-- EKINOPS-pmoailhc.TXT: MIB
|
||
--
|
||
--MIB Part Number:3MI00209AABE
|
||
--MIB Version:1
|
||
--
|
||
-- Copyright (c) 2016 by Ekinops
|
||
-- All rights reserved.
|
||
--
|
||
-- *****************************************************************
|
||
|
||
EKINOPS-PmOailhc-MIB DEFINITIONS ::= BEGIN
|
||
|
||
IMPORTS
|
||
ekinops,
|
||
EkiState,
|
||
EkiOnOff,
|
||
EkiMode,
|
||
EkiProtocol,
|
||
EkiApiState,
|
||
EkiSynchroMode,
|
||
EkiMeasureType
|
||
FROM EKINOPS-MIB
|
||
MODULE-IDENTITY,
|
||
OBJECT-TYPE,
|
||
NOTIFICATION-TYPE,
|
||
Unsigned32,
|
||
Integer32,
|
||
Counter32,
|
||
IpAddress
|
||
FROM SNMPv2-SMI
|
||
TEXTUAL-CONVENTION,
|
||
DisplayString
|
||
FROM SNMPv2-TC;
|
||
|
||
modulepmoailhc MODULE-IDENTITY
|
||
LAST-UPDATED "201605230000Z"
|
||
ORGANIZATION "Ekinops"
|
||
CONTACT-INFO
|
||
"Ekinops
|
||
|
||
3, rue Blaise Pascal
|
||
F-22300 Lannion / FRANCE
|
||
|
||
Tel : +33 (0)2 96 05 00 30
|
||
Fax : +33 (0)2 96 48 62 39
|
||
|
||
E-mail: support@ekinops.net"
|
||
DESCRIPTION
|
||
"Creation"
|
||
REVISION "201209100000Z"
|
||
DESCRIPTION
|
||
"Initial Version."
|
||
|
||
REVISION "201209100000Z"
|
||
DESCRIPTION
|
||
"Creation"
|
||
REVISION "201302080000Z"
|
||
DESCRIPTION
|
||
"Ext Pump alarms"
|
||
REVISION "201307020000Z"
|
||
DESCRIPTION
|
||
"Constant Gain function"
|
||
REVISION "201309160000Z"
|
||
DESCRIPTION
|
||
"Help change"
|
||
REVISION "201312020000Z"
|
||
DESCRIPTION
|
||
"External Pump Fail Insertion"
|
||
REVISION "201403260000Z"
|
||
DESCRIPTION
|
||
"Probcause,AlarmType - NMS completion"
|
||
REVISION "201412100000Z"
|
||
DESCRIPTION
|
||
"Labels cosmetic updates"
|
||
REVISION "201605230000Z"
|
||
DESCRIPTION
|
||
"New AlarmType – synthesisAlarm (12)"
|
||
::= { ekinops 55 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF LEVEL 2
|
||
--- *****************************************************
|
||
|
||
|
||
pmoailhcalarms OBJECT IDENTIFIER ::= { modulepmoailhc 2 }
|
||
pmoailhcAlmOther OBJECT IDENTIFIER ::= { pmoailhcalarms 1 }
|
||
pmoailhcAlmOtherNurg OBJECT IDENTIFIER ::= { pmoailhcAlmOther 1 }
|
||
pmoailhcAlmOtherUrg OBJECT IDENTIFIER ::= { pmoailhcAlmOther 2 }
|
||
pmoailhcAlmOtherCrit OBJECT IDENTIFIER ::= { pmoailhcAlmOther 3 }
|
||
|
||
pmoailhcAlmClient OBJECT IDENTIFIER ::= { pmoailhcalarms 2 }
|
||
pmoailhcAlmClientNurg OBJECT IDENTIFIER ::= { pmoailhcAlmClient 1 }
|
||
pmoailhcAlmClientUrg OBJECT IDENTIFIER ::= { pmoailhcAlmClient 2 }
|
||
pmoailhcAlmClientCrit OBJECT IDENTIFIER ::= { pmoailhcAlmClient 3 }
|
||
|
||
pmoailhcAlmLine OBJECT IDENTIFIER ::= { pmoailhcalarms 3 }
|
||
pmoailhcAlmLineNurg OBJECT IDENTIFIER ::= { pmoailhcAlmLine 1 }
|
||
pmoailhcAlmLineUrg OBJECT IDENTIFIER ::= { pmoailhcAlmLine 2 }
|
||
pmoailhcAlmLineCrit OBJECT IDENTIFIER ::= { pmoailhcAlmLine 3 }
|
||
|
||
|
||
pmoailhcmeasures OBJECT IDENTIFIER ::= { modulepmoailhc 3 }
|
||
pmoailhcMesrOther OBJECT IDENTIFIER ::= { pmoailhcmeasures 1 }
|
||
pmoailhcMesrClient OBJECT IDENTIFIER ::= { pmoailhcmeasures 2 }
|
||
pmoailhcMesrLine OBJECT IDENTIFIER ::= { pmoailhcmeasures 3 }
|
||
|
||
|
||
pmoailhccontrolsWrite OBJECT IDENTIFIER ::= { modulepmoailhc 6 }
|
||
pmoailhcCtrlOther OBJECT IDENTIFIER ::= { pmoailhccontrolsWrite 1 }
|
||
pmoailhcCtrlClient OBJECT IDENTIFIER ::= { pmoailhccontrolsWrite 2 }
|
||
pmoailhcCtrlLine OBJECT IDENTIFIER ::= { pmoailhccontrolsWrite 3 }
|
||
|
||
pmoailhcri OBJECT IDENTIFIER ::= { modulepmoailhc 7 }
|
||
|
||
|
||
pmoailhcConfig OBJECT IDENTIFIER ::= { modulepmoailhc 9 }
|
||
|
||
pmoailhctraps OBJECT IDENTIFIER ::= { modulepmoailhc 10 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- TEXTUAL-CONVENTION
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
PmoailhcpreampMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on OA preamp"
|
||
SYNTAX INTEGER {
|
||
oailhcpreampdefaultmode(0),
|
||
oailhcpreampconstantcurrentmode(1),
|
||
oailhcpreampconstantpowermode(2)
|
||
oailhcpreampconstantgainmode(3)
|
||
oailhcpreamppoutpinmode(4)
|
||
oailhcpreampmanualmode(5)
|
||
oailhcpreampfeedforwardmode(6)
|
||
oailhcpreamptransientsupmode(7)
|
||
|
||
}
|
||
|
||
PmoailhcboosterMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on OA booster"
|
||
SYNTAX INTEGER {
|
||
oailhcboosterdefaultmode(0),
|
||
oailhcboosterconstantcurrentmode(1),
|
||
oailhcboosterconstantpowermode(2)
|
||
oailhcboosterconstantgainmode(3)
|
||
oailhcboosterpoutpinmode(4)
|
||
oailhcboostermanualmode(5)
|
||
oailhcboosterfeedforwardmode(6)
|
||
oailhcboostertransientsupmode(7)
|
||
}
|
||
|
||
|
||
PmoailhcaprMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on APR"
|
||
SYNTAX INTEGER {
|
||
oailhcaproffmode(0),
|
||
oailhcaprsemiautomode(1),
|
||
oailhcaprautomode(2)
|
||
oailhcaprlossforwardingmode(3)
|
||
oailhcaprrepeatmode(4)
|
||
}
|
||
|
||
PmoailhcPreampGainAdjMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on Gain"
|
||
SYNTAX INTEGER {
|
||
oailhcpreampgainadjmanualmode(0),
|
||
oailhcpreampgainadjsemiautomode(1),
|
||
oailhcpreampgainadjautomode(2)
|
||
|
||
}
|
||
|
||
PmoailhcBoosterGainAdjMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes on Gain"
|
||
SYNTAX INTEGER {
|
||
oailhcboostergainadjmanualmode(0),
|
||
oailhcboostergainadjsemiautomode(1),
|
||
oailhcboostergainadjautomode(2)
|
||
|
||
}
|
||
|
||
|
||
PmoailhcPreampCstGainAdjMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes when constant Gain"
|
||
SYNTAX INTEGER {
|
||
oailhcpreampcstgainadjsemiautomode(1),
|
||
oailhcpreampcstgainadjautomode(2)
|
||
|
||
}
|
||
|
||
PmoailhcBoosterCstGainAdjMode ::= TEXTUAL-CONVENTION
|
||
STATUS current
|
||
DESCRIPTION "Different modes when constant Gain"
|
||
SYNTAX INTEGER {
|
||
oailhcboostercstgainadjsemiautomode(1),
|
||
oailhcboostercstgainadjautomode(2)
|
||
|
||
}
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- REMOTE INVENTORY
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
pmoailhcRinvReloadInventory OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Reload the inventory: This OID triggers an
|
||
inventory reload."
