36938 lines
1.5 MiB

--
-- Version: 7.04.05
-- Date of Last Update: 2/18/2010
-- Modified by: Richard King (since 5/2005)
-- Fourth Author: Wai Tai (12/2001 to 6/2004)
-- Third Author: Srinivas Tummala (6/2001 to 11/2001)
-- Second Author: Wai Tai (since 4/2000 to 5/2001)
-- Original Author: Rasta A. Mansour (9/1999)
--
-- Description: This MIB describes the manageable elements for the
-- LuxN optical fiber transmission product. This MIB
-- is based on SNMPv1 MIB-2 specification.
--
-- Copyright (c) 2001 to 2003 - LuxN, Inc.
-- All Rights Reserved
--
-- History of Changes:
--
LUXN-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, Counter,
Gauge, IpAddress FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215;
-- Full OID: iso org(3) dod(6) internet(1) private(4)
-- enterprises (1) 1.3.6.1.4.1.4253
luxN OBJECT IDENTIFIER ::= { enterprises 4253 }
-- groups in luxN mib
configuration OBJECT IDENTIFIER ::= { luxN 1 }
performance OBJECT IDENTIFIER ::= { luxN 2 }
faults OBJECT IDENTIFIER ::= { luxN 3 }
security OBJECT IDENTIFIER ::= { luxN 4 }
accounting OBJECT IDENTIFIER ::= { luxN 5 }
-- subgroups in the configuration group
manufacturing OBJECT IDENTIFIER ::= { configuration 1 }
cp OBJECT IDENTIFIER ::= { configuration 2 }
cc OBJECT IDENTIFIER ::= { configuration 3 }
mux OBJECT IDENTIFIER ::= { configuration 4 }
ps OBJECT IDENTIFIER ::= { configuration 5 }
download OBJECT IDENTIFIER ::= { configuration 6 }
fadm OBJECT IDENTIFIER ::= { configuration 7 }
oppm OBJECT IDENTIFIER ::= { configuration 8 }
mcm OBJECT IDENTIFIER ::= { configuration 9 }
fn OBJECT IDENTIFIER ::= { configuration 10 }
csim OBJECT IDENTIFIER ::= { configuration 11 }
rpsm OBJECT IDENTIFIER ::= { configuration 12 }
rsdm OBJECT IDENTIFIER ::= { configuration 13 }
rtdm OBJECT IDENTIFIER ::= { configuration 14 }
osam OBJECT IDENTIFIER ::= { configuration 15 }
rsm OBJECT IDENTIFIER ::= { configuration 16 }
upsm OBJECT IDENTIFIER ::= { configuration 17 }
mcmesc OBJECT IDENTIFIER ::= { configuration 18 }
systemConfig OBJECT IDENTIFIER ::= { configuration 21 }
topology OBJECT IDENTIFIER ::= { configuration 22 }
routing OBJECT IDENTIFIER ::= { configuration 23 }
ring OBJECT IDENTIFIER ::= { configuration 24 }
tap OBJECT IDENTIFIER ::= { configuration 25 }
voadm OBJECT IDENTIFIER ::= { configuration 26 }
zmsConfigSync OBJECT IDENTIFIER ::= { configuration 27 }
dmm OBJECT IDENTIFIER ::= { configuration 28 }
ocm10gf OBJECT IDENTIFIER ::= { configuration 29 }
ocm2 OBJECT IDENTIFIER ::= { configuration 30 }
osc OBJECT IDENTIFIER ::= { configuration 31 }
ocm4g OBJECT IDENTIFIER ::= { configuration 32 }
oet OBJECT IDENTIFIER ::= { configuration 33 }
uob OBJECT IDENTIFIER ::= { configuration 34 }
fc8g OBJECT IDENTIFIER ::= { configuration 35 }
-- subgroups of the performance group
current1 OBJECT IDENTIFIER ::= { performance 1 }
historical OBJECT IDENTIFIER ::= { performance 2 }
specialConditions OBJECT IDENTIFIER ::= { performance 3 }
-- subgroups of the current subgroup
systemPerf OBJECT IDENTIFIER ::= { current1 1 }
downloadPerf OBJECT IDENTIFIER ::= { current1 2 }
cpPerf OBJECT IDENTIFIER ::= { current1 3 }
ccPerf OBJECT IDENTIFIER ::= { current1 4 }
muxPerf OBJECT IDENTIFIER ::= { current1 5 }
psPerf OBJECT IDENTIFIER ::= { current1 6 }
fadmPerf OBJECT IDENTIFIER ::= { current1 7 }
oppmPerf OBJECT IDENTIFIER ::= { current1 8 }
mcmPerf OBJECT IDENTIFIER ::= { current1 9 }
fnPerf OBJECT IDENTIFIER ::= { current1 10 }
csimPerf OBJECT IDENTIFIER ::= { current1 11 }
rpsmPerf OBJECT IDENTIFIER ::= { current1 12 }
rsdmPerf OBJECT IDENTIFIER ::= { current1 13 }
rtdmPerf OBJECT IDENTIFIER ::= { current1 14 }
osamPerf OBJECT IDENTIFIER ::= { current1 15 }
rsmPerf OBJECT IDENTIFIER ::= { current1 16 }
upsmPerf OBJECT IDENTIFIER ::= { current1 17 }
mcmescPerf OBJECT IDENTIFIER ::= { current1 18 }
routingPerf OBJECT IDENTIFIER ::= { current1 21 }
tapPerf OBJECT IDENTIFIER ::= { current1 22 }
voadmPerf OBJECT IDENTIFIER ::= { current1 23 }
dmmPerf OBJECT IDENTIFIER ::= { current1 24 }
ocm10gfPerf OBJECT IDENTIFIER ::= { current1 25 }
ocm2Perf OBJECT IDENTIFIER ::= { current1 26 }
oscPerf OBJECT IDENTIFIER ::= { current1 27 }
ocm4gPerf OBJECT IDENTIFIER ::= { current1 28 }
oetPerf OBJECT IDENTIFIER ::= { current1 29 }
uobPerf OBJECT IDENTIFIER ::= { current1 30 }
fc8gPerf OBJECT IDENTIFIER ::= { current1 31 }
-- subgroups of the historical subgroup
systemHist OBJECT IDENTIFIER ::= { historical 1 }
downloadHist OBJECT IDENTIFIER ::= { historical 2 }
cpHist OBJECT IDENTIFIER ::= { historical 3 }
ccHist OBJECT IDENTIFIER ::= { historical 4 }
muxHist OBJECT IDENTIFIER ::= { historical 5 }
psHist OBJECT IDENTIFIER ::= { historical 6 }
fadmHist OBJECT IDENTIFIER ::= { historical 7 }
oppmHist OBJECT IDENTIFIER ::= { historical 8 }
mcmHist OBJECT IDENTIFIER ::= { historical 9 }
fnHist OBJECT IDENTIFIER ::= { historical 10 }
csimHist OBJECT IDENTIFIER ::= { historical 11 }
rpsmHist OBJECT IDENTIFIER ::= { historical 12 }
rsdmHist OBJECT IDENTIFIER ::= { historical 13 }
rtdmHist OBJECT IDENTIFIER ::= { historical 14 }
osamHist OBJECT IDENTIFIER ::= { historical 15 }
rsmHist OBJECT IDENTIFIER ::= { historical 16 }
upsmHist OBJECT IDENTIFIER ::= { historical 17 }
mcmescHist OBJECT IDENTIFIER ::= { historical 18 }
tapHist OBJECT IDENTIFIER ::= { historical 19 }
voadmHist OBJECT IDENTIFIER ::= { historical 20 }
dmmHist OBJECT IDENTIFIER ::= { historical 21 }
ocm10gfHist OBJECT IDENTIFIER ::= { historical 22 }
ocm2Hist OBJECT IDENTIFIER ::= { historical 23 }
oscHist OBJECT IDENTIFIER ::= { historical 24 }
ocm4gHist OBJECT IDENTIFIER ::= { historical 25 }
oetHist OBJECT IDENTIFIER ::= { historical 26 }
uobHist OBJECT IDENTIFIER ::= { historical 27 }
-- subgroups of the specialConditions subgroup
systemCond OBJECT IDENTIFIER ::= { specialConditions 1 }
downloadCond OBJECT IDENTIFIER ::= { specialConditions 2 }
cpCond OBJECT IDENTIFIER ::= { specialConditions 3 }
ccCond OBJECT IDENTIFIER ::= { specialConditions 4 }
muxCond OBJECT IDENTIFIER ::= { specialConditions 5 }
psCond OBJECT IDENTIFIER ::= { specialConditions 6 }
fadmCond OBJECT IDENTIFIER ::= { specialConditions 7 }
oppmCond OBJECT IDENTIFIER ::= { specialConditions 8 }
mcmCond OBJECT IDENTIFIER ::= { specialConditions 9 }
fnCond OBJECT IDENTIFIER ::= { specialConditions 10 }
rpsmCond OBJECT IDENTIFIER ::= { specialConditions 12 }
rsdmCond OBJECT IDENTIFIER ::= { specialConditions 13 }
rtdmCond OBJECT IDENTIFIER ::= { specialConditions 14 }
osamCond OBJECT IDENTIFIER ::= { specialConditions 15 }
rsmCond OBJECT IDENTIFIER ::= { specialConditions 16 }
upsmCond OBJECT IDENTIFIER ::= { specialConditions 17 }
-- subgroups of the faults group
eventLog OBJECT IDENTIFIER ::= { faults 1 }
userLog OBJECT IDENTIFIER ::= { faults 2 }
diagnostics OBJECT IDENTIFIER ::= { faults 3 }
alarmLog OBJECT IDENTIFIER ::= { faults 4 }
-- subgroups of the diagnostics group
diagSelfTest OBJECT IDENTIFIER ::= { diagnostics 5 }
-- subgroups of the diagSelfTest group
mcmescSelfTest OBJECT IDENTIFIER ::= { diagSelfTest 1 }
-- place holder here for other module's self test in the future:
-- newModuleSelfTest OBJECT IDENTIFIER ::= { diagSelfTest 2 }
-- subgroups of the security group
userSecMgmt OBJECT IDENTIFIER ::= { security 1 }
systemSecMgmt OBJECT IDENTIFIER ::= { security 2 }
netSecMgmt OBJECT IDENTIFIER ::= { security 3 }
-- subgroups of the security group
radiusSecMgmt OBJECT IDENTIFIER ::= { netSecMgmt 1 }
sshSecMgmt OBJECT IDENTIFIER ::= { netSecMgmt 2 }
-- subgroups of the accounting group
cpAcct OBJECT IDENTIFIER ::= { accounting 1 }
ccAcct OBJECT IDENTIFIER ::= { accounting 2 }
mcmAcct OBJECT IDENTIFIER ::= { accounting 3 }
mcmescAcct OBJECT IDENTIFIER ::= { accounting 4 }
--
-- Global Data types
--
-- Textual conventions for the FlagType data type
--
-- on means enabled
-- off means disabled
--
FlagType ::= INTEGER { on(1), off(2) }
--
-- Global Data types
--
-- Textual conventions for the ResetType data type
--
-- Other is used for only get purpose
-- Reset means set the flag to OFF or FALSE or whatever
-- means reset
ResetType ::= INTEGER { other(1), reset(2) }
-- Textual conventions for the RebootType data type
--
-- Other is used for only get purpose
-- warmboot means to reboot the particular card chosen
--
RebootType ::= INTEGER { other(1), warmboot(2) }
-- Textual conventions for the Boolean data type
--
-- True or 'Y' is 1, False or 'N' is 2
--
Boolean ::= INTEGER { true(1), false(2) }
-- Textual conventions for the ChassisType data type
ChassisType ::= INTEGER { wavstation1(1), gm3234(2), gm3217(3), gm1602(4), gm1608(5), gmx128(6) }
-- Textual conventions for the CardLocation data type
--
-- 1 means local, 2 means remote link 1, 3 means remote link 2
--
CardLocation ::= INTEGER { local(1), remote1(2), remote2(3) }
-- Textual conventions for the CardShelf data type
--
-- There could be up to 2 shelves per Chassis
--
CardShelf ::= INTEGER (1..2)
-- Textual conventions for the CardSlot data type
--
-- There could be up to 17 card slots per shelf
--
CardSlot ::= INTEGER (1..17)
-- Textual conventions for the ShelfInput data type
--
ShelfInput ::= INTEGER (0..2)
-- Textual conventions for the SlotInput data type
--
SlotInput ::= INTEGER (0..17)
-- Textual conventions for the CardName data type
--
-- Card name may be any alpha-numeric character string
-- up to 32 characters.
CardName ::= DisplayString (SIZE (0..32))
-- Textual conventions for the LinkName data type
--
-- Link name may be any alpha-numeric character string
-- up to 40 characters.
LinkName ::= DisplayString (SIZE (0..40))
-- Textual conventions for the CardType data type
--
-- There could be up to 20 different card type
--
CardType ::= INTEGER
{
empty(0),
mpm(1),
ocmu(2),
ocmi(3),
ofcm(4),
ofcd(5),
fadm(6),
oppm(7),
mcmt1(8),
oli(9),
w4cd(10),
w2cmd(13),
osam(20),
w4cm(21),
rsm(22),
upsm(23),
ocme(24),
oci(25),
oxc(26),
ocm10g(27),
osamlp(29),
osamhp(30),
mcmesc(33),
wfadm(34),
mcme1(35),
md100-1(36),
md100-40(37),
tap(38),
md100-5(39),
md100-10(40),
ocm10glr(41),
bd-4(42),
bp-10(43),
unknown(44),
dmm(45),
bp-5(46),
mpm2(47),
osc(48),
ocm2(49),
ocm10gf(50),
ocm2-4g(51),
oet(52),
uob(53),
fc8g(54),
md100p(55),
cwdm_bd4(56)
}
-- Textual conventions for the CardStatus data type
--
-- The status' are: Critical, Major, Minor, and Normal.
--
-- Critical means that the device is experiencing a
-- service outage.
-- Major means that a service affecting fault exists.
-- Minor means that a fault exists but it is not service
-- affecting.
-- Normal means all is well and the card is functioning
-- acknowledged means that a fault of critical minor or major severity exists
-- and is acknowledged by the user!
-- properly.
--
CardStatus ::= INTEGER { critical(1), major(2), minor(3), normal(4), acknowledged(5) }
-- Textual conventions for the CardState data type
--
-- The states are: online, offline, empty, loopback, diag
--
-- online means the card is in the slot and working.
-- offline means the card is in the slot but currently
-- not working.
-- empty means that the slot is empty (no card)
-- loopback means the card is put in the loopback mode.
-- diag means the card is put in the diagnostic test mode.
--
CardState ::= INTEGER { empty(1), online(2), offline(3), loopback(4), diag(5) }
-- Textual conventions for the RedundancyMode data type
--
-- Several cards, like CP or PS can have a redundant pair.
-- This data type is used to indicate the state of those cards.
--
RedundancyMode ::= INTEGER { active(1), standby(2) }
-- Textual conventions for the Node Name data type
-- Node name may be any alpha-numeric character string
-- up to 32 characters.
NodeName ::= DisplayString(SIZE(0..32))
-- Textual conventions for the Port Index data type
-- There could be up 16 ports per card
--
PortIndex ::= INTEGER(1..16)
-- Textual conventions for the CardCycleMode data type
--
-- Each card can be cycled according to the following modes:
--
-- Request the card to be coldbooted (full initialization).
-- Request the card to be warmbooted (new executable software loaded)
-- Request the card to go offline
-- Request the card to come back online
-- Request the card to go into loopback mode
-- Request the card to go into diagnostic mode
--
CardCycleMode ::= INTEGER { coldboot(1), warmboot(2), offline(3), online(4), loopback(5), diag(6) }
-- Textual conventions for the TrapStatus data type
--
-- The status' are: Critical, Major, Minor, Normal, and Clear.
--
-- Critical means that the device is experiencing a service outage.
-- Major means that a service affecting fault exists.
-- Minor means that a fault exists but it is not service affecting.
-- Normal means all is well and the card is functioning properly.
-- This trap status is treated as informational.
-- Clear means that all previous alarms are cleared, and the
-- current system status is Normal.
--
TrapStatus ::= INTEGER { critical(1), major(2), minor(3), normal(4), clear(5) }
-- Textual conventions for the CardState data type
-- Textual conventions for the HistoryMode data type
--
-- Two types of historical counters are maintained. One counter is
-- the daily counter set. It aggregates the 15 minute performance
-- counters into one daily sum counter. At the end of the day,
-- this counter is reset. The second counter is the perpetual
-- longterm counter. This counter aggregates the 15 minute
-- performance counters for an indefinite amount of time. When
-- the counter exceeds the maximum value, it will wrap around.
--
HistoryMode ::= INTEGER { daily(1), longterm(2) }
-- Textual conventions for the EventBuffer data type
--
-- There could be up to 1000 event log entries
-- maintained by the system in FIFO order.
--
EventBuffer ::= INTEGER (1..1000)
-- Textual conventions for the UserBuffer data type
--
-- There could be up to 100 user action log entries
-- maintained by the system in FIFO order.
--
UserBuffer ::= INTEGER (1..100)
-- Textual conventions for the LogonID data type
--
-- Logon ID is in printable ASCII character set, and up to 15
-- chars.
-- A NULL value indicates no valid Logon ID is specified.
--
LogonID ::= DisplayString (SIZE (0..15))
-- Textual conventions for the HashedPasswd data type
--
-- Passwords maintained by the embedded LuxN application are
-- hashed (one-way encrypted) to protect them from
-- unauthorized view. A simple hashing (message digest)
-- algorithm like the one below can be used to hide the
-- passwords. LuxN passwords are only used to compare
-- against, so it's OK to hash them.
--
-- Let N be the length of the clear text password, up to 10
-- bytes. Let M be Twice maximum password length. Exactly
-- 20 bytes. Let R be the number of rounds of hashing. Say
-- 10. Let the password be stored in an array P with
-- dimension M. Note, array P is indexed from 1 and not
-- from 0 in the discussion below.
--
-- The following algorithm (due to Rasta Mansour) hashes
-- the array P in a one-way manner with a very low
-- probability of collision.
--
-- Fill the array P with the Password of Length N up
-- to the value of M. Simple cyclic copy of the clear
-- text password will do.
--
-- Execute the following rounds of the alogrithm below
-- on the array P.
--
-- For i=1 to R do
-- For j=1 to M do
-- Let k = ((j + i) mod M) + 1
-- Let P[j] = (P[j] + (k * P[k])) mod 256
-- if (P[j] == 0)
-- Let P[j] = k + N
--
-- Let k = ((k * N) mod M) + 1
-- Let c = P[j]
-- Let P[j] = P[k]
-- Let P[k] = c
--
HashedPasswd ::= OCTET STRING (SIZE (1..20))
EncryptedCommunity ::= DisplayString (SIZE (0..32))
-- Textual conventions for the FileName data type
--
-- file name may be any alpha-numeric character string up
-- to 32 characters.
--
FileName ::= DisplayString (SIZE (0..32))
-- Textual conventions for the EntityName data type
--
-- EntityName is in printable ASCII character set, and up
-- to 15 chars.
-- A NULL value indicates no valid name is specified.
--
EntityName ::= DisplayString (SIZE (0..15))
-- Textual conventions for the Date and Time data type
--
-- field Octets Contents Range
-- ----- ------ -------------------- --------
-- 1 1-2 year 0..65535
-- (in big endian order)
-- 2 3 month 1..12
-- 3 4 day 1..31
-- 4 5 hour 0..23
-- 5 6 minutes 0..59
-- 6 7 seconds 0..59
-- 7 8 deci-seconds 0..9
-- (100 milliseconds)
-- 8 9 direction from UTC "+" | "-"
-- 9 10 hours from UTC 0..11
-- 10 11 minutes from UTC 0..59
--
-- Note, if only local time is known, then timezone information
-- (fields 8-10) is not present.
--
-- If only date is known, then the time part (fields 5-11) is not
-- present.
--
DateAndTime ::= DisplayString (SIZE( 0..20 ))
-- Textual conventions for the VersionString data type
--
-- A version string is in the form:
--
-- 'V' major_num '.' minor_num '.' alpha_num
--
-- Where, major_num and minor_num can be any 3 digit number. The
-- alpha_num is any lower case alpha character. An example of a
-- version string in this syntax is: V1.05.c.
--
-- The rules for assignment (creation) of a version string are as
-- follows:
--
-- 1. If the interface or the functionality has significantly changed,
-- the major_num is incremented.
-- 2. If bugs are fixed but the functionality and the interface are
-- generally the same, the minor_num is incremented.
-- 3. For interium releases, specially during in-house testing, or
-- as experimental engineering bug fix release to a client, the
-- alpha_num is incremented.
--
VersionString ::= DisplayString (SIZE (0..12))
-- Textual conventions for the SerialString data type
--
-- Serial number may be any alpha numeric printable character string
-- up to 17 characters.
--
SerialString ::= DisplayString (SIZE (0..17))
-- Textual conventions for the SfpSerialString data type
--
-- SFP Serial number may be any alpha numeric printable character string
-- up to 24 characters.
--
SfpSerialString ::= DisplayString (SIZE (0..24))
-- Textual conventions for the ModelString data type
--
-- Model Type may be any alpha numeric printable character string
-- up to 10 characters.
--
ModelString ::= DisplayString (SIZE (0..10))
-- Textual conventions for the ModelNum data type
--
-- Model number may be any alpha numeric printable character string
-- up to 15 characters.
--
ModelNum ::= DisplayString (SIZE (0..15))
-- For SW download support
-- Textual conventions for the FtpMode data type
FtpMode ::= INTEGER { active(1), passive(2) }
-- Textual conventions for the DownloadType data type
DownloadType ::= DisplayString (SIZE (0..32))
-- Textual conventions for the DownloadLocation data type
DownloadLocation ::= INTEGER { local(1), remote(2), remote2(3) }
-- Textual conventions for the DownloadShelf data type
DownloadShelf ::= INTEGER (0..2)
-- Textual conventions for the DownloadSlot data type
DownloadSlot ::= INTEGER (0..17)
-- Textual conventions for the OSMode data type
OSMode ::= DisplayString (SIZE (0..10))
-- Textual conventions for the ReleaseDate data type
ReleaseDate ::= DisplayString (SIZE (0..10))
-- Textual conventions for the OSMode data type
OSState ::= INTEGER { operating(1), backup(2) }
-- Textual conventions for the UpdateOSMode data type
UpdateOSMode ::= INTEGER { toggle(1), revert(2) }
-- Textual conventions for the DownloadStatus data type
DownloadStatus ::= INTEGER { idle(1), ftp-inprogress(2), mod-inprogress(3) }
-- Textual conventions for the RingID name data type
RingIdName ::= DisplayString (SIZE (0..16))
-- Textual conventions for the PathID name data type
PathIdName ::= DisplayString (SIZE (0..16))
-- Textual conventions for the Timezone data type
Timezone ::= INTEGER
{
idlw(1),
nt(2),
ahst(3),
cat(4),
hst(5),
hdt(6),
yst(7),
ydt(8),
pst(9),
pdt(10),
mst(11),
mdt(12),
cst(13),
cdt(14),
est(15),
edt(16),
ast(17),
adt(18),
at(19),
wat(20),
gmt(21),
ut(22),
utc(23),
wet(24),
bst(25),
cet(26),
fwt(27),
met(28),
mewt(29),
swt(30),
mest(31),
mesz(32),
sst(33),
fst(34),
eet(35),
bt(36),
zp4(37),
zp5(38),
zp6(39),
zp7(40),
wast(41),
cct(42),
wadt(43),
jst(44),
act(45),
east(46),
gst(47),
eadt(48),
idle(49),
nzst(50),
nzt(51),
nzdt(52)
}
-- Textual conventions for the AlarmType data type
AlarmType ::= INTEGER
{
aircompr(1),
aircond(2),
airdryr(3),
batdschrg(4),
battery(5),
power(6),
clfan(7),
engine(8),
engoprg(9),
explgs(10),
fire(11),
firdetr(12),
flood(13),
fuse(14),
gen(15),
hiair(16),
hihum(17),
hitemp(18),
hiwtr(19),
intruder(20),
lwhum(21),
lwbatvg(22),
lwpres(23),
lwfuel(24),
lwtemp(25),
lwwtr(26),
cpmajor(27),
cpminor(28),
opendr(29),
pump(30),
rect(31),
recthi(32),
rectlo(33),
smoke(34),
toxicgas(35),
ventn(36),
na(37)
}
-- Textual conventions for the ZmsAdminString data type
ZmsAdminString ::= DisplayString (SIZE (0..32))
-- Textual conventions for the ZmsFileName data type
ZmsFileName ::= DisplayString (SIZE (0..64))
-- The elements in the manufacturing subgroup of the configuration group
mfgName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturing name of the device. Up to 30 characters"
::= { manufacturing 1 }
mfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the chassis"
::= { manufacturing 2 }
mfgSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the Chassis."
::= { manufacturing 3 }
mfgModelType OBJECT-TYPE
SYNTAX ModelString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Model type of the chassis. Up to 10 characters"
::= { manufacturing 4 }
mfgDefaultID OBJECT-TYPE
SYNTAX LogonID
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default one-time user ID. This ID should be used
for the first time access to the system. This ID
will not be accepted once a real user ID is added."
::= { manufacturing 5 }
mfgDfltPasswd OBJECT-TYPE
SYNTAX HashedPasswd
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Default one-time password to go with the default
user ID. The password may contain non-printable
characters up to 10 ASCII characters. Passwords
are hashed and are for comparison only"
::= { manufacturing 6 }
mfgNumShelves OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of shelves in the chassis. This number
reflects the number of rows of the table below.
This number is automatically adjusted everytime
a row is added to the table below."
::= { manufacturing 9 }
mfgShelfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MfgShelfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of shelves and the
number of slots per shelf in the chassis."
::= { manufacturing 10 }
mfgShelfEntry OBJECT-TYPE
SYNTAX MfgShelfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mfgShelfID }
::= { mfgShelfTable 1 }
MfgShelfEntry ::=
SEQUENCE
{
mfgShelfID CardShelf,
mfgNumSlots INTEGER
}
mfgShelfID OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Integer ID of each shelf in the chassis. The shelf number
is always one for both GM1608 and GM3217. In the case of
of GM3234, the bottom shelf is 1 while the top shelf is 2.
As for GMX128, the order of numbering is from the top shelf
to the bottom shelf. In other words, the top shelf is
assigned 1."
::= { mfgShelfEntry 1 }
mfgNumSlots OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total number of slots in a given shelf."
::= { mfgShelfEntry 2 }
mfgCRCChecksum OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"32 bit CRC of the manufacturing section. This CRC
is automatically calculated everytime information
is updated from the manufacturing section. The
manufacturing section is static once the chassis
leaves the LuxN manufacturing premise."
::= { manufacturing 11 }
mfgChassisType OBJECT-TYPE
SYNTAX ChassisType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of chassis."
::= { manufacturing 12 }
mfgPsType OBJECT-TYPE
SYNTAX INTEGER
{
dcOny(1),
acOnly(2),
mixedDcAc(3),
unknown(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of power supplies."
::= { manufacturing 13 }
mfgCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number for the chassis."
::= { manufacturing 14 }
-- The elements in the cp subgroup of the configuration group
cpIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the Active Communication Processor"
::= { cp 1 }
cpNetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Net mask for the Active Communication Processor"
::= { cp 2 }
cpMIBVersion OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Version of the LuxN MIB implemented by this device.
This value may be reset everytime a new CP code
is downloaded."
::= { cp 3 }
cpBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the Boot PROM code"
::= { cp 4 }
cpROMSize OBJECT-TYPE
SYNTAX INTEGER (1..16384)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { cp 5 }
cpNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { cp 6 }
cpSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { cp 7 }
cpSubDivEntry OBJECT-TYPE
SYNTAX CpSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpSubDivIndex }
::= { cpSubDivTable 1 }
CpSubDivEntry ::=
SEQUENCE
{
cpSubDivIndex INTEGER,
cpSubDivDescr DisplayString,
cpSubDivSize INTEGER,
cpSubDivOffset OCTET STRING,
cpSubDivImgVersion DisplayString,
cpSubDivImgDBVersion DisplayString
}
cpSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { cpSubDivEntry 1 }
cpSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { cpSubDivEntry 2 }
cpSubDivSize OBJECT-TYPE
SYNTAX INTEGER (1..3145728)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in bytes"
::= { cpSubDivEntry 3 }
cpSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { cpSubDivEntry 4 }
cpSubDivImgVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Version of each Images in ROM."
::= { cpSubDivEntry 5 }
cpSubDivImgDBVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Database Version of each Images in ROM."
::= { cpSubDivEntry 6 }
cpTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
active or standby communication processor"
::= { cp 8 }
cpEntry OBJECT-TYPE
SYNTAX CpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpCardShelf, cpCardSlot }
::= { cpTable 1 }
CpEntry ::=
SEQUENCE
{
cpCardShelf CardShelf,
cpCardSlot INTEGER,
cpMode RedundancyMode,
cpDsgntdMode RedundancyMode,
cpState CardState,
cpMacAddr OCTET STRING,
cpName CardName,
cpMfgDate DateAndTime,
cpSerialNum SerialString,
cpModelType INTEGER,
cpFWVersionID VersionString,
cpSetState INTEGER,
cpHWName DisplayString,
cpCleiNum DisplayString,
cpModelNum DisplayString
}
cpCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { cpEntry 1 }
cpCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { cpEntry 2 }
cpMode OBJECT-TYPE
SYNTAX RedundancyMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the communication processor. The valid types
are Active or Standby."
::= { cpEntry 3 }
cpDsgntdMode OBJECT-TYPE
SYNTAX RedundancyMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Designation Type of the communication processor. The
valid types are Active or Standby."
::= { cpEntry 4 }
cpState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the CP card."
::= { cpEntry 5 }
cpMacAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MAC address of the Communication processor in HEX"
::= { cpEntry 6 }
cpName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Display (Network) name of the Communication processor"
::= { cpEntry 7 }
cpMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the CP card"
::= { cpEntry 8 }
cpSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the CP card."
::= { cpEntry 9 }
cpModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the CP."
::= { cpEntry 10 }
cpFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the CP FW code"
::= { cpEntry 11 }
cpSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the CP to do a warmboot. A get on this will
always return an other."
::= { cpEntry 12 }
cpHWName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Hardware name of the CP Card."
::= { cpEntry 13 }
cpCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the mux/dmux Card."
::= { cpEntry 14 }
cpModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model number of the CP card. Up to 15 characters"
::= { cpEntry 15 }
cpSetMode OBJECT-TYPE
SYNTAX RedundancyMode
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Toggle the Active/Standby mode of the active CP."
::= { cp 9 }
cpSNMPTrapHost1 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the first SNMP Trap host. A NULL IP
address means no TRAP should be sent to this address.
Duplicate IP addresses will be rejected."
::= { cp 10 }
cpSNMPTrapHost2 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the second SNMP Trap host. A NULL IP
address means no TRAP should be sent to this address.
Duplicate IP addresses will be rejected."
::= { cp 11 }
cpSNMPTrapHost3 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the third SNMP Trap host. A NULL IP
address means no TRAP should be sent to this address.
Duplicate IP addresses will be rejected."
::= { cp 12 }
cpSNMPSendTrap OBJECT-TYPE
SYNTAX Boolean
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If set to true, traps will be sent out. If set to
false, traps will not be sent out. This variable
is reset to true (enable) on each boot cycle."
::= { cp 13 }
cpGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gateway IP Address of the Active Communication Processor. A
NULL IP address means Gateway hasn't been configured."
::= { cp 14 }
cpMaxSessions OBJECT-TYPE
SYNTAX INTEGER (1..6)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum allowed Telnet Sessions on the Active Communication
Processor. Valid values are 1 to 6."
::= { cp 15 }
cpSessionTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum timeout (in seconds) that can be set for a
Telnet session on the Active Communication Processor.
Valid values are greater than 30 secs."
::= { cp 16 }
cpDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current Date on the Active Communication Processor.
The format is in the form of mm-dd-yy in which mm
is the two digit month, dd is the two digit day of
the month, and yy is the two digit year."
::= { cp 17 }
cpTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Current Time on the Active Communication Processor.
The format is in the form of hh:mm:ss in which
hh is the hour, mm is the minute and ss is the
second. The valid values for hour goes from 0
to 23. In order to work with LuxN NMS, it needs to be
set to GMT time"
::= { cp 18 }
cpGetCommunity OBJECT-TYPE
SYNTAX EncryptedCommunity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable SNMP Get Community String."
::= { cp 19 }
cpSetCommunity OBJECT-TYPE
SYNTAX EncryptedCommunity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User Configurable SNMP Set Community String."
::= { cp 20 }
cpSystemName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..59))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User Configurable System Name."
::= { cp 21 }
cpSNMPTrapCommunity1 OBJECT-TYPE
SYNTAX EncryptedCommunity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap community string for first trap host.
Will return an error if the corresponding trap host is
invalid or not set."
::= { cp 22 }
cpSNMPTrapCommunity2 OBJECT-TYPE
SYNTAX EncryptedCommunity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap community string for second trap host.
Will return an error if the corresponding trap host is
invalid or not set."
::= { cp 23 }
cpSNMPTrapCommunity3 OBJECT-TYPE
SYNTAX EncryptedCommunity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap community string for third trap host.
Will return an error if the corresponding trap host is
invalid or not set."
::= { cp 24 }
cpHttp OBJECT-TYPE
SYNTAX INTEGER {enabled(1), disabled(2)}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"HTTP server enabled or not."
::= { cp 25 }
cpIMNIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IMN Ip address. Use for IP/IWM"
::= { cp 26 }
cpUpsrMode OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UPSR mode: enable and disable."
::= { cp 27 }
cpAutoModuleUpdate OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to automatically enable/disable module update."
::= { cp 28 }
cpSNMPTrapHost4 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the fourth SNMP Trap host. A NULL IP
address means no TRAP should be sent to this address.
Duplicate IP addresses will be rejected."
::= { cp 29 }
cpSNMPTrapHost5 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the fifth SNMP Trap host. A NULL IP
address means no TRAP should be sent to this address.
Duplicate IP addresses will be rejected."
::= { cp 30 }
cpSNMPTrapCommunity4 OBJECT-TYPE
SYNTAX EncryptedCommunity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap community string for fourth trap host.
Will return an error if the corresponding trap host is
invalid or not set."
::= { cp 31 }
cpSNMPTrapCommunity5 OBJECT-TYPE
SYNTAX EncryptedCommunity
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap community string for fifth trap host.
Will return an error if the corresponding trap host is
invalid or not set."
::= { cp 32 }
cpSNMPTrapHostPort1 OBJECT-TYPE
SYNTAX INTEGER(0..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap port for the first trap host.
Default value is 162"
::= { cp 33 }
cpSNMPTrapHostPort2 OBJECT-TYPE
SYNTAX INTEGER(0..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap port for the second trap host.
Default value is 162"
::= { cp 34 }
cpSNMPTrapHostPort3 OBJECT-TYPE
SYNTAX INTEGER(0..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap port for the third trap host.
Default value is 162"
::= { cp 35 }
cpSNMPTrapHostPort4 OBJECT-TYPE
SYNTAX INTEGER(0..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap port for the fourth trap host.
Default value is 162"
::= { cp 36 }
cpSNMPTrapHostPort5 OBJECT-TYPE
SYNTAX INTEGER(0..65534)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable trap port for the fifth trap host.
Default value is 162"
::= { cp 37 }
cpRedunSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpRedunSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory
of redundant (standby) MPM"
::= { cp 38 }
cpRedunSubDivEntry OBJECT-TYPE
SYNTAX CpRedunSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpRedunSubDivIndex }
::= { cpRedunSubDivTable 1 }
CpRedunSubDivEntry ::=
SEQUENCE
{
cpRedunSubDivIndex INTEGER,
cpRedunSubDivDescr DisplayString,
cpRedunSubDivImgVersion DisplayString,
cpRedunSubDivImgDBVersion DisplayString
}
cpRedunSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { cpRedunSubDivEntry 1 }
cpRedunSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { cpRedunSubDivEntry 2 }
cpRedunSubDivImgVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Version of each Images in ROM."
::= { cpRedunSubDivEntry 3 }
cpRedunSubDivImgDBVersion OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Database Version of each Images in ROM."
::= { cpRedunSubDivEntry 4 }
cpTimezone OBJECT-TYPE
SYNTAX Timezone
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the internation time zone used by the
MPM to determine system time. The time zone is
only used to system time calculations when NTP
is enabled"
::= { cp 39 }
cpNtpState OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether NTP support is enabled or
disabled."
::= { cp 40 }
cpNtpTimeserver OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the NTP time server queries for updates."
::= { cp 41 }
cpNtpUpdateInterval OBJECT-TYPE
SYNTAX INTEGER (5..1440)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the NTP time update interval in minutes."
::= { cp 42 }
cpTelnetClient OBJECT-TYPE
SYNTAX INTEGER
{
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable telnet client for active telnet sessions."
::= { cp 43 }
cpLogMask OBJECT-TYPE
SYNTAX INTEGER
{
disabled(1),
emerg(2),
alert(3),
crit(4),
err(5),
warn(6),
notice(7),
info(8),
debug(9)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the log mask. The masks are equivalent to
syslog priorities."
::= { cp 44 }
cpLogServer1 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the first log server. A NULL IP
address will remove this entry. Duplicate IP
addresses will be rejected."
::= { cp 45 }
cpLogServer2 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the first log server. A NULL IP
address will remove this entry. Duplicate IP
addresses will be rejected."
::= { cp 46 }
cpLogServer3 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the first log server. A NULL IP
address will remove this entry. Duplicate IP
addresses will be rejected."
::= { cp 47 }
cpLogServer4 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the first log server. A NULL IP
address will remove this entry. Duplicate IP
addresses will be rejected."
::= { cp 48 }
cpLogServer5 OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP Address of the first log server. A NULL IP
address will remove this entry. Duplicate IP
addresses will be rejected."
::= { cp 49 }
-- The elements in the cc subgroup of the configuration group
ccBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the CC Boot PROM code"
::= { cc 1 }
ccROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the CC ROM in Kilobyes"
::= { cc 2 }
ccNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { cc 3 }
ccSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { cc 4 }
ccSubDivEntry OBJECT-TYPE
SYNTAX CcSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccSubDivIndex }
::= { ccSubDivTable 1 }
CcSubDivEntry ::=
SEQUENCE
{
ccSubDivIndex INTEGER,
ccSubDivDescr DisplayString,
ccSubDivSize INTEGER,
ccSubDivOffset OCTET STRING
}
ccSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { ccSubDivEntry 1 }
ccSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { ccSubDivEntry 2 }
ccSubDivSize OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { ccSubDivEntry 3 }
ccSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { ccSubDivEntry 4 }
ccNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of CC rows in the following table. This number
is automatically updated whenever a new row is added
to the table below."
::= { cc 5 }
ccTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
channel card"
::= { cc 6 }
ccEntry OBJECT-TYPE
SYNTAX CcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccCardLocation, ccCardShelf, ccCardSlot }
::= { ccTable 1 }
CcEntry ::=
SEQUENCE
{
ccCardLocation CardLocation,
ccCardShelf CardShelf,
ccCardSlot INTEGER,
ccMfgDate DateAndTime,
ccSerialNum SerialString,
ccModelType INTEGER,
ccName CardName,
ccFWVersionID VersionString,
ccMfgBiasCurrent INTEGER,
ccMfgModulation INTEGER,
ccMfgApc INTEGER,
ccMfgIwmModulation INTEGER,
ccMfgRefClock INTEGER,
ccMfgClockDiv INTEGER,
ccBandwidth INTEGER,
ccSetState INTEGER,
connMuxChassis INTEGER,
connMuxShelf INTEGER,
connMuxSlot INTEGER,
connMuxPort INTEGER,
connDemuxChassis INTEGER,
connDemuxShelf INTEGER,
connDemuxSlot INTEGER,
connDemuxPort INTEGER,
ccModelNum DisplayString,
ccLinkITUNum DisplayString,
ccLinkWavelength DisplayString,
ccLaserType INTEGER,
ccRecvDiode INTEGER,
ccLinkAutoDisable INTEGER,
ccLinkName LinkName,
ccCsimModule INTEGER,
ccHWName CardName,
ccBackpackModule INTEGER,
ccBackpackRxITUNumber DisplayString,
ccBackpackTxITUNumber DisplayString,
ccBackpackRxInsertionLoss DisplayString,
ccBackpackTxInsertionLoss DisplayString,
ccBackpackRxExpressLoss DisplayString,
ccBackpackTxExpressLoss DisplayString,
ccSwitchByShelfSlot DisplayString,
ccPathID PathIdName,
ccCpeDisableThreshold INTEGER,
ccCpeReEnableThreshold INTEGER,
connTxNonMuxDmuxCardType INTEGER,
connTxNonMuxDmuxPort INTEGER,
connTxNonMuxDmuxShelf INTEGER,
connTxNonMuxDmuxSlot INTEGER,
connRxNonMuxDmuxCardType INTEGER,
connRxNonMuxDmuxPort INTEGER,
connRxNonMuxDmuxShelf INTEGER,
connRxNonMuxDmuxSlot INTEGER,
ccUpsrMode INTEGER,
ccPairShelf INTEGER,
ccPairSlot INTEGER,
ccAdminState INTEGER,
ccRegenPairShelf INTEGER,
ccRegenPairSlot INTEGER,
ccCleiNum DisplayString,
connCpeTxMcmescShelf INTEGER,
connCpeTxMcmescSlot INTEGER,
connCpeTxMcmescPort INTEGER,
connCpeRxMcmescShelf INTEGER,
connCpeRxMcmescSlot INTEGER,
connCpeRxMcmescPort INTEGER,
ccNumPorts INTEGER
}
ccCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the card. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { ccEntry 1 }
ccCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2"
::= { ccEntry 2 }
ccCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { ccEntry 3 }
ccMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of calibration of the CC card"
::= { ccEntry 4 }
ccSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the CC card."
::= { ccEntry 5 }
ccModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the channel card."
::= { ccEntry 6 }
ccName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the channel card"
::= { ccEntry 7 }
ccFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the CC FW code"
::= { ccEntry 8 }
ccMfgBiasCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bias current for the optical laser. This is the
preset manufacturing value"
::= { ccEntry 9 }
ccMfgModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency modulation for the optical laser. This
value is the preset manufacturing value."
::= { ccEntry 10 }
ccMfgApc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The APC value. This value is the preset
manufacturing value"
::= { ccEntry 11 }
ccMfgIwmModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency modulation for the IWM channel. This
value is the preset manufacturing value"
::= { ccEntry 12 }
ccMfgRefClock OBJECT-TYPE
SYNTAX INTEGER
{
en1660(1),
en1944(2),
en1953(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The value of the reference clock in decimal notation.
For a given value, like 1660-EN, the actual value is
16.60-EN. In otherwords, assume a two digit decimal
point, plus any appropriate scaling factor. This
value is the preset manufacturing value."
::= { ccEntry 13 }
ccMfgClockDiv OBJECT-TYPE
SYNTAX INTEGER { dout-1250(1), dout-622(2), dout-155(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The clock divisor. Values are 1250, 622 or 155 in the
appropriate clock frequency scale."
::= { ccEntry 14 }
ccBandwidth OBJECT-TYPE
SYNTAX INTEGER
{
oc3(1),
oc12(2),
oc48(3),
gbEthernet(4),
fibreChannel(5),
oc192(6),
gbE10(9),
fibreChannelX2(10)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The bandwidth of the channel card. "
::= { ccEntry 15 }
ccSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2),
enableLoopback(3),
disableLoopback(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the CC to do a warmboot or loopback. A get
on this will always return an other."
::= { ccEntry 16 }
connMuxChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The connected mux chassis."
::= { ccEntry 17 }
connMuxShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected mux shelf."
::= { ccEntry 18 }
connMuxSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected mux slot."
::= { ccEntry 19 }
connMuxPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected mux port. "
::= { ccEntry 20 }
connDemuxChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The connected demux chassis."
::= { ccEntry 21 }
connDemuxShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected demux shelf."
::= { ccEntry 22 }
connDemuxSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected demux slot."
::= { ccEntry 23 }
connDemuxPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected demux port. "
::= { ccEntry 24 }
ccModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model number of the CC card. Up to 15 characters"
::= { ccEntry 25 }
ccLinkITUNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link ITU number of the CC card. Up to 15 characters"
::= { ccEntry 26 }
ccLinkWavelength OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link Wavelength of the CC card"
::= { ccEntry 27 }
ccLaserType OBJECT-TYPE
SYNTAX INTEGER { uncooled(1), cooled(2)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Laser Type of the Channel Card."
::= { ccEntry 28 }
ccRecvDiode OBJECT-TYPE
SYNTAX INTEGER { apd(1), pin(2)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive Diode of the Channel Card."
::= { ccEntry 29 }
ccLinkAutoDisable OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2), enableCpeRxPassThru(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable the CPE link when the
threshold value crosses the lower hysteresis
limit. The default value is disable. CPE disable
with CPE Rx pass through is identical to normal
CPE disable with the added feature that the remote
CPE Tx will be disabled if a loss of light condition
is detected on the local CPE Rx."
::= { ccEntry 30 }
ccLinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link name for fiber between the local and the
remote cc card."
::= { ccEntry 31 }
ccCsimModule OBJECT-TYPE
SYNTAX INTEGER { installed(1), notinstalled(2), preconfigured(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Whether colorSIM module is physically present,
not installed or preconfigured."
::= { ccEntry 32 }
ccHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Hardware name of the CC Card."
::= { ccEntry 33 }
ccBackpackModule OBJECT-TYPE
SYNTAX INTEGER { installed(1), notInstalled(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Presence of Backpack module, installed or not Installed."
::= { ccEntry 34 }
ccBackpackRxITUNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rx ITU number of backpack."
::= { ccEntry 35 }
ccBackpackTxITUNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tx ITU number of backpack."
::= { ccEntry 36 }
ccBackpackRxInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rx Insertion loss of backpack."
::= { ccEntry 37 }
ccBackpackTxInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tx Insertion loss of backpack."
::= { ccEntry 38 }
ccBackpackRxExpressLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Rx Express loss of backpack."
::= { ccEntry 39 }
ccBackpackTxExpressLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tx Express loss of backpack."
::= { ccEntry 40 }
ccSwitchByShelfSlot OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Initiate manual UPSR switching by shelf and slot."
::= { ccEntry 41 }
ccPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { ccEntry 42 }
ccCpeDisableThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CPE Disable Threshold (Link Rx Power) in dBm. The limit
is from -32 to -8, but input should be an absolute value
if using mib browser. A value of 0 in this field indicates
that UPSR is not supported. This value will not take affect
until ccLinkAutoDisable has been enabled."
::= { ccEntry 43 }
ccCpeReEnableThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CPE Re-enable threshold (Link Rx Power) in dBm. The limit
is from -31 to -7, but input should be an absolute value
if using mib browser. A value of 0 in this field indicates
that UPSR is not supported. This value will not take affect
until ccLinkAutoDisable has been enabled."
::= { ccEntry 44 }
connTxNonMuxDmuxCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of module connected to Tx port of OCM."
::= { ccEntry 45}
connTxNonMuxDmuxPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Conn port for CC's Tx port.Possible values based on
card types that can connect to OCM are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx."
::= { ccEntry 46}
connTxNonMuxDmuxShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card conn to Tx port of OCM. Valid values are: 1 to 10."
::= { ccEntry 47 }
connTxNonMuxDmuxSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to Tx port of OCM."
::= { ccEntry 48 }
connRxNonMuxDmuxCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of module connected to Rx port of OCM."
::= { ccEntry 49}
connRxNonMuxDmuxPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Conn port for CC's Rx port.Possible values based on
card types that can connect to OCM are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCMU/OCMITU/MCMT1/MCME1/OCM10G/OCM10G: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx."
::= { ccEntry 50}
connRxNonMuxDmuxShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card conn to Rx port of OCM. Valid values are: 1 to 10."
::= { ccEntry 51 }
connRxNonMuxDmuxSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to Rx port of OCM."
::= { ccEntry 52 }
ccUpsrMode OBJECT-TYPE
SYNTAX INTEGER { primary(1), backup(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"UPSR mode for CC card: primary or backup. If not in
upsr configuration, value is na. This value will not
take affect until ccLinkAutoDisable has been enabled."
::= { ccEntry 53}
ccPairShelf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shelf of other CC card in pair."
::= { ccEntry 54 }
ccPairSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot of other CC card in pair.
Input 0 to unpair OCMs and delete RSM connections if any."
::= { ccEntry 55 }
ccAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that cc card. Default value is enable.
When disabled, no alarms/events gets
generated. For remote CC, the default value is disabled"
::= { ccEntry 56}
ccRegenPairShelf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shelf of other CC card in OCM regeneration pair. This value
will not take affect until ccLinkAutoDisable has been enabled."
::= { ccEntry 57 }
ccRegenPairSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot of other CC card in OCM regeneration pair.
Input 0 to unpair OCMs involved. This value will not take affect
until ccLinkAutoDisable has been enabled."
::= { ccEntry 58 }
ccCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the CC Card."
::= { ccEntry 59 }
connCpeTxMcmescShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected MCMESC shelf."
::= { ccEntry 60 }
connCpeTxMcmescSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected MCMESC slot."
::= { ccEntry 61 }
connCpeTxMcmescPort OBJECT-TYPE
SYNTAX INTEGER{ linktx(1), linkrx(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected MCMESC port. 1=Link Tx, 2=Link Rx."
::= { ccEntry 62 }
connCpeRxMcmescShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected MCMESC shelf."
::= { ccEntry 63 }
connCpeRxMcmescSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected MCMESC slot."
::= { ccEntry 64 }
connCpeRxMcmescPort OBJECT-TYPE
SYNTAX INTEGER { linktx(1), linkrx(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected MCMESC port. 1=Link Tx, 2=Link Rx."
::= { ccEntry 65 }
ccNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each CC card."
::= { ccEntry 66 }
-- The elements in the mux subgroup of the configuration group
muxBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the Mux Boot PROM code"
::= { mux 1 }
muxROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { mux 2 }
muxNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { mux 3 }
muxSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { mux 4 }
muxSubDivEntry OBJECT-TYPE
SYNTAX MuxSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { muxSubDivIndex }
::= { muxSubDivTable 1 }
MuxSubDivEntry ::=
SEQUENCE
{
muxSubDivIndex INTEGER,
muxSubDivDescr DisplayString,
muxSubDivSize INTEGER,
muxSubDivOffset OCTET STRING
}
muxSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { muxSubDivEntry 1 }
muxSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { muxSubDivEntry 2 }
muxSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { muxSubDivEntry 3 }
muxSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { muxSubDivEntry 4 }
muxNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of MUX rows in the following table. This number
is automatically updated whenever a new row is added
to the table below."
::= { mux 5 }
muxTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
MUX card"
::= { mux 6 }
muxEntry OBJECT-TYPE
SYNTAX MuxEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { muxCardLocation, muxCardShelf, muxCardSlot }
::= { muxTable 1 }
MuxEntry ::=
SEQUENCE
{
muxCardLocation CardLocation,
muxCardShelf CardShelf,
muxCardSlot INTEGER,
muxModelNum DisplayString,
muxMfgDate DateAndTime,
muxSerialNum SerialString,
muxModelType INTEGER,
muxName CardName,
muxFWVersionID VersionString,
muxSetState RebootType,
muxNumPorts INTEGER,
muxUpgradeFlag INTEGER,
muxHWName CardName,
muxPathID PathIdName,
muxAdminState INTEGER,
muxCleiNum DisplayString,
muxChannelSpacing INTEGER,
muxStartItu INTEGER,
muxEndItu INTEGER,
muxChannelsPerBand INTEGER,
muxBands INTEGER
}
muxCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { muxEntry 1 }
muxCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { muxEntry 2 }
muxCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { muxEntry 3 }
muxModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model number for module."
::= { muxEntry 4 }
muxMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { muxEntry 5 }
muxSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the module."
::= { muxEntry 6 }
muxModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module"
::= { muxEntry 7 }
muxName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module"
::= { muxEntry 8 }
muxFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the FW code"
::= { muxEntry 9 }
muxSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the mux to do a warmboot. A get on this will
always return an other."
::= { muxEntry 10 }
muxNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each MUX card. Should be six"
::= { muxEntry 11 }
muxUpgradeFlag OBJECT-TYPE
SYNTAX INTEGER { upgradable(1), notUpgradable(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MUX card's status is upgradable or not."
::= { muxEntry 12 }
muxHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Hardware name of the mux/dmux Card."
::= { muxEntry 13 }
muxPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { muxEntry 14 }
muxAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that mux card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { muxEntry 15}
muxCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the mux/dmux Card."
::= { muxEntry 16 }
muxChannelSpacing OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ITU channel spacing for the mux/demux card. Only valid for MD100-40
and BD4 Modules."
::= { muxEntry 17 }
muxStartItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"First ITU channel supported by the module. Only valid for MD100-40
and BD4 Modules."
::= { muxEntry 18 }
muxEndItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last ITU channel supported by the module. Only valid for MD100-40
and BD4 Modules."
::= { muxEntry 19 }
muxChannelsPerBand OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of channels per optical band supported by the module.
Only valid for BD-4 and MD100-40 module."
::= { muxEntry 20 }
muxBands OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bands supported by the module. Only valid for
BD-4 and MD100-40 module."
::= { muxEntry 21 }
muxPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of MUX's port rows in the following table. This
number is automatically updated whenever a new row is
added to the table below.Basically a product of
# of mux cards and # of ports on each card. Hence it
would have a value of 6, 12, 18 etc.."
::= { mux 7 }
muxPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
MUX card's port."
::= { mux 8 }
muxPortEntry OBJECT-TYPE
SYNTAX MuxPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { muxPortCardLocation, muxPortCardShelf, muxPortCardSlot, muxPortIndex }
::= { muxPortTable 1 }
MuxPortEntry ::=
SEQUENCE
{
muxPortCardLocation CardLocation,
muxPortCardShelf CardShelf,
muxPortCardSlot SlotInput,
muxPortIndex INTEGER,
muxWavelength INTEGER,
muxInsertLoss DisplayString,
muxConnCardType INTEGER,
muxConnLocation CardLocation,
muxConnShelf ShelfInput,
muxConnSlot SlotInput,
muxConnPort INTEGER,
muxPortType INTEGER,
muxConnChassisID DisplayString,
muxConnSystemName DisplayString,
muxConnIpAddress IpAddress,
muxPortAvgInsertionLoss DisplayString,
muxPortMaxInsertionLoss DisplayString,
muxPortTapRatio DisplayString
}
muxPortCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the MUX's port. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { muxPortEntry 1 }
muxPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { muxPortEntry 2 }
muxPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { muxPortEntry 3 }
muxPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port's index. Ports 1 through 4 can be use
for connection with OCM family or MCMT1/MCME1 only."
::= { muxPortEntry 4 }
muxWavelength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port's wavelength: either ITU number or actual
wavelength in nm. Supported by all Mux modules
except MD100-40 & BD4."
::= { muxPortEntry 5 }
muxInsertLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Mux Port insertion Loss range. Supported by all Mux
modules except MD100-40 & BD4."
::= { muxPortEntry 6 }
muxConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Module type connected to mux port. Supported by all
Mux modules except MD100-40 & BD4."
::= { muxPortEntry 7 }
muxConnLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The chassis's location of the card conn to. Supported
by all Mux modules except MD100-40 & BD4."
::= { muxPortEntry 8 }
muxConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2.
Supported by all Mux modules except MD100-40 & BD4."
::= { muxPortEntry 9 }
muxConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to. To delete a
connection associated with a specified port, set this
variable to 0. Supported by all Mux modules except
MD100-40 & BD4."
::= { muxPortEntry 10 }
muxConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Conn port for MUX/DMUX's port. Possible values based on
card types that can be connected to are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx.
Entry supported by all Mux modules except MD100-40 & BD4."
::= { muxPortEntry 11 }
muxPortType OBJECT-TYPE
SYNTAX INTEGER { mux(1), demux(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the MUX's port. Supported by all Mux modules except
MD100-40 & BD4."
::= { muxPortEntry 12 }
muxConnChassisID OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Chassis ID of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the chassis Id of the local node. Supported by all Mux modules except
MD100-40 & BD4."
::= { muxPortEntry 13}
muxConnSystemName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Name of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the sysetem name of the local node. Supported by all Mux modules except
MD100-40 & BD4."
::= { muxPortEntry 14}
muxConnIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IpAddress of the connected node. User config. If local
connection, a set on it would return an error; would be automatically
be set to the IP address of the node. Supported by all Mux modules
except MD100-40 & BD4."
::= { muxPortEntry 15}
muxPortAvgInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average port insertion loss for the port category.
Valid only for MD100-40 & BD4 modules."
::= { muxPortEntry 16}
muxPortMaxInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum port insertion loss for the port category.
Valid only for MD100-40 & BD4 modules."
::= { muxPortEntry 17}
muxPortTapRatio OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Tap ratio for the port category.
Valid only for MD100-40 & BD4 modules."
::= { muxPortEntry 18}
-- The elements in the ps subgroup of the configuration group
psNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of PS (power supply) rows in the following table.
This number is automatically updated whenever a new row is added
to the table below."
::= { ps 1 }
psTable OBJECT-TYPE
SYNTAX SEQUENCE OF PsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
PS module."
::= { ps 2 }
psEntry OBJECT-TYPE
SYNTAX PsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { psID }
::= { psTable 1 }
PsEntry ::=
SEQUENCE
{
psID INTEGER,
psMode RedundancyMode,
psMfgDate DateAndTime,
psSerialNum SerialString,
psModelType ModelString
}
psID OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The module ID the ps module is in. Valid values are: 1 to 4"
::= { psEntry 1 }
psMode OBJECT-TYPE
SYNTAX RedundancyMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Mode of the PS module. Valid values are: active or
standby"
::= { psEntry 2 }
psMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the PS module."
::= { psEntry 3 }
psSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Serial # of the PS module. Not Supported Yet."
::= { psEntry 4 }
psModelType OBJECT-TYPE
SYNTAX ModelString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Model type of the PS module. Up to 10 characters.
Not Supported Yet."
::= { psEntry 5 }
-- The elements in the download subgroup of the configuration group
dlFtpTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlFtpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
FTP server"
::= { download 1 }
dlFtpEntry OBJECT-TYPE
SYNTAX DlFtpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dlFtpIp }
::= { dlFtpTable 1 }
DlFtpEntry ::=
SEQUENCE
{
dlFtpIp IpAddress,
dlFtpLogonID LogonID,
dlFtpPasswd DisplayString,
dlFtpMode FtpMode,
dlFtpPort INTEGER
}
dlFtpIp OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the FTP server."
::= { dlFtpEntry 1 }
dlFtpLogonID OBJECT-TYPE
SYNTAX LogonID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The FTP user ID for this FTP server. Up to 15 chars."
::= { dlFtpEntry 2 }
dlFtpPasswd OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Password for the above FTP Logon ID. This password
is NOT hashed. Proper security access is required
to set and view this element. Most FTP connections,
however, are using anonymous logon ID with no
special password requirements."
::= { dlFtpEntry 3 }
dlFtpMode OBJECT-TYPE
SYNTAX FtpMode
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP server modes. The choices are: active or passive,
active may be necessary for users behind a firewall."
::= { dlFtpEntry 4 }
dlFtpPort OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"FTP port. This port is used in conjunction with the
FTP IP address for establishing a connection to the FTP
server. Any valid IP port may be entered. Setting this
element to zero (0) will cause the standard FTP port (21)
to be used."
::= { dlFtpEntry 5 }
dlPreQualTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlPreQualEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
PreQual table."
::= { download 2 }
dlPreQualEntry OBJECT-TYPE
SYNTAX DlPreQualEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dlPreQualTypeVersion }
::= { dlPreQualTable 1 }
DlPreQualEntry ::=
SEQUENCE
{
dlPreQualTypeVersion DisplayString,
dlPreQualResult INTEGER
}
dlPreQualTypeVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..42))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Image type and version to be prequalified
before downloading. The string format is :
type,version. The prequal action will be
taken after setting version."
::= { dlPreQualEntry 1 }
dlPreQualResult OBJECT-TYPE
SYNTAX INTEGER { compatible(1), incompatible(2), unknown-version(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The result after comparing type and version of the
selected download image with the compatibility
matrix. The result is either compatible, incompatible
or unknown version. (Not available at this time).
The default is compatible."
::= { dlPreQualEntry 2 }
dlDownloadTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlDownloadEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for
download and activation."
::= { download 3 }
dlDownloadEntry OBJECT-TYPE
SYNTAX DlDownloadEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dlType, dlLocation, dlShelf, dlSlot }
::= { dlDownloadTable 1 }
DlDownloadEntry ::=
SEQUENCE
{
dlType DownloadType,
dlLocation DownloadLocation,
dlShelf DownloadShelf,
dlSlot DownloadSlot,
dlFilename DisplayString,
dlActivate INTEGER,
dlExportType INTEGER
}
dlType OBJECT-TYPE
SYNTAX DownloadType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Image type to be downloaded or to be activated. The
valid values are: all, mpms, boot, macf, mcme1,
mcmesc_code, mcmt1, mpm, ocm, ocm10g, oet, osam, osam_hp/lp,
rsm, upsm, uob.
When choosing all, all non-mpm images are downloaded, the
dlLocation should be set to local, dlShelf and dlSlot
should be set to 0, dlFilename should be set to the path
under which all the non-mpm images are put.
