ADTRAN-GEN-FRAME-RELAY-MIB
|
|
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
-- ******************************************************************
|
|
-- TITLE: ADTRAN GEN FRAME RELAY CLIENT MIB
|
|
-- DATE: September 9, 2010
|
|
--
|
|
-- HISTORY:
|
|
-- yy/mm/dd
|
|
-- 2010/03/24 cb STATUS: PRELIMINARY.
|
|
-- 2010/03/29 jlb - Changed adGenFrameRelayId to adGenFrameRelayID.
|
|
-- adGenFrameRelay and adGenFrameRelayID are now imported from adGenCndSystem.
|
|
-- 2010/04/30 cb - Added adGenFrPVCOperStatus and adGenFrPVCLastChange. Corrected enumerated
|
|
-- values for adGenFrPVCState.
|
|
-- 2010/05/03 cb - Changed read-write types to read-create and moved previous scalars
|
|
-- for Group and PVC information to appropriate slot tables and the
|
|
-- adFrGroupTable.
|
|
-- 2010/06/25 na - Added PM intervals for groups and PVCs
|
|
-- 2010/09/02 cb - Removed adGenFrPVC* oids related to secondary IP gateway
|
|
-- address and primary and secondary gateway subnet masks
|
|
-- 2010/09/09 cb - Added adGenFrPVCDescription and adGenFrPVCMtu
|
|
-- 2010/09/30 glf - correct varbinds in the adGenFrGroupDownAlarmClr, add ifOperStatus so varbinds will
|
|
-- match the adGenFrGroupDownAlarmAct alarm
|
|
|
|
-- ******************************************************************
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
Integer32,
|
|
Counter32,
|
|
TimeTicks,
|
|
Unsigned32 FROM SNMPv2-SMI -- [RFC2578]
|
|
sysName FROM SNMPv2-MIB
|
|
RowStatus,
|
|
TruthValue,
|
|
DisplayString FROM SNMPv2-TC -- [RFC2579]
|
|
InterfaceIndex,
|
|
ifIndex,
|
|
ifOperStatus FROM IF-MIB -- [RFC2863]
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF -- [RFC2580]
|
|
InetAddressType,
|
|
InetAddress FROM INET-ADDRESS-MIB -- [RFC2851]
|
|
adGenFrameRelay,
|
|
adGenFrameRelayID FROM ADTRAN-SHARED-CND-SYSTEM-MIB
|
|
adTrapInformSeqNum FROM ADTRAN-GENTRAPINFORM-MIB
|
|
adTAeSCUTrapAlarmLevel FROM ADTRAN-TAeSCUEXT1-MIB
|
|
adGenPortTrapIdentifier FROM ADTRAN-GENPORT-MIB
|
|
adGenSlotInfoIndex FROM ADTRAN-GENSLOT-MIB
|
|
;
|
|
|
|
adGenFrameRelayMib MODULE-IDENTITY
|
|
LAST-UPDATED "201009090000Z" -- 9/9/2010 00:00GMT
|
|
ORGANIZATION "ADTRAN"
|
|
CONTACT-INFO
|
|
"WG-URL:
|
|
WG-EMail: http://www.adtran.com
|
|
|
|
Contact: ADTRAN
|
|
901 Explorer Blvd
|
|
Huntsville, AL 35806
|
|
|
|
E-mail:
|
|
|
|
"
|
|
DESCRIPTION
|
|
"ADTRAN Generic Frame Relay Management Module"
|
|
|
|
REVISION "201009090000Z" -- 9/9/2010 00:00GMT
|
|
DESCRIPTION
|
|
"cb - Added adGenFrPVCDescription and adGenFrPVCMtu"
|
|
|
|
REVISION "201009020000Z" -- 9/2/2010 00:00GMT
|
|
DESCRIPTION
|
|
"cb - Removed adGenFrPVC* oids related to secondary IP gateway
|
|
address and primary and secondary gateway subnet masks"
|
|
|
|
REVISION "201006250000Z" -- 6/25/2010 00:00GMT
|
|
DESCRIPTION
|
|
"na - Added PM intervals for groups and PVCs."
|
|
|
|
REVISION "201005030000Z" -- 5/3/2010 00:00GMT
|
|
DESCRIPTION
|
|
"cb - Changed read-write types to read-create and moved previous scalars
|
|
for Group and PVC information to appropriate slot tables and the
|
|
adFrGroupTable."
|
|
|
|
REVISION "201004300000Z" -- 4/30/2010 00:00GMT
|
|
DESCRIPTION
|
|
"cb - Added adGenFrPVCOperStatus and adGenFrPVCLastChange. Corrected enumerated
|
|
values for adGenFrPVCState."
|
|
|
|
REVISION "201003290000Z" -- 3/29/2010 00:00GMT
|
|
DESCRIPTION
|
|
"jlb - Changed adGenFrameRelayId to adGenFrameRelayID.
|
|
adGenFrameRelay and adGenFrameRelayID are now imported from adGenCndSystem."
|
|
|
|
REVISION "201003240000Z" -- 3/24/2010 00:00GMT
|
|
DESCRIPTION
|
|
""
|
|
::= { adGenFrameRelayID 1 }
|
|
|
|
adGenFrameRelayMIBObjects OBJECT IDENTIFIER ::= { adGenFrameRelay 1 }
|
|
|
|
-- ******************************************************************
|
|
-- Tables
|
|
-- ******************************************************************
|
|
|
|
adGenFrGroup OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 1 }
|
|
adGenFrLink OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 2 }
|
|
adGenFrPVC OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 3 }
|
|
adGenFrSlot OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 4 }
|
|
|
|
adGenFrAlarmsPrefix OBJECT IDENTIFIER ::= {adGenFrameRelay 2 }
|
|
adGenFrAlarms OBJECT IDENTIFIER ::= {adGenFrAlarmsPrefix 0 }
|
|
|
|
-- ******************************************************************
|
|
-- Textual conventions
|
|
-- ******************************************************************
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay Group Provisioning Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrGroupTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table provides provisioning and status information
|
|
on all frame relay groups / bearer channels."
|
|
::= { adGenFrGroup 2 }
|
|
|
|
adGenFrGroupEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrGroupEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The Frame Relay Group provisioning and status table entry. To
|
|
create a frame relay group, the following procedures are used:
|
|
|
|
(1) The management application creates Frame Relay Group
|
|
entry in the adGenFrGroupTable by setting the
|
|
adGenFrGroupRowStatus to createAndWait(5).
|
|
|
|
This may fail for the following reasons which are reported
|
|
through the adGenFrSlotGroupLastCreateError object:
|
|
|
|
- The selected ifIndex specifies an invalid interface
|
|
- The selected ifIndex is already in use by another Frame
|
|
Relay Group
|
|
|
|
Otherwise, upon successful creation of the row, the group
|
|
is reserved and a corresponding row (identical ifIndex)
|
|
in the frMgtVcSigTable is created.
|
|
|
|
(2) The manager sets other provisioning rows in the
|
|
adGenFrGroupTable and the frMgtVCSigTable that are
|
|
appropriate for the service that is to be provided.
|
|
|
|
(3) Connect a frame relay link to the group to specify which
|
|
interface is to provide service to the group. See the
|
|
adGenFrLinkTable description for more information.
|
|
|
|
(4) If no detectable errors or conflicts in the group
|
|
provisioning is detected, the adGenFrSlotGroupLastCreateError
|
|
object will contain an empty (zero length) string and
|
|
and can be enabled by setting adGenFrGroupRowStatus to active(1).
|
|
|
|
(*) Signaling errors (if enabled) and any provisioning failures
|
|
after setting the adGenFrGroupRowStatus to active(1) can be
|
|
detected by examining the ifTable's ifOperStatus object. If
|
|
this value is not up(1), the adGenFrSlotGroupLastCreateError
|
|
object will contain further diagnostic information as to the
|
|
cause of any failure.
