npSecurityDot11EncryptedWEPKeyTable 1 }
npSecurityDot11EncryptedWEPKey OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS current
DESCRIPTION "The encrypted WEP Key value. Use
the npSecurityDot11PublicKey to encrypt this value.
Setting this object will cause the card to reconfigure."
::= { npSecurityDot11EncryptedWEPKeyEntry 2 }
npSecurityDot11SignalStrength OBJECT-TYPE
SYNTAX INTEGER {level-1-TBD(1),
level-2-TBD(2),
level-3-TBD(3),
level-4-TBD(4),
level-5-TBD(5)}
ACCESS read-only
STATUS current
DESCRIPTION "A weighted average over time of the signal strength
between the access point and the print server in infrastructure
mode. Not applicable when in ad hoc mode."
::= { npSecurity 8 }
npSecurityDot11SSIDTable OBJECT-TYPE
SYNTAX SEQUENCE OF NpSecurityDot11SSIDEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "List of discovered SSIDs."
::= { npSecurity 9 }
npSecurityDot11SSIDEntry OBJECT-TYPE
SYNTAX NpSecurityDot11SSIDEntry
ACCESS not-accessible
STATUS current
DESCRIPTION "Each row of the table gives a discovered SSID value."
::= { npSecurityDot11SSIDTable 1 }
npSecurityDot11SSID OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION "A discovered SSID value."
::= { npSecurityDot11SSIDEntry 2 }
npSecurityDot11SSIDTableNumEntries OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "Displays the number of discovered SSIDs in
the SSID Table."
::= { npSecurity 10 }
npSecurityDot11SSLCertLoaded OBJECT-TYPE
SYNTAX INTEGER {true(1),
false(2)}
ACCESS read-only
STATUS current
DESCRIPTION "Indicates if SSL certificate has been loaded."
::= { npSecurity 11 }
npSecurityDot11TLSCertLoaded OBJECT-TYPE
SYNTAX INTEGER {true(1),
false(2)}
ACCESS read-only
STATUS current
DESCRIPTION "Indicates if TLS Trusted CA certificate has been loaded."
::= { npSecurity 12 }
npSecuritySnmpV3EncryptedUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS current
DESCRIPTION "The encrypted SNMPv3 User Name.
Use the npSecurityPublicKey to encrypt this value.
The new SNMPv3 User Account will be installed after the
npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase
and npSecuritySnmpV3PrivKeyPassPharse have been set."
::= { npSecurity 13 }
npSecuritySnmpV3AuthKeyPassPhrase OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS current
DESCRIPTION "The encrypted SNMPv3 Authentication passphrase or key .
Use the npSecurityPublicKey to encrypt this value.
The new SNMPv3 User Account will be installed after the
npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase
and npSecuritySnmpV3PrivKeyPassPharse have been set.
Set npSecuritySnmpV3AuthAlgorithm, npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase
to the required values before setting this OID.
"
::= { npSecurity 14 }
npSecuritySnmpV3PrivKeyPassPharse OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS current
DESCRIPTION "The encrypted SNMPv3 Privacy passphrase or key.
Use the npSecurityPublicKey to encrypt this value.
The new SNMPv3 User Account will be installed after the
npSecuritySnmpV3EncryptedUserName, npSecuritySnmpV3AuthKeyPassPhrase
and npSecuritySnmpV3PrivKeyPassPharse have been set.
Set npSecuritySnmpV3AuthAlgorithm, npSecuritySnmpV3PrivAlgorithm and npSecuritySnmpV3PassPhrase
to the required values before setting this OID.
"
::= { npSecurity 15 }
npSecurityDot11BSSID OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION "The BSSID value (hardware address of the access point)."
::= { npSecurity 16 }
npSecurityDot1xTunnelAuthBits OBJECT-TYPE
SYNTAX INTEGER {eap-md5(1),
eap-mschap(2),
eap-mschapv2(4),
mschap(8),
mschapv2(16),
eap-gtc(32)}
ACCESS read-write
STATUS current
DESCRIPTION "The Dot1x Tunnel Authentication Bits. Bitwise field
with the followings bits:
Default All bits cleared
EAP MD5 1
EAP MSCHAP 2
EAP MSCHAPv2 4
MSCHAP 8
MSCHAPv2 16
EAP GTC 32"
::= { npSecurity 17 }
npSecurityDot1xIdentityCleartext OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "The Dot1x Identity in cleartext."
::= { npSecurity 18 }
npSecurityDot11ExactMatchServerId OBJECT-TYPE
SYNTAX INTEGER {true(1),
false(2)}
ACCESS read-write
STATUS current
DESCRIPTION "Indicates if an exact match is required on the EAP Server ID."
::= { npSecurity 19 }
npSecurityDot11EncryptionStrength OBJECT-TYPE
SYNTAX INTEGER {low(1),
medium(2),
high(3)}
ACCESS read-write
STATUS current
DESCRIPTION "Indicates the EAP encrytpion strength."
::= { npSecurity 20 }
npSecurityCertBuff OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION "A 512 byte buffer of the print server certificate as indexed by
npSecurityCertBuffIndex."
::= { npSecurity 21 }
npSecurityCertBuffIndex OBJECT-TYPE
SYNTAX INTEGER {block1(1),
block2(2),
block3(3),
block4(4),
block5(5),
block6(6)}
ACCESS read-write
STATUS current
DESCRIPTION "Indicates the index of the 512 byte block of the print server
certificate to load into npSecurityCertBuff."
::= { npSecurity 22 }
npSecuritySslRedirection OBJECT-TYPE
SYNTAX INTEGER {redirectionEnabled(1),
redirectionDisabled(2)}
ACCESS read-write
STATUS current
DESCRIPTION "Setting this object causes the SSL redirection connection
to be enabled or disabled."
::= { npSecurity 23 }
npSecurityReset OBJECT-TYPE
SYNTAX INTEGER {set(0),
reset(1)}
ACCESS read-write
STATUS current
DESCRIPTION "Setting this object causes security object to reset bact to the defaults."
::= { npSecurity 24 }
npSecurityWebSpiEnable OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-write
STATUS current
DESCRIPTION "This object enables/disables the Embedded Web Simple Printer Install feature."
::= { npSecurity 25 }
npSecurityDot11WEPStrength OBJECT-TYPE
SYNTAX INTEGER {not-set(1),
strenth-40-bit(2),
strenth-104-bit(3)}
ACCESS read-only
STATUS current
DESCRIPTION "Indicates the encryption strength of the WEP keys."
::= { npSecurity 26 }
npSecurityServicesSupported OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "BITWISE indication of the 802.11 security services this device supports.
The following bits are defined:
MD5 (0)
TLS (1)
TTLS (2)
LEAP (3)
PEAP (4)
Reserved (5 - 15)
WEP (16)
WPA (17)
AES (18)
WPA2 (19)
AUTO_FOR_WEP_SUPPORTED (20)
AUTO_FOR_WPA_SUPPORTED (21)
AUTO_FOR_ENCRYPTION_SUPPORTED (22)
Reserved (23 - 31)"
::= { npSecurity 27 }
npSecurityDot11Encryption OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "802.11 encryption method currently enabled.
The following values are defined:
NONE (0x00)
SSN/WEP (0x01)
TKIP (0x02)
AES (0x03)
AUTO (0x04)
Reserved (5 - 31)
It is advised not to use dot11PrivacyInvoked OID anymore, instead use npSecurityDot11Encryption.
Since Jetdirect updates the same variable when the set happens through any of the two OIDs and
npSecurityDot11Encryption is more versatile, it is recommended to use this OID.
"
::= { npSecurity 28 }
npSecurityDot11MulticastCipher OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS current
DESCRIPTION "BITWISE indication of the multicast cipher method currently enabled.
At minimum, one bit must be set.
The following bits are defined:
WEP (0)
WPA (1)
Reserved (2 - 31)"
::= { npSecurity 29 }
npSecurityDot11BeaconTableNumEntries OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "Displays the number of discovered SSIDs in the DOT11 Beacon Table."
::= { npSecurity 34 }
npSecurityDot11OpenSSIDEnabled OBJECT-TYPE
SYNTAX TruthValue
ACCESS read-only
STATUS current
DESCRIPTION "Indicates if the Open SSID is enabled (Spirit-only)."
::= { npSecurity 35 }
npSecurityDot11EncryptedWPAConfigPSKPassPhrase OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS current
DESCRIPTION "The encrypted WPA Config PSK PassPhrase. Use the
npSecurityPublicKey to encrypt this value"
::= { npSecurity 36 }
npSecurityDot11DataRate OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "Current wireless network data rate"
::= { npSecurity 37 }
npSecurityDot11ScanComplete OBJECT-TYPE
SYNTAX INTEGER {true(1),
false(2)}
ACCESS read-write
STATUS current
DESCRIPTION "Used to control scan for SSIDs in the wireless network.
Set to false to initiate a scan. A value of true indicates
the completion of the scan"
::= { npSecurity 38 }
npSecurityDot11RoamThreshold OBJECT-TYPE
SYNTAX INTEGER {no-signal(1),
very-weak-signal(2),
weak-signal(3)}
ACCESS read-write
STATUS current
DESCRIPTION "Used to control roaming by the wireless radio. The radio on
the print server will roam or try to find an access point with
a stronger signal once the signal strength from the associated
access point reaches the specified roam threshold level."
::= { npSecurity 39 }
npSecuritySslEncryptionStrength OBJECT-TYPE
SYNTAX INTEGER {low(1),
medium(2),
high(3)}
ACCESS read-write
STATUS current
DESCRIPTION "The SSL Encryption Strength."
::= { npSecurity 40 }
npSecurityDot11InstantVerification OBJECT-TYPE
SYNTAX INTEGER {disable(0),
enable(1)}
ACCESS read-write
STATUS current
DESCRIPTION "Enable and disable wireless instant verification.
(0) = Disable
(1) = Enable"
::= { npSecurity 41 }
npSecurityDot11DynamicEncryption OBJECT-TYPE
SYNTAX INTEGER {nONE(0),
bASIC(1),
wPA(2),
wPA2(3),
aUTO(4)}
ACCESS read-write
STATUS current
DESCRIPTION "WPA mode.
(0x00) = NONE
(0x01) = BASIC
(0x02) = WPA
(0x03) = WPA2
(0x04) = AUTO"
::= { npSecurity 42 }
npSecurityDot11LinkAuthentication OBJECT-TYPE
SYNTAX INTEGER {open(1),
shared-key(2),
leap(128),
auto(143)}
ACCESS read-write
STATUS current
DESCRIPTION "DOT11 Link Authentication modes.
(1) = OPEN
(2) = SHARED-KEY
(128) = LEAP
(143) = AUTO
We can set the Link Authentication using the object dot11AuthenticationAlgorithmsEnable ( OID: 1.2.840.10036.1.2.1.3.x )
Since the dot11AuthenticationAlgorithsmEnable object does not supports setting of AUTO option, we provide this object.
Through this OID you can set to any one of the above options.
Whereas using the dot11AuthenticationAlgorithmsEnable object we can set either OPEN OR SHARED mode only."
::= { npSecurity 43 }
npSecuritySnmpV3AuthAlgorithm OBJECT-TYPE
SYNTAX INTEGER {md5(2),
sha-1(3)}
ACCESS read-write
STATUS current
DESCRIPTION "Indicates the Authentication Algorithm used.
It can have the value MD5 or SHA-1.
This key will have a default value set to MD5.
The following values are defined:
MD5 2 (Default)
SHA-1 3
"
::= { npSecurity 44 }
npSecuritySnmpV3PrivAlgorithm OBJECT-TYPE
SYNTAX INTEGER {des(2),
aes-128(3)}
ACCESS read-write
STATUS current
DESCRIPTION "Indicates the Privacy Algorithm used.
It can have the value DES or AES-128.
This key will have a default value set to DES.
The following values are defined:
DES 2 (Default)
AES-128 3
"
::= { npSecurity 45 }
npSecurityDot1xFailSafe OBJECT-TYPE
SYNTAX INTEGER {enable(1),
disable(0)}
ACCESS read-write
STATUS current
DESCRIPTION "After configuring 802.1x on the printer and switching it over to a secured network, if authentication is
successful printer retains connectivity and if it fails it loses connectivity.
In case of authentication failure, it does not acquire connectivity even when switched over to an unsecured network.
802.1x failsafe is a feature which allows printer to retain connectivity in a unsecured network even if authentication fails.
Setting this OID to 1 enables this feature and setting to 0 disables this feature.
Connect anyway (802.1x Fail-Safe) ( 1 )
Block network (secure failure) ( 0 )
"
::= { npSecurity 57 }
gdStatusBytes OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "The number of valid bytes in the gdStatusEntry
array."
::= { generalDeviceStatus 1 }
gdStatusDisplay OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS current
DESCRIPTION "The string diplayed on the peripheral front panel.
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this is always a zero length string."
::= { generalDeviceStatus 3 }
gdStatusId OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS current
DESCRIPTION "A formatted string of NVT ASCII
charactersdescribing this peripheral."
::= { generalDeviceStatus 7 }
gdStatusJobTimeout OBJECT-TYPE
SYNTAX Integer32
ACCESS read-write
STATUS obsolete
::= { generalDeviceStatus 10 }
gdPasswords OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS current
DESCRIPTION "This object is used as a 256 byte NVRAM area for JetAdmin. It
is completely managed by JetAdmin. Initially it is initialized
to all zeros. A coldboot will re-initialize to all zeros."
::= { generalDeviceStatus 13 }
pmlTrapEnable OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS current
DESCRIPTION "This OID is used to enable individual peripheral trappable objects through the print server."
::= { netPMLtrap 1 }
pmlTrapDisable OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS current
DESCRIPTION "This OID is used to disable individual peripheral trappable objects through the print server."
::= { netPMLtrap 2 }
npNpiPaeClass OBJECT-TYPE
SYNTAX INTEGER {printer(1),
plotter(2),
xStation(3)}
ACCESS read-only
STATUS current
DESCRIPTION "The class assigned to the peripheral onto which
this card is plugged."
::= { npNpiPeripheralAttributeEntry 2 }
npNpiPaeIdentification OBJECT-TYPE
SYNTAX INTEGER {laserjet-IIISI(1),
laserjet-4SI(5)}
ACCESS read-only
STATUS current
DESCRIPTION "The Identification number of the peripheral. These values are
defined in the MIO spec. DesignJet, PaintJet XL300, and
DesignJet/600 peripherals will identify themselves as
LaserJet-IIIsi."
::= { npNpiPeripheralAttributeEntry 3 }
npNpiCaeClass OBJECT-TYPE
SYNTAX INTEGER {rs-232(1),
centronics(2),
csma-cd-network(3),
token-ring-network(4),
scsi(5),
hpib(6),
localtalk(7),
hpna(8),
usb(9),
firewire(10),
bluetooth(11),
ieee802-11b(12)}
ACCESS read-only
STATUS current
DESCRIPTION "The class of this network peripheral card."
::= { npNpiCardAttributeEntry 2 }
gdStatusLineState OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This describes the line state of the peripheral.
When non-zero, the peripheral is off-line. When
zero the peripheral is on-line."
::= { gdStatusEntry 1 }
gdStatusPaperState OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This describes the state of the paper on the peripheral.
When non-zero, the peripheral has a paper problem. When
zero, the peripheral does not have a paper problem."
::= { gdStatusEntry 2 }
gdStatusInterventionState OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This describes the intervention state of the
peripheral. When non-zero, the peripheral requires
human intervention to continue working. When
zero, it requires no assistance."
::= { gdStatusEntry 3 }
gdStatusPeripheralError OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This is the error code from the peripheral."
::= { gdStatusEntry 6 }
gdStatusPaperOut OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral is out of paper.
off (0),
paper-out-or-paper-mount (1),
manual-paper-feed-needed (2)
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 8 }
gdStatusPaperJam OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral has a paper jam.
off (0),
paper-jam(1)
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 9 }
gdStatusTonerLow OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral has a low toner condition.
off (0),
toner-low (1),
no-toner-cartridge (2)
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 10 }
gdStatusPagePunt OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral did not receive data fast
enough to keep up with the print engine when generating a page.
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 11 }
gdStatusMemoryOut OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral did not have enough memory
to render an image on a page.
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 12 }
gdStatusIoActive OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral is processing data from
this I/O interface card. For some peripherals, such as the
HP LaserJet IIISi printer or HP DesignJet plotter,
this value is always a zero (0).
For X.20.06 firmware and later firmware releases, this object is
not relevant. In order not to break legacy applications which call this
object in multi-varbind requests, this value is always zero (0)."
::= { gdStatusEntry 13 }
gdStatusBusy OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral is busy processing
print/plot data.
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 14 }
gdStatusWait OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral is waiting for print/plot
data to process.
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 15 }
gdStatusInitialize OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral is initializing or
warming up.
off (0),
initializing (1),
warm-up(2)
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 16 }
gdStatusDoorOpen OBJECT-TYPE
SYNTAX Integer32 (0..255)
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral cover or door is open.
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 17 }
gdStatusPrinting OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral is printing or otherwise
marking or moving paper.
off (0),
ordinary-page (1),
test-fonts-config-or-start-page (2)
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 18 }
gdStatusPaperOutput OBJECT-TYPE
SYNTAX Integer32
ACCESS read-only
STATUS current
DESCRIPTION "This indicates that the peripheral has a paper output problem
such as the output storage bin being full.
off (0),
output-storage-full (1)
For some peripherals, such as the HP LaserJet IIISi printer
or HP DesignJet plotter, this value is always a zero (0)."
::= { gdStatusEntry 19 }
photo-access-card-error OBJECT-TYPE
SYNTAX INTEGER {
ePhotoCardAccessNoError(0),
ePhotoCardSmartMediaUpsideDown(1),
ePhotoCardMediaNotFullyInserted(2),
ePhotoCardMoreThenOneInSlots(3),
ePhotoCardReadError(4),
ePhotoCardRemovedWhileReading(5),
ePhotoCardBadFileWhilePrinting(6),
ePhotoCardNotInSlot(7),
ePhotoCardContainsNoPhotos(8),
ePhotoCardWriteError(9),
ePhotoCardRemovedWhileWriting(10),
ePhotoCardUnknownError(999)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Specifies the error reason for most recent unsucessful photo
card access.
Additional information:
Specifies the error reason for most recent unsucessful photo
card access."
::= { photo-job 2 }
photo-default-num-copies OBJECT-TYPE
SYNTAX INTEGER(1..99)
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the default number of copies to be printed
during photo application print jobs. This value is saved over a
power cycle.
