-- genLineRedundancy.mib
-- MIB generated by MG-SOFT Visual MIB Builder Version 2.0 Build 187
-- Monday, November 06, 2000 at 19:07:09
--
-- The ZHONE-RedundantLine-MIB defines a set of
-- variables to manage line interfaces under the
-- Zhone Technologies management system. Lines are
-- described by line profiles, and lines related to
-- one another through a line-sparing redundancy
-- are grouped into a lineGroup.
ZHONE-GEN-LINE-REDUNDANCY DEFINITIONS ::= BEGIN
IMPORTS
ifIndex, InterfaceIndex
FROM IF-MIB
Integer32, OBJECT-TYPE, MODULE-IDENTITY
FROM SNMPv2-SMI
TEXTUAL-CONVENTION
FROM SNMPv2-TC
zhoneInterfaceGroup, zhoneModules
FROM Zhone
ZhoneAdminString, ZhoneShelfValue, ZhoneSlotValue, ZhoneRowStatus
FROM Zhone-TC;
-- This header defines the structures generated by the MIB
-- variables declared in this module.
--
-- The line redundancy groups are described by the Line_Group record
-- which is defined in the file lineGroup.h. and lineGroup.c.
-- The record is called "line-group" in the CLI.
-- Each record is locatd uneder the "interface/groups" branch of the
-- CLI profile tree, and is stored by groupId.
--
--
--
-- The line profiles are described by the Line_Profile record
-- which is defined in the file lineProf.h and lineProf.c.
-- The record is called "line-profile" in the CLI.
-- Each record is located under the "interface/profiles" branch of the
-- CLI profile tree, and is stored by profileId.
--
--
--
--
-- I propose we use ZHONE_INFRA for generic pieces which
-- must always be there.
zhoneRedundantLine MODULE-IDENTITY
LAST-UPDATED "200011031722Z"
ORGANIZATION
"Zhone Technologies"
CONTACT-INFO
" Postal:
Zhone Technologies, Inc.
@ Zhone Way
7001 Oakport Street
Oakland, CA 94621
USA
Toll-Free: +1 877-ZHONE20 (+1 877-946-6320)
Tel: +1-510-777-7000
Fax: +1-510-777-7001
E-mail: support@zhone.com"
DESCRIPTION
"The Zhone Interface Group MIB defines variables for
managing related groups of interfaces and allows
pairs of lines to be grouped for redundancy.
Note that the channelized entities (i.e. DS1 channels
on a DS3 line) will not be included in this table."
REVISION "200009121801Z"
DESCRIPTION
"V01.00.00 - Initial Release"
REVISION "200010251646Z"
DESCRIPTION
"V01.00.01 - re-generated"
REVISION "200011031943Z"
DESCRIPTION
"Added IfIndex type identifier
in Zhone Keyword markup for Line Profile
index value"
REVISION "200011061853Z"
DESCRIPTION
"V01.00.04 - Fix OID numbering"
::= { zhoneModules 9 }
--
-- Textual conventions
--
InterfaceIndexOrZero ::= TEXTUAL-CONVENTION
DISPLAY-HINT
"d"
STATUS current
DESCRIPTION
"This textual convention is an extension of the
InterfaceIndex convention. The latter defines a
greater than zero value used to identify an interface
or interface sub-layer in the managed system. This
extension permits the additional value of zero. the
value zero is object-specific and must therefore be
defined as part of the description of any object which
uses this syntax. Examples of the usage of zero might
include situations where interface was unknown, or
when none or all interfaces need to be referenced."
SYNTAX Integer32 (0..2147483647)
--
-- Node definitions
--
nextLineGroupId OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The next available line group id which can be used
by the manager when creating a line group. A 'get'
to this field, causes the number to be returned
and the value to be incremented for the next
requester.
The range for nextLineGroupId is 0..2147483647
where the value 0 indicates that no unassigned
entries are available."
::= { zhoneInterfaceGroup 1 }
lineProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF LineProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table which contains Zhone-specific
descriptions of each physical line. There is one
entry for each physical line in the system and
it's primary use is for a user to specify redundant
lines in the system.
An entry is automatically created by the associated
driver whenever a new card is inserted in the
system (specifically when an ifindex value is
allocated for this port).
Statistics, admin state, and operational state
can be obtained by the matching ifEntry.
This line is part of a redundancy group if the
lgRedundancyGroupId is non-zero. This value is a
cross-reference to the maching line redundancy group
table and must be created by the user.
