ARRIS-MTA-DEVICE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Integer32,
|
|
Counter32,
|
|
Counter64,
|
|
IpAddress
|
|
FROM SNMPv2-SMI
|
|
arrisProdIdCM
|
|
FROM ARRIS-MIB
|
|
TruthValue, DisplayString, TimeStamp, DateAndTime, TEXTUAL-CONVENTION, PhysAddress
|
|
FROM SNMPv2-TC
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
InetAddressType, InetAddress
|
|
FROM INET-ADDRESS-MIB;
|
|
|
|
arrisMtaDevMib MODULE-IDENTITY
|
|
LAST-UPDATED "1506250000Z" -- June 25, 2015
|
|
ORGANIZATION "ARRIS Broadband"
|
|
CONTACT-INFO "Rodney Osborne
|
|
Postal: ARRIS Broadband
|
|
3871 Lakefield Drive
|
|
Suite 300
|
|
Suwanee, GA 30024-1242
|
|
U.S.A.
|
|
Phone: +1 770-622-8400
|
|
E-mail: rodney.osborne@arrisi.com"
|
|
DESCRIPTION
|
|
"This MIB module supplies the basic proprietary
|
|
management objects for ARRIS MTA devices."
|
|
|
|
|
|
-- Revision history
|
|
REVISION "1506250000Z" -- June 25, 2015
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtadocsQosServiceTable, arrisMtadocsQosDisableLoggin, arrisMtadocsQosLogClear and arrisMtadocsQosShowDsxLogTable"
|
|
REVISION "1501200000Z" -- Jan 20, 2015
|
|
DESCRIPTION
|
|
"Change default value related description of mib arrisMtaDevPwrSupplyDataShutdownTime."
|
|
REVISION "1205020000Z" -- May 2, 2012
|
|
DESCRIPTION
|
|
"Add persistence to description for arrisMtaDevEndPntHDAudioEnable MIB and change default of arrisMtaDevWBSLIC to disable."
|
|
REVISION "1203160000Z" -- March 16, 2012
|
|
DESCRIPTION
|
|
"Added new table arrisMtaDevCmIpTable"
|
|
|
|
REVISION "1203150000Z" -- Mar 15, 2012
|
|
DESCRIPTION
|
|
"Modified OID for arrisMtaDevHDAudioEnable from 48 to 53"
|
|
REVISION "1203060000Z" -- Mar 6, 2012
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevHDAudioG722SampleRate"
|
|
REVISION "1202280000Z" -- Feb 28, 2012
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevProvisionedCodecArray"
|
|
REVISION "1202210000Z" -- Feb 21, 2012
|
|
DESCRIPTION
|
|
"Added MIBs to support HD Audio."
|
|
REVISION "1104180000Z" -- Apr 18, 2011
|
|
DESCRIPTION
|
|
"Modified MIB arrisMtaDevEndPntRingingWaveform description."
|
|
REVISION "1104070000Z" -- Apr 7, 2011
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevPwrSupplyEnableWifiShutdown"
|
|
|
|
REVISION "1006220000Z" -- June 22, 2010
|
|
DESCRIPTION
|
|
"Changed arrisMtaDevMaxCallPServiceFlows OID from { arrisMtaDevOperationalSetup 46 }
|
|
to { arrisMtaDevOperationalSetup 47 }"
|
|
|
|
REVISION "1005050000Z" -- May 5, 2010
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevMaxCallPServiceFlows"
|
|
|
|
REVISION "1003030000Z" -- March 3, 2010
|
|
DESCRIPTION
|
|
"Added new alarm autonomous types upsAlarmAwaitingPower and upsAlarmShutdownPending for
|
|
upsAlarmDescr MIB"
|
|
|
|
REVISION "1002100000Z" -- February 10, 2010
|
|
DESCRIPTION
|
|
"Added new alarm autonomous types upsAlarmBatteryBad, upsAlarmLowBattery, upsAlarmDepletedBattery,
|
|
upsAlarmUpsOutputOff, upsAlarmOutputOffAsRequested, upsAlarmGeneralFault, upsAlarmShutdownImminent,
|
|
upsAlarmBatteryMissing for upsAlarmDescr MIB"
|
|
|
|
REVISION "1001200000Z" -- January 20, 2010
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevEventFormat"
|
|
|
|
REVISION "0906300000Z" -- June 30, 2009
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevEndPntGainControlTxVoice, and arrisMtaDevEndPntGainControlRxVoice"
|
|
|
|
REVISION "0905040000Z" -- May 04, 2009
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevEndPntLoopReversal"
|
|
|
|
REVISION "0904290000Z" -- Apr 29, 2009
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevEndPntCIDEnable, arrisMtaDevEndPntCIDNameEnable,
|
|
arrisMtaDevEndPntCIDDateTimeEnable"
|
|
|
|
REVISION "0904200000Z" -- Apr 20, 2009
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevEndPntCallWaitingRepeatSteady"
|
|
|
|
REVISION "0812020000Z" -- Dec 02, 2008
|
|
DESCRIPTION
|
|
"Added new MIB arrisMtaDevPersistentLineStatus"
|
|
|
|
REVISION "0902020000Z" -- February 13, 2009
|
|
DESCRIPTION
|
|
"Added new mib arrisMtaDevDTMFEndEventForceAscending"
|
|
|
|
REVISION "0809220000Z" -- Sept 22, 2008
|
|
DESCRIPTION
|
|
"Added ac-Fail chargerOverTemp-Shutdown chargerTemperature-High
|
|
batteryCharger-Disabled chargerDownload-Failed and battery-Mismatch "
|
|
|
|
REVISION "0806170000Z" -- June 17, 2008
|
|
DESCRIPTION
|
|
"Added Null option to arrisMtaDevDefaultReasonNoCIDName and
|
|
added new MIB arrisMtaDevOffHookFskDelay"
|
|
|
|
REVISION "0806100000Z" -- Jun 10, 2008
|
|
DESCRIPTION
|
|
"Added arrisMtaDevEndPntFaxOnlyLineTimeout"
|
|
|
|
REVISION "0804120000Z" -- April 12, 2008
|
|
DESCRIPTION
|
|
"Added arrisMtaDevRestoreNvmFactoryDefault"
|
|
|
|
REVISION "0804220000Z" -- April 22, 2008
|
|
DESCRIPTION
|
|
"Added arrisMtaDevVqmCallNumberIdentifierLastCall"
|
|
|
|
REVISION "0804010000Z" -- April 01, 2008
|
|
DESCRIPTION
|
|
"Added arrisMtaDevPwrSupplyControlChargerReset"
|
|
|
|
REVISION "0802220000Z" -- February 22, 2008
|
|
DESCRIPTION
|
|
"Added arrisMtaDevPwrSupplyHighestTemperatureTime and
|
|
arrisMtaDevPwrSupplyHighestTemperatureClear"
|
|
|
|
REVISION "0802040000Z" -- February 04, 2008
|
|
DESCRIPTION
|
|
"Added arrisMtaDevPacketcableProvisioningFlow"
|
|
REVISION "0801290000Z" -- January 29, 2008
|
|
DESCRIPTION
|
|
"Added arrisMtaDevPwrSupplyHighestTemperature"
|
|
REVISION "0801170000Z" -- January 17, 2008
|
|
DESCRIPTION
|
|
"Increased range of arrisMtaDevGainControlRxVoice and TxVoice MIBs"
|
|
|
|
REVISION "0801170000Z" -- January 17, 2008
|
|
DESCRIPTION
|
|
"Added SDMF option to arrisMtaDevDefaultReasonNoCIDName"
|
|
|
|
REVISION "1107130000Z" -- November 13, 2007
|
|
DESCRIPTION
|
|
"Added arrisMtaDevGainControlOffHookEnable, arrisMtaDevGainControlOffHookFSK, and
|
|
arrisMtaDevGainControlOffHookCAS"
|
|
|
|
REVISION "1007300000Z" -- October 30,2007
|
|
DESCRIPTION
|
|
"Added arrisMtaDevAutomaticCallResourceRecovery"
|
|
|
|
REVISION "0707270000Z" -- July 27,2007
|
|
DESCRIPTION
|
|
"Added arrisMtaDevTDDReportToCMS"
|
|
|
|
REVISION "0704090000Z" -- April 9,2007
|
|
DESCRIPTION
|
|
"Added arrisMtaDevAutomaticOsiDelay."
|
|
|
|
REVISION "0611290000Z" -- March 29, 2006
|
|
DESCRIPTION
|
|
"Added arrisMtaDevTFTPServerAddrOverrideFQDN. Also added new ProvMethodIndicator
|
|
gupiTftpSvrOverride"
|
|
|
|
REVISION "0603290000Z" -- March 29, 2006
|
|
DESCRIPTION
|
|
"Added arrisMtaDevDspCpsSetting object."
|
|
|
|
REVISION "0602170000Z" -- February 17, 2006
|
|
DESCRIPTION
|
|
"Added in mib to allow for query of the Dhcp parameters per PD#76971."
|
|
|
|
REVISION "0502010000Z" -- February 1, 2005
|
|
DESCRIPTION
|
|
"Added object 'arrisMtaDevGainControl'."
|
|
REVISION "0507270000Z" -- July 27, 2005
|
|
DESCRIPTION
|
|
"Modified range for object 'arrisMtaDevGainControlLocalDTMF' from (-9..9) to (-15..9)."
|
|
|
|
REVISION "0502010000Z" -- February 1, 2005
|
|
DESCRIPTION
|
|
"Added object 'arrisMtaDevGainControl'."
|
|
|
|
REVISION "0501040000Z" -- January 4, 2005
|
|
DESCRIPTION
|
|
"Added object 'arrisMtaDevDspHandleNonPhaseReversedTone'."
|
|
|
|
REVISION "0412160000Z" -- December 16, 2004
|
|
DESCRIPTION
|
|
"Added object 'arrisMtaDevProvMethodIndicator' and table
|
|
'arrisMtaDevEndPntTable."
|
|
|
|
REVISION "0307110000Z" -- July 11, 2003
|
|
DESCRIPTION
|
|
"Initial version"
|
|
::= { arrisProdIdCM 3 }
|
|
|
|
|
|
-- Textual Conventions
|
|
ArrsMtaDevProvMethod ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION "These are the various provisioning methods that are
|
|
supported by the device."
|
|
SYNTAX INTEGER {
|
|
docsisOnly(0),
|
|
fullPacketCable(1),
|
|
packetCableMinusKDC(2),
|
|
cps(3),
|
|
gupi(4),
|
|
singleMAC(5),
|
|
basic1(6),
|
|
basic2(7),
|
|
gupiEncryptedMtaConfig(8),
|
|
gupiMacMta(9),
|
|
gupiEncryptedMacMta(10),
|
|
gupiTftpSvrOverride(11)
|
|
}
|
|
|
|
CodecType ::= TEXTUAL-CONVENTION
|
|
STATUS obsolete
|
|
DESCRIPTION "These are the various types of codecs that
|
|
may be supported."
|
|
SYNTAX INTEGER{
|
|
g711u(1),
|
|
g711a(2),
|
|
g7231(3),
|
|
g729(4),
|
|
g729a(5),
|
|
g729e(6),
|
|
g726(7),
|
|
g728(8)
|
|
}
|
|
|
|
PacketizationPeriodType ::= TEXTUAL-CONVENTION
|
|
STATUS obsolete
|
|
DESCRIPTION "The packetization periods supported by the PacketPort."
|
|
SYNTAX INTEGER{
|
|
ten(10),
|
|
twenty(20),
|
|
thirty(30)
|
|
}
|
|
|
|
SignalingProtocol ::= TEXTUAL-CONVENTION
|
|
STATUS obsolete
|
|
DESCRIPTION "These are the various signaling protocols
|
|
that may be supported."
|
|
SYNTAX INTEGER{
|
|
none(0),
|
|
ncs(1)}
|
|
|
|
|
|
-- This MIB module contains the following groups.
|
|
arrisMtaDevMibObjects OBJECT IDENTIFIER ::= { arrisMtaDevMib 1 }
|
|
|
|
arrisMtaDevBase OBJECT IDENTIFIER ::= { arrisMtaDevMibObjects 1 }
|
|
arrisMtaDevSetup OBJECT IDENTIFIER ::= { arrisMtaDevMibObjects 2 }
|
|
arrisMtaDevPowerSupplyTelemetry OBJECT IDENTIFIER ::= { arrisMtaDevMibObjects 3 }
|
|
arrisMtaDevLineCard OBJECT IDENTIFIER ::= { arrisMtaDevMibObjects 4 }
|
|
arrisMtaDispSignal OBJECT IDENTIFIER ::= { arrisMtaDevMibObjects 5 }
|
|
|
|
-- arrisMtaDevTest OBJECT IDENTIFIER ::= { arrisMtaDevMibObjects 5 }
|
|
|
|
arrisMtadocsQosService OBJECT IDENTIFIER ::= { arrisMtaDevMibObjects 6 }
|
|
|
|
|
|
arrisMtaDevMonitoringMib OBJECT IDENTIFIER ::= { arrisMtaDevBase 1 }
|
|
arrisMtaDevControl OBJECT IDENTIFIER ::= { arrisMtaDevMonitoringMib 1 }
|
|
arrisMtaDevTrace OBJECT IDENTIFIER ::= { arrisMtaDevMonitoringMib 2 }
|
|
arrisMtaDevParameters OBJECT IDENTIFIER ::= { arrisMtaDevMonitoringMib 3 }
|
|
arrisMtaDevVqm OBJECT IDENTIFIER ::= { arrisMtaDevMonitoringMib 4 }
|
|
|
|
arrisMtaDevDhcp OBJECT IDENTIFIER ::= { arrisMtaDevBase 2 }
|
|
|
|
-- Production groups
|
|
-- arrisMtaDevPermanentSetup OBJECT IDENTIFIER ::= { arrisMtaDevSetup 2 }
|
|
arrisMtaDevOperationalSetup OBJECT IDENTIFIER ::= { arrisMtaDevSetup 3 }
|
|
arrisMtaDevEndPntSetup OBJECT IDENTIFIER ::= { arrisMtaDevSetup 4 }
|
|
-- arrisMtaDevSalesSetup OBJECT IDENTIFIER ::= { arrisMtaDevSetup 4 }
|
|
|
|
arrisMtaDevOptionality OBJECT IDENTIFIER ::= { arrisMtaDevOperationalSetup 10 }
|
|
arrisMtaDevLoopVoltageMgmt OBJECT IDENTIFIER ::= { arrisMtaDevOperationalSetup 11 }
|
|
arrisMtaDevGainControl OBJECT IDENTIFIER ::= { arrisMtaDevOperationalSetup 12 }
|
|
arrisMtaDevLevelControl OBJECT IDENTIFIER ::= { arrisMtaDevOperationalSetup 40 }
|
|
arrisMtaDevDiag OBJECT IDENTIFIER ::= { arrisMtaDevOperationalSetup 15 }
|
|
arrisMtaDevCmIp OBJECT IDENTIFIER ::= { arrisMtaDevOperationalSetup 48 }
|
|
|
|
-- arrisMtaDevManufacturingTest OBJECT IDENTIFIER ::= { arrisMtaDevTest 2 }
|
|
-- arrisMtaDevOperationalTest OBJECT IDENTIFIER ::= { arrisMtaDevTest 3 }
|
|
|
|
|
|
|
|
--
|
|
-- The following group describes the Monitoring MIB control objects
|
|
-- in the Arris MTA device.
|
|
--
|
|
|
|
arrisMtaDevResetCallStats OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to true(1) will reset the following
|
|
objects to their default values:
|
|
arrisMtaDevRtpTxPktsTotal,
|
|
arrisMtaDevRtpRxPktsTotal,
|
|
arrisMtaDevRtpPercentPktsLostTotal,
|
|
arrisMtaDevSignalingAvgLatency,
|
|
arrisMtaDevSignalingTxSuccessfulMsgCnt,
|
|
arrisMtaDevSignalingRxSuccessfulMsgCnt,
|
|
arrisMtaDevSignalingTxNAKCnt,
|
|
arrisMtaDevSignalingRxNAKCnt,
|
|
arrisMtaDevSignalingRxNoACKCnt
|
|
Setting this object to false(2) will do nothing.
|
|
Reading this object always returns false(2)."
