-- phyVaIf.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 3.0 Build 285
-- Monday, November 16, 2009 at 10:24:53
--
Zhone-VOICE-ANALOG-IF-MIB DEFINITIONS ::= BEGIN
IMPORTS
ifIndex, InterfaceIndex
FROM IF-MIB
Integer32, Counter32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
TruthValue
FROM SNMPv2-TC
zhonePhysical, zhoneModules
FROM Zhone
ZhoneRowStatus
FROM Zhone-TC;
--
--
--
-- --
--
-- --
-- --
-- --
--
--
--
--
--
--
--
--
--
-- 1.3.6.1.4.1.5504.6.13
zhoneVoiceAnalogIf-MIB MODULE-IDENTITY
LAST-UPDATED "200911171030Z" -- November 16, 2009 at 10:30 GMT
ORGANIZATION
"Zhone Technologies, Inc."
CONTACT-INFO
"Postal:
Zhone Technologies, Inc.
@Zhone Way
7001 Oakport
Oakland, Ca 94621
Toll-Free 877-ZHONE20 (+1 877-946-6320)
Tel: +1 510-777-7000
Fax: +1 510-777-7001
Email: support@zhone.com
"
DESCRIPTION
"Analog Voice Interface MIB module.
This MIB manages the E&M, FXO, FXS
Interfaces in the Zhone's product.
"
REVISION "200905050236Z" -- May 05, 2009 at 02:36 GMT
DESCRIPTION
"V01.00.10 - Added new field if-cfg-loop-current in table analog-if-cfg-profile"
REVISION "200803261745Z" -- March 26, 2008 at 17:45 GMT
DESCRIPTION
"Add ebs to zhoneValIfCfgLineType field."
REVISION "200711010230Z" -- November 01, 2007 at 02:30 GMT
DESCRIPTION
"V01.00.08 - Edited IfCfgImpedance field descriptions that ohmscomplex1 and ohmscomplex2 are Not Supported."
REVISION "200509061114Z" -- September 06, 2005 at 11:14 GMT
DESCRIPTION
"Deprecate zhonePotsRingTable. Move to zhoneVoiceRingTable in genVoiceStatMib."
REVISION "200508081500Z" -- August 08, 2005 at 15:00 GMT
DESCRIPTION
"Add zhonePotsRing table."
REVISION "200505111520Z" -- May 11, 2005 at 15:20 GMT
DESCRIPTION
"Changed zhoneVaIfCfgImpedance default value description from ohms900Complex to ohms600Complex."
REVISION "200505021722Z" -- May 02, 2005 at 17:22 GMT
DESCRIPTION
"Add default value descriptions for zhoneVAIfCfgImpedance, zhoneVAIffgReceivelp, zhoneVaIfCfgTransmitTlp."
REVISION "200410071134Z" -- October 07, 2004 at 11:34 GMT
DESCRIPTION
"zhoneVaIfEMCfgEntry
change SignalType, CfgOperation and DialType from read-write to read-only"
REVISION "200110101119Z" -- October 10, 2001 at 11:19 GMT
DESCRIPTION
"V01.00.02 - Removed Mark-Up for the zhoneVaIfFXSTimingDigitDuration and zhoneVaIfFXSTimingInterDigitDuration OIDs. Also added comment for the zhoneVaIfStatusSignalError OID."
REVISION "200102151852Z" -- February 15, 2001 at 18:52 GMT
DESCRIPTION
"V01.00.01 - Add DEFVAL for TruthValue types."
REVISION "200009121421Z" -- September 12, 2000 at 14:21 GMT
DESCRIPTION
"V01.00.00 - Initial Release"
::= { zhoneModules 13 }
--
--
-- Overview of Analog Voice interface MIB
--
-- The Analog Voice interface MIB provides the standard configuration,
-- timing parameters and telephony hook, ring status information on zhone's
-- Analog Voice interface implementation. The following groups
-- are managed:
-- 1) Analog interface general group
-- 2) E&M (recEive and transMit) interface group
-- 3) FXO (Foreign Exchange Office) interface group
-- 4) FXS (Foreign Exchange Station) interface group
--
-- ifEntry for an Analog Voice Interface
--
-- The ifEntry for an Analog Voice Interface supports the
-- ifGeneralInformationGroup of zhone IF-MIB.
--
-- ifTable Comments
-- ============== =====================================================
-- ifIndex Each Analog telephony interface is represented by an
-- ifEntry.
-- ifDescr Textual port description.
-- ifType The IANA value of voiceEM(100), voiceFXO(101) and
-- voiceFXS(102).
-- ifSpeed contains a zero value.
-- ifPhysAddress contains an octet string of zero length.
--
-- ifAdminStatus The desired administrative status of the
-- Analog Telephony interface port.
-- ifOperStatus The current operational status of the Analog Telephony
-- interface port. Note that dormant(5) is explicitly being
-- used as defined in RFC 1573.
-- ifLastChange Refer to RFC 1573.
-- ifLinkUpDownTrapEnable
-- Refer to RFC 1573.
-- ifConnectorPresent
-- Refer to RFC 1573.
-- ifHighSpeed contains a zero value.
-- ifName Refer to RFC 1573.
--
--
--
--
--
--
-- Node definitions
--
-- To Create Mib Handler file ( run in /vob/mibs/src):
-- /vob/EPILOGUE/binaries/emissary/solaris/mibcomp
-- rfc1907.mib iftype.mib rfc2233.mib Zhone.mib Zhone-TC.mib
-- -stub -o "MibHdlr.c"
-- 1.3.6.1.4.1.5504.5.6
zhoneVaIfObjects OBJECT IDENTIFIER ::= { zhonePhysical 6 }
-- 1.3.6.1.4.1.5504.5.6.1
zhoneVaIfGeneralObjects OBJECT IDENTIFIER ::= { zhoneVaIfObjects 1 }
-- ****************************************************************************
-- The Analog Voice General Interface Group
-- ****************************************************************************
-- [1] Analog Voice Interface Standard Configuration Table
-- [2] Analog Voice Interface Status Table
--
--
--
-- ****************************************************************************
-- The Analog Voice Interface Standard Configuration Table
-- ****************************************************************************
--
--
-- 1.3.6.1.4.1.5504.5.6.1.1
zhoneVaIfCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Analog Voice Standard Configuration Table. It contains
the standard configuration information of the analog
telephony interface.