In order for a line/ifEntry to be admin'd active,
this line MUST be part of a line redundancy group
(even if no redundancy is being configured)."
::= { zhoneInterfaceGroup 2 }
-- The entry describes a line profile, which are all of
-- the settable parameters associated with every line.
-- The name is an arbitrary label assigned by the user.
-- The physical address is the shelf/slot/port/subPort
-- at which the line is attached. The RGName identifies
-- the line group which this line belongs to, and is set
-- to an empty string if there is no redundant line,
-- such as with an ethernet interface. The port type
-- identifies the physica media attached to the line,
-- and the ifIndex is the SNMP index used to locate the
-- ifTable entry for this line, which provides for
-- control and monitoring.
lineProfileEntry OBJECT-TYPE
SYNTAX LineProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entry describing a single physical line in the
line profile table."
INDEX { ifIndex }
::= { lineProfileTable 1 }
LineProfileEntry ::=
SEQUENCE {
lpDescription
ZhoneAdminString,
lpPhysicalShelf
ZhoneShelfValue,
lpPhysicalSlot
ZhoneSlotValue,
lpPhysicalPort
Integer32,
lpPhysicalSubPort
Integer32,
lpRedundancyGroupId
Integer32
}
--
--
lpDescription OBJECT-TYPE
SYNTAX ZhoneAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A descriptive name the user can enter. It is not used
by the operating software and more than likely the
user only should modify the description in the
ifTable.
"
::= { lineProfileEntry 1 }
lpPhysicalShelf OBJECT-TYPE
SYNTAX ZhoneShelfValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical address or number of the shelf where
desired line is located. A Zhone system is limited
to a maximum of 255 shelves. The first shelf in a
system is shelf 1."
::= { lineProfileEntry 2 }
lpPhysicalSlot OBJECT-TYPE
SYNTAX ZhoneSlotValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical slot number on which the the card
containing the port for the line profile is located.
Zhone shelves are currently limited to a maximum of
17 slots numbered 1-17."
::= { lineProfileEntry 3 }
lpPhysicalPort OBJECT-TYPE
SYNTAX Integer32 (1..262143)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number defines the physical port number on
the selected shel/slot for the line profile. Port
numbering begins with 1 and are numbered sequentially.
The valid range of port numbers is 1..262143.
lpPhysicalPort 0 is invalid."
::= { lineProfileEntry 4 }
lpPhysicalSubPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lpPhysicalSubPort is used to identify multiple
logical ports on a physical port that require their
own line profiles.
Value of 0 indicates there is no lpPhysicalsubPort"
::= { lineProfileEntry 5 }
lpRedundancyGroupId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The matching id of the line redundancy group (lgId)
of which this line is a part. This field must be
set, even if the line is not a redundant pair but is
being utilized in the system. The user may have
lines configured but not part of a redundancy group
which just means this line is in the process of being
configured.
When the line profile is initially created, it
is NOT part of a line redundancy group (value =0)."
::= { lineProfileEntry 6 }
lineGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF LineGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The lineGroupTable contains descriptions of the
redundancy relationship between lines. Each of the
two lines are given a weight between 1 and 10 which
is used to determine their role.
Each line is referenced by an ID (ifIndex) used to
access the ifEntry and lineProfile tables. The use of
Primary/Secondary naming convention is arbitrary and
specifying either does not guarantee any particular
line having additional priority. The sole
determination of which line is active is the
weighting level, thus where if both are equal, which
ever line becomes active remains active until an
error condition occurs.
Table entries are created only by the user when they
add/make a line part of a redundancy group. Non-
Redundancy configurations require one of the entries
(primary or secondary) to be populated. It is
possible to have a redundancy group entry with both
fields not configured (0), however, the state must be
Admin down for this group. Activation requests in
this state will cause an error return."
::= { zhoneInterfaceGroup 3 }
-- Collection of variables describing a pair of lines. One
-- Line is a primary and one is a secondary. In the case
-- where both are actually equivalent, we assign them equal
-- weights, otherwise the primary is given a larger weight than
-- the secondary. The GroupAdminStatus is used to lock the group
-- against changes when modifying an associated line profile,
-- or changing line profiles.
lineGroupEntry OBJECT-TYPE
SYNTAX LineGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A line group entry describes a pair of redundant
lines."