|
|
::= { arrisMtaDevControl 1 }
|
|
|
|
arrisMtaDevEnableCallpSigTrace OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object is used to turn Callp signaling Message tracing
|
|
on in the SYSLOG. This option should be used with care as excessive
|
|
messaging could adversly affect performance. The default value is disable(0)."
|
|
::= { arrisMtaDevControl 2 }
|
|
|
|
arrisMtaDevEnableCallStatsSyslogRpt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object is used to enable end of call statistics reporting and
|
|
Callp signaling last message reporting to syslog. If this is set to enable(1),
|
|
then the end of call statistics will be reported in syslog messaging.
|
|
If arrisMtaDevEnableCallSigLastMsgRpt is enabled, then the last 4K of signaling
|
|
message will be reported in syslog messageing as well. If the set to
|
|
diable(0), then end of call statistics and the Callp last signaling
|
|
messages will not be reported in syslog messaging. The default value is disable(0)."
|
|
::= { arrisMtaDevControl 3 }
|
|
|
|
arrisMtaDevSwDnldNoSvcImpact OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
strictEnable(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object is used to control the firmware download service impact feature.
|
|
The value is kept in non-volatile storage. Operation is as follows:
|
|
disable(0) - Always download firmware and reboot immediately after firmware download.
|
|
enable(1) - Download firmware immediately but delay the reboot until all lines
|
|
are on-hook and no connections are active.
|
|
StrictEnable(2) - Do not download firmware if any phone endpoint is off hook."
|
|
::= { arrisMtaDevControl 4 }
|
|
|
|
arrisMtaDevEnableCallSigLastMsgRpt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object is used to enable or disable reporting of the Callp signaling
|
|
'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16. Together the sixteen MIB objects can contain a
|
|
signaling message as large as 4000 bytes. Each of the sixteen MIB objects will
|
|
contain a 255 byte segment of the message. If the message is too small to require
|
|
all sixteen MIBs then the empty MIB objects will display the value 'Buffer is empty'.
|
|
The default value is disable(0)."
|
|
::= { arrisMtaDevControl 5 }
|
|
|
|
arrisMtaDevNsadSwDnldStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
download-Idle (0),
|
|
download-Acceptance-In-Progress (1),
|
|
download-Application-Pending (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object is set to download-Idle upon startup and when the firmware download has completed. The download-Acceptance-In-Progress setting denots that the unit is currently downloading the firmware in the background. The download-Application-Pending state is set to indicate the load has been downloaded and accepted but is waiting to be applied. This MIB object is only valid if the arrisMtaDevSwDnldNoSvcImpact MIB object is set to enabled (1)."
|
|
DEFVAL { download-Idle }
|
|
::= { arrisMtaDevControl 6 }
|
|
|
|
arrisMtaDevRestoreNvmFactoryDefault OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to true(1) will reset the NVM to default values:
|
|
Setting this object to false(2) will do nothing.
|
|
Reading this object always returns false(2)."
|
|
::= { arrisMtaDevControl 7 }
|
|
|
|
arrisMtaDevEnableLogging OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object is used to enable or disable logging via the
|
|
NCS logger. Use arrisMtaDevLoggingContext to specify the desired
|
|
log type."
|
|
::= { arrisMtaDevControl 8 }
|
|
|
|
arrisMtaDevLoggingContext OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mgcp(0),
|
|
cm-dhcp(1),
|
|
mta-dhcp(2),
|
|
dsx(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object sets the logging context for reading logs via SNMP."
|
|
|
|
::= { arrisMtaDevControl 9 }
|
|
|
|
arrisMtaDevEnablePacketLossConcealment OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object sets enable/disable of the Packet loss concealment(PLC) via SNMP."
|
|
|
|
::= { arrisMtaDevControl 10 }
|
|
|
|
arrisMtaDevEnableRTCPStaticInterval OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object sets enable/disable of RTCP static interval via SNMP."
|
|
DEFVAL { disable }
|
|
::= { arrisMtaDevControl 11 }
|
|
|
|
--
|
|
-- The following group describes the Monitoring MIB trace objects
|
|
-- in the Arris MTA device.
|
|
--
|
|
|
|
arrisMtaDevRtpTxPktsTotal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of RTP packets sent from the MTA
|
|
since it was last started up or reset. This value represents the total
|
|
number of packets sent for all endpoints combined. It is calculated from
|
|
values obtained from the signaling end of call statistics. Setting the MIB
|
|
object arrisMtaDevResetCallStats to a value of true(1) will clear this
|
|
counter."
|
|
::= { arrisMtaDevTrace 1 }
|
|
|
|
arrisMtaDevRtpRxPktsTotal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of RTP packets received from the MTA
|
|
since it was last started up or reset. This value represents the total
|
|
number of packets received for all endpoints combined. It is calculated from
|
|
values obtained from the signaling end of call statistics. Setting the MIB
|
|
object arrisMtaDevResetCallStats to a value of true(1) will clear this
|
|
counter."
|
|
::= { arrisMtaDevTrace 2 }
|
|
|
|
arrisMtaDevRtpPercentPktsLostTotal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the percentage of RTP packets lost since the MTA was
|
|
last started up or reset. This value represents the total number of packets
|
|
lost for all endpoints combined. It is calculated from values obtained from
|
|
the signaling end of call statistics. Setting the MIB object
|
|
arrisMtaDevResetCallStats to a value of true(1) will clear this counter. The
|
|
value field for this MIB object is represented as an integer value. However,
|
|
the actual value is a floating point type. For example a returned (integer)
|
|
value of '1745' will be displayed as '1745' but the actual (floating point) value
|
|
would be '17.45%' packets lost. Note: The MSO must divide the integer return
|
|
value by 100 to calculate the percentage value."
|
|
::= { arrisMtaDevTrace 3 }
|
|
|
|
arrisMtaDevProvState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dhcpBound(1),
|
|
dnsReqProvSvrIP(2),
|
|
kdcHostNameDnsReq(3),
|
|
kdcHostNameDnsRply(4),
|
|
kdcIpDnsReq(5),
|
|
kdcIpDnsRply(6),
|
|
asReqSent(7),
|
|
asRplyRcvd(8),
|
|
tgsReqSent(9),
|
|
tgsRplyRcvd(10),
|
|
apReqSent(11),
|
|
apRplyRcvd(12),
|
|
enrollmentInform(13),
|
|
cfgUrlSet(14),
|
|
dnsReqTftpSvrIp(15),
|
|
cfgFileReq(16),
|
|
rcvCfgFile(17),
|
|
syslogMsgProvComplete(18),
|
|
statusInform(19),
|
|
provcomplete(20)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MIB object arrisMtaDevProvState reports the current provisioning state of the MTA."
|
|
::= { arrisMtaDevTrace 4 }
|
|
|
|
arrisMtaDevSWUpgradeStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inProgress(1),
|
|
completeFromProvisioning(2),
|
|
completeFromMgt(3),
|
|
failed(4),
|
|
other(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the current software upgrade status of the device.
|
|
This MIB object obtains its value from the MIB object docsDevSwOperStatus."
|
|
::= { arrisMtaDevTrace 5 }
|
|
|
|
arrisMtaDevSignalingAvgLatency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the Average latency/delay for responses to signaling messages.
|
|
This is measured in milliseconds. It is calculated from values obtained from the
|
|
signaling end of call statistics. Setting the MIB object arrisMtaDevResetCallStats to
|
|
a value of true(1) will clear this MIB value."
|
|
::= { arrisMtaDevTrace 6 }
|
|
|
|
arrisMtaDevSignalingTxSuccessfulMsgCnt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of successful signaling messages sent from the
|
|
MTA. Setting the MIB object arrisMtaDevResetCallStats to a value of true(1) will clear
|
|
this counter."
|
|
::= { arrisMtaDevTrace 7 }
|
|
|
|
arrisMtaDevSignalingRxSuccessfulMsgCnt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of successful signaling messages received by the
|
|
MTA. Setting the MIB object arrisMtaDevResetCallStats to a value of true(1) will clear
|
|
this counter."
|
|
::= { arrisMtaDevTrace 8 }
|
|
|
|
arrisMtaDevSignalingTxNAKCnt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of negative acknowledgement signaling
|
|
messages (NAKmessages) sent from the MTA. Setting the MIB object
|
|
arrisMtaDevResetCallStats to a value of true(1) will clear this counter."
|
|
::= { arrisMtaDevTrace 9 }
|
|
|
|
arrisMtaDevSignalingRxNAKCnt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of negative acknowledgement signaling
|
|
messages (NAKmessages) received by the MTA. Setting the MIB object
|
|
arrisMtaDevResetCallStats to a value of true(1) will clear this counter."
|
|
::= { arrisMtaDevTrace 10 }
|
|
|
|
arrisMtaDevSignalingRxNoACKCnt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of 'no acknowledgement' signaling messages
|
|
received by the MTA. Setting the MIB object arrisMtaDevResetCallStats to a value of
|
|
true(1) will clear this counter."
|
|
::= { arrisMtaDevTrace 11 }
|
|
|
|
arrisMtaDevSignalingLastMsg1 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 12 }
|
|
|
|
arrisMtaDevSignalingLastMsg2 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 13 }
|
|
|
|
arrisMtaDevSignalingLastMsg3 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 14 }
|
|
|
|
arrisMtaDevSignalingLastMsg4 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 15 }
|
|
|
|
arrisMtaDevSignalingLastMsg5 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 16 }
|
|
|
|
arrisMtaDevSignalingLastMsg6 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 17 }
|
|
|
|
arrisMtaDevSignalingLastMsg7 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 18 }
|
|
|
|
arrisMtaDevSignalingLastMsg8 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 19 }
|
|
|
|
arrisMtaDevSignalingLastMsg9 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 20 }
|
|
|
|
arrisMtaDevSignalingLastMsg10 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 21 }
|
|
|
|
arrisMtaDevSignalingLastMsg11 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 22 }
|
|
|
|
arrisMtaDevSignalingLastMsg12 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 23 }
|
|
|
|
arrisMtaDevSignalingLastMsg13 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 24 }
|
|
|
|
arrisMtaDevSignalingLastMsg14 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 25 }
|
|
|
|
arrisMtaDevSignalingLastMsg15 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 26 }
|
|
|
|
arrisMtaDevSignalingLastMsg16 OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object displays a 255 byte segment of the Callp last signaling message sent or received.
|
|
This MIB object is one of sixteen total MIB objects which together can display a signaling message
|
|
as large as 4000 bytes. If the message is too small to require all sixteen MIBs then the empty MIB
|
|
objects will display the value 'Buffer is empty'. This MIB object must be enabled in order to display
|
|
messages. The MIB object arrisMtaDevEnableCallSigLastMsgRpt is used to enable or disable reporting
|
|
of the Callp signaling 'last message' to the MIB objects arrisMtaDevSignalingLastMsg1 through
|
|
arrisMtaDevSignalingLastMsg16."
|
|
::= { arrisMtaDevTrace 27 }
|
|
|
|
arrisMtaDevEstimatedMinutesRemaining OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the time to battery charge depletion
|
|
under the present load conditions if the utility power
|
|
is off and remains off, or if it were to be lost and
|
|
remain off. A value of -1 indicates the information
|
|
is unavailable at this time."
|
|
::= { arrisMtaDevTrace 44 }
|
|
|
|
arrisMtaDevEstimatedChargeRemaining OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
UNITS "percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the battery charge remaining expressed
|
|
as a percent of full charge. A value of -1 indicates
|
|
the information is unavailable at this time."
|
|
::= { arrisMtaDevTrace 45 }
|
|
|
|
--
|
|
-- The following group describes the Monitoring MIB Call Stats Table objects
|
|
-- in the Arris MTA device.
|
|
--
|
|
|
|
arrisMtaDevCallStatsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevCallStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table reports various end of call statistics."
|
|
::= { arrisMtaDevTrace 46 }
|
|
|
|
arrisMtaDevCallStatsEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevCallStatsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each end point entry represents one telephone line"
|
|
INDEX { arrisMtaDevCallStatsIndex }
|
|
::= { arrisMtaDevCallStatsTable 1 }
|
|
|
|
ArrisMtaDevCallStatsEntry ::= SEQUENCE {
|
|
arrisMtaDevCallStatsIndex Integer32,
|
|
arrisMtaDevCallStatsRtpTxPkts Integer32,
|
|
arrisMtaDevCallStatsRtpRxPkts Integer32,
|
|
arrisMtaDevCallStatsRtpPercentPktsLost Integer32,
|
|
arrisMtaDevCallStatsAvgJitter Integer32,
|
|
arrisMtaDevCallStatsMaxJitter Integer32,
|
|
arrisMtaDevCallStatsAvgLatency Integer32,
|
|
arrisMtaDevCallStatsHookStatus INTEGER,
|
|
arrisMtaDevCallStatsSLICStatus INTEGER,
|
|
arrisMtaDevCallStatsEndPntOpStatus INTEGER,
|
|
arrisMtaDevCallStatsLineSubState BITS
|
|
}
|
|
|
|
arrisMtaDevCallStatsIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The unique value which identifies the endpoint."
|
|
::= { arrisMtaDevCallStatsEntry 1 }
|
|
|
|
arrisMtaDevCallStatsRtpTxPkts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of RTP packets sent from
|
|
the MTA during the most recent call. This MIB object is included
|
|
in a table of MIB objects which indexed by the endpoint (line number).
|
|
Its value represents the total number of packets sent per endpoint.
|
|
This value is obtained from the signaling end of call statistics."
|
|
::= { arrisMtaDevCallStatsEntry 2 }
|
|
|
|
arrisMtaDevCallStatsRtpRxPkts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the total number of RTP packets received by
|
|
the MTA during the most recent call. This MIB object is included
|
|
in a table of MIB objects which indexed by the endpoint (line number).
|
|
Its value represents the total number of packets received per endpoint.
|
|
This value is obtained from the signaling end of call statistics."
|
|
::= { arrisMtaDevCallStatsEntry 3 }
|
|
|
|
arrisMtaDevCallStatsRtpPercentPktsLost OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the percentage of RTP packets lost during the most
|
|
recent call. This MIB object is included in a table of MIB objects which
|
|
indexed by the endpoint (line number). Its value represents the total number
|
|
of packets lost per endpoint. It is calculated from values obtained from the
|
|
signaling end of call statistics. The value field for this MIB object is
|
|
represented as an integer value. However, the actual value is a floating point
|
|
type. For example A returned (integer) value of '1745' will be displayed as
|
|
'1745' but the actual (floating point) value would be '17.45%' packets lost.
|
|
Note: The MSO must divide the integer return value by 100 to calculate the
|
|
percentage value."
|
|
::= { arrisMtaDevCallStatsEntry 4 }
|
|
|
|
arrisMtaDevCallStatsAvgJitter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the average jitter measurement during the most recent call.
|
|
This MIB object is included in a table of MIB objects which indexed by the endpoint
|
|
(line number). Its value represents the average jitter measurement per endpoint.
|
|
This value is measured in units of milliseconds. This value is obtained from the
|
|
signaling end of call statistics."
|
|
::= { arrisMtaDevCallStatsEntry 5 }
|
|
|
|
arrisMtaDevCallStatsMaxJitter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the maximum jitter measurement during the most recent call.
|
|
This MIB object is included in a table of MIB objects which indexed by the endpoint
|
|
(line number). Its value represents the maximum jitter measurement per endpoint.
|
|
This value is measured in units of milliseconds. This value is obtained from DSP
|
|
statistics."
|
|
::= { arrisMtaDevCallStatsEntry 6 }
|
|
|
|
arrisMtaDevCallStatsAvgLatency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the average latency observed during the most recent call.
|
|
This MIB object is included in a table of MIB objects which indexed by the endpoint
|
|
(line number). This value is measured in units of milliseconds. This value is
|
|
obtained from the signaling end of call statistics."
|
|
::= { arrisMtaDevCallStatsEntry 7 }
|
|
|
|
arrisMtaDevCallStatsHookStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
onHook(0),
|
|
offHook(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the hook status for each endpoint.
|
|
Note: The disconnected state is not a valid return value for this MIB object."
|
|
::= { arrisMtaDevCallStatsEntry 9 }
|
|
|
|
arrisMtaDevCallStatsSLICStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
overtemp(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the over temperature condition of the SLIC chips."