"
::= { zhoneVaIfGeneralObjects 1 }
-- 1.3.6.1.4.1.5504.5.6.1.1.1
zhoneVaIfCfgEntry OBJECT-TYPE
SYNTAX ZhoneVaIfCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the configuration table for each voice analog
interface. The entry is created when the voice analog
hardware is detected.
"
INDEX { ifIndex }
::= { zhoneVaIfCfgTable 1 }
ZhoneVaIfCfgEntry ::=
SEQUENCE {
zhoneVaIfCfgImpedance
INTEGER,
zhoneVaIfCfgReceiveTLP
INTEGER,
zhoneVaIfCfgTransmitTLP
INTEGER,
zhoneVaIfCfgTrunkConditioning
INTEGER,
zhoneVaIfCfgLineType
INTEGER,
zhoneVaIfCfgIntegratedDSP
TruthValue,
zhoneVaIfCfgLineCapabilities
BITS,
zhoneVaIfCfgMaintenanceMode
INTEGER,
zhoneVaIfCfgPCMEncoding
INTEGER,
zhoneVaIfCfgReceiveTLPNum
INTEGER,
zhoneVaIfCfgTransmitTLPNum
INTEGER,
zhoneVaIfCfgLoopCurrent
INTEGER,
zhoneVaIfCfgRingVoltage
INTEGER
}
--
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.1
zhoneVaIfCfgImpedance OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
ohms600Real(2),
ohms600Complex(3),
ohms900Complex(4),
ohmsComplex1(5),
ohmsComplex2(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the terminating impedance of voice analog
interfaces.
other - none of the following; arbitrary,
within limits, for special cases.
ohms600Real - 600 Ohms.
ohms600Complex - 600 Ohms + 2.16uF
ohms900Complex - 900 Ohms + 2.16uF.
ohmsComplex1 - Not Supported.
ohmsComplex2 - Not Supported.
Default value is ohms600Complex.
"
::= { zhoneVaIfCfgEntry 1 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.2
zhoneVaIfCfgReceiveTLP OBJECT-TYPE
SYNTAX INTEGER
{
fxsRtlpN9db(1),
fxsRtlpN8db(2),
fxsRtlpN7db(3),
fxsRtlpN6db(4),
fxsRtlpN5db(5),
fxsRtlpN4db(6),
fxsRtlpN3db(7),
fxsRtlpN2db(8),
fxsRtlpN1db(9),
fxsRtlp0db(10),
fxsRtlp1db(11),
fxsRtlp2db(12),
fxsRtlp3db(13),
rTlpNummeric(14)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Receive Transmission Level Point (RTLP) settings control the amount gain or loss added to the incoming signal after it is decoded to analog.
to increase the signal level set the RTLP setting to higher values. The default is fxsRtlpN6db. Rtlpnummeric selects entering the actual
value in zhoneVaIFCfgReceiveTLPNum."
::= { zhoneVaIfCfgEntry 2 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.3
zhoneVaIfCfgTransmitTLP OBJECT-TYPE
SYNTAX INTEGER
{
fxsTtlp9db(1),
fxsTtlp8db(2),
fxsTtlp7db(3),
fxsTtlp6db(4),
fxsTtlp5db(5),
fxsTtlp4db(6),
fxsTtlp3db(7),
fxsTtlp2db(8),
fxsTtlp1db(9),
fxsTtlp0db(10),
fxsTtlpN1db(11),
fxsTtlpN2db(12),
fxsTtlpN3db(13),
tTlpNummeric(14)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" In case of FXO, it specifies FXO attenuation and default value is 0dB(fxsTtlp0db).
In case of FXS this setting controls the amount of gain or loss added
to a voice signal from CPE before it is encoded to digital PCM.
To increase the signal level, reduce the TTLP setting to lower value.
The default is fxsTtlp0db. Ttlpnummeric selects entering the actual
value in zhoneVaIFCfgTransmitTLPNum."
::= { zhoneVaIfCfgEntry 3 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.4
zhoneVaIfCfgTrunkConditioning OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
idle(2),
busy(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The trunk conditioning setting specifies whether the FXS/FXO port should send the idle pattern to the network upon declaration of a Carrier Group Alarm(CGA) on the WAN link to which the port is assigned . In most cases leave the trunk conditioning setting at its default setting(off)."
::= { zhoneVaIfCfgEntry 4 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.5
zhoneVaIfCfgLineType OBJECT-TYPE
SYNTAX INTEGER
{
fxs(1),
fxo(2),
em(3),
ebs(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Card type FXS, FXO, EM, EBS.
Entries in the table will be created or deleted on the basis of zhoneVaIfCfgLineType
in the zhoneVaIfCfgTable and we are not using rowStatus entry for this .
The tables which are augument to the above mentioned table will be created by RP
only and they can be read or modified by user later."
DEFVAL { fxs }
::= { zhoneVaIfCfgEntry 5 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.6
zhoneVaIfCfgIntegratedDSP OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the interface has an integrated
Digital Signal processing (DSP) unit.
"
DEFVAL { false }
::= { zhoneVaIfCfgEntry 6 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.7
zhoneVaIfCfgLineCapabilities OBJECT-TYPE
SYNTAX BITS
{
fxs(0),
fxo(1),
em(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Interface types supported on this interface. This is a bit-map of possible
types. This variable can be used to determine zhoneVaIfCfgLineType."
