Observium_CE/mibs/alvarion/RAINBOW-PERFORMANCE-MIB

1745 lines
58 KiB
Plaintext

--
--
-- Rainbow Performance Management Information Base
--
-- 06/06/2006
--
--
RAINBOW-PERFORMANCE-MIB DEFINITIONS ::= BEGIN
IMPORTS
rainbow, Modulation
FROM RAINBOW-MIB
rbServiceID
FROM RAINBOW-SERVICES-MIB
MODULE-IDENTITY, OBJECT-TYPE, Counter32, Unsigned32, Gauge32, Integer32
FROM SNMPv2-SMI
DisplayString, MacAddress
FROM SNMPv2-TC
ifIndex
FROM RFC1213-MIB;
-- enterprises OBJECT IDENTIFIER ::=
-- { iso org(3) dod(6) internet(1) private(4) 1 }
-- alvarion OBJECT IDENTIFIER ::= { enterprises 12394 }
-- products OBJECT IDENTIFIER ::= { alvarion 1 }
-- rainbow OBJECT IDENTIFIER ::= { products 2 }
rbPerformance MODULE-IDENTITY
LAST-UPDATED "200606061500Z"
ORGANIZATION "Alvarion Ltd."
CONTACT-INFO "Alvarion Customer Service
Postal: Alvarion Ltd.
Barzel 21
Tel Aviv 69710
ISRAEL
E-mail: CS_Coordinator@alvarion.com"
DESCRIPTION
"Rainbow Performance monitoring MIB Definitions"
REVISION "200606061500Z"
DESCRIPTION
"Revision 2.5"
::= { rainbow 4 }
-- ####################################################################
-- Service Specific Performance Indicators
-- ####################################################################
rbPMServ OBJECT IDENTIFIER ::= { rbPerformance 1 }
-- #######################################################################
-- Performance Indicators of Connection Table for CG (VoIP) Services
-- #######################################################################
rbPMCGServConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbPMCGServConnEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"This table is deprecated from NPU version 1.5
This table contains cumulative parameters per each CG (VoIP) Service
defined for the system.
All Statistics counters are accumulated since last reset "
::= { rbPMServ 1 }
rbPMCGServConnEntry OBJECT-TYPE
SYNTAX RbPMCGServConnEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Entry in the rbPMCGServConnTable "
INDEX { rbServiceID , rbPMCGConnDirection }
::= { rbPMCGServConnTable 1 }
RbPMCGServConnEntry ::= SEQUENCE {
rbPMCGConnDirection INTEGER,
rbPMCGConnByteReq Counter32,
rbPMCGConnByteTx Counter32,
rbPMCGConnByteRetTx Counter32,
rbPMCGConnByteDropped Counter32,
rbPMCGConnByteDiscarded Counter32,
rbPMCGConnPktsReq Counter32,
rbPMCGConnPktsTx Counter32,
rbPMCGConnPktsDropped Counter32,
rbPMCGConnPktsDiscarded Counter32,
rbPMCGConnAvarageDelay Integer32,
rbPMCGConnStandardDeviationDelay Integer32,
rbPMCGConnMaxDelay Integer32,
rbPMCGConnPerSucsGrant Counter32,
rbPMCGConnAvgGrantInt Counter32,
rbPMCGConnMaxGrantInt Counter32,
rbPMCGConnAvgIntArvTime Counter32,
rbPMCGConnMaxIntArvTime Counter32,
rbPMCGConnMinIntArvTime Counter32,
rbPMCGConnAvgSDUDropRate Counter32,
rbPMCGConnResetCounters Integer32
}
rbPMCGConnDirection OBJECT-TYPE
SYNTAX INTEGER
{
downLink (1),
upLink (2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The direction in which counters were measured . "
::= { rbPMCGServConnEntry 1 }
rbPMCGConnByteReq OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of bytes submitted by upper layers to this connection"
::= { rbPMCGServConnEntry 2 }
rbPMCGConnByteTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of bytes transmitted to WL port through this
connection including retransmissions."
::= { rbPMCGServConnEntry 3 }
rbPMCGConnByteRetTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of bytes retransmitted to WL port through this connection."
::= { rbPMCGServConnEntry 4 }
rbPMCGConnByteDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of bytes dropped from this connection."
::= { rbPMCGServConnEntry 5 }
rbPMCGConnByteDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of bytes discarded from this connection"
::= { rbPMCGServConnEntry 6 }
rbPMCGConnPktsReq OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of packets submitted by upper layers to this connection"
::= { rbPMCGServConnEntry 7 }
rbPMCGConnPktsTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of packets transmitted to WL through this connection
not including retransmissions."
::= { rbPMCGServConnEntry 8 }
rbPMCGConnPktsDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of packets dropped by the transmitter for this connection"
::= { rbPMCGServConnEntry 9 }
rbPMCGConnPktsDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of packets discarded by the transmitter for this connection."
::= { rbPMCGServConnEntry 10 }
rbPMCGConnAvarageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Average packet delay in milliseconds, measured for this connection over the last 15 seconds."
