49832 lines
1.6 MiB
49832 lines
1.6 MiB
Webio-Digital-MIB-US DEFINITIONS ::= BEGIN
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.55
|
|
----------------------------------------------------------------
|
|
-- 12.12.2017 New:
|
|
-- wtWebio577xxMQTTLastWillEnable
|
|
-- wtWebio577xxMQTTLastWillTopic
|
|
-- wtWebio577xxMQTTLastWillMsg
|
|
-- wtWebio577xxMQTTLastWillQoS
|
|
-- wtWebio577xxMQTTLastWillRetain
|
|
-- wtWebio577xxMQTTLastWillConnectEnable
|
|
-- wtWebio577xxMQTTLastWillConnectMsg
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.54
|
|
----------------------------------------------------------------
|
|
-- 29.08.2017 New: wtWebio577xxManagerPort
|
|
-- wtWebio577xxMQTT_QoS
|
|
-- wtWebio577xxMQTT_Retain
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.53
|
|
----------------------------------------------------------------
|
|
-- 23.01.2017 New: wtWebio577xxEA12x12
|
|
-- wtWebio577xxEA12x12Uart
|
|
-- wtWebio577xxEA12x6Rel
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.52
|
|
----------------------------------------------------------------
|
|
-- 01.06.2016 New wtWebio577xxEA1x1
|
|
-- wtWebio577xxEA2x2
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.51
|
|
----------------------------------------------------------------
|
|
-- 24.09.2012 Error correction
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.50
|
|
----------------------------------------------------------------
|
|
-- 21.01.2011 TrapReceiver
|
|
-- Syntax correction
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.49
|
|
----------------------------------------------------------------
|
|
-- 27.07.2010 Update TrapReceiver
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.48
|
|
----------------------------------------------------------------
|
|
-- 22.06.2010 Webio
|
|
-- Syntax correction
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.47
|
|
----------------------------------------------------------------
|
|
-- 23.04.2010 New: TrapReceiver Reports
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.46
|
|
----------------------------------------------------------------
|
|
-- 02.02.2010 New: 57638: ERP-Gateway PoE: Internal 24V
|
|
-- 57655: IP-Watcher PoE: Internal 24V
|
|
-- 57656: TrapReceiver 2x2
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.45
|
|
----------------------------------------------------------------
|
|
-- 07.01.2010 New: 57654: IP List Alias Names
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.44
|
|
----------------------------------------------------------------
|
|
-- 24.11.2009 New: 57652: Add on Rate of Change
|
|
-- UDP Remote Port
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.43
|
|
----------------------------------------------------------------
|
|
-- 06.11.2009 New: 57637: WebIO Digital 2x2 mit interner 24V
|
|
-- Versorgung
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.42
|
|
----------------------------------------------------------------
|
|
-- 11.08.2009 Syntax correction
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.41
|
|
----------------------------------------------------------------
|
|
-- 15.06.2009 New: 57652: Rate of change
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.40
|
|
----------------------------------------------------------------
|
|
-- 17.04.2009 New: IP Watcher 57654
|
|
-- New: ERP Gateway 2x2 Digital 57635
|
|
-- New: ERP Gateway 6xRelais 57636
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.39
|
|
----------------------------------------------------------------
|
|
-- 03.02.2009 New: WebIO Digital 6x6 Logger 57650
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.37
|
|
----------------------------------------------------------------
|
|
-- 17.11.2008 Correction numbering OutputPortEntry
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.36
|
|
----------------------------------------------------------------
|
|
-- 03.09.2008 New: Web-Count 57652
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.35
|
|
----------------------------------------------------------------
|
|
-- 20.08.2008 New: US Release Text
|
|
-- Extensions
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.34
|
|
----------------------------------------------------------------
|
|
-- 08.08.2008 New: Web-Alarm 57651
|
|
-- Extensions
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.33
|
|
----------------------------------------------------------------
|
|
-- 24.06.2008 All: OutputState in group xxxInOut now read-write
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.32
|
|
----------------------------------------------------------------
|
|
-- 14.03.2008 WebAlarm 6x6
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.31
|
|
----------------------------------------------------------------
|
|
-- 23.05.2007 Webio Digital
|
|
-- new: Read(Write) Inputs/Outputs bitwise
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.30
|
|
----------------------------------------------------------------
|
|
-- 08.12.2006 Webio Digital
|
|
-- new: 57634
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.29
|
|
----------------------------------------------------------------
|
|
-- 09.11.2006 Webio Digital
|
|
-- DHCP enable
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.28
|
|
----------------------------------------------------------------
|
|
-- 04.05.2006 #57632, Webio Digital
|
|
-- new OEM device
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.27
|
|
----------------------------------------------------------------
|
|
-- 10.02.2006 #57630/1, Webio Digital
|
|
-- Incremental Counter
|
|
-- New: #57633 2x2 Webio Digital
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.26
|
|
----------------------------------------------------------------
|
|
-- 05.08.2005 #57630/1/2, Webio Digital
|
|
-- CRON time functions
|
|
-- FTP functions
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.25
|
|
----------------------------------------------------------------
|
|
-- 02.06.2005 #57630/1/2, Webio Digital
|
|
-- Trap NMS annotations
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.24
|
|
----------------------------------------------------------------
|
|
-- 10.05.2005 #57630/1/2, Webio Digital
|
|
-- Binary Mode: BIN-TCP-CLIENT-SERVER-HTTP-PORT
|
|
-- Binary Mode: BIN-TCP-SERVER-CLIENT-HTTP-PORT
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.23
|
|
----------------------------------------------------------------
|
|
-- 19.04.2005 #57630/1/2, Webio Digital
|
|
-- Mail Authentication
|
|
-- PortInputMode: Change detection enable
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.22
|
|
----------------------------------------------------------------
|
|
-- 15.03.2005 #57630/1/2, Webio Digital
|
|
-- variable HTTP port
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.21
|
|
----------------------------------------------------------------
|
|
-- 17.02.2005 #57630/1/2, Webio Digital
|
|
-- 4 additional traps; new input/output alarm trigger
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.20
|
|
----------------------------------------------------------------
|
|
-- 13.12.2004 #57630/1/2, Webio Digital
|
|