|
|
::= { arrisMtaDevCallStatsEntry 10 }
|
|
|
|
arrisMtaDevCallStatsEndPntOpStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1), -- ready to pass packets
|
|
down(2),
|
|
testing(3) -- in some test mode
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the current operational status for each endpoint.
|
|
This MIB object obtains its value from the MIB object ifAdminOperStatus."
|
|
::= { arrisMtaDevCallStatsEntry 11 }
|
|
|
|
arrisMtaDevCallStatsLineSubState OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
normal(0),
|
|
diagsPending(1),
|
|
diagsFailed(2),
|
|
lcProtection(3),
|
|
dspFail(4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the current sub state for each line.
|
|
This MIB object obtains its value from the lineRec."
|
|
::= { arrisMtaDevCallStatsEntry 12 }
|
|
|
|
arrisMtaDevRtpPktsLostTotal OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the RTP packets lost since the MTA was
|
|
last started up or reset. This value represents the total number of packets
|
|
lost for all endpoints combined. It is calculated from values obtained from
|
|
the signaling end of call statistics. Setting the MIB object
|
|
arrisMtaDevResetCallStats to a value of true(1) will clear this counter."
|
|
::= { arrisMtaDevTrace 47 }
|
|
|
|
arrisMtaDevLastCallStartTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the last call start time from the eMTA. "
|
|
::= { arrisMtaDevTrace 48 }
|
|
|
|
arrisMtaDevLastCallEndTime OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reports the last call end time from the eMTA. "
|
|
::= { arrisMtaDevTrace 49 }
|
|
|
|
--
|
|
-- The following group describes Voice Quality Monitoring objects
|
|
-- in the Arris MTA device.
|
|
--
|
|
|
|
arrisMtaDevVqmLine OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the line for Voice Quality Metrics reporting."
|
|
DEFVAL { 1 }
|
|
::= { arrisMtaDevVqm 1 }
|
|
|
|
|
|
arrisMtaDevVqmClear OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
single-line(0),
|
|
all-lines(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clears Voice Quality Metrics for a single line or for all lines.
|
|
Line number is specified using arrisMtaDevVqmLine."
|
|
DEFVAL { single-line }
|
|
::= { arrisMtaDevVqm 2 }
|
|
|
|
|
|
arrisMtaDevVqmEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables/Disables recording Local Voice Metrics."
|
|
DEFVAL { enable }
|
|
::= { arrisMtaDevVqm 3 }
|
|
|
|
|
|
arrisMtaDevVqmCallNumberTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevVqmCallNumberEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice Quality Metric history on a per call number basis. This table
|
|
provides call number history identifiers that can be entered into
|
|
arrisMtaDevVqmIdent to provide statistics for a particular call number."
|
|
::= { arrisMtaDevVqm 4 }
|
|
|
|
|
|
arrisMtaDevVqmCallNumberEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevVqmCallNumberEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice Quality Metric history on a per call number basis."
|
|
INDEX { arrisMtaDevVqmCallNumberIndex }
|
|
::= { arrisMtaDevVqmCallNumberTable 1 }
|
|
|
|
|
|
ArrisMtaDevVqmCallNumberEntry ::= SEQUENCE {
|
|
arrisMtaDevVqmCallNumberIndex Integer32,
|
|
arrisMtaDevVqmCallNumberIds DisplayString }
|
|
|
|
|
|
arrisMtaDevVqmCallNumberIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A unique value which identifies the call number."
|
|
::= { arrisMtaDevVqmCallNumberEntry 1 }
|
|
|
|
|
|
arrisMtaDevVqmCallNumberIds OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays a history of Call number identifiers for the specified line."
|
|
::= { arrisMtaDevVqmCallNumberEntry 2 }
|
|
|
|
|
|
|
|
|
|
arrisMtaDevVqmCallNumberIdentifier OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the call number for Voice Quality Metrics reporting. Valid Ids
|
|
to be entered here are obtained from arrisMtaDevVqmCallNumberIds."
|
|
DEFVAL { 1 }
|
|
::= { arrisMtaDevVqm 5 }
|
|
|
|
|
|
arrisMtaDevVqmMetricTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevVqmMetricEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice Quality Metrics pertaining to a particular call number."
|
|
::= { arrisMtaDevVqm 6 }
|
|
|
|
|
|
arrisMtaDevVqmEnableRemote OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal(0),
|
|
forceDisable(1),
|
|
forceEnable(2),
|
|
default(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines policy to control Remote Voice Metrics (XR). The value of
|
|
this MIB is persistent if it is set after configuration.
|
|
When set to 'default', the value is restored to the default value, and it
|
|
is no longer persistent.
|
|
forceDisable - disables XR. Overrides directive from Call Server.
|
|
forceEnable - enables XR. Overrides directive from Call Server.
|
|
normal - has no effect. Call Server Directives are obeyed.
|
|
default - use the default value. The MIB is reset to the default value,
|
|
and the corresponding value in NVM is cleared."
|
|
DEFVAL { normal }
|
|
::= { arrisMtaDevVqm 7 }
|
|
|
|
|
|
arrisMtaDevVqmThresholdEnable OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Zero Disables threshold reporting for Voice Metrics. Non-zero specifies the
|
|
maximum number of logs allowed to be sent to report when a threshold is
|
|
exceeded. The more logs that are allowed, the more metrics that can be
|
|
reported. Metrics are reported in the order specified in
|
|
arrisMtaDevVqmMetricIndex. To minimize network traffic, logs are sent only
|
|
when a threshold is first exceeded. Thereafter until the metric returns to
|
|
normal, logs are inhibited. To change this operation to send logs each
|
|
time the threshold is exceeded, add 100 to the MIB value. "
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevVqm 8 }
|
|
|
|
arrisMtaDevVqmHistorySize OBJECT-TYPE
|
|
SYNTAX Integer32 (2..50)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The history size of Vqm record. Range 2 to 50."
|
|
DEFVAL { 10 }
|
|
::= { arrisMtaDevVqm 9 }
|
|
|
|
arrisMtaDevVqmCallNumberIdentifierLastCall OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last call identifier for Voice Quality Metrics reporting."
|
|
::= { arrisMtaDevVqm 10 }
|
|
|
|
arrisMtaDevVqmMetricEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevVqmMetricEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice Quality Metrics pertaining to a particular call number."
|
|
INDEX { arrisMtaDevVqmMetricIndex }
|
|
::= { arrisMtaDevVqmMetricTable 1 }
|
|
|
|
|
|
ArrisMtaDevVqmMetricEntry ::= SEQUENCE {
|
|
arrisMtaDevVqmMetricIndex INTEGER,
|
|
arrisMtaDevVqmMetricValues DisplayString,
|
|
arrisMtaDevVqmThresholds DisplayString }
|
|
|
|
|
|
-- When metrics are added/deleted make sure the values VQMETRIC_COMMON_MAX,
|
|
-- VQMETRIC_LOCAL_MAX & VQMETRIC_REMOTE_MAX are updated in callp_vqmon.h
|
|
--
|
|
arrisMtaDevVqmMetricIndex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
-- Common Metrics
|
|
callEndTime(1),
|
|
callStartTime(2),
|
|
callDuration(3),
|
|
lineNumber(4),
|
|
remIpAddress(5),
|
|
cwErrors(6),
|
|
cwErrorRate(7),
|
|
dsSNR(8),
|
|
microReflections(9),
|
|
dsPwr(10),
|
|
usPwr(11),
|
|
eqiAverage(12),
|
|
eqiMin(13),
|
|
eqiMax(14),
|
|
eqiInstantaneous(15),
|
|
-- Local Metrics
|
|
mOS-LQ(16),
|
|
mOS-CQ(17),
|
|
rERL(18),
|
|
signalLevel(19),
|
|
noiseLevel(20),
|
|
lossRate(21),
|
|
plConcealment(22),
|
|
discardRate(23),
|
|
burstDensity(24),
|
|
gapDensity(25),
|
|
burstDuration(26),
|
|
gapDuration(27),
|
|
rTDelay(28),
|
|
endSystemDelay(29),
|
|
minGapSize(30),
|
|
rFactor(31),
|
|
extRFactor(32),
|
|
jbAdaptive(33),
|
|
jbRate(34),
|
|
jBNomDelay(35),
|
|
jBMaxDelay(36),
|
|
jBAbsMaxDelay(37),
|
|
-- Remote Metrics
|
|
mOS-LQRem(38),
|
|
mOS-CQRem(39),
|
|
rERLRem(40),
|
|
signalLevelRem(41),
|
|
noiseLevelRem(42),
|
|
lossRateRem(43),
|
|
plConcealmentRem(44),
|
|
discardRateRem(45),
|
|
burstDensityRem(46),
|
|
gapDensityRem(47),
|
|
burstDurationRem(48),
|
|
gapDurationRem(49),
|
|
rTDelayRem(50),
|
|
endSystemDelayRem(51),
|
|
minGapSizeRem(52),
|
|
rFactorRem(53),
|
|
extRFactorRem(54),
|
|
jbAdaptiveRem(55),
|
|
jbRateRem(56),
|
|
jBNomDelayRem(57),
|
|
jBMaxDelayRem(58),
|
|
jBAbsMaxDelayRem(59),
|
|
-- New Local Metrcs
|
|
txPackets(60),
|
|
txOctets(61),
|
|
rxPackets(62),
|
|
rxOctets(63),
|
|
packetLoss(64),
|
|
intervalJitter(65),
|
|
originator(66),
|
|
intervalJitterRem(67),
|
|
txcodec(68),
|
|
rxcodec(69)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A unique value which identifies the metric."
|
|
::= { arrisMtaDevVqmMetricEntry 1 }
|
|
|
|
|
|
arrisMtaDevVqmMetricValues OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays metrics for the specified call number."
|
|
::= { arrisMtaDevVqmMetricEntry 2 }
|
|
|
|
|
|
arrisMtaDevVqmThresholds OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets/displays metric thresholds."
|
|
::= { arrisMtaDevVqmMetricEntry 3 }
|
|
|
|
|
|
|
|
|
|
-- The follow MIB OID is used on Dev0 and should be reserved
|
|
-- ::= { arrisMtaDevCallStatsEntry 12 }
|
|
|
|
-- The following group describes the Monitoring MIB parameter objects
|
|
-- on the Arris MTA device.
|
|
--
|
|
|
|
arrisMtaDevMaxCpeAllowed OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reflects the 'MaxCpeAllowed' parameter in the CM config file."
|
|
::= { arrisMtaDevParameters 1 }
|
|
|
|
arrisMtaDevNetworkAccess OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
no(0),
|
|
yes(1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reflects the value of the 'NetworkAccess' parameter set in the CM config file."
|
|
::= { arrisMtaDevParameters 2 }
|
|
|
|
--
|
|
-- The following group describes the Monitoring MIB Line Parameter Table objects
|
|
-- on the Arris MTA device.
|
|
--
|
|
|
|
arrisMtaDevLineParameterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevLineParameterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table reports various line parameters on the eMTA."
|
|
::= { arrisMtaDevParameters 3 }
|
|
|
|
arrisMtaDevLineParameterEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevLineParameterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each end point entry represents one telephone line"
|
|
INDEX { arrisMtaDevInterfaceIndex }
|
|
::= { arrisMtaDevLineParameterTable 1 }
|
|
|
|
ArrisMtaDevLineParameterEntry ::= SEQUENCE {
|
|
arrisMtaDevInterfaceIndex Integer32,
|
|
arrisMtaDevPktcDevEvEndpointName SnmpAdminString,
|
|
arrisMtaDevActiveConnections Integer32,
|
|
arrisMtaDevLineMWIActive TruthValue
|
|
}
|
|
|
|
arrisMtaDevInterfaceIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object shows the corresponding ifTable ifindex object for a particular line."
|
|
::= { arrisMtaDevLineParameterEntry 1 }
|
|
|
|
arrisMtaDevPktcDevEvEndpointName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object provides the endpoint name in the following format: 'AALN/X:FQDN/IP Address'."
|
|
::= { arrisMtaDevLineParameterEntry 2 }
|
|
|
|
arrisMtaDevActiveConnections OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object shows the number of connections for a particular line whose mode is receive only, send only, send/receive, but not inactive."
|
|
::= { arrisMtaDevLineParameterEntry 3 }
|
|
|
|
arrisMtaDevLineMWIActive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object shows the MWI is active or not."
|
|
::= { arrisMtaDevLineParameterEntry 4 }
|
|
|
|
--
|
|
-- The following group describes the Monitoring MIB Upstream Service Flow Parameter Table objects
|
|
-- in the Arris MTA device.
|
|
--
|
|
|
|
arrisMtaDevUpSvcFlowParameterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevUpSvcFlowParameterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table reports various Upstream Service Flow parameters on the eMTA."
|
|
::= { arrisMtaDevParameters 4 }
|
|
|
|
arrisMtaDevUpSvcFlowParameterEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevUpSvcFlowParameterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each end point entry represents one upstream service flow index"
|
|
INDEX { arrisMtaDevDocsQosParamUpSvcFlowSFID }
|
|
::= { arrisMtaDevUpSvcFlowParameterTable 1 }
|
|
|
|
ArrisMtaDevUpSvcFlowParameterEntry ::= SEQUENCE {
|
|
arrisMtaDevDocsQosParamUpSvcFlowSFID Integer32,
|
|
arrisMtaDevDocsQosParamUpSvcFlowSchedulingType Integer32
|
|
}
|
|
|
|
arrisMtaDevDocsQosParamUpSvcFlowSFID OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object shows the corresponding upstream service flow SFID for a valid service flow index."
|
|
::= { arrisMtaDevUpSvcFlowParameterEntry 1 }
|
|
|
|
arrisMtaDevDocsQosParamUpSvcFlowSchedulingType OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object shows the corresponding upstream service flow scheduling type for a valid service flow index."
|
|
::= { arrisMtaDevUpSvcFlowParameterEntry 2 }
|
|
|
|
|
|
arrisMtaDevQosMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dsxMode (1),
|
|
bestEffort-FullDQos-PCMM (0)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object reflects the CPFS_DSX_DQOS bit of the Callp Feature Switch setting."
|
|
::= { arrisMtaDevParameters 5 }
|
|
|
|
arrisMtaDevEventFormat OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
pktc10 (0),
|
|
pktc15 (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to determine which packet cable event format we are using:
|
|
pktc10(0): pktc 1.0 event,
|
|
pktc15(1): pktc 1.5 event."
|
|
::= { arrisMtaDevParameters 6 }
|
|
|
|
--
|
|
-- The following group describes the Dhcp parameters objects
|
|
-- in the Arris MTA device.
|
|
--
|
|
|
|
arrisMtaDevDhcpMtaParameters OBJECT IDENTIFIER ::= { arrisMtaDevDhcp 1 }
|
|
arrisMtaDevDhcpSvrParameters OBJECT IDENTIFIER ::= { arrisMtaDevDhcp 2 }
|
|
arrisMtaDevDhcpLeaseParameters OBJECT IDENTIFIER ::= { arrisMtaDevDhcp 3 }
|
|
arrisMtaDevDhcpPktcOptParameters OBJECT IDENTIFIER ::= { arrisMtaDevDhcp 4 }
|
|
|
|
|
|
arrisMtaDevDhcpMtaIpFQDN OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the currently defined MTA FQDN."
|
|
::= { arrisMtaDevDhcpMtaParameters 1 }
|
|
|
|
arrisMtaDevDhcpMtaIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the currently leased IP address ."
|
|
::= { arrisMtaDevDhcpMtaParameters 2 }
|
|
|
|
arrisMtaDevDhcpMtaSubNetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the current IP subnet mask in use."
|
|
::= { arrisMtaDevDhcpMtaParameters 3 }
|
|
|
|
arrisMtaDevDhcpMtaGatewayIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the current IP gateway address in use."
|
|
::= { arrisMtaDevDhcpMtaParameters 4 }
|
|
|
|
arrisMtaDevDhcpMtaConfigFile OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the MTA configuration file to be retrived."
|
|
::= { arrisMtaDevDhcpMtaParameters 5 }
|
|
|
|
arrisMtaDevDhcpState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle (0), -- MTA is waiting to start the DHCP process.
|
|
discover (1), -- MTA is currently trying to discover its IP address.
|
|
selecting (2), -- MTA is currently trying to select its IP address.
|
|
requesting(3), -- MTA is currently trying to request its IP address.
|
|
bound (4), -- IP Address is leased and no rebind/renew operation is taking place.
|
|
renew (5), -- MTA is currently trying to renew its IP address.
|
|
rebind (6) -- MTA is currently trying to rebind its IP address.
