Observium_CE/mibs/zte/ZTE-AN-ETH-EFM-MIB

1298 lines
74 KiB
Plaintext

-- *****************************************************************
-- ZTE AN ETHERNET EFM MIB
--
-- 10-16-2008
--
-- Copyright(c) 2007 ZTE Corporation
-- All rights reserved.
-- *****************************************************************
ZTE-AN-ETH-EFM-MIB DEFINITIONS ::= BEGIN
IMPORTS
TruthValue FROM SNMPv2-TC
Unsigned32 FROM SNMPv2-SMI
Integer32 FROM SNMPv2-SMI
Counter32 FROM SNMPv2-SMI
MacAddress FROM SNMPv2-TC
TEXTUAL-CONVENTION FROM SNMPv2-TC
TimeStamp FROM SNMPv2-TC
OBJECT-TYPE FROM SNMPv2-SMI
ifIndex FROM RFC1213-MIB
CounterBasedGauge64 FROM HCNUM-TC
zxAn FROM ZTE-AN-TC-MIB
DisplayString FROM SNMPv2-TC;
zxAnEthOamObjects OBJECT IDENTIFIER ::={zxAn 61}
Dot3Oui ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"24-bit Organizationally Unique Identifier. Information on
OUIs can be found in IEEE 802-2001 [802-2001] Clause 9."
SYNTAX OCTET STRING(SIZE(3))
------------------------------------------------------------------------------
-- zxAnEthOamObjects
------------------------------------------------------------------------------
zxAnEthOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnEthOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains the primary controls and status for the OAM
capabilities of an Ethernet like interface. There will be one row
in this table for each Ethernet like interface in the system that
supports the OAM functions defined in [802.3ah]."
::= { zxAnEthOamObjects 1 }
zxAnEthOamEntry OBJECT-TYPE
SYNTAX ZxAnEthOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information on the Ethernet OAM
function for a single Ethernet like interface. Entries in the table
are created automatically for each interface supporting Ethernet OAM.
The status of the row entry can be determined from OamOperStatus.
A OamEntry is indexed in the OamTable by the ifIndex object
of the Interfaces MIB. "
INDEX { ifIndex }
::= { zxAnEthOamTable 1}
ZxAnEthOamEntry ::=
SEQUENCE {
zxAnEthOamAdminState INTEGER,
zxAnEthOamOperStatus INTEGER,
zxAnEthOamMode INTEGER,
zxAnEthOamMaxOamPduSize Unsigned32,
zxAnEthOamConfigRevision Unsigned32,
zxAnEthOamFunctionsSupported BITS,
zxAnEthOamHardwareInfo DisplayString,
zxAnEthOamSoftwareInfo DisplayString
}
zxAnEthOamAdminState OBJECT-TYPE
SYNTAX INTEGER{
enabled(1),
disabled(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to provision the default administrative OAM mode for
this interface. This object represents the desired state of OAM for this
interface. The OamAdminState always starts in the disabled(1) state
until an explicit management action or configuration information retained
by the system causes a transition to the enabled(1) state. When enabled(1),
Ethernet OAM will attempt to operate over this interface."
::= { zxAnEthOamEntry 1 }
zxAnEthOamOperStatus OBJECT-TYPE
SYNTAX INTEGER{
disabled(1),
linkFault(2),
passiveWait(3),
activeSendLocal(4),
sendLocalAndRemote(5),
sendLocalAndRemoteOk(6),
oamPeeringLocallyRejected(7),
oamPeeringRemotelyRejected(8),
operational(9),
nonOperHalfDuplex(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"At initialization and failure conditions, two OAM entities on the same full-duplex
Ethernet link begin a discovery phase to determine what OAM capabilities may be
used on that link. The progress of this initialization is controlled by the OAM
sublayer. This value is always disabled(1) if OAM is disabled on this interface
via the OamAdminState. If the link has detected a fault and is transmitting
OAMPDUs with a link fault indication, the value is linkFault(2). Also, if the
interface is not operational (ifOperStatus is not up(1)), linkFault(2) is returned.
Note that the object ifOperStatus may not be up(1) as a result of link failure or
administrative action (ifAdminState being down(2) or testing(3)). The passiveWait(3)
state is returned only by OAM entities in passive mode (OamMode) and reflects
the state in which the OAM entity is waiting to see if the peer device is OAM capable.
The activeSendLocal(4) value is used by active mode devices (OamMode) and reflects
the OAM entity actively trying to discover whether the peer has OAM capability but has
not yet made that determination. The state sendLocalAndRemote(5) reflects that the local
OAM entity has discovered the peer but has not yet accepted or rejected the configuration
of the peer. The local device can, for whatever reason, decide that the peer device is
unacceptable and decline OAM peering. If the local OAM entity rejects the peer OAM entity,
the state becomes oamPeeringLocallyRejected(7). If the OAM peering is allowed by the local
device, the state moves to sendLocalAndRemoteOk(6). Note that both the sendLocalAndRemote(5)
and oamPeeringLocallyRejected(7) states fall within the state SEND_LOCAL_REMOTE of the
Discovery state diagram [802.3ah, Figure 57-5], with the difference being whether the local
OAM client has actively rejected the peering or has just not indicated any decision yet.
Whether a peering decision has been made is indicated via the local flags field in the OAMPDU
(reflected in the aOAMLocalFlagsField of 30.3.6.1.10). If the remote OAM entity rejects the
peering, the state becomes oamPeeringRemotelyRejected(8). Note that both the sendLocalAndRemoteOk(6)
and oamPeeringRemotelyRejected(8) states fall within the state SEND_LOCAL_REMOTE_OK of the
Discovery state diagram [802.3ah, Figure 57-5], with the difference being whether the remote
OAM client has rejected the peering or has just not yet decided. This is indicated via the
remote flags field in the OAM PDU (reflected in the aOAMRemoteFlagsField of 30.3.6.1.11).