-- New: Size setoutput, alarminputtrigger, alarmoutputtrigger
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.19
|
|
----------------------------------------------------------------
|
|
-- 02.11.2004 #57630/1/2, Webio Digital
|
|
-- New: Syslog
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.18
|
|
----------------------------------------------------------------
|
|
-- 12.07.2004 #57630/1/2, Webio Digital
|
|
-- New: HTTP Input Trigger
|
|
-- Diagnosis
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.17
|
|
----------------------------------------------------------------
|
|
-- 28.06.2004 #57630/1/2, Webio Digital
|
|
-- Neu: Pulse Mode
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.16
|
|
----------------------------------------------------------------
|
|
-- 16.04.2004 New: #57632, Webio Digital EA24oem
|
|
--
|
|
-- #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- wtWebioEA12x12InputCounterClear
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.15
|
|
----------------------------------------------------------------
|
|
-- 27.02.2004 #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- Length changed to 32 Bit:
|
|
-- wtWebioEA12x12InputValue
|
|
-- wtWebioEA12x12OutputValue
|
|
-- wtWebioEA12x12LoadControlView
|
|
-- wtWebioEA12x12LCShutDownView
|
|
-- wtWebioEA12x12SetOutput
|
|
-- wtWebioEA12x12AlarmInputTrigger
|
|
-- wtWebioEA12x12AlarmOutputTrigger
|
|
-- wtWebioEA12x12PortOutputSafetyState
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.14
|
|
----------------------------------------------------------------
|
|
-- 16.02.2004 #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- Text: Location, Contact
|
|
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
|
|
-- Alarm: ColdStart / WarmStart trigger
|
|
--
|
|
-- #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New:
|
|
-- Alarm Hysteresis
|
|
-- Alarm Clear Traps and Mails
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.13
|
|
----------------------------------------------------------------
|
|
-- 05.02.2004 #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New:
|
|
-- Text: Location, Contact
|
|
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
|
|
-- Alarm: ColdStart / WarmStart trigger
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.12
|
|
----------------------------------------------------------------
|
|
-- 05.11.2003 #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New features:
|
|
-- Mail : Option CSV attachment
|
|
-- Port : Offset calibration
|
|
-- Alarm : TCP Client mode
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.11
|
|
----------------------------------------------------------------
|
|
-- 28.10.2003 #57630/1, Webio Digital EA12x12
|
|
-- New features:
|
|
-- Alarm : TCP Client mode
|
|
-- Inputs: Pulse filter
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.10
|
|
----------------------------------------------------------------
|
|
-- 22.07.2003 #57630, Webio Digital EA12x12
|
|
-- New navigation tree, new binary modes
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.09
|
|
----------------------------------------------------------------
|
|
-- 24.03.2003 Trap Enterprise (Type 1, 2) corrected
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.08
|
|
----------------------------------------------------------------
|
|
-- 04.03.2003 reconciled the language versions DE/US
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.07
|
|
----------------------------------------------------------------
|
|
-- 25.02.2003 Correction: wtWebioEA12x12LoadControl
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.06
|
|
----------------------------------------------------------------
|
|
-- 24.02.2003 New:
|
|
-- #57630, Webio EA12x12, LoadControl Group
|
|
-- Correction: Trap variable names
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.05
|
|
----------------------------------------------------------------
|
|
-- 21.01.2003 New:
|
|
-- #57630, Webio EA12x12
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.04
|
|
----------------------------------------------------------------
|
|
-- 02.01.2003 New:
|
|
-- #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer, 8 alarms
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.03
|
|
----------------------------------------------------------------
|
|
-- 21.11.2002 New:
|
|
-- #57604, 2xWebThermometer, BOOTP, StartupSite
|
|
-- #57603, 8xWebThermometer, BOOTP, StartupSite
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.02
|
|
----------------------------------------------------------------
|
|
-- 26.07.2002 New:
|
|
-- #57604, 2xWebThermometer
|
|
-- #57603, 8xWebThermometer
|
|
--
|
|
|
|
IMPORTS
|
|
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215
|
|
DisplayString, PhysAddress FROM RFC1213-MIB
|
|
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
|
|
|
|
|
|
-- IpAddress ::=
|
|
-- [APPLICATION 0]
|
|
-- IMPLICIT OCTET STRING (SIZE (4))
|
|
-- Counter ::=
|
|
-- [APPLICATION 1]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
-- Gauge ::=
|
|
-- [APPLICATION 2]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
-- TimeTicks ::=
|
|
-- [APPLICATION 3]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
|
|
|
|
-- DisplayString ::= OCTET STRING
|
|
-- PhysAddress ::= OCTET STRING
|
|
|
|
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
|
|
-- privat OBJECT IDENTIFIER ::= { internet 4 }
|
|
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
|
|
|
|
|
|
|
|
-- Wiesemann & Theis Com-Server MIB
|
|
|
|
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
|
|
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
|
|
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
|
|
|
|
-- wtWebio Tree
|
|
|
|
wtWebioEA12x12 OBJECT IDENTIFIER ::= { wtWebio 4 }
|
|
wtWebioEA2x2 OBJECT IDENTIFIER ::= { wtWebio 13 }
|
|
wtWebioEA24oem OBJECT IDENTIFIER ::= { wtWebio 14 }
|
|
wtWebioEA12x6Rel OBJECT IDENTIFIER ::= { wtWebio 19 }
|
|
wtWebAlarm6x6 OBJECT IDENTIFIER ::= { wtWebio 20 }
|
|
wtWebCount6 OBJECT IDENTIFIER ::= { wtWebio 22 }
|
|
wtWebioEA6x6 OBJECT IDENTIFIER ::= { wtWebio 24 }
|
|
wtWebioEA2x2ERP OBJECT IDENTIFIER ::= { wtWebio 25 }
|
|
wtWebioEA12x6RelERP OBJECT IDENTIFIER ::= { wtWebio 26 }
|
|
wtIpWatcher OBJECT IDENTIFIER ::= { wtWebio 27 }
|
|
wtWebioEA2x2-24V OBJECT IDENTIFIER ::= { wtWebio 30 }
|
|
wtWebioEA2x2ERP-24V OBJECT IDENTIFIER ::= { wtWebio 31 }
|
|
wtIpWatcher-24V OBJECT IDENTIFIER ::= { wtWebio 32 }
|
|
wtTrapReceiver2x2 OBJECT IDENTIFIER ::= { wtWebio 33 }
|
|
|
|
wtWebio577xxEA1x1 OBJECT IDENTIFIER ::= { wtWebio 48 }
|
|
wtWebio577xxEA12x12 OBJECT IDENTIFIER ::= { wtWebio 49 }
|
|
wtWebio577xxEA12x12Uart OBJECT IDENTIFIER ::= { wtWebio 50 }
|
|
wtWebio577xxEA12x6Rel OBJECT IDENTIFIER ::= { wtWebio 51 }
|
|
wtWebio577xxEA2x2 OBJECT IDENTIFIER ::= { wtWebio 52 }
|
|
|
|
-- wtWebio577xxEA1x1 Tree
|
|
|
|
wtWebio577xxEA1x1InOut OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1 1 }
|
|
wtWebio577xxEA1x1SessCntrl OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1 2 }
|
|
wtWebio577xxEA1x1Config OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1 3 }
|
|
wtWebio577xxEA1x1Diag OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1 4 }