When choosing mpms, mpm's two associated images, boot and
mpm run code image, are downloaded, the dlLocation should
be set to local, dlShelf and dlSlot should be set to active
mpm's shelf and slot, dlFilename should be set to the path
under which the two images are put.
To MCME1/MCMT1 modules, mcm_fpag image will automatically
be downloaded when mcme1 or mcmt1 is selected."
::= { dlDownloadEntry 1 }
dlLocation OBJECT-TYPE
SYNTAX DownloadLocation
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The location to be downloaded or to be activated.
The choices are: local, remote or both. (Only local and
remote are supported at this time, LuxnOS has only local
choice and is not supported yet.
When dlType is set to all, only local is supported."
::= { dlDownloadEntry 2 }
dlShelf OBJECT-TYPE
SYNTAX DownloadShelf
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The destination shelf.
When dlType is set to all, dlShelf should be set to 0."
::= { dlDownloadEntry 3 }
dlSlot OBJECT-TYPE
SYNTAX DownloadSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the selected shelf.
When dlType is set to all, dlSlot should be set to 0."
::= { dlDownloadEntry 4 }
dlFilename OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The filename and path of the file to be downloaded -up to 255
characters.
When dlType is set to all, the dlFilename field should be set
to the path of the directory where the non-mpm images are stored.
When dlType is set to mpms, the dlFilename field should be set
to the path of the directory where the boot and mpm images are
stored.
The download action (imageupdate) will be taken after setting
the dlFilename field."
::= { dlDownloadEntry 5 }
dlActivate OBJECT-TYPE
SYNTAX INTEGER
{
no(1),
activateBackupFirmware(2),
activateBackupFPGA(3),
activateBackupFirmwareAndFPGA(4),
activateForAllLineCards(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Activate the backup image at the selected location.
To MCMESC, no, activateBackupFirmware, activateBackupFPGA
and activateBackupFirmwareAndFPGA are applicable.
To MCMT1/MCME1, no and activateBackupFirmwareAndFPGA are
applicable.
To other modules, no and activateBackupFirmware are
applicable.
When choosing activateForAllLineCards, the dlShelf and dlSlot
sholud be set to 0."
::= { dlDownloadEntry 6 }
dlExportType OBJECT-TYPE
SYNTAX INTEGER
{
import(1),
export(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The image indicated by dlType is to be exported
to the dlFilename using FTP. Ths element is
reset to none(1) after each export."
::= { dlDownloadEntry 7 }
dlOSTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlOSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for
LuxnOS table."
::= { download 4 }
dlOSEntry OBJECT-TYPE
SYNTAX DlOSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dlOSIndex }
::= { dlOSTable 1 }
DlOSEntry ::=
SEQUENCE
{
dlOSIndex INTEGER,
dlOSVersion VersionString,
dlOSState OSState,
dlOSRelDate ReleaseDate
}
dlOSIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Integer ID for each LuxnOS."
::= { dlOSEntry 1 }
dlOSVersion OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display the LuxnOS version."
::= { dlOSEntry 2 }
dlOSState OBJECT-TYPE
SYNTAX OSState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display the LuxnOS state: operating(1) is the current
operating LuxnOS, backup(2)is the backup LuxnOS."
::= { dlOSEntry 3 }
dlOSRelDate OBJECT-TYPE
SYNTAX ReleaseDate
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display the release date of the LuxnOS."
::= { dlOSEntry 4 }
dlUpdateOS OBJECT-TYPE
SYNTAX UpdateOSMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display and select Update LuxnOS Mode: toggle(1) to
toggle between operating and backup LuxnOS, revert(2)
to copy LuxnOS from the backup to the operating area.
The action will be taken after setting UpdateOS ."
::= { download 5 }
-- The elements in the FADM subgroup of the configuration group
fadmBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the OADM Boot PROM code"
::= { fadm 1 }
fadmROMSize OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { fadm 2 }
fadmNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { fadm 3 }
fadmSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF FadmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { fadm 4 }
fadmSubDivEntry OBJECT-TYPE
SYNTAX FadmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fadmSubDivIndex }
::= { fadmSubDivTable 1 }
FadmSubDivEntry ::=
SEQUENCE
{
fadmSubDivIndex INTEGER,
fadmSubDivDescr DisplayString,
fadmSubDivSize INTEGER,
fadmSubDivOffset OCTET STRING
}
fadmSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (1..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { fadmSubDivEntry 1 }
fadmSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { fadmSubDivEntry 2 }
fadmSubDivSize OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { fadmSubDivEntry 3 }
fadmSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { fadmSubDivEntry 4 }
fadmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of FADM rows in the following table. This number
is automatically updated whenever a new row is added
to the table below."
::= { fadm 5 }
fadmTable OBJECT-TYPE
SYNTAX SEQUENCE OF FadmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
OADM module"
::= { fadm 6 }
fadmEntry OBJECT-TYPE
SYNTAX FadmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fadmCardLocation, fadmCardShelf, fadmCardSlot }
::= { fadmTable 1 }
FadmEntry ::=
SEQUENCE
{
fadmCardLocation CardLocation,
fadmCardShelf CardShelf,
fadmCardSlot INTEGER,
fadmMfgDate DateAndTime,
fadmSerialNum SerialString,
fadmModelType INTEGER,
fadmName CardName,
fadmFWVersionID VersionString,
fadmSetState RebootType,
fadmNumPorts INTEGER,
fadmUpgradeFlag INTEGER,
fadmModelNum DisplayString,
fadmITUNumber1 INTEGER,
fadmITUNumber2 INTEGER,
fadmInsertionLoss1 DisplayString,
fadmInsertionLoss2 DisplayString,
fadmExpressLoss DisplayString,
fadmHWName CardName,
fadmPathID PathIdName,
fadmAdminState INTEGER,
fadmCleiNum DisplayString,
fadmBand DisplayString,
fadmChannelsPerBand INTEGER,
fadmStartItu INTEGER,
fadmEndItu INTEGER
}
fadmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the FADM Module."
::= { fadmEntry 1 }
fadmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the Module is in. Valid values
are: 1, 2 or 3 depending on the chassis type."
::= { fadmEntry 2 }
fadmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 21 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { fadmEntry 3 }
fadmMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the FADM card"
::= { fadmEntry 4 }
fadmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the FADM card."
::= { fadmEntry 5 }
fadmModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the FADM"
::= { fadmEntry 6 }
fadmName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Display (Network) name of the FADM Card"
::= { fadmEntry 7 }
fadmFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the FADM FW code"
::= { fadmEntry 8 }
fadmSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the fadm to do a warmboot. A get on this will
always return an other."
::= { fadmEntry 9 }
fadmNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers of FADM module."
::= { fadmEntry 10 }
fadmUpgradeFlag OBJECT-TYPE
SYNTAX INTEGER { upgradeable(1), notUpgradeable(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The FADM module's status is upgradeable or not."
::= { fadmEntry 11 }
fadmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model # of the FADM card. Up to 15 characters"
::= { fadmEntry 12 }
fadmITUNumber1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1's ITU wavelength."
::= { fadmEntry 13 }
fadmITUNumber2 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { fadmEntry 14 }
fadmInsertionLoss1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port 1's insertion loss in dB."
::= { fadmEntry 15 }
fadmInsertionLoss2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
""
::= { fadmEntry 16 }
fadmExpressLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Internal express port's insertion loss in dB."
::= { fadmEntry 17 }
fadmHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Hardware name of the FADM Card."
::= { fadmEntry 18 }
fadmPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { fadmEntry 19 }
fadmAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that fadm card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { fadmEntry 20}
fadmCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the fadm Card."
::= { fadmEntry 21 }
fadmBand OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical band supported by the module. Valid only for
BP-5 and BP-10 modules."
::= { fadmEntry 22 }
fadmChannelsPerBand OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of channels per optical band supported by the module.
Only valid for BP-5 and BP-10module."
::= { fadmEntry 23 }
fadmStartItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"First ITU channel supported by the module. Valid only for
BP-5 and BP-10 modules."
::= { fadmEntry 24 }
fadmEndItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last ITU channel supported by the module. Valid only for
BP-5 and BP-10 modules."
::= { fadmEntry 25 }
fadmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF FadmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the physical connection for each
FADM card's port."
::= { fadm 7 }
fadmPortEntry OBJECT-TYPE
SYNTAX FadmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fadmPortCardShelf, fadmPortCardSlot, fadmPortType }
::= { fadmPortTable 1 }
FadmPortEntry ::=
SEQUENCE
{
fadmPortCardShelf CardShelf,
fadmPortCardSlot SlotInput,
fadmPortType INTEGER,
fadmConnLocation CardLocation,
fadmConnIpAddress IpAddress,
fadmConnChassisID NodeName,
fadmConnSystemName NodeName,
fadmConnCardType INTEGER,
fadmConnPort INTEGER,
fadmConnShelf ShelfInput,
fadmConnSlot SlotInput
}
fadmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { fadmPortEntry 1 }
fadmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { fadmPortEntry 2 }
fadmPortType OBJECT-TYPE
SYNTAX INTEGER
{
connATx-AToD(1),
connARx-EXP(2),
localTx-Local(3),
localRx-Rx(4),
connBTx(5),
connBRx(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the FADM port. The order is CLI compatible.
For FADM model type, the ports are listed on the left column"
::= { fadmPortEntry 3 }
fadmConnLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The chassis's location of the card conn to."
::= { fadmPortEntry 4 }
fadmConnIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IpAddress of the connected node. User config. If local
connection, a set on it would return an error; would be automatically
be set to the IP address of the node "
::= { fadmPortEntry 5}
fadmConnChassisID OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Chassis ID of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the chassis Id of the local node"
::= { fadmPortEntry 6}
fadmConnSystemName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Name of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the sysetem name of the local node."
::= { fadmPortEntry 7}
fadmConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Module type connected to fadm port."
::= { fadmPortEntry 8}
fadmConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Conn port for FADM's port. Possible values based on
card types that can be connected to are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx."
::= { fadmPortEntry 9 }
fadmConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2."
::= { fadmPortEntry 10 }
fadmConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to. To delete a
connection associated with a specified port, set this
variable to 0."
::= { fadmPortEntry 11 }
-- The elements in the oppm subgroup of the configuration group
oppmBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the oppm Boot PROM code"
::= { oppm 1 }
oppmROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { oppm 2 }
oppmNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { oppm 3 }
oppmSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF OppmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { oppm 4 }
oppmSubDivEntry OBJECT-TYPE
SYNTAX OppmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oppmSubDivIndex }
::= { oppmSubDivTable 1 }
OppmSubDivEntry ::=
SEQUENCE
{
oppmSubDivIndex INTEGER,
oppmSubDivDescr DisplayString,
oppmSubDivSize INTEGER,
oppmSubDivOffset OCTET STRING
}
oppmSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { oppmSubDivEntry 1 }
oppmSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { oppmSubDivEntry 2 }
oppmSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { oppmSubDivEntry 3 }
oppmSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { oppmSubDivEntry 4 }
oppmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of OPPM rows in the following table. This
number is automatically updated whenever a new row is
added to the table below."
::= { oppm 5 }
oppmTable OBJECT-TYPE
SYNTAX SEQUENCE OF OppmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
OPPM card"
::= { oppm 6 }
oppmEntry OBJECT-TYPE
SYNTAX OppmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oppmCardLocation, oppmCardShelf, oppmCardSlot }
::= { oppmTable 1 }
OppmEntry ::=
SEQUENCE
{
oppmCardLocation CardLocation,
oppmCardShelf CardShelf,
oppmCardSlot INTEGER,
oppmModelNum DisplayString,
oppmMfgDate DateAndTime,
oppmSerialNum SerialString,
oppmModelType INTEGER,
oppmName CardName,
oppmFWVersionID VersionString,
oppmSetState RebootType,
oppmTxInsertLoss DisplayString,
oppmRxInsertLoss DisplayString,
oppmUpgradeFlag INTEGER,
oppmSwitch INTEGER,
oppmMarginForSwitch INTEGER,
oppmHighAlarmMargin INTEGER,
oppmConfigCommit INTEGER,
oppmHWName CardName,
oppmLinkAPathID PathIdName,
oppmLinkBPathID PathIdName,
oppmAdminState INTEGER,
oppmCleiNum DisplayString,
oppmSwitchState INTEGER
}
oppmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Location of the OPPM card. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { oppmEntry 1 }
oppmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2"
::= { oppmEntry 2 }
oppmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { oppmEntry 3 }
oppmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Oppm's model number."
::= { oppmEntry 4 }
oppmMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the OPPM card"
::= { oppmEntry 5 }
oppmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Serial # of the OPPM card."
::= { oppmEntry 6 }
oppmModelType OBJECT-TYPE
SYNTAX CardType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Model type of the OPPM"
::= { oppmEntry 7 }
oppmName OBJECT-TYPE
SYNTAX CardName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display (Network) name of the OPPM Card"
::= { oppmEntry 8 }
oppmFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the OPPM FW code"
::= { oppmEntry 9 }
oppmSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Instruct the oppm to do a warmboot. A get on this will
always return an other."
::= { oppmEntry 10 }
oppmTxInsertLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Transmit insertion loss."
::= { oppmEntry 12 }
oppmRxInsertLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
" Receive insertion loss."
::= { oppmEntry 13 }
oppmUpgradeFlag OBJECT-TYPE
SYNTAX INTEGER { upgradable(1), notUpgradable(2) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The oppm card's status is upgradable or not."
::= {oppmEntry 14 }
oppmSwitch OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
switchToLinkA(2),
switchToLinkB(3),
toggle(4),
enableAutoSwitch(6)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"instruct the OPPM to take on an
action, such as: switch to link A or link B
A get would alway return other(1)."
::= { oppmEntry 15 }
oppmMarginForSwitch OBJECT-TYPE
SYNTAX INTEGER (5..15)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configurable switching margin in dB
for protection switch to occur."
::= { oppmEntry 16 }
oppmHighAlarmMargin OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"High alarm margin for input signal strength
displayed in dB unit "
::= { oppmEntry 17 }
oppmConfigCommit OBJECT-TYPE
SYNTAX INTEGER { other(1), save(2) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This allows the current module configuration,
such as oppmMarginForSwitch, to be
stored in permanent storage."
::= { oppmEntry 18 }
oppmHWName OBJECT-TYPE
SYNTAX CardName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Hardware name of the OPPM Card."
::= { oppmEntry 19 }
oppmLinkAPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Oppmm LinkA Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { oppmEntry 20 }
oppmLinkBPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Oppm LinkB Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { oppmEntry 21 }
oppmAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Administrative control over that oppm card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { oppmEntry 22 }
oppmCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"CLEI number of the oppm Card."
::= { oppmEntry 23 }
oppmSwitchState OBJECT-TYPE
SYNTAX INTEGER { auto(1), forced(2) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The switching state. Switching state may be
either auto or forced. The auto state means
automatic switching is enabled. Forced state
means swithcing is disabled and has been forced
to the current active link."
::= { oppmEntry 24 }
oppmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OppmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the physical connection for each
OPPM card's port."
::= { oppm 7 }
oppmPortEntry OBJECT-TYPE
SYNTAX OppmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oppmPortCardShelf, oppmPortCardSlot, oppmPortType }
::= { oppmPortTable 1 }
OppmPortEntry ::=
SEQUENCE
{
oppmPortCardShelf CardShelf,
oppmPortCardSlot INTEGER,
oppmPortType INTEGER,
oppmConnLocation CardLocation,
oppmConnIpAddress IpAddress,
oppmConnChassisID NodeName,
oppmConnSystemName NodeName,
oppmConnCardType INTEGER,
oppmConnPort INTEGER,
oppmConnShelf INTEGER,
oppmConnSlot INTEGER
}
oppmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { oppmPortEntry 1 }
oppmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { oppmPortEntry 2 }
oppmPortType OBJECT-TYPE
SYNTAX INTEGER
{
linkATx(1),
linkARx(2),
linkBTx(3),
linkBRx(4),
localTx(5),
localRx(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of the OPPM's port."
::= { oppmPortEntry 3 }
oppmConnLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The chassis's location of the card conn to."
::= { oppmPortEntry 4 }
oppmConnIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"IpAddress of the connected node. User config. If local
connection, a set on it would return an error; would be automatically
be set to the IP address of the node "
::= { oppmPortEntry 5}
oppmConnChassisID OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..16))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Chassis ID of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the chassis Id of the local node"
::= { oppmPortEntry 6}
oppmConnSystemName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System Name of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the sysetem name of the local node."
::= { oppmPortEntry 7}
oppmConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Module type connected to oppm port."
::= { oppmPortEntry 8}
oppmConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Conn port for OPPM's port. Possible values based on
card types that can connect to OPPM are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx."
::= { oppmPortEntry 9 }
oppmConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2."
::= { oppmPortEntry 10 }
oppmConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to. To delete a
connection associated with a specified port, set this
variable to 0."
::= { oppmPortEntry 11 }
-- The table of mcm, applied to MCMT1 and MCME1
mcmBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the mcmt1/mcme1 Boot PROM code"
::= { mcm 1 }
mcmROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { mcm 2 }
mcmNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { mcm 3 }
mcmSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { mcm 4 }
mcmSubDivEntry OBJECT-TYPE
SYNTAX McmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmSubDivIndex }
::= { mcmSubDivTable 1 }
McmSubDivEntry ::=
SEQUENCE
{
mcmSubDivIndex INTEGER,
mcmSubDivDescr DisplayString,
mcmSubDivSize INTEGER,
mcmSubDivOffset OCTET STRING
}
mcmSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { mcmSubDivEntry 1 }
mcmSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { mcmSubDivEntry 2 }
mcmSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { mcmSubDivEntry 3 }
mcmSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { mcmSubDivEntry 4 }
mcmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of ADM rows in the following table. This number
is automatically updated whenever a new row is added
to the table below."
::= { mcm 5 }
mcmTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
mcmt1/mcme1 module"
::= { mcm 6 }
mcmEntry OBJECT-TYPE
SYNTAX McmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmCardLocation, mcmCardShelf, mcmCardSlot }
::= { mcmTable 1 }
McmEntry ::=
SEQUENCE
{
mcmCardLocation CardLocation,
mcmCardShelf CardShelf,
mcmCardSlot INTEGER,
mcmMfgDate DateAndTime,
mcmSerialNum SerialString,
mcmModelType INTEGER,
mcmName CardName,
mcmFWVersionID VersionString,
mcmAdminState INTEGER,
mcmLaserTemperature INTEGER,
mcmBandwidth INTEGER,
mcmSetState INTEGER,
mcmNumPorts INTEGER,
mcmUpgradeFlag INTEGER,
mcmEthernetStatus INTEGER,
mcmTimingPort INTEGER,
mcmModelNum DisplayString,
mcmMfgBiasCurrent INTEGER,
mcmMfgModulation INTEGER,
mcmMfgApc INTEGER,
mcmMfgIwmModulation INTEGER,
mcmconnMuxShelf INTEGER,
mcmconnMuxSlot INTEGER,
mcmconnMuxPort INTEGER,
mcmconnDemuxShelf INTEGER,
mcmconnDemuxSlot INTEGER,
mcmconnDemuxPort INTEGER,
mcmTimingPriority DisplayString,
mcmLinkName LinkName,
mcmEthernetMode INTEGER,
mcmHWName CardName,
mcmLinkWaveLength DisplayString,
mcmFpgaVersionID VersionString,
mcmPathID PathIdName,
mcmCleiNum DisplayString,
mcmItuNum DisplayString
}
mcmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the mcmt1/mcme1 Module."
::= { mcmEntry 1 }
mcmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the mcmt1/mcme1 is in. Valid values are: 1..2"
::= { mcmEntry 2 }
mcmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 21 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { mcmEntry 3 }
mcmMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of calibration of the mcmt1/mcme1 card"
::= { mcmEntry 4 }
mcmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the mcmt1/mcme1 card."
::= { mcmEntry 5 }
mcmModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the mcmt1/mcme1"
::= { mcmEntry 6 }
mcmName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Display (Network) name of the MCMT1/MCME1 Module"
::= { mcmEntry 7 }
mcmFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the MCMT1/MCME1 FW code"
::= { mcmEntry 8 }
mcmAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that mcmt1/mcme1 card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { mcmEntry 9 }
mcmLaserTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Temperature of the Laser. Not yet supported"
::= { mcmEntry 10 }
mcmBandwidth OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
oc3(2),
oc12(3),
oc48(4),
gbEthernet(5),
fibreChannel(6)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"mcmt1/mcme1 module's line rate."
::= { mcmEntry 11 }
mcmSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
resetWithCurrentConfiguration(2),
resetWithFactoryDefault(3),
nearEndCardLoopback(4),
networkCardLoopback(5),
nearEndPort1Loopback(6),
nearEndPort2Loopback(7),
nearEndPort3Loopback(8),
nearEndPort4Loopback(9),
networkPort1Loopback(10),
networkPort2Loopback(11),
networkPort3Loopback(12),
networkPort4Loopback(13),
disableLoopback(14)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the mcmt1/mcme1 card to do either a reset or loopback.
A get on this will always return an other."
::= { mcmEntry 12 }
mcmNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers of MCMT1/MCME1 module."
::= { mcmEntry 13 }
mcmUpgradeFlag OBJECT-TYPE
SYNTAX INTEGER { upgradable(1), notUpgradable(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MCMT1/MCME1 module's status is upgradable or not."
::= { mcmEntry 14 }
mcmEthernetStatus OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The MCMT1/MCME1 module's Ethernet status is down or up."
::= { mcmEntry 15 }
mcmTimingPort OBJECT-TYPE
SYNTAX INTEGER
{
internal(1),
link(2),
t1Port1(3),
t1Port2(4),
t1Port3(5),
t1Port4(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MCMT1/MCME1 module's port clock src"
::= { mcmEntry 16 }
mcmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mcmt1/mcme1 port's model number"
::= { mcmEntry 17 }
mcmMfgBiasCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bias current for the optical laser. This is the
preset manufacturing value"
::= { mcmEntry 18 }
mcmMfgModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency modulation for the optical laser. This
value is the preset manufacturing value."
::= { mcmEntry 19 }
mcmMfgApc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The APC value. This value is the preset
manufacturing value"
::= { mcmEntry 20 }
mcmMfgIwmModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency modulation for the IWM channel. This
value is the preset manufacturing value"
::= { mcmEntry 21 }
mcmconnMuxShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected mux shelf."
::= { mcmEntry 22 }
mcmconnMuxSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected mux slot."
::= { mcmEntry 23 }
mcmconnMuxPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected mux port. "
::= { mcmEntry 24 }
mcmconnDemuxShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected demux shelf."
::= { mcmEntry 25 }
mcmconnDemuxSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected demux slot."
::= { mcmEntry 26 }
mcmconnDemuxPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected demux port. "
::= { mcmEntry 27 }
mcmTimingPriority OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..12))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The clock source priority in descending order
in the format of a,b,c,d,e,f in which a
through f should be replaced with 1 through 6
which has the same meaning as the options of
mcmTimingPort and are repeated as follows:
0 - unknown
1 - internal
2 - link
3 - t1Port1
4 - t1Port2
5 - t1Port3
6 - t1Port4
For example, '2,5,4,6,3,1' will set the priority
of the clock source with link first, followed by
t1Port3, followed by t1Port2, followed by t1Port4,
followed by t1Port1, followed by internal."
::= { mcmEntry 28 }
mcmLinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable Link name for the connection
between the local and remote MCM/MCME1 Modules"
::= { mcmEntry 29 }
mcmEthernetMode OBJECT-TYPE
SYNTAX INTEGER { auto(1), forced10M(2), forced100M(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This allows the ethernet mode configured as
auto detect, forced 10M, or forced 100M."
::= { mcmEntry 30 }
mcmHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Hardware name of the MCMT1/MCME1 Card."
::= { mcmEntry 31 }
mcmLinkWaveLength OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link Wavelength of the MCMT1/MCME1 card"
::= { mcmEntry 32 }
mcmFpgaVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the MCMT1/MCME1 FPGA."
::= { mcmEntry 33 }
mcmPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { mcmEntry 34 }
mcmCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the mcmt1/mcme1 Card."
::= { mcmEntry 35 }
mcmItuNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"ITU number of the mcmt1/mcme1 Card."
::= { mcmEntry 36 }
mcmPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of MCMT1/MCME1 rows in the following table. This
number is automatically updated whenever a new row is
added to the table below."
::= { mcm 7 }
mcmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
MCMT1/MCME1 module's port."
::= { mcm 8 }
mcmPortEntry OBJECT-TYPE
SYNTAX McmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmPortCardLocation, mcmPortCardShelf,
mcmPortCardSlot, mcmPortIndex }
::= { mcmPortTable 1 }
McmPortEntry ::=
SEQUENCE
{
mcmPortCardLocation CardLocation,
mcmPortCardShelf CardShelf,
mcmPortCardSlot INTEGER,
mcmPortIndex INTEGER,
mcmPortConnection INTEGER,
mcmPortFraming INTEGER,
mcmPortLineCoding INTEGER,
mcmPortLineEqualizer INTEGER,
mcmPortImpedance INTEGER
}
mcmPortCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the MCMT1/MCME1 port. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { mcmPortEntry 1 }
mcmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1..2."
::= { mcmPortEntry 2 }
mcmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the Module is in. Valid
values are: 1 to 17"
::= { mcmPortEntry 3 }
mcmPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port's index."
::= { mcmPortEntry 4 }
mcmPortConnection OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port's connection status."
::= { mcmPortEntry 5 }
mcmPortFraming OBJECT-TYPE
SYNTAX INTEGER { esf(1), d4(2), crc4(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of framing. esf(1) and d4(2) are for mcmt1. crc4(3) is for mcme1.
For mcme1, this release of hardware and software only supports fixed
configuration, CRC4, hence, operation of setting will return an
error."
::= { mcmPortEntry 6 }
mcmPortLineCoding OBJECT-TYPE
SYNTAX INTEGER { b8zs(1), ami(2), hdb3(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of line coding. b8zs(1) and ami(2) are for mcmt1. hdb3(3) is for mcme1.
For mcme1, this release of hardware and software only supports fixed
configuration, HDB3, hence, operation of setting will return an
error."
::= { mcmPortEntry 7 }
mcmPortLineEqualizer OBJECT-TYPE
SYNTAX INTEGER { ft0to133(1), ft133to266(2), ft266to399(3), ft399to533(4),
ft533to655(5), minus43dB(6) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Line equilizer. ft0to133(1), ft133to266(2), ft266to399(3),
ft399to533(4), and ft533to655(5) are for mcmt1. minus43dB(6) is for mcme1.
For mcme1, this release of hardware and software only supports fixed
configuration, -43dB, hence, operation of setting will return an
error."
::= { mcmPortEntry 8 }
mcmPortImpedance OBJECT-TYPE
SYNTAX INTEGER { ohms-100(1), ohms-75(2), ohms-120(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port impedance. ohms-100(1) is for mcmt1. ohms-75(2) and ohms-120(3)
are for mcme1.
For mcme1, this release of hardware and software only supports fixed
configuration, 75 ohm, hence, operation of setting will return an
error."
::= { mcmPortEntry 9 }
-- The elements in the fn subgroup of the configuration group
fnNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of fn rows in the following table. This number
is automatically updated whenever a new row is added
to the table below."
::= { fn 1 }
fnTable OBJECT-TYPE
SYNTAX SEQUENCE OF FnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each fn."
::= { fn 2 }
fnEntry OBJECT-TYPE
SYNTAX FnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fnID }
::= { fnTable 1 }
FnEntry ::=
SEQUENCE
{
fnID INTEGER,
fnMfgDate DateAndTime,
fnSerialNum SerialString,
fnModelType ModelString
}
fnID OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot ID the fn is in. Valid values are: 1 to 4"
::= { fnEntry 1 }
fnMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the fn"
::= { fnEntry 2 }
fnSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Serial # of the fn. Not Supported Yet."
::= { fnEntry 3 }
fnModelType OBJECT-TYPE
SYNTAX ModelString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Model type of the fn. Up to 10 characters.
Not Supported Yet."
::= { fnEntry 4 }
--The elements in the csim subgroup of the configuration group
csimSysMode OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2), other(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ColorSim Mode of the Chassis. The value Enable
means that the ColorSim feature is enabled for
all the interface cards. An action element, returns other on
a get request."
::= { csim 1 }
csimTable OBJECT-TYPE
SYNTAX SEQUENCE OF CsimEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry in this table represents the
information for each colorsim card."
::= { csim 2 }
csimEntry OBJECT-TYPE
SYNTAX CsimEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below."
INDEX { csimLocation, csimShelf, csimSlot }
::= { csimTable 1 }
CsimEntry ::=
SEQUENCE
{
csimLocation CardLocation,
csimShelf CardShelf,
csimSlot INTEGER,
csimMode INTEGER,
csimDCMode INTEGER,
csimGatingIntvl INTEGER,
csimUpdtIntvl INTEGER,
csimSEIThreshold DisplayString
}
csimLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the card. Valid values are: Local in
the same chassis, or remote to this chassis."
::= { csimEntry 1 }
csimShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { csimEntry 2 }
csimSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This card occupies two slots currently."
::= { csimEntry 3 }
csimMode OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Mode of ColorSIM for this entry. The Modes
are Enable or Disable."
::= { csimEntry 4 }
csimDCMode OBJECT-TYPE
SYNTAX INTEGER { standard(1), continuous(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Data Collection Mode of ColorSIM."
::= { csimEntry 5 }
csimGatingIntvl OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Gating Interval in seconds in which
the incoming data stream is being monitored
for errors."
::= { csimEntry 6 }
csimUpdtIntvl OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of gating intervals to be processed before
the data is logged for reporting purposes."
::= { csimEntry 7 }
csimSEIThreshold OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The SEI Threshold of ColorSIM specifies the
maximum number of errored bits that may have
occurred during a single gating interval before
the interval is considered Severely Errorred.
The Threshold values are in the form of
x.ye-z."
::= { csimEntry 8 }
-- The elements in the rpsm subgroup of the configuration group
rpsmBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the rpsm
Boot PROM code"
::= { rpsm 1 }
rpsmROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { rpsm 2 }
rpsmNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { rpsm 3 }
rpsmSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpsmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { rpsm 4 }
rpsmSubDivEntry OBJECT-TYPE
SYNTAX RpsmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rpsmSubDivIndex }
::= { rpsmSubDivTable 1 }
RpsmSubDivEntry ::=
SEQUENCE
{
rpsmSubDivIndex INTEGER,
rpsmSubDivDescr DisplayString,
rpsmSubDivSize INTEGER,
rpsmSubDivOffset OCTET STRING
}
rpsmSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { rpsmSubDivEntry 1 }
rpsmSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { rpsmSubDivEntry 2 }
rpsmSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { rpsmSubDivEntry 3 }
rpsmSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { rpsmSubDivEntry 4 }
rpsmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of RPSM rows in the following table. This
number is automatically updated whenever a new row is
added to the table below."
::= { rpsm 5 }
rpsmTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpsmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
RPSM card"
::= { rpsm 6 }
rpsmEntry OBJECT-TYPE
SYNTAX RpsmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rpsmCardLocation, rpsmCardShelf, rpsmCardSlot }
::= { rpsmTable 1 }
RpsmEntry ::=
SEQUENCE
{
rpsmCardLocation CardLocation,
rpsmCardShelf CardShelf,
rpsmCardSlot INTEGER,
rpsmModelNum DisplayString,
rpsmOpticsMfgDate DateAndTime,
rpsmSerialNum SerialString,
rpsmModelType INTEGER,
rpsmHWName CardName,
rpsmFWVersionID VersionString,
rpsmCardName CardName,
rpsmFWName DisplayString,
rpsmFWDate DateAndTime,
rpsmHWVersionID VersionString,
rpsmHWDate DateAndTime,
rpsmSetState RebootType,
rpsmExpressLoss DisplayString,
rpsmMarginForSwitch INTEGER,
rpsmMinProtPowerForSwitch INTEGER,
rpsmDeBounce INTEGER,
rpsmBlackOutTime INTEGER,
rpsmSwitch INTEGER,
rpsmAddDropLoss DisplayString,
rpsmPathID PathIdName,
rpsmAdminState INTEGER
}
rpsmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Location of the RPSM card. Valid values are: Local in
the same chassis, or remote to this chassis."
::= { rpsmEntry 1 }
rpsmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { rpsmEntry 2 }
rpsmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { rpsmEntry 3 }
rpsmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RPSM's model number."
::= { rpsmEntry 4 }
rpsmOpticsMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the optics
on the RPSM card."
::= { rpsmEntry 5 }
rpsmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Serial # of the RPSM card."
::= { rpsmEntry 6 }
rpsmModelType OBJECT-TYPE
SYNTAX INTEGER { rpsm(17) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Model type of the RPSM."
::= { rpsmEntry 7 }
rpsmHWName OBJECT-TYPE
SYNTAX CardName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Manufacturing Hardware name of the RPSM Card."
::= { rpsmEntry 8 }
rpsmFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the RPSM FW code"
::= { rpsmEntry 9 }
rpsmCardName OBJECT-TYPE
SYNTAX CardName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User configurable card name."
::= { rpsmEntry 10 }
rpsmFWName OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RPSM's Firmware Name."
::= { rpsmEntry 11 }
rpsmFWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of latest Firmware of the RPSM card."
::= { rpsmEntry 12 }
rpsmHWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the RPSM HW code."
::= { rpsmEntry 13 }
rpsmHWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of Hardware of the RPSM card."
::= { rpsmEntry 14 }
rpsmSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Instruct the rpsm to do a warmboot. A get on this will
always return an other."
::= { rpsmEntry 15 }
rpsmExpressLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Insertion loss for the expressed channel
through the RPSM module in dB."
::= { rpsmEntry 16 }
rpsmMarginForSwitch OBJECT-TYPE
SYNTAX INTEGER (-40..0)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Switching threshold in dB for protection
switch to occur."
::= { rpsmEntry 17 }
rpsmMinProtPowerForSwitch OBJECT-TYPE
SYNTAX INTEGER (-40..0)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Minimum protection link's light power in dBm
to allow protection switching to occur."
::= { rpsmEntry 18 }
rpsmDeBounce OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Debounce in number of times to measure
low light power before protection switch."
::= { rpsmEntry 19 }
rpsmBlackOutTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Black out time in unit of 0.1 second after
protection switch to allow another protection
switch to occur again."
::= { rpsmEntry 20 }
rpsmSwitch OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
switchToLinkA(2),
switchToLinkB(3),
toggle(4),
enableAutoSwitch(6)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"instruct the RPSM to take on an action,
such as: switch to link A or link B.
A get would alway return other(1)."
::= { rpsmEntry 21 }
rpsmAddDropLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Insertion loss of the Add/Drop path
through the RPSM module in dB."
::= { rpsmEntry 22 }
rpsmPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { rpsmEntry 23 }
rpsmAdminState OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2),
na(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Administrative control over that rpsm card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { rpsmEntry 24}
rpsmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpsmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the physical connection for each
RPSM card's port."
::= { rpsm 7 }
rpsmPortEntry OBJECT-TYPE
SYNTAX RpsmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rpsmPortCardShelf, rpsmPortCardSlot, rpsmPortType }
::= { rpsmPortTable 1 }
RpsmPortEntry ::=
SEQUENCE
{
rpsmPortCardShelf CardShelf,
rpsmPortCardSlot SlotInput,
rpsmPortType INTEGER,
rpsmConnCardType INTEGER,
rpsmConnPort INTEGER,
rpsmConnShelf ShelfInput,
rpsmConnSlot SlotInput
}
rpsmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { rpsmPortEntry 1 }
rpsmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rpsmPortEntry 2 }
rpsmPortType OBJECT-TYPE
SYNTAX INTEGER
{
linkEast(1),
linkWest(2),
in(3),
out(4),
aTOd(5),
exp(6)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Type of the RPSM's port. The order is CLI compatible."
::= { rpsmPortEntry 3 }
rpsmConnCardType OBJECT-TYPE
SYNTAX INTEGER (0..30)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Type of connection. Valid values are ocmu(2),
ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21),
osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc...
A zero will be used for no connections."
::= { rpsmPortEntry 4}
rpsmConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Conn port for RPSM's port.Possible values based on
card types that can connect to RPSM are:
OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN
W4CM/W4CD: 1=1510, 2=1530, 3=1550,
4=1570, 5=EXP, 6=IN/OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
OSAM: 1=IN, 2=OUT
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx
OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx "
::= { rpsmPortEntry 5 }
rpsmConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2."
::= { rpsmPortEntry 6 }
rpsmConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to."
::= { rpsmPortEntry 7 }
-- The elements in the rsdm subgroup of the configuration group
rsdmBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the rsdm Boot PROM code"
::= { rsdm 1 }
rsdmROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { rsdm 2 }
rsdmNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { rsdm 3 }
rsdmSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsdmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { rsdm 4 }
rsdmSubDivEntry OBJECT-TYPE
SYNTAX RsdmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsdmSubDivIndex }
::= { rsdmSubDivTable 1 }
RsdmSubDivEntry ::=
SEQUENCE
{
rsdmSubDivIndex INTEGER,
rsdmSubDivDescr DisplayString,
rsdmSubDivSize INTEGER,
rsdmSubDivOffset OCTET STRING
}
rsdmSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { rsdmSubDivEntry 1 }
rsdmSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { rsdmSubDivEntry 2 }
rsdmSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { rsdmSubDivEntry 3 }
rsdmSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { rsdmSubDivEntry 4 }
rsdmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of RSDM rows in the following table. This
number is automatically updated whenever a new row is
added to the table below."
::= { rsdm 5 }
rsdmTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsdmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
RSDM card"
::= { rsdm 6 }
rsdmEntry OBJECT-TYPE
SYNTAX RsdmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsdmCardLocation, rsdmCardShelf, rsdmCardSlot }
::= { rsdmTable 1 }
RsdmEntry ::=
SEQUENCE
{
rsdmCardLocation CardLocation,
rsdmCardShelf CardShelf,
rsdmCardSlot INTEGER,
rsdmModelNum DisplayString,
rsdmOpticsMfgDate DateAndTime,
rsdmSerialNum SerialString,
rsdmModelType INTEGER,
rsdmHWName CardName,
rsdmCardName CardName,
rsdmFWVersionID VersionString,
rsdmFWName DisplayString,
rsdmFWDate DateAndTime,
rsdmHWVersionID VersionString,
rsdmHWDate DateAndTime,
rsdmSetState RebootType,
rsdmRxITUNumber INTEGER,
rsdmTxITUNumber INTEGER,
rsdmRxInsertionLoss DisplayString,
rsdmTxInsertionLoss DisplayString,
rsdmExpressLoss DisplayString,
rsdmMarginForSwitch INTEGER,
rsdmMinProtPowerForSwitch INTEGER,
rsdmDeBounce INTEGER,
rsdmBlackOutTime INTEGER,
rsdmSwitch INTEGER,
rsdmPathID PathIdName,
rsdmAdminState INTEGER
}
rsdmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Location of the RSDM card. Valid values are: Local in
the same chassis, or remote to this chassis."
::= { rsdmEntry 1 }
rsdmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2"
::= { rsdmEntry 2 }
rsdmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { rsdmEntry 3 }
rsdmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RSDM's model number."
::= { rsdmEntry 4 }
rsdmOpticsMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the optics on
the RSDM card."
::= { rsdmEntry 5 }
rsdmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Serial # of the RSDM card."
::= { rsdmEntry 6 }
rsdmModelType OBJECT-TYPE
SYNTAX INTEGER { rsdm(16) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Model type of the RSDM."
::= { rsdmEntry 7 }
rsdmHWName OBJECT-TYPE
SYNTAX CardName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Hardware name of the RSDM Card."
::= { rsdmEntry 8 }
rsdmCardName OBJECT-TYPE
SYNTAX CardName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User configurable name of the RSDM Card."
::= { rsdmEntry 9 }
rsdmFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the RSDM FW code"
::= { rsdmEntry 10 }
rsdmFWName OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RSDM's Firmware Name."
::= { rsdmEntry 11 }
rsdmFWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of latest Firmware of the RSDM card."
::= { rsdmEntry 12 }
rsdmHWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the RSDM HW code."
::= { rsdmEntry 13 }
rsdmHWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of Hardware of the RSDM card."
::= { rsdmEntry 14 }
rsdmSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Instruct the rsdm to do a warmboot. A get on this will
always return an other."
::= { rsdmEntry 15 }
rsdmRxITUNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Receive port's ITU wavelength number."
::= { rsdmEntry 16 }
rsdmTxITUNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Transmit port's ITU wavelength number."
::= { rsdmEntry 17 }
rsdmRxInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Receive port's insertion loss in dB."
::= { rsdmEntry 18 }
rsdmTxInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Transmit port's insertion loss in dB."
::= { rsdmEntry 19 }
rsdmExpressLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Insertion loss for the expressed channel
through the RSDM module in dB."
::= { rsdmEntry 20 }
rsdmMarginForSwitch OBJECT-TYPE
SYNTAX INTEGER (-40..0)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Switching threshold in dB for protection
switch to occur."
::= { rsdmEntry 21 }
rsdmMinProtPowerForSwitch OBJECT-TYPE
SYNTAX INTEGER (-40..0)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Minimum protection link's light power in dBm
to allow protection switching to occur."
::= { rsdmEntry 22 }
rsdmDeBounce OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Debounce in number of times to measure
low light power before protection switch."
::= { rsdmEntry 23 }
rsdmBlackOutTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Black out time in unit of 0.1 second after
protection switch to allow another protection
switch to occur again."
::= { rsdmEntry 24 }
rsdmSwitch OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
switchToLinkA(2),
switchToLinkB(3),
toggle(4),
enableAutoSwitch(6)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Instruct the RSDM to take on an action,
such as: switch to link A or link B.
A snmp get would always return other(1)."
::= { rsdmEntry 25 }
rsdmPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { rsdmEntry 26 }
rsdmAdminState OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2),
na(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Administrative control over that rsdm card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { rsdmEntry 27 }
rsdmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsdmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the physical connection for each
RSDM card's port."
::= { rsdm 7 }
rsdmPortEntry OBJECT-TYPE
SYNTAX RsdmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsdmPortCardShelf, rsdmPortCardSlot, rsdmPortType }
::= { rsdmPortTable 1 }
RsdmPortEntry ::=
SEQUENCE
{
rsdmPortCardShelf CardShelf,
rsdmPortCardSlot SlotInput,
rsdmPortType INTEGER,
rsdmConnCardType CardType,
rsdmConnPort INTEGER,
rsdmConnShelf ShelfInput,
rsdmConnSlot SlotInput
}
rsdmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { rsdmPortEntry 1 }
rsdmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rsdmPortEntry 2 }
rsdmPortType OBJECT-TYPE
SYNTAX INTEGER
{
linkEast(1),
linkWest(2),
linkRx(3),
linkTx(4)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Type of the RSDM's port. The order is CLI compatible."
::= { rsdmPortEntry 3 }
rsdmConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Type of connection. Valid values are ocmu(2),
ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21),
osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc...
A zero will be used for no connections."
::= { rsdmPortEntry 4}
rsdmConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Conn port for RSDM's port.Possible values based on
card types that can connect to RSDM are:
OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN
W4CM/W4CD: 1=1510, 2=1530, 3=1550,
4=1570, 5=EXP, 6=IN/OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
OSAM: 1=IN, 2=OUT
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx
OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx "
::= { rsdmPortEntry 5 }
rsdmConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2."
::= { rsdmPortEntry 6 }
rsdmConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to."
::= { rsdmPortEntry 7 }
-- The elements in the rtdm subgroup of the configuration group
rtdmBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the RTDM Boot PROM code"
::= { rtdm 1 }
rtdmROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { rtdm 2 }
rtdmNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { rtdm 3 }
rtdmSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtdmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { rtdm 4 }
rtdmSubDivEntry OBJECT-TYPE
SYNTAX RtdmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rtdmSubDivIndex }
::= { rtdmSubDivTable 1 }
RtdmSubDivEntry ::=
SEQUENCE
{
rtdmSubDivIndex INTEGER,
rtdmSubDivDescr DisplayString,
rtdmSubDivSize INTEGER,
rtdmSubDivOffset OCTET STRING
}
rtdmSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { rtdmSubDivEntry 1 }
rtdmSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { rtdmSubDivEntry 2 }
rtdmSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { rtdmSubDivEntry 3 }
rtdmSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { rtdmSubDivEntry 4 }
rtdmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of RTDM rows in the following table. This number
is automatically updated whenever a new row is added
to the table below."
::= { rtdm 5 }
rtdmTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtdmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
RTDM card"
::= { rtdm 6 }
rtdmEntry OBJECT-TYPE
SYNTAX RtdmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rtdmCardLocation, rtdmCardShelf, rtdmCardSlot }
::= { rtdmTable 1 }
RtdmEntry ::=
SEQUENCE
{
rtdmCardLocation CardLocation,
rtdmCardShelf CardShelf,
rtdmCardSlot INTEGER,
rtdmModelNum DisplayString,
rtdmOpticsMfgDate DateAndTime,
rtdmSerialNum SerialString,
rtdmModelType INTEGER,
rtdmHWName CardName,
rtdmFWVersionID VersionString,
rtdmCardName CardName,
rtdmFWName DisplayString,
rtdmFWDate DateAndTime,
rtdmHWVersionID VersionString,
rtdmHWDate DateAndTime,
rtdmSetState RebootType,
rtdmCommonEInsertionLoss DisplayString,
rtdmCommonWInsertionLoss DisplayString,
rtdmMonEastInsertionLoss DisplayString,
rtdmMonWestInsertionLoss DisplayString,
rtdmPathID PathIdName,
rtdmAdminState INTEGER
}
rtdmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Location of the RTDM card. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { rtdmEntry 1 }
rtdmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { rtdmEntry 2 }
rtdmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { rtdmEntry 3 }
rtdmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Model number for RTDM."
::= { rtdmEntry 4 }
rtdmOpticsMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the optics
on the RTDM card"
::= { rtdmEntry 5 }
rtdmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Serial # of the RTDM card."
::= { rtdmEntry 6 }
rtdmModelType OBJECT-TYPE
SYNTAX INTEGER { rtdm(18) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Model type of the RTDM"
::= { rtdmEntry 7 }
rtdmHWName OBJECT-TYPE
SYNTAX CardName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display (Network) name of the RTDM Card"
::= { rtdmEntry 8 }
rtdmFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the RTDM FW code"
::= { rtdmEntry 9 }
rtdmCardName OBJECT-TYPE
SYNTAX CardName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"User configurable card name."
::= { rtdmEntry 10 }
rtdmFWName OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"RTDM's Firmware Name."
::= { rtdmEntry 11 }
rtdmFWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of latest Firmware of the RTDM card"
::= { rtdmEntry 12 }
rtdmHWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the RTDM HW code"
::= { rtdmEntry 13 }
rtdmHWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of Hardware of the RTDM card"
::= { rtdmEntry 14 }
rtdmSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Instruct the rtdm to do a warmboot. A get on this will
always return an other."
::= { rtdmEntry 15 }
rtdmCommonEInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The RTDM Common path East's insertion loss in dB."
::= { rtdmEntry 16 }
rtdmCommonWInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The RTDM Common path West's insertion loss in dB."
::= { rtdmEntry 17 }
rtdmMonEastInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The RTDM Monitor East Path's insertion loss
in dB."
::= { rtdmEntry 18 }
rtdmMonWestInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The RTDM Monitor West Path's insertion loss
in dB."
::= { rtdmEntry 19 }
rtdmPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { rtdmEntry 20 }
rtdmAdminState OBJECT-TYPE
SYNTAX INTEGER
{
disable(1),
enable(2),
na(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Administrative control over that rtdm card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { rtdmEntry 21 }
rtdmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtdmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the physical connection for each
RTDM card's port."
::= { rtdm 7 }
rtdmPortEntry OBJECT-TYPE
SYNTAX RtdmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rtdmPortCardShelf, rtdmPortCardSlot, rtdmPortType }
::= { rtdmPortTable 1 }
RtdmPortEntry ::=
SEQUENCE
{
rtdmPortCardShelf CardShelf,
rtdmPortCardSlot SlotInput,
rtdmPortType INTEGER,
rtdmConnCardType INTEGER,
rtdmConnPort INTEGER,
rtdmConnShelf ShelfInput,
rtdmConnSlot SlotInput
}
rtdmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { rtdmPortEntry 1 }
rtdmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rtdmPortEntry 2 }
rtdmPortType OBJECT-TYPE
SYNTAX INTEGER
{
localRx(1)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Type of the RTDM's port. The order is CLI compatible."
::= { rtdmPortEntry 3 }
rtdmConnCardType OBJECT-TYPE
SYNTAX INTEGER (0..30)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Type of connection. Valid values are ocmu(2),
ocmItu(3), mux(4), demux(5), mcm(8), w4cd(10), w2cmd(13), w4cm(21),
osam(20), fadm(6), oppm(7), fadmb(19), ocme(24), etc..."
::= { rtdmPortEntry 4}
rtdmConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Conn port for RTDM's port.Possible values based on
card types that can connect to RTDM are:
OFCM/OFCD: 1/2/3/4= port index, 5=EXP, 6=OUT/IN
W4CM/W4CD: 1=1510, 2=1530, 3=1550,
4=1570, 5=EXP, 6=IN/OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
OSAM: 1=IN, 2=OUT
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
FADMB: 1=A/D, 2=EXP, 3=Local, 4=Rx
OCMU/OCMITU/MCM: 1=Link Tx, 2=Link Rx
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx "
::= { rtdmPortEntry 5 }
rtdmConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2."
::= { rtdmPortEntry 6 }
rtdmConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to.
A zero will be used for no connections."
::= { rtdmPortEntry 7 }
-- The elements in the osam subgroup of the configuration group
osamBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the osam boot prom code."
::= { osam 1 }
osamROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobytes."
::= { osam 2 }
osamNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the ROM's subdivisions."
::= { osam 3 }
osamSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF OsamSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { osam 4 }
osamSubDivEntry OBJECT-TYPE
SYNTAX OsamSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { osamSubDivIndex }
::= { osamSubDivTable 1 }
OsamSubDivEntry ::=
SEQUENCE
{
osamSubDivIndex INTEGER,
osamSubDivDescr DisplayString,
osamSubDivSize INTEGER,
osamSubDivOffset OCTET STRING
}
osamSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each subdivision."
::= { osamSubDivEntry 1 }
osamSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display name of each subdivision."
::= { osamSubDivEntry 2 }
osamSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each subdivision in Kbytes."
::= { osamSubDivEntry 3 }
osamSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in HEX
format."
::= { osamSubDivEntry 4 }
osamNumber OBJECT-TYPE
SYNTAX INTEGER (0..32)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the osam table."
::= { osam 5 }
osamTable OBJECT-TYPE
SYNTAX SEQUENCE OF OsamEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
osam card"
::= { osam 6 }
osamEntry OBJECT-TYPE
SYNTAX OsamEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { osamCardLocation, osamCardShelf, osamCardSlot }
::= { osamTable 1 }
OsamEntry ::=
SEQUENCE
{
osamCardLocation CardLocation,
osamCardShelf CardShelf,
osamCardSlot INTEGER,
osamModelNum ModelNum,
osamSerialNum SerialString,
osamModelType INTEGER,
osamHWName CardName,
osamHWVersionID VersionString,
osamHWDate DateAndTime,
osamFWName CardName,
osamFWVersionID VersionString,
osamFWDate DateAndTime,
osamCardName CardName,
osamSetState RebootType,
osamLaserState FlagType,
osamOperationMode INTEGER,
osamLaserBiasCurrent INTEGER,
osamAmplifierGain INTEGER,
osamConfigCommit INTEGER,
osamNoiseFigure INTEGER,
osamPathID PathIdName,
osamAdminState INTEGER,
osam2NoiseFigure DisplayString,
osam2GainReq DisplayString,
osam2OpPowerReq DisplayString,
osamCleiNum DisplayString,
osamNumPorts INTEGER
}
osamCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { osamEntry 1 }
osamCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf number in which the module is plugged in."
::= { osamEntry 2 }
osamCardSlot OBJECT-TYPE
SYNTAX INTEGER (0..16)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot number in which the module is plugged in.
If a 0 is written into this mib element, the module
will be deleted from the system."
::= { osamEntry 3 }
osamModelNum OBJECT-TYPE
SYNTAX ModelNum
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturing model number of the module."
::= { osamEntry 4 }
osamSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Unique serial number of the module."
::= { osamEntry 5 }
osamModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { osamEntry 6 }
osamHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturing Hardware name of the module."
::= { osamEntry 7 }
osamHWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current hardware version string of the module."
::= { osamEntry 8 }
osamHWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date of manufacturing of the electronics portion of
the module."
::= { osamEntry 9 }
osamFWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturing Firmware name of the module."
::= { osamEntry 10 }
osamFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current firmware version string of the module."
::= { osamEntry 11 }
osamFWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Release date for the firmware of the module."
::= { osamEntry 12 }
osamCardName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable card name for the module."
::= { osamEntry 13 }
osamSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the osam module to do a reset.
A get on this will always return other."
::= { osamEntry 14 }
osamLaserState OBJECT-TYPE
SYNTAX FlagType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The operational state of the laser."
::= { osamEntry 15 }
osamOperationMode OBJECT-TYPE
SYNTAX INTEGER { currentControlled(1), gainControlled(2), powerControlled(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Operation mode of the module. powerControlled(3) is not
supported by OSAM modules. currentControlled(1) is not
supported OSAM-HP/LP modules."
::= { osamEntry 16 }
osamLaserBiasCurrent OBJECT-TYPE
SYNTAX INTEGER (40..200)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Constant current in mA to be used by the module when
the operation mode is set to currentControlled. This
value can't be set if operation mode is set to
gainControlled.
Applicable only to OSAM module"
::= { osamEntry 17 }
osamAmplifierGain OBJECT-TYPE
SYNTAX INTEGER (0..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Constant gain in dB to be used by the module when the
operation mode is set to gainControlled. This value
can't be set if operation mode is set to
currentControlled.
Not applicable to OSAM-HP/LP module"
::= { osamEntry 18 }
osamConfigCommit OBJECT-TYPE
SYNTAX INTEGER { other(1), save(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This allows the current module configuration to be
stored in permanent storage."
::= { osamEntry 19 }
osamNoiseFigure OBJECT-TYPE
SYNTAX INTEGER (0..10)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The calibrated noise figure of the gain block in dB.
Applicable only to OSAM module"
::= { osamEntry 20 }
osamPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { osamEntry 21 }
osamAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that osam card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { osamEntry 22 }
osam2NoiseFigure OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The calibrated noise figure of the gain block in dBm.
Applicable only to OSAM-HP/LP module"
::= { osamEntry 23 }
osam2GainReq OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Constant gain in dB to be used by the module when the
operation mode is set to gainControlled. This value
can't be set if operation mode is set to
powerControlled. Range is 0-16.5db(LP) and 0-23.3db(HP)
Applicable only to OSAM-HP/LP module"
::= { osamEntry 24 }
osam2OpPowerReq OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Constant output power in dBm to be used by the module when the
operation mode is set to powerControlled. This value
can't be set if operation mode is set to
gainControlled. Range is 0-9dbm (LP) and 0-18dbm(HP)
Applicable only to OSAM-HP/LP module"
::= { osamEntry 25 }
osamCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the osam Card."
::= { osamEntry 26 }
osamNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each OSAM card."
::= { osamEntry 27 }
osamPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OsamPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the physical connection for each
OSAM card's port."
::= { osam 7 }
osamPortEntry OBJECT-TYPE
SYNTAX OsamPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { osamPortCardShelf, osamPortCardSlot, osamPortType }
::= { osamPortTable 1 }
OsamPortEntry ::=
SEQUENCE
{
osamPortCardShelf CardShelf,
osamPortCardSlot INTEGER,
osamPortType INTEGER,
osamConnCardType CardType,
osamConnPort INTEGER,
osamConnShelf INTEGER,
osamConnSlot INTEGER,
osamPortCardType CardType,
osamConnLocation CardLocation,
osamConnChassisID DisplayString,
osamConnSystemName DisplayString,
osamConnIpAddress IpAddress
}
osamPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { osamPortEntry 1 }
osamPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { osamPortEntry 2 }
osamPortType OBJECT-TYPE
SYNTAX INTEGER { in(1), out(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of the OSAM's port."
::= { osamPortEntry 3 }
osamConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Module type connectioned to osam port."
::= { osamPortEntry 4}
osamConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Conn port for OSAM's port. Possible values based on
card types that can be connected to OSAM are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx."
::= { osamPortEntry 5 }
osamConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2."
::= { osamPortEntry 6 }
osamConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to. To delete a
connection associated with a specified port, set this
variable to 0."
::= { osamPortEntry 7 }
osamPortCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of OSAM module."
::= { osamPortEntry 8}
osamConnLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The chassis's location of the card connected to."
::= { osamPortEntry 9}
osamConnChassisID OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Chassis ID of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the chassis Id of the local node."
::= { osamPortEntry 10}
osamConnSystemName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Name of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the sysetem name of the local node."
::= { osamPortEntry 11}
osamConnIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IpAddress of the connected node. User config. If local
connection, a set on it would return an error; would be automatically
be set to the IP address of the node."
::= { osamPortEntry 12}
-- The elements in the rsm subgroup of the configuration group
rsmBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the rsm
Boot PROM code"
::= { rsm 1 }
rsmROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { rsm 2 }
rsmNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { rsm 3 }
rsmSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { rsm 4 }
rsmSubDivEntry OBJECT-TYPE
SYNTAX RsmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsmSubDivIndex }
::= { rsmSubDivTable 1 }
RsmSubDivEntry ::=
SEQUENCE
{
rsmSubDivIndex INTEGER,
rsmSubDivDescr DisplayString,
rsmSubDivSize INTEGER,
rsmSubDivOffset OCTET STRING
}
rsmSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { rsmSubDivEntry 1 }
rsmSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { rsmSubDivEntry 2 }
rsmSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { rsmSubDivEntry 3 }
rsmSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { rsmSubDivEntry 4 }
rsmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of RSM rows in the following table. This
number is automatically updated whenever a new row is
added to the table below."
::= { rsm 5 }
rsmTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
RSM card"
::= { rsm 6 }
rsmEntry OBJECT-TYPE
SYNTAX RsmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsmCardLocation, rsmCardShelf, rsmCardSlot }
::= { rsmTable 1 }
RsmEntry ::=
SEQUENCE
{
rsmCardLocation CardLocation,
rsmCardShelf CardShelf,
rsmCardSlot SlotInput,
rsmModelNum DisplayString,
rsmOpticsMfgDate DateAndTime,
rsmSerialNum SerialString,
rsmModelType INTEGER,
rsmHWName CardName,
rsmCardName CardName,
rsmFWName DisplayString,
rsmFWVersionID VersionString,
rsmFWDate DateAndTime,
rsmSetState RebootType,
rsmRxInsertionLoss DisplayString,
rsmRxComInsertionLoss DisplayString,
rsmWorkingWavelength INTEGER,
rsmLinkAPathID PathIdName,
rsmLinkBPathID PathIdName,
rsmAdminState INTEGER,
rsmCleiNum DisplayString,
rsmNumPorts INTEGER
}
rsmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the RSM card. Valid values are: Local in
the same chassis."
::= { rsmEntry 1 }
rsmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { rsmEntry 2 }
rsmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { rsmEntry 3 }
rsmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RSM's model number."
::= { rsmEntry 4 }
rsmOpticsMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the optics
on the RSM card."
::= { rsmEntry 5 }
rsmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the RSM card."
::= { rsmEntry 6 }
rsmModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the RSM."
::= { rsmEntry 7 }
rsmHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturing Hardware name of the RSM Card."
::= { rsmEntry 8 }
rsmCardName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable card name."
::= { rsmEntry 9 }
rsmFWName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"RSM's Firmware Name."
::= { rsmEntry 10 }
rsmFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the RSM FW code."
::= { rsmEntry 11 }
rsmFWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of latest Firmware of the RSM card."
::= { rsmEntry 12 }
rsmSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the rsm to do a warmboot. A get on this will
always return an other."
::= { rsmEntry 13 }
rsmRxInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Insertion loss for Rx Path."
::= { rsmEntry 14 }
rsmRxComInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Insertion loss for Rx Com Path."
::= { rsmEntry 15 }
rsmWorkingWavelength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The RSM ITU number."
::= { rsmEntry 16 }
rsmLinkAPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rsm LinkA Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { rsmEntry 17 }
rsmLinkBPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rsm LinkB Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { rsmEntry 18 }
rsmAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that rsm card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { rsmEntry 19 }
rsmCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the rsm Card."
::= { rsmEntry 20 }
rsmNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each RSM card."
::= { rsmEntry 21 }
rsmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
RSM card's port."
::= { rsm 7 }
rsmPortEntry OBJECT-TYPE
SYNTAX RsmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsmPortCardShelf, rsmPortCardSlot, rsmPortType }
::= { rsmPortTable 1 }
RsmPortEntry ::=
SEQUENCE
{
rsmPortCardShelf CardShelf,
rsmPortCardSlot SlotInput,
rsmPortType INTEGER,
rsmConnCardType CardType,
rsmConnShelf ShelfInput,
rsmConnSlot SlotInput,
rsmConnPort INTEGER
}
rsmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { rsmPortEntry 1 }
rsmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rsmPortEntry 2 }
rsmPortType OBJECT-TYPE
SYNTAX INTEGER { localARx(1), localATx(2), localBRx(3), localBTx(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the RSM's port. The order is CLI compatible."