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the current Dhcp state of the MTA."
|
|
::= { arrisMtaDevDhcpSvrParameters 1 }
|
|
|
|
arrisMtaDevDhcpPrimaryDhcpSvrIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the primary Dhcp server address."
|
|
::= { arrisMtaDevDhcpSvrParameters 2 }
|
|
|
|
arrisMtaDevDhcpSecondaryDhcpSvrIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the secondary Dhcp server address."
|
|
::= { arrisMtaDevDhcpSvrParameters 3 }
|
|
|
|
|
|
arrisMtaDevDhcpPrimaryDNSSvrIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the primary DNS server address."
|
|
::= { arrisMtaDevDhcpSvrParameters 4 }
|
|
|
|
arrisMtaDevDhcpSecondaryDNSSvrIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the secondary DNS server address."
|
|
::= { arrisMtaDevDhcpSvrParameters 5 }
|
|
|
|
|
|
arrisMtaDevDhcpOfferedLeaseTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the current IP Lease time expressed in seconds."
|
|
::= { arrisMtaDevDhcpLeaseParameters 1 }
|
|
|
|
arrisMtaDevDhcpLeaseTimeRemaining OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the remaining IP Lease time expressed in seconds."
|
|
::= { arrisMtaDevDhcpLeaseParameters 2 }
|
|
|
|
arrisMtaDevDhcpTimeUntilRenew OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the current time remaining before the MTA starts the lease renewal
|
|
process. This time is expressed in seconds."
|
|
::= { arrisMtaDevDhcpLeaseParameters 3 }
|
|
|
|
arrisMtaDevDhcpTimeUntilRebind OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the current time remaining before the MTA starts the lease rebinding
|
|
process. This time is expressed in seconds."
|
|
::= { arrisMtaDevDhcpLeaseParameters 4 }
|
|
|
|
arrisMtaDevDhcpPktcOptionId OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This displays the Pktc DHCP Option ID of 122/177."
|
|
::= { arrisMtaDevDhcpPktcOptParameters 1 }
|
|
|
|
arrisMtaDevDhcpSvcProviderSnmpEntity OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current FQDN of the Service Provider's SNMP Entity."
|
|
::= { arrisMtaDevDhcpPktcOptParameters 2 }
|
|
|
|
arrisMtaDevDhcpKerberosRealmFqdn OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FQDN of the Kerberos Realm. The PacketCable architecture requires an
|
|
MTA to authenticate itself to the TSP's network via the Kerberos protocol.
|
|
A Kerberos Realm name is required at the MTA to permit a DNS lookup for the
|
|
address of the TSP's Kerberos Key Distribution Center (KDC) entity."
|
|
::= { arrisMtaDevDhcpPktcOptParameters 3 }
|
|
|
|
arrisMtaDevDhcpRequestTgt OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This sub-option encodes a boolean value which indicates whether an
|
|
MTA should or should not utilize a TGT (Ticket Granting Ticket) when
|
|
obtaining a service ticket for one of the PacketCable application
|
|
servers.
|
|
TRUE : Utilize the TGT process.
|
|
FALSE: Do not utilize the TGT process."
|
|
::= { arrisMtaDevDhcpPktcOptParameters 4 }
|
|
|
|
arrisMtaDevDhcpProvTimer OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The provisioning timer defines the maximum time allowed for the MTA
|
|
provisioning process to complete. If this timer expires before the
|
|
MTA has completed the provisioning process, the MTA should reset the
|
|
timer and re-start its provisioning process from the beginning."
|
|
::= { arrisMtaDevDhcpPktcOptParameters 5 }
|
|
|
|
arrisMtaDevDhcpSecTicketInvalid OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
invalidateProvOnReboot (0),
|
|
invalidateAllCmsOnReboot (1)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object defines a Kerberos Ticket Control Mask that
|
|
instructs the MTA to invalidate the specific application
|
|
server Kerberos ticket(s) that are stored locally in the
|
|
MTA NVRAM (non-volatile or persistent memory).
|
|
If the MTA does not stored Kerberos tickets in NVRAM, it
|
|
MUST ignore setting of this object, and MUST report a BITS
|
|
value of zero when the object is read.
|
|
If the MTA supports Kerberos tickets storage in NVRAM, the
|
|
object value is encoded as follows:
|
|
- setting the invalidateProvOnReboot bit (bit 0) to 1
|
|
means that the MTA MUST invalidate the Kerberos
|
|
Application Ticket(s) for the Provisioning Application
|
|
at the next MTA reboot,
|
|
- setting the invalidateAllCmsOnReboot bit (bit 1) to 1
|
|
means that the MTA MUST invalidate the Kerberos
|
|
Application Ticket(s) for all CMSes currently assigned
|
|
to the MTA endpoints."
|
|
::= { arrisMtaDevDhcpPktcOptParameters 6 }
|
|
|
|
--
|
|
-- The following group describes the Power Supply Telemetry objects
|
|
-- in the Arris MTA device.
|
|
--
|
|
arrisMtaDevPwrSupplyBase OBJECT IDENTIFIER ::= { arrisMtaDevPowerSupplyTelemetry 2 }
|
|
arrisMtaDevPwrSupplyControl OBJECT IDENTIFIER ::= { arrisMtaDevPowerSupplyTelemetry 3 }
|
|
arrisMtaDevPwrSupplyTimers OBJECT IDENTIFIER ::= { arrisMtaDevPowerSupplyTelemetry 4 }
|
|
arrisMtaDevPwrSupplyStats OBJECT IDENTIFIER ::= { arrisMtaDevPowerSupplyTelemetry 5 }
|
|
arrisMtaDevPwrSupplyAlarm OBJECT IDENTIFIER ::= { arrisMtaDevPowerSupplyTelemetry 6 }
|
|
|
|
--
|
|
-- The following describes the line card tabl and entry that displays the state of the
|
|
-- line cards. Objects are in the Arris MTA device.
|
|
--
|
|
arrisMtaDevLineCardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevLineCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the state of each line card."
|
|
::= { arrisMtaDevLineCard 1 }
|
|
|
|
arrisMtaDevLineCardEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevLineCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the line card table."
|
|
INDEX { arrisMtaDevLineCardLineNumber }
|
|
::= { arrisMtaDevLineCardTable 1 }
|
|
|
|
ArrisMtaDevLineCardEntry ::= SEQUENCE{
|
|
arrisMtaDevLineCardLineNumber Integer32, -- INDEX item
|
|
arrisMtaDevLineCardState INTEGER
|
|
}
|
|
|
|
arrisMtaDevLineCardLineNumber OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The unique value which identifies the line card."
|
|
::= { arrisMtaDevLineCardEntry 1 }
|
|
|
|
arrisMtaDevLineCardState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
idle (1),
|
|
addressing (2),
|
|
talking (3),
|
|
frwd-disc (5),
|
|
ringing (6),
|
|
onhook-tx (7),
|
|
plo (14)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The line card state of the line."
|
|
::= { arrisMtaDevLineCardEntry 2 }
|
|
|
|
-- Ali PD 78887 END
|
|
|
|
-- PD 189252
|
|
arrisMtaDispSignalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDispSignalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the NCS/SIP log"
|
|
::= { arrisMtaDispSignal 1 }
|
|
|
|
arrisMtaDispSignalEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDispSignalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the log table."
|
|
INDEX { arrisMtaDevDispSignalLogindex }
|
|
::= { arrisMtaDispSignalTable 1 }
|
|
|
|
ArrisMtaDispSignalEntry ::= SEQUENCE{
|
|
arrisMtaDevDispSignalLogindex INTEGER,
|
|
arrisMtaDevDispSignalLog OCTET STRING
|
|
}
|
|
|
|
arrisMtaDevDispSignalLogindex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The index of signal log."
|
|
::= { arrisMtaDispSignalEntry 1 }
|
|
|
|
arrisMtaDevDispSignalLog OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..2048))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Show the log of signal"
|
|
::= { arrisMtaDispSignalEntry 2 }
|
|
|
|
arrisMtadocsQosServiceTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtadocsQosServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the NCS/SIP log"
|
|
::= { arrisMtadocsQosService 1 }
|
|
|
|
arrisMtadocsQosServiceEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtadocsQosServiceEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the Mta Qos log table."
|
|
INDEX { arrisMtadocsQosServiceIndex }
|
|
::= { arrisMtadocsQosServiceTable 1 }
|
|
|
|
ArrisMtadocsQosServiceEntry ::= SEQUENCE{
|
|
arrisMtadocsQosServiceIndex INTEGER,
|
|
arrisMtadocsQosServiceFlowID INTEGER,
|
|
arrisMtadocsQosServiceClassName OCTET STRING,
|
|
arrisMtdocsQosServiceFlowDirection OCTET STRING,
|
|
arrisMtdocsQosServicePrimaryFlow OCTET STRING,
|
|
arrisMtadocsQosTrafficType OCTET STRING,
|
|
arrisMtadocsQosServicePackets INTEGER
|
|
}
|
|
|
|
arrisMtadocsQosServiceIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..100)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The index of mta qos entry."
|
|
::= { arrisMtadocsQosServiceEntry 1 }
|
|
|
|
arrisMtadocsQosServiceFlowID OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "mta qos service flow id."
|
|
::= { arrisMtadocsQosServiceEntry 2 }
|
|
|
|
arrisMtadocsQosServiceClassName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "mta qos service class name."
|
|
::= { arrisMtadocsQosServiceEntry 3 }
|
|
|
|
arrisMtdocsQosServiceFlowDirection OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "mta qos service flow direction."
|
|
::= { arrisMtadocsQosServiceEntry 4 }
|
|
|
|
arrisMtdocsQosServicePrimaryFlow OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "mta qos service primary flow"
|
|
::= { arrisMtadocsQosServiceEntry 5 }
|
|
|
|
arrisMtadocsQosTrafficType OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "mta qos traffic type."
|
|
::= { arrisMtadocsQosServiceEntry 6 }
|
|
|
|
arrisMtadocsQosServicePackets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Packets belong to the service."
|
|
::= { arrisMtadocsQosServiceEntry 7 }
|
|
|
|
arrisMtadocsQosDisableLoggin OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
disableLoggin (1),
|
|
enableLoggin (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "disable mta qos log collecting."
|
|
::= { arrisMtadocsQosService 2 }
|
|
|
|
arrisMtadocsQosLogClear OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Clear mta qos log. Always return true if get the value of this mib"
|
|
::= { arrisMtadocsQosService 3 }
|
|
|
|
arrisMtadocsQosShowDsxLogTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtadocsQosShowDsxLogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table contains the DSX log"
|
|
::= { arrisMtadocsQosService 4 }
|
|
|
|
arrisMtadocsQosShowDsxLogEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtadocsQosShowDsxLogEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in the log table."
|
|
INDEX { arrisMtadocsQosShowDsxLogIndex }
|
|
::= { arrisMtadocsQosShowDsxLogTable 1 }
|
|
|
|
ArrisMtadocsQosShowDsxLogEntry ::= SEQUENCE{
|
|
arrisMtadocsQosShowDsxLogIndex INTEGER,
|
|
arrisMtadocsQosShowDsxLog OCTET STRING
|
|
}
|
|
|
|
arrisMtadocsQosShowDsxLogIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..256)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The index of signal log."
|
|
::= { arrisMtadocsQosShowDsxLogEntry 1 }
|
|
|
|
arrisMtadocsQosShowDsxLog OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..2048))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Show the log of dsx"
|
|
::= { arrisMtadocsQosShowDsxLogEntry 2 }
|
|
|
|
-- PD 189252 end
|
|
|
|
arrisMtaDevOptionality8ChnlKey OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"When correct key is entered, 8 channel DSP operation can be enabled using
|
|
arrisMtaDevOptionality8ChnlEnable mib."
|
|
::= { arrisMtaDevOptionality 1 }
|
|
|
|
|
|
arrisMtaDevOptionality8ChnlEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2),
|
|
enabled-needs-to-be-reset(3),
|
|
disabled-needs-to-be-reset(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"Enable or Disable 8 channel DSP operation. Enabling requires presence
|
|
of a valid 8 Channel DSP Key. This key is entered via the
|
|
arrisMtaDevOptionality8ChnlKey MIB. When an Enable or Disable action
|
|
is invoked, a reset of the unit is required before the action becomes
|
|
effective. Until the reset occurs this MIB indicates the need for a
|
|
reset by displaying a status which includes _needs_to_be_reset. Note
|
|
that _needs_to_be_reset status values are not valid inputs to this MIB.
|
|
Valid MIB inputs are enabled(1) and disabled(2)"
|
|
::= { arrisMtaDevOptionality 2 }
|
|
|
|
|
|
arrisMtaDevOptionalityLoopDiagKey OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"When correct key is entered, Loop Diag can be performed."
|
|
::= { arrisMtaDevOptionality 3 }
|
|
|
|
|
|
arrisMtaDevLoopVoltageKey OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When correct key is entered, Loop Voltage Mgmt. policy can be set.
|
|
This MIB is only writable via configuration file."
|
|
::= { arrisMtaDevLoopVoltageMgmt 1 }
|
|
|
|
|
|
arrisMtaDevLoopVoltagePolicy OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
always-voltage-present(1),
|
|
rf-carrier-voltage-present(2),
|
|
in-service-voltage-present(3),
|
|
default-operation(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"1. Maintain loop idle voltage at all times.
|
|
2. Apply loop idle voltage at all times except when no RF QAM carrier is
|
|
detected. The intent of this policy option is to maintain idle
|
|
voltage for all normal operation but to remove it if RF conditions
|
|
appear to match a malicious cable cut (such may happen if a burglar is
|
|
trying to disable the alarm system).
|
|
3. Apply loop idle voltage only when the MTA device is In-service (MTA IP
|
|
address is received and valid config file has been received) and during
|
|
manually initiated resets (either reset button or SNMP). If this policy
|
|
criterion is selected, then the EMTA MUST maintain loop idle voltage if a
|
|
reset command is received (via SNMP or reset button or as part of a
|
|
management initiated software upgrade). Once the MTA has come back in-
|
|
service, any subsequent MTA out-of-service condition MUST result in
|
|
removal of loop idle voltage (except for another manually initiated reset).
|
|
As a failsafe, if the MTA has not come in-service within a provisionable
|
|
time, then loop idle voltage MUST be removed.
|
|
4. Apply loop idle voltage whenever the MTA device is in-service.
|
|
5. This MIB is only writable via configuration file."
|
|
DEFVAL { default-operation }
|
|
::= { arrisMtaDevLoopVoltageMgmt 2 }
|
|
|
|
|
|
arrisMtaDevLoopVoltageResetTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the time after which to remove loop voltage if the MTA has not come
|
|
in-service. Acceptable range is 8-1800 seconds. Stored value must be divisible
|
|
by 8 (any remainder will be discarded). See arrisMtaDevLoopVoltagePolicy 3 for
|
|
operational details.
|
|
This MIB is only writable via configuration file.
|
|
For D11PLUS builds, values from 8 through 32 will be multiplied by 3."
|
|
DEFVAL { 300 } -- ( = 5 minutes )
|
|
::= { arrisMtaDevLoopVoltageMgmt 3 }
|
|
|
|
arrisMtaDevLoopVoltageMaintTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Specifies the time that loop voltage will be supplied regardless of RF condition.
|
|
See arrisMtaDevLoopVoltagePolicy for more detailed information.
|
|
This MIB is only writable via configuration file."
|
|
DEFVAL { 0 } -- ( = 0 minutes )
|
|
::= { arrisMtaDevLoopVoltageMgmt 4 }
|
|
|
|
|
|
arrisMtaDevVPNomJitterBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
packetizationRatex1(1),
|
|
packetizationRatex2(2),
|
|
packetizationRatex3(3),
|
|
packetizationRatex4(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the Voice Playout nominal jitter buffer."
|
|
DEFVAL { packetizationRatex1 }
|
|
::= { arrisMtaDevOperationalSetup 1 }
|
|
|
|
arrisMtaDevVPJitterBufferMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
adaptive(1),
|
|
fixed(2),
|
|
auto(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the Voice Playout jitter buffer mode."
