-- $Header: K:/WanSuite/archives/include/pvcs/ds8200v2.mib,v 1.40 Mar 19 2004 08:53:38 mikeh $
DS8200v2-MIB DEFINITIONS ::= BEGIN
IMPORTS enterprises,
TimeTicks,
OBJECT-TYPE,
MODULE-IDENTITY FROM SNMPv2-SMI
DisplayString FROM SNMPv2-TC
verilink,hbu FROM DS8200v2-TC-MIB;
tinterfaces MODULE-IDENTITY
LAST-UPDATED "0008180000Z"
ORGANIZATION "Verilink Corporation"
CONTACT-INFO
"support@verilink.com
+ 1 800 285 2755"
DESCRIPTION
"DS8200v2 MIB."
::= { hbu 2 }
-- { enterprises verilink hbu branch#2 (ipad is branch#1)
mgmtPorts OBJECT IDENTIFIER ::= { tinterfaces 1 }
dbu OBJECT IDENTIFIER ::= { tinterfaces 2 }
t1e1 OBJECT IDENTIFIER ::= { tinterfaces 3 }
ddsNet OBJECT IDENTIFIER ::= { tinterfaces 4 }
serialDte OBJECT IDENTIFIER ::= { tinterfaces 5 }
analogDte OBJECT IDENTIFIER ::= { tinterfaces 6 }
connection OBJECT IDENTIFIER ::= { tinterfaces 7 }
maintenance OBJECT IDENTIFIER ::= { tinterfaces 8 }
performance OBJECT IDENTIFIER ::= { tinterfaces 9 }
itable OBJECT IDENTIFIER ::= { tinterfaces 10 }
traplog OBJECT IDENTIFIER ::= { tinterfaces 11 }
unitUtilities OBJECT IDENTIFIER ::= { tinterfaces 12 }
productInfo OBJECT IDENTIFIER ::= { tinterfaces 13 }
netAPS OBJECT IDENTIFIER ::= { tinterfaces 14 }
-- productInfo section
-- brought in from old TxPort.MIB
productModelNumber OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string displays the units model number"
::= { productInfo 1 }
productModelDescr OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string displays a brief description of the unit"
::= { productInfo 2 }
productElementId OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is the same information that is in the
element id field located in the utilities Screen of
the unit's user interface. This field can be set from
either location."
::= { productInfo 3 }
productSoftwareRev OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string reports the units current software revision"
::= { productInfo 4 }
productHardwareRev OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string reports the units hardware revision"
::= { productInfo 5 }
productSerialNum OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string displays the unit's serial number"
::= { productInfo 6 }
productPhysicalAddress OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string displays the unit's physical ethernet
address"
::= { productInfo 7 }
productNmsAddress OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This string displays the unit's NMS address which
is used to identify it to the TxPORT management products"
::= { productInfo 8 }
productLabelTable OBJECT-TYPE
SYNTAX SEQUENCE OF ProductLabelTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Product Label Table."
::= { productInfo 9 }
productLabelTableEntry OBJECT-TYPE
SYNTAX ProductLabelTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the product label table."
INDEX { labelTableIndex }
::= { productLabelTable 1 }
ProductLabelTableEntry ::=
SEQUENCE
{
labelTableIndex INTEGER,
labelTableLabel DisplayString,
labelTableValue DisplayString
}
labelTableIndex OBJECT-TYPE
SYNTAX INTEGER(1..3)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The index into the ProductLabelTable."
::= { productLabelTableEntry 1 }
labelTableLabel OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A product label."
::= { productLabelTableEntry 2 }
labelTableValue OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..50))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The data associated with the label."
::= { productLabelTableEntry 3 }
-- mgmtPorts section
-- this section contains the configuration settings for the management ports
mgmtPortsTable OBJECT-TYPE
SYNTAX SEQUENCE OF MgmtPortsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Management Ports table."
::= { mgmtPorts 1 }
mgmtPortsTableEntry OBJECT-TYPE
SYNTAX MgmtPortsTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Management Ports table."
INDEX { mgmtPortsTableIndex }
::= { mgmtPortsTable 1 }
MgmtPortsTableEntry ::=
SEQUENCE
{
mgmtPortsTableIndex INTEGER,
mgmtPortsDescription DisplayString,
mgmtPortsElementID DisplayString,
mgmtPortsMode INTEGER,
mgmtPortsDialPrefix DisplayString,
mgmtPortsPrimaryDialString DisplayString,
mgmtPortsSecondaryDialString DisplayString,
mgmtPortsExtInitString DisplayString,
mgmtPortsCompressedSlip INTEGER,
mgmtPortsInternalModem INTEGER
}
mgmtPortsTableIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the Management Ports table."
::= { mgmtPortsTableEntry 1 }
mgmtPortsDescription OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..40) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains a textual description of the port."
::= { mgmtPortsTableEntry 2 }
mgmtPortsElementID OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..27) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object signifies the name of the device."
::= { mgmtPortsTableEntry 3 }
mgmtPortsMode OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
coadial(3),
coadirect(4),
extAlarmOnOpen(5),
extAlarmOnClosed(6),
slipdial(7),
slipdirect(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object signifies the method used by the port to report alarms."
::= { mgmtPortsTableEntry 4 }
mgmtPortsDialPrefix OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..38) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the dial string prefix for a modem connected to the port."
::= { mgmtPortsTableEntry 5 }
mgmtPortsPrimaryDialString OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..30) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the primary dial string for a modem connected to the port."
::= { mgmtPortsTableEntry 6 }
mgmtPortsSecondaryDialString OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..30) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the secondary dial string for a modem connected to the port."
::= { mgmtPortsTableEntry 7 }
mgmtPortsExtInitString OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..38) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object contains the init string for a modem connected to the port."
::= { mgmtPortsTableEntry 8 }
mgmtPortsCompressedSlip OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
enabled(2),
disabled(3),
auto(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if SLIP compression is to be used."
::= { mgmtPortsTableEntry 9 }
mgmtPortsInternalModem OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
notPresent(2),
enabled(3),
disabled(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object signifies if the internal modem (when present) is enabled."
::= { mgmtPortsTableEntry 10 }
-- dbu section
-- dial backup options for devices which have integrated or
-- optional dial backup units
dbuConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbuConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Dial Backup Configuration Table."
::= { dbu 1 }
dbuConfigTableEntry OBJECT-TYPE
SYNTAX DbuConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Dial Backup Configuration table."
INDEX { dbuNearIndex, dbuFarIndex, dbuConfigTableIndex }
::= { dbuConfigTable 1 }
DbuConfigTableEntry ::=
SEQUENCE
{
dbuNearIndex INTEGER,
dbuFarIndex INTEGER,
dbuConfigTableIndex INTEGER,
dbuDescription DisplayString,
dbuRate INTEGER,
dbuMode INTEGER,
dbuFormat INTEGER,
dbuNumber DisplayString,
dbuStatus INTEGER,
dbuCommand INTEGER,
dbuActivator1 INTEGER,
dbuActivator2 INTEGER,
dbuDialStr DisplayString,
dbuInitStr DisplayString,
dbuHangupStr DisplayString,
dbuPasswordStr DisplayString,
dbuSecurity INTEGER,
dbuDtrDial INTEGER,
dbuISDNSwitchType INTEGER,
dbuISDNSwitchVersion INTEGER,
dbuISDNTEI INTEGER,
dbuISDNSPID DisplayString,
dbuISDNDDNUM DisplayString
}
dbuNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { dbuConfigTableEntry 1 }
dbuFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { dbuConfigTableEntry 2 }
dbuConfigTableIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the Dial Backup table."
::= { dbuConfigTableEntry 3 }
dbuDescription OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..40) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains a textual description of the dbu."
::= { dbuConfigTableEntry 4 }
dbuRate OBJECT-TYPE
SYNTAX INTEGER
{
dbuRateOther(1),
dbuRate2400(2),
dbuRate4800(3),
dbuRate9600(4),
dbuRate19200(5),
dbuRate38400(6),
dbuRate56000(7),
dbuRate57600(8),
dbuRate64000(9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the identifier of the current DDS
DBU rate. The values mean:
dbuRate2400
the DBU interface is operating at 2400bps
dbuRate4800
the DBU interface is operating at 4800bps
dbuRate9600
the DBU interface is operating at 9600bps
dbuRate19200
the DBU interface is operating at 19200bps
dbuRate38400
the DBU interface is operating at 38400bps
dbuRate56000
the DBU interface is operating at 56000bps
dbuRate57600
the DBU interface is operating at 57600bps
dbuRate64000
the DBU interface is operating at 64000bps"
::= { dbuConfigTableEntry 5 }
dbuMode OBJECT-TYPE
SYNTAX INTEGER
{
dbuModeOther(1),
dbuModeOrig(2),
dbuModeAnsw(3),
dbuModeNotAvail(4),
dbuModeCallbackOrig(5),
dbuModeCallbackAnsw(6),
dbuModeMaster(7),
dbuModeSlave(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the identifier of the current
mode that the Dial Backup Unit is operating
in. The values mean:
dbuModeOrig
The dial backup unit is operating in the
originate mode
dbuModeAnsw
The dial backup unit is operating in the
answer mode
dbuModeNotAvail
The dial backup unit's mode is not
available
dbuModeCallbackOrig
The dial backup unit is operating in the
callback originate mode
dbuModeCallbackAnsw
The dial backup unit is operating in the
callback mode
dbuModeMaster
The dial backup unit is configured as a
master unit
dbuModeSlave
The dial backup unit is configured as a
slave unit"
::= { dbuConfigTableEntry 6 }
dbuFormat OBJECT-TYPE
SYNTAX INTEGER
{
dbuFormatOther(1),
dbuFormatSync(2),
dbuFormatAsync(3),
dbuFormatNotAvail(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the identifier of the current
format that the Dial Backup Unit is operating
in. The values mean:
dbuFormatSync
The dial backup unit is operating in the
synchronous format
dbuFormatAsync
The dial backup unit is operating in the
asynchronous format
dbuFormatNotAvail
The dial backup unit's format is
not available"
::= { dbuConfigTableEntry 7 }
dbuNumber OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..100) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is the currently programmed number
for the dial backup unit to call"
::= { dbuConfigTableEntry 8 }
dbuStatus OBJECT-TYPE
SYNTAX INTEGER
{
dbuStatusOther(1),
dbuStatusDisabled(2),
dbuStatusEnabled(3),
dbuStatusActive(4),
dbuStatusLocked(5),
dbuStatusConnecting(6),
dbuStatusDisallowed(7),
dbuStatusAwaitingCall(8),
dbuStatusDialing(9),
dbuStatusDisconnecting(10),
dbuStatusTesting(11),
dbuStatusTestPassed(12),
dbuStatusTestFailed(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the identifier of the current
Dial Backup Unit operating status.
The values mean:
dbuStatusDisabled
The dial backup unit is either not
installed or disabled
dbuStatusEnabled
The dial backup unit is installed
and enabled
dbuStatusActive
The dial backup unit is currently
active
dbuStatusLocked
The dial backup unit is in a locked
state
dbuStatusConnecting
The dial backup unit is in the process
of connecting
dbuStatusDisallowed
The dial backup unit is currently not
allowed to activate due to the Time
Of Day Enable settings
dbuStatusAwaitingCall
The dial backup unit is in the process
of waiting for an incoming call
dbuStatusDialing
The dial backup unit is in the process
of placing a call
dbuStatusDisconnecting
The dial backup unit is in the process
of disconnecting
dbuStatusTesting
The dial backup unit is in the process
of testing
dbuStatusTestPassed
The dial backup unit has passed a self-test
dbuStatusTestFailed
The dial backup unit has failed a self-test"
::= { dbuConfigTableEntry 9 }
dbuCommand OBJECT-TYPE
SYNTAX INTEGER
{
dbuCommandOther(1),
dbuCommandDisable(2),
dbuCommandEnable(3),
dbuCommandActivate(4),
dbuCommandLock(5),
dbuCommandEnableDaily(6),
dbuCommandTest(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the identifier of the current
setting that the Dial Backup Unit is operating
in. The values mean:
dbuCommandDisable
The dial backup unit is not to operate
dbuCommandEnable
The dial backup unit is to operate, subject
to Activator and line conditions only
dbuCommandActivate
The dial backup unit is to operate,
irregardless of line conditions
dbuCommandLock
The dial backup unit is to continue operating,
irregardless of line conditions
dbuCommandEnableDaily
The dial backup unit is to operate, subject
to Activator, line conditions, and the Time
Of Day Enable fields
dbuCommandTest
The dial backup unit is commanded to test
the link."
::= { dbuConfigTableEntry 10 }
dbuActivator1 OBJECT-TYPE
SYNTAX INTEGER
{
dbuActivatorOther(1),
dbuActivatorLOS(2),
dbuActivatorOOS(3),
dbuActivatorOOF(4),
dbuActivatorAny(5),
dbuActivatorES(6),
dbuActivatorSES(7),
dbuActivatorUAS(8),
dbuActivatorLOF(9),
dbuActivatorRAS(10),
dbuActivatorAIS(11),
dbuActivatorBPV(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the identifier of the current
trigger that will activate the Dial Backup
Unit. The values mean:
dbuActivatorLOS
The dial backup unit is activated by a
LOS alarm condition
dbuActivatorOOS
The dial backup unit is activated by an
OOS alarm condition
dbuActivatorOOF
The dial backup unit is activated by an
OOF alarm condition
dbuActivatorAny
The dial backup unit is activated by a
LOS, OOS, or OOF alarm condition
dbuActivatorES
The dial backup unit is activated by an
ES alarm condition
dbuActivatorSES
The dial backup unit is activated by an
SES alarm condition
dbuActivatorUAS
The dial backup unit is activated by an
UAS alarm condition
dbuActivatorLOF
The dial backup unit is activated by an
LOF alarm condition
dbuActivatorRAS
The dial backup unit is activated by an
RAS alarm condition
dbuActivatorAIS
The dial backup unit is activated by an
AIS alarm condition
dbuActivatorBPV
The dial backup unit is activated by an
BPV alarm condition"
::= { dbuConfigTableEntry 11 }
dbuActivator2 OBJECT-TYPE
SYNTAX INTEGER
{
dbuActivatorOther(1),
dbuActivatorLOS(2),
dbuActivatorOOS(3),
dbuActivatorOOF(4),
dbuActivatorAny(5),
dbuActivatorES(6),
dbuActivatorSES(7),
dbuActivatorUAS(8),
dbuActivatorLOF(9),
dbuActivatorRAS(10),
dbuActivatorAIS(11),
dbuActivatorBPV(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the identifier of the current
trigger that will activate the Dial Backup
Unit. The values mean:
dbuActivatorLOS
The dial backup unit is activated by a
LOS alarm condition
dbuActivatorOOS
The dial backup unit is activated by a
OOS alarm condition
dbuActivatorOOF
The dial backup unit is activated by a
OOF alarm condition
dbuActivatorAny
The dial backup unit is activated by a
LOS, OOS, or OOF alarm condition
dbuActivatorES
The dial backup unit is activated by an
ES alarm condition
dbuActivatorSES
The dial backup unit is activated by an
SES alarm condition
dbuActivatorUAS
The dial backup unit is activated by an
UAS alarm condition
dbuActivatorLOF
The dial backup unit is activated by an
LOF alarm condition
dbuActivatorRAS
The dial backup unit is activated by an
RAS alarm condition
dbuActivatorAIS
The dial backup unit is activated by an
AIS alarm condition
dbuActivatorBPV
The dial backup unit is activated by an
BPV alarm condition"
::= { dbuConfigTableEntry 12 }
dbuDialStr OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..50) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is the dial string sent to the dial backup unit during every connection attempt"
::= { dbuConfigTableEntry 13 }
dbuInitStr OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..50) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is the initialization string sent to the dial backup unit before every connection attempt"
::= { dbuConfigTableEntry 14 }
dbuHangupStr OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..50) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is the hangup command string sent to the dial backup unit after every successful call"
::= { dbuConfigTableEntry 15 }
dbuPasswordStr OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..8) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is the prompt character and password string for the dial backup unit in Callback DBU"
::= { dbuConfigTableEntry 16 }
dbuSecurity OBJECT-TYPE
SYNTAX INTEGER
{
dbuSecurityOther(1),
dbuSecurityDisable(2),
dbuSecurityEnable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables security on dial backup unit."