Additional information:
Reads or writes the default number of copies to be
printed during photo application print jobs. This value is
saved over a power cycle."
::= { settings-photo-job 1 }
photo-job-num-copies OBJECT-TYPE
SYNTAX INTEGER(1..99)
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the number of copies to be printed during the
next photo application print job. This value is not saved over
power cycles.
Additional information:
Reads or writes the number of copies to be printed
during the next photo application print job. This value is
not saved over a power cycle."
::= { settings-photo-job 2 }
photo-job-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSLetter(2),
eISOandJISA4(26)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the default media size to be used during the
next photo application print job. This value is not saved over
power cycles.
Additional information:
Reads or writes the default media size to be
used during the next photo application print job. This
value is not saved over a power cycle."
::= { settings-photo-job 4 }
photo-job-media-name OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the media type to be used on the next photo
application print job. This value is not saved over power
cycles.
Additional information:
Reads or writes the media type to be used on the next
photo application print job. This value is not saved over a
power cycle."
::= { settings-photo-job 6 }
photo-image-size OBJECT-TYPE
SYNTAX INTEGER {
eThumbnail(1),
eWallet(2),
e3halfx5in(3),
e3x4in(4),
e4x6in(5),
e5x7in(6),
e6x8in(7),
e8x10in(8),
e6x8cm(9),
e7x10cm(10),
e9x13cm(11),
e10x15cm(12),
e13x18cm(13),
e15x21cm(14),
e18x24cm(15),
e20x25cm(16),
eFullPage(17),
ePanoramic(18)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the default image size to be used during photo
application print jobs. This value is saved over power cycles.
Additional information:
Reads or writes the default image size to be
used during photo application print jobs. This value is
saved over a power cycle. Valid image sizes are determined
by the PHOTO-IMAGE-SIZE-SET pml object."
::= { settings-photo-job 7 }
photo-job-image-size OBJECT-TYPE
SYNTAX INTEGER {
eThumbnail(1),
eWallet(2),
e3halfx5in(3),
e3x4in(4),
e4x6in(5),
e5x7in(6),
e6x8in(7),
e8x10in(8),
e6x8cm(9),
e7x10cm(10),
e9x13cm(11),
e10x15cm(12),
e13x18cm(13),
e15x21cm(14),
e18x24cm(15),
e20x25cm(16),
eFullPage(17),
ePanoramic(18)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the image size to be used during the next photo
application print job. This value is not saved over power
cycles.
Additional information:
Reads or writes the image size to be used during
the next photo application print job. This value is not
saved over a power cycle. Valid image sizes are determined
by the PHOTO-IMAGE-SIZE-SET pml object."
::= { settings-photo-job 8 }
photo-select-images OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the list of images to print during the next
photo application print job. Each image number or number range
must be separated by a comma. The image number corresponds to
the location of the file on the image card. For example, if
there are 10 images on the photo card, then you could select
'1-10' or '1,2,3,4,5' or '1,2,3,4-9'. The same image number can
also appear multiple times in the list. i.e.
'1,2,2,2,3,3,4,4,5'. This value is not saved over power cycles
and only applies to the next job.
Additional information:
Reads or writes the list of images to print
during the next photo application print job. Each image
number or number range must be separated by a comma. The
image number corresponds to the location of the file on
the image card. For example, if there are 10 images on
the photo card, then you could select 1-10 or 1,2,3,4,5 or
1,2,3,4-9. The same image number can also appear multiple
times in the list. i.e. 1,2,2,2,3,3,4,4,5. This value is
not saved over a power cycle, and only applies to the next
job."
::= { settings-photo-job 9 }
photo-images-on-card OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Reads the number of printable photo images found on the
inserted memory card. If 0, then no images were found, or the
card was not properly inserted.
Additional information:
Reads the number of printable photo images found
on the inserted memory card. If 0, then no images were
found, or the card was not properly inserted."
::= { settings-photo-job 10 }
photo-job-source OBJECT-TYPE
SYNTAX INTEGER {
ePhotoPrintProofSheet(1),
ePhotoScanProofSheet(2),
ePhotoPrintColorJob(3),
ePhotoPrintMonochromeJob(4),
ePhotoPrintIndexPrint(5)
}
ACCESS write-only
STATUS optional
DESCRIPTION "Controls initiating photo application features.
Additional information:
Controls initiating photo application features."
::= { settings-photo-job 11 }
photo-mono-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the page count for monochrome pages printed by
the photo application. This value is saved over power cycles.
Additional information:
Reads or writes the page count for monochrome pages
printed by the photo application. This value is saved over
a power cycle."
::= { settings-photo-job 13 }
photo-image-size-set OBJECT-TYPE
SYNTAX INTEGER {
eImageSizeSetInch1(1),
eImageSizeSetInch2(2),
eImageSizeSetCentimeter1(3),
eImageSizeSetCentimeter2(4),
eImageSizeSetCentimeter3(5)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This is only writable in service mode. This object changes the
set of valid image sizes for the device. The image sizes groups
are as follows:
eImageSizeSetInch1: Wallet, 3x4in, 3 1/2 x 5in, 4x6in,
5x7in, 8x10in, full page
eImageSizeSetInch2: Wallet, 3 1/2 x 5in, 4x6in, 5x7in,
6x8in, 8x10in, full page
eImageSizeSetCentimeter1: 6x8cm, 7x10cm, 9x13cm, 10x15cm,
13x18cm, 15x21cm, 20x25cm, full page
eImageSizeSetCentimeter2: 7x10cm, 9x13cm, 10x15cm, 13x18cm,
20x25cm, full page
eImageSizeSetCentimeter3: 6x8cm, 9x13cm, 10x15cm, 13x18cm,
15x21cm, 18x24cm, 20x25cm, full page .
Additional information:
This is only writable in service mode. This object
changes the set of valid image sizes for the device. The image
sizes groups are as follows:
eImageSizeSetInch1: Thumbnail, Wallet, 3x4in, 3 1/2 x 5in, 4x6in,
5x7in, 8x10in, full page, panorama
eImageSizeSetInch2: Thumbnail, Wallet, 3 1/2 x 5in, 4x6in, 5x7in,
6x8in, 8x10in, full page, panorama
eImageSizeSetCentimeter1: Thumbnail, 6x8cm, 7x10cm, 9x13cm, 10x15cm,
13x18cm, 15x21cm, 20x25cm, full page, panorama
eImageSizeSetCentimeter2: Thumbnail, 7x10cm, 9x13cm, 10x15cm, 13x18cm,
20x25cm, full page, panorama
eImageSizeSetCentimeter3: Thumbnail, 6x8cm, 9x13cm, 10x15cm, 13x18cm,
15x21cm, 18x24cm, 20x25cm, full page, panorama"
::= { settings-photo-job 15 }
photo-clear-counts OBJECT-TYPE
SYNTAX INTEGER {
eClearPageCounts(1),
eClearInsertCounts(2),
eClearAllCounts(3)
}
ACCESS write-only
STATUS optional
DESCRIPTION "writing this object causes the page counts, insert counts, or
all photo counts to be cleared and reset to 0.
Additional information:
writing this object causes the page counts, insert counts, or all photo counts
to be cleared and reset to 0."
::= { settings-photo-job 18 }
photo-compact-flash-insert-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the count for the number of times a compact
flash memory card has been inserted in the device. This value
is saved over a power cycle.
Additional information:
reads or writes the count for the number of times a compact flash memory card
has been inserted in the device. This value is saved over a power cycle."
::= { settings-photo-job 19 }
photo-memory-stick-insert-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the count for the number of times a memory
stick memory card has been inserted in the device. This value
is saved over a power cycle.
Additional information:
reads or writes the count for the number of times a memory stick memory card
has been inserted in the device. This value is saved over a power cycle."
::= { settings-photo-job 20 }
photo-memory-stick-pro-insert-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the count for the number of times a memory
stick pro memory card has been inserted in the device. This
value is saved over a power cycle.
Additional information:
reads or writes the count for the number of times a memory stick pro memory card
has been inserted in the device. This value is saved over a power cycle."
::= { settings-photo-job 21 }
photo-smart-media-insert-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the count for the number of times a smart media
memory card has been inserted in the device. This value is
saved over a power cycle.
Additional information:
reads or writes the count for the number of times a compact flash memory card
has been inserted in the device. This value is saved over a power cycle."
::= { settings-photo-job 22 }
photo-secure-digital-insert-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the count for the number of times a secure
digital memory card has been inserted in the device. This value
is saved over a power cycle.
Additional information:
reads or writes the count for the number of times a compact flash memory card
has been inserted in the device. This value is saved over a power cycle."
::= { settings-photo-job 23 }
photo-mmc-insert-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the count for the number of times a
MultiMediaCard memory card has been inserted in the device.
This value is saved over a power cycle.
Additional information:
reads or writes the count for the number of times a MultiMediaCard memory card
has been inserted in the device. This value is saved over a power cycle."
::= { settings-photo-job 24 }
photo-xd-insert-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Reads or writes the count for the number of times an xD-Picture
memory card has been inserted in the device. This value is
saved over a power cycle.
Additional information:
reads or writes the count for the number of times an xD-Picture memory card
has been inserted in the device. This value is saved over a power cycle."
::= { settings-photo-job 25 }
pe-test-photocard-manufacturing-errors OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Error status of the photocard manufacturing test.
Additional information:
Error status of the photocard manufacturing test."
::= { print-engine-test 90 }
pe-test-photocard-manufacturing-test-config OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS write-only
STATUS optional
DESCRIPTION "Configures the device for photocard manufacturing test mode.
Additional information:
Configures the device for photocard manufacturing test mode."
::= { print-engine-test 91 }
pe-test-photocard-data-input OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION "This object sets the value of the test string to be written to
the photocard.
Additional information:
This object sets the value of the test string to be
written to the photocard ."
::= { print-engine-test 95 }
pe-test-photocard-dir-input OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION "This object creates or opens a directory with the string name
on a photocard.
Additional information:
This object creates or opens a directory with the string
name on a photocard."
::= { print-engine-test 96 }
pe-test-photocard-file-input OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION "This object creates or opens a file with the string name on a
photocard.
Additional information:
This object creates or opens a file with the string name on a
photocard."
::= { print-engine-test 97 }
energy-star OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Returns or changes the Energy Star sleep value. If the value
is greater than zero, then the device will go into energy
saving sleep mode after the print engine has been idle for the
number of seconds specified by this object. A value of zero
means Energy Star is disabled and the device will not go to
sleep based on print engine idle time. The value must be
non-negative.
Additional information:
The product will always be in
sleep mode when not processing data. This object will
always return a value of 1."
::= { settings-system 1 }
sleep-mode OBJECT-TYPE
SYNTAX INTEGER {
eFalse(1),
eTrue(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Returns eTrue if the device is in energy saving sleep mode,
otherwise returns eFalse. Setting SLEEP-MODE to eFalse causes
the device to wake up, if it is in sleep mode. Setting
SLEEP-MODE to eTrue causes the device to go into sleep mode.
Additional information:
The product will always be in
sleep mode except when either processing a print job or
in an error state."
::= { settings-system 2 }
service-password OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS optional
DESCRIPTION "When set to the password value, other service related objects
become 'visible' (i.e readable) or become writable. When
written with any other value, the service related objects
become 'hidden' (i.e. are no longer readable) or are not longer
writable. The objects that can be effected by the
SERVICE-PASSWORD object include: SERIAL-NUMBER and
TOTAL-ENGINE-PAGE-COUNT. The password value, and the list of
objects effected by the SERVICE-PASSWORD being set to the
correct value, should be documented in the device POS.
Additional information:
The objects that can be effected by the SERVICE-
PASSWORD are: SCANNER-JAM-PAGE-COUNT, SCANNER-ADF-PAGE
-COUNT, SCAN-ADF-PAGE-COUNT, SCANNER-RETRIEVE-SCANLINE,
SCANNER-MOTOR-CONTROL, COPIER-ADF-PAGE-COUNT, COPIER-
PRINT-PAGE-COUNT, TOTAL-ENGINE-PAGE-COUNT, PRINT-ENGINE-
JAM-COUNT, PRINT-ENGINE-MISPICK-COUNT, CLEAR-NVRAM"
::= { settings-system 9 }
fuser-pressure-release OBJECT-TYPE
SYNTAX INTEGER {
eDisengage(1)
}
ACCESS write-only
STATUS optional
DESCRIPTION "This object is used to disengage the pressure on the fuser to
prevent roller marks on the fuser, which can occur when the
pressure is engaged for long periods of time.
Additional information:
This object is used to disengage the pressure on the
fuser to prevent roller marks on the fuser, which can occur when
the pressure is engaged for long periods of time."
::= { settings-system 53 }
device-configure-generic-language-prompt OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This object is used to determine whether to prompt the user to
enter the appropriate language.
Additional information:
This object is used to determine whether to
prompt the user to enter the appropriate language
at boot."
::= { device-configure 10 }
device-configure-generic-country-prompt OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION " This object is used to determine whether to prompt the user to
enter the appropriate country at boot.
Additional information:
This object is used to determine whether to
prompt the user to enter the appropriate country
at boot."
::= { device-configure 11 }
device-configure-generic-country OBJECT-TYPE
SYNTAX INTEGER {
eKorea(4),
eIndonesia(5),
eChina(6),
eTaiwan(7),
ePhilippines(8),
eThailand(9),
eSriLanka(10),
eBrazil(12),
eCanada(13),
eMexico(14),
eUnitedStates(15),
eArgentina(16),
eChile(17),
eNewZealand(19),
eIsrael(21),
eAustralia(23),
eIndia(25),
ePakistan(26),
eMalaysia(27),
eHongKong(29),
eSingapore(30),
eUnitedKingdom(31),
eAustria(34),
eNetherlands(35),
eGermany(39),
eDenmark(40),
eSweden(41),
eSouthAfrica(42),
eNorway(43),
eIreland(44),
eBelgium(45),
eFinland(46),
eFrance(47),
eTurkey(48),
eGreece(49),
ePortugal(50),
eItaly(51),
eSpain(55),
ePoland(56),
eBulgaria(57),
eCroatia(58),
eRomania(59),
eSlovakRepublic(60),
eCzechRepublic(61),
eHungary(62),
eRussia(64),
ePeru(70),
eJordan(78),
eLebanon(79),
eSwitzerland(82),
eVietnam(83),
eLuxemberg(85),
eNorthAfrica(86),
eBelarus(66),
eBrunei(33),
eCambodia(94),
eCyprus(95),
eEgypt(67),
eEstonia(54),
eIceland(96),
eLatvia(53),
eLiechtentstein(98),
eLithuania(52),
eMalta(99),
eMorocco(65),
eSaudiArabia(28),
eTunisia(32),
eUAE(88),
eUkraine(63)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Set the location configuration for the device. This affects
parameters that vary per region like the default paper size,
symbol set, supply reorder URL, and fax parameters if
applicable."
::= { device-configure 16 }
control-panel-button-press-delay OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object gives the number of seconds to wait before
simulating the button press when CONTROL-PANEL-BUTTON-PRESS is
next called.
Additional information:
This object gives the number of seconds to wait before
simulating the button press when CONTROL-PANEL-BUTTON-PRESS is
next called."
::= { settings-system 47 }
low-power OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Returns or changes the Auto Low Power sleep value. The device
will go into energy saving Auto Low Power mode after the print
engine has been idle for the number of seconds specified by
this object. Frida supports values of 300 until 14400 seconds.
If the value is invalid then it will return status of
PML_Status_ErrUnsupValue and will not issue command to the
engine.
Additional information:
Returns or changes the Auto Low Power sleep value. The device
will go into energy saving Auto Low Power mode after the print
engine has been idle for the number of seconds specified by
this object. The product supports values of 0 (Off), 60 (1
minute), 900 (15 minutes), 1800 (30 minutes), 3600 (1 hour),
7200 (2 hours), and 14400 (4 hours).
If the value is invalid then it will return a status of
PML_ERROR_INVALID_OR_UNSUPPORTED_VALUE and will not issue
a command to the engine."
::= { settings-system 49 }
control-panel-display-contrast OBJECT-TYPE
SYNTAX INTEGER {
eLightest(1),
eLight(2),
eMedium(3),
eDark(4),
eDarkest(5)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This object returns or sets the display contrast setting if the
control panel has a display and it supports contrast
adjustment. The setting Is stored in NVRAM, so the value is
saved over power cycles.
Additional information:
This object returns or sets the display contrast setting
if the control panel has a display and it supports
contrast adjustment. The setting is stored in NVRAM,
so the value is saved over power cycles."
::= { settings-system 73 }
start-engine-early-warmup OBJECT-TYPE
SYNTAX INTEGER {
eValue1(1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION "This PML object is used by HP SW drivers to signal the printer
that a job is coming, and to start the warm-up process
early.The effect of warming up early will reduce the First Page
Out time.
Additional information:
This PML object is used by HP SW drivers to signal the printer
that a job is coming, and to start the warm-up process
early.The effect of warming up early will reduce the First Page
Out time."
::= { settings-system 99 }
enable-engine-early-warmup OBJECT-TYPE
SYNTAX INTEGER {
eDisable(1),
eEnable(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This PML object is used by HP SW to enable/disable the printer
to send the signal of warm-up process early to engine. The
effect of warming up early will reduce the First Page Out
time.
Additional information:
This PML object is used by HP SW to enable/disable the printer
to send the signal of warm-up process early to engine. The
effect of warming up early will reduce the First Page Out
time."
::= { settings-system 101 }
on-off-line OBJECT-TYPE
SYNTAX INTEGER {
eOnline(1),
eOffline(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION "To bring the PDL processing sub-system on or off line. If the
device is a printer, then the printer does not process print
job data when the printer is off line. PML communication
persists.
Additional information:
The value of this object is eOnline
whenever the printer is in the ready state. This object
will return eOffline only when an alert is active. For
example, the printer will go eOffline if the cover is
open, if the toner cartridge is removed, or if the paper
trays are all empty. It is not possible to change the
state of the printer with this object. "
::= { status-system 5 }
auto-continue OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates if the device will automatically continue after
encountering a continuable error. If AUTO-CONTINUE is set to
eOn, the device will automatically generate continue event to
acknowledge continuable errors. If AUTO-CONTINUE is set to
eOff, then some other continue event will have to acknowledge
the continuable error."
::= { status-system 7 }
install-date OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..14))
ACCESS read-write
STATUS optional
DESCRIPTION "Identifies the date that the device was installed. The format
of the string is 'YYYYMMDDHHmmZ'. Where:
YYYY is the year.
MM is the month (1-12).
DD is the day (1-31).