::= { rbPMCGServConnEntry 11 }
rbPMCGConnStandardDeviationDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The variance of the packet delay, in milliseconds~2,
measured for this connection over the last 15 seconds."
::= { rbPMCGServConnEntry 12 }
rbPMCGConnMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The maximum packet delay in milliseconds,
measured for this connection over the last 15 seconds."
::= { rbPMCGServConnEntry 13 }
rbPMCGConnPerSucsGrant OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Percentage of successes in granting the transmission,
measured for this Continuing Grant CONN over the last 15 seconds."
::= { rbPMCGServConnEntry 14 }
rbPMCGConnAvgGrantInt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Average Grant Interval, in microseconds,
measured for this Continuing Grant CONN over the last 15 seconds."
::= { rbPMCGServConnEntry 15 }
rbPMCGConnMaxGrantInt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Maximum Grant Interval, in microseconds,
measured for this Continuing Grant CONN over the last 15 seconds."
::= { rbPMCGServConnEntry 16 }
rbPMCGConnAvgIntArvTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Average of the SDU Inter-Arrival Time Interval measured
for this Continuing Grant CONN in the last 15 seconds."
::= { rbPMCGServConnEntry 17 }
rbPMCGConnMaxIntArvTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Maximum of the SDU Inter-Arrival Time Interval,
in microseconds, measured for this Continuing Grant CONN over the last 15 seconds."
::= { rbPMCGServConnEntry 18 }
rbPMCGConnMinIntArvTime OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Minimum of the SDU Inter-Arrival Time Interval,
in microseconds, measured for this Continuing Grant CONN over the last 15 seconds."
::= { rbPMCGServConnEntry 19 }
rbPMCGConnAvgSDUDropRate OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of packets dropped per second for this connection, averaged over the last 15 seconds."
::= { rbPMCGServConnEntry 20 }
rbPMCGConnResetCounters OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"Resets the connection counters in this table entry"
::= { rbPMCGServConnEntry 21 }
-- ###############################################################################
-- Per Connection Service Performance Indicators
-- ###############################################################################
rbPMServConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbPMServConnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains performance indication parameters per each connection
in the currently active services. All Statistics counters for BE, RT and NRT connections
are accumulated since last reset. Counters for active CG connections
are accumulated from session start time."
::= { rbPMServ 2 }
rbPMServConnEntry OBJECT-TYPE
SYNTAX RbPMServConnEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the rbPMServConnTable "
INDEX {rbServiceID, rbPMConnDirection, rbPMConnQoSPipeIdx}
::= { rbPMServConnTable 1 }
RbPMServConnEntry ::= SEQUENCE {
rbPMConnDirection INTEGER,
rbPMConnQoSPipeIdx Integer32,
rbPMConnByteReq Counter32,
rbPMConnByteTx Counter32,
rbPMConnByteRetTx Counter32,
rbPMConnByteDropped Counter32,
rbPMConnByteDiscarded Counter32,
rbPMConnPktsReq Counter32,
rbPMConnPktsTx Counter32,
rbPMConnPktsDropped Counter32,
rbPMConnPktsDiscarded Counter32,
rbPMConnAvarageDelay Integer32,
rbPMConnStandardDeviationDelay Integer32,
rbPMConnMaxDelay Integer32,
rbPMConnCBP Gauge32,
rbPMConnDLI Gauge32,
rbPMConnExBurst Gauge32,
rbPMConnAvgThroughput Gauge32,
rbPMConnResetCounters INTEGER,
rbPMConnServiceIdx Unsigned32,
rbPMConnQoSType INTEGER,
rbPMConnQosParam1 Unsigned32,
rbPMConnQosParam2 Unsigned32,
rbPMConnQosParamTime INTEGER
}
rbPMConnDirection OBJECT-TYPE
SYNTAX INTEGER
{
downLink (1),
upLink (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of the connection."
::= { rbPMServConnEntry 1 }
rbPMConnQoSPipeIdx OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 4 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the connection (up to 4) established for the Service."
::= { rbPMServConnEntry 2 }
rbPMConnByteReq OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes submitted by upper layers to this connection."
::= { rbPMServConnEntry 3 }
rbPMConnByteTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes transmitted to the wireless port through this connection,
including retransmissions."
::= { rbPMServConnEntry 4 }
rbPMConnByteRetTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes retransmitted to the wireless port through this connection."
::= { rbPMServConnEntry 5 }
rbPMConnByteDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes dropped from this connection due to congestion in the wireless link.
Identical to rbPMConnByteDiscarded."
::= { rbPMServConnEntry 6 }
rbPMConnByteDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of bytes discarded from this connection due to congestion in the wireless link.
Identical to rbPMConnByteDropped."
::= { rbPMServConnEntry 7 }
rbPMConnPktsReq OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets submitted by upper layers to this connection."
::= { rbPMServConnEntry 8 }
rbPMConnPktsTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets transmitted to the wireless port through this connection
not including retransmissions."
::= { rbPMServConnEntry 9 }
rbPMConnPktsDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets dropped by the transmitter for this connection due to
congestion in the wireless link. Identical to rbPMConnPktsDiscarded."