|
|
"
|
|
INDEX { ifIndex }
|
|
::= { adGenFrGroupTable 1 }
|
|
|
|
AdGenFrGroupEntry ::= SEQUENCE {
|
|
adGenFrGroupRowStatus RowStatus,
|
|
adGenFrGroupStatusString DisplayString,
|
|
adGenFrGroupAdminStatus INTEGER,
|
|
adGenFrGroupLmiType INTEGER,
|
|
adGenFrGroupLmiStatus INTEGER,
|
|
adGenFrGroupLmiEnquiryIn Counter32,
|
|
adGenFrGroupLmiEnquiryOut Counter32,
|
|
adGenFrGroupLmiStatusIn Counter32,
|
|
adGenFrGroupLmiStatusOut Counter32,
|
|
adGenFrGroupLmiInvalidIn Counter32,
|
|
adGenFrGroupLmiStatusEnqTimeouts Counter32,
|
|
adGenFrGroupLmiStatusTimeouts Counter32,
|
|
adGenFrGroupClearCounters INTEGER,
|
|
adGenFrGroupClearPmHistory INTEGER,
|
|
adGenFrGroupLinkLastCreateError DisplayString,
|
|
adGenFrGroupPvcLastCreateError DisplayString
|
|
}
|
|
|
|
adGenFrGroupRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The adGenFrGroupRowStatus object allows create, change, and
|
|
delete operations on the Frame Relay Group / Bearer Channel."
|
|
::= { adGenFrGroupEntry 1 }
|
|
|
|
adGenFrGroupStatusString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reason, if any, why the why the group is not in an
|
|
operational state due to provisioning or hardware limitations."
|
|
::= { adGenFrGroupEntry 2 }
|
|
|
|
adGenFrGroupAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2),
|
|
testing(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The desired state of the frame relay group. This object
|
|
must be set to up(1) or testing(3) to enable user data
|
|
transmission on PVCs of this group and for enabling of
|
|
any signaling protocol for this group."
|
|
DEFVAL { down }
|
|
::= { adGenFrGroupEntry 3 }
|
|
|
|
adGenFrGroupLmiType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none(1), -- No signaling
|
|
ansi617d1994(3) -- ANSI T1.617a-1994 Annex D
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The value of this object identifies the local in-channel signaling
|
|
protocol that is used for this frame relay UNI/NNI logical port."
|
|
REFERENCE "American National Standard T1.617-1991, American National Standard
|
|
T1.617a-1994, ITU-T Recommendation Q.933 (03/93)."
|
|
DEFVAL { ansi617d1994 }
|
|
::= { adGenFrGroupEntry 5 }
|
|
|
|
adGenFrGroupLmiStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The value of this object identifies status of local in-channel signaling
|
|
protocol. If the signaling protocol is 'none', then this object will
|
|
report 'up'."
|
|
::= { adGenFrGroupEntry 6 }
|
|
|
|
adGenFrGroupLmiEnquiryIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages received. If the logical
|
|
port is not performing network-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupEntry 7 }
|
|
|
|
adGenFrGroupLmiEnquiryOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages transmitted. If the logical
|
|
port is not performing user-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupEntry 8 }
|
|
|
|
adGenFrGroupLmiStatusIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages received. If the logical port
|
|
is not performing user-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupEntry 9 }
|
|
|
|
adGenFrGroupLmiStatusOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages transmitted. If the logical port
|
|
is not performing network-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupEntry 10 }
|
|
|
|
adGenFrGroupLmiInvalidIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of invalid LMI messages received by this logical port."
|
|
::= { adGenFrGroupEntry 11 }
|
|
|
|
adGenFrGroupLmiStatusEnqTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status Enquiry message in T392 seconds. If the logical port is
|
|
not performing network-side or bidirectional procedures then this
|
|
object is not applicable."
|
|
::= { adGenFrGroupEntry 12 }
|
|
|
|
adGenFrGroupLmiStatusTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status message in a polling interval (within T391 seconds). If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupEntry 13 }
|
|
|
|
adGenFrGroupClearCounters OBJECT-TYPE
|
|
SYNTAX INTEGER { reset(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Writing a value of 1 will reset the interface and signaling
|
|
statistics for this logical port."
|
|
::= { adGenFrGroupEntry 14 }
|
|
|
|
adGenFrGroupClearPmHistory OBJECT-TYPE
|
|
SYNTAX INTEGER { reset(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Writing a value of 1 will reset the interface performance
|
|
monitoring statistics/intervals for this logical port."
|
|
::= { adGenFrGroupEntry 15 }
|
|
|
|
adGenFrGroupLinkLastCreateError OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reason for the last error that occurred while attempting to
|
|
create an entry in the Frame Relay Link Table (adGenFrLinkTable)
|
|
for this specific frame relay group."
|
|
::= { adGenFrGroupEntry 16 }
|
|
|
|
adGenFrGroupPvcLastCreateError OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reason for the last error that occurred while attempting to
|
|
create an entry in the Frame Relay PVC Table (adGenFrPVCTable)
|
|
for this specific frame relay group."
|
|
::= { adGenFrGroupEntry 17 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay Group Current Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrGroupCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrGroupCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The FR Group current table contains performance
|
|
monitoring data for the current 15-minute interval."
|
|
::= { adGenFrGroup 3 }
|
|
|
|
adGenFrGroupCurrentEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrGroupCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the FR Group current table"
|
|
INDEX { ifIndex }
|
|
::= { adGenFrGroupCurrentTable 1 }
|
|
|
|
AdGenFrGroupCurrentEntry ::= SEQUENCE {
|
|
adGenFrGroupCurrentInOctets Counter32,
|
|
adGenFrGroupCurrentInPkts Counter32,
|
|
adGenFrGroupCurrentInDiscards Counter32,
|
|
adGenFrGroupCurrentInErrors Counter32,
|
|
adGenFrGroupCurrentOutOctets Counter32,
|
|
adGenFrGroupCurrentOutPkts Counter32,
|
|
adGenFrGroupCurrentOutDiscards Counter32,
|
|
adGenFrGroupCurrentOutErrors Counter32,
|
|
adGenFrGroupCurrentLmiEnquiryIn Counter32,
|
|
adGenFrGroupCurrentLmiEnquiryOut Counter32,
|
|
adGenFrGroupCurrentLmiStatusIn Counter32,
|
|
adGenFrGroupCurrentLmiStatusOut Counter32,
|
|
adGenFrGroupCurrentLmiInvalidIn Counter32,
|
|
adGenFrGroupCurrentLmiStatusEnqTimeouts Counter32,
|
|
adGenFrGroupCurrentLmiStatusTimeouts Counter32,
|
|
adGenFrGroupCurrentNetworkInactive Counter32
|
|
}
|
|
|
|
adGenFrGroupCurrentInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received on the FR Group."
|
|
|
|
::= { adGenFrGroupCurrentEntry 1 }
|
|
|
|
adGenFrGroupCurrentInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received on the FR Group."
|
|
|
|
::= { adGenFrGroupCurrentEntry 2 }
|
|
|
|
adGenFrGroupCurrentInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of received packets discarded on the FR Group."
|
|
|
|
::= { adGenFrGroupCurrentEntry 3 }
|
|
|
|
adGenFrGroupCurrentInErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of errored packets received on the FR Group."
|
|
|
|
::= { adGenFrGroupCurrentEntry 4 }
|
|
|
|
adGenFrGroupCurrentOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupCurrentEntry 5 }
|
|
|
|
adGenFrGroupCurrentOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupCurrentEntry 6 }
|
|
|
|
adGenFrGroupCurrentOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of transmit packets discarded on the FR Group."
|
|
|
|
::= { adGenFrGroupCurrentEntry 7 }
|
|
|
|
adGenFrGroupCurrentOutErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of errored packets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupCurrentEntry 8 }
|
|
|
|
adGenFrGroupCurrentLmiEnquiryIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages received. If the logical
|
|
port is not performing network-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupCurrentEntry 9 }
|
|
|
|
adGenFrGroupCurrentLmiEnquiryOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages transmitted. If the logical
|
|
port is not performing user-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupCurrentEntry 10 }
|
|
|
|
adGenFrGroupCurrentLmiStatusIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages received. If the logical port
|
|
is not performing user-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupCurrentEntry 11 }
|
|
|
|
adGenFrGroupCurrentLmiStatusOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages transmitted. If the logical port
|
|
is not performing network-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupCurrentEntry 12 }
|
|
|
|
adGenFrGroupCurrentLmiInvalidIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of invalid LMI messages received by this logical port."
|
|
::= { adGenFrGroupCurrentEntry 13 }
|
|
|
|
adGenFrGroupCurrentLmiStatusEnqTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status Enquiry message in T392 seconds. If the logical port is
|
|
not performing network-side or bidirectional procedures then this
|
|
object is not applicable."