HH is the hour of the day (0-23).
mm are the minutes (0-59).
'Z' designates Greenwich Mean Time; if 'Z' not specified,
value is local time.
Device POS must specify the conditions for setting this
object.
Additional information:
Identifies the date that the device was installed. The
format of the string is 'YYYYMMDDHHmmZ'. Where:
YYYY is the year.
MM is the month (1-12).
DD is the day (1-31).
HH is the hour of the day (0-23).
mm are the minutes (0-59).
'Z' designates Greenwich Mean Time; if 'Z' not specified,
value is local time.
On Products without a real-time clock this
object has the inital value of 'INVALID'. While in
the invalid state the object may written to. Once the
initial install date has been written a new intall date
can not be written without resetting the object to 'INVALID'.
The behavior on products with real-time clocks is different.
The object is set to the initial real-time clock value, usually
this is '199000300000'. Manufacturing sets the real-time
clock to the correct date and sets the INSTALL-DATE to 'INVALID'.
Then when the customer turns on the printer for the first time
the install date is reset."
::= { status-system 8 }
show-address OBJECT-TYPE
SYNTAX INTEGER {
eAuto(3),
eOff(1)
}
ACCESS read-write
STATUS optional
DESCRIPTION "If this object is set to eAuto, and the device has an IP
address, the IP address of the device will be shown with the
READY message. If this object is set to eOff, the IP address
will not be shown."
::= { display-status 3 }
job-input-auto-continue-timeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The number of seconds the device waits after a job related
continuable error occurs before automatically continuing. An
example job related continuable error is the job requesting a
media size that is not available. After the timeout expires,
the device will continue processing the job as if a continue
event occurred, such as the front panel continue key being
pressed. If the value is -1, the device does not automatically
continue after a job related continuable error occurs. If the
value is 0, the device immediately continues. If the value is
greater than 0, the value represents the timeout value in
seconds."
::= { status-system 35 }
job-input-auto-continue-mode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the device behavior when the desired media is
not currently available.
cCancelJob - The device cancels the job. The device POS
should explain what happens if this item is not the
only item in the collection.
cAutoMediaSizeOverride - The device is allowed to
substitute a different size media.
cAutoMediaNameOverride - The device is allowed to
substitute a different media name.
cUSMediaSizeOverride - The device is allowed to substitute
US media sizes (letter, etc.) for ISO media sizes (A4,
etc.).
cISOMediaSizeOverride - The device is allowed to substitute
ISO media sizes (A4, etc.) for US media sizes (letter,
etc.). "
::= { status-system 36 }
control-panel-button-press OBJECT-TYPE
SYNTAX INTEGER {
eGoButton(1),
eMenuPlusButton(2),
eMenuMinusButton(3),
eCancelJobButton(9),
eBackButton(13),
eNumericButton0(16),
eNumericButton1(17),
eNumericButton2(18),
eNumericButton3(19),
eNumericButton4(20),
eNumericButton5(21),
eNumericButton6(22),
eNumericButton7(23),
eNumericButton8(24),
eNumericButton9(25),
eMenuButton(28),
eAsterickButton(30),
ePoundButton(31),
eCopyLighterDarkerButton(32),
eCopyReduceEnlargeButton(33),
eCopyButton(36),
eStartFaxButton(42),
eFaxPhoneBookButton(44),
ePauseRedialButton(46),
eSpeedDialOneButton(47),
eSpeedDialTwoButton(48),
eSpeedDialThreeButton(49),
eSpeedDialFourButton(50),
eCopyNumCopiesButton(59),
eCopyFeaturesButton(60),
eShiftButton(66),
eFaxMenuButton(67)
}
ACCESS write-only
STATUS optional
DESCRIPTION "Writing this object simulates pressing a button on the control
panel. Reading it will return the last key pressed either on
the control panel or via PML. The device POS will specify which
keys are supported.
Additional information:
Writing this object simulates pressing a
button on the control panel."
::= { status-system 60 }
device-mac-address OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "The device's MAC address.
Additional information:
The device's MAC address."
::= { status-system 120 }
extended-print-modes-modified OBJECT-TYPE
SYNTAX INTEGER {
eYes(1),
eNo(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION "This object allows the user to view whether the extended print
modes have been modified from their default settings.
Additional information:
This object allows the user to view whether the extended print
modes have been modified from their default settings."
::= { status-system 121 }
model-number OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Identifies the device model number as listed in the HP
corporate price list (e.g. C2121A for DeskJet 500C). The string
is as specific as possible. Products should note in POS if the
model number on the CPL changes but the device reports the
previous model number. If the model number changes based on the
installed options, the POS should indicate if only the base
model number is returned, or if the device senses the installed
options and returns the correct model number. If possible,
encode the model number in a symbol set (like Roman-8) that
matches the ASCII character set and limit the characters used
to ASCII characters.
Additional information:
Identifies the device model number as listed in the HP
corporate price list (e.g. C2121A for DeskJet 500C)."
::= { id 1 }
model-name OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Identifies the device model name (e.g. ''DeskJet 1200C''). The
string is as specific as possible. Capitalization and spacing
should match family naming conventions. Products should note in
POS if the model name on the HP corporate price list changes
but the device reports the previous device name. If the model
name changes based on the installed options, the POS should
indicate if only the base model name is returned, or if the
device senses the installed options and returns the correct
model name. If possible, encode the model name in a symbol set
(like Roman-8) that matches the ASCII character set and limit
the characters used to ASCII characters.
Additional information:
The value of this object changes based on the
installed options.
Since the value of this object is frequently used in
displaying a list of printers, it is kept relatively
short in case systems have limited width for their
display area."
::= { id 2 }
serial-number OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..10))
ACCESS read-write
STATUS optional
DESCRIPTION "Identifies the serial number for the device. If the
SERIAL-NUMBER object is set by the user, then setting the
object does not need to be protected. If the SERIAL-NUMBER
object is set at the factory, then the SERVICE-PASSWORD object
must be set correctly before the SERIAL-NUMBER object is
writable. If this is a writable object, the POS should indicate
the maximum supported string length. If possible, encode the
serial number in a symbol set (like Roman-8) that matches the
ASCII character set and limit the characters used to ASCII
characters.
Additional information:
This value is initially set to the default
value of XXXXXXXXXX."
::= { id 3 }
fw-rom-datecode OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Identifies the base system firmware date code. The date code
will be encoded in the yyyymmdd format. There may be several
versions of the base system firmware. The date code associated
with the version of the base system firmware that is being used
is reported. There may be other date code objects for other
specific modules such as fonts, localization modules, etc.;
these other datecode objects are device specific."
::= { id 5 }
device-name OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "User defined device name. The POS should indicate the maximum
supported string length. If the user entered string is too
long, the device will store as much as possible and will return
the <OKNearestLegal ValueSubstituted>.Additional information:
The maximum supported string length is 32
characters. If the user entered string is too long, the
device will store the first 32 characters and will
return the <noError> status."
::= { id 10 }
asset-number OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..8))
ACCESS read-write
STATUS optional
DESCRIPTION "User defined asset number. The POS should indicate the maximum
supported string length. If the user entered string is too
long, the device will store as much as possible and will return
the <OKNearestLegal ValueSubstituted>.Additional information:
The maximum supported string length is 8
characters. If the user entered string is too long, the
device will store the first 8 characters and will return
the <noError> status."
::= { id 12 }
simm1-type OBJECT-TYPE
SYNTAX INTEGER {
eEmpty(1),
eUnknown(2),
eUnSupported(3),
eReadOnlyMemory(4),
eVolatileRandomAccessMemory(5),
eRamRom(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Returns an indication of the type of option installed in SIMM
slot 1.
eEmpty means the device did not detect any option installed
in the interface slot.
eUnknown means the device doesn't recognize the installed
option.
eUnSupported means the device recognizes the installed
option, but does not support the option.
eReadOnlyMemory means the installed option contains ROM
Ics.
eVolatileRandomAccessMemory means the installed option
contains RAM ICs that loose data when the power is
turned off.
eNonVolatileRandomAccessMemory means that the installed
option contains RAM ICs that do not loose data when the
power is turned off.
eFlashMemory means that the installed option contains a
type of non-volatile RAM that needs to be erased before
it can be written.
eDiskDrive means the installed option contains a disk
drive.
eRamRom means the installed option contains both volatile
random access memory and read only memory.
eInputPHD means the installed option is an input paper
handling device.
eOutputPHD means the installed option is an output paper
handling device. eIOCard means the installed option is
an I/O card.
eVolatileRAMOnBoardMemory means the installed option
contains on board RAM ICs that loose data when the
power is turned off.
Additional information:
This object is used to describe DIMMs
instead of SIMMs on the product. eRamRom is
used to denote a combo dimm."
::= { simm1 4 }
simm1-capacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Returns an indication of the capacity of the SIMM installed in
SIMM slot 1. The capacity is dependent on the type of option,
as indicated by the SIMM1-TYPE object. This object has no
meaning if the installed option type is eUnknown or
eReadOnlyMemory. This object contains the size, in bytes, if
the installed option type is eVolatileRandomAccessMemory,
eNonVolatileRandomAccessMemory, eFlashMemory, or eDiskDrive. If
the type of the installed option is eRamRom, this object
contains the size, in bytes, of the random access memory. If
the type of the installed option is eInputPHD, the capacity
indicates the number of input trays supported by the installed
option. If the type of the installed option is eOutputPHD, the
capacity indicates the number of output bins supported by the
installed option. If the type of the installed option is
eIOCard, the capacity indicates the number of logical I/O ports
supported by the I/O card.
Additional information:
Returns an indication of the capacity of
the installed option in bytes. This object is not
supported unless the SIMM1-TYPE type is
eVolatileRandomAccessMemory or eRamRom. For eRamRom
only the size of the Ram portion of the simm (dimm) is
returned."
::= { simm1 5 }
self-test OBJECT-TYPE
SYNTAX INTEGER {
eNotInASelfTest(1),
eNonDestructiveSelfTest(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Writing this object allows a device self test to be started.
Reading this object provides an indication what self-test is
currently executing, if any. Actual self-test operation is
device specific. A self test may not be allowed at any
arbitrary time. If the device supports the requested self test,
but can not start the execution of the self test when
requested, the device will respond with
<genErr>. If a non-destructive self
test is being started, the device will generate a response
before the self test is completed. RECOMMENDATION: If the
device is ready (i.e. the NOT-READY-PRINTER object does not
contain any items, except maybe being off-line) and is idle
(i.e. the NOT-IDLE object does not contain any items), this
request should always succeed. This provides a mechanism for
driver writers to always determine if the action will succeed
or not.
Additional information:
The eNonDestructiveSelfTest performs
limited testing on the printer and its attached paper
handling devices. After the self-test is complete a
configuration page is printed. The recommended way to
cause a configuration page to be printed is to use the
PRINT-INTERNAL-PAGE object. A continuous self test
cannot be started or terminated using this OID.
When the printer is idle, setting this object to
eNonDestructiveSelfTest results in a status of <noError> and
a value of eNonDestructiveSelfTest being returned. If
the printer is not idle (whether printing an external
job, printing an internal page or running self test), a
status of <genErr> status will
be returned with a value of eNotInASelfTest.
When the printer is idle, setting this object to
eNonDestructiveSelfTest causes the configuration page to
be formatted and put in the printer's print queue.
Attempting to set this object before the configuration
page has completed being formatted and printed will
cause <genErr> status to be
returned with a value of eNotInASelfTest.
After the configuration page is in the queue, a get on
this object will return a value of eNotInASelfTest.
Setting the value to eNotInASelfTest is not supported on
the product. Once the test has started, it
will finish printing.
Likewise, if the PRINT-INTERNAL-PAGE object is set to a
valid value and that page has not printed when this
object is set to eNonDestructiveSelfTest, a status of
<genErr> status with a value of
eNotInASelfTest will be returned until the internal page
has printed."
::= { test 1 }
print-internal-page OBJECT-TYPE
SYNTAX INTEGER {
eNotPrintingAnInternalPage(1),
ePrintingAnUnknownInternalPage(2),
eDeviceDemoPage1ConfigurationPage(3),
eDeviceDemoPage2(4),
eDeviceDemoPage7MenuMap(9),
eDeviceUsagePage(10),
eServicePage(13),
eSuppliesPage(101),
eDeviceCleaningPage(253),
ePCLFontList1(350),
ePCLXLFontList1(353),
ePostScriptFontList1(450),
eNetworkConfigPage(1200),
eFaxActivityLogPage(1304)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Writing this object to a value other than
eNotPrintingAnInternalPage causes the device to attempt to
print an internally generated page. Reading this object
provides an indication what internally generated page is
currently being printed, if any. The actual page is device
specific. Some devices may support continuously printing an
internally generated page. Setting this object to
eNotPrintingAnInternalPage terminates continuously printing
internally generated pages. An internally generated page may
not be allowed to be printed at any arbitrary time; under what
conditions it will succeed or fail is device specific. If the
device supports the requested page, but can not start printing
the page when requested, the device will respond with
<genErr>. RECOMMENDATION: If the
device is ready (i.e. the NOT-READY-PRINTER object does not
contain any items, except maybe being off-line) and is idle
(i.e. the NOT-IDLE object does not contain any items), this
request should always succeed. This provides a mechanism for
driver writers to always determine if the action will succeed
or not.
Additional information:
eDeviceDemoPage2 is the printer demo page.
ePCLFontList1 is the PCL typeface list,
ePostScriptFontList1 is the PostScript font list, and
eDeviceDemoPage1ConfigurationPage is the selftest page.
The product does not support continuously
printing a demo page.
The printer will queue requests if it is currently busy.
When this object is set to a valid value and the printer
is idle, the status returned is <noError> and the value
returned is ePrintingAnUnknownInternalPage.
Setting this object to a valid value causes the desired
page to be formatted and put in the printer's print
queue. While the page is being formatted, and the
printer remains in a testing state, a get on this object
will return the value ePrintingAnUnknownInternalPage.
The return value will be eNotPrintingAnInternal page if
the printer is not in a testing state, and the internal
page is done being formatted.
The user will not be able to set
eNotPrintingAnInternalPage or
ePrintingAnUnknownInternalPage, and the return status
will be <badValue> with a return
value of eNotPrintingAnInternalPage.
ePostScriptFontList1 and ePCLFontList1 will not be
valid values unless postscript and PCL, respectively,
are installed in the printer. If postscript (PCL)
is not installed and the user attempts to set
ePostScriptFontList1 (ePCLFontList1), the return status
will be <badValue> with a return
value of eNotPrintingAnInternalPage.
Setting through DMCMD will cause a 15 second delay in
printing."
::= { test 2 }
job-info-change-id OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(16))
ACCESS read-only
STATUS optional
DESCRIPTION "Returns the current value of an object in the job-info sub-tree
whose value has changed. Define the object identifier for the
object whose value has changed as
job-info.required-field.optional-field.job-id. job-info
represents the OID prefix of all objects in the job-info
sub-tree. Required-field represents the OID field value that
follows the job-info prefix. Since some objects in the job-info
sub-tree have two OID fields between the job-info prefix and
the job-id, the optional-field represents the OID field between
the required-field and the job-id field, if present. Using this
definition, the format for the JOB-INFO-CHANGE-ID binary value
can be described as follows:
Bytes 0-3 : required-field
Bytes 4-7 : optional-field, or all zeros if there
is no optional field
Bytes 8-11: Job ID.
Bytes 12-n : The value of the object job-info.
required-field.optional-field.job-id.
All multi-byte values stored in Motorola (big-endian) format,
where the most significant byte occurs first.
Additional information:
The product will use this object
to report changes of the job-info-pages-printed and
job-info-state objects. The required-field (bytes 0
through 3) will designate whether the change to be
reported involves the pages printed (13) or job state
(15). The optional-field (bytes 4 through 7) will
always be zeroes. The value-field (bytes 12 through 15)
will contain the new value for pages printed or job
state cast to a 32-bit integer."
::= { settings-job 3 }
current-job-parsing-id OBJECT-TYPE
SYNTAX INTEGER(-1..32767)
ACCESS read-only
STATUS optional
DESCRIPTION "Contains the printer assigned job identification for the job
currently being processed by the processing PDL sub-system. The
job ID is a monotonically increasing number. The job ID may be
reset to zero at power-up and may roll over to zero after
reaching some maximum value.
Additional information:
A value of -1 is returned when the printer
is not parsing a job.
When data for a new job is detected, this object is
updated (the job may or may not turn out to be a Null
Job). (A job is considered to be a 'null job' if it has
no name or job attribute, causes no pages to be printed,
and consumes MIN_JOB_SIZE (9) or fewer bytes.) See the
Job Boundary ERS for details on what constitutes a job
boundary.
Some job-info- objects are created when the first data
bytes are received. If the printer determines that the
job is a Null Job, the job-info- objects related to the
Null Job are deleted. The product retains
the job-info- objects for the MAX_JOBS_IN_LIST (12) most
recent jobs that are not Null Jobs.
The first job received after power-up will have job ID 1,
and the job ID will increment to 32767 before rolling
to zero. To distinguish whether a power cycle or a
rollover causes a reduction in the job ID value, the
object prtGeneralConfigChanges can be watched and if it
increments at the same time as the drop is observed in
the value of CURRENT-JOB-PARSING-ID, then a power cycle
is the most likely cause."
::= { job-being-parsed 1 }
job-info-io-source OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates which I/O source, the print job was received over.
The value maps to port numbering scheme supported in the
DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree.
Additional information:
The product does not
support the DEVICE/SOURCE-SUBSYSTEM/IO/PORTS sub-tree."
::= { job-info 11 }
job-info-outbins-used OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates which output bins this job has delivered printed
pages to. The last OID field for this dynamic object contains
the job ID.
Additional information:
The product has only 1 output bin.
cOutbin1 is the top/face-down bin."
::= { job-info 20 }
error1-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 1
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
This item contains the engine page count
when the error occurred.
If there is currently no error entry for this object, a
'0' will be returned. If ERROR1-CODE object also
returns '0', then an error has not yet been logged for
this object
See ERROR1-CODE for an explanation of the order used for
storing errors."
::= { error1 1 }
error1-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
Returns a device specific error code. If
the error code returned is '0', then the printer has not
yet logged an error for this object. When the maximum
number of errors is reached (10 on the
product), and a new error occurs, the error in
ERROR1-CODE will be replaced by the one in ERROR2-CODE,
and so on until the last error object will be given the
value of the new error.
The error category is returned in the upper 16 bits,
either 79 (for service) or 0 (for support). The lower
16 bits encodes the specific error. If an error is not
a 79 service error, the value of this object is the PJL
USTATUS code. If it is a 79 service error, the lower 16
bits contain the PJL USTATUS code.