When the local OAM entity learns that both it and the remote OAM entity have accepted the
peering, the state moves to operational(9) corresponding to the SEND_ANY state of the
Discovery state diagram [802.3ah, Figure 57-5]. Since Ethernet OAM functions are not
designed to work completely over half-duplex interfaces, the value nonOperHalfDuplex(10)
is returned whenever Ethernet OAM is enabled (OamAdminState is enabled(1)) but the
interface is in half-duplex operation."
::= { zxAnEthOamEntry 2 }
zxAnEthOamMode OBJECT-TYPE
SYNTAX INTEGER{
passive(1),
active(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the mode of OAM operation for this Ethernet like interface.
OAM on Ethernet interfaces may be in 'active' mode or 'passive' mode. These two modes
differ in that active mode provides additional capabilities to initiate monitoring
activities with the remote OAM peer entity, while passive mode generally waits for
the peer to initiate OAM actions with it. As an example, an active OAM entity can
put the remote OAM entity in a loopback state, where a passive OAM entity cannot.
The default value of OamMode is dependent on the type of system on which this
Ethernet like interface resides. The default value should be 'active(2)' unless it
is known that this system should take on a subservient role to the other device
connected over this interface. Changing this value results in incrementing the
configuration revision field of locally generated OAMPDUs (30.3.6.1.12) and
potentially re-doing the OAM discovery process if the OamOperStatus was already
operational(9)."
::= { zxAnEthOamEntry 3 }
zxAnEthOamMaxOamPduSize OBJECT-TYPE
SYNTAX Unsigned32 (64..1518)
UNITS "octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The largest OAMPDU that the OAM entity supports. OAM entities exchange maximum
OAMPDU sizes and negotiate to use the smaller of the two maximum OAMPDU sizes
between the peers. This value is determined by the local implementation. "
::= { zxAnEthOamEntry 4 }
zxAnEthOamConfigRevision OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS "octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configuration revision of the OAM entity as reflected in the latest OAMPDU
sent by the OAM entity. The config revision is used by OAM entities to indicate
configuration changes have occurred which might require the peer OAM entity to
re-evaluate whether OAM peering is allowed. "
::= { zxAnEthOamEntry 5 }
zxAnEthOamFunctionsSupported OBJECT-TYPE
SYNTAX BITS{
unidirectionalSupport (0),
loopbackSupport(1),
eventSupport(2),
variableSupport(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM functions supported on this Ethernet like interface. OAM consists of
separate functional sets beyond the basic discovery process which is always required.
These functional groups can be supported independently by any implementation. These
values are communicated to the peer via the local configuration field of Information
OAMPDUs. Setting 'unidirectionalSupport(0)' indicates that the OAM entity supports
the transmission of OAMPDUs on links that are operating in undirectional mode
(traffic flowing in one direction only). Setting 'loopbackSupport(1)' indicates
the OAM entity can initiate and respond to loopback commands. Setting 'eventSupport(2)'
indicates the OAM entity can send and receive Event Notification OAMPDUs. Setting
'variableSupport(3)' indicates the OAM entity can send and receive Variable Request
and Response OAMPDUs. "
::= { zxAnEthOamEntry 6 }
zxAnEthOamHardwareInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of hardware info."
DEFVAL { "Hardware Info" }
::= { zxAnEthOamEntry 7 }
zxAnEthOamSoftwareInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual description of software info."
DEFVAL { "Software Info" }
::= { zxAnEthOamEntry 8 }
zxAnEthOamPeerTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnEthOamPeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains information about the OAM peer for a particular Ethernet
like interface. OAM entities communicate with a single OAM peer entity on
Ethernet links on which OAM is enabled and operating properly. There is one
entry in this table for each entry in the OamTable for which information
on the peer OAM entity is available."
::= { zxAnEthOamObjects 2 }
zxAnEthOamPeerEntry OBJECT-TYPE
SYNTAX ZxAnEthOamPeerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information on the peer OAM entity for
a single Ethernet like interface. Note that there is at most one OAM peer
for each Ethernet like interface. Entries are automatically created when
information about the OAM peer entity becomes available, and automatically
deleted when the OAM peer entity is no longer in communication. Peer
information is not available when OamOperStatus is disabled(1),
linkFault(2), passiveWait(3), activeSendLocal(4). or nonOperHalfDuplex(10))."
INDEX { ifIndex }
::= { zxAnEthOamPeerTable 1}
ZxAnEthOamPeerEntry ::=
SEQUENCE {
zxAnEthOamPeerMacAddress MacAddress,
zxAnEthOamPeerVendorOui Dot3Oui,
zxAnEthOamPeerVendorInfo Unsigned32,
zxAnEthOamPeerMode INTEGER,
zxAnEthOamPeerMaxOamPduSize Unsigned32,
zxAnEthOamPeerConfigRevision Unsigned32,
zxAnEthOamPeerFunctionsSupported BITS
}
zxAnEthOamPeerMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAC address of the peer OAM entity. The MAC address is derived from
the most recently received OAMPDU."
::= { zxAnEthOamPeerEntry 1 }
zxAnEthOamPeerVendorOui OBJECT-TYPE
SYNTAX Dot3Oui
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OUI of the OAM peer as reflected in the latest Information OAMPDU
received with a Local Information TLV. The OUI can be used to identify
the vendor of the remote OAM entity. This value is initialized to three
octets of zero before any Local Information TLV is received."
::= { zxAnEthOamPeerEntry 2 }
zxAnEthOamPeerVendorInfo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Vendor Info of the OAM peer as reflected in the latest Information
OAMPDU received with a Local Information TLV. The vendor information field
is within the Local Information TLV, and can be used to determine additional
information about the peer entity. The format of the vendor information is
unspecified within the 32-bit field. This value is initialized to zero before
any Local Information TLV is received."