|
|
::= { adGenFrGroupCurrentEntry 14 }
|
|
|
|
adGenFrGroupCurrentLmiStatusTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status message in a polling interval (within T391 seconds). If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupCurrentEntry 15 }
|
|
|
|
adGenFrGroupCurrentNetworkInactive OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TODO. If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupCurrentEntry 16 }
|
|
|
|
-- ******************************************************************
|
|
-- The FR Group Interval Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrGroupIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrGroupIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The FR Group Interval Table contains various statistics
|
|
collected by each Frame Relay Group over the previous
|
|
24 hours of operation. The past 24 hours are broken
|
|
into 96 completed 15-minute intervals. Each row in
|
|
this table represents one such interval (identified by
|
|
adGenFrGroupIntervalNumber) and for one specific
|
|
interface (identifed by ifIndex)."
|
|
::= { adGenFrGroup 4 }
|
|
|
|
adGenFrGroupIntervalEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrGroupIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the FR Group Interval table"
|
|
INDEX { ifIndex, adGenFrGroupIntervalNumber }
|
|
::= { adGenFrGroupIntervalTable 1 }
|
|
|
|
AdGenFrGroupIntervalEntry ::= SEQUENCE {
|
|
adGenFrGroupIntervalNumber INTEGER,
|
|
adGenFrGroupIntervalTimeStamp DisplayString,
|
|
adGenFrGroupIntervalInOctets Counter32,
|
|
adGenFrGroupIntervalInPkts Counter32,
|
|
adGenFrGroupIntervalInDiscards Counter32,
|
|
adGenFrGroupIntervalInErrors Counter32,
|
|
adGenFrGroupIntervalOutOctets Counter32,
|
|
adGenFrGroupIntervalOutPkts Counter32,
|
|
adGenFrGroupIntervalOutDiscards Counter32,
|
|
adGenFrGroupIntervalOutErrors Counter32,
|
|
adGenFrGroupIntervalLmiEnquiryIn Counter32,
|
|
adGenFrGroupIntervalLmiEnquiryOut Counter32,
|
|
adGenFrGroupIntervalLmiStatusIn Counter32,
|
|
adGenFrGroupIntervalLmiStatusOut Counter32,
|
|
adGenFrGroupIntervalLmiInvalidIn Counter32,
|
|
adGenFrGroupIntervalLmiStatusEnqTimeouts Counter32,
|
|
adGenFrGroupIntervalLmiStatusTimeouts Counter32,
|
|
adGenFrGroupIntervalNetworkInactive Counter32
|
|
}
|
|
|
|
adGenFrGroupIntervalNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..96)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A number between 1 and 96, where 1 is the most
|
|
recently completed 15-minute interval and 96 is the least
|
|
recently completed 15-minute interval (assuming that all
|
|
96 intervals are valid)."
|
|
::= { adGenFrGroupIntervalEntry 1 }
|
|
|
|
adGenFrGroupIntervalTimeStamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Timestamp of the 15-minute interval"
|
|
|
|
::= { adGenFrGroupIntervalEntry 2 }
|
|
|
|
adGenFrGroupIntervalInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received on the FR Group."
|
|
|
|
::= { adGenFrGroupIntervalEntry 3 }
|
|
|
|
adGenFrGroupIntervalInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received on the FR Group."
|
|
|
|
::= { adGenFrGroupIntervalEntry 4 }
|
|
|
|
adGenFrGroupIntervalInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of received packets discarded on the FR Group."
|
|
|
|
::= { adGenFrGroupIntervalEntry 5 }
|
|
|
|
adGenFrGroupIntervalInErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of errored packets received on the FR Group."
|
|
|
|
::= { adGenFrGroupIntervalEntry 6 }
|
|
|
|
adGenFrGroupIntervalOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupIntervalEntry 7 }
|
|
|
|
adGenFrGroupIntervalOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupIntervalEntry 8 }
|
|
|
|
adGenFrGroupIntervalOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of transmit packets discarded on the FR Group."
|
|
|
|
::= { adGenFrGroupIntervalEntry 9 }
|
|
|
|
adGenFrGroupIntervalOutErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of errored packets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupIntervalEntry 10 }
|
|
|
|
adGenFrGroupIntervalLmiEnquiryIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages received. If the logical
|
|
port is not performing network-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupIntervalEntry 11 }
|
|
|
|
adGenFrGroupIntervalLmiEnquiryOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages transmitted. If the logical
|
|
port is not performing user-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupIntervalEntry 12 }
|
|
|
|
adGenFrGroupIntervalLmiStatusIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages received. If the logical port
|
|
is not performing user-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupIntervalEntry 13 }
|
|
|
|
adGenFrGroupIntervalLmiStatusOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages transmitted. If the logical port
|
|
is not performing network-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupIntervalEntry 14 }
|
|
|
|
adGenFrGroupIntervalLmiInvalidIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of invalid LMI messages received by this logical port."
|
|
::= { adGenFrGroupIntervalEntry 15 }
|
|
|
|
adGenFrGroupIntervalLmiStatusEnqTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status Enquiry message in T392 seconds. If the logical port is
|
|
not performing network-side or bidirectional procedures then this
|
|
object is not applicable."
|
|
::= { adGenFrGroupIntervalEntry 16 }
|
|
|
|
adGenFrGroupIntervalLmiStatusTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status message in a polling interval (within T391 seconds). If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupIntervalEntry 17 }
|
|
|
|
adGenFrGroupIntervalNetworkInactive OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TODO. If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupIntervalEntry 18 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay Group Current Day Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrGroupDayCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrGroupDayCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The FR Group current day table contains performance
|
|
monitoring data for the current 24-hour interval."
|
|
::= { adGenFrGroup 5 }
|
|
|
|
adGenFrGroupDayCurrentEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrGroupDayCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the FR Group current day table"
|
|
INDEX { ifIndex }
|
|
::= { adGenFrGroupDayCurrentTable 1 }
|
|
|
|
AdGenFrGroupDayCurrentEntry ::= SEQUENCE {
|
|
adGenFrGroupDayCurrentInOctets Counter32,
|
|
adGenFrGroupDayCurrentInPkts Counter32,
|
|
adGenFrGroupDayCurrentInDiscards Counter32,
|
|
adGenFrGroupDayCurrentInErrors Counter32,
|
|
adGenFrGroupDayCurrentOutOctets Counter32,
|
|
adGenFrGroupDayCurrentOutPkts Counter32,
|
|
adGenFrGroupDayCurrentOutDiscards Counter32,
|
|
adGenFrGroupDayCurrentOutErrors Counter32,
|
|
adGenFrGroupDayCurrentLmiEnquiryIn Counter32,
|
|
adGenFrGroupDayCurrentLmiEnquiryOut Counter32,
|
|
adGenFrGroupDayCurrentLmiStatusIn Counter32,
|
|
adGenFrGroupDayCurrentLmiStatusOut Counter32,
|
|
adGenFrGroupDayCurrentLmiInvalidIn Counter32,
|
|
adGenFrGroupDayCurrentLmiStatusEnqTimeouts Counter32,
|
|
adGenFrGroupDayCurrentLmiStatusTimeouts Counter32,
|
|
adGenFrGroupDayCurrentNetworkInactive Counter32
|
|
}
|
|
|
|
adGenFrGroupDayCurrentInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received on the FR Group."
|
|
|
|
::= { adGenFrGroupDayCurrentEntry 1 }
|
|
|
|
adGenFrGroupDayCurrentInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received on the FR Group."
|
|
|
|
::= { adGenFrGroupDayCurrentEntry 2 }
|
|
|
|
adGenFrGroupDayCurrentInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of received packets discarded on the FR Group."
|
|
|
|
::= { adGenFrGroupDayCurrentEntry 3 }
|
|
|
|
adGenFrGroupDayCurrentInErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of errored packets received on the FR Group."
|
|
|
|
::= { adGenFrGroupDayCurrentEntry 4 }
|
|
|
|
adGenFrGroupDayCurrentOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupDayCurrentEntry 5 }
|
|
|
|
adGenFrGroupDayCurrentOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupDayCurrentEntry 6 }
|
|
|
|
adGenFrGroupDayCurrentOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of transmit packets discarded on the FR Group."