::= { zhoneVaIfCfgEntry 7 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.8
zhoneVaIfCfgMaintenanceMode OBJECT-TYPE
SYNTAX INTEGER
{
off(1),
ifDigitalLoopback(2),
ifAnalogLoopback(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the maintenance modes of the Analog voice interface.
loopback options for Fxo and Fxs cards (Zhone specific)
-------------------------------------------------------
CODEC
T1/E1 DS0 ---------------------------
<------- <--------------- -----------------
Network PCM Bus ^ Digital ^
| to analog Converter|
| |
| |
| |
Digital loopback Analog loopback
| |
-------> -------- ->--------------------------------------------->
off(1) - the interface is not in maintenance mode.
ifDigitalLoopback(2) This mode is set by the managed system to perform the
Digital loopback test.
ifAnalogLoopback(3) This mode is set by the managed system to perform the
Analog loopback test. "
::= { zhoneVaIfCfgEntry 8 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.9
zhoneVaIfCfgPCMEncoding OBJECT-TYPE
SYNTAX INTEGER
{
alaw(1),
mulaw(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"alaw(1) :for E1
mulaw(2) : for T1 "
::= { zhoneVaIfCfgEntry 9 }
--
-- 1.3.6.1.4.1.5504.5.6.1.1.1.10
zhoneVaIfCfgReceiveTLPNum OBJECT-TYPE
SYNTAX INTEGER (-160..85)
UNITS "dB/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Receive Transmission Level Point (RTLP) settings control the amount gain or loss added to the incoming signal after it is decoded to analog.
to incrase the signal level set the RTLP setting to higher values. The default is 0 dB."
DEFVAL { '0'b }
::= { zhoneVaIfCfgEntry 10 }
-- 1.3.6.1.4.1.5504.5.6.1.1.1.11
zhoneVaIfCfgTransmitTLPNum OBJECT-TYPE
SYNTAX INTEGER (-175..70)
UNITS "dB/10"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit Transmission Level Point controls the amount of gain or loss added
to a voice signal from CPE before it is encoded to digital PCM.
To increase the signal level, reduce the TTLP setting to lower value.
The default is 0dB."
DEFVAL { 0 }
::= { zhoneVaIfCfgEntry 11 }
-- 1.3.6.1.4.1.5504.5.6.1.1.1.12
zhoneVaIfCfgLoopCurrent OBJECT-TYPE
SYNTAX INTEGER (20..44)
UNITS "mA"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To set the loop current value for a subscriber"
DEFVAL { 30 }
::= { zhoneVaIfCfgEntry 12 }
-- 1.3.6.1.4.1.5504.5.6.1.1.1.13
zhoneVaIfCfgRingVoltage OBJECT-TYPE
SYNTAX INTEGER
{
b85vrms(1),
b75vrms(2),
b92vrms(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"To set the ring voltage for a subscriber."
DEFVAL { b85vrms }
::= { zhoneVaIfCfgEntry 13 }
-- ****************************************************************************
-- The Analog Voice Interface Status Table
-- ****************************************************************************
--
-- 1.3.6.1.4.1.5504.5.6.1.2
zhoneVaIfStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Analog Voice Status Table. It contains general
information about the status of Analog Telephony interface
including the error statistics.
"
::= { zhoneVaIfGeneralObjects 2 }
-- 1.3.6.1.4.1.5504.5.6.1.2.1
zhoneVaIfStatusEntry OBJECT-TYPE
SYNTAX ZhoneVaIfStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the status table for each Analog voice interface.
"
AUGMENTS { zhoneVaIfCfgEntry }
::= { zhoneVaIfStatusTable 1 }
ZhoneVaIfStatusEntry ::=
SEQUENCE {
zhoneVaIfStatusSignalErrors
Counter32,
zhoneVaIfStatusInfoType
INTEGER
}
-- Not Supported in the current release.
-- This needs to be changed when this MIB variable is supported.
-- 1.3.6.1.4.1.5504.5.6.1.2.1.1
zhoneVaIfStatusSignalErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Accumulated number of signaling protocol errors that are
detected in the interface since system startup."
::= { zhoneVaIfStatusEntry 1 }
--
-- 1.3.6.1.4.1.5504.5.6.1.2.1.2
zhoneVaIfStatusInfoType OBJECT-TYPE
SYNTAX INTEGER
{
notype(1),
voice(2),
g3Fax(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The information transfer services for the current
call.
none - no information transfer service, this is set befgore the first call is made on the interface.
voice - analog voice.
g3Fax - Group 3 FAX.
"
::= { zhoneVaIfStatusEntry 2 }
-- 1.3.6.1.4.1.5504.5.6.2
zhoneVaIfFXSObjects OBJECT IDENTIFIER ::= { zhoneVaIfObjects 2 }
-- ****************************************************************************
-- The Foreign Exchange Station (FXS) Standard Configuration Table
-- ****************************************************************************
--
-- This table is used to configure the FXS signaling type, Ring frequency
--
-- 1.3.6.1.4.1.5504.5.6.2.1
zhoneVaIfFXSCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfFXSCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FXS standard configuration table. It contains
FXS configuration parameters, one entry per FXS interface.
The configuration information of this table is set by
hardware with its default setting or CLI during the hardware
installation time.
"
::= { zhoneVaIfFXSObjects 1 }
-- 1.3.6.1.4.1.5504.5.6.2.1.1
zhoneVaIfFXSCfgEntry OBJECT-TYPE
SYNTAX ZhoneVaIfFXSCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the standard configuration table for
each FXS interface."
INDEX { ifIndex }
::= { zhoneVaIfFXSCfgTable 1 }
ZhoneVaIfFXSCfgEntry ::=
SEQUENCE {
zhoneVaIfFXSCfgSignalType
INTEGER,
zhoneVaIfFXSRingFrequency
INTEGER,
zhoneVaIfFXSRingBack
INTEGER
}
--
--
-- 1.3.6.1.4.1.5504.5.6.2.1.1.1
zhoneVaIfFXSCfgSignalType OBJECT-TYPE
SYNTAX INTEGER
{
fxsLoopStart(1),
fxsGroundStart(2),
fxsLoopStartFd(3),
fxsGroundStartAutomatic(4),
fxsGroundStartImmediate(5),
fxsdnLoopStart(6),
fxsdnLoopStartFd(7),
fxsdnGroundStart(8),
fxsdnGroundStartImmediate(9),
fxsdnwinkLoopStart(10),
fxsdnwinkLoopStartFd(11),
fxsdnwinkGroundStart(12),
fxsdnwinkGroundStartImmediate(13),
fxstr08SingleParty(14),
fxstr08UniversalVoiceGrade(15),
fxstr08UniversalVoiceGradeAutomatic(16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the signaling type of FXS interface.