::= { rsmPortEntry 3 }
rsmConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Module type connected to rsm port. The valid module types
are OCM10G/OCME/OCMITU/OCMU."
::= { rsmPortEntry 4}
rsmConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2."
::= { rsmPortEntry 5 }
rsmConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to. To delete a
connection associated with a specified port, set this
variable to 0."
::= { rsmPortEntry 6 }
rsmConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Conn port for RSM's port. Only OCM10G/OCME/OCMITU/OCMU
can be connected to RSM. The possible values are:
OCM10G/OCME/OCMITU/OCMU: 3=CPE Tx, 4=CPE Rx"
::= { rsmPortEntry 7 }
-- The elements in the upsm subgroup of the configuration group
upsmBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the rsm
Boot PROM code"
::= { upsm 1 }
upsmROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { upsm 2 }
upsmNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { upsm 3 }
upsmSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { upsm 4 }
upsmSubDivEntry OBJECT-TYPE
SYNTAX UpsmSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { upsmSubDivIndex }
::= { upsmSubDivTable 1 }
UpsmSubDivEntry ::=
SEQUENCE
{
upsmSubDivIndex INTEGER,
upsmSubDivDescr DisplayString,
upsmSubDivSize INTEGER,
upsmSubDivOffset OCTET STRING
}
upsmSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { upsmSubDivEntry 1 }
upsmSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { upsmSubDivEntry 2 }
upsmSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { upsmSubDivEntry 3 }
upsmSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { upsmSubDivEntry 4 }
upsmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of UPSM rows in the following table. This
number is automatically updated whenever a new row is
added to the table below."
::= { upsm 5 }
upsmTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
UPSM card"
::= { upsm 6 }
upsmEntry OBJECT-TYPE
SYNTAX UpsmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { upsmCardLocation, upsmCardShelf, upsmCardSlot }
::= { upsmTable 1 }
UpsmEntry ::=
SEQUENCE
{
upsmCardLocation CardLocation,
upsmCardShelf CardShelf,
upsmCardSlot SlotInput,
upsmModelNum DisplayString,
upsmOpticsMfgDate DateAndTime,
upsmSerialNum SerialString,
upsmModelType INTEGER,
upsmHWName CardName,
upsmCardName CardName,
upsmFWName DisplayString,
upsmFWVersionID VersionString,
upsmFWDate DateAndTime,
upsmSetState RebootType,
upsmRxInsertionLoss DisplayString,
upsmTxInsertionLoss DisplayString,
upsmMarginForSwitch INTEGER,
upsmMinProtPowerForSwitch INTEGER,
upsmDebounce INTEGER,
upsmBlackOutTime INTEGER,
upsmSwitch INTEGER,
upsmLinkAPathID PathIdName,
upsmLinkBPathID PathIdName,
upsmAdminState INTEGER,
upsmCleiNum DisplayString,
upsmSwitchState INTEGER,
upsmNumPorts INTEGER
}
upsmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the UPSM card. Valid values are: Local in
the same chassis."
::= { upsmEntry 1 }
upsmCardShelf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { upsmEntry 2 }
upsmCardSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { upsmEntry 3 }
upsmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UPSM's model number."
::= { upsmEntry 4 }
upsmOpticsMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the optics
on the UPSM card."
::= { upsmEntry 5 }
upsmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the UPSM card."
::= { upsmEntry 6 }
upsmModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the UPSM."
::= { upsmEntry 7 }
upsmHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Manufacturing Hardware name of the UPSM Card."
::= { upsmEntry 8 }
upsmCardName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable card name."
::= { upsmEntry 9 }
upsmFWName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UPSM's Firmware Name."
::= { upsmEntry 10 }
upsmFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the UPSM FW code."
::= { upsmEntry 11 }
upsmFWDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of latest Firmware of the UPSM card."
::= { upsmEntry 12 }
upsmSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the upsm to do a warmboot. A get on this will
always return an other."
::= { upsmEntry 13 }
upsmRxInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Insertion loss for Rx Path."
::= { upsmEntry 14 }
upsmTxInsertionLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Insertion loss for Tx Path."
::= { upsmEntry 15 }
upsmMarginForSwitch OBJECT-TYPE
SYNTAX INTEGER (-32..-6)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The UPSM switching threshold for protection switch to occur.
The limit is from -32 to -6. Switching threshold must be 1 dBm
or more less than the minimum switch power."
::= { upsmEntry 16 }
upsmMinProtPowerForSwitch OBJECT-TYPE
SYNTAX INTEGER (-30..-5)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The minimum protection link power to allow protection switch
to function. The limit is from -30 to -5. This value should
be 1 dBm or more greater than the switch margin."
::= { upsmEntry 17 }
upsmDebounce OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times to measure low power condition
before performing protection switch."
::= { upsmEntry 18 }
upsmBlackOutTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time after protection switch before allowing
another protection switch."
::= { upsmEntry 19 }
upsmSwitch OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
switchToLinkA(2),
switchToLinkB(3),
toggle(4),
enableAutoSwitch(6),
enableSwitchtoLinkA(7),
enableSwitchtoLinkB(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Link switch control. switchToLinkA or
switchToLinkB option would disable auto switch
functionality. Auto switch functionality can
be turned on by setting to enableAutoSwitch
option "
::= { upsmEntry 20 }
upsmLinkAPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsm LinkA Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { upsmEntry 21 }
upsmLinkBPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsm LinkB Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { upsmEntry 22 }
upsmAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that upsm card. Default value is enable.
When disabled, no alarms/events gets
generated."
::= { upsmEntry 23}
upsmCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the upsm Card."
::= { upsmEntry 24 }
upsmSwitchState OBJECT-TYPE
SYNTAX INTEGER { auto(1), forced(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The switching state. Switching state may be
either auto or forced. The auto state means
automatic switching is enabled. Forced state
means swithcing is disabled and has been forced
to the current active link."
::= { upsmEntry 25 }
upsmNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each UPSM card."
::= { upsmEntry 26 }
upsmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
UPSM card's port."
::= { upsm 7 }
upsmPortEntry OBJECT-TYPE
SYNTAX UpsmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { upsmPortCardShelf, upsmPortCardSlot, upsmPortType }
::= { upsmPortTable 1 }
UpsmPortEntry ::=
SEQUENCE
{
upsmPortCardShelf CardShelf,
upsmPortCardSlot SlotInput,
upsmPortType INTEGER,
upsmConnLocation CardLocation,
upsmConnIpAddress IpAddress,
upsmConnChassisID NodeName,
upsmConnSystemName NodeName,
upsmConnCardType INTEGER,
upsmConnPort INTEGER,
upsmConnShelf ShelfInput,
upsmConnSlot SlotInput
}
upsmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2."
::= { upsmPortEntry 1 }
upsmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { upsmPortEntry 2 }
upsmPortType OBJECT-TYPE
SYNTAX INTEGER
{
linkATx(1),
linkARx(2),
linkBTx(3),
linkBRx(4),
localTx(5),
localRx(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of the UPSM's port. The order is CLI compatible."
::= { upsmPortEntry 3 }
upsmConnLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The chassis's location of the card conn to."
::= { upsmPortEntry 4 }
upsmConnIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IpAddress of the connected node. User config. If local
connection, a set on it would return an error; would be automatically
be set to the IP address of the node "
::= { upsmPortEntry 5}
upsmConnChassisID OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Chassis ID of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the chassis Id of the local node"
::= { upsmPortEntry 6}
upsmConnSystemName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"System Name of the connected node. User config. If local connection,
a set on it would return an error; would be automatically be set to
the sysetem name of the local node."
::= { upsmPortEntry 7}
upsmConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Module type connected to upsm port."
::= { upsmPortEntry 8}
upsmConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Conn port for UPSM's port. Possible values based on
card types that can connect to UPSM are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx."
::= { upsmPortEntry 9 }
upsmConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shelf the card conn to. Valid values are: 1 to 2."
::= { upsmPortEntry 10 }
upsmConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card conn to. To delete a
connection associated with a specified port, set this
variable to 0."
::= { upsmPortEntry 11 }
-- The table of mcmesc
mcmescBootPromVer OBJECT-TYPE
SYNTAX VersionString
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current version string of the mcmesc Boot PROM code"
::= { mcmesc 1 }
mcmescROMSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total Size of the ROM in Kilobyes"
::= { mcmesc 2 }
mcmescNumSubDiv OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of the subdivisions of the ROM."
::= { mcmesc 3 }
mcmescSubDivTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the number of sub divisions
and the size of each subdivision in ROM memory"
::= { mcmesc 4 }
mcmescSubDivEntry OBJECT-TYPE
SYNTAX McmescSubDivEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescSubDivIndex }
::= { mcmescSubDivTable 1 }
McmescSubDivEntry ::=
SEQUENCE
{
mcmescSubDivIndex INTEGER,
mcmescSubDivDescr DisplayString,
mcmescSubDivSize INTEGER,
mcmescSubDivOffset OCTET STRING
}
mcmescSubDivIndex OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Integer ID of each sub division in the ROM. The order
of numbering is from the top of the ROM to the bottom
of the ROM."
::= { mcmescSubDivEntry 1 }
mcmescSubDivDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Display Name of each Sub Division in ROM"
::= { mcmescSubDivEntry 2 }
mcmescSubDivSize OBJECT-TYPE
SYNTAX INTEGER (0..1024)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Size of each sub division in ROM in kilobytes"
::= { mcmescSubDivEntry 3 }
mcmescSubDivOffset OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..8))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Starting address of each sub division in the ROM
in HEX notation."
::= { mcmescSubDivEntry 4 }
mcmescNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the following table. This number
is automatically updated whenever a new row is added
to the table below."
::= { mcmesc 5 }
mcmescTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
mcmesc module"
::= { mcmesc 6 }
mcmescEntry OBJECT-TYPE
SYNTAX McmescEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescCardLocation, mcmescCardShelf, mcmescCardSlot }
::= { mcmescTable 1 }
McmescEntry ::=
SEQUENCE
{
mcmescCardLocation CardLocation,
mcmescCardShelf CardShelf,
mcmescCardSlot INTEGER,
mcmescMfgDate DateAndTime,
mcmescSerialNum SerialString,
mcmescModelType INTEGER,
mcmescModelNum DisplayString,
mcmescName CardName,
mcmescHWName CardName,
mcmescNumPorts INTEGER,
mcmescFWVersionID VersionString,
mcmesc2ndFWVersionID VersionString,
mcmescFPGAVersionID VersionString,
mcmesc2ndFPGAVersionID VersionString,
mcmescBoardSerialNum SerialString,
mcmescBoardVersionID VersionString,
mcmescDaughterBoard1SerialNum SerialString,
mcmescDaughterBoard1VersionID VersionString,
mcmescDaughterBoard2SerialNum SerialString,
mcmescDaughterBoard2VersionID VersionString,
mcmescCleiNum DisplayString,
mcmescLinkWavelength DisplayString,
mcmescLinkSfpSerialNum SfpSerialString,
mcmescAdminState INTEGER,
mcmescLinkName LinkName,
mcmescPathID PathIdName,
mcmescOverride Boolean,
mcmescPerfInterval INTEGER,
mcmescCpeRxSigLowThreshold INTEGER,
mcmescLinkRxSigLowThreshold INTEGER,
mcmescCpeErrEventThreshold INTEGER,
mcmescCpeErrAlarmThreshold INTEGER,
mcmescLinkErrEventThreshold INTEGER,
mcmescLinkErrAlarmThreshold INTEGER,
mcmescTestSequence FlagType,
mcmescConnMuxShelf ShelfInput,
mcmescConnMuxSlot SlotInput,
mcmescConnMuxPort INTEGER,
mcmescConnDemuxShelf ShelfInput,
mcmescConnDemuxSlot SlotInput,
mcmescConnDemuxPort INTEGER,
mcmescConnTxOcmShelf ShelfInput,
mcmescConnTxOcmSlot SlotInput,
mcmescConnTxOcmPort INTEGER,
mcmescConnTxOcmShelfSlot DisplayString,
mcmescConnTxOcmDelete Boolean,
mcmescConnRxOcmShelf ShelfInput,
mcmescConnRxOcmSlot SlotInput,
mcmescConnRxOcmPort INTEGER,
mcmescConnRxOcmShelfSlot DisplayString,
mcmescConnRxOcmDelete Boolean,
mcmescSetState INTEGER,
mcmescLinkClrErrCount INTEGER
}
mcmescCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the mcmesc Module."
::= { mcmescEntry 1 }
mcmescCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the mcmesc is in. Valid values are: 1..2"
::= { mcmescEntry 2 }
mcmescCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { mcmescEntry 3 }
mcmescMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of calibration of the mcmesc card"
::= { mcmescEntry 4 }
mcmescSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the mcmesc card."
::= { mcmescEntry 5 }
mcmescModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the mcmesc"
::= { mcmescEntry 6 }
mcmescModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model number of the MCMESC card. Up to 15 characters"
::= { mcmescEntry 7 }
mcmescName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Display (Network) name of the MCMESC Module"
::= { mcmescEntry 8 }
mcmescHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Hardware name of the MCMESC Card."
::= { mcmescEntry 9 }
mcmescNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers of MCM module."
::= { mcmescEntry 10 }
mcmescFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the MCMESC FW code"
::= { mcmescEntry 11 }
mcmesc2ndFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version string of the MCMESC second FW code"
::= { mcmescEntry 12 }
mcmescFPGAVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the MCMESC FPGA code"
::= { mcmescEntry 13 }
mcmesc2ndFPGAVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version string of the MCMESC second FPGA code"
::= { mcmescEntry 14 }
mcmescBoardSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the MCMESC board."
::= { mcmescEntry 15 }
mcmescBoardVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version string of the MCMESC board"
::= { mcmescEntry 16 }
mcmescDaughterBoard1SerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the MCMESC daughter board 1."
::= { mcmescEntry 17 }
mcmescDaughterBoard1VersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version string of the MCMESC daughter board 1"
::= { mcmescEntry 18 }
mcmescDaughterBoard2SerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial # of the MCMESC daughter board 2."
::= { mcmescEntry 19 }
mcmescDaughterBoard2VersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version string of the MCMESC daughter board 2"
::= { mcmescEntry 20 }
mcmescCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the MCMESC Card."
::= { mcmescEntry 21 }
mcmescLinkWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link Wavelength of the MCMESC card"
::= { mcmescEntry 22 }
mcmescLinkSfpSerialNum OBJECT-TYPE
SYNTAX SfpSerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link port's SFP serial number."
::= { mcmescEntry 23 }
mcmescAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that MCMESC card. Default value is enable.
When disabled, no alarms/events gets generated."
::= { mcmescEntry 24 }
mcmescLinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link name for fiber between the local and the
remote MCMESC card."
::= { mcmescEntry 25 }
mcmescPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { mcmescEntry 26 }
mcmescOverride OBJECT-TYPE
SYNTAX INTEGER { yes(1), no(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MPM overrides the settings stored on MCMESC card upon
detecting it. Default value is no. Not applicable to
remote MCMESC."
::= { mcmescEntry 27 }
mcmescPerfInterval OBJECT-TYPE
SYNTAX INTEGER (60..3600)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interval, in seconds, in which MCMESC collects the
performance data, ranging 60 to 3600."
::= { mcmescEntry 28 }
mcmescCpeRxSigLowThreshold OBJECT-TYPE
SYNTAX INTEGER (-29..-7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of reporting CPE port Rx signal low alarm,
in dBm, ranging from -29 to -7."
::= { mcmescEntry 29 }
mcmescLinkRxSigLowThreshold OBJECT-TYPE
SYNTAX INTEGER (-29..-7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of reporting Link Rx signal low alarm,
in dBm, ranging from -29 to -7."
::= { mcmescEntry 30 }
mcmescCpeErrEventThreshold OBJECT-TYPE
SYNTAX INTEGER (5..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of reporting CPE error event, in the form of
1.0E-x. Only x needs to be set and will be read. The range
of x is from 5 to 15, however, input should be an
absolute value if using mib browser. This threshold should
be lower than the value of
mcmescCpeErrAlarmThreshold, i.e., the absolute value
should be higher than of mcmescCpeErrAlarmThreshold."
::= { mcmescEntry 31 }
mcmescCpeErrAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER (4..14)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of reporting CPE error alarm, in the form of
1.0E-x. The range of x is from 4 to 14, however, input
should be an absolute value if using mib browser. This
threshold should be higher than the value of
mcmescCpeErrEventThreshold, i.e., the absolute value
should be lower than of mcmescCpeErrEventThreshold."
::= { mcmescEntry 32 }
mcmescLinkErrEventThreshold OBJECT-TYPE
SYNTAX INTEGER (5..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of reporting LINK error event, in the form of
1.0E-x. The range of x is from 5 to 15, however, input
should be an absolute value if using mib browser. This
threshold should be lower than the value of
mcmescLinkErrAlarmThreshold, i.e., the absolute value
should be higher than of mcmescLinkErrAlarmThreshold."
::= { mcmescEntry 33 }
mcmescLinkErrAlarmThreshold OBJECT-TYPE
SYNTAX INTEGER (4..14)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The threshold of reporting LINK error alarm, in the form of
1.0E-x. The range of x is from 4 to 14, however, input
should be an absolute value if using mib browser. This
threshold should be higher than the value of
mcmescLinkErrEventThreshold, i.e., the absolute value
should be lower than of mcmescLinkErrEventThreshold."
::= { mcmescEntry 34 }
mcmescTestSequence OBJECT-TYPE
SYNTAX FlagType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turn on or off the test-sequence on link. The operation
will take place on the remote MCMESC if it's connected."
::= { mcmescEntry 35 }
mcmescConnMuxShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected W4CM/UPSM shelf."
::= { mcmescEntry 36 }
mcmescConnMuxSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected W4CM/UPSM slot."
::= { mcmescEntry 37 }
mcmescConnMuxPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected W4CM/UPSM port.
W4CM: 1=1470/1510, 2=1490/1530, 3=15501590/,
4=1570/1610, 5=EXP, 6=IN/OUT;
UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx."
::= { mcmescEntry 38 }
mcmescConnDemuxShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected W4CD/UPSM shelf."
::= { mcmescEntry 39 }
mcmescConnDemuxSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected W4CD/UPSM slot."
::= { mcmescEntry 40 }
mcmescConnDemuxPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected W4CD/UPSM port.
W4CD: 1=1470/1510, 2=1490/1530, 3=15501590/,
4=1570/1610, 5=EXP, 6=IN/OUT;
UPSM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx."
::= { mcmescEntry 41 }
mcmescConnTxOcmShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected OCM shelf (from MCMESC's Link Tx)."
::= { mcmescEntry 42 }
mcmescConnTxOcmSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected OCM slot (from MCMESC's Link Tx)."
::= { mcmescEntry 43 }
mcmescConnTxOcmPort OBJECT-TYPE
SYNTAX INTEGER { cpetx(3), cperx(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected OCM port (from MCMESC's Link Tx).
3=OCM's CPE-Tx, 4=OCM's Rx. Only 4 is valid."
::= { mcmescEntry 44 }
mcmescConnTxOcmShelfSlot OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add a connection from MCMESC Link-Tx to an OCM CPE-Rx by
specifying the OCM's shelf and slot. The format is shlef,slot.
If either MCMESC Link-Tx or specified OCM CPE-Rx has already
had connection, an error will be returned. If the card
specified by shelf,slot is not ocm type, an error will
be returned.
A get on this variable will always return 0,0."
::= { mcmescEntry 45 }
mcmescConnTxOcmDelete OBJECT-TYPE
SYNTAX INTEGER { other(1), yes(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete a connection from MCMESC Link-Tx to an OCM CPE-Rx.
If MCMESC's Link-Tx has no connection with any OCM's CPE-Rx,
an error will be returned.
A get on this variable will always return an other."
::= { mcmescEntry 46 }
mcmescConnRxOcmShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The connected OCM shelf (from MCMESC's Link Rx)."
::= { mcmescEntry 47 }
mcmescConnRxOcmSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The connected OCM slot (from MCMESC's Link Rx)."
::= { mcmescEntry 48 }
mcmescConnRxOcmPort OBJECT-TYPE
SYNTAX INTEGER { cpetx(3), cperx(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The connected OCM port (from MCMESC's Link Rx).
3=OCM's CPE-Tx, 4=OCM's Rx. Only 3 is valid."
::= { mcmescEntry 49 }
mcmescConnRxOcmShelfSlot OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add a connection from MCMESC Link-Rx to an OCM CPE-Tx by
specifying the OCM's shelf and slot. The format is shlef,slot.
If either MCMESC Link-Tx or specified OCM CPE-Rx has already
had connection, an error will be returned. If the card
specified by shelf,slot is not ocm type, an error will
be returned.
A get on this variable will always return 0,0"
::= { mcmescEntry 50 }
mcmescConnRxOcmDelete OBJECT-TYPE
SYNTAX INTEGER { other(1), yes(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete a connection from MCMESC Link-Rx to an OCM CPE-Tx.
If MCMESC's Link-Rx has no connection with any OCM's CPE-Tx,
an error will be returned.
A get on this variable will always return an other."
::= { mcmescEntry 51 }
mcmescSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
resetWithCurrentConfiguration(2),
nearEndCardLoopback(3),
networkCardLoopback(4),
nearEndPort1Loopback(5),
nearEndPort2Loopback(6),
nearEndPort3Loopback(7),
nearEndPort4Loopback(8),
nearEndPort5Loopback(9),
nearEndPort6Loopback(10),
nearEndPort7Loopback(11),
nearEndPort8Loopback(12),
nearEndPort9Loopback(13),
nearEndPort10Loopback(14),
nearEndPort11Loopback(15),
nearEndPort12Loopback(16),
networkPort1Loopback(17),
networkPort2Loopback(18),
networkPort3Loopback(19),
networkPort4Loopback(20),
networkPort5Loopback(21),
networkPort6Loopback(22),
networkPort7Loopback(23),
networkPort8Loopback(24),
networkPort9Loopback(25),
networkPort10Loopback(26),
networkPort11Loopback(27),
networkPort12Loopback(28),
disableLoopback(29)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the mcmesc card to do either a reset or loopback.
A get on this will always return an other. If the card is
in self-test, an error will be returned. If the card is
already in any loopback, and try to turn on another loopback,
an error will be returned."
::= { mcmescEntry 52 }
mcmescLinkClrErrCount OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
clearErrCount(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the mcmesc card to clear the bit-error count for
link port. A get on this will always return an other."
::= { mcmescEntry 53}
mcmescPortNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of MCMESC rows in the following table. This
number is automatically updated whenever a new row is
added to the table below."
::= { mcmesc 7 }
mcmescPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
MCMESC module's port."
::= { mcmesc 8 }
mcmescPortEntry OBJECT-TYPE
SYNTAX McmescPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescPortCardLocation, mcmescPortCardShelf,
mcmescPortCardSlot, mcmescPortIndex }
::= { mcmescPortTable 1 }
McmescPortEntry ::=
SEQUENCE
{
mcmescPortCardLocation CardLocation,
mcmescPortCardShelf CardShelf,
mcmescPortCardSlot INTEGER,
mcmescPortIndex INTEGER,
mcmescPortSfpSerialNum SfpSerialString,
mcmescPortConnectionState INTEGER,
mcmescPortClrErrCount INTEGER
}
mcmescPortCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the MCMESC port. Valid values are: Local in
the same chassis, or remote to this chassis."
::= { mcmescPortEntry 1 }
mcmescPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1..2."
::= { mcmescPortEntry 2 }
mcmescPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the Module is in. Valid
values are: 1 to 17."
::= { mcmescPortEntry 3 }
mcmescPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE port's index. Valid values are: 1 to 12."
::= { mcmescPortEntry 4 }
mcmescPortSfpSerialNum OBJECT-TYPE
SYNTAX SfpSerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE port's SFP serial number."
::= { mcmescPortEntry 5 }
mcmescPortConnectionState OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CPE port's connection status."
::= { mcmescPortEntry 6 }
mcmescPortClrErrCount OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
clearErrCount(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the mcmesc card to clear the bit-error count for
a CPE port. A get on this will always return an other."
::= { mcmescPortEntry 7}
-- The elements in the topology subgroup of the configuration group
topologyTable OBJECT-TYPE
SYNTAX SEQUENCE OF TopologyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the link topology between local and
remote cards"
::= { topology 1}
topologyEntry OBJECT-TYPE
SYNTAX TopologyEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { topologyNearEndCardShelf, topologyNearEndCardSlot,
topologyNearEndCardPortIndex, topologyFarEndNodeCardShelf,
topologyFarEndNodeCardSlot, topologyFarEndNodeCardPortIndex }
::= { topologyTable 1 }
TopologyEntry ::=
SEQUENCE
{
topologyNearEndCardShelf CardShelf,
topologyNearEndCardSlot INTEGER,
topologyNearEndCardPortIndex PortIndex,
topologyNearEndCardType CardType,
topologyFarEndChassisID NodeName,
topologyFarEndSystemName NodeName,
topologyFarEndNodeIpAddress IpAddress,
topologyFarEndNodeCardShelf CardShelf,
topologyFarEndNodeCardSlot INTEGER,
topologyFarEndNodeCardPortIndex PortIndex,
topologyLinkStatus INTEGER,
topologyFarEndNodeCardType CardType
}
topologyNearEndCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Shelf of the near end card."
::= { topologyEntry 1 }
topologyNearEndCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Slot of the near end card. Input 0 will
delete the topology link."
::= { topologyEntry 2 }
topologyNearEndCardPortIndex OBJECT-TYPE
SYNTAX PortIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Near end optical link port."
::= { topologyEntry 3 }
topologyNearEndCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Card type of the near end card."
::= { topologyEntry 4 }
topologyFarEndChassisID OBJECT-TYPE
SYNTAX NodeName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Chassis ID of the far end chassis. Part of manufacturing info"
::= { topologyEntry 5}
topologyFarEndSystemName OBJECT-TYPE
SYNTAX NodeName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Name of the far end node/chassis. Not supported for
remote TMM masters."
::= { topologyEntry 6}
topologyFarEndNodeIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IpAddress of the far end chassis. Not supported for
remote TMM masters."
::= { topologyEntry 7}
topologyFarEndNodeCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Shelf of the far end module"
::= { topologyEntry 8}
topologyFarEndNodeCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot of the far end module"
::= { topologyEntry 9}
topologyFarEndNodeCardPortIndex OBJECT-TYPE
SYNTAX PortIndex
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Far end optical link port."
::= { topologyEntry 10}
topologyLinkStatus OBJECT-TYPE
SYNTAX INTEGER { down(1), active(2), standby(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of the link to indicate if active or down"
::= { topologyEntry 11}
topologyFarEndNodeCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Card type of the far end card."
::= { topologyEntry 12 }
topologyDiscover OBJECT-TYPE
SYNTAX INTEGER { other(1), discoverTopology(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An action to rediscover the complete topology
A get would alway return other(1)."
::= { topology 2 }
-- The elements in the routing subgroup of the configuration group
-- This table is no longer supported, instead user needs to use imnRoutingTable
routingTable OBJECT-TYPE
SYNTAX SEQUENCE OF RoutingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents dynamic and static routing information"
::= { routing 1}
routingEntry OBJECT-TYPE
SYNTAX RoutingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { routeIpDestAddress, routeLocalCCShelf, routeLocalCCSlot }
::= { routingTable 1 }
RoutingEntry ::=
SEQUENCE
{
routeLocalCCShelf CardShelf,
routeLocalCCSlot INTEGER,
routeIpDestAddress IpAddress,
routeDestType INTEGER,
routeMode INTEGER
}
routeLocalCCShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Shelf of the local CC card."
::= { routingEntry 1 }
routeLocalCCSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Slot of the local CC card."
::= { routingEntry 2 }
routeIpDestAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Destination IP address. Not supported for
remote TMM masters."
::= { routingEntry 3}
routeDestType OBJECT-TYPE
SYNTAX INTEGER { externalRoute(1), internalRoute(2) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Destination route type. External means destination is not part of LuxN network.
Internal means destination is one of the LuxN node "
::= { routingEntry 4 }
routeMode OBJECT-TYPE
SYNTAX INTEGER { static(1), dynamic(2) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Is the route added statically(manually) or dynamically(automatic) "
::= { routingEntry 5 }
imnDynamicRoutingTable OBJECT-TYPE
SYNTAX SEQUENCE OF ImnDynamicRoutingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents IMN based dynamic routing information"
::= { routing 2}
imnDynamicRoutingEntry OBJECT-TYPE
SYNTAX ImnDynamicRoutingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { imnDynamicRouteIpDest}
::= { imnDynamicRoutingTable 1 }
ImnDynamicRoutingEntry ::=
SEQUENCE
{
imnDynamicRouteIpDest IpAddress,
imnDynamicRouteIpMask IpAddress,
imnDynamicRouteMetric INTEGER,
imnDynamicRouteNextHop IpAddress,
imnDynamicRouteSysName DisplayString
}
imnDynamicRouteIpDest OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination IP address. Not supported for
remote TMM masters."
::= { imnDynamicRoutingEntry 1}
imnDynamicRouteIpMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination's IP mask address. Not supported for
remote TMM masters."
::= { imnDynamicRoutingEntry 2}
imnDynamicRouteMetric OBJECT-TYPE
SYNTAX INTEGER(1..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Cost associated with this route."
::= { imnDynamicRoutingEntry 3}
imnDynamicRouteNextHop OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Neighbour node of this route."
::= { imnDynamicRoutingEntry 4}
imnDynamicRouteSysName OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination system name associated with route."
::= { imnDynamicRoutingEntry 5}
imnRouteUpdateTimer OBJECT-TYPE
SYNTAX INTEGER (1..254)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time in seconds for the route table to get updated/propagated
Default value is 30 seconds."
::= { routing 3}
imnRouteKeepAliveTimer OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time in seconds before neighbors enter unreachable state after communication
is lost. This value has to be greater than or equal to imnRouteUpdateTimer
Default value is 60 seconds"
::= { routing 4}
imnRouteUnReachableTimer OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time in seconds before Neighbors in unreachable state are deleted from
the route table. This value has to greater than or equal to imnRouteUpdateTimer
Default value is 60 seconds"
::= { routing 5}
imnRouteMode OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable IMN functionality. Default is disabled"
::= { routing 6}
imnStaticRoutingTable OBJECT-TYPE
SYNTAX SEQUENCE OF ImnStaticRoutingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents IMN based static routing information"
::= { routing 7}
imnStaticRoutingEntry OBJECT-TYPE
SYNTAX ImnStaticRoutingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { imnStaticRouteIpDest}
::= { imnStaticRoutingTable 1 }
ImnStaticRoutingEntry ::=
SEQUENCE
{
imnStaticRouteIpDest IpAddress,
imnStaticRouteIpMask IpAddress,
imnStaticRouteMetric INTEGER
}
imnStaticRouteIpDest OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination IP address. Not supported for
remote TMM masters."
::= { imnStaticRoutingEntry 1}
imnStaticRouteIpMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination's IP mask address. Not supported for
remote TMM masters."
::= { imnStaticRoutingEntry 2}
imnStaticRouteMetric OBJECT-TYPE
SYNTAX INTEGER(1..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Cost associated with this route."
::= { imnStaticRoutingEntry 3}
imnRouteMaxMetric OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum acceptable metric count before the routes gets dropped.
Default value is 255. Ideally this value should be greater than
imnStaticRouteMetric"
::= { routing 8}
-- The elements in the ring subgroup of the configuration group
ringNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of ring configured in the list."
::= { ring 1 }
ringTable OBJECT-TYPE
SYNTAX SEQUENCE OF RingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represent the ring information"
::= { ring 2}
ringEntry OBJECT-TYPE
SYNTAX RingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ringIndex }
::= { ringTable 1 }
RingEntry ::=
SEQUENCE
{
ringIndex INTEGER,
ringID RingIdName,
ringPathID1 PathIdName,
ringPathID2 PathIdName,
ringPath1RemoteIP IpAddress,
ringPath1RemoteChassisId DisplayString,
ringPath2RemoteIP IpAddress,
ringPath2RemoteChassisId DisplayString
}
ringIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The ringIndex and also the index of the ring table."
::= { ringEntry 1 }
ringID OBJECT-TYPE
SYNTAX RingIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RingID Name for UPSR. Empty string will remove and deassociate
the RingID with the PathIDs. You always has one dummy entry for
adding another ring."
::= { ringEntry 2 }
ringPathID1 OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"PathID 1 associate with this ring."
::= { ringEntry 3}
ringPathID2 OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"PathID 2 associate with this ring."
::= { ringEntry 4}
ringPath1RemoteIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Address of the neighbor node associated with path 1"
::= { ringEntry 5 }
ringPath1RemoteChassisId OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Chassis ID of the neighbor node associated with path 1"
::= { ringEntry 6}
ringPath2RemoteIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IP Address of the neighbor node associated with path 2"
::= { ringEntry 7 }
ringPath2RemoteChassisId OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Chassis ID of the neighbor node associated with path 2"
::= { ringEntry 8}
-- The elements in the tap subgroup of the configuration group
tapNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of TAP rows in the following table. This number
is automatically updated whenever a new row is added
to the table below."
::= { tap 1 }
tapTable OBJECT-TYPE
SYNTAX SEQUENCE OF TapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
TAP module"
::= { tap 2 }
tapEntry OBJECT-TYPE
SYNTAX TapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { tapCardLocation, tapCardShelf, tapCardSlot }
::= { tapTable 1 }
TapEntry ::=
SEQUENCE
{
tapCardLocation CardLocation,
tapCardShelf CardShelf,
tapCardSlot INTEGER,
tapModelNum DisplayString,
tapMfgDate DateAndTime,
tapSerialNum SerialString,
tapModelType INTEGER,
tapName CardName,
tapFWVersionID VersionString,
tapHWName CardName,
tapPathID PathIdName,
tapAdminState INTEGER,
tapCleiNum DisplayString,
tapNumPorts INTEGER
}
tapCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { tapEntry 1 }
tapCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { tapEntry 2 }
tapCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in. The range
of valid values range from 1 through 17 depending on
the chassis type and the shelf the module is in.
To delete this card, set this variable to 0."
::= { tapEntry 3 }
tapModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model number for module."
::= { tapEntry 4 }
tapMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { tapEntry 5 }
tapSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Serial number of the module."
::= { tapEntry 6 }
tapModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module"
::= { tapEntry 7 }
tapName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module"
::= { tapEntry 8 }
tapFWVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current version string of the FW code"
::= { tapEntry 9 }
tapHWName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Display Hardware name of the module."
::= { tapEntry 10 }
tapPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upsr Path ID name that this card is associated with.
Set input equal NULL will remove the card off the path
and also remove the path if there is no card left
associate with that path."
::= { tapEntry 11 }
tapAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control over that TAP card. Default value is enable.
When disabled, no alarms/events gets generated."
::= { tapEntry 12 }
tapCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number for the module."
::= { tapEntry 13 }
tapNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each TAP card."
::= { tapEntry 14 }
-- The elements in the voadm subgroup of the configuration group
voadmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the voadm table. This number
is automatically updated whenever a new row is added
to the table below."
::= { voadm 1 }
voadmTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoadmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
VOADM card"
::= { voadm 2 }
voadmEntry OBJECT-TYPE
SYNTAX VoadmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { voadmCardLocation, voadmCardShelf, voadmCardSlot }
::= { voadmTable 1 }
VoadmEntry ::=
SEQUENCE
{
voadmCardLocation CardLocation,
voadmCardShelf CardShelf,
voadmCardSlot INTEGER,
voadmSerialNum SerialString,
voadmModelNum DisplayString,
voadmHwName DisplayString,
voadmHwVersionID VersionString,
voadmMfgDate DateAndTime,
voadmFwName CardName,
voadmFwVersionID VersionString,
voadmFwDate DateAndTime,
voadmAdminState INTEGER,
voadmModelType INTEGER,
voadmName CardName,
voadmSetState RebootType,
voadmPathID PathIdName,
voadmCleiNum DisplayString,
voadmActiveChannels INTEGER,
voadmStartItu INTEGER,
voadmEndItu INTEGER,
voadmNumPorts INTEGER
}
voadmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module. VOADM modules will
always be seen as local modules."
::= { voadmEntry 1 }
voadmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { voadmEntry 2 }
voadmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { voadmEntry 3 }
voadmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { voadmEntry 4 }
voadmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { voadmEntry 5 }
voadmHwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { voadmEntry 6 }
voadmHwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { voadmEntry 7 }
voadmMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { voadmEntry 8 }
voadmFwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { voadmEntry 9 }
voadmFwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { voadmEntry 10 }
voadmFwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { voadmEntry 11 }
voadmAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { voadmEntry 12}
voadmModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { voadmEntry 13 }
voadmName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { voadmEntry 14 }
voadmSetState OBJECT-TYPE
SYNTAX RebootType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot. A get on this will
always return 'other'."
::= { voadmEntry 15 }
voadmPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that path."
::= { voadmEntry 16 }
voadmCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the module."
::= { voadmEntry 17 }
voadmActiveChannels OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of active channels connected to the module.
The allowed inpu range depends on the module type:
MD100-5 1 to 5
MD100-10 1 to 10"
::= { voadmEntry 18 }
voadmStartItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"First ITU channel supported by the module."
::= { voadmEntry 19 }
voadmEndItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Last ITU channel supported by the module."
::= { voadmEntry 20 }
voadmNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each VOADM card."
::= { voadmEntry 21 }
voadmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoadmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { voadm 3 }
voadmPortEntry OBJECT-TYPE
SYNTAX VoadmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { voadmPortCardLocation, voadmPortCardShelf, voadmPortCardSlot, voadmPortType }
::= { voadmPortTable 1 }
VoadmPortEntry ::=
SEQUENCE
{
voadmPortCardLocation CardLocation,
voadmPortCardShelf CardShelf,
voadmPortCardSlot SlotInput,
voadmPortType INTEGER,
voadmPortMode INTEGER,
voadmPortSetPoint DisplayString,
voadmPortMinChanInputPower DisplayString,
voadmPortMinChanOutputPower DisplayString,
voadmPortMaxChanOutputPower DisplayString,
voadmPortToleranceUpperBound DisplayString,
voadmPortToleranceLowerBound DisplayString,
voadmPortTotalInputPower DisplayString,
voadmPortPerChanInputPower DisplayString,
voadmPortTotalOutputPower DisplayString,
voadmPortPerChanOutputPower DisplayString,
voadmPortMeasuredAtten DisplayString,
voadmPortAvgInsertLoss DisplayString,
voadmPortAvgExpressLoss DisplayString
}
voadmPortCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module. VOADM modules will
always be seen as local modules."
::= { voadmPortEntry 1 }
voadmPortCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { voadmPortEntry 2 }
voadmPortCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { voadmPortEntry 3 }
voadmPortType OBJECT-TYPE
SYNTAX INTEGER { mux(1), demux(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port type for which the below values apply."
::= { voadmPortEntry 4 }
voadmPortMode OBJECT-TYPE
SYNTAX INTEGER { fixed-attentuation(1), fixed-power(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port mode. This value will not be stored in the
database until the port set point is set."
::= { voadmPortEntry 5 }
voadmPortSetPoint OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port set point. Valid range depends on the port mode:
Fixed Attentuation 0.0 to 20.0 (dB)
Fixed Power -30.0 to 15.0 (dBm)
Untils are omitted when setting."
::= { voadmPortEntry 6 }
voadmPortMinChanInputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum input power for each active channel. Valid range
for Mux and Demux ports is -30.0 to 15.0 dBm"
::= { voadmPortEntry 7 }
voadmPortMinChanOutputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Minimum output power for each active channel. Valid range
depends on port:
Mux -20.0 to 15.0 dBm
Demux -30.0 to -8.0 dBm."
::= { voadmPortEntry 8 }
voadmPortMaxChanOutputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum output power for each active channel. Valid range
depends on port:
Mux -20.0 to 15.0 dBm
Demux -30.0 to -8.0 dBm."
::= { voadmPortEntry 9 }
voadmPortToleranceUpperBound OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Upper bound for allowable power/attenuation error.
Valid range is 0.2 to 10.0 dB."
::= { voadmPortEntry 10}
voadmPortToleranceLowerBound OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lower bound for allowable power/attenuation error.
Valid range is 0.2 to 10.0 dB."
::= { voadmPortEntry 11 }
voadmPortTotalInputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power reading from input detector. Valid range:
-30 to 15 dBm"
::= { voadmPortEntry 12 }
voadmPortPerChanInputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total input power divided by number of active
channels. Valid range:
-30 to 15 dBm"
::= { voadmPortEntry 13 }
voadmPortTotalOutputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Power reading from output detector. Valid range:
-30 to 15 dBm"
::= { voadmPortEntry 14 }
voadmPortPerChanOutputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total output power divided by number of active
channels. Valid range:
-30 to 15 dBm"
::= { voadmPortEntry 15 }
voadmPortMeasuredAtten OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Difference between total input power and total
output power."
::= { voadmPortEntry 16 }
voadmPortAvgInsertLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average insertion loss for ports."
::= { voadmPortEntry 17 }
voadmPortAvgExpressLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Average express los for ports."
::= { voadmPortEntry 18 }
-- ZMS config synchronization elements
zmsConfigSyncExists OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether or not there exists records to be
sent to the ZMS config synch manager for changes
that have been made by CLI/HTTP to the data base."
::= { zmsConfigSync 1 }
zmsConfigSyncOverflow OBJECT-TYPE
SYNTAX Boolean
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether or not the device had to discard
update data base records due to resource constraints.
If TRUE, traps will be sent to the ZMS Config Synch
Manager indicating a download of the entire data
base is required."
::= { zmsConfigSync 2 }
zmsConfigSyncPriority OBJECT-TYPE
SYNTAX INTEGER
{
none(1),
low(2),
medium(3),
high(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the highest priority configuration synchronization trap
outstanding. This flag is set to none at boot time and whenever a file
of synchronization changes has been sent to ZMS. If a parameter change
has been made to either the same or lower prioirty, the device does
not have to send a change notification to ZMS. Higher priority
fields must immediately cause traps to be sent to ZMS."
::= { zmsConfigSync 3 }
zmsConfigSyncAction OBJECT-TYPE
SYNTAX INTEGER
{
noAction(1),
createList(2),
createFullList(3),
createFullListWithAlarms(4),
createAlarmsList(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used by ZMS when it wants to create a list
of config synch records. It must first write the
filename expected and then set the action. The
create list action allows the device to determine
whether the complete database (synchoverflow
occured) needs to be sent or only those records
that have been modified. create full list
specifies that ZMS would like to receive the
complete database."
::= { zmsConfigSync 4 }
zmsConfigSyncFileName OBJECT-TYPE
SYNTAX ZmsFileName
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"File Name to be used when creating the config
synch records."
::= { zmsConfigSync 5 }
zmsConfigSyncStatus OBJECT-TYPE
SYNTAX INTEGER
{
syncComplete(1),
syncPending(2),
syncError(3),
syncInitializing(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Used by Config Sync Acgent when processing a request
to create a list of config synch records."
::= { zmsConfigSync 6 }
zmsConfigSyncUserName OBJECT-TYPE
SYNTAX ZmsAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"User Name to be used when sending the config
synch records.
When read, the last user name is returned. "
::= { zmsConfigSync 7 }
zmsConfigSyncUserPassword OBJECT-TYPE
SYNTAX ZmsAdminString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Password to be used when sending the config
synch records. For use in FTP authentication.
When read, always returns the NULL string"
::= { zmsConfigSync 8 }
zmsIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the ZMS IP address for which configuration synchronization
messages and any other special handling is performed."
::= { zmsConfigSync 9 }
-- The elements in the dmm subgroup of the configuration group
dmmNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the dmm table. This number
is automatically updated whenever a new row is added
to the table below."
::= { dmm 1 }
dmmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
DMM card"
::= { dmm 2 }
dmmEntry OBJECT-TYPE
SYNTAX DmmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dmmCardLocation, dmmCardShelf, dmmCardSlot }
::= { dmmTable 1 }
DmmEntry ::=
SEQUENCE
{
dmmCardLocation CardLocation,
dmmCardShelf CardShelf,
dmmCardSlot INTEGER,
dmmSerialNum SerialString,
dmmModelNum DisplayString,
dmmHwName DisplayString,
dmmHwVersionID VersionString,
dmmMfgDate DateAndTime,
dmmFwName CardName,
dmmFwVersionID VersionString,
dmmFwDate DateAndTime,
dmmAdminState INTEGER,
dmmModelType INTEGER,
dmmName CardName,
dmmSetState INTEGER,
dmmPathID PathIdName,
dmmLinkName LinkName,
dmmCleiNum DisplayString,
dmmNumPorts INTEGER,
dmmFpgaRev INTEGER
}
dmmCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { dmmEntry 1 }
dmmCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { dmmEntry 2 }
dmmCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { dmmEntry 3 }
dmmSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { dmmEntry 4 }
dmmModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { dmmEntry 5 }
dmmHwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { dmmEntry 6 }
dmmHwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { dmmEntry 7 }
dmmMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { dmmEntry 8 }
dmmFwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { dmmEntry 9 }
dmmFwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { dmmEntry 10 }
dmmFwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { dmmEntry 11 }
dmmAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { dmmEntry 12}
dmmModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { dmmEntry 13 }
dmmName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { dmmEntry 14 }
dmmSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2),
enableLinkLoopback(3),
enablePort1Loopback(4),
enablePort2Loopback(5),
disableloopback(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot. A get on this will
always return 'other'."
::= { dmmEntry 15 }
dmmPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that path."
::= { dmmEntry 16 }
dmmLinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link name for fiber between the local and the
remote card."
::= { dmmEntry 17 }
dmmCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the module."
::= { dmmEntry 18 }
dmmNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each DMM card."
::= { dmmEntry 19 }
dmmFpgaRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA revision for the module."
::= { dmmEntry 20 }
dmmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { dmm 3 }
dmmPortEntry OBJECT-TYPE
SYNTAX DmmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dmmPortLocation, dmmPortShelf, dmmPortSlot, dmmPortIndex }
::= { dmmPortTable 1 }
DmmPortEntry ::=
SEQUENCE
{
dmmPortLocation CardLocation,
dmmPortShelf CardShelf,
dmmPortSlot SlotInput,
dmmPortIndex INTEGER,
dmmPortLineRate INTEGER,
dmmPortAutoDisable INTEGER,
dmmPortMode INTEGER,
dmmPortItu INTEGER,
dmmPortWavelength DisplayString,
dmmPortRxPower DisplayString,
dmmPortTxState INTEGER,
dmmPortTxReach INTEGER,
dmmPortSfpSerialNumber DisplayString,
dmmPortSfpConnectorType INTEGER
}
dmmPortLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { dmmPortEntry 1 }
dmmPortShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { dmmPortEntry 2 }
dmmPortSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { dmmPortEntry 3 }
dmmPortIndex OBJECT-TYPE
SYNTAX INTEGER { link(1), port1(2), port2(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { dmmPortEntry 4 }
dmmPortLineRate OBJECT-TYPE
SYNTAX INTEGER
{
notapplicable(0),
gbEthernet(4),
fibreChannel(5),
disabled(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port line rate. Valid only for ports 1 and 2."
::= { dmmPortEntry 5 }
dmmPortAutoDisable OBJECT-TYPE
SYNTAX INTEGER { notapplicable(0), enable(1), disable(2), farEndEnable(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable the CPE link when a fault
is detected. Far end CPE disable is identical to normal
CPE disable with the added feature that the local
CPE Tx will be disabled if a loss of light condition
is detected on the remote CPE Rx."
::= { dmmPortEntry 6 }
dmmPortMode OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enabled(2), loopback(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port mode."
::= { dmmPortEntry 7 }
dmmPortItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port ITU number. The ITU number is determined
from the SFP wavelength."
::= { dmmPortEntry 8 }
dmmPortWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wavelength from port SFP."
::= { dmmPortEntry 9 }
dmmPortRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive power reported by port SFP."
::= { dmmPortEntry 10}
dmmPortTxState OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of port SFP transmitter."
::= { dmmPortEntry 11 }
dmmPortTxReach OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical reach in meters reported by port SFP."
::= { dmmPortEntry 12 }
dmmPortSfpSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port SFP serial number."
::= { dmmPortEntry 13 }
dmmPortSfpConnectorType OBJECT-TYPE
SYNTAX INTEGER
{
na(0),
unknown(1),
sc(2),
fc_copper1(3),
fc_capper2(4),
bnc(5),
fc_coaxial(6),
fiberjack(7),
lc(8),
mtrj(9),
mu(10),
sg(11),
optpigtail(12),
hssdcii(33),
copper(34)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port SFP connector type."
::= { dmmPortEntry 14 }
dmmConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { dmm 4 }
dmmConnEntry OBJECT-TYPE
SYNTAX DmmConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dmmConnCardLocation, dmmConnCardShelf, dmmConnCardSlot, dmmConnCardPortType }
::= { dmmConnTable 1 }
DmmConnEntry ::=
SEQUENCE
{
dmmConnCardLocation CardLocation,
dmmConnCardShelf CardShelf,
dmmConnCardSlot SlotInput,
dmmConnCardPortType INTEGER,
dmmConnCardType CardType,
dmmConnLocation CardLocation,
dmmConnShelf ShelfInput,
dmmConnSlot SlotInput,
dmmConnPort INTEGER
}
dmmConnCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { dmmConnEntry 1 }
dmmConnCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { dmmConnEntry 2 }
dmmConnCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { dmmConnEntry 3 }
dmmConnCardPortType OBJECT-TYPE
SYNTAX INTEGER { port1tx(1), port1rx(2), port2tx(3), port2rx(4), linktx(5), linkrx(6) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { dmmConnEntry 4 }
dmmConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module type connected to port."
::= { dmmConnEntry 5 }
dmmConnLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The chassis location of the card connected to
this port."
::= { dmmConnEntry 6 }
dmmConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the card connected to this port"
::= { dmmConnEntry 7 }
dmmConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot of the card connected to this port"
::= { dmmConnEntry 8 }
dmmConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Conn port for the DMM's port. Possible values based on
card types that can be connected to are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx.
Entry supported by all Mux modules except MD100-40 & BD4."
::= { dmmConnEntry 9 }
-- The elements in the ocm10gf subgroup of the configuration group
ocm10gfNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the ocm10gf table. This number
is automatically updated whenever a new row is added
to the table below."
::= { ocm10gf 1 }
ocm10gfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm10gfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
OCM10GF card"
::= { ocm10gf 2 }
ocm10gfEntry OBJECT-TYPE
SYNTAX Ocm10gfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm10gfCardLocation, ocm10gfCardShelf, ocm10gfCardSlot }
::= { ocm10gfTable 1 }
Ocm10gfEntry ::=
SEQUENCE
{
ocm10gfCardLocation CardLocation,
ocm10gfCardShelf CardShelf,
ocm10gfCardSlot INTEGER,
ocm10gfSerialNum SerialString,
ocm10gfModelNum DisplayString,
ocm10gfHwName DisplayString,
ocm10gfHwVersionID VersionString,
ocm10gfMfgDate DateAndTime,
ocm10gfFwName CardName,
ocm10gfFwVersionID VersionString,
ocm10gfFwDate DateAndTime,
ocm10gfModelType INTEGER,
ocm10gfName CardName,
ocm10gfLineRate INTEGER,
ocm10gfAutoDisable INTEGER,
ocm10gfLinkName LinkName,
ocm10gfPathID PathIdName,
ocm10gfAdminState INTEGER,
ocm10gfSetState INTEGER,
ocm10gfCleiNum DisplayString,
ocm10gfNumPorts INTEGER,
ocm10gfFpgaRev INTEGER
}
ocm10gfCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm10gfEntry 1 }
ocm10gfCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm10gfEntry 2 }
ocm10gfCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { ocm10gfEntry 3 }
ocm10gfSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { ocm10gfEntry 4 }
ocm10gfModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { ocm10gfEntry 5 }
ocm10gfHwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { ocm10gfEntry 6 }
ocm10gfHwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { ocm10gfEntry 7 }
ocm10gfMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { ocm10gfEntry 8 }
ocm10gfFwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { ocm10gfEntry 9 }
ocm10gfFwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { ocm10gfEntry 10 }
ocm10gfFwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { ocm10gfEntry 11 }
ocm10gfModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { ocm10gfEntry 12 }
ocm10gfName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { ocm10gfEntry 13 }
ocm10gfLineRate OBJECT-TYPE
SYNTAX INTEGER
{
gbE10(9),
fc10(11),
oc192nt(12),
oc192tr(13),
disabled(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port line rate. Valid only for ports 1 and 2."
::= { ocm10gfEntry 14 }
ocm10gfAutoDisable OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable the CPE link when a fault
is detected. Far end CPE disable is identical to normal
CPE disable with the added feature that the local
CPE Tx will be disabled if a loss of light condition
is detected on the remote CPE Rx."
::= { ocm10gfEntry 15 }
ocm10gfLinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link name for fiber between the local and the
remote card."
::= { ocm10gfEntry 16 }
ocm10gfPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that path."
::= { ocm10gfEntry 17 }
ocm10gfAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { ocm10gfEntry 18}
ocm10gfSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2),
enableLinkLoopback(3),
enableCpeLoopback(4),
disableloopback(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot. A get on this will
always return 'other'."
::= { ocm10gfEntry 19 }
ocm10gfCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the module."
::= { ocm10gfEntry 20 }
ocm10gfNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each OCM10GF card."
::= { ocm10gfEntry 21 }
ocm10gfFpgaRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA revision for the module."
::= { ocm10gfEntry 22 }
ocm10gfPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm10gfPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { ocm10gf 3 }
ocm10gfPortEntry OBJECT-TYPE
SYNTAX Ocm10gfPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm10gfPortLocation, ocm10gfPortShelf, ocm10gfPortSlot, ocm10gfPortIndex }
::= { ocm10gfPortTable 1 }
Ocm10gfPortEntry ::=
SEQUENCE
{
ocm10gfPortLocation CardLocation,
ocm10gfPortShelf CardShelf,
ocm10gfPortSlot SlotInput,
ocm10gfPortIndex INTEGER,
ocm10gfPortMode INTEGER,
ocm10gfPortWavelength DisplayString,
ocm10gfPortRxPower DisplayString,
ocm10gfPortTxState INTEGER,
ocm10gfPortTxReach INTEGER,
ocm10gfPortXfpSerialNumber DisplayString
}
ocm10gfPortLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm10gfPortEntry 1 }
ocm10gfPortShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm10gfPortEntry 2 }
ocm10gfPortSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { ocm10gfPortEntry 3 }
ocm10gfPortIndex OBJECT-TYPE
SYNTAX INTEGER { link(1), cpe(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { ocm10gfPortEntry 4 }
ocm10gfPortMode OBJECT-TYPE
SYNTAX INTEGER { disabled(1), enabled(2), loopback(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port mode."
::= { ocm10gfPortEntry 5 }
ocm10gfPortWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wavelength from port SFP."
::= { ocm10gfPortEntry 6 }
ocm10gfPortRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive power reported by port SFP."
::= { ocm10gfPortEntry 7 }
ocm10gfPortTxState OBJECT-TYPE
SYNTAX INTEGER { na(0), on(1), off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of port SFP transmitter."
::= { ocm10gfPortEntry 8 }
ocm10gfPortTxReach OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical reach in meters reported by port SFP."
::= { ocm10gfPortEntry 9 }
ocm10gfPortXfpSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port SFP serial number."
::= { ocm10gfPortEntry 10 }
ocm10gfConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm10gfConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { ocm10gf 4 }
ocm10gfConnEntry OBJECT-TYPE
SYNTAX Ocm10gfConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm10gfConnCardLocation, ocm10gfConnCardShelf, ocm10gfConnCardSlot, ocm10gfConnCardPortType }
::= { ocm10gfConnTable 1 }
Ocm10gfConnEntry ::=
SEQUENCE
{
ocm10gfConnCardLocation CardLocation,
ocm10gfConnCardShelf CardShelf,
ocm10gfConnCardSlot SlotInput,
ocm10gfConnCardPortType INTEGER,
ocm10gfConnCardType CardType,
ocm10gfConnLocation CardLocation,
ocm10gfConnShelf ShelfInput,
ocm10gfConnSlot SlotInput,
ocm10gfConnPort INTEGER
}
ocm10gfConnCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm10gfConnEntry 1 }
ocm10gfConnCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm10gfConnEntry 2 }
ocm10gfConnCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { ocm10gfConnEntry 3 }
ocm10gfConnCardPortType OBJECT-TYPE
SYNTAX INTEGER { linktx(1), linkrx(2), cpetx(3), cperx(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { ocm10gfConnEntry 4 }
ocm10gfConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module type connected to port."
::= { ocm10gfConnEntry 5 }
ocm10gfConnLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The chassis location of the card connected to
this port."
::= { ocm10gfConnEntry 6 }
ocm10gfConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the card connected to this port"
::= { ocm10gfConnEntry 7 }
ocm10gfConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot of the card connected to this port"
::= { ocm10gfConnEntry 8 }
ocm10gfConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Conn port for the OCM10GF's port. Possible values based on
card types that can be connected to are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx.
Entry supported by all Mux modules except MD100-40 & BD4."
::= { ocm10gfConnEntry 9 }
-- The elements in the fc8g subgroup of the configuration group
fc8gNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the fc8g table. This number
is automatically updated whenever a new row is added
to the table below."
::= { fc8g 1 }
fc8gTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fc8gEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
FC8G card"
::= { fc8g 2 }
fc8gEntry OBJECT-TYPE
SYNTAX Fc8gEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fc8gCardLocation, fc8gCardShelf, fc8gCardSlot }
::= { fc8gTable 1 }
Fc8gEntry ::=
SEQUENCE
{
fc8gCardLocation INTEGER,
fc8gCardShelf CardShelf,
fc8gCardSlot INTEGER,
fc8gSerialNum SerialString,
fc8gModelNum DisplayString,
fc8gHwName DisplayString,
fc8gHwVersionID VersionString,
fc8gMfgDate DateAndTime,
fc8gFwName CardName,
fc8gFwVersionID VersionString,
fc8gFwDate DateAndTime,
fc8gModelType INTEGER,
fc8gName CardName,
fc8gLink1DataRate INTEGER,
fc8gCpe1AutoDisable INTEGER,
fc8gCpe1LaserEnabled INTEGER,
fc8gLink1LaserEnabled INTEGER,
fc8gLink2DataRate INTEGER,
fc8gCpe2AutoDisable INTEGER,
fc8gCpe2LaserEnabled INTEGER,
fc8gLink2LaserEnabled INTEGER,
fc8gAdminState INTEGER,
fc8gSetState INTEGER
}
fc8gCardLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { fc8gEntry 1 }
fc8gCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { fc8gEntry 2 }
fc8gCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { fc8gEntry 3 }
fc8gSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { fc8gEntry 4 }
fc8gModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { fc8gEntry 5 }
fc8gHwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { fc8gEntry 6 }
fc8gHwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { fc8gEntry 7 }
fc8gMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { fc8gEntry 8 }
fc8gFwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { fc8gEntry 9 }
fc8gFwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { fc8gEntry 10 }
fc8gFwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { fc8gEntry 11 }
fc8gModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { fc8gEntry 12 }
fc8gName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { fc8gEntry 13 }
fc8gLink1DataRate OBJECT-TYPE
SYNTAX INTEGER
{
dr8G(1),
dr4G(2),
dr2G(3),
dr1G(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 1 Data rate."
::= { fc8gEntry 14 }
fc8gCpe1AutoDisable OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable automatic CPE disable for Link 1."
::= { fc8gEntry 15 }
fc8gCpe1LaserEnabled OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable the CPE laser for Link 1."
::= { fc8gEntry 16 }
fc8gLink1LaserEnabled OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable the LINK laser for Link 1."
::= { fc8gEntry 17 }
fc8gLink2DataRate OBJECT-TYPE
SYNTAX INTEGER
{
dr8G(1),
dr4G(2),
dr2G(3),
dr1G(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 2 Data rate."
::= { fc8gEntry 18 }
fc8gCpe2AutoDisable OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable automatic CPE disable for Link 2."
::= { fc8gEntry 19 }
fc8gCpe2LaserEnabled OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable the CPE laser for Link 2."
::= { fc8gEntry 20 }
fc8gLink2LaserEnabled OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable the LINK laser for Link 2."
::= { fc8gEntry 21 }
fc8gAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { fc8gEntry 22 }
fc8gSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2),
enableChannel1LinkLoopback(3),
enableChannel1CpeLoopback(4),
enableChannel2LinkLoopback(5),
enableChannel2CpeLoopback(6),
disableChannel1loopback(7),
disableChannel2loopback(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot or loopback. Successive loopbacks can be issued.
A get on this will always return 'other'."