::= { dbuConfigTableEntry 17 }
dbuDtrDial OBJECT-TYPE
SYNTAX INTEGER
{
dbuDtrDialOther(1),
dbuDtrDialDisable(2),
dbuDtrDialEnable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables DTR dial feature on dial backup unit."
::= { dbuConfigTableEntry 18 }
dbuISDNSwitchType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the switch type for the ISDN DBU."
::= { dbuConfigTableEntry 19 }
dbuISDNSwitchVersion OBJECT-TYPE
SYNTAX INTEGER
{
dbuISDNSwitchVersionOther(1),
dbuISDNSwitchVersionNational1(2),
dbuISDNSwitchVersionATTP2P(3),
dbuISDNSwitchVersionATTMP(4),
dbuISDNSwitchVersionDMS100PVCIC0(5),
dbuISDNSwitchVersionDMS100PVCIC1(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the switch version for the ISDN DBU."
::= { dbuConfigTableEntry 20 }
dbuISDNTEI OBJECT-TYPE
SYNTAX INTEGER
{
dbuISDNTEIOther(1),
dbuISDNTEIDisable(2),
dbuISDNTEIAuto(3),
dbuISDNTEI0(4),
dbuISDNTEI1(5),
dbuISDNTEI2(6),
dbuISDNTEI3(7),
dbuISDNTEI4(8),
dbuISDNTEI5(9),
dbuISDNTEI6(10),
dbuISDNTEI7(11),
dbuISDNTEI8(12),
dbuISDNTEI9(13),
dbuISDNTEI10(14),
dbuISDNTEI11(15),
dbuISDNTEI12(16),
dbuISDNTEI13(17),
dbuISDNTEI14(18),
dbuISDNTEI15(19),
dbuISDNTEI16(20),
dbuISDNTEI17(21),
dbuISDNTEI18(22),
dbuISDNTEI19(23),
dbuISDNTEI20(24),
dbuISDNTEI21(25),
dbuISDNTEI22(26),
dbuISDNTEI23(27),
dbuISDNTEI24(28),
dbuISDNTEI25(29),
dbuISDNTEI26(30),
dbuISDNTEI27(31),
dbuISDNTEI28(32),
dbuISDNTEI29(33),
dbuISDNTEI30(34),
dbuISDNTEI31(35),
dbuISDNTEI32(36),
dbuISDNTEI33(37),
dbuISDNTEI34(38),
dbuISDNTEI35(39),
dbuISDNTEI36(40),
dbuISDNTEI37(41),
dbuISDNTEI38(42),
dbuISDNTEI39(43),
dbuISDNTEI40(44),
dbuISDNTEI41(45),
dbuISDNTEI42(46),
dbuISDNTEI43(47),
dbuISDNTEI44(48),
dbuISDNTEI45(49),
dbuISDNTEI46(50),
dbuISDNTEI47(51),
dbuISDNTEI48(52),
dbuISDNTEI49(53),
dbuISDNTEI50(54),
dbuISDNTEI51(55),
dbuISDNTEI52(56),
dbuISDNTEI53(57),
dbuISDNTEI54(58),
dbuISDNTEI55(59),
dbuISDNTEI56(60),
dbuISDNTEI57(61),
dbuISDNTEI58(62),
dbuISDNTEI59(63),
dbuISDNTEI60(64),
dbuISDNTEI61(65),
dbuISDNTEI62(66),
dbuISDNTEI63(67)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the ISDN DBU TEI."
::= { dbuConfigTableEntry 21 }
dbuISDNSPID OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the SPID for the ISDN DBU."
::= { dbuConfigTableEntry 22 }
dbuISDNDDNUM OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the Data Directory Number for the ISDN DBU."
::= { dbuConfigTableEntry 23 }
dbuResetStringsTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbuResetStringsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of COLD START reprogramming strings for the dial backup unit."
::= { dbu 2 }
dbuResetStringsEntry OBJECT-TYPE
SYNTAX DbuResetStringsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the dbuResetStringsTable."
INDEX { dbuResetNearIndex, dbuResetFarIndex, dbuResetConfigEntryIndex, dbuResetStringsIndex }
::= { dbuResetStringsTable 1 }
DbuResetStringsEntry ::=
SEQUENCE
{
dbuResetNearIndex INTEGER,
dbuResetFarIndex INTEGER,
dbuResetConfigEntryIndex INTEGER,
dbuResetStringsIndex INTEGER,
dbuResetString DisplayString
}
dbuResetNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { dbuResetStringsEntry 1 }
dbuResetFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { dbuResetStringsEntry 2 }
dbuResetConfigEntryIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the Dial Backup table."
::= { dbuResetStringsEntry 3 }
dbuResetStringsIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the dbuResetStringsTable."
::= { dbuResetStringsEntry 4 }
dbuResetString OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..50) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is one of the dial backup unit's COLD START reprogramming strings"
::= { dbuResetStringsEntry 5 }
dbuStartStopTable OBJECT-TYPE
SYNTAX SEQUENCE OF DbuStartStopTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Dial Backup StartStop Table."
::= { dbu 3 }
dbuStartStopTableEntry OBJECT-TYPE
SYNTAX DbuStartStopTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Dial Backup Start Stop table."
INDEX { dbuStartStopNearIndex, dbuStartStopFarIndex, dbuStartStopConfigEntryIndex, dbuStartStopDayOfWeek }
::= { dbuStartStopTable 1 }
DbuStartStopTableEntry ::=
SEQUENCE
{
dbuStartStopNearIndex INTEGER,
dbuStartStopFarIndex INTEGER,
dbuStartStopConfigEntryIndex INTEGER,
dbuStartStopDayOfWeek INTEGER,
dbuStart INTEGER,
dbuStop INTEGER
}
dbuStartStopNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { dbuStartStopTableEntry 1 }
dbuStartStopFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { dbuStartStopTableEntry 2 }
dbuStartStopConfigEntryIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the Dial Backup table."
::= { dbuStartStopTableEntry 3 }
dbuStartStopDayOfWeek OBJECT-TYPE
SYNTAX INTEGER
{
dbuStartStopSunday(1),
dbuStartStopMonday(2),
dbuStartStopTuesday(3),
dbuStartStopWednesday(4),
dbuStartStopThursday(5),
dbuStartStopFriday(6),
dbuStartStopSaturday(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the Dial Backup Start Stop times table."
::= { dbuStartStopTableEntry 4 }
dbuStart OBJECT-TYPE
SYNTAX INTEGER
{
dbuStartHour00(1),
dbuStartHour01(2),
dbuStartHour02(3),
dbuStartHour03(4),
dbuStartHour04(5),
dbuStartHour05(6),
dbuStartHour06(7),
dbuStartHour07(8),
dbuStartHour08(9),
dbuStartHour09(10),
dbuStartHour10(11),
dbuStartHour11(12),
dbuStartHour12(13),
dbuStartHour13(14),
dbuStartHour14(15),
dbuStartHour15(16),
dbuStartHour16(17),
dbuStartHour17(18),
dbuStartHour18(19),
dbuStartHour19(20),
dbuStartHour20(21),
dbuStartHour21(22),
dbuStartHour22(23),
dbuStartHour23(24)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the beginning of an allowable window for Dial Backup Activation."
::= { dbuStartStopTableEntry 5 }
dbuStop OBJECT-TYPE
SYNTAX INTEGER
{
dbuStopHour00(1),
dbuStopHour01(2),
dbuStopHour02(3),
dbuStopHour03(4),
dbuStopHour04(5),
dbuStopHour05(6),
dbuStopHour06(7),
dbuStopHour07(8),
dbuStopHour08(9),
dbuStopHour09(10),
dbuStopHour10(11),
dbuStopHour11(12),
dbuStopHour12(13),
dbuStopHour13(14),
dbuStopHour14(15),
dbuStopHour15(16),
dbuStopHour16(17),
dbuStopHour17(18),
dbuStopHour18(19),
dbuStopHour19(20),
dbuStopHour20(21),
dbuStopHour21(22),
dbuStopHour22(23),
dbuStopHour23(24)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the end of an allowable window for Dial Backup Activation."
::= { dbuStartStopTableEntry 6 }
-- t1e1 section, contains T1 and E1 Network and DTE interface table
t1e1ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1e1ConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The T1 and E1 Configuration Table."
::= { t1e1 1 }
t1e1ConfigTableEntry OBJECT-TYPE
SYNTAX T1e1ConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the t1e1Table."
INDEX { t1e1ConfigNearIndex, t1e1ConfigFarIndex, t1e1ConfigIndex }
::= { t1e1ConfigTable 1 }
T1e1ConfigTableEntry ::=
SEQUENCE
{
t1e1ConfigNearIndex INTEGER,
t1e1ConfigFarIndex INTEGER,
t1e1ConfigIndex INTEGER,
t1e1Description DisplayString,
t1e1Mode INTEGER,
t1e1FrameType INTEGER,
t1e1LineCode INTEGER,
t1e1LineBuildOut INTEGER,
t1e1Timing INTEGER,
t1e1StationInTiming INTEGER,
t1e1StationTiming INTEGER,
t1e1PRM INTEGER,
t1e1ZeroSuppress INTEGER,
t1e1NationalBit INTEGER,
t1e1KeepAlive INTEGER,
t1e1CRC4Mode INTEGER,
t1e1DSXLevel INTEGER,
t1e1CRC INTEGER,
t1e1FDLPassThrough INTEGER,
t1e1AudibleAlarm INTEGER,
t1e1Function INTEGER,
t1e1EBitGeneration INTEGER,
t1e1RAIGeneration INTEGER,
t1e1SpareBitInsertion INTEGER,
t1e1Sa4In OCTET STRING,
t1e1Sa5In OCTET STRING,
t1e1Sa6In OCTET STRING,
t1e1Sa7In OCTET STRING,
t1e1Sa8In OCTET STRING,
t1e1Sa4Out OCTET STRING,
t1e1Sa5Out OCTET STRING,
t1e1Sa6Out OCTET STRING,
t1e1Sa7Out OCTET STRING,
t1e1Sa8Out OCTET STRING
}
t1e1ConfigNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { t1e1ConfigTableEntry 1 }
t1e1ConfigFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { t1e1ConfigTableEntry 2 }
t1e1ConfigIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the index into the t1e1Table."
::= { t1e1ConfigTableEntry 3 }
t1e1Description OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..40) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains a textual description of the port."
::= { t1e1ConfigTableEntry 4 }
t1e1Mode OBJECT-TYPE
SYNTAX INTEGER
{
t1e1ModeOther(1),
t1e1ModeDTE(2),
t1e1ModeNetwork(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object identifies the port as either a Network (long-haul) or DTE (short-haul) port."
::= { t1e1ConfigTableEntry 5 }
t1e1FrameType OBJECT-TYPE
SYNTAX INTEGER
{
t1e1FrameTypeOther(1),
t1e1FrameTypeESF(2),
t1e1FrameTypeD4(3),
t1e1FrameTypeCCSCRC(4),
t1e1FrameTypeCCS(5),
t1e1FrameTypeCAS(6),
t1e1FrameTypeCASCRC(7),
t1e1FrameTypeUnframed(8),
t1e1FrameTypeV3(9),
t1e1FrameTypeT1Unframed(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the framing for the network side of the DSU/CSU."
::= { t1e1ConfigTableEntry 6 }
t1e1LineCode OBJECT-TYPE
SYNTAX INTEGER
{
t1e1LineCodeOther(1),
t1e1LineCodeAMI(2),
t1e1LineCodeB8ZS(3),
t1e1LineCodeHDB3(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the network side line coding."
::= { t1e1ConfigTableEntry 7 }
t1e1LineBuildOut OBJECT-TYPE
SYNTAX INTEGER
{
t1e1LineBuildOutOther(1),
t1e1LineBuildOut0db(2),
t1e1LineBuildOut75db(3),
t1e1LineBuildOut15db(4),
t1e1LineBuildOut225db(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the line build out for the network interface. The options are:
t1e1LineBuildOut0db indicates a line build out of 0db
t1e1LineBuildOut75db indicates a line build out of -7.5db
t1e1LineBuildOut15db indicates a line build out of -15db
t1e1LineBuildOut225db indicates a line build out of -22.5db"
::= { t1e1ConfigTableEntry 8 }
t1e1Timing OBJECT-TYPE
SYNTAX INTEGER
{
t1e1TimingOther(1),
t1e1TimingInternal(2),
t1e1TimingNetwork(3),
t1e1TimingT1DTE(4),
t1e1TimingStation(5),
t1e1TimingStaClock(6),
t1e1TimingPort1(7),
t1e1TimingPort2(8),
t1e1TimingPort3(9),
t1e1TimingPort4(10),
t1e1TimingPort5(11),
t1e1TimingPort6(12),
t1e1TimingPort7(13),
t1e1TimingPort8(14),
t1e1TimingPort9(15),
t1e1TimingPort10(16),
t1e1TimingPort11(17),
t1e1TimingPort12(18),
t1e1TimingPort13(19),
t1e1TimingPort14(20),
t1e1TimingPort15(21),
t1e1TimingPort16(22),
t1e1TimingPort17(23),
t1e1TimingPort18(24),
t1e1TimingPort19(25),
t1e1TimingPort20(26),
t1e1TimingPort21(27),
t1e1TimingPort22(28),
t1e1TimingPort23(29),
t1e1TimingPort24(30),
t1e1TimingPort25(31),
t1e1TimingPort26(32),
t1e1TimingPort27(33),
t1e1TimingPort28(34),
t1e1TimingPort29(35),
t1e1TimingPort30(36),
t1e1TimingPort31(37),
t1e1TimingPort32(38),
t1e1TimingSlot2PortA(39),
t1e1TimingSlot2PortB(40),
t1e1TimingSlot3PortA(41),
t1e1TimingSlot3PortB(42),
t1e1TimingSlot4PortA(43),
t1e1TimingSlot4PortB(44),
t1e1TimingSlot5PortA(45),
t1e1TimingSlot5PortB(46),
t1e1TimingSlot6PortA(47),
t1e1TimingSlot6PortB(48),
t1e1TimingSlot2Dsu1PortA(49),
t1e1TimingSlot2Dsu1PortB(50),
t1e1TimingSlot2Dsu2PortA(51),
t1e1TimingSlot2Dsu2PortB(52),
t1e1TimingSlot2Dsu3PortA(53),
t1e1TimingSlot2Dsu3PortB(54),
t1e1TimingSlot2Dsu4PortA(55),
t1e1TimingSlot2Dsu4PortB(56),
t1e1TimingSlot2Dsu5PortA(57),
t1e1TimingSlot2Dsu5PortB(58),
t1e1TimingSlot2Dsu6PortA(59),
t1e1TimingSlot2Dsu6PortB(60),
t1e1TimingSlot3Dsu1PortA(61),
t1e1TimingSlot3Dsu1PortB(62),
t1e1TimingSlot3Dsu2PortA(63),
t1e1TimingSlot3Dsu2PortB(64),
t1e1TimingSlot3Dsu3PortA(65),
t1e1TimingSlot3Dsu3PortB(66),
t1e1TimingSlot3Dsu4PortA(67),
t1e1TimingSlot3Dsu4PortB(68),
t1e1TimingSlot3Dsu5PortA(69),
t1e1TimingSlot3Dsu5PortB(70),
t1e1TimingSlot3Dsu6PortA(71),
t1e1TimingSlot3Dsu6PortB(72),
t1e1TimingSlot4Dsu1PortA(73),
t1e1TimingSlot4Dsu1PortB(74),
t1e1TimingSlot4Dsu2PortA(75),
t1e1TimingSlot4Dsu2PortB(76),
t1e1TimingSlot4Dsu3PortA(77),
t1e1TimingSlot4Dsu3PortB(78),
t1e1TimingSlot4Dsu4PortA(79),
t1e1TimingSlot4Dsu4PortB(80),
t1e1TimingSlot4Dsu5PortA(81),
t1e1TimingSlot4Dsu5PortB(82),
t1e1TimingSlot4Dsu6PortA(83),
t1e1TimingSlot4Dsu6PortB(84),
t1e1TimingSlot5Dsu1PortA(85),
t1e1TimingSlot5Dsu1PortB(86),
t1e1TimingSlot5Dsu2PortA(87),
t1e1TimingSlot5Dsu2PortB(88),
t1e1TimingSlot5Dsu3PortA(89),
t1e1TimingSlot5Dsu3PortB(90),
t1e1TimingSlot5Dsu4PortA(91),
t1e1TimingSlot5Dsu4PortB(92),
t1e1TimingSlot5Dsu5PortA(93),
t1e1TimingSlot5Dsu5PortB(94),
t1e1TimingSlot5Dsu6PortA(95),
t1e1TimingSlot5Dsu6PortB(96),
t1e1TimingSlot6Dsu1PortA(97),
t1e1TimingSlot6Dsu1PortB(98),
t1e1TimingSlot6Dsu2PortA(99),
t1e1TimingSlot6Dsu2PortB(100),
t1e1TimingSlot6Dsu3PortA(101),
t1e1TimingSlot6Dsu3PortB(102),
t1e1TimingSlot6Dsu4PortA(103),
t1e1TimingSlot6Dsu4PortB(104),
t1e1TimingSlot6Dsu5PortA(105),
t1e1TimingSlot6Dsu5PortB(106),
t1e1TimingSlot6Dsu6PortA(107),
t1e1TimingSlot6Dsu6PortB(108)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the timing source to synchronize the unit's internal timing generators."