fxsLoopStart - loop start.
fxsGroundStart - ground start.
fxsLoopStartFd
fxsGroundStartAutomatic - Used with equipment requiring fast response time to the Central Office.
fxsGroundStartImmediate - Used with equipment requiring fast response time to the station or PBX.
fxsdnLoopStart- loop start in fxsdn mode
fxsdnLoopStartFd
fxsdnGroundStart- Ground start in fxsdn mode
fxsdnGroundStartImmediate - Ground start immediate in fxsdn mode
fxsdnwinkLoopStart - loop start in fxsdnwink (foreign exchange
subscriber - defined wink start operation) this
option proved the same type of signalling as
FXSDN and provides 150 millisecond delay then
200 ms wink ack to the central office when fxs port sees an off hook condition from central office .
The system requires a ringing generator for this option.
fxsdnwinkLoopStartFd
fxsdnwinkGroundStart- Ground start in FXSDNWINK mode
fxsdnwinkGroundStartImmediate - Ground start immediate in FXSDNWINK mode.
fxstr08SingleParty - TR08 is Frame format signalling and data link as defined in TR-TSY-00008 Mode 1
for circuits using AT & T SLC-96 facilities.
this option is for single party service ,
this option connects the port to one way out going trunks from a PBX , CENTEREX, key system , ot telephone set to an SLC channel.
The SLC96 mode also must be active on the associated WAN interface.
fxstr08UniversalVoiceGrade - Toll quality voice for SLC-96
fxstr08UniversalVoiceGradeAutomatic- Used with some non - Bell switches for SLC-96
The default value of this object is fxsLoopStart(1).
"
::= { zhoneVaIfFXSCfgEntry 1 }
-- --
--
-- 1.3.6.1.4.1.5504.5.6.2.1.1.2
zhoneVaIfFXSRingFrequency OBJECT-TYPE
SYNTAX INTEGER
{
ringFrequency25(1),
ringFrequency50(2),
ringFrequency20(3),
ringFrequency30(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the ring frequency to be used in the FXS interface.
ringFrequency25 - ring frequency 25 Hertz.
ringFrequency50 - ring frequency 50 Hertz.
ringFrequency20 - ring frequency 20 Hertz.(Default)
ringFrequency30 - ring frequency 30 Hertz.
"
::= { zhoneVaIfFXSCfgEntry 2 }
-- --
-- 1.3.6.1.4.1.5504.5.6.2.1.1.3
zhoneVaIfFXSRingBack OBJECT-TYPE
SYNTAX INTEGER
{
on(1),
off(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the ring back is requested if this variable is set to on."
::= { zhoneVaIfFXSCfgEntry 3 }
-- ****************************************************************************
-- The Foreign Exchange Station (FXS) interface Status Table
-- ****************************************************************************
--
-- 1.3.6.1.4.1.5504.5.6.2.2
zhoneVaIfFXSStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfFXSStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Foreign Exchange Station (FXS) interface Status Table.
It contains hook status, ring active and other states of
the interface.
"
::= { zhoneVaIfFXSObjects 2 }
-- 1.3.6.1.4.1.5504.5.6.2.2.1
zhoneVaIfFXSStatusEntry OBJECT-TYPE
SYNTAX ZhoneVaIfFXSStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the status table for each FXS interface.
"
AUGMENTS { zhoneVaIfFXSCfgEntry }
::= { zhoneVaIfFXSStatusTable 1 }
ZhoneVaIfFXSStatusEntry ::=
SEQUENCE {
zhoneVaIfFXSHookStatus
INTEGER,
zhoneVaIfFXSRingActive
TruthValue,
zhoneVaIfFXSRingGround
TruthValue,
zhoneVaIfFXSTipGround
TruthValue
}
--
-- 1.3.6.1.4.1.5504.5.6.2.2.1.1
zhoneVaIfFXSHookStatus OBJECT-TYPE
SYNTAX INTEGER
{
onHook(1),
offHook(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the hook status of FXS interface.
onHook - the connected equipment(e.g., phone) is onHook.
offHook - the connected equipment is offHook.
"
::= { zhoneVaIfFXSStatusEntry 1 }
--
-- 1.3.6.1.4.1.5504.5.6.2.2.1.2
zhoneVaIfFXSRingActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the outgoing ring active indication. If
the object value is true, then the interface is currently
generating ring out to the Key Telephone System (KTS) or
Plain Old Telephone (POT); otherwise, it doesn't.
"
DEFVAL { false }
::= { zhoneVaIfFXSStatusEntry 2 }
--
-- 1.3.6.1.4.1.5504.5.6.2.2.1.3
zhoneVaIfFXSRingGround OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming ring ground indication.
It is only valid when the zvaIfFXSCfgSignalType is
fxsGroundStart. If the object is true, then the interface
is presenting a ring ground to the connected equipment;
otherwise, it doesn't.
"
DEFVAL { false }
::= { zhoneVaIfFXSStatusEntry 3 }
-- --
--
-- 1.3.6.1.4.1.5504.5.6.2.2.1.4
zhoneVaIfFXSTipGround OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming tip ground indication.
It is only valid when the zvaIfFXSCfgSignalType is
fxsGroundStart. If the object is true, then the interface
is detecting a tip ground at the interface; otherwise,
it doesn't.
"
DEFVAL { false }
::= { zhoneVaIfFXSStatusEntry 4 }
-- ****************************************************************************
-- The FXS Timing Parameters Table
-- ****************************************************************************
-- This table contains the FXS interface timing parameters information.
--
-- 1.3.6.1.4.1.5504.5.6.2.3
zhoneVaIfFXSTimingTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfFXSTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FXS interface Timing Parameters table. It
contains the configuration of the various FXS signaling
protocol timing parameters.
