NTNTECH-CHASSIS-CONFIGURATION-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- ****************************************************************
|
|
-- Enterprise:
|
|
-- Paradyne Corporation.
|
|
--
|
|
-- ContactInfo:
|
|
-- Paradyne Corporation
|
|
-- 8545 126th Avenue North
|
|
-- Largo, FL 33773
|
|
-- phone: +1 (727) 530 2000
|
|
-- email: support@paradyne.com
|
|
-- www: http://www.nettonet.com/support/
|
|
--
|
|
-- Description:
|
|
-- ntntech-chassis-configuration-MIB.my
|
|
-- Revision: 1.02.02
|
|
-- Part Number: xx-xxxx-xx
|
|
-- Date: November 17, 2004
|
|
--
|
|
-- This module provides explicit definitions for the Net to
|
|
-- Net Technologies naming tree below:
|
|
--
|
|
-- nettonettech { enterprises 8059 }
|
|
--
|
|
-- This module will be extended, as additional sub-sections
|
|
-- of this naming tree are defined.
|
|
--
|
|
-- Disclaimer:
|
|
-- This is an extremely preliminary MIB module and is subject
|
|
-- to change at any time therefore, use at your own risk.
|
|
--
|
|
-- Copyright (c) 2000 - 2004 by Paradyne Corporation.
|
|
-- All rights reserved.
|
|
|
|
-- ****************************************************************
|
|
IMPORTS
|
|
ntntechChassis,NtnDefaultGateway,NtnSubnetMask,NtnTimeTicks,
|
|
NtnDisplayString FROM NTNTECH-ROOT-MIB
|
|
OBJECT-TYPE, MODULE-IDENTITY,IpAddress FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION FROM SNMPv2-TC;
|
|
-- ****************************************************************
|
|
ntntechChassisConfigurationMIB MODULE-IDENTITY
|
|
LAST-UPDATED "0411170200Z" -- November 17, 2004
|
|
ORGANIZATION "Paradyne Corporation"
|
|
CONTACT-INFO
|
|
"Paradyne Corporation
|
|
8545 126th Avenue North
|
|
Largo, FL 33773
|
|
|
|
phone: +1 (727) 530 2000
|
|
email: support@paradyne.com
|
|
www: http://www.nettonet.com/support/"
|
|
|
|
DESCRIPTION
|
|
"This mib module defines an SNMP API to manage the Paradyne Corporation's
|
|
DSLAM chassis parameters. These parameter settings are specifically associated
|
|
with the the MUM200-2 and MUM2000-2 modules and the Mini and Micro DSLAMs.
|
|
The interface types are described below,
|
|
|
|
|
|
AMD8000-12
|
|
12-Port ADSL Mini DSLAMs With Full Rate and G.lite Operational Modes
|
|
|
|
SMD2000-12, SMD2000Q-12, SMD2000G-12
|
|
12-Port SDSL Mini DSLAMs: AC and DC Versions with Cap, 2B1Q
|
|
and G.SHDSL line encoding
|
|
|
|
SuD2011_12T, SuD2011_12E, SuD2003_12T, SuD2003_12E
|
|
12-Port SDSL Micro DSLAMs: Cap, 2B1Q and G.SHDSL line encoding
|
|
|
|
SuD2011_6T, SuD2011_6E, SuD2002_6T, SuD2002_6E
|
|
6-Port SDSL Micro DSLAMs: Cap, 2B1Q and G.SHDSL line encoding
|
|
|
|
MUM200-2, MUM2000-2
|
|
Multiplexer Uplink Module with Dual Uplink Interface Module Capacity
|
|
|
|
UIM-10/100
|
|
Uplink Interface Module
|
|
|
|
UIM-DS3
|
|
DS3 Uplink Interface Module
|
|
|
|
UIM-E1
|
|
E1 Uplink Interface Module
|
|
|
|
UIM-E3
|
|
E3 Uplink Interface Module
|
|
|
|
UIM-T1
|
|
T1 Uplink Interface Module "
|
|
|
|
REVISION "0208131112Z"
|
|
DESCRIPTION
|
|
"Added the mumCfgAdvanced OID.
|
|
Added the mumCfgManagementPort OID."