|
|
|
|
::= { adGenFrGroupDayCurrentEntry 7 }
|
|
|
|
adGenFrGroupDayCurrentOutErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of errored packets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupDayCurrentEntry 8 }
|
|
|
|
adGenFrGroupDayCurrentLmiEnquiryIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages received. If the logical
|
|
port is not performing network-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupDayCurrentEntry 9 }
|
|
|
|
adGenFrGroupDayCurrentLmiEnquiryOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages transmitted. If the logical
|
|
port is not performing user-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupDayCurrentEntry 10 }
|
|
|
|
adGenFrGroupDayCurrentLmiStatusIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages received. If the logical port
|
|
is not performing user-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupDayCurrentEntry 11 }
|
|
|
|
adGenFrGroupDayCurrentLmiStatusOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages transmitted. If the logical port
|
|
is not performing network-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupDayCurrentEntry 12 }
|
|
|
|
adGenFrGroupDayCurrentLmiInvalidIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of invalid LMI messages received by this logical port."
|
|
::= { adGenFrGroupDayCurrentEntry 13 }
|
|
|
|
adGenFrGroupDayCurrentLmiStatusEnqTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status Enquiry message in T392 seconds. If the logical port is
|
|
not performing network-side or bidirectional procedures then this
|
|
object is not applicable."
|
|
::= { adGenFrGroupDayCurrentEntry 14 }
|
|
|
|
adGenFrGroupDayCurrentLmiStatusTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status message in a polling interval (within T391 seconds). If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupDayCurrentEntry 15 }
|
|
|
|
adGenFrGroupDayCurrentNetworkInactive OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TODO. If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupDayCurrentEntry 16 }
|
|
|
|
-- ******************************************************************
|
|
-- The FR Group Day Interval Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrGroupDayIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrGroupDayIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The FR Group Day Interval Table contains various statistics
|
|
collected by each Frame Relay Group over the previous 7 days of
|
|
operation. The past 7 days are broken into completed 24-hour
|
|
intervals. Each row in this table represents one such interval
|
|
(identified by adGenFrGroupDayIntervalNumber) and for one specific
|
|
interface (identifed by ifIndex)."
|
|
::= { adGenFrGroup 6 }
|
|
|
|
adGenFrGroupDayIntervalEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrGroupDayIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the FR Group Interval table"
|
|
INDEX { ifIndex, adGenFrGroupDayIntervalNumber }
|
|
::= { adGenFrGroupDayIntervalTable 1 }
|
|
|
|
AdGenFrGroupDayIntervalEntry ::= SEQUENCE {
|
|
adGenFrGroupDayIntervalNumber INTEGER,
|
|
adGenFrGroupDayIntervalTimeStamp DisplayString,
|
|
adGenFrGroupDayIntervalInOctets Counter32,
|
|
adGenFrGroupDayIntervalInPkts Counter32,
|
|
adGenFrGroupDayIntervalInDiscards Counter32,
|
|
adGenFrGroupDayIntervalInErrors Counter32,
|
|
adGenFrGroupDayIntervalOutOctets Counter32,
|
|
adGenFrGroupDayIntervalOutPkts Counter32,
|
|
adGenFrGroupDayIntervalOutDiscards Counter32,
|
|
adGenFrGroupDayIntervalOutErrors Counter32,
|
|
adGenFrGroupDayIntervalLmiEnquiryIn Counter32,
|
|
adGenFrGroupDayIntervalLmiEnquiryOut Counter32,
|
|
adGenFrGroupDayIntervalLmiStatusIn Counter32,
|
|
adGenFrGroupDayIntervalLmiStatusOut Counter32,
|
|
adGenFrGroupDayIntervalLmiInvalidIn Counter32,
|
|
adGenFrGroupDayIntervalLmiStatusEnqTimeouts Counter32,
|
|
adGenFrGroupDayIntervalLmiStatusTimeouts Counter32,
|
|
adGenFrGroupDayIntervalNetworkInactive Counter32
|
|
}
|
|
|
|
adGenFrGroupDayIntervalNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A number between 1 and 7, where 1 is the most
|
|
recently completed 24-hour interval and 96 is the least
|
|
recently completed 24-hour interval (assuming that all
|
|
7 intervals are valid)."
|
|
::= { adGenFrGroupDayIntervalEntry 1 }
|
|
|
|
adGenFrGroupDayIntervalTimeStamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Timestamp of the 15-minute interval"
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 2 }
|
|
|
|
adGenFrGroupDayIntervalInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received on the FR Group."
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 3 }
|
|
|
|
adGenFrGroupDayIntervalInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received on the FR Group."
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 4 }
|
|
|
|
adGenFrGroupDayIntervalInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of received packets discarded on the FR Group."
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 5 }
|
|
|
|
adGenFrGroupDayIntervalInErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of errored packets received on the FR Group."
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 6 }
|
|
|
|
adGenFrGroupDayIntervalOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 7 }
|
|
|
|
adGenFrGroupDayIntervalOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 8 }
|
|
|
|
adGenFrGroupDayIntervalOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of transmit packets discarded on the FR Group."
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 9 }
|
|
|
|
adGenFrGroupDayIntervalOutErrors OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of errored packets transmitted on the FR Group."
|
|
|
|
::= { adGenFrGroupDayIntervalEntry 10 }
|
|
|
|
adGenFrGroupDayIntervalLmiEnquiryIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages received. If the logical
|
|
port is not performing network-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupDayIntervalEntry 11 }
|
|
|
|
adGenFrGroupDayIntervalLmiEnquiryOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status Enquiry messages transmitted. If the logical
|
|
port is not performing user-side or bidirectional procedures
|
|
then this object is not applicable."
|
|
::= { adGenFrGroupDayIntervalEntry 12 }
|
|
|
|
adGenFrGroupDayIntervalLmiStatusIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages received. If the logical port
|
|
is not performing user-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupDayIntervalEntry 13 }
|
|
|
|
adGenFrGroupDayIntervalLmiStatusOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of Status messages transmitted. If the logical port
|
|
is not performing network-side or bidirectional procedures then
|
|
this object is not applicable."
|
|
::= { adGenFrGroupDayIntervalEntry 14 }
|
|
|
|
adGenFrGroupDayIntervalLmiInvalidIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of invalid LMI messages received by this logical port."
|
|
::= { adGenFrGroupDayIntervalEntry 15 }
|
|
|
|
adGenFrGroupDayIntervalLmiStatusEnqTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status Enquiry message in T392 seconds. If the logical port is
|
|
not performing network-side or bidirectional procedures then this
|
|
object is not applicable."
|
|
::= { adGenFrGroupDayIntervalEntry 16 }
|
|
|
|
adGenFrGroupDayIntervalLmiStatusTimeouts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of times this logical port has failed to receive a
|
|
Status message in a polling interval (within T391 seconds). If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupDayIntervalEntry 17 }
|
|
|
|
adGenFrGroupDayIntervalNetworkInactive OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "TODO. If
|
|
the logical port is not performing user-side or bidirectional
|
|
procedures then this object is not applicable."
|
|
::= { adGenFrGroupDayIntervalEntry 18 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay Link Provisioning Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table provides provisioning and status information
|
|
on all frame relay links."
|
|
::= { adGenFrLink 2 }
|
|
|
|
adGenFrLinkEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The Frame Relay Link provisioning and status table entry."
|
|
INDEX { adGenFrLinkGroupIfIndex, adGenFrLinkIfIndex, adGenFrLinkBundleId }
|
|
::= { adGenFrLinkTable 1 }
|
|
|
|
AdGenFrLinkEntry ::= SEQUENCE {
|
|
adGenFrLinkGroupIfIndex InterfaceIndex,
|
|
adGenFrLinkIfIndex InterfaceIndex,
|
|
adGenFrLinkBundleId INTEGER,
|
|
adGenFrLinkRowStatus RowStatus,
|
|
adGenFrLinkTimeslots DisplayString,
|
|
adGenFrLinkStatusString DisplayString
|
|
}
|
|
|
|
adGenFrLinkGroupIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object represents the frame relay group to which
|
|
this frame relay link is to be connected."
|
|
::= { adGenFrLinkEntry 1 }
|
|
|
|
adGenFrLinkIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object represents the physical T1/E1 link to which
|
|
this frame relay link is to constructed from."
|
|
::= { adGenFrLinkEntry 2 }
|
|
|
|
adGenFrLinkBundleId OBJECT-TYPE
|
|
SYNTAX INTEGER (1..32)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object represents the ds0 bundle ID number for this
|
|
frame relay link. Some hardware implementations will
|
|
only support a single ds0 bundle per T1/E1 link. For
|
|
implementations with this limitation, the bundle ID may
|
|
only be 1."
|
|
::= { adGenFrLinkEntry 3 }
|
|
|
|
adGenFrLinkRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The adGenFrLinkRowStatus object allows create, change, and
|
|
delete operations on the Frame Relay link."