|
||
::= { pmoailhcri 2 }
|
||
|
||
pmoailhcRinvModulePlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Module platform description: This OID contains the
|
||
description of the Module."
|
||
::= { pmoailhcri 3 }
|
||
|
||
pmoailhcRinvSwPlatform OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"SW platform description: This OID contains the
|
||
description of the Software platform."
|
||
::= { pmoailhcri 4 }
|
||
|
||
pmoailhcRinvSwFoa OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Optical device driver description: This OID contains
|
||
the description of the driver of the optical devices
|
||
(Booster and Pre-Amp)"
|
||
::= { pmoailhcri 5 }
|
||
|
||
|
||
pmoailhcRinvInLine1Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmoailhcRinvInLine1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the InLine1s on the selected module"
|
||
::= { pmoailhcri 6 }
|
||
|
||
pmoailhcRinvInLine1Entry OBJECT-TYPE
|
||
SYNTAX PmoailhcRinvInLine1Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the InLine1s table"
|
||
INDEX { pmoailhcRinvInLine1Index }
|
||
::= { pmoailhcRinvInLine1Table 1 }
|
||
|
||
|
||
|
||
PmoailhcRinvInLine1Entry::=
|
||
SEQUENCE {
|
||
pmoailhcRinvInLine1Index
|
||
Integer32,
|
||
pmoailhcRinvInLine1
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmoailhcRinvInLine1Index OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for InLine1 table"
|
||
::= { pmoailhcRinvInLine1Entry 1 }
|
||
|
||
|
||
pmoailhcRinvInLine1 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the InLine1: This OID contains the inventory for the InLine1"
|
||
::= { pmoailhcRinvInLine1Entry 2 }
|
||
|
||
|
||
|
||
|
||
pmoailhcRinvInLine2Table OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmoailhcRinvInLine2Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"List of the InLine2 on the selected module"
|
||
::= { pmoailhcri 7 }
|
||
|
||
pmoailhcRinvInLine2Entry OBJECT-TYPE
|
||
SYNTAX PmoailhcRinvInLine2Entry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Row definition for the InLine2 table"
|
||
INDEX { pmoailhcRinvInLine2Index }
|
||
::= { pmoailhcRinvInLine2Table 1 }
|
||
|
||
|
||
|
||
PmoailhcRinvInLine2Entry::=
|
||
SEQUENCE {
|
||
pmoailhcRinvInLine2Index
|
||
Integer32,
|
||
pmoailhcRinvInLine2
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmoailhcRinvInLine2Index OBJECT-TYPE
|
||
SYNTAX Integer32(1..16)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Index for InLine2 table"
|
||
::= { pmoailhcRinvInLine2Entry 1 }
|
||
|
||
|
||
pmoailhcRinvInLine2 OBJECT-TYPE
|
||
SYNTAX DisplayString
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Inventory for the InLine2: This OID contains the inventory for the InLine2"
|
||
::= { pmoailhcRinvInLine2Entry 2 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- ALARMS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm0 article
|
||
--- *****************************************************
|
||
pmoailhcAlmsynthAlm0 OBJECT IDENTIFIER ::= { pmoailhcAlmOtherCrit 0 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmDefFuseB OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse B Fail :This OID indicates
|
||
that the fuse of the power input
|
||
B is in fail condition <Help>
|
||
Status of the Fuse B <Condtype>
|
||
DEF_FUSE_B <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 16 }
|
||
|
||
|
||
|
||
pmoailhcAlmDefFuseA OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Fuse A Fail :This OID indicates
|
||
that the fuse of the power input
|
||
A is in fail condition <Help>
|
||
Status of the Fuse A <Condtype>
|
||
DEF_FUSE_A <Probcause> powerProblem
|
||
(36) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 15 }
|
||
|
||
|
||
|
||
pmoailhcAlmExtPump2NotLocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
External Pump2 Not Detected :This
|
||
OID indicates that the second external
|
||
pump is not detected by the amplifier
|
||
module <Help> This alarm indicates
|
||
if the second external pump is
|
||
detected by the amplifier module
|
||
<Condtype> EXT_PUMP2_NOT_LOCKED
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 13 }
|
||
|
||
|
||
|
||
pmoailhcAlmExtPump1NotLocked OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
External Pump1 Not Detected :This
|
||
OID indicates that the first external
|
||
pump is not detected by the amplifier
|
||
module <Help> This alarm indicates
|
||
if the first external pump is detected
|
||
by the amplifier module <Condtype>
|
||
EXT_PUMP1_NOT_LOCKED <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 12 }
|
||
|
||
|
||
|
||
pmoailhcAlmDwEdfaInitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Not Initialized :This OID
|
||
indicates that the initialisation
|
||
of the IL2 is not completed <Help>
|
||
This status indicates if the IL2
|
||
has been correctly initialized
|
||
<Condtype> DW_EDFA_INIT_NOT_COMPL
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 11 }
|
||
|
||
|
||
|
||
pmoailhcAlmUpEdfaInitNotCompl OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Not Initialized :This OID
|
||
indicates that the initialisation
|
||
of the IL1 is not completed <Help>
|
||
This status indicates if the IL1
|
||
has been correctly initialized
|
||
<Condtype> UP_EDFA_INIT_NOT_COMPL
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 10 }
|
||
|
||
|
||
|
||
pmoailhcAlmModGlobFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Failure :This OID is set
|
||
on detection of a failure originating
|
||
from the PM <Condtype> MOD_GLOB_FAIL
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 9 }
|
||
|
||
|
||
|
||
pmoailhcAlmAprOn OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Automatic Power Reduction :This
|
||
OID indicates that the APR algorithm
|
||
has been operated and the output
|
||
of the lasers are shutdown <Help>
|
||
The APR algorithm has been completed
|
||
<Condtype> APR_ON <Probcause>
|
||
other (1) <Alarmtype> other (1)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 2 }
|
||
|
||
|
||
|
||
pmoailhcAlmMaintenanceMode OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Maintenance Mode :This OID indicates
|
||
that the PM is in maintenance mode
|
||
<Help> This status indiates if
|
||
the module is currently in maintenance
|
||
mode <Condtype> MAINTENANCE_MODE
|
||
<Probcause> other (1) <Alarmtype>
|
||
other (1) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm2 article
|
||
--- *****************************************************
|
||
pmoailhcAlmsynthAlm2 OBJECT IDENTIFIER ::= { pmoailhcAlmOtherNurg 2 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmConfTableLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Load :This OID
|
||
is at 1 during the loading of
|
||
configuration tables in the modules
|
||
RAM. <Condtype> CONF_TABLE_LOAD
|
||
<Probcause> bandwidthReduced(4)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm2 3 }
|
||
|
||
|
||
|
||
pmoailhcAlmInvUpload OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Inventory Upload :This OID is
|
||
at 1 during the uploading of PM
|
||
inventory information. <Condtype>
|
||
INV_UPLOAD <Probcause> bandwidthReduced(4)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm2 2 }
|
||
|
||
|
||
|
||
pmoailhcAlmConfTableSave OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Configuration Save :This OID
|
||
is at 1 during the saving of a
|
||
new configuration table in the
|
||
module Flash memory. <Condtype>
|
||
CONF_TABLE_SAVE <Probcause> bandwidthReduced(4)
|
||
<Alarmtype> other (1) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm7 article
|
||
--- *****************************************************
|
||
pmoailhcAlmsynthAlm7 OBJECT IDENTIFIER ::= { pmoailhcAlmLineCrit 7 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmLineExtPumpFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 External Pump Fail :This OID
|
||
indicates that the external pump
|
||
linked to the IL1 is in fail condition
|
||
<Help> This alarm indicates
|
||
if the external pump linked to
|
||
the IL1 is in fail condition <Condtype>
|
||
LINE_EXT_PUMP_FAIL <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm7 13 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port Failure :This OID indicates
|
||
a failure on the line port <Condtype>
|
||
LINE_FAIL <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm7 12 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineDdmAlm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Line Optical Module DDM
|
||
:This OID indicates an alarm is
|
||
present coming out of Line optical
|
||
interface DDM <Condtype> LINE_DDM_ALM
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm7 10 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineDdmWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Line Optical Module
|
||
DDM :This OID indicates a warning
|
||
is present coming out of Line optical
|
||
interface DDM <Condtype> LINE_DDM_WARNING
|
||
<Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm7 9 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineTxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Optical Output Shutdown :This
|
||
OID indicates the IL1 optical output
|
||
power is on <Help> This status
|
||
indicates if the IL1 laser pump
|
||
is ON or OFF <Condtype> LINE_TX_OFF
|
||
<Probcause> other (1) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm7 5 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineHwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Line Port HW Failure :This OID
|
||
indicates a failure on line port,
|
||
most probably caused by a HW issue
|
||
<Condtype> LINE_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm7 4 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synthAlm8 article
|
||