|
|
|
|
REVISION "0208280912Z"
|
|
DESCRIPTION
|
|
"New Release - v1.01.00"
|
|
|
|
REVISION "0210110913Z"
|
|
DESCRIPTION
|
|
"Added OID mgmtPortCfgType to the mgmtPortCfgTable."
|
|
|
|
REVISION "0210220200Z"
|
|
DESCRIPTION
|
|
"New Release - v1.01.01"
|
|
|
|
REVISION "0211041258Z"
|
|
DESCRIPTION
|
|
"Added the values uplink3(4), uplink4(5), and mgmt(6) to the mumCfgInterConnection
|
|
OID."
|
|
|
|
REVISION "0403151015Z"
|
|
DESCRIPTION
|
|
"Added OID mumCfgCommitChange to the mumCfgTable."
|
|
|
|
REVISION "0404271116Z"
|
|
DESCRIPTION
|
|
"Updated the description associated with the mumCfgCommitChange OID."
|
|
|
|
REVISION "0410110909Z"
|
|
DESCRIPTION
|
|
"Updated the description associated with the mumCfgCommitChange OID again. Adjusted
|
|
the copyright date and references to Paradyne."
|
|
|
|
REVISION "0411170958Z"
|
|
DESCRIPTION
|
|
"New Release -- version 1.02.01"
|
|
|
|
::= { ntntechChassis 1 }
|
|
|
|
|
|
-- Objects
|
|
|
|
chsCfgMIBObjects OBJECT IDENTIFIER ::= { ntntechChassisConfigurationMIB 1 }
|
|
|
|
-- NTNTECH Chassis Configuration (chsCfg) MIB objects for MUM200/2000 modules
|
|
-- or Mini and Micro DSLAMs.
|
|
|
|
chsCfgParameterConfiguration OBJECT IDENTIFIER ::= { chsCfgMIBObjects 1 }
|
|
|
|
-- NTNTECH Chassis Configuration (chsCfg) Parameter Configuration for MUM200/2000 modules
|
|
-- or Mini and Micro DSLAMs.
|
|
--
|
|
-- IPD12000 - slots 13,14 MIB index - 1,2 respecitively
|
|
-- IPD4000 - slot 5 MIB index - 1
|
|
-- Mini DSLAM - NA MIB index - 1
|
|
-- Micro DSLAM - NA MIB index - 1
|
|
--
|
|
|
|
prmCfgMultiplexerUplinkModule OBJECT IDENTIFIER ::= { chsCfgParameterConfiguration 1 }
|
|
|
|
mumCfgNotes OBJECT-TYPE
|
|
SYNTAX NtnDisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis system 'Notes' field is to be used as a scratchpad
|
|
(i.e. chassis id or name) by the administrator. The default value is blank.
|
|
The length of string must not exceed 128 alpha-numeric characters."
|
|
::= { prmCfgMultiplexerUplinkModule 1 }
|
|
|
|
mumCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MumCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of MUM200-2/2000-2 module or Mini/Micro DSLAM entries."
|
|
::= { prmCfgMultiplexerUplinkModule 2 }
|
|
|
|
mumCfgEntry OBJECT-TYPE
|
|
SYNTAX MumCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing management information applicable to a MUM200-2/MUM2000-2
|
|
module or Mini/Micro DSLAM."
|
|
INDEX { mumCfgIndex }
|
|
::= { mumCfgTable 1 }
|
|
|
|
MumCfgEntry ::=
|
|
SEQUENCE {
|
|
mumCfgIndex INTEGER,
|
|
mumCfgIpAddress IpAddress,
|
|
mumCfgSubnetMask IpAddress,
|
|
mumCfgDefaultGateway IpAddress,
|
|
mumCfgInbandMgmt INTEGER,
|
|
mumCfgInbandMGMTVlanID INTEGER,
|
|
mumCfgInterConnection INTEGER,
|
|
mumCfgCommitChange INTEGER
|
|
}
|
|
|
|
mumCfgIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Translates to the physical slot number that a MUM200-2/2000-2 module
|
|
exists within a chassis. The Mini/Micro DSLAMs' physical location is
|
|
set to 1 by default. See below,
|
|
|
|
chassis type physical location(s) translation
|
|
------------ --------------------------------
|
|
IPD12000 MUM in slots 13,14 = mumCfgIndex 1,2 respecitively
|
|
IPD4000 MUM in slot 5 = mumCfgIndex 1
|
|
Mini DSLAM NA = mumCfgIndex 1
|
|
Micro DSLAM NA = mumCfgIndex 1"
|
|
::= { mumCfgEntry 1 }
|
|
|
|
mumCfgIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address assigned to a MUM200-2/2000-2 module or Mini/Micro DSLAM.