"
::= { zhoneVaIfFXSObjects 3 }
-- 1.3.6.1.4.1.5504.5.6.2.3.1
zhoneVaIfFXSTimingEntry OBJECT-TYPE
SYNTAX ZhoneVaIfFXSTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the FXS Timing Parameters Table for
each FXS interface."
AUGMENTS { zhoneVaIfFXSCfgEntry }
::= { zhoneVaIfFXSTimingTable 1 }
ZhoneVaIfFXSTimingEntry ::=
SEQUENCE {
zhoneVaIfFXSTimingDigitDuration
Integer32,
zhoneVaIfFXSTimingInterDigitDuration
Integer32
}
-- 1.3.6.1.4.1.5504.5.6.2.3.1.1
zhoneVaIfFXSTimingDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF digit duration in milliseconds.
The default value of this object is 100 milliseconds.
This field is not supported.
"
::= { zhoneVaIfFXSTimingEntry 1 }
--
--
-- 1.3.6.1.4.1.5504.5.6.2.3.1.2
zhoneVaIfFXSTimingInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF inter-digit duration in milliseconds.
The default value of this object is 100 milliseconds.
This field is not supported.
"
::= { zhoneVaIfFXSTimingEntry 2 }
-- 1.3.6.1.4.1.5504.5.6.2.4
zhonePotsRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhonePotsRingEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Table to execute diagnostic potsring command.
Row in table with non-zero timer will ring pots port.
Currently, maximum of 4 rows at a time are supported."
::= { zhoneVaIfFXSObjects 4 }
-- 1.3.6.1.4.1.5504.5.6.2.4.1
zhonePotsRingEntry OBJECT-TYPE
SYNTAX ZhonePotsRingEntry
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"potsring table entry"
INDEX { zhonePotsRingIfIndex }
::= { zhonePotsRingTable 1 }
ZhonePotsRingEntry ::=
SEQUENCE {
zhonePotsRingIfIndex
InterfaceIndex,
zhonePotsRingRingingCadence
INTEGER,
zhonePotsRingTimer
Integer32,
zhonePotsRingRowStatus
ZhoneRowStatus
}
-- 1.3.6.1.4.1.5504.5.6.2.4.1.1
zhonePotsRingIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"Physical pots interface."
::= { zhonePotsRingEntry 1 }
-- 1.3.6.1.4.1.5504.5.6.2.4.1.2
zhonePotsRingRingingCadence OBJECT-TYPE
SYNTAX INTEGER
{
ring-cadence-r0(1),
ring-cadence-r1(2),
ring-cadence-r2(3),
ring-cadence-r3(4),
ring-cadence-r4(5),
ring-cadence-r5(6),
ring-cadence-r6(7),
ring-cadence-r7(8),
ring-cadence-common(9),
ring-cadence-splash(10)
}
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Ring cadence to use in test."
DEFVAL { 9 }
::= { zhonePotsRingEntry 2 }
-- 1.3.6.1.4.1.5504.5.6.2.4.1.3
zhonePotsRingTimer OBJECT-TYPE
SYNTAX Integer32 (1..9999)
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Time in seconds to continue ringing."
DEFVAL { 15 }
::= { zhonePotsRingEntry 3 }
-- 1.3.6.1.4.1.5504.5.6.2.4.1.4
zhonePotsRingRowStatus OBJECT-TYPE
SYNTAX ZhoneRowStatus
MAX-ACCESS read-create
STATUS deprecated
DESCRIPTION
"Row status"
::= { zhonePotsRingEntry 4 }
-- 1.3.6.1.4.1.5504.5.6.3
zhoneVaIfFXOObjects OBJECT IDENTIFIER ::= { zhoneVaIfObjects 3 }
-- ****************************************************************************
-- The Foreign Exchange Office (FXO) Standard Configuration Table
-- ****************************************************************************
--
-- This table is used to configure the FXO signaling and number of rings
-- for the FXO interface.
--
-- 1.3.6.1.4.1.5504.5.6.3.1
zhoneVaIfFXOCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfFXOCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FXO standard configuration table. It contains
FXO configuration parameters, one entry per FXO interface.
The configuration information of this table is set by
hardware with its default setting or CLI during the hardware
installation time.
"
::= { zhoneVaIfFXOObjects 1 }
-- 1.3.6.1.4.1.5504.5.6.3.1.1
zhoneVaIfFXOCfgEntry OBJECT-TYPE
SYNTAX ZhoneVaIfFXOCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the standard configuration table for
each FXO interface."
INDEX { ifIndex }
::= { zhoneVaIfFXOCfgTable 1 }
ZhoneVaIfFXOCfgEntry ::=
SEQUENCE {
zhoneVaIfFXOCfgSignalType
INTEGER,
zhoneVaIfFXOCfgNumberRings
Integer32,
zhoneVaIfFXOCfgSupDisconnect
TruthValue,
zhoneVaIfFXOCfgDialType
INTEGER
}
--
-- 1.3.6.1.4.1.5504.5.6.3.1.1.1
zhoneVaIfFXOCfgSignalType OBJECT-TYPE
SYNTAX INTEGER
{
fxoLoopStart(1),
fxoGroundStart(2),
fxodpt(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the signaling type of FXO interface.
fxoLoopStart - loop start.
fxoGroundStart - ground start.
fxodpt- Dial Pulse Terminating , this option allows the unit to attach to incoming one way trunks from a PBX , key system or a telephone set..
The default value of this object is fxoLoopStart(1).
"
::= { zhoneVaIfFXOCfgEntry 1 }
-- 1.3.6.1.4.1.5504.5.6.3.1.1.2
zhoneVaIfFXOCfgNumberRings OBJECT-TYPE
SYNTAX Integer32 (1..10)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of rings detected before closing loop.
The default value of this object is 1 ring."
::= { zhoneVaIfFXOCfgEntry 2 }
-- 1.3.6.1.4.1.5504.5.6.3.1.1.3
zhoneVaIfFXOCfgSupDisconnect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Specifies whether a supervisory disconnect signal (CPC) will
be presented to the interface when the connected party at
the interface hangs up.
The default value of this object is 'true'.