--- *****************************************************
|
||
pmoailhcAlmsynthAlm8 OBJECT IDENTIFIER ::= { pmoailhcAlmClientCrit 8 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmClientExtPumpFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 External Pump Fail :This OID
|
||
indicates that first external pump
|
||
linked to the IL2 is in fail condition
|
||
<Help> This alarm indicates
|
||
if the external pump linked to
|
||
the IL2 is in fail condition <Condtype>
|
||
CLIENT_EXT_PUMP_FAIL <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm8 13 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Client Port Failure :This OID
|
||
indicates a failure on the Client
|
||
port <Condtype> CLIENT_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm8 12 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientDdmAlm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Alarm On Client Optical Module
|
||
DDM :This OID indicates an alarm
|
||
is present coming out of Client
|
||
optical interface DDM <Condtype>
|
||
CLIENT_DDM_ALM <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> synthesisAlarm
|
||
(12) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm8 10 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientDdmWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Warning On Client Optical Module
|
||
DDM :This OID indicates a warning
|
||
is present coming out of Client
|
||
optical interface DDM <Condtype>
|
||
CLIENT_DDM_WARNING <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm8 9 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientTxOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Optical Output Shutdown :This
|
||
OID indicates the IL2 optical output
|
||
power is on <Help> This status
|
||
indicates if the IL2 laser pump
|
||
transceiver laser is ON or OFF
|
||
<Condtype> CLIENT_TX_OFF <Probcause>
|
||
other (1) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm8 5 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientHwFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Client Port HW Failure :This OID
|
||
indicates a failure on Client port,
|
||
most probably caused by a HW issue
|
||
<Condtype> CLIENT_HW_FAIL <Probcause>
|
||
equipmentMalfunction (16) <Alarmtype>
|
||
synthesisAlarm (12) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmsynthAlm8 4 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaAlarms1 article
|
||
--- *****************************************************
|
||
pmoailhcAlmclientEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoailhcAlmClientUrg 32 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmClientBiasHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Bias High Alarm :This OID
|
||
indicates that the Bias is higher
|
||
than the alarm theshold of the
|
||
IL2 Optical Module <Help> This
|
||
alarm indicates if the IL2 bias
|
||
is too high <Condtype> CLIENT_BIAS_HIGH_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms1 8 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientBiasLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Bias Low Alarm :This OID indicates
|
||
that the Bias is lower than the
|
||
alarm theshold of the IL2 Optical
|
||
Module <Help> This alarm indicates
|
||
if the IL2 bias is too low <Condtype>
|
||
CLIENT_BIAS_LOW_ALARM <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms1 7 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientOutputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Tx Pwr High Alarm :This OID
|
||
indicates that the Transmit Power
|
||
is higher than the alarm theshold
|
||
of the IL2 Optical Module <Help>
|
||
This alarm indicates if the IL2
|
||
tx power is too high <Condtype>
|
||
CLIENT_OUTPUT_PWR_HIGH_ALARM <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms1 6 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientOutputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Tx Pwr Low Alarm :This OID
|
||
indicates that the Transmit Power
|
||
is lower than the alarm theshold
|
||
of the IL2 Optical Module <Help>
|
||
This alarm indicates if the IL2
|
||
tx power is too low <Condtype>
|
||
CLIENT_OUTPUT_PWR_LOW_ALARM <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms1 5 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientInputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Rx Pwr High Alarm :This OID
|
||
indicates that the Receive Power
|
||
is higher than the alarm theshold
|
||
of the IL1 Optical Module <Help>
|
||
This alarm indicates if the IL1
|
||
rx power is too high <Condtype>
|
||
CLIENT_INPUT_PWR_HIGH_ALARM <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms1 4 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientInputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Rx Pwr Low Alarm :This OID
|
||
indicates that the Receive Power
|
||
is lower than the alarm theshold
|
||
of the IL1 Optical Module <Help>
|
||
This alarm indicates if the IL1
|
||
rx power is too low <Condtype>
|
||
CLIENT_INPUT_PWR_LOW_ALARM <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms1 3 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientGainHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Gain High Alarm :This OID
|
||
indicates that the Gain is higher
|
||
than the alarm threshold of the
|
||
IL2 Module <Help> This alarm
|
||
indicates if the IL2 gain is too
|
||
high <Condtype> CLIENT_GAIN_HIGH_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms1 2 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientGainLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Gain Low Alarm :This OID indicates
|
||
that the Gain is lower than the
|
||
alarm theshold of the IL2 Module
|
||
<Help> This alarm indicates if
|
||
the IL2 gain is too low <Condtype>
|
||
CLIENT_GAIN_LOW_ALARM <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaWarnings article
|
||
--- *****************************************************
|
||
pmoailhcAlmclientEdfaWarnings OBJECT IDENTIFIER ::= { pmoailhcAlmClientNurg 33 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmClientBiasHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Bias High Warning :This OID
|
||
indicates that the Bias is higher
|
||
than the Warning theshold of the
|
||
IL2 Optical Module <Help> This
|
||
warning indicates if the IL2 bias
|
||
is too high <Condtype> CLIENT_BIAS_HIGH_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaWarnings 8 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientBiasLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Bias Low Warning :This OID
|
||
indicates that the Bias is lower
|
||
than the Warning theshold of the
|
||
IL2 Optical Module <Help> This
|
||
warning indicates if the IL2 bias
|
||
is too low <Condtype> CLIENT_BIAS_LOW_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaWarnings 7 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientOutputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Tx Pwr High Warning :This
|
||
OID indicates that the Transmit
|
||
Power is higher than the Warning
|
||
theshold of the IL2 Optical Module
|
||
<Help> This warning indicates
|
||
if the IL2 tx power is too high
|
||
<Condtype> CLIENT_OUTPUT_PWR_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaWarnings 6 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientOutputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Tx Pwr Low Warning :This OID
|
||
indicates that the Transmit Power
|
||
is lower than the Warning theshold
|
||
of the IL2 Optical Module <Help>
|
||
This warning indicates if the
|
||
IL2 tx power is too low <Condtype>
|
||
CLIENT_OUTPUT_PWR_LOW_WARNING <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaWarnings 5 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientInputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Rx Pwr High Warning :This
|
||
OID indicates that the Receive
|
||
Power is higher than the Warning
|
||
theshold of the IL1 Optical Module
|
||
<Help> This warning indicates
|
||
if the IL1 rx power is too high
|
||
<Condtype> CLIENT_INPUT_PWR_HIGH_WARNING
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaWarnings 4 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientInputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Rx Pwr Low Warning :This OID
|
||
indicates that the Receive Power
|
||
is lower than the Warning theshold
|
||
of the IL1 Optical Module <Help>
|
||
This warning indicates if the
|
||
IL1 rx power is too low <Condtype>
|
||
CLIENT_INPUT_PWR_LOW_WARNING <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaWarnings 3 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientGainHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Gain High Warning :This OID
|
||
indicates that the Gain is higher
|
||
than the Warning threshold of the
|
||
IL2 Module <Help> This alarm
|
||
indicates if the IL2 gain is too
|
||
high <Condtype> CLIENT_GAIN_HIGH_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaWarnings 2 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientGainLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Gain Low Warning :This OID
|
||
indicates that the Gain is lower
|
||
than the Warning theshold of the
|
||
IL2 Module <Help> This alarm
|
||
indicates if the IL2 gain is too
|
||
low <Condtype> CLIENT_GAIN_LOW_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaWarnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaAlarms2 article
|
||
--- *****************************************************
|
||
pmoailhcAlmclientEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoailhcAlmClientCrit 35 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmClientExtPumpEdfaLowCurrent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Pump Low Current :This OID
|
||