|
|
|
|
-- wtWebio577xxEA1x1Config Tree
|
|
|
|
wtWebio577xxEA1x1Device OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Config 1 }
|
|
wtWebio577xxEA1x1Ports OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Config 2 }
|
|
wtWebio577xxEA1x1Manufact OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Config 3 }
|
|
|
|
-- wtWebio577xxEA1x1Device Tree
|
|
|
|
wtWebio577xxEA1x1Text OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 1 }
|
|
wtWebio577xxEA1x1TimeDate OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 2 }
|
|
wtWebio577xxEA1x1Basic OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 3 }
|
|
wtWebio577xxEA1x1OutputMode OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 4 }
|
|
wtWebio577xxEA1x1Alarm OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Device 5 }
|
|
|
|
-- wtWebio577xxEA1x1Basic Tree
|
|
|
|
wtWebio577xxEA1x1Network OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 1 }
|
|
wtWebio577xxEA1x1HTTP OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 2 }
|
|
wtWebio577xxEA1x1Mail OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 3 }
|
|
wtWebio577xxEA1x1SNMP OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 4 }
|
|
wtWebio577xxEA1x1UDP OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 5 }
|
|
wtWebio577xxEA1x1Binary OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 6 }
|
|
wtWebio577xxEA1x1Syslog OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 7 }
|
|
wtWebio577xxEA1x1FTP OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 8 }
|
|
wtWebio577xxEA1x1MQTT OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 12 }
|
|
wtWebio577xxEA1x1REST OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1Basic 13 }
|
|
|
|
-- wtWebio577xxEA1x1TimeDate Tree
|
|
|
|
wtWebio577xxEA1x1TimeZone OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1TimeDate 1 }
|
|
wtWebio577xxEA1x1TimeServer OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1TimeDate 2 }
|
|
wtWebio577xxEA1x1DeviceClock OBJECT IDENTIFIER ::= { wtWebio577xxEA1x1TimeDate 3 }
|
|
|
|
-- wtWebio577xxEA2x2 Tree
|
|
|
|
wtWebio577xxEA2x2InOut OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2 1 }
|
|
wtWebio577xxEA2x2SessCntrl OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2 2 }
|
|
wtWebio577xxEA2x2Config OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2 3 }
|
|
wtWebio577xxEA2x2Diag OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2 4 }
|
|
|
|
-- wtWebio577xxEA2x2Config Tree
|
|
|
|
wtWebio577xxEA2x2Device OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Config 1 }
|
|
wtWebio577xxEA2x2Ports OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Config 2 }
|
|
wtWebio577xxEA2x2Manufact OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Config 3 }
|
|
|
|
-- wtWebio577xxEA2x2Device Tree
|
|
|
|
wtWebio577xxEA2x2Text OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 1 }
|
|
wtWebio577xxEA2x2TimeDate OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 2 }
|
|
wtWebio577xxEA2x2Basic OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 3 }
|
|
wtWebio577xxEA2x2OutputMode OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 4 }
|
|
wtWebio577xxEA2x2Alarm OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Device 5 }
|
|
|
|
-- wtWebio577xxEA2x2Basic Tree
|
|
|
|
wtWebio577xxEA2x2Network OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 1 }
|
|
wtWebio577xxEA2x2HTTP OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 2 }
|
|
wtWebio577xxEA2x2Mail OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 3 }
|
|
wtWebio577xxEA2x2SNMP OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 4 }
|
|
wtWebio577xxEA2x2UDP OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 5 }
|
|
wtWebio577xxEA2x2Binary OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 6 }
|
|
wtWebio577xxEA2x2Syslog OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 7 }
|
|
wtWebio577xxEA2x2FTP OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 8 }
|
|
wtWebio577xxEA2x2MQTT OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 12 }
|
|
wtWebio577xxEA2x2REST OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2Basic 13 }
|
|
|
|
-- wtWebio577xxEA2x2TimeDate Tree
|
|
|
|
wtWebio577xxEA2x2TimeZone OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2TimeDate 1 }
|
|
wtWebio577xxEA2x2TimeServer OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2TimeDate 2 }
|
|
wtWebio577xxEA2x2DeviceClock OBJECT IDENTIFIER ::= { wtWebio577xxEA2x2TimeDate 3 }
|
|
|
|
-- wtWebioEA2x2 Tree
|
|
|
|
wtWebioEA2x2InOut OBJECT IDENTIFIER ::= { wtWebioEA2x2 1 }
|
|
wtWebioEA2x2SessCntrl OBJECT IDENTIFIER ::= { wtWebioEA2x2 2 }
|
|
wtWebioEA2x2Config OBJECT IDENTIFIER ::= { wtWebioEA2x2 3 }
|
|
wtWebioEA2x2Diag OBJECT IDENTIFIER ::= { wtWebioEA2x2 4 }
|
|
|
|
-- wtWebioEA2x2Config Tree
|
|
|
|
wtWebioEA2x2Device OBJECT IDENTIFIER ::= { wtWebioEA2x2Config 1 }
|
|
wtWebioEA2x2Ports OBJECT IDENTIFIER ::= { wtWebioEA2x2Config 2 }
|
|
wtWebioEA2x2Manufact OBJECT IDENTIFIER ::= { wtWebioEA2x2Config 3 }
|
|
|
|
-- wtWebioEA2x2Device Tree
|
|
|
|
wtWebioEA2x2Text OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 1 }
|
|
wtWebioEA2x2TimeDate OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 2 }
|
|
wtWebioEA2x2Basic OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 3 }
|
|
wtWebioEA2x2OutputMode OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 4 }
|
|
wtWebioEA2x2Alarm OBJECT IDENTIFIER ::= { wtWebioEA2x2Device 5 }
|
|
|
|
-- wtWebioEA2x2Basic Tree
|
|
|
|
wtWebioEA2x2Network OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 1 }
|
|
wtWebioEA2x2HTTP OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 2 }
|
|
wtWebioEA2x2Mail OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 3 }
|
|
wtWebioEA2x2SNMP OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 4 }
|
|
wtWebioEA2x2UDP OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 5 }
|
|
wtWebioEA2x2Binary OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 6 }
|
|
wtWebioEA2x2Syslog OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 7 }
|
|
wtWebioEA2x2FTP OBJECT IDENTIFIER ::= { wtWebioEA2x2Basic 8 }
|
|
|
|
-- wtWebioEA2x2TimeDate Tree
|
|
|
|
wtWebioEA2x2TimeZone OBJECT IDENTIFIER ::= { wtWebioEA2x2TimeDate 1 }
|
|
wtWebioEA2x2TimeServer OBJECT IDENTIFIER ::= { wtWebioEA2x2TimeDate 2 }
|
|
wtWebioEA2x2DeviceClock OBJECT IDENTIFIER ::= { wtWebioEA2x2TimeDate 3 }
|
|
|
|
-- wtWebio577xxEA12x12 Tree
|
|
|
|
wtWebio577xxEA12x12InOut OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12 1 }
|
|
wtWebio577xxEA12x12SessCntrl OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12 2 }
|
|
wtWebio577xxEA12x12Config OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12 3 }
|
|
wtWebio577xxEA12x12Diag OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12 4 }
|
|
|
|
-- wtWebio577xxEA12x12Config Tree
|
|
|
|
wtWebio577xxEA12x12Device OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Config 1 }
|
|
wtWebio577xxEA12x12Ports OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Config 2 }
|
|
wtWebio577xxEA12x12Manufact OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Config 3 }
|
|
|
|
-- wtWebio577xxEA12x12Device Tree