::= { rbPMServConnEntry 10 }
rbPMConnPktsDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of packets discarded by the transmitter for this connection due to
congestion in the wireless link. Identical to rbPMConnPktsDropped."
::= { rbPMServConnEntry 11 }
rbPMConnAvarageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Average packet delay in milliseconds, measured for this connection
over the last 15 seconds. The value is updated every 15 seconds."
::= { rbPMServConnEntry 12 }
rbPMConnStandardDeviationDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The variance (the standard deviation squared) of the packet delay,
in milliseconds square, measured for this connection over the last 15 seconds.
The value is updated every 15 seconds."
::= { rbPMServConnEntry 13 }
rbPMConnMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum packet delay in milliseconds, measured for this connection
over the last 15 seconds. The value is updated every 15 seconds."
::= { rbPMServConnEntry 14 }
rbPMConnCBP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The CIR utilization measured for an RT or NRT connection over the last 15 seconds.
Not applicable for BE and CG connections.
k = 100 x (the minimum between bytes transferred and CIR)/CIR is calculated for each
1 second interval. CIR Utilization equals the average of k over the last 15 seconds,
and may vary from 0 to 100. The value is updated every 15 seconds."
::= { rbPMServConnEntry 15 }
rbPMConnDLI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The percentage of dropped packets, out of the total demand,
measured for this connection over the last 15 seconds.
DLI (%) = 100*(Packets Dropped)/(Packets Submitted).
The value is updated every 15 seconds."
::= { rbPMServConnEntry 16 }
rbPMConnExBurst OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Excess Information Rate utilization measured for a BE or NRT connection over the last 15 seconds.
Not applicable for RT and CG connections.
k=100 x (bytes transferred-CIR)/(MIR-CIR) is calculated for each 1 second interval.
In BE CIR = 0. The EIR Utilization equals the average of k over the last 15 seconds,
and may range from 0 to 100. The value is updated every 15 seconds."
::= { rbPMServConnEntry 17 }
rbPMConnAvgThroughput OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average throughput, in bits/second, measured for this connection
for the last 15 seconds. The value is updated every 15 seconds."
::= { rbPMServConnEntry 18 }
rbPMConnResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to reset (1), the Service counters will be initialized to 0.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbPMServConnEntry 19 }
rbPMConnServiceIdx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the relevant Service Entry."
::= { rbPMServConnEntry 20 }
rbPMConnQoSType OBJECT-TYPE
SYNTAX INTEGER { rbCG (1), rbRT ( 2 ) , rbNRT ( 3 ) , rbBE ( 4 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The QoS Type used in the connection."
::= { rbPMServConnEntry 21 }
rbPMConnQosParam1 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of rbQoSProfileParam1 of the QoS Profile used in the connection.
For RT and NRT connections, this parameter is the CIR (Kbps).
For CG connections this is the Packet Size (bytes).
For BE connection this parameter is not applicable."
::= { rbPMServConnEntry 22 }
rbPMConnQosParam2 OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of rbQoSProfileParam2 of the QoS Profile used in the connection.
For BE and NRT connections, this parameter is the MIR (Kbps).
For CG connections this is the Sample Interval (milliseconds).
For RT connections this parameter is not applicable."
::= { rbPMServConnEntry 23 }
rbPMConnQosParamTime OBJECT-TYPE
SYNTAX INTEGER { short ( 1 ) , medium ( 2 ) , long ( 3 ) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of rbQoSProfileParamTime of the QoS Profile used in the connection.
This is the CT (Committed Time) parameter that defines the time window over
which the information rate is averaged to ensure compliance with
the CIR and/or MIR parameter for BE, NRT and RT connections.
For CG connections this parameter is not applicable."
::= { rbPMServConnEntry 24 }
-- ####################################################################################
-- Packet Error Rate Counters
-- PER counters are collected per SU and are retrieved using community SU.<MAC Address>
-- ####################################################################################
rbPMPacketErrorRateTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbPMPacketErrorRateEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Deprecated. A table that contains Packet Error Rate (PER) Counters"
::= { rbPerformance 4 }
rbPMPacketErrorRateEntry OBJECT-TYPE
SYNTAX RbPMPacketErrorRateEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Entry in the Packet Error Rate Table."
INDEX {rbPMDirection }
::= { rbPMPacketErrorRateTable 1 }
RbPMPacketErrorRateEntry ::= SEQUENCE {
rbPMDirection INTEGER,
rbPMTotalBursts Counter32,
rbPMErrorBursts Counter32,
rbPMResetCounters INTEGER
}
rbPMDirection OBJECT-TYPE
SYNTAX INTEGER
{
downLink (1),
upLink (2)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The direction in which counters were measured."
::= { rbPMPacketErrorRateEntry 1 }
rbPMTotalBursts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of bursts received by SU since the last reset of counters."
::= { rbPMPacketErrorRateEntry 2 }
rbPMErrorBursts OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The total number of error bursts received by SU since the last reset of counters."