The types of errors reported for the product are:
49 Service Error
50-67 Service Error
69 Service Error
70-72 Service Error
79 Service Errors
Access Error
Address Error
ASIC fault
Asserts
Bad Beam Detect
Bad E-Label
Bad Fan
Bad Fuser
Bad Malfunction
Bad MIO
Bad Scanner Motor
Data Communication Error
Engine Communication Error
Format Error
Genunine HP Supply Installed
Illegal Instruction
Insufficient Memory
Invalid Personality
Laser Malfunction
MIO Buffer Overflow
MIO Connection Break
Missing E-Label
Non-HP Supply Detected
NVRAM Error
NVRAM Service Error
Parallel Buffer Overflow
Print Page Punt
Priviledge Violation
Trace Fault
Unimplemented Line-a Opcode
Unimplemented Line-f Opcode
Uninitialized Interrupt"
::= { error1 2 }
error2-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 2
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error2 1 }
error2-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error2 2 }
error3-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 3
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error3 1 }
error3-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error3 2 }
error4-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 4
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error4 1 }
error4-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error4 2 }
error5-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 5
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error5 1 }
error5-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error5 2 }
error6-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 6
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error6 1 }
error6-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error6 2 }
error7-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 7
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error7 1 }
error7-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error7 2 }
error8-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 8
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error8 1 }
error8-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error8 2 }
error9-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 9
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error9 1 }
error9-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error9 2 }
error10-time-stamp OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains some sort of time stamp indicating when error 10
occurred. Example time stamps include the actual time the error
occurred (in seconds since Jan. 1, 1970), and the total engine
page count. The device POS documents the meaning of the time
stamp.
Additional information:
See ERROR1-TIME-STAMP."
::= { error10 1 }
error10-code OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Contains a device specific error code. Each device POS should
list what errors are logged to the error log and the meaning of
each supported error code value.
Additional information:
See ERROR1-CODE."
::= { error10 2 }
firmware-download-version OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "This object will return a string value representing the current
revision of firmware that the printer is operating with. This
is used to determine if code needs to be upgraded when an
firmware bundle comes in, in an upgrade job.
Additional information:
This object will return a string value representing the current
revision of firmware that the printer is operating with. This
is used to determine if code needs to be upgraded when an
firmware bundle comes in, in an upgrade job."
::= { firmware-download 7 }
io-timeout OBJECT-TYPE
SYNTAX INTEGER(5..7200)
ACCESS read-write
STATUS optional
DESCRIPTION "The amount of time, in seconds, to wait for more print job data
to be received before an I/O timeout occurs. The I/O channel
being timed is the I/O channel that received the data
associated with the current print job. If an I/O timeout
occurs, the PDL processing sub-system assumes all the data
associated with the current print job has been received, and
processes the end of job in a PDL specific manner. The POS
specifies the supported values.
Additional information:
If an I/O timeout occurs,the PDL processing
sub-system will consider it an end of job condition only
if there is data from another I/O subsystem waiting to be
processed.
The supported values are 5 to 7200 seconds. Setting to a
value outside the supported range returns
<badValue> status."
::= { settings-io 1 }
io-switch OBJECT-TYPE
SYNTAX INTEGER {
eYes(1)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates if the device will switch between I/O channels when a
job boundary is encountered and print job data is available on
another I/O channel."
::= { settings-io 2 }
default-copies OBJECT-TYPE
SYNTAX INTEGER(1..999)
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes default copies. Default copies is the
default values used by the PDL to control the number of copies
of each page in the print job that are printed. The print job
can override this value. The list of supported values should be
documented in the device POS.
Additional information:
The supported values are 1 through 999.
Setting to an unsupported value causes the printer to
substitute in a snap value and to return
<noError> status.
The snaps are as follows:
<1 snaps to
>999 snaps to 999"
::= { settings-pdl 4 }
default-vertical-black-resolution OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the value of the default vertical black
resolution. The units are dots per inch.
Additional information:
In the product, changing this OID
also causes DEFAULT-HORIZONTAL-BLACK RESOLUTION to
change. DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
same. The supported values are 300, 600, and 1200.
Setting to an unsupported value causes the printer to
substitute in a snap value and to return
<noError> status.
The snap values are as follows:
<450 will snap to 300
>=450 and <900 will snap to 600
>=900 will snap to 1200"
::= { settings-pdl 8 }
default-horizontal-black-resolution OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the value of the default horizontal black
resolution. The units are dots per inch.
Additional information:
In the product, changing this OID
also causes DEFAULT-VERTICAL-BLACK RESOLUTION to change.
DEFAULT-HORIZONTAL-BLACK-RESOLUTION and
DEFAULT-VERTICAL-BLACK-RESOLUTION must always be the
same. The supported values are 300, 600 and 1200.
Setting to an unsupported value causes the printer to
substitute in a snap value and to return
<noError> status.
The snap values are as follows:
<450 snaps to 300
>=450 and <900 snaps to 600
>=900 snaps to 1200"
::= { settings-pdl 9 }
default-lines-per-page OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the default number of lines per page. The
POS indicates the supported values. An unsupported value causes
the printer to use the closest supported value, causing the
printer to return the <noError>.
Additional information:
The supported values in the product
are 5 to 128. Setting to an unsupported value
causes the printer to substitute in a snap value and to
return <noError> status.
The snap values are as follows:
<5 snaps to 5
>128 snaps to 128"
::= { settings-pdl 11 }
default-vmi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the default vertical motion index. The unit
of measure for VMI is centipoints per line. The POS indicates
the supported values. An unsupported value causes the printer
to use the closest supported value, causing the printer to
return <noError>.
Additional information:
Setting this object may cause
DEFAULT-LINES-PER-PAGE to change."
::= { settings-pdl 12 }
default-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eFoolscap(10),
eROC16K(17),
eISOandJISA4(26),
eISOandJISA5(25),
eISOandJISA6(24),
eROC16K195X270(34),
eJISB5(45),
eISOB5(65),
eJapanesePostcardSingle(71),
eJapanesePostcardDouble(72),
eMonarch(80),
eCommercial10(81),
eROC16K184X260(89),
eInternationalDL(90),
eInternationalC5(91),
eInternationalB5(100),
eCustom(101)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This indicates the default media size. A write of an
unsupported value causes an <ErrorInvalidOrUnsupported Value>. Complete list of supported media sizes along with their
dimensions are listed in the ''Media Size Table'' near the end
of this document. (for a full list of media size enums see the
end of this file) "
::= { settings-pdl 13 }
cold-reset-media-size OBJECT-TYPE
SYNTAX INTEGER {
eUSLetter(2),
eISOandJISA4(26)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the media size that is used as the
DEFAULT-MEDIA-SIZE when a cold reset occurs."
::= { settings-pdl 19 }
default-media-name OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the media name that is used until the media
name is changed by a print job command.
Additional information:
This string must be one of the MEDIAn-NAME
objects, except it cannot be set to ANY.
The value of this object is saved across
a power cycle."
::= { settings-pdl 22 }
reprint OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2),
eAuto(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the reprint (jam recovery) setting. If eOn,
then the device will reprint pages jammed pages. If eOff, the
device will not attempt to reprint jammed pages. If eAuto, a
device dependent algorithm (which should be documented in the
POS) will be used to determine if the page gets reprinted. This
object controls all PDLs, unless a specific PDL supports its
own reprint control mechanism. To date, only PostScript has a
PDL reprint control mechanism.
Additional information:
Setting this object when the printer is not
idle, may cause a status of <noError> to be returned, but
the new value will not take effect until a job boundary
is reached. If a get is done on object before the job
boundary is reached, the value last set will be
returned.
When the value is set to eOff, pages will not be stored
in the printer, and in the event of a paper jam, will
have to be reprinted. When the value is set to eOn,
pages will be stored until delivery, therefore, in the
event of a paper jam, the page will be reprinted.
When the value is set to eAuto, the printer will behave
as though it is eOff when there is less than seven
megabytes of memory installed in the printer. When
additional memory is installed, to total at least seven
megabytes of RAM, the setting of eAuto will behave as
though it was set to eOn."
::= { settings-pdl 36 }
wide-a4 OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the wide A4 logical page size setting. If
eOn, then the margins/printable area of A4 paper will be
changed to allow 80 10-pitch characters to be printed on a
single line. If eOff then the industry standard A4 logical page
size is used."
::= { settings-pdl 37 }
dark-courier OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the dark Courier setting. If eOn, then the
Courier font used will approximate the same darkness as the
LaserJet III printer. If eOff, then the Courier font used will
approximate the same darkness as the LaserJet 4 printer."
::= { settings-pdl 38 }
default-bits-per-pixel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Controls the number of levels used (per pixel) when printing
grayscale or color images."
::= { settings-pdl 39 }
pcl-total-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Total number of PCL pages printed by the device."
::= { pdl-pcl 5 }
pcl-default-font-height OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the default PCL height. Height is an
approximate measure of the body of the type in centipoints. A
centipoint is 1/7200 inch. Height applies only to proportional
fonts. Point size, in points, can be converted to font height,
in centipoints, by multiplying the point size by 100. The POS
indicates the supported values. An unsupported value causes the
printer to use the closest supported value, causing the printer
to return <noError>. ''Closest'' means
the smallest absolute difference.
Additional information:
This object refers to the font point size
with 400 representing the smallest settable font (4) and
99975 representing the largest settable font (999.75).
The default of 1200 is a font point size of 12.
Supported values range from 400 to 99975. Setting to an
unsupported value causes the printer to substitute in a
snap value and to return
<noError> status.
The snap values are as follows:
<=400 snaps to 400
>=99975 snaps to 99975
Fonts are settable to the nearest quarter point size
(i.e. 10, 10.25, 10.50, 10.75). Unsupported values in
the range 401 to 99974 snap DOWN to the previous
supported value (i.e 25293 snaps to 25275 or 75038 snaps
to 75025)."
::= { pdl-pcl 13 }
pcl-default-font-source OBJECT-TYPE
SYNTAX INTEGER {
eInternal(1),
ePermanentSoft(2),
eRomSimm1(10)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the value of the default font source
variable in NVRAM."
::= { pdl-pcl 14 }
pcl-default-font-number OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the value of the default font number
variable in NVRAM. Writing an unsupported value causes the
printer to generate an <badValue>.
Additional information:
Valid numbers or 0 - 255, but only font
numbers that are included in the PCL FONT LIST are
selectable."
::= { pdl-pcl 15 }
pcl-default-font-width OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the default PCL font width. Width is
expressed as the width of a character in centipoints. A
centipoint is 1/7200 inch. Width applies only to fixed space
fonts. Pitch, in character per inch, can be converted to font
width, in centipoints, by dividing 7200 by the pitch. The POS
indicates the supported values. An unsupported value causes the
printer to use the closest supported value, causing the printer
to return <noError>. ''Closest'' means
the smallest absolute difference.
Additional information:
Setting to an unsupported value causes the
printer to substitue in a snap value (listed below) and
return <noError> status.
The snap values for pitch are as follow:
<=44 snaps to 44
>=9999 snaps to 9999
Unsupported values in the range 44 - 9999 (.44 - 99.99)
snap DOWN to the next supported value."
::= { pdl-pcl 16 }
postscript-total-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Total number of PostScript pages printed by the device."
::= { pdl-postscript 5 }
postscript-print-errors OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the value of the print PostScript errors
setting. If eOn, PostScript prints an error page showing the
error encountered and the stack at the time of the error.
Additional information:
Returns or changes the value of the print PostScript errors
setting. If eOn, PostScript prints an error page showing the
error encountered and the stack at the time of the error."
::= { pdl-postscript 11 }
pclxl-total-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Total number of PCLXL pages printed by the device."
::= { pdl-pclxl 1 }
pjl-password OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Returns PJL password, if the password is not set (zero). If the
password is set, then attempting to retrieve the password
causes an <genErr> to occur and will return
the <NullValue>."
::= { pjl 1 }
default-duplex-mode OBJECT-TYPE
SYNTAX INTEGER {
eSimplex(1),
eDuplexVerticalBinding(2),
eDuplexHorizontalBinding(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the duplex printing mode. Duplex printing is
when printing occurs on both sides of a sheet of media.
Vertical binding is also called long edge binding or book
binding. Horizontal binding is also called short edge binding
or calendar binding.
Additional information:
Returns or sets the duplex printing mode. Duplex printing is
when printing occurs on both sides of a sheet of media.
Vertical binding is also called long edge binding or book
binding. Horizontal binding is also called short edge binding
or calendar binding."
::= { settings-prt-eng 4 }
print-density OBJECT-TYPE
SYNTAX INTEGER(1..5)
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the print density setting. Print density is the
instantaneous amount of marking agent applied to the paper
while printing. A value of zero has the lowest print density,
yielding a lighter page. A value of 10 has the highest print
density, yielding a darker page. Each POS should document what
values in the 0 to 10 range are supported.
Additional information:
When this value is written, the page
pipeline will be flushed (all pages being printed are
completed, no new ones are started), the new density
setting is set and printing resumes. The acutal change
in print density may be gradual over several pages.
The supported values are 1 through 5. Setting to an
unsupported value causes the printer to substitue in a
a snap value and to return <noError>
status.
The snap values are as follows:
<1 snaps to 1
>5 snaps to 5."
::= { settings-prt-eng 5 }
invalid-personality-reports-enabled OBJECT-TYPE
SYNTAX INTEGER {
eDisabled(1),
eEnabled(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Read or configure wether invalid personality reports are
enabled or disabled for a product."
::= { settings-prt-eng 18 }
fast-first-page-out OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Return or set the value of the fast first page out setting.
Additional information:
Return or set the value of the fast first page out setting."
::= { settings-prt-eng 19 }
supplies-replace-action-at-setting OBJECT-TYPE
SYNTAX INTEGER {
eStopAtOut(2),
eOverrideAtOut(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This object can be used to change the setting of menu item
REPLACE SUPPLIES. The behavior of the printer when a supply
reaches low changes in accordance with the setting of this PML
Object. If the option eStopAtLow is selected printer will stop
when a supply reaches LOW. If the option eStopAtOut is selected
then printer will stop when a supply reaches OUT. If the
options eStopAtMaxLife (supported only on Mono products) is
selected, the printer will continue past supply OUT. If the
option eOverrideAtOut or eOverrideAtOut2 (supported only on
Color products) is selected then printer will continue past OUT
in override mode. This option is not writeable. That is using
this PML object the setting could be changed to any option
other than eOverrideAtOut and eOverrideAtOut2.
Additional information:
This object can be used to change the Supply Out Override
Enabled Setting. The behavior of the printer when a supply
reaches out changes in accordance with the setting of this PML
Object. If the option eStopAtOut is selected then printer will
stop when a supply reaches OUT. If the option eOverrideAtOut is
selected then the printer will continue past OUT in override
mode."
::= { settings-prt-eng 25 }
supplies-at-very-low-setting OBJECT-TYPE
SYNTAX INTEGER {
eStopAtOut(2),
eOverrideAtOut(4),
ePromptAtOut(6),
ePrintBlack(7)
}
ACCESS read-write
STATUS optional
DESCRIPTION "This object can be used to change the setting of menu item AT
VERY LOW. The behavior of the printer when a supply reaches low
changes in accordance with the setting of this PML Object. If
the option eStopAtOut is selected then printer will stop when a
supply reaches Estimated End of Life (EEOL). If the option
eOverrideAtOut is selected then printer will continue past EEOL
in override mode. If the option eOverrideAtOut is selected then
printer will continue past EEOL in override mode. If the option
ePromptAtOut is selected then printer will ask the user if they
wish to continue printing past EEOL in override mode. If the
option eAutoContinueBlack is selected then printer will
continue printing in mono past EEOL. This may be subject to
page limits. (Color only) NOTE: This object replaces
SUPPLIES-REPLACE-ACTION-AT-SETTING"
::= { settings-prt-eng 38 }
total-engine-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Total number of pages printed by the device. POS indicates if
the total engine page count is kept in NVRAM, and the maximum
supported value before the page count rolls over to zero.
Additional information:
This object is stored in NVRAM. The maximum value of
this count is 1000000 before it rolls over to zero."
::= { status-prt-eng 5 }
print-engine-jam-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Total number of pages jammed in the print engine's life time.
The POS indicates if the total jam count is kept in NVRAM and
the maximum supported value before the jam count rolls over to
zero.
Additional information:
This object is stored in NVRAM. The maximum value of
this count is 65000 before it rolls over to zero."
::= { status-prt-eng 34 }
print-engine-mispick-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Total number of pages mispicked in the print engine's life
time. The POS indicates if the total mispick count is kept in
NVRAM and the maximum supported value before the mispick count
rolls over to zero.
Additional information:
This object is stored in NVRAM. The maximum value of
this count is 65000 before it rolls over to zero."
::= { status-prt-eng 35 }
supply-out-device-state OBJECT-TYPE
SYNTAX INTEGER {
eNoSupplyOut(1),
eOffline(2),
eSupplyOutOverride(3)
}
ACCESS read-only
STATUS optional
DESCRIPTION "This PML object indicates the current behavior of the device if
one or more supplies have reached out. If no supply has reached
out, the value of this PML object is eNoSupplyOut. If one or
more supplies have reached out, the value of this PML object
will indicate if the printer is online and if so what mode is
being used to continue printing.
Additional information:
This PML object indicates the current behavior of the device if
one or more supplies have reached out. If no supply has reached
out, the value of this PML object is eNoSupplyOut. If one or
more supplies have reached out, the value of this PML object
will indicate if the printer is online and if so what mode is
being used to continue printing. Note: Hummingbird will never
return eMonochromePrintingAfterColorCartridgeOut, as it does not
support MPACCO."
::= { status-prt-eng 49 }
duplex-page-count OBJECT-TYPE
SYNTAX INTEGER(0..1000000)
ACCESS read-write
STATUS optional
DESCRIPTION "Total number of sheets of media that have been duplex printed.
A sheet is counted if it travels through the duplex page path,
regardless of whether or not marks are made on the page. The
POS will indicate if the value is kept in NVRAM.
Additional information:
Total number of sheets of media that have been duplex printed.
A sheet is counted if it travels through the duplex page path,
regardless of whether or not marks are made on the page.
This object is stored in NVRAM. The maximum value of
this count is 1000000 before it rolls over to zero."
::= { status-prt-eng 22 }
print-engine-revision OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Print engine revision string.
Additional information:
Print engine revision string."