INDEX { lgId }
::= { lineGroupTable 1 }
LineGroupEntry ::=
SEQUENCE {
lgId
Integer32,
lgName
ZhoneAdminString,
lgPrimaryLineId
InterfaceIndexOrZero,
lgPrimaryWeight
Integer32,
lgSecondaryLineId
InterfaceIndexOrZero,
lgSecondaryWeight
Integer32,
lgGroupAdminState
INTEGER,
lgGroupOperState
INTEGER,
lgActiveLineId
InterfaceIndex,
lgRowStatus
ZhoneRowStatus
}
lgId OBJECT-TYPE
SYNTAX Integer32 (1..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The line group entry id. This is a unique number
that is obtained by the nextLineGroupId field.
The range for lgId is 1..2147483647 and the range
for nextLineGroupId is 0..2147483647 where the
value 0 indicates that no unassigned entries are
available."
::= { lineGroupEntry 1 }
lgName OBJECT-TYPE
SYNTAX ZhoneAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name of this entry. This value is the one
utilized by the user when referencing this line group.
This is performed so the user does not have to know
the numeric id's that has been assigned to this group
entry. Because of this, this value is unique within
the line group table and must never be null.
Changing this name is not allowed unless any
references to it are deleted in any associated
records (i.e. subscriber mib).
Required by row creation."
::= { lineGroupEntry 2 }
lgPrimaryLineId OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The id entered in the line profile table for the
profile of the primary line. The default value of
0 indicates no primary line is configured.
When this field is set, the matching lineProfile
entry will also be updated. Note that the matching
entry (ifIndex) must be admin'd down before this
field can be modified.
Required by row creation."
DEFVAL { 0 }
::= { lineGroupEntry 3 }
--
lgPrimaryWeight OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The preference for this line to be active. A value of
1 is low preference, and 10 is high. Default is 5 to
match the secondary line so the default is that both
lines are equal and whichever becomes active first
remains the active line until an error condition
occurs.
Value of 0 is reserved."
DEFVAL { 5 }
::= { lineGroupEntry 4 }
--
lgSecondaryLineId OBJECT-TYPE
SYNTAX InterfaceIndexOrZero
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The name as entered in the line profile table for the
profile of the secondary line. The default value of
0 indicates that no secondary line is configured.
When this field is set, the matching lineProfile
entry will also be updated. Note that the matching
entry (ifIndex) must be admin'd down before this
field can be modified."
DEFVAL { 0 }
::= { lineGroupEntry 5 }
lgSecondaryWeight OBJECT-TYPE
SYNTAX Integer32 (0..10)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The preference for this line to be active. A value of
1 is low preference, and 10 is high. Default is 5 to
match the primary line so that the default is that
both lines are equal and whichever line becomes
active first remains the active line until an error
condition occurs.
Value of 0 is reserved."
DEFVAL { 5 }
::= { lineGroupEntry 6 }
--
lgGroupAdminState OBJECT-TYPE
SYNTAX INTEGER
{
down(1),
up(2),
lockActive(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The line group admin status
- 'up' status is when the group is in use and the
lines in the group can become active. In this state,
line parameters may not be changed.
- 'down' status is set to down the entire line group.
A redundant switch does not occur and in the down
state line group parameters may be cahnged and the
entire line group may be deleted.
- 'lockAtive' status is set to allow the inactive
member of the line group to be modified. In this
state the active line is uneffected, however, if an
error occurs on the active line that would result
in a redundant switch, the switch will not occur."
DEFVAL { down }
::= { lineGroupEntry 7 }
lgGroupOperState OBJECT-TYPE
SYNTAX INTEGER
{
inactive(1),
active(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The state of this line group. Normally, this state
will match the admin state of this group except
during the activation phase of the group or if
'all' active lines in the group are down (admin'd or
due to a fault)
- 'inactive' status is returned when the line group
is not active or inoperable.
- 'active' status is returned if at least one line
is active and operational in the group."
::= { lineGroupEntry 8 }
lgActiveLineId OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The currently active line (ifindex) for this Group.
0 indicates no active lines."
::= { lineGroupEntry 9 }
lgRowStatus OBJECT-TYPE
SYNTAX ZhoneRowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A line group entry can only be created if both the
lgName and line group id is specified.
An entry in this table CANNOT be deleted unless the
admin state is down and both the primary and
secondary line id fields are 0 (no lines are part of
this group).
lgName, lgPrimaryLineId, and lgPrimaryWeight are
required for row creation."
::= { lineGroupEntry 10 }
END
--