::= { t1e1ConfigTableEntry 9 }
t1e1StationInTiming OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StationInTimingOther(1),
t1e1StationInTimingNX56(2),
t1e1StationInTimingNX64(3),
t1e1StationInTiming1544(4),
t1e1StationInTiming2048(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the input timing if t1e1Timing is set to Station."
::= { t1e1ConfigTableEntry 10 }
t1e1StationTiming OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the N-multiple when Station Input Timing is set to either NX56 or NX65. The N range is 1..24"
::= { t1e1ConfigTableEntry 11 }
t1e1PRM OBJECT-TYPE
SYNTAX INTEGER
{
t1e1PRMOther(1),
t1e1PRMDisable(2),
t1e1PRMEnable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the ANSI T1.403 Performance Report Message functions."
::= { t1e1ConfigTableEntry 12 }
t1e1ZeroSuppress OBJECT-TYPE
SYNTAX INTEGER
{
t1e1ZeroOther(1),
t1e1ZeroDisable(2),
t1e1ZeroEnable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines whether ones density insertion is activated after 15 zeros . To ensure compliance with TR54016, this field must be enabled."
::= { t1e1ConfigTableEntry 13 }
t1e1NationalBit OBJECT-TYPE
SYNTAX INTEGER
{
t1e1NationalOther(1),
t1e1NationalNone(2),
t1e1NationalSA4(3),
t1e1NationalSA5(4),
t1e1NationalSA6(5),
t1e1NationalSA7(6),
t1e1NationalSA8(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects a national bit to create a 4-kbps datalink between the endpoint units."
::= { t1e1ConfigTableEntry 14 }
t1e1KeepAlive OBJECT-TYPE
SYNTAX INTEGER
{
t1e1KeepAliveOther(1),
t1e1KeepAliveUnframedOnes(2),
t1e1KeepAliveFramedOnes(3),
t1e1KeepAliveLoop(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects keep alive framed and unframed ones when the unit detects LOS or OOF."
::= { t1e1ConfigTableEntry 15 }
t1e1CRC4Mode OBJECT-TYPE
SYNTAX INTEGER
{
t1e1CRC4Other(1),
t1e1CRC4Disabled(2),
t1e1CRC4Enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects whether CRC4 is enabled or disabled."
::= { t1e1ConfigTableEntry 16 }
t1e1DSXLevel OBJECT-TYPE
SYNTAX INTEGER
{
t1e1DSXOther(1),
t1e1DSX0110(2),
t1e1DSX111220(3),
t1e1DSX221330(4),
t1e1DSX331440(5),
t1e1DSX441550(6),
t1e1DSX551660(7),
t1e1DSX661up(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the DSX1 interface output level."
::= { t1e1ConfigTableEntry 17 }
t1e1CRC OBJECT-TYPE
SYNTAX INTEGER
{
t1e1CRCOther(1),
t1e1CRCPass(2),
t1e1CRCRegenerate(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines whether received CRC data is passed through or regenerated."
::= { t1e1ConfigTableEntry 18 }
t1e1FDLPassThrough OBJECT-TYPE
SYNTAX INTEGER
{
t1e1FDLPassThroughOther(1),
t1e1FDLPassThroughPass(2),
t1e1FDLPassThroughTerminate(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines whether the ESF FDL passes through the CSU or terminates."
::= { t1e1ConfigTableEntry 19 }
t1e1AudibleAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1AudibleAlarmOther(1),
t1e1AudibleAlarmDisabled(2),
t1e1AudibleAlarmEnabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If applicable, Enables or Disables the CSU's internal buzzer which alerts users of an alarm condition."
::= { t1e1ConfigTableEntry 20 }
t1e1Function OBJECT-TYPE
SYNTAX INTEGER
{
t1e1FunctionOther(1),
t1e1FunctionNetwork(2),
t1e1FunctionSlaved(3),
t1e1FunctionBackup(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the function the network port will perform in the unit.
The options are:
t1e1FunctionNetwork (Independent network port)
t1e1FunctionSlaved (Slaved to another network port)
t1e1FunctionBackup (Automatic Protection Switching Backup for another network port)"
::= { t1e1ConfigTableEntry 21 }
t1e1EBitGeneration OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 22 }
t1e1RAIGeneration OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 23 }
t1e1SpareBitInsertion OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 24 }
t1e1Sa4In OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 25 }
t1e1Sa5In OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 26 }
t1e1Sa6In OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 27 }
t1e1Sa7In OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 28 }
t1e1Sa8In OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 29 }
t1e1Sa4Out OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 30 }
t1e1Sa5Out OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 31 }
t1e1Sa6Out OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 32 }
t1e1Sa7Out OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 33 }
t1e1Sa8Out OBJECT-TYPE
SYNTAX OCTET STRING( SIZE(8) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { t1e1ConfigTableEntry 34 }
t1e1AlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF T1e1AlarmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The T1 and E1 Alarm Table."
::= { t1e1 2 }
t1e1AlarmTableEntry OBJECT-TYPE
SYNTAX T1e1AlarmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the t1e1Table."
INDEX { t1e1AlarmNearIndex, t1e1AlarmFarIndex, t1e1AlarmIndex }
::= { t1e1AlarmTable 1 }
T1e1AlarmTableEntry ::=
SEQUENCE
{
t1e1AlarmNearIndex INTEGER,
t1e1AlarmFarIndex INTEGER,
t1e1AlarmIndex INTEGER,
t1e1StatusSummary DisplayString,
t1e1AlarmSummary DisplayString,
t1e1ESStatus INTEGER,
t1e1ESCount INTEGER,
t1e1ESThreshold INTEGER,
t1e1ESAlarm INTEGER,
t1e1SESStatus INTEGER,
t1e1SESCount INTEGER,
t1e1SESThreshold INTEGER,
t1e1SESAlarm INTEGER,
t1e1LOSSStatus INTEGER,
t1e1LOSSCount INTEGER,
t1e1LOSSThreshold INTEGER,
t1e1LOSSAlarm INTEGER,
t1e1UASStatus INTEGER,
t1e1UASCount INTEGER,
t1e1UASThreshold INTEGER,
t1e1UASAlarm INTEGER,
t1e1CSSStatus INTEGER,
t1e1CSSCount INTEGER,
t1e1CSSThreshold INTEGER,
t1e1CSSAlarm INTEGER,
t1e1BPVSStatus INTEGER,
t1e1BPVSCount INTEGER,
t1e1BPVSThreshold INTEGER,
t1e1BPVSAlarm INTEGER,
t1e1OOFSStatus INTEGER,
t1e1OOFSCount INTEGER,
t1e1OOFSThreshold INTEGER,
t1e1OOFSAlarm INTEGER,
t1e1AISStatus INTEGER,
t1e1AISCount INTEGER,
t1e1AISThreshold INTEGER,
t1e1AISAlarm INTEGER,
t1e1RASStatus INTEGER,
t1e1RASCount INTEGER,
t1e1RASThreshold INTEGER,
t1e1RASAlarm INTEGER,
t1e1AlarmResetTimer INTEGER,
t1e1AlarmReset INTEGER
}
t1e1AlarmNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { t1e1AlarmTableEntry 1 }
t1e1AlarmFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { t1e1AlarmTableEntry 2 }
t1e1AlarmIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is the index into the t1e1Table."
::= { t1e1AlarmTableEntry 3 }
t1e1StatusSummary OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a summary of the port status."
::= { t1e1AlarmTableEntry 4 }
t1e1AlarmSummary OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a summary of the port alarms."
::= { t1e1AlarmTableEntry 5 }
t1e1ESStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StatusOther(1),
t1e1StatusNoES(2),
t1e1StatusES(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if an Errored Second condition exists."
::= { t1e1AlarmTableEntry 6 }
t1e1ESCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds an Errored Second condition has existed."
::= { t1e1AlarmTableEntry 7 }
t1e1ESThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the Errored Seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 8 }
t1e1ESAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1ESAlarmOther(1),
t1e1ESAlarmNone(2),
t1e1ESAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Errors Seconds threshold is exceeded."
::= { t1e1AlarmTableEntry 9 }
t1e1SESStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StatusOther(1),
t1e1StatusNoSES(2),
t1e1StatusSES(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if a Severely Errored condition exists."
::= { t1e1AlarmTableEntry 10 }
t1e1SESCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds a Severely Errored condition has existed."
::= { t1e1AlarmTableEntry 11 }
t1e1SESThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the Severely Errored seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 12 }
t1e1SESAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1SESAlarmOther(1),
t1e1SESAlarmNone(2),
t1e1SESAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Severely Errors Seconds threshold is exceeded."
::= { t1e1AlarmTableEntry 13 }
t1e1LOSSStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StatusOther(1),
t1e1StatusNoLOSS(2),
t1e1StatusLOSS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if a Loss of Signal condition exists."
::= { t1e1AlarmTableEntry 14 }
t1e1LOSSCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds a Loss of Signal condition has existed."
::= { t1e1AlarmTableEntry 15 }
t1e1LOSSThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the Loss of Signal seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 16 }
t1e1LOSSAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1LOSSAlarmOther(1),
t1e1LOSSAlarmNone(2),
t1e1LOSSAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Loss of Signal Seconds threshold is exceeded."
::= { t1e1AlarmTableEntry 17 }
t1e1UASStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StatusOther(1),
t1e1StatusNoUAS(2),
t1e1StatusUAS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if an Unavailable condition exists."
::= { t1e1AlarmTableEntry 18 }
t1e1UASCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds an Unavailable condition has existed."
::= { t1e1AlarmTableEntry 19 }
t1e1UASThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the unavailable seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 20 }
t1e1UASAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1UASAlarmOther(1),
t1e1UASAlarmNone(2),
t1e1UASAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Unavailable Seconds threshold is exceeded."
::= { t1e1AlarmTableEntry 21 }
t1e1CSSStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StatusOther(1),
t1e1StatusNoCSS(2),
t1e1StatusCSS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if a Controlled Slip condition exists."
::= { t1e1AlarmTableEntry 22 }
t1e1CSSCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds in which at least one Controlled Slip occurred."
::= { t1e1AlarmTableEntry 23 }
t1e1CSSThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the Controlled Slip seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 24 }
t1e1CSSAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1CSSAlarmOther(1),
t1e1CSSAlarmNone(2),
t1e1CSSAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Controlled Slip seconds threshold is exceeded."
::= { t1e1AlarmTableEntry 25 }
t1e1BPVSStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StatusOther(1),
t1e1StatusNoBPVS(2),
t1e1StatusBPVS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if a Bipolar Violation Error condition exists."
::= { t1e1AlarmTableEntry 26 }
t1e1BPVSCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds a Bipolar Violation Error condition has existed."
::= { t1e1AlarmTableEntry 27 }
t1e1BPVSThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the Bipolar Violation Error seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 28 }
t1e1BPVSAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1BPVSAlarmOther(1),
t1e1BPVSAlarmNone(2),
t1e1BPVSAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Bipolar Violation Error seconds threshold is exceeded."
::= { t1e1AlarmTableEntry 29 }
t1e1OOFSStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StatusOther(1),
t1e1StatusNoOOF(2),
t1e1StatusOOF(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates that the unit is unable to synchronize on the incoming framing pattern."
::= { t1e1AlarmTableEntry 30 }
t1e1OOFSCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds an OOF condition has existed."
::= { t1e1AlarmTableEntry 31 }
t1e1OOFSThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the OOF seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 32 }
t1e1OOFSAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1OOFSAlarmOther(1),
t1e1OOFSAlarmNone(2),
t1e1OOFSAlarmExists(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if an OOF seconds alarm condition exists."
::= { t1e1AlarmTableEntry 33 }
t1e1AISStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1StatusOther(1),
t1e1StatusNoAIS(2),
t1e1StatusAIS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates that the unit is receiving an unframed all ones pattern."
::= { t1e1AlarmTableEntry 34 }
t1e1AISCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds an Unframed All Ones condition has existed."
::= { t1e1AlarmTableEntry 35 }
t1e1AISThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the AIS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 36 }
t1e1AISAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1AISAlarmOther(1),
t1e1AISAlarmNone(2),
t1e1AISAlarmExists(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates if an Unframed All Ones alarm condition exists."
::= { t1e1AlarmTableEntry 37 }
t1e1RASStatus OBJECT-TYPE
SYNTAX INTEGER
{
t1e1RASStatusOther(1),
t1e1RASStatusNoRAS(2),
t1e1RASStatusRAS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if a Remote (Yellow) Alarm condition exists."
::= { t1e1AlarmTableEntry 38 }
t1e1RASCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds a Remote (Yellow) Alarm condition has existed."
::= { t1e1AlarmTableEntry 39 }
t1e1RASThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the RAS seconds alarm threshold. Setting this field to 0 disables the alarm. The threshold can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 40 }
t1e1RASAlarm OBJECT-TYPE
SYNTAX INTEGER
{
t1e1RASAlarmOther(1),
t1e1RASAlarmNone(2),
t1e1RASAlarmExists(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if a Remote (Yellow) Alarm exists."
::= { t1e1AlarmTableEntry 41 }
t1e1AlarmResetTimer OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900."
::= { t1e1AlarmTableEntry 42 }
t1e1AlarmReset OBJECT-TYPE
SYNTAX INTEGER
{
t1e1AlarmResetOther(1),
t1e1AlarmResetClearAlarms(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to clear the current alarm counts."
::= { t1e1AlarmTableEntry 43 }
-- ddsNet section, contains DDS Network interface table
ddsNetConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF DdsNetConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The dds Network Interface Configuration Table."
::= { ddsNet 1 }
ddsNetConfigTableEntry OBJECT-TYPE
SYNTAX DdsNetConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Network Interface Table."
INDEX { ddsNetConfigNearIndex, ddsNetConfigFarIndex, ddsNetConfigIndex }
::= { ddsNetConfigTable 1 }
DdsNetConfigTableEntry ::=
SEQUENCE
{
ddsNetConfigNearIndex INTEGER,
ddsNetConfigFarIndex INTEGER,
ddsNetConfigIndex INTEGER,
ddsNetDescription DisplayString,
ddsNetRate INTEGER,
ddsNetMode INTEGER,
ddsNetTimingSource INTEGER,
ddsNetRemComm INTEGER,
ddsNetCircuitAssur INTEGER,
ddsNetAntiStrTimer INTEGER
}
ddsNetConfigNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { ddsNetConfigTableEntry 1 }
ddsNetConfigFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { ddsNetConfigTableEntry 2 }
ddsNetConfigIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the ddsNetConfigTable."
::= { ddsNetConfigTableEntry 3 }
ddsNetDescription OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..40) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Contains a textual description of the port."