::= { zxAnEthOamPeerEntry 3 }
zxAnEthOamPeerMode OBJECT-TYPE
SYNTAX INTEGER{
passive(1),
active(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The mode of the OAM peer as reflected in the latest Information OAMPDU received
with a Local Information TLV. The mode of the peer can be determined from the
Configuration field in the Local Information TLV of the last Information OAMPDU
received from the peer. The value is unknown(3) whenever no Local Information
TLV has been received. The values of active(2) and passive(1) are returned when
a Local Information TLV has been received indicating the peer is in active or
passive mode, respectively."
::= { zxAnEthOamPeerEntry 4 }
zxAnEthOamPeerMaxOamPduSize OBJECT-TYPE
SYNTAX Unsigned32 (0 | 64..1518)
UNITS "octets"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum size of OAMPDU supported by the peer as reflected in the latest
Information OAMPDU received with a Local Information TLV. Ethernet OAM on
this interface must not use OAMPDUs that exceed this size. The maximum OAMPDU
size can be determined from the PDU Configuration field of the Local Information
TLV of the last Information OAMPDU received from the peer. A value of zero is
returned if no Local Information TLV has been received. Otherwise, the value of
the OAM peer's maximum OAMPDU size is returned in this value."
::= { zxAnEthOamPeerEntry 5 }
zxAnEthOamPeerConfigRevision OBJECT-TYPE
SYNTAX Unsigned32(0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The configuration revision of the OAM peer as reflected in the latest OAMPDU.
This attribute is changed by the peer whenever it has a local configuration change
for Ethernet OAM this interface. The configuration revision can be determined from
the Revision field of the Local Information TLV of the most recently received
Information OAMPDU with a Local Information TLV. A value of zero is returned if
no Local Information TLV has been received."
::= { zxAnEthOamPeerEntry 6 }
zxAnEthOamPeerFunctionsSupported OBJECT-TYPE
SYNTAX BITS{
unidirectionalSupport(0),
loopbackSupport(1),
eventSupport(2),
variableSupport(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM functions supported on this Ethernet like interface. OAM consists of
separate functionality sets above the basic discovery process. This value
indicates the capabilities of the peer OAM entity with respect to these functions.
This value is initialized so all bits are clear. If unidirectionalSupport(0) is
set, then the peer OAM entity supports sending OAM frames on Ethernet interfaces
when the receive path is known to be inoperable. If loopbackSupport(1) is set,
then the peer OAM entity can send and receive OAM loopback commands. If eventSupport(2)
is set, then the peer OAM entity can send and receive event OAMPDUs to signal various
error conditions. If variableSupport(3) is set, then the peer OAM entity can send and
receive variable requests to monitor attribute value as described in Clause 57 of [802.3ah].
The capabilities of the OAM peer can be determined from the configuration field of
the Local Information TLV of the most recently received Information OAMPDU with a Local
Information TLV. All zeros are returned if no Local Information TLV has yet been received."
::= { zxAnEthOamPeerEntry 7 }
zxAnEthOamLoopbackTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnEthOamLoopbackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains controls for the loopback state of the local link as well
as indicating the status of the loopback function. There is one entry in this
table for each entry in OamTable that supports loopback functionality
(where OamFunctionsSupported includes the loopbackSupport bit set).
Loopback can be used to place the remote OAM entity in a state where every
received frame (except OAMPDUs) are echoed back over the same interface
on which they were received. In this state, at the remote entity, 'normal'
traffic is disabled as only the looped back frames are transmitted on
the interface. Loopback is thus an intrusive operation that prohibits normal
data flow and should be used accordingly. "
::= { zxAnEthOamObjects 3 }
zxAnEthOamLoopbackEntry OBJECT-TYPE
SYNTAX ZxAnEthOamLoopbackEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing information on the peer OAM entity for
a single Ethernet like interface. Note that there is at most one OAM peer
for each Ethernet like interface. Entries are automatically created when
information about the OAM peer entity becomes available, and automatically
deleted when the OAM peer entity is no longer in communication. Peer
information is not available when OamOperStatus is disabled(1),
linkFault(2), passiveWait(3), activeSendLocal(4). or nonOperHalfDuplex(10))."
INDEX { ifIndex }
::= { zxAnEthOamLoopbackTable 1}
ZxAnEthOamLoopbackEntry ::=
SEQUENCE {
zxAnEthOamLoopbackStatus INTEGER,
zxAnEthOamLoopbackIgnoreRx INTEGER,
zxAnEthOamLoopbackResult INTEGER,
zxAnEthOamLoopbackSend Integer32,
zxAnEthOamLoopbackRecv Integer32
}
zxAnEthOamLoopbackStatus OBJECT-TYPE
SYNTAX INTEGER{
-- all values, except where noted, can be read
-- but cannot be written
noLoopback (1),
-- initiatingLoopback can be read or written
initiatingLoopback (2),
remoteLoopback (3),
-- terminatingLoopback can be read or written
terminatingLoopback (4),
localLoopback (5),
unknown (6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The loopback status of the OAM entity. This status is determined by
a combination of the local parser and multiplexer states, the remote
parser and multiplexer states, as well as by the actions of the local
OAM client. When operating in normal mode with no loopback in progress,
the status reads noLoopback(1). The values initiatingLooopback(2) and
terminatingLoopback(4) can be read or written. The other values can only
be read - they can never be written. Writing initiatingLoopback causes the
local OAM entity to start the loopback process with its peer. This value
can only be written when the status is noLoopback(1). Writing the value
initiatingLoopback(2) in any other state has no effect. When in remoteLoopback(3),
writing terminatingLoopback(4) causes the local OAM entity to initiate the
termination of the loopback state. Writing terminatingLoopack(4) in any other
state has no effect. If the OAM client initiates a looopback and has sent an
Loopback OAMPDU and is waiting for a response, where the local parser and
multiplexer states are DISCARD (see [802.3ah, 57.2.11.1]), the status is
'initiatingLoopback'. In this case, the local OAM entity has yet to receive any
acknowledgement that the remote OAM entity has received its loopback command
request. If the local OAM client knows that the remote OAM entity is in loopback
mode (via the remote state information as described in [802.3ah, 57.2.11.1, 30.3.6.1.15]),
the status is remoteLoopback(3). If the local OAM client is in the process of
terminating the remote loopback [802.3ah, 57.2.11.3, 30.3.6.1.14], with its local
multiplexer and parser states in DISCARD, the status is terminatingLoopback(4). If
the remote OAM client has put the local OAM entity in loopback mode as indicated by
its local parser state, the status is localLoopback(5). The unknown(6) status indicates
the parser and multiplexer combination is unexpected. This status may be returned if
the OAM loopback is in a transition state but should not persist."