::= { fc8gEntry 23 }
fc8gPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fc8gPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { fc8g 3 }
fc8gPortEntry OBJECT-TYPE
SYNTAX Fc8gPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fc8gPortLocation, fc8gPortShelf, fc8gPortSlot, fc8gPortIndex }
::= { fc8gPortTable 1 }
Fc8gPortEntry ::=
SEQUENCE
{
fc8gPortLocation CardLocation,
fc8gPortShelf CardShelf,
fc8gPortSlot SlotInput,
fc8gPortIndex INTEGER,
fc8gPortName CardName,
fc8gPortMode INTEGER,
fc8gPortWavelength DisplayString,
fc8gPortRxPower DisplayString,
fc8gPortTxState INTEGER,
fc8gPortTxReach INTEGER,
fc8gPortSfpXfpSerialNumber DisplayString
}
fc8gPortLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { fc8gPortEntry 1 }
fc8gPortShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { fc8gPortEntry 2 }
fc8gPortSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { fc8gPortEntry 3 }
fc8gPortIndex OBJECT-TYPE
SYNTAX INTEGER { link1(1), cpe1(2), link2(3), cpe2(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { fc8gPortEntry 4 }
fc8gPortName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port name."
::= { fc8gPortEntry 5 }
fc8gPortMode OBJECT-TYPE
SYNTAX INTEGER { enabled(1), loopback(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port mode."
::= { fc8gPortEntry 6 }
fc8gPortWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port wavelength."
::= { fc8gPortEntry 7 }
fc8gPortRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reported port receive power."
::= { fc8gPortEntry 8 }
fc8gPortTxState OBJECT-TYPE
SYNTAX INTEGER { na(0), on(1), off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of port transmitter."
::= { fc8gPortEntry 9 }
fc8gPortTxReach OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port optical reach in meters."
::= { fc8gPortEntry 10 }
fc8gPortSfpXfpSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port SFP/XFP serial number."
::= { fc8gPortEntry 11 }
-- The elements in the ocm2 subgroup of the configuration group
ocm2Number OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the ocm2 table. This number
is automatically updated whenever a new row is added
to the table below."
::= { ocm2 1 }
ocm2Table OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
OCM2 card"
::= { ocm2 2 }
ocm2Entry OBJECT-TYPE
SYNTAX Ocm2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm2CardLocation, ocm2CardShelf, ocm2CardSlot }
::= { ocm2Table 1 }
Ocm2Entry ::=
SEQUENCE
{
ocm2CardLocation CardLocation,
ocm2CardShelf CardShelf,
ocm2CardSlot INTEGER,
ocm2SerialNum SerialString,
ocm2ModelNum DisplayString,
ocm2HwName DisplayString,
ocm2HwVersionID VersionString,
ocm2MfgDate DateAndTime,
ocm2FwName CardName,
ocm2FwVersionID VersionString,
ocm2FwDate DateAndTime,
ocm2ModelType INTEGER,
ocm2Name CardName,
ocm2Link1LineRate INTEGER,
ocm2Link1AutoDisable INTEGER,
ocm2Link1LinkName LinkName,
ocm2Link1PathID PathIdName,
ocm2Link2LineRate INTEGER,
ocm2Link2AutoDisable INTEGER,
ocm2Link2LinkName LinkName,
ocm2Link2PathID PathIdName,
ocm2AdminState INTEGER,
ocm2SetState INTEGER,
ocm2CleiNum DisplayString,
ocm2NumPorts INTEGER,
ocm2RegenMode INTEGER,
ocm2FpgaRev INTEGER
}
ocm2CardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm2Entry 1 }
ocm2CardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm2Entry 2 }
ocm2CardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { ocm2Entry 3 }
ocm2SerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { ocm2Entry 4 }
ocm2ModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { ocm2Entry 5 }
ocm2HwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { ocm2Entry 6 }
ocm2HwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { ocm2Entry 7 }
ocm2MfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { ocm2Entry 8 }
ocm2FwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { ocm2Entry 9 }
ocm2FwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { ocm2Entry 10 }
ocm2FwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { ocm2Entry 11 }
ocm2ModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { ocm2Entry 12 }
ocm2Name OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { ocm2Entry 13 }
ocm2Link1LineRate OBJECT-TYPE
SYNTAX INTEGER
{
na(0),
oc3(1),
oc12(2),
oc48(3),
gbe(4),
fc(5),
escon(8),
fc2(10),
hlf_fc(14),
infiniband(15),
disabled(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 1 line rate."
::= { ocm2Entry 14 }
ocm2Link1AutoDisable OBJECT-TYPE
SYNTAX INTEGER { na(0), enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable automatic CPE disable for Link 1."
::= { ocm2Entry 15 }
ocm2Link1LinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 1 link name for fiber between the local and the
remote card."
::= { ocm2Entry 16 }
ocm2Link1PathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 1 path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that path."
::= { ocm2Entry 17 }
ocm2Link2LineRate OBJECT-TYPE
SYNTAX INTEGER
{
na(0),
oc3(1),
oc12(2),
oc48(3),
gbe(4),
fc(5),
escon(8),
fc2(10),
hlf_fc(14),
infiniband(15),
disabled(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 2 line rate."
::= { ocm2Entry 18 }
ocm2Link2AutoDisable OBJECT-TYPE
SYNTAX INTEGER { na(0), enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable automatic CPE disable for Link 2."
::= { ocm2Entry 19 }
ocm2Link2LinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 2 link name for fiber between the local and the
remote card."
::= { ocm2Entry 20 }
ocm2Link2PathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 2 path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that path."
::= { ocm2Entry 21 }
ocm2AdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { ocm2Entry 22 }
ocm2SetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2),
enableLink1Loopback(3),
enableLink2Loopback(4),
disableLink1loopback(5),
disableLink2loopback(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot. A get on this will
always return 'other'."
::= { ocm2Entry 23 }
ocm2CleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the module."
::= { ocm2Entry 24 }
ocm2NumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each OCM2 card."
::= { ocm2Entry 25 }
ocm2RegenMode OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set or clear OCM2 regen mode."
::= { ocm2Entry 26 }
ocm2FpgaRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA revision for the module."
::= { ocm2Entry 27 }
ocm2PortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm2PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { ocm2 3 }
ocm2PortEntry OBJECT-TYPE
SYNTAX Ocm2PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm2PortLocation, ocm2PortShelf, ocm2PortSlot, ocm2PortIndex }
::= { ocm2PortTable 1 }
Ocm2PortEntry ::=
SEQUENCE
{
ocm2PortLocation CardLocation,
ocm2PortShelf CardShelf,
ocm2PortSlot SlotInput,
ocm2PortIndex INTEGER,
ocm2PortMode INTEGER,
ocm2PortItu INTEGER,
ocm2PortWavelength DisplayString,
ocm2PortRxPower DisplayString,
ocm2PortTxState INTEGER,
ocm2PortTxReach INTEGER,
ocm2PortSfpSerialNumber DisplayString
}
ocm2PortLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm2PortEntry 1 }
ocm2PortShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm2PortEntry 2 }
ocm2PortSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { ocm2PortEntry 3 }
ocm2PortIndex OBJECT-TYPE
SYNTAX INTEGER { link1(1), cpe1(2), link2(3), cpe2(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { ocm2PortEntry 4 }
ocm2PortMode OBJECT-TYPE
SYNTAX INTEGER { na(0), disabled(1), enabled(2), loopback(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port mode."
::= { ocm2PortEntry 5 }
ocm2PortItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port ITU number. The ITU number is determined
from the SFP wavelength."
::= { ocm2PortEntry 6 }
ocm2PortWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wavelength from port SFP."
::= { ocm2PortEntry 7 }
ocm2PortRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive power reported by port SFP."
::= { ocm2PortEntry 8 }
ocm2PortTxState OBJECT-TYPE
SYNTAX INTEGER { na(0), on(1), off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of port SFP transmitter."
::= { ocm2PortEntry 9 }
ocm2PortTxReach OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical reach in meters reported by port SFP."
::= { ocm2PortEntry 10 }
ocm2PortSfpSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port SFP serial number."
::= { ocm2PortEntry 11 }
ocm2ConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm2ConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { ocm2 4 }
ocm2ConnEntry OBJECT-TYPE
SYNTAX Ocm2ConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm2ConnCardLocation, ocm2ConnCardShelf, ocm2ConnCardSlot, ocm2ConnCardPortType }
::= { ocm2ConnTable 1 }
Ocm2ConnEntry ::=
SEQUENCE
{
ocm2ConnCardLocation CardLocation,
ocm2ConnCardShelf CardShelf,
ocm2ConnCardSlot SlotInput,
ocm2ConnCardPortType INTEGER,
ocm2ConnCardType CardType,
ocm2ConnLocation CardLocation,
ocm2ConnShelf ShelfInput,
ocm2ConnSlot SlotInput,
ocm2ConnPort INTEGER
}
ocm2ConnCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm2ConnEntry 1 }
ocm2ConnCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm2ConnEntry 2 }
ocm2ConnCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { ocm2ConnEntry 3 }
ocm2ConnCardPortType OBJECT-TYPE
SYNTAX INTEGER { link1tx(1), link1rx(2), link2tx(3), link2rx(4), cpe1tx(5), cpe1rx(6), cpe2tx(7), cpe2rx(8) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { ocm2ConnEntry 4 }
ocm2ConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module type connected to port."
::= { ocm2ConnEntry 5 }
ocm2ConnLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The chassis location of the card connected to
this port."
::= { ocm2ConnEntry 6 }
ocm2ConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the card connected to this port"
::= { ocm2ConnEntry 7 }
ocm2ConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot of the card connected to this port"
::= { ocm2ConnEntry 8 }
ocm2ConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Conn port for the OCM2's port. Possible values based on
card types that can be connected to are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx.
Entry supported by all Mux modules except MD100-40 & BD4."
::= { ocm2ConnEntry 9 }
-- The elements in the osc subgroup of the configuration group
oscNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the osc table. This number
is automatically updated whenever a new row is added
to the table below."
::= { osc 1 }
oscTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
OSC card"
::= { osc 2 }
oscEntry OBJECT-TYPE
SYNTAX OscEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oscCardLocation, oscCardShelf, oscCardSlot }
::= { oscTable 1 }
OscEntry ::=
SEQUENCE
{
oscCardLocation CardLocation,
oscCardShelf CardShelf,
oscCardSlot INTEGER,
oscSerialNum SerialString,
oscModelNum DisplayString,
oscHwName DisplayString,
oscHwVersionID VersionString,
oscMfgDate DateAndTime,
oscFwName CardName,
oscFwVersionID VersionString,
oscFwDate DateAndTime,
oscAdminState INTEGER,
oscModelType INTEGER,
oscName CardName,
oscPathID PathIdName,
oscSetState INTEGER,
oscCleiNum DisplayString,
oscNumPorts INTEGER,
oscFpgaRev INTEGER
}
oscCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { oscEntry 1 }
oscCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { oscEntry 2 }
oscCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { oscEntry 3 }
oscSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { oscEntry 4 }
oscModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { oscEntry 5 }
oscHwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { oscEntry 6 }
oscHwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { oscEntry 7 }
oscMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { oscEntry 8 }
oscFwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { oscEntry 9 }
oscFwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { oscEntry 10 }
oscFwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { oscEntry 11 }
oscAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { oscEntry 12}
oscModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { oscEntry 13 }
oscName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { oscEntry 14 }
oscPathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that path."
::= { oscEntry 15 }
oscSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot. A get on this will
always return 'other'."
::= { oscEntry 16 }
oscCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the module."
::= { oscEntry 17 }
oscNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each OSC card."
::= { oscEntry 18 }
oscFpgaRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA revision for the module."
::= { oscEntry 19 }
oscPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { osc 3 }
oscPortEntry OBJECT-TYPE
SYNTAX OscPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oscPortLocation, oscPortShelf, oscPortSlot, oscPortIndex }
::= { oscPortTable 1 }
OscPortEntry ::=
SEQUENCE
{
oscPortLocation CardLocation,
oscPortShelf CardShelf,
oscPortSlot SlotInput,
oscPortIndex INTEGER,
oscPortItu INTEGER,
oscPortWavelength DisplayString,
oscPortRxPower DisplayString,
oscPortTxState INTEGER,
oscPortTxReach INTEGER,
oscPortSfpSerialNumber DisplayString
}
oscPortLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { oscPortEntry 1 }
oscPortShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { oscPortEntry 2 }
oscPortSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { oscPortEntry 3 }
oscPortIndex OBJECT-TYPE
SYNTAX INTEGER { link(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { oscPortEntry 4 }
oscPortItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port ITU number. The ITU number is determined
from the SFP wavelength."
::= { oscPortEntry 5 }
oscPortWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wavelength from port SFP."
::= { oscPortEntry 6 }
oscPortRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive power reported by port SFP."
::= { oscPortEntry 7}
oscPortTxState OBJECT-TYPE
SYNTAX INTEGER { na(0), on(1), off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of port SFP transmitter."
::= { oscPortEntry 8 }
oscPortTxReach OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical reach in meters reported by port SFP."
::= { oscPortEntry 9 }
oscPortSfpSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port SFP serial number."
::= { oscPortEntry 10 }
-- The elements in the ocm4g subgroup of the configuration group
ocm4gNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the ocm4g table. This number
is automatically updated whenever a new row is added
to the table below."
::= { ocm4g 1 }
ocm4gTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm4gEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
OCM4G card"
::= { ocm4g 2 }
ocm4gEntry OBJECT-TYPE
SYNTAX Ocm4gEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm4gCardLocation, ocm4gCardShelf, ocm4gCardSlot }
::= { ocm4gTable 1 }
Ocm4gEntry ::=
SEQUENCE
{
ocm4gCardLocation INTEGER,
ocm4gCardShelf CardShelf,
ocm4gCardSlot INTEGER,
ocm4gSerialNum SerialString,
ocm4gModelNum DisplayString,
ocm4gHwName DisplayString,
ocm4gHwVersionID VersionString,
ocm4gMfgDate DateAndTime,
ocm4gFwName CardName,
ocm4gFwVersionID VersionString,
ocm4gFwDate DateAndTime,
ocm4gModelType INTEGER,
ocm4gName CardName,
ocm4gLink1LineRate INTEGER,
ocm4gLink1AutoDisable INTEGER,
ocm4gLink1LinkName LinkName,
ocm4gLink1PathID PathIdName,
ocm4gLink2LineRate INTEGER,
ocm4gLink2AutoDisable INTEGER,
ocm4gLink2LinkName LinkName,
ocm4gLink2PathID PathIdName,
ocm4gAdminState INTEGER,
ocm4gSetState INTEGER,
ocm4gCleiNum DisplayString,
ocm4gNumPorts INTEGER,
ocm4gFpgaRev INTEGER
}
ocm4gCardLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm4gEntry 1 }
ocm4gCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm4gEntry 2 }
ocm4gCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { ocm4gEntry 3 }
ocm4gSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { ocm4gEntry 4 }
ocm4gModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { ocm4gEntry 5 }
ocm4gHwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { ocm4gEntry 6 }
ocm4gHwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { ocm4gEntry 7 }
ocm4gMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { ocm4gEntry 8 }
ocm4gFwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { ocm4gEntry 9 }
ocm4gFwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { ocm4gEntry 10 }
ocm4gFwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { ocm4gEntry 11 }
ocm4gModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { ocm4gEntry 12 }
ocm4gName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { ocm4gEntry 13 }
ocm4gLink1LineRate OBJECT-TYPE
SYNTAX INTEGER
{
na(0),
oc3(1),
oc12(2),
oc48(3),
gbe(4),
fc(5),
escon(8),
fc2(10),
hlf_fc(14),
infiniband(15),
fourG(16),
twoR(17),
disabled(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 1 line rate."
::= { ocm4gEntry 14 }
ocm4gLink1AutoDisable OBJECT-TYPE
SYNTAX INTEGER { na(0), enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable automatic CPE disable for Link 1."
::= { ocm4gEntry 15 }
ocm4gLink1LinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 1 link name for fiber between the local and the
remote card."
::= { ocm4gEntry 16 }
ocm4gLink1PathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 1 path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that path."
::= { ocm4gEntry 17 }
ocm4gLink2LineRate OBJECT-TYPE
SYNTAX INTEGER
{
na(0),
oc3(1),
oc12(2),
oc48(3),
gbe(4),
fc(5),
escon(8),
fc2(10),
hlf_fc(14),
infiniband(15),
fourG(16),
twoR(17),
disabled(255)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 2 line rate."
::= { ocm4gEntry 18 }
ocm4gLink2AutoDisable OBJECT-TYPE
SYNTAX INTEGER { na(0), enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flag to enable/disable automatic CPE disable for Link 2."
::= { ocm4gEntry 19 }
ocm4gLink2LinkName OBJECT-TYPE
SYNTAX LinkName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 2 link name for fiber between the local and the
remote card."
::= { ocm4gEntry 20 }
ocm4gLink2PathID OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link 2 path ID name associated with the module. Set input
equal to NULL will remove the card off the path
and also remove the path if no other modules are
associated with that path."
::= { ocm4gEntry 21 }
ocm4gAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { ocm4gEntry 22 }
ocm4gSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2),
enableLink1Loopback(3),
enableLink2Loopback(4),
disableLink1loopback(5),
disableLink2loopback(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot. A get on this will
always return 'other'."
::= { ocm4gEntry 23 }
ocm4gCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the module."
::= { ocm4gEntry 24 }
ocm4gNumPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total port numbers on each OCM4G card."
::= { ocm4gEntry 25 }
ocm4gFpgaRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA revision for the module."
::= { ocm4gEntry 26 }
ocm4gPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm4gPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { ocm4g 3 }
ocm4gPortEntry OBJECT-TYPE
SYNTAX Ocm4gPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm4gPortLocation, ocm4gPortShelf, ocm4gPortSlot, ocm4gPortIndex }
::= { ocm4gPortTable 1 }
Ocm4gPortEntry ::=
SEQUENCE
{
ocm4gPortLocation INTEGER,
ocm4gPortShelf CardShelf,
ocm4gPortSlot SlotInput,
ocm4gPortIndex INTEGER,
ocm4gPortMode INTEGER,
ocm4gPortItu INTEGER,
ocm4gPortWavelength DisplayString,
ocm4gPortRxPower DisplayString,
ocm4gPortTxState INTEGER,
ocm4gPortTxReach INTEGER,
ocm4gPortSfpSerialNumber DisplayString
}
ocm4gPortLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm4gPortEntry 1 }
ocm4gPortShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm4gPortEntry 2 }
ocm4gPortSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { ocm4gPortEntry 3 }
ocm4gPortIndex OBJECT-TYPE
SYNTAX INTEGER { link1(1), cpe1(2), link2(3), cpe2(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { ocm4gPortEntry 4 }
ocm4gPortMode OBJECT-TYPE
SYNTAX INTEGER { na(0), disabled(1), enabled(2), loopback(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port mode."
::= { ocm4gPortEntry 5 }
ocm4gPortItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port ITU number. The ITU number is determined
from the SFP wavelength."
::= { ocm4gPortEntry 6 }
ocm4gPortWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wavelength from port SFP."
::= { ocm4gPortEntry 7 }
ocm4gPortRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive power reported by port SFP."
::= { ocm4gPortEntry 8 }
ocm4gPortTxState OBJECT-TYPE
SYNTAX INTEGER { na(0), on(1), off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of port SFP transmitter."
::= { ocm4gPortEntry 9 }
ocm4gPortTxReach OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical reach in meters reported by port SFP."
::= { ocm4gPortEntry 10 }
ocm4gPortSfpSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port SFP serial number."
::= { ocm4gPortEntry 11 }
ocm4gConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm4gConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each set
of ports on the module. Ports are divided into two
sets: mux ports and demux ports."
::= { ocm4g 4 }
ocm4gConnEntry OBJECT-TYPE
SYNTAX Ocm4gConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm4gConnCardLocation, ocm4gConnCardShelf, ocm4gConnCardSlot, ocm4gConnCardPortType }
::= { ocm4gConnTable 1 }
Ocm4gConnEntry ::=
SEQUENCE
{
ocm4gConnCardLocation INTEGER,
ocm4gConnCardShelf CardShelf,
ocm4gConnCardSlot SlotInput,
ocm4gConnCardPortType INTEGER,
ocm4gConnCardType CardType,
ocm4gConnLocation INTEGER,
ocm4gConnShelf ShelfInput,
ocm4gConnSlot SlotInput,
ocm4gConnPort INTEGER
}
ocm4gConnCardLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { ocm4gConnEntry 1 }
ocm4gConnCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { ocm4gConnEntry 2 }
ocm4gConnCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { ocm4gConnEntry 3 }
ocm4gConnCardPortType OBJECT-TYPE
SYNTAX INTEGER { link1tx(1), link1rx(2), link2tx(3), link2rx(4), cpe1tx(5), cpe1rx(6), cpe2tx(7), cpe2rx(8) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { ocm4gConnEntry 4 }
ocm4gConnCardType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module type connected to port."
::= { ocm4gConnEntry 5 }
ocm4gConnLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The chassis location of the card connected to
this port."
::= { ocm4gConnEntry 6 }
ocm4gConnShelf OBJECT-TYPE
SYNTAX ShelfInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the card connected to this port"
::= { ocm4gConnEntry 7 }
ocm4gConnSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot of the card connected to this port"
::= { ocm4gConnEntry 8 }
ocm4gConnPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Conn port for the OCM4G's port. Possible values based on
card types that can be connected to are:
FADM: 1=Conn A Tx, 2=Conn A Rx, 3=Local Tx
4=Local Rx, 5=Conn B Tx, 6=Conn B Rx
OCM10G/OCME/OCMITU/OCMU/MCMT1/MCME1/MCMESC: 1=Link Tx, 2=Link Rx
OFCM/OFCD: 1/2/3/4=port index, 5=EXP, 6=OUT/IN
OSAM: 1=IN, 2=OUT
W2CM/W2CMD:1=13M, 2=15M, 3=13D, 4=15D, 5=IN , 6=OUT
W4CM/W4CD: 1=1470/1510, 2=1490/1530, 3=1550/1590, 4=1570/1610, 5=EXP, 6=IN/OUT
UPSM/OPPM: 1=Link A Tx, 2=Link A Rx, 3=Link B Tx,
4=Link B Rx, 5=Local Tx, 6=Local Rx.
Entry supported by all Mux modules except MD100-40 & BD4."
::= { ocm4gConnEntry 9 }
-- The elements in the oet subgroup of the configuration group
oetNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the oet table. This number
is automatically updated whenever a new row is added
to the table below."
::= { oet 1 }
oetTable OBJECT-TYPE
SYNTAX SEQUENCE OF OetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
OET card"
::= { oet 2 }
oetEntry OBJECT-TYPE
SYNTAX OetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oetCardLocation, oetCardShelf, oetCardSlot }
::= { oetTable 1 }
OetEntry ::=
SEQUENCE
{
oetCardLocation CardLocation,
oetCardShelf CardShelf,
oetCardSlot INTEGER,
oetSerialNum SerialString,
oetModelNum DisplayString,
oetHwName DisplayString,
oetHwVersionID VersionString,
oetMfgDate DateAndTime,
oetFwName CardName,
oetFwVersionID VersionString,
oetFwDate DateAndTime,
oetModelType INTEGER,
oetName CardName,
oetCleiNum DisplayString,
oetFpgaRevMB INTEGER,
oetFpgaRevDB INTEGER,
oetCpldRev INTEGER,
oetOpMode INTEGER,
oetProtMode INTEGER,
oetEAPSMode INTEGER,
oetAdminState INTEGER,
oetSetState INTEGER,
oetConfigInProgress INTEGER,
oetApplyChanges INTEGER
}
oetCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { oetEntry 1 }
oetCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { oetEntry 2 }
oetCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { oetEntry 3 }
oetSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { oetEntry 4 }
oetModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { oetEntry 5 }
oetHwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { oetEntry 6 }
oetHwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { oetEntry 7 }
oetMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { oetEntry 8 }
oetFwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { oetEntry 9 }
oetFwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { oetEntry 10 }
oetFwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { oetEntry 11 }
oetModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { oetEntry 12 }
oetName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { oetEntry 13 }
oetCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the module."
::= { oetEntry 14 }
oetFpgaRevMB OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA revision for the module's mother board."
::= { oetEntry 15 }
oetFpgaRevDB OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA revision for the module's daughter board."
::= { oetEntry 16 }
oetCpldRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPLD revision for the module."
::= { oetEntry 17 }
oetOpMode OBJECT-TYPE
SYNTAX INTEGER { mux(1), switch(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Operating Mode (1=Mux Mode, 2=Switch Mode)."
::= { oetEntry 18 }
oetProtMode OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mux Protection."
::= { oetEntry 19 }
oetEAPSMode OBJECT-TYPE
SYNTAX INTEGER { disabled(1), linearEndpoint(2), linearNode(3),
ringMaster(4), ringNode(5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Ethernet Automatic Protection Switching."
::= { oetEntry 20 }
oetAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { oetEntry 21 }
oetSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot. A get on this will
always return 'other'."
::= { oetEntry 22 }
oetConfigInProgress OBJECT-TYPE
SYNTAX INTEGER { yes(1), on(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Configured changes are pending, Apply Changes required
to finish."
::= { oetEntry 23 }
oetApplyChanges OBJECT-TYPE
SYNTAX INTEGER { clear(1), apply(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Update device with pending configuration changes.
Read returns 'na'."
::= { oetEntry 24 }
oetLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF OetLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each of
the Link ports on the module."
::= { oet 3 }
oetLinkEntry OBJECT-TYPE
SYNTAX OetLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oetLinkLocation, oetLinkShelf, oetLinkSlot, oetLinkIndex }
::= { oetLinkTable 1 }
OetLinkEntry ::=
SEQUENCE
{
oetLinkLocation CardLocation,
oetLinkShelf CardShelf,
oetLinkSlot SlotInput,
oetLinkIndex INTEGER,
oetLinkEnable INTEGER,
oetLinkProtocol INTEGER,
oetLinkName CardName,
oetLinkVlanIds DisplayString,
oetLinkConfigInProgress INTEGER,
oetLinkApplyChanges INTEGER,
oetLinkMode INTEGER,
oetLinkItu INTEGER,
oetLinkWavelength DisplayString,
oetLinkRxPower DisplayString,
oetLinkTxState INTEGER,
oetLinkTxReach INTEGER,
oetLinkXfpSerialNumber DisplayString
}
oetLinkLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { oetLinkEntry 1 }
oetLinkShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { oetLinkEntry 2 }
oetLinkSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { oetLinkEntry 3 }
oetLinkIndex OBJECT-TYPE
SYNTAX INTEGER { linkA(11), linkB(12) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link for which the below values apply."
::= { oetLinkEntry 4 }
oetLinkEnable OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or disables the link."
::= { oetLinkEntry 5 }
oetLinkProtocol OBJECT-TYPE
SYNTAX INTEGER { otu(1), lan(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Protocol."
::= { oetLinkEntry 6 }
oetLinkName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Link name for fiber between the local and the
remote card."
::= { oetLinkEntry 7 }
oetLinkVlanIds OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Comma List of VLAN Ids - single and ranges."
::= { oetLinkEntry 8 }
oetLinkConfigInProgress OBJECT-TYPE
SYNTAX INTEGER { yes(1), on(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Configured changes are pending, Apply Changes required
to finish."
::= { oetLinkEntry 9 }
oetLinkApplyChanges OBJECT-TYPE
SYNTAX INTEGER { clear(1), apply(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Update device with pending configuration changes.
Read returns 'na'."
::= { oetLinkEntry 10 }
oetLinkMode OBJECT-TYPE
SYNTAX INTEGER { na(0), disabled(1), enabled(2), loopback(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link mode."
::= { oetLinkEntry 11 }
oetLinkItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link ITU number. The ITU number is determined
from the XFP wavelength."
::= { oetLinkEntry 12 }
oetLinkWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wavelength from Link XFP."
::= { oetLinkEntry 13 }
oetLinkRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive power reported by Link XFP."
::= { oetLinkEntry 14 }
oetLinkTxState OBJECT-TYPE
SYNTAX INTEGER { na(0), on(1), off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of Link XFP transmitter."
::= { oetLinkEntry 15 }
oetLinkTxReach OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical reach in meters reported by Link XFP."
::= { oetLinkEntry 16 }
oetLinkXfpSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link XFP serial number."
::= { oetLinkEntry 17 }
oetPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OetPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each of
the CPE ports on the module."
::= { oet 4 }
oetPortEntry OBJECT-TYPE
SYNTAX OetPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oetPortLocation, oetPortShelf, oetPortSlot, oetPortIndex }
::= { oetPortTable 1 }
OetPortEntry ::=
SEQUENCE
{
oetPortLocation CardLocation,
oetPortShelf CardShelf,
oetPortSlot SlotInput,
oetPortIndex INTEGER,
oetPortEnable INTEGER,
oetPortALSD INTEGER,
oetPortFlowControl INTEGER,
oetPortVlanId INTEGER,
oetPortName CardName,
oetPortConfigInProgress INTEGER,
oetPortApplyChanges INTEGER,
oetPortMode INTEGER,
oetPortItu INTEGER,
oetPortWavelength DisplayString,
oetPortRxPower DisplayString,
oetPortTxState INTEGER,
oetPortTxReach INTEGER,
oetPortSfpSerialNumber DisplayString
}
oetPortLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { oetPortEntry 1 }
oetPortShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { oetPortEntry 2 }
oetPortSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides."
::= { oetPortEntry 3 }
oetPortIndex OBJECT-TYPE
SYNTAX INTEGER { cpe(1), cpe(2), cpe(3), cpe(4), cpe(5),
cpe(6), cpe(7), cpe(8), cpe(9), cpe(10)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the below values apply."
::= { oetPortEntry 4 }
oetPortEnable OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or disables the port."
::= { oetPortEntry 5 }
oetPortALSD OBJECT-TYPE
SYNTAX INTEGER { disabled(1), local(2), remote(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Auto Laser Shutoff"
::= { oetPortEntry 6 }
oetPortFlowControl OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable the port's flow control."
::= { oetPortEntry 7 }
oetPortVlanId OBJECT-TYPE
SYNTAX INTEGER(1..200)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Network ID must be between 1 to 200."
::= { oetPortEntry 8 }
oetPortName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port name."
::= { oetPortEntry 9 }
oetPortConfigInProgress OBJECT-TYPE
SYNTAX INTEGER { yes(1), on(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Configured changes are pending, Apply Changes required
to finish."
::= { oetPortEntry 10 }
oetPortApplyChanges OBJECT-TYPE
SYNTAX INTEGER { clear(1), apply(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Update device with pending configuration changes.
Read returns 'na'."
::= { oetPortEntry 11 }
oetPortMode OBJECT-TYPE
SYNTAX INTEGER { na(0), disabled(1), enabled(2), loopback(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port mode."
::= { oetPortEntry 12 }
oetPortItu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port ITU number. The ITU number is determined
from the SFP wavelength."
::= { oetPortEntry 13 }
oetPortWavelength OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Wavelength from Port SFP."
::= { oetPortEntry 14 }
oetPortRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receive power reported by Port SFP."
::= { oetPortEntry 15 }
oetPortTxState OBJECT-TYPE
SYNTAX INTEGER { na(0), on(1), off(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of Port SFP transmitter."
::= { oetPortEntry 16 }
oetPortTxReach OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Optical reach in meters reported by Port SFP."
::= { oetPortEntry 17 }
oetPortSfpSerialNumber OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port SFP serial number."
::= { oetPortEntry 18 }
-- The elements in the uob subgroup of the configuration group
uobNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of rows in the uob table. This number
is automatically updated whenever a new row is added
to the table below."
::= { uob 1 }
uobTable OBJECT-TYPE
SYNTAX SEQUENCE OF UobEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
UOB card"
::= { uob 2 }
uobEntry OBJECT-TYPE
SYNTAX UobEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { uobCardLocation, uobCardShelf, uobCardSlot }
::= { uobTable 1 }
UobEntry ::=
SEQUENCE
{
uobCardLocation CardLocation,
uobCardShelf CardShelf,
uobCardSlot INTEGER,
uobSerialNum SerialString,
uobModelNum DisplayString,
uobHwName DisplayString,
uobHwVersionID VersionString,
uobMfgDate DateAndTime,
uobFwName CardName,
uobFwVersionID VersionString,
uobFwDate DateAndTime,
uobModelType INTEGER,
uobCfgName CardName,
uobModuleName DisplayString,
uobAdminState INTEGER,
uobSetState INTEGER,
uobCleiNum DisplayString,
uobFpgaRev INTEGER,
uobOperationMode INTEGER,
uobOutPower DisplayString,
uobGain DisplayString,
uobGainTilt DisplayString,
uobLosMode INTEGER,
uobLosThreshold DisplayString,
uobRflThreshold DisplayString
}
uobCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { uobEntry 1 }
uobCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf where the module resides."
::= { uobEntry 2 }
uobCardSlot OBJECT-TYPE
SYNTAX SlotInput
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The slot within the shelf where the module resides.
The range of valid values range from 1 through 17
depending on the chassis type and the shelf where
the module is in. To delete this card, set this
variable to 0."
::= { uobEntry 3 }
uobSerialNum OBJECT-TYPE
SYNTAX SerialString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module serial number."
::= { uobEntry 4 }
uobModelNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module model number."
::= { uobEntry 5 }
uobHwName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware name."
::= { uobEntry 6 }
uobHwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module hardware version."
::= { uobEntry 7 }
uobMfgDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and Time of manufacturing of the module"
::= { uobEntry 8 }
uobFwName OBJECT-TYPE
SYNTAX CardName
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module firmware name."
::= { uobEntry 9 }
uobFwVersionID OBJECT-TYPE
SYNTAX VersionString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware version."
::= { uobEntry 10 }
uobFwDate OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Firmware release date and time."
::= { uobEntry 11 }
uobModelType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Model type of the module."
::= { uobEntry 12 }
uobCfgName OBJECT-TYPE
SYNTAX CardName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name of the module."
::= { uobEntry 13 }
uobModuleName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"name of the module."
::= { uobEntry 14 }
uobAdminState OBJECT-TYPE
SYNTAX INTEGER { disable(1), enable(2), na(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Administrative control for the module. Default
value is enable. When disabled, no alarms/events are
generated for the module."
::= { uobEntry 15}
uobSetState OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Instruct the module to do a warmboot.
A get on this will always return 'other'."
::= { uobEntry 16 }
uobCleiNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CLEI number of the module."
::= { uobEntry 17 }
uobFpgaRev OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA revision for the module."
::= { uobEntry 18 }
uobOperationMode OBJECT-TYPE
SYNTAX INTEGER {
invalid(0),
constainPower(1),
constantGain(2),
disabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Invalid, Constain Power, Constant Gain, Disabled.
Constain Power(1) is not valid on Fixed modules."
::= { uobEntry 19 }
uobOutPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
" uobModuleName - Configured Power in dBm
T17VO - range: -13.0 to 17.5
T17VR - range: -13.0 to 17.5
T20FR - range: -7.0 to 20.10
T15FR - range: -7.0 to 15.10 "
::= { uobEntry 20 }
uobGain OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
" uobModuleName - Configured Gain in dB
T17VO - range: 10.0 to 20.0
T17VR - range: 10.0 to 20.0
T20FR - range: 16.0 to 28.0 default:22
T15FR - range: 16.0 to 28.0 default:22"
::= { uobEntry 21 }
uobGainTilt OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
" uobModuleName - Configured Gain Tilt in dB
T17VO - range: -2.0 to 2.0
T17VR - range: -2.0 to 2.0 "
::= { uobEntry 22 }
uobLosMode OBJECT-TYPE
SYNTAX INTEGER {
noEffect(1),
disabledInAll(2),
disabledInPower(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
" No effect, Disabled in all modes,
Disabled in Power Mode only"
::= { uobEntry 23 }
uobLosThreshold OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
" uobModuleName - Configured Los Threshold in dBm
T17VO - range: -100.0 to 45.0 default: -31
T17VR - range: -100.0 to 45.0 default: -31
T20FR - range: -40.0 to -5.0 default: -35
T15FR - range: -40.0 to -5.0 default: -35"
::= { uobEntry 24 }
uobRflThreshold OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
" uobModuleName - Configured Rfl Threshold in dB
T17VO - range: 0.0 to 50.0
T17VR - range: -23.0 to -14.0
T20FR - range: -23.0 to -14.0
T15FR - range: -23.0 to -14.0 "
::= { uobEntry 25 }
-- The elements in the uobPerf subgroup of the current subgroup
uobNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
UOB modules in this time slot (15 minutes)."
::= { uobPerf 1 }
uobPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF UobPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each UOB module."
::= { uobPerf 2 }
uobPerfEntry OBJECT-TYPE
SYNTAX UobPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { uobPerfLocation, uobPerfShelf, uobPerfSlot }
::= { uobPerfTable 1 }
UobPerfEntry ::=
SEQUENCE
{
uobPerfLocation CardLocation,
uobPerfShelf CardShelf,
uobPerfSlot INTEGER,
uobPerfState CardState,
uobPerfStatus CardStatus,
uobLastBootTime DateAndTime,
uobAvailTime Counter,
uobErrFreeSecs Counter
}
uobPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { uobPerfEntry 1 }
uobPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { uobPerfEntry 2 }
uobPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { uobPerfEntry 3 }
uobPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the UOB module. The states are:
online = 2 and offline = 3"
::= { uobPerfEntry 4 }
uobPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This status represents the status of the UOB module
and in general is different from the status of
the system."
::= { uobPerfEntry 5 }
uobLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { uobPerfEntry 6 }
uobAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { uobPerfEntry 7 }
uobErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { uobPerfEntry 8 }
uobPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF UobPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { uobPerf 3 }
uobPmEntry OBJECT-TYPE
SYNTAX UobPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { uobPmLocation, uobPmShelf, uobPmSlot }
::= { uobPmTable 1 }
UobPmEntry ::=
SEQUENCE
{
uobPmLocation CardLocation,
uobPmShelf CardShelf,
uobPmSlot INTEGER,
uobPmSystemStatus DisplayString,
uobPmPumpCurrent DisplayString,
uobPmPumpTemp DisplayString,
uobPmInputPower DisplayString,
uobPmOutPower DisplayString,
uobPmTotalGain DisplayString,
uobPmReflection DisplayString
}
uobPmLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the UOB card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
UOB cards."
::= { uobPmEntry 1 }
uobPmShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) UOB
cards."
::= { uobPmEntry 2 }
uobPmSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) UOB cards."
::= { uobPmEntry 3 }
uobPmSystemStatus OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System Status"
::= { uobPmEntry 4 }
uobPmPumpCurrent OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pump Current in mA"
::= { uobPmEntry 5 }
uobPmPumpTemp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pump temp in C"
::= { uobPmEntry 6 }
uobPmInputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Input pwr in dBm"
::= { uobPmEntry 7 }
uobPmOutPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Output pwr in dBm"
::= { uobPmEntry 8 }
uobPmTotalGain OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total gain in dB"
::= { uobPmEntry 9 }
uobPmReflection OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reflection in dB"
::= { uobPmEntry 10 }
-- The elements in the uobHist subgroup of the historical subgroup
uobHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF UobHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the UOB module."
::= { uobHist 1 }
uobHistEntry OBJECT-TYPE
SYNTAX UobHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { uobHMode }
::= { uobHistTable 1 }
UobHistEntry ::=
SEQUENCE
{
uobHMode HistoryMode,
uobHNumEvents Counter
}
uobHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { uobHistEntry 1 }
uobHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
UOB modules."
::= { uobHistEntry 2 }
uobHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF UobHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each UOB module"
::= { uobHist 2 }
uobHHistEntry OBJECT-TYPE
SYNTAX UobHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { uobHHistMode, uobHHistLocation, uobHHistShelf,
uobHHistSlot }
::= { uobHHistTable 1 }
UobHHistEntry ::=
SEQUENCE
{
uobHHistMode HistoryMode,
uobHHistLocation CardLocation,
uobHHistShelf CardShelf,
uobHHistSlot INTEGER,
uobHLastBootTime DateAndTime,
uobHAvailTime Counter,
uobHErrFreeSecs Counter
}
uobHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { uobHHistEntry 1 }
uobHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { uobHHistEntry 2 }
uobHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { uobHHistEntry 3 }
uobHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { uobHHistEntry 4 }
uobHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { uobHHistEntry 5 }
uobHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has been up and
running."
::= { uobHHistEntry 6 }
uobHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has not
experienced any alarms."
::= { uobHHistEntry 7 }
-- The elements in the fc8gPerf subgroup of the current subgroup
fc8gNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
FC8G modules in this time slot (15 minutes)."
::= { fc8gPerf 1 }
fc8gPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Fc8gPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each FC8G module."
::= { fc8gPerf 2 }
fc8gPerfEntry OBJECT-TYPE
SYNTAX Fc8gPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fc8gPerfLocation, fc8gPerfShelf, fc8gPerfSlot }
::= { fc8gPerfTable 1 }
Fc8gPerfEntry ::=
SEQUENCE
{
fc8gPerfLocation CardLocation,
fc8gPerfShelf CardShelf,
fc8gPerfSlot INTEGER,
fc8gPerfState CardState,
fc8gPerfStatus CardStatus,
fc8gLastBootTime DateAndTime,
fc8gAvailTime Counter,
fc8gErrFreeSecs Counter
}
fc8gPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { fc8gPerfEntry 1 }
fc8gPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { fc8gPerfEntry 2 }
fc8gPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { fc8gPerfEntry 3 }
fc8gPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the FC8G module. The states are:
online, offline, empty or loopback."
::= { fc8gPerfEntry 4 }
fc8gPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the FC8G module. This status represents
the status of the FC8G module and in general is
different from the status of the system."
::= { fc8gPerfEntry 5 }
fc8gLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { fc8gPerfEntry 6 }
fc8gAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { fc8gPerfEntry 7 }
fc8gErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { fc8gPerfEntry 8 }
-- Miscellaneous configuration elements
sysAddCard OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add card operation given type, shelf, slot, and
optionally sub card type. The format is (type,shelf,
slot[,optional]). If the fourth optional
parameter is present, for OCMITU/OCMU, its value should
be 1 to indicate OCMITU/OCMU with CSIM; for MCMESC, its
value should be 0 or 1 to indicate MPM will not overide or
will override the settings stored on MCMESC upon detecting
it.
Different types of card:
OCMU: 2 //with or without csim module
OCMI: 3 //with or without csim module
OFCM: 4
OFCD: 5
FADM: 6
MCMT1: 8
W4CD: 10
W2CM/D: 13
OSAM: 20
W4CM: 21
RSM: 22
UPSM: 23
OCME: 24
OCM10G: 27
OSAM-LP: 29
OSAM-HP: 30
MCMESC: 33
WFADM: 34
MCME1: 35
MD100-1: 36
MD100-40: 37
TAP: 38
MD100-5 39
MD100-10 40
OCM10GLR 41
BD-4 42
BP-10 43
DMM 45
BP-5 46
OSC 48
OCM2 49
OCM10GF 50
OCM2-4G 51
OET 52
UOB 53
FC8G 54
MD100P 55
CWDM_BD4 56
For example, to add a FADM card in shelf 1, slot 8,
this variable will be set to 6,1,8.
To add an OCMI card with colorsim module in shelf 1,
slot 7, this variable will be set to 3,1,7,1.
To add an MCMESC card with override option in shelf 1,
slot 7, this variable will be set to 33,1,7,1.
A get on this will return 0,0,0,0"
::= { systemConfig 1 }
sysAlarmCtrl OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Master Control for Alarms. Will enable or disable
all external and visual alarms of the system. The
default state is enable."
::= { systemConfig 2 }
sysAlarmCritical OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turns on or off all external critical audible
and visual alarms."
::= { systemConfig 3 }
sysAlarmMajor OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turns on or off all external major and minor
audible and visual alarms."
::= { systemConfig 4 }
sysAlarmSerial OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or disables the flow of TL1 alarms to the
serial port."
::= { systemConfig 5 }
sysAlarmAutoCutoff OBJECT-TYPE
SYNTAX INTEGER { enable(1), disable(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or disables the AutoCutoff feature
for dry-contact alarm closures"
::= { systemConfig 6 }
sysAddRoute OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Add route operation given local shelf, local slot, destination
IP address and route Type. The format is (shelf, slot,
route Type, destination IP).
Different types of route types are:
external Route: 1 (Route to an external non LuxN node)
internal Route: 2 (Route to a LuxN node in the network)
For example, to add an internal route to a LuxN node with IP address
192.162.6.65 from local shelf 1, slot 6 this variable would
be set to 1,6,3,192.162.6.65
For adding an external route, shelf & slot needs to be zero. For e.g
To add an external route to destination address 192.168.9.99,
this variable needs to be set to 0,0,192.168.9.99
A get on this will return 0,0,0,0
NO LONGER SUPPORTED, user now needs to use sysImnAddRoute"
::= { systemConfig 7 }
sysDeleteRoute OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Delete route operation given local shelf, local slot & destination
IP address . The format is (shelf, slot,
destination IP).
For example, to delete a route to a LuxN node with IP address
192.162.6.65 from local shelf 1, slot 6 this variable would
be set to 1,6,192.162.6.65
A get on this will return 0,0,0
NO LONGER SUPPORTED, user now needs to use sysImnAddRoute"
::= { systemConfig 8 }
sysSwitchByPathId OBJECT-TYPE
SYNTAX PathIdName
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Initiate UPSR switching by Path ID."
::= { systemConfig 9 }
sysSwitchAll OBJECT-TYPE
SYNTAX INTEGER { yes(1), no(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Switch all CC cards that have backup."
::= { systemConfig 10 }
sysAlarmMinor OBJECT-TYPE
SYNTAX INTEGER { on(1), off(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turns on or off all external minor
audible and visual alarms."
::= { systemConfig 11 }
sysDelCfgDb OBJECT-TYPE
SYNTAX INTEGER { other(1), delete(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Action to delete configuration database. MPM would reboot
after the database is deleted. A get on it will return other"
::= { systemConfig 12 }
sysImnAddRoute OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add route operation. It takes destination IP address,
IP mask and the route metric.
The format is (destination IP, IP mask, routeMetric).
A get on this will return 0.0.0.0,0.0.0.0,0"
::= { systemConfig 13 }
sysImnDeleteRoute OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete route operation. It takes destination IP address
and IP mask.
The format is (destination IP, IP mask=).
A get on this will return 0.0.0.0,0.0.0.0"
::= { systemConfig 14 }
sysExtAlarmInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysExtAlarmInputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the input information for each
external alarm indicator"
::= { systemConfig 17 }
sysExtAlarmInputEntry OBJECT-TYPE
SYNTAX SysExtAlarmInputEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { sysExtAlarmInputId }
::= { sysExtAlarmInputTable 1 }
SysExtAlarmInputEntry ::=
SEQUENCE
{
sysExtAlarmInputId INTEGER,
sysExtAlarmInput INTEGER,
sysExtAlarmInputName AlarmType
}
sysExtAlarmInputId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Id of an external alarm indicator. Valid
values are: 1 to 6"
::= { sysExtAlarmInputEntry 1 }
sysExtAlarmInput OBJECT-TYPE
SYNTAX INTEGER { off(1), minor(2), major(3), critical(4), na(5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Configurable value for an external alarm indicator.
Default value is off. For the chassis with old sensor board,
the value is na and is not settable."
::= { sysExtAlarmInputEntry 2 }
sysExtAlarmInputName OBJECT-TYPE
SYNTAX AlarmType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User configurable name for an external alarm input indicator.
For the chassis with old sensor board, the value is na
and is not settable."
::= { sysExtAlarmInputEntry 3 }
sysAudioAlarm OBJECT-TYPE
SYNTAX INTEGER { brief(1), test(2), continous(3), off(4), na(5) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Mode for audio alarm.
Default is off. For non-carrier-class chassis, it is na"
::= { systemConfig 18 }
sysAudioAlarmSeverity OBJECT-TYPE
SYNTAX INTEGER { major(1), critical(2), minor(3), na(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls for audio alarm. When the control is set to
minor, it will go off for all minor and up
alarms. Default is major. For non-carrier-class chassis,
it is na. These control only make sense for
audio alarm in brief or continous mode"
::= { systemConfig 19 }
sysRdbcopy OBJECT-TYPE
SYNTAX INTEGER { other(1), copydb(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Forces a database copy to the standby MPM. Reading this
element will always return 'other'. This element can
only be set to 'copydb'. If the standby MPM is present
then a database copy will be initiated, otherwise an
error will be return."
::= { systemConfig 20 }
sysRdbcopyStatus OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the percentage done for forced database copies.
No value is returned if a forced database copy is not
in progress."
::= { systemConfig 21 }
sysSDMRequestsQueued OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the number of requests in the SDM queue."
::= { systemConfig 22 }
sysModuleupdateJobsWaiting OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the number of module updates jobs from the
current request that must wait until one or more of
the jobs progressing completes. This element will
only be returned if one or more module update jobs
are in progress."
::= { systemConfig 23 }
sysModuleupdateJobsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysModuleupdateJobsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table defines the module update jobs in progress.
Table entries will only be reutrned if one for more
module update jobs are in progress."
::= { systemConfig 24 }
sysModuleupdateJobsEntry OBJECT-TYPE
SYNTAX SysModuleupdateJobsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { sysModupdShelf, sysModupdSlot, sysModupdLocation, sysModupdRmtStation }
::= { sysModuleupdateJobsTable 1 }
SysModuleupdateJobsEntry ::=
SEQUENCE
{
sysModupdShelf INTEGER,
sysModupdSlot INTEGER,
sysModupdLocation CardLocation,
sysModupdRmtStation INTEGER,
sysModupdCardtype CardType,
sysModupdPercentDone INTEGER
}
sysModupdShelf OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Shelf of the module being updated. For remote updates
this will be the shelf of the local module through the
update occurs."
::= { sysModuleupdateJobsEntry 1 }
sysModupdSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot of the module being updated. For remote updates
this will be the slot of the local module through the
update occurs."
::= { sysModuleupdateJobsEntry 2 }
sysModupdLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location (local or remote) of the module being updated"
::= { sysModuleupdateJobsEntry 3 }
sysModupdRmtStation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote station of the module being updated"
::= { sysModuleupdateJobsEntry 4 }
sysModupdCardtype OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Type of module being updated."
::= { sysModuleupdateJobsEntry 5 }
sysModupdPercentDone OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Percentage of update completed."
::= { sysModuleupdateJobsEntry 6 }
sysSNMPKeepaliveEnable OBJECT-TYPE
SYNTAX INTEGER {enabled(1), disabled(2)}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable SNMP keep alive functionality."
::= { systemConfig 25 }
sysSNMPKeepaliveInterval OBJECT-TYPE
SYNTAX INTEGER (1..1440)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set the SNMP keep alive interval in minutes."
::= { systemConfig 26 }
-- The elements in the systemPerf subgroup of the current subgroup
sysStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The global status of the system as computed based on
the traps (events) that are generated. Choices are:
Critical, Major, Minor or Normal."
::= { systemPerf 1 }
sysClearStatus OBJECT-TYPE
SYNTAX ResetType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Reset the system state to Normal. The value of reset
means set the state to Normal. A get on this will
always return other.
Note: This element is now made not-accessible as sysStatus
is now a read-only element"
::= { systemPerf 2 }
sysClearCounters OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset all performance counters in this 15 minutes time
interval to zero. The value of reset means to reset the
counters to zero. A get on this will always return
other."
::= { systemPerf 3 }
sysLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last system boot. This time
represents the boot time of a CP card. It is also
anonymous with the power-up cycle of the chassis."
::= { systemPerf 4 }
sysAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that the system has been up and running. This will
generally be the same as 15 minutes in seconds (900),
but, if the system has been reboot in the last 15
minutes interval, then it represents the number of
seconds the system has been up. The criteria for the
system available time is having at least one CP
running with atmost non-service affecting minor
alarm system status"
::= { systemPerf 5 }
sysErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that the device has not experienced any alarms. This
counter is across all cards in the chassis. The
system must be in Normal status for this counter to
be incremented."
::= { systemPerf 6 }
sysExhaustTemperature OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Temperature of the Chassis. Units of dgree centigrade."
::= { systemPerf 7 }
-- The elements in the downloadPerf subgroup of the current subgroup
dlStatus OBJECT-TYPE
SYNTAX DownloadStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The global status of the download task. The download task
(download to the device) is either ftp_inprogress, module
update inprogrss or currently idle. Since only one download
at the time is handled by the system, this flag is set to
inprogress as soon as any download starts.
It is reset back to idle when the download is completed.
This flag is set to idle on system startup. This flag
can be remotely set to idle if a previous FTP download
was interrupted."
::= { downloadPerf 1 }
dlOkDownloads OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of successful downloads in this time
interval (15 minutes)."
::= { downloadPerf 2 }
dlBadDownloads OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of failed downloads in this time
interval (15 minutes)."
::= { downloadPerf 3 }
dlLongestTime OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Longest time for any download, in seconds, in this
time interval (15 minutes)."
::= { downloadPerf 4 }
dlLongestSize OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Longest download size for any download, in bytes, in
this time interval (15 minutes)."
::= { downloadPerf 5 }
-- The elements in the cpPerf subgroup of the current subgroup
cpNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received by the active CP in
this time slot (15 minutes)."
::= { cpPerf 1 }
cpTrapsSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of traps sent by the active CP in
this time slot (15 minutes)."
::= { cpPerf 2 }
cpSNMPCmdsRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of SNMP commands received by the active
CP in this time slot (15 minutes)."
::= { cpPerf 3 }
cpCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turns software counters On or Off."
::= { cpPerf 4 }
cpCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry of the software counters. It is only
applicable to the active MPM card."
::= { cpPerf 5 }
cpCntrEntry OBJECT-TYPE
SYNTAX CpCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpCntrShelf, cpCntrSlot, cpCntrType }
::= { cpCntrTable 1 }
CpCntrEntry ::=
SEQUENCE
{
cpCntrShelf CardShelf,
cpCntrSlot INTEGER,
cpCntrType INTEGER,
cpTotPktSent Counter,
cpTotPktRcvd Counter,
cpBadPktRcvd Counter,
cpTotBadTrans Counter,
cpBytesSent Counter,
cpBytesRcvd Counter,
cpMsgsDlvrd Counter,
cpBufAllocFail Counter,
cpEcbAllocFail Counter,
cpClearCntrs ResetType
}
cpCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the value of the current
active CP card."
::= { cpCntrEntry 1 }
cpCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 2. The system automatically
determines the right value for this entry based
on the value of the current active CP card."
::= { cpCntrEntry 2 }
cpCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { cpCntrEntry 3 }
cpTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { cpCntrEntry 4 }
cpTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { cpCntrEntry 5 }
cpBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { cpCntrEntry 6 }
cpTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { cpCntrEntry 7 }
cpBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { cpCntrEntry 8 }
cpBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { cpCntrEntry 9 }
cpMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { cpCntrEntry 10 }
cpBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { cpCntrEntry 11 }
cpEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { cpCntrEntry 12 }
cpClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other"
::= { cpCntrEntry 13 }
cpPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each communication processor"
::= { cpPerf 6 }
cpPerfEntry OBJECT-TYPE
SYNTAX CpPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpPerfShelf, cpPerfSlot }
::= { cpPerfTable 1 }
CpPerfEntry ::=
SEQUENCE
{
cpPerfShelf CardShelf,
cpPerfSlot INTEGER,
cpPerfMode RedundancyMode,
cpPerfState CardState,
cpPerfStatus CardStatus,
cpLastBootTime DateAndTime,
cpAvailTime Counter,
cpErrFreeSecs Counter
}
cpPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2"
::= { cpPerfEntry 1 }
cpPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 3"
::= { cpPerfEntry 2 }
cpPerfMode OBJECT-TYPE
SYNTAX RedundancyMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The valid types are: active CP or standby CP"
::= { cpPerfEntry 3 }
cpPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the communication card. The status'
are: online, offline, empty, loopback or diagnostics."
::= { cpPerfEntry 4 }
cpPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the communication processor. This
status represents the state of the communication
processor and in general is different from the
status of the system."
::= { cpPerfEntry 5 }
cpLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this CP."
::= { cpPerfEntry 6 }
cpAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this CP has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { cpPerfEntry 7 }
cpErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this CP has not experienced any alarms."
::= { cpPerfEntry 8 }
-- The elements in the ccPerf subgroup of the current subgroup
ccNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received for all CC's in
this time slot (15 minutes)."
::= { ccPerf 1 }
ccCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ccPerf 2 }
ccCntrEntry OBJECT-TYPE
SYNTAX CcCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccCntrLocation, ccCntrShelf, ccCntrSlot, ccCntrType }
::= { ccCntrTable 1 }
CcCntrEntry ::=
SEQUENCE
{
ccCntrLocation CardLocation,
ccCntrShelf CardShelf,
ccCntrSlot INTEGER,
ccCntrType INTEGER,
ccCounterFlag FlagType,
ccTotPktSent Counter,
ccTotPktRcvd Counter,
ccBadPktRcvd Counter,
ccTotBadTrans Counter,
ccBytesSent Counter,
ccBytesRcvd Counter,
ccMsgsDlvrd Counter,
ccBufAllocFail Counter,
ccEcbAllocFail Counter,
ccClearCntrs ResetType
}
ccCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the CC card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
CC cards."
::= { ccCntrEntry 1 }
ccCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) CC
cards."
::= { ccCntrEntry 2 }
ccCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) CC cards."
::= { ccCntrEntry 3 }
ccCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), iwm(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { ccCntrEntry 4 }
ccCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turns software counters, both On or both Off for this CC.
When set to Off, both counters statistic information will
be cleared."
::= { ccCntrEntry 5 }
ccTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { ccCntrEntry 6 }
ccTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { ccCntrEntry 7 }
ccBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { ccCntrEntry 8 }
ccTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { ccCntrEntry 9 }
ccBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { ccCntrEntry 10 }
ccBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { ccCntrEntry 11 }
ccMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { ccCntrEntry 12 }
ccBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { ccCntrEntry 13 }
ccEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { ccCntrEntry 14 }
ccClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other"
::= { ccCntrEntry 15 }
ccPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each channel card"
::= { ccPerf 3 }
ccPerfEntry OBJECT-TYPE
SYNTAX CcPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccPerfLocation, ccPerfShelf, ccPerfSlot }
::= { ccPerfTable 1 }
CcPerfEntry ::=
SEQUENCE
{
ccPerfLocation CardLocation,
ccPerfShelf CardShelf,
ccPerfSlot INTEGER,
ccPerfState CardState,
ccPerfStatus CardStatus,
ccLastBootTime DateAndTime,
ccAvailTime Counter,
ccErrFreeSecs Counter,
ccBiasCurrent INTEGER,
ccModulation INTEGER,
ccApc INTEGER,
ccIwmModulation INTEGER,
ccLaserOnOff FlagType,
ccTemperature Gauge,
ccIntensity Gauge,
ccSignalStrength Gauge,
ccLossOfLight Boolean,
ccSignalDetect Boolean,
ccRefClock INTEGER,
ccClockDiv INTEGER,
ccLinkTxPwrStatus INTEGER,
ccLinkRxSigStrStatus INTEGER,
ccCpeRxSigDetect INTEGER,
ccLinkIWMStatus INTEGER,
ccLinkSummaryStatus INTEGER,
ccProtectionMode INTEGER,
ccLinkRxSigStr DisplayString
}
ccPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card. Valid choices are Local
or Remote. The system automatically selects this
value based on the known (available) CC cards."
::= { ccPerfEntry 1 }
ccPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { ccPerfEntry 2 }
ccPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 4 to 42"
::= { ccPerfEntry 3 }
ccPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the channel card. The states'
are: online, offline, empty, loopback or diagnostics."
::= { ccPerfEntry 4 }
ccPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the channel card. This
status represents the status of the communication
processor and in general is different from the
status of the system."
::= { ccPerfEntry 5 }
ccLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { ccPerfEntry 6 }
ccAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this CC has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { ccPerfEntry 7 }
ccErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this CC has not experienced any alarms."
::= { ccPerfEntry 8 }
ccBiasCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bias current for the optical laser."
::= { ccPerfEntry 9 }
ccModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency modulation for the optical laser."
::= { ccPerfEntry 10 }
ccApc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The APC value."
::= { ccPerfEntry 11 }
ccIwmModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency modulation for the IWM channel."
::= { ccPerfEntry 12 }
ccLaserOnOff OBJECT-TYPE
SYNTAX FlagType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The laser On/Off flag."
::= { ccPerfEntry 13 }
ccTemperature OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current temperature, or the operating temperature
of the optical device."
::= { ccPerfEntry 14 }
ccIntensity OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The intensity of the optical light."
::= { ccPerfEntry 15 }
ccSignalStrength OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current signal strength for the optical path."
::= { ccPerfEntry 16 }
ccLossOfLight OBJECT-TYPE
SYNTAX Boolean
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If set to true, no laser light is present. If set to
false, no loss of light has occurred."
::= { ccPerfEntry 17 }
ccSignalDetect OBJECT-TYPE
SYNTAX Boolean
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If set to true, signal is detected. If set to false,
no signal is present. Replaced with ccCpeRxSigDetect"
::= { ccPerfEntry 18 }
ccRefClock OBJECT-TYPE
SYNTAX INTEGER { en1660(1), en1944(2), en1953(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The value of the reference clock in decimal notation.
For a given value, like 1660, the actual value is
16.60-EN. In otherwords, assume a two digit decimal
point, plus any appropriate scaling factor."
::= { ccPerfEntry 19 }
ccClockDiv OBJECT-TYPE
SYNTAX INTEGER { dout-1250(1), dout-622(2), dout-155(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The clock divisor. Values are 1250, 622 or 155 in the
appropriate clock frequency scale."