|
|
::= { adGenFrLinkEntry 4 }
|
|
|
|
adGenFrLinkTimeslots OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The adGenFrLinkTimeslots is a string representation of
|
|
the timeslot or timeslot range that describes the active
|
|
ds0's for this link.
|
|
|
|
For example:
|
|
|
|
To indicate that timeslots 3 through 8 are active, the
|
|
string would be '3-8'.
|
|
|
|
To indicate a single ds0, such as timeslot 18, the string
|
|
would be '18'."
|
|
DEFVAL { "1-24" }
|
|
::= { adGenFrLinkEntry 5 }
|
|
|
|
adGenFrLinkStatusString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reason, if any, why the frame relay link is
|
|
not in an operational state due to provisioning or
|
|
hardware limitations."
|
|
::= { adGenFrLinkEntry 7 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay PVC Provisioning Table
|
|
-- ******************************************************************
|
|
|
|
-- adGenFrPVC OBJECT IDENTIFIER ::= { adGenFrameRelayMIBObjects 3 }
|
|
|
|
adGenFrPVCTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrPVCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table provides provisioning and status information
|
|
on all frame relay virtual circuits (PVCs)."
|
|
::= { adGenFrPVC 4 }
|
|
|
|
adGenFrPVCEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrPVCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The Frame Relay PVC supplemental provisioning and status
|
|
table entry. To create a Frame Relay PVC, the following
|
|
procedures are used:
|
|
|
|
(1) The management application creates Frame Relay PVC by
|
|
creating entry in the frPVCEndptTable by setting the
|
|
frPVCEndPtRowStatus to createAndWait(5).
|
|
|
|
This may fail for the following reasons which are reported
|
|
through the associated frame-relay group's
|
|
adGenFrGroupPvcLastCreateError object.
|
|
|
|
- The selected adGenFrPVCIfIndex specifies an invalid interface
|
|
- The selected frPVCEndptDLCIIndex specifies an invalid or
|
|
reserved DLCI value
|
|
- The selected frPVCEndptDLCIIndex is already in use by
|
|
another Frame Relay PVC on this group
|
|
- The maximum number of PVCs for this access module has
|
|
been created and resources are not available for creation
|
|
of another PVC.
|
|
|
|
Otherwise, upon successful creation of the row, the PVC
|
|
is reserved and a corresponding row (identical ifIndex
|
|
(adGenFrPVCIfIndex) and DLCI (adGenFrPVCDLCIIndex) in
|
|
this table is created.
|
|
|
|
(2) The manager sets other provisioning rows in the
|
|
adGenFrPVCTable and the frPVCEndptTable that are
|
|
appropriate for the service that is to be provided.
|
|
|
|
(3) Provisioning failures or conflicts with other provisioning
|
|
for a PVC can be detected by examining the adGenFrPVCStatus
|
|
string.
|
|
"
|
|
INDEX { ifIndex, adGenFrPVCDLCIIndex }
|
|
::= { adGenFrPVCTable 1 }
|
|
|
|
AdGenFrPVCEntry ::= SEQUENCE {
|
|
adGenFrPVCIfIndex InterfaceIndex,
|
|
adGenFrPVCDLCIIndex Integer32,
|
|
adGenFrPVCStatusString DisplayString,
|
|
adGenFrPVCAdminStatus INTEGER,
|
|
adGenFrPVCState INTEGER,
|
|
|
|
adGenFrPVCEncapsulation INTEGER,
|
|
adGenFrPVCPrimaryPeerIpAddressType InetAddressType,
|
|
adGenFrPVCPrimaryPeerIpAddress InetAddress,
|
|
adGenFrPVCSecondaryPeerAddressType InetAddressType,
|
|
adGenFrPVCSecondaryPeerIpAddress InetAddress,
|
|
adGenFrPVCPrimaryGatewayAddressType InetAddressType,
|
|
adGenFrPVCPrimaryGatewayAddress InetAddress,
|
|
adGenFrPVCInverseArpEnable TruthValue,
|
|
adGenFrPVCLearnedPrimaryPeerIpAddressType InetAddressType,
|
|
adGenFrPVCLearnedPrimaryPeerIpAddress InetAddress,
|
|
adGenFrPVCLearnedSecondaryPeerAddressType InetAddressType,
|
|
adGenFrPVCLearnedSecondaryPeerIpAddress InetAddress,
|
|
adGenFrPVCClearCounters INTEGER,
|
|
adGenFrPVCClearPmHistory INTEGER,
|
|
adGenFrPVCOperStatus INTEGER,
|
|
adGenFrPVCLastChange TimeTicks,
|
|
adGenFrPVCDescription DisplayString,
|
|
adGenFrPVCMtu Integer32
|
|
}
|
|
|
|
adGenFrPVCIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The value of this object is equal to the ifIndex
|
|
value for this PVC end-point."
|
|
::= { adGenFrPVCEntry 1 }
|
|
|
|
adGenFrPVCDLCIIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (16..991)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The value of this object is equal to the DLCI
|
|
value for this PVC end-point.
|
|
|
|
The values are restricted to the legal range for
|
|
the size of address field supported by the
|
|
application which is currently 10-bits."
|
|
REFERENCE "ITU Q.922"
|
|
|
|
::= { adGenFrPVCEntry 2 }
|
|
|
|
adGenFrPVCStatusString OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reason, if any, why the why the PVC is not in an
|
|
operational state due to provisioning or hardware limitations."
|
|
::= { adGenFrPVCEntry 3 }
|
|
|
|
adGenFrPVCAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2),
|
|
testing(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The desired state of the frame relay PVC. This object
|
|
must be set to up(1) or testing(3) to enable user data
|
|
transmission on the PVC."
|
|
DEFVAL { down }
|
|
::= { adGenFrPVCEntry 4 }
|
|
|
|
adGenFrPVCState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
new(1), -- PVC is new
|
|
none(2), -- in-channel signaling is disabled or starting
|
|
active(3), -- PVC is operational
|
|
inactive(4),-- PVC is not operational
|
|
deleted(5) -- PVC is marked for deletion
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object provides the operation state information of
|
|
the PVC."
|
|
::= { adGenFrPVCEntry 5 }
|
|
|
|
adGenFrPVCEncapsulation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ipv4(1)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The network protocol encapsulated on this frame relay PVC."
|
|
DEFVAL { ipv4 }
|
|
::= { adGenFrPVCEntry 6 }
|
|
|
|
adGenFrPVCPrimaryPeerIpAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "IP address type (ipv4 or ipv6) represented by in the
|
|
adGenFrPVCPrimaryPeerIpAddress column. This oid is only
|
|
significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
|
|
DEFVAL { ipv4 }
|
|
::= { adGenFrPVCEntry 7 }
|
|
|
|
adGenFrPVCPrimaryPeerIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Provisioned Primary Peer IP address. If this object
|
|
is set to a valid non-zero IP address and Inverse ARP
|
|
is enabled, the address much match that learned from
|
|
the Inverse ARP protocol. If they do not match, nor
|
|
does the adGenFrPVCSecondaryIpAddress match, then
|
|
user data transmission over the PVC will be disabled
|
|
and the adGenFrPVCState object will report inactive(3)."
|
|
::= { adGenFrPVCEntry 8 }
|
|
|
|
adGenFrPVCSecondaryPeerAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "IP address type (ipv4 or ipv6) represented by in the
|
|
adGenFrPVCSecondaryPeerIpAddress column. This oid is only
|
|
significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
|
|
DEFVAL { ipv4 }
|
|
::= { adGenFrPVCEntry 9 }
|
|
|
|
adGenFrPVCSecondaryPeerIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Provisioned Secondary Peer IP address. If this object
|
|
is set to a valid non-zero IP address and Inverse ARP
|
|
is enabled, the address much match that learned from
|
|
the Inverse ARP protocol. If they do not match, nor
|
|
does the adGenFrPVCPrimaryIpAddress match, then
|
|
user data transmission over the PVC will be disabled
|
|
and the adGenFrPVCState object will report inactive(3)."