::= { rbPMPacketErrorRateEntry 3 }
rbPMResetCounters OBJECT-TYPE
SYNTAX INTEGER {
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"When Set to reset (1) PER Modulation Table counters are reset to 0."
::= { rbPMPacketErrorRateEntry 4 }
-- ####################################################################################
-- Reset ifTable Counters
-- For AU - <community>@AU.<Slot Number> is used.
-- For SU - <community>@SU.<MAC Address> is used
-- ####################################################################################
rbPMIfCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbPMIfCountersEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Deprecated from version 2.1. A table of interface Counters.
It is recommended to use the rbPMIfCounters (rbNPUDataPortCounters, rbManagementPortCounters,
rbSUEthernetCounters, rbSUWirelessCounters, rbAUBackplaneCounters, rbAUWirelessCounters)
rather than these counters."
::= { rbPerformance 5 }
rbPMIfCountersEntry OBJECT-TYPE
SYNTAX RbPMIfCountersEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Entry in the rbPMIfCountersTable."
INDEX { ifIndex }
::= { rbPMIfCountersTable 1 }
RbPMIfCountersEntry ::= SEQUENCE {
rbPMIfInResetCounters INTEGER,
rbPMIfInForwardedBytes Counter32,
rbPMIfInInternalBytes Counter32,
rbPMIfInDiscardedBytes Counter32,
rbPMIfOutInternalPackets Counter32,
rbPMIfOutResetCounters INTEGER,
rbPMIfOutSubmittedBytes Counter32,
rbPMIfOutInternalBytes Counter32,
rbPMIfOutDiscardedBytes Counter32
}
rbPMIfInResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"When set to reset (1), In counters of the specified interface on the specified
device will be initialised to 0."
::= { rbPMIfCountersEntry 1 }
rbPMIfInForwardedBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of bytes submitted to interface."
::= { rbPMIfCountersEntry 2 }
rbPMIfInInternalBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of bytes submitted to Internal Port."
::= { rbPMIfCountersEntry 3 }
rbPMIfInDiscardedBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of bytes discarded when received from the interface."
::= { rbPMIfCountersEntry 4 }
rbPMIfOutInternalPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of packets, created internally by device and transmitted through the
wireless interface. Value 0 should be returned for the Ethernet Interface."
::= { rbPMIfCountersEntry 5 }
rbPMIfOutResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"When set to reset (1), Out counters of the specified interface on the specified
device will be initialised to 0."
::= { rbPMIfCountersEntry 6 }
rbPMIfOutSubmittedBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of bytes submitted from intetface."
::= { rbPMIfCountersEntry 7 }
rbPMIfOutInternalBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of bytes submitted from Internal Port."
::= { rbPMIfCountersEntry 8 }
rbPMIfOutDiscardedBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"Number of bytes discarded during the transmit through the interface."
::= { rbPMIfCountersEntry 9 }
-- ####################################################################################
-- Burst Error Rate Counters
-- ####################################################################################
rbPMBurstErrRateCounters OBJECT IDENTIFIER
::= { rbPerformance 6 }
rbPMBurstErrorRateTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbPMBurstErrorRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table that contains Burst Error Rate (BER) Counters for each Rate
in the Uplink and Downlink of each SU."
::= { rbPMBurstErrRateCounters 1 }
rbPMBurstErrorRateEntry OBJECT-TYPE
SYNTAX RbPMBurstErrorRateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the Burst Error Rate Table."
INDEX {rbPMBurstSuMacAddr, rbPMBurstDirection, rbPMBurstRate}
::= { rbPMBurstErrorRateTable 1 }
RbPMBurstErrorRateEntry ::= SEQUENCE {
rbPMBurstSuMacAddr MacAddress,
rbPMBurstDirection INTEGER,
rbPMBurstRate Modulation,
rbPMBurstCountersReset INTEGER,
rbPMBurstTotal Counter32,
rbPMBurstError Counter32,
rbPMBurstErrorRate DisplayString
}
rbPMBurstSuMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC Address of SU."
::= { rbPMBurstErrorRateEntry 1 }
rbPMBurstDirection OBJECT-TYPE
SYNTAX INTEGER
{
downLink (1),
upLink (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction in which counters were measured."
::= { rbPMBurstErrorRateEntry 2 }
rbPMBurstRate OBJECT-TYPE
SYNTAX Modulation
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Modulation and Coding Rate of the entry."
DEFVAL { 1 }
::= { rbPMBurstErrorRateEntry 3 }
rbPMBurstCountersReset OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset the BER Counters for the selected SU, for all rates in the relevant direction.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbPMBurstErrorRateEntry 4 }
rbPMBurstTotal OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Bursts transmitted to/from the SU at the relevant rate and direction."
::= { rbPMBurstErrorRateEntry 5 }
rbPMBurstError OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Error Bursts at the relevant rate and direction."
::= { rbPMBurstErrorRateEntry 6 }
rbPMBurstErrorRate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Burst Error Rate for the relevant rate and direction (100*Burst Error/Burst Total)."