|
|
This parameter is initially set to a default value, i.e 192.168.254.252
|
|
for a MUM200-2/2000-2 module located in slot 13 of an IPD12000, slot 5
|
|
of an IPD4000 DSLAM and a Mini/Micro DSLAM. The default value of
|
|
192.168.254.253 will be for a MUM200-2/2000-2 module located in slot 14 of
|
|
an IPD12000 (duplicate IP addresses are not allowed). These default
|
|
values can be modified by the user."
|
|
::= { mumCfgEntry 2 }
|
|
|
|
mumCfgSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Subnet Mask assigned to a MUM200-2/2000-2 module or Mini/Micro DSLAM.
|
|
This parameter is assiged by the user, the default value is 255.255.255.0."
|
|
::= { mumCfgEntry 3 }
|
|
|
|
mumCfgDefaultGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Default Gateway assigned to a MUM200-2/2000-2 module or Mini/Micro DSLAM.
|
|
This value is assiged by the user, the default value is 0.0.0.0."
|
|
::= { mumCfgEntry 4 }
|
|
|
|
mumCfgInbandMgmt OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on(1), -- parameter enabled
|
|
off(2) -- parameter disabled
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inband management feature, when enabled [ON(1)], allows access to the
|
|
DSLAM via the network against an assigned IP address, subnet mask,
|
|
and default gateway."
|
|
::= { mumCfgEntry 5 }
|
|
|
|
mumCfgInbandMGMTVlanID OBJECT-TYPE
|
|
SYNTAX INTEGER (0..4085)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP DSLAM supports 802.1Q Virtual LANs (VLANs). This parameter
|
|
configuration applies to the inband management traffic only.
|
|
|
|
It does not apply to out of band traffic received from the MGMT port.
|
|
|
|
Note: for the case where the chassis type is an IPD12000 loaded with
|
|
two MUMs, the setting of this parameter will affect both."
|
|
::= { mumCfgEntry 6 }
|
|
|
|
mumCfgInterConnection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
neither(1),
|
|
uplink1(2),
|
|
uplink2(3),
|
|
uplink3(4),
|
|
uplink4(5),
|
|
mgmt(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPD12000 or IPD4000 DSLAM interconnect configuration provides the system
|
|
manager the ability to daisy-chain one IP DSLAM to another so that a single
|
|
router may be used for all DSLAMs in the chain."
|
|
::= { mumCfgEntry 7 }
|
|
|
|
mumCfgCommitChange OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled(0), -- do not commit a change
|
|
enabled(1) -- commit a change
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set to enabled(1) in order to commit the latest changes to the IP address, subnetmask,
|
|
default gateway chassis parameters. This is only applicable to the SNE2040G-P and the
|
|
SNE2040G-S."
|
|
::= { mumCfgEntry 8 }
|
|
|
|
|
|
|
|
mumCfgUplinkInterfaceModule OBJECT IDENTIFIER ::= { prmCfgMultiplexerUplinkModule 3 }
|
|
|
|
-- The ethernet table is simply a place holder for future reference.
|
|
|
|
uimCfgEthTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UimCfgEthEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of ethernet Uplink Interface Module (UIM) entries."
|
|
::= { mumCfgUplinkInterfaceModule 1 }
|
|
|
|
uimCfgEthEntry OBJECT-TYPE
|
|
SYNTAX UimCfgEthEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to an ethernet Uplink Interface Module (UIM)."