::= { status-prt-eng 26 }
mp-tray OBJECT-TYPE
SYNTAX INTEGER {
eManual(1),
eCassette(2),
eFirst(3)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the value of the multi-purpose (MP) tray
configuration variable. The MP tray can be configured to
operate as an additional input tray (eCassette), a manual feed
slot (eManual), or in a manner compatible with the LaserJet III
manual feed slot (eFirst). If configured for eFirst, if media
is present in the MP tray, that media is used (assuming the
size matches and the print job didn't specify another tray)
until the MP tray is empty.
Additional information:
Returns or changes the value of the multi-purpose (MP) tray
configuration variable. The MP tray can be configured to
operate as an additional input tray (eCassette), a manual feed
slot (eManual), or in a manner compatible with the LaserJet III
manual feed slot (eFirst). If configured for eFirst, if media
is present in the MP tray, that media is used (assuming the
size matches and the print job didn't specify another tray)
until the MP tray is empty."
::= { settings-intray 5 }
tray-lock OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the list of locked input trays. The printer
only pulls media from a locked input tray when the input tray
is specifically requested by the print job.
Additional information:
Returns or changes the list of locked input trays. The printer
only pulls media from a locked input tray when the input tray
is specifically requested by the print job."
::= { settings-intray 6 }
custom-paper-dim-unit OBJECT-TYPE
SYNTAX INTEGER {
eTenThousandthsOfInches(3),
eMicrometers(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION "The units of measure used to specify the width and height of
the printer's custom paper. The unit of measure of
eTenThousandthsOfInches is 0.0001 inches.
Additional information:
The only valid values for this object are
eTenThousandthsOfInches (3), and eMicrometers (4). The
data for this object is stored in NVRAM."
::= { settings-intray 7 }
custom-paper-feed-dim OBJECT-TYPE
SYNTAX INTEGER(50000..140000)
ACCESS read-write
STATUS optional
DESCRIPTION "Sets the printer's custom paper dimension in the feed direction
(direction parallel to the direction of paper feeding). The
value for this object is specified in micrometers or
tenthousandths of an inch, depending upon the value of
CUSTOM-PAPER-DIM-UNIT. The valid range is engine-dependent and
should be documented in the POS for each product.
Additional information:
The valid range is 50000 to 140000 if
CUSTOM-PAPER_DIM_UNIT is eTenThousandthsOfInches or 127000 to
355600 if CUSTOM-PAPER-DIM-UNIT is ePmicrometers. Attempts
to set this object outside the valid range will result in a
return value of ERROR_INVALID_OR_UNSUPPORTED_VALUE."
::= { settings-intray 8 }
custom-paper-xfeed-dim OBJECT-TYPE
SYNTAX INTEGER(30000..85000)
ACCESS read-write
STATUS optional
DESCRIPTION "Sets the printer's custom paper dimension in the cross-feed
direction (direction ninety degrees relative to the direction
of paper feeding). The value for this object is specified in
micrometers or tenthousandths of an inch, depending upon the
value of CUSTOM-PAPER-DIM-UNIT. The valid range is
engine-dependent and should be documented in the POS for each
product.
Additional information:
The valid range for the product
is 30000 to 85000 if CUSTOM-PAPER-DIM-UNIT is
eTenThousandthsOfInches or 76200 to 215900 if
CUSTOM-PAPER-DIM-UNIT is ePmicrometers. Attempts to set
this object outside the valid range will result in a
return value of <badValue>."
::= { settings-intray 9 }
tray1-media-size-loaded OBJECT-TYPE
SYNTAX INTEGER {
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eFoolscap(10),
eROC16K(17),
eISOandJISA5(25),
eISOandJISA4(26),
eISOandJISA6(24),
eROC16K195X270(34),
eJISB5(45),
eJapanesePostcardSingle(71),
eJapanesePostcardDouble(72),
eMonarch(80),
eCommercial10(81),
eROC16K184X260(89),
eInternationalDL(90),
eInternationalC5(91),
eInternationalB5(100),
eCustom(101),
eAnySize(32765)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns the media size that is currently configuredconfigured
in tray #1. This object can be set to indicate the media size
currently loaded, if the printer supports input trays that can
not sense the media size. Complete list of supported media
sizes along with their dimensions are listed in the ''Media
Size Table'' near the end of this document."
::= { intray1 1 }
tray1-fuser-temperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The fuser temperature to be used when printing media from Tray
1. The value zero is the default temperature. Values less than
zero are progressively lower and values greater than zero are
progressively higher. The range of values supported is device
specific.
Additional information:
The fuser temperature to be used when printing media from Tray
1. The value zero is the default temperature. Values less than
zero are progressively lower and values greater than zero are
progressively higher. The range of values supported is device
specific."
::= { intray1 13 }
tray2-media-size-loaded OBJECT-TYPE
SYNTAX INTEGER {
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eFoolscap(10),
eROC16K(17),
eISOandJISA5(25),
eISOandJISA4(26),
eISOandJISA6(24),
eROC16K195X270(34),
eJISB5(45)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns the media size that is currently configured in tray #2.
Complete list of supported media sizes along with their
dimensions are listed in the ''Media Size Table'' near the end
of this document."
::= { intray2 1 }
tray2-fuser-temperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The fuser temperature to be used when printing media from Tray
2. The value zero is the default temperature. Values less than
zero are progressively lower and values greater than zero are
progressively higher. The range of values supported is device
specific.
Additional information:
The fuser temperature to be used when printing media from Tray
2. The value zero is the default temperature. Values less than
zero are progressively lower and values greater than zero are
progressively higher. The range of values supported is device
specific."
::= { intray2 13 }
tray3-media-size-loaded OBJECT-TYPE
SYNTAX INTEGER {
eUSExecutive(1),
eUSLetter(2),
eUSLegal(3),
eFoolscap(10),
eISOandJISA6(24),
eISOandJISA5(25),
eISOandJISA4(26),
eJISB5(45),
eAnySize(32765)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns the media size that is currently configured in tray #3.
Complete list of supported media sizes along with their
dimensions are listed in the ''Media Size Table'' near the end
of this document."
::= { intray3 1 }
tray3-fuser-temperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The fuser temperature to be used when printing media from Tray
3. The value zero is the default temperature. Values less than
zero are progressively lower and values greater than zero are
progressively higher. The range of values supported is device
specific.
Additional information:
The fuser temperature to be used when printing media from Tray
3. The value zero is the default temperature. Values less than
zero are progressively lower and values greater than zero are
progressively higher. The range of values supported is device
specific."
::= { intray3 13 }
marker-density-calibration OBJECT-TYPE
SYNTAX INTEGER {
eNotCallibrating(1),
eCalibrateALL(2),
eCalibrateColor(3),
eCalibrateHalftone(4),
eCalibrateColorPlaneRegistration(5),
eCalibrateDrumPhaseAdjustment(6),
eCalibrateBlackOnly(7),
eCalibrateLowSpeedColor(8),
eCalibrateDrumSpeedAdjustment(9),
eCalibrateNeutrals(10)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns the calibration status or triggers a calibration cycle.
All calibration procedures are used if set to eCalibrateALL. If
set to eCalibrateColor then a full density engine calibration
is triggered. If set to eCalibrateHalftone, then a Halftone
calibration is triggered. If set to
eCalibrateColorPlaneRegistration, then a Color Plane
Registration calibration is triggered. If set to
eCalibrateDrumPhaseAdjustment, then a Drum Phase Adjustment
calibration is triggered.If set to eCalibrateLowSpeedColor,
then a Low Speed Color calibration is triggered.If set to
eCalibrateDrumSpeedAdjustment, then a Drum Speed Adjustment
calibration is triggered.If set to eCalibrateNeutrals, then a
Gray Axis Control calibration is triggered.
Additional information:
Returns the calibration status or triggers a calibration cycle.
All calibration procedures are used if set to eCalibrateALL. If
set to eCalibrateColor then a full density engine calibration
is triggered. If set to eCalibrateHalftone, then a Halftone
calibration is triggered. If set to
eCalibrateColorPlaneRegistration, then a Color Plane
Registration calibration is triggered. If set to
eCalibrateDrumPhaseAdjustment, then a Drum Phase Adjustment
calibration is triggered.If set to eCalibrateLowSpeedColor,
then a Low Speed Color calibration is triggered.If set to
eCalibrateDrumSpeedAdjustment, then a Drum Speed Adjustment
calibration is triggered.If set to eCalibrateNeutrals, then a
Gray Axis Control calibration is triggered."
::= { settings-marking-agent 11 }
default-ret OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eLight(2),
eMedium(3),
eDark(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the Resolution Enhancement Technology
setting. Devices that only support eOff and eOn should map all
other values to eOn and always return the same non-eOff value
to indicate on. The list of supported values should be
documented in the device POS."
::= { imaging 5 }
default-print-quality OBJECT-TYPE
SYNTAX INTEGER(0..100)
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or sets the default print quality. A value of zero has
the lowest print quality. A value of 100 has the highest print
quality. Each POS should document what values in the 0 to 100
range are supported.
Additional information:
The product supports
DEFAULT-PRINT-QUALITY in 300, 600, and 1200 dpi.
In the product, the supported values are 0 and
100. A value of zero has the lowest print quality
(ECONOMODE=ON), thus minimizes the amount of toner used
to print a page. A value of 100 has the highest print
quality (ECONOMODE=OFF), thus uses more toner to print a
page. Setting to an unsupported value outside of the 0
to 100 range causes the printer to return
<badValue> status.
Setting to an unsupported value inside of the 0 to 100
range causes the printer to substitute in a snap value
(listed below) and to return
<noError> status.
The snap values are as follow:
0 to 50 snaps to 0
51 to 100 snaps to 100"
::= { imaging 7 }
media-names-available OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "The value of this object controls which of the MEDIAx-NAME
objects are supported. If a bit is set to zero, then attempting
to get or set the corresponding MEDIAx-NAME objects will return
<noSuchName>.
Additional information:
Since this object is read-only, the corresponding MEDIAx
objects will always be available. The DEFAULTS below
represent which MediaNameX is available on this product
of the total possible available defined in SYNTAX, so the
collection is like a bitfield. "
::= { settings-print-media 1 }
media1-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..3))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 1 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media1 1 }
media1-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
The engine processing characteristics that are to
be applied to this media type. Currently, 'engine
processing characteristics' denotes changes to
fusing temperature and/or transfer roller voltage."
::= { media1 4 }
media2-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..5))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 2 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media2 1 }
media2-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media2 4 }
media3-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..10))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 3 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media3 1 }
media3-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media3 4 }
media4-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..10))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 4 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media4 1 }
media4-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media4 4 }
media5-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..12))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 5 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media5 1 }
media5-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media5 4 }
media6-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..10))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 6 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media6 1 }
media6-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media6 4 }
media8-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..4))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 8 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media8 1 }
media8-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media8 4 }
media12-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..5))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 12 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media12 1 }
media12-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media12 4 }
media13-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..5))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 13 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media13 1 }
media13-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media13 4 }
media14-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..5))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 14 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media14 1 }
media14-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media14 4 }
media15-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..5))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 15 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media15 1 }
media15-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media15 4 }
media16-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..5))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 16 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media16 1 }
media16-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media16 4 }
media17-name OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..5))
ACCESS read-only
STATUS optional
DESCRIPTION "Media 17 name.
Additional information:
The symbol set for this string is Roman-8."
::= { media17 1 }
media17-engine-media-mode OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The engine processing characteristics that are to be applied to
this media. The processing characteristics are device
specific.
Additional information:
See the description for MEDIA1-ENGINE-MEDIA-MODE."
::= { media17 4 }
engine-media-modes-supported1 OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "The list of engine media modes supported by the device. The
modes are each separated by a comma character. An example
string would be: 'Normal,Rough,Low,Vellum'."
::= { media-modes 1 }
pe-test-cause-assert OBJECT-TYPE
SYNTAX INTEGER {
e49DEAD(1),
e494C02(2),
e4900FF(3),
e80DEAD(4),
e81DEAD(5)
}
ACCESS write-only
STATUS optional
DESCRIPTION "This object allows the user to cause a 49 Error.
Additional information:
This object allows the user to cause a 49 Error."
::= { print-engine-test 111 }
pe-test-cause-79error OBJECT-TYPE
SYNTAX INTEGER {
e79DEAD(1)
}
ACCESS write-only
STATUS optional
DESCRIPTION "This object allows the user to cause a 79 Error.
Additional information:
This object allows the user to cause a 79 Error."
::= { print-engine-test 116 }
consumable-status-serial-number OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "This object is used to report the serial number for this
consumable."
::= { consumable-status 3 }
consumable-status-partnumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "This object will have one sub-array for the consumable and will
will hold the consumable's part number.
Additional information:
This object will have one sub-array for the consumable and will
will hold the consumable's part number."
::= { consumable-status 56 }
consumable-pages-printed-with-supply OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "This PML object returns the number of pages printed with a
cartridge consumable. This PML object returns the value that
should be displayed under 'Pages Printed With This Supply' for
cartridges in color products."
::= { consumables 11 }
consumable-life-usage-units-remaining OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "This object reports the current estimate of the number of usage
units that remain before this supply is depleted. An installed
supply that cannot report such a number will return a value of
-2. It is the reponsibility of the host application to query
each supply in order to determine an overall device
USAGE-UNITS-REMAINING number - the lowest value returned. The
unit of measure for this life estimate is determined by reading
the corresponding CONSUMABLE-LIFE-USAGE-UNITS object.
Additional information:
This object reports the approximate number of pages remaining
before this supply reaches very low. An installed cartridge that
cannot report such a number (because supply status is not
available) will return a value of -2. If the supply life is above
80% then this object will return ErrorActionCanNotBePerformedNow
(or genErr if queried through SNMP)."
::= { consumables-life 1 }
consumable-life-low-threshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object is used to report and modify a threshold value
indicating the point in the life of a consumable or supply at
which a transition to a LOW state will occur."
::= { consumables-life 3 }
consumable-test-password OBJECT-TYPE
SYNTAX INTEGER
ACCESS write-only
STATUS optional
DESCRIPTION "When set with the correct integer password value this object is
used to enable certain device specific test capabilities. When
set with any incorrect integer value, this object is used to
disable any device specific features previously enabled by this
object. This object will return a response of
<noSuchName> whenever an attempt is made to
query the object rather than
<noSuchName> so as to hide the
existence of this object from external host applications."
::= { consumables-test 1 }
scanner-jam-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates a count of the total pages jammed in the
scanner'slifetime."
::= { settings-scanner 43 }
scanner-adf-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates a count of the total pages scanned through the ADF on
the device. This may include scan to host jobs, copyjobs, and
fax jobs. If only the total pages scanned to the host are
wanted, use SCAN-ADF-PAGE-COUNT."
::= { settings-scanner 44 }
scan-adf-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Indicates the total pages scanned through the ADF to the host
from the device. If the total pages scanned through the scanner
are needed for all features, including copy and fax jobs, use
the SCANNER-ADF-PAGE-COUNT object."
::= { settings-scanner 45 }
scanner-retrieve-scanline OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS write-only
STATUS optional
DESCRIPTION "This object facilitates the sending of a scan line of data from
the scanner to a host. It grabs either raw or corrected data.
SERVICE-PASSWORD must be set correctly to use this object.
cScannerRequestRawScanLine - This is set by the host in
order to signal to the firmware that it wants a scan
line of raw (no PRNU or DSNU correction)data to be sent
back up to the host.
cScannerRequestCorrectedScanLine - This is set by the host
in order to signal to the firmware that it wants a scan
line of corrected (PRNU or DSNU correction) data to be
sent back up to the host.
cScannerSendDataRequest - This is set by firmware to
indicate that it has acquired the scan line from scan
engine and is ready to send the data to the host.
cScannerSendDataOK - This is set by the host to indicate
that it is ready to receive the data from the device.
cScannerSendDataDone - This is set by the firmware to
indicate that the transfer of data is complete.
cScannerPickSheet - This is set by the host to tell the
device to pick and stage the sheet of paper in the ADF.
cScannerFlushSheet - This is set by the host to tell the
device to flush the sheet of paper currently in the
device.
Additional information:
This object is meant to be used by Manufacturing
in order to facilitate the sending of a scan line of data from
the scanner over HDT. It
grabs either raw or corrected data.
cScannerRequestRawScanLine - This is set by the host in order
to signal to the firmware that it wants an scan line of raw
(no PRNU or DSNU correction)data to be sent back up to the
host.
cScannerRequestCorrectedScanLine - This is set by the host in
order to signal to the firmware that it wants a scan line of
corrected (PRNU or DSNU correction) data to be sent back up to
the host.
cScannerSendDataRequest - This is set by firmware to indicate
that it has acquired the scan line from scan engine and is
ready to send the data to the host.
cScannerSendDataOK - This is set by the host to
indicate that it is ready to receive the data from the device.
cScannerSendDataDone - This is set by the firmware to indicate
that the transfer of data is complete.
cScannerPickSheet - This is used for manufacturing to drop the
scan bogey to prevent damage during shipping. For LaserJet
3200, it was used to load a sheet in the ADF for shipping.
cScannerFlushSheet - This is set by the host to tell the
device to flush the sheet of paper currently in the device."
::= { settings-scanner 48 }
scanner-motor-control OBJECT-TYPE
SYNTAX INTEGER(-500..4680)
ACCESS write-only
STATUS optional
DESCRIPTION "This objects is set to the number of steps that the scan motor
should move. SERVICE-PASSWORD must be set correctly to use this
object.
Additional information:
This objects is set to the number of steps that
the scan motor should move. It is meant to be used by Manufacturing
in order to position the scanner shipping blocks.
The minimum value is -240, and the maximum is 4680. The value
set for this object will move the scan motor relative to the
home position. A value of 0 will use the find home algorithm
to move the scan motor home."
::= { settings-scanner 49 }
scanner-scanline-statistics OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "This object is used to obtain statistics about the scan line
that was previously obtained using the
SCANNER-RETRIEVE-SCANLINE object. Just as SERVICE-PASSWORD must
be set correctly for SCANNER-RETRIEVE-SCANLINE; it must be set
correctly to use this object as well.
Additional information:
This object is used to obtain statistics about
the scan line that was previously grabbed using the SCANNER_
RETRIEVE_SCANLINE object, max string is 256 bytes. The format
is the following: max red value; position; min red value; position;
max red pixel to pixel difference; position; red mean; max blue value;
position; min blue value; position; max blue pixel to pixel difference;
position; blue mean; max green value; position; min green value;
position; max green pixel to pixel difference; position; green mean;
red num band1; red num band2; red num band3;blue num band1; blue num band2;
blue num band3;green num band1; green num band2; green num band3;red num left;
red num right; blue num left; blue num right; green num left; green num right;
width in pixels; red num bad; blue num bad; green num bad;red num clipped;
blue num clipped; green num clipped;
As the device performs a scan calibration at startup these values will change
to the calibrated value and the default value will be modified. Hence testing
for default will not make any sense unless the calibration at the starup is
aborted."