indicates that the EDFA pump current
|
||
of IL2 is too low because of the
|
||
external pump high power<Help>
|
||
This alarm (only active when
|
||
there is at least on external
|
||
pump) indicates that the EDFA
|
||
pump current of the IL2 is too
|
||
low because of the external pump
|
||
high power. <Condtype> CLIENT_EXT_PUMP_EDFA_LOW_CURRENT
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms2 5 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientEdfaLos OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Loss Of Signal :This OID indicates
|
||
a Loss of Signal on the IL1 Optical
|
||
Module <Help> This alarm indicates
|
||
if an optical signal is detected
|
||
on the IL1 input <Condtype> CLIENT_EDFA_LOS
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> physicalViolation (9)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms2 4 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientEdfaLaserFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Pump Laser Fail :This OID
|
||
indicates a Transmit Laser Fail
|
||
on the IL2 Optical Module <Help>
|
||
This alarm indicates if the laser
|
||
of the IL2 is in fail condition
|
||
<Condtype> CLIENT_EDFA_LASER_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms2 3 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientEdfaTecFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 TEC Fail :This OID indicates
|
||
that the TEC is in fail condition
|
||
on the IL2 Optical Module <Help>
|
||
This alarm indicates if the TEC
|
||
of the IL2 is in fail condition
|
||
<Condtype> CLIENT_EDFA_TEC_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms2 2 }
|
||
|
||
|
||
|
||
pmoailhcAlmClientEdfaNr OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Optical Module Not Ready :This
|
||
OID indicates that the IL2 Optical
|
||
Module is not ready <Help> This
|
||
status indicates if the IL2 has
|
||
been correctly initialized <Condtype>
|
||
CLIENT_EDFA_NR <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmclientEdfaAlarms2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaAlarms1 article
|
||
--- *****************************************************
|
||
pmoailhcAlmlineEdfaAlarms1 OBJECT IDENTIFIER ::= { pmoailhcAlmLineUrg 40 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmLineBiasHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Bias High Alarm :This OID
|
||
indicates that the Bias is higher
|
||
than the alarm theshold of the
|
||
IL1 Optical Module <Help> This
|
||
alarm indicates if the IL1 bias
|
||
is too high <Condtype> LINE_BIAS_HIGH_ALARM
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms1 8 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineBiasLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Bias Low Alarm :This OID indicates
|
||
that the Bias is lower than the
|
||
alarm theshold of the IL1 Optical
|
||
Module <Help> This alarm indicates
|
||
if the IL1 bias is too low <Condtype>
|
||
LINE_BIAS_LOW_ALARM <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms1 7 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineOutputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Tx Pwr High Alarm :This OID
|
||
indicates that the Transmit Power
|
||
is higher than the alarm theshold
|
||
of the IL1 Optical Module <Help>
|
||
This alarm indicates if the IL1
|
||
tx power is too high <Condtype>
|
||
LINE_OUTPUT_PWR_HIGH_ALARM <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms1 6 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineOutputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Tx Pwr Low Alarm :This OID
|
||
indicates that the Transmit Power
|
||
is lower than the alarm theshold
|
||
of the IL1 Optical Module <Help>
|
||
This alarm indicates if the IL1
|
||
tx power is too low <Condtype>
|
||
LINE_OUTPUT_PWR_LOW_ALARM <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms1 5 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineInputPwrHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Rx Pwr High Alarm :This OID
|
||
indicates that the Receive Power
|
||
is higher than the alarm theshold
|
||
of the IL2 Optical Module <Help>
|
||
This alarm indicates if the IL2
|
||
rx power is too high <Condtype>
|
||
LINE_INPUT_PWR_HIGH_ALARM <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms1 4 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineInputPwrLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Rx Pwr Low Alarm :This OID
|
||
indicates that the Receive Power
|
||
is lower than the alarm theshold
|
||
of the IL2 Optical Module <Help>
|
||
This alarm indicates if the IL2
|
||
rx power is too low <Condtype>
|
||
LINE_INPUT_PWR_LOW_ALARM <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms1 3 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineGainHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Gain High Alarm :This OID
|
||
indicates that the Gain is higher
|
||
than the alarm threshold of the
|
||
IL1 Module <Help> This alarm
|
||
indicates if the IL1 gain is too
|
||
high <Condtype> LINE_GAIN_HIGH_ALARM
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms1 2 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineGainLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Gain Low Alarm :This OID indicates
|
||
that the Gain is lower than the
|
||
alarm theshold of the IL1 Module
|
||
<Help> This alarm indicates if
|
||
the IL1 gain is too low <Condtype>
|
||
LINE_GAIN_LOW_ALARM <Probcause>
|
||
performanceDegraded (35) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms1 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaWarnings article
|
||
--- *****************************************************
|
||
pmoailhcAlmlineEdfaWarnings OBJECT IDENTIFIER ::= { pmoailhcAlmLineNurg 41 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmLineBiasHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Bias High Warning :This OID
|
||
indicates that the Bias is higher
|
||
than the Warning theshold of the
|
||
IL1 Optical Module <Help> This
|
||
warning indicates if the IL1 bias
|
||
is too high <Condtype> LINE_BIAS_HIGH_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaWarnings 8 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineBiasLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Bias Low Warning :This OID
|
||
indicates that the Bias is lower
|
||
than the Warning theshold of the
|
||
IL1 Optical Module <Help> This
|
||
warning indicates if the IL1 bias
|
||
is too low <Condtype> LINE_BIAS_LOW_WARNING
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaWarnings 7 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineOutputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Tx Pwr High Warning :This
|
||
OID indicates that the Transmit
|
||
Power is higher than the Warning
|
||
theshold of the IL1 Optical Module
|
||
<Help> This warning indicates
|
||
if the IL1 tx power is too high
|
||
<Condtype> LINE_OUTPUT_PWR_HIGH_WARNING
|
||
<Probcause> transmitterFailure
|
||
(56) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaWarnings 6 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineOutputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Tx Pwr Low Warning :This OID
|
||
indicates that the Transmit Power
|
||
is lower than the Warning theshold
|
||
of the IL1 Optical Module <Help>
|
||
This warning indicates if the
|
||
IL1 tx power is too low <Condtype>
|
||
LINE_OUTPUT_PWR_LOW_WARNING <Probcause>
|
||
transmitterFailure (56) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaWarnings 5 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineInputPwrHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Rx Pwr High Warning :This
|
||
OID indicates that the Receive
|
||
Power is higher than the Warning
|
||
theshold of the IL2 Optical Module
|
||
<Help> This warning indicates
|
||
if the IL2 rx power is too high
|
||
<Condtype> LINE_INPUT_PWR_HIGH_WARNING
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> equipmentAlarm (5)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaWarnings 4 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineInputPwrLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Rx Pwr Low Warning :This OID
|
||
indicates that the Receive Power
|
||
is lower than the Warning theshold
|
||
of the IL2 Optical Module <Help>
|
||
This warning indicates if the
|
||
IL2 rx power is too low <Condtype>
|
||
LINE_INPUT_PWR_LOW_WARNING <Probcause>
|
||
receiveFailure (41) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaWarnings 3 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineGainHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Gain High Warning :This OID
|
||
indicates that the Gain is higher
|
||
than the Warning threshold of the
|
||
IL1 Module <Help> This alarm
|
||
indicates if the IL1 gain is too
|
||
high <Condtype> LINE_GAIN_HIGH_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaWarnings 2 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineGainLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Gain Low Warning :This OID
|
||
indicates that the Gain is lower
|
||
than the Warning theshold of the
|
||
IL1 Module <Help> This alarm
|
||
indicates if the IL1 gain is too
|
||
low <Condtype> LINE_GAIN_LOW_WARNING
|
||
<Probcause> performanceDegraded
|
||
(35) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaWarnings 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaAlarms2 article
|
||
--- *****************************************************
|
||
pmoailhcAlmlineEdfaAlarms2 OBJECT IDENTIFIER ::= { pmoailhcAlmLineCrit 43 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmLineExtPumpEdfaLowCurrent OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Pump Low Current :This OID
|
||
indicates that the EDFA pump current
|
||