"
DEFVAL { false }
::= { zhoneVaIfFXOCfgEntry 3 }
-- 1.3.6.1.4.1.5504.5.6.3.1.1.4
zhoneVaIfFXOCfgDialType OBJECT-TYPE
SYNTAX INTEGER
{
dtmf(1),
pulse(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the out dialing type of FXO interface.
dtmf - DTMF digit.
pulse - pulse.
The default value of this object is dtmf(1).
"
::= { zhoneVaIfFXOCfgEntry 4 }
-- ****************************************************************************
-- The Foreign Exchange Office (FXO) interface Status Table
-- ****************************************************************************
--
-- 1.3.6.1.4.1.5504.5.6.3.2
zhoneVaIfFXOStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfFXOStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Foreign Exchange Office (FXO) interface Status Table.
It contains hook status, ring detection and other states of
the interface.
"
::= { zhoneVaIfFXOObjects 2 }
-- 1.3.6.1.4.1.5504.5.6.3.2.1
zhoneVaIfFXOStatusEntry OBJECT-TYPE
SYNTAX ZhoneVaIfFXOStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the status table for each FXO interface.
"
AUGMENTS { zhoneVaIfFXOCfgEntry }
::= { zhoneVaIfFXOStatusTable 1 }
ZhoneVaIfFXOStatusEntry ::=
SEQUENCE {
zhoneVaIfFXOHookStatus
INTEGER,
zhoneVaIfFXORingDetect
TruthValue,
zhoneVaIfFXORingGround
TruthValue,
zhoneVaIfFXOTipGround
TruthValue
}
--
-- 1.3.6.1.4.1.5504.5.6.3.2.1.1
zhoneVaIfFXOHookStatus OBJECT-TYPE
SYNTAX INTEGER
{
onHook(1),
offHook(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the hook status of FXO interface.
onHook - Present the onHook to the connected equipment.
offHook - Present the offHook to the connected equipment.
"
::= { zhoneVaIfFXOStatusEntry 1 }
--
-- 1.3.6.1.4.1.5504.5.6.3.2.1.2
zhoneVaIfFXORingDetect OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the ring detect indication. If the
value is true, then the interface detects ring from PBX or
CO; otherwise, it doesn't."
DEFVAL { false }
::= { zhoneVaIfFXOStatusEntry 2 }
--
-- 1.3.6.1.4.1.5504.5.6.3.2.1.3
zhoneVaIfFXORingGround OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming ring ground indication.
It is only valid when the zvaIfFXOCfgSignalType is
fxoGroundStart. If the object is true, then the interface
is presenting a ring ground to the connected equipment;
otherwise, it doesn't.
"
DEFVAL { false }
::= { zhoneVaIfFXOStatusEntry 3 }
--
-- 1.3.6.1.4.1.5504.5.6.3.2.1.4
zhoneVaIfFXOTipGround OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming tip ground indication.
It is only valid when the zvaIfFXOCfgSignalType is
fxoGroundStart. If the object is true, then the interface
is detecting a tip ground at the interface; otherwise,
it doesn't.
"
DEFVAL { false }
::= { zhoneVaIfFXOStatusEntry 4 }
-- ****************************************************************************
-- The FXO Timing Parameters Table
-- ****************************************************************************
-- This table contains the FXO interface timing parameters information.
--
-- 1.3.6.1.4.1.5504.5.6.3.3
zhoneVaIfFXOTimingTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfFXOTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The FXO interface Timing Parameters table. It
contains the configuration of the various FXO signaling
protocol timing parameters.
"
::= { zhoneVaIfFXOObjects 3 }
-- 1.3.6.1.4.1.5504.5.6.3.3.1
zhoneVaIfFXOTimingEntry OBJECT-TYPE
SYNTAX ZhoneVaIfFXOTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the FXO Timing Parameters Table for
each FXO interface."
AUGMENTS { zhoneVaIfFXOCfgEntry }
::= { zhoneVaIfFXOTimingTable 1 }
ZhoneVaIfFXOTimingEntry ::=
SEQUENCE {
zhoneVaIfFXOTimingDigitDuration
Integer32,
zhoneVaIfFXOTimingInterDigitDuration
Integer32,
zhoneVaIfFXOTimingPulseRate
Integer32,
zhoneVaIfFXOTimingPulseInterDigitDuration
Integer32
}
-- 1.3.6.1.4.1.5504.5.6.3.3.1.1
zhoneVaIfFXOTimingDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF digit duration in milliseconds.
The default value of this object is 100 msec.
"
::= { zhoneVaIfFXOTimingEntry 1 }
-- 1.3.6.1.4.1.5504.5.6.3.3.1.2
zhoneVaIfFXOTimingInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF inter-digit duration in milliseconds.
The default value of this object is 100 msec.
"
::= { zhoneVaIfFXOTimingEntry 2 }
-- 1.3.6.1.4.1.5504.5.6.3.3.1.3
zhoneVaIfFXOTimingPulseRate OBJECT-TYPE
SYNTAX Integer32 (10..20)
UNITS "pps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing pulse dialing rate in pulses per second (pps).
The default value of this object is 10 pps.
"
::= { zhoneVaIfFXOTimingEntry 3 }
-- 1.3.6.1.4.1.5504.5.6.3.3.1.4
zhoneVaIfFXOTimingPulseInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (100..1000)
UNITS "pps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing pulse dialing inter-digit timing in milliseconds.
The default value of this object is 500 milliseconds.
"
::= { zhoneVaIfFXOTimingEntry 4 }
-- 1.3.6.1.4.1.5504.5.6.4
zhoneVaIfEMObjects OBJECT IDENTIFIER ::= { zhoneVaIfObjects 4 }
--
-- ****************************************************************************
-- The E&M Standard Configuration Table
-- ****************************************************************************
--
-- This table is used to configure the E&M type, signaling, operation,
-- dial type for the E&M interface.
--
-- 1.3.6.1.4.1.5504.5.6.4.1
zhoneVaIfEMCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfEMCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The E&M standard configuration table. It contains
the current setting of E&M configurable parameters.