::= { settings-scanner 51 }
scan-control-descriptor OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Describes the control language and formats supported for this
scanner.
Additional information:
This string is also used by Jetdirect Embedded WebScan"
::= { settings-scanner 52 }
scan-flatbed-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages scanned from
the flatbed."
::= { settings-scanner 73 }
scanner-flatbed-page-count OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "This object tracks the page count for the pages scanned for all
jobs from the flatbed. This includes scan to host jobs, fax
jobs, and copy jobs. "
::= { settings-scanner 74 }
scanner-modular-hardware OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Used to specify whether optional hardware is installed or not.
Additional information:
This HP LaserJet MFP uses this object to allow
a host to query whether or not it has an ADF installed,
Letter/A4 flatbed, or Legal flatbed."
::= { settings-scanner 75 }
scanner-clock-edge-modifiers OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "This object accesses a table used by firmware to modify clock
edge values for CCD scanner modules.
Additional information:
This object accesses a table used by firmware to modify
clock edge values for CCD scanner modules."
::= { settings-scanner 84 }
scan-clock-edges OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Returns a table of clock edges used by the scanner.
Additional information:
Returns a table of clock edges used by the scanner."
::= { settings-scanner 85 }
scan-emulate-copy OBJECT-TYPE
SYNTAX INTEGER {
eNo(1),
eYes(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Setting this object to eYes will cause firmware to run the next
scan job as if it were a copy job, using copy values for
scanner h/w and image processing, and then return the data to
the host as if it were a scan job. Setting this object to eNo
will cause firmware to process scan jobs in the normal way.
Additional information:
Setting this object to eYes will cause firmware to run
the next scan job as if it were a copy job, using copy
values for scanner h/w and image processing, and then
return the data to the host as if it were a scan job.
Setting this object to eNo will cause firmware to
process scan jobs in the normal way."
::= { settings-scanner 86 }
scan-calibration-target OBJECT-TYPE
SYNTAX INTEGER {
eWhiteSheet(1),
ePlaten(2)
}
ACCESS read-only
STATUS optional
DESCRIPTION "This object is used by the host to check which type of
calibration this scan device supports. The device pos will
describe the meaning and intent of each type of scan
calibration supported.
Additional information:
This object is used by the host to check which
type of calibration the firmware supports."
::= { scan-calibration 18 }
not-ready-source-scanner OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates whether and why the scanner is not ready. A set bit
indicates a problem.
Additional information:
ISSUES: Timberline only used
cScannerFeederJam. Tahiti does not have
an ADF sensor. Can cScannerFeederEmpty still
be used (i.e. when the device tries to pull
a page, but the ADF is empty or a mispick
occurred). cInvalidScannerMediaSize may be used.
If a page is longer that 33 inches normally this would be
shown to the host as a Jam. However, can the device
use cInvalidScannerMediaSize instead?"
::= { status-scanner 1 }
scan-calibration-download OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS optional
DESCRIPTION "Returns or changes the state of the calibration operation.
cScanCalibrationIdle - This indicates that the device is
not currently processing a
calibration request. The host
should not set the object to this state.
SCAN-CALIBRATION-ERROR state
will reflect results of most
recent calibration.
cScanCalibrationActive - The device sets this state to
indicate it is in calibration
mode. The device will set
SCAN-CALIBRATION-ERROR to eNoError(1) as a consequence
of entering this state.
cScanCalibrationOptical - This state is set by the host to
request factory optical
calibration initiation. The
device should not set to this state. The device will
ignore this request, without
error, if it is already in the
active or the done state.
cScanCalibrationADFFaceUpMechanical - This state is set by
the host to request factory
face up ADF mechanical calibration
initiation. The calibration
target should be placed face up in the ADF.
The device should not set to
this state. The device will
ignore this request, without error, if
it is already in the active or
the done state.
cScanCalibrationADFFaceDownMechanical - This state is set
by the host to request factory
face down ADF mechanical calibration
initiation. The calibration
target should be placed face down in the ADF.
The device should not set to
this state. The device will
ignore this request, without error, if
it is already in the active or
the done state.
cScanCalibrationFBMechanical - This state is set by the
host to request factory flat
bed mechanical calibration
initiation. The device should not set to this state.
The device will ignore this
request, without error, if it
is already in the active state.
cScanCalibrationADFResetMechanical - This state is set by
the host if he wants to start
ADF mechanical calibration all
over again. If this is set then both Face Up and Face
Down calibration can be started
even after a successful pass.
The device will NOT print a calibration graph when calibration
is complete.
Additional information:
Returns or changes the state of the calibration
operation.
cScanCalibrationIdle - indicates that calibration is not
in progress.
cScanCalibrationStart - This state is set by host to
request calibration initiation. Device should not set to
this state.
cScanCalibrationActive - Indicates device is in
calibration mode. Device sets cScanCalibrationActive to
signal calibration is in process.
cScanCalibrationAborted - Set by device to indicate
calibration was prematurely terminated. Set by host when
a calibration error occurs.
cScanCalibrationDone - Set by the host to inform the
device calibration is complete.
The device will print a calibration graph when
calibration is complete.The subarray indexes behaves the same way
as that of this object. The below are the list of subarray objects.
SCAN-CALIBRATION-DOWNLOAD-600 - 600 ppi scan with 600 array - host scan
SCAN-CALIBRATION-DOWNLOAD-1200 - 1200 ppi scan with 1200 array-host scan
SCAN-CALIBRATION-DOWNLOAD-300-MONO - 300 ppi scan with 300 array-mono copy
SCAN-CALIBRATION-DOWNLOAD-300-SCAN - 300 ppi scan with 600 array-host scan."
::= { status-scanner 5 }
scan-calibration-error OBJECT-TYPE
SYNTAX INTEGER {
eNoError(1),
eUnknownCalibrationError(2),
eScannerFeederEmpty(3),
eLowMemory(4),
eWriteFailed(5),
eScannerBusy(6),
eADFMispick(7),
eADFJam(8),
eUncorrectablePixels(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Error status of the most recent calibration session.
eNoError(1) - The calibation was successful.
eUnknownCalibrationError(2) - An unknown error occurred.
eScannerFeederEmpty(3) - The feeder contained nothing
to scan.
eLowMemory(4) - Insufficient memory available to complete
the calibration.
eWriteFailed(5) - Write to NVRAM failure.
eScannerBusy(6) - Scanner is busy.
Detailed information about the cause and remedy for each error
should be documented in the device POS.
Additional information:
This object was originally defined for use on
Timberline. We are proposing the new enums number 7-9.
Note: Option 9 would only be set during a factory calibration
to indicate that at least one pixel was not correctable by
the digital calibration factors."
::= { status-scanner 6 }
scanner-lamp-gain-value OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Provides PWM and analog gain for the color channels. The range
will vary based on scan mode. The device specific POS should
describe the valid range. The format is the following:
PWM value; red analog gain; green analog gain; blue analog
gain.
Additional information:
The range will vary based on scan mode. The values
will differ from those of San Diego. The initial value
can be obtained at the start of warmup and the final
value can be obtained at the end of warmup. The warmup period is about
2 minutes. The format is the following PWM value; red analog gain;
green analog gain; blue analog gain;. The valid values for PWM value
are 580 - 730 and the valid values for analog gains are 1.00-5.80.
The gains are reported with accuracy to 2 decimal places.
A sample return value would be '584;1.00;1.34;1.00;' "
::= { status-scanner 8 }
scanner-light-monitor-window OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Provides the pixel at which the LMW starts, as the ratio of the
average LMW value to the six pixel average value. The device
specific pos should specify the valid ranges for each value.
The format is the following:
LMW position; ratio of LMWavg to 6 pixel avg.
Additional information:
Provides the pixel at which the LMW starts as well as
the ratio of the average LMW value over a 6 pixel average value.
A algebraic representation of this ratio is:
Average of Light Monitor Window pixels
______________________________________
Average of 6 test point pixels
The 6 test point pixels do not inlcude any of the Light Monitor Window.
A sample return value would be '50;0.059;'. "
::= { status-scanner 9 }
scanner-reference-position OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Provides 3 pairs of x,y coordinates within a specified range of
the calibrate reference position. The device specific POS
should specify the valid ranges. The format is the following:
'x;y;x;y;x;y'
Additional information:
Provides x,y coordinates within 1/300 of a line of the
calibrate reference position. The 3 locations in order that are
reported are the 1st Reference Mark, the 2nd Reference Mark, and
the Document Origin. A sample return value would be
80,471;2523,2914;80,471;1;34326;27,32;193;35748;28,27;194;0,0;0;0;0;0;0;0;0,0;0;0;0;0;0;0;0,0;0;0,0;0;0;0
The extra 0's on the end are used specifically to gather information during
the cimation process. "
::= { status-scanner 10 }
scanner-sensor-manufacturer OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION "Reports the scan sensor manufacturer. The device specific POS
should list valid manufacturers.
Additional information:
Reports the scan sensor manufacturer. The device specific
POS should list valid manufacturers."
::= { status-scanner 11 }
pe-test-scanner-adf-voltage-start OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Set any attributes related to the ADF scanner voltage.
Additional information:
Set any attributes related to the ADF scanner start
voltage. Controls the ADF starve start voltage.
The possible values are 0-16 inclusive."
::= { pe-test-scanner-configuration 2 }
pe-test-scanner-adf-voltage-run OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Set any attributes related to the ADF scanner voltage.
Additional information:
Set attributes related to the ADF scanner run voltage.
Controls the ADF starve run voltage. The possible values
are 0-16 inclusive."
::= { pe-test-scanner-configuration 3 }
pe-test-scanner-flatbed-voltage-start OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Set any attributes related to the flatbed scanner voltage.
Additional information:
Set any attributes related to the flatbed scanner
start voltage.Controls the flatbed starve start voltage.
The possible values are 0-16 inclusive."
::= { pe-test-scanner-configuration 4 }
pe-test-scanner-flatbed-voltage-run OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "Set any attributes related to the flatbed scanner voltage.
Additional information:
Set attributes related to the flatbed scanner run
voltage.Controls the flatbed starve run voltage.
The possible values are 0-16 inclusive."
::= { pe-test-scanner-configuration 5 }
pe-test-scanner-test-config OBJECT-TYPE
SYNTAX INTEGER {
eOff(1),
eOn(2)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Configures the device for scanner test mode.
Additional information:
Configures the device for scanner test mode."
::= { pe-test-scanner-configuration 6 }
prtGeneralConfigChanges OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "Counts configuration changes that change the capabilities of
a printer, such as the addition/deletion of input/output bins,
the addition/deletion of interpreters, or changes in media
size. Such changes will often affect the capability of the
printer to service certain types of print jobs.
Management applications may cache infrequently changed
configuration information about sub-units on the printer.
This object should be incremented whenever the agent wishes
such applications to invalidate that cache and re-download
all of this configuration information, thereby signaling a
change in the printer's configuration.
For example, if an input tray that contained paper of
different dimensions was added, this counter would be
incremented.
As an additional example, this counter would not be
incremented when an input tray is removed or the level of an
input device changes.
Additional information:
This is a 32 bit counter (unsigned). When it
reaches its maximum value, it will roll to zero."
::= { prtGeneralEntry 1 }
prtGeneralCurrentLocalization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The value of the prtLocalizationIndex corresponding to the
current language, country, and character set to be used for
localized string values that are identified as being dependent
on the value of this object. Note that this object does not
apply to localized strings in the prtConsole group or to any
object that is not explicitly identified as being localized
according to prtGeneralCurrentLocalization."
::= { prtGeneralEntry 2 }
prtGeneralReset OBJECT-TYPE
SYNTAX INTEGER {
ePnotResetting(3),
ePpowerCycleReset(4),
ePresetToNVRAM(5),
ePresetToFactoryDefaults(6)
}
ACCESS read-write
STATUS optional
DESCRIPTION "Setting this value to `powerCycleReset', `resetToNVRAM', or
`resetToFactoryDefaults' will result in the resetting of the
printer. When read, this object will always have the value
`notResetting(3)', and a SET of the value `notResetting' shall
have no effect on the printer. Some of the defined values are
optional. However, every implementation must support at least
the values `notResetting' and 'resetToNVRAM'.
Additional information:
Setting this object to ePnotResetting causes the
printer to not reset.
Setting this object to ePpowerCycleReset causes this device
to do a reset.
Setting this object to 'resetToNVRAM' does NOT perform an NVRAM
init on the product. It causes the device to perform its power
on initialization routines. All I/O buffers are reset and tests
normally run at power on time are executed.
Setting the object to 'resetToFactoryDefaults, causes the
device to perform its reset to factory defaults routines.
Also, the device will perform a power cycle, which is required
to set all variables to their factory defaults."
::= { prtGeneralEntry 3 }
prtGeneralCurrentOperator OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..26))
ACCESS read-write
STATUS optional
DESCRIPTION "The name of the person who is responsible for operating
this printer. It is suggested that this string include
information that would enable other humans to reach the operator,
such as a phone number. As a convention to facilitate automatic
notification of the operator by the agent or the network
management station, the phone number, fax number or email address
should be placed on a separate line starting with ASCII LF (hex
0x0A) and the ASCII text string (without the quotes): 'phone: ',
'fax: ', and 'email: ', respectively. Phone numbers may contain
digits, whitespace and parentheses, which shall be ignored. Phone
numbers may also include ASCII comma characters(hex 2C) that are
used to indicate a two-second pause during the dialing sequence.
If either the phone, fax, or email information is not available,
then a line should not be included for this information.
NOTE: For interoperability purposes, it is advisable to use email
addresses formatted according to RFC 822 requirements.
Additional information:
The maximum supported string length is 26
characters.
If the user entered string is too long, the device will store
as much as possible and will return the
<noError> status."
::= { prtGeneralEntry 4 }
prtGeneralServicePerson OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..28))
ACCESS read-write
STATUS optional
DESCRIPTION "The name of the person responsible for servicing this
printer. It is suggested that this string include information
that would enable other humans to reach the service person, such
as a phone number. As a convention to facilitate automatic
notification of the service person by the agent or a network
management station, the phone number, fax number or email address
should be placed on a separate line starting with ASCII LF (hex
0x0A) and the ASCII text string (without the quotes): 'phone: ',
'fax: ', and 'email: ', respectively. Phone numbers may contain
digits, whitespace and parentheses, which shall be ignored. Phone
numbers can also include one or more ASCII comma characters(hex
2C) to indicate a two-second pause during the dialing sequence.
If either the phone,fax, or email information is not available,
then a line should not included for this information.
NOTE: For interoperability purposes, it is advisable to use email
addresses formatted according to RFC 822 requirements.
Additional information:
The maximum supported string length is 28
characters.
If the user entered string is too long, the device will store
as much as possible and will return the
<noError> status."
::= { prtGeneralEntry 5 }
prtInputDefaultIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The value of prtInputIndex corresponding to the default input
sub-unit: that is, this object selects the default source of
input media.
This value shall be -1 if there is no default input subunit specified
for the printer as a whole. In this case, the actual default
input subunit may be specified by means outside the scope of this
MIB, such as by each interpreter in a printer with multiple
interpreters.
Additional information:
The default input tray is determined by the
printer based on DEFAULT-MEDIA-SIZE, what trays are locked
(if any), and whether or not Tray 2 is installed.
This object always returns -1, unknown."
::= { prtGeneralEntry 6 }
prtOutputDefaultIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The value of prtOutputIndex corresponding to the default
output sub-unit; that is, this object selects the default
output destination.
This value shall be -1 if there is no default output subunit specified
for the printer as a whole. In this case, the actual default
output subunit may be specified by means outside the scope of this
MIB, such as by each interpreter in a printer with multiple
interpreters.
Additional information:
The product has only one output bin, a
face-down bin located at the top of the printer."
::= { prtGeneralEntry 7 }
prtMarkerDefaultIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The value of prtMarkerIndex corresponding to the
default marker sub-unit; that is, this object selects the
default marker.
Additional information:
The product only has one marker subunit."
::= { prtGeneralEntry 8 }
prtMediaPathDefaultIndex OBJECT-TYPE
SYNTAX INTEGER(1..3)
ACCESS read-only
STATUS optional
DESCRIPTION "The value of prtMediaPathIndex corresponding to
the default media path; that is, the selection of the
default media path.
Additional information:
The only valid value for this object is 1
(simplex)."
::= { prtGeneralEntry 9 }
prtConsoleLocalization OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS optional
DESCRIPTION "The value of the prtLocalizationIndex corresponding to
the language, country, and character set to be used for the
console. This localization applies both to the actual display
on the console as well as the encoding of these console
objects in management operations."
::= { prtGeneralEntry 10 }
prtConsoleNumberOfDisplayLines OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The number of lines on the printer's physical
display. This value is 0 if there are no lines on the
physical display or if there is no physical display."
::= { prtGeneralEntry 11 }
prtConsoleNumberOfDisplayChars OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The number of characters per line displayed on the physical
display. This value is 0 if there are no lines on the
physical display or if there is no physical display.
Additional information:
The device has a 16 character by 2 line display."
::= { prtGeneralEntry 12 }
prtConsoleDisable OBJECT-TYPE
SYNTAX INTEGER {
ePoperatorConsoleEnabled(3)
}
ACCESS read-only
STATUS optional
DESCRIPTION "If the object prtConsoleDisable has value
'operatorConsoleDisabled' then input is not accepted from the
operator console. If the object prtConsoleDisable has the value
'operatorConsoleEnabled' then input is accepted from the
operator console. If the object prtConsoleDisable has the value
'operatorConsoleEnabledLevel1','operatorConsoleEnabledLevel2' or
'operatorConsoleEnabledLevel3' then limited input is accepted
from the operator console; the limitations are product specific,
however, the limitations are generally less restrictive for
operatorConsoleEnabledLevel1 than for
operatorConsoleEnabledLeve2, which is less restrictive than
operatorConsoleEnabledLevel3.
The value of the prtConsoleDisable object is a type-2
enumeration."
::= { prtGeneralEntry 13 }
prtGeneralPrinterName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..32))
ACCESS read-write
STATUS optional
DESCRIPTION "An administrator-specified name for this printer.
Depending upon implementation of this printer, the value of this
object may or may not be same as the value for the MIB-II
'SysName' object.
Additional information:
The maximum supported string length is 32
characters. Length of 32 was chosen so a phone number could
be included with the name.