::= { zxAnEthOamLoopbackEntry 1 }
zxAnEthOamLoopbackIgnoreRx OBJECT-TYPE
SYNTAX INTEGER{
ignore(1),
process(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Since OAM loopback is a distruptive operation (user traffic does not pass), this
attribute provides a mechanism to provide controls over whether received OAM loopback
commands are processed or ignored. When the value is ignore(1), received loopback commands
are ignored. When the value is process(2), OAM loopback commands are processed. The default
value is to ignore loopback commands (ignore(1))."
::= { zxAnEthOamLoopbackEntry 2 }
zxAnEthOamLoopbackResult OBJECT-TYPE
SYNTAX INTEGER {
noResult(0),
success(1),
generalFailed(2), -- Test failed but no detailed reason.
noSupport(3), -- Current card doesn't support this test.
unkown(4), -- Unkown the test result.
noSuchPort(5), -- No this port on card
loopBackFailed(6),-- Loop back failed on card
portNotActive(7), -- Some test can't be excuted when port is not actived.
portInTesting(8), -- Port in testing and can't excute the new test
portInService(9), -- Port in service and can't excute the test
portFailures(10), -- Port has failures and can't excute the test
cardFailures(11), -- Card has failures and can't excute the test
noPvcFound(12), -- No PVC found on the test port
unknownTestType(13) -- The test type is not UTOPIA,AFE,HYBRID,ATUC-OAM or ATUR-OAM
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is loop test result and includes reasons for test failures."
::= { zxAnEthOamLoopbackEntry 3 }
zxAnEthOamLoopbackSend OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The count of packet will be sent in the loopback test."
::= { zxAnEthOamLoopbackEntry 4 }
zxAnEthOamLoopbackRecv OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The count of recived packet in the loopback test."
::= { zxAnEthOamLoopbackEntry 5 }
zxAnEthOamStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnEthOamStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains statistics for the OAM function on a particular Ethernet
like interface. There is an entry in the table for every entry in the OamTable.
The counters in this table are defined as 32-bit entries to match the counter size
as defined in [802.3ah]. Given the OAM protocol is a slow protocol, the counters
increment at a slow rate."
::= { zxAnEthOamObjects 4 }
zxAnEthOamStatsEntry OBJECT-TYPE
SYNTAX ZxAnEthOamStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table, containing statistics information on the Ethernet OAM
function for a single Ethernet like interface. Entries are automatically created
for every entry in the OamTable. Counters are maintained across transitions
in OamOperStatus."
INDEX { ifIndex }
::= { zxAnEthOamStatsTable 1}
ZxAnEthOamStatsEntry ::=
SEQUENCE {
zxAnEthOamInformationTx Counter32,
zxAnEthOamInformationRx Counter32,
zxAnEthOamUniqueEventNotificationTx Counter32,
zxAnEthOamUniqueEventNotificationRx Counter32,
zxAnEthOamDuplicateEventNotificationTx Counter32,
zxAnEthOamDuplicateEventNotificationRx Counter32,
zxAnEthOamLoopbackControlTx Counter32,
zxAnEthOamLoopbackControlRx Counter32,
zxAnEthOamVariableRequestTx Counter32,
zxAnEthOamVariableRequestRx Counter32,
zxAnEthOamVariableResponseTx Counter32,
zxAnEthOamVariableResponseRx Counter32,
zxAnEthOamOrgSpecificTx Counter32,
zxAnEthOamOrgSpecificRx Counter32,
zxAnEthOamUnsupportedCodesTx Counter32,
zxAnEthOamUnsupportedCodesRx Counter32,
zxAnEthOamFramesLostDueToOam Counter32
}
zxAnEthOamInformationTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Information OAMPDUs transmitted on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the
ifCounterDiscontinuityTime. "
::= { zxAnEthOamStatsEntry 1 }
zxAnEthOamInformationRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Information OAMPDUs received on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the
ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 2 }
zxAnEthOamUniqueEventNotificationTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of unique Event OAMPDUs transmitted on this interface.
Event notifications may be sent in duplicate to increase the probability of
successfully being received, given the possiblity that a frame may be lost
in transit. Duplicate Event Notification transmissions are counted by
OamDuplicateEventNotificationTx. A unique Event Notification OAMPDU is
indicated as an Event Notification OAMPDU with a Sequence Number field that
is distinct from the previously transmitted Event Notification OAMPDU Sequence
Number. Discontinuities of this counter can occur at re-initialization of the
management system, and at other times as indicated by the value of the
ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 3 }
zxAnEthOamUniqueEventNotificationRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of unique Event OAMPDUs received on this interface.
Event notification OAMPDUs may be sent in duplicate to increase the probability
of successfully being received, given the possiblity that a frame may be lost
in transit. Duplicate Event Notification receptions are counted by
OamDuplicateEventNotificationRx. A unique Event Notification OAMPDU is
indicated as an Event Notification OAMPDU with a Sequence Number field that is
distinct from the previously received Event Notification OAMPDU Sequence Number.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 4 }
zxAnEthOamDuplicateEventNotificationTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of duplicate Event OAMPDUs transmitted on this interface.
Event notification OAMPDUs may be sent in duplicate to increase the probability
of successfully being received, given the possiblity that a frame may be lost in
transit. A duplicate Event Notification OAMPDU is indicated as an Event Notification
OAMPDU with a Sequence Number field that is identical to the previously transmitted
Event Notification OAMPDU Sequence Number. Discontinuities of this counter can occur
at re-initialization of the management system, and at other times as indicated by the
value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 5 }
zxAnEthOamDuplicateEventNotificationRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of duplicate Event OAMPDUs received on this interface.