::= { ccPerfEntry 20 }
ccLinkTxPwrStatus OBJECT-TYPE
SYNTAX INTEGER { ok(1), fault(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This indicates whether the link transmit power is within the
normal range of operation."
::= { ccPerfEntry 21 }
ccLinkRxSigStrStatus OBJECT-TYPE
SYNTAX INTEGER { ok(1), fault(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This indicates whether the link's receive signal is within the
normal range of operation."
::= { ccPerfEntry 22 }
ccCpeRxSigDetect OBJECT-TYPE
SYNTAX INTEGER { yes(1), no(2)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This indicates whether there is presence of CPE receive signal"
::= { ccPerfEntry 23 }
ccLinkIWMStatus OBJECT-TYPE
SYNTAX INTEGER { ok(1), error(2), notApplicable(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This indicates the current status of IWM. This value is only
applicable to remote OCMs"
::= { ccPerfEntry 24 }
ccLinkSummaryStatus OBJECT-TYPE
SYNTAX INTEGER { ok(1), fault(2), notApplicable(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the result of a logical and operation of all the individual
link status. If any of the attributes is N/A, except for the local
local IWM status, this value is N/A"
::= { ccPerfEntry 25 }
ccProtectionMode OBJECT-TYPE
SYNTAX INTEGER { working(1), protection(2), na(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"UPSR Protection Mode: active, standby and n/a."
::= { ccPerfEntry 26 }
ccLinkRxSigStr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link's received signal strength in dBm."
::= { ccPerfEntry 27 }
-- The elements in the muxPerf subgroup of the current subgroup
muxNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
MUX's in this time slot (15 minutes)."
::= { muxPerf 1 }
muxPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each mux/demux card"
::= { muxPerf 2 }
muxPerfEntry OBJECT-TYPE
SYNTAX MuxPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { muxPerfLocation, muxPerfShelf, muxPerfSlot }
::= { muxPerfTable 1 }
MuxPerfEntry ::=
SEQUENCE
{
muxPerfLocation CardLocation,
muxPerfShelf CardShelf,
muxPerfSlot INTEGER,
muxType INTEGER,
muxPerfState CardState,
muxPerfStatus CardStatus,
muxLastBootTime DateAndTime,
muxAvailTime Counter,
muxErrFreeSecs Counter
}
muxPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { muxPerfEntry 1 }
muxPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { muxPerfEntry 2 }
muxPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 42"
::= { muxPerfEntry 3 }
muxType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the mux. The choices are: mux or demux."
::= { muxPerfEntry 4 }
muxPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the mux card. The states are:
online, offline, empty, loopback or diag."
::= { muxPerfEntry 5 }
muxPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the mux card. This status represents
the status of the mux card and in general is
different from the status of the system."
::= { muxPerfEntry 6 }
muxLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { muxPerfEntry 7 }
muxAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this Mux has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { muxPerfEntry 8 }
muxErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this mux has not experienced any alarms."
::= { muxPerfEntry 9 }
-- The elements in the psPerf subgroup of the current subgroup
psNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
Power Supplies in this time slot (15 minutes)."
::= { psPerf 1 }
psVoltageLevel3pt4Volt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Voltage Level of the 3.4 V power supply."
::= { psPerf 2 }
psVoltageLevel5pt1Volt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Voltage Level of the 5.1 V power supply."
::= { psPerf 3 }
psVoltageLevel12Volt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Voltage Level of the 12 V power supply."
::= { psPerf 4 }
psPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PsPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each power supply card"
::= { psPerf 5 }
psPerfEntry OBJECT-TYPE
SYNTAX PsPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { psPerfID }
::= { psPerfTable 1 }
PsPerfEntry ::=
SEQUENCE
{
psPerfID INTEGER,
psPerfType INTEGER,
psPerfState INTEGER,
psPerfStatus CardStatus
}
psPerfID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module ID where the PS is plugged in."
::= { psPerfEntry 1 }
psPerfType OBJECT-TYPE
SYNTAX INTEGER { psDC(1), psAC(2), unknown(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the power supply."
::= { psPerfEntry 2 }
psPerfState OBJECT-TYPE
SYNTAX INTEGER { psEmpty(1), psOK(2), psFailed(3), psDegrade(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the power supply module."
::= { psPerfEntry 3 }
psPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the power supply module. This status
represents the status of the ps module and in general is
different from the status of the system."
::= { psPerfEntry 4 }
psVoltageLevelFeedA OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Voltage Level of the -48 VDC input from Feed A."
::= { psPerf 6 }
psVoltageLevelFeedB OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Voltage Level of the -48 VDC input from Feed B."
::= { psPerf 7 }
psBreakerConditionFeedA OBJECT-TYPE
SYNTAX INTEGER { open(1), closed(2), na(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of Feed A breaker."
::= { psPerf 8 }
psPerfStatusFeedA OBJECT-TYPE
SYNTAX INTEGER { feedOK(1), feedFAILED(2), feedUNKNOWN(3), na(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of Feed A breaker. Failed if it
goes into shutdown condition
Unknown if the corresponding breaker
is open"
::= { psPerf 9 }
psBreakerConditionFeedB OBJECT-TYPE
SYNTAX INTEGER { open(1), closed(2), na(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of Feed B breaker."
::= { psPerf 10 }
psPerfStatusFeedB OBJECT-TYPE
SYNTAX INTEGER { feedOK(1), feedFAILED(2), feedUNKNOWN(3), na(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"State of Feed B.
Failed if it goes into shutdown condition
Unknown if the corresponding breaker is open"
::= { psPerf 11 }
-- The elements in the fadmPerf subgroup of the current subgroup
fadmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
MUX's in this time slot (15 minutes)."
::= { fadmPerf 1 }
fadmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FadmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each fadm card"
::= { fadmPerf 2 }
fadmPerfEntry OBJECT-TYPE
SYNTAX FadmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fadmPerfLocation, fadmPerfShelf, fadmPerfSlot }
::= { fadmPerfTable 1 }
FadmPerfEntry ::=
SEQUENCE
{
fadmPerfLocation CardLocation,
fadmPerfShelf CardShelf,
fadmPerfSlot INTEGER,
fadmPerfState CardState,
fadmPerfStatus CardStatus,
fadmLastBootTime DateAndTime,
fadmAvailTime Counter,
fadmErrFreeSecs Counter
}
fadmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { fadmPerfEntry 1 }
fadmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { fadmPerfEntry 2 }
fadmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 42"
::= { fadmPerfEntry 3 }
fadmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the fadm card. The states are:
online, offline, empty, loopback or diag."
::= { fadmPerfEntry 4 }
fadmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the fadm card. This status represents
the status of the fadm card and in general is
different from the status of the system."
::= { fadmPerfEntry 5 }
fadmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { fadmPerfEntry 6 }
fadmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this fadm card has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { fadmPerfEntry 7 }
fadmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this fadm card has not experienced any alarms."
::= { fadmPerfEntry 8 }
-- The elements in the oppmPerf subgroup of the current subgroup
oppmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OPPM's in this time slot (15 minutes)."
::= { oppmPerf 1 }
oppmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OppmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each oppm card"
::= { oppmPerf 2 }
oppmPerfEntry OBJECT-TYPE
SYNTAX OppmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oppmPerfLocation, oppmPerfShelf, oppmPerfSlot }
::= { oppmPerfTable 1 }
OppmPerfEntry ::=
SEQUENCE
{
oppmPerfLocation CardLocation,
oppmPerfShelf CardShelf,
oppmPerfSlot INTEGER,
oppmPerfState CardState,
oppmPerfStatus CardStatus,
oppmLinkAState INTEGER,
oppmLinkAStatus INTEGER,
oppmLinkBState INTEGER,
oppmLinkBStatus INTEGER,
oppmLastBootTime DateAndTime,
oppmAvailTime Counter,
oppmErrFreeSecs Counter,
oppmWorkingPower INTEGER,
oppmProtectPower INTEGER
}
oppmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or remote."
::= { oppmPerfEntry 1 }
oppmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { oppmPerfEntry 2 }
oppmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 4 to 42"
::= { oppmPerfEntry 3 }
oppmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the oppm card. The states are:
online, offline."
::= { oppmPerfEntry 4 }
oppmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the oppm card. This status represents
the status of the oppm card and in general is
different from the status of the system."
::= { oppmPerfEntry 5 }
oppmLinkAState OBJECT-TYPE
SYNTAX INTEGER { linked(1), notLinked(2), unknown(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the oppm card. The states are:
linked, notLinked."
::= { oppmPerfEntry 6 }
oppmLinkAStatus OBJECT-TYPE
SYNTAX INTEGER { active(1), standby(2), hibernation(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link A of the card and in general is
different from the status of the card."
::= { oppmPerfEntry 7 }
oppmLinkBState OBJECT-TYPE
SYNTAX INTEGER { linked(1), notLinked(2), unknown(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the oppm card link B. The states are:
linked, notLinked."
::= { oppmPerfEntry 8 }
oppmLinkBStatus OBJECT-TYPE
SYNTAX INTEGER { active(1), standby(2), hibernation(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link B of the card and in general is
different from the status of the card."
::= { oppmPerfEntry 9 }
oppmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { oppmPerfEntry 10 }
oppmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this oppm card has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { oppmPerfEntry 11 }
oppmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this oppm card has not experienced any alarms."
::= { oppmPerfEntry 12 }
oppmWorkingPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"working power displayed in dBm unit"
::= { oppmPerfEntry 13 }
oppmProtectPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"protect power displayed in dBm unit"
::= { oppmPerfEntry 14 }
-- The elements in the mcmPerf subgroup of the current subgroup
mcmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received for all mcmt1's/mcme1's in
this time slot (15 minutes)."
::= { mcmPerf 1 }
mcmCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { mcmPerf 2 }
mcmCntrEntry OBJECT-TYPE
SYNTAX McmCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmCntrLocation, mcmCntrShelf, mcmCntrSlot, mcmCntrType }
::= { mcmCntrTable 1 }
McmCntrEntry ::=
SEQUENCE
{
mcmCntrLocation CardLocation,
mcmCntrShelf CardShelf,
mcmCntrSlot INTEGER,
mcmCntrType INTEGER,
mcmCounterFlag FlagType,
mcmTotPktSent Counter,
mcmTotPktRcvd Counter,
mcmBadPktRcvd Counter,
mcmTotBadTrans Counter,
mcmBytesSent Counter,
mcmBytesRcvd Counter,
mcmMsgsDlvrd Counter,
mcmBufAllocFail Counter,
mcmEcbAllocFail Counter,
mcmClearCntrs ResetType
}
mcmCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the mcmt1/mcme1 card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
mcmt1/mcme1 cards."
::= { mcmCntrEntry 1 }
mcmCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 3.
The system automatically determines the right value
for this entry based on the known (available) mcmt1/mcme1
cards."
::= { mcmCntrEntry 2 }
mcmCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 21. The system automatically
determines the right value for this entry based
on the known (available) mcmt1/mcme1 cards."
::= { mcmCntrEntry 3 }
mcmCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), iwm(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { mcmCntrEntry 4 }
mcmCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turns software counters On or Off for this mcmt1/mcme1."
::= { mcmCntrEntry 5 }
mcmTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { mcmCntrEntry 6 }
mcmTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { mcmCntrEntry 7 }
mcmBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { mcmCntrEntry 8 }
mcmTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { mcmCntrEntry 9 }
mcmBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { mcmCntrEntry 10 }
mcmBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { mcmCntrEntry 11 }
mcmMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { mcmCntrEntry 12 }
mcmBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { mcmCntrEntry 13 }
mcmEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { mcmCntrEntry 14 }
mcmClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other"
::= { mcmCntrEntry 15 }
mcmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each mcmt1/mcme1 card"
::= { mcmPerf 3 }
mcmPerfEntry OBJECT-TYPE
SYNTAX McmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmPerfLocation, mcmPerfShelf, mcmPerfSlot }
::= { mcmPerfTable 1 }
McmPerfEntry ::=
SEQUENCE
{
mcmPerfLocation CardLocation,
mcmPerfShelf CardShelf,
mcmPerfSlot INTEGER,
mcmPerfState CardState,
mcmPerfStatus CardStatus,
mcmLastBootTime DateAndTime,
mcmAvailTime Counter,
mcmErrFreeSecs Counter,
mcmBiasCurrent INTEGER,
mcmModulation INTEGER,
mcmApc INTEGER,
mcmIwmModulation INTEGER,
mcmLaserOnOff FlagType,
mcmTemperature Gauge,
mcmIntensity Gauge,
mcmSignalStrength Gauge,
mcmLossOfLight Boolean,
mcmSignalDetect Boolean
}
mcmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card. Valid choices are Local
or Remote. The system automatically selects this
value based on the known (available) mcmt1/mcme1 cards."
::= { mcmPerfEntry 1 }
mcmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 3"
::= { mcmPerfEntry 2 }
mcmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 21"
::= { mcmPerfEntry 3 }
mcmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the mcmt1/mcme1 card. The states' are:
online, offline, empty, loopback or diagnostics."
::= {mcmPerfEntry 4 }
mcmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the channel card. This
status represents the status of the communication
processor and in general is different from the
status of the system."
::= { mcmPerfEntry 5 }
mcmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { mcmPerfEntry 6 }
mcmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this mcmt1/mcme1 has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { mcmPerfEntry 7 }
mcmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this mcmt1/mcme1 has not experienced any alarms."
::= { mcmPerfEntry 8 }
mcmBiasCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Bias current for the optical laser. This value can
be set remotely"
::= { mcmPerfEntry 9 }
mcmModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency modulation for the optical laser. This
value can be adjusted remotely."
::= { mcmPerfEntry 10 }
mcmApc OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The APC value. This value can be set remotely."
::= { mcmPerfEntry 11 }
mcmIwmModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The frequency modulation for the IWM channel. This
value can be adjusted remotely."
::= { mcmPerfEntry 12 }
mcmLaserOnOff OBJECT-TYPE
SYNTAX FlagType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The laser On/Off flag. This value can be set
remotely."
::= { mcmPerfEntry 13 }
mcmTemperature OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current temperature, or the operating temperature
of the optical device."
::= { mcmPerfEntry 14 }
mcmIntensity OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The intensity of the optical light. This value can
be set remotely."
::= { mcmPerfEntry 15 }
mcmSignalStrength OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current signal strength for the optical path."
::= { mcmPerfEntry 16 }
mcmLossOfLight OBJECT-TYPE
SYNTAX Boolean
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If set to true, no laser light is present. If set to
false, no loss of light has occurred."
::= { mcmPerfEntry 17 }
mcmSignalDetect OBJECT-TYPE
SYNTAX Boolean
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If set to true, signal is detected. If set to false,
no signal is present."
::= { mcmPerfEntry 18 }
mcmPortCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmPortCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
MCMT1/MCME1 port's current counters."
::= { mcmPerf 4 }
mcmPortCurrEntry OBJECT-TYPE
SYNTAX McmPortCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmPortCurrCardLocation, mcmPortCurrCardShelf,
mcmPortCurrCardSlot, mcmPortCurrIndex }
::= { mcmPortCurrTable 1 }
McmPortCurrEntry ::=
SEQUENCE
{
mcmPortCurrCardLocation CardLocation,
mcmPortCurrCardShelf CardShelf,
mcmPortCurrCardSlot INTEGER,
mcmPortCurrIndex INTEGER,
mcmPortCurrASs Counter,
mcmPortCurrFrameASs Counter,
mcmPortCurrFEs Counter,
mcmPortCurrCRCErrs Counter,
mcmPortCurrSESs Counter,
mcmPortCurrSEFSs Counter,
mcmPortCurrUASs Counter,
mcmPortCurrLESs Counter,
mcmPortCurrBESs Counter,
mcmPortCurrDMs Counter,
mcmPortCurrLCVs Counter
}
mcmPortCurrCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the MCMT1/MCME1 port. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { mcmPortCurrEntry 1 }
mcmPortCurrCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 2..3."
::= { mcmPortCurrEntry 2 }
mcmPortCurrCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the Module is in."
::= { mcmPortCurrEntry 3 }
mcmPortCurrIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port's index."
::= { mcmPortCurrEntry 4 }
mcmPortCurrASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's ASs counter less than 15 mins."
::= { mcmPortCurrEntry 5 }
mcmPortCurrFrameASs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's FrameASs counter less than 15 mins."
::= { mcmPortCurrEntry 6 }
mcmPortCurrFEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's FEs counter less than 15 mins."
::= { mcmPortCurrEntry 7 }
mcmPortCurrCRCErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's CRC errs counter less than 15 mins."
::= { mcmPortCurrEntry 8 }
mcmPortCurrSESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's SESs counter less than 15 mins."
::= { mcmPortCurrEntry 9 }
mcmPortCurrSEFSs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's SEFSs counter less than 15 mins."
::= { mcmPortCurrEntry 10 }
mcmPortCurrUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's UASs counter less than 15 mins."
::= { mcmPortCurrEntry 11 }
mcmPortCurrLESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's LESs counter less than 15 mins."
::= { mcmPortCurrEntry 12 }
mcmPortCurrBESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's BESs counter less than 15 mins."
::= { mcmPortCurrEntry 13 }
mcmPortCurrDMs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's DMSs counter less than 15 mins."
::= { mcmPortCurrEntry 14 }
mcmPortCurrLCVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's LCVs counter less than 15 mins."
::= { mcmPortCurrEntry 15 }
-- The elements in the fnPerf subgroup of the current subgroup
fnNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
Fans in this time slot (15 minutes)."
::= { fnPerf 1 }
fnPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FnPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each fan module."
::= { fnPerf 2 }
fnPerfEntry OBJECT-TYPE
SYNTAX FnPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fnPerfID }
::= { fnPerfTable 1 }
FnPerfEntry ::=
SEQUENCE
{
fnPerfID INTEGER,
fnPerfState INTEGER,
fnPerfStatus CardStatus
}
fnPerfID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module ID where the fan module is plugged in."
::= { fnPerfEntry 1 }
fnPerfState OBJECT-TYPE
SYNTAX INTEGER { fnEmpty(1), fnOK(2), fnFailed(3), fnDegrade(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the fan module."
::= { fnPerfEntry 2 }
fnPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the fan module. This status
represents the status of the fan module and in general is
different from the status of the system."
::= { fnPerfEntry 3 }
-- The elements in the csimPerf subgroup of the current subgroup
csimNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable keeps track of the number of events
related to ColorSIM. The reason this has been made obsolete
is that all colorsim related events would eventually be part
of ocm events"
::= { csimPerf 1 }
csimCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF CsimCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
colorsim card in the most current interval"
::= { csimPerf 2 }
csimCurrentEntry OBJECT-TYPE
SYNTAX CsimCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below."
INDEX { csimCurrentLocation, csimCurrentShelf, csimCurrentSlot }
::= { csimCurrentTable 1 }
CsimCurrentEntry ::=
SEQUENCE
{
csimCurrentLocation CardLocation,
csimCurrentShelf CardShelf,
csimCurrentSlot INTEGER,
csimCurrentEFIs INTEGER,
csimCurrentEIs INTEGER,
csimCurrentSEIs INTEGER,
csimCurrentBERs DisplayString,
csimCurrentUAIs INTEGER,
csimCurrentGIs INTEGER,
csimCurrentDateTime INTEGER
}
csimCurrentLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Location of the ColorSIM module"
::= { csimCurrentEntry 1 }
csimCurrentShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the ColorSIM module"
::= { csimCurrentEntry 2 }
csimCurrentSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Slot of the ColorSIM module"
::= { csimCurrentEntry 3 }
csimCurrentEFIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Error Free
Interval Counts in the current update (default: 15
minutes) interval."
::= { csimCurrentEntry 4 }
csimCurrentEIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Errored
Interval Counts in the current update (default: 15
minutes) interval."
::= { csimCurrentEntry 5 }
csimCurrentSEIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Severly
Errored Interval Counts in the current update
(default:15 minutes) interval."
::= { csimCurrentEntry 6}
csimCurrentBERs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Bit Error
Rates Counts in the current update (default: 15
minutes) interval. The unit will be in the form of
x.ye-z."
::= { csimCurrentEntry 7 }
csimCurrentUAIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Unavailable
Interval Counts in the current update (default: 15
minutes) interval."
::= { csimCurrentEntry 8 }
csimCurrentGIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of gating intervals over which the data was
collected."
::= { csimCurrentEntry 9 }
csimCurrentDateTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time in seconds elasped since 01/01/1970 00:00:00 GMT. Assuming
local time is same as GMT"
::= { csimCurrentEntry 10 }
-- The elements in the rpsmPerf subgroup of the current subgroup
rpsmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RPSM's in this time slot (15 minutes)."
::= { rpsmPerf 1 }
rpsmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpsmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rpsm card"
::= { rpsmPerf 2 }
rpsmPerfEntry OBJECT-TYPE
SYNTAX RpsmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rpsmPerfLocation, rpsmPerfShelf, rpsmPerfSlot }
::= { rpsmPerfTable 1 }
RpsmPerfEntry ::=
SEQUENCE
{
rpsmPerfLocation CardLocation,
rpsmPerfShelf CardShelf,
rpsmPerfSlot INTEGER,
rpsmPerfState CardState,
rpsmPerfStatus CardStatus,
rpsmLinkEastState INTEGER,
rpsmLinkEastStatus INTEGER,
rpsmLinkWestState INTEGER,
rpsmLinkWestStatus INTEGER,
rpsmLastBootTime DateAndTime,
rpsmAvailTime Counter,
rpsmErrFreeSecs Counter,
rpsmWorkingPower INTEGER,
rpsmProtectionPower INTEGER
}
rpsmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { rpsmPerfEntry 1 }
rpsmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { rpsmPerfEntry 2 }
rpsmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rpsmPerfEntry 3 }
rpsmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the rpsm card. The possible states
are: online, offline, empty, loopback or diag."
::= { rpsmPerfEntry 4 }
rpsmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the rpsm card. This status represents
the status of the rpsm card and in general is
different from the status of the system."
::= { rpsmPerfEntry 5 }
rpsmLinkEastState OBJECT-TYPE
SYNTAX INTEGER
{
linked(1),
notLinked(2),
unknown(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The link state of path East, whether light
is being detected. The states are:
linked, notLinked."
::= { rpsmPerfEntry 6 }
rpsmLinkEastStatus OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
standby(2),
hibernation(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link East of the card and in general
is different from the status of the card."
::= { rpsmPerfEntry 7 }
rpsmLinkWestState OBJECT-TYPE
SYNTAX INTEGER
{
linked(1),
notLinked(2),
unknown(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The link state of path West, whether light
is being detected. The states are:
linked, notLinked."
::= { rpsmPerfEntry 8 }
rpsmLinkWestStatus OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
standby(2),
hibernation(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link West of the card and in general
is different from the status of the card."
::= { rpsmPerfEntry 9 }
rpsmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { rpsmPerfEntry 10 }
rpsmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rpsm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { rpsmPerfEntry 11 }
rpsmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rpsm has not experienced any alarms."
::= { rpsmPerfEntry 12 }
rpsmWorkingPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Working link power of the RPSM card in dBm."
::= { rpsmPerfEntry 13 }
rpsmProtectionPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Protection link power of the RPSM card in dBm."
::= { rpsmPerfEntry 14 }
-- The elements in the rsdmPerf subgroup of the current subgroup
rsdmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RSDM's in this time slot (15 minutes)."
::= { rsdmPerf 1 }
rsdmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsdmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rsdm card"
::= { rsdmPerf 2 }
rsdmPerfEntry OBJECT-TYPE
SYNTAX RsdmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsdmPerfLocation, rsdmPerfShelf, rsdmPerfSlot }
::= { rsdmPerfTable 1 }
RsdmPerfEntry ::=
SEQUENCE
{
rsdmPerfLocation CardLocation,
rsdmPerfShelf CardShelf,
rsdmPerfSlot INTEGER,
rsdmPerfState CardState,
rsdmPerfStatus CardStatus,
rsdmLinkEastState INTEGER,
rsdmLinkEastStatus INTEGER,
rsdmLinkWestState INTEGER,
rsdmLinkWestStatus INTEGER,
rsdmLastBootTime DateAndTime,
rsdmAvailTime Counter,
rsdmErrFreeSecs Counter,
rsdmWorkingPower INTEGER,
rsdmProtectionPower INTEGER
}
rsdmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or remote."
::= { rsdmPerfEntry 1 }
rsdmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { rsdmPerfEntry 2 }
rsdmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rsdmPerfEntry 3 }
rsdmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the rsdm card. The states are:
online, offline."
::= { rsdmPerfEntry 4 }
rsdmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the rsdm card. This status represents
the status of the rsdm card and in general is
different from the status of the system."
::= { rsdmPerfEntry 5 }
rsdmLinkEastState OBJECT-TYPE
SYNTAX INTEGER
{
linked(1),
notLinked(2),
unknown(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The link state of path A, whether light
is being detected. The states are:
linked, notLinked."
::= { rsdmPerfEntry 6 }
rsdmLinkEastStatus OBJECT-TYPE
SYNTAX INTEGER {
active(1),
standby(2),
hibernation(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link East of the card and in general is
different from the status of the card."
::= { rsdmPerfEntry 7 }
rsdmLinkWestState OBJECT-TYPE
SYNTAX INTEGER
{
linked(1),
notLinked(2),
unknown(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The link state of path West, whether light
is being detected. The states are:
linked, notLinked."
::= { rsdmPerfEntry 8 }
rsdmLinkWestStatus OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
standby(2),
hibernation(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link West of the card and in general
is different from the status of the card."
::= { rsdmPerfEntry 9 }
rsdmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { rsdmPerfEntry 10 }
rsdmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rsdm card has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { rsdmPerfEntry 11 }
rsdmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rsdm card has not experienced any alarms."
::= { rsdmPerfEntry 12 }
rsdmWorkingPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Working link power of the RSDM card in dBm."
::= { rsdmPerfEntry 13 }
rsdmProtectionPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Protection link power of the RSDM card in dBm."
::= { rsdmPerfEntry 14 }
-- The elements in the rtdmPerf subgroup of the current subgroup
rtdmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RTDM's in this time slot (15 minutes)."
::= { rtdmPerf 1 }
rtdmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtdmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rtdm card"
::= { rtdmPerf 2 }
rtdmPerfEntry OBJECT-TYPE
SYNTAX RtdmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rtdmPerfLocation, rtdmPerfShelf, rtdmPerfSlot }
::= { rtdmPerfTable 1 }
RtdmPerfEntry ::=
SEQUENCE
{
rtdmPerfLocation CardLocation,
rtdmPerfShelf CardShelf,
rtdmPerfSlot INTEGER,
rtdmPerfState CardState,
rtdmPerfStatus CardStatus,
rtdmLastBootTime DateAndTime,
rtdmAvailTime Counter,
rtdmErrFreeSecs Counter
}
rtdmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { rtdmPerfEntry 1 }
rtdmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { rtdmPerfEntry 2 }
rtdmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rtdmPerfEntry 3 }
rtdmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the rtdm card. The states are:
online, offline, empty, loopback or diag."
::= { rtdmPerfEntry 4 }
rtdmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the rtdm card. This status represents
the status of the rtdm card and in general is
different from the status of the system."
::= { rtdmPerfEntry 5 }
rtdmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { rtdmPerfEntry 6 }
rtdmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rtdm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { rtdmPerfEntry 7 }
rtdmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rtdm has not experienced any alarms."
::= { rtdmPerfEntry 8 }
-- The elements in the osamPerf subgroup of the current subgroup
osamNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received for all osam's in
the most current 15 minutes slot."
::= { osamPerf 1 }
osamCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF OsamCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { osamPerf 2 }
osamCntrEntry OBJECT-TYPE
SYNTAX OsamCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { osamCntrLocation, osamCntrShelf, osamCntrSlot }
::= { osamCntrTable 1 }
OsamCntrEntry ::=
SEQUENCE
{
osamCntrLocation CardLocation,
osamCntrShelf CardShelf,
osamCntrSlot INTEGER,
osamCntrKeepAlivePktSent Counter,
osamCntrKeepAlivePktRcvd Counter,
osamCntrKeepAliveBadPktRcvd Counter
}
osamCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { osamCntrEntry 1 }
osamCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf number in which the module is plugged in."
::= { osamCntrEntry 2 }
osamCntrSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number in which the module is plugged in."
::= { osamCntrEntry 3 }
osamCntrKeepAlivePktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of keep alive packets sent."
::= { osamCntrEntry 4 }
osamCntrKeepAlivePktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of keep alive packets received."
::= { osamCntrEntry 5 }
osamCntrKeepAliveBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of bad keep alive data packets
received."
::= { osamCntrEntry 6 }
osamPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OsamPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each osam card"
::= { osamPerf 3 }
osamPerfEntry OBJECT-TYPE
SYNTAX OsamPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { osamPerfLocation, osamPerfShelf, osamPerfSlot }
::= { osamPerfTable 1 }
OsamPerfEntry ::=
SEQUENCE
{
osamPerfLocation CardLocation,
osamPerfShelf CardShelf,
osamPerfSlot INTEGER,
osamPerfState CardState,
osamPerfStatus CardStatus,
osamPerfLastBootTime DateAndTime,
osamPerfAvailTime Counter,
osamPerfErrFreeSecs Counter,
osamPerfAprStatus FlagType,
osamPerfInputPower DisplayString,
osamPerfBFDPower DisplayString,
osamPerfOutputPower DisplayString,
osamPerfAPRDetector1Power DisplayString,
osamPerfAPRDetector2Power DisplayString,
osamPerfLaserTemperature INTEGER,
osamPerfTecCurrent INTEGER,
osamPerfBiasCurrent INTEGER,
osamPerfAmplifierGain DisplayString,
osamPerfPCBTemperature INTEGER,
osam2PerfPump1BFDPower INTEGER,
osam2PerfPump2BFDPower INTEGER,
osam2PerfPump1IBias INTEGER,
osam2PerfPump2IBias INTEGER,
osam2PerfPump1ITEC INTEGER,
osam2PerfPump2ITEC INTEGER,
osam2PerfPump1Temp DisplayString,
osam2PerfPump2Temp DisplayString,
osam2PerfGBInputPower DisplayString,
osam2PerfGBOutputPower DisplayString,
osam2PerfAttenuation DisplayString
}
osamPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { osamPerfEntry 1 }
osamPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf number in which the module is plugged in."
::= { osamPerfEntry 2 }
osamPerfSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number in which the module is plugged in."
::= { osamPerfEntry 3 }
osamPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of the module."
::= { osamPerfEntry 4 }
osamPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current alarm status of the channel."
::= { osamPerfEntry 5 }
osamPerfLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { osamPerfEntry 6 }
osamPerfAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in the most current 15 minutes
interval that this module has been up and running."
::= { osamPerfEntry 7 }
osamPerfErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in the most current 15 minutes
interval that this module has not experienced any
alarms."
::= { osamPerfEntry 8 }
osamPerfAprStatus OBJECT-TYPE
SYNTAX FlagType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the automatic power reduction mode.
Not applicable to OSAM-HP/LP module"
::= { osamPerfEntry 9 }
osamPerfInputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power at the input in dBm.
Not applicable to OSAM-HP/LP
module"
::= { osamPerfEntry 10 }
osamPerfBFDPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The back facet diode reading in the pump laser;
related to the power output of the pump laser.
This values isn't calibrated and doesn't have a
unit. Not applicable to OSAM-HP/LP module"
::= { osamPerfEntry 11 }
osamPerfOutputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power at the output port in dBm."
::= { osamPerfEntry 12 }
osamPerfAPRDetector1Power OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The automatic power reduction detector 1 reading
in dBm. Two readings are provided for redundancy
purposes. Not applicable to OSAM-HP/LP module"
::= { osamPerfEntry 13 }
osamPerfAPRDetector2Power OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The automatic power reduction detector 2 reading
in dBm. Two readings are provided for redundancy
purposes. Not applicable to OSAM-HP/LP module"
::= { osamPerfEntry 14 }
osamPerfLaserTemperature OBJECT-TYPE
SYNTAX INTEGER (15..35)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The pump laser temperature in degree Celsius.
Not applicable to OSAM-HP/LP module"
::= { osamPerfEntry 15 }
osamPerfTecCurrent OBJECT-TYPE
SYNTAX INTEGER (0..1500)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Thermo-Electric Cooler current in mA.
Not applicable to OSAM-HP/LP module"
::= { osamPerfEntry 16 }
osamPerfBiasCurrent OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The measured pump laser bias current in mA.
Not applicable to OSAM-HP/LP module"
::= { osamPerfEntry 17 }
osamPerfAmplifierGain OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The measured overall amplifier gain in dB."
::= { osamPerfEntry 18 }
osamPerfPCBTemperature OBJECT-TYPE
SYNTAX INTEGER (0..75)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The temperature of the printed circuit board in
degree Celsius."
::= { osamPerfEntry 19 }
osam2PerfPump1BFDPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The back facet diode reading in pump 1 laser;
related to the power output of the pump laser.
Unit to represent the value is DAC (Digital to
Analog converter)"
::= { osamPerfEntry 20 }
osam2PerfPump2BFDPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The back facet diode reading in pump 2 laser;
related to the power output of the pump laser.
Unit to represent the value is DAC (Digital to
Analog converter).
Applicable only for OSAM-HP module"
::= { osamPerfEntry 21 }
osam2PerfPump1IBias OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the bias current of Pump 1 in mA.
The range of values of bias current range from 40 mA -
barely turning on, to MaxIbias - maximum operating current
recommended by the manufacturer.
Pump IBias is used internally to set off alarms and to indicate the
health of the module."
::= { osamPerfEntry 22 }
osam2PerfPump2IBias OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the bias current of Pump 2 in mA.
The range of values of bias current range from 40 mA -
barely turning on, to MaxIbias - maximum operating current
recommended by the manufacturer.
Pump IBias is used internally to set off alarms and to indicate the
health of the module.
Applicable only for OSAM-HP module"
::= { osamPerfEntry 23 }
osam2PerfPump1ITEC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current level in mA of Thermal Electric Cooler (TEC)
used for cooling laser pump 1. "
::= { osamPerfEntry 24 }
osam2PerfPump2ITEC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current level in mA of Thermal Electric Cooler (TEC)
used for cooling laser pump 2.
Applicable only for OSAM-HP"
::= { osamPerfEntry 25 }
osam2PerfPump1Temp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Laser pump (#1) temperature in degree celcius"
::= { osamPerfEntry 26 }
osam2PerfPump2Temp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Laser pump (#2) temperature in degree celcius
Applicable only for OSAM-HP module"
::= { osamPerfEntry 27 }
osam2PerfGBInputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gain block input power in dBm."
::= { osamPerfEntry 28 }
osam2PerfGBOutputPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Gain block output power in dBm with attenuation
set to zero."
::= { osamPerfEntry 29 }
osam2PerfAttenuation OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates optical attenuation in dB imposed by
variable optical attenuator(VOA)"
::= { osamPerfEntry 30 }
-- The elements in the rsmPerf subgroup of the current subgroup
rsmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RSM's in this time slot (15 minutes)."
::= { rsmPerf 1 }
rsmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rsm card"
::= { rsmPerf 2 }
rsmPerfEntry OBJECT-TYPE
SYNTAX RsmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsmPerfLocation, rsmPerfShelf, rsmPerfSlot }
::= { rsmPerfTable 1 }
RsmPerfEntry ::=
SEQUENCE
{
rsmPerfLocation CardLocation,
rsmPerfShelf CardShelf,
rsmPerfSlot CardSlot,
rsmPerfState CardState,
rsmPerfStatus CardStatus,
rsmLinkAState INTEGER,
rsmLinkAStatus INTEGER,
rsmLinkBState INTEGER,
rsmLinkBStatus INTEGER,
rsmLastBootTime DateAndTime,
rsmAvailTime Counter,
rsmErrFreeSecs Counter,
rsmWorkingPower INTEGER,
rsmProtectionPower INTEGER
}
rsmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card."
::= { rsmPerfEntry 1 }
rsmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { rsmPerfEntry 2 }
rsmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rsmPerfEntry 3 }
rsmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the rsm card. The possible states
are: online, offline, empty, loopback or diag."
::= { rsmPerfEntry 4 }
rsmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the rsm card. This status represents
the status of the rsm card and in general is
different from the status of the system."
::= { rsmPerfEntry 5 }
rsmLinkAState OBJECT-TYPE
SYNTAX INTEGER { linked(1), notLinked(2), unknown(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The link state of path A (East), whether light
is being detected. The states are:
linked, notLinked."
::= { rsmPerfEntry 6 }
rsmLinkAStatus OBJECT-TYPE
SYNTAX INTEGER { active(1), standby(2), na(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link A (East) of the card and in general
is different from the status of the card."
::= { rsmPerfEntry 7 }
rsmLinkBState OBJECT-TYPE
SYNTAX INTEGER { linked(1), notLinked(2), unknown(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The link state of path B (West), whether light
is being detected. The states are:
linked, notLinked."
::= { rsmPerfEntry 8 }
rsmLinkBStatus OBJECT-TYPE
SYNTAX INTEGER { active(1), standby(2), na(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link B (West) of the card and in general
is different from the status of the card."
::= { rsmPerfEntry 9 }
rsmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { rsmPerfEntry 10 }
rsmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rsm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { rsmPerfEntry 11 }
rsmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rsm has not experienced any alarms."
::= { rsmPerfEntry 12 }
rsmWorkingPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Working link power of the RSM card in dBm."
::= { rsmPerfEntry 13 }
rsmProtectionPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protection link power of the RSM card in dBm."
::= { rsmPerfEntry 14 }
-- The elements in the upsmPerf subgroup of the current subgroup
upsmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
UPSM's in this time slot (15 minutes)."
::= { upsmPerf 1 }
upsmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each upsm card"
::= { upsmPerf 2 }
upsmPerfEntry OBJECT-TYPE
SYNTAX UpsmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { upsmPerfLocation, upsmPerfShelf, upsmPerfSlot }
::= { upsmPerfTable 1 }
UpsmPerfEntry ::=
SEQUENCE
{
upsmPerfLocation CardLocation,
upsmPerfShelf CardShelf,
upsmPerfSlot CardSlot,
upsmPerfState CardState,
upsmPerfStatus CardStatus,
upsmLinkAState INTEGER,
upsmLinkAStatus INTEGER,
upsmLinkBState INTEGER,
upsmLinkBStatus INTEGER,
upsmLastBootTime DateAndTime,
upsmAvailTime Counter,
upsmErrFreeSecs Counter,
upsmWorkingPower INTEGER,
upsmProtectionPower INTEGER
}
upsmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card."
::= { upsmPerfEntry 1 }
upsmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { upsmPerfEntry 2 }
upsmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { upsmPerfEntry 3 }
upsmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the upsm card. The possible states
are: online, offline, empty, loopback or diag."
::= { upsmPerfEntry 4 }
upsmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the upsm card. This status represents
the status of the upsm card and in general is
different from the status of the system."
::= { upsmPerfEntry 5 }
upsmLinkAState OBJECT-TYPE
SYNTAX INTEGER { linked(1), notLinked(2), unknown(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The link state of path A (East), whether light
is being detected. The states are:
linked, notLinked."
::= { upsmPerfEntry 6 }
upsmLinkAStatus OBJECT-TYPE
SYNTAX INTEGER { active(1), standby(2), hibernation(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link A (East) of the card and in general
is different from the status of the card."
::= { upsmPerfEntry 7 }
upsmLinkBState OBJECT-TYPE
SYNTAX INTEGER { linked(1), notLinked(2), unknown(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The link state of path B (West), whether light
is being detected. The states are:
linked, notLinked."
::= { upsmPerfEntry 8 }
upsmLinkBStatus OBJECT-TYPE
SYNTAX INTEGER { active(1), standby(2), hibernation(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the card channel. This status represents
the status of the link B (West) of the card and in general
is different from the status of the card."
::= { upsmPerfEntry 9 }
upsmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { upsmPerfEntry 10 }
upsmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this upsm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { upsmPerfEntry 11 }
upsmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this upsm has not experienced any alarms."
::= { upsmPerfEntry 12 }
upsmWorkingPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Working link power of the UPSM card in dBm."
::= { upsmPerfEntry 13 }
upsmProtectionPower OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Protection link power of the UPSM card in dBm."
::= { upsmPerfEntry 14 }
-- The elements in the mcmescPerf subgroup of the current subgroup
mcmescNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received for all mcmesc's in
this time slot (15 minutes)."
::= { mcmescPerf 1 }
mcmescCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { mcmescPerf 2 }
mcmescCntrEntry OBJECT-TYPE
SYNTAX McmescCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescCntrLocation, mcmescCntrShelf, mcmescCntrSlot, mcmescCntrType }
::= { mcmescCntrTable 1 }
McmescCntrEntry ::=
SEQUENCE
{
mcmescCntrLocation CardLocation,
mcmescCntrShelf CardShelf,
mcmescCntrSlot INTEGER,
mcmescCntrType INTEGER,
mcmescCounterFlag FlagType,
mcmescTotPktSent Counter,
mcmescTotPktRcvd Counter,
mcmescBadPktRcvd Counter,
mcmescTotBadTrans Counter,
mcmescBytesSent Counter,
mcmescBytesRcvd Counter,
mcmescMsgsDlvrd Counter,
mcmescClearCntrs ResetType
}
mcmescCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the mcmesc card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
mcmesc cards."
::= { mcmescCntrEntry 1 }
mcmescCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 3.
The system automatically determines the right value
for this entry based on the known (available) mcmesc
cards."
::= { mcmescCntrEntry 2 }
mcmescCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 21. The system automatically
determines the right value for this entry based
on the known (available) mcmesc cards."
::= { mcmescCntrEntry 3 }
mcmescCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), iwm(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { mcmescCntrEntry 4 }
mcmescCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Turns software counters On or Off for this mcmesc."
::= { mcmescCntrEntry 5 }
mcmescTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { mcmescCntrEntry 6 }
mcmescTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { mcmescCntrEntry 7 }
mcmescBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { mcmescCntrEntry 8 }
mcmescTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { mcmescCntrEntry 9 }
mcmescBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { mcmescCntrEntry 10 }
mcmescBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { mcmescCntrEntry 11 }
mcmescMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { mcmescCntrEntry 12 }
mcmescClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters
are reset to zero. A get on this will always return other"
::= { mcmescCntrEntry 13 }
mcmescPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each mcmesc card"
::= { mcmescPerf 3 }
mcmescPerfEntry OBJECT-TYPE
SYNTAX McmescPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescPerfLocation, mcmescPerfShelf, mcmescPerfSlot }
::= { mcmescPerfTable 1 }
McmescPerfEntry ::=
SEQUENCE
{
mcmescPerfLocation CardLocation,
mcmescPerfShelf CardShelf,
mcmescPerfSlot INTEGER,
mcmescPerfState CardState,
mcmescPerfStatus CardStatus,
mcmescLastBootTime DateAndTime,
mcmescAvailTime Counter
}
mcmescPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card. Valid choices are Local
or Remote. The system automatically selects this
value based on the known (available) mcmesc cards."
::= { mcmescPerfEntry 1 }
mcmescPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 3"
::= { mcmescPerfEntry 2 }
mcmescPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 21"
::= { mcmescPerfEntry 3 }
mcmescPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the mcmesc card. The states' are:
online, offline, empty, loopback or diagnostics."
::= {mcmescPerfEntry 4 }
mcmescPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the channel card. This
status represents the status of the communication
processor and in general is different from the
status of the system."
::= { mcmescPerfEntry 5 }
mcmescLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { mcmescPerfEntry 6 }
mcmescAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this mcmesc has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { mcmescPerfEntry 7 }
mcmescPortCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescPortCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
mcmesc cpe port's current counters."
::= { mcmescPerf 4 }
mcmescPortCurrEntry OBJECT-TYPE
SYNTAX McmescPortCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescPortCurrCardLocation, mcmescPortCurrCardShelf,
mcmescPortCurrCardSlot, mcmescPortCurrPort }
::= { mcmescPortCurrTable 1 }
McmescPortCurrEntry ::=
SEQUENCE
{
mcmescPortCurrCardLocation CardLocation,
mcmescPortCurrCardShelf CardShelf,
mcmescPortCurrCardSlot INTEGER,
mcmescPortCurrPort INTEGER,
mcmescPortCurrRxSig DisplayString,
mcmescPortCurrDuration DisplayString,
mcmescPortCurrEns DisplayString,
mcmescPortCurrLoss DisplayString,
mcmescPortCurrCrcErr DisplayString,
mcmescPortCurrOobErr DisplayString,
mcmescPortCurrRdpErr DisplayString,
mcmescPortCurrBer DisplayString
}
mcmescPortCurrCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the MCMESC CPE port. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { mcmescPortCurrEntry 1 }
mcmescPortCurrCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 2..3."
::= { mcmescPortCurrEntry 2 }
mcmescPortCurrCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the Module is in."
::= { mcmescPortCurrEntry 3 }
mcmescPortCurrPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE port's index."
::= { mcmescPortCurrEntry 4 }
mcmescPortCurrRxSig OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE port's receive signal power."
::= { mcmescPortCurrEntry 5 }
mcmescPortCurrDuration OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc CPE port's current ongoing interval duration."
::= { mcmescPortCurrEntry 6 }
mcmescPortCurrEns OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc CPE port's enabled seconds during current ongoing
interval."
::= { mcmescPortCurrEntry 7 }
mcmescPortCurrLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc CPE port's loss of signal seconds during current
ongoing interval."
::= { mcmescPortCurrEntry 8 }
mcmescPortCurrCrcErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc CPE port's CRC error counter during current
ongoing interval."
::= { mcmescPortCurrEntry 9 }
mcmescPortCurrOobErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc CPE port's Out-Of_Band error counter during current
ongoing interval."
::= { mcmescPortCurrEntry 10 }
mcmescPortCurrRdpErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc CPE port's Running Disparity error counter during current
ongoing interval."
::= { mcmescPortCurrEntry 11 }
mcmescPortCurrBer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc CPE port's BER, in the form of x.yE-z."
::= { mcmescPortCurrEntry 12 }
mcmescLinkCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescLinkCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
mcmesc cpe port's current counters."
::= { mcmescPerf 5 }
mcmescLinkCurrEntry OBJECT-TYPE
SYNTAX McmescLinkCurrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescLinkCurrCardLocation, mcmescLinkCurrCardShelf,
mcmescLinkCurrCardSlot }
::= { mcmescLinkCurrTable 1 }
McmescLinkCurrEntry ::=
SEQUENCE
{
mcmescLinkCurrCardLocation CardLocation,
mcmescLinkCurrCardShelf CardShelf,
mcmescLinkCurrCardSlot INTEGER,
mcmescLinkCurrRxSig DisplayString,
mcmescLinkCurrDuration DisplayString,
mcmescLinkCurrTsos DisplayString,
mcmescLinkCurrLoss DisplayString,
mcmescLinkCurrCrcErr DisplayString,
mcmescLinkCurrOobErr DisplayString,
mcmescLinkCurrRdpErr DisplayString,
mcmescLinkCurrBer DisplayString
}
mcmescLinkCurrCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the MCMESC CPE port. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { mcmescLinkCurrEntry 1 }
mcmescLinkCurrCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 2..3."
::= { mcmescLinkCurrEntry 2 }
mcmescLinkCurrCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the Module is in."
::= { mcmescLinkCurrEntry 3 }
mcmescLinkCurrRxSig OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link port's receive signal power."
::= { mcmescLinkCurrEntry 4 }
mcmescLinkCurrDuration OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc LINK port's current ongoing interval duration."
::= { mcmescLinkCurrEntry 5 }
mcmescLinkCurrTsos OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc LINK port's test-sequence on seconds during current ongoing
interval."
::= { mcmescLinkCurrEntry 6 }
mcmescLinkCurrLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc LINK port's loss of signal seconds during current
ongoing interval."
::= { mcmescLinkCurrEntry 7 }
mcmescLinkCurrCrcErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc LINK port's CRC error counter during current
ongoing interval."
::= { mcmescLinkCurrEntry 8 }
mcmescLinkCurrOobErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc LINK port's Out-Of_Band error counter during current
ongoing interval."
::= { mcmescLinkCurrEntry 9 }
mcmescLinkCurrRdpErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc LINK port's Running Disparity error counter during current
ongoing interval."
::= { mcmescLinkCurrEntry 10 }
mcmescLinkCurrBer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"mcmesc LINK port's BER, in the form of x.yE-z."
::= { mcmescLinkCurrEntry 11 }
-- The elements in the routingPerf subgroup of the current subgroup
imnRoutingPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF ImnRoutingPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each route"
::= { routingPerf 1 }
imnRoutingPerfEntry OBJECT-TYPE
SYNTAX ImnRoutingPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { imnRoutePerfIpDest}
::= { imnRoutingPerfTable 1 }
ImnRoutingPerfEntry ::=
SEQUENCE
{
imnRoutePerfIpDest IpAddress,
imnRoutePerfStatus INTEGER
}
imnRoutePerfIpDest OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Destination IP address. Not supported for
remote TMM masters."
::= { imnRoutingPerfEntry 1}
imnRoutePerfStatus OBJECT-TYPE
SYNTAX INTEGER { dead(1), comatose(2), active(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Is the route active, comatose or dead"
::= { imnRoutingPerfEntry 2}
-- The elements in the muxPerf subgroup of the current subgroup
tapNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
TAP modules in this time slot (15 minutes)."
::= { tapPerf 1 }
tapPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF TapPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each TAP module."
::= { tapPerf 2 }
tapPerfEntry OBJECT-TYPE
SYNTAX TapPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { tapPerfLocation, tapPerfShelf, tapPerfSlot }
::= { tapPerfTable 1 }
TapPerfEntry ::=
SEQUENCE
{
tapPerfLocation CardLocation,
tapPerfShelf CardShelf,
tapPerfSlot INTEGER,
tapType INTEGER,
tapPerfState CardState,
tapPerfStatus CardStatus,
tapLastBootTime DateAndTime,
tapAvailTime Counter,
tapErrFreeSecs Counter
}
tapPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { tapPerfEntry 1 }
tapPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { tapPerfEntry 2 }
tapPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { tapPerfEntry 3 }
tapType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module type."
::= { tapPerfEntry 4 }
tapPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the TAP module. The states are:
online, offline, empty, loopback or diag."
::= { tapPerfEntry 5 }
tapPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the TAP module. This status represents
the status of the TAP module and in general is
different from the status of the system."
::= { tapPerfEntry 6 }
tapLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { tapPerfEntry 7 }
tapAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { tapPerfEntry 8 }
tapErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { tapPerfEntry 9 }
-- The elements in the voadmPerf subgroup of the current subgroup
voadmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
VOADM modules in this time slot (15 minutes)."
::= { voadmPerf 1 }
voadmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoadmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each VOADM module."
::= { voadmPerf 2 }
voadmPerfEntry OBJECT-TYPE
SYNTAX VoadmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { voadmPerfLocation, voadmPerfShelf, voadmPerfSlot }
::= { voadmPerfTable 1 }
VoadmPerfEntry ::=
SEQUENCE
{
voadmPerfLocation CardLocation,
voadmPerfShelf CardShelf,
voadmPerfSlot INTEGER,
voadmType INTEGER,
voadmPerfState CardState,
voadmPerfStatus CardStatus,
voadmLastBootTime DateAndTime,
voadmAvailTime Counter,
voadmErrFreeSecs Counter
}
voadmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { voadmPerfEntry 1 }
voadmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { voadmPerfEntry 2 }
voadmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { voadmPerfEntry 3 }
voadmType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module type."
::= { voadmPerfEntry 4 }
voadmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the VOADM module. The states are:
online, offline, empty, loopback or diag."
::= { voadmPerfEntry 5 }
voadmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the VOADM module. This status represents
the status of the VOADM module and in general is
different from the status of the system."
::= { voadmPerfEntry 6 }
voadmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { voadmPerfEntry 7 }
voadmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { voadmPerfEntry 8 }
voadmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { voadmPerfEntry 9 }
-- The elements in the dmmPerf subgroup of the current subgroup
dmmNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
DMM modules in this time slot (15 minutes)."
::= { dmmPerf 1 }
dmmPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each DMM module."
::= { dmmPerf 2 }
dmmPerfEntry OBJECT-TYPE
SYNTAX DmmPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dmmPerfLocation, dmmPerfShelf, dmmPerfSlot }
::= { dmmPerfTable 1 }
DmmPerfEntry ::=
SEQUENCE
{
dmmPerfLocation CardLocation,
dmmPerfShelf CardShelf,
dmmPerfSlot INTEGER,
dmmPerfState CardState,
dmmPerfStatus CardStatus,
dmmLastBootTime DateAndTime,
dmmAvailTime Counter,
dmmErrFreeSecs Counter
}
dmmPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { dmmPerfEntry 1 }
dmmPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { dmmPerfEntry 2 }
dmmPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { dmmPerfEntry 3 }
dmmPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the DMM module. The states are:
online, offline, empty, loopback or diag."
::= { dmmPerfEntry 4 }
dmmPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the DMM module. This status represents
the status of the DMM module and in general is
different from the status of the system."
::= { dmmPerfEntry 5 }
dmmLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { dmmPerfEntry 6 }
dmmAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { dmmPerfEntry 7 }
dmmErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { dmmPerfEntry 8 }
dmmCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { dmmPerf 3 }
dmmCntrEntry OBJECT-TYPE
SYNTAX DmmCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dmmCntrLocation, dmmCntrShelf, dmmCntrSlot, dmmCntrType }
::= { dmmCntrTable 1 }
DmmCntrEntry ::=
SEQUENCE
{
dmmCntrLocation CardLocation,
dmmCntrShelf CardShelf,
dmmCntrSlot INTEGER,
dmmCntrType INTEGER,
dmmTotPktSent Counter,
dmmTotPktRcvd Counter,
dmmTotBadTrans Counter,
dmmBadPktRcvd Counter,
dmmBytesSent Counter,
dmmBytesRcvd Counter,
dmmMsgsDlvrd Counter,
dmmClearCntrs ResetType
}
dmmCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the DMM card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
DMM cards."
::= { dmmCntrEntry 1 }
dmmCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) DMM
cards."
::= { dmmCntrEntry 2 }
dmmCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) DMM cards."
::= { dmmCntrEntry 3 }
dmmCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), ibm(2), hdlc(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row."
::= { dmmCntrEntry 4 }
dmmTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { dmmCntrEntry 5 }
dmmTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { dmmCntrEntry 6 }
dmmTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { dmmCntrEntry 7 }
dmmBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { dmmCntrEntry 8 }
dmmBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { dmmCntrEntry 9 }
dmmBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { dmmCntrEntry 10 }
dmmMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { dmmCntrEntry 11 }
dmmClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other"
::= { dmmCntrEntry 12 }
dmmPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { dmmPerf 4 }
dmmPmEntry OBJECT-TYPE
SYNTAX DmmPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dmmPmLocation, dmmPmShelf, dmmPmSlot, dmmPmType }
::= { dmmPmTable 1 }
DmmPmEntry ::=
SEQUENCE
{
dmmPmLocation CardLocation,
dmmPmShelf CardShelf,
dmmPmSlot INTEGER,
dmmPmType INTEGER,
dmmPmErrors Counter,
dmmPmErredSecs Counter,
dmmStartTime DateAndTime,
dmmClearPmCntrs ResetType,
dmmPmRxPower DisplayString,
dmmPmTxPower DisplayString
}
dmmPmLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the DMM card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
DMM cards."
::= { dmmPmEntry 1 }
dmmPmShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) DMM
cards."
::= { dmmPmEntry 2 }
dmmPmSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) DMM cards."
::= { dmmPmEntry 3 }
dmmPmType OBJECT-TYPE
SYNTAX INTEGER { link(1), port1(2), port2(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row."
::= { dmmPmEntry 4 }
dmmPmErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets errors since port last came online."
::= { dmmPmEntry 5 }
dmmPmErredSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of erred seconds since port last came online."
::= { dmmPmEntry 6 }
dmmStartTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date/time the port came last online."
::= { dmmPmEntry 7 }
dmmClearPmCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all PM counters for this
port are reset to zero. A get on this will always
return other"
::= { dmmPmEntry 8 }
dmmPmRxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port receive power."
::= { dmmPmEntry 9 }
dmmPmTxPower OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port receive power."
::= { dmmPmEntry 10 }
-- The elements in the ocm10gfPerf subgroup of the current subgroup
ocm10gfNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OCM10GF modules in this time slot (15 minutes)."
::= { ocm10gfPerf 1 }
ocm10gfPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm10gfPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OCM10GF module."
::= { ocm10gfPerf 2 }
ocm10gfPerfEntry OBJECT-TYPE
SYNTAX Ocm10gfPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm10gfPerfLocation, ocm10gfPerfShelf, ocm10gfPerfSlot }
::= { ocm10gfPerfTable 1 }
Ocm10gfPerfEntry ::=
SEQUENCE
{
ocm10gfPerfLocation CardLocation,
ocm10gfPerfShelf CardShelf,
ocm10gfPerfSlot INTEGER,
ocm10gfPerfState CardState,
ocm10gfPerfStatus CardStatus,
ocm10gfLastBootTime DateAndTime,
ocm10gfAvailTime Counter,
ocm10gfErrFreeSecs Counter
}
ocm10gfPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { ocm10gfPerfEntry 1 }
ocm10gfPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { ocm10gfPerfEntry 2 }
ocm10gfPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { ocm10gfPerfEntry 3 }
ocm10gfPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the OCM10GF module. The states are:
online, offline, empty, loopback or diag."
::= { ocm10gfPerfEntry 4 }
ocm10gfPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the OCM10GF module. This status represents
the status of the OCM10GF module and in general is
different from the status of the system."
::= { ocm10gfPerfEntry 5 }
ocm10gfLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { ocm10gfPerfEntry 6 }
ocm10gfAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { ocm10gfPerfEntry 7 }
ocm10gfErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { ocm10gfPerfEntry 8 }
ocm10gfCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm10gfCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ocm10gfPerf 3 }
ocm10gfCntrEntry OBJECT-TYPE
SYNTAX Ocm10gfCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm10gfCntrLocation, ocm10gfCntrShelf, ocm10gfCntrSlot, ocm10gfCntrType }
::= { ocm10gfCntrTable 1 }
Ocm10gfCntrEntry ::=
SEQUENCE
{
ocm10gfCntrLocation CardLocation,
ocm10gfCntrShelf CardShelf,
ocm10gfCntrSlot INTEGER,
ocm10gfCntrType INTEGER,
ocm10gfTotPktSent Counter,
ocm10gfTotPktRcvd Counter,
ocm10gfTotBadTrans Counter,
ocm10gfBadPktRcvd Counter,
ocm10gfBytesSent Counter,
ocm10gfBytesRcvd Counter,
ocm10gfMsgsDlvrd Counter,
ocm10gfClearCntrs ResetType
}
ocm10gfCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OCM10GF card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OCM10GF cards."
::= { ocm10gfCntrEntry 1 }
ocm10gfCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OCM10GF
cards."
::= { ocm10gfCntrEntry 2 }
ocm10gfCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OCM10GF cards."
::= { ocm10gfCntrEntry 3 }
ocm10gfCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), ibm(2), hdlc(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row."
::= { ocm10gfCntrEntry 4 }
ocm10gfTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { ocm10gfCntrEntry 5 }
ocm10gfTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { ocm10gfCntrEntry 6 }
ocm10gfTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { ocm10gfCntrEntry 7 }
ocm10gfBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { ocm10gfCntrEntry 8 }
ocm10gfBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { ocm10gfCntrEntry 9 }
ocm10gfBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { ocm10gfCntrEntry 10 }
ocm10gfMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { ocm10gfCntrEntry 11 }
ocm10gfClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other"
::= { ocm10gfCntrEntry 12 }
ocm10gfPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm10gfPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ocm10gfPerf 4 }
ocm10gfPmEntry OBJECT-TYPE
SYNTAX Ocm10gfPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm10gfPmLocation, ocm10gfPmShelf, ocm10gfPmSlot }
::= { ocm10gfPmTable 1 }
Ocm10gfPmEntry ::=
SEQUENCE
{
ocm10gfPmLocation CardLocation,
ocm10gfPmShelf CardShelf,
ocm10gfPmSlot INTEGER,
ocm10gfPmNumIntervals INTEGER,
ocm10gfPmLinkRxPwr DisplayString,
ocm10gfPmLinkTxPwr DisplayString,
ocm10gfPmLinkFecErrors DisplayString,
ocm10gfPmLinkUncorrectedFecErrs Counter,
ocm10gfPmLinkCorrectedFecErrs DisplayString,
ocm10gfPmLinkCorrectedOnesErr DisplayString,
ocm10gfPmLinkErredSeconds Counter,
ocm10gfPmCpeRxPwr DisplayString,
ocm10gfPmCpeTxPwr DisplayString,
ocm10gfPmCpeSonetRxB2Errs DisplayString,
ocm10gfPmCpeSonetTxB2Errs DisplayString,
ocm10gfPmCpe10GbeRxTotalPkts DisplayString,
ocm10gfPmCpe10GbeRxErredPkts DisplayString,
ocm10gfPmCpe10GbeTxTotalPkts DisplayString,
ocm10gfPmCpe10gbeTxErredPkts DisplayString,
ocm10gfPmCpeErredSeconds Counter,
ocm10gfClearPmCntrs ResetType
}
ocm10gfPmLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OCM10GF card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OCM10GF cards."
::= { ocm10gfPmEntry 1 }
ocm10gfPmShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OCM10GF
cards."
::= { ocm10gfPmEntry 2 }
ocm10gfPmSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OCM10GF cards."