of IL1 is too low because of the
|
||
external pump high power<Help>
|
||
This alarm (only active when
|
||
there is at least on external
|
||
pump) indicates that the EDFA
|
||
pump current of the IL1 is too
|
||
low because of the external pump
|
||
high power. <Condtype> LINE_EXT_PUMP_EDFA_LOW_CURRENT
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity>
|
||
(2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms2 5 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineEdfaLos OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Loss Of Signal :This OID indicates
|
||
a Loss of Signal on the IL2 Optical
|
||
Module <Help> This alarm indicates
|
||
if an optical signal is detected
|
||
on the IL2 input <Condtype> LINE_EDFA_LOS
|
||
<Probcause> receiveFailure (41)
|
||
<Alarmtype> physicalViolation (9)
|
||
<Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms2 4 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineEdfaLaserFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Pump Laser Fail :This OID
|
||
indicates a Transmit Laser Fail
|
||
on the IL1 Optical Module <Help>
|
||
This alarm indicates if the laser
|
||
of the IL1 is in fail condition
|
||
<Condtype> LINE_EDFA_LASER_FAIL
|
||
<Probcause> pumpFailure (39) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms2 3 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineEdfaTecFail OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 TEC Fail :This OID indicates
|
||
that the TEC is in fail condition
|
||
on the IL1 Optical Module <Help>
|
||
This alarm indicates if the TEC
|
||
of the IL1 is in fail condition
|
||
<Condtype> LINE_EDFA_TEC_FAIL <Probcause>
|
||
pumpFailure (39) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms2 2 }
|
||
|
||
|
||
|
||
pmoailhcAlmLineEdfaNr OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Optical Module Not Ready :This
|
||
OID indicates that the IL1 Optical
|
||
Module is not ready <Help> This
|
||
status indicates if the IL1 has
|
||
been correctly initialized <Condtype>
|
||
LINE_EDFA_NR <Probcause> equipmentMalfunction
|
||
(16) <Alarmtype> equipmentAlarm
|
||
(5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmlineEdfaAlarms2 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the foaAlarms article
|
||
--- *****************************************************
|
||
pmoailhcAlmfoaAlarms OBJECT IDENTIFIER ::= { pmoailhcAlmOtherUrg 74 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmTempHighAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Temperature High Alarm :This OID
|
||
indicates that the PM temperature
|
||
is higher than the alarm threshold
|
||
<Condtype> TEMP_HIGH_ALARM <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmfoaAlarms 8 }
|
||
|
||
|
||
|
||
pmoailhcAlmTermpLowAlarm OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Temperature Low Alarm :This OID
|
||
indicates that the PM temperature
|
||
if lower than the alarm threshold
|
||
<Condtype> TERMP_LOW_ALARM <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmfoaAlarms 7 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the foaWarnings article
|
||
--- *****************************************************
|
||
pmoailhcAlmfoaWarnings OBJECT IDENTIFIER ::= { pmoailhcAlmOtherNurg 75 }
|
||
|
||
|
||
|
||
|
||
pmoailhcAlmTempHighWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Temperature High Warning :This
|
||
OID indicates that the PM temperature
|
||
if higher than the Warning threshold
|
||
<Condtype> TEMP_HIGH_WARNING <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmfoaWarnings 8 }
|
||
|
||
|
||
|
||
pmoailhcAlmTermpLowWarning OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Temperature Low Warning :This
|
||
OID indicates that the PM temperature
|
||
if lower than the Warning threshold
|
||
<Condtype> TERMP_LOW_WARNING <Probcause>
|
||
temperatureUnacceptable (51) <Alarmtype>
|
||
equipmentAlarm (5) <Polarity> (2)
|
||
"
|
||
::= { pmoailhcAlmfoaWarnings 7 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONTROLS
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the synth0 article
|
||
--- *****************************************************
|
||
pmoailhcCtrlsynth0 OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 0 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlConfClear OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Clear Configuration Tables :This
|
||
bit clears the configuration tables
|
||
from configuration in the flash.
|
||
<Help> This control restores
|
||
the default configuration of the
|
||
module
|
||
"
|
||
::= { pmoailhcCtrlsynth0 13 }
|
||
|
||
|
||
|
||
pmoailhcCtrlConfFlash OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Write Configuration Tables :This
|
||
bit saves the current configuration
|
||
of the module as configuration
|
||
in the flash. <Help> This control
|
||
saves the customer configuration
|
||
on the module
|
||
"
|
||
::= { pmoailhcCtrlsynth0 9 }
|
||
|
||
|
||
|
||
pmoailhcCtrlConfLoad OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Load Configuration Tables :When
|
||
set this enables loading from flash
|
||
configuration1 into the module.
|
||
"
|
||
::= { pmoailhcCtrlsynth0 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the swMgnt article
|
||
--- *****************************************************
|
||
pmoailhcCtrlswMgnt OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 5 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlWarmReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Warm Reset :This OID, when
|
||
set, causes a warm reset of the
|
||
Software. This reset is not traffic
|
||
affecting, and the configuration
|
||
of the Sofwtare remains unchanged.
|
||
<Help> This control initiates
|
||
a warm reset of the module.
|
||
"
|
||
::= { pmoailhcCtrlswMgnt 3 }
|
||
|
||
|
||
|
||
pmoailhcCtrlColdReset OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Cold Reset :This OID, when
|
||
set, causes a cold reset of the
|
||
Software. This reset is traffic
|
||
affecting, and the configuration
|
||
of Software is reloaded on start-up.
|
||
<Help> This control initiates
|
||
a cold reset of the module.
|
||
"
|
||
::= { pmoailhcCtrlswMgnt 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaLaserOff article
|
||
--- *****************************************************
|
||
pmoailhcCtrlclientEdfaLaserOff OBJECT IDENTIFIER ::= { pmoailhcCtrlClient 32 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlClientEdfaLaserOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Optical Module Laser Off :This
|
||
OID switches OFF the laser of the
|
||
IL2li Optical Module <Help> This
|
||
control defines the laser state
|
||
of the IL2
|
||
"
|
||
::= { pmoailhcCtrlclientEdfaLaserOff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientGainCstMonitorValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrlclientGainCstMonitorValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Fiber Aging Period :This OID
|
||
sets the value of the monitoring
|
||
period to detect a fiber aging.
|
||
(Unit = s) This value sets the
|
||
monitoring period to detect a
|
||
fiber aging.
|
||
"
|
||
::= { pmoailhcCtrlClient 34 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientGainCstPoutValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrlclientGainCstPoutValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Ref Pout :This OID sets the
|
||
value of the reference output power
|
||
used to compensate the fiber aging
|
||
(active only in constant gain
|
||
mode) (AV=(Gain/0,005) + 32768)
|
||
(Unit = dBm) <Help> This value
|
||
defines the reference output power
|
||
used to compensate the fiber aging
|
||
"
|
||
::= { pmoailhcCtrlClient 35 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientGainSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrlclientGainSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Gain Target :This OID sets
|
||
the value of the nominal gain of
|
||
the IL2 Module (active only in
|
||
constant output power mode) (AV=(Gain/0,005)
|
||
+ 32768) (Unit = dB) <Help> This
|
||
control sets the value of the nominal
|
||
gain of the IL2 Module (active
|
||
only in constant output power
|
||
mode)
|
||
"
|
||
::= { pmoailhcCtrlClient 36 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientGainProcessing article
|
||
--- *****************************************************
|
||
pmoailhcCtrlclientGainProcessing OBJECT IDENTIFIER ::= { pmoailhcCtrlClient 37 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlClientGainProc OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Gain Adjustment :<Help> This
|
||
control initiates the automatic
|
||
nominal gain adjustment on the
|
||
IL2 Module<Help> This control
|
||
initiates the automatic nominal
|
||
gain adjustment on the IL2 Module
|
||
"
|
||
::= { pmoailhcCtrlclientGainProcessing 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientGainCstFiberAgingMarginValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrlclientGainCstFiberAgingMarginValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Aging Threshold :This OID
|
||
sets the threshold to consider
|
||
the power drop as a fiber aging.
|
||
(active only in constant gain mode)
|
||
(AV=(Gain/0,005) + 32768) (Unit
|
||
= dB) <Help> This value defines
|
||
the threshold to consider the power
|
||
drop as a fiber aging.
|
||
"
|
||
::= { pmoailhcCtrlClient 38 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientGainCstAdddropMarginValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrlclientGainCstAdddropMarginValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 AddDrop Threshold :This OID
|
||
sets the threshold to not consider
|
||
the power drop as a fiber aging.