Event notification OAMPDUs may be sent in duplicate to increase the probability of
successfully being received, given the possibility that a frame may be lost in transit.
A duplicate Event Notification OAMPDU is indicated as an Event Notification OAMPDU
with a Sequence Number field that is identical to the previously received Event
Notification OAMPDU Sequence Number. Discontinuities of this counter can occur at
re-initialization of the management system, and at other times as indicated by the
value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 6 }
zxAnEthOamLoopbackControlTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Loopback Control OAMPDUs transmitted on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 7 }
zxAnEthOamLoopbackControlRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Loopback Control OAMPDUs received on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 8 }
zxAnEthOamVariableRequestTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Variable Request OAMPDUs transmitted on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 9 }
zxAnEthOamVariableRequestRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Variable Request OAMPDUs received on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 10 }
zxAnEthOamVariableResponseTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Variable Response OAMPDUs transmitted on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 11 }
zxAnEthOamVariableResponseRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Variable Response OAMPDUs received on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 12 }
zxAnEthOamOrgSpecificTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Organization Specific OAMPDUs transmitted on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 13 }
zxAnEthOamOrgSpecificRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of Organization Specific OAMPDUs received on this interface.
Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 14 }
zxAnEthOamUnsupportedCodesTx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of OAMPDUs transmitted on this interface with an unsupported
op-code. Discontinuities of this counter can occur at re-initialization of the management
system, and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 15 }
zxAnEthOamUnsupportedCodesRx OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of OAMPDUs received on this interface with an unsupported op-code.
Discontinuities of this counter can occur at re-initialization of the management system,
and at other times as indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 16 }
zxAnEthOamFramesLostDueToOam OBJECT-TYPE
SYNTAX Counter32
UNITS "frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A count of the number of frames that were dropped by the OAM multiplexer. Since the
OAM mulitplexer has multiple inputs and a single output, there may be cases where
frames are dropped due to transmit resource contention. This counter is incremented
whenever a frame is dropped by the OAM layer. Note that any Ethernet frame, not just
OAMPDUs, may be dropped by the OAM layer. This can occur when an OAMPDU takes precedence
over a 'normal' frame resulting in the 'normal' frame being dropped. When this counter
is incremented, no other counters in this MIB are incremented. Discontinuities of this
counter can occur at re-initialization of the management system, and at other times as
indicated by the value of the ifCounterDiscontinuityTime."
::= { zxAnEthOamStatsEntry 17 }
zxAnEthOamEventConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnEthOamEventConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Ethernet OAM includes the ability to generate and receive Event Notification OAMPDUs
to indicate various link problems. This table contains the mechanisms to enable
Event Notifications and configure the thresholds to generate the standard Ethernet
OAM events. There is one entry in the table for every entry in OamTable that
supports OAM events (where OamFunctionsSupported includes the eventSupport bit set).
The values in the table are maintained across changes to OamOperStatus. There
are other events (dying gasp, critical events) that are not threshold crossing
events but which can be enabled/disabled via this table."
::= { zxAnEthOamObjects 5 }
zxAnEthOamEventConfigEntry OBJECT-TYPE
SYNTAX ZxAnEthOamEventConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries are automatically created and deleted from this table, and exist
whenever the OAM entity supports Ethernet OAM events (as indicated by the
eventSupport bit in OamFunctionsSuppported). Values in the table are
maintained across changes to the value of OamOperStatus. Event configuration
controls when the local management entity sends Event Notification OAMPDUs
to its OAM peer, and when certain event flags are set or cleared in OAMPDUs."
INDEX { ifIndex }
::= { zxAnEthOamEventConfigTable 1}
ZxAnEthOamEventConfigEntry ::=
SEQUENCE {
zxAnEthOamErrSymPeriodWindowHi Unsigned32,
zxAnEthOamErrSymPeriodWindowLo Unsigned32,
zxAnEthOamErrSymPeriodThresholdHi Unsigned32,
zxAnEthOamErrSymPeriodThresholdLo Unsigned32,
zxAnEthOamErrSymPeriodEvNotifEnable TruthValue,
zxAnEthOamErrFramePeriodWindow Unsigned32,
zxAnEthOamErrFramePeriodThreshold Unsigned32,
zxAnEthOamErrFramePeriodEvNotifEnable TruthValue,
zxAnEthOamErrFrameWindow Unsigned32,
zxAnEthOamErrFrameThreshold Unsigned32,
zxAnEthOamErrFrameEvNotifEnable TruthValue,
zxAnEthOamErrFrameSecsSummaryWindow Integer32,
zxAnEthOamErrFrameSecsSummaryThreshold Integer32,
zxAnEthOamErrFrameSecsEvNotifEnable TruthValue,
zxAnEthOamDyingGaspEnable TruthValue,
zxAnEthOamCriticalEventEnable TruthValue
}
zxAnEthOamErrSymPeriodWindowHi OBJECT-TYPE
SYNTAX Unsigned32
UNITS "2^32 symbols"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The two objects OamErrSymPeriodWindowHi and OamErrSymPeriodLo
together form an unsigned 64-bit integer representing the number of
symbols over which this threshold event is defined. This is defined as
OamErrSymPeriodWindow = ((2^32)*OamErrSymPeriodWindowHi) +
OamErrSymPeriodWindowLo If OamErrSymPeriodThreshold symbol
errors occur within a window of OamErrSymPeriodWindow symbols, an
Event Notification OAMPDU should be generated with an Errored Symbol
Period Event TLV indicating the threshold has been crossed in this window.
The default value for OamErrSymPeriodWindow is the number of symbols
in one second for the underlying physical layer."