|
|
INDEX { uimCfgEthMumIndex, uimCfgEthIndex }
|
|
::= { uimCfgEthTable 1 }
|
|
|
|
UimCfgEthEntry ::=
|
|
SEQUENCE {
|
|
uimCfgEthMumIndex INTEGER,
|
|
uimCfgEthIndex INTEGER,
|
|
uimCfgEthRxTxRate INTEGER,
|
|
uimCfgEthDuplex INTEGER
|
|
}
|
|
|
|
uimCfgEthMumIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Translates to the physical slot number that a MUM200-2/2000-2 module
|
|
exists within a chassis. The Mini/Micro DSLAMs' physical location is
|
|
set to 1 by default. See below,
|
|
|
|
chassis type physical location(s) translation
|
|
------------ --------------------------------
|
|
IPD12000 MUM in slots 13,14 = uimCfgEthMumIndex 1,2 respecitively
|
|
IPD4000 MUM in slot 5 = uimCfgEthMumIndex 1
|
|
Mini DSLAM NA = uimCfgEthMumIndex 1
|
|
Micro DSLAM NA = uimCfgEthMumIndex 1
|
|
|
|
Note: when configuring an ethernet UIM, the user must enter the
|
|
index of the MUM, see above table, that corresponds with the
|
|
IP address of the remote SNMP agent."
|
|
::= { uimCfgEthEntry 1 }
|
|
|
|
uimCfgEthIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical slot used to access the UIM in the MUM200-2/2000-2 module or
|
|
Mini/Micro DSLAM."
|
|
::= { uimCfgEthEntry 2 }
|
|
|
|
uimCfgEthRxTxRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimEthAutoNegotiate(0),
|
|
uimEth10(1),
|
|
uimEth100(2),
|
|
uimEthGig(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The RxTx rate for an ethernet UIM."
|
|
::= { uimCfgEthEntry 3 }
|
|
|
|
uimCfgEthDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimEthAutoNegotiate(0),
|
|
uimEthHalf(1),
|
|
uimEthFull(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current duplex setting for an ethernet UIM."
|
|
::= { uimCfgEthEntry 4 }
|
|
|
|
|
|
uimCfgT1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UimCfgT1Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of T1 Uplink Interface Module (UIM) entries."
|
|
::= { mumCfgUplinkInterfaceModule 2 }
|
|
|
|
uimCfgT1Entry OBJECT-TYPE
|
|
SYNTAX UimCfgT1Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to a T1 Uplink Interface Module (UIM)."
|
|
INDEX { uimCfgT1MumIndex, uimCfgT1Index }
|
|
::= { uimCfgT1Table 1 }
|
|
|
|
UimCfgT1Entry ::=
|
|
SEQUENCE {
|
|
uimCfgT1MumIndex INTEGER,
|
|
uimCfgT1Index INTEGER,
|
|
uimCfgT1Frame INTEGER,
|
|
uimCfgT1LineCode INTEGER,
|
|
uimCfgT1LineBuildout INTEGER
|
|
}
|
|
|
|
uimCfgT1MumIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Translates to the physical slot number that a MUM200-2/2000-2 module
|
|
exists within a chassis. The Mini/Micro DSLAMs' physical location is
|
|
set to 1 by default. See below,
|
|
|
|
chassis type physical location(s) translation
|
|
------------ --------------------------------
|
|
IPD12000 MUM in slots 13,14 = uimCfgT1MumIndex 1,2 respecitively
|
|
IPD4000 MUM in slot 5 = uimCfgT1MumIndex 1
|
|
Mini DSLAM NA = uimCfgT1MumIndex 1
|
|
Micro DSLAM NA = uimCfgT1MumIndex 1
|
|
|
|
|
|
Note: when configuring a T1 UIM, the user must enter the
|
|
index of the MUM, see above table, that corresponds with the
|
|
IP address of the remote SNMP agent."
|
|
::= { uimCfgT1Entry 1 }
|
|
|
|
uimCfgT1Index OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical slot used to access the UIM in the MUM200-2/2000-2 module or
|
|
Mini/Micro DSLAM."
|
|
::= { uimCfgT1Entry 2 }
|
|
|
|
uimCfgT1Frame OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimT1ESF(1),
|
|
uimT1SFD4(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The frame type parameter for a T1 UIM."
|
|
::= { uimCfgT1Entry 3 }
|
|
|
|
uimCfgT1LineCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimT1B8ZS(1),
|
|
uimT1AMI(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line code parameter for a T1 UIM."
|
|
::= { uimCfgT1Entry 4 }
|
|
|
|
uimCfgT1LineBuildout OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimT10db(1),
|
|
uimT1N7p5db(2),
|
|
uimT1N15db(3),
|
|
uimT1N22p5db(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line buildout parameter for a T1 UIM."