::= { ocm10gfPmEntry 3 }
ocm10gfPmNumIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 4 }
ocm10gfPmLinkRxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 5 }
ocm10gfPmLinkTxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 6 }
ocm10gfPmLinkFecErrors OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 7 }
ocm10gfPmLinkUncorrectedFecErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 8 }
ocm10gfPmLinkCorrectedFecErrs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 9 }
ocm10gfPmLinkCorrectedOnesErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 10 }
ocm10gfPmLinkErredSeconds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 11 }
ocm10gfPmCpeRxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 12 }
ocm10gfPmCpeTxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 13 }
ocm10gfPmCpeSonetRxB2Errs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 14 }
ocm10gfPmCpeSonetTxB2Errs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 15 }
ocm10gfPmCpe10GbeRxTotalPkts OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 16 }
ocm10gfPmCpe10GbeRxErredPkts OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 17 }
ocm10gfPmCpe10GbeTxTotalPkts OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 18 }
ocm10gfPmCpe10gbeTxErredPkts OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 19 }
ocm10gfPmCpeErredSeconds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
""
::= { ocm10gfPmEntry 20 }
ocm10gfClearPmCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all PM counters for this
port are reset to zero. A get on this will always
return other"
::= { ocm10gfPmEntry 21 }
-- The elements in the ocm2Perf subgroup of the current subgroup
ocm2NumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OCM2 modules in this time slot (15 minutes)."
::= { ocm2Perf 1 }
ocm2PerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm2PerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OCM2 module."
::= { ocm2Perf 2 }
ocm2PerfEntry OBJECT-TYPE
SYNTAX Ocm2PerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm2PerfLocation, ocm2PerfShelf, ocm2PerfSlot }
::= { ocm2PerfTable 1 }
Ocm2PerfEntry ::=
SEQUENCE
{
ocm2PerfLocation CardLocation,
ocm2PerfShelf CardShelf,
ocm2PerfSlot INTEGER,
ocm2PerfState CardState,
ocm2PerfStatus CardStatus,
ocm2LastBootTime DateAndTime,
ocm2AvailTime Counter,
ocm2ErrFreeSecs Counter
}
ocm2PerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { ocm2PerfEntry 1 }
ocm2PerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { ocm2PerfEntry 2 }
ocm2PerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { ocm2PerfEntry 3 }
ocm2PerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the OCM2 module. The states are:
online, offline, empty, loopback or diag."
::= { ocm2PerfEntry 4 }
ocm2PerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the OCM2 module. This status represents
the status of the OCM2 module and in general is
different from the status of the system."
::= { ocm2PerfEntry 5 }
ocm2LastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { ocm2PerfEntry 6 }
ocm2AvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { ocm2PerfEntry 7 }
ocm2ErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { ocm2PerfEntry 8 }
ocm2CntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm2CntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ocm2Perf 3 }
ocm2CntrEntry OBJECT-TYPE
SYNTAX Ocm2CntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm2CntrLocation, ocm2CntrShelf, ocm2CntrSlot, ocm2CntrType }
::= { ocm2CntrTable 1 }
Ocm2CntrEntry ::=
SEQUENCE
{
ocm2CntrLocation CardLocation,
ocm2CntrShelf CardShelf,
ocm2CntrSlot INTEGER,
ocm2CntrType INTEGER,
ocm2TotPktSent Counter,
ocm2TotPktRcvd Counter,
ocm2TotBadTrans Counter,
ocm2BadPktRcvd Counter,
ocm2BytesSent Counter,
ocm2BytesRcvd Counter,
ocm2MsgsDlvrd Counter,
ocm2ClearCntrs ResetType
}
ocm2CntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OCM2 card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OCM2 cards."
::= { ocm2CntrEntry 1 }
ocm2CntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OCM2
cards."
::= { ocm2CntrEntry 2 }
ocm2CntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OCM2 cards."
::= { ocm2CntrEntry 3 }
ocm2CntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), ibm1(2), ibm2(3), hdlc(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row."
::= { ocm2CntrEntry 4 }
ocm2TotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { ocm2CntrEntry 5 }
ocm2TotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { ocm2CntrEntry 6 }
ocm2TotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { ocm2CntrEntry 7 }
ocm2BadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { ocm2CntrEntry 8 }
ocm2BytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { ocm2CntrEntry 9 }
ocm2BytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { ocm2CntrEntry 10 }
ocm2MsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { ocm2CntrEntry 11 }
ocm2ClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other"
::= { ocm2CntrEntry 12 }
ocm2PmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm2PmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ocm2Perf 4 }
ocm2PmEntry OBJECT-TYPE
SYNTAX Ocm2PmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm2PmLocation, ocm2PmShelf, ocm2PmSlot, ocm2PmLink }
::= { ocm2PmTable 1 }
Ocm2PmEntry ::=
SEQUENCE
{
ocm2PmLocation CardLocation,
ocm2PmShelf CardShelf,
ocm2PmSlot CardSlot,
ocm2PmLink INTEGER,
ocm2PmLinkRxPwr DisplayString,
ocm2PmLinkTxPwr DisplayString,
ocm2PmCpeRxPwr DisplayString,
ocm2PmCpeTxPwr DisplayString,
ocm2PmNumLinkRxIntervals INTEGER,
ocm2PmLinkRxErrors DisplayString,
ocm2PmLinkRxErredSeconds Counter,
ocm2PmNumCpeRxIntervals INTEGER,
ocm2PmCpeRxErrors DisplayString,
ocm2PmCpeRxErredSeconds Counter,
ocm2PmNumCpeTxIntervals INTEGER,
ocm2PmCpeTxErrors DisplayString,
ocm2PmCpeTxErredSeconds Counter,
ocm2ClearPmCntrs ResetType
}
ocm2PmLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OCM2 card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OCM2 cards."
::= { ocm2PmEntry 1 }
ocm2PmShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OCM2
cards."
::= { ocm2PmEntry 2 }
ocm2PmSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OCM2 cards."
::= { ocm2PmEntry 3 }
ocm2PmLink OBJECT-TYPE
SYNTAX INTEGER { link1(1), link2(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The link for which statistics are for."
::= { ocm2PmEntry 4 }
ocm2PmLinkRxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link receive power."
::= { ocm2PmEntry 5 }
ocm2PmLinkTxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link transmit power."
::= { ocm2PmEntry 6 }
ocm2PmCpeRxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE receive power."
::= { ocm2PmEntry 7 }
ocm2PmCpeTxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE transmit power."
::= { ocm2PmEntry 8 }
ocm2PmNumLinkRxIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The of intervals (seconds) over which the link Rx
statistics have been accumulated."
::= { ocm2PmEntry 9 }
ocm2PmLinkRxErrors OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link receive errors."
::= { ocm2PmEntry 10 }
ocm2PmLinkRxErredSeconds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link receive errored seconds."
::= { ocm2PmEntry 11 }
ocm2PmNumCpeRxIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The of intervals (seconds) over which the CPE Rx
statistics have been accumulated."
::= { ocm2PmEntry 12 }
ocm2PmCpeRxErrors OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE receive errors."
::= { ocm2PmEntry 13 }
ocm2PmCpeRxErredSeconds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE receive errored seconds."
::= { ocm2PmEntry 14 }
ocm2PmNumCpeTxIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The of intervals (seconds) over which the CPE Tx
statistics have been accumulated."
::= { ocm2PmEntry 15 }
ocm2PmCpeTxErrors OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE transmit errors."
::= { ocm2PmEntry 16 }
ocm2PmCpeTxErredSeconds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE transmit errored seconds."
::= { ocm2PmEntry 17 }
ocm2ClearPmCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all PM counters for this
port are reset to zero. A get on this will always
return other"
::= { ocm2PmEntry 18 }
-- The elements in the oscPerf subgroup of the current subgroup
oscNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OSC modules in this time slot (15 minutes)."
::= { oscPerf 1 }
oscPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OSC module."
::= { oscPerf 2 }
oscPerfEntry OBJECT-TYPE
SYNTAX OscPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oscPerfLocation, oscPerfShelf, oscPerfSlot }
::= { oscPerfTable 1 }
OscPerfEntry ::=
SEQUENCE
{
oscPerfLocation CardLocation,
oscPerfShelf CardShelf,
oscPerfSlot INTEGER,
oscPerfState CardState,
oscPerfStatus CardStatus,
oscLastBootTime DateAndTime,
oscAvailTime Counter,
oscErrFreeSecs Counter
}
oscPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { oscPerfEntry 1 }
oscPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { oscPerfEntry 2 }
oscPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { oscPerfEntry 3 }
oscPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the OSC module. The states are:
online, offline, empty, loopback or diag."
::= { oscPerfEntry 4 }
oscPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the OSC module. This status represents
the status of the OSC module and in general is
different from the status of the system."
::= { oscPerfEntry 5 }
oscLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { oscPerfEntry 6 }
oscAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { oscPerfEntry 7 }
oscErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { oscPerfEntry 8 }
oscCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { oscPerf 3 }
oscCntrEntry OBJECT-TYPE
SYNTAX OscCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oscCntrLocation, oscCntrShelf, oscCntrSlot, oscCntrType }
::= { oscCntrTable 1 }
OscCntrEntry ::=
SEQUENCE
{
oscCntrLocation CardLocation,
oscCntrShelf CardShelf,
oscCntrSlot INTEGER,
oscCntrType INTEGER,
oscTotPktSent Counter,
oscTotPktRcvd Counter,
oscTotBadTrans Counter,
oscBadPktRcvd Counter,
oscBytesSent Counter,
oscBytesRcvd Counter,
oscMsgsDlvrd Counter,
oscClearCntrs ResetType
}
oscCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OSC card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OSC cards."
::= { oscCntrEntry 1 }
oscCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OSC
cards."
::= { oscCntrEntry 2 }
oscCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OSC cards."
::= { oscCntrEntry 3 }
oscCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), ibm(2), hdlc(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row."
::= { oscCntrEntry 4 }
oscTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { oscCntrEntry 5 }
oscTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { oscCntrEntry 6 }
oscTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { oscCntrEntry 7 }
oscBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { oscCntrEntry 8 }
oscBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { oscCntrEntry 9 }
oscBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { oscCntrEntry 10 }
oscMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { oscCntrEntry 11 }
oscClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other"
::= { oscCntrEntry 12 }
oscPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { oscPerf 4 }
oscPmEntry OBJECT-TYPE
SYNTAX OscPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oscPmLocation, oscPmShelf, oscPmSlot }
::= { oscPmTable 1 }
OscPmEntry ::=
SEQUENCE
{
oscPmLocation CardLocation,
oscPmShelf CardShelf,
oscPmSlot INTEGER,
oscPmErrors Counter,
oscPmErredSecs Counter,
oscStartTime DateAndTime,
oscClearPmCntrs ResetType
}
oscPmLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OSC card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OSC cards."
::= { oscPmEntry 1 }
oscPmShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OSC
cards."
::= { oscPmEntry 2 }
oscPmSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OSC cards."
::= { oscPmEntry 3 }
oscPmErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets errors since port last came online."
::= { oscPmEntry 4 }
oscPmErredSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of erred seconds since port last came online."
::= { oscPmEntry 5 }
oscStartTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date/time the port came last online."
::= { oscPmEntry 6 }
oscClearPmCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all PM counters for this
port are reset to zero. A get on this will always
return other"
::= { oscPmEntry 7 }
-- The elements in the ocm4gPerf subgroup of the current subgroup
ocm4gNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OCM4G modules in this time slot (15 minutes)."
::= { ocm4gPerf 1 }
ocm4gPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm4gPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OCM4G module."
::= { ocm4gPerf 2 }
ocm4gPerfEntry OBJECT-TYPE
SYNTAX Ocm4gPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm4gPerfLocation, ocm4gPerfShelf, ocm4gPerfSlot }
::= { ocm4gPerfTable 1 }
Ocm4gPerfEntry ::=
SEQUENCE
{
ocm4gPerfLocation INTEGER,
ocm4gPerfShelf CardShelf,
ocm4gPerfSlot INTEGER,
ocm4gPerfState CardState,
ocm4gPerfStatus CardStatus,
ocm4gLastBootTime DateAndTime,
ocm4gAvailTime Counter,
ocm4gErrFreeSecs Counter
}
ocm4gPerfLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { ocm4gPerfEntry 1 }
ocm4gPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { ocm4gPerfEntry 2 }
ocm4gPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { ocm4gPerfEntry 3 }
ocm4gPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the OCM4G module. The states are:
online, offline, empty, loopback or diag."
::= { ocm4gPerfEntry 4 }
ocm4gPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the OCM4G module. This status represents
the status of the OCM4G module and in general is
different from the status of the system."
::= { ocm4gPerfEntry 5 }
ocm4gLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { ocm4gPerfEntry 6 }
ocm4gAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { ocm4gPerfEntry 7 }
ocm4gErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { ocm4gPerfEntry 8 }
ocm4gCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm4gCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ocm4gPerf 3 }
ocm4gCntrEntry OBJECT-TYPE
SYNTAX Ocm4gCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm4gCntrLocation, ocm4gCntrShelf, ocm4gCntrSlot, ocm4gCntrType }
::= { ocm4gCntrTable 1 }
Ocm4gCntrEntry ::=
SEQUENCE
{
ocm4gCntrLocation INTEGER,
ocm4gCntrShelf CardShelf,
ocm4gCntrSlot INTEGER,
ocm4gCntrType INTEGER,
ocm4gTotPktSent Counter,
ocm4gTotPktRcvd Counter,
ocm4gTotBadTrans Counter,
ocm4gBadPktRcvd Counter,
ocm4gBytesSent Counter,
ocm4gBytesRcvd Counter,
ocm4gMsgsDlvrd Counter,
ocm4gClearCntrs ResetType
}
ocm4gCntrLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OCM4G card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OCM4G cards."
::= { ocm4gCntrEntry 1 }
ocm4gCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OCM4G
cards."
::= { ocm4gCntrEntry 2 }
ocm4gCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OCM4G cards."
::= { ocm4gCntrEntry 3 }
ocm4gCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), ibm1(2), ibm2(3), hdlc(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row."
::= { ocm4gCntrEntry 4 }
ocm4gTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { ocm4gCntrEntry 5 }
ocm4gTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { ocm4gCntrEntry 6 }
ocm4gTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { ocm4gCntrEntry 7 }
ocm4gBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { ocm4gCntrEntry 8 }
ocm4gBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { ocm4gCntrEntry 9 }
ocm4gBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { ocm4gCntrEntry 10 }
ocm4gMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { ocm4gCntrEntry 11 }
ocm4gClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other"
::= { ocm4gCntrEntry 12 }
ocm4gPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm4gPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ocm4gPerf 4 }
ocm4gPmEntry OBJECT-TYPE
SYNTAX Ocm4gPmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm4gPmLocation, ocm4gPmShelf, ocm4gPmSlot, ocm4gPmLink }
::= { ocm4gPmTable 1 }
Ocm4gPmEntry ::=
SEQUENCE
{
ocm4gPmLocation INTEGER,
ocm4gPmShelf CardShelf,
ocm4gPmSlot CardSlot,
ocm4gPmLink INTEGER,
ocm4gPmLinkRxPwr DisplayString,
ocm4gPmLinkTxPwr DisplayString,
ocm4gPmCpeRxPwr DisplayString,
ocm4gPmCpeTxPwr DisplayString,
ocm4gPmNumLinkRxIntervals INTEGER,
ocm4gPmLinkRxErrors DisplayString,
ocm4gPmLinkRxErredSeconds Counter,
ocm4gPmNumCpeRxIntervals INTEGER,
ocm4gPmCpeRxErrors DisplayString,
ocm4gPmCpeRxErredSeconds Counter,
ocm4gPmNumCpeTxIntervals INTEGER,
ocm4gPmCpeTxErrors DisplayString,
ocm4gPmCpeTxErredSeconds Counter,
ocm4gClearPmCntrs ResetType
}
ocm4gPmLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OCM4G card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OCM4G cards."
::= { ocm4gPmEntry 1 }
ocm4gPmShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OCM4G
cards."
::= { ocm4gPmEntry 2 }
ocm4gPmSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OCM4G cards."
::= { ocm4gPmEntry 3 }
ocm4gPmLink OBJECT-TYPE
SYNTAX INTEGER { link1(1), link2(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The link for which statistics are for."
::= { ocm4gPmEntry 4 }
ocm4gPmLinkRxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link receive power."
::= { ocm4gPmEntry 5 }
ocm4gPmLinkTxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link transmit power."
::= { ocm4gPmEntry 6 }
ocm4gPmCpeRxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE receive power."
::= { ocm4gPmEntry 7 }
ocm4gPmCpeTxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE transmit power."
::= { ocm4gPmEntry 8 }
ocm4gPmNumLinkRxIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The of intervals (seconds) over which the link Rx
statistics have been accumulated."
::= { ocm4gPmEntry 9 }
ocm4gPmLinkRxErrors OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link receive errors."
::= { ocm4gPmEntry 10 }
ocm4gPmLinkRxErredSeconds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link receive errored seconds."
::= { ocm4gPmEntry 11 }
ocm4gPmNumCpeRxIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The of intervals (seconds) over which the CPE Rx
statistics have been accumulated."
::= { ocm4gPmEntry 12 }
ocm4gPmCpeRxErrors OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE receive errors."
::= { ocm4gPmEntry 13 }
ocm4gPmCpeRxErredSeconds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE receive errored seconds."
::= { ocm4gPmEntry 14 }
ocm4gPmNumCpeTxIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The of intervals (seconds) over which the CPE Tx
statistics have been accumulated."
::= { ocm4gPmEntry 15 }
ocm4gPmCpeTxErrors OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE transmit errors."
::= { ocm4gPmEntry 16 }
ocm4gPmCpeTxErredSeconds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE transmit errored seconds."
::= { ocm4gPmEntry 17 }
ocm4gClearPmCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, all PM counters for this
port are reset to zero. A get on this will always
return other"
::= { ocm4gPmEntry 18 }
-- The elements in the oetPerf subgroup of the current subgroup
oetNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OET modules in this time slot (15 minutes)."
::= { oetPerf 1 }
oetPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OetPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OET module."
::= { oetPerf 2 }
oetPerfEntry OBJECT-TYPE
SYNTAX OetPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oetPerfLocation, oetPerfShelf, oetPerfSlot }
::= { oetPerfTable 1 }
OetPerfEntry ::=
SEQUENCE
{
oetPerfLocation CardLocation,
oetPerfShelf CardShelf,
oetPerfSlot INTEGER,
oetPerfState CardState,
oetPerfStatus CardStatus,
oetLastBootTime DateAndTime,
oetAvailTime Counter,
oetErrFreeSecs Counter
}
oetPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { oetPerfEntry 1 }
oetPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { oetPerfEntry 2 }
oetPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { oetPerfEntry 3 }
oetPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the OET module. The states are:
online, offline, empty, loopback or diag."
::= { oetPerfEntry 4 }
oetPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the OET module. This status represents
the status of the OET module and in general is
different from the status of the system."
::= { oetPerfEntry 5 }
oetLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { oetPerfEntry 6 }
oetAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { oetPerfEntry 7 }
oetErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this module has not experienced any alarms."
::= { oetPerfEntry 8 }
oetPmLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF OetPmLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the OET Link ports."
::= { oetPerf 3 }
oetPmLinkEntry OBJECT-TYPE
SYNTAX OetPmLinkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oetPmLinkLocation, oetPmLinkShelf, oetPmLinkSlot, oetPmLink }
::= { oetPmLinkTable 1 }
OetPmLinkEntry ::=
SEQUENCE
{
oetPmLinkLocation CardLocation,
oetPmLinkShelf CardShelf,
oetPmLinkSlot CardSlot,
oetPmLink INTEGER,
oetPmLinkNumIntervals INTEGER,
oetPmLinkRxPwr DisplayString,
oetPmLinkRxBytes DisplayString,
oetPmLinkRxFcsErrs DisplayString,
oetPmLinkTxPwr DisplayString,
oetPmLinkTxTemp DisplayString,
oetPmLinkTxBytes DisplayString,
oetPmLinkFecTx DisplayString,
oetPmLinkFecCorrected1s INTEGER,
oetPmLinkFecCorrected0s INTEGER,
oetPmLinkFecCorrectedBit INTEGER,
oetPmLinkFecCorrectedByte INTEGER,
oetPmLinkFecUncorrectedByte INTEGER,
oetPmLinkFecBlock INTEGER
}
oetPmLinkLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OET card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OET cards."
::= { oetPmLinkEntry 1 }
oetPmLinkShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OET
cards."
::= { oetPmLinkEntry 2 }
oetPmLinkSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OET cards."
::= { oetPmLinkEntry 3 }
oetPmLink OBJECT-TYPE
SYNTAX INTEGER { linkA(11), linkB(12) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The link for which the statistics are for."
::= { oetPmLinkEntry 4 }
oetPmLinkNumIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The of intervals (seconds) over which the link
statistics have been accumulated."
::= { oetPmLinkEntry 5 }
oetPmLinkRxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link receive power."
::= { oetPmLinkEntry 6 }
oetPmLinkRxBytes OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link Rx Bytes."
::= { oetPmLinkEntry 7 }
oetPmLinkRxFcsErrs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link Rx FCS Errors."
::= { oetPmLinkEntry 8 }
oetPmLinkTxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link Tx power."
::= { oetPmLinkEntry 9 }
oetPmLinkTxTemp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pump temp in C"
::= { oetPmLinkEntry 10 }
oetPmLinkTxBytes OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link Tx Bytes."
::= { oetPmLinkEntry 11 }
oetPmLinkFecTx OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FEC Link Tx."
::= { oetPmLinkEntry 12 }
oetPmLinkFecCorrected1s OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FEC Corrected '1's"
::= { oetPmLinkEntry 13 }
oetPmLinkFecCorrected0s OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FEC Corrected '0's"
::= { oetPmLinkEntry 14 }
oetPmLinkFecCorrectedBit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FEC Corrected Bits"
::= { oetPmLinkEntry 15 }
oetPmLinkFecCorrectedByte OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FEC Corrected Bytes"
::= { oetPmLinkEntry 16 }
oetPmLinkFecUncorrectedByte OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FEC Uncorrected Bytes"
::= { oetPmLinkEntry 17 }
oetPmLinkFecBlock OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FEC Block Number"
::= { oetPmLinkEntry 18 }
oetPmPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF OetPmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the OET CPE ports."
::= { oetPerf 4 }
oetPmPortEntry OBJECT-TYPE
SYNTAX OetPmPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oetPmPortLocation, oetPmPortShelf, oetPmPortSlot, oetPmPortIndex }
::= { oetPmPortTable 1 }
OetPmPortEntry ::=
SEQUENCE
{
oetPmPortLocation CardLocation,
oetPmPortShelf CardShelf,
oetPmPortSlot CardSlot,
oetPmPortIndex INTEGER,
oetPmPortNumIntervals INTEGER,
oetPmPortRxPwr DisplayString,
oetPmPortRxBytes DisplayString,
oetPmPortRxFcsErrs DisplayString,
oetPmPortTxPwr DisplayString,
oetPmPortTxTemp DisplayString,
oetPmPortTxBytes DisplayString
}
oetPmPortLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the OET card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
OET cards."
::= { oetPmPortEntry 1 }
oetPmPortShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) OET
cards."
::= { oetPmPortEntry 2 }
oetPmPortSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. Valid
values are: 1 to 17. The system automatically
determines the right value for this entry based
on the known (available) OET cards."
::= { oetPmPortEntry 3 }
oetPmPortIndex OBJECT-TYPE
SYNTAX INTEGER { cpe(1), cpe(2), cpe(3), cpe(4), cpe(5),
cpe(6), cpe(7), cpe(8), cpe(9), cpe(10)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port for which the statistics are for."
::= { oetPmPortEntry 4 }
oetPmPortNumIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The of intervals (seconds) over which the port
statistics have been accumulated."
::= { oetPmPortEntry 5 }
oetPmPortRxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port receive power."
::= { oetPmPortEntry 6 }
oetPmPortRxBytes OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Rx Bytes."
::= { oetPmPortEntry 7 }
oetPmPortRxFcsErrs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Rx FCS Errors."
::= { oetPmPortEntry 8 }
oetPmPortTxPwr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Link Tx power."
::= { oetPmPortEntry 9 }
oetPmPortTxTemp OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Pump temp in C"
::= { oetPmPortEntry 10 }
oetPmPortTxBytes OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Port Tx Bytes."
::= { oetPmPortEntry 11 }
-- The elements in the systemHist subgroup of the historical subgroup
sysHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the overall system"
::= { systemHist 1 }
sysHistEntry OBJECT-TYPE
SYNTAX SysHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { sysHMode }
::= { sysHistTable 1 }
SysHistEntry ::=
SEQUENCE
{
sysHMode HistoryMode,
sysHLastBootTime DateAndTime,
sysHAvailTime Counter,
sysHErrFreeSecs Counter
}
sysHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { sysHistEntry 1 }
sysHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last system boot. This time
represents the boot time of a CP card. It is also
anonymous with the power-up cycle of the chassis."
::= { sysHistEntry 2 }
sysHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds since the system has been up
and running. The criteria for the system
available time is having at least one CP
running with atmost non-service affecting minor
alarm system status"
::= { sysHistEntry 3 }
sysHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that the device has not
experienced any alarms. This counter is across all
cards in the chassis. The system must be in Normal
status for this counter to be incremented."
::= { sysHistEntry 4 }
-- The elements in the downloadHist subgroup of the historical subgroup
dlHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF DlHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the download process"
::= { downloadHist 1 }
dlHistEntry OBJECT-TYPE
SYNTAX DlHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dlHMode }
::= { dlHistTable 1 }
DlHistEntry ::=
SEQUENCE
{
dlHMode HistoryMode,
dlHOkDownloads Counter,
dlHBadDownloads Counter,
dlHLongestTime Gauge,
dlHLongestSize Gauge
}
dlHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { dlHistEntry 1 }
dlHOkDownloads OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of successful downloads"
::= { dlHistEntry 2 }
dlHBadDownloads OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of failed downloads"
::= { dlHistEntry 3 }
dlHLongestTime OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Longest time for any download, in seconds"
::= { dlHistEntry 4 }
dlHLongestSize OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Longest download size for any download, in bytes"
::= { dlHistEntry 5 }
-- The elements in the cpHist subgroup of the historical subgroup
cpHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the communication card"
::= { cpHist 1 }
cpHistEntry OBJECT-TYPE
SYNTAX CpHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpHMode }
::= { cpHistTable 1 }
CpHistEntry ::=
SEQUENCE
{
cpHMode HistoryMode,
cpHNumEvents Counter,
cpHTrapsSent Counter,
cpHSNMPCmdsRcvd Counter
}
cpHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { cpHistEntry 1 }
cpHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received by the active CP"
::= { cpHistEntry 2 }
cpHTrapsSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of traps sent by the active CP"
::= { cpHistEntry 3 }
cpHSNMPCmdsRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of SNMP commands received by the active
CP."
::= { cpHistEntry 4 }
cpHCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpHCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters. It is only
applicable to the active MPM card."
::= { cpHist 2 }
cpHCntrEntry OBJECT-TYPE
SYNTAX CpHCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpHCntrMode, cpCntrShelf, cpCntrSlot, cpCntrType }
::= { cpHCntrTable 1 }
CpHCntrEntry ::=
SEQUENCE
{
cpHCntrMode HistoryMode,
cpHCntrShelf CardShelf,
cpHCntrSlot INTEGER,
cpHCntrType INTEGER,
cpHTotPktSent Counter,
cpHTotPktRcvd Counter,
cpHBadPktRcvd Counter,
cpHTotBadTrans Counter,
cpHBytesSent Counter,
cpHBytesRcvd Counter,
cpHMsgsDlvrd Counter,
cpHBufAllocFail Counter,
cpHEcbAllocFail Counter
}
cpHCntrMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { cpHCntrEntry 1 }
cpHCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10.
The system automatically determines the right value
for this entry based on the value of the current
active CP card."
::= { cpHCntrEntry 2 }
cpHCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right value
for this entry based on the value of the current
active CP card."
::= { cpHCntrEntry 3 }
cpHCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { cpHCntrEntry 4 }
cpHTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { cpHCntrEntry 5 }
cpHTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { cpHCntrEntry 6 }
cpHBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { cpHCntrEntry 7 }
cpHTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { cpHCntrEntry 8 }
cpHBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { cpHCntrEntry 9 }
cpHBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { cpHCntrEntry 10 }
cpHMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { cpHCntrEntry 11 }
cpHBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { cpHCntrEntry 12 }
cpHEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { cpHCntrEntry 13 }
cpHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each communication processor"
::= { cpHist 3 }
cpHHistEntry OBJECT-TYPE
SYNTAX CpHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpHHistMode, cpHHistShelf, cpHHistSlot }
::= { cpHHistTable 1 }
CpHHistEntry ::=
SEQUENCE
{
cpHHistMode HistoryMode,
cpHHistShelf CardShelf,
cpHHistSlot INTEGER,
cpHLastBootTime DateAndTime,
cpHAvailTime Counter,
cpHErrFreeSecs Counter
}
cpHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { cpHHistEntry 1 }
cpHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { cpHHistEntry 2 }
cpHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { cpHHistEntry 3 }
cpHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this CP."
::= { cpHHistEntry 4 }
cpHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this CP has been up and
running."
::= { cpHHistEntry 5 }
cpHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this CP has not
experienced any alarms."
::= { cpHHistEntry 6 }
-- The elements in the ccHist subgroup of the historical subgroup
ccHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the channel card"
::= { ccHist 1 }
ccHistEntry OBJECT-TYPE
SYNTAX CcHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccHMode }
::= { ccHistTable 1 }
CcHistEntry ::=
SEQUENCE
{
ccHMode HistoryMode,
ccHNumEvents Counter
}
ccHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ccHistEntry 1 }
ccHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received for all CC's"
::= { ccHistEntry 2 }
ccHCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcHCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ccHist 2 }
ccHCntrEntry OBJECT-TYPE
SYNTAX CcHCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccHCntrMode, ccHCntrLocation, ccHCntrShelf,
ccHCntrSlot, ccHCntrType }
::= { ccHCntrTable 1 }
CcHCntrEntry ::=
SEQUENCE
{
ccHCntrMode HistoryMode,
ccHCntrLocation CardLocation,
ccHCntrShelf CardShelf,
ccHCntrSlot INTEGER,
ccHCntrType INTEGER,
ccHTotPktSent Counter,
ccHTotPktRcvd Counter,
ccHBadPktRcvd Counter,
ccHTotBadTrans Counter,
ccHBytesSent Counter,
ccHBytesRcvd Counter,
ccHMsgsDlvrd Counter,
ccHBufAllocFail Counter,
ccHEcbAllocFail Counter
}
ccHCntrMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ccHCntrEntry 1 }
ccHCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the CC card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
CC cards."
::= { ccHCntrEntry 2 }
ccHCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10.
The system automatically determines the right value
for this entry based on the known (available) CC
cards."
::= { ccHCntrEntry 3 }
ccHCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right value
for this entry based on the known (available)
CC cards."
::= { ccHCntrEntry 4 }
ccHCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), iwm(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { ccHCntrEntry 5 }
ccHTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { ccHCntrEntry 6 }
ccHTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { ccHCntrEntry 7 }
ccHBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { ccHCntrEntry 8 }
ccHTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { ccHCntrEntry 9 }
ccHBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { ccHCntrEntry 10 }
ccHBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { ccHCntrEntry 11 }
ccHMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { ccHCntrEntry 12 }
ccHBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { ccHCntrEntry 13 }
ccHEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { ccHCntrEntry 14 }
ccHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each channel card"
::= { ccHist 3 }
ccHHistEntry OBJECT-TYPE
SYNTAX CcHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccHHistMode, ccHHistLocation, ccHHistShelf,
ccHHistSlot }
::= { ccHHistTable 1 }
CcHHistEntry ::=
SEQUENCE
{
ccHHistMode HistoryMode,
ccHHistLocation CardLocation,
ccHHistShelf CardShelf,
ccHHistSlot INTEGER,
ccHLastBootTime DateAndTime,
ccHAvailTime Counter,
ccHErrFreeSecs Counter
}
ccHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ccHHistEntry 1 }
ccHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card. Valid choices are Local
or Remote. The system automatically selects this
value based on the known (available) CC cards."
::= { ccHHistEntry 2 }
ccHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { ccHHistEntry 3 }
ccHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { ccHHistEntry 4 }
ccHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { ccHHistEntry 5 }
ccHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this CC has been up and
running."
::= { ccHHistEntry 6 }
ccHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this CC has not experienced
any alarms."
::= { ccHHistEntry 7 }
-- The elements in the muxHist subgroup of the historical subgroup
muxHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the mux/demux card"
::= { muxHist 1 }
muxHistEntry OBJECT-TYPE
SYNTAX MuxHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { muxHMode }
::= { muxHistTable 1 }
MuxHistEntry ::=
SEQUENCE
{
muxHMode HistoryMode,
muxHNumEvents Counter
}
muxHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { muxHistEntry 1 }
muxHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
MUX's."
::= { muxHistEntry 2 }
muxHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each mux/demux card"
::= { muxHist 2 }
muxHHistEntry OBJECT-TYPE
SYNTAX MuxHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { muxHHistMode, muxHHistLocation, muxHHistShelf,
muxHHistSlot }
::= { muxHHistTable 1 }
MuxHHistEntry ::=
SEQUENCE
{
muxHHistMode HistoryMode,
muxHHistLocation CardLocation,
muxHHistShelf CardShelf,
muxHHistSlot INTEGER,
muxHHistType INTEGER,
muxHLastBootTime DateAndTime,
muxHAvailTime Counter,
muxHErrFreeSecs Counter
}
muxHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { muxHHistEntry 1 }
muxHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { muxHHistEntry 2 }
muxHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { muxHHistEntry 3 }
muxHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { muxHHistEntry 4 }
muxHHistType OBJECT-TYPE
SYNTAX INTEGER { mux(4), demux(5), w4cd(10), w2cmd(13), w4cm(21)}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the mux. The choices are: mux or demux."
::= { muxHHistEntry 5 }
muxHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { muxHHistEntry 6 }
muxHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this Mux has been up and
running."
::= { muxHHistEntry 7 }
muxHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this mux has not
experienced any alarms."
::= { muxHHistEntry 8 }
-- The elements in the psHist subgroup of the historical subgroup
psHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF PsHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the power supply card"
::= { psHist 1 }
psHistEntry OBJECT-TYPE
SYNTAX PsHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { psHMode }
::= { psHistTable 1 }
PsHistEntry ::=
SEQUENCE
{
psHMode HistoryMode,
psHNumEvents Counter
}
psHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { psHistEntry 1 }
psHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
Power Supplies."
::= { psHistEntry 2 }
-- The elements in the fadmHist subgroup of the historical subgroup
fadmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF FadmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the fadm card"
::= { fadmHist 1 }
fadmHistEntry OBJECT-TYPE
SYNTAX FadmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fadmHMode }
::= { fadmHistTable 1 }
FadmHistEntry ::=
SEQUENCE
{
fadmHMode HistoryMode,
fadmHNumEvents Counter
}
fadmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { fadmHistEntry 1 }
fadmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
FADM's."
::= { fadmHistEntry 2 }
fadmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF FadmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each fadm card"
::= { fadmHist 2 }
fadmHHistEntry OBJECT-TYPE
SYNTAX FadmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fadmHHistMode, fadmHHistLocation, fadmHHistShelf,
fadmHHistSlot }
::= { fadmHHistTable 1 }
FadmHHistEntry ::=
SEQUENCE
{
fadmHHistMode HistoryMode,
fadmHHistLocation CardLocation,
fadmHHistShelf CardShelf,
fadmHHistSlot INTEGER,
fadmHLastBootTime DateAndTime,
fadmHAvailTime Counter,
fadmHErrFreeSecs Counter
}
fadmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { fadmHHistEntry 1 }
fadmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { fadmHHistEntry 2 }
fadmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { fadmHHistEntry 3 }
fadmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { fadmHHistEntry 4 }
fadmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { fadmHHistEntry 6 }
fadmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this Mux has been up and
running."
::= { fadmHHistEntry 7 }
fadmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this mux has not
experienced any alarms."
::= { fadmHHistEntry 8 }
-- The elements in the oppmHist subgroup of the historical subgroup
oppmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF OppmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the oppm card"
::= { oppmHist 1 }
oppmHistEntry OBJECT-TYPE
SYNTAX OppmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oppmHMode }
::= { oppmHistTable 1 }
OppmHistEntry ::=
SEQUENCE
{
oppmHMode HistoryMode,
oppmHNumEvents Counter
}
oppmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { oppmHistEntry 1 }
oppmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OPPM's."
::= { oppmHistEntry 2 }
oppmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF OppmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each fadm card"
::= { oppmHist 2 }
oppmHHistEntry OBJECT-TYPE
SYNTAX OppmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oppmHHistMode, oppmHHistLocation, oppmHHistShelf,
oppmHHistSlot }
::= { oppmHHistTable 1 }
OppmHHistEntry ::=
SEQUENCE
{
oppmHHistMode HistoryMode,
oppmHHistLocation CardLocation,
oppmHHistShelf CardShelf,
oppmHHistSlot INTEGER,
oppmHLastBootTime DateAndTime,
oppmHAvailTime Counter,
oppmHErrFreeSecs Counter
}
oppmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { oppmHHistEntry 1 }
oppmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { oppmHHistEntry 2 }
oppmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { oppmHHistEntry 3 }
oppmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { oppmHHistEntry 4 }
oppmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { oppmHHistEntry 6 }
oppmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds that this Mux has been up and
running."
::= { oppmHHistEntry 7 }
oppmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds that this mux has not
experienced any alarms."
::= { oppmHHistEntry 8 }
-- The elements in the mcmHist subgroup of the historical subgroup
mcmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the channel card"
::= { mcmHist 1 }
mcmHistEntry OBJECT-TYPE
SYNTAX McmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmHMode }
::= { mcmHistTable 1 }
McmHistEntry ::=
SEQUENCE
{
mcmHMode HistoryMode,
mcmHNumEvents Counter
}
mcmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { mcmHistEntry 1 }
mcmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received for all mcmt1's/mcme1's"
::= { mcmHistEntry 2 }
mcmHCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmHCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { mcmHist 2 }
mcmHCntrEntry OBJECT-TYPE
SYNTAX McmHCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmHCntrMode, mcmHCntrLocation, mcmHCntrShelf,
mcmHCntrSlot, mcmHCntrType }
::= { mcmHCntrTable 1 }
McmHCntrEntry ::=
SEQUENCE
{
mcmHCntrMode HistoryMode,
mcmHCntrLocation CardLocation,
mcmHCntrShelf CardShelf,
mcmHCntrSlot INTEGER,
mcmHCntrType INTEGER,
mcmHTotPktSent Counter,
mcmHTotPktRcvd Counter,
mcmHBadPktRcvd Counter,
mcmHTotBadTrans Counter,
mcmHBytesSent Counter,
mcmHBytesRcvd Counter,
mcmHMsgsDlvrd Counter,
mcmHBufAllocFail Counter,
mcmHEcbAllocFail Counter
}
mcmHCntrMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { mcmHCntrEntry 1 }
mcmHCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the mcm/mcme1 card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
mcmt1/mcme1 cards."
::= { mcmHCntrEntry 2 }
mcmHCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 3.
The system automatically determines the right value
for this entry based on the known (available) mcmt1/mcme1
cards."
::= { mcmHCntrEntry 3 }
mcmHCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right
value for this entry based on the known
(available) mcmt1/mcme1 cards."
::= { mcmHCntrEntry 4 }
mcmHCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), iwm(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { mcmHCntrEntry 5 }
mcmHTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { mcmHCntrEntry 6 }
mcmHTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { mcmHCntrEntry 7 }
mcmHBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { mcmHCntrEntry 8 }
mcmHTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { mcmHCntrEntry 9 }
mcmHBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { mcmHCntrEntry 10 }
mcmHBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { mcmHCntrEntry 11 }
mcmHMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { mcmHCntrEntry 12 }
mcmHBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { mcmHCntrEntry 13 }
mcmHEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { mcmHCntrEntry 14 }
-- port entries
mcmPortHIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmPortHIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the mcmt1/mcme1 port counters."
::= { mcmHist 3 }
mcmPortHIntervalEntry OBJECT-TYPE
SYNTAX McmPortHIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmPortHIntervalLocation, mcmPortHIntervalShelf,
mcmPortHIntervalSlot, mcmPortHIntervalPort,
mcmPortHIntervalNumber }
::= { mcmPortHIntervalTable 1 }
McmPortHIntervalEntry ::=
SEQUENCE
{
mcmPortHIntervalLocation CardLocation,
mcmPortHIntervalShelf CardShelf,
mcmPortHIntervalSlot INTEGER,
mcmPortHIntervalPort INTEGER,
mcmPortHIntervalNumber INTEGER,
mcmPortHIntervalASs Counter,
mcmPortHIntervalFrameASs Counter,
mcmPortHIntervalFEs Counter,
mcmPortHIntervalCRCErrs Counter,
mcmPortHIntervalSESs Counter,
mcmPortHIntervalSEFSs Counter,
mcmPortHIntervalUASs Counter,
mcmPortHIntervalLESs Counter,
mcmPortHIntervalBESs Counter,
mcmPortHIntervalDMs Counter,
mcmPortHIntervalLCVs Counter
}
mcmPortHIntervalLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the mcm/mcme1 card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
mcm/mcme1 cards."
::= { mcmPortHIntervalEntry 1 }
mcmPortHIntervalShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 3.
The system automatically determines the right value
for this entry based on the known (available) mcmt1/mcme1
cards."
::= { mcmPortHIntervalEntry 2 }
mcmPortHIntervalSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right value
for this entry based on the known (available)
mcmt1/mcme1 cards."
::= { mcmPortHIntervalEntry 3 }
mcmPortHIntervalPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port within the shelf the card is in. Valid
values are: 1 to 4. The system automatically
determines the right value for this entry based
on the known (available) mcmt1/mcme1 cards."
::= { mcmPortHIntervalEntry 4 }
mcmPortHIntervalNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Interval number of the ds1 port. Valid
values are: 1 to 96. The system automatically
determines the right value for this entry based
on the known (available) interval number."
::= { mcmPortHIntervalEntry 5 }
mcmPortHIntervalASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's ASs counter for specific interval."
::= { mcmPortHIntervalEntry 6 }
mcmPortHIntervalFrameASs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's FrameASs counter for specific interval."
::= { mcmPortHIntervalEntry 7 }
mcmPortHIntervalFEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's FEs counter for specific interval."
::= { mcmPortHIntervalEntry 8 }
mcmPortHIntervalCRCErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's CRC errs counter for specific interval."
::= { mcmPortHIntervalEntry 9 }
mcmPortHIntervalSESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's SESs counter less than 15 mins."
::= { mcmPortHIntervalEntry 10 }
mcmPortHIntervalSEFSs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's SEFSs counter less than 15 mins."
::= { mcmPortHIntervalEntry 11 }
mcmPortHIntervalUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's UASs counter less than 15 mins."
::= { mcmPortHIntervalEntry 12 }
mcmPortHIntervalLESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's LESs counter less than 15 mins."
::= { mcmPortHIntervalEntry 13 }
mcmPortHIntervalBESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's BESs counter less than 15 mins."
::= { mcmPortHIntervalEntry 14 }
mcmPortHIntervalDMs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's DMSs counter less than 15 mins."
::= { mcmPortHIntervalEntry 15 }
mcmPortHIntervalLCVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's LCVs counter less than 15 mins."
::= { mcmPortHIntervalEntry 16 }
-- 24 hr total port entries
mcmPortHTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmPortHTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the mcmt1/mcme1 port counters."
::= { mcmHist 4 }
mcmPortHTotalEntry OBJECT-TYPE
SYNTAX McmPortHTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmPortHTotalLocation, mcmPortHTotalShelf,
mcmPortHTotalSlot, mcmPortHTotalPort }
::= { mcmPortHTotalTable 1 }
McmPortHTotalEntry ::=
SEQUENCE
{
mcmPortHTotalLocation CardLocation,
mcmPortHTotalShelf CardShelf,
mcmPortHTotalSlot INTEGER,
mcmPortHTotalPort INTEGER,
mcmPortHTotalASs Counter,
mcmPortHTotalFrameASs Counter,
mcmPortHTotalFEs Counter,
mcmPortHTotalCRCErrs Counter,
mcmPortHTotalSESs Counter,
mcmPortHTotalSEFSs Counter,
mcmPortHTotalUASs Counter,
mcmPortHTotalLESs Counter,
mcmPortHTotalBESs Counter,
mcmPortHTotalDMs Counter,
mcmPortHTotalLCVs Counter
}
mcmPortHTotalLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the mcm card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
mcm/mcme1 cards."
::= { mcmPortHTotalEntry 1 }
mcmPortHTotalShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 3.
The system automatically determines the right value
for this entry based on the known (available) mcmt1/mcme1
cards."
::= { mcmPortHTotalEntry 2 }
mcmPortHTotalSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right
value for this entry based on the known
(available) mcmt1/mcme1 cards."
::= { mcmPortHTotalEntry 3 }
mcmPortHTotalPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port within the shelf the card is in. Valid
values are: 1 to 4. The system automatically
determines the right value for this entry based
on the known (available) mcmt1/mcme1 cards."
::= { mcmPortHTotalEntry 4 }
mcmPortHTotalASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's ASs counter for the last 24 hrs."
::= { mcmPortHTotalEntry 5 }
mcmPortHTotalFrameASs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's FrameASs counter for the last 24 hrs."
::= { mcmPortHTotalEntry 6 }
mcmPortHTotalFEs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's FEs counter for the last 24 hrs."
::= { mcmPortHTotalEntry 7 }
mcmPortHTotalCRCErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's CRC errs counter for the last 24 hrs."
::= { mcmPortHTotalEntry 8 }
mcmPortHTotalSESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's SESs counter less than 15 mins."
::= { mcmPortHTotalEntry 9 }
mcmPortHTotalSEFSs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's SEFSs counter less than 15 mins."
::= { mcmPortHTotalEntry 10 }
mcmPortHTotalUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's UASs counter less than 15 mins."
::= { mcmPortHTotalEntry 11 }
mcmPortHTotalLESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's LESs counter less than 15 mins."
::= { mcmPortHTotalEntry 12 }
mcmPortHTotalBESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's BESs counter less than 15 mins."
::= { mcmPortHTotalEntry 13 }
mcmPortHTotalDMs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's DMSs counter less than 15 mins."
::= { mcmPortHTotalEntry 14 }
mcmPortHTotalLCVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMT1/MCME1 port's LCVs counter less than 15 mins."
::= { mcmPortHTotalEntry 15 }
-- The elements in the fnHist subgroup of the historical subgroup
fnHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF FnHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the fan modules"
::= { fnHist 1 }
fnHistEntry OBJECT-TYPE
SYNTAX FnHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fnHMode }
::= { fnHistTable 1 }
FnHistEntry ::=
SEQUENCE
{
fnHMode HistoryMode,
fnHNumEvents Counter
}
fnHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { fnHistEntry 1 }
fnHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
fan modules."
::= { fnHistEntry 2 }
-- The elements in the csimHist subgroup of the historical subgroup
csimHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF CsimHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the ColorSIM "
::= { csimHist 1 }
csimHistEntry OBJECT-TYPE
SYNTAX CsimHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { csimHMode }
::= { csimHistTable 1 }
CsimHistEntry ::=
SEQUENCE
{
csimHMode HistoryMode,
csimHNumEvents Counter
}
csimHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm. The reason this has been made obsolete
is that all colorsim related events would eventually be part
of ocm events"
::= { csimHistEntry 1 }
csimHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable keeps track of the number of events
related to ColorSIM. The reason this has been made obsolete
is that all colorsim related events would eventually be part
of ocm events"
::= { csimHistEntry 2 }
csimHistIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF CsimHistIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
colorsim card."
::= { csimHist 2 }
csimHistIntervalEntry OBJECT-TYPE
SYNTAX CsimHistIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { csimIntervalLocation, csimIntervalShelf,
csimIntervalSlot, csimIntervalNumber }
::= { csimHistIntervalTable 1 }
CsimHistIntervalEntry ::=
SEQUENCE
{
csimIntervalLocation CardLocation,
csimIntervalShelf CardShelf,
csimIntervalSlot INTEGER,
csimIntervalNumber INTEGER,
csimIntervalEFIs INTEGER,
csimIntervalEIs INTEGER,
csimIntervalSEIs INTEGER,
csimIntervalBERs DisplayString,
csimIntervalUAIs INTEGER,
csimIntervalValidData Boolean,
csimIntervalDateTime INTEGER
}
csimIntervalLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
" Location of the ColorSIM module"
::= { csimHistIntervalEntry 1 }
csimIntervalShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf of the ColorSIM module"
::= { csimHistIntervalEntry 2 }
csimIntervalSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Slot of the ColorSIM module"
::= { csimHistIntervalEntry 3 }
csimIntervalNumber OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates the interval for which
the set of statistics data is available."
::= { csimHistIntervalEntry 4 }
csimIntervalEFIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Error Free
Interval Counts in this interval."
::= { csimHistIntervalEntry 5 }
csimIntervalEIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Errored
Interval Counts in this interval."
::= { csimHistIntervalEntry 6 }
csimIntervalSEIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Severely
Errored Interval Counts in this interval."
::= { csimHistIntervalEntry 7 }
csimIntervalBERs OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Bit
Error Rate Counts in this interval. The unit
is in the form of x.ye-z."
::= { csimHistIntervalEntry 8 }
csimIntervalUAIs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The counter associated with the number of Unavailable
Interval Counts in this interval."
::= { csimHistIntervalEntry 9 }
csimIntervalValidData OBJECT-TYPE
SYNTAX Boolean
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable indicates if the data for this interval
is valid. Not supported"
::= { csimHistIntervalEntry 10 }
csimIntervalDateTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time in seconds elasped since 01/01/1970 00:00:00 GMT for this interval.
Assuming local time is same as GMT"
::= { csimHistIntervalEntry 11 }
-- The elements in the rpsmHist subgroup of the historical subgroup
rpsmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpsmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the rpsm card"
::= { rpsmHist 1 }
rpsmHistEntry OBJECT-TYPE
SYNTAX RpsmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oppmHMode }
::= { rpsmHistTable 1 }
RpsmHistEntry ::=
SEQUENCE
{
rpsmHMode HistoryMode,
rpsmHNumEvents Counter
}
rpsmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { rpsmHistEntry 1 }
rpsmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RPSM's."
::= { rpsmHistEntry 2 }
rpsmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpsmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rpsm card"
::= { rpsmHist 2 }
rpsmHHistEntry OBJECT-TYPE
SYNTAX RpsmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rpsmHHistMode, rpsmHHistLocation, rpsmHHistShelf,
rpsmHHistSlot }
::= { rpsmHHistTable 1 }
RpsmHHistEntry ::=
SEQUENCE
{
rpsmHHistMode HistoryMode,
rpsmHHistLocation CardLocation,
rpsmHHistShelf CardShelf,
rpsmHHistSlot INTEGER,
rpsmHLastBootTime DateAndTime,
rpsmHAvailTime Counter,
rpsmHErrFreeSecs Counter
}
rpsmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { rpsmHHistEntry 1 }
rpsmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { rpsmHHistEntry 2 }
rpsmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { rpsmHHistEntry 3 }
rpsmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rpsmHHistEntry 4 }
rpsmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { rpsmHHistEntry 6 }
rpsmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds that this rpsm has been up and
running."
::= { rpsmHHistEntry 7 }
rpsmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds that this rpsm has not
experienced any alarms."
::= { rpsmHHistEntry 8 }
-- The elements in the rsdmHist subgroup of the historical subgroup
rsdmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsdmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the rsdm card"
::= { rsdmHist 1 }
rsdmHistEntry OBJECT-TYPE
SYNTAX RsdmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsdmHMode }
::= { rsdmHistTable 1 }
RsdmHistEntry ::=
SEQUENCE
{
rsdmHMode HistoryMode,
rsdmHNumEvents Counter
}
rsdmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { rsdmHistEntry 1 }
rsdmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RSDM's."
::= { rsdmHistEntry 2 }
rsdmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsdmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rsdm card."
::= { rsdmHist 2 }
rsdmHHistEntry OBJECT-TYPE
SYNTAX RsdmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsdmHHistMode, rsdmHHistLocation, rsdmHHistShelf,
rsdmHHistSlot }
::= {rsdmHHistTable 1 }
RsdmHHistEntry ::=
SEQUENCE
{
rsdmHHistMode HistoryMode,
rsdmHHistLocation CardLocation,
rsdmHHistShelf CardShelf,
rsdmHHistSlot INTEGER,
rsdmHLastBootTime DateAndTime,
rsdmHAvailTime Counter,
rsdmHErrFreeSecs Counter
}
rsdmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { rsdmHHistEntry 1 }
rsdmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { rsdmHHistEntry 2 }
rsdmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { rsdmHHistEntry 3 }
rsdmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rsdmHHistEntry 4 }
rsdmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { rsdmHHistEntry 6 }
rsdmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds that this rsdm has been up and
running."
::= { rsdmHHistEntry 7 }
rsdmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds that this rsdm has not
experienced any alarms."
::= { rsdmHHistEntry 8 }
-- The elements in the rtdmHist subgroup of the historical subgroup
rtdmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtdmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the rtdm card"
::= { rtdmHist 1 }
rtdmHistEntry OBJECT-TYPE
SYNTAX RtdmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rtdmHMode }
::= { rtdmHistTable 1 }
RtdmHistEntry ::=
SEQUENCE
{
rtdmHMode HistoryMode,
rtdmHNumEvents Counter
}
rtdmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { rtdmHistEntry 1 }
rtdmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
rtdm's."
::= { rtdmHistEntry 2 }
rtdmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtdmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rtdm card."
::= { rtdmHist 2 }
rtdmHHistEntry OBJECT-TYPE
SYNTAX RtdmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rtdmHHistMode, rtdmHHistLocation, rtdmHHistShelf,
rtdmHHistSlot }
::= { rtdmHHistTable 1 }
RtdmHHistEntry ::=
SEQUENCE
{
rtdmHHistMode HistoryMode,
rtdmHHistLocation CardLocation,
rtdmHHistShelf CardShelf,
rtdmHHistSlot INTEGER,
rtdmHLastBootTime DateAndTime,
rtdmHAvailTime Counter,
rtdmHErrFreeSecs Counter
}
rtdmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { rtdmHHistEntry 1 }
rtdmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { rtdmHHistEntry 2 }
rtdmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { rtdmHHistEntry 3 }
rtdmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rtdmHHistEntry 4 }
rtdmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { rtdmHHistEntry 5 }
rtdmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds that this rtdm has been up and
running."
::= { rtdmHHistEntry 6 }
rtdmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds that this rtdm has not
experienced any alarms."
::= { rtdmHHistEntry 7 }
-- The elements in the osamHist subgroup of the historical subgroup
osamHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF OsamHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the osam module."
::= { osamHist 1 }
osamHistEntry OBJECT-TYPE
SYNTAX OsamHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { osamHMode }
::= { osamHistTable 1 }
OsamHistEntry ::=
SEQUENCE
{
osamHMode HistoryMode,
osamHNumEvents Counter
}
osamHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of data collection."
::= { osamHistEntry 1 }
osamHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received for all osam's."
::= { osamHistEntry 2 }
osamHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF OsamHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for
historical performance data collected for each
osam module."
::= { osamHist 2 }
osamHHistEntry OBJECT-TYPE
SYNTAX OsamHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { osamHHistMode, osamHHistLocation, osamHHistShelf,
osamHHistSlot }
::= { osamHHistTable 1 }
OsamHHistEntry ::=
SEQUENCE
{
osamHHistMode HistoryMode,
osamHHistLocation CardLocation,
osamHHistShelf CardShelf,
osamHHistSlot INTEGER,
osamHHistLastBootTime DateAndTime,
osamHHistAvailTime Counter,
osamHHistErrFreeSecs Counter
}
osamHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection."
::= { osamHHistEntry 1 }
osamHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { osamHHistEntry 2 }
osamHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf number in which the module is plugged in."
::= { osamHHistEntry 3 }
osamHHistSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number in which the module is plugged in."
::= { osamHHistEntry 4 }
osamHHistLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { osamHHistEntry 5 }
osamHHistAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds since the start of this
historical mode that this module has been up and
running."
::= { osamHHistEntry 6 }
osamHHistErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds since the start of this
historical mode that this module has not experienced
any alarms."
::= { osamHHistEntry 7 }
-- The elements in the rsmHist subgroup of the historical subgroup
rsmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the rsm card"
::= { rsmHist 1 }
rsmHistEntry OBJECT-TYPE
SYNTAX RsmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsmHMode }
::= { rsmHistTable 1 }
RsmHistEntry ::=
SEQUENCE
{
rsmHMode HistoryMode,
rsmHNumEvents Counter
}
rsmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { rsmHistEntry 1 }
rsmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RSM's."
::= { rsmHistEntry 2 }
rsmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rsm card."
::= { rsmHist 2 }
rsmHHistEntry OBJECT-TYPE
SYNTAX RsmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsmHHistMode, rsmHHistLocation, rsmHHistShelf,
rsmHHistSlot }
::= {rsmHHistTable 1 }
RsmHHistEntry ::=
SEQUENCE
{
rsmHHistMode HistoryMode,
rsmHHistLocation CardLocation,
rsmHHistShelf CardShelf,
rsmHHistSlot CardSlot,
rsmHLastBootTime DateAndTime,
rsmHAvailTime Counter,
rsmHErrFreeSecs Counter
}
rsmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { rsmHHistEntry 1 }
rsmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card."
::= { rsmHHistEntry 2 }
rsmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { rsmHHistEntry 3 }
rsmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rsmHHistEntry 4 }
rsmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { rsmHHistEntry 6 }
rsmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this rsm has been up and
running."
::= { rsmHHistEntry 7 }
rsmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this rsm has not
experienced any alarms."
::= { rsmHHistEntry 8 }
-- The elements in the upsmHist subgroup of the historical subgroup
upsmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the upsm card"
::= { upsmHist 1 }
upsmHistEntry OBJECT-TYPE
SYNTAX UpsmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { upsmHMode }
::= { upsmHistTable 1 }
UpsmHistEntry ::=
SEQUENCE
{
upsmHMode HistoryMode,
upsmHNumEvents Counter
}
upsmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { upsmHistEntry 1 }
upsmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
UPSM's."
::= { upsmHistEntry 2 }
upsmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each upsm card."
::= { upsmHist 2 }
upsmHHistEntry OBJECT-TYPE
SYNTAX UpsmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { upsmHHistMode, upsmHHistLocation, upsmHHistShelf,
upsmHHistSlot }
::= {upsmHHistTable 1 }
UpsmHHistEntry ::=
SEQUENCE
{
upsmHHistMode HistoryMode,
upsmHHistLocation CardLocation,
upsmHHistShelf CardShelf,
upsmHHistSlot CardSlot,
upsmHLastBootTime DateAndTime,
upsmHAvailTime Counter,
upsmHErrFreeSecs Counter
}
upsmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { upsmHHistEntry 1 }
upsmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card."
::= { upsmHHistEntry 2 }
upsmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { upsmHHistEntry 3 }
upsmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { upsmHHistEntry 4 }
upsmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this card."
::= { upsmHHistEntry 6 }
upsmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this upsm has been up and
running."
::= { upsmHHistEntry 7 }
upsmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this upsm has not
experienced any alarms."
::= { upsmHHistEntry 8 }
-- The elements in the mcmescHist subgroup of the historical subgroup
mcmescHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the channel card"
::= { mcmescHist 1 }
mcmescHistEntry OBJECT-TYPE
SYNTAX McmescHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescHMode }
::= { mcmescHistTable 1 }
McmescHistEntry ::=
SEQUENCE
{
mcmescHMode HistoryMode,
mcmescHNumEvents Counter
}
mcmescHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or long term."
::= { mcmescHistEntry 1 }
mcmescHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of events received for all mcmesc's"
::= { mcmescHistEntry 2 }
mcmescHCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescHCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { mcmescHist 2 }
mcmescHCntrEntry OBJECT-TYPE
SYNTAX McmescHCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescHCntrMode, mcmescHCntrLocation, mcmescHCntrShelf,
mcmescHCntrSlot, mcmescHCntrType }
::= { mcmescHCntrTable 1 }
McmescHCntrEntry ::=
SEQUENCE
{
mcmescHCntrMode HistoryMode,
mcmescHCntrLocation CardLocation,
mcmescHCntrShelf CardShelf,
mcmescHCntrSlot INTEGER,
mcmescHCntrType INTEGER,
mcmescHTotPktSent Counter,
mcmescHTotPktRcvd Counter,
mcmescHBadPktRcvd Counter,
mcmescHTotBadTrans Counter,
mcmescHBytesSent Counter,
mcmescHBytesRcvd Counter,
mcmescHMsgsDlvrd Counter
}
mcmescHCntrMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or long term."
::= { mcmescHCntrEntry 1 }
mcmescHCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the mcmesc card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
mcmesc cards."
::= { mcmescHCntrEntry 2 }
mcmescHCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) mcmesc
cards."