::= { ddsNetConfigTableEntry 4 }
ddsNetRate OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetRate2400(1),
ddsNetRate4800(2),
ddsNetRate9600(3),
ddsNetRate19200(4),
ddsNetRate38400(5),
ddsNetRate56000(6),
ddsNetRate64000(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the identifier of the current DDS network rate. The values mean:
ddsNetRate2400
the DDS network interface is operating at
2400bps
ddsNetRate4800
the DDS network interface is operating at
4800bps
ddsNetRate9600
the DDS network interface is operating at
9600bps
ddsNetRate19200
the DDS network interface is operating at
19200bps
ddsNetRate38400
the DDS network interface is operating at
38400bps
ddsNetRate56000
the DDS network interface is operating at
56000bps
ddsNetRate64000
the DDS network interface is operating at
64000bps"
::= { ddsNetConfigTableEntry 5 }
ddsNetMode OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetModeNormal(1),
ddsNetModeProprietaryTXPI(2),
ddsNetMode64KClearChannel(3),
ddsNetMode64KCCProprietaryTXPII(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes mode in which data is
being sent from the DDS unit back towards the
network. Changing the value of this variable can
cause a loss of remote communications.
The values mean:
ddsNetModeNormal (DDS-I)
normal data mode of operation
ddsNetModeProprietaryTXPI (DDS-I)
data being sent out on the DDS network is
in a proprietary mode to allow for remote
communications, rate adaption, and SYNC to
ASYNC modes
ddsNetMode64KClearChannel (DDS-II)
A special case of DDS-II, where the line rate is 72K,
the data rate is 64K, and there is no secondary channel.
ddsNetMode64KCCProprietaryTXPII (DDS-II)
A special case of DDS-II, where the line rate is 72K,
the data rate is 64K, and there is no secondary channel.
In addition, the data being sent out on the DDS network
is in a proprietary mode to allow for remote communications,
rate adaption, SYNC to ASYNC, and/or TDM modes."
::= { ddsNetConfigTableEntry 6 }
ddsNetTimingSource OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetTimingNet(1),
ddsNetTimingInt(2),
ddsNetTimingDTE(3),
ddsNetTimingPort1(4),
ddsNetTimingPort2(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the current timing source for
the DDS network interface. The values mean:
ddsNetTimingNet
unit dependant upon network for DDS network
interface timing
ddsNetTimingInt
unit supplying timing for DDS network
interface
ddsNetTimingDTE
unit dependant upon DTE device for network
interface timing
ddsNetTimingPort1
unit dependant upon serial port 1 device for network
interface timing
ddsNetTimingPort2
unit dependant upon serial port 2 device for network
interface timing"
::= { ddsNetConfigTableEntry 7 }
ddsNetRemComm OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetRemCommEnabled(1),
ddsNetRemCommDisabled(2),
ddsNetRemCommNotAvailable(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable describes the current setting for the
remote communications link. The values mean:
ddsNetRemCommEnabled
remote communications can be carried out end
to end
ddsNetRemCommDisabled
remote communications are not allowed
ddsNetRemCommNotAvailable
this unit does not support remote
communications"
::= { ddsNetConfigTableEntry 8 }
ddsNetCircuitAssur OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetCircuitAssurEnabled(1),
ddsNetCircuitAssurDisabled(2),
ddsNetCircuitAssurNotAvailable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the current setting for the
circuit assurance option. The values mean:
ddsNetCircuitAssurEnabled
Circuit Assurance is enabled and the
integrity of the DDS loop will be maintained
ddsNetCircuitAssurDisabled
Circuit Assurance is disabled
ddsNetCircuitAssurNotAvailable
this unit does not support Circuit Assurance"
::= { ddsNetConfigTableEntry 9 }
ddsNetAntiStrTimer OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetAntiStrTimerOff(1),
ddsNetAntiStrTimer10(2),
ddsNetAntiStrTimer30(3),
ddsNetAntiStrTimer60(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the current setting for the
anti streaming timer. The values mean:
ddsNetAntiStrTimerOff
the AntiStreaming Timer is off
ddsNetAntiStrTimer10
the AntiStreaming Timer is set to 10 seconds
ddsNetAntiStrTimer30
the AntiStreaming Timer is set to 30 seconds
ddsNetAntiStrTimer60
the AntiStreaming Timer is set to 60 seconds"
::= { ddsNetConfigTableEntry 10 }
ddsNetAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DdsNetAlarmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The dds Network Interface Alarm Table."
::= { ddsNet 2 }
ddsNetAlarmTableEntry OBJECT-TYPE
SYNTAX DdsNetAlarmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ddsNetAlarmTable."
INDEX { ddsNetAlarmNearIndex, ddsNetAlarmFarIndex, ddsNetAlarmIndex }
::= { ddsNetAlarmTable 1 }
DdsNetAlarmTableEntry ::=
SEQUENCE
{
ddsNetAlarmNearIndex INTEGER,
ddsNetAlarmFarIndex INTEGER,
ddsNetAlarmIndex INTEGER,
ddsNetStatusSummary DisplayString,
ddsNetAlarmSummary DisplayString,
ddsNetLOSStatus INTEGER,
ddsNetLOSCount INTEGER,
ddsNetLOSThreshold INTEGER,
ddsNetLOSAlarm INTEGER,
ddsNetOOFStatus INTEGER,
ddsNetOOFCount INTEGER,
ddsNetOOFThreshold INTEGER,
ddsNetOOFAlarm INTEGER,
ddsNetOOSStatus INTEGER,
ddsNetOOSCount INTEGER,
ddsNetOOSThreshold INTEGER,
ddsNetOOSAlarm INTEGER,
ddsNetFDLStatus INTEGER,
ddsNetFDLCount INTEGER,
ddsNetFDLThreshold INTEGER,
ddsNetFDLAlarm INTEGER,
ddsNetAlarmResetTimer INTEGER,
ddsNetAlarmReset INTEGER,
ddsNetBPVStatus INTEGER,
ddsNetBPVCount INTEGER,
ddsNetBPVThreshold INTEGER,
ddsNetBPVAlarm INTEGER
}
ddsNetAlarmNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { ddsNetAlarmTableEntry 1 }
ddsNetAlarmFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { ddsNetAlarmTableEntry 2 }
ddsNetAlarmIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the ddsNetAlarmTable."
::= { ddsNetAlarmTableEntry 3 }
ddsNetStatusSummary OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a summary of the port status."
::= { ddsNetAlarmTableEntry 4 }
ddsNetAlarmSummary OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a summary of the port alarms."
::= { ddsNetAlarmTableEntry 5 }
ddsNetLOSStatus OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetStatusLOSOther(1),
ddsNetStatusNoLOS(2),
ddsNetStatusLOS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if a Loss of Signal condition exists."
::= { ddsNetAlarmTableEntry 6 }
ddsNetLOSCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds the unit received signal has been interrupted."
::= { ddsNetAlarmTableEntry 7 }
ddsNetLOSThreshold OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetLOSThresholdOther(1),
ddsNetLOSThresholdNone(2),
ddsNetLOSThreshold1(3),
ddsNetLOSThreshold2(4),
ddsNetLOSThreshold3(5),
ddsNetLOSThreshold4(6),
ddsNetLOSThreshold5(7),
ddsNetLOSThreshold10(8),
ddsNetLOSThreshold20(9),
ddsNetLOSThreshold30(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A period, measured in seconds, in which the DDS received signal is interrupted."
::= { ddsNetAlarmTableEntry 8 }
ddsNetLOSAlarm OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetLOSAlarmOther(1),
ddsNetLOSAlarmNone(2),
ddsNetLOSAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Loss of Signal Seconds threshold is exceeded."
::= { ddsNetAlarmTableEntry 9 }
ddsNetOOFStatus OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetStatusOOFOther(1),
ddsNetStatusNoOOF(2),
ddsNetStatusOOF(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if an Out of Frame condition exists."
::= { ddsNetAlarmTableEntry 10 }
ddsNetOOFCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds the unit has received the out of frame code."
::= { ddsNetAlarmTableEntry 11 }
ddsNetOOFThreshold OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetOOFThresholdOther(1),
ddsNetOOFThresholdNone(2),
ddsNetOOFThreshold1(3),
ddsNetOOFThreshold2(4),
ddsNetOOFThreshold3(5),
ddsNetOOFThreshold4(6),
ddsNetOOFThreshold5(7),
ddsNetOOFThreshold10(8),
ddsNetOOFThreshold20(9),
ddsNetOOFThreshold30(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A period, measured in seconds, in which the Out Of Frame code is received or a frame sync loss occurred."
::= { ddsNetAlarmTableEntry 12 }
ddsNetOOFAlarm OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetOOFSAlarmOther(1),
ddsNetOOFSAlarmNone(2),
ddsNetOOFSAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Out of Frame Seconds threshold is exceeded."
::= { ddsNetAlarmTableEntry 13 }
ddsNetOOSStatus OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetStatusOOSOther(1),
ddsNetStatusNoOOS(2),
ddsNetStatusOOS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if Out of Service codes are received."
::= { ddsNetAlarmTableEntry 14 }
ddsNetOOSCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds the unit has received the out of service code."
::= { ddsNetAlarmTableEntry 15 }
ddsNetOOSThreshold OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetOOSThresholdOther(1),
ddsNetOOSThresholdNone(2),
ddsNetOOSThreshold1(3),
ddsNetOOSThreshold2(4),
ddsNetOOSThreshold3(5),
ddsNetOOSThreshold4(6),
ddsNetOOSThreshold5(7),
ddsNetOOSThreshold10(8),
ddsNetOOSThreshold20(9),
ddsNetOOSThreshold30(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A period, measured in seconds, in which the Out Of Service code is received."
::= { ddsNetAlarmTableEntry 16 }
ddsNetOOSAlarm OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetOOSAlarmOther(1),
ddsNetOOSAlarmNone(2),
ddsNetOOSAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Out of Service Seconds threshold is exceeded."
::= { ddsNetAlarmTableEntry 17 }
ddsNetFDLStatus OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetStatusFDLOther(1),
ddsNetStatusNoFDL(2),
ddsNetStatusFDL(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if Facility Data Link errors have occurred."
::= { ddsNetAlarmTableEntry 18 }
ddsNetFDLCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds in which FDL errors have occurred."
::= { ddsNetAlarmTableEntry 19 }
ddsNetFDLThreshold OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetFDLThresholdOther(1),
ddsNetFDLThresholdNone(2),
ddsNetFDLThreshold1(3),
ddsNetFDLThreshold2(4),
ddsNetFDLThreshold3(5),
ddsNetFDLThreshold4(6),
ddsNetFDLThreshold5(7),
ddsNetFDLThreshold10(8),
ddsNetFDLThreshold20(9),
ddsNetFDLThreshold30(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A period, measured in seconds, in which FDL errors have occurred."
::= { ddsNetAlarmTableEntry 20 }
ddsNetFDLAlarm OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetFDLAlarmOther(1),
ddsNetFDLAlarmNone(2),
ddsNetFDLAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Facility Data Link threshold is exceeded."
::= { ddsNetAlarmTableEntry 21 }
ddsNetAlarmResetTimer OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the Alarm Reset Timer, this field can be set to any value in the range 0 to 900."
::= { ddsNetAlarmTableEntry 22 }
ddsNetAlarmReset OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetAlarmResetOther(1),
ddsNetAlarmResetClearAlarms(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is used to clear the current alarm counts."
::= { ddsNetAlarmTableEntry 23 }
ddsNetBPVStatus OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetStatusBPVOther(1),
ddsNetStatusNoBPV(2),
ddsNetStatusBPV(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if a Bipolar violation event occurred in the last second."
::= { ddsNetAlarmTableEntry 24 }
ddsNetBPVCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of consecutive seconds the unit received bipolar violations."
::= { ddsNetAlarmTableEntry 25 }
ddsNetBPVThreshold OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetBPVThresholdOther(1),
ddsNetBPVThresholdNone(2),
ddsNetBPVThreshold1(3),
ddsNetBPVThreshold2(4),
ddsNetBPVThreshold3(5),
ddsNetBPVThreshold4(6),
ddsNetBPVThreshold5(7),
ddsNetBPVThreshold10(8),
ddsNetBPVThreshold20(9),
ddsNetBPVThreshold30(10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A period, measured in seconds, in which the unit receives bipolar violations
before an alarm is triggered."
::= { ddsNetAlarmTableEntry 26 }
ddsNetBPVAlarm OBJECT-TYPE
SYNTAX INTEGER
{
ddsNetBPVAlarmOther(1),
ddsNetBPVAlarmNone(2),
ddsNetBPVAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the Bipolar violation Seconds threshold is exceeded."
::= { ddsNetAlarmTableEntry 27 }
-- serialDte section
serialDteConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialDteConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Serial DTE Config Table."
::= { serialDte 1 }
serialDteConfigTableEntry OBJECT-TYPE
SYNTAX SerialDteConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the serial DTE Config Table."
INDEX { serialDteConfigNearIndex, serialDteConfigFarIndex, serialDteConfigIndex }
::= { serialDteConfigTable 1 }
SerialDteConfigTableEntry ::=
SEQUENCE
{
serialDteConfigNearIndex INTEGER,
serialDteConfigFarIndex INTEGER,
serialDteConfigIndex INTEGER,
serialDteDescription DisplayString,
serialDteType INTEGER,
serialDteRate INTEGER,
serialDteInvertData INTEGER,
serialDteFormat INTEGER,
serialDteParity INTEGER,
serialDteStopBit INTEGER,
serialDteMode INTEGER,
serialDteDSR INTEGER,
serialDteDCD INTEGER,
serialDteRTS INTEGER,
serialDteRTSDelay INTEGER,
serialDteDTR INTEGER,
serialDteCTS INTEGER,
serialDteV54 INTEGER,
serialDteLL INTEGER,
serialDteRL INTEGER,
serialDteStartChannel INTEGER,
serialDteNumberOfChannels INTEGER,
serialDteTxClock INTEGER,
serialDteBundle INTEGER,
serialDteChannelRate INTEGER,
serialDteInvertClock INTEGER,
serialDteCharSize INTEGER,
serialDteFlowControl INTEGER,
serialDtePinStatus DisplayString,
serialDteInInvertClock INTEGER
}
serialDteConfigNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { serialDteConfigTableEntry 1 }
serialDteConfigFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { serialDteConfigTableEntry 2 }
serialDteConfigIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the DteTable."
::= { serialDteConfigTableEntry 3 }
serialDteDescription OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..40) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains a textual description of the port."
::= { serialDteConfigTableEntry 4 }
serialDteType OBJECT-TYPE
SYNTAX INTEGER
{
serialDteTypeOther(1),
serialDteTypeV35(2),
serialDteTypeRS232(3),
serialDteTypeEIA530(4),
serialDteTypeX21(5),
serialDteTypeV36(6),
serialDteTypeEIA530A(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the DTE port type if applicable."
::= { serialDteConfigTableEntry 5 }
serialDteRate OBJECT-TYPE
SYNTAX INTEGER
{
serialDteRateOther(1),
serialDteRate2400(2),
serialDteRate4800(3),
serialDteRate9600(4),
serialDteRate19200(5),
serialDteRate38400(6),
serialDteRate52000(7),
serialDteRate56000(8),
serialDteRate57600(9),
serialDteRate60000(10),
serialDteRate64000(11),
serialDteRate112000(12),
serialDteRate128000(13),
serialDteRate168000(14),
serialDteRate192000(15),
serialDteRate224000(16),
serialDteRate256000(17),
serialDteRate280000(18),
serialDteRate320000(19),
serialDteRate336000(20),
serialDteRate384000(21),
serialDteRate392000(22),
serialDteRate448000(23),
serialDteRate504000(24),
serialDteRate512000(25),
serialDteRate560000(26),
serialDteRate576000(27),
serialDteRate616000(28),
serialDteRate640000(29),
serialDteRate672000(30),
serialDteRate704000(31),
serialDteRate728000(32),
serialDteRate768000(33),
serialDteRate784000(34),
serialDteRate832000(35),
serialDteRate840000(36),
serialDteRate896000(37),
serialDteRate952000(38),
serialDteRate960000(39),
serialDteRate1008000(40),
serialDteRate1024000(41),
serialDteRate1064000(42),
serialDteRate1088000(43),
serialDteRate1120000(44),
serialDteRate1152000(45),
serialDteRate1176000(46),
serialDteRate1216000(47),
serialDteRate1232000(48),
serialDteRate1280000(49),
serialDteRate1288000(50),
serialDteRate1344000(51),
serialDteRate1400000(52),
serialDteRate1408000(53),
serialDteRate1456000(54),
serialDteRate1472000(55),
serialDteRate1512000(56),
serialDteRate1536000(57),
serialDteRate1568000(58),
serialDteRate1600000(59),
serialDteRate1624000(60),
serialDteRate1664000(61),
serialDteRate1680000(62),
serialDteRate1728000(63),
serialDteRate1736000(64),
serialDteRate1792000(65),
serialDteRate1856000(66),
serialDteRate1920000(67),
serialDteRate1984000(68),
serialDteRate2048000(69),
serialDteRate1200(70),
serialDteRate14400(71),
serialDteRate28800(72),
serialDteRate48000(73),
serialDteRate31200(74),
serialDteRate115200(75),
serialDteRate2112000(76),
serialDteRate2176000(77),
serialDteRate2240000(78),
serialDteRate2304000(79),
serialDteRate300(80),
serialDteRate600(81),
serialDteRate3072000(82),
serialDteRate4096000(83)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the DTE port bit."