::= { zxAnEthOamEventConfigEntry 1 }
zxAnEthOamErrSymPeriodWindowLo OBJECT-TYPE
SYNTAX Unsigned32
UNITS "symbols"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The two objects OamErrSymPeriodWindowHi and OamErrSymPeriodWindowLo
together form an unsigned 64-bit integer representing the number of symbols
over which this threshold event is defined. This is defined as OamErrSymPeriodWindow
= ((2^32)*OamErrSymPeriodWindowHi) + OamErrSymPeriodWindowLo If
OamErrSymPeriodThreshold symbol errors occur within a window of
OamErrSymPeriodWindow symbols, an Event Notification OAMPDU should be
generated with an Errored Symbol Period Event TLV indicating the threshold
has been crossed in this window. The default value for OamErrSymPeriodWindow
is the number of symbols in one second for the underlying physical layer."
::= { zxAnEthOamEventConfigEntry 2 }
zxAnEthOamErrSymPeriodThresholdHi OBJECT-TYPE
SYNTAX Unsigned32
UNITS "2^32 symbols"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The two objects OamErrSymPeriodThresholdHi and OamErrSymPeriodThresholdLo
together form an unsigned 64-bit integer representing the number of symbol errors
that must occur within a given window to cause this event. This is defined as
OamErrSymPeriodThreshold = ((2^32) * OamErrSymPeriodThresholdHi) +
OamErrSymPeriodThresholdLo If OamErrSymPeriodThreshold symbol errors
occur within a window of OamErrSymPeriodWindow symbols, an Event Notification
OAMPDU should be generated with an Errored Symbol Period Event TLV indicating the
threshold has been crossed in this window. The default value for
OamErrSymPeriodThreshold is one symbol errors. If the threshold value is zero,
then an Event Notification OAMPDU is sent periodically (at the end of every window).
This can be used as an asynchronous notification to the peer OAM entity of the
statistics related to this threshold crossing alarm."
::= { zxAnEthOamEventConfigEntry 3}
zxAnEthOamErrSymPeriodThresholdLo OBJECT-TYPE
SYNTAX Unsigned32
UNITS "symbols"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The two objects OamErrSymPeriodThresholdHi and OamErrSymPeriodThresholdLo
together form an unsigned 64-bit integer representing the number of symbol errors
that must occur within a given window to cause this event. This is defined as
OamErrSymPeriodThreshold = ((2^32) * OamErrSymPeriodThresholdHi) +
OamErrSymPeriodThresholdLo If OamErrSymPeriodThreshold symbol errors occur
within a window of OamErrSymPeriodWindow symbols, an Event Notification OAMPDU
should be generated with an Errored Symbol Period Event TLV indicating the threshold
has been crossed in this window. The default value for OamErrSymPeriodThreshold
is one symbol error. If the threshold value is zero, then an Event Notification
OAMPDU is sent periodically (at the end of every window). This can be used as an
asynchronous notification to the peer OAM entity of the statistics related to this
threshold crossing alarm."
::= { zxAnEthOamEventConfigEntry 4}
zxAnEthOamErrSymPeriodEvNotifEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true, the OAM entity should send an Event Notification OAMPDU when an Errored
Symbol Period Event occurs. By default, this object should have the value true for
Ethernet like interfaces that support OAM. If the OAM layer does not support event
notifications (as indicated via the OamFunctionsSupported attribute), this
value is ignored."
::= { zxAnEthOamEventConfigEntry 5}
zxAnEthOamErrFramePeriodWindow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "frames"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of frames over which the threshold is defined. The default value of
the window is the number of minimum size Ethernet frames that can be received
over the physical layer in one second. If OamErrFramePeriodThreshold frame
errors occur within a window of OamErrFramePeriodWindow frames, an Event
Notification OAMPDU should be generated with an Errored Frame Period Event TLV
indicating the threshold has been crossed in this window."
::= { zxAnEthOamEventConfigEntry 6}
zxAnEthOamErrFramePeriodThreshold OBJECT-TYPE
SYNTAX Unsigned32
UNITS "frames"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of frame errors that must occur for this event to be triggered. The
default value is one frame error. If the threshold value is zero, then an Event
Notification OAMPDU is sent periodically (at the end of every window). This can
be used as an asynchronous notification to the peer OAM entity of the statistics
related to this threshold crossing alarm. If OamErrFramePeriodThreshold frame
errors occur within a window of OamErrFramePeriodWindow frames, an Event
Notification OAMPDU should be generated with an Errored Frame Period Event TLV
indicating the threshold has been crossed in this window."
::= { zxAnEthOamEventConfigEntry 7}
zxAnEthOamErrFramePeriodEvNotifEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true, the OAM entity should send an Event Notification OAMPDU when an Errored
Frame Period Event occurs. By default, this object should have the value true
for Ethernet like interfaces that support OAM. If the OAM layer does not support
event notifications (as indicated via the OamFunctionsSupported attribute),
this value is ignored."
::= { zxAnEthOamEventConfigEntry 8}
zxAnEthOamErrFrameWindow OBJECT-TYPE
SYNTAX Unsigned32
UNITS "tenths of a second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time (in 100ms increments) over which the threshold is defined.
The default value is 10 (1 second). If OamErrFrameThreshold frame errors occur
within a window of OamErrFrameWindow seconds (measured in tenths of seconds),
an Event Notification OAMPDU should be generated with an Errored Frame Event TLV
indicating the threshold has been crossed in this window."
::= { zxAnEthOamEventConfigEntry 9}
zxAnEthOamErrFrameThreshold OBJECT-TYPE
SYNTAX Unsigned32
UNITS "frames"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of frame errors that must occur for this event to be triggered. The
default value is one frame error. If the threshold value is zero, then an Event
Notification OAMPDU is sent periodically (at the end of every window). This can
be used as an asynchronous notification to the peer OAM entity of the statistics
related to this threshold crossing alarm. If OamErrFrameThreshold frame errors
occur within a window of OamErrFrameWindow (in tenths of seconds), an Event
Notification OAMPDU should be generated with an Errored Frame Event TLV indicating
the threshold has been crossed in this window."