|
|
DEFVAL { adaptive }
|
|
::= { arrisMtaDevOperationalSetup 2 }
|
|
|
|
arrisMtaDevRTPTxQueueSize OBJECT-TYPE
|
|
SYNTAX INTEGER(2..20)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the RTP transmit queue size."
|
|
DEFVAL { 20 }
|
|
::= { arrisMtaDevOperationalSetup 3 }
|
|
|
|
arrisMtaDevEchoCancellerTailLength OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
eightMs(1),
|
|
thirtyTwoMs(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the length in milliseconds of the echo canceller tail. This object
|
|
is only settable during the processing of the MTA config file."
|
|
DEFVAL { thirtyTwoMs }
|
|
::= { arrisMtaDevOperationalSetup 4 }
|
|
|
|
arrisMtaDevDspHandleNonPhaseReversedTone OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
onECANEnable(2),
|
|
onECANDisabled(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set handling the DSP non phase reversed tone detection for modem. A value of
|
|
off(1) indicates the tone will not be handled. A default value of onECANEnable(2)
|
|
indicates the modem non phase reversed CED tone will be handled with echo canceller
|
|
enabled. A value of onECANDisabled(3) indicates the modem non phase reversed CED
|
|
tone will be handled with echo canceller disabled."
|
|
DEFVAL { onECANEnable }
|
|
::= { arrisMtaDevOperationalSetup 5 }
|
|
|
|
-- [ARRIS NOTE: For the published (publicly available) MIB, the MAX-ACCESS clause for
|
|
-- the 'arrisCmDevProvMethodIndicator' object should have a value of 'read-only'.]
|
|
arrisMtaDevProvMethodIndicator OBJECT-TYPE
|
|
SYNTAX ArrsMtaDevProvMethod
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the method used to provision the device. This object should only be
|
|
changed by the configuration file. The following provisioning methods are supported:
|
|
|
|
docsisOnly(0) - DOCSIS-only provisioning
|
|
|
|
fullPacketCable(1) - PacketCable 1.5 Flows. See
|
|
arrisMtaDevPacketcableProvisioningFlow for which
|
|
flow we are using.
|
|
|
|
packetCableMinusKDC(2) - same as 'fullPacketCable', except with IPSEC and
|
|
SNMPv3 disabled
|
|
|
|
cps(3) - compatible with CPS2000 (SNMPv2; IPSEC disabled)
|
|
|
|
gupi(4) - SNMPv2, with no SNMP Informs and IPSEC disabled
|
|
|
|
singleMAC(5) - single config file (SNMPv2, single IP address,
|
|
single MAC address, no SNMP Informs, IPSEC disabled
|
|
|
|
basic1(6) - Basic1 SNMPv2, without the SNMP Enrollment, Status Informs
|
|
or Hash
|
|
|
|
basic2(7) - ARRIS Basic2 SNMPv2, without the SNMP Enrollment Inform or
|
|
Hash
|
|
|
|
gupiEncryptedMtaConfig(8) - Same as gupi(4) above with the MTA config file encrypted
|
|
using an Arris proprietary method.
|
|
|
|
gupiMacMta(9) - gupi provisioning that uses MTA MAC address as the MTA config
|
|
file name. (ie- 1337c0ded00d.bin)
|
|
|
|
gupiEncryptedMacMta(10) - gupi encrypted mta config provisioning that uses MTA MAC address
|
|
as the MTA config file name. (ie- 1337c0ded00d.bin)
|
|
|
|
gupiTftpSvrOverride(11) - gupi provisioning where the FQDN of the MTA TFTP server is expected to
|
|
be present in the MIB arrisMtaDevTFTPServerAddrOverrideFQDN"
|
|
|
|
::= { arrisMtaDevOperationalSetup 6 }
|
|
|
|
arrisMtaCfgRTPDynPortStart OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This defines the starting value for a range of ports that will be used dynamically
|
|
when sending out SIP RTP voice packets. This MIB and arrisMtaCfgRTPDynPortEnd
|
|
are to be used together.
|
|
|
|
The range limit is 1024-65535. Where arrisMtaCfgRTPDynPortStart can be 1024 and
|
|
arrisMtaCfgRTPDynPortEnd can be 65535. The default range is 49152-65535.
|
|
However it should be noted that the IANA defines the following ranges:
|
|
|
|
The Well Known Ports are those from 0 through 1023.
|
|
The Registered Ports are those from 1024 through 49151.
|
|
The Dynamic and/or Private Ports are those from 49152 through 65535."
|
|
::= { arrisMtaDevOperationalSetup 7 }
|
|
|
|
arrisMtaCfgRTPDynPortEnd OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This defines the starting value for a range of ports that will be used dynamically
|
|
when sending out SIP RTP voice packets. This MIB and arrisMtaCfgRTPDynPortStart
|
|
are to be used together.
|
|
|
|
The range limit is 1024-65535. Where arrisMtaCfgRTPDynPortStart can be 1024 and
|
|
arrisMtaCfgRTPDynPortEnd can be 65535. The default range is 49152-65535.
|
|
However it should be noted that the IANA defines the following ranges:
|
|
|
|
The Well Known Ports are those from 0 through 1023.
|
|
The Registered Ports are those from 1024 through 49151.
|
|
The Dynamic and/or Private Ports are those from 49152 through 65535."
|
|
::= { arrisMtaDevOperationalSetup 8 }
|
|
|
|
arrisMtaDevVPMaxJitterBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
packetizationRatex1(1),
|
|
packetizationRatex2(2),
|
|
packetizationRatex3(3),
|
|
packetizationRatex4(4),
|
|
packetizationRatex5(5),
|
|
packetizationRatex6(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the Voice Playout maximum jitter buffer."
|
|
DEFVAL { packetizationRatex6 }
|
|
::= { arrisMtaDevOperationalSetup 9 }
|
|
|
|
arrisMtaDevPacketcableProvisioningFlow OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
secure (0),
|
|
hybrid2 (1),
|
|
hybrid1 (2),
|
|
basic2 (3),
|
|
basic1 (4),
|
|
none (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PacketCable simplified provisioning flow support for PC1.5 Compliance. This object
|
|
will be updated by the Provisioning Code. The following PC1.5 Compliant Provisioning
|
|
methods are supported:
|
|
|
|
secure (0) - PacketCable 1.5 Secure Flow
|
|
|
|
hybrid2 (1) - PacketCable 1.5 Hybrid 2 Flow
|
|
|
|
hybrid1 (2) - PacketCable 1.5 Hybrid 1 Flow
|
|
|
|
basic2 (3) - PacketCable 1.5 Basic 2 Flow
|
|
|
|
basic1 (4) - PacketCable 1.5 Basic 1 Flow
|
|
|
|
none (5) - ARRIS NON PacketCable 1.5 Flow"
|
|
DEFVAL { none }
|
|
::= { arrisMtaDevOperationalSetup 39 }
|
|
|
|
arrisMtaDevEnableIndexTenEleven OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object is used to enable telephone line indices ten and eleven
|
|
instead of telephone line indices nine and ten. Index ten will be the
|
|
mininum index for the MTA. The default value for this MIB object is disablel(0)."
|
|
::= { arrisMtaDevOperationalSetup 13 }
|
|
|
|
|
|
arrisMtaDevGainControlFSK OBJECT-TYPE
|
|
SYNTAX Integer32(-10..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for MTA generated FSK tones (CID and VMWI).
|
|
A value of 2 increases the FSK level by 2 dBm. A value of -2 decreases the FSK
|
|
level by 2 dBm."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevGainControl 1 }
|
|
|
|
arrisMtaDevGainControlCAS OBJECT-TYPE
|
|
SYNTAX Integer32(-2..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for MTA generated CAS tone.
|
|
A value of 2 increases the playout level by 2 dBm. A value of -2 decreases the playout
|
|
level by 2 dBm."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevGainControl 2 }
|
|
|
|
arrisMtaDevGainControlLocalTone OBJECT-TYPE
|
|
SYNTAX Integer32(-2..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for all MTA generated Call Progress tones
|
|
(Dialtone, Busytone, Ringback, etc.) toward the CPE. A value of 2 increases the
|
|
playout level by 2 dBm. A value of -2 decreases the playout level by 2 dBm. This MIB
|
|
does not effect CAS tone levels - use arrisMtaDevGainControlCAS for adjusting the
|
|
CAS tone."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevGainControl 3 }
|
|
|
|
arrisMtaDevGainControlNetworkTone OBJECT-TYPE
|
|
SYNTAX Integer32(-2..2)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for MTA generated Call Progress tones
|
|
toward the network (Ringback). A value of 2 increases the playout level by 2 dBm.
|
|
A value of -2 decreases the playout level by 2 dBm."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevGainControl 4 }
|
|
|
|
arrisMtaDevGainControlLocalDTMF OBJECT-TYPE
|
|
SYNTAX Integer32(-15..9)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for MTA generated DTMF tones toward
|
|
the local CPE (ex. DTMF CID). A value of 2 increases the playout level by 2 dBm.
|
|
A value of -2 decreases the playout level by 2 dBm."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevGainControl 5 }
|
|
|
|
arrisMtaDevGainControlNetworkDTMF OBJECT-TYPE
|
|
SYNTAX Integer32(-9..9)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for MTA generated DTMF tones
|
|
toward the network (ex. IPDT Pulse Dialing). A value of 2 increases the playout
|
|
level by 2 dBm. A value of -2 decreases the playout level by 2 dBm."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevGainControl 6 }
|
|
|
|
arrisMtaDevGainControlTxVoice OBJECT-TYPE
|
|
SYNTAX Integer32(-16..16)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for voice. A value of 2 increases
|
|
the voice level by 2 dBm. A value of -2 decreases the voice level by 2 dBm. This
|
|
value does not effect the levels of local tones or FSK.
|
|
NOTE: Use caution when changing this MIB. Increasing or decreasing the voice level
|
|
by the larger numbers allowed in the range may compromise voice quality."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevGainControl 7 }
|
|
|
|
arrisMtaDevGainControlRxVoice OBJECT-TYPE
|
|
SYNTAX Integer32(-16..16)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The receive digital gain adjustment (dBm) for voice. A value of 2 increases
|
|
the voice level by 2 dBm. A value of -2 decreases the voice level by 2 dBm.
|
|
NOTE: Use caution when changing this MIB. Increasing or decreasing the voice level
|
|
by the larger numbers allowed in the range may compromise voice quality."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevGainControl 8 }
|
|
|
|
arrisMtaDevLevelControlOffHookEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Allows for the use of the arrisMtaDevLevelControlOffHookFSK and
|
|
arrisMtaDevLevelControlOffHookCAS MIBs. When this is set to enable, those
|
|
MIBs will be replace the arrisMtaDevLevelControlFSK and
|
|
arrisMtaDevLevelControlCAS MIBs in off-hook situations."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevLevelControl 1 }
|
|
|
|
arrisMtaDevLevelControlOffHookFSK OBJECT-TYPE
|
|
SYNTAX Integer32(-32..-10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain setting (dBm) for MTA generated FSK tones (CID and VMWI)
|
|
while the line is off hook. The MIB can be adjusted in 1dBm increcements from a high
|
|
of -10dBm to a low of -32dBm. The arrisMtaDevLevelControlOffHookEnable MIB must
|
|
enabled to activate this MIB."
|
|
DEFVAL { -15 }
|
|
::= { arrisMtaDevLevelControl 2 }
|
|
|
|
arrisMtaDevLevelControlOffHookCAS OBJECT-TYPE
|
|
SYNTAX Integer32(-32..-10)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain setting (dBm) for MTA generated CAS tones (CID and VMWI)
|
|
while the line is off hook. The MIB can be adjusted in 1dBm increcements from a high
|
|
of -10dBm to a low of -32dBm. The arrisMtaDevLevelControlOffHookEnable MIB must
|
|
enabled to activate this MIB."
|
|
DEFVAL { -15 }
|
|
::= { arrisMtaDevLevelControl 3 }
|
|
|
|
-- arrisMtaDevEnableIndexTenEleven OBJECT-TYPE
|
|
-- SYNTAX INTEGER {
|
|
-- disable(0),
|
|
-- enable(1)
|
|
-- }
|
|
-- MAX-ACCESS read-write
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "This MIB object is used to enable telephone line indices ten and eleven
|
|
-- instead of telephone line indices nine and ten. Index ten will be the
|
|
-- mininum index for the MTA. The default value for this MIB object is disable(0)."
|
|
-- ::= { arrisMtaDevOperationalSetup 13 }
|
|
|
|
arrisMtaDevDspCpsSetting OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable or Disable the ECAN fast constant power signal detection. A default value of
|
|
on(2) makes the echo cancellor disengage immediately when a high level constant power
|
|
signal is detected. A value of off(1) will not disengage the ECAN when a high level
|
|
constant power signal is detected."
|
|
DEFVAL { on }
|
|
::= { arrisMtaDevOperationalSetup 14 }
|
|
|
|
arrisMtaDevVbdOverwriteLineBitmap OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When set, changes fax/modem jitter buffer settings for the selected line to the
|
|
VbdOverwriteJitterBuffer values entered in the config file.
|
|
(0) no line set, (0x1) line #1 set, (0x2) line #2 set, (0x4) line #3 set, ..."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevOperationalSetup 16 }
|
|
|
|
arrisMtaDevVbdOverwriteMinJitterBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER(10..160)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When used in conjuction with arrisMtaDevVbdOverwriteLineBitmap, this value will
|
|
be used as the minimun jitter buffer setting in all modem/fax calls for the selected
|
|
lines."
|
|
DEFVAL { 20 }
|
|
::= { arrisMtaDevOperationalSetup 17 }
|
|
|
|
arrisMtaDevVbdOverwriteNomJitterBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER(10..160)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When used in conjuction with arrisMtaDevVbdOverwriteLineBitmap, this value will
|
|
be used as the nominal jitter buffer setting in all modem/fax calls for the selected
|
|
lines."
|
|
DEFVAL { 70 }
|
|
::= { arrisMtaDevOperationalSetup 18 }
|
|
|
|
arrisMtaDevVbdOverwriteMaxJitterBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER(10..160)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When used in conjuction with arrisMtaDevVbdOverwriteLineBitmap, this value will
|
|
be used as the maximum jitter buffer setting in all modem/fax calls for the selected
|
|
lines."
|
|
DEFVAL { 160 }
|
|
::= { arrisMtaDevOperationalSetup 19 }
|
|
|
|
arrisMtaDevEventHideFQDNandIPAddress OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object is used to enable hide MTA fqdn and IP address on basic web page event log
|
|
. The default value for this MIB object is disable(0)."
|
|
::= { arrisMtaDevOperationalSetup 20 }
|
|
|
|
arrisMtaDevDhcpOptionOverride OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Typically the value received in the DHCP OFFER should not change in the DHCP ACK. DHCP
|
|
RENEW/REBIND values should be consistent with the value received in the DHCP OFFER. This
|
|
MIB object will Enable or Disable the DHCP option code 122/177 suboption 3 value enforcement.
|
|
A value of off(1) will enable DHCP option 122/177 suboption 3 value comparison
|
|
checking. A value of on(2) will disable the enforcement of DHCP option 122/177
|
|
suboption 3 value comparison checking.
|
|
The default value is off(1)."
|
|
DEFVAL { off }
|
|
::= { arrisMtaDevOperationalSetup 21 }
|
|
|
|
arrisMtaDevTFTPServerAddrOverrideFQDN OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FQDN of the TFTP Server that holds the MTA config file. This is used to override the default
|
|
TFTP Server. This can only be used with the gupiTftpSvrOverride(11) Provisioning Method."
|
|
::= { arrisMtaDevOperationalSetup 22}
|
|
|
|
arrisMtaDevDefaultReasonNoCIDName OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unavailable(0),
|
|
private(1),
|
|
sendnothing(2),
|
|
sdmf(3),
|
|
excludeName(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object determines what reason is sent to the CPE when the Caller ID Name is not included in the signal request.
|
|
The default value for this MIB object is 'O' for unavailable or outofarea(0). If the value of the MIB is set to private(1)
|
|
then 'P' is sent to the CPE. The value of sendnothing(2) tells the MTA to send NULL reason for the missing name.
|
|
The value of sdmf(3) sends the number only in NA SDMF format. The value of excludeName(4) tells the MTA to not include
|
|
any name parameters or reason for missing name."