|
||
(active only in constant gain
|
||
mode) (AV=(Gain/0,005) + 32768)
|
||
(Unit = dB) <Help> This value defines
|
||
the threshold to not consider the
|
||
power drop as a fiber aging.
|
||
"
|
||
::= { pmoailhcCtrlClient 39 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaLaserOff article
|
||
--- *****************************************************
|
||
pmoailhcCtrllineEdfaLaserOff OBJECT IDENTIFIER ::= { pmoailhcCtrlLine 40 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlLineEdfaLaserOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Optical Module Laser Off :This
|
||
OID switches OFF the laser of the
|
||
IL1 Optical Module <Help> This
|
||
control defines the laser state
|
||
of the IL1
|
||
"
|
||
::= { pmoailhcCtrllineEdfaLaserOff 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineGainCstMonitorValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrllineGainCstMonitorValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Fiber Aging Period :This OID
|
||
sets the value of the monitoring
|
||
period to detect a fiber aging.
|
||
(Unit = s) This value sets the
|
||
monitoring period to detect a
|
||
fiber aging.
|
||
"
|
||
::= { pmoailhcCtrlLine 42 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineGainCstPoutValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrllineGainCstPoutValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Ref Pout :This OID sets the
|
||
value of the reference output power
|
||
used to compensate the fiber aging
|
||
(active only in constant gain
|
||
mode) (AV=(Gain/0,005) + 32768)
|
||
(Unit = dBm) <Help> This value
|
||
defines the reference output power
|
||
used to compensate the fiber aging
|
||
"
|
||
::= { pmoailhcCtrlLine 43 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineGainSettingValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrllineGainSettingValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Gain Target :This OID sets
|
||
the value of the nominal gain of
|
||
the IL1 Module (active only in
|
||
constant output power mode) (AV=(Gain/0,005)
|
||
+ 32768) (Unit = dB) <Help> This
|
||
control sets the value of the nominal
|
||
gain of the IL1 Module (active
|
||
only in constant output power
|
||
mode)
|
||
"
|
||
::= { pmoailhcCtrlLine 44 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineGainProcessing article
|
||
--- *****************************************************
|
||
pmoailhcCtrllineGainProcessing OBJECT IDENTIFIER ::= { pmoailhcCtrlLine 45 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlLineGainProc OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Gain Adjustment :This OID
|
||
initiates the automatic nominal
|
||
gain adjustment on the IL1 Module<Help>
|
||
This control initiates the automatic
|
||
nominal gain adjustment on the
|
||
IL1 Module
|
||
"
|
||
::= { pmoailhcCtrllineGainProcessing 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineGainCstFiberAgingMarginValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrllineGainCstFiberAgingMarginValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Aging Threshold :This OID
|
||
sets the threshold to consider
|
||
the power drop as a fiber aging.
|
||
(active only in constant gain mode)
|
||
(AV=(Gain/0,005) + 32768) (Unit
|
||
= dB) <Help> This value defines
|
||
the threshold to consider the power
|
||
drop as a fiber aging.
|
||
"
|
||
::= { pmoailhcCtrlLine 46 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineGainCstAdddropMarginValue article
|
||
--- *****************************************************
|
||
|
||
pmoailhcCtrllineGainCstAdddropMarginValue OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 AddDrop Threshold :This OID
|
||
sets the threshold to not consider
|
||
the power drop as a fiber aging.
|
||
(active only in constant gain
|
||
mode) (AV=(Gain/0,005) + 32768)
|
||
(Unit = dB) <Help> This value defines
|
||
the threshold to not consider the
|
||
power drop as a fiber aging.
|
||
"
|
||
::= { pmoailhcCtrlLine 47 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the ledTest article
|
||
--- *****************************************************
|
||
pmoailhcCtrlledTest OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 73 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlLedOff OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Leds Off :This OID switches off
|
||
all the Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to OFF
|
||
"
|
||
::= { pmoailhcCtrlledTest 3 }
|
||
|
||
|
||
|
||
pmoailhcCtrlRedLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Red Leds Test :This OID switches
|
||
on all the red Leds as a test feature.
|
||
<Help> This control initiates
|
||
a test leds turning all the LEDs
|
||
to red
|
||
"
|
||
::= { pmoailhcCtrlledTest 2 }
|
||
|
||
|
||
|
||
pmoailhcCtrlGreenLed OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Green Leds Test :This OID switches
|
||
on all the green Leds as a test
|
||
feature. <Help> This control
|
||
initiates a test leds turning
|
||
all the LEDs to green
|
||
"
|
||
::= { pmoailhcCtrlledTest 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the maintMode article
|
||
--- *****************************************************
|
||
pmoailhcCtrlmaintMode OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 75 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlMaintenance OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
PM Maintenance Mode :This OID
|
||
sets the PM in maintenance mode
|
||
<Help> This control enables the
|
||
maintenance mode of the module
|
||
"
|
||
::= { pmoailhcCtrlmaintMode 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the aprRestart article
|
||
--- *****************************************************
|
||
pmoailhcCtrlaprRestart OBJECT IDENTIFIER ::= { pmoailhcCtrlOther 76 }
|
||
|
||
|
||
|
||
|
||
pmoailhcCtrlAprManualRestart OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
APR Manual Restart :This OID initiates
|
||
the Restart mechanism to retrieve
|
||
from the APR state.<Help> This
|
||
control initiates the Restart
|
||
mechanism to retrieve from the
|
||
APR state.
|
||
"
|
||
::= { pmoailhcCtrlaprRestart 1 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- MEASURES
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaBiasMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrclientEdfaBiasMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Pump Laser Current :This OID
|
||
gives the pump laser current of
|
||
the IL2 Optical Module (Current
|
||
=AV/100) (Unit = mA) <Help> This
|
||
measure gives the bias of the IL2
|
||
pump laser
|
||
"
|
||
::= { pmoailhcMesrClient 32 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaTxpwrMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrclientEdfaTxpwrMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Tx Power :This OID gives the
|
||
transmit power value of the IL2
|
||
Optical Module (Power =(AV-32768)*0,005)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Tx optical power of the
|
||
IL2
|
||
"
|
||
::= { pmoailhcMesrClient 33 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaRxpwrMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrclientEdfaRxpwrMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Rx Power :This OID gives the
|
||
receive power value of the IL1
|
||
Optical Module (Power =(AV-32768)*0,005)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Rx optical power of the
|
||
IL1
|
||
"
|
||
::= { pmoailhcMesrClient 34 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientEdfaGainMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrclientEdfaGainMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Gain Target :This OID gives
|
||
the gain value of the IL2 Module
|
||
(Gain =(AV-32768)*0,005) (Unit
|
||
= dB) <Help> This information
|
||
gives the target gain of the amplifier
|
||
for optimal performance
|
||
"
|
||
::= { pmoailhcMesrClient 35 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the clientCorrectedGain article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrclientCorrectedGain OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Gain :This OID gives the gain
|
||
value of the IL2 Module corrected
|
||
by the ASE compensation mechanism
|
||
(Gain =(AV-32768)*0,005) (Unit
|
||
= dB) <Help> This measure gives
|
||
the effective gain of the amplifier
|
||
"
|
||
::= { pmoailhcMesrClient 38 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaBiasMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrlineEdfaBiasMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Pump Laser Current :This OID
|
||
gives the pump laser current of
|
||
the IL1 Optical Module (Current
|
||
=AV/100) (Unit = mA) <Help> This
|
||
measure gives the bias of the IL1
|
||
pump laser
|
||
"
|
||
::= { pmoailhcMesrLine 40 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaTxpwrMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrlineEdfaTxpwrMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Tx Power :This OID gives the
|
||
transmit power value of the IL1
|
||
Optical Module (Power =(AV-32768)*0,005)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Tx optical power of the
|
||
IL1
|
||
"
|
||
::= { pmoailhcMesrLine 41 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaRxpwrMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrlineEdfaRxpwrMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL2 Rx Power :This OID gives the
|
||
receive power value of the IL2
|
||
Optical Module (Power =(AV-32768)*0,005)
|
||
(Unit = dBm) <Help> This measure
|
||
gives the Rx optical power of the
|
||
IL2
|
||
"
|
||
::= { pmoailhcMesrLine 42 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineEdfaGainMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrlineEdfaGainMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Gain Target :This OID gives
|
||
the gain value of the IL1 Module
|
||
(Gain =(AV-32768)*0,005) (Unit
|
||
= dB) <Help> This information
|
||
gives the target gain of the amplifier
|
||
for optimal performance
|
||
"
|
||
::= { pmoailhcMesrLine 43 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the lineCorrectedGain article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrlineCorrectedGain OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
IL1 Gain :This OID gives the gain
|
||
value of the IL1 Module corrected
|
||
by the ASE compensation mechanism
|
||
(Gain =(AV-32768)*0,005) (Unit
|
||
= dB) <Help> This measure gives
|
||
the effective gain of the amplifier
|
||
"
|
||
::= { pmoailhcMesrLine 46 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the tempMeas article
|
||
--- *****************************************************
|
||
|
||
pmoailhcMesrtempMeas OBJECT-TYPE
|
||
SYNTAX INTEGER (0..65535)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Module Temperature :This OID gives
|
||
the temperature of the PM (Temperature
|
||
=AV/256) (Unit = C) <Help> This
|
||
measure gives the temperature of
|
||
the module
|
||
"
|
||
::= { pmoailhcMesrOther 72 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- CONFIG
|
||
--- $$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$$
|
||
--- *****************************************************
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group noValue
|
||
--- *****************************************************
|
||
|
||
pmoailhcCfgNoValue OBJECT IDENTIFIER ::= { pmoailhcConfig 1 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2111
|
||
--- *****************************************************
|
||
|
||
pmoailhctableclientStartup OBJECT IDENTIFIER ::= { pmoailhcCfgNoValue 1 }
|
||
|
||
|
||
|
||
pmoailhcCfgclientEdfaLaserCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client Laser
|
||
:This OID configures the default
|
||
initialisation settings on the
|
||
client laser.