|
|
::= { adGenFrPVCEntry 10 }
|
|
|
|
adGenFrPVCPrimaryGatewayAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "IP address type (ipv4 or ipv6) represented by in the
|
|
adGenFrPVCPrimaryGatewayAddress column. This oid is only
|
|
significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
|
|
DEFVAL { ipv4 }
|
|
::= { adGenFrPVCEntry 11 }
|
|
|
|
adGenFrPVCPrimaryGatewayAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "The primary gateway IP address for the peer. This oid is only
|
|
significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
|
|
::= { adGenFrPVCEntry 12 }
|
|
|
|
adGenFrPVCInverseArpEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Setting this value to true enables transmission of Inverse ARP
|
|
requests by this frame relay PVC. If the encapsulation protocol
|
|
is not ipv4, this oid has no effect. Note that if InARP request
|
|
transmissions are disabled and an InARP request is received from
|
|
the peer, a InARP response will be transmitted if appropriate."
|
|
DEFVAL { true }
|
|
::= { adGenFrPVCEntry 19 }
|
|
|
|
adGenFrPVCLearnedPrimaryPeerIpAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Learned IP address type (ipv4 or ipv6) represented by in the
|
|
adGenFrPVCLearnedPrimaryPeerIpAddress column. This oid is only
|
|
significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
|
|
::= { adGenFrPVCEntry 20 }
|
|
|
|
adGenFrPVCLearnedPrimaryPeerIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Learned Primary Peer IP address. This value
|
|
is learned through the Inverse ARP protocol mechanism."
|
|
::= { adGenFrPVCEntry 21 }
|
|
|
|
adGenFrPVCLearnedSecondaryPeerAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Learned IP address type (ipv4 or ipv6) represented by in the
|
|
adGenFrPVCLearnedSecondaryPeerIpAddress column. This oid is only
|
|
significant if the adGenFrPVCEncapsulation is ipv4 or ipv6."
|
|
::= { adGenFrPVCEntry 22 }
|
|
|
|
adGenFrPVCLearnedSecondaryPeerIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Learned Secondary Peer IP address. This value
|
|
is learned through the Inverse ARP protocol mechanism."
|
|
::= { adGenFrPVCEntry 23 }
|
|
|
|
adGenFrPVCClearCounters OBJECT-TYPE
|
|
SYNTAX INTEGER { reset(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Writing a value of 1 will reset the PVC statistics for
|
|
this logical port."
|
|
::= { adGenFrPVCEntry 24 }
|
|
|
|
adGenFrPVCClearPmHistory OBJECT-TYPE
|
|
SYNTAX INTEGER { reset(1) }
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION "Writing a value of 1 will reset the interface performance
|
|
monitoring statistics/intervals for this logical port."
|
|
::= { adGenFrPVCEntry 25 }
|
|
|
|
adGenFrPVCOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1), -- ready to pass packets
|
|
down(2),
|
|
testing(3), -- not expected
|
|
unknown(4), -- status can not be determined
|
|
-- for some reason.
|
|
dormant(5),
|
|
notPresent(6), -- some component is missing
|
|
lowerLayerDown(7) -- down due to state of
|
|
-- lower-layer interface(s)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational state of the PVC."
|
|
::= { adGenFrPVCEntry 26 }
|
|
|
|
adGenFrPVCLastChange OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime at the time the PVC
|
|
entered its current operational state. If the current
|
|
state was entered prior to the last re-initialization
|
|
of the local network management subsystem, then this
|
|
object contains a zero value."
|
|
::= { adGenFrPVCEntry 27 }
|
|
|
|
adGenFrPVCDescription OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A descriptive name for the PVC"
|
|
::= { adGenFrPVCEntry 28 }
|
|
|
|
adGenFrPVCMtu OBJECT-TYPE
|
|
SYNTAX Integer32 (262..1600)
|
|
UNITS "Octets"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The size of the largest packet which can be
|
|
sent/received on the interface, specified in octets.
|
|
For a PVC, this is the size of the frame relay payload
|
|
and does not count the HDLC start/end flags, Frame Relay
|
|
address field, or the CRC-16 trailer."
|
|
DEFVAL { 1500 }
|
|
::= { adGenFrPVCEntry 29 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay PVC Current Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrPVCCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrPVCCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The FR PVC current table contains performance
|
|
monitoring data for the current 15-minute interval."
|
|
::= { adGenFrPVC 5 }
|
|
|
|
adGenFrPVCCurrentEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrPVCCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the FR PVC Current table"
|
|
INDEX { ifIndex, adGenFrPVCDLCIIndex }
|
|
::= { adGenFrPVCCurrentTable 1 }
|
|
|
|
AdGenFrPVCCurrentEntry ::= SEQUENCE {
|
|
adGenFrPVCCurrentInOctets Counter32,
|
|
adGenFrPVCCurrentInPkts Counter32,
|
|
adGenFrPVCCurrentInDiscards Counter32,
|
|
adGenFrPVCCurrentOutOctets Counter32,
|
|
adGenFrPVCCurrentOutPkts Counter32,
|
|
adGenFrPVCCurrentOutDiscards Counter32,
|
|
adGenFrPVCCurrentPktsFECN1In Counter32,
|
|
adGenFrPVCCurrentPktsFECN1Out Counter32,
|
|
adGenFrPVCCurrentPktsBECN1In Counter32,
|
|
adGenFrPVCCurrentPktsBECN1Out Counter32,
|
|
adGenFrPVCCurrentPktsDE1In Counter32,
|
|
adGenFrPVCCurrentPktsDE1Out Counter32,
|
|
adGenFrPVCCurrentOctetsDE1In Counter32,
|
|
adGenFrPVCCurrentOctetsDE1Out Counter32
|
|
}
|
|
|
|
adGenFrPVCCurrentInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received on the FR PVC."
|
|
|
|
::= { adGenFrPVCCurrentEntry 1 }
|
|
|
|
adGenFrPVCCurrentInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received on the FR PVC."
|
|
|
|
::= { adGenFrPVCCurrentEntry 2 }
|
|
|
|
adGenFrPVCCurrentInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of received packets discarded on the FR PVC."
|
|
|
|
::= { adGenFrPVCCurrentEntry 3 }
|
|
|
|
adGenFrPVCCurrentOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted on the FR PVC."
|
|
|
|
::= { adGenFrPVCCurrentEntry 5 }
|
|
|
|
adGenFrPVCCurrentOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted on the FR PVC."
|
|
|
|
::= { adGenFrPVCCurrentEntry 6 }
|
|
|
|
adGenFrPVCCurrentOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of transmit packets discarded on the FR PVC."
|
|
|
|
::= { adGenFrPVCCurrentEntry 7 }
|
|
|
|
adGenFrPVCCurrentPktsFECN1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Forward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCCurrentEntry 9 }
|
|
|
|
adGenFrPVCCurrentPktsFECN1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Forward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCCurrentEntry 10 }
|
|
|
|
adGenFrPVCCurrentPktsBECN1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Backward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCCurrentEntry 11 }
|
|
|
|
adGenFrPVCCurrentPktsBECN1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Backward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCCurrentEntry 12 }
|
|
|
|
adGenFrPVCCurrentPktsDE1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCCurrentEntry 13 }
|
|
|
|
adGenFrPVCCurrentPktsDE1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCCurrentEntry 14 }
|
|
|
|
adGenFrPVCCurrentOctetsDE1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCCurrentEntry 15 }
|
|
|
|
adGenFrPVCCurrentOctetsDE1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCCurrentEntry 16 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay PVC Interval Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrPVCIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrPVCIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The FR PVC Interval Table contains various statistics
|
|
collected by each Frame Relay PVC over the previous
|
|
24 hours of operation. The past 24 hours are broken
|
|
into 96 completed 15-minute intervals. Each row in
|
|
this table represents one such interval (identified by
|
|
adGenFrPVCIntervalNumber) and for one specific
|
|
interface (identifed by ifIndex and
|
|
adGenFrPVCDLCIIndex)."