|
|
::= { uimCfgT1Entry 5 }
|
|
|
|
uimCfgE1Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF UimCfgE1Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of E1 Uplink Interface Module (UIM) entries."
|
|
::= { mumCfgUplinkInterfaceModule 3 }
|
|
|
|
uimCfgE1Entry OBJECT-TYPE
|
|
SYNTAX UimCfgE1Entry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to an E1 Uplink Interface Module (UIM)."
|
|
INDEX { uimCfgE1MumIndex, uimCfgE1Index }
|
|
::= { uimCfgE1Table 1 }
|
|
|
|
UimCfgE1Entry ::=
|
|
SEQUENCE {
|
|
uimCfgE1MumIndex INTEGER,
|
|
uimCfgE1Index INTEGER,
|
|
uimCfgE1Frame INTEGER,
|
|
uimCfgE1LineCode INTEGER
|
|
}
|
|
|
|
uimCfgE1MumIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Translates to the physical slot number that a MUM200-2/2000-2 module
|
|
exists within a chassis. The Mini/Micro DSLAMs' physical location is
|
|
set to 1 by default. See below,
|
|
|
|
chassis type physical location(s) translation
|
|
------------ --------------------------------
|
|
IPD12000 MUM in slots 13,14 = uimCfgE1MumIndex 1,2 respecitively
|
|
IPD4000 MUM in slot 5 = uimCfgE1MumIndex 1
|
|
Mini DSLAM NA = uimCfgE1MumIndex 1
|
|
Micro DSLAM NA = uimCfgE1MumIndex 1
|
|
|
|
Note: when configuring an E1 UIM, the user must enter the
|
|
index of the MUM, see above table, that corresponds with the
|
|
IP address of the remote SNMP agent."
|
|
::= { uimCfgE1Entry 1 }
|
|
|
|
uimCfgE1Index OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The physical slot used to access the UIM in the MUM200-2/2000-2 module or
|
|
Mini/Micro DSLAM."
|
|
::= { uimCfgE1Entry 2 }
|
|
|
|
uimCfgE1Frame OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimE1CRC(1),
|
|
uimE1NoCRC(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The frame type parameter for an E1 UIM."
|
|
::= { uimCfgE1Entry 3 }
|
|
|
|
uimCfgE1LineCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimE1HDB3(1),
|
|
uimE1AMI(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The line code parameter for an E1 UIM."
|
|
::= { uimCfgE1Entry 4 }
|
|
|
|
mumSNMPConfiguration OBJECT IDENTIFIER ::= { prmCfgMultiplexerUplinkModule 4 }
|
|
|
|
snmpCfgNoticeIpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SnmpCfgNoticeIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of SNMP trap notification Ip Addresses."
|
|
::= { mumSNMPConfiguration 1 }
|
|
|
|
snmpCfgNoticeIpEntry OBJECT-TYPE
|
|
SYNTAX SnmpCfgNoticeIpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing SNMP information applicable to a MUM200-2/MUM2000-2 module
|
|
or Mini/Micro DSLAM."
|
|
INDEX { snmpCfgNoticeIndex }
|
|
::= { snmpCfgNoticeIpTable 1 }
|
|
|
|
SnmpCfgNoticeIpEntry ::=
|
|
SEQUENCE {
|
|
snmpCfgNoticeIndex INTEGER,
|
|
snmpCfgNoticeIpAddress IpAddress
|
|
}
|
|
|
|
snmpCfgNoticeIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An integer value that points to one of four trap notification IP addresses."
|
|
::= { snmpCfgNoticeIpEntry 1 }
|
|
|
|
snmpCfgNoticeIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Address of the location or computer to which you would like trap
|
|
notifications sent. The default value is 0.0.0.0 and it can be modified
|
|
by the user."
|
|
::= { snmpCfgNoticeIpEntry 2 }
|
|
|
|
snmpCfgAuthenticationTrapState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether Authentication traps should be generated.
|
|
|
|
By default, this object should have the value enabled(1)."
|
|
::= { mumSNMPConfiguration 2 }
|
|
|
|
snmpCfgEnvironmentTrapState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the fan and temperature traps should be generated.