::= { mcmescHCntrEntry 3 }
mcmescHCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right
value for this entry based on the known
(available) mcmesc cards."
::= { mcmescHCntrEntry 4 }
mcmescHCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), iwm(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { mcmescHCntrEntry 5 }
mcmescHTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { mcmescHCntrEntry 6 }
mcmescHTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { mcmescHCntrEntry 7 }
mcmescHBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { mcmescHCntrEntry 8 }
mcmescHTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { mcmescHCntrEntry 9 }
mcmescHBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { mcmescHCntrEntry 10 }
mcmescHBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { mcmescHCntrEntry 11 }
mcmescHMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { mcmescHCntrEntry 12 }
-- The elements in the tapHist subgroup of the historical subgroup
tapHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF TapHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the TAP module."
::= { tapHist 1 }
tapHistEntry OBJECT-TYPE
SYNTAX TapHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { tapHMode }
::= { tapHistTable 1 }
TapHistEntry ::=
SEQUENCE
{
tapHMode HistoryMode,
tapHNumEvents Counter
}
tapHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { tapHistEntry 1 }
tapHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
TAP modules."
::= { tapHistEntry 2 }
tapHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF TapHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each TAP module"
::= { tapHist 2 }
tapHHistEntry OBJECT-TYPE
SYNTAX TapHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { tapHHistMode, tapHHistLocation, tapHHistShelf,
tapHHistSlot }
::= { tapHHistTable 1 }
TapHHistEntry ::=
SEQUENCE
{
tapHHistMode HistoryMode,
tapHHistLocation CardLocation,
tapHHistShelf CardShelf,
tapHHistSlot INTEGER,
tapHHistType INTEGER,
tapHLastBootTime DateAndTime,
tapHAvailTime Counter,
tapHErrFreeSecs Counter
}
tapHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { tapHHistEntry 1 }
tapHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { tapHHistEntry 2 }
tapHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { tapHHistEntry 3 }
tapHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { tapHHistEntry 4 }
tapHHistType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module type."
::= { tapHHistEntry 5 }
tapHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { tapHHistEntry 6 }
tapHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has been up and
running."
::= { tapHHistEntry 7 }
tapHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has not
experienced any alarms."
::= { tapHHistEntry 8 }
-- The elements in the voadmHist subgroup of the historical subgroup
voadmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoadmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the VOADM module."
::= { voadmHist 1 }
voadmHistEntry OBJECT-TYPE
SYNTAX VoadmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { voadmHMode }
::= { voadmHistTable 1 }
VoadmHistEntry ::=
SEQUENCE
{
voadmHMode HistoryMode,
voadmHNumEvents Counter
}
voadmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { voadmHistEntry 1 }
voadmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
VOADM modules."
::= { voadmHistEntry 2 }
voadmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF VoadmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each VOADM module"
::= { voadmHist 2 }
voadmHHistEntry OBJECT-TYPE
SYNTAX VoadmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { voadmHHistMode, voadmHHistLocation, voadmHHistShelf,
voadmHHistSlot }
::= { voadmHHistTable 1 }
VoadmHHistEntry ::=
SEQUENCE
{
voadmHHistMode HistoryMode,
voadmHHistLocation CardLocation,
voadmHHistShelf CardShelf,
voadmHHistSlot INTEGER,
voadmHHistType INTEGER,
voadmHLastBootTime DateAndTime,
voadmHAvailTime Counter,
voadmHErrFreeSecs Counter
}
voadmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { voadmHHistEntry 1 }
voadmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { voadmHHistEntry 2 }
voadmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { voadmHHistEntry 3 }
voadmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { voadmHHistEntry 4 }
voadmHHistType OBJECT-TYPE
SYNTAX CardType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module type."
::= { voadmHHistEntry 5 }
voadmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { voadmHHistEntry 6 }
voadmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has been up and
running."
::= { voadmHHistEntry 7 }
voadmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has not
experienced any alarms."
::= { voadmHHistEntry 8 }
-- The elements in the dmmHist subgroup of the historical subgroup
dmmHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the DMM module."
::= { dmmHist 1 }
dmmHistEntry OBJECT-TYPE
SYNTAX DmmHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dmmHMode }
::= { dmmHistTable 1 }
DmmHistEntry ::=
SEQUENCE
{
dmmHMode HistoryMode,
dmmHNumEvents Counter
}
dmmHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { dmmHistEntry 1 }
dmmHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
DMM modules."
::= { dmmHistEntry 2 }
dmmHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF DmmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each DMM module"
::= { dmmHist 2 }
dmmHHistEntry OBJECT-TYPE
SYNTAX DmmHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { dmmHHistMode, dmmHHistLocation, dmmHHistShelf,
dmmHHistSlot }
::= { dmmHHistTable 1 }
DmmHHistEntry ::=
SEQUENCE
{
dmmHHistMode HistoryMode,
dmmHHistLocation CardLocation,
dmmHHistShelf CardShelf,
dmmHHistSlot INTEGER,
dmmHLastBootTime DateAndTime,
dmmHAvailTime Counter,
dmmHErrFreeSecs Counter
}
dmmHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { dmmHHistEntry 1 }
dmmHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { dmmHHistEntry 2 }
dmmHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { dmmHHistEntry 3 }
dmmHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { dmmHHistEntry 4 }
dmmHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { dmmHHistEntry 5 }
dmmHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has been up and
running."
::= { dmmHHistEntry 6 }
dmmHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has not
experienced any alarms."
::= { dmmHHistEntry 7 }
-- The elements in the ocm10gfHist subgroup of the historical subgroup
ocm10gfHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm10gfHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the OCM10GF module."
::= { ocm10gfHist 1 }
ocm10gfHistEntry OBJECT-TYPE
SYNTAX Ocm10gfHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm10gfHMode }
::= { ocm10gfHistTable 1 }
Ocm10gfHistEntry ::=
SEQUENCE
{
ocm10gfHMode HistoryMode,
ocm10gfHNumEvents Counter
}
ocm10gfHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ocm10gfHistEntry 1 }
ocm10gfHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OCM10GF modules."
::= { ocm10gfHistEntry 2 }
ocm10gfHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm10gfHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OCM10GF module"
::= { ocm10gfHist 2 }
ocm10gfHHistEntry OBJECT-TYPE
SYNTAX Ocm10gfHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm10gfHHistMode, ocm10gfHHistLocation, ocm10gfHHistShelf,
ocm10gfHHistSlot }
::= { ocm10gfHHistTable 1 }
Ocm10gfHHistEntry ::=
SEQUENCE
{
ocm10gfHHistMode HistoryMode,
ocm10gfHHistLocation CardLocation,
ocm10gfHHistShelf CardShelf,
ocm10gfHHistSlot INTEGER,
ocm10gfHLastBootTime DateAndTime,
ocm10gfHAvailTime Counter,
ocm10gfHErrFreeSecs Counter
}
ocm10gfHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ocm10gfHHistEntry 1 }
ocm10gfHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { ocm10gfHHistEntry 2 }
ocm10gfHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { ocm10gfHHistEntry 3 }
ocm10gfHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { ocm10gfHHistEntry 4 }
ocm10gfHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { ocm10gfHHistEntry 5 }
ocm10gfHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has been up and
running."
::= { ocm10gfHHistEntry 6 }
ocm10gfHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has not
experienced any alarms."
::= { ocm10gfHHistEntry 7 }
-- The elements in the ocm2Hist subgroup of the historical subgroup
ocm2HistTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm2HistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the OCM2 module."
::= { ocm2Hist 1 }
ocm2HistEntry OBJECT-TYPE
SYNTAX Ocm2HistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm2HMode }
::= { ocm2HistTable 1 }
Ocm2HistEntry ::=
SEQUENCE
{
ocm2HMode HistoryMode,
ocm2HNumEvents Counter
}
ocm2HMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ocm2HistEntry 1 }
ocm2HNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OCM2 modules."
::= { ocm2HistEntry 2 }
ocm2HHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm2HHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OCM2 module"
::= { ocm2Hist 2 }
ocm2HHistEntry OBJECT-TYPE
SYNTAX Ocm2HHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm2HHistMode, ocm2HHistLocation, ocm2HHistShelf,
ocm2HHistSlot }
::= { ocm2HHistTable 1 }
Ocm2HHistEntry ::=
SEQUENCE
{
ocm2HHistMode HistoryMode,
ocm2HHistLocation CardLocation,
ocm2HHistShelf CardShelf,
ocm2HHistSlot INTEGER,
ocm2HLastBootTime DateAndTime,
ocm2HAvailTime Counter,
ocm2HErrFreeSecs Counter
}
ocm2HHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ocm2HHistEntry 1 }
ocm2HHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { ocm2HHistEntry 2 }
ocm2HHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { ocm2HHistEntry 3 }
ocm2HHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { ocm2HHistEntry 4 }
ocm2HLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { ocm2HHistEntry 5 }
ocm2HAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has been up and
running."
::= { ocm2HHistEntry 6 }
ocm2HErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has not
experienced any alarms."
::= { ocm2HHistEntry 7 }
-- The elements in the oscHist subgroup of the historical subgroup
oscHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the OSC module."
::= { oscHist 1 }
oscHistEntry OBJECT-TYPE
SYNTAX OscHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oscHMode }
::= { oscHistTable 1 }
OscHistEntry ::=
SEQUENCE
{
oscHMode HistoryMode,
oscHNumEvents Counter
}
oscHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { oscHistEntry 1 }
oscHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OSC modules."
::= { oscHistEntry 2 }
oscHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF OscHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OSC module"
::= { oscHist 2 }
oscHHistEntry OBJECT-TYPE
SYNTAX OscHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oscHHistMode, oscHHistLocation, oscHHistShelf,
oscHHistSlot }
::= { oscHHistTable 1 }
OscHHistEntry ::=
SEQUENCE
{
oscHHistMode HistoryMode,
oscHHistLocation CardLocation,
oscHHistShelf CardShelf,
oscHHistSlot INTEGER,
oscHLastBootTime DateAndTime,
oscHAvailTime Counter,
oscHErrFreeSecs Counter
}
oscHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { oscHHistEntry 1 }
oscHHistLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { oscHHistEntry 2 }
oscHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { oscHHistEntry 3 }
oscHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { oscHHistEntry 4 }
oscHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { oscHHistEntry 5 }
oscHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has been up and
running."
::= { oscHHistEntry 6 }
oscHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has not
experienced any alarms."
::= { oscHHistEntry 7 }
-- The elements in the ocm4gHist subgroup of the historical subgroup
ocm4gHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm4gHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for historical
data collected for the OCM4G module."
::= { ocm4gHist 1 }
ocm4gHistEntry OBJECT-TYPE
SYNTAX Ocm4gHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm4gHMode }
::= { ocm4gHistTable 1 }
Ocm4gHistEntry ::=
SEQUENCE
{
ocm4gHMode HistoryMode,
ocm4gHNumEvents Counter
}
ocm4gHMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ocm4gHistEntry 1 }
ocm4gHNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OCM4G modules."
::= { ocm4gHistEntry 2 }
ocm4gHHistTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ocm4gHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each OCM4G module"
::= { ocm4gHist 2 }
ocm4gHHistEntry OBJECT-TYPE
SYNTAX Ocm4gHHistEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ocm4gHHistMode, ocm4gHHistLocation, ocm4gHHistShelf,
ocm4gHHistSlot }
::= { ocm4gHHistTable 1 }
Ocm4gHHistEntry ::=
SEQUENCE
{
ocm4gHHistMode HistoryMode,
ocm4gHHistLocation INTEGER,
ocm4gHHistShelf CardShelf,
ocm4gHHistSlot INTEGER,
ocm4gHLastBootTime DateAndTime,
ocm4gHAvailTime Counter,
ocm4gHErrFreeSecs Counter
}
ocm4gHHistMode OBJECT-TYPE
SYNTAX HistoryMode
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The mode of the data collection. Valid values are:
daily or longterm."
::= { ocm4gHHistEntry 1 }
ocm4gHHistLocation OBJECT-TYPE
SYNTAX INTEGER { local(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the module. Choices are local or remote."
::= { ocm4gHHistEntry 2 }
ocm4gHHistShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the module is in."
::= { ocm4gHHistEntry 3 }
ocm4gHHistSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the module is in."
::= { ocm4gHHistEntry 4 }
ocm4gHLastBootTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the last boot for this module."
::= { ocm4gHHistEntry 5 }
ocm4gHAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has been up and
running."
::= { ocm4gHHistEntry 6 }
ocm4gHErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of seconds that this module has not
experienced any alarms."
::= { ocm4gHHistEntry 7 }
-- The elements in the oscHist subgroup of the historical subgroup
-- CPE port 96 interval entries
mcmescPortHIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescPortHIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the mcmesc port counters."
::= { mcmescHist 3 }
mcmescPortHIntervalEntry OBJECT-TYPE
SYNTAX McmescPortHIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescPortHIntervalLocation, mcmescPortHIntervalShelf,
mcmescPortHIntervalSlot, mcmescPortHIntervalPort,
mcmescPortHIntervalNumber }
::= { mcmescPortHIntervalTable 1 }
McmescPortHIntervalEntry ::=
SEQUENCE
{
mcmescPortHIntervalLocation CardLocation,
mcmescPortHIntervalShelf CardShelf,
mcmescPortHIntervalSlot INTEGER,
mcmescPortHIntervalPort INTEGER,
mcmescPortHIntervalNumber INTEGER,
mcmescPortHIntervalDuration DisplayString,
mcmescPortHIntervalEns DisplayString,
mcmescPortHIntervalLoss DisplayString,
mcmescPortHIntervalCrcErr DisplayString,
mcmescPortHIntervalOobErr DisplayString,
mcmescPortHIntervalRdpErr DisplayString
}
mcmescPortHIntervalLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the mcmesc card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
mcmesc cards."
::= { mcmescPortHIntervalEntry 1 }
mcmescPortHIntervalShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 3.
The system automatically determines the right value
for this entry based on the known (available) mcmesc
cards."
::= { mcmescPortHIntervalEntry 2 }
mcmescPortHIntervalSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right value
for this entry based on the known (available)
mcmesc cards."
::= { mcmescPortHIntervalEntry 3 }
mcmescPortHIntervalPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPE port within the shelf the card is in. Valid
values are: 1 to 12. The system automatically
determines the right value for this entry based
on the known (available) mcmesc cards."
::= { mcmescPortHIntervalEntry 4 }
mcmescPortHIntervalNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval number. Valid values are: 1 to 96, where 1
indicates the most recently completed interval."
::= { mcmescPortHIntervalEntry 5 }
mcmescPortHIntervalDuration OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's duration, in seconds, for specific interval.
The * indicates an incomplete interval resulted from interval setting
change."
::= { mcmescPortHIntervalEntry 6 }
mcmescPortHIntervalEns OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's enabled seconds for specific interval."
::= { mcmescPortHIntervalEntry 7 }
mcmescPortHIntervalLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's loss of signal seconds for specific interval."
::= { mcmescPortHIntervalEntry 8 }
mcmescPortHIntervalCrcErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's CRC errs counter for specific interval."
::= { mcmescPortHIntervalEntry 9 }
mcmescPortHIntervalOobErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's Out-of_band error counter for specific
interval."
::= { mcmescPortHIntervalEntry 10 }
mcmescPortHIntervalRdpErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's Running Disparity error counter for
specific interval."
::= { mcmescPortHIntervalEntry 11 }
-- Link port 96 interval entries
mcmescLinkHIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescLinkHIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the mcmesc port counters."
::= { mcmescHist 4 }
mcmescLinkHIntervalEntry OBJECT-TYPE
SYNTAX McmescLinkHIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescLinkHIntervalLocation, mcmescLinkHIntervalShelf,
mcmescLinkHIntervalSlot, mcmescLinkHIntervalNumber }
::= { mcmescLinkHIntervalTable 1 }
McmescLinkHIntervalEntry ::=
SEQUENCE
{
mcmescLinkHIntervalLocation CardLocation,
mcmescLinkHIntervalShelf CardShelf,
mcmescLinkHIntervalSlot INTEGER,
mcmescLinkHIntervalNumber INTEGER,
mcmescLinkHIntervalDuration DisplayString,
mcmescLinkHIntervalTsos DisplayString,
mcmescLinkHIntervalLoss DisplayString,
mcmescLinkHIntervalCrcErr DisplayString,
mcmescLinkHIntervalOobErr DisplayString,
mcmescLinkHIntervalRdpErr DisplayString
}
mcmescLinkHIntervalLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the mcmesc card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
mcmesc cards."
::= { mcmescLinkHIntervalEntry 1 }
mcmescLinkHIntervalShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 2.
The system automatically determines the right value
for this entry based on the known (available) mcmesc
cards."
::= { mcmescLinkHIntervalEntry 2 }
mcmescLinkHIntervalSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right value
for this entry based on the known (available)
mcmesc cards."
::= { mcmescLinkHIntervalEntry 3 }
mcmescLinkHIntervalNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interval number. Valid values are: 1 to 96, where
1 indicates the most recently completed interval."
::= { mcmescLinkHIntervalEntry 4 }
mcmescLinkHIntervalDuration OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's duration, in seconds, for specific interval.
The * indicates an incomplete interval resulted from interval setting
change."
::= { mcmescLinkHIntervalEntry 5 }
mcmescLinkHIntervalTsos OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's test-sequence on seconds for specific interval."
::= { mcmescLinkHIntervalEntry 6 }
mcmescLinkHIntervalLoss OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's loss of signal seconds for specific interval."
::= { mcmescLinkHIntervalEntry 7 }
mcmescLinkHIntervalCrcErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's CRC errs counter for specific interval."
::= { mcmescLinkHIntervalEntry 8 }
mcmescLinkHIntervalOobErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's Out-of_band error counter for specific
interval."
::= { mcmescLinkHIntervalEntry 9 }
mcmescLinkHIntervalRdpErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's Running Disparity error counter for
specific interval."
::= { mcmescLinkHIntervalEntry 10 }
-- CPE port's total perf counter of up to 96 intervals
mcmescPortHTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescPortHTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
mcmesc cpe port's total counters of up to 96 intervals."
::= { mcmescHist 5 }
mcmescPortHTotalEntry OBJECT-TYPE
SYNTAX McmescPortHTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescPortHTotalCardLocation, mcmescPortHTotalCardShelf,
mcmescPortHTotalCardSlot, mcmescPortHTotalPort }
::= { mcmescPortHTotalTable 1 }
McmescPortHTotalEntry ::=
SEQUENCE
{
mcmescPortHTotalCardLocation CardLocation,
mcmescPortHTotalCardShelf CardShelf,
mcmescPortHTotalCardSlot INTEGER,
mcmescPortHTotalPort INTEGER,
mcmescPortHTotalDuration Counter,
mcmescPortHTotalEns Counter,
mcmescPortHTotalLoss Counter,
mcmescPortHTotalCrcErr DisplayString,
mcmescPortHTotalOobErr DisplayString,
mcmescPortHTotalRdpErr DisplayString
}
mcmescPortHTotalCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the MCMESC CPE port. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { mcmescPortHTotalEntry 1 }
mcmescPortHTotalCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1..2."
::= { mcmescPortHTotalEntry 2 }
mcmescPortHTotalCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the Module is in."
::= { mcmescPortHTotalEntry 3 }
mcmescPortHTotalPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPE port's index."
::= { mcmescPortHTotalEntry 4 }
mcmescPortHTotalDuration OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's total duration of up to 96 intervals."
::= { mcmescPortHTotalEntry 5 }
mcmescPortHTotalEns OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's total enabled seconds during up to 96
intervals."
::= { mcmescPortHTotalEntry 6 }
mcmescPortHTotalLoss OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's total loss of signal seconds during
up to 96 intervals."
::= { mcmescPortHTotalEntry 7 }
mcmescPortHTotalCrcErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's total CRC error counter during up to
96 intervals."
::= { mcmescPortHTotalEntry 8 }
mcmescPortHTotalOobErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's total Out-Of_Band error counter during
up to 96 intervals."
::= { mcmescPortHTotalEntry 9 }
mcmescPortHTotalRdpErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC CPE port's total Running Disparity error counter
during up to 96 intervals."
::= { mcmescPortHTotalEntry 10 }
-- Link port's total perf counter of up to 96 intervals
mcmescLinkHTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescLinkHTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
mcmesc cpe port's total counters of up to 96 intervals."
::= { mcmescHist 6 }
mcmescLinkHTotalEntry OBJECT-TYPE
SYNTAX McmescLinkHTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescLinkHTotalCardLocation, mcmescLinkHTotalCardShelf,
mcmescLinkHTotalCardSlot }
::= { mcmescLinkHTotalTable 1 }
McmescLinkHTotalEntry ::=
SEQUENCE
{
mcmescLinkHTotalCardLocation CardLocation,
mcmescLinkHTotalCardShelf CardShelf,
mcmescLinkHTotalCardSlot INTEGER,
mcmescLinkHTotalDuration Counter,
mcmescLinkHTotalTsos Counter,
mcmescLinkHTotalLoss Counter,
mcmescLinkHTotalCrcErr DisplayString,
mcmescLinkHTotalOobErr DisplayString,
mcmescLinkHTotalRdpErr DisplayString,
mcmescLinkHTotalBer DisplayString
}
mcmescLinkHTotalCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Location of the MCMESC link port. Valid values are: Local in
the same chassis, or remote to this chassis"
::= { mcmescLinkHTotalEntry 1 }
mcmescLinkHTotalCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1..2."
::= { mcmescLinkHTotalEntry 2 }
mcmescLinkHTotalCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the shelf the Module is in."
::= { mcmescLinkHTotalEntry 3 }
mcmescLinkHTotalDuration OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's total duration of up to 96 intervals."
::= { mcmescLinkHTotalEntry 4 }
mcmescLinkHTotalTsos OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's total test-sequence on seconds during up to 96
intervals."
::= { mcmescLinkHTotalEntry 5 }
mcmescLinkHTotalLoss OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's total loss of signal seconds during
up to 96 intervals."
::= { mcmescLinkHTotalEntry 6 }
mcmescLinkHTotalCrcErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's total CRC error counter during up to
96 intervals."
::= { mcmescLinkHTotalEntry 7 }
mcmescLinkHTotalOobErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's total Out-Of_Band error counter during
up to 96 intervals."
::= { mcmescLinkHTotalEntry 8 }
mcmescLinkHTotalRdpErr OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"MCMESC link port's total Running Disparity error counter
during up to 96 intervals."
::= { mcmescLinkHTotalEntry 9 }
-- The elements in the systemCond subgroup of the specialConditions
sysCStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The global status of the system as computed based on
the traps (events) that are generated. Choices are:
Critical, Major, Minor or Normal."
::= { systemCond 1 }
sysCSetMode OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If on, the special conditions counters will be
activated. These counters continue counting until
the mode is off. On startup, this flag is off."
::= { systemCond 2 }
sysCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds since this mode is started
that the system has been up and running. The Criteria
for the system available time is having at least one CP
running with atmost non-service affecting minor
alarm system status"
::= { systemCond 3 }
sysCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds since this mode is started
that the device has not experienced any alarms. This
counter is across all cards in the chassis. The
system must be in Normal status for this counter to
be incremented."
::= { systemCond 4 }
-- The elements in the downloadCond subgroup of the specialConditions
dlCStatus OBJECT-TYPE
SYNTAX DownloadStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The global status of the download task. The download task
(download to the device) is either ftp-inprogress, module
update inprogress or currently idle. Since only one download
at the time is handled by the system, this flag is set to
inprogress as soon as any download starts.
It is reset back to idle when the download is completed.
This flag is set to idle on system startup. This flag
can be remotely set to idle if a previous FTP download
was interrupted."
::= { downloadCond 1 }
dlCOkDownloads OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of successful downloads in this time
interval (15 minutes)."
::= { downloadCond 2 }
dlCBadDownloads OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of failed downloads in this time
interval (15 minutes)."
::= { downloadCond 3 }
dlCLongestTime OBJECT-TYPE
SYNTAX Gauge
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Longest time for any download, in seconds, in this
time interval (15 minutes)."
::= { downloadCond 4 }
dlCLongestSize OBJECT-TYPE
SYNTAX Gauge
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Longest download size for any download, in bytes, in
this time interval (15 minutes)."
::= { downloadCond 5 }
dlCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns software counters On or Off."
::= { downloadCond 6 }
-- The elements in the cpCond subgroup of the specialConditions
cpCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of events received by the active CP
since this mode was activated."
::= { cpCond 1 }
cpCTrapsSent OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of traps sent by the active CP since
this mode was activated."
::= { cpCond 2 }
cpCSNMPCmdsRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of SNMP commands received by the active
CP since this mode was activated."
::= { cpCond 3 }
cpCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns software counters On or Off."
::= { cpCond 4 }
cpCCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpCCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters. It is only
applicable to the active MPM card."
::= { cpCond 5 }
cpCCntrEntry OBJECT-TYPE
SYNTAX CpCCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpCCntrShelf, cpCCntrSlot, cpCCntrType }
::= { cpCCntrTable 1 }
CpCCntrEntry ::=
SEQUENCE
{
cpCCntrShelf CardShelf,
cpCCntrSlot INTEGER,
cpCCntrType INTEGER,
cpCTotPktSent Counter,
cpCTotPktRcvd Counter,
cpCBadPktRcvd Counter,
cpCTotBadTrans Counter,
cpCBytesSent Counter,
cpCBytesRcvd Counter,
cpCMsgsDlvrd Counter,
cpCBufAllocFail Counter,
cpCEcbAllocFail Counter
}
cpCCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10.
The system automatically determines the right value
for this entry based on the value of the current
active CP card."
::= { cpCCntrEntry 1 }
cpCCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right value
for this entry based on the value of the current
active CP card."
::= { cpCCntrEntry 2 }
cpCCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { cpCCntrEntry 3 }
cpCTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { cpCCntrEntry 4 }
cpCTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { cpCCntrEntry 5 }
cpCBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { cpCCntrEntry 6 }
cpCTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { cpCCntrEntry 7 }
cpCBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { cpCCntrEntry 8 }
cpCBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { cpCCntrEntry 9 }
cpCMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { cpCCntrEntry 10 }
cpCBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { cpCCntrEntry 11 }
cpCEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { cpCCntrEntry 12 }
cpCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each communication processor"
::= { cpCond 6 }
cpCPerfEntry OBJECT-TYPE
SYNTAX CpCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { cpCPerfShelf, cpCPerfSlot }
::= { cpCPerfTable 1 }
CpCPerfEntry ::=
SEQUENCE
{
cpCPerfShelf CardShelf,
cpCPerfSlot INTEGER,
cpCPerfMode RedundancyMode,
cpCPerfState CardState,
cpCPerfStatus CardStatus,
cpCAvailTime Counter,
cpCErrFreeSecs Counter
}
cpCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { cpCPerfEntry 1 }
cpCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { cpCPerfEntry 2 }
cpCPerfMode OBJECT-TYPE
SYNTAX RedundancyMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The valid types are: active CP or standby CP"
::= { cpCPerfEntry 3 }
cpCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the communication card. The states
are: online, offline, empty, loopback or diagnostics."
::= { cpCPerfEntry 4 }
cpCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the communication processor. This
status represents the state of the communication
processor and in general is different from the
status of the system."
::= { cpCPerfEntry 5 }
cpCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds since this mode is started
that this CP has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { cpCPerfEntry 7 }
cpCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds since this mode is started
that this CP has not experienced any alarms."
::= { cpCPerfEntry 8 }
-- The elements in the ccCond subgroup of the specialConditions
ccCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of events received for all CC's since
this mode was started."
::= { ccCond 1 }
ccCCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcCCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { ccCond 2 }
ccCCntrEntry OBJECT-TYPE
SYNTAX CcCCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccCCntrLocation, ccCCntrShelf, ccCCntrSlot,
ccCCntrType }
::= { ccCCntrTable 1 }
CcCCntrEntry ::=
SEQUENCE
{
ccCCntrLocation CardLocation,
ccCCntrShelf CardShelf,
ccCCntrSlot INTEGER,
ccCCntrType INTEGER,
ccCCounterFlag FlagType,
ccCTotPktSent Counter,
ccCTotPktRcvd Counter,
ccCBadPktRcvd Counter,
ccCTotBadTrans Counter,
ccCBytesSent Counter,
ccCBytesRcvd Counter,
ccCMsgsDlvrd Counter,
ccCBufAllocFail Counter,
ccCEcbAllocFail Counter,
ccCClearCntrs ResetType
}
ccCCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the CC card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
CC cards."
::= { ccCCntrEntry 1 }
ccCCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10.
The system automatically determines the right value
for this entry based on the known (available) CC
cards."
::= { ccCCntrEntry 2 }
ccCCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right value
for this entry based on the known (available)
CC cards."
::= { ccCCntrEntry 3 }
ccCCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), iwm(2) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { ccCCntrEntry 4 }
ccCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns software counters, both On or both Off for this CC. When Off Clears both counters Statistic information "
::= { ccCCntrEntry 5 }
ccCTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { ccCCntrEntry 6 }
ccCTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { ccCCntrEntry 7 }
ccCBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { ccCCntrEntry 8 }
ccCTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { ccCCntrEntry 9 }
ccCBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { ccCCntrEntry 10 }
ccCBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { ccCCntrEntry 11 }
ccCMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { ccCCntrEntry 12 }
ccCBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { ccCCntrEntry 13 }
ccCEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { ccCCntrEntry 14 }
ccCClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other."
::= { ccCCntrEntry 15 }
ccCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF CcCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each channel card."
::= { ccCond 3 }
ccCPerfEntry OBJECT-TYPE
SYNTAX CcCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { ccCPerfLocation, ccCPerfShelf, ccCPerfSlot }
::= { ccCPerfTable 1 }
CcCPerfEntry ::=
SEQUENCE
{
ccCPerfLocation CardLocation,
ccCPerfShelf CardShelf,
ccCPerfSlot INTEGER,
ccCPerfState CardState,
ccCPerfStatus CardStatus,
ccCAvailTime Counter,
ccCErrFreeSecs Counter,
ccCBiasCurrent INTEGER,
ccCModulation INTEGER,
ccCApc INTEGER,
ccCIwmModulation INTEGER,
ccCLaserOnOff FlagType,
ccCTemperature Gauge,
ccCIntensity Gauge,
ccCSignalStrength Gauge,
ccCLossOfLight Boolean,
ccCSignalDetect Boolean,
ccCRefClock INTEGER,
ccCClockDiv INTEGER,
ccCProtectionMode INTEGER
}
ccCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Valid choices are Local
or Remote. The system automatically selects this
value based on the known (available) CC cards."
::= { ccCPerfEntry 1 }
ccCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { ccCPerfEntry 2 }
ccCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { ccCPerfEntry 3 }
ccCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the channel card. The states'
are: online, offline, empty, loopback or diagnostics."
::= { ccCPerfEntry 4 }
ccCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the channel card. This
status represents the status of the communication
processor and in general is different from the
status of the system."
::= { ccCPerfEntry 5 }
ccCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this CC has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { ccCPerfEntry 6 }
ccCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this CC has not experienced any alarms."
::= { ccCPerfEntry 7 }
ccCBiasCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bias current for the optical laser."
::= { ccCPerfEntry 8 }
ccCModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The frequency modulation for the optical laser."
::= { ccCPerfEntry 9 }
ccCApc OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The APC value."
::= { ccCPerfEntry 10 }
ccCIwmModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The frequency modulation for the IWM channel."
::= { ccCPerfEntry 11 }
ccCLaserOnOff OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The laser On/Off flag."
::= { ccCPerfEntry 12 }
ccCTemperature OBJECT-TYPE
SYNTAX Gauge
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current temperature, or the operating temperature
of the optical device."
::= { ccCPerfEntry 13 }
ccCIntensity OBJECT-TYPE
SYNTAX Gauge
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The intensity of the optical light."
::= { ccCPerfEntry 14 }
ccCSignalStrength OBJECT-TYPE
SYNTAX Gauge
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current signal strength for the optical path."
::= { ccCPerfEntry 15 }
ccCLossOfLight OBJECT-TYPE
SYNTAX Boolean
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If set to true, no laser light is present. If set to
false, no loss of light has occurred."
::= { ccCPerfEntry 16 }
ccCSignalDetect OBJECT-TYPE
SYNTAX Boolean
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If set to true, signal is detected. If set to false,
no signal is present."
::= { ccCPerfEntry 17 }
ccCRefClock OBJECT-TYPE
SYNTAX INTEGER { en1660 (1),
en1944(2),
en1953(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The value of the reference clock in decimal notation.
For a given value, like 1660, the actual value is
16.60-EN. In otherwords, assume a two digit decimal
point, plus any appropriate scaling factor."
::= { ccCPerfEntry 18 }
ccCClockDiv OBJECT-TYPE
SYNTAX INTEGER { dout-1250(1), dout-622(2), dout-155(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The clock divisor. Values are 1250, 622 or 155 in the
appropriate clock frequency scale."
::= { ccCPerfEntry 19 }
ccCProtectionMode OBJECT-TYPE
SYNTAX INTEGER
{
active(1),
standby(2),
na(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"UPSR Protection Mode: active, standby and na."
::= { ccCPerfEntry 20 }
-- The elements in the muxCond subgroup of the specialConditions
muxCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
MUX's since this mode is started."
::= { muxCond 1 }
muxCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF MuxCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each mux/demux card"
::= { muxCond 2 }
muxCPerfEntry OBJECT-TYPE
SYNTAX MuxCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { muxCPerfLocation, muxCPerfShelf, muxCPerfSlot }
::= { muxCPerfTable 1 }
MuxCPerfEntry ::=
SEQUENCE
{
muxCPerfLocation CardLocation,
muxCPerfShelf CardShelf,
muxCPerfSlot INTEGER,
muxCType INTEGER,
muxCPerfState CardState,
muxCPerfStatus CardStatus,
muxCAvailTime Counter,
muxCErrFreeSecs Counter
}
muxCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { muxCPerfEntry 1 }
muxCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { muxCPerfEntry 2 }
muxCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { muxCPerfEntry 3 }
muxCType OBJECT-TYPE
SYNTAX INTEGER { mux(4), demux(5), w4cd(10), w2cmd(13), w4cm(21)}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The type of the mux. The choices are: mux or demux."
::= { muxCPerfEntry 4 }
muxCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the mux card. The states are:
online, offline, empty, loopback or diag."
::= { muxCPerfEntry 5 }
muxCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the mux card. This status represents
the status of the mux card and in general is
different from the status of the system."
::= { muxCPerfEntry 6 }
muxCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this Mux has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { muxCPerfEntry 7 }
muxCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this mux has not experienced any alarms."
::= { muxCPerfEntry 8 }
muxCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns special condition software counters On or Off
for this card. Default is off."
::= { muxCond 3}
-- The elements in the psCond subgroup of the specialConditions
psCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
Power Supplies since this mode is started."
::= { psCond 1 }
psCVoltageLevel3pt3Volt OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Voltage Level of the 3.3 V power supply. Need to divide
this value by ten to get the actual voltage level."
::= { psCond 2 }
psCVoltageLevel5Volt OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Voltage Level of the 5 V power supply. Need to divide
this value by ten to get the actual voltage level."
::= { psCond 3 }
psCVoltageLevel12Volt OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Voltage Level of the 12 V power supply. Need to divide
this value by ten to get the actual voltage level."
::= { psCond 4 }
psCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PsCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each power supply card"
::= { psCond 5 }
psCPerfEntry OBJECT-TYPE
SYNTAX PsCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { psCPerfID }
::= { psCPerfTable 1 }
PsCPerfEntry ::=
SEQUENCE
{
psCPerfID INTEGER,
psCPerfType RedundancyMode,
psCPerfState CardState,
psCPerfStatus CardStatus
}
psCPerfID OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The module id where ps is in. Valid values are: 1 to 4"
::= { psCPerfEntry 1 }
psCPerfType OBJECT-TYPE
SYNTAX RedundancyMode
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The type of the power supply card. The choices are:
active (primary PS) or standby."
::= { psCPerfEntry 2 }
psCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the power supply card. The states are:
online, offline, empty, loopback or diagnostics."
::= { psCPerfEntry 3 }
psCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the power supply card. This status
represents the status of the ps card and in general is
different from the status of the system."
::= { psCPerfEntry 4 }
-- The elements in the fadmCond subgroup of the specialConditions
fadmCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
FADM's since this mode is started."
::= { fadmCond 1 }
fadmCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns software counters On or Off for this FADM."
::= { fadmCond 2 }
fadmCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FadmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each fadm card"
::= { fadmCond 3 }
fadmCPerfEntry OBJECT-TYPE
SYNTAX FadmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fadmCPerfLocation, fadmCPerfShelf, fadmCPerfSlot }
::= { fadmCPerfTable 1 }
FadmCPerfEntry ::=
SEQUENCE
{
fadmCPerfLocation CardLocation,
fadmCPerfShelf CardShelf,
fadmCPerfSlot INTEGER,
fadmCPerfState CardState,
fadmCPerfStatus CardStatus,
fadmCAvailTime Counter,
fadmCErrFreeSecs Counter
}
fadmCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { fadmCPerfEntry 1 }
fadmCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { fadmCPerfEntry 2 }
fadmCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { fadmCPerfEntry 3 }
fadmCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the mux card. The states are:
online, offline, empty, loopback or diag."
::= { fadmCPerfEntry 5 }
fadmCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the mux card. This status represents
the status of the mux card and in general is
different from the status of the system."
::= { fadmCPerfEntry 6 }
fadmCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this Mux has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { fadmCPerfEntry 7 }
fadmCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this mux has not experienced any alarms."
::= { fadmCPerfEntry 8 }
-- The elements in the oppmCond subgroup of the specialConditions
oppmCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
OPPMs' since this mode is started."
::= { oppmCond 1 }
oppmCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OppmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each oppm card"
::= { oppmCond 2 }
oppmCPerfEntry OBJECT-TYPE
SYNTAX OppmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { oppmCPerfLocation, oppmCPerfShelf, oppmCPerfSlot }
::= { oppmCPerfTable 1 }
OppmCPerfEntry ::=
SEQUENCE
{
oppmCPerfLocation CardLocation,
oppmCPerfShelf CardShelf,
oppmCPerfSlot INTEGER,
oppmCPerfState CardState,
oppmCPerfStatus CardStatus,
oppmCAvailTime Counter,
oppmCErrFreeSecs Counter
}
oppmCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { oppmCPerfEntry 1 }
oppmCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { oppmCPerfEntry 2 }
oppmCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { oppmCPerfEntry 3 }
oppmCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the oppm card. The states are:
online, offline, empty, loopback or diag."
::= { oppmCPerfEntry 4 }
oppmCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the oppm card. This status represents
the status of the oppm card and in general is
different from the status of the system."
::= { oppmCPerfEntry 5 }
oppmCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this oppm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { oppmCPerfEntry 6 }
oppmCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this oppm has not experienced any alarms."
::= { oppmCPerfEntry 7 }
oppmCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns special condition software counters On or Off for
this card. Default is off."
::= { oppmCond 3}
-- The elements in the mcmCond subgroup of the specialConditions
mcmCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of events received for all MCM's since
this mode was started."
::= { mcmCond 1 }
mcmCCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmCCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entry for the software counters."
::= { mcmCond 2 }
mcmCCntrEntry OBJECT-TYPE
SYNTAX McmCCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmCCntrLocation, mcmCCntrShelf, mcmCCntrSlot,
mcmCCntrType }
::= { mcmCCntrTable 1 }
McmCCntrEntry ::=
SEQUENCE
{
mcmCCntrLocation CardLocation,
mcmCCntrShelf CardShelf,
mcmCCntrSlot INTEGER,
mcmCCntrType INTEGER,
mcmCCounterFlag FlagType,
mcmCTotPktSent Counter,
mcmCTotPktRcvd Counter,
mcmCBadPktRcvd Counter,
mcmCTotBadTrans Counter,
mcmCBytesSent Counter,
mcmCBytesRcvd Counter,
mcmCMsgsDlvrd Counter,
mcmCBufAllocFail Counter,
mcmCEcbAllocFail Counter,
mcmCClearCntrs ResetType
}
mcmCCntrLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the MCM card. The values are: Local
or Remote. The system automatically determines the
right value for this entry based on the known
MCM cards."
::= { mcmCCntrEntry 1 }
mcmCCntrShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10.
The system automatically determines the right value
for this entry based on the known (available) MCM
cards."
::= { mcmCCntrEntry 2 }
mcmCCntrSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in. The
system automatically determines the right value
for this entry based on the known (available)
MCM cards."
::= { mcmCCntrEntry 3 }
mcmCCntrType OBJECT-TYPE
SYNTAX INTEGER { spi(1), iwm(2) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The type of the software counter data in this row.
The data is collected for the SPI data channels."
::= { mcmCCntrEntry 4 }
mcmCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns software counters On or Off for this MCM."
::= { mcmCCntrEntry 5 }
mcmCTotPktSent OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of data packets sent over the given data
channel."
::= { mcmCCntrEntry 6 }
mcmCTotPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of data packets received over the given
data channel."
::= { mcmCCntrEntry 7 }
mcmCBadPktRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of bad data packets received over the given
data channel."
::= { mcmCCntrEntry 8 }
mcmCTotBadTrans OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of bad data transmissions over the given
data channel."
::= { mcmCCntrEntry 9 }
mcmCBytesSent OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of bytes sent over the given
data channel."
::= { mcmCCntrEntry 10 }
mcmCBytesRcvd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of data bytes received over the given
data channel."
::= { mcmCCntrEntry 11 }
mcmCMsgsDlvrd OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of complete messages delivered over the
given data channel."
::= { mcmCCntrEntry 12 }
mcmCBufAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of buffer allocation failures for the given
data channel."
::= { mcmCCntrEntry 13 }
mcmCEcbAllocFail OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of Event Control Block allocation failures
for the given data channel."
::= { mcmCCntrEntry 14 }
mcmCClearCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If the value is reset, all software counters for this
15 minute interval are reset to zero. A get on this
will always return other."
::= { mcmCCntrEntry 15 }
mcmCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each channel card"
::= { mcmCond 3 }
mcmCPerfEntry OBJECT-TYPE
SYNTAX McmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmCPerfLocation, mcmCPerfShelf, mcmCPerfSlot }
::= { mcmCPerfTable 1 }
McmCPerfEntry ::=
SEQUENCE
{
mcmCPerfLocation CardLocation,
mcmCPerfShelf CardShelf,
mcmCPerfSlot INTEGER,
mcmCPerfState CardState,
mcmCPerfStatus CardStatus,
mcmCAvailTime Counter,
mcmCErrFreeSecs Counter,
mcmCBiasCurrent INTEGER,
mcmCModulation INTEGER,
mcmCApc INTEGER,
mcmCIwmModulation INTEGER,
mcmCLaserOnOff FlagType,
mcmCTemperature Gauge,
mcmCIntensity Gauge,
mcmCSignalStrength Gauge,
mcmCLossOfLight Boolean,
mcmCSignalDetect Boolean,
mcmCRefClock INTEGER,
mcmCClockDiv INTEGER
}
mcmCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Valid choices are Local
or Remote. The system automatically selects this
value based on the known (available) CC cards."
::= { mcmCPerfEntry 1 }
mcmCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { mcmCPerfEntry 2 }
mcmCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { mcmCPerfEntry 3 }
mcmCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the channel card. The states'
are: online, offline, empty, loopback or diagnostics."
::= { mcmCPerfEntry 4 }
mcmCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the channel card. This
status represents the status of the communication
processor and in general is different from the
status of the system."
::= { mcmCPerfEntry 5 }
mcmCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this CC has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { mcmCPerfEntry 6 }
mcmCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this MCM has not experienced any alarms."
::= { mcmCPerfEntry 7 }
mcmCBiasCurrent OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bias current for the optical laser."
::= { mcmCPerfEntry 8 }
mcmCModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The frequency modulation for the optical laser."
::= { mcmCPerfEntry 9 }
mcmCApc OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The APC value."
::= { mcmCPerfEntry 10 }
mcmCIwmModulation OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The frequency modulation for the IWM channel."
::= { mcmCPerfEntry 11 }
mcmCLaserOnOff OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The laser On/Off flag."
::= { mcmCPerfEntry 12 }
mcmCTemperature OBJECT-TYPE
SYNTAX Gauge
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current temperature, or the operating temperature
of the optical device."
::= { mcmCPerfEntry 13 }
mcmCIntensity OBJECT-TYPE
SYNTAX Gauge
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The intensity of the optical light."
::= { mcmCPerfEntry 14 }
mcmCSignalStrength OBJECT-TYPE
SYNTAX Gauge
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current signal strength for the optical path."
::= { mcmCPerfEntry 15 }
mcmCLossOfLight OBJECT-TYPE
SYNTAX Boolean
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If set to true, no laser light is present. If set to
false, no loss of light has occurred."
::= { mcmCPerfEntry 16 }
mcmCSignalDetect OBJECT-TYPE
SYNTAX Boolean
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If set to true, signal is detected. If set to false,
no signal is present."
::= { mcmCPerfEntry 17 }
mcmCRefClock OBJECT-TYPE
SYNTAX INTEGER
{
en1660 (1),
en1944(2),
en1953(3)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The value of the reference clock in decimal notation.
For a given value, like 1660, the actual value is
16.60-EN. In otherwords, assume a two digit decimal
point, plus any appropriate scaling factor."
::= { mcmCPerfEntry 18 }
mcmCClockDiv OBJECT-TYPE
SYNTAX INTEGER { dout-1250(1), dout-622(2), dout-155(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The clock divisor. Values are 1250, 622 or 155 in the
appropriate clock frequency scale."
::= { mcmCPerfEntry 19 }
mcmPortCCntrTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmPortCCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
MCM port's current counters."
::= { mcmCond 4 }
mcmPortCCntrEntry OBJECT-TYPE
SYNTAX McmPortCCntrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmPortCCntrCardLocation, mcmPortCCntrCardShelf,
mcmPortCCntrCardSlot, mcmPortCCntrIndex }
::= { mcmPortCCntrTable 1 }
McmPortCCntrEntry ::=
SEQUENCE
{
mcmPortCCntrCardLocation CardLocation,
mcmPortCCntrCardShelf CardShelf,
mcmPortCCntrCardSlot INTEGER,
mcmPortCCntrIndex INTEGER,
mcmPortCCntrASs Counter,
-- mcmPortCCntrFrameASs Counter,
mcmPortCCntrFEs Counter,
mcmPortCCntrCRCErrs Counter,
mcmPortCCntrSESs Counter,
mcmPortCCntrSEFSs Counter,
mcmPortCCntrUASs Counter,
mcmPortCCntrLESs Counter,
mcmPortCCntrBESs Counter,
mcmPortCCntrDMs Counter,
mcmPortCCntrLCVs Counter
}
mcmPortCCntrCardLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Location of the MCM port. Valid values are:
Local in the same chassis, or remote to this
chassis"
::= { mcmPortCCntrEntry 1 }
mcmPortCCntrCardShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values
are: 2..3."
::= { mcmPortCCntrEntry 2 }
mcmPortCCntrCardSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the Module is in."
::= { mcmPortCCntrEntry 3 }
mcmPortCCntrIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Port's index."
::= { mcmPortCCntrEntry 4 }
mcmPortCCntrASs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"mcm port's ASs counter less than 15 mins."
::= { mcmPortCCntrEntry 5 }
--mcmPortCCntrFrameASs OBJECT-TYPE
-- SYNTAX Counter
-- ACCESS not-accessible
-- STATUS mandatory
-- DESCRIPTION
-- "MCM port's FrameASs counter less than 15 mins."
-- ::= { mcmPortCCntrEntry 6 }
mcmPortCCntrFEs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCM port's FEs counter less than 15 mins."
::= { mcmPortCCntrEntry 7 }
mcmPortCCntrCRCErrs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCM port's CRC errs counter less than 15 mins."
::= { mcmPortCCntrEntry 8 }
mcmPortCCntrSESs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"mcm port's SESs counter less than 15 mins."
::= { mcmPortCCntrEntry 9 }
mcmPortCCntrSEFSs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCM port's SEFSs counter less than 15 mins."
::= { mcmPortCCntrEntry 10 }
mcmPortCCntrUASs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCM port's UASs counter less than 15 mins."
::= { mcmPortCCntrEntry 11 }
mcmPortCCntrLESs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCM port's LESs counter less than 15 mins."
::= { mcmPortCCntrEntry 12 }
mcmPortCCntrBESs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCM port's BESs counter less than 15 mins."
::= { mcmPortCCntrEntry 13 }
mcmPortCCntrDMs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCM port's DMSs counter less than 15 mins."
::= { mcmPortCCntrEntry 14 }
mcmPortCCntrLCVs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MCM port's LCVs counter less than 15 mins."
::= { mcmPortCCntrEntry 15 }
-- The elements in the fnCond subgroup of the specialConditions subgroup
fnCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
Fans since this mode is started."
::= { fnCond 1 }
fnCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF FnCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each fan module."
::= { fnCond 2 }
fnCPerfEntry OBJECT-TYPE
SYNTAX FnCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { fnCPerfID }
::= { fnCPerfTable 1 }
FnCPerfEntry ::=
SEQUENCE
{
fnCPerfID INTEGER,
fnCPerfState INTEGER,
fnCPerfStatus CardStatus
}
fnCPerfID OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The module ID where the fan module is plugged in."
::= { fnCPerfEntry 1 }
fnCPerfState OBJECT-TYPE
SYNTAX INTEGER
{
fnOK(1),
fnDegrade(2),
fnFailed(3),
fnEmpty(4)
}
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the fan module."
::= { fnCPerfEntry 2 }
fnCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the fan module. This status
represents the status of the fan module and in general is
different from the status of the system."
::= { fnCPerfEntry 3 }
-- The elements in the rpsmCond subgroup of the specialConditions
rpsmCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RPSMs' since this mode is started."
::= { rpsmCond 1 }
rpsmCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RpsmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rpsm card"
::= { rpsmCond 2 }
rpsmCPerfEntry OBJECT-TYPE
SYNTAX RpsmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rpsmCPerfLocation, rpsmCPerfShelf, rpsmCPerfSlot }
::= { rpsmCPerfTable 1 }
RpsmCPerfEntry ::=
SEQUENCE
{
rpsmCPerfLocation CardLocation,
rpsmCPerfShelf CardShelf,
rpsmCPerfSlot INTEGER,
rpsmCPerfState CardState,
rpsmCPerfStatus CardStatus,
rpsmCAvailTime Counter,
rpsmCErrFreeSecs Counter
}
rpsmCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { rpsmCPerfEntry 1 }
rpsmCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { rpsmCPerfEntry 2 }
rpsmCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rpsmCPerfEntry 3 }
rpsmCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the rpsm card. The states are:
online, offline, empty, loopback or diag."
::= { rpsmCPerfEntry 4 }
rpsmCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the rpsm card. This status represents
the status of the rpsm card and in general is
different from the status of the system."
::= { rpsmCPerfEntry 5 }
rpsmCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rpsm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { rpsmCPerfEntry 6 }
rpsmCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rpsm has not experienced any alarms."
::= { rpsmCPerfEntry 7 }
rpsmCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns special condition software counters On or
Off for this card. Default is off."
::= { rpsmCond 3}
-- The elements in the rsdmCond subgroup of the specialConditions
rsdmCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RSDMs' since this mode is started."
::= { rsdmCond 1 }
rsdmCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsdmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each oppm card"
::= { rsdmCond 2 }
rsdmCPerfEntry OBJECT-TYPE
SYNTAX RsdmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsdmCPerfLocation, rsdmCPerfShelf, rsdmCPerfSlot }
::= { rsdmCPerfTable 1 }
RsdmCPerfEntry ::=
SEQUENCE
{
rsdmCPerfLocation CardLocation,
rsdmCPerfShelf CardShelf,
rsdmCPerfSlot INTEGER,
rsdmCPerfState CardState,
rsdmCPerfStatus CardStatus,
rsdmCAvailTime Counter,
rsdmCErrFreeSecs Counter
}
rsdmCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { rsdmCPerfEntry 1 }
rsdmCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { rsdmCPerfEntry 2 }
rsdmCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rsdmCPerfEntry 3 }
rsdmCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the rsdm card. The states are:
online, offline, empty, loopback or diag."
::= { rsdmCPerfEntry 4 }
rsdmCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the rsdm card. This status represents
the status of the rsdm card and in general is
different from the status of the system."
::= { rsdmCPerfEntry 5 }
rsdmCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rsdm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { rsdmCPerfEntry 6 }
rsdmCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rsdm has not experienced any alarms."
::= { rsdmCPerfEntry 7 }
rsdmCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns special condition software counters On
or Off for this card. Default is off."
::= { rsdmCond 3}
-- The elements in the rtdmCond subgroup of the specialConditions
rtdmCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RTDM's since this mode is started."
::= { rtdmCond 1 }
rtdmCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtdmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each mux/demux card"
::= { rtdmCond 2 }
rtdmCPerfEntry OBJECT-TYPE
SYNTAX RtdmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rtdmCPerfLocation, rtdmCPerfShelf, rtdmCPerfSlot }
::= { rtdmCPerfTable 1 }
RtdmCPerfEntry ::=
SEQUENCE
{
rtdmCPerfLocation CardLocation,
rtdmCPerfShelf CardShelf,
rtdmCPerfSlot INTEGER,
rtdmCPerfState CardState,
rtdmCPerfStatus CardStatus,
rtdmCAvailTime Counter,
rtdmCErrFreeSecs Counter
}
rtdmCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card. Choices are local or
remote."
::= { rtdmCPerfEntry 1 }
rtdmCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in. Valid values are: 1 to 10"
::= { rtdmCPerfEntry 2 }
rtdmCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rtdmCPerfEntry 3 }
rtdmCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the mux card. The states are:
online, offline, empty, loopback or diag."
::= { rtdmCPerfEntry 4 }
rtdmCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the mux card. This status represents
the status of the mux card and in general is
different from the status of the system."
::= { rtdmCPerfEntry 5 }
rtdmCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this Mux has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { rtdmCPerfEntry 6 }
rtdmCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this mux has not experienced any alarms."
::= { rtdmCPerfEntry 7 }
rtdmCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns special condition software counters On or Off
for this card. Default is off."
::= { rtdmCond 3}
-- The elements in the osamCond subgroup of the specialConditions
osamCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of events received for all osam's since
this mode was started."
::= { osamCond 1 }
osamCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF OsamCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for
special conditions performance data collected for
each osam module."
::= { osamCond 2 }
osamCPerfEntry OBJECT-TYPE
SYNTAX OsamCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { osamCPerfLocation, osamCPerfShelf, osamCPerfSlot }
::= { osamCPerfTable 1 }
OsamCPerfEntry ::=
SEQUENCE
{
osamCPerfLocation CardLocation,
osamCPerfShelf CardShelf,
osamCPerfSlot INTEGER,
osamCPerfState CardState,
osamCPerfStatus CardStatus,
osamCPerfAvailTime Counter,
osamCPerfErrFreeSecs Counter
}
osamCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Location of the module."
::= { osamCPerfEntry 1 }
osamCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf number in which the module is plugged in."
::= { osamCPerfEntry 2 }
osamCPerfSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot number in which the module is plugged in."
::= { osamCPerfEntry 3 }
osamCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current state of the module."
::= { osamCPerfEntry 4 }
osamCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The current alarm status of the channel."
::= { osamCPerfEntry 5 }
osamCPerfAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds since the start of this mode
that this module has been up and running."
::= { osamCPerfEntry 6 }
osamCPerfErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds since the start of this mode
that this module has been experienced any alarms."
::= { osamCPerfEntry 7 }
osamCPerfCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns osam special condition software counters on
and off. Default is off."
::= { osamCond 3}
-- The elements in the rsmCond subgroup of the specialConditions
rsmCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
RSMs' since this mode is started."
::= { rsmCond 1 }
rsmCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RsmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each rsm card"
::= { rsmCond 2 }
rsmCPerfEntry OBJECT-TYPE
SYNTAX RsmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { rsmCPerfLocation, rsmCPerfShelf, rsmCPerfSlot }
::= { rsmCPerfTable 1 }
RsmCPerfEntry ::=
SEQUENCE
{
rsmCPerfLocation CardLocation,
rsmCPerfShelf CardShelf,
rsmCPerfSlot CardSlot,
rsmCPerfState CardState,
rsmCPerfStatus CardStatus,
rsmCAvailTime Counter,
rsmCErrFreeSecs Counter
}
rsmCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card."
::= { rsmCPerfEntry 1 }
rsmCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { rsmCPerfEntry 2 }
rsmCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { rsmCPerfEntry 3 }
rsmCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the rsm card. The states are:
online, offline, empty, loopback or diag."
::= { rsmCPerfEntry 4 }
rsmCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the rsm card. This status represents
the status of the rsm card and in general is
different from the status of the system."
::= { rsmCPerfEntry 5 }
rsmCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rsm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { rsmCPerfEntry 6 }
rsmCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this rsm has not experienced any alarms."
::= { rsmCPerfEntry 7 }
rsmCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns special condition software counters On
or Off for this card. Default is off."
::= { rsmCond 3}
-- The elements in the upsmCond subgroup of the specialConditions
upsmCNumEvents OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Total number of all traps (events) generated by all
UPSMs' since this mode is started."
::= { upsmCond 1 }
upsmCPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF UpsmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for performance
data collected for each upsm card"
::= { upsmCond 2 }
upsmCPerfEntry OBJECT-TYPE
SYNTAX UpsmCPerfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { upsmCPerfLocation, upsmCPerfShelf, upsmCPerfSlot }
::= { upsmCPerfTable 1 }
UpsmCPerfEntry ::=
SEQUENCE
{
upsmCPerfLocation CardLocation,
upsmCPerfShelf CardShelf,
upsmCPerfSlot CardSlot,
upsmCPerfState CardState,
upsmCPerfStatus CardStatus,
upsmCAvailTime Counter,
upsmCErrFreeSecs Counter
}
upsmCPerfLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The location of the card."
::= { upsmCPerfEntry 1 }
upsmCPerfShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The shelf the card is in."
::= { upsmCPerfEntry 2 }
upsmCPerfSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The slot within the shelf the card is in."
::= { upsmCPerfEntry 3 }
upsmCPerfState OBJECT-TYPE
SYNTAX CardState
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The state of the upsm card. The states are:
online, offline, empty, loopback or diag."
::= { upsmCPerfEntry 4 }
upsmCPerfStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The status of the upsm card. This status represents
the status of the upsm card and in general is
different from the status of the system."
::= { upsmCPerfEntry 5 }
upsmCAvailTime OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this upsm has been up and running. This will
generally be the same as 15 minutes in seconds (900)."
::= { upsmCPerfEntry 6 }
upsmCErrFreeSecs OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The number of seconds in this time slot (15 minutes)
that this upsm has not experienced any alarms."
::= { upsmCPerfEntry 7 }
upsmCCounterFlag OBJECT-TYPE
SYNTAX FlagType
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Turns special condition software counters On
or Off for this card. Default is off."
::= { upsmCond 3}
-- The elements in the eventLog subgroup of the traps
eveTrapThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Threshold before events of the same type are no longer
sent. Default can be a number as small as 1."
::= { eventLog 1 }
eveNumEvents OBJECT-TYPE
SYNTAX EventBuffer
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of events logged in the table below. This
counter is automatically set by the software."
::= { eventLog 2 }
eveLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF EveLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for the
event log buffer. There are a maximum of 700
entries in the event log. The events are kept
in a circular buffer fashion with eveSeqNum
going from 1 to 9999."
::= { eventLog 3 }
eveLogEntry OBJECT-TYPE
SYNTAX EveLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { eveDateTime, eveSeqNum }
::= { eveLogTable 1 }
EveLogEntry ::=
SEQUENCE
{
eveDateTime DateAndTime,
eveEventId INTEGER,
eveSeverity TrapStatus,
eveSysStatus CardStatus,
eveSource DisplayString,
eveDescr DisplayString,
eveTrap Boolean,
eveSeqNum INTEGER
}
eveDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time of the event logged in the buffer"
::= { eveLogEntry 1 }
eveEventId OBJECT-TYPE
SYNTAX INTEGER (0..9999)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The event ID assigned to this event."
::= { eveLogEntry 2 }
eveSeverity OBJECT-TYPE
SYNTAX TrapStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The severity of this event. Could be critical, major,
minor, or normal (informational)."
::= { eveLogEntry 3 }
eveSysStatus OBJECT-TYPE
SYNTAX CardStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current status of the system. Could be critical,
major, minor, or normal (informational)."
::= { eveLogEntry 4 }
eveSource OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..152))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A five to seven tuple string composed of the
following items: System Name:card type (MPM,
OCMITU, OFCM, etc.). location (L for local,
R[number] for remote with optional station number).
shelf #. slot id[. port #][:link name(optional
depending on card type)] [:ring name(optional)] [:path name(optional)].
When an event applies to all slots of the whole
chassis, 0 will be displayed for both shelf and slot.
Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23"
::= { eveLogEntry 5 }
eveDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A string signifying the cause of the error in natural
language (preferrably English) format."
::= { eveLogEntry 6 }
eveTrap OBJECT-TYPE
SYNTAX Boolean
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If set to True, this event was sent as a trap. If
set to False, this event was merely logged and not
sent as a trap."
::= { eveLogEntry 7 }
eveSeqNum OBJECT-TYPE
SYNTAX INTEGER (0..9999)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique sequence number for this event entry in
the event log."