|
|
|
|
wtWebio577xxEA12x12Text OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 1 }
|
|
wtWebio577xxEA12x12TimeDate OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 2 }
|
|
wtWebio577xxEA12x12Basic OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 3 }
|
|
wtWebio577xxEA12x12OutputMode OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 4 }
|
|
wtWebio577xxEA12x12Alarm OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Device 5 }
|
|
|
|
-- wtWebio577xxEA12x12Basic Tree
|
|
|
|
wtWebio577xxEA12x12Network OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 1 }
|
|
wtWebio577xxEA12x12HTTP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 2 }
|
|
wtWebio577xxEA12x12Mail OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 3 }
|
|
wtWebio577xxEA12x12SNMP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 4 }
|
|
wtWebio577xxEA12x12UDP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 5 }
|
|
wtWebio577xxEA12x12Binary OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 6 }
|
|
wtWebio577xxEA12x12Syslog OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 7 }
|
|
wtWebio577xxEA12x12FTP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 8 }
|
|
wtWebio577xxEA12x12MQTT OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 12 }
|
|
wtWebio577xxEA12x12REST OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12Basic 13 }
|
|
|
|
-- wtWebio577xxEA12x12TimeDate Tree
|
|
|
|
wtWebio577xxEA12x12TimeZone OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12TimeDate 1 }
|
|
wtWebio577xxEA12x12TimeServer OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12TimeDate 2 }
|
|
wtWebio577xxEA12x12DeviceClock OBJECT IDENTIFIER ::= { wtWebio577xxEA12x12TimeDate 3 }
|
|
|
|
-- wtWebioEA12x12 Tree
|
|
|
|
wtWebioEA12x12InOut OBJECT IDENTIFIER ::= { wtWebioEA12x12 1 }
|
|
wtWebioEA12x12SessCntrl OBJECT IDENTIFIER ::= { wtWebioEA12x12 2 }
|
|
wtWebioEA12x12Config OBJECT IDENTIFIER ::= { wtWebioEA12x12 3 }
|
|
wtWebioEA12x12Diag OBJECT IDENTIFIER ::= { wtWebioEA12x12 4 }
|
|
|
|
-- wtWebioEA12x12Config Tree
|
|
|
|
wtWebioEA12x12Device OBJECT IDENTIFIER ::= { wtWebioEA12x12Config 1 }
|
|
wtWebioEA12x12Ports OBJECT IDENTIFIER ::= { wtWebioEA12x12Config 2 }
|
|
wtWebioEA12x12Manufact OBJECT IDENTIFIER ::= { wtWebioEA12x12Config 3 }
|
|
|
|
-- wtWebioEA12x12Device Tree
|
|
|
|
wtWebioEA12x12Text OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 1 }
|
|
wtWebioEA12x12TimeDate OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 2 }
|
|
wtWebioEA12x12Basic OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 3 }
|
|
wtWebioEA12x12OutputMode OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 4 }
|
|
wtWebioEA12x12Alarm OBJECT IDENTIFIER ::= { wtWebioEA12x12Device 5 }
|
|
|
|
-- wtWebioEA12x12Basic Tree
|
|
|
|
wtWebioEA12x12Network OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 1 }
|
|
wtWebioEA12x12HTTP OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 2 }
|
|
wtWebioEA12x12Mail OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 3 }
|
|
wtWebioEA12x12SNMP OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 4 }
|
|
wtWebioEA12x12UDP OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 5 }
|
|
wtWebioEA12x12Binary OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 6 }
|
|
wtWebioEA12x12Syslog OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 7 }
|
|
wtWebioEA12x12FTP OBJECT IDENTIFIER ::= { wtWebioEA12x12Basic 8 }
|
|
|
|
-- wtWebioEA12x12TimeDate Tree
|
|
|
|
wtWebioEA12x12TimeZone OBJECT IDENTIFIER ::= { wtWebioEA12x12TimeDate 1 }
|
|
wtWebioEA12x12TimeServer OBJECT IDENTIFIER ::= { wtWebioEA12x12TimeDate 2 }
|
|
wtWebioEA12x12DeviceClock OBJECT IDENTIFIER ::= { wtWebioEA12x12TimeDate 3 }
|
|
|
|
-- wtWebioEA24oem Tree
|
|
|
|
wtWebioEA24oemInOut OBJECT IDENTIFIER ::= { wtWebioEA24oem 1 }
|
|
wtWebioEA24oemSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA24oem 2 }
|
|
wtWebioEA24oemConfig OBJECT IDENTIFIER ::= { wtWebioEA24oem 3 }
|
|
wtWebioEA24oemDiag OBJECT IDENTIFIER ::= { wtWebioEA24oem 4 }
|
|
|
|
-- wtWebioEA24oemConfig Tree
|
|
|
|
wtWebioEA24oemDevice OBJECT IDENTIFIER ::= { wtWebioEA24oemConfig 1 }
|
|
wtWebioEA24oemPorts OBJECT IDENTIFIER ::= { wtWebioEA24oemConfig 2 }
|
|
wtWebioEA24oemManufact OBJECT IDENTIFIER ::= { wtWebioEA24oemConfig 3 }
|
|
|
|
-- wtWebioEA24oemDevice Tree
|
|
|
|
wtWebioEA24oemText OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 1 }
|
|
wtWebioEA24oemTimeDate OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 2 }
|
|
wtWebioEA24oemBasic OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 3 }
|
|
wtWebioEA24oemOutputMode OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 4 }
|
|
wtWebioEA24oemAlarm OBJECT IDENTIFIER ::= { wtWebioEA24oemDevice 5 }
|
|
|
|
-- wtWebioEA24oemBasic Tree
|
|
|
|
wtWebioEA24oemNetwork OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 1 }
|
|
wtWebioEA24oemHTTP OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 2 }
|
|
wtWebioEA24oemMail OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 3 }
|
|
wtWebioEA24oemSNMP OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 4 }
|
|
wtWebioEA24oemUDP OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 5 }
|
|
wtWebioEA24oemBinary OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 6 }
|
|
wtWebioEA24oemSyslog OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 7 }
|
|
wtWebioEA24oemFTP OBJECT IDENTIFIER ::= { wtWebioEA24oemBasic 8 }
|
|
|
|
-- wtWebioEA24oemTimeDate Tree
|
|
|
|
wtWebioEA24oemTimeZone OBJECT IDENTIFIER ::= { wtWebioEA24oemTimeDate 1 }
|
|
wtWebioEA24oemTimeServer OBJECT IDENTIFIER ::= { wtWebioEA24oemTimeDate 2 }
|
|
wtWebioEA24oemDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA24oemTimeDate 3 }
|
|
|
|
-- wtWebio577xxEA12x6Rel Tree
|
|
|
|
wtWebio577xxEA12x6RelInOut OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6Rel 1 }
|
|
wtWebio577xxEA12x6RelSessCntrl OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6Rel 2 }
|
|
wtWebio577xxEA12x6RelConfig OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6Rel 3 }
|
|
wtWebio577xxEA12x6RelDiag OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6Rel 4 }
|
|
|
|
-- wtWebio577xxEA12x6RelConfig Tree
|
|
|
|
wtWebio577xxEA12x6RelDevice OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelConfig 1 }
|
|
wtWebio577xxEA12x6RelPorts OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelConfig 2 }
|
|
wtWebio577xxEA12x6RelManufact OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelConfig 3 }
|
|
|
|
-- wtWebio577xxEA12x6RelDevice Tree
|
|
|
|
wtWebio577xxEA12x6RelText OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 1 }
|
|
wtWebio577xxEA12x6RelTimeDate OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 2 }
|
|
wtWebio577xxEA12x6RelBasic OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 3 }
|
|
wtWebio577xxEA12x6RelOutputMode OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 4 }
|
|
wtWebio577xxEA12x6RelAlarm OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelDevice 5 }
|
|
|
|
-- wtWebio577xxEA12x6RelBasic Tree
|
|
|
|
wtWebio577xxEA12x6RelNetwork OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 1 }
|
|