::= { zxAnEthOamEventConfigEntry 10}
zxAnEthOamErrFrameEvNotifEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true, the OAM entity should send an Event Notification OAMPDU when an Errored
Frame Event occurs. By default, this object should have the value true for Ethernet
like interfaces that support OAM. If the OAM layer does not support event notifications
(as indicated via the OamFunctionsSupported attribute), this value is ignored."
::= { zxAnEthOamEventConfigEntry 11}
zxAnEthOamErrFrameSecsSummaryWindow OBJECT-TYPE
SYNTAX Integer32(100..9000)
UNITS "tenths of a second"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The amount of time (in 100ms intervals) over which the threshold is defined.
The default value is 100 (10 seconds). If OamErrFrameSecsSummaryThreshold
frame errors occur within a window of OamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated with an Errored Frame
Seconds Summary Event TLV indicating the threshold has been crossed in this window."
::= { zxAnEthOamEventConfigEntry 12}
zxAnEthOamErrFrameSecsSummaryThreshold OBJECT-TYPE
SYNTAX Integer32(1..900)
UNITS "errored frame seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of errored frame seconds that must occur for this event to be triggered.
The default value is one errored frame second. If the threshold value is zero, then
an Event Notification OAMPDU is sent periodically (at the end of every window).
This can be used as an asynchronous notification to the peer OAM entity of the
statistics related to this threshold crossing alarm. If OamErrFrameSecsSummaryThreshold
frame errors occur within a window of OamErrFrameSecsSummaryWindow (in tenths of
seconds), an Event Notification OAMPDU should be generated with an Errored Frame
Seconds Summary Event TLV indicating the threshold has been crossed in this window."
::= { zxAnEthOamEventConfigEntry 13}
zxAnEthOamErrFrameSecsEvNotifEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true, the local OAM entity should send an Event Notification OAMPDU when an
Errored Frame Seconds Event occurs. By default, this object should have the value
true for Ethernet like interfaces that support OAM. If the OAM layer does not support
event notifications (as indicated via the OamFunctionsSupported attribute),
this value is ignored."
::= { zxAnEthOamEventConfigEntry 14}
zxAnEthOamDyingGaspEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true, the local OAM entity should attempt to indicate a dying gasp via
the OAMPDU flags field to its peer OAM entity when a dying gasp event occurs.
The exact definition of a dying gasp event is implementation dependent. If
the system does not support dying gasp capability, setting this object has
no effect, and reading the object should always result in 'false'.By default,
this object should have the value true for Ethernet like interfaces that
support OAM. If the OAM layer does not support event notifications (as
indicated via the OamFunctionsSupported attribute), this value is ignored."
::= { zxAnEthOamEventConfigEntry 15}
zxAnEthOamCriticalEventEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If true, the local OAM entity should attempt to indicate a critical event
via the OAMPDU flags to its peer OAM entity when a critical event occurs.
The exact definition of a critical event is implementation dependent. If
the system does not support critical event capability, setting this object
has no effect, and reading the object should always result in 'false'. By
default, this object should have the value true for Ethernet like interfaces
that support OAM. If the OAM layer does not support event notifications (as
indicated via the OamFunctionsSupported attribute), this value is ignored."
::= { zxAnEthOamEventConfigEntry 16}
zxAnEthOamEventLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZxAnEthOamEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table records a history of the events that have occurred at the Ethernet
OAM level. These events can include locally detected events, which may result
in locally generated OAMPDUs, and remotely detected events, which are detected
by the OAM peer entity and signaled to the local entity via Ethernet OAM.
Ethernet OAM events can be signaled by Event Notification OAMPDUs or by the
flags field in any OAMPDU. This table contains both threshold crossing events
and non-threshold crossing events. The parameters for the threshold window,
threshold value, and actual value (OamEventLogWindowXX, OamEventLogThresholdXX,
OamEventLogValue) are only applicable to threshold crossing events, and
are returned as all F's (2^32 - 1) for non-threshold crossing events. Entries
in the table are automatically created when such events are detected. The size
of the table is implementation dependent. When the table reaches its maximum
size, older entries are automatically deleted to make room for newer entries."
::= { zxAnEthOamObjects 6 }
zxAnEthOamEventLogEntry OBJECT-TYPE
SYNTAX ZxAnEthOamEventLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the OamEventLogTable. Entries are automatically created whenever
Ethernet OAM events occur at the local OAM entity, and when Event Notification
OAMPDUs are received at the local OAM entity (indicating events have occurred at
the peer OAM entity). The size of the table is implementation dependent, but
when the table becomes full, older events are automatically deleted to make
room for newer events. The table index OamEventLogIndex increments for
each new entry, and when the maximum value is reached the value restarts at zero."
INDEX { ifIndex, zxAnEthOamEventLogIndex}
::= { zxAnEthOamEventLogTable 1}
ZxAnEthOamEventLogEntry ::=
SEQUENCE {
zxAnEthOamEventLogIndex Unsigned32,
zxAnEthOamEventLogTimestamp TimeStamp,
zxAnEthOamEventLogOui Dot3Oui,
zxAnEthOamEventLogType Unsigned32,
zxAnEthOamEventLogLocation INTEGER,
zxAnEthOamEventLogWindowHi Unsigned32,
zxAnEthOamEventLogWindowLo Unsigned32,
zxAnEthOamEventLogThresholdHi Unsigned32,
zxAnEthOamEventLogThresholdLo Unsigned32,
zxAnEthOamEventLogValue CounterBasedGauge64,
zxAnEthOamEventLogRunningTotal CounterBasedGauge64,
zxAnEthOamEventLogEventTotal Unsigned32
}
zxAnEthOamEventLogIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An arbitrary integer for identifiying individual events within the event log. "
::= { zxAnEthOamEventLogEntry 1 }
zxAnEthOamEventLogTimestamp OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime at the time of the logged event. For locally generated
events, the time of the event can be accurately retrieved from sysUpTime.