"
::= { zhoneVaIfEMObjects 1 }
-- 1.3.6.1.4.1.5504.5.6.4.1.1
zhoneVaIfEMCfgEntry OBJECT-TYPE
SYNTAX ZhoneVaIfEMCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the standard configuration table for
each E&M tie trunk interface."
INDEX { ifIndex }
::= { zhoneVaIfEMCfgTable 1 }
ZhoneVaIfEMCfgEntry ::=
SEQUENCE {
zhoneVaIfEMCfgSignalType
INTEGER,
zhoneVaIfEMCfgOperation
INTEGER,
zhoneVaIfEMCfgType
INTEGER,
zhoneVaIfEMCfgDialType
INTEGER
}
-- 1.3.6.1.4.1.5504.5.6.4.1.1.1
zhoneVaIfEMCfgSignalType OBJECT-TYPE
SYNTAX INTEGER
{
winkStart(1),
immediateDial(2),
delayDial(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The signaling type of E&M tie trunk interface.
winkStart - the calling side seizes the line by going
off-hook on its E lead but waits for a short
off-hook 'wink' indication on its M lead from
the called side before sending address
information as DTMF digits.
immediateDial - the calling side seizes the line by going
off-hook on its E lead and sends sends address
information as DTMF digits.
delayDial - the calling side seizes the line by going
off-hook on its E lead. After a timing interval,
the calling side looks at the supervision
from the called side. If the supervision is
on-hook, the calling side starts sending
information as DTMF digits; otherwise, the calling
side waits until the called side goes
on-hook and then starts sending address
information.
The default value of this object is winkStart(1).
"
REFERENCE
"EIA/TIA-464B: Sections 4.1.3.4.1 Signaling Protocols.
"
::= { zhoneVaIfEMCfgEntry 1 }
-- 1.3.6.1.4.1.5504.5.6.4.1.1.2
zhoneVaIfEMCfgOperation OBJECT-TYPE
SYNTAX INTEGER
{
twoWires(1),
fourWires(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specify the operation of the E&M signal.
twoWires - 2-wire operation.
fourWires - 4-wire operation.
The default value of this object is twoWires(1).
"
::= { zhoneVaIfEMCfgEntry 2 }
-- 1.3.6.1.4.1.5504.5.6.4.1.1.3
zhoneVaIfEMCfgType OBJECT-TYPE
SYNTAX INTEGER
{
typeI(1),
typeII(2),
typeIII(3),
typeIV(4),
typeV(5),
typeIIE(6),
typeIIM(7),
typeTO(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the E&M Lead Signaling type.
LEGEND: V = -48V
/\/\/ = detector/resister
X = normally open relay contact
+ = normally closed relay contact
G = ground
SB = Signal Battery
SG = Signal Ground
typeI -
Leads: E (output, relay to ground)
M (input, referenced to ground)
The tie line equipment (switch/router/etc) generates the
E-signal to the PBX type grounding the E-lead.
The tie line equipment detects the M-signal by detecting
current flow to ground. A common ground must exist
between the line equipment and the PBX.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----G
|
M: V----X-----|---/\/\/--G
typeII -
Leads: E (output, relay to SG)
M (input, referenced to ground)
SB (feed for M, connected to -48V)
SG (return for E, galvanically isolated from ground)
This interface requires no common ground between the
equipment, thus avoiding ground loop noise problems.
E-signal is generated toward the PBX by connecting it
to SG. M-signal is indicated by the PBX connecting
it to SB. While this interface does NOT require a
common ground, it does have the tendency to inject
noise into the audio paths since it is asymmetrical
with respect to current flow between devices.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----
| |
SG: G----------|----------
|
M: ----X-----|---/\/\/--G
| |
SB: ----------|----------V
typeIII -
Leads: E (output, relay to ground)
M (input, referenced to ground)
SB (connected to -48V)
SG (connected to ground)
This interface operates similar to type I with respect
to the E-signal. The M-signal, however, is indicated by
the PBX connecting it to SB on assertion, and alternately
connecting it to SG during inactivity. Unfortunately, a
common ground must be shared between the equipment.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----G
|
SG: ----------|----------G
+ |
M: ----------|---/\/\/--G
X |
SB: ----------|----------V
typeIV -
Leads: E (output, relay to SG)
M (input, referenced to -48V)
SB (feed for M, connected to ground)
SG (return for E, galvanically isolated from ground)
This interface is fully symmetrical; it does not require
a common ground, does not inject noise into audio paths,
and can be connected back to back by swapping E/SG for
M/SB. E-signal is indicated to the PBX by connecting it
to SG. M-signal is provided by the PBX connecting it to
SB.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----
| |
SG: G----------|----------
|
M: ----------|---/\/\/--V
X |
SB: ----------|----------G
typeV -
Leads: E (output, relay to ground)
M (input, referenced to -48V)
Type V line equipment indicates E-signal to the PBX by
grounding the E-lead. The PBX indicates M-signal by
grounding the M-lead. This interface does require a
common ground, but does allow back to back connections
by swapping E for M. This interface is quasi-symmetric
in that while the line is up, current flow is more or
less equal between the PBX and line equipment. But noise
injection is still a problem.
PBX | TIE LINE
|
E: V--/\/\/---|-----X----G
|
M: G-----X----|---/\/\/--V
|
The default value of this object is typeI(1).
"
REFERENCE
"EIA/TIA-464B: Sections 4.2.3 E&M Lead Signaling.
"
::= { zhoneVaIfEMCfgEntry 3 }
-- 1.3.6.1.4.1.5504.5.6.4.1.1.4
zhoneVaIfEMCfgDialType OBJECT-TYPE
SYNTAX INTEGER
{
dtmf(1),
pulse(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the out dialing type of E&M interface.
dtmf - DTMF digit.
pulse - pulse.
The default value of this object is dtmf(1).
"
::= { zhoneVaIfEMCfgEntry 4 }
-- ****************************************************************************
-- The E&M interface Status Table
-- ****************************************************************************
--
-- 1.3.6.1.4.1.5504.5.6.4.2
zhoneVaIfEMStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfEMStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The E&M interface Table. The table contains
the status of the E&M tie trunk interface.