::= { serialDteConfigTableEntry 6 }
serialDteInvertData OBJECT-TYPE
SYNTAX INTEGER
{
serialDteInvertDataOther(1),
serialDteInvertDataDisabled(2),
serialDteInvertDataEnabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies whether transmit and receive are inverted at the port."
::= { serialDteConfigTableEntry 7 }
serialDteFormat OBJECT-TYPE
SYNTAX INTEGER
{
serialDteFormatOther(1),
serialDteFormatSync(2),
serialDteFormatAsync(3),
serialDteFormatNotAvail(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the current operations format
of the DTE interface. The values mean:
serialDteFormatSync
The DTE interface is currently set to operate
in Synchronous clocking format
serialDteFormatAsync
The DTE interface is currently set to operate
in the Asynchronous clocking format
serialDteFormatNotAvail
The DTE interface operating format is not
available"
::= { serialDteConfigTableEntry 8 }
-- The DTE Parity is only valid when the DTE Mode is set to ASYNC
serialDteParity OBJECT-TYPE
SYNTAX INTEGER
{
serialDteParityOther(1),
serialDteParityNone(2),
serialDteParityOdd(3),
serialDteParityEven(4),
serialDteParityMark(5),
serialDteParitySpace(6),
serialDteParityNotAvail(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the current parity selected
for the DTE interface. This variable is only valid
when the DTE Mode is set to ASYNC. The values mean:
serialDteParityNone
The DTE interface is currently set for
no parity bit checking or generation
serialDteParityOdd
The DTE interface is currently set
for odd parity
serialDteParityEven
The DTE interface is currently set
for even parity
serialDteParityMark
The DTE interface is currently set
for mark parity
serialDteParitySpace
The DTE interface is currently set
for space parity
serialDteParityNotAvail
The parity setting on the DTE interface is not
available."
::= { serialDteConfigTableEntry 9 }
-- The Stop bit setting is only valid when the DTE interface is set to
-- ASYNC operation.
serialDteStopBit OBJECT-TYPE
SYNTAX INTEGER
{
serialDteStopBitOther(1),
serialDteStopBit1(2),
serialDteStopBit2(3),
serialDteStopBitNotAvail(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the stop bit setting for the
DTE interface. This variable is only valid when the
DTE interface is set to ASYNC. The values mean:
serialDteStopBit1
The DTE interface is configured to operate in
the ASYNC mode with 1 stop bit
serialDteStopBit2
The DTE interface is configured to operate in
the ASYNC mode with 2 stop bits
serialDteStopBitNotAvail
The stop bit information is not available. The
DTE interface is probably configured for
synchronous operation."
::= { serialDteConfigTableEntry 10 }
serialDteMode OBJECT-TYPE
SYNTAX INTEGER
{
serialDteModeOther(1),
serialDteModeDDSI(2),
serialDteModeDDSII(3),
serialDteModeTxpINormal(4),
serialDteModeTxpITDM(5),
serialDteModeTxpIINormal(6),
serialDteModeTxpIITDM(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes mode in which data is
being sent from the DDS unit back towards the network. "
::= { serialDteConfigTableEntry 11 }
serialDteDSR OBJECT-TYPE
SYNTAX INTEGER
{
serialDteDSROther(1),
serialDteDSRTestOff(2),
serialDteDSRForcedOn(3),
serialDteDSRForcedOff(4),
serialDteDSRInternal(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects DSR behavior."
::= { serialDteConfigTableEntry 12 }
serialDteDCD OBJECT-TYPE
SYNTAX INTEGER
{
serialDteDCDOther(1),
serialDteDCDIdleOff(2),
serialDteDCDForcedOn(3),
serialDteDCDForcedOff(4),
serialDteDCDInternal(5),
serialDteDCDFarRTS(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects DCD behavior."
::= { serialDteConfigTableEntry 13 }
serialDteRTS OBJECT-TYPE
SYNTAX INTEGER
{
serialDteRTSOther(1),
serialDteRTSNormal(2),
serialDteRTSForcedOn(3),
serialDteRTSExternal(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects RTS behavior."
::= { serialDteConfigTableEntry 14 }
serialDteRTSDelay OBJECT-TYPE
SYNTAX INTEGER
{
serialDteRTSDelayOther(1),
serialDteRTSDelayNormal(2),
serialDteRTSDelayLong(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects RTS to CTS transition delay."
::= { serialDteConfigTableEntry 15 }
serialDteDTR OBJECT-TYPE
SYNTAX INTEGER
{
serialDteDTROther(1),
serialDteDTRFalse(2),
serialDteDTRTrue(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if DTR from the DTE device is false."
::= { serialDteConfigTableEntry 16 }
serialDteCTS OBJECT-TYPE
SYNTAX INTEGER
{
serialDteCTSOther(1),
serialDteCTSForceTrue(2),
serialDteCTSForceFalse(3),
serialDteCTSInternal(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the control of the CTS signal at the port."
::= { serialDteConfigTableEntry 17 }
serialDteV54 OBJECT-TYPE
SYNTAX INTEGER
{
serialDteV54Other(1),
serialDteV54Disable(2),
serialDteV54Enable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies if the unit should respond to inband V.54 loop commands."
::= { serialDteConfigTableEntry 18 }
serialDteLL OBJECT-TYPE
SYNTAX INTEGER
{
serialDteLLOther(1),
serialDteLLDisable(2),
serialDteLLEnable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies if the unit should respond to local loop activation by the local loopback signal (EIA530 or RS-232 pin 18)."
::= { serialDteConfigTableEntry 19 }
serialDteRL OBJECT-TYPE
SYNTAX INTEGER
{
serialDteRLOther(1),
serialDteRLDisable(2),
serialDteRLEnable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies if the unit should respond to remote loop activation by the remote loopback signal (EIA530 or RS-232 pin 21)."
::= { serialDteConfigTableEntry 20 }
serialDteStartChannel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the starting channel for the interface."
::= { serialDteConfigTableEntry 21 }
serialDteNumberOfChannels OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of channels allocated to the interface."
::= { serialDteConfigTableEntry 22 }
serialDteTxClock OBJECT-TYPE
SYNTAX INTEGER
{
serialDteTxClockOther(1),
serialDteTxClockInternal(2),
serialDteTxClockExternal(3),
serialDteTxClockOversample(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies how the interface derives its transmit clock."
::= { serialDteConfigTableEntry 23 }
serialDteBundle OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
contiguous(2),
alternate(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the allocation pattern of channels assigned
to the serial port."
::= { serialDteConfigTableEntry 24 }
serialDteChannelRate OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
nx56k(2),
nx64k(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the rate of all channels assigned to the serial port."
::= { serialDteConfigTableEntry 25 }
serialDteInvertClock OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies if an inverted clock is used to send data from the serial port."
::= { serialDteConfigTableEntry 26 }
serialDteCharSize OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
five(2),
six(3),
seven(4),
eight(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the number of bits per character. This variable is
valid in ASYNC mode."
::= {serialDteConfigTableEntry 27 }
serialDteFlowControl OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
none(2),
xonXoff(3),
rtsCts(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the Flow control to use. This variable is
valid only in ASYNC mode."
::= { serialDteConfigTableEntry 28 }
serialDtePinStatus OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a summary of the Serial port pin status."
::= { serialDteConfigTableEntry 29 }
serialDteInInvertClock OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies to use the inverted clock edge for data clocked into the serial port."
::= { serialDteConfigTableEntry 30 }
-- Dte Alarm Table
serialDteAlarmTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialDteAlarmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Serial DTE Alarm Table."
::= { serialDte 2 }
serialDteAlarmTableEntry OBJECT-TYPE
SYNTAX SerialDteAlarmTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the serial DTE Alarm Table."
INDEX { serialDteAlarmNearIndex, serialDteAlarmFarIndex, serialDteAlarmIndex }
::= { serialDteAlarmTable 1 }
SerialDteAlarmTableEntry ::=
SEQUENCE
{
serialDteAlarmNearIndex INTEGER,
serialDteAlarmFarIndex INTEGER,
serialDteAlarmIndex INTEGER,
serialDteDTRAlarmControl INTEGER,
serialDteDTRAlarmStatus INTEGER,
serialDteStatusSummary DisplayString,
serialDteAlarmSummary DisplayString,
serialDteASCStatus INTEGER,
serialDteASCCount INTEGER,
serialDteASCThreshold INTEGER,
serialDteASCAlarm INTEGER,
serialDteFDLStatus INTEGER,
serialDteFDLCount INTEGER,
serialDteFDLThreshold INTEGER,
serialDteFDLAlarm INTEGER,
serialDteLOSStatus INTEGER,
serialDteLOSCount INTEGER,
serialDteLOSThreshold INTEGER,
serialDteLOSAlarm INTEGER
}
serialDteAlarmNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { serialDteAlarmTableEntry 1 }
serialDteAlarmFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { serialDteAlarmTableEntry 2 }
serialDteAlarmIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the serialDteAlarmTable."
::= { serialDteAlarmTableEntry 3 }
serialDteDTRAlarmControl OBJECT-TYPE
SYNTAX INTEGER
{
serialDteDTRAlarmOther(1),
serialDteDTRAlarmDisable(2),
serialDteDTRAlarmEnable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies if the unit should alarm on loss of DTR."
::= { serialDteAlarmTableEntry 4 }
serialDteDTRAlarmStatus OBJECT-TYPE
SYNTAX INTEGER
{
serialDteDTRAlarmOther(1),
serialDteDTRAlarmNone(2),
serialDteDTRAlarmActive(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates a DTR Loss alarm is active."
::= { serialDteAlarmTableEntry 5 }
serialDteStatusSummary OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a summary of the port status."
::= { serialDteAlarmTableEntry 6 }
serialDteAlarmSummary OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object provides a summary of the port alarms."
::= { serialDteAlarmTableEntry 7 }
serialDteASCStatus OBJECT-TYPE
SYNTAX INTEGER
{
serialDteStatusASCOther(1),
serialDteStatusNoASC(2),
serialDteStatusASC(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if an ASC condition exists on the interface."
::= { serialDteAlarmTableEntry 8 }
serialDteASCCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of ASC seconds received by the interface."
::= { serialDteAlarmTableEntry 9 }
serialDteASCThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of ASC seconds that must be received before an alarm is declared."
::= { serialDteAlarmTableEntry 10 }
serialDteASCAlarm OBJECT-TYPE
SYNTAX INTEGER
{
serialDteASCAlarmOther(1),
serialDteASCAlarmNone(2),
serialDteASCAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the ASC Seconds threshold is exceeded."
::= { serialDteAlarmTableEntry 11 }
serialDteFDLStatus OBJECT-TYPE
SYNTAX INTEGER
{
serialDteStatusFDLOther(1),
serialDteStatusNoFDL(2),
serialDteStatusFDL(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if an FDL error condition exists on the interface."
::= { serialDteAlarmTableEntry 12 }
serialDteFDLCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of FDL errored seconds received by the interface."
::= { serialDteAlarmTableEntry 13 }
serialDteFDLThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of FDL errored seconds that must be received before an alarm is declared."
::= { serialDteAlarmTableEntry 14 }
serialDteFDLAlarm OBJECT-TYPE
SYNTAX INTEGER
{
serialDteFDLAlarmOther(1),
serialDteFDLAlarmNone(2),
serialDteFDLAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the FDL Errored Seconds threshold is exceeded."
::= { serialDteAlarmTableEntry 15 }
serialDteLOSStatus OBJECT-TYPE
SYNTAX INTEGER
{
serialDteStatusLOSOther(1),
serialDteStatusNoLOS(2),
serialDteStatusLOS(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports if an LOS condition exists on the interface."
::= { serialDteAlarmTableEntry 16 }
serialDteLOSCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This count contains the number of LOS seconds received by the interface."
::= { serialDteAlarmTableEntry 17 }
serialDteLOSThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of LOS seconds that must be received before an alarm is declared."
::= { serialDteAlarmTableEntry 18 }
serialDteLOSAlarm OBJECT-TYPE
SYNTAX INTEGER
{
serialDteLOSAlarmOther(1),
serialDteLOSAlarmNone(2),
serialDteLOSAlarmThresholdExceeded(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if the LOS Seconds threshold is exceeded."
::= { serialDteAlarmTableEntry 19 }
-- analog DTE section
analogDteTable OBJECT-TYPE
SYNTAX SEQUENCE OF AnalogDteTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Analog DTE Table."
::= { analogDte 1 }
analogDteTableEntry OBJECT-TYPE
SYNTAX AnalogDteTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Analog DTE Table."
INDEX { analogDteNearIndex, analogDteFarIndex, analogDteIndex }
::= { analogDteTable 1 }
AnalogDteTableEntry ::=
SEQUENCE
{
analogDteNearIndex INTEGER,
analogDteFarIndex INTEGER,
analogDteIndex INTEGER,
analogDteDescription DisplayString,
analogDteCardType INTEGER,
analogDteMode INTEGER,
analogDteState INTEGER,
analogDteElementID DisplayString,
analogDteSignalling INTEGER,
analogDteDNISDelay INTEGER,
analogDteTxGain INTEGER,
analogDteRxGain INTEGER
}
analogDteNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { analogDteTableEntry 1 }
analogDteFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { analogDteTableEntry 2 }
analogDteIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index into the analogDteTable."
::= { analogDteTableEntry 3 }
analogDteDescription OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..40) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains a textual description of the port."
::= { analogDteTableEntry 4 }
analogDteCardType OBJECT-TYPE
SYNTAX INTEGER
{
analogDteCardTypeOther(1),
analogDteCardTypeFXS(2),
analogDteCardTypeFXO(3),
analogDteCardType4WEM(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies the analog DTE card type."
::= { analogDteTableEntry 5 }
analogDteMode OBJECT-TYPE
SYNTAX INTEGER
{
analogDteModeOther(1),
analogDteModeSpare(2),
analogDteModeActive(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects whether the port is actively assigned to a network channel or not used."
::= { analogDteTableEntry 6 }
analogDteState OBJECT-TYPE
SYNTAX INTEGER
{
analogDteStateOther(1),
analogDteStateIdle(2),
analogDteStateBusy(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the port status as either in the Busy or Idle state."
::= { analogDteTableEntry 7 }
analogDteElementID OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..20) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object signifies the name of the device."
::= { analogDteTableEntry 8 }
analogDteSignalling OBJECT-TYPE
SYNTAX INTEGER
{
analogDteSignallingOther(1),
analogDteSignallingFXSLS(2),
analogDteSignallingFXSGS(3),
analogDteSignallingUVG(4),
analogDteSignallingMEGLS(5),
analogDteSignallingMEGGS(6),
analogDteSignallingMEGRLS(7),
analogDteSignallingMEGRGS(8),
analogDteSignallingPLAR(9),
analogDteSignallingSLC96(10),
analogDteSignallingDIDDNIS(11),
analogDteSignallingDNISWLS(12),
analogDteSignallingDNISDLS(13),
analogDteSignallingDNISWRLS(14),
analogDteSignallingDNISDRLS(15),
analogDteSignallingDNISWGS(16),
analogDteSignallingDNISDGS(17),
analogDteSignallingDNISWRGS(18),
analogDteSignallingDNISDRGS(19),
analogDteSignallingFXOLS(20),
analogDteSignallingFXOGS(21),
analogDteSignallingFXOUVG(22),
analogDteSignallingFXOUVGR(23),
analogDteSignalling4WEMTYPE1(24),
analogDteSignalling4WEMTYPE2(25),
analogDteSignalling4WEMTYPE3(26),
analogDteSignalling4WEMTYPE4(27),
analogDteSignalling4WEMTYPE5(28),
analogDteSignalling4WEMTO(29)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the supervisory operation of the port."