|
|
|
|
By default, this object should have the value enabled(1)."
|
|
::= { mumSNMPConfiguration 3 }
|
|
|
|
snmpCfgColdstartTrapState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether Cold Start traps should be generated.
|
|
|
|
By default, this object should have the value disabled(2)."
|
|
::= { mumSNMPConfiguration 4 }
|
|
|
|
snmpCfgModulePortTrapState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates whether the module present/removed and link up/down traps should be generated.
|
|
|
|
By default, this object should have the value disabled(2)."
|
|
::= { mumSNMPConfiguration 5 }
|
|
|
|
snmpCfgCommunity OBJECT IDENTIFIER ::= { mumSNMPConfiguration 6 }
|
|
|
|
comReadWriteAccess OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..15))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The community string that will allow the user read/write access to the
|
|
agent. In otherwords, the user will be allowed to view and set
|
|
parameter attributes.
|
|
|
|
Note: since this is a hidden attribute, for security purposes, when
|
|
performing a get on this OID the string that is returned will
|
|
be represented by asterisk(s)."
|
|
::= { snmpCfgCommunity 1 }
|
|
|
|
comReadOnlyAccess OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..15))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The community string that will allow the user read access to the
|
|
agent. In otherwords, the user will be allowed to view parameter attributes.
|
|
|
|
Note: since this is a hidden attribute, for security purposes, when
|
|
performing a get on this OID the string that is returned will
|
|
be represented by asterisk(s)."
|
|
::= { snmpCfgCommunity 2 }
|
|
|
|
mumCfgUniques OBJECT IDENTIFIER ::= { prmCfgMultiplexerUplinkModule 5 }
|
|
|
|
unqEmbHttpWebsrvrState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This configuration parameter allows the user the ability to disable, or enable,
|
|
the embedded webserver.
|
|
|
|
By default, this object should have the value enabled(1)."
|
|
::= { mumCfgUniques 1 }
|
|
|
|
mumCfgAdvanced OBJECT IDENTIFIER ::= { prmCfgMultiplexerUplinkModule 6 }
|
|
|
|
advCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AdvCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of the Advanced Configuration entries."
|
|
::= { mumCfgAdvanced 1 }
|
|
|
|
advCfgEntry OBJECT-TYPE
|
|
SYNTAX AdvCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to an Advanced Configuration parameter."
|
|
INDEX { advCfgMumIndex }
|
|
::= { advCfgTable 1 }
|
|
|
|
AdvCfgEntry ::=
|
|
SEQUENCE {
|
|
advCfgMumIndex INTEGER,
|
|
advCfgTFTPState INTEGER,
|
|
advCfgTelnetState INTEGER,
|
|
advCfgMgmtFltrIpStart IpAddress,
|
|
advCfgMgmtFltrIpEnd IpAddress,
|
|
advCfgMgmtSessionTimeout NtnTimeTicks
|
|
}
|
|
|
|
advCfgMumIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Translates to the physical slot number that a MUM200-2/2000-2 module
|
|
exists within a chassis. The Mini/Micro DSLAMs' physical location is
|
|
set to 1 by default. See below,
|
|
|
|
chassis type physical location(s) translation
|
|
------------ --------------------------------
|
|
IPD12000 MUM in slots 13,14 = uimCfgE1MumIndex 1,2 respecitively
|
|
IPD4000 MUM in slot 5 = uimCfgE1MumIndex 1
|
|
Mini DSLAM NA = uimCfgE1MumIndex 1
|
|
Micro DSLAM NA = uimCfgE1MumIndex 1
|
|
|
|
Note: when configuring an Advanced Configuration parameter, the user
|
|
must enter the index of the MUM, see above table, that corresponds
|
|
with the IP address of the remote SNMP agent."
|
|
::= { advCfgEntry 1 }
|
|
|
|
advCfgTFTPState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This configuration parameter allows the user the ability to disable, or enable,
|
|
the TFTP server.
|
|
|
|
By default, this object should have the value enabled(1)."
|
|
::= { advCfgEntry 2 }
|
|
|
|
advCfgTelnetState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enabled(1),
|
|
disabled(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This configuration parameter allows the user the ability to disable, or enable,
|
|
telnet.