|
||
"
|
||
::= { pmoailhctableclientStartup 2 }
|
||
|
||
|
||
|
||
pmoailhcCfgclientEdfaLaserMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client mode
|
||
:This OID configures the default
|
||
mode on the client amplifier.
|
||
"
|
||
::= { pmoailhctableclientStartup 3 }
|
||
|
||
|
||
|
||
pmoailhcCfgclientGainValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client Gain
|
||
:This OID configures the default
|
||
gain on the client amplifier.
|
||
"
|
||
::= { pmoailhctableclientStartup 4 }
|
||
|
||
|
||
|
||
pmoailhcCfgclientTiltValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client Tilt
|
||
:This OID configures the default
|
||
tilt on the client amplifier.
|
||
"
|
||
::= { pmoailhctableclientStartup 5 }
|
||
|
||
|
||
|
||
pmoailhcCfgclientMsaLoss OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client MSA
|
||
:This OID configures the default
|
||
MSA value on the client amplifier.
|
||
"
|
||
::= { pmoailhctableclientStartup 6 }
|
||
|
||
|
||
|
||
pmoailhcCfgclientOutputPowerValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client Output
|
||
power :This OID configures the
|
||
default Output power value on
|
||
the client amplifier.
|
||
"
|
||
::= { pmoailhctableclientStartup 7 }
|
||
|
||
|
||
|
||
pmoailhcCfgclientAseCompensation OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Client ASE
|
||
:This OID configures the default
|
||
ASE compensation value on the client
|
||
amplifier.
|
||
"
|
||
::= { pmoailhctableclientStartup 8 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group lineStartUp
|
||
--- *****************************************************
|
||
|
||
pmoailhcCfgLineStartUp OBJECT IDENTIFIER ::= { pmoailhcConfig 2 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table 2191
|
||
--- *****************************************************
|
||
|
||
pmoailhctablelineStartup OBJECT IDENTIFIER ::= { pmoailhcCfgLineStartUp 1 }
|
||
|
||
|
||
|
||
pmoailhcCfglineEdfaLaserCtrl OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line Laser
|
||
:This OID configures the default
|
||
initialisation settings on the
|
||
line laser.
|
||
"
|
||
::= { pmoailhctablelineStartup 2 }
|
||
|
||
|
||
|
||
pmoailhcCfglineEdfaLaserMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line mode
|
||
:This OID configures the default
|
||
mode on the line amplifier.
|
||
"
|
||
::= { pmoailhctablelineStartup 3 }
|
||
|
||
|
||
|
||
pmoailhcCfglineGainValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line Gain
|
||
:This OID configures the default
|
||
gain on the line amplifier.
|
||
"
|
||
::= { pmoailhctablelineStartup 4 }
|
||
|
||
|
||
|
||
pmoailhcCfglineTiltValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line Tilt
|
||
:This OID configures the default
|
||
tilt on the line amplifier.
|
||
"
|
||
::= { pmoailhctablelineStartup 5 }
|
||
|
||
|
||
|
||
pmoailhcCfglineMsaLoss OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line MSA :This
|
||
OID configures the default MSA
|
||
value on the line amplifier.
|
||
"
|
||
::= { pmoailhctablelineStartup 6 }
|
||
|
||
|
||
|
||
pmoailhcCfglineOutputPowerValue OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line Output
|
||
power :This OID configures the
|
||
default Output power value on
|
||
the line amplifier.
|
||
"
|
||
::= { pmoailhctablelineStartup 7 }
|
||
|
||
|
||
|
||
pmoailhcCfglineAseCompensation OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default Settings on Line ASE :This
|
||
OID configures the default ASE
|
||
compensation value on the line
|
||
amplifier.
|
||
"
|
||
::= { pmoailhctablelineStartup 8 }
|
||
|
||
|
||
|
||
pmoailhcCfgaprMode OBJECT-TYPE
|
||
SYNTAX Unsigned32 (0..65536)
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default setting on module :This
|
||
OID configures the default mode
|
||
on the APR
|
||
"
|
||
::= { pmoailhctablelineStartup 11 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table Group labels
|
||
--- *****************************************************
|
||
|
||
pmoailhcCfgLabels OBJECT IDENTIFIER ::= { pmoailhcConfig 3 }
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmoailhcCfgLabelclientTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmoailhcCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmoailhcCfgLabels 1 }
|
||
|
||
|
||
pmoailhcCfgLabelclientEntry OBJECT-TYPE
|
||
SYNTAX PmoailhcCfgLabelclientEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmoailhcCfgLabelclientIndex }
|
||
::= { pmoailhcCfgLabelclientTable 1 }
|
||
|
||
|
||
PmoailhcCfgLabelclientEntry ::=
|
||
SEQUENCE {
|
||
pmoailhcCfgLabelclientIndex
|
||
INTEGER,
|
||
pmoailhcCfgLabelclientPortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmoailhcCfgLabelclientIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelclient
|
||
table
|
||
"
|
||
::= { pmoailhcCfgLabelclientEntry 1 }
|
||
|
||
|
||
pmoailhcCfgLabelclientPortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the Ports :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the ports.
|
||
"
|
||
::= { pmoailhcCfgLabelclientEntry 3 }
|
||
|
||
|
||
--- *****************************************************
|
||
--- LEAF for the table NO_VALUE
|
||
--- *****************************************************
|
||
|
||
pmoailhcCfgLabellineTable OBJECT-TYPE
|
||
SYNTAX SEQUENCE OF PmoailhcCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
List of Article
|
||
"
|
||
::= { pmoailhcCfgLabels 2 }
|
||
|
||
|
||
pmoailhcCfgLabellineEntry OBJECT-TYPE
|
||
SYNTAX PmoailhcCfgLabellineEntry
|
||
MAX-ACCESS not-accessible
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Row definition for the labels
|
||
table
|
||
"
|
||
INDEX { pmoailhcCfgLabellineIndex }
|
||
::= { pmoailhcCfgLabellineTable 1 }
|
||
|
||
|
||
PmoailhcCfgLabellineEntry ::=
|
||
SEQUENCE {
|
||
pmoailhcCfgLabellineIndex
|
||
INTEGER,
|
||
pmoailhcCfgLabellinePortn
|
||
DisplayString
|
||
}
|
||
|
||
|
||
pmoailhcCfgLabellineIndex OBJECT-TYPE
|
||
SYNTAX INTEGER(0..128)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Index definition for the labelline
|
||
table
|
||
"
|
||
::= { pmoailhcCfgLabellineEntry 1 }
|
||
|
||
|
||
pmoailhcCfgLabellinePortn OBJECT-TYPE
|
||
SYNTAX DisplayString( SIZE(1..16))
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"
|
||
Default settings on the label
|
||
of the lines :These registers
|
||
configures the default initialisation
|
||
settings of the labels of the lines.