"
::= { zhoneVaIfEMObjects 2 }
-- 1.3.6.1.4.1.5504.5.6.4.2.1
zhoneVaIfEMStatusEntry OBJECT-TYPE
SYNTAX ZhoneVaIfEMStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the status table for each E&M interface.
"
AUGMENTS { zhoneVaIfEMCfgEntry }
::= { zhoneVaIfEMStatusTable 1 }
ZhoneVaIfEMStatusEntry ::=
SEQUENCE {
zhoneVaIfEMInSeizureActive
TruthValue,
zhoneVaIfEMOutSeizureActive
TruthValue
}
-- 1.3.6.1.4.1.5504.5.6.4.2.1.1
zhoneVaIfEMInSeizureActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the incoming seizure state of the E&M
interface. If the value is true, then the interface has an
incoming trunk seizure active; otherwise, it doesn't.
"
DEFVAL { false }
::= { zhoneVaIfEMStatusEntry 1 }
-- 1.3.6.1.4.1.5504.5.6.4.2.1.2
zhoneVaIfEMOutSeizureActive OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains the outgoing seizure state of the E&M
interface. If the value is true, then the interface has an
outgoing trunk seizure active; otherwise, it doesn't.
"
DEFVAL { false }
::= { zhoneVaIfEMStatusEntry 2 }
-- ****************************************************************************
-- The E&M Timing Parameters Table
-- ****************************************************************************
--
-- This table contains the E&M interface timing parameters information.
--
-- 1.3.6.1.4.1.5504.5.6.4.3
zhoneVaIfEMTimingTable OBJECT-TYPE
SYNTAX SEQUENCE OF ZhoneVaIfEMTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The E&M tie trunk Timing Parameters table. It
contains the configuration of the various E&M signaling
protocol timing parameters.
"
::= { zhoneVaIfEMObjects 3 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1
zhoneVaIfEMTimingEntry OBJECT-TYPE
SYNTAX ZhoneVaIfEMTimingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the E&M Timing Parameters Table for
each E&M interface."
AUGMENTS { zhoneVaIfEMCfgEntry }
::= { zhoneVaIfEMTimingTable 1 }
ZhoneVaIfEMTimingEntry ::=
SEQUENCE {
zhoneVaIfEMTimingDigitDuration
Integer32,
zhoneVaIfEMTimingInterDigitDuration
Integer32,
zhoneVaIfEMTimingPulseRate
Integer32,
zhoneVaIfEMTimingPulseInterDigitDuration
Integer32,
zhoneVaIfEMTimingClearWaitDuration
Integer32,
zhoneVaIfEMTimingMaxWinkWaitDuration
Integer32,
zhoneVaIfEMTimingMaxWinkDuration
Integer32,
zhoneVaIfEMTimingDelayStart
Integer32,
zhoneVaIfEMTimingMaxDelayDuration
Integer32,
zhoneVaIfEMTimingMinDelayPulseWidth
Integer32
}
-- 1.3.6.1.4.1.5504.5.6.4.3.1.1
zhoneVaIfEMTimingDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF digit duration in milliseconds.
The default value of this object is 100 milliseconds.
"
::= { zhoneVaIfEMTimingEntry 1 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.2
zhoneVaIfEMTimingInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (50..500)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing DTMF inter-digit duration in milliseconds.
The default value of this object is 100 milliseconds.
"
::= { zhoneVaIfEMTimingEntry 2 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.3
zhoneVaIfEMTimingPulseRate OBJECT-TYPE
SYNTAX Integer32 (10..20)
UNITS "pps"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing pulse dialing rate in pulses per second (pps).
The default value of this object is 10 pps.
"
::= { zhoneVaIfEMTimingEntry 3 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.4
zhoneVaIfEMTimingPulseInterDigitDuration OBJECT-TYPE
SYNTAX Integer32 (100..1000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Outgoing Pulse dialing inter-digit timing in milliseconds.
The default value of this object is 500 milliseconds.
"
::= { zhoneVaIfEMTimingEntry 4 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.5
zhoneVaIfEMTimingClearWaitDuration OBJECT-TYPE
SYNTAX Integer32 (200..2000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time of Inactive seizure signal to declare call cleared.
The default value of this object is 400 milliseconds."
::= { zhoneVaIfEMTimingEntry 5 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.6
zhoneVaIfEMTimingMaxWinkWaitDuration OBJECT-TYPE
SYNTAX Integer32 (100..5000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum time to wait from the outgoing seizure of the line
to the time of sending out a wink-pulse.
The default value of this object is 200 milliseconds."
::= { zhoneVaIfEMTimingEntry 6 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.7
zhoneVaIfEMTimingMaxWinkDuration OBJECT-TYPE
SYNTAX Integer32 (100..3000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum outgoing wink duration (between the wink-pulse leading
edge and trailing edge) for wink start signaling.
The default value of this object is 200 milliseconds."
::= { zhoneVaIfEMTimingEntry 7 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.8
zhoneVaIfEMTimingDelayStart OBJECT-TYPE
SYNTAX Integer32 (20..2000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum time to wait from outgoing seizure to
out-dialing digits for delay start signaling.
The default value of this object is 300 milliseconds.
"
::= { zhoneVaIfEMTimingEntry 8 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.9
zhoneVaIfEMTimingMaxDelayDuration OBJECT-TYPE
SYNTAX Integer32 (100..5000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Maximum time to wait from outgoing seizure to
out-dialing digits. If the far end does not allow to
send digits after the duration specified in the object,
a reorder tone will be sent to the calling party.
The default value of this object is 2000 milliseconds."
::= { zhoneVaIfEMTimingEntry 9 }
-- 1.3.6.1.4.1.5504.5.6.4.3.1.10
zhoneVaIfEMTimingMinDelayPulseWidth OBJECT-TYPE
SYNTAX Integer32 (0 | 140..5000)
UNITS "milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Minimum delay-dial pulse duration for incoming call.
If the value of this object is 0, then no delay-dial
is sent to the far end for the incoming call.
The default value of this object is 140 milliseconds."
::= { zhoneVaIfEMTimingEntry 10 }
END
--