wtWebio577xxEA12x6RelHTTP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 2 }
|
|
wtWebio577xxEA12x6RelMail OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 3 }
|
|
wtWebio577xxEA12x6RelSNMP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 4 }
|
|
wtWebio577xxEA12x6RelUDP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 5 }
|
|
wtWebio577xxEA12x6RelBinary OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 6 }
|
|
wtWebio577xxEA12x6RelSyslog OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 7 }
|
|
wtWebio577xxEA12x6RelFTP OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 8 }
|
|
wtWebio577xxEA12x6RelMQTT OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 12 }
|
|
wtWebio577xxEA12x6RelREST OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelBasic 13 }
|
|
|
|
-- wtWebio577xxEA12x6RelTimeDate Tree
|
|
|
|
wtWebio577xxEA12x6RelTimeZone OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelTimeDate 1 }
|
|
wtWebio577xxEA12x6RelTimeServer OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelTimeDate 2 }
|
|
wtWebio577xxEA12x6RelDeviceClock OBJECT IDENTIFIER ::= { wtWebio577xxEA12x6RelTimeDate 3 }
|
|
|
|
-- wtWebioEA12x6Rel Tree
|
|
|
|
wtWebioEA12x6RelInOut OBJECT IDENTIFIER ::= { wtWebioEA12x6Rel 1 }
|
|
wtWebioEA12x6RelSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA12x6Rel 2 }
|
|
wtWebioEA12x6RelConfig OBJECT IDENTIFIER ::= { wtWebioEA12x6Rel 3 }
|
|
wtWebioEA12x6RelDiag OBJECT IDENTIFIER ::= { wtWebioEA12x6Rel 4 }
|
|
|
|
-- wtWebioEA12x6RelConfig Tree
|
|
|
|
wtWebioEA12x6RelDevice OBJECT IDENTIFIER ::= { wtWebioEA12x6RelConfig 1 }
|
|
wtWebioEA12x6RelPorts OBJECT IDENTIFIER ::= { wtWebioEA12x6RelConfig 2 }
|
|
wtWebioEA12x6RelManufact OBJECT IDENTIFIER ::= { wtWebioEA12x6RelConfig 3 }
|
|
|
|
-- wtWebioEA12x6RelDevice Tree
|
|
|
|
wtWebioEA12x6RelText OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 1 }
|
|
wtWebioEA12x6RelTimeDate OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 2 }
|
|
wtWebioEA12x6RelBasic OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 3 }
|
|
wtWebioEA12x6RelOutputMode OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 4 }
|
|
wtWebioEA12x6RelAlarm OBJECT IDENTIFIER ::= { wtWebioEA12x6RelDevice 5 }
|
|
|
|
-- wtWebioEA12x6RelBasic Tree
|
|
|
|
wtWebioEA12x6RelNetwork OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 1 }
|
|
wtWebioEA12x6RelHTTP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 2 }
|
|
wtWebioEA12x6RelMail OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 3 }
|
|
wtWebioEA12x6RelSNMP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 4 }
|
|
wtWebioEA12x6RelUDP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 5 }
|
|
wtWebioEA12x6RelBinary OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 6 }
|
|
wtWebioEA12x6RelSyslog OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 7 }
|
|
wtWebioEA12x6RelFTP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelBasic 8 }
|
|
|
|
-- wtWebioEA12x6RelTimeDate Tree
|
|
|
|
wtWebioEA12x6RelTimeZone OBJECT IDENTIFIER ::= { wtWebioEA12x6RelTimeDate 1 }
|
|
wtWebioEA12x6RelTimeServer OBJECT IDENTIFIER ::= { wtWebioEA12x6RelTimeDate 2 }
|
|
wtWebioEA12x6RelDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA12x6RelTimeDate 3 }
|
|
|
|
-- wtWebAlarm6x6 Tree
|
|
|
|
wtWebAlarm6x6InOut OBJECT IDENTIFIER ::= { wtWebAlarm6x6 1 }
|
|
wtWebAlarm6x6SessCntrl OBJECT IDENTIFIER ::= { wtWebAlarm6x6 2 }
|
|
wtWebAlarm6x6Config OBJECT IDENTIFIER ::= { wtWebAlarm6x6 3 }
|
|
wtWebAlarm6x6Diag OBJECT IDENTIFIER ::= { wtWebAlarm6x6 4 }
|
|
|
|
-- wtWebAlarm6x6Config Tree
|
|
|
|
wtWebAlarm6x6Device OBJECT IDENTIFIER ::= { wtWebAlarm6x6Config 1 }
|
|
wtWebAlarm6x6Ports OBJECT IDENTIFIER ::= { wtWebAlarm6x6Config 2 }
|
|
wtWebAlarm6x6Manufact OBJECT IDENTIFIER ::= { wtWebAlarm6x6Config 3 }
|
|
|
|
-- wtWebAlarm6x6Device Tree
|
|
|
|
wtWebAlarm6x6Text OBJECT IDENTIFIER ::= { wtWebAlarm6x6Device 1 }
|
|
wtWebAlarm6x6TimeDate OBJECT IDENTIFIER ::= { wtWebAlarm6x6Device 2 }
|
|
wtWebAlarm6x6Basic OBJECT IDENTIFIER ::= { wtWebAlarm6x6Device 3 }
|
|
wtWebAlarm6x6Alarm OBJECT IDENTIFIER ::= { wtWebAlarm6x6Device 5 }
|
|
|
|
-- wtWebAlarm6x6Basic Tree
|
|
|
|
wtWebAlarm6x6Network OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 1 }
|
|
wtWebAlarm6x6HTTP OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 2 }
|
|
wtWebAlarm6x6Mail OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 3 }
|
|
wtWebAlarm6x6SNMP OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 4 }
|
|
wtWebAlarm6x6UDP OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 5 }
|
|
wtWebAlarm6x6Syslog OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 7 }
|
|
wtWebAlarm6x6FTP OBJECT IDENTIFIER ::= { wtWebAlarm6x6Basic 8 }
|
|
|
|
-- wtWebAlarm6x6TimeDate Tree
|
|
|
|
wtWebAlarm6x6TimeZone OBJECT IDENTIFIER ::= { wtWebAlarm6x6TimeDate 1 }
|
|
wtWebAlarm6x6TimeServer OBJECT IDENTIFIER ::= { wtWebAlarm6x6TimeDate 2 }
|
|
wtWebAlarm6x6DeviceClock OBJECT IDENTIFIER ::= { wtWebAlarm6x6TimeDate 3 }
|
|
|
|
-- wtWebCount6 Tree
|
|
|
|
wtWebCount6InOut OBJECT IDENTIFIER ::= { wtWebCount6 1 }
|
|
wtWebCount6SessCntrl OBJECT IDENTIFIER ::= { wtWebCount6 2 }
|
|
wtWebCount6Config OBJECT IDENTIFIER ::= { wtWebCount6 3 }
|
|
wtWebCount6Diag OBJECT IDENTIFIER ::= { wtWebCount6 4 }
|
|
|
|
-- wtWebCount6Config Tree
|
|
|
|
wtWebCount6Device OBJECT IDENTIFIER ::= { wtWebCount6Config 1 }
|
|
wtWebCount6Ports OBJECT IDENTIFIER ::= { wtWebCount6Config 2 }
|
|
wtWebCount6Manufact OBJECT IDENTIFIER ::= { wtWebCount6Config 3 }
|
|
|
|
-- wtWebCount6Device Tree
|
|
|
|
wtWebCount6Text OBJECT IDENTIFIER ::= { wtWebCount6Device 1 }
|
|
wtWebCount6TimeDate OBJECT IDENTIFIER ::= { wtWebCount6Device 2 }
|
|
wtWebCount6Basic OBJECT IDENTIFIER ::= { wtWebCount6Device 3 }
|
|
wtWebCount6Report OBJECT IDENTIFIER ::= { wtWebCount6Device 5 }
|
|
|
|
-- wtWebCount6Basic Tree
|
|
|
|
wtWebCount6Network OBJECT IDENTIFIER ::= { wtWebCount6Basic 1 }
|
|
wtWebCount6HTTP OBJECT IDENTIFIER ::= { wtWebCount6Basic 2 }
|
|
wtWebCount6Mail OBJECT IDENTIFIER ::= { wtWebCount6Basic 3 }
|
|
wtWebCount6SNMP OBJECT IDENTIFIER ::= { wtWebCount6Basic 4 }
|
|
wtWebCount6UDP OBJECT IDENTIFIER ::= { wtWebCount6Basic 5 }
|
|
wtWebCount6Syslog OBJECT IDENTIFIER ::= { wtWebCount6Basic 7 }
|
|
wtWebCount6FTP OBJECT IDENTIFIER ::= { wtWebCount6Basic 8 }
|
|
|
|
-- wtWebCount6TimeDate Tree
|
|
|
|
wtWebCount6TimeZone OBJECT IDENTIFIER ::= { wtWebCount6TimeDate 1 }
|
|
wtWebCount6TimeServer OBJECT IDENTIFIER ::= { wtWebCount6TimeDate 2 }
|
|
wtWebCount6DeviceClock OBJECT IDENTIFIER ::= { wtWebCount6TimeDate 3 }
|
|
|
|
-- wtWebioEA6x6 Tree
|
|
|
|
wtWebioEA6x6InOut OBJECT IDENTIFIER ::= { wtWebioEA6x6 1 }
|
|
wtWebioEA6x6SessCntrl OBJECT IDENTIFIER ::= { wtWebioEA6x6 2 }
|
|
wtWebioEA6x6Config OBJECT IDENTIFIER ::= { wtWebioEA6x6 3 }
|
|
wtWebioEA6x6Diag OBJECT IDENTIFIER ::= { wtWebioEA6x6 4 }
|
|
|
|
-- wtWebioEA6x6Config Tree
|
|
|
|
wtWebioEA6x6Device OBJECT IDENTIFIER ::= { wtWebioEA6x6Config 1 }
|
|
wtWebioEA6x6Ports OBJECT IDENTIFIER ::= { wtWebioEA6x6Config 2 }
|
|
wtWebioEA6x6Manufact OBJECT IDENTIFIER ::= { wtWebioEA6x6Config 3 }
|
|
|
|
-- wtWebioEA6x6Device Tree
|
|
|
|
wtWebioEA6x6Text OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 1 }