|
|
::= { adGenFrPVC 6 }
|
|
|
|
adGenFrPVCIntervalEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrPVCIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the FR PVC Interval table"
|
|
INDEX { ifIndex, adGenFrPVCDLCIIndex, adGenFrPVCIntervalNumber }
|
|
::= { adGenFrPVCIntervalTable 1 }
|
|
|
|
AdGenFrPVCIntervalEntry ::= SEQUENCE {
|
|
adGenFrPVCIntervalNumber INTEGER,
|
|
adGenFrPVCIntervalTimeStamp DisplayString,
|
|
adGenFrPVCIntervalInOctets Counter32,
|
|
adGenFrPVCIntervalInPkts Counter32,
|
|
adGenFrPVCIntervalInDiscards Counter32,
|
|
adGenFrPVCIntervalOutOctets Counter32,
|
|
adGenFrPVCIntervalOutPkts Counter32,
|
|
adGenFrPVCIntervalOutDiscards Counter32,
|
|
adGenFrPVCIntervalPktsFECN1In Counter32,
|
|
adGenFrPVCIntervalPktsFECN1Out Counter32,
|
|
adGenFrPVCIntervalPktsBECN1In Counter32,
|
|
adGenFrPVCIntervalPktsBECN1Out Counter32,
|
|
adGenFrPVCIntervalPktsDE1In Counter32,
|
|
adGenFrPVCIntervalPktsDE1Out Counter32,
|
|
adGenFrPVCIntervalOctetsDE1In Counter32,
|
|
adGenFrPVCIntervalOctetsDE1Out Counter32
|
|
}
|
|
|
|
adGenFrPVCIntervalNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..96)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A number between 1 and 96, where 1 is the most
|
|
recently completed 15-minute interval and 96 is the least
|
|
recently completed 15-minute interval (assuming that all
|
|
96 intervals are valid)."
|
|
::= { adGenFrPVCIntervalEntry 1 }
|
|
|
|
adGenFrPVCIntervalTimeStamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Timestamp of the 15-minute interval"
|
|
|
|
::= { adGenFrPVCIntervalEntry 2 }
|
|
|
|
adGenFrPVCIntervalInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received on the FR PVC."
|
|
|
|
::= { adGenFrPVCIntervalEntry 3 }
|
|
|
|
adGenFrPVCIntervalInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received on the FR PVC."
|
|
|
|
::= { adGenFrPVCIntervalEntry 4 }
|
|
|
|
adGenFrPVCIntervalInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of received packets discarded on the FR PVC."
|
|
|
|
::= { adGenFrPVCIntervalEntry 5 }
|
|
|
|
adGenFrPVCIntervalOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted on the FR PVC."
|
|
|
|
::= { adGenFrPVCIntervalEntry 7 }
|
|
|
|
adGenFrPVCIntervalOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted on the FR PVC."
|
|
|
|
::= { adGenFrPVCIntervalEntry 8 }
|
|
|
|
adGenFrPVCIntervalOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of transmit packets discarded on the FR PVC."
|
|
|
|
::= { adGenFrPVCIntervalEntry 9 }
|
|
|
|
adGenFrPVCIntervalPktsFECN1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Forward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCIntervalEntry 11 }
|
|
|
|
adGenFrPVCIntervalPktsFECN1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Forward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCIntervalEntry 12 }
|
|
|
|
adGenFrPVCIntervalPktsBECN1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Backward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCIntervalEntry 13 }
|
|
|
|
adGenFrPVCIntervalPktsBECN1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Backward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCIntervalEntry 14 }
|
|
|
|
adGenFrPVCIntervalPktsDE1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCIntervalEntry 15 }
|
|
|
|
adGenFrPVCIntervalPktsDE1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCIntervalEntry 16 }
|
|
|
|
adGenFrPVCIntervalOctetsDE1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCIntervalEntry 17 }
|
|
|
|
adGenFrPVCIntervalOctetsDE1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCIntervalEntry 18 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay PVC Day Current Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrPVCDayCurrentTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrPVCDayCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The FR PVC current day table contains performance
|
|
monitoring data for the current 24-hour interval."
|
|
::= { adGenFrPVC 7 }
|
|
|
|
adGenFrPVCDayCurrentEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrPVCDayCurrentEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the FR PVC current day table"
|
|
INDEX { ifIndex, adGenFrPVCDLCIIndex }
|
|
::= { adGenFrPVCDayCurrentTable 1 }
|
|
|
|
AdGenFrPVCDayCurrentEntry ::= SEQUENCE {
|
|
adGenFrPVCDayCurrentInOctets Counter32,
|
|
adGenFrPVCDayCurrentInPkts Counter32,
|
|
adGenFrPVCDayCurrentInDiscards Counter32,
|
|
adGenFrPVCDayCurrentOutOctets Counter32,
|
|
adGenFrPVCDayCurrentOutPkts Counter32,
|
|
adGenFrPVCDayCurrentOutDiscards Counter32,
|
|
adGenFrPVCDayCurrentPktsFECN1In Counter32,
|
|
adGenFrPVCDayCurrentPktsFECN1Out Counter32,
|
|
adGenFrPVCDayCurrentPktsBECN1In Counter32,
|
|
adGenFrPVCDayCurrentPktsBECN1Out Counter32,
|
|
adGenFrPVCDayCurrentPktsDE1In Counter32,
|
|
adGenFrPVCDayCurrentPktsDE1Out Counter32,
|
|
adGenFrPVCDayCurrentOctetsDE1In Counter32,
|
|
adGenFrPVCDayCurrentOctetsDE1Out Counter32
|
|
}
|
|
|
|
adGenFrPVCDayCurrentInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayCurrentEntry 1 }
|
|
|
|
adGenFrPVCDayCurrentInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayCurrentEntry 2 }
|
|
|
|
adGenFrPVCDayCurrentInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of received packets discarded on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayCurrentEntry 3 }
|
|
|
|
adGenFrPVCDayCurrentOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayCurrentEntry 5 }
|
|
|
|
adGenFrPVCDayCurrentOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayCurrentEntry 6 }
|
|
|
|
adGenFrPVCDayCurrentOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of transmit packets discarded on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayCurrentEntry 7 }
|
|
|
|
adGenFrPVCDayCurrentPktsFECN1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Forward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCDayCurrentEntry 9 }
|
|
|
|
adGenFrPVCDayCurrentPktsFECN1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Forward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCDayCurrentEntry 10 }
|
|
|
|
adGenFrPVCDayCurrentPktsBECN1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Backward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCDayCurrentEntry 11 }
|
|
|
|
adGenFrPVCDayCurrentPktsBECN1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Backward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCDayCurrentEntry 12 }
|
|
|
|
adGenFrPVCDayCurrentPktsDE1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCDayCurrentEntry 13 }
|
|
|
|
adGenFrPVCDayCurrentPktsDE1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCDayCurrentEntry 14 }
|
|
|
|
adGenFrPVCDayCurrentOctetsDE1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCDayCurrentEntry 15 }
|
|
|
|
adGenFrPVCDayCurrentOctetsDE1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCDayCurrentEntry 16 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay PVC Day Interval Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrPVCDayIntervalTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrPVCDayIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "The FR PVC Day Interval Table contains various statistics
|
|
collected by each Frame Relay PVC over the previous
|
|
7 days of operation. The past 7 days are broken
|
|
into completed 24-hour intervals. Each row in
|
|
this table represents one such interval (identified by
|
|
adGenFrPVCIntervalNumber) and for one specific
|
|
interface (identifed by ifIndex and
|
|
adGenFrPVCDLCIIndex)."
|
|
::= { adGenFrPVC 8 }
|
|
|
|
adGenFrPVCDayIntervalEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrPVCDayIntervalEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in the FR PVC Day Interval table"
|
|
INDEX { ifIndex, adGenFrPVCDLCIIndex, adGenFrPVCDayIntervalNumber }
|
|
::= { adGenFrPVCDayIntervalTable 1 }
|
|
|
|
AdGenFrPVCDayIntervalEntry ::= SEQUENCE {
|
|
adGenFrPVCDayIntervalNumber INTEGER,
|
|
adGenFrPVCDayIntervalTimeStamp DisplayString,
|
|
adGenFrPVCDayIntervalInOctets Counter32,
|
|
adGenFrPVCDayIntervalInPkts Counter32,
|
|
adGenFrPVCDayIntervalInDiscards Counter32,
|
|
adGenFrPVCDayIntervalOutOctets Counter32,
|
|
adGenFrPVCDayIntervalOutPkts Counter32,
|
|
adGenFrPVCDayIntervalOutDiscards Counter32,
|
|
adGenFrPVCDayIntervalPktsFECN1In Counter32,
|
|
adGenFrPVCDayIntervalPktsFECN1Out Counter32,
|
|
adGenFrPVCDayIntervalPktsBECN1In Counter32,
|
|
adGenFrPVCDayIntervalPktsBECN1Out Counter32,
|
|
adGenFrPVCDayIntervalPktsDE1In Counter32,
|
|
adGenFrPVCDayIntervalPktsDE1Out Counter32,
|
|
adGenFrPVCDayIntervalOctetsDE1In Counter32,
|
|
adGenFrPVCDayIntervalOctetsDE1Out Counter32
|
|
}
|
|
|
|
adGenFrPVCDayIntervalNumber OBJECT-TYPE
|
|
SYNTAX INTEGER (1..7)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A number between 1 and 7, where 1 is the most
|
|
recently completed 24-hour interval and 96 is the least
|
|
recently completed 24-hour interval (assuming that all
|
|
7 intervals are valid)."
