ZYXEL-SESCOMMON-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, TimeTicks, Counter
FROM RFC1155-SMI
OBJECT-TYPE FROM RFC-1212
ifIndex,DisplayString FROM RFC1213-MIB
RowStatus FROM SNMPv2-TC
sesSeriesCommon FROM ZYXEL-MIB;
-- zyxel OBJECT IDENTIFIER ::= { enterprises 890 }
-- products OBJECT IDENTIFIER ::= { zyxel 1 }
-- accessSwitch OBJECT IDENTIFIER ::= { products 5 }
-- sesSeries OBJECT IDENTIFIER ::= { accessSwitch 5 }
-- sesSeriesCommon OBJECT IDENTIFIER ::= { sesSeries 1 }
sesLineStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SesLineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains the current status of SHDSL line.
These managed objects are supported by ZyXEL SDSL
access switches."
::= { sesSeriesCommon 1 }
sesLineStatusEntry OBJECT-TYPE
SYNTAX SesLineStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An zyxelLineStatusEntry containing the specific
status for a particular SHDSL interface."
INDEX { ifIndex }
::= { sesLineStatusTable 1 }
SesLineStatusEntry ::=
SEQUENCE {
sesLineUptime TimeTicks,
sesLineLinkDown Counter,
sesLineNMdefect Counter,
sesLineHECdefect Counter,
sesLineTxPackets Counter,
sesLineRxPackets Counter,
sesLineTxFrames Counter,
sesLineRxFrames Counter,
sesLineTxCells Counter,
sesLineRxCells Counter
}
sesLineUptime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time duration since the connection between STU-C
STU-R is last setup."
::= { sesLineStatusEntry 1 }
sesLineLinkDown OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of link down since the SAM-1008 was last
restarted."
::= { sesLineStatusEntry 2 }
sesLineNMdefect OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of noise margin defects"
::= { sesLineStatusEntry 3 }
sesLineHECdefect OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of HEC defects"
::= { sesLineStatusEntry 4 }
sesLineTxPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of line Tx packets"
::= { sesLineStatusEntry 5 }
sesLineRxPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of line Rx packets"
::= { sesLineStatusEntry 6 }
sesLineTxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of line Tx frames"
::= { sesLineStatusEntry 7 }
sesLineRxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of line Rx frames"
::= { sesLineStatusEntry 8 }
sesLineTxCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of line Tx cells"
::= { sesLineStatusEntry 9 }
sesLineRxCells OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Count of line Rx cells"
::= { sesLineStatusEntry 10 }
sesMaxNumOfProfiles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of SHDSL profiles which the system supports."
::= { sesSeriesCommon 2 }
sesLineConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF SesLineConfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table includes common attributes describing the SHDSL line."
::= { sesSeriesCommon 3 }
sesLineConfEntry OBJECT-TYPE
SYNTAX SesLineConfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION "An entry in sesLineConfTable."
INDEX { ifIndex }
::= { sesLineConfTable 1 }
SesLineConfEntry ::=
SEQUENCE {
sesLineConfEncap INTEGER,
sesLineConfVpi INTEGER,
sesLineConfVci INTEGER
}
sesLineConfEncap OBJECT-TYPE
SYNTAX INTEGER {
llc(1),
vc(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The encapsulation of the SHDSL line."
::= { sesLineConfEntry 1 }
sesLineConfVpi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The VPI of the SHDSL line."
::= { sesLineConfEntry 2 }
sesLineConfVci OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The VCI of the SHDSL line."
::= { sesLineConfEntry 3 }
-- Port Bonding Talbe
sesMaxNumOfPortBondings OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of port bondings which the system supports."
::= { sesSeriesCommon 4 }
sesPortBondingTable OBJECT-TYPE
SYNTAX SEQUENCE OF SesPortBondingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table includes the configuration of port bonding."
::= { sesSeriesCommon 5 }
sesPortBondingEntry OBJECT-TYPE
SYNTAX SesPortBondingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in sesPortBondingTable."
INDEX { IMPLIED sesPortBondingName }
::= { sesPortBondingTable 1 }
SesPortBondingEntry ::=
SEQUENCE {
sesPortBondingName DisplayString,
sesPortBondingMemberList OCTET STRING,
sesPortBondingNumOfMembers INTEGER,
sesPortBondingMode INTEGER,
sesPortBondingRowStatus RowStatus
}
sesPortBondingName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This object is used by the port bonding table
in order to identify a row of this table."
::= { sesPortBondingEntry 1 }
sesPortBondingNumOfMembers OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of members included in the bonding entry."
::= { sesPortBondingEntry 2 }
sesPortBondingMemberList OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The member list is included in the bonding entry. Each member is
identified by two octets.
In the 2-wire mode, each member stands for a single port.
In the 4-wire mode, each member stands for a 4-wire group.
In the 8-wire mode, each member stands for a 8-wire group."
::= { sesPortBondingEntry 3 }
sesPortBondingMode OBJECT-TYPE
SYNTAX INTEGER {
twoWireC(1),
twoWireR(2),
fourWireC(3),
fourWireR(4),
eightWireC(5),
eightWireR(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The mode in which the bonding entry is.
twoWireC mode stands for 2-wire plus stu-c, and so on."
::= { sesPortBondingEntry 4 }
sesPortBondingRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To delete an existing row in this table."
::= { sesPortBondingEntry 5 }
-- N-Wire Bonding Table
sesNwireTable OBJECT-TYPE
SYNTAX SEQUENCE OF SesNwireEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table includes N-wire configurations."
::= { sesSeriesCommon 6 }
sesNwireEntry OBJECT-TYPE
SYNTAX SesNwireEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in sesNwireTable."
INDEX { IMPLIED sesNwireGroupName }
::= { sesNwireTable 1 }
SesNwireEntry ::=
SEQUENCE {
sesNwireGroupName DisplayString,
sesNwireGroupNumber OCTET STRING,
sesNwireMode INTEGER,
sesNwireRowStatus RowStatus
}
sesNwireGroupName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..32))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This object is used by the N-wire table
in order to identify a row of this table."
::= { sesNwireEntry 1 }
sesNwireGroupNumber OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The group number included in the N-wire entry. Each group is
identified by two octets.
In the 4-wire mode:
Group1 stands for Port1 and Port2
Group2 stands for Port3 and Port4
Group3 stands for Port5 and Port6
Group4 stands for Port7 and Port8
In the 8-wire mode:
Group1 stands for Port1, Port2, Port3 and Port4
Group2 stands for Port5, Port6, Port7 and Port8"
::= { sesNwireEntry 2 }
sesNwireMode OBJECT-TYPE
SYNTAX INTEGER {
fourWireC(1),
fourWireR(2),
eightWireC(3),
eightWireR(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The mode in which the N-wire entry is.
fourWireC mode stands for 4-wire plus stu-c, and so on."
::= { sesNwireEntry 3 }
sesNwireRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To delete an existing row in this table."
::= { sesNwireEntry 4 }