::= { rbPMBurstErrorRateEntry 7 }
-- ####################################################################################
-- ifTable Counters
-- For NPU .
-- For AU .
-- For SU .
-- ####################################################################################
rbPMIfCounters OBJECT IDENTIFIER
::= { rbPerformance 7 }
rbNPUDataPortCounters OBJECT IDENTIFIER
::= { rbPMIfCounters 1 }
rbMBSTDataPortCounters OBJECT IDENTIFIER
::= { rbPMIfCounters 2 }
rbManagementPortCounters OBJECT IDENTIFIER
::= { rbPMIfCounters 10 }
rbSUEthernetCounters OBJECT IDENTIFIER
::= { rbPMIfCounters 20 }
rbSUWirelessCounters OBJECT IDENTIFIER
::= { rbPMIfCounters 21 }
rbAUBackplaneCounters OBJECT IDENTIFIER
::= { rbPMIfCounters 30 }
rbAUWirelessCounters OBJECT IDENTIFIER
::= { rbPMIfCounters 31 }
-- ####################################################################################
rbNPUDataPortCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbNPUDataPortCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of NPU Data port counters."
::= { rbNPUDataPortCounters 1 }
rbNPUDataPortCountersEntry OBJECT-TYPE
SYNTAX RbNPUDataPortCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the rbNPUDataPortCountersTable."
INDEX { rbPMIfSlot }
::= { rbNPUDataPortCountersTable 1 }
RbNPUDataPortCountersEntry ::= SEQUENCE {
rbPMIfSlot Integer32,
rbNpuDataPortResetCounters INTEGER,
rbNpuDataPortTotalPacketsRx Counter32,
rbNpuDataPortMangementPacketsFw Counter32,
rbNpuDataPortPacketsFwToSlot1 Counter32,
rbNpuDataPortPacketsFwToSlot2 Counter32,
rbNpuDataPortPacketsFwToSlot3 Counter32,
rbNpuDataPortPacketsFwToSlot4 Counter32,
rbNpuDataPortPacketsFwToSlot7 Counter32,
rbNpuDataPortPacketsFwToSlot8 Counter32,
rbNpuDataPortPacketsFwToSlot9 Counter32,
rbNpuDataPortPacketsDiscardedOnRx Counter32,
rbNpuDataPortTotalPacketsTx Counter32,
rbNpuDataPortMangementPacketsSbmt Counter32,
rbNpuDataPortPacketsSbmtFromSlot1 Counter32,
rbNpuDataPortPacketsSbmtFromSlot2 Counter32,
rbNpuDataPortPacketsSbmtFromSlot3 Counter32,
rbNpuDataPortPacketsSbmtFromSlot4 Counter32,
rbNpuDataPortPacketsSbmtFromSlot7 Counter32,
rbNpuDataPortPacketsSbmtFromSlot8 Counter32,
rbNpuDataPortPacketsSbmtFromSlot9 Counter32,
rbNpuDataPortPacketsDiscardedOnTx Counter32
}
rbPMIfSlot OBJECT-TYPE
SYNTAX Integer32 ( 5 .. 6 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The NPU's slot number: 5 or 6. In current version only 5 is applicable."
::= { rbNPUDataPortCountersEntry 1 }
rbNpuDataPortResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to reset (1), the Data port counters will be initialized to 0.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbNPUDataPortCountersEntry 2 }
rbNpuDataPortTotalPacketsRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received on the interface.
Packets with errors are not counted."
::= { rbNPUDataPortCountersEntry 3 }
rbNpuDataPortMangementPacketsFw OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of management packets
(packets whose destination is the NPU, and broadcasts)
received on the Data port and forwarded to the NPU's internal management."
::= { rbNPUDataPortCountersEntry 4 }
rbNpuDataPortPacketsFwToSlot1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received from the Data port and forwarded
by the NPU to AU Slot 1."
::= { rbNPUDataPortCountersEntry 5 }
rbNpuDataPortPacketsFwToSlot2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received from the Data port and forwarded
by the NPU to AU Slot 2."
::= { rbNPUDataPortCountersEntry 6 }
rbNpuDataPortPacketsFwToSlot3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received from the Data port and forwarded
by the NPU to AU Slot 3."
::= { rbNPUDataPortCountersEntry 7 }
rbNpuDataPortPacketsFwToSlot4 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received from the Data port and forwarded
by the NPU to AU Slot 4."
::= { rbNPUDataPortCountersEntry 8 }
rbNpuDataPortPacketsFwToSlot7 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received from the Data port and forwarded
by the NPU to AU Slot 7."
::= { rbNPUDataPortCountersEntry 9 }
rbNpuDataPortPacketsFwToSlot8 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received from the Data port and forwarded
by the NPU to AU Slot 8."
::= { rbNPUDataPortCountersEntry 10 }
rbNpuDataPortPacketsFwToSlot9 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received from the Data port and forwarded
by the NPU to AU Slot 9."
::= { rbNPUDataPortCountersEntry 11 }
rbNpuDataPortPacketsDiscardedOnRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received from the Data port that were discarded
due to switching and classification failures."