|
|
|
|
By default, this object should have the value enabled(1)."
|
|
::= { advCfgEntry 3 }
|
|
|
|
advCfgMgmtFltrIpStart OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The start value for the management IP filter range. This parameter
|
|
is initially set to a default filter range of 0.0.0.0 - 255.255.255.255.
|
|
Connection to the management system will be allowed only if the user's Ip
|
|
address value falls within the defined mumCfgMgmtIpStart and mumCfgMgmtIpEnd
|
|
range."
|
|
::= { advCfgEntry 4 }
|
|
|
|
advCfgMgmtFltrIpEnd OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The end value for the management IP filter range. This parameter
|
|
is initially set to a default filter range of 0.0.0.0 - 255.255.255.255.
|
|
Connection to the management system will be allowed only if the user's Ip
|
|
address value falls within the defined mumCfgMgmtIpStart and mumCfgMgmtIpEnd
|
|
range."
|
|
::= { advCfgEntry 5 }
|
|
|
|
advCfgMgmtSessionTimeout OBJECT-TYPE
|
|
SYNTAX NtnTimeTicks
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value defines the length of a password session in seconds. If the
|
|
session has been idle for a time greater than this value, the browser will
|
|
be challenged again, even if it has provided authentication credentials
|
|
with the request."
|
|
::= { advCfgEntry 6 }
|
|
|
|
mumCfgManagementPort OBJECT IDENTIFIER ::= { prmCfgMultiplexerUplinkModule 7 }
|
|
|
|
mgmtPortCfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MgmtPortCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A list of the hardware platform management port entries."
|
|
::= { mumCfgManagementPort 1 }
|
|
|
|
mgmtPortCfgEntry OBJECT-TYPE
|
|
SYNTAX MgmtPortCfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry containing information applicable to the managment (ethernet type) port."
|
|
INDEX { mgmtPortCfgMumIndex }
|
|
::= { mgmtPortCfgTable 1 }
|
|
|
|
MgmtPortCfgEntry ::=
|
|
SEQUENCE {
|
|
mgmtPortCfgMumIndex INTEGER,
|
|
mgmtPortCfgRxTxRate INTEGER,
|
|
mgmtPortCfgDuplex INTEGER,
|
|
mgmtPortCfgType INTEGER
|
|
}
|
|
|
|
mgmtPortCfgMumIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Translates to the physical slot number that a MUM200-2/2000-2 module
|
|
exists within a chassis. The Mini/Micro DSLAMs' physical location is
|
|
set to 1 by default. See below,
|
|
|
|
chassis type physical location(s) translation
|
|
------------ --------------------------------
|
|
IPD12000 MUM in slots 13,14 = uimCfgEthMumIndex 1,2 respecitively
|
|
IPD4000 MUM in slot 5 = uimCfgEthMumIndex 1
|
|
Mini DSLAM NA = uimCfgEthMumIndex 1
|
|
Micro DSLAM NA = uimCfgEthMumIndex 1
|
|
|
|
Note: when configuring a management port, the user must enter the
|
|
index of the MUM, see above table, that corresponds with the
|
|
IP address of the remote SNMP agent."
|
|
::= { mgmtPortCfgEntry 1 }
|
|
|
|
mgmtPortCfgRxTxRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimEthAutoNegotiate(0),
|
|
uimEth10(1),
|
|
uimEth100(2),
|
|
uimEthGig(3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set the RxTx rate for an ethernet management port."
|
|
::= { mgmtPortCfgEntry 2 }
|
|
|
|
mgmtPortCfgDuplex OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
uimEthAutoNegotiate(0),
|
|
uimEthHalf(1),
|
|
uimEthFull(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set the duplex setting for an ethernet management port."
|
|
::= { mgmtPortCfgEntry 3 }
|
|
|
|
mgmtPortCfgType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
mgmt(1),
|
|
uplink(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Set the management port type as follows. By setting this
|
|
port to mgmt(1), it will operate as a non-bridge mode connection.
|
|
Setting it to uplink(2), this port will operate like an uplink
|
|
interface module, i.e. a bridge mode connection.
|
|
|
|
Note: this applies to the AuD8000-12 micro DSLAM only."
|
|
::= { mgmtPortCfgEntry 4 }
|
|
|
|
END
|