::= { eveLogEntry 8 }
eveDeleteLog OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value is reset, the event log table of the
active cp is deleted - meaning all the log entries
are flushed!!"
::= { eventLog 4 }
eveLastEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and time stamp of the last event log entry. This
provides quick access into the last event log entry."
::= { eventLog 5 }
eveHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 100th event
log entry. This provides quick access into
retrieving the most recent 100 event log entries.
If less than 100 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 6 }
eveTwoHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 200th event
log entry. This provides quick access into
retrieving the most recent 200 event log entries.
If less than 200 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 7 }
eveThreeHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 300th event
log entry. This provides quick access into
retrieving the most recent 300 event log entries.
If less than 300 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 8 }
eveFourHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 400th event
log entry. This provides quick access into
retrieving the most recent 400 event log entries.
If less than 400 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 9 }
eveFiveHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 500th event
log entry. This provides quick access into
retrieving the most recent 500 event log entries.
If less than 500 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 10 }
eveSixHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 600th event
log entry. This provides quick access into
retrieving the most recent 600 event log entries.
If less than 600 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 11 }
eveSevenHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 700th event
log entry. This provides quick access into
retrieving the most recent 700 event log entries.
If less than 700 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 12 }
eveEightHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 800th event
log entry. This provides quick access into
retrieving the most recent 800 event log entries.
If less than 800 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 13 }
eveNineHundredthEntryDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Date and time stamp of the most recent 900th event
log entry. This provides quick access into
retrieving the most recent 900 event log entries.
If less than 900 entries exist in the event log,
the return value contains all zeroes."
::= { eventLog 14 }
-- The elements in the userLog subgroup of the traps
usrNumLogs OBJECT-TYPE
SYNTAX UserBuffer
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of user events logged in the table below. This
counter is automatically set by the software."
::= { userLog 1 }
usrLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF UsrLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for user event
log buffer"
::= { userLog 2 }
usrLogEntry OBJECT-TYPE
SYNTAX UsrLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { usrDateTime, usrLogonId }
::= { usrLogTable 1 }
UsrLogEntry ::=
SEQUENCE
{
usrDateTime DateAndTime,
usrLogonId LogonID,
usrTarget DisplayString (SIZE (0..30)),
usrLogDescr DisplayString (SIZE (0..100)),
usrTrap Boolean
}
usrDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The date and time of the event logged in the buffer"
::= { usrLogEntry 1 }
usrLogonId OBJECT-TYPE
SYNTAX LogonID
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Logon ID of the user causing this event to be
logged."
::= { usrLogEntry 2 }
usrTarget OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A four tuple string composed of the following items:
location (remote or local), type (cp, cc, mux or ps),
shelf, and slot id. The tuples are separated by
comma. Example: local,cp,b,1. This column identifies
which subsystem was affected by the user action."
::= { usrLogEntry 3 }
usrLogDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A string signifying the action logged in natural
language (preferrably English) format."
::= { usrLogEntry 4 }
usrTrap OBJECT-TYPE
SYNTAX Boolean
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"If set to True, this user event was sent as a trap.
If set to False, this event was merely logged and not
sent as a trap."
::= { usrLogEntry 5 }
-- The elements in the alarmLog subgroup of the faults group
alarmNumEvents OBJECT-TYPE
SYNTAX INTEGER(0..300)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of alarms logged in the table below. This
counter is automatically set by the software. The max
is 300 entries."
::= { alarmLog 1}
alarmLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF AlarmLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for the alarm
log buffer"
::= { alarmLog 2 }
alarmLogEntry OBJECT-TYPE
SYNTAX AlarmLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { alarmFirstDateTime, alarmTag }
::= { alarmLogTable 1 }
AlarmLogEntry ::=
SEQUENCE
{
alarmFirstDateTime DateAndTime,
alarmTag INTEGER,
alarmLastDateTime DateAndTime,
alarmEventId INTEGER,
alarmSeverity INTEGER,
alarmSource DisplayString,
alarmDescr DisplayString,
alarmCnt INTEGER,
alarmAck INTEGER,
alarmClear INTEGER
}
alarmFirstDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time for the first alarm occurrence."
::= { alarmLogEntry 1 }
alarmTag OBJECT-TYPE
SYNTAX INTEGER(1..999)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique tag used to identify the alarm entry."
::= { alarmLogEntry 2 }
alarmLastDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date and time for the most recent alarm occurrence.
If this is the first time occurrence, it would be same
as alarmFirstDateTime."
::= { alarmLogEntry 3 }
alarmEventId OBJECT-TYPE
SYNTAX INTEGER (0..9999)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The event ID assigned to this alarm."
::= { alarmLogEntry 4 }
alarmSeverity OBJECT-TYPE
SYNTAX INTEGER { critical(1), major(2), minor(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The severity of this alarm. Could be critical, major,
or minor."
::= { alarmLogEntry 5 }
alarmSource OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..152))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A five to seven tuple string composed of the
following items: System Name:card type (MPM,
OCMITU, OFCM, etc.). location (L for local,
R[number] for remote with optional station number).
shelf #. slot id[. port #][:link name(optional
depending on card type)][:ring name (optional)]
[:pathname(optional)].
When an event applies to all slots of the whole
chassis, 0 will be displayed for both shelf and slot.
Example: SystemInSunnyvale:OCMITU.L.1.6:ITU23"
::= { alarmLogEntry 6 }
alarmDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A string signifying the cause of the error in natural
language (preferrably English) format."
::= { alarmLogEntry 7 }
alarmCnt OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of times alarm has occurred(from the same source)."
::= { alarmLogEntry 8 }
alarmAck OBJECT-TYPE
SYNTAX INTEGER { acknowledged(1), unacknowledged(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Acknowledge or unacknowledge the active alarm. Ack will
remove its contribution to the external dry contact alarm
closure. Default is unacknowledged."
::= { alarmLogEntry 9 }
alarmClear OBJECT-TYPE
SYNTAX INTEGER { other(1), clear(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An action to clear the alarm from the alarm log. If
alarm persists, another alarm will be sent. A GET
operation would always return other(1)."
::= { alarmLogEntry 10 }
alarmLastChange OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Time ticks in microseconds of when the last change
was made to the alarm log. This includes ack/unack,
clear, and alarm addition/deletion."
::= { alarmLog 3}
-- The elements in the diagnostics subgroup of the traps
diagModeNum OBJECT-TYPE
SYNTAX INTEGER (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of cards in diagnostics mode in the table
below. This counter is automatically set by the
software."
::= { diagnostics 1 }
diagModeTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiagModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each card
in diagnostics mode."
::= { diagnostics 2 }
diagModeEntry OBJECT-TYPE
SYNTAX DiagModeEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { diagLocation, diagShelf, diagSlot }
::= { diagModeTable 1 }
DiagModeEntry ::=
SEQUENCE
{
diagLocation CardLocation,
diagShelf CardShelf,
diagSlot INTEGER,
diagSetMode INTEGER
}
diagLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card: local or remote"
::= { diagModeEntry 1 }
diagShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf in which the card is located."
::= { diagModeEntry 2 }
diagSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The card slot in which the card is located."
::= { diagModeEntry 3 }
diagSetMode OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
warmboot(2),
loopbackDisabled(3),
loopbackEnabled(4),
selftest(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If on, the card will be in diagnostics mode. If
off, the card comes out of diagnostics mode."
::= { diagModeEntry 4 }
diagTestNum OBJECT-TYPE
SYNTAX INTEGER (0..20)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of built-in diagnostics tests in the table
below."
::= { diagnostics 3 }
diagTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF DiagTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
built-in diagnostics test."
::= { diagnostics 4 }
diagTestEntry OBJECT-TYPE
SYNTAX DiagTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { diagTestId, diagTLocation, diagTShelf, diagTSlot }
::= { diagTestTable 1 }
DiagTestEntry ::=
SEQUENCE
{
diagTestId INTEGER,
diagTLocation CardLocation,
diagTShelf CardShelf,
diagTSlot INTEGER,
diagParam1 DisplayString (SIZE (0..30)),
diagParam2 DisplayString (SIZE (0..30)),
diagParam3 DisplayString (SIZE (0..30)),
diagTSetMode FlagType
}
diagTestId OBJECT-TYPE
SYNTAX INTEGER
{
lLoopBack(1),
rLoopBack(2),
lNormal(3),
rNormal(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the built-in diagnostics test."
::= { diagTestEntry 1 }
diagTLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The location of the card to run the test on"
::= { diagTestEntry 2 }
diagTShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The shelf in which the card is located."
::= { diagTestEntry 3 }
diagTSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The card slot in which the card is located."
::= { diagTestEntry 4 }
diagParam1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The first parameter, if any to pass to the built-in
test module. This parameter may be NULL to signify
no run-time parameters. If there is a parameter in,
any data type, it should be passed as a String
equivalent."
::= { diagTestEntry 5 }
diagParam2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The second parameter, if any to pass to the built-in
test module. This parameter may be NULL to signify
no more run-time parameters. If there is a parameter
in any data type, it should be passed as a String
equivalent."
::= { diagTestEntry 6 }
diagParam3 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The third parameter, if any to pass to the built-in
test module. This parameter may be NULL to signify
no more run-time parameters. If there is a parameter
in any data type, it should be passed as a String
equivalent."
::= { diagTestEntry 7 }
diagTSetMode OBJECT-TYPE
SYNTAX FlagType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If on, the given test will be run on the given card.
The value off has no effect in this case and is
ignored."
::= { diagTestEntry 8 }
mcmescSelfTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescSelfTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the self-test results for mcmesc link port."
::= { mcmescSelfTest 1 }
mcmescSelfTestEntry OBJECT-TYPE
SYNTAX McmescSelfTestEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescSelfTestLocation, mcmescSelfTestShelf, mcmescSelfTestSlot }
::= { mcmescSelfTestTable 1 }
McmescSelfTestEntry ::=
SEQUENCE
{
mcmescSelfTestLocation CardLocation,
mcmescSelfTestShelf CardShelf,
mcmescSelfTestSlot INTEGER,
mcmescSelfTestStart INTEGER,
mcmescSelfTestResult INTEGER,
mcmescSelfTestSeqNum DisplayString,
mcmescSelfTestTimeStamp DisplayString
}
mcmescSelfTestLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card: local or remote. The self test
is applicable to local mcmesc only."
::= { mcmescSelfTestEntry 1 }
mcmescSelfTestShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf in which the card is located."
::= { mcmescSelfTestEntry 2 }
mcmescSelfTestSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The card slot in which the card is located."
::= { mcmescSelfTestEntry 3 }
mcmescSelfTestStart OBJECT-TYPE
SYNTAX INTEGER { other(1), yes(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Initiate a self-test. A get on this will always return an other.
Any outstanding loopbacks will be turned off before starting
self-test."
::= { mcmescSelfTestEntry 4 }
mcmescSelfTestResult OBJECT-TYPE
SYNTAX INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate an overall result of the latest self-test.
The value inprogress(3) will be given if a self-test is in progress.
The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult
show the detail result of each individual test item."
::= { mcmescSelfTestEntry 5 }
mcmescSelfTestSeqNum OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate a sequece number associated with the latest
complete self test.
The sring of inprogress will be given if a self-test is in progress.
The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult
show the detail result of each individual test item."
::= { mcmescSelfTestEntry 6 }
mcmescSelfTestTimeStamp OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the time stamp associated with the latest
complete self test.
The value inprogress(3) will be given if a self-test is in progress.
The table mcmescLinkSelfTestResult and mcmescPortSelfTestResult
show the detail result of each individual test item."
::= { mcmescSelfTestEntry 7 }
mcmescLinkSelfTestResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescLinkSelfTestResultEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the self-test results for mcmesc link port."
::= { mcmescSelfTest 2 }
mcmescLinkSelfTestResultEntry OBJECT-TYPE
SYNTAX McmescLinkSelfTestResultEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescLinkSelfTestLocation, mcmescLinkSelfTestShelf, mcmescLinkSelfTestSlot }
::= { mcmescLinkSelfTestResultTable 1 }
McmescLinkSelfTestResultEntry ::=
SEQUENCE
{
mcmescLinkSelfTestLocation CardLocation,
mcmescLinkSelfTestShelf CardShelf,
mcmescLinkSelfTestSlot INTEGER,
mcmescLinkSelfTestTxI2c INTEGER,
mcmescLinkSelfTestCdrI2c INTEGER,
mcmescLinkSelfTestDataPath INTEGER
}
mcmescLinkSelfTestLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card: local or remote. The self test
is applicable to local mcmesc only."
::= { mcmescLinkSelfTestResultEntry 1 }
mcmescLinkSelfTestShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf in which the card is located."
::= { mcmescLinkSelfTestResultEntry 2 }
mcmescLinkSelfTestSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The card slot in which the card is located."
::= { mcmescLinkSelfTestResultEntry 3 }
mcmescLinkSelfTestTxI2c OBJECT-TYPE
SYNTAX INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the link port's Tx I2C self-test result.
The value inprogress(3) will be given if a self-test is in progress."
::= { mcmescLinkSelfTestResultEntry 4 }
mcmescLinkSelfTestCdrI2c OBJECT-TYPE
SYNTAX INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the link port's CDR I2C self-test result.
The value inprogress(3) will be given if a self-test is in progress."
::= { mcmescLinkSelfTestResultEntry 5 }
mcmescLinkSelfTestDataPath OBJECT-TYPE
SYNTAX INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the link port's data path self-test result.
The value inprogress(3) will be given if a self-test is in progress."
::= { mcmescLinkSelfTestResultEntry 6 }
mcmescPortSelfTestResultTable OBJECT-TYPE
SYNTAX SEQUENCE OF McmescPortSelfTestResultEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the self-test results for mcmesc CPE port."
::= { mcmescSelfTest 3 }
mcmescPortSelfTestResultEntry OBJECT-TYPE
SYNTAX McmescPortSelfTestResultEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { mcmescPortSelfTestLocation, mcmescPortSelfTestShelf,
mcmescPortSelfTestSlot, mcmescPortSelfTestPort}
::= { mcmescPortSelfTestResultTable 1 }
McmescPortSelfTestResultEntry ::=
SEQUENCE
{
mcmescPortSelfTestLocation CardLocation,
mcmescPortSelfTestShelf CardShelf,
mcmescPortSelfTestSlot INTEGER,
mcmescPortSelfTestPort INTEGER,
mcmescPortSelfTestTxI2c INTEGER,
mcmescPortSelfTestCdrI2c INTEGER,
mcmescPortSelfTestTxDataPath INTEGER,
mcmescPortSelfTestRxDataPath INTEGER
}
mcmescPortSelfTestLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the card: local or remote. The self test
is applicable to local mcmesc only."
::= { mcmescPortSelfTestResultEntry 1 }
mcmescPortSelfTestShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf in which the card is located."
::= { mcmescPortSelfTestResultEntry 2 }
mcmescPortSelfTestSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The card slot in which the card is located."
::= { mcmescPortSelfTestResultEntry 3 }
mcmescPortSelfTestPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPE port's index."
::= { mcmescPortSelfTestResultEntry 4 }
mcmescPortSelfTestTxI2c OBJECT-TYPE
SYNTAX INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the CPE port's Tx I2C self-test result.
The value inprogress(3) will be given if a self-test is in progress."
::= { mcmescPortSelfTestResultEntry 5 }
mcmescPortSelfTestCdrI2c OBJECT-TYPE
SYNTAX INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the CPE port's CDR I2C self-test result.
The value inprogress(3) will be given if a self-test is in progress."
::= { mcmescPortSelfTestResultEntry 6 }
mcmescPortSelfTestTxDataPath OBJECT-TYPE
SYNTAX INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the CPE port's Tx data path self-test result.
The value inprogress(3) will be given if a self-test is in progress."
::= { mcmescPortSelfTestResultEntry 7 }
mcmescPortSelfTestRxDataPath OBJECT-TYPE
SYNTAX INTEGER { passed(1), failed(2), inprogress(3), notreported(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the CPE port's Rx data path self-test result.
The value inprogress(3) will be given if a self-test is in progress."
::= { mcmescPortSelfTestResultEntry 8 }
-- The elements in the userSecMgmt subgroup of the Security group
usrNumUsers OBJECT-TYPE
SYNTAX INTEGER (0..999)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user Logons in the table below. This
counter is automatically set by the software."
::= { userSecMgmt 1 }
usrSecTable OBJECT-TYPE
SYNTAX SEQUENCE OF UsrSecEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each user
logon entry."
::= { userSecMgmt 2 }
usrSecEntry OBJECT-TYPE
SYNTAX UsrSecEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { usrSecLogonId }
::= { usrSecTable 1 }
UsrSecEntry ::=
SEQUENCE
{
usrSecLogonId LogonID,
usrSecPasswd HashedPasswd,
usrSecRole INTEGER,
usrSecFullName DisplayString (SIZE (0..45)),
usrSecActDateTime DateAndTime,
usrSecLastDateTime DateAndTime,
usrSecSetLastDateTime ResetType
}
usrSecLogonId OBJECT-TYPE
SYNTAX LogonID
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The unique logon ID assigned to each user. This field
should only be written by users that are in the right
security role."
::= { usrSecEntry 1 }
usrSecPasswd OBJECT-TYPE
SYNTAX HashedPasswd
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The hashed password for each unique logon ID. To
turn the user account off, typically the password
is set to some fixed value. Fixed passwords are
not accepted as valid passwords. Since this field
is one-way hashed, it can be safely read without
compromising the security of the system."
::= { usrSecEntry 2 }
usrSecRole OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The role associated with each user logon ID. This is
an index into the system role(s) table."
::= { usrSecEntry 3 }
usrSecFullName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..45))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The full name of the user associated with each unique
logon ID."
::= { usrSecEntry 4 }
usrSecActDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Time & Date of the user account activation."
::= { usrSecEntry 5 }
usrSecLastDateTime OBJECT-TYPE
SYNTAX DateAndTime
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Time & Date of the last user logon to the system"
::= { usrSecEntry 6 }
usrSecSetLastDateTime OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An action to set the Time & Date of the last user
logon to the current systemtime."
::= { usrSecEntry 7 }
-- The elements in the systemSecMgmt subgroup of the Security group
secNumRoles OBJECT-TYPE
SYNTAX INTEGER (0..9999)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of system security roles in the table below.
This counter is automatically set by the software."
::= { systemSecMgmt 1 }
secRoleTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecRoleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
system security role entry."
::= { systemSecMgmt 2 }
secRoleEntry OBJECT-TYPE
SYNTAX SecRoleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { secRole }
::= { secRoleTable 1 }
SecRoleEntry ::=
SEQUENCE
{
secRole EntityName,
secRoleDescr DisplayString (SIZE (0..60))
}
secRole OBJECT-TYPE
SYNTAX EntityName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each row in this table defines a unique security
role."
::= { secRoleEntry 1 }
secRoleDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..60))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The full narrated description of each security Role."
::= { secRoleEntry 2 }
secNumGroups OBJECT-TYPE
SYNTAX INTEGER (0..9999)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of entity groups in the table below.
This counter is automatically set by the software."
::= { systemSecMgmt 3 }
secGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entity group entry."
::= { systemSecMgmt 4 }
secGroupEntry OBJECT-TYPE
SYNTAX SecGroupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { secGroup, secGroupRole }
::= { secGroupTable 1 }
SecGroupEntry ::=
SEQUENCE
{
secGroup EntityName,
secGroupRole EntityName
}
secGroup OBJECT-TYPE
SYNTAX EntityName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each row in this table defines a grouping of entities
or elements from the MIB."
::= { secGroupEntry 1 }
secGroupRole OBJECT-TYPE
SYNTAX EntityName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The containment of this group within a security role.
Under the given schema, each Role may have zero or
more entity groups. Given an entity group, it may
have been contained within one or more roles."
::= { secGroupEntry 2 }
secNumElements OBJECT-TYPE
SYNTAX INTEGER (0..9999)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of elements or entities in the table below.
This counter is automatically set by the software."
::= { systemSecMgmt 5 }
secElementTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecElementEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
entity or element in the MIB."
::= { systemSecMgmt 6 }
secElementEntry OBJECT-TYPE
SYNTAX SecElementEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { secElement }
::= { secElementTable 1 }
SecElementEntry ::=
SEQUENCE
{
secElement EntityName,
secElementAccess INTEGER,
secElementOID DisplayString (SIZE (0..30)),
secElementType INTEGER,
secElementParent EntityName
}
secElement OBJECT-TYPE
SYNTAX EntityName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each row in this table defines an element or entity
from the MIB."
::= { secElementEntry 1 }
secElementAccess OBJECT-TYPE
SYNTAX INTEGER { read(1), write(2), readWrite(3), none(4) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The original access mode for this element from the
MIB."
::= { secElementEntry 2 }
secElementOID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The original SNMP OID for this element from the
MIB."
::= { secElementEntry 3 }
secElementType OBJECT-TYPE
SYNTAX INTEGER { element(1), group(2), table(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The original type for this element from the
MIB."
::= { secElementEntry 4 }
secElementParent OBJECT-TYPE
SYNTAX EntityName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The original parent name for this element from the
MIB. The parent is either a table or a subgroup."
::= { secElementEntry 5 }
secNumElmntGrp OBJECT-TYPE
SYNTAX INTEGER (0..9999)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Number of element-to-group mappings in the table
below. This counter is automatically set by the
software."
::= { systemSecMgmt 7 }
secElmntGrpTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecElmntGrpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
element-to-group mapping."
::= { systemSecMgmt 8 }
secElmntGrpEntry OBJECT-TYPE
SYNTAX SecElmntGrpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { elmntName, grpName }
::= { secElmntGrpTable 1 }
SecElmntGrpEntry ::=
SEQUENCE
{
elmntName EntityName,
grpName EntityName,
elmntGrpAccess INTEGER
}
elmntName OBJECT-TYPE
SYNTAX EntityName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each row in this table defines a mapping of elements
to groups. This column is an index into the
secElementTable."
::= { secElmntGrpEntry 1 }
grpName OBJECT-TYPE
SYNTAX EntityName
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each row in this table defines a mapping of elements
to groups. This column is an index into the
secGroupTable."
::= { secElmntGrpEntry 2 }
elmntGrpAccess OBJECT-TYPE
SYNTAX INTEGER { read(1), write(2), readWrite(3), none(4) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The access mode assigned to each element/group entry.
Under the given schema, each group may have zero or
more MIB elements. Given an element, it may
have been contained within one or more groups. The
access mode specified here defines what is the granted
access mode to the named element contained in this
group. Note, the granted access right can never
exceed that of the actual MIB access privilege."
::= { secElmntGrpEntry 3 }
-- The elements in the radiusSecMgmt subgroup of the Security group
radiusAuthOrder OBJECT-TYPE
SYNTAX INTEGER
{
local(1),
radius(2),
localRadius(3),
radiusLocal(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The authentication order used when validating a user
login id and password."
::= { radiusSecMgmt 1 }
radiusNasIdentifier OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"NAS-Identifier for the MPM."
::= { radiusSecMgmt 2 }
radiusDefaultRealm OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Default realm used for radius authentication. This
realm is not used for local authentication."
::= { radiusSecMgmt 3 }
radiusTimeout OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Timeout when sending an authentication request to
a radius server."
::= { radiusSecMgmt 4 }
radiusRetries OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of times to resend requests when a timeout
occurs."
::= { radiusSecMgmt 5 }
radiusSecTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadiusSecEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Radius server table."
::= { radiusSecMgmt 6 }
radiusSecEntry OBJECT-TYPE
SYNTAX RadiusSecEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { radiusServerIndex }
::= { radiusSecTable 1 }
RadiusSecEntry ::=
SEQUENCE
{
radiusServerIndex INTEGER,
radiusServerAddress IpAddress,
radiusServerPort INTEGER,
radiusServerSecret DisplayString
}
radiusServerIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index into the radius server table. This index also
specifies the server order used for sending authentication
requests."
::= { radiusSecEntry 1 }
radiusServerAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IP address of the radius server. Setting the address to
0 will delete the server entry."
::= { radiusSecEntry 2 }
radiusServerPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Radius port used for authentication requests."
::= { radiusSecEntry 3 }
radiusServerSecret OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..48))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Secret shared with authentication server."
::= { radiusSecEntry 4 }
radiusAddServer OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Add server to the server table. Servers are added
to the first available entry in the server table. To
add a server provide server IP address, radius port,
and shared secret in the format '<ip address>,<port>,
<secret>'. All fields are required. a get on this
element will return '0,0,0'."
::= { radiusSecMgmt 7 }
-- The elements in the sshSecMgmt subgroup of the Security group
sshMode OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables or disables the SSH server. Enabling
SSH will disable the built in telnet server.
Disabling SSH will enable the telnet server."
::= { sshSecMgmt 1 }
sshKeySize OBJECT-TYPE
SYNTAX INTEGER (512..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The size (in bits) of the DSS key to generate.
Key size must be a multiple of 8 and between 512
and 1024 bits."
::= { sshSecMgmt 2 }
sshMaxSessions OBJECT-TYPE
SYNTAX INTEGER (1..6)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum number of SSH sessions that can be
active at one time. Setting this element will
also affect the number of telnet sessions that
can be active at a time."
::= { sshSecMgmt 3 }
sshGenKey OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
genDssKey(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this element to genDssKey(2) will cause a
new DSS key to be generated. The process of
generating a new key can take some time (several
minutes) and may cause significant system slowdown
until the process is complete. Reading this element
will always return other(1)."
::= { sshSecMgmt 4 }
-- The elements in the cpAcct subgroup of the accounting group
acctCPTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcctCPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
system accounting data maintained for each CP."
::= { cpAcct 1 }
acctCPEntry OBJECT-TYPE
SYNTAX AcctCPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { acctCPShelf, acctCPSlot }
::= { acctCPTable 1 }
AcctCPEntry ::=
SEQUENCE
{
acctCPShelf CardShelf,
acctCPSlot INTEGER,
acctCPDsgnAct Counter,
acctCPDsgnStdby Counter,
acctCPActive Counter,
acctCPStandby Counter,
acctCPUpTime Counter,
acctCPUnAvail Counter,
acctCPResetCntrs ResetType
}
acctCPShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf in which the given CP card is placed."
::= { acctCPEntry 1 }
acctCPSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot in which the given CP card is placed."
::= { acctCPEntry 2 }
acctCPDsgnAct OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The total time this CP has been designated Active"
::= { acctCPEntry 3 }
acctCPDsgnStdby OBJECT-TYPE
SYNTAX Counter
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The total time this CP has been designated Standby"
::= { acctCPEntry 4 }
acctCPActive OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time this CP has actually been the primary"
::= { acctCPEntry 5 }
acctCPStandby OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time this CP has actually been the standby"
::= { acctCPEntry 6 }
acctCPUpTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time since this CP has been commissioned"
::= { acctCPEntry 7 }
acctCPUnAvail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time this CP has not been available due
to an alarm, diag testing or being put offline"
::= { acctCPEntry 8 }
acctCPResetCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If reset, the CP accounting counters will be reset to 0.
A get on this will always return other."
::= { acctCPEntry 9 }
-- The elements in the ccAcct subgroup of the accounting group
acctCCTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcctCCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
system accounting data maintained for each CC."
::= { ccAcct 1 }
acctCCEntry OBJECT-TYPE
SYNTAX AcctCCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { acctCCLocation, acctCCShelf, acctCCSlot }
::= { acctCCTable 1 }
AcctCCEntry ::=
SEQUENCE
{
acctCCLocation CardLocation,
acctCCShelf CardShelf,
acctCCSlot INTEGER,
acctCCUpTime Counter,
acctCCUnAvail Counter,
acctCCResetCntrs ResetType
}
acctCCLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the CC card: local or remote."
::= { acctCCEntry 1 }
acctCCShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf in which the given CC card is placed."
::= { acctCCEntry 2 }
acctCCSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot in which the given CC card is placed."
::= { acctCCEntry 3 }
acctCCUpTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time since this CC has been commissioned"
::= { acctCCEntry 4 }
acctCCUnAvail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time this CC has not been available due
to an alarm, diag testing or being put offline"
::= { acctCCEntry 5 }
acctCCResetCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If reset, the CC accounting counters will be reset to 0.
A get on this will always return other."
::= { acctCCEntry 6 }
-- The elements in the mcmAcct subgroup of the accounting group
acctmcmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcctmcmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
system accounting data maintained for each MCMT1/MCME1."
::= { mcmAcct 1 }
acctmcmEntry OBJECT-TYPE
SYNTAX AcctmcmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { acctmcmLocation, acctmcmShelf, acctmcmSlot }
::= { acctmcmTable 1 }
AcctmcmEntry ::=
SEQUENCE
{
acctmcmLocation CardLocation,
acctmcmShelf CardShelf,
acctmcmSlot INTEGER,
acctmcmUpTime Counter,
acctmcmUnAvail Counter,
acctmcmResetCntrs ResetType
}
acctmcmLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the MCMT1/MCME1 card: local or remote."
::= { acctmcmEntry 1 }
acctmcmShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf in which the given MCMT1/MCME1 card is placed."
::= { acctmcmEntry 2 }
acctmcmSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot in which the given MCMT1/MCME1 card is placed."
::= { acctmcmEntry 3 }
acctmcmUpTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time since this MCMT1/MCME1 has been commissioned"
::= { acctmcmEntry 4 }
acctmcmUnAvail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time this MCMT1/MCME1 has not been available due
to an alarm, diag testing or being put offline"
::= { acctmcmEntry 5 }
acctmcmResetCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If reset, the MCMT1/MCME1 accounting counters will be
reset to 0. A get on this will always
return other."
::= { acctmcmEntry 6 }
-- The elements in the mcmescAcct subgroup of the accounting group
acctmcmescTable OBJECT-TYPE
SYNTAX SEQUENCE OF AcctmcmescEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table represents the information for each
system accounting data maintained for each MCMESC."
::= { mcmescAcct 1 }
acctmcmescEntry OBJECT-TYPE
SYNTAX AcctmcmescEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Specifies the index for each row in the table below"
INDEX { acctmcmescLocation, acctmcmescShelf, acctmcmescSlot }
::= { acctmcmescTable 1 }
AcctmcmescEntry ::=
SEQUENCE
{
acctmcmescLocation CardLocation,
acctmcmescShelf CardShelf,
acctmcmescSlot INTEGER,
acctmcmescUpTime Counter,
acctmcmescUnAvail Counter,
acctmcmescResetCntrs ResetType
}
acctmcmescLocation OBJECT-TYPE
SYNTAX CardLocation
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The location of the MCMESC card: local or remote."
::= { acctmcmescEntry 1 }
acctmcmescShelf OBJECT-TYPE
SYNTAX CardShelf
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The shelf in which the given MCMESC card is placed."
::= { acctmcmescEntry 2 }
acctmcmescSlot OBJECT-TYPE
SYNTAX CardSlot
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot in which the given MCMESC card is placed."
::= { acctmcmescEntry 3 }
acctmcmescUpTime OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time since this MCMESC has been commissioned."
::= { acctmcmescEntry 4 }
acctmcmescUnAvail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total time this MCMESC has not been available due
to an alarm, diag testing or being put offline."
::= { acctmcmescEntry 5 }
acctmcmescResetCntrs OBJECT-TYPE
SYNTAX ResetType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If reset, the MCMESC accounting counters will be reset to 0. A get
on this will always return other."
::= { acctmcmescEntry 6 }
-- The Generic Trap supported by the LuxN MIB.
luxNGenericTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This is a generic trap identifying an event for
a given event source. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1
luxNVoadmDetectorFailureTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a failure is detected on the
VOADM power monitor. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1001
luxNVoadmDetectorFailureResolvedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a failure on the VOADM power
monitor has been resolved. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1002
luxNVoadmOutofRangeTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the user configured settings
for a VOADM would force the power levels to be outside
of allowed operating ranges for the current link
conditions. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1003
luxNVoadmOutofRangeResolvedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an existing VOADM out of range
condition is resolved. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1004
luxNsignalStrengthHighTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the receieve signal
strength is high. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1005
luxNsignalStrengthLowTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the receieve signal
strength is low. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1006
luxNsignalStrengthNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the receieve signal
strength is normal. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1007
luxNlaserPowerOutOfRangeTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon detection of out of range
laser power. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1008
luxNlaserPowerNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon detection of normal
laser power. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1009
luxNberHighThresholdExceeded TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon detecting that MCMESC's BER high threshold is
exceeds. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. The port number 1 to 12 is applicable to CPE ports, a NULL
port number indicates the link.
Each event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1010
luxNberHighThresholdExceededNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon detecting that MCMESC's BER high threshold is
not exceeded. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. The port number 1 to 12 is applicable to CPE ports, a NULL
port number indicates the link.
Each event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1011
luxNberModerateThresholdExceeded TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon detecting that MCMESC's BER moderate threshold
is exceeded. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. The port number 1 to 12 is applicable to CPE ports, a NULL
port number indicates the link.
Each event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1012
luxNberModerateThresholdExceededNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon detecting that MCMESC's BER moderate threshold
is not exceeded. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. The port number 1 to 12 is applicable to CPE ports, a NULL
port number indicates the link.
Each event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 1013
luxNSNMPKeepalive TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent out periodicly by the MPM when SNMP keep alive
functionality is enabled."
::= 2000
luxNSNMPKeepalivesEnabled TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon SNMP keep alive functionality being enabled"
::= 2001
luxNSNMPKeepalivesDisabled TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon SNMP keep alive functionality being disabled"
::= 2002
luxNSNMPKeepaliveIntervalChanged TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the SNMP keep alive interval is modified"
::= 2003
luxNTelnetClientEnabled TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"Telnet client has been enabled for active telnet sessions"
::= 2004
luxNTelnetClientDisabled TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"Telnet client has been disabled for active telnet sessions"
::= 2005
luxNsnmpAuthenticationFailureTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon receipt of invalid
community strings. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2017
luxNcoldStartTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the device has reinitialized
itself. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2018
luxNwarmStartTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the device has undergone
a warm boot. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2019
luxNlossOfLightResolvedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of light condition
has been resolved. For OCM/MCMT1/MCME1, it indicates that the link between two
optically connected channel cards is up.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2021
luxNlossOfLightDetectedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of light condition
has been detected. For OCM/MCMT1/MCME1, it indicates that the link between two
optically connected channel cards is down.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2022
luxNntpEnableTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when NTP is enabled.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2023
luxNntpDisableTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when NTP is disabled.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2024
luxNntpTimeServerChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the NTP time
server is changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2025
luxNntpUpdateIntervalChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the NTP update
interval is changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2026
luxNtimeZoneChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the system time
zone is changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2027
luxNspiConnectionUpTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"Obsolete. This trap is sent when SPI communications
has been established with a card specified in the
source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2030
luxNcardLostTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when SPI communications has been
lost with a card specified in the source field.
The reason is either that the card has been physically
removed or there exist a failure condition.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2031
luxNConfigChangeTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a configuration change
has ocurred for a card specified in the source
field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2034
luxNstatsPollFailedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when statistics data can no longer
be gathered from a card in the specified source
field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2035
luxNCardFoundTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a card has been
discovered in the chassis.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2040
luxNlocalLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the local loopback mode
has been enabled for a channel card in the
specified source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2041
luxNremoteLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the remote loopback mode
has been enabled for a channel card in the
specified source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2042
luxNlocalLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the local loopback mode
has been disabled for a channel card in the
specified source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2043
luxNremoteLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the remote loopback mode
has been disabled for a channel card in the
specified source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2044
luxNftpSessionInitiatedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a ftp session has been
initiated from the CLI. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2047
luxNuserResetStatusTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"Obsolete. This trap is sent when the status information
for a card specified in the source field has
been modified via the snmp agent.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2050
luxNprotectionSwitchTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a protection switch has
occurred either automatically or manually.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2051
luxNipAddressErrorTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"Obsolete. This trap is sent when an error has
occurred while configuring the IP address.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2052
luxNipNetmaskErrorTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"Obsolete. This trap is sent when an error has
occurred while configuring the Netmask.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2053
luxNdefaultGatewayErrorTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"Obsolete. This trap is sent when an error has
occurred while configuring the default gateway.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2054
luxNlossOfSignalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of signal is
detected on one of the ports on a channel card
specified in the source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2055
luxNlossOfSignalNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of signal problem
on one of the ports on a channel card
specified in the source field has been corrected.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2056
luxNlossOfFrameTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of frame error
condition is detected on one of the ports on a
channel card specified in the source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2057
luxNlossOfFrameNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of frame error
condition on one of the ports on a channel card
specified in the source field has been corrected.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2058
luxNrecvAISTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a receive AIS (Alarm
Indication Signal) is detected on one of the ports
on a channel card specified in the source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2059
luxNrecvAISNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a receive AIS (Alarm
Indication Signal) problem on one of the ports
on a channel card specified in the source field
has been corrected. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2060
luxNrecvYellowAlarmTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a receive receive yellow
alarm is detected on one of the ports on a channel
card specified in the source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2061
luxNrecvYellowAlarmNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a receive receive yellow
alarm problem on one of the ports on a channel
card specified in the source field has been
corrected. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2062
luxNlineCodeViolationTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a line code violation error
condition is detected on one of the ports on a
channel card specified in the source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2063
luxNlineCodeViolationNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a line code violation error
condition on one of the ports on a channel card
specified in the source field has been corrected.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2064
luxNframingAlarmTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a framing alarm is
detected on one of the ports on a channel card
specified in the source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2065
luxNframingAlarmNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a framing alarm problem
on one of the ports on a channel card specified
in the source field has been corrected.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2066
luxNlossOfTimingTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of timing condition
is detected on a channel card specified in
the source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2067
luxNlossOfTimingNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of timing problem
on a channel card specified in the source field
has been corrected. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2068
luxNselfTestFailTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a self-test failure
is detected on a channel card specified in
the source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2073
luxNselfTestPassTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a successful self-test
is detected on a channel card specified in
the source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2074
luxNIbmDownTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a problem is detected on a
inband management link. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2075
luxNIbmNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a problem is resolved on a
inband management link. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2076
luxNnearendCardLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a near-end card
loopback has been enabled on an mcmt1/mcme1 or mcmesc card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2077
luxNnearendCardLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a near-end card
loopback has been disabled on an mcmt1/mcme1 or mcmesc card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2078
luxNnetworkPortLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a network port
loopback has been enabled on an mcmt1/mcme1 or mcmesc card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2079
luxNnetworkPortLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a network port
loopback has been disabled on an mcmt1/mcme1 or mcmesc card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2080
luxNnetworkCardLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a network card
loopback has been enabled on an mcmt1/mcme1 or mcmesc card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2081
luxNnetworkCardLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a network card
loopback has been disabled on an mcmt1/mcme1 or mcmesc card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2082
luxNnearendPortLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a nearend port
loopback has been enabled on an mcmt1/mcme1 or mcmesc card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2083
luxNnearendPortLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a nearend port
loopback has been disabled on an mcmt1/mcme1 or mcmesc card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2084
luxNpowerSupplyNotPresentTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the power supply
specified in the source field is not present.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2085
luxNpowerSupplyOKTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the power supply
specified in the source field is performing
properly. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2086
luxNpowerSupplyDegradedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the performance
of the power supply specified in the source field
has degraded. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2087
luxNpowerSupplyFailureTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the power
supply specified in the source field has failed.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2088
luxNfanOKTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the fan
specified in the source field is performing
properly. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2089
luxNfanFailureTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the fan
specified in the source field has failed.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2090
luxNcsimDataUnavailableTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the ColorSIM
module as specified in the source field is in
a Data Unavailable state.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2091
luxNcsimDataAvailableTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the ColorSIM
module as specified in the source field is in
a Data Available state.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2092
luxNcsimModuleFailureTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the ColorSIM
module as specified in the source field has
failed to operate properly.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2093
luxNethernetLossOfCarrierTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that loss of carrier
has been detected on the CPE's ethernet port.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2094
luxNethernetCarrierDetectedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the carrier
has been detected on the CPE's ethernet port.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2095
luxNtimingPriorityChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the timing
priority for a card has been changed.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2096
luxNopenFiberCPEAlarmTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an open fiber condition
on the CPE has been detected from a
card specified in the source field. The
source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2097
luxNopenFiberCPEAlarmResolvedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an open fiber condition
on the CPE has been resolved from a
card specified in the source field. The
source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2098
luxNstandbyMPMDetectedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the standby MPM card
has been detected. The
source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2099
luxNstandbyMPMLostTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the standby MPM card
has been lost. The
source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2100
luxNprotectionLinkFailureTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the protection link has
become unaviable due to either low receive power
level or an open fiber condition. The
source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2101
luxNprotectionLinkFailureResolvedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the protection link
has become available as a result of a corrective
action to resolve a previous failure condition.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2102
luxNtopologyDatabaseChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent whenever a link has either been
added or deleted from the topology database.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2103
luxNredundantDatabaseCopyComplete TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon completion of a forced redundant database
copy. The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2104
luxNredundantDatabaseCopyFailed TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a failure occurs during a
forced redundant database copy. The source is a
4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2105
luxNimageExportInProgressTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an module image is being
exported from the MPM through ftp.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2106
luxNimageExportSuccessTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module image exported from
the MPM through ftp has been completed successfully.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2107
luxNimageExportFailedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module image exported
from the MPM through ftp has failed.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2108
luxNunknownCardTypeDetectedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module with an unknown
card type is detected.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2109
luxNosamBiasCurrentOverLimitTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's bias current
exceeds 90% of allowed maximum.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2110
luxNosamBiasCurrentNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's bias current
is within normal range.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2111
luxNosamTecCurrentOverLimit TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's TEC current
is above the specified limit.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2112
luxNosamTecCurrentNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's TEC current
is within normal range.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2113
luxNosamLaserTemperatureDrift TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's laser temperature
drifts by more than +/- 2 degree Celsius.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2114
luxNosamLaserTemperatureStable TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's laser temperature
no longer drifts.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2115
luxNosamMaxInputPowerReached TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's input power
is greater than or equal to 9 dBm.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2116
luxNosamInputPowerBackDownNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's input power
has fallen within normal range.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2117
luxNosamMaxOutputPowerReached TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's output power
is greater than or equal to 13 dBm.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2118
luxNosamOutputPowerNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's output power
is within normal range.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2119
luxNosamOpticalGainDeltaExceeded TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's gain delta
is greater than or equal to 4 dB.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2120
luxNosamOpticalGainDeltaNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's gain delta
is less than 4 dB.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2121
luxNosamMinInputPowerBelowLimit TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's input power is
less than or equal to -30 dBm.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2122
luxNosamInputPowerBackUpNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's input power
has risen within normal range.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2123
luxNosamSingleAprSensorFailed TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's APR sensor is
not functioning.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2124
luxNosamSingleAprSensorNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the osam's APR sensor has
become functional.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2125
luxNosamDualAprSensorFailed TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when both of the osam's APR sensors
are not functioning.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2126
luxNosamDualAprSensorNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when both of the osam's APR sensors
has become functional.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2127
luxNosamFiberDisconnected TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a fiber disconnect condition
has been detected on an osam module.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2128
luxNosamFiberConnected TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a fiber connect condition
has been detected after a fiber disconnect on an osam
module. The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2129
luxNosamControlChanged TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when either the current control or
gain control has been changed.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2130
luxNosamLaserModuleOn TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the laser module has
been turned on by the osam firmware.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2131
luxNosamLaserModuleOff TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the laser module has
been turned off by the osam firmware.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2132
luxNipAuthenticationFailure TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"Not yet supported. This trap is sent when access
from an invalid IP address based on the ACL has
been detected.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2133
luxNftpCompletedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the ftp session has
been disconnected.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2134
luxNftpHostFailedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the MPM is unable to
connect to the ftp host.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2135
luxNimageUpdateInProgressTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an module image is being
downloaded to MPM through ftp.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2136
luxNimageUpdateSuccessTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module image download to
MPM through ftp has been completed successfully.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2137
luxNimageUpdateFailedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module image download
to MPM through ftp has failed.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2138
luxNmoduleUpdateInProgressTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module image is being
transferred from the MPM to the module.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2139
luxNmoduleUpdateSuccessTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module image transfer
from the MPM to the module has been completed
successfully.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2140
luxNmoduleUpdateFailedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module image transfer
from the MPM to the module has failed.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2141
luxNethernetLinkFailure TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon detection of the ethernet
link failure on the MPM.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2142
luxNethernetLinkFailureResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent upon resolution of the ethernet
link failure on the MPM.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2143
luxNfanNotPresentTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the fan
specified in the source field is not present
in the system. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2144
luxNcardMismatchTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a card mismatch is found in a given slot.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2145
luxNpwrFeedLowVoltageTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the DC voltage level on the power feed
reaches very close to the shutdown voltage.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2146
luxNpwrFeedLowVoltageRecoveryTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the DC voltage level on the power feed
recovers from the low voltage level condition .
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2147
luxNpwrFeedOKTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the DC voltage level on the power feed
is within the operating window of the chassis .
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2148
luxNpwrFeedFailureTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the DC voltage level on the power feed
is either too low or too high to operate the chassis
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2149
luxNpwrFeedBrkOpenTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a user manually flips open the breaker relay
switch attached to that feed.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2150
luxNextCritAlmInpTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an alarm gets generated at an external
alarm input that is configured for critical severity.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply, fan and ext. alarm input,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2151
luxNextMajAlmInpTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an alarm gets generated at an external
alarm input that is configured for majority severity.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply, fan and ext. alarm input,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2152
luxNextMinorAlmInpTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an alarm gets generated at an external
alarm input that is configured for minor severity.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply, fan and ext. alarm input,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2153
luxNextClearAlmInpTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an alarm gets cleared at an external
alarm input.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply, fan and ext. alarm input,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2154
luxNpwrFeedOverVoltageTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the DC voltage level on the power feed
reaches very close to the shutdown voltage on the higher side.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2155
luxNpwrFeedOverVoltageRecoveryTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the DC voltage level on the power feed
recovers from the over voltage level condition .
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2156
luxNstandbySWMismatchTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when there is a mismatch between the software version of
standby and active MPM.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2157
luxNstandbyDBNotSupportedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the standby MPM do not
support Active MPM's database.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2158
luxNactiveStandbySWAlignedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the software version between
standby and active MPM is aligned.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2159
luxNactiveStandbyDBAlignedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the database version between
standby and active MPM is aligned.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2160
luxNmcmescTestSequenceOnTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the test-sequence is set to ON
on an MCMESC card specified in the source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. The port number 1 to 12 is applicable to CPE ports, a NULL
port number indicates the link.
Each event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2161
luxNmcmescTestSequenceOffTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the test-sequence is set to OFF
on an MCMESC card specified in the source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. The port number 1 to 12 is applicable to CPE ports, a NULL
port number indicates the link.
Each event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2162
luxNselfTestStartedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when self-test
has started for a channel card in the
specified source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2163
luxNselfTestEndedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when self-test
has ended for a channel card in the
specified source field. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2164
luxNvoadmMuxSetPointOutOfRange TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a VOADM module has detected that the
recently configured mux set point value would bring down the fibre
if applied. The set point value is rejected and the MPM and
module returns to the previously configured mux set point.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2165
luxNvoadmDemuxForceConfig TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a VOADM module forces its Demux configuration
into fixed power mode. Forcing the Demux mode to fixed power mode
can only occur when the Demux ports are configured for fixed
attentuation mode and network conditions change sufficently
that the current configuration may cause damage to the laser.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2166
luxNSfpNotPresent TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a missing SFP is detect.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2167
luxNSfpPresent TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a SFP has been inserted into the
module .The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each event
has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2168
luxNSfpFailure TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a SFP failure is detected.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2169
luxNSfpFailureResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a SFP failure is resolved.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2170
luxNSfpNotAuthorized TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an unauthorized SFP is detected.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2171
luxNSfpAuthorized TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an unauthorized SFP is replaced with
an authorized SFP. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and optionally the port
number of the source of the event. In the case of the
power supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2172
luxNSfpRateMismatch TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a SFP does not supported the user
configured line rate. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and optionally the port
number of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each event has
an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2173
luxNSfpRateMismatchResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a SFP that does not support the user
configured line rate is replaced with an SFP that does.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2174
luxNLinkRxSignalDegraded TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the packet error rate increases over
10e-4. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each event
has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2175
luxNLinkRxSignalDegradedResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the packet error rate falls below
10e-4. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each event
has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2176
luxNLinkTxFault TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a Tx fault is detect on the link port.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2177
luxNLinkTxFaultResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a Tx fault is resolved on the link port.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2178
luxNPortTxFault TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a Tx fault is detect on a CPE port.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2179
luxNPortTxFaultResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a Tx fault is resolved on a CPE port.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2180
luxNXfpNotPresent TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a missing XFP is detect.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2181
luxNXfpPresent TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a XFP has been inserted into the
module .The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each event
has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2182
luxNXfpFailure TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a XFP failure is detected.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2183
luxNXfpFailureResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a XFP failure is resolved.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2184
luxNXfpNotAuthorized TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an unauthorized XFP is detected.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2185
luxNXfpAuthorized TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an unauthorized XFP is replaced with
an authorized XFP. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and optionally the port
number of the source of the event. In the case of the
power supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2186
luxNXfpRateMismatch TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a XFP does not supported the user
configured line rate. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and optionally the port
number of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each event has
an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2187
luxNXfpRateMismatchResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a XFP that does not support the user
configured line rate is replaced with a XFP that does.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2188
luxNCpeXfpNotPresent TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a missing XFP is detect for a CPE port.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2189
luxNCpeXfpPresent TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a XFP has been inserted into the
module CPE port.The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and optionally the
port number of the source of the event. In the case of
the power supply and fan, the shelf number is set to 0.
Each event has an unique event ID. It also has a preset
event severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2190
luxNCpeXfpFailure TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a CPE XFP failure is detected.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2191
luxNCpeXfpFailureResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a CPE XFP failure is resolved.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2192
luxNCpeXfpNotAuthorized TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an unauthorized XFP is detected in a
CPE prot. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number of
the source of the event. In the case of the power supply
and fan, the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2193
luxNCpeXfpAuthorized TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an unauthorized XFP is replaced with
an authorized XFP in a CPE port. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and optionally
the port number of the source of the event. In the case of the
power supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2194
luxNCpeXfpRateMismatch TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a CPE XFP does not supported the user
configured line rate. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and optionally the port
number of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each event has
an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2195
luxNCpeXfpRateMismatchResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a CPE XFP that does not support the
user configured line rate is replaced with an XFP that does.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2196
luxNOutOfFrame TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an out of frame error is detected.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2197
luxNOutOfFrameResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an out of frame error is resolved.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2198
luxNCpeLossOfFrame TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of frame error is detected on
a CPE port. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number of
the source of the event. In the case of the power supply
and fan, the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2199
luxNCpeLossOfFrameResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a loss of frame error is resolved on
a CPE port. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number of
the source of the event. In the case of the power supply
and fan, the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2200
luxNCpeOutOfFrame TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an out of frame error is detected on
a CPE port. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number of
the source of the event. In the case of the power supply
and fan, the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2201
luxNCpeOutOfFrameResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an out of frame error is resolved on
a CPE port. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number of
the source of the event. In the case of the power supply
and fan, the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2202
luxNCdrFailure TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a CDR failure is detected.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2203
luxNCdrFailureResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a CDR failure is resolved.
The source is a 4 or 5 tuple specifying the type, location,
shelf, slot ID, and optionally the port number of the source
of the event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2204
luxNBitError10Em3 TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the modules bit error rate exceeds
10E-3. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2205
luxNBitError10Em3Resolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the modules bit error rate falls below
10E-3. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2206
luxNBitError10Em4 TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the modules bit error rate exceeds
10E-4. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2207
luxNBitError10Em4Resolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the modules bit error rate falls below
10E-4. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2208
luxNBitError10Em6 TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the modules bit error rate exceeds
10E-6. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2209
luxNBitError10Em6Resolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the modules bit error rate falls below
10E-6. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2210
luxNBitError10Em7 TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the modules bit error rate exceeds
10E-7. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2211
luxNBitError10Em7Resolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the modules bit error rate falls below
10E-7. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2212
luxNAisReceived TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when AIS-L is received on the port.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2213
luxNAisReceivedResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when AIS-L is no longer received on the
port. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2214
luxNAisTransmitted TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when starts transmitting on the port.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2215
luxNAisTransmittedResolved TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when is no longer transmitting on the
port. The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2216
luxNcaseTemperatureHiTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when case temperature is HI.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2225
luxNcaseTemperatureNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when case temperature is normal.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2226
luxNcaseTemperatureLoTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when case temperature is LO.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2227
luxNcaseTemperatureLoNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when case temperature is normal.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2228
luxNpumpTemperatureHiTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when pump temperature is HI.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2229
luxNpumpTemperatureNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when pump temperature is normal.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2230
luxNcoilTemperatureHiTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when coil temperature is HI.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2231
luxNcoilTemperatureNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when coil temperature is normal.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2232
luxNlossOutputPowerTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when loss of output power (or gain) is detected.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2233
luxNlossOutputPowerNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when loss of output power (or gain) is normal.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2234
luxNreflectedOutputPowerHiTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when excessive reflected output power is detected.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2235
luxNreflectedOutputPowerNormalTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when reflected output power is normal.
The source is a 4 or 5 tuple specifying the type,
location, shelf, slot ID, and optionally the port number
of the source of the event. In the case of the power
supply and fan, the shelf number is set to 0. Each
event has an unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 2236
luxNlineRateNotSuppoted TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the module hardware
does not support the configured line rate.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3001
luxNmpmBootImageChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the executable
image for the MPM has been changed. Upon reset of
the MPM card, this new bootfile will be used.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3002
luxNdateTimeSetTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the date and
time of the system has been changed.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3003
luxNuserAddedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a new user
has been added to the system.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3004
luxNuserDeletedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a user
has been deleted from the system.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3005
luxNuserPasswordChangeTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the password
of one of the user's has been changed.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3006
luxNuserLevelModifiedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the privilege
level of one of the user's has been changed.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3007
luxNsystemNameChangeTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the name of
the system has been changed.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3008
luxNcardAddedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a new card has
been added to the system through either CLI/SNMP
in the specified source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3009
luxNcardDeletedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a card has
been deleted from the system through either
CLI/SNMP in the specified source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3010
luxNmpmRedundancySwitchOverTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a mpm
switchover has occurred.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3011
luxNconnectionAddedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a connectino
has been added to an ofcm/ofcd card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3012
luxNconnectionDeletedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a connection
has been deleted from an ofcm/ofcd card.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3013
luxNipAddressChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the IP address
has been changed successfully.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3014
luxNipNetmaskChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the netmask
has been changed successfully.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3015
luxNdefaultGatewayChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the default
gateway has been changed successfully.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3016
luxNGetCommunityChangeTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the getcommunity
has been changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3017
luxNSetCommunityChangeTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the setcommunity
has been changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3018
luxNModuleResetTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a module has
been reset. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3019
luxNtopologyRediscoveredTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the topology
database has been rediscovered which is triggered
through either CLI or snmp. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3020
luxNcolorsimEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the ColorSIM
feature has been enabled. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3021
luxNcolorsimDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the ColorSIM
feature has been disabled. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3022
luxNautoCutoffEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the auto cutoff
feature has been enabled. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3023
luxNautoCutoffDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the auto cutoff
feature has been disabled. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3024
luxNextAlarmsEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the external
alarm closures have been enabled. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3025
luxNextAlarmsDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the external
alarm closures have been disabled. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3026
luxNdlModuleActivatedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a module
activation, switching to another module image
version, has occurred.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3027
luxNhttpEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the http
server has been enabled. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3032
luxNhttpDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the http
server has been disabled. The source is a
4 or 5 tuple specifying the type, location,
shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3033
luxNstaticRouteAddedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a new route has
been added to the system through either CLI/SNMP
in the specified source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure. The eveDescr field consists of
trap description and the route information - local CC shelf, slot
and destination IP address"
::= 3034
luxNstaticRouteDeletedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a route has
been deleted from the system through either CLI/SNMP
in the specified source field.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure. The eveDescr field consists of
trap description and the route information - local CC shelf, slot
and destination IP address"
::= 3035
luxNupsrProtectionSwitchOverSrc TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that UPSR protection switch over occurred
on the source either through SNMP or CLI. If the module type is OCM
for this trap, then after issuing this trap it goes into standby mode.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3036
luxNupsrProtectionSwitchOverDest TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that UPSR protection switch over occurred
on the destination either through SNMP or CLI. If the module type is OCM
for this trap, then after issuing this trap it goes into active mode
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3037
luxNimnIpAddressChanged TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a IMN Ip address is successfully
changed either through SNMP or CLI.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3038
luxNupsrNormal TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that UPSR is successfully
enabled either through SNMP or CLI on the system.
This is done once UPSR functionality is normal on the
system.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3039
luxNupsrDegraded TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that UPSR is successfully
disabled either through SNMP, CLI or SPI driver on the system.
This is done after the UPSR functionality on the system is degraded
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3040
luxNusrOneAlarmAction TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that user has performed acknowledgment/
unacknowledgment/Clearing of a single alarm in the alarm log either
through SNMP or CLI .
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3041
luxNusrAllAlarmAction TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that user has performed acknowledgment/
unacknowledgment/Clearing of all alarms in the alarm log either through
SNMP or CLI .
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3042
luxNringConfigurationChanged TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the user has changed the
ring configuration either through deletion or addition of
ringId or pathId.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure. The eveDescr field consists of
trap description and the cross connect information "
::= 3047
luxNeventLogCleared TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that the user has cleared the
event log either through CLI or SNMP.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3048
luxNextAlarmInpTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an user sets up alarm severity
(crit/maj/minor/disable) on external alarm input.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply, fan and ext. alarm input,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3049
luxNextAudioAlarmTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when an user enables or disables audio alarm.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply, fan and ext. alarm input,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3050
luxNTrapHostConfigChangeTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a trap host is added, deleted, or
modified (port configuration).
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3051
luxNTrapHostImnRouteEnabled TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
""
::= 3052
luxNTrapHostImnRouteDisabled TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
""
::= 3053
luxNTrapHostAutoUpdateEnabled TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
""
::= 3054
luxNTrapHostAutoUpdateDisabled TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
""
::= 3055
luxNTrapPathAdded TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a path is configured.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply, fan and ext. alarm input,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3056
luxNTrapPathDeleted TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a path is deleted.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply, fan and ext. alarm input,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3057
luxNdlModuleActivateFailedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a module activation,
switching to another module image version,
has failed.
The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3058
luxNLogServerAddedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a syslog server has been
added. The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3059
luxNLogServerDeletedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a syslog server has been
deleted. The source is a 4 or 5 tuple specifying the
type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3060
luxNLogMaskChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the syslog mask has been
changed. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3061
luxNRadiusAuthChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the radius authentication order
has been changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3062
luxNRadiusDefaultRealmChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the radius default realm
has been changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3063
luxNRadiusNasIdChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the radius NAS Identifier
has been changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3064
luxNRadiusRetriesChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the radius retries has been
changed. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3065
luxNRadiusServerAddedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when a radius server has been
added. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3066
luxNRadiusServerDeletedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when radius server has been
deleted. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3067
luxNRadiusServerModifiedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when radius server port or secret
has been modified. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3068
luxNRadiusTimeoutChangedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the radius timeout has been
changed. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3069
luxNSshEnabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the SSHD has been enabled.
The source is a 4 or 5 tuple specifying the type
location, shelf, slot ID, and optionally the port
number of the source of the event. In the case
of the power supply and fan, the shelf number is
set to 0. Each event has an unique event ID. It
also has a preset event severity. The severity
or trap type may be: critical, major, minor, or
normal. For a given event severity, there is a
corresponding system status, not necessarily the
same as the event severity. For each reported
trap, the IP address of the CP responsible for
sending this trap is also included in the trap
structure."
::= 3070
luxNSshDisabledTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the SSHD has been disabled.
The source is a 4 or 5 tuple specifying the type
location, shelf, slot ID, and optionally the port
number of the source of the event. In the case
of the power supply and fan, the shelf number is
set to 0. Each event has an unique event ID. It
also has a preset event severity. The severity
or trap type may be: critical, major, minor, or
normal. For a given event severity, there is a
corresponding system status, not necessarily the
same as the event severity. For each reported
trap, the IP address of the CP responsible for
sending this trap is also included in the trap
structure."
::= 3071
luxNSshKeySizeSetTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the SSHD key size has been
changed. The source is a 4 or 5 tuple specifying
the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3072
luxNSshMaxSessionsSetTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the telnet/SSHD max sessions
has been changed. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3073
luxNSshKeyGeneratedTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent when the SSH DSS key has finished
being generated. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 3074
luxNlogonIntruderTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that someone is
repeatly trying to logon using an invalid
password. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 4000
luxNlogonSessionStarted TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a user has
logged into the MPM. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 4001
luxNlogonSessionClosed TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that a user has
logged out of the MPM. The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 4002
luxNcpAuthenticationErrorTrap TRAP-TYPE
ENTERPRISE luxN
VARIABLES { eveDateTime, eveEventId, eveDescr, eveSeverity,
eveSysStatus, eveSource, cpIpAddress, eveSeqNum }
DESCRIPTION
"This trap is sent to indicate that an invalid
login attempt has been detected.
The source is a 4 or 5 tuple
specifying the type, location, shelf, slot ID, and
optionally the port number of the source of the
event. In the case of the power supply and fan,
the shelf number is set to 0. Each event has an
unique event ID. It also has a preset event
severity. The severity or trap type may be:
critical, major, minor, or normal. For a given
event severity, there is a corresponding system
status, not necessarily the same as the event
severity. For each reported trap, the IP address
of the CP responsible for sending this trap is
also included in the trap structure."
::= 4003