|
|
wtWebioEA6x6TimeDate OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 2 }
|
|
wtWebioEA6x6Basic OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 3 }
|
|
wtWebioEA6x6OutputMode OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 4 }
|
|
wtWebioEA6x6Alarm OBJECT IDENTIFIER ::= { wtWebioEA6x6Device 5 }
|
|
|
|
-- wtWebioEA6x6Basic Tree
|
|
|
|
wtWebioEA6x6Network OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 1 }
|
|
wtWebioEA6x6HTTP OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 2 }
|
|
wtWebioEA6x6Mail OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 3 }
|
|
wtWebioEA6x6SNMP OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 4 }
|
|
wtWebioEA6x6UDP OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 5 }
|
|
wtWebioEA6x6Binary OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 6 }
|
|
wtWebioEA6x6Syslog OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 7 }
|
|
wtWebioEA6x6FTP OBJECT IDENTIFIER ::= { wtWebioEA6x6Basic 8 }
|
|
|
|
-- wtWebioEA6x6TimeDate Tree
|
|
|
|
wtWebioEA6x6TimeZone OBJECT IDENTIFIER ::= { wtWebioEA6x6TimeDate 1 }
|
|
wtWebioEA6x6TimeServer OBJECT IDENTIFIER ::= { wtWebioEA6x6TimeDate 2 }
|
|
wtWebioEA6x6DeviceClock OBJECT IDENTIFIER ::= { wtWebioEA6x6TimeDate 3 }
|
|
|
|
-- wtWebioEA2x2ERP Tree
|
|
|
|
wtWebioEA2x2ERPInOut OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP 1 }
|
|
wtWebioEA2x2ERPSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP 2 }
|
|
wtWebioEA2x2ERPConfig OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP 3 }
|
|
wtWebioEA2x2ERPDiag OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP 4 }
|
|
|
|
-- wtWebioEA2x2ERPConfig Tree
|
|
|
|
wtWebioEA2x2ERPDevice OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPConfig 1 }
|
|
wtWebioEA2x2ERPPorts OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPConfig 2 }
|
|
wtWebioEA2x2ERPManufact OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPConfig 3 }
|
|
|
|
-- wtWebioEA2x2ERPDevice Tree
|
|
|
|
wtWebioEA2x2ERPText OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 1 }
|
|
wtWebioEA2x2ERPTimeDate OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 2 }
|
|
wtWebioEA2x2ERPBasic OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 3 }
|
|
wtWebioEA2x2ERPOutputMode OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 4 }
|
|
wtWebioEA2x2ERPAlarm OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPDevice 5 }
|
|
|
|
-- wtWebioEA2x2ERPBasic Tree
|
|
|
|
wtWebioEA2x2ERPNetwork OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 1 }
|
|
wtWebioEA2x2ERPHTTP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 2 }
|
|
wtWebioEA2x2ERPMail OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 3 }
|
|
wtWebioEA2x2ERPSNMP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 4 }
|
|
wtWebioEA2x2ERPUDP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 5 }
|
|
wtWebioEA2x2ERPBinary OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 6 }
|
|
wtWebioEA2x2ERPSyslog OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 7 }
|
|
wtWebioEA2x2ERPFTP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 8 }
|
|
wtWebioEA2x2ERPWayBack OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPBasic 10 }
|
|
|
|
-- wtWebioEA2x2ERPTimeDate Tree
|
|
|
|
wtWebioEA2x2ERPTimeZone OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPTimeDate 1 }
|
|
wtWebioEA2x2ERPTimeServer OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPTimeDate 2 }
|
|
wtWebioEA2x2ERPDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA2x2ERPTimeDate 3 }
|
|
|
|
-- wtWebioEA12x6RelERP Tree
|
|
|
|
wtWebioEA12x6RelERPInOut OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERP 1 }
|
|
wtWebioEA12x6RelERPSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERP 2 }
|
|
wtWebioEA12x6RelERPConfig OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERP 3 }
|
|
wtWebioEA12x6RelERPDiag OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERP 4 }
|
|
|
|
-- wtWebioEA12x6RelERPConfig Tree
|
|
|
|
wtWebioEA12x6RelERPDevice OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPConfig 1 }
|
|
wtWebioEA12x6RelERPPorts OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPConfig 2 }
|
|
wtWebioEA12x6RelERPManufact OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPConfig 3 }
|
|
|
|
-- wtWebioEA12x6RelERPDevice Tree
|
|
|
|
wtWebioEA12x6RelERPText OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 1 }
|
|
wtWebioEA12x6RelERPTimeDate OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 2 }
|
|
wtWebioEA12x6RelERPBasic OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 3 }
|
|
wtWebioEA12x6RelERPOutputMode OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 4 }
|
|
wtWebioEA12x6RelERPAlarm OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPDevice 5 }
|
|
|
|
-- wtWebioEA12x6RelERPBasic Tree
|
|
|
|
wtWebioEA12x6RelERPNetwork OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 1 }
|
|
wtWebioEA12x6RelERPHTTP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 2 }
|
|
wtWebioEA12x6RelERPMail OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 3 }
|
|
wtWebioEA12x6RelERPSNMP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 4 }
|
|
wtWebioEA12x6RelERPUDP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 5 }
|
|
wtWebioEA12x6RelERPBinary OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 6 }
|
|
wtWebioEA12x6RelERPSyslog OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 7 }
|
|
wtWebioEA12x6RelERPFTP OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 8 }
|
|
wtWebioEA12x6RelERPWayBack OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPBasic 10 }
|
|
|
|
-- wtWebioEA12x6RelERPTimeDate Tree
|
|
|
|
wtWebioEA12x6RelERPTimeZone OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPTimeDate 1 }
|
|
wtWebioEA12x6RelERPTimeServer OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPTimeDate 2 }
|
|
wtWebioEA12x6RelERPDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA12x6RelERPTimeDate 3 }
|
|
|
|
-- wtIpWatcher Tree
|
|
|
|
wtIpWatcherInOut OBJECT IDENTIFIER ::= { wtIpWatcher 1 }
|
|
wtIpWatcherSessCntrl OBJECT IDENTIFIER ::= { wtIpWatcher 2 }
|
|
wtIpWatcherConfig OBJECT IDENTIFIER ::= { wtIpWatcher 3 }
|
|
wtIpWatcherDiag OBJECT IDENTIFIER ::= { wtIpWatcher 4 }
|
|
|
|
-- wtIpWatcherConfig Tree
|
|
|
|
wtIpWatcherDevice OBJECT IDENTIFIER ::= { wtIpWatcherConfig 1 }
|
|
wtIpWatcherPorts OBJECT IDENTIFIER ::= { wtIpWatcherConfig 2 }
|
|
wtIpWatcherManufact OBJECT IDENTIFIER ::= { wtIpWatcherConfig 3 }
|
|
|
|
-- wtIpWatcherDevice Tree
|
|
|
|
wtIpWatcherText OBJECT IDENTIFIER ::= { wtIpWatcherDevice 1 }
|
|
wtIpWatcherTimeDate OBJECT IDENTIFIER ::= { wtIpWatcherDevice 2 }
|
|
wtIpWatcherBasic OBJECT IDENTIFIER ::= { wtIpWatcherDevice 3 }
|
|
wtIpWatcherAlarm OBJECT IDENTIFIER ::= { wtIpWatcherDevice 5 }
|
|
|
|
-- wtIpWatcherBasic Tree
|
|
|
|
wtIpWatcherNetwork OBJECT IDENTIFIER ::= { wtIpWatcherBasic 1 }
|
|
wtIpWatcherHTTP OBJECT IDENTIFIER ::= { wtIpWatcherBasic 2 }
|
|
wtIpWatcherMail OBJECT IDENTIFIER ::= { wtIpWatcherBasic 3 }
|
|
wtIpWatcherSNMP OBJECT IDENTIFIER ::= { wtIpWatcherBasic 4 }
|
|
wtIpWatcherUDP OBJECT IDENTIFIER ::= { wtIpWatcherBasic 5 }
|
|