::= { rbNPUDataPortCountersEntry 12 }
rbNpuDataPortTotalPacketsTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted to the interface.
Packets with errors are not counted.."
::= { rbNPUDataPortCountersEntry 13 }
rbNpuDataPortMangementPacketsSbmt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of management packets submitted by the NPU to the Data port."
::= { rbNPUDataPortCountersEntry 14 }
rbNpuDataPortPacketsSbmtFromSlot1 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by the NPU from the AU in Slot 1
and submitted to the Data port."
::= { rbNPUDataPortCountersEntry 15 }
rbNpuDataPortPacketsSbmtFromSlot2 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by the NPU from the AU in Slot 2
and submitted to the Data port."
::= { rbNPUDataPortCountersEntry 16 }
rbNpuDataPortPacketsSbmtFromSlot3 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by the NPU from the AU in Slot 3
and submitted to the Data port."
::= { rbNPUDataPortCountersEntry 17 }
rbNpuDataPortPacketsSbmtFromSlot4 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by the NPU from the AU in Slot 4
and submitted to the Data port."
::= { rbNPUDataPortCountersEntry 18 }
rbNpuDataPortPacketsSbmtFromSlot7 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by the NPU from the AU in Slot 7
and submitted to the Data port."
::= { rbNPUDataPortCountersEntry 19 }
rbNpuDataPortPacketsSbmtFromSlot8 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by the NPU from the AU in Slot 8
and submitted to the Data port."
::= { rbNPUDataPortCountersEntry 20 }
rbNpuDataPortPacketsSbmtFromSlot9 OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by the NPU from the AU in Slot 9
and submitted to the Data port."
::= { rbNPUDataPortCountersEntry 21 }
rbNpuDataPortPacketsDiscardedOnTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Always 0. Currently packets are not discarded on Tx to the Data port."
::= { rbNPUDataPortCountersEntry 22 }
-- ####################################################################################
rbMBSTDataPortCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbMBSTDataPortCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of MBST Data port counters."
::= { rbMBSTDataPortCounters 1 }
rbMBSTDataPortCountersEntry OBJECT-TYPE
SYNTAX RbMBSTDataPortCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the rbMBSTDataPortCountersTable."
INDEX { rbMBSTDataPortIfSlot }
::= { rbMBSTDataPortCountersTable 1 }
RbMBSTDataPortCountersEntry ::= SEQUENCE {
rbMBSTDataPortIfSlot Integer32,
rbMBSTDataPortResetCounters INTEGER,
rbMBSTDataPortTotalBytesRx Counter32,
rbMBSTDataPortDataBytesRx Counter32,
rbMBSTDataPortDataBytesDiscardedOnRx Counter32,
rbMBSTDataPortTotalBytesTx Counter32,
rbMBSTDataPortDataBytesTx Counter32,
rbMBSTDataPortDataBytesDiscardedOnTx Counter32
}
rbMBSTDataPortIfSlot OBJECT-TYPE
SYNTAX Integer32 ( 1 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MBST Data Port Table index - always 1."
::= { rbMBSTDataPortCountersEntry 1 }
rbMBSTDataPortResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to reset (1), the Data port counters will be initialized to 0.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbMBSTDataPortCountersEntry 2 }
rbMBSTDataPortTotalBytesRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes received from the Data port, including Management frames.
Frames with errors are not included."
::= { rbMBSTDataPortCountersEntry 3 }
rbMBSTDataPortDataBytesRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes received from the Data port.
Management frames and frames with errors are not included."
::= { rbMBSTDataPortCountersEntry 4 }
rbMBSTDataPortDataBytesDiscardedOnRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes in data packets received from the Data port
that were discarded due to switching and classification failures."
::= { rbMBSTDataPortCountersEntry 5 }
rbMBSTDataPortTotalBytesTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes transmitted to the Data port, including Management frames.
Frames with errors are not included."
::= { rbMBSTDataPortCountersEntry 6 }
rbMBSTDataPortDataBytesTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes transmitted to the Data port.
Management frames and frames with errors are not included."
::= { rbMBSTDataPortCountersEntry 7 }
rbMBSTDataPortDataBytesDiscardedOnTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count is always 0 (No discards)."
::= { rbMBSTDataPortCountersEntry 8 }
-- ####################################################################################
rbMngmntPortCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbMngmntPortCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Management port counters."
::= { rbManagementPortCounters 1 }
rbMngmntPortCountersEntry OBJECT-TYPE
SYNTAX RbMngmntPortCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the rbMngmntPortCountersTable."
INDEX { rbMngmntPortIfSlot }
::= { rbMngmntPortCountersTable 1 }
RbMngmntPortCountersEntry ::= SEQUENCE {
rbMngmntPortResetCounters INTEGER,
rbMngmntPortPacketsRx Counter32,
rbMngmntPortPacketsDiscardedOnRx Counter32,
rbMngmntPortPacketsTx Counter32,
rbMngmntPortPacketsDiscardedOnTx Counter32,
rbMngmntPortIfSlot Integer32
}
rbMngmntPortResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to reset (1), the Management port counters will be initialized to 0.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbMngmntPortCountersEntry 1 }
rbMngmntPortPacketsRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received on the Management port.