|
|
::= { arrisMtaDevOperationalSetup 23 }
|
|
|
|
arrisMtaDevSipConfigFileURL OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The URL of the SIP configuration file for redownloading provisioning and
|
|
configuration parameters to this device."
|
|
::= { arrisMtaDevOperationalSetup 24 }
|
|
|
|
arrisMtaDevSipDwnldConfig OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enable a redownload of the SIP configuration file parameters specified via
|
|
the configuration file URL obtained in the MIB object arrisMtaDevSipConfigFileURL.
|
|
When read this MIB object will always return a value of off(1)."
|
|
DEFVAL { off }
|
|
::= { arrisMtaDevOperationalSetup 25 }
|
|
|
|
arrisMtaDevSpecialConfigurationOverrideEnable OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
enableDhcpOption60SubOpt18Ovrd(0),
|
|
unused1(1),
|
|
unused2(2),
|
|
unused3(3),
|
|
unused4(4),
|
|
unused5(5),
|
|
unused6(6),
|
|
unused7(7),
|
|
unused8(8),
|
|
unused9(9),
|
|
unused10(10),
|
|
unused11(11),
|
|
unused12(12),
|
|
unused13(13),
|
|
unused14(14),
|
|
unused15(15),
|
|
unused16(16),
|
|
unused17(17),
|
|
unused18(18),
|
|
unused19(19),
|
|
unused20(20),
|
|
unused21(21),
|
|
unused22(22),
|
|
unused23(23),
|
|
unused24(24),
|
|
unused25(25),
|
|
unused26(26),
|
|
unused27(27),
|
|
unused28(28),
|
|
unused29(29),
|
|
unused30(30),
|
|
unused31(31)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to enable proprietary features of the Arris MTA
|
|
From left to right, the specified bit indicates whether or not
|
|
the corresponding MTA feature is enabled. For example, if the first
|
|
bit is set, then the enableDhcpOption60SubOpt18Ovrd feature is enabled. If
|
|
it is zero, the feature is disabled. NO bits are set by default.
|
|
Field is 32 bits long and all 32 bits must be written.
|
|
|
|
/** BIT Descriptions **/
|
|
0x80000000 : enableDhcpOption60SubOpt18Ovrd - Enable DHCP Option 60 SubOption 18 override
|
|
0x40000000 : Reserved for Future.
|
|
0x20000000 : Reserved for Future.
|
|
0x10000000 : Reserved for Future.
|
|
0x08000000 : Reserved for Future.
|
|
0x04000000 : Reserved for Future.
|
|
0x02000000 : Reserved for Future.
|
|
0x01000000 : Reserved for Future.
|
|
0x00800000 : Reserved for Future.
|
|
0x00400000 : Reserved for Future.
|
|
0x00200000 : Reserved for Future.
|
|
0x00100000 : Reserved for Future.
|
|
0x00080000 : Reserved for Future.
|
|
0x00040000 : Reserved for Future.
|
|
0x00020000 : Reserved for Future.
|
|
0x00010000 : Reserved for Future.
|
|
0x00008000 : Reserved for Future.
|
|
0x00004000 : Reserved for Future.
|
|
0x00002000 : Reserved for Future.
|
|
0x00001000 : Reserved for Future.
|
|
0x00000800 : Reserved for Future.
|
|
0x00000400 : Reserved for Future.
|
|
0x00000200 : Reserved for Future.
|
|
0x00000100 : Reserved for Future.
|
|
0x00000080 : Reserved for Future.
|
|
0x00000040 : Reserved for Future.
|
|
0x00000020 : Reserved for Future.
|
|
0x00000010 : Reserved for Future.
|
|
0x00000008 : Reserved for Future.
|
|
0x00000004 : Reserved for Future.
|
|
0x00000002 : Reserved for Future.
|
|
0x00000001 : Reserved for Future."
|
|
DEFVAL { '00000000'h }
|
|
::= { arrisMtaDevOperationalSetup 26 }
|
|
|
|
arrisMtaDevRtcpTosValue OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This value determines what value is used in the IP TOS byte for RTCP packets."
|
|
::= { arrisMtaDevOperationalSetup 27 }
|
|
|
|
arrisMtaDevAutomaticOsiDelay OBJECT-TYPE
|
|
SYNTAX Integer32(0..100)
|
|
UNITS "100 milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This MIB defines the time, in 100ms increments, to wait after a DLCX is received before determining if an automatic OSI should be generated by the MTA to force a line disconnect.
|
|
The default time is 5 seconds. A value of 0 would cause the OSI to be sent immediately (if there are no other connections on the line). The ppCfgMtaCallpFeatureSwitch must have the 0x20000000 bit set for this feature to be enabled."
|
|
DEFVAL { 50 }
|
|
::= { arrisMtaDevOperationalSetup 28 }
|
|
|
|
arrisMtaDevCustomJitterBufferEnabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enables ability to customize jitter buffer settings using the CustomMinJitterBuffer, CustomNomJitterBuffer and CustomMaxJitterBuffer
|
|
mibs. When this setting is off, the jitter buffer will be determined using the arrisMtaDevVPNomJitterBuffer and
|
|
arrisMtaDevVPMaxJitterBuffer mibs and defaults to min=nom=[(packet rate *1) + 5] and max = [(packet rate * 3) + 5] msecs.
|
|
When set to on, the custom jitter buffer settings will default to 5-10-60 if no custom value is set using the CustomMinJitterBuffer,
|
|
CustomNomJitterBuffer and CustomMaxJitterBuffer mibs."
|
|
DEFVAL { off }
|
|
::= { arrisMtaDevOperationalSetup 29 }
|
|
|
|
arrisMtaDevCustomMinJitterBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER (5..160)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the customized voice playout minimum jitter buffer to be used when the arrisMtaDevCustomJitterBufferEnabled is set to on.
|
|
Valid range is 5-160 in increments of 5"
|
|
DEFVAL { 5 }
|
|
::= { arrisMtaDevOperationalSetup 30 }
|
|
|
|
arrisMtaDevCustomNomJitterBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER (5..160 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the customized voice playout nominal jitter buffer to be used when the arrisMtaDevCustomJitterBufferEnabled is set to on.
|
|
Valid range is 5-160 in increments of 5"
|
|
DEFVAL { 10 }
|
|
::= { arrisMtaDevOperationalSetup 31 }
|
|
|
|
arrisMtaDevCustomMaxJitterBuffer OBJECT-TYPE
|
|
SYNTAX INTEGER (5..160)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the customized voice playout maximum jitter buffer to be used when the arrisMtaDevCustomJitterBufferEnabled is set to on.
|
|
Valid range is 5-160 in increments of 5"
|
|
DEFVAL { 120 }
|
|
::= { arrisMtaDevOperationalSetup 32 }
|
|
|
|
arrisMtaDevEnableDHCPLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to enable/disable MTA DHCP logging."
|
|
::= { arrisMtaDevOperationalSetup 33 }
|
|
|
|
arrisMtaDevEnableMGCPLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to enable/disable CallP Signalling logging"
|
|
::= { arrisMtaDevOperationalSetup 34 }
|
|
|
|
arrisMtaDevClearDHCPLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clear(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to Clear the MTA DHCP Logs."
|
|
::= { arrisMtaDevOperationalSetup 35 }
|
|
|
|
arrisMtaDevClearMGCPLog OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clear(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to Clear the MTA MGCP Logs."
|
|
::= { arrisMtaDevOperationalSetup 36 }
|
|
|
|
arrisMtaDevTDDReportToCMS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Allows configuration of whether TDD detection events are reported to CMS."
|
|
DEFVAL { enable }
|
|
::= { arrisMtaDevOperationalSetup 37 }
|
|
|
|
arrisMtaDevAutomaticCallResourceRecovery OBJECT-TYPE
|
|
SYNTAX Integer32(0..3600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "MIB defines the number of seconds to delay upon an on-hook event before detecting
|
|
that all resources acquired while a call was active need to be recovered on a line
|
|
in the IDLE state. A value of 0 disables the automatic feature."
|
|
::= { arrisMtaDevOperationalSetup 38 }
|
|
|
|
arrisMtaDevOffHookFskDelay OBJECT-TYPE
|
|
SYNTAX Integer32(0..500)
|
|
UNITS "milliseconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MIB defines the time (in milliseconds) to delay before sending the FSK to the CPE.
|
|
The delay starts upon receiving the ACK (DTMF D) from the CPE in response to the CAS tone for
|
|
Call Waiting (or Type 2) Caller ID."
|
|
::= { arrisMtaDevOperationalSetup 41 }
|
|
|
|
arrisMtaDevT38Timeout OBJECT-TYPE
|
|
SYNTAX Integer32(1..30)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Allows configuration of the T38 timeout, during which time the audio is muted, before T38
|
|
failure events are reported to CMS."
|
|
DEFVAL { 30 }
|
|
::= { arrisMtaDevOperationalSetup 42 }
|
|
|
|
arrisMtaDevSuperG3FaxRelay OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Allows configuration of SuperG3 fax processing upon detection of the V21 CM or V.8 data signal.
|
|
When disabled, the MTA still detects the signaling for SuperG3 fax and the signal is used to
|
|
setup the endpoint for SuperG3 pass-thru fax transmission via G711. When enabled the MTA handles
|
|
the detection of SuperG3 signaling to trigger the start of T.38 process. The negotiation during
|
|
call setup determines whether or not T.38 can be used to send the fax."
|
|
DEFVAL { disable }
|
|
::= { arrisMtaDevOperationalSetup 43 }
|
|
|
|
arrisMtaDevDTMFEndEventForceAscending OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to enable/disable RFC 2833 DTMF end event duration force ascending."
|
|
DEFVAL { disable }
|
|
::= { arrisMtaDevOperationalSetup 44 }
|
|
|
|
arrisMtaDevDspHandleBellModemTone OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set the DSP to detect the Bell Modem Tone (2225kHz). The Bell Modem Tone is
|
|
frequently used by older data modems, usually in low speed setups. When this
|
|
MIB is set to enable(1), the DSP will detect the Bell Modem Tone from either the
|
|
local or network end. When this MIB is set to disable(0), the tone will be ignored."
|
|
DEFVAL { disable }
|
|
::= { arrisMtaDevOperationalSetup 45 }
|
|
|
|
arrisMtaDevDhcpSubOpt3Immediate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(1),
|
|
on(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object will control the comparison/handling of MTA DHCP Opt 122 SubOpt 3.
|
|
A value of off(1) will disable DHCP option 122 suboption 3 comparison/handling on the fly.
|
|
A value of on(2) will enable DHCP option 122 suboption 3 comparison/handling on the fly.
|
|
SNMP notifications will be sent to the new Provisioning SNMP Entity.
|
|
The default value is off(1)."
|
|
DEFVAL { off }
|
|
::= { arrisMtaDevOperationalSetup 46 }
|
|
|
|
|
|
arrisMtaDevMaxCallPServiceFlows OBJECT-TYPE
|
|
SYNTAX Integer32(0..64)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to limit the number of calls (service flows). Outgoing calls, incoming calls,
|
|
and conference call legs are included in this count. The EMTA ports are able to
|
|
call each other without this limitation. Default value 0 means disable this feature."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevOperationalSetup 47 }
|
|
|
|
--
|
|
-- The following MIBs control HD Voice Options
|
|
--
|
|
|
|
arrisMtaDevHDAudioDefaultPayloadType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static(0),
|
|
dynamic(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The setting of this MIB provisions the MTA to offer the G722 codec with the defined
|
|
static payload of (9)or a payload in the dynamic range of (96-127). This MIB setting is persistent."
|
|
DEFVAL { static }
|
|
::= { arrisMtaDevOperationalSetup 49}
|
|
|
|
arrisMtaDevWBSLIC OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The setting of this MIB sets the SLIC and DSP to WB mode. This MIB setting is persistent.
|
|
This MIB should be set from the CM configuration file. If this MIB value is altered in the
|
|
CM configuration file then the modem will reboot automatically after the change is applied.
|
|
A SNMP set after provisioning will take effect after the next reboot."
|
|
DEFVAL { disable }
|
|
::= { arrisMtaDevOperationalSetup 50}
|
|
|
|
arrisMtaDevProvisionedCodecArray OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is the list of codecs offered in the SDP as well as codecs returned in capabilities
|
|
for an AUEP response.
|
|
This MIB is only used with NCS signaling.
|
|
These are entered as a string separated by semi-colon ';' or comma ',' for example
|
|
'PCMU;PCMA;G726-32;telephone-event'.
|
|
This object should only be changed by the configuration file.
|
|
|
|
The default string will be NULL. A NULL string will result in consistent operation to previous
|
|
FW releases where all supported codecs are listed. "
|
|
::= { arrisMtaDevOperationalSetup 51 }
|
|
|
|
arrisMtaDevHDAudioG722SampleRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
rate8000(0),
|
|
rate16000(1),
|
|
rateDynamic(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB controls the SampleRate advertised in the rtpmap for the HD codec G722.
|
|
The actual sample rate is 16000 however for backward compatibility with RFC 1890
|
|
the default is 8000. The dynamic selection is to set the sample rate to the same
|
|
value received in SDP for the G722 codec.
|
|
|
|
Examples:
|
|
a=rtpmap: 99 G722-64/8000
|
|
a=rtpmap: 99 G722-64/16000"
|
|
DEFVAL { rate8000 }
|
|
::= { arrisMtaDevOperationalSetup 52}
|
|
|
|
arrisMtaDevHDAudioEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The setting of this MIB enables the MTA to support HD Audio codecs such as G722."
|
|
DEFVAL { enable }
|
|
::= { arrisMtaDevOperationalSetup 53}
|
|
|
|
arrisMtaDevRtcpJitterDisabled OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(0),
|
|
on(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The setting of this MIB disables the MTA to report the real Jitter value in the RTCP packet."
|
|
DEFVAL { off }
|
|
::= { arrisMtaDevOperationalSetup 54}
|
|
|
|
arrisMtaDevDiagLoopTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevDiagLoopEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Arris Touchstone specific per line loop diagnostic details"
|
|
::= { arrisMtaDevDiag 1 }
|
|
|
|
arrisMtaDevDiagLoopEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevDiagLoopEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each end point entry represents one telephone line"
|
|
INDEX { arrisMtaDevDiagLoopIndex }
|
|
::= { arrisMtaDevDiagLoopTable 1 }
|
|
|
|
ArrisMtaDevDiagLoopEntry ::= SEQUENCE {
|
|
arrisMtaDevDiagLoopIndex Integer32,
|
|
arrisMtaDevDiagLoopTime DisplayString,
|
|
arrisMtaDevDiagLoopRequest TruthValue,
|
|
arrisMtaDevDiagLoopLastResult INTEGER,
|
|
arrisMtaDevDiagLoopHazardousPotentialTest DisplayString,
|
|
arrisMtaDevDiagLoopForeignEmfTest DisplayString,
|
|
arrisMtaDevDiagLoopResistiveFaultsTest DisplayString,
|
|
arrisMtaDevDiagLoopReceiverOffHookTest DisplayString,
|
|
arrisMtaDevDiagLoopRingerTest DisplayString }
|
|
|
|
arrisMtaDevDiagLoopIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The unique value which identifies the port."
|
|
::= { arrisMtaDevDiagLoopEntry 1 }
|
|
|
|
|
|
arrisMtaDevDiagLoopTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Reports the time & date when loop diagnostics
|
|
were last run on the selected line. (Patent Pending)"
|
|
::= { arrisMtaDevDiagLoopEntry 2 }
|
|
|
|
arrisMtaDevDiagLoopRequest OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Setting this value to true will send a
|
|
diagnostics request on the line. Reading this
|
|
value will always return false. The
|
|
maintenance state of the line indicates
|
|
if diagnostics are being run on the line.
|
|
Note: Currently supported on TM402 only. (Patent Pending)"
|
|
::= { arrisMtaDevDiagLoopEntry 3 }
|
|
|
|
arrisMtaDevDiagLoopLastResult OBJECT-TYPE
|
|
SYNTAX INTEGER{diagnostics-passed(1),hazardous-potential-test-failure(2),
|
|
foreign-emf-test-failure(3),resistive-faults-test-failure(4),
|
|
receiver-offhook-test-failure(5), ringer-test-failure(6),
|
|
invalid-state-to-init-diags(7), line-is-unprovisioned(8),
|
|
diagnostics-results-pending(9), not-started(10),
|
|
unsupported(11), ringer-test-warning(12) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Start loop diag testing with arrisMtaDevDiagLoopRequest.