wtIpWatcherSyslog OBJECT IDENTIFIER ::= { wtIpWatcherBasic 7 }
|
|
wtIpWatcherFTP OBJECT IDENTIFIER ::= { wtIpWatcherBasic 8 }
|
|
wtIpWatcherIpList OBJECT IDENTIFIER ::= { wtIpWatcherBasic 11 }
|
|
|
|
-- wtIpWatcherTimeDate Tree
|
|
|
|
wtIpWatcherTimeZone OBJECT IDENTIFIER ::= { wtIpWatcherTimeDate 1 }
|
|
wtIpWatcherTimeServer OBJECT IDENTIFIER ::= { wtIpWatcherTimeDate 2 }
|
|
wtIpWatcherDeviceClock OBJECT IDENTIFIER ::= { wtIpWatcherTimeDate 3 }
|
|
|
|
-- wtWebioEA2x2-24V Tree
|
|
|
|
wtWebioEA2x2-24VInOut OBJECT IDENTIFIER ::= { wtWebioEA2x2-24V 1 }
|
|
wtWebioEA2x2-24VSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA2x2-24V 2 }
|
|
wtWebioEA2x2-24VConfig OBJECT IDENTIFIER ::= { wtWebioEA2x2-24V 3 }
|
|
wtWebioEA2x2-24VDiag OBJECT IDENTIFIER ::= { wtWebioEA2x2-24V 4 }
|
|
|
|
-- wtWebioEA2x2-24VConfig Tree
|
|
|
|
wtWebioEA2x2-24VDevice OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VConfig 1 }
|
|
wtWebioEA2x2-24VPorts OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VConfig 2 }
|
|
wtWebioEA2x2-24VManufact OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VConfig 3 }
|
|
|
|
-- wtWebioEA2x2-24VDevice Tree
|
|
|
|
wtWebioEA2x2-24VText OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 1 }
|
|
wtWebioEA2x2-24VTimeDate OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 2 }
|
|
wtWebioEA2x2-24VBasic OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 3 }
|
|
wtWebioEA2x2-24VOutputMode OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 4 }
|
|
wtWebioEA2x2-24VAlarm OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VDevice 5 }
|
|
|
|
-- wtWebioEA2x2-24VBasic Tree
|
|
|
|
wtWebioEA2x2-24VNetwork OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 1 }
|
|
wtWebioEA2x2-24VHTTP OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 2 }
|
|
wtWebioEA2x2-24VMail OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 3 }
|
|
wtWebioEA2x2-24VSNMP OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 4 }
|
|
wtWebioEA2x2-24VUDP OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 5 }
|
|
wtWebioEA2x2-24VBinary OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 6 }
|
|
wtWebioEA2x2-24VSyslog OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 7 }
|
|
wtWebioEA2x2-24VFTP OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VBasic 8 }
|
|
|
|
-- wtWebioEA2x2-24VTimeDate Tree
|
|
|
|
wtWebioEA2x2-24VTimeZone OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VTimeDate 1 }
|
|
wtWebioEA2x2-24VTimeServer OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VTimeDate 2 }
|
|
wtWebioEA2x2-24VDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA2x2-24VTimeDate 3 }
|
|
|
|
-- wtWebioEA2x2ERP-24V Tree
|
|
|
|
wtWebioEA2x2ERP-24VInOut OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24V 1 }
|
|
wtWebioEA2x2ERP-24VSessCntrl OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24V 2 }
|
|
wtWebioEA2x2ERP-24VConfig OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24V 3 }
|
|
wtWebioEA2x2ERP-24VDiag OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24V 4 }
|
|
|
|
-- wtWebioEA2x2ERP-24VConfig Tree
|
|
|
|
wtWebioEA2x2ERP-24VDevice OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VConfig 1 }
|
|
wtWebioEA2x2ERP-24VPorts OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VConfig 2 }
|
|
wtWebioEA2x2ERP-24VManufact OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VConfig 3 }
|
|
|
|
-- wtWebioEA2x2ERP-24VDevice Tree
|
|
|
|
wtWebioEA2x2ERP-24VText OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 1 }
|
|
wtWebioEA2x2ERP-24VTimeDate OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 2 }
|
|
wtWebioEA2x2ERP-24VBasic OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 3 }
|
|
wtWebioEA2x2ERP-24VOutputMode OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 4 }
|
|
wtWebioEA2x2ERP-24VAlarm OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VDevice 5 }
|
|
|
|
-- wtWebioEA2x2ERP-24VBasic Tree
|
|
|
|
wtWebioEA2x2ERP-24VNetwork OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 1 }
|
|
wtWebioEA2x2ERP-24VHTTP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 2 }
|
|
wtWebioEA2x2ERP-24VMail OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 3 }
|
|
wtWebioEA2x2ERP-24VSNMP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 4 }
|
|
wtWebioEA2x2ERP-24VUDP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 5 }
|
|
wtWebioEA2x2ERP-24VBinary OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 6 }
|
|
wtWebioEA2x2ERP-24VSyslog OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 7 }
|
|
wtWebioEA2x2ERP-24VFTP OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 8 }
|
|
wtWebioEA2x2ERP-24VWayBack OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VBasic 10 }
|
|
|
|
-- wtWebioEA2x2ERP-24VTimeDate Tree
|
|
|
|
wtWebioEA2x2ERP-24VTimeZone OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VTimeDate 1 }
|
|
wtWebioEA2x2ERP-24VTimeServer OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VTimeDate 2 }
|
|
wtWebioEA2x2ERP-24VDeviceClock OBJECT IDENTIFIER ::= { wtWebioEA2x2ERP-24VTimeDate 3 }
|
|
|
|
|
|
-- wtIpWatcher-24V Tree
|
|
|
|
wtIpWatcher-24VInOut OBJECT IDENTIFIER ::= { wtIpWatcher-24V 1 }
|
|
wtIpWatcher-24VSessCntrl OBJECT IDENTIFIER ::= { wtIpWatcher-24V 2 }
|
|
wtIpWatcher-24VConfig OBJECT IDENTIFIER ::= { wtIpWatcher-24V 3 }
|
|
wtIpWatcher-24VDiag OBJECT IDENTIFIER ::= { wtIpWatcher-24V 4 }
|
|
|
|
-- wtIpWatcher-24VConfig Tree
|
|
|
|
wtIpWatcher-24VDevice OBJECT IDENTIFIER ::= { wtIpWatcher-24VConfig 1 }
|
|
wtIpWatcher-24VPorts OBJECT IDENTIFIER ::= { wtIpWatcher-24VConfig 2 }
|
|
wtIpWatcher-24VManufact OBJECT IDENTIFIER ::= { wtIpWatcher-24VConfig 3 }
|
|
|
|
-- wtIpWatcher-24VDevice Tree
|
|
|
|
wtIpWatcher-24VText OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 1 }
|
|
wtIpWatcher-24VTimeDate OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 2 }
|
|
wtIpWatcher-24VBasic OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 3 }
|
|
wtIpWatcher-24VOutputMode OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 4 }
|
|
wtIpWatcher-24VAlarm OBJECT IDENTIFIER ::= { wtIpWatcher-24VDevice 5 }
|
|
|
|
-- wtIpWatcher-24VBasic Tree
|
|
|
|
wtIpWatcher-24VNetwork OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 1 }
|
|
wtIpWatcher-24VHTTP OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 2 }
|
|
wtIpWatcher-24VMail OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 3 }
|
|
wtIpWatcher-24VSNMP OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 4 }
|
|
wtIpWatcher-24VUDP OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 5 }
|
|
wtIpWatcher-24VSyslog OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 7 }
|
|
wtIpWatcher-24VFTP OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 8 }
|
|
wtIpWatcher-24VIpList OBJECT IDENTIFIER ::= { wtIpWatcher-24VBasic 11 }
|
|
|
|
-- wtIpWatcher-24VTimeDate Tree
|
|
|
|
wtIpWatcher-24VTimeZone OBJECT IDENTIFIER ::= { wtIpWatcher-24VTimeDate 1 }
|
|
wtIpWatcher-24VTimeServer OBJECT IDENTIFIER ::= { wtIpWatcher-24VTimeDate 2 }
|
|
wtIpWatcher-24VDeviceClock OBJECT IDENTIFIER ::= { wtIpWatcher-24VTimeDate 3 }
|
|
|
|
|
|
-- wtTrapReceiver2x2 Tree
|
|
|
|
wtTrapReceiver2x2InOut OBJECT IDENTIFIER ::= { wtTrapReceiver2x2 1 }