If the user-entered string is too long, the device will store
as much as possible and will return the
<noError> status. The value of this
object is saved over a power cycle."
::= { prtGeneralEntry 16 }
prtGeneralSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..11))
ACCESS read-only
STATUS optional
DESCRIPTION "A recorded serial number for this device that indexes some type
device catalog or inventory. This value is usually set by the
device manufacturer but the MIB supports the option of
writeability for this object for site-specific administration of
device inventory or tracking."
::= { prtGeneralEntry 17 }
prtAlertCriticalEvents OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "A running counter of the number of critical alert events
that have been recorded in the alert table. The value of this
object is RESET in the event of a power cycle operation (i.e.,
the value is not persistent.
Additional information:
This object is set to zero every time the
printer is turned on."
::= { prtGeneralEntry 18 }
prtAlertAllEvents OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "A running counter of the total number of alert event entries
(critical and non-critical) that have been recorded in the
alert table
Additional information:
This object is set to zero every time the
printer is turned on. (It is not persistent through a
power-cycle.)"
::= { prtGeneralEntry 19 }
prtCoverDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION "The manufacturer provided cover sub-mechanism name in the
localization specified by prtGeneralCurrentLocalization."
::= { prtCoverEntry 2 }
prtCoverStatus OBJECT-TYPE
SYNTAX INTEGER {
ePdoorOpen(3),
ePdoorClosed(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The status of this cover sub-unit."
::= { prtCoverEntry 3 }
prtLocalizationLanguage OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..2))
ACCESS read-only
STATUS optional
DESCRIPTION "A two character language code from ISO 639. Examples
en, gb, ca, fr, de."
::= { prtLocalizationEntry 2 }
prtLocalizationCountry OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..2))
ACCESS read-only
STATUS optional
DESCRIPTION "A two character country code from ISO 3166, a blank string
(two space characters) shall indicate that the country is
not defined. Examples: US, FR, DE, ..."
::= { prtLocalizationEntry 3 }
prtLocalizationCharacterSet OBJECT-TYPE
SYNTAX INTEGER {
ePcsHPRoman8(2004),
ePcsISOLatin2(5),
ePcsISOLatinCyrillic(8),
ePcsISOLatin5(12),
ePcsISOLatinGreek(10),
ePcsISOLatinHebrew(11),
ePcsISOLatinArabic(9),
ePcsUnicode(2000)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The coded character set used for this localization."
::= { prtLocalizationEntry 4 }
prtStorageRefIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The value of the hrDeviceIndex of the printer device that this
storageEntry is associated with."
::= { prtStorageRefEntry 2 }
prtDeviceRefIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The value of the hrDeviceIndex of the printer device that this
deviceEntry is associated with."
::= { prtDeviceRefEntry 2 }
prtInputType OBJECT-TYPE
SYNTAX INTEGER {
ePsheetFeedAutoRemovableTray(3),
ePsheetFeedAutoNonRemovableTray(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The type of technology (discriminated primarily according to
feeder mechanism type) employed by the input sub-unit. Note,
the Optional Input Class provides for a descriptor field to
further qualify the other choice.
Additional information:
Tray 1 is the multi-purpose tray and is always
present. It supports both sheets and envelopes. Its type is
ePsheetFeedAutoNonRemovableTray. The tray 2 object does not
exist when the tray is NOT installed."
::= { prtInputEntry 2 }
prtInputDimUnit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The unit of measurement for use calculating and relaying
dimensional values for this input sub-unit.
Additional information:
Following is a table of paper sizes and
dimensions for each paper size supported by
the product:
Size....................Inches(ten-thousandths)...Micrometers
-----------------------------------------------------------------
eUSExecutive............72500 x 105000............184150 x 266700
eUSLetter...............85000 x 110000............215900 x 279400
eUSLegal................85000 x 140000............215900 x 355600
eFoolscap...............85000 x 130000............215900 x 330200
eROC16K.................77500 x 107500............196850 x 273050
eISOandJISA4............82677 x 116929............210000 x 297000
eISOandJISA5............58286 x 82677.............148000 x 210000
eJISB5..................71654 x 101181............182000 x 257000
eIOSB5..................69300 x 98400.............176000 x 250000
eJapanesePostcardSingle.39370 x 58267.............100000 x 148000
eJapanesePostcardDouble.58267 x 78740.............148000 x 200000
eMonarch................38750 x 75000.............98425 x 190500
eCommercial10...........41250 x 95000.............104775 x 241300
eInternationalDL........43307 x 86614.............110000 x 220000
eInternationalC5........63780 x 90157.............162000 x 229000
eInternationalB5........69291 x 98425.............176000 x 250000
eCustom.................30000 x 140000(max).......76000 x 355600(max)"
::= { prtInputEntry 3 }
prtInputMediaDimFeedDirDeclared OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "This object provides the value of the declared dimension, in
the feed direction, of the media that is (or, if empty, was or
will be) in this input sub-unit. The feed direction is the
direction in which the media is fed on this sub-unit. This
dimension is measured in input sub-unit dimensional units
(prtInputDimUnit). If this input sub-unit can reliably sense
this value, the value is sensed by the printer and may not be
changed by management requests. Otherwise, the value may be
changed. The value (-1) means other and specifically means
that this sub-unit places no restriction on this parameter.
The value (-2) indicates unknown.
Additional information:
The default values assume the trays are
configured for letter size paper. For tray 1 the value is
the dimension for the media size currently declared.
Valid values are 50000 to 140000 if prtInputDimUnit is
ePtenThousandthsOfInches and 127000 to 355600 if
prtInputDimUnit is ePmicrometers."
::= { prtInputEntry 4 }
prtInputMediaDimXFeedDirDeclared OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "This object provides the value of the declared dimension, in
the cross feed direction, of the media that is (or, if empty,
was or will be) in this input sub-unit. The cross feed
direction is ninety degrees relative to the feed direction
associated with this sub-unit. This dimension is measured in
input sub-unit dimensional units (prtInputDimUnit). If this
input sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by management
requests. Otherwise, the value may be changed. The value (-1)
means other and specifically means that this sub-unit places
no restriction on this parameter. The value (-2) indicates
unknown.
Additional information:
The default values assume the trays are
configured for letter size paper. For trays 1 & 2, the value
is the dimension for the media size currently declared.
Valid values are 30000 to 85000 if prtInputDimUnit is
ePtenThousandthsOfInches and 76000 to 216000 if
prtInputDimUnit is ePmicrometers. The minimum
value for tray 2 is 72500 (tenthousandsinch)
and 191000(micrometers)."
::= { prtInputEntry 5 }
prtInputMediaDimFeedDirChosen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The printer will act as if media of the chosen dimension (in
the feed direction) is present in this input source. Note
that this value will be used even if the input tray is empty.
Feed dimension measurements are taken relative to the feed
direction associated with that sub-unit and are in input sub-unit
dimensional units (MediaUnit). If the printer supports the
declared dimension, the granted dimension is the same as
the declared dimension. If not, the granted dimension is
set to the closest dimension that the printer supports
when the declared dimension is set. The value (-1) means
other and specifically indicates that this sub-unit
places no restriction on this parameter. The value (-2)
indicates unknown.
Additional information:
The default value assumes the trays are configured
for letter size paper. The objects for the trays
return the value of the media size for which the trays
are currently configured because it cannot sense what size
media they contain."
::= { prtInputEntry 6 }
prtInputMediaDimXFeedDirChosen OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The printer will act as if media of the chosen dimension (in
the cross feed direction) is present in this input source.
Note that this value will be used even if the input tray is
empty. The cross feed direction is ninety degrees relative
to the feed direction associated with this sub-unit. This
dimension is measured in input sub-unit dimensional units
(MediaUnit). If the printer supports the declared
dimension, the granted dimension is the same as the
declared dimension. If not, the granted dimension is set
to the closest dimension that the printer supports when
the declared dimension is set. The value (-1) means other
and specifically indicates that this sub-unit places no
restriction on this parameter. The value (-2) indicates
unknown.
Additional information:
The default value assumes the trays are configured
for letter size paper. The object for the trays
return the value of the media size for which the trays
are currently configured because it cannot sense what size
media it contains."
::= { prtInputEntry 7 }
prtInputCapacityUnit OBJECT-TYPE
SYNTAX INTEGER {
ePsheets(8)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The unit of measurement for use in calculating and relaying
capacity values for this input sub-unit.
Additional information:
A sheet is a single piece of 20 pound paper. "
::= { prtInputEntry 8 }
prtInputMaxCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum capacity of the input sub-unit in input
sub-unit capacity units (PrtCapacityUnitTC). There is no
convention associated with the media itself so this value
reflects claimed capacity. If this input sub-unit can
reliably sense this value, the value is sensed by the
printer and may not be changed by management requests;
otherwise, the value may be written (by a Remote
Control Panel or a Management Application).
The value (-1) means other and specifically
indicates that the sub-unit places no restrictions
on this parameter. The value (-2) means unknown.
Additional information:
This is specified assuming 20 pound paper for
the paper trays."
::= { prtInputEntry 9 }
prtInputCurrentLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The current capacity of the input sub-unit in input
sub-unit capacity units (PrtCapacityUnitTC). If this input
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by
management requests; otherwise, the value may
be written (by a Remote Contol Panel or a
Management Application). The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means unknown.
The value (-3) means that the printer knows that at least one
unit remains.
Additional information:
The product can only detect
empty/not empty in its trays. It returns -3 for not empty
and -2 (unknown) for any other condition (e.g. tray is empty
or tray is removed)."
::= { prtInputEntry 10 }
prtInputStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The current status of this input sub-unit.
Additional information:
The default value assumes that media is loaded
in the tray. When there is not media loaded in the tray it
returns 9 instead of 0 (the default).
Default - 0 (Available and Idle)
paper motion - 6 (Available and Busy)
paper out in this tray - 9 (Non-Critical Alert(8) + Unavailable and OnRequest(1))
paper mount in this tray - 48 (Critical Alert (16) + OffLine (32))
manual feed prompt (PaperMount) - 48 (Critical Alert (16) + OffLine (32))"
::= { prtInputEntry 11 }
prtInputMediaName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-write
STATUS optional
DESCRIPTION "A description of the media contained in this input sub-unit;
This description is intended for display to a human operator.
This description is not processed by the printer. It is used
to provide information not expressible in terms of the other
media attributes (e.g. prtInputMediaDimFeedDirChosen,
prtInputMediaDimXFeedDirChosen, prtInputMediaWeight,
prtInputMediaType). An example would be `legal tender bond
paper'.
Additional information:
The product supports the
concept of named media types. The values for this
object will always match one of the MEDIAn-NAME objects."
::= { prtInputEntry 12 }
prtInputName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION "The name assigned to this input sub-unit."
::= { prtInputEntry 13 }
prtInputVendorName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION "The vendor name of this input sub-unit."
::= { prtInputEntry 14 }
prtInputModel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION "The model name of this input sub-unit.
Additional information:
The product does not specify model
names for the input trays."
::= { prtInputEntry 15 }
prtInputVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION "The version of this input sub-unit.
Additional information:
The product does not specify version
numbers for the input trays."
::= { prtInputEntry 16 }
prtInputSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..63))
ACCESS read-only
STATUS optional
DESCRIPTION "The serial number assigned to this input sub-unit.
Additional information:
The product does not specify serial
numbers for the input trays."
::= { prtInputEntry 17 }
prtInputDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION "A free-form text description of this input
sub-unit in the localization specified by
prtGeneralCurrentLocalization."
::= { prtInputEntry 18 }
prtInputSecurity OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePon(3),
ePoff(4),
ePnotPresent(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates if this input sub-unit has some security
associated with it.
Additional information:
No security mechanism provided."
::= { prtInputEntry 19 }
prtOutputType OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePunknown(2),
ePremovableBin(3),
ePunRemovableBin(4),
ePcontinuousRollDevice(5),
ePmailBox(6),
ePcontinousFanFold(7)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The type of technology supported by this output sub-unit.
Additional information:
The product has only one output bin, a
face-down bin located at the top of the printer."
::= { prtOutputEntry 2 }
prtOutputCapacityUnit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4),
ePsheets(8),
ePfeet(16),
ePmeters(17)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The unit of measurement for use in calculating and relaying
capacity values for this output sub-unit.
Additional information:
A sheet is a single piece of 20 pound paper."
::= { prtOutputEntry 3 }
prtOutputMaxCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum capacity of this output sub-unit in output
sub-unit capacity units (PrtCapacityUnitTC). There is no
convention associated with the media itself so this value
essentially reflects claimed capacity. If this output
sub-unit can reliably sense this value, the value is
sensed by the printer and may not be changed by management
requests; otherwise, the value may be written
(by a Remote Control Panel or a Management Application).
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this parameter.
The value (-2) means unknown.
Additional information:
Note: The product cannot sense how
much is in the output bin. The output bin can hold 125
sheets."
::= { prtOutputEntry 4 }
prtOutputRemainingCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The remaining capacity of the possible output sub-unit
capacity in output sub-unit capacity units (PrtCapacityUnitTC)
of this output sub-unit. If this output sub-unit can
reliably sense this value, the value is sensed by the
printer and may not be modified by management requests;
otherwise, the value may be written (by
a Remote Control Panel or a Management
Application). The value (-1) means other and
specifically indicates that the sub-unit places no
restrictions on this parameter. The value (-2) means
unknown. The value (-3) means that the printer knows that
there remains capacity for at least one unit.
Additional information:
The product does not have any sensing
on the output bin, so it will always report unknown (-2).
Note that for the products, this object is read-only
because any values written by a Remote Control Panel or a
Management Application would be unreliable."
::= { prtOutputEntry 5 }
prtOutputStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The current status of this output sub-unit.
Additional information:
The product cannot sense the output
tray so this object will always return 5 (Unknown Status)."
::= { prtOutputEntry 6 }
prtMarkerMarkTech OBJECT-TYPE
SYNTAX INTEGER {
ePelectrophotographicLaser(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The type of marking technology used for this marking sub-unit."
::= { prtMarkerEntry 2 }
prtMarkerCounterUnit OBJECT-TYPE
SYNTAX INTEGER {
ePimpressions(7)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The unit that will be used by the printer when reporting
counter values for this marking sub-unit. The
time units of measure are provided for a device like a
strip recorder that does not or cannot track the physical
dimensions of the media and does not use characters,
lines or sheets.
Additional information:
Since the product keeps track of pages
printed, the counter unit will be defined as ePimpressions
which would be like saying pages printed. (The term
'impressions' is used instead of 'pages' to avoid confusion
between 'sheets' and 'pages' on a duplexing printer.)"
::= { prtMarkerEntry 3 }
prtMarkerLifeCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The count of the number of units of measure counted during
the life of printer using units of measure as specified by
prtMarkerCounterUnit.
Additional information:
In the product, the total engine page
count is kept in NVRAM, however the NVRAM value is only
updated every 10 impressions.
NOTE: The value returned by this OID will be incremented
every page but if power is lost between NVRAM updates, up to
9 impressions of the page count may be lost. The counter
will be reset to zero after 999999 pages.
The page count is incremented when a sheet of media is pulled
from an input tray."
::= { prtMarkerEntry 4 }
prtMarkerPowerOnCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The count of the number of units of measure counted since the
equipment was most recently powered on using units of measure as
specified by prtMarkerCounterUnit."
::= { prtMarkerEntry 5 }
prtMarkerProcessColorants OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The number of process colors supported by this marker. A
process color of 1 implies monochrome. The value of this
object and prtMarkerSpotColorants cannot both be 0. The value of
prtMarkerProcessColorants must be 0 or greater."
::= { prtMarkerEntry 6 }
prtMarkerSpotColorants OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The number of spot colors supported by this marker. The
value of this object and prtMarkerProcessColorants cannot
both be 0. Must be 0 or greater."
::= { prtMarkerEntry 7 }
prtMarkerAddressabilityUnit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The unit of measure of distances, as applied to the marker's
resolution.
Additional information:
This will always be ePtenThousandthsOfInches, no
matter what COLD-RESET-MEDIA-SIZE is because we are talking
about resolution and toner addressability, which is always
dpi."
::= { prtMarkerEntry 8 }
prtMarkerAddressabilityFeedDir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum number of addressable marking positions in the feed
direction per 10000 units of measure specified by
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
'infinite' while a value of (-2) implies 'unknown'.
Additional information:
Use this object to specify resolution. The
product supports 600 dots per inch."
::= { prtMarkerEntry 9 }
prtMarkerAddressabilityXFeedDir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum number of addressable marking positions in the cross
feed direction in 10000 units of measure specified by
prtMarkerAddressabilityUnit. A value of (-1) implies 'other' or
'infinite' while a value of (-2) implies 'unknown'.
Additional information:
Use this object to specify resolution. The
product supports 600 dots per inch."
::= { prtMarkerEntry 10 }
prtMarkerNorthMargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The margin, in units identified by prtMarkerAddressabilityUnit,
from the leading edge of the medium as the medium flows
through the marking engine with the side to be imaged
facing the observer. The leading edge is the North edge
and the other edges are defined by the normal compass
layout of directions with the compass facing the
observer. Printing within the area bounded by all four
margins is guaranteed for all interpreters. The value
(-2) means unknown."
::= { prtMarkerEntry 11 }
prtMarkerSouthMargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The margin from the South edge (see prtMarkerNorthMargin)
of the medium in units identified by
prtMarkerAddressabilityUnit. Printing within the area bounded by
all four margins is guaranteed for all interpreters.
The value (-2) means unknown."
::= { prtMarkerEntry 12 }
prtMarkerWestMargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The margin from the West edge (see prtMarkerNorthMargin) of the
medium in units identified by prtMarkerAddressabilityUnit.
Printing within the area bounded by all four margins is
guaranteed for all interpreters. The value (-2) means
unknown."
::= { prtMarkerEntry 13 }
prtMarkerEastMargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The margin from the East edge (see prtMarkerNorthMargin) of the
medium in units identified by prtMarkerAddressabilityUnit.
Printing within the area bounded by all four margins is
guaranteed for all interpreters. The value (-2) means
unknown."
::= { prtMarkerEntry 14 }
prtMarkerStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The current status of this marker sub-unit.
Additional information:
The default value assumes the printer is idle
and has no malfunctions.
Default - 0 (Available and Idle)
no toner cartridge - 51 (UnAvailable because Broken (3) + Critical Alert (16) + OffLine (32))"
::= { prtMarkerEntry 15 }
prtMarkerSuppliesMarkerIndex OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The value of prtMarkerIndex corresponding to the
marking sub-unit with which this marker supply
sub-unit is associated."