|
|
Thereafter reading this MIB provides current status. When testing
|
|
is complete, the status will be either all-loop-diags-passed
|
|
or the first test failed will be indicated. (Patent Pending)"
|
|
::= { arrisMtaDevDiagLoopEntry 4 }
|
|
|
|
arrisMtaDevDiagLoopHazardousPotentialTest OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Displays the hazardous-potential-test result for the last
|
|
time that loop diags were run. (Patent Pending)"
|
|
::= { arrisMtaDevDiagLoopEntry 5 }
|
|
|
|
arrisMtaDevDiagLoopForeignEmfTest OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Displays the foreign-emf-test result for the last
|
|
time that loop diags were run. (Patent Pending)"
|
|
::= { arrisMtaDevDiagLoopEntry 6 }
|
|
|
|
arrisMtaDevDiagLoopResistiveFaultsTest OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Displays the resistive-faults-test result for the last
|
|
time that loop diags were run. (Patent Pending)"
|
|
::= { arrisMtaDevDiagLoopEntry 7 }
|
|
|
|
arrisMtaDevDiagLoopReceiverOffHookTest OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Displays the receiver-offhook-test result for the last
|
|
time that loop diags were run. (Patent Pending)"
|
|
::= { arrisMtaDevDiagLoopEntry 8 }
|
|
|
|
arrisMtaDevDiagLoopRingerTest OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Displays the ringer-test result for the last
|
|
time that loop diags were run. (Patent Pending)"
|
|
::= { arrisMtaDevDiagLoopEntry 9 }
|
|
|
|
arrisMtaDevCmIpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevCmIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ARRIS proprietary IP Address table used for getting
|
|
CM IP address and physical address from MTA."
|
|
::= { arrisMtaDevCmIp 1 }
|
|
|
|
arrisMtaDevCmIpEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevCmIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each entry contains one IP address and one physical address."
|
|
INDEX { arrisMtaDevCmIpIndex }
|
|
::= { arrisMtaDevCmIpTable 1 }
|
|
|
|
ArrisMtaDevCmIpEntry ::= SEQUENCE {
|
|
arrisMtaDevCmIpIndex Integer32,
|
|
arrisMtaDevCmIpAddressType InetAddressType,
|
|
arrisMtaDevCmIpAddress InetAddress,
|
|
arrisMtaDevCmIpPhysAddress PhysAddress
|
|
}
|
|
|
|
arrisMtaDevCmIpIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (0..0)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Index used to order the arrisMtaDevCmIpTable entries.
|
|
Currently, CM only supports single IP address, thus
|
|
there would be no more than 1 entry in arrisMtaDevCmIpTable"
|
|
::= { arrisMtaDevCmIpEntry 1 }
|
|
|
|
arrisMtaDevCmIpAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of arrisMtaDevCmIpAddress."
|
|
::= { arrisMtaDevCmIpEntry 2 }
|
|
|
|
arrisMtaDevCmIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CM IP address."
|
|
::= { arrisMtaDevCmIpEntry 3 }
|
|
|
|
arrisMtaDevCmIpPhysAddress OBJECT-TYPE
|
|
SYNTAX PhysAddress (SIZE(0..65535))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CM physical address."
|
|
::= { arrisMtaDevCmIpEntry 4 }
|
|
|
|
arrisMtaDevEndPntTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevEndPntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Arris Touchstone specific per line provisioning details"
|
|
::= { arrisMtaDevEndPntSetup 3 }
|
|
|
|
arrisMtaDevEndPntEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevEndPntEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each end point entry represents one telephone line"
|
|
INDEX { arrisMtaDevEndPntIndex }
|
|
::= { arrisMtaDevEndPntTable 1 }
|
|
|
|
ArrisMtaDevEndPntEntry ::= SEQUENCE {
|
|
arrisMtaDevEndPntIndex Integer32,
|
|
arrisMtaDevEndPntDialingMethod INTEGER,
|
|
arrisMtaDevEndPntRingingWaveform INTEGER,
|
|
arrisMtaDevEndPntFaxOnlyLineTimeout Integer32,
|
|
arrisMtaDevPersistentLineStatus INTEGER,
|
|
arrisMtaDevEndPntCallWaitingRepeatSteady INTEGER,
|
|
arrisMtaDevEndPntCIDEnable INTEGER,
|
|
arrisMtaDevEndPntCIDNameEnable INTEGER,
|
|
arrisMtaDevEndPntCIDDateTimeEnable INTEGER,
|
|
arrisMtaDevEndPntLoopReversal INTEGER,
|
|
arrisMtaDevEndPntGainControlTxVoice INTEGER,
|
|
arrisMtaDevEndPntGainControlRxVoice INTEGER,
|
|
arrisMtaDevEndPntHDAudioEnable INTEGER,
|
|
arrisMtaDevEndPntHDAudioStatus INTEGER,
|
|
arrisMtaDevEndPntCallPState INTEGER
|
|
}
|
|
|
|
arrisMtaDevEndPntIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The unique value which identifies the port."
|
|
::= { arrisMtaDevEndPntEntry 1 }
|
|
|
|
arrisMtaDevEndPntDialingMethod OBJECT-TYPE
|
|
SYNTAX INTEGER { tone(1), pulse(2), toneAndPulse(3), pulseWithDTMFRelay(4), toneAndPulseWithDTMFRelay(5) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the method used to dial the digits for this telephony
|
|
endpoint. If tone(1), tone dialing (DTMF) is used. If pulse(2),
|
|
dial-pulse signaling is used to dial the digits, Tone dialing(DTMF) is
|
|
disabled. If Tone & Pulse(3), tone dialing(DTMF) and dial-pulse signaling
|
|
is used to dial the digits. If Pulse with DTMF relay(4), Tone dialing(DTMF)
|
|
is disabled, and pulse dialed digits will be relayed in-band to the media
|
|
gateway. If Tone & Pulse with DTMF relay(5), Tone dialing (DTMF) is enable,
|
|
and pulse dialed digits will be relayed in-band to the media gateway.
|
|
NOTE: (4) & (5) will require IPDT solution as well as DTMF support by the
|
|
Media gateway. The default value for this object is tone(1)."
|
|
DEFVAL { tone }
|
|
::= { arrisMtaDevEndPntEntry 24 }
|
|
|
|
arrisMtaDevEndPntRingingWaveform OBJECT-TYPE
|
|
SYNTAX INTEGER { normal(1), sinusoidal(2) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Indicates the voltage waveform used when ringing this telephony
|
|
endpoint. If normal(1) is used the standard waveform will be applied.
|
|
If sinusoidal(2) is specified, extra waveshaping will be performed. This
|
|
is for use with telephones that exhibit increased sensitivity to the ring
|
|
voltage waveform. The default value for this object is normal(1)."
|
|
DEFVAL { normal }
|
|
::= { arrisMtaDevEndPntEntry 25 }
|
|
|
|
arrisMtaDevEndPntFaxOnlyLineTimeout OBJECT-TYPE
|
|
SYNTAX Integer32 (0..600)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is used to define a line as a fax only line for NCS. The default value of the
|
|
object is zero which means no timeout. When the object is set to a non-zero value
|
|
a timer is started after the RTP mode becomes sendReceive. If this timer pops without
|
|
having received fax/modem tones on the connection the call will be dropped. Its
|
|
units are in seconds."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevEndPntEntry 26 }
|
|
|
|
arrisMtaDevPersistentLineStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ignore(0),
|
|
forceDisable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set persistent line status. This MIB and the ifAdminStatus MIB impact the
|
|
line status. If ignore(0) is set, the line status will be based on the
|
|
setting of ifAdminStatus in the MTA Config File. If ifAdminStatus is
|
|
not set in the MTA Config File, then the ifAdminStatus will be set to the
|
|
default value. The default value is up(1) if the line is provisioned and
|
|
down(2) if the line is not provisioned.
|
|
If this MIB is set to forceDisable(1), the service status of the line is set to
|
|
DOWN and the line state is set to EP_OOS after a reset. This MIB is always
|
|
ignored in a Config File. This MIB will be set to ignore(0) if the
|
|
arrisMtaDevRestoreNvmFactoryDefault is set to clear(1)."
|
|
DEFVAL { ignore }
|
|
::= { arrisMtaDevEndPntEntry 27 }
|
|
|
|
arrisMtaDevEndPntCallWaitingRepeatSteady OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When enabled(1), it indicates that the call waiting tone should repeat forever.
|
|
If disabled(0), it concludes using the finite rules."
|
|
DEFVAL { disable }
|
|
::= { arrisMtaDevEndPntEntry 28 }
|
|
|
|
arrisMtaDevEndPntCIDEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to enable/disable the All the Caller ID field send to phone.
|
|
If it's diabled, no Caller ID information will be sent."
|
|
DEFVAL { enable }
|
|
::= { arrisMtaDevEndPntEntry 29 }
|
|
|
|
arrisMtaDevEndPntCIDNameEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to enable/disable the Name part of CallerID field send to phone."
|
|
DEFVAL { enable }
|
|
::= { arrisMtaDevEndPntEntry 30 }
|
|
|
|
arrisMtaDevEndPntCIDDateTimeEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Used to enable/disable the Date/Time part of CallerID field send to phone."
|
|
DEFVAL { enable }
|
|
::= { arrisMtaDevEndPntEntry 31 }
|
|
|
|
arrisMtaDevEndPntLoopReversal OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This mib is used to manage loop polarity/reversal. When enabled(1), it indicates that
|
|
the line should be reversed to normal once the originating party hangs up first.
|
|
If disabled(0), the loop keeps on being reversed while the originating party hangs up."
|
|
DEFVAL { disable }
|
|
::= { arrisMtaDevEndPntEntry 32 }
|
|
|
|
arrisMtaDevEndPntGainControlTxVoice OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
dBm16(16),
|
|
dBm15(15),
|
|
dBm14(14),
|
|
dBm13(13),
|
|
dBm12(12),
|
|
dBm11(11),
|
|
dBm10(10),
|
|
dBm9(9),
|
|
dBm8(8),
|
|
dBm7(7),
|
|
dBm6(6),
|
|
dBm5(5),
|
|
dBm4(4),
|
|
dBm3(3),
|
|
dBm2(2),
|
|
dBm1(1),
|
|
dBm0(0),
|
|
dBm-1(-1),
|
|
dBm-2(-2),
|
|
dBm-3(-3),
|
|
dBm-4(-4),
|
|
dBm-5(-5),
|
|
dBm-6(-6),
|
|
dBm-7(-7),
|
|
dBm-8(-8),
|
|
dBm-9(-9),
|
|
dBm-10(-10),
|
|
dBm-11(-11),
|
|
dBm-12(-12),
|
|
dBm-13(-13),
|
|
dBm-14(-14),
|
|
dBm-15(-15),
|
|
dBm-16(-16),
|
|
disabled(-128)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for voice for a specific endpoint.
|
|
When set to a value other than disabled(-128), this MIB supersedes the
|
|
arrisMtaDevGainControlTxVoice MIB. A value of 2 increases
|
|
the voice level by 2 dBm. A value of -2 decreases the voice level by 2 dBm. This
|
|
value does not effect the levels of local tones or FSK.
|
|
Setting this MIB to disabled(-128) will disable this MIB and the Tx Voice Gain will
|
|
now be set by the arrisMtaDevGainControlTxVoice MIB.
|
|
NOTE: Use caution when changing this MIB. Increasing or decreasing the voice level
|
|
by the larger numbers allowed in the range may compromise voice quality."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevEndPntEntry 33 }
|
|
|
|
arrisMtaDevEndPntGainControlRxVoice OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dBm16(16),
|
|
dBm15(15),
|
|
dBm14(14),
|
|
dBm13(13),
|
|
dBm12(12),
|
|
dBm11(11),
|
|
dBm10(10),
|
|
dBm9(9),
|
|
dBm8(8),
|
|
dBm7(7),
|
|
dBm6(6),
|
|
dBm5(5),
|
|
dBm4(4),
|
|
dBm3(3),
|
|
dBm2(2),
|
|
dBm1(1),
|
|
dBm0(0),
|
|
dBm-1(-1),
|
|
dBm-2(-2),
|
|
dBm-3(-3),
|
|
dBm-4(-4),
|
|
dBm-5(-5),
|
|
dBm-6(-6),
|
|
dBm-7(-7),
|
|
dBm-8(-8),
|
|
dBm-9(-9),
|
|
dBm-10(-10),
|
|
dBm-11(-11),
|
|
dBm-12(-12),
|
|
dBm-13(-13),
|
|
dBm-14(-14),
|
|
dBm-15(-15),
|
|
dBm-16(-16),
|
|
disabled(-128)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The transmit digital gain adjustment (dBm) for voice for a specific endpoint.
|
|
When set to a value other than disabled(-128), this MIB supersedes the
|
|
arrisMtaDevGainControlRxVoice MIB. A value of 2 increases
|
|
the voice level by 2 dBm. A value of -2 decreases the voice level by 2 dBm. This
|
|
value does not effect the levels of local tones or FSK.
|
|
Setting this MIB to disabled(-128) will disable this MIB and the Rx Voice Gain will
|
|
now be set by the arrisMtaDevGainControlRxVoice MIB.
|
|
NOTE: Use caution when changing this MIB. Increasing or decreasing the voice level
|
|
by the larger numbers allowed in the range may compromise voice quality."
|
|
DEFVAL { 0 }
|
|
::= { arrisMtaDevEndPntEntry 34 }
|
|
|
|
arrisMtaDevEndPntHDAudioEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The setting of this MIB sets an individual line to support HD Audio codecs such as G722.
|
|
The MTA MIB setting for arrisMtaDevHDAudioEnable can override the individual line setting.
|
|
This MIB is persistent when modified post provisioning."
|
|
DEFVAL { enable }
|
|
::= { arrisMtaDevEndPntEntry 35 }
|
|
|
|
arrisMtaDevEndPntHDAudioStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1),
|
|
notprovisioned(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this MIB to read the effective status of HD Audio for an endpoint."
|
|
::= { arrisMtaDevEndPntEntry 36 }
|
|
|
|
arrisMtaDevEndPntCallPState OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
none(0),
|
|
out-of-service(1),
|
|
redialing(2),
|
|
idle(3),
|
|
predial(4),
|
|
dialing(5),
|
|
calling(6),
|
|
ringing(7),
|
|
connected(8),
|
|
waithook(9),
|
|
connected-alerting(10),
|
|
call-waiting(11),
|
|
three-way-calling(12),
|
|
conference(13),
|
|
predial-holding(14),
|
|
dialing-holding(15),
|
|
calling-holding(16),
|
|
waithook-holding(17),
|
|
waithook-alerting(18),
|
|
flash-digit(19),
|
|
stranded-call(20),
|
|
conf-before-answer(21),
|
|
autocall-ringing(22),
|
|
emergency-inject(23),
|
|
wait-reg(24),
|
|
restart(25),
|
|
disconnected(26),
|
|
inservice(27)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use this MIB to read the status of callp state"
|
|
::= { arrisMtaDevEndPntEntry 37 }
|
|
|
|
arrisMtaDevBatteryChargerFWRev OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The firmware rev of the battery charger."
|
|
::= { arrisMtaDevPwrSupplyBase 1 }
|
|
|
|
arrisMtaDevPwrSupplyBatteryTestTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present value of the Test Timer Scheduler expressed in days. If the value
|
|
read is 0xFF (255), the timer has been paused."
|
|
::= { arrisMtaDevPwrSupplyStats 4 }
|
|
|
|
arrisMtaDevPwrSupplyRatedBatCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The rated capacity of the battery that is currently installed. The value is
|
|
expressed in units of energy (10 watt*minutes/count), rather than charge
|
|
(amp*hours)."
|
|
::= { arrisMtaDevPwrSupplyStats 5 }
|
|
|
|
arrisMtaDevPwrSupplyTestedBatCapacity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The measured battery capacity expressed in 10 watt*minutes/count as determined
|
|
by the last battery test cycle."
|
|
::= { arrisMtaDevPwrSupplyStats 6 }
|
|
|
|
arrisMtaDevPwrSupplyBatStateOfCharge OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present battery state of charge expressed in 10 watt*minutes/count.