Error packets are not counted."
::= { rbMngmntPortCountersEntry 2 }
rbMngmntPortPacketsDiscardedOnRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received on the Management port that were discarded."
::= { rbMngmntPortCountersEntry 3 }
rbMngmntPortPacketsTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted on the Management port.
Error packets are not counted."
::= { rbMngmntPortCountersEntry 4 }
rbMngmntPortPacketsDiscardedOnTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packet discarded on Tx on the Management port."
::= { rbMngmntPortCountersEntry 5 }
rbMngmntPortIfSlot OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 6 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For NPU - the NPU's slot number: 5 or 6. In current version only 5 is applicable.
For MBST - the MBST Management Port Table index (always 1)."
::= { rbMngmntPortCountersEntry 6 }
-- ####################################################################################
rbSUEthernetCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbSUEthernetCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of SU Ethernet port Counters"
::= { rbSUEthernetCounters 1 }
rbSUEthernetCountersEntry OBJECT-TYPE
SYNTAX RbSUEthernetCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the rbSUEthernetCountersTable."
INDEX { rbPMIfSuMacAddr }
::= { rbSUEthernetCountersTable 1 }
RbSUEthernetCountersEntry ::= SEQUENCE {
rbPMIfSuMacAddr MacAddress,
rbSUEthernetResetCounters INTEGER,
rbSUEthernetDataBytesRx Counter32,
rbSUEthernetDataBytesDiscardedOnRx Counter32,
rbSUEthernetDataBytesTx Counter32,
rbSUEthernetDataBytesDiscardedOnTx Counter32
}
rbPMIfSuMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MAC Address of SU."
::= { rbSUEthernetCountersEntry 1 }
rbSUEthernetResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to reset (1), the SU Ethernet port counters will be initialized to 0.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbSUEthernetCountersEntry 2 }
rbSUEthernetDataBytesRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes received on the Ethernet port,
excluding management frames and errors."
::= { rbSUEthernetCountersEntry 3 }
rbSUEthernetDataBytesDiscardedOnRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes discarded when a packet received
from the Ethernet is not forwarded to the Wireless port due to bridging
and classification considerations."
::= { rbSUEthernetCountersEntry 4 }
rbSUEthernetDataBytesTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes transmitted on the Ethernet port,
excluding management frames and errors."
::= { rbSUEthernetCountersEntry 5 }
rbSUEthernetDataBytesDiscardedOnTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes discarded when a packet received on
the Wireless port is not forwarded to the Ethernet due to bridging
and VLAN considerations."
::= { rbSUEthernetCountersEntry 6 }
-- ####################################################################################
rbSUWirelessCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbSUWirelessCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of SU Wireless port Counters."
::= { rbSUWirelessCounters 1 }
rbSUWirelessCountersEntry OBJECT-TYPE
SYNTAX RbSUWirelessCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the rbSUWirelessCountersTable."
INDEX { rbPMIfSuMacAddr }
::= { rbSUWirelessCountersTable 1 }
RbSUWirelessCountersEntry ::= SEQUENCE {
rbSUWirelessResetCounters INTEGER,
rbSUWirelessDataBytesRx Counter32,
rbSUWirelessDataBytesDiscardedOnRx Counter32,
rbSUWirelessDataBytesTx Counter32,
rbSUWirelessDataBytesDiscardedOnTx Counter32,
rbSUWirelessARQEnabledBytesTx Counter32,
rbSUWirelessRTxBytes Counter32,
rbSUWirelessRTxRate Gauge32
}
rbSUWirelessResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to reset (1), the SU Wireless port counters will be initialized to 0.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbSUWirelessCountersEntry 1 }
rbSUWirelessDataBytesRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes received on the Wireless port,
excluding management frames and errors."
::= { rbSUWirelessCountersEntry 2 }
rbSUWirelessDataBytesDiscardedOnRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes in packets discarded on Rx
on the Wireless port due to MAC protocol RX errors, such as
duplicate sequence number, wrong sequence number etc. (not CRC errors)."
::= { rbSUWirelessCountersEntry 3 }
rbSUWirelessDataBytesTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes transmitted on the Wireless port,
excluding MAC management frames and errors."
::= { rbSUWirelessCountersEntry 4 }
rbSUWirelessDataBytesDiscardedOnTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes in packets discarded on Tx
due to congestion in the wireless medium."
::= { rbSUWirelessCountersEntry 5 }
rbSUWirelessARQEnabledBytesTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes transmitted over BE and NRT connections.
Applicable only if the ARQ mechanism is enabled."
::= { rbSUWirelessCountersEntry 6 }
rbSUWirelessRTxBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of unacknowledged bytes that were retransmitted.
Retransmissions are applicable only to BE and NRT connections
provided the ARQ mechanism is enabled."
::= { rbSUWirelessCountersEntry 7 }
rbSUWirelessRTxRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Retransmission Rate in percents:
100*(Bytes Retransmitted)/(ARQ Enabled Bytes Transmitted)."