|
||
"
|
||
::= { pmoailhcCfgLabellineEntry 3 }
|
||
|
||
|
||
|
||
pmoailhcCfgWriteConfiguration OBJECT-TYPE
|
||
SYNTAX EkiOnOff
|
||
MAX-ACCESS read-write
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Write configuration to module:This OID
|
||
writes the complete configuration to the module"
|
||
::= { pmoailhcConfig 257 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- TRAP OBJECTS
|
||
--- *****************************************************
|
||
|
||
pmoailhctrapBoardNumber OBJECT-TYPE
|
||
SYNTAX INTEGER(1..64)
|
||
MAX-ACCESS read-only
|
||
STATUS current
|
||
DESCRIPTION
|
||
"Last module which generates a trap"
|
||
::= { pmoailhctraps 4 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- GLOBAL TRAPS
|
||
--- *****************************************************
|
||
|
||
pmoailhcLineTrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmLineDdmWarning, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Line Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmoailhcAlmLineDdmWarning "on", pmoailhctrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Pre-Amp input or Booster Output of PMOAILHC in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default is activated"
|
||
::= { pmoailhctraps 30 }
|
||
|
||
pmoailhcLineTrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmLineDdmWarning, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Line Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOAILHC Line Not Urgent ON"}
|
||
--&MATCH { pmoailhcAlmLineDdmWarning "on", pmoailhctrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Pre-Amp input or Booster Output of PMOAILHC in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent Line default disappeared"
|
||
::= { pmoailhctraps 31 }
|
||
|
||
pmoailhcLineTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmLineDdmAlm, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Line Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmoailhcAlmLineDdmAlm "on", pmoailhctrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm appears on Pre-Amp input or Booster Output of PMOAILHC in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default is activated"
|
||
::= { pmoailhctraps 32 }
|
||
|
||
pmoailhcLineTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmLineDdmAlm, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Line Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOAILHC Line Urgent ON"}
|
||
--&MATCH { pmoailhcAlmLineDdmAlm "on", pmoailhctrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Pre-Amp input or Booster Output of PMOAILHC in slot $2 ($A)"
|
||
DESCRIPTION "Urgent Line default disappeared"
|
||
::= { pmoailhctraps 33 }
|
||
|
||
pmoailhcLineTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmLineFail, pmoailhcAlmLineHwFail, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Line Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmoailhcAlmLineFail "on", pmoailhcAlmLineHwFail "*", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOAILHC in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOAILHC Line HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmoailhcAlmLineFail "*", pmoailhcAlmLineHwFail "on", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on Pre-Amp input or Booster Output of PMOAILHC in slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default is activated"
|
||
::= { pmoailhctraps 34 }
|
||
|
||
pmoailhcLineTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmLineFail, pmoailhcAlmLineHwFail, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Line Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOAILHC Line Fail ON"}
|
||
--&MATCH { pmoailhcAlmLineFail "on", pmoailhcAlmLineHwFail "*", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOAILHC in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOAILHC Line HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmoailhcAlmLineFail "*", pmoailhcAlmLineHwFail "on", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on Pre-Amp input or Booster Output of PMOAILHC in slot $3 ($A)"
|
||
DESCRIPTION "Critical Line default disappeared"
|
||
::= { pmoailhctraps 35 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- PORTS TRAPS
|
||
--- *****************************************************
|
||
|
||
pmoailhcClientTrapNotUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmClientDdmWarning, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Client Not Urgent ON"
|
||
--&ACTIONS { log, minor }
|
||
--&MATCH { pmoailhcAlmClientDdmWarning "on", pmoailhctrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning appears on Booster input or Pre-Amp Output of PMOAILHC in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent client default is activated"
|
||
::= { pmoailhctraps 40 }
|
||
|
||
pmoailhcClientTrapNotUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmClientDdmWarning, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Client Not Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOAILHC Client Not Urgent ON"}
|
||
--&MATCH { pmoailhcAlmClientDdmWarning "on", pmoailhctrapBoardNumber "$2"}
|
||
--&MESG "DDM Warning disappears on Booster input or Pre-Amp Output of PMOAILHC in slot $2 ($A)"
|
||
DESCRIPTION "Not urgent client default disappeared"
|
||
::= { pmoailhctraps 41 }
|
||
|
||
pmoailhcClientTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmClientDdmAlm, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Client Urgent ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmoailhcAlmClientDdmAlm "on", pmoailhctrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm appears on Booster input or Pre-Amp Output of PMOAILHC in slot $2 ($A)"
|
||
DESCRIPTION "Urgent client default is activated"
|
||
::= { pmoailhctraps 42 }
|
||
|
||
pmoailhcClientTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmClientDdmAlm, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Client Urgent OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOAILHC Client Urgent ON"}
|
||
--&MATCH { pmoailhcAlmClientDdmAlm "on", pmoailhctrapBoardNumber "$2"}
|
||
--&MESG "DDM Alarm disappears on Booster input or Pre-Amp Output of PMOAILHC in slot $2 ($A)"
|
||
DESCRIPTION "Urgent client default disappeared"
|
||
::= { pmoailhctraps 43 }
|
||
|
||
pmoailhcClientTrapCritGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmClientFail, pmoailhcAlmClientHwFail, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Client Fail ON"
|
||
--&ACTIONS { log, critical }
|
||
--&MATCH { pmoailhcAlmClientFail "on", pmoailhcAlmClientHwFail "*", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOAILHC in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOAILHC Client HW Fail ON (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmoailhcAlmClientFail "*", pmoailhcAlmClientHwFail "on", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm appears on Booster input or Pre-Amp Output of PMOAILHC in slot $3 ($A)"
|
||
DESCRIPTION "Critical client default is activated"
|
||
::= { pmoailhctraps 44 }
|
||
|
||
pmoailhcClientTrapCritGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmClientFail, pmoailhcAlmClientHwFail, pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Client Fail OFF"
|
||
--&ACTIONS { log, normal }
|
||
--&CLEARS {"PMOAILHC Client Fail ON"}
|
||
--&MATCH { pmoailhcAlmClientFail "on", pmoailhcAlmClientHwFail "*", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOAILHC in slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOAILHC Client HW Fail OFF (Hidden)"
|
||
--&ACTIONS { info }
|
||
--&MATCH { pmoailhcAlmClientFail "*", pmoailhcAlmClientHwFail "on", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Critical Alarm disappears on Booster input or Pre-Amp Output of PMOAILHC in slot $3 ($A)"
|
||
DESCRIPTION "Critical client default disappeared"
|
||
::= { pmoailhctraps 45 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
--- *****************************************************
|
||
--- HW TRAPS
|
||
--- *****************************************************
|
||
|
||
pmoailhcPowerTrapUrgentGoesOn NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmDefFuseB, pmoailhcAlmDefFuseA , pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Fuse A Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmoailhcAlmDefFuseB "*", pmoailhcAlmDefFuseA "on", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Power Input A Fail on PMOAILHC in Slot $3 ($A)"
|
||
|
||
--&FILTNAME "PMOAILHC Fuse B Fail ON"
|
||
--&ACTIONS { log, major }
|
||
--&MATCH { pmoailhcAlmDefFuseB "on", pmoailhcAlmDefFuseA "*", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Power Input B Fail on PMOAILHC in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default is activated"
|
||
::= { pmoailhctraps 50 }
|
||
pmoailhcPowerTrapUrgentGoesOff NOTIFICATION-TYPE
|
||
OBJECTS {pmoailhcAlmDefFuseB, pmoailhcAlmDefFuseA , pmoailhctrapBoardNumber}
|
||
STATUS current
|
||
--&FILTNAME "PMOAILHC Fuse A&B Fail OFF"
|
||
--&ACTIONS { log, normal}
|
||
--&CLEARS { "PMOAILHC Fuse A Fail ON", "PMOAILHC Fuse B Fail ON" }
|
||
--&MATCH { pmoailhcAlmDefFuseB "on", pmoailhcAlmDefFuseA "on", pmoailhctrapBoardNumber "$3"}
|
||
--&MESG "Power Inputs A and B Present on PMOAILHC in Slot $3 ($A)"
|
||
DESCRIPTION "Urgent power supply default disappeared"
|
||
::= { pmoailhctraps 51 }
|
||
|
||
|
||
|
||
|
||
|
||
|
||
END
|