|
|
This value is approximate and is re-calibrated following a battery test cycle."
|
|
::= { arrisMtaDevPwrSupplyStats 7 }
|
|
|
|
arrisMtaDevPwrSupplyReadBatteryPwr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present load power expressed in 50mW/count and is an eight-second
|
|
moving average. This is the power being removed or applied to the battery.
|
|
Power is being removed while AC is not present or during the battery test.
|
|
Power is being applied if battery is being charged."
|
|
::= { arrisMtaDevPwrSupplyStats 8 }
|
|
|
|
arrisMtaDevPwrSupplySecondsOnBattery OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The present value of time expired since AC Failed and running on the battery."
|
|
::= { arrisMtaDevPwrSupplyStats 9 }
|
|
|
|
arrisMtaDevPwrSupplyBatRatedMinutes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the rated run-time on the battery based upon the unit's
|
|
typical idle power and the rated capacity of the battery when fully charged."
|
|
::= { arrisMtaDevPwrSupplyStats 10 }
|
|
|
|
arrisMtaDevPwrSupplyBatAvailableMinutes OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the available run-time on the battery based upon the unit's
|
|
typical idle power and the tested capacity of the battery when fully charged."
|
|
::= { arrisMtaDevPwrSupplyStats 11 }
|
|
|
|
arrisMtaDevPwrSupplySecondsOnBattery2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Same as arrisMtaDevPwrSupplySecondsOnBattery but for 2nd battery."
|
|
::= { arrisMtaDevPwrSupplyStats 12 }
|
|
|
|
arrisMtaDevPwrSupplyBatRatedMinutes2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Same as arrisMtaDevPwrSupplyBatRatedMinutes but for 2nd battery."
|
|
::= { arrisMtaDevPwrSupplyStats 13 }
|
|
|
|
arrisMtaDevPwrSupplyBatAvailableMinutes2 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Same as arrisMtaDevPwrSupplyBatAvailableMinutes but for 2nd battery."
|
|
::= { arrisMtaDevPwrSupplyStats 14 }
|
|
|
|
arrisMtaDevPwrSupplyTelemetryValues OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Power Supply Telemetry Values. Fields are delimited by semicolons."
|
|
::= { arrisMtaDevPwrSupplyStats 15 }
|
|
|
|
|
|
ac-Fail OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 1 }
|
|
|
|
chargerOverTemp-Shutdown OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 2 }
|
|
|
|
chargerTemperature-High OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 3 }
|
|
|
|
batteryCharger-Disabled OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 4 }
|
|
|
|
chargerDownload-Failed OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 5 }
|
|
|
|
battery-Mismatch OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 6 }
|
|
|
|
upsAlarmBatteryBad OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 7 }
|
|
|
|
upsAlarmLowBattery OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 8 }
|
|
|
|
upsAlarmDepletedBattery OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 9 }
|
|
|
|
upsAlarmUpsOutputOff OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 10 }
|
|
|
|
upsAlarmOutputOffAsRequested OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 11 }
|
|
|
|
upsAlarmGeneralFault OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 12 }
|
|
|
|
upsAlarmShutdownImminent OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 13 }
|
|
|
|
upsAlarmBatteryMissing OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 14 }
|
|
|
|
upsAlarmAwaitingPower OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 15 }
|
|
|
|
upsAlarmShutdownPending OBJECT IDENTIFIER ::= { arrisMtaDevPwrSupplyAlarm 16 }
|
|
|
|
|
|
arrisMtaDevBatteryStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF ArrisMtaDevBatteryStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Power Supply Telemetry table ...There will be one row in this
|
|
table for each battery pack in the device"
|
|
::= { arrisMtaDevPwrSupplyStats 3 }
|
|
|
|
arrisMtaDevBatteryStatusEntry OBJECT-TYPE
|
|
SYNTAX ArrisMtaDevBatteryStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status information for a single battery pack. An entry in this
|
|
table exists for each battery pack contained in the device."
|
|
INDEX { arrisMtaDevBatteryStatusIndex }
|
|
::= { arrisMtaDevBatteryStatusTable 1 }
|
|
|
|
ArrisMtaDevBatteryStatusEntry ::= SEQUENCE {
|
|
arrisMtaDevBatteryStatusIndex INTEGER,
|
|
arrisMtaDevBatteryOperState INTEGER,
|
|
arrisMtaDevBatteryLastStateChange TimeStamp,
|
|
arrisMtaDevBatteryOperSubState SnmpAdminString,
|
|
arrisMtaDevBatteryOrderingCode SnmpAdminString,
|
|
arrisMtaDevBatteryEprom SnmpAdminString
|
|
}
|
|
|
|
arrisMtaDevBatteryStatusIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index value that uniquely identifies each battery pack
|
|
in the MTA device. The table index ...."
|
|
::= { arrisMtaDevBatteryStatusEntry 1 }
|
|
|
|
arrisMtaDevBatteryOperState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unavailable(0),
|
|
invalid(1),
|
|
shutdownWarning(2),
|
|
batteryReversedShorted(3),
|
|
batteryLow-replaceBattery-acFail(4),
|
|
batteryLow-replaceBattery(5),
|
|
batteryLow-acFail(6),
|
|
batteryLow(7),
|
|
batteryMissing(8),
|
|
acFail-replaceBattery(9),
|
|
replaceBattery(10),
|
|
acFail(11),
|
|
normal(12),
|
|
testInProgress(13),
|
|
chargerFailure(14)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current operational state of the battery."
|
|
::= { arrisMtaDevBatteryStatusEntry 2 }
|
|
|
|
arrisMtaDevBatteryLastStateChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the battery entered its
|
|
current operational state. If the current state was entered
|
|
prior to the last re-initialization of the local network management
|
|
subsystem, then this object contains a zero value."
|
|
::= { arrisMtaDevBatteryStatusEntry 3 }
|
|
|
|
arrisMtaDevBatteryOperSubState OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current sub-state of the battery. This info
|
|
is not designed to match the arrisMtaDevBatteryOperState but to
|
|
provide additional information as to the UPS Status."
|
|
::= { arrisMtaDevBatteryStatusEntry 4 }
|
|
|
|
arrisMtaDevBatteryOrderingCode OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Arris ordering code for the battery(s) currently installed."
|
|
::= { arrisMtaDevBatteryStatusEntry 5 }
|
|
|
|
arrisMtaDevBatteryEprom OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Battery EPROM information for the battery(s) currently installed."
|
|
::= { arrisMtaDevBatteryStatusEntry 6 }
|
|
|
|
arrisMtaDevPwrSupplyEnableDataShutdown OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION ""
|
|
DEFVAL { disabled }
|
|
::= { arrisMtaDevPwrSupplyControl 1 }
|
|
arrisMtaDevPwrSupplyEnableWifiShutdown OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0),
|
|
enabled(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This MIB allows WTMx52 modems to shut down its wireless signal for power saving when modem switches to battery power.
|
|
If set this MIB to true, when AC fail and MTA is on Battery power, after about a timeout(specified by arrisMtaDevPwrSupplyDataShutdownTime), wifi signal would be turned off to save power and restored when AC power is on again.
|
|
Note: This MIB only takes affect when arrisMtaDevPwrSupplyEnableDataShutdown is set to disable."
|
|
DEFVAL { disabled }
|
|
::= { arrisMtaDevPwrSupplyControl 2 }
|
|
arrisMtaDevPwrSupplyLowBatteryThresh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the low battery threshold, which is used to detect a low battery condition.
|
|
The variable is expressed in 10 watt*minutes/count. The initial default value
|
|
is equivalent to 1 hour of holdup time. (Only available on MODEL 5 and MODEL 6 modems. Not supported on TM508/512)"
|
|
::= { arrisMtaDevPwrSupplyControl 3 }
|
|
|
|
arrisMtaDevPwrSupplyTypicalIdlePwr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The typical Idle power expressed in 50 mw/count. A typical value is
|
|
loaded upon power up. It is used in conjunction with the Tested Battery Capacity,
|
|
Low Battery Threshold and the Replace Battery Threshold to determine when to
|
|
raise Replace Battery Alarm or the Low Battery Alarm. (Only available on MODEL 5 and MODEL 6 modems. Not supported on TM508/512)"
|
|
::= { arrisMtaDevPwrSupplyControl 4 }
|
|
|
|
arrisMtaDevPwrSupplyReplaceBatThresh OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sets the minimum acceptable battery charge needed to achieve the desired End of
|
|
Life holdup time based on typical Idle Power. If the Tested Battery Capacity
|
|
minus the Charge Hysteresis loss (20%) is less than this value, the Replace
|
|
Battery alarm will be raised. The variable is expressed in 10 watt*minutes/count.
|
|
The initial default value provides 1 hour of holdup time. (Only available on MODEL 5 and MODEL 6 modems. Not supported on TM508/512)"
|
|
::= { arrisMtaDevPwrSupplyControl 5 }
|
|
|
|
arrisMtaDevPwrSupplyChargeState OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Causes the battery to be charged to the level that is specified by the data.
|
|
The value of charge is expressed in 10 watt*minutes/count. In order for the
|
|
battery to be charged to the correct level, issuing this command will cause
|
|
the charger to enter a discharge/charge cycle. The initial default value for
|
|
this parameter is 0.8 times the Rated Battery Capacity. This command should
|
|
be used with discretion. (Only available on MODEL 5 and MODEL 6 modems. Not supported on TM508/512)"
|
|
::= { arrisMtaDevPwrSupplyControl 6 }
|
|
|
|
|
|
arrisMtaDevPwrSupplyBatteryTest OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
testScheduled(0),
|
|
disableAutoTesting(1),
|
|
testInProgress(2),
|
|
testPending(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB cannot be set on TM402 devices.
|
|
|
|
This feature controls the scheduling of the battery test.
|
|
|
|
TestScheduled: When written, causes the battery test scheduler to resume at its
|
|
current value. When read, means that the battery test will run when the scheduled
|
|
time expires.
|
|
|
|
DisableAutoTesting: When written, freezes the battery test scheduler at its
|
|
current value. When read, means that the battery test will never run - with one
|
|
exception. If a battery is removed and replaced, the test will run immediately.
|
|
Once the test completes, the pause status will still be in effect. Therefore,
|
|
the battery test will not run a second time.
|
|
|
|
TestInProgress: When written, causes the battery test cycle to start immediately
|
|
and the test scheduler to be reset to its default value of 180 days. This command
|
|
is ignored if there is a test in progress. When read, means test in progress.
|
|
|
|
TestPending: If a battery test is in progress and either: AC power is lost; or a
|
|
full charge is requested - the battery test is paused and the status is reported
|
|
as pending. This is a read-only value."
|
|
::= { arrisMtaDevPwrSupplyControl 8 }
|
|
|
|
|
|
|
|
arrisMtaDevPwrSupplyConfigRunTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An estimate of the available run-time on the battery based upon the unit's
|
|
typical idle power and the programmed battery charge setting. The available
|
|
battery back up time may be adjusted using this value. By programming the
|
|
run-time to a lower value, the total service life of the battery is extended.
|
|
Increasing the run-time in turn decreases the total service life of the battery.
|
|
Setting this value greater than arrisMtaDevPwrSupplyBatAvailableMinutes will not
|
|
provide a run-time greater than arrisMtaDevPwrSupplyBatAvailableMinutes. This
|
|
value can only be set to multiples of 5 minutes."
|
|
::= { arrisMtaDevPwrSupplyControl 9 }
|
|
|
|
|
|
|
|
arrisMtaDevPwrSupplyConfigReplaceBatTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines the replace battery threshold in terms of run-time minutes. If a battery's
|
|
capacity has degraded to a point where it can no longer provide more than x minutes of
|
|
run-time, the Replace Battery condition becomes active. The default value at power up
|
|
is 60 minutes. This value can only be set to multiples of 5 minutes."
|
|
::= { arrisMtaDevPwrSupplyControl 10 }
|
|
|
|
|
|
|
|
arrisMtaDevPwrSupplyConfigReplaceBatTime2 OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "minutes"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Same as arrisMtaDevPwrSupplyConfigReplaceBatTime but for 2nd battery."
|
|
::= { arrisMtaDevPwrSupplyControl 11 }
|
|
|
|
|
|
|
|
arrisMtaDevPwrSupplyOverTempAlarmControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1),
|
|
pendingenable(2),
|
|
pendingdisable(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether an Over Temperature Alarm is issued when the temperature
|
|
specified in arrisMtaDevPwrSupplyOverTempAlarmThreshold is reached. Also
|
|
determines whether the battery charger shuts down upon reaching 90C.
|
|
|
|
For 602 devices and above, this is always Enabled and cannot be set to Disabled.
|
|
For 502/552/504 devices, this is settable to Enabled and Disabled."
|
|
::= { arrisMtaDevPwrSupplyControl 12 }
|
|
|
|
|
|
|
|
arrisMtaDevPwrSupplyOverTempAlarmThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "degrees-C"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines temperature threshold for Over Temperature Alarm. Minimum
|
|
temperature is 50C. Maximum is 70C."
|
|
::= { arrisMtaDevPwrSupplyControl 13 }
|
|
|
|
|
|
|
|
arrisMtaDevPwrSupplyTemperature OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current temperature in degrees C. This is only available
|
|
when arrisMtaDevPwrSupplyOverTempAlarmControl is enabled."
|
|
::= { arrisMtaDevPwrSupplyControl 14 }
|
|
|
|
arrisMtaDevPwrSupplyHiTempBatteryShutdownControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(0),
|
|
enable(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Determines whether the battery will be turned off when the temperature
|
|
reaches 75C and above."
|
|
::= { arrisMtaDevPwrSupplyControl 15 }
|
|
|
|
arrisMtaDevPwrSupplyHighestTemperature OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The highest recorded battery charger temperature in degrees C. This is only available
|
|
when arrisMtaDevPwrSupplyOverTempAlarmControl is enabled."
|
|
::= { arrisMtaDevPwrSupplyControl 16 }
|
|
|
|
arrisMtaDevPwrSupplyHighestTemperatureTime OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Displays the time and date when the highest temperature was recorded."
|
|
::= { arrisMtaDevPwrSupplyControl 17 }
|
|
|
|
arrisMtaDevPwrSupplyHighestTemperatureClear OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clear(1)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this MIB Clears arrisMtaDevPwrSupplyHighestTemperature and
|
|
arrisMtaDevPwrSupplyHighestTemperatureTime. These MIBs will be assigned
|
|
new values in a maximum of 4 seconds when the current temperature is calculated."
|
|
::= { arrisMtaDevPwrSupplyControl 18 }
|
|
|
|
arrisMtaDevPwrSupplyControlChargerReset OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This MIB object will reset the battery charger when set to true(1).
|
|
Warning: Resetting the battery charger in an AC Fail condition will immediately
|
|
shutdown the unit. This MIB object will always return false(2) when read."
|
|
::= { arrisMtaDevPwrSupplyControl 19 }
|
|
|
|
arrisMtaDevPwrSupplyDataShutdownTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the timeout period, in seconds, that the device will terminate
|
|
data services. The timer will start upon loss of AC power and operation
|
|
of battery backup begins. After the timer expires, the device will stop
|
|
providing data services (Ethernet and USB) and shutdown those functions
|
|
to conserve battery capacity. The default value for this object is 15
|
|
minutes(900 seconds) on model7 units, 5 minutes(300 seconds) on 16xx units
|
|
that support 802.11n(1642/62/72), and 1682 and 24xx units which support 802.11ac."
|
|
::= { arrisMtaDevPwrSupplyTimers 1 }
|
|
|
|
|
|
arrisMtaDevPwrSupplyFullChargeTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Causes the battery to be charged to 100% of its rated voltage and be maintained
|
|
at that level according the number of days set by the data. After the time has
|
|
elapsed, the battery charge level will be returned to the value specified by
|
|
arrisMtaDevPwrSupplyChargeState. Range of reported values: 0-16 days.
|
|
Values that can be written range from 1-16 days. If 1 is written the full charge
|
|
level will be maintained for 1 day. After that the full charge state will be
|
|
aborted and the battery charge will return to the set charge level or a test
|
|
will resume if one is pending. (This MIB is only effective on TM5xx and TM6xx HW models)"
|
|
::= { arrisMtaDevPwrSupplyTimers 2 }
|
|
|
|
|
|
|
|
|
|
END
|