::= { analogDteTableEntry 9 }
analogDteDNISDelay OBJECT-TYPE
SYNTAX INTEGER
{
analogDteDNISDelayOther(1),
analogDteDNISDelay1Second(2),
analogDteDNISDelay2Seconds(3),
analogDteDNISDelay3Seconds(4),
analogDteDNISDelay4Seconds(5),
analogDteDNISDelay5Seconds(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If the signalling mode has a delay, it can be set from 1 to 5 seconds."
::= { analogDteTableEntry 10 }
analogDteTxGain OBJECT-TYPE
SYNTAX INTEGER
{
analogDteTxGainOther(1),
analogDteTxGain3DB(2),
analogDteTxGain2DB(3),
analogDteTxGain1DB(4),
analogDteTxGain0DB(5),
analogDteTxGainm1DB(6),
analogDteTxGainm2DB(7),
analogDteTxGainm3DB(8),
analogDteTxGainm4DB(9),
analogDteTxGainm5DB(10),
analogDteTxGainm6DB(11),
analogDteTxGainm7DB(12),
analogDteTxGainm8DB(13),
analogDteTxGainm9DB(14),
analogDteTxGainm10DB(15)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the transmit gain. Values prefixed with m are negative."
::= { analogDteTableEntry 11 }
analogDteRxGain OBJECT-TYPE
SYNTAX INTEGER
{
analogDteRxGainOther(1),
analogDteRxGain2DB(2),
analogDteRxGain1DB(3),
analogDteRxGain0DB(4),
analogDteRxGainm1DB(5),
analogDteRxGainm2DB(6),
analogDteRxGainm3DB(7),
analogDteRxGainm4DB(8),
analogDteRxGainm5DB(9),
analogDteRxGainm6DB(10),
analogDteRxGainm7DB(11),
analogDteRxGainm8DB(12),
analogDteRxGainm9DB(13),
analogDteRxGainm10DB(14),
analogDteRxGainm11DB(15),
analogDteRxGainm12DB(16),
analogDteRxGainm13DB(17),
analogDteRxGainm14DB(18),
analogDteRxGainm15DB(19),
analogDteRxGainm16DB(20)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the receive gain. Values prefixed with m are negative."
::= { analogDteTableEntry 12 }
-- connection table
-- allows for configuration/connection of dte ports to network ports
connectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnectionTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The connection table."
::= { connection 1 }
connectionTableEntry OBJECT-TYPE
SYNTAX ConnectionTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the connection table."
INDEX { connectionNearIndex, connectionFarIndex, connectionTableIndex }
::= { connectionTable 1 }
ConnectionTableEntry ::=
SEQUENCE
{
connectionNearIndex INTEGER,
connectionFarIndex INTEGER,
connectionTableIndex INTEGER,
connectionTableDescription DisplayString
}
connectionNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { connectionTableEntry 1 }
connectionFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { connectionTableEntry 2 }
connectionTableIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the connection table."
::= { connectionTableEntry 3 }
connectionTableDescription OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..60))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the connection."
::= { connectionTableEntry 4 }
connectionChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConnectionChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The channel-level connection table."
::= { connection 2 }
connectionChannelEntry OBJECT-TYPE
SYNTAX ConnectionChannelEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the connectionChannelTable."
INDEX { connectionChannelNearIndex, connectionChannelFarIndex, connectionChannelLineIndex, connectionChannelIndex }
::= { connectionChannelTable 1 }
ConnectionChannelEntry ::=
SEQUENCE
{
connectionChannelNearIndex INTEGER,
connectionChannelFarIndex INTEGER,
connectionChannelLineIndex INTEGER,
connectionChannelIndex INTEGER,
channelInterfaceAssignment INTEGER,
channelInterfaceDescription DisplayString,
channelInterfaceChannel INTEGER,
channelSignalling INTEGER
}
connectionChannelNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { connectionChannelEntry 1 }
connectionChannelFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { connectionChannelEntry 2 }
connectionChannelLineIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects instance of line."
::= { connectionChannelEntry 3 }
connectionChannelIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the connection table."
::= { connectionChannelEntry 4 }
channelInterfaceAssignment OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
unassigned(2),
dTE(3),
remComm(4),
port1(5),
port2(6),
port3(7),
port4(8),
port5(9),
port6(10),
port7(11),
port8(12),
port9(13),
port10(14),
port11(15),
port12(16),
port13(17),
port14(18),
port15(19),
port16(20),
port17(21),
port18(22),
port19(23),
port20(24),
port21(25),
port22(26),
port23(27),
port24(28),
port25(29),
port26(30),
port27(31),
port28(32),
port29(33),
port30(34),
port31(35),
port32(36),
slot2PortA(37),
slot2PortB(38),
slot3PortA(39),
slot3PortB(40),
slot4PortA(41),
slot4PortB(42),
slot5PortA(43),
slot5PortB(44),
slot6PortA(45),
slot6PortB(46),
slot2Dsu1PortA(47),
slot2Dsu1PortB(48),
slot2Dsu2PortA(49),
slot2Dsu2PortB(50),
slot2Dsu3PortA(51),
slot2Dsu3PortB(52),
slot2Dsu4PortA(53),
slot2Dsu4PortB(54),
slot2Dsu5PortA(55),
slot2Dsu5PortB(56),
slot2Dsu6PortA(57),
slot2Dsu6PortB(58),
slot3Dsu1PortA(59),
slot3Dsu1PortB(60),
slot3Dsu2PortA(61),
slot3Dsu2PortB(62),
slot3Dsu3PortA(63),
slot3Dsu3PortB(64),
slot3Dsu4PortA(65),
slot3Dsu4PortB(66),
slot3Dsu5PortA(67),
slot3Dsu5PortB(68),
slot3Dsu6PortA(69),
slot3Dsu6PortB(70),
slot4Dsu1PortA(71),
slot4Dsu1PortB(72),
slot4Dsu2PortA(73),
slot4Dsu2PortB(74),
slot4Dsu3PortA(75),
slot4Dsu3PortB(76),
slot4Dsu4PortA(77),
slot4Dsu4PortB(78),
slot4Dsu5PortA(79),
slot4Dsu5PortB(80),
slot4Dsu6PortA(81),
slot4Dsu6PortB(82),
slot5Dsu1PortA(83),
slot5Dsu1PortB(84),
slot5Dsu2PortA(85),
slot5Dsu2PortB(86),
slot5Dsu3PortA(87),
slot5Dsu3PortB(88),
slot5Dsu4PortA(89),
slot5Dsu4PortB(90),
slot5Dsu5PortA(91),
slot5Dsu5PortB(92),
slot5Dsu6PortA(93),
slot5Dsu6PortB(94),
slot6Dsu1PortA(95),
slot6Dsu1PortB(96),
slot6Dsu2PortA(97),
slot6Dsu2PortB(98),
slot6Dsu3PortA(99),
slot6Dsu3PortB(100),
slot6Dsu4PortA(101),
slot6Dsu4PortB(102),
slot6Dsu5PortA(103),
slot6Dsu5PortB(104),
slot6Dsu6PortA(105),
slot6Dsu6PortB(106)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The channel assignment."
::= { connectionChannelEntry 5 }
channelInterfaceDescription OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains a description of the interface channel connection."
::= { connectionChannelEntry 6 }
channelInterfaceChannel OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Displays the corresponding channel of the interface channel connection."
::= { connectionChannelEntry 7 }
channelSignalling OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
clearChannel(2),
robbedBit(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Allows a selection of Clear Channel or Robbed Bit signalling for each DS0."
::= { connectionChannelEntry 8 }
-- maintenance section
-- controls tests
--
-- BERT Table
--
bertTable OBJECT-TYPE
SYNTAX SEQUENCE OF BertTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BERT control table."
::= { maintenance 1 }
bertTableEntry OBJECT-TYPE
SYNTAX BertTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the BERT control table."
INDEX { bertNearIndex, bertFarIndex, bertIndex }
::= { bertTable 1 }
BertTableEntry ::=
SEQUENCE
{
bertNearIndex INTEGER,
bertFarIndex INTEGER,
bertIndex INTEGER,
bertPattern INTEGER,
bertLength INTEGER,
bertPatternSync INTEGER,
bertElapsedTime INTEGER,
bertBitErrors INTEGER,
bertErroredSeconds INTEGER,
bertPercentEFS INTEGER,
bertCommand INTEGER
}
bertNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { bertTableEntry 1 }
bertFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { bertTableEntry 2 }
bertIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the BERT control table. Selects which BERT chip to use."
::= { bertTableEntry 3 }
bertPattern OBJECT-TYPE
SYNTAX INTEGER
{
bertPatternOther(1),
bertPatternQRSS(2),
bertPattern63(3),
bertPattern511(4),
bertPattern2047(5),
bertPattern215(6),
bertPattern220(7),
bertPattern223(8),
bertPattern1in8(9),
bertPattern3in24(10),
bertPatternALT(11),
bertPatternCLEAR(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the test pattern to be used."
::= { bertTableEntry 4 }
bertLength OBJECT-TYPE
SYNTAX INTEGER
{
bertLengthOther(1),
bertLength15minutes(2),
bertLength30minutes(3),
bertLength60minutes(4),
bertLength24hours(5),
bertLengthContinuous(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies how long the test should run."
::= { bertTableEntry 5 }
bertPatternSync OBJECT-TYPE
SYNTAX INTEGER
{
bertPatternSyncOther(1),
bertPatternSyncNoTest(2),
bertPatternSyncNoSync(3),
bertPatternSyncInsync(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the current state of pattern sync during a test."
::= { bertTableEntry 6 }
bertElapsedTime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the amount of time elapsed since a timed test began in seconds."
::= { bertTableEntry 7 }
bertBitErrors OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the total number of bit errors detected since the test began."
::= { bertTableEntry 8 }
bertErroredSeconds OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays the number of asynchronous errored seconds that have been detected since the test began."
::= { bertTableEntry 9 }
bertPercentEFS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Displays a ratio derived from the number of error free seconds divided by the number of seconds accumulated in elapsed time."
::= { bertTableEntry 10 }
bertCommand OBJECT-TYPE
SYNTAX INTEGER
{
bertCommandOther(1),
bertCommandStart(2),
bertCommandStop(3),
bertCommandResetErrors(4),
bertCommandInjectError(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Issues a test command for the interface."
::= { bertTableEntry 11 }
bertInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF BertInterfaceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"BERT control interface table."
::= { maintenance 2 }
bertInterfaceTableEntry OBJECT-TYPE
SYNTAX BertInterfaceTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the BERT control interface table."
INDEX { bertInterfaceNearIndex, bertInterfaceFarIndex, bertChipIndex, bertInterfaceIndex }
::= { bertInterfaceTable 1 }
BertInterfaceTableEntry ::=
SEQUENCE
{
bertInterfaceNearIndex INTEGER,
bertInterfaceFarIndex INTEGER,
bertChipIndex INTEGER,
bertInterfaceIndex INTEGER,
bertInterfaceSetting INTEGER,
bertInterfaceService INTEGER,
bertInterfaceChannelRate INTEGER
}
bertInterfaceNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { bertInterfaceTableEntry 1 }
bertInterfaceFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { bertInterfaceTableEntry 2 }
bertChipIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects which BERT chip to use."
::= { bertInterfaceTableEntry 3 }
bertInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index into the MIB-II interfaces table; the interface for the BERT settings."
::= { bertInterfaceTableEntry 4 }
bertInterfaceSetting OBJECT-TYPE
SYNTAX INTEGER
{
bertInterfaceSettingOther(1),
bertInterfaceSettingIdle(2),
bertInterfaceSettingChannel1(3),
bertInterfaceSettingChannel2(4),
bertInterfaceSettingChannel3(5),
bertInterfaceSettingChannel4(6),
bertInterfaceSettingChannel5(7),
bertInterfaceSettingChannel6(8),
bertInterfaceSettingChannel7(9),
bertInterfaceSettingChannel8(10),
bertInterfaceSettingChannel9(11),
bertInterfaceSettingChannel10(12),
bertInterfaceSettingChannel11(13),
bertInterfaceSettingChannel12(14),
bertInterfaceSettingChannel13(15),
bertInterfaceSettingChannel14(16),
bertInterfaceSettingChannel15(17),
bertInterfaceSettingChannel16(18),
bertInterfaceSettingChannel17(19),
bertInterfaceSettingChannel18(20),
bertInterfaceSettingChannel19(21),
bertInterfaceSettingChannel20(22),
bertInterfaceSettingChannel21(23),
bertInterfaceSettingChannel22(24),
bertInterfaceSettingChannel23(25),
bertInterfaceSettingChannel24(26),
bertInterfaceSettingChannel25(27),
bertInterfaceSettingChannel26(28),
bertInterfaceSettingChannel27(29),
bertInterfaceSettingChannel28(30),
bertInterfaceSettingChannel29(31),
bertInterfaceSettingChannel30(32),
bertInterfaceSettingChannel31(33),
bertInterfaceSettingChannel32(34),
bertInterfaceSettingNet(35),
bertInterfaceSettingDTE(36),
bertInterfaceSettingNotEnabled(37),
bertInterfaceSettingUseService(38)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies where to send the BERT pattern."
::= { bertInterfaceTableEntry 5 }
bertInterfaceService OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the service (see ipadv2.mib) to BERT. The bandwidth associated with
the service will get the BERT pattern."
::= { bertInterfaceTableEntry 6 }
bertInterfaceChannelRate OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
nx56k(2),
nx64k(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the network channel rate for all channels involved
in a network BERT."
::= { bertInterfaceTableEntry 7 }
--
-- Test Table
--
testTable OBJECT-TYPE
SYNTAX SEQUENCE OF TestTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Test control table."
::= { maintenance 3 }
testTableEntry OBJECT-TYPE
SYNTAX TestTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the testTable."
INDEX { testNearIndex, testFarIndex, testTableIndex }
::= { testTable 1 }
TestTableEntry ::=
SEQUENCE
{
testNearIndex INTEGER,
testFarIndex INTEGER,
testTableIndex INTEGER,
testType INTEGER,
testLoopDirection INTEGER,
testFarLLBFraming INTEGER,
testLoopInitiator INTEGER,
testDefaultLoopType INTEGER
}
testNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { testTableEntry 1 }
testFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { testTableEntry 2 }
testTableIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the testTable, one entry for each interface."
::= { testTableEntry 3 }
testType OBJECT-TYPE
SYNTAX INTEGER
{
testTypeOther(1),
testTypeNoTest(2),
testTypePLB(3),
testTypeLLB(4),
testtypeMLB(5),
testTypeFarPLB(6),
testTypeFarLLB(7),
testTypeFarMLB(8),
testTypePortLoop(9),
testTypeV54Loop(10),
testTypeFarV54Loop(11),
testTypeFarPortLoop(12),
testTypeTDM(13),
testTypeFarPortUnloop(14),
testTypeFarV54Unloop(15),
testTypeDualLoop(16),
testTypeNetworkSideTransparent(17),
testTypeNetworkSideNonTransparent(18),
testTypeCustomerSideTransparent(19),
testTypeCustomerSideNonTransparent(20)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Identifies the test type for the interface."
::= { testTableEntry 4 }
testLoopDirection OBJECT-TYPE
SYNTAX INTEGER
{
testLoopOther(1),
testLoopUnidirectional(2),
testLoopBidirectional(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is the identifier of the current unit loop mode. The values mean:
testLoopUnidirectional
Line, Data, and V54 loops will be unidirectional
Local loop will be bidirectional
testLoopBidirectional
All loops will be bidirectional"
::= { testTableEntry 5 }
testFarLLBFraming OBJECT-TYPE
SYNTAX INTEGER
{
testFarLLBFramingOther(1),
testFarLLBFramingUnframed(2),
testFarLLBFramingFramed(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This setting, for Far LLB tests on T1 lines, must match the far end unit loop code framing."