|
|
::= { adGenFrPVCDayIntervalEntry 1 }
|
|
|
|
adGenFrPVCDayIntervalTimeStamp OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Timestamp of the 15-minute interval"
|
|
|
|
::= { adGenFrPVCDayIntervalEntry 2 }
|
|
|
|
adGenFrPVCDayIntervalInOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayIntervalEntry 3 }
|
|
|
|
adGenFrPVCDayIntervalInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayIntervalEntry 4 }
|
|
|
|
adGenFrPVCDayIntervalInDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of received packets discarded on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayIntervalEntry 5 }
|
|
|
|
adGenFrPVCDayIntervalOutOctets OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayIntervalEntry 7 }
|
|
|
|
adGenFrPVCDayIntervalOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayIntervalEntry 8 }
|
|
|
|
adGenFrPVCDayIntervalOutDiscards OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of transmit packets discarded on the FR PVC."
|
|
|
|
::= { adGenFrPVCDayIntervalEntry 9 }
|
|
|
|
adGenFrPVCDayIntervalPktsFECN1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Forward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCDayIntervalEntry 11 }
|
|
|
|
adGenFrPVCDayIntervalPktsFECN1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Forward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCDayIntervalEntry 12 }
|
|
|
|
adGenFrPVCDayIntervalPktsBECN1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Backward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCDayIntervalEntry 13 }
|
|
|
|
adGenFrPVCDayIntervalPktsBECN1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Backward Explicit
|
|
Congestion Notification bit set to 1."
|
|
::= { adGenFrPVCDayIntervalEntry 14 }
|
|
|
|
adGenFrPVCDayIntervalPktsDE1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets received with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCDayIntervalEntry 15 }
|
|
|
|
adGenFrPVCDayIntervalPktsDE1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of packets transmitted with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCDayIntervalEntry 16 }
|
|
|
|
adGenFrPVCDayIntervalOctetsDE1In OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets received with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCDayIntervalEntry 17 }
|
|
|
|
adGenFrPVCDayIntervalOctetsDE1Out OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The number of octets transmitted with the Discard Eligible
|
|
bit set to 1."
|
|
::= { adGenFrPVCDayIntervalEntry 18 }
|
|
|
|
-- ******************************************************************
|
|
-- The Frame Relay Slot Specific Table
|
|
-- ******************************************************************
|
|
|
|
adGenFrSlotTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdGenFrSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table provides frame relay group/bearer channel
|
|
and PVC slot specific information."
|
|
::= { adGenFrSlot 1 }
|
|
|
|
adGenFrSlotEntry OBJECT-TYPE
|
|
SYNTAX AdGenFrSlotEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Slot specific Frame Relay Group information."
|
|
INDEX { adGenSlotInfoIndex }
|
|
::= { adGenFrSlotTable 1 }
|
|
|
|
AdGenFrSlotEntry ::= SEQUENCE {
|
|
adGenFrSlotGroupLastCreateError DisplayString,
|
|
adGenFrSlotPVCMaxNumber Unsigned32,
|
|
adGenFrSlotPVCCurrentNumber Unsigned32
|
|
}
|
|
|
|
adGenFrSlotGroupLastCreateError OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The reason for the last error that occurred while attempting to
|
|
create an entry in the Frame Relay Group Table (adGenFrGroupTable)
|
|
on a specific slot."
|
|
::= { adGenFrSlotEntry 1 }
|
|
|
|
adGenFrSlotPVCMaxNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Maximum number of allowed Frame Relay PVCs on this slot. Each access
|
|
module provides a pool of available PVC resources that may
|
|
be assigned to any Frame Relay Group."
|
|
::= { adGenFrSlotEntry 2 }
|
|
|
|
adGenFrSlotPVCCurrentNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "The current number of Frame Relay PVC resources currently in
|
|
use on this slot. Each access module provides a pool of available PVC
|
|
resources that may be assigned to any Frame Relay Group. This
|
|
object reports the number currently assigned to carry user data."
|
|
::= { adGenFrSlotEntry 3 }
|
|
|
|
-- ******************************************************************
|
|
-- Frame Relay Notifications
|
|
-- ******************************************************************
|
|
|
|
adGenFrGroupDownAlarmClr NOTIFICATION-TYPE
|
|
OBJECTS { adTrapInformSeqNum,
|
|
sysName,
|
|
ifIndex,
|
|
ifOperStatus,
|
|
adTAeSCUTrapAlarmLevel,
|
|
adGenFrGroupLmiStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A adGenFrGroupDownAlarm clear is sent when the local in-channel
|
|
signaling protocol indicates that it is in the active(2) state.
|
|
If Frame Relay signaling is disabled, then group LMI status is
|
|
based on the operStatus of the frame-relay group."
|
|
|
|
--#TYPE "Major - Frame Relay Group Down - Cleared"
|
|
--#SUMMARY "Frame Relay Group Down - Cleared"
|
|
--#SUMMARY "cleared at shelf: %s, slot: %d, interface: %d"
|
|
--#ARGUMENTS {1,2,3}
|
|
--#SEVERITY "MAJOR"
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenFrAlarms 1 }
|
|
|
|
adGenFrGroupDownAlarmAct NOTIFICATION-TYPE
|
|
OBJECTS { adTrapInformSeqNum,
|
|
sysName,
|
|
ifIndex,
|
|
ifOperStatus,
|
|
adTAeSCUTrapAlarmLevel,
|
|
adGenFrGroupLmiStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A adGenFrGroupDownAlarm active is sent when the local in-channel
|
|
signaling protocol indicates that it is in a state other than
|
|
active(2). If Frame Relay signaling is disabled, then group
|
|
LMI status is based on the operStatus of the frame-relay group."
|
|
|
|
--#TYPE "Major - Frame Relay Group Down - Active"
|
|
--#SUMMARY "Frame Relay Group Down - Active"
|
|
--#SUMMARY "cleared at shelf: %s, slot: %d, interface: %d"
|
|
--#ARGUMENTS {1,2,3,4}
|
|
--#SEVERITY "MAJOR"
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenFrAlarms 2 }
|
|
|
|
adGenFrDlciDownAlarmClr NOTIFICATION-TYPE
|
|
OBJECTS { adTrapInformSeqNum,
|
|
sysName,
|
|
adGenFrPVCIfIndex,
|
|
adGenFrPVCDLCIIndex,
|
|
adTAeSCUTrapAlarmLevel,
|
|
adGenFrPVCState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A adGenFrDlciDownAlarm clear is sent when data DLCI is in the
|
|
active(2) state and is capable of passing user traffic."
|
|
|
|
--#TYPE "Minor - Frame Relay DLCI Inactive - Cleared"
|
|
--#SUMMARY "Frame Relay DLCI Inactive - Cleared"
|
|
--#SUMMARY "cleared at shelf: %s, slot: %d, interface: %d, dlci: %u"
|
|
--#ARGUMENTS {1,2,3,4}
|
|
--#SEVERITY "MINOR"
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenFrAlarms 3 }
|
|
|
|
adGenFrDlciDownAlarmAct NOTIFICATION-TYPE
|
|
OBJECTS { adTrapInformSeqNum,
|
|
sysName,
|
|
adGenFrPVCIfIndex,
|
|
adGenFrPVCDLCIIndex,
|
|
adTAeSCUTrapAlarmLevel,
|
|
adGenFrPVCState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A adGenFrDlciDownAlarm clear is sent when data DLCI is in a
|
|
state other than active(2) and is incapable of passing user traffic."
|
|
|
|
--#TYPE "Minor - Frame Relay DLCI Down - Active"
|
|
--#SUMMARY "Frame Relay DLCI Down - Active"
|
|
--#SUMMARY "cleared at shelf: %s, slot: %d, interface: %d, dlci: %u"
|
|
--#ARGUMENTS {1,2,3,4}
|
|
--#SEVERITY "MINOR"
|
|
--#GENERIC 6
|
|
--#CATEGORY "Alarm Events"
|
|
--#SOURCE_ID "A"
|
|
--#TIMEINDEX 0
|
|
::= { adGenFrAlarms 4 }
|
|
END
|