::= { prtMarkerSuppliesEntry 2 }
prtMarkerSuppliesColorantIndex OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The value of prtMarkerColorantIndex
corresponding to the colorant with which this
marker supply sub-unit is associated. This value
shall be 0 if there is no colorant table."
::= { prtMarkerSuppliesEntry 3 }
prtMarkerSuppliesClass OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePsupplyThatIsConsumed(3),
ePreceptacleThatIsFilled(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates whether this supply entity represents a supply
that is consumed or a receptacle that is filled."
::= { prtMarkerSuppliesEntry 4 }
prtMarkerSuppliesType OBJECT-TYPE
SYNTAX INTEGER {
ePtoner(3),
ePtransferUnit(20),
ePtonerCartridge(21),
ePfuser(15),
ePdeveloper(10),
ePfuserCleaingPad(19),
ePopc(9)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The type of this supply."
::= { prtMarkerSuppliesEntry 5 }
prtMarkerSuppliesDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION "The description of this supply container/receptacle in the
localization specified by prtGeneralCurrentLocalization.
Additional information:
"
::= { prtMarkerSuppliesEntry 6 }
prtMarkerSuppliesSupplyUnit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4),
ePimpressions(7),
ePsheets(8),
ePthousandthsOfOunces(12),
ePhours(11),
ePtenthsOfGrams(13),
ePhundrethsOfFluidOunces(14),
ePtenthsOfMilliliters(15),
ePfeet(16),
ePmeters(17),
ePpercent(19)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Unit of measure of this marker supply container/receptacle."
::= { prtMarkerSuppliesEntry 7 }
prtMarkerSuppliesMaxCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum capacity of this supply container/receptacle
expressed in prtMarkerSuppliesSupplyUnit. If this supply
container/receptacle can reliably sense this value, the
value is reported by the printer and is read-only;
otherwise, the value may be written (by a Remote Control
Panel or a Management Application). The value (-1) means
other and specifically indicates that the sub-unit places
no restrictions on this parameter. The value (-2) means
unknown.
Additional information:
This object reports the maximum capacity for the supply
against which the level is reported."
::= { prtMarkerSuppliesEntry 8 }
prtMarkerSuppliesLevel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The current level if this supply is a container; the
remaining space if this supply is a receptacle. If this
supply container/receptacle can reliably sense this
value, the value is reported by the printer and is
read-only; otherwise, the value may be written (by a
Remote Control Panel or a Management Application). The
value (-1) means other and specifically indicates that
the sub-unit places no restrictions on this parameter.
The value (-2) means unknown. A value of (-3) means that the
printer knows that there is some supply/remaining space,
respectively.
Additional information:
Print Cartridges measure life based on the three
components: toner, developer and drum. These Print
Cartridge object (1) report the lowest of these
three factors. Print Cartridges that are not
installed will return a value of 100."
::= { prtMarkerSuppliesEntry 9 }
prtMarkerColorantMarkerIndex OBJECT-TYPE
SYNTAX INTEGER(0..65535)
ACCESS read-only
STATUS optional
DESCRIPTION "The value of prtMarkerIndex corresponding to the
marker sub-unit with which this colorant entry is
associated."
::= { prtMarkerColorantEntry 2 }
prtMarkerColorantRole OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePprocess(3),
ePspot(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The role played by this colorant."
::= { prtMarkerColorantEntry 3 }
prtMarkerColorantValue OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION "The name of the color of this
colorant using standardized string names from ISO 10175 (DPA)
and ISO 10180 (SPDL) which are:
other
unknown
white
red
green
blue
cyan
magenta
yellow
black
Implementors may add additional string values. The naming
conventions in ISO 9070 are recommended in order to avoid
potential name clashes.
Additional information:
"
::= { prtMarkerColorantEntry 4 }
prtMarkerColorantTonality OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The distinct levels of tonality realizable by a marking
sub-unit when using this colorant. This value does not
include the number of levels of tonal difference that an
interpreter can obtain by techniques such as half toning.
This value must be at least 2."
::= { prtMarkerColorantEntry 5 }
prtMediaPathMaxSpeedPrintUnit OBJECT-TYPE
SYNTAX INTEGER {
ePimpressionsPerHour(7)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The unit of measure used in specifying the speed of all media
paths in the printer.
Additional information:
ePimpressionsPerHour is the value that will
always be returned for this object. (Print Speed is measured
in pages-per-minute (impressions per minute), so
ePimpressionsPerHour is a natural extension.)"
::= { prtMediaPathEntry 2 }
prtMediaPathMediaSizeUnit OBJECT-TYPE
SYNTAX INTEGER {
ePtenThousandthsOfInches(3),
ePmicrometers(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The units of measure of media size for use in calculating and
relaying dimensional values for all media paths in the printer."
::= { prtMediaPathEntry 3 }
prtMediaPathMaxSpeed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum printing speed of this media path expressed in
prtMediaPathMaxSpeedUnit's. A value of (-1) implies
'other'.
Additional information:
The page size for this performance is 8.5 x 11. For
the product, this value is (12ppm * 60)."
::= { prtMediaPathEntry 4 }
prtMediaPathMaxMediaFeedDir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum physical media size in the feed direction of this
media path expressed in units of measure specified by
PrtMediaPathMediaSizeUnit. A value of (-1) implies 'unlimited',
a value of (-2) implies 'unknown'.
Additional information:
The value returned by this object depends on the
value of prtMediaPathMediaSizeUnit. It is 140000 if
prtInputDimUnit is ePtenThousandthsOfInches or 355600 if
prtInputDimUnit is ePmicrometers. (140000 is the value
arrived at because legal paper is the longest allowable on
the product.)"
::= { prtMediaPathEntry 5 }
prtMediaPathMaxMediaXFeedDir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum physical media size across the feed direction of
this media path expressed in units of measure specified by
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
Additional information:
The value returned by this object depends on the
value of prtMediaPathMediaSizeUnit. It is 85000 if
prtInputDimUnit is ePtenThousandthsOfInches or 216000 if
prtInputDimUnit is ePmicrometers."
::= { prtMediaPathEntry 6 }
prtMediaPathMinMediaFeedDir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The minimum physical media size in the feed direction of this
media path expressed in units of measure specified by
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
Additional information:
The value returned by this object depends on the
value of prtMediaPathMediaSizeUnit. It is 50000 if
prtInputDimUnit is ePtenThousandthsOfInches or 127000 if
prtInputDimUnit is ePmicrometers."
::= { prtMediaPathEntry 7 }
prtMediaPathMinMediaXFeedDir OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The minimum physical media size across the feed direction of
this media path expressed in units of measure specified by
prtMediaPathMediaSizeUnit. A value of (-2) implies 'unknown'.
Additional information:
The value returned by this object depends on the
value of prtMediaPathMediaSizeUnit. It is 30000 if
prtInputDimUnit is ePtenThousandthsOfInches or 76200 if
prtInputDimUnit is ePmicrometers. This size corresponds to a
Monarch envelope. "
::= { prtMediaPathEntry 8 }
prtMediaPathType OBJECT-TYPE
SYNTAX INTEGER {
ePlongEdgeBindingDuplex(3),
ePsimplex(5)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The type of the media path for this media path.
Additional information:
This object describes how many paths there are
through the engine disregarding the paper source (tray 1, 2,
or 3)."
::= { prtMediaPathEntry 9 }
prtMediaPathDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION "The manufacturer-provided description of this media path in
the localization specified by prtGeneralCurrentLocalization."
::= { prtMediaPathEntry 10 }
prtMediaPathStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The current status of this media path.
Additional information:
The default values assume the printer is idle.
Default - 0 (Available and Idle)
paper motion - 6 (Available and Busy)
paper out in all trays - 9 (Non-Critical Alert(8) + Unavailable and OnRequest(1))
paper mount (any tray) - 0 (Available and Idle)
manual feed prompt (PaperMount) - 48 (Critical Alert (16) + OffLine (32))"
::= { prtMediaPathEntry 11 }
prtInterpreterLangFamily OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePlangPCL(3),
ePlangPJL(5),
ePlangPS(6),
ePlangAutomatic(37),
ePlangPCLXL(47)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The family name of a Page Description Language (PDL) or
control language which this interpreter in the printer can
interpret or emulate.
Additional information:
ePlangAutomatic refers to the 'super-language'
made available by implicit language switching."
::= { prtInterpreterEntry 2 }
prtInterpreterLangLevel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
ACCESS read-only
STATUS optional
DESCRIPTION "The level of the language which this interpreter is
interpreting or emulating. This might contain a value like
'5e' for an interpreter which is emulating level 5e of the PCL
language. It might contain '2' for an interpreter which is
emulating level 2 of the PostScript language. Similarly it
might contain '2' for an interpreter which is emulating level
2 of the HPGL language."
::= { prtInterpreterEntry 3 }
prtInterpreterLangVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
ACCESS read-only
STATUS optional
DESCRIPTION "The date code or version of the language which this interpreter
is interpreting or emulating.
Additional information:
These values are derived from the dateCode field
of the personality entities. (ePlangautomatic uses the PJL
dateCode.) For PostScript, this is more detailed revision
information."
::= { prtInterpreterEntry 4 }
prtInterpreterDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION "A string to identify this interpreter in the localization
specified by prtGeneralCurrentLocalization as opposed to the
language which is being interpreted. It is anticipated that
this string will allow manufacturers to unambiguously identify
their interpreters.
Additional information:
None of these strings are localized."
::= { prtInterpreterEntry 5 }
prtInterpreterVersion OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..31))
ACCESS read-only
STATUS optional
DESCRIPTION "The date code, version number, or other product specific
information tied to this interpreter. This value is
associated with the interpreter, rather than with the version
of the language which is being interpreted or emulated.
Additional information:
Same as prtInterpreterLangVersion."
::= { prtInterpreterEntry 6 }
prtInterpreterDefaultOrientation OBJECT-TYPE
SYNTAX INTEGER {
ePportrait(3),
ePlandscape(4)
}
ACCESS read-write
STATUS optional
DESCRIPTION "The current orientation default for this interpreter. This
value may be overridden for a particular job (e.g., by a
command in the input data stream).
Additional information:
Interpreters 1 and 2 ignore the value of this
object.
The values for PCL and PostScript are either ePportrait or
ePlandscape; attempting to set them to a different value will
cause <badValue> to be returned.
Setting this object for one interpreter will change it for
all installed interpreters."
::= { prtInterpreterEntry 7 }
prtInterpreterFeedAddressability OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum interpreter addressability in the feed
direction in 10000 prtMarkerAddressabilityUnits (see
prtMarkerAddressabilityFeedDir ) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this parameter."
::= { prtInterpreterEntry 8 }
prtInterpreterXFeedAddressability OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "The maximum interpreter addressability in the cross feed
direction in 10000 prtMarkerAddressabilityUnits (see
prtMarkerAddressabilityXFeedDir) for this interpreter.
The value (-1) means other and specifically indicates
that the sub-unit places no restrictions on this
parameter."
::= { prtInterpreterEntry 9 }
prtInterpreterDefaultCharSetIn OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePcsASCII(3),
ePcsISOLatin1(4),
ePcsISOLatin2(5),
ePcsISOLatin5(12),
ePcsISOLatin6(13),
ePcsISOLatin9(2090),
ePcsISO4UnitedKingdom(20),
ePcsISO11SwedishforNames(21),
ePcsISO15Italian(22),
ePcsISO17Spanish(23),
ePcsISO21German(24),
ePcsISO60DanishNorwegian(25),
ePcsISO69French(26),
ePcsUnicodeIBM2039(1004),
ePcsWindows30Latin1(2000),
ePcsWindows31Latin1(2001),
ePcsWindows31Latin2(2002),
ePcsWindows31Latin5(2003),
ePcsHPRoman8(2004),
ePcsAdobeStandardEncoding(2005),
ePcsPC850Multilingual(2009),
ePcsPC858Multilingual(2089),
ePcsPCp852(2010),
ePcsPC8CodePage437(2011),
ePcsPC8DNDanishNorwegian(2012),
ePcsHPPC8Turkish(2014),
ePcsHPLegal(2017),
ePcsHPDeskTop(2021),
ePcsMacintosh(2027),
ePcsPC77Baltic(2087),
ePcsWindows1257Baltic(2257)
}
ACCESS read-write
STATUS optional
DESCRIPTION "The default coded character set for input octets
encountered outside a context in which the Page
Description Language established the interpretation
of the octets. (Input octets are presented to the
interpreter through a path defined in the channel group.)
This value shall be (2) if there is no default.
Additional information:
ePcsAdobeStandardEncoding is the same as PSText(10J).
The object corresponding to PCL has read-write access;
all others are read-only.
Note: To determine which languages correspond to which subarrays refer
to the object prtInterpreterLangFamily.
The above list corresponds to the following symbol sets as they appear
on the Control Panel:
ePother( 1) - used if designated coded char. set not in list
ePcsASCII( 3) - ISO-6
ePcsISOLatin1( 4) - ISO L1
ePcsISOLatin2( 5) - IS L2
ePcsISOLatin5( 12) - ISO L5
ePcsISOLatin6( 13) - ISO L6
ePcsISOLatin9( 2090) - ISO L9
ePcsISO4UnitedKingdom( 20) - ISO-4
ePcsISO11SwedishforNames( 21) - ISO-11
ePcsISO15Italian( 22) - ISO-15
ePcsISO17Spanish( 23) - ISO-17
ePcsISO21German( 24) - ISO-21
ePcsISO60DanishNorwegian( 25) - ISO-60
ePcsISO69French( 26) - ISO-69
ePcsUnicodeIBM2039(1004) - PC-1004
ePcsWindows30Latin1( 2000) - WIN 3.0
ePcsWindows31Latin1( 2001) - WIN L1
ePcsWindows31Latin2( 2002) - WIN L2
ePcsWindows31Latin5( 2003) - WIN L5
ePcsHPRoman8( 2004) - ROMAN-8
ePcsAdobeStandardEncoding( 2005) - PS TEXT
ePcsPC850Multilingual( 2009) - PC-850
ePcsPC858Multilingual( 2089) - PC-858
ePcsPCp852( 2010) - PC-852
ePcsPC8CodePage437( 2011) - PC-8
ePcsPC8DNDanishNorwegian( 2012) - PC-8DN
ePcsHPPC8Turkish( 2014) - PC-8 TK
ePcsHPLegal( 2017) - LEGAL
ePcsHPDeskTop( 2021) - DESKTOP
ePcsMacintosh( 2027) - MC TEXT
ePcsPC77Baltic( 2087) - PC-775
ePcsWindows1257Baltic( 2257) - WINBALT"
::= { prtInterpreterEntry 10 }
prtInterpreterDefaultCharSetOut OBJECT-TYPE
SYNTAX INTEGER {
ePcsNoDefault(2),
ePcsASCII(3),
ePcsHPRoman8(2004),
ePcsAdobeStandardEncoding(2005)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The default character set for data coming from this interpreter
through the printer's output channel (i.e. the 'backchannel').
This value shall be (2) if there is no default."
::= { prtInterpreterEntry 11 }
prtInterpreterTwoWay OBJECT-TYPE
SYNTAX INTEGER {
ePyes(3),
ePno(4)
}
ACCESS read-only
STATUS optional
DESCRIPTION "Indicates whether or not this interpreter returns information
back to the host."
::= { prtInterpreterEntry 12 }
prtConsoleDisplayBufferText OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION "The content of a line in the logical display buffer of
the operator's console of the printer. When a write
operation occurs, normally a critical message, to one of
the LineText strings, the agent should make that line
displayable if a physical display is present. Writing
a zero length string clears the line. It is an
implementation-specific matter as to whether the agent allows
a line to be overwritten before it has been cleared.
Printer generated strings shall be in the localization
specified by prtConsoleLocalization. Management Application
generated strings should be localized by the Management
Application.
Additional information:
In the case of a 2-line display message,
prtConsoleDisplayBufferText.1 maps to the first
line and prtConsoleDisplayBufferText.2 maps to
the second. In the case of a 1-line display
message, prtConsoleDisplayBufferText.1 maps to
the first line and prtConsoleDisplayBufferText.2
return NULL."
::= { prtConsoleDisplayBufferEntry 2 }
prtConsoleOnTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "This object, in conjunction with prtConsoleOffTime, defines
the current status of the light. If both prtConsoleOnTime and
prtConsoleOffTime are non-zero, the lamp is blinking and the
values presented define the on time and off time, respectively,
in milliseconds. If prtConsoleOnTime is zero and
prtConsoleOffTime is non-zero, the lamp is off. If
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
the lamp is on. If both values are zero the status of the
lamp is undefined.
Additional information:
There are two control panel LEDs: Attention
and Ready. When an LED blinks, it is on for one half
second and off for one half second. The value used for this
object is 500 when the LED is on or blinking, otherwise it is
zero.
When the LEDs are in a cycling state the value of this object
for all LEDs is zero and the value for prtConsoleOffTime for
all LEDs is zero."
::= { prtConsoleLightEntry 2 }
prtConsoleOffTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS optional
DESCRIPTION "This object, in conjunction with prtConsoleOnTime, defines
the current status of the light. If both prtConsoleOnTime and
prtConsoleOffTime are non-zero, the lamp is blinking and the
values presented define the on time and off time, respectively,
in milliseconds. If prtConsoleOnTime is zero and
prtConsoleOffTime is non-zero, the lamp is off. If
prtConsoleOffTime is zero and prtConsoleOnTime is non-zero,
the lamp is on. If both values are zero the status of the
lamp is undefined.
Additional information:
There are 2 control panel LEDs: Attention
and Ready. When an LED blinks, it is on for one half
second and off for one half second. The value used for this
object is 500 when the LED is off or blinking, otherwise it
is
zero.
When the LEDs are in a cycling state the value of this object
for all LEDs is zero and the value for prtConsoleOnTime for
all LEDs is zero."
::= { prtConsoleLightEntry 3 }
prtConsoleColor OBJECT-TYPE
SYNTAX INTEGER {
ePother(1),
ePunknown(2),
ePwhite(3),
ePred(4),
ePgreen(5),
ePblue(6),
ePcyan(7),
ePmagenta(8),
ePyellow(9),
ePorange(10)
}
ACCESS read-only
STATUS optional
DESCRIPTION "The color of this light."
::= { prtConsoleLightEntry 4 }
prtConsoleDescription OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..255))
ACCESS read-only
STATUS optional
DESCRIPTION "The vendor description or label of this light in the
localization specified by prtConsoleLocalization."
::= { prtConsoleLightEntry 5 }
END