For remotely generated events, the time of the event is indicated by the
reception of the Event Notification OAMPDU indicating the event occurred on
the peer. A system may attempt to adjust the timestamp value to more accurately
reflect the time of the event at the peer OAM entity by using other information,
such as that found in the timestamp found of the Event Notification TLVs, which
provides an indication of the relative time between events at the peer entity. "
::= { zxAnEthOamEventLogEntry 2 }
zxAnEthOamEventLogOui OBJECT-TYPE
SYNTAX Dot3Oui
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OUI of the entity defining the object type. All IEEE 802.3 defined events
(as appearing in [802.3ah] except for the Organizationally Unique Event TLVs)
use the IEEE 802.3 OUI of 0x0180C2. Organizations defining their own Event
Notification TLVs include their OUI in the Event Notification TLV which gets
reflected here. "
::= { zxAnEthOamEventLogEntry 3 }
zxAnEthOamEventLogType OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of event that generated this entry in the event log. When the OUI is
the IEEE 802.3 OUI of 0x0180C2, the following event types are defined:
erroredSymbolEvent(1),
erroredFramePeriodEvent (2),
erroredFrameEvent(3),
erroredFrameSecondsEvent(4),
linkFault(256),
dyingGaspEvent(257),
criticalLinkEvent(258) The first four are considered threshold crossing events as
they are generated when a metric exceeds a given value within a specified window.
The other three are not threshold crossing events. When the OUI is not 71874
(0x0180C2 in hex), then some other organization has defined the event space. If
event subtyping is known to the implementation, it may be reflected here. Otherwise,
this value should return all F's (2^32 - 1)."
::= { zxAnEthOamEventLogEntry 4 }
zxAnEthOamEventLogLocation OBJECT-TYPE
SYNTAX INTEGER{
local(1),
remote(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Whether this event occurred locally (local(1)), or was received from the OAM peer
via Ethernet OAM (remote(2))."
::= { zxAnEthOamEventLogEntry 5 }
zxAnEthOamEventLogWindowHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, the two objects
OamEventWindowHi and OamEventWindowLo form an unsigned 64-bit
integer yielding the window over which the value was measured for the threshold
crossing event (for example, 5, when 11 occurrences happened in 5 seconds while
the threshold was 10). The two objects are combined as:
OamEventLogWindow = ((2^32) * OamEventLogWindowHi)
+ OamEventLogWindowLo
Otherwise, this value is returned as all F's (2^32 - 1) and adds no useful information."
::= { zxAnEthOamEventLogEntry 6 }
zxAnEthOamEventLogWindowLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, the two objects OamEventWindowHi
and OamEventWindowLo form an unsigned 64-bit integer yielding the window over which
the value was measured for the threshold crossing event (for example, 5, when 11
occurrences happened in 5 seconds while the threshold was 10). The two objects are combined as:
OamEventLogWindow = ((2^32) * OamEventLogWindowHi)
+ OamEventLogWindowLo
Otherwise, this value is returned as all F's (2^32 - 1) and adds no useful information."
::= { zxAnEthOamEventLogEntry 7 }
zxAnEthOamEventLogThresholdHi OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, the two objects OamEventThresholdHi
and OamEventThresholdLo form an unsigned 64-bit integer yielding the value that was
crossed for the threshold crossing event (for example, 10, when 11 occurrences happened in
5 seconds while the threshold was 10). The two objects are combined as:
OamEventLogThreshold = ((2^32) * OamEventLogThresholdHi)
+ OamEventLogThresholdLo
Otherwise, this value is returned as all F's (2^32 -1) and adds no useful information."
::= { zxAnEthOamEventLogEntry 8 }
zxAnEthOamEventLogThresholdLo OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, the two objects OamEventThresholdHi
and OamEventThresholdLo form an unsigned 64-bit integer yielding the value that was
crossed for the threshold crossing event (for example, 10, when 11 occurrences happened in
5 seconds while the threshold was 10). The two objects are combined as:
OamEventLogThreshold = ((2^32) * OamEventLogThresholdHi)
+ OamEventLogThresholdLo
Otherwise, this value is returned as all F's (2^32 - 1) and adds no useful information."
::= { zxAnEthOamEventLogEntry 9 }
zxAnEthOamEventLogValue OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If the event represents a threshold crossing event, this value indicates the value
of the parameter within the given window that generated this event (for example,
11, when 11 occurrences happened in 5 seconds while the threshold was 10). Otherwise,
this value is returned as all F's (2^64 - 1) and adds no useful information."
::= { zxAnEthOamEventLogEntry 10 }
zxAnEthOamEventLogRunningTotal OBJECT-TYPE
SYNTAX CounterBasedGauge64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each Event Notification TLV contains a running total of the number of times an
event has occurred, as well as the number of times an Event Notification for
the event has been transmitted. For non-threshold crossing events, the number
of events (OamLogRunningTotal) and the number of resultant Event Notifications
(OamLogEventTotal) should be identical. For threshold crossing events, since
multiple occurrences may be required to cross the threshold, these values are likely
different. This value represents the total number of times this event has happened
since the last reset (for example, 3253, when 3253 symbol errors have occurred
since the last reset, which has resulted in 51 symbol error threshold crossing
events since the last reset)."
::= { zxAnEthOamEventLogEntry 11 }
zxAnEthOamEventLogEventTotal OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each Event Notification TLV contains a running total of the number of times an
event has occurred, as well as the number of times an Event Notification for the
event has been transmitted. For non-threshold crossing events, the number of
events (OamLogRunningTotal) and the number of resultant Event Notifications
(OamLogEventTotal) should be identical. For threshold crossing events, since
multiple occurrences may be required to cross the threshold, these values are
likely different. This value represents the total number of times one or more of
these occurrences have resulted in an Event Notification (for example, 51 when 3253
symbol errors have occurred since the last reset, which has resulted in 51 symbol
error threshold crossing events since the last reset)."
::= { zxAnEthOamEventLogEntry 12 }
-- ******************************************************************
-- The GloPara Database
-- ******************************************************************
zxAnEthOamGlobalEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" "
REFERENCE
" "
::= { zxAnEthOamObjects 7 }
END