::= { testTableEntry 6 }
testLoopInitiator OBJECT-TYPE
SYNTAX INTEGER
{
testLoopInitiatorOther(1),
testLoopInitiatorLMP(2),
testLoopInitiatorSNMP(3),
testLoopInitiatorWeb(4),
testLoopInitiatorEOC(5),
testLoopInitiatorButtons(6),
testLoopInitiatorDCEControl(7),
testLoopInitiatorISDNPRAV3(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates who started the loop."
::= { testTableEntry 7 }
testDefaultLoopType OBJECT-TYPE
SYNTAX INTEGER
{
testDefaultLoopTypeOther(1),
testDefaultLoopTypeTransparent(2),
testDefaultLoopTypeNonTransparent(3),
testDefaultLoopTypeDual(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Identifies the default loop type."
::= { testTableEntry 8 }
-- performance section
-- performance section
performance24Table OBJECT-TYPE
SYNTAX SEQUENCE OF Performance24TableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance table, contains TR54016 standard and enhanced data."
::= { performance 1 }
performance24TableEntry OBJECT-TYPE
SYNTAX Performance24TableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the performance24Table."
INDEX { performance24NearIndex, performance24FarIndex, performance24InterfaceIndex, performance24Index }
::= { performance24Table 1 }
Performance24TableEntry ::=
SEQUENCE
{
performance24NearIndex INTEGER,
performance24FarIndex INTEGER,
performance24InterfaceIndex INTEGER,
performance24Index INTEGER,
performance24ES INTEGER,
performance24BES INTEGER,
performance24SES INTEGER,
performance24UAS INTEGER,
performance24LOFC INTEGER,
performance24CSS INTEGER,
performance24CRCES INTEGER,
performance24OOFS INTEGER,
performance24LOSS INTEGER,
performance24AISS INTEGER,
performance24RAS INTEGER,
performance24BPVS INTEGER,
performance24timestamp TimeTicks
}
performance24NearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { performance24TableEntry 1 }
performance24FarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { performance24TableEntry 2 }
performance24InterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the interface."
::= { performance24TableEntry 3 }
performance24Index OBJECT-TYPE
SYNTAX INTEGER
{
performance24Summary(1),
performance24Current(2),
performance24period1(3),
performance24period2(4),
performance24period3(5),
performance24period4(6),
performance24period5(7),
performance24period6(8),
performance24period7(9),
performance24period8(10),
performance24period9(11),
performance24period10(12),
performance24period11(13),
performance24period12(14),
performance24period13(15),
performance24period14(16),
performance24period15(17),
performance24period16(18),
performance24period17(19),
performance24period18(20),
performance24period19(21),
performance24period20(22),
performance24period21(23),
performance24period22(24),
performance24period23(25),
performance24period24(26),
performance24period25(27),
performance24period26(28),
performance24period27(29),
performance24period28(30),
performance24period29(31),
performance24period30(32),
performance24period31(33),
performance24period32(34),
performance24period33(35),
performance24period34(36),
performance24period35(37),
performance24period36(38),
performance24period37(39),
performance24period38(40),
performance24period39(41),
performance24period40(42),
performance24period41(43),
performance24period42(44),
performance24period43(45),
performance24period44(46),
performance24period45(47),
performance24period46(48),
performance24period47(49),
performance24period48(50),
performance24period49(51),
performance24period50(52),
performance24period51(53),
performance24period52(54),
performance24period53(55),
performance24period54(56),
performance24period55(57),
performance24period56(58),
performance24period57(59),
performance24period58(60),
performance24period59(61),
performance24period60(62),
performance24period61(63),
performance24period62(64),
performance24period63(65),
performance24period64(66),
performance24period65(67),
performance24period66(68),
performance24period67(69),
performance24period68(70),
performance24period69(71),
performance24period70(72),
performance24period71(73),
performance24period72(74),
performance24period73(75),
performance24period74(76),
performance24period75(77),
performance24period76(78),
performance24period77(79),
performance24period78(80),
performance24period79(81),
performance24period80(82),
performance24period81(83),
performance24period82(84),
performance24period83(85),
performance24period84(86),
performance24period85(87),
performance24period86(88),
performance24period87(89),
performance24period88(90),
performance24period89(91),
performance24period90(92),
performance24period91(93),
performance24period92(94),
performance24period93(95),
performance24period94(96),
performance24period95(97),
performance24period96(98)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the 24-hour performance table."
::= { performance24TableEntry 4 }
performance24ES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds for the 15-minute period."
::= { performance24TableEntry 5 }
performance24BES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Bursty Errored Seconds for the 15-minute period."
::= { performance24TableEntry 6 }
performance24SES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Seconds for the 15-minute period."
::= { performance24TableEntry 7 }
performance24UAS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds for the 15-minute period."
::= { performance24TableEntry 8 }
performance24LOFC OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Loss of Frame Counts for the 15-minute period."
::= { performance24TableEntry 9 }
performance24CSS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Controlled Slip Seconds for the 15-minute period."
::= { performance24TableEntry 10 }
performance24CRCES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of CRC Errored Seconds for the 15-minute period."
::= { performance24TableEntry 11 }
performance24OOFS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Out of Frame Seconds for the 15-minute period."
::= { performance24TableEntry 12 }
performance24LOSS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Loss of Signal Seconds for the 15-minute period."
::= { performance24TableEntry 13 }
performance24AISS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Alarm Indication Signal Seconds for the 15-minute period."
::= { performance24TableEntry 14 }
performance24RAS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Remote Alarm (Yellow) Seconds for the 15-minute period."
::= { performance24TableEntry 15 }
performance24BPVS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Bipolar Violation Seconds for the 15-minute period."
::= { performance24TableEntry 16 }
performance24timestamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the statistics were last updated."
::= { performance24TableEntry 17 }
performance30Table OBJECT-TYPE
SYNTAX SEQUENCE OF Performance30TableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance table, contains TR54016 standard and enhanced 30-day data."
::= { performance 2 }
performance30TableEntry OBJECT-TYPE
SYNTAX Performance30TableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the performance30Table."
INDEX { performance30NearIndex, performance30FarIndex, performance30InterfaceIndex, performance30Index }
::= { performance30Table 1 }
Performance30TableEntry ::=
SEQUENCE
{
performance30NearIndex INTEGER,
performance30FarIndex INTEGER,
performance30InterfaceIndex INTEGER,
performance30Index INTEGER,
performance30ES INTEGER,
performance30BES INTEGER,
performance30SES INTEGER,
performance30UAS INTEGER,
performance30LOFC INTEGER,
performance30CSS INTEGER,
performance30CRCES INTEGER,
performance30OOFS INTEGER,
performance30LOSS INTEGER,
performance30AISS INTEGER,
performance30RAS INTEGER,
performance30BPVS INTEGER,
performance30timestamp TimeTicks
}
performance30NearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { performance30TableEntry 1 }
performance30FarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { performance30TableEntry 2 }
performance30InterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the interface."
::= { performance30TableEntry 3 }
performance30Index OBJECT-TYPE
SYNTAX INTEGER
{
performance30Summary(1),
performance30day1(2),
performance30day2(3),
performance30day3(4),
performance30day4(5),
performance30day5(6),
performance30day6(7),
performance30day7(8),
performance30day8(9),
performance30day9(10),
performance30day10(11),
performance30day11(12),
performance30day12(13),
performance30day13(14),
performance30day14(15),
performance30day15(16),
performance30day16(17),
performance30day17(18),
performance30day18(19),
performance30day19(20),
performance30day20(21),
performance30day21(22),
performance30day22(23),
performance30day23(24),
performance30day24(25),
performance30day25(26),
performance30day26(27),
performance30day27(28),
performance30day28(29),
performance30day29(30),
performance30day30(31)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the 30-day performance table."
::= { performance30TableEntry 4 }
performance30ES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds for the 1-day period."
::= { performance30TableEntry 5 }
performance30BES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Bursty Errored Seconds for the 1-day period."
::= { performance30TableEntry 6 }
performance30SES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Severely Errored Seconds for the 1-day period."
::= { performance30TableEntry 7 }
performance30UAS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Unavailable Seconds for the 1-day period."
::= { performance30TableEntry 8 }
performance30LOFC OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Loss of Frame Counts for the 1-day period."
::= { performance30TableEntry 9 }
performance30CSS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Controlled Slip Seconds for the 1-day period."
::= { performance30TableEntry 10 }
performance30CRCES OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of CRC Errored Seconds for the 1-day period."
::= { performance30TableEntry 11 }
performance30OOFS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Out of Frame Seconds for the 1-day period."
::= { performance30TableEntry 12 }
performance30LOSS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Loss of Signal Seconds for the 1-day period."
::= { performance30TableEntry 13 }
performance30AISS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Alarm Indication Signal Seconds for the 1-day period."
::= { performance30TableEntry 14 }
performance30RAS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Remote Alarm (Yellow) Seconds for the 1-day period."
::= { performance30TableEntry 15 }
performance30BPVS OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Bipolar Violation Seconds for the 1-day period."
::= { performance30TableEntry 16 }
performance30timestamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the statistics were last updated."
::= { performance30TableEntry 17 }
-- itable
-- requests a list of all interfaces on a device
iTable OBJECT-TYPE
SYNTAX SEQUENCE OF ITableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface table."
::= { itable 1 }
iTableEntry OBJECT-TYPE
SYNTAX ITableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the interface table."
INDEX { iTableNearIndex, iTableFarIndex, iTableIndex }
::= { iTable 1 }
ITableEntry ::=
SEQUENCE
{
iTableNearIndex INTEGER,
iTableFarIndex INTEGER,
iTableIndex INTEGER,
iDescription DisplayString,
iType INTEGER,
iSlot INTEGER,
iPort INTEGER,
iStatus INTEGER
}
iTableNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { iTableEntry 1 }
iTableFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { iTableEntry 2 }
iTableIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the interface table, used for addressing in above tables."
::= { iTableEntry 3 }
iDescription OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..80) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of the interface."
::= { iTableEntry 4 }
iType OBJECT-TYPE
SYNTAX INTEGER
{
disabled(0),
v35(1),
eia530(2),
rs232(3),
voice(4),
hsdata(5),
dualt1dte(6),
dualddsv1(7),
hexdds(8),
ocudp(9),
x21(10),
dualddsv2(11),
rfdl(128),
alt(129),
t1dte(130),
didte(131),
t1ntw(132),
e1ntw(133),
ddsntw(134),
ddsdte(135),
ddsdbu(136),
fxs(137),
fxo(138),
eandm(139),
e1sig(192)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Enumerated interface type."
::= { iTableEntry 5 }
iSlot OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device-dependent slot in which the interface resides."
::= { iTableEntry 6 }
iPort OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Device-dependent port in which the interface resides."
::= { iTableEntry 7 }
iStatus OBJECT-TYPE
SYNTAX INTEGER
{
iStatusOther(1),
iStatusOK(2),
iStatusErrored(3),
iStatusAlarmed(4),
iStatusTesting(5),
iStatusUnassigned(6),
iStatusLoopDetected(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the interface."
::= { iTableEntry 8 }
-- traplog
-- a table of the most recent snmp traps
-- note that the near and far indices are simply elements in the table,
-- not indices as in the above tables...
traplogTable OBJECT-TYPE
SYNTAX SEQUENCE OF TraplogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The traplog table."
::= { traplog 1 }
traplogEntry OBJECT-TYPE
SYNTAX TraplogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the traplog table."
INDEX { traplogIndex }
::= { traplogTable 1 }
TraplogEntry ::=
SEQUENCE
{
traplogIndex INTEGER,
traplogNearIndex INTEGER,
traplogFarIndex INTEGER,
traplogInterfaceIndex INTEGER,
traplogTrapNum INTEGER,
traplogTimeStamp DisplayString,
traplogDeviceType INTEGER,
traplogOID1 DisplayString,
traplogDescription1 DisplayString,
traplogValue1 DisplayString,
traplogOID2 DisplayString,
traplogDescription2 DisplayString,
traplogValue2 DisplayString,
traplogOID3 DisplayString,
traplogDescription3 DisplayString,
traplogValue3 DisplayString
}
traplogIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the traplog table."
::= { traplogEntry 1 }
traplogNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the near device."
::= { traplogEntry 2 }
traplogFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the far device."
::= { traplogEntry 3 }
traplogInterfaceIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the interface."
::= { traplogEntry 4 }
traplogTrapNum OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SNMP trap id."
::= { traplogEntry 5 }
traplogTimeStamp OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..40))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time the SNMP was generated."
::= { traplogEntry 6 }
traplogDeviceType OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
none(2),
t12000(3),
e12048(4),
e13021(5),
t13000(6),
t13001(7),
t13002(8),
t13030(9),
t13060(10),
t13101(11),
t13102(12),
t13111(13),
t13112(14),
dds4001(15),
dds4101(16),
dds4051(17),
dds4151(18),
dds41TDM(19),
generic54016(20),
wanSuite(21)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Specifies the device type for the trap."
::= { traplogEntry 7 }
traplogOID1 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMP Object ID of 1st varbind."
::= { traplogEntry 8 }
traplogDescription1 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of 1st varbind."
::= { traplogEntry 9 }
traplogValue1 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of of 1st varbind."
::= { traplogEntry 10 }
traplogOID2 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMP Object ID of 2nd varbind."
::= { traplogEntry 11 }
traplogDescription2 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of 2nd varbind."
::= { traplogEntry 12 }
traplogValue2 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of of 2nd varbind."
::= { traplogEntry 13 }
traplogOID3 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"SNMP Object ID of 3rd varbind."
::= { traplogEntry 14 }
traplogDescription3 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Description of 3rd varbind."
::= { traplogEntry 15 }
traplogValue3 OBJECT-TYPE
SYNTAX DisplayString(SIZE(0..80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Value of of 3rd varbind."
::= { traplogEntry 16 }
-- end traplogTableEntry
traplogDeleteEntry OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing the index of a trap to this object will delete
the trap entry. Writing an index value of 0 will delete
all entries."
::= { traplog 2 }
traplogSortOption OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
ascendingtimestamp(2),
ascendingunit(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the order in which traps are presented."
::= { traplog 3 }
traplogLastTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The timestamp of the newest trap in the trap log."
::= { traplog 4 }
-- unitUtilities
-- a table of unit utilities options
unitUtilitiesTable OBJECT-TYPE
SYNTAX SEQUENCE OF UnitUtilitiesTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unit utilities table."
::= { unitUtilities 1 }
unitUtilitiesTableEntry OBJECT-TYPE
SYNTAX UnitUtilitiesTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the unit utilities table."
INDEX { unitUtilitiesNearIndex, unitUtilitiesFarIndex }
::= { unitUtilitiesTable 1 }
UnitUtilitiesTableEntry ::=
SEQUENCE
{
unitUtilitiesNearIndex INTEGER,
unitUtilitiesFarIndex INTEGER,
unitUtilitiesLocalPassword DisplayString,
unitUtilitiesTime DisplayString,
unitUtilitiesDate DisplayString,
unitUtilitiesMaintenanceReset INTEGER,
unitUtilitiesAlarmResetTimer INTEGER,
unitUtilitiesAlarmClear INTEGER,
unitUtilitiesSaveConfig INTEGER,
unitUtilitiesRestartStatus INTEGER,
unitUtilitiesReadOnlyPassword DisplayString,
unitUtilitiesPasswordLockoutEnable INTEGER,
unitUtilitiesPasswordLockoutStatus INTEGER,
unitUtilitiesPasswordLockoutClear INTEGER
}
unitUtilitiesNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { unitUtilitiesTableEntry 1 }
unitUtilitiesFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { unitUtilitiesTableEntry 2 }
unitUtilitiesLocalPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The password for local access to a device (VT100, front panel)."
::= { unitUtilitiesTableEntry 3 }
unitUtilitiesTime OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..8) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is the current time as known to the device. The current time may be entered in this field using the HHMMSS format. For example, 3:45AM is entered as 034500 and 3:45PM is entered as 154500."
::= { unitUtilitiesTableEntry 4 }
unitUtilitiesDate OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..8) )
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This string is the current date as known to the device. The current date may be entered in this field using the MMDDYY format. For example, July 4, 1997 is entered as 070497."