::= { rbSUWirelessCountersEntry 8 }
-- ####################################################################################
rbAUBackplaneCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbAUBackplaneCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of Backplane (NPU/AU connection) Counters."
::= { rbAUBackplaneCounters 1 }
rbAUBackplaneCountersEntry OBJECT-TYPE
SYNTAX RbAUBackplaneCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the rbAUBackplaneCountersTable."
INDEX { rbPMIfAUSlot }
::= { rbAUBackplaneCountersTable 1 }
RbAUBackplaneCountersEntry ::= SEQUENCE {
rbPMIfAUSlot Integer32,
rbAUBackplaneResetCounters INTEGER,
rbAUBackplaneDataBytesRx Counter32,
rbAUBackplaneDataBytesDiscardedOnRx Counter32,
rbAUBackplaneDataBytesTx Counter32,
rbAUBackplaneDataBytesDiscardedOnTx Counter32
}
rbPMIfAUSlot OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 9 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Physical placement of the card in the chassis (the Slot number 1-4, 7-9)."
::= { rbAUBackplaneCountersEntry 1 }
rbAUBackplaneResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to reset (1), the Back plane port counters will be initialized to 0.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbAUBackplaneCountersEntry 2 }
rbAUBackplaneDataBytesRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes received from the Back-panel (NPU),
excluding management frames and errors."
::= { rbAUBackplaneCountersEntry 3 }
rbAUBackplaneDataBytesDiscardedOnRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes in data packets discarded due to communication
errors between the AU and the NPU."
::= { rbAUBackplaneCountersEntry 4 }
rbAUBackplaneDataBytesTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes transmitted to the Back-panel (NPU),
excluding management frames and errors."
::= { rbAUBackplaneCountersEntry 5 }
rbAUBackplaneDataBytesDiscardedOnTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count is always 0 (No discards on Tx)."
::= { rbAUBackplaneCountersEntry 6 }
-- ####################################################################################
rbAUWirelessCountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF RbAUWirelessCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of AU Wireless port Counters."
::= { rbAUWirelessCounters 1 }
rbAUWirelessCountersEntry OBJECT-TYPE
SYNTAX RbAUWirelessCountersEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entry in the rbAUWirelessCountersTable."
INDEX { rbAUWirelessAUSlot }
::= { rbAUWirelessCountersTable 1 }
RbAUWirelessCountersEntry ::= SEQUENCE {
rbAUWirelessResetCounters INTEGER,
rbAUWirelessDataBytesRx Counter32,
rbAUWirelessDataBytesDiscardedOnRx Counter32,
rbAUWirelessDataBytesTx Counter32,
rbAUWirelessDataBytesDiscardedOnTx Counter32,
rbAUWirelessARQEnabledBytesTx Counter32,
rbAUWirelessRTxBytes Counter32,
rbAUWirelessRTxRate Gauge32,
rbAUWirelessAUSlot Integer32
}
rbAUWirelessResetCounters OBJECT-TYPE
SYNTAX INTEGER
{
noAction (0),
reset (1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to reset (1), the AU Wireless port counters will be initialized to 0.
noAction (0) value is available to support Get and Get Next commands.
It should not be used in Set commands."
::= { rbAUWirelessCountersEntry 1 }
rbAUWirelessDataBytesRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes received on the Wireless port,
excluding MAC management frames and errors."
::= { rbAUWirelessCountersEntry 2 }
rbAUWirelessDataBytesDiscardedOnRx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes in packets received on the Wireless link
and discarded due to MAC protocol receive errors, such as
duplicate sequence number, wrong sequence number etc. (not CRC errors)."
::= { rbAUWirelessCountersEntry 3 }
rbAUWirelessDataBytesTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of data bytes transmitted to the Wireless link,
excluding MAC Management frames and frames with errors."
::= { rbAUWirelessCountersEntry 4 }
rbAUWirelessDataBytesDiscardedOnTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes in packets discarded due to congestion in the wireless medium."
::= { rbAUWirelessCountersEntry 5 }
rbAUWirelessARQEnabledBytesTx OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of bytes transmitted over BE and NRT connections.
Applicable only if the ARQ mechanism is enabled."
::= { rbAUWirelessCountersEntry 6 }
rbAUWirelessRTxBytes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of unacknowledged bytes that were retransmitted.
Retransmissions are applicable only to BE and NRT connections provided
the ARQ mechanism is enabled."
::= { rbAUWirelessCountersEntry 7 }
rbAUWirelessRTxRate OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Retransmission Rate in percents:
100*(Bytes Retransmitted)/(ARQ Enabled Bytes Transmitted)."
::= { rbAUWirelessCountersEntry 8 }
rbAUWirelessAUSlot OBJECT-TYPE
SYNTAX Integer32 ( 1 .. 9 )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"For NPU - the physical placement of the card in the chassis (the Slot number 1-4, 7-9).
For MBST - the MBST Wireless port Table index (always 1)."
::= { rbAUWirelessCountersEntry 9 }
END