::= { unitUtilitiesTableEntry 5 }
unitUtilitiesMaintenanceReset OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
reset(2),
restart(3),
resetProfile1(4),
resetProfile2(5),
resetProfile3(6),
resetProfile4(7),
resetProfile5(8),
resetProfile6(9),
resetProfile7(10),
resetProfile8(11),
resetProfile9(12),
resetProfile10(13),
resetProfile11(14),
resetProfile12(15),
resetProfile13(16),
resetProfile14(17),
resetProfile15(18),
resetProfile16(19),
resetProfile17(20),
resetProfile18(21),
resetProfile19(22),
resetProfile20(23),
resetProfile21(24)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows resetting the device to default values by reloading the start-up default configuration parameters."
::= { unitUtilitiesTableEntry 6 }
unitUtilitiesAlarmResetTimer OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field allows setting a timer which will cause all existing alarms on the device to be cleared upon expiration. The counter is in seconds."
::= { unitUtilitiesTableEntry 7 }
unitUtilitiesAlarmClear OBJECT-TYPE
SYNTAX INTEGER
{
utilitiesAlarmClearOther(1),
utilitiesAlarmClearNow(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Writing a value of utilitiesAlarmClearNow(2) to this field causes all existing alarms to be cleared immediately."
::= { unitUtilitiesTableEntry 8 }
unitUtilitiesSaveConfig OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
saveConfig(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field commands the unit to save its configuration."
::= { unitUtilitiesTableEntry 9 }
unitUtilitiesRestartStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
notNeeded(2),
recommended(3),
required(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates if the unit configuration needs to be saved and restarted.
notNeeded - A save and restart is not needed at this time.
recommended - A save and restart is recommended for optimal performance but not required.
required - A save and restart is required for the unit to implement the altered configuration."
::= { unitUtilitiesTableEntry 10 }
unitUtilitiesReadOnlyPassword OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The password for read only access to a device (VT100, front panel)."
::= { unitUtilitiesTableEntry 11 }
unitUtilitiesPasswordLockoutEnable OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used to enable or disable the password lockout feature."
::= { unitUtilitiesTableEntry 12 }
unitUtilitiesPasswordLockoutStatus OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3),
locked(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates if the password lockout feature is enabled
or disabled, and if it is enabled this parameter may reflect if the
password is indeed locked."
::= { unitUtilitiesTableEntry 13 }
unitUtilitiesPasswordLockoutClear OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
unlock(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is used to unlock a locked password."
::= { unitUtilitiesTableEntry 14 }
-- ----------------------------------------------------------------------
-- netAPS section
-- ----------------------------------------------------------------------
netAPSConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF NetAPSConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"One to One network Automatic Protection Switching (APS) configuration parameters table."
::= { netAPS 1 }
netAPSConfigTableEntry OBJECT-TYPE
SYNTAX NetAPSConfigTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the netAPSConfigTable."
INDEX { netAPSConfigNearIndex, netAPSConfigFarIndex, netAPSConfigifIndex }
::= { netAPSConfigTable 1 }
NetAPSConfigTableEntry ::=
SEQUENCE
{
netAPSConfigNearIndex INTEGER,
netAPSConfigFarIndex INTEGER,
netAPSConfigifIndex INTEGER,
netAPSConfigOtherifIndex INTEGER,
netAPSConfigMode INTEGER,
netAPSConfigRevert INTEGER,
netAPSConfigManualInhibit INTEGER,
netAPSConfigAvailabilityTimer INTEGER,
netAPSConfigESThreshold INTEGER,
netAPSConfigESCount INTEGER,
netAPSConfigESSwitchEvent INTEGER,
netAPSConfigCSESThreshold INTEGER,
netAPSConfigCSESCount INTEGER,
netAPSConfigCSESSwitchEvent INTEGER,
netAPSConfigStatusBitmap INTEGER,
netAPSConfigStatusString DisplayString,
netAPSConfigTimeInInterval INTEGER,
netAPSConfigValidIntervals INTEGER,
netAPSConfigValidDays INTEGER,
netAPSConfigReset INTEGER
}
netAPSConfigNearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { netAPSConfigTableEntry 1 }
netAPSConfigFarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { netAPSConfigTableEntry 2 }
netAPSConfigifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the MIB-II ifIndex."
::= { netAPSConfigTableEntry 3 }
netAPSConfigOtherifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"MIB-II ifIndex of the other interface involved with the APS."
::= { netAPSConfigTableEntry 4 }
netAPSConfigMode OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
tr54017(2),
autoABswitch(3),
masterAltCarrier(4),
slaveAltCarrier(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"tr54017 - Implements TR54017
autoABswitch - Implements a single ended A/B switch between two independent lines
masterAltCarrier - Master side of alternate carrier APS
slaveAltCarrier - Slave side of alternate carrier APS"
::= { netAPSConfigTableEntry 5 }
netAPSConfigRevert OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
enabled(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"disabled - Service does not return to the primary line until the backup line fails.
enabled - Service automatically returns to the primary line when the primary line is able to carry service again."
::= { netAPSConfigTableEntry 6 }
netAPSConfigManualInhibit OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
disabled(2),
thisLine(3),
otherLine(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Disabled - Neither line is manually inhibited from carrying service.
ThisLine - This line is manually inhibited from carrying service.
OtherLine - The other line is manually inhibited from carrying service."
::= { netAPSConfigTableEntry 7 }
netAPSConfigAvailabilityTimer OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The line availability timer represents the minimum amount of time that is free of errors in active events that must expire before this line is returned to service availability.
The timer is in seconds ranging from 0 - 900 seconds."
::= { netAPSConfigTableEntry 8 }
netAPSConfigESThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is the number of erred seconds in a 15-minute period needed before a transfer request is triggered.
A setting of zero disables this trigger."
::= { netAPSConfigTableEntry 9 }
netAPSConfigESCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is the number of erred seconds in the current 15-minute interval.
This count is reset at the beginning of a new 15-minute interval."
::= { netAPSConfigTableEntry 10 }
netAPSConfigESSwitchEvent OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
normal(2),
triggered(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if exceeding the ES threshold caused a transfer to the other line."
::= { netAPSConfigTableEntry 11 }
netAPSConfigCSESThreshold OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is the number of consecutive SES needed before a transfer request is triggered.
A setting of zero disables this trigger."
::= { netAPSConfigTableEntry 12 }
netAPSConfigCSESCount OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is the number of consecutive SES detected.
This count stops when 900 is reached and is reset when a non-SES is detected."
::= { netAPSConfigTableEntry 13 }
netAPSConfigCSESSwitchEvent OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
normal(2),
triggered(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This status indicates if exceeding the consecutive SES threshold caused a transfer to the other line."
::= { netAPSConfigTableEntry 14 }
netAPSConfigStatusBitmap OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TR54017 defined bitmap status for this line interface:
Value is 1 if this line is carrying service.
Value is 2 if this line is in a failed state.
Value is 4 if this line is in an inhibit state.
Value is 8 if this line is looped back.
Value is 16 if the other line is in a failed state.
Value is 32 if the other line is in an inhibit state.
Value is 64 if the other line is looped back.
Value is 128 if the manual inhibit is active
Note that multiple status conditions may exist at the same time.
The failed state is determined when carrier fails, or the ES threshold is reached, or the consecutive SES threshold is reached.
The inhibit state is set when the manual inhibit setting affects this line or the line is inhibited by the remote end."
::= { netAPSConfigTableEntry 15 }
netAPSConfigStatusString OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..80) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string version of netAPSConfigStatusBitmap for this line status bits"
::= { netAPSConfigTableEntry 16 }
netAPSConfigTimeInInterval OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds into the netAPSHist24Table current interval."
::= { netAPSConfigTableEntry 17 }
netAPSConfigValidIntervals OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of valid intervals in the netAPSHist24Table"
::= { netAPSConfigTableEntry 18 }
netAPSConfigValidDays OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of valid days in the netAPSHist30Table"
::= { netAPSConfigTableEntry 19 }
netAPSConfigReset OBJECT-TYPE
SYNTAX INTEGER
{
other(1),
clearAlarms(2),
clearHistory(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This action parameter does the following when the given value is set:
other - Does nothing
clearAlarms - Clear the APS events and counts
clearHistory - Clear the APS history table statistics"
::= { netAPSConfigTableEntry 20 }
-- ----------------------------------------------------------------------
netAPSHist24Table OBJECT-TYPE
SYNTAX SEQUENCE OF NetAPSHist24TableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"History table, contains Network APS historical data."
::= { netAPS 2 }
netAPSHist24TableEntry OBJECT-TYPE
SYNTAX NetAPSHist24TableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the netAPSHist24Table."
INDEX { netAPSHist24NearIndex, netAPSHist24FarIndex, netAPSHist24ifIndex, netAPSHist24Index }
::= { netAPSHist24Table 1 }
NetAPSHist24TableEntry ::=
SEQUENCE
{
netAPSHist24NearIndex INTEGER,
netAPSHist24FarIndex INTEGER,
netAPSHist24ifIndex INTEGER,
netAPSHist24Index INTEGER,
netAPSHist24Timestamp TimeTicks,
netAPSHist24StatusBitmap INTEGER,
netAPSHist24StatusString DisplayString,
netAPSHist24Occurrences INTEGER,
netAPSHist24Duration INTEGER
}
netAPSHist24NearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { netAPSHist24TableEntry 1 }
netAPSHist24FarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { netAPSHist24TableEntry 2 }
netAPSHist24ifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the MIB-II ifIndex."
::= { netAPSHist24TableEntry 3 }
netAPSHist24Index OBJECT-TYPE
SYNTAX INTEGER
{
statSummary(1),
statCurrent(2),
statPeriod1(3),
statPeriod2(4),
statPeriod3(5),
statPeriod4(6),
statPeriod5(7),
statPeriod6(8),
statPeriod7(9),
statPeriod8(10),
statPeriod9(11),
statPeriod10(12),
statPeriod11(13),
statPeriod12(14),
statPeriod13(15),
statPeriod14(16),
statPeriod15(17),
statPeriod16(18),
statPeriod17(19),
statPeriod18(20),
statPeriod19(21),
statPeriod20(22),
statPeriod21(23),
statPeriod22(24),
statPeriod23(25),
statPeriod24(26),
statPeriod25(27),
statPeriod26(28),
statPeriod27(29),
statPeriod28(30),
statPeriod29(31),
statPeriod30(32),
statPeriod31(33),
statPeriod32(34),
statPeriod33(35),
statPeriod34(36),
statPeriod35(37),
statPeriod36(38),
statPeriod37(39),
statPeriod38(40),
statPeriod39(41),
statPeriod40(42),
statPeriod41(43),
statPeriod42(44),
statPeriod43(45),
statPeriod44(46),
statPeriod45(47),
statPeriod46(48),
statPeriod47(49),
statPeriod48(50),
statPeriod49(51),
statPeriod50(52),
statPeriod51(53),
statPeriod52(54),
statPeriod53(55),
statPeriod54(56),
statPeriod55(57),
statPeriod56(58),
statPeriod57(59),
statPeriod58(60),
statPeriod59(61),
statPeriod60(62),
statPeriod61(63),
statPeriod62(64),
statPeriod63(65),
statPeriod64(66),
statPeriod65(67),
statPeriod66(68),
statPeriod67(69),
statPeriod68(70),
statPeriod69(71),
statPeriod70(72),
statPeriod71(73),
statPeriod72(74),
statPeriod73(75),
statPeriod74(76),
statPeriod75(77),
statPeriod76(78),
statPeriod77(79),
statPeriod78(80),
statPeriod79(81),
statPeriod80(82),
statPeriod81(83),
statPeriod82(84),
statPeriod83(85),
statPeriod84(86),
statPeriod85(87),
statPeriod86(88),
statPeriod87(89),
statPeriod88(90),
statPeriod89(91),
statPeriod90(92),
statPeriod91(93),
statPeriod92(94),
statPeriod93(95),
statPeriod94(96),
statPeriod95(97),
statPeriod96(98)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the 24-hour history table."
::= { netAPSHist24TableEntry 4 }
netAPSHist24Timestamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the statistics were last updated."
::= { netAPSHist24TableEntry 5 }
netAPSHist24StatusBitmap OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TR54017 defined bitmap status for this line interface:
Value is 1 if this line is carrying service.
Value is 2 if this line is in a failed state.
Value is 4 if this line is in an inhibit state.
Value is 8 if this line is looped back.
Value is 16 if the other line is in a failed state.
Value is 32 if the other line is in an inhibit state.
Value is 64 if the other line is looped back.
Value is 128 if the manual inhibit is active
Note that multiple status conditions may exist at the same time.
The failed state is determined when carrier fails, or the ES threshold is reached, or the consecutive SES threshold is reached.
The inhibit state is set when the manual inhibit setting affects this line or the line is inhibited by the remote end."
::= { netAPSHist24TableEntry 6 }
netAPSHist24StatusString OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..80) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string version of netAPSHist24StatusBitmap for this line status bits"
::= { netAPSHist24TableEntry 7 }
netAPSHist24Occurrences OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is the total number of times the service was transferred between lines."
::= { netAPSHist24TableEntry 8 }
netAPSHist24Duration OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is the number of seconds the service was provided on this line."
::= { netAPSHist24TableEntry 9 }
-- ----------------------------------------------------------------------
netAPSHist30Table OBJECT-TYPE
SYNTAX SEQUENCE OF NetAPSHist30TableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"History table, contains Network APS 30-day historical data."
::= { netAPS 3 }
netAPSHist30TableEntry OBJECT-TYPE
SYNTAX NetAPSHist30TableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the netAPSHist30Table."
INDEX { netAPSHist30NearIndex, netAPSHist30FarIndex, netAPSHist30ifIndex, netAPSHist30Index }
::= { netAPSHist30Table 1 }
NetAPSHist30TableEntry ::=
SEQUENCE
{
netAPSHist30NearIndex INTEGER,
netAPSHist30FarIndex INTEGER,
netAPSHist30ifIndex INTEGER,
netAPSHist30Index INTEGER,
netAPSHist30Timestamp TimeTicks,
netAPSHist30StatusBitmap INTEGER,
netAPSHist30StatusString DisplayString,
netAPSHist30Occurrences INTEGER,
netAPSHist30Duration INTEGER
}
netAPSHist30NearIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the near device."
::= { netAPSHist30TableEntry 1 }
netAPSHist30FarIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the far device."
::= { netAPSHist30TableEntry 2 }
netAPSHist30ifIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Selects the MIB-II ifIndex."
::= { netAPSHist30TableEntry 3 }
netAPSHist30Index OBJECT-TYPE
SYNTAX INTEGER
{
statSummary(1),
statDay1(2),
statDay2(3),
statDay3(4),
statDay4(5),
statDay5(6),
statDay6(7),
statDay7(8),
statDay8(9),
statDay9(10),
statDay10(11),
statDay11(12),
statDay12(13),
statDay13(14),
statDay14(15),
statDay15(16),
statDay16(17),
statDay17(18),
statDay18(19),
statDay19(20),
statDay20(21),
statDay21(22),
statDay22(23),
statDay23(24),
statDay24(25),
statDay25(26),
statDay26(27),
statDay27(28),
statDay28(29),
statDay29(30),
statDay30(31)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index into the 30-day history table."
::= { netAPSHist30TableEntry 4 }
netAPSHist30Timestamp OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of sysUpTime when the statistics were last updated."
::= { netAPSHist30TableEntry 5 }
netAPSHist30StatusBitmap OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"TR54017 defined bitmap status for this line interface:
Value is 1 if this line is carrying service.
Value is 2 if this line is in a failed state.
Value is 4 if this line is in an inhibit state.
Value is 8 if this line is looped back.
Value is 16 if the other line is in a failed state.
Value is 32 if the other line is in an inhibit state.
Value is 64 if the other line is looped back.
Value is 128 if the manual inhibit is active
Note that multiple status conditions may exist at the same time.
The failed state is determined when carrier fails, or the ES threshold is reached, or the consecutive SES threshold is reached.
The inhibit state is set when the manual inhibit setting affects this line or the line is inhibited by the remote end."
::= { netAPSHist30TableEntry 6 }
netAPSHist30StatusString OBJECT-TYPE
SYNTAX DisplayString( SIZE(0..80) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"ASCII string version of netAPSHist30StatusBitmap for this line status bits"
::= { netAPSHist30TableEntry 7 }
netAPSHist30Occurrences OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is the total number of times the service was transferred between lines."
::= { netAPSHist30TableEntry 8 }
netAPSHist30Duration OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is the number of seconds the service was provided on this line."
::= { netAPSHist30TableEntry 9 }
END