|
|
wtTrapReceiver2x2SessCntrl OBJECT IDENTIFIER ::= { wtTrapReceiver2x2 2 }
|
|
wtTrapReceiver2x2Config OBJECT IDENTIFIER ::= { wtTrapReceiver2x2 3 }
|
|
wtTrapReceiver2x2Diag OBJECT IDENTIFIER ::= { wtTrapReceiver2x2 4 }
|
|
|
|
-- wtTrapReceiver2x2Config Tree
|
|
|
|
wtTrapReceiver2x2Device OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Config 1 }
|
|
wtTrapReceiver2x2Ports OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Config 2 }
|
|
wtTrapReceiver2x2Manufact OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Config 3 }
|
|
|
|
-- wtTrapReceiver2x2Device Tree
|
|
|
|
wtTrapReceiver2x2Text OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 1 }
|
|
wtTrapReceiver2x2TimeDate OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 2 }
|
|
wtTrapReceiver2x2Basic OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 3 }
|
|
wtTrapReceiver2x2OutputMode OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 4 }
|
|
wtTrapReceiver2x2Action OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 5 }
|
|
wtTrapReceiver2x2PrepareInEvents OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 6 }
|
|
wtTrapReceiver2x2PrepareOutEvents OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Device 7 }
|
|
|
|
|
|
-- wtTrapReceiver2x2Basic Tree
|
|
|
|
wtTrapReceiver2x2Network OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 1 }
|
|
wtTrapReceiver2x2HTTP OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 2 }
|
|
wtTrapReceiver2x2Mail OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 3 }
|
|
wtTrapReceiver2x2SNMP OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 4 }
|
|
wtTrapReceiver2x2UDP OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 5 }
|
|
wtTrapReceiver2x2Syslog OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 7 }
|
|
wtTrapReceiver2x2FTP OBJECT IDENTIFIER ::= { wtTrapReceiver2x2Basic 8 }
|
|
|
|
-- wtTrapReceiver2x2TimeDate Tree
|
|
|
|
wtTrapReceiver2x2TimeZone OBJECT IDENTIFIER ::= { wtTrapReceiver2x2TimeDate 1 }
|
|
wtTrapReceiver2x2TimeServer OBJECT IDENTIFIER ::= { wtTrapReceiver2x2TimeDate 2 }
|
|
wtTrapReceiver2x2DeviceClock OBJECT IDENTIFIER ::= { wtTrapReceiver2x2TimeDate 3 }
|
|
|
|
-- wtTrapReceiver2x2PrepareInEvents
|
|
wtTrapReceiver2x2WatchList OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareInEvents 1 }
|
|
wtTrapReceiver2x2InEvSystemTimer OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareInEvents 2 }
|
|
wtTrapReceiver2x2InEvButtons OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareInEvents 3 }
|
|
wtTrapReceiver2x2InEvInputs OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareInEvents 4 }
|
|
|
|
-- wtTrapReceiver2x2PrepareOutEvents
|
|
wtTrapReceiver2x2OutEvOutputs OBJECT IDENTIFIER ::= { wtTrapReceiver2x2PrepareOutEvents 1 }
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebio577xxEA1x1InOut Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA1x1Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebio577xxEA1x1InOut 1 }
|
|
|
|
wtWebio577xxEA1x1Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebio577xxEA1x1InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebio577xxEA1x1InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebio577xxEA1x1InOut 3 }
|
|
|
|
wtWebio577xxEA1x1InputEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebio577xxEA1x1InputNo }
|
|
::= { wtWebio577xxEA1x1InputTable 1 }
|
|
|
|
WtWebio577xxEA1x1InputEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1InputNo INTEGER,
|
|
wtWebio577xxEA1x1InputCounter INTEGER,
|
|
wtWebio577xxEA1x1InputCounterClear INTEGER,
|
|
wtWebio577xxEA1x1InputState INTEGER
|
|
|
|
}
|
|
|
|
wtWebio577xxEA1x1InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebio577xxEA1x1InputEntry 1 }
|
|
|
|
wtWebio577xxEA1x1InputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebio577xxEA1x1InputEntry 2 }
|
|
|
|
wtWebio577xxEA1x1InputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebio577xxEA1x1InputEntry 3 }
|
|
|
|
wtWebio577xxEA1x1InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebio577xxEA1x1InputEntry 4 }
|
|
|
|
wtWebio577xxEA1x1InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtWebio577xxEA1x1InOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebio577xxEA1x1OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebio577xxEA1x1InOut 5 }
|
|
|
|
wtWebio577xxEA1x1OutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebio577xxEA1x1OutputNo }
|
|
::= { wtWebio577xxEA1x1OutputTable 1 }
|
|
|
|
WtWebio577xxEA1x1OutputEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1OutputNo INTEGER,
|
|
wtWebio577xxEA1x1OutputState INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA1x1OutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebio577xxEA1x1OutputEntry 1 }
|
|
|
|
wtWebio577xxEA1x1OutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebio577xxEA1x1OutputEntry 2 }
|
|
|
|
|
|
wtWebio577xxEA1x1OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtWebio577xxEA1x1InOut 6 }
|
|
|
|
wtWebio577xxEA1x1SetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1"
|
|
::= { wtWebio577xxEA1x1InOut 7 }
|
|
|
|
-- wtWebio577xxEA1x1SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebio577xxEA1x1SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebio577xxEA1x1SessCntrl 1 }
|
|
|
|
wtWebio577xxEA1x1SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebio577xxEA1x1SessCntrl 2 }
|
|
|
|
wtWebio577xxEA1x1SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebio577xxEA1x1SessCntrl 3 }
|
|
|
|
wtWebio577xxEA1x1SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebio577xxEA1x1SessCntrl 4 }
|
|
|
|
wtWebio577xxEA1x1SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebio577xxEA1x1SessCntrl 5 }
|
|
|
|
-- wtWebio577xxEA1x1Text Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA1x1DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA1x1Text 1 }
|
|
|
|
wtWebio577xxEA1x1DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA1x1Text 2 }
|
|
|
|
wtWebio577xxEA1x1DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA1x1Text 3 }
|
|
|
|
wtWebio577xxEA1x1DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA1x1Text 4 }
|
|
|
|
-- wtWebio577xxEA1x1TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA1x1TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebio577xxEA1x1TimeZone 1 }
|
|
|
|
wtWebio577xxEA1x1TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebio577xxEA1x1TimeZone 2 }
|
|
|
|
wtWebio577xxEA1x1TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebio577xxEA1x1TimeZone 3 }
|
|
|
|
wtWebio577xxEA1x1StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebio577xxEA1x1TimeZone 4 }
|
|
|
|
wtWebio577xxEA1x1StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebio577xxEA1x1TimeZone 5 }
|
|
|
|
wtWebio577xxEA1x1StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebio577xxEA1x1TimeZone 6 }
|
|
|
|
wtWebio577xxEA1x1StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA1x1StartMonth-January(1),
|
|
wtWebio577xxEA1x1StartMonth-February(2),
|
|
wtWebio577xxEA1x1StartMonth-March(3),
|
|
wtWebio577xxEA1x1StartMonth-April(4),
|
|
wtWebio577xxEA1x1StartMonth-May(5),
|
|
wtWebio577xxEA1x1StartMonth-June(6),
|
|
wtWebio577xxEA1x1StartMonth-July(7),
|
|
wtWebio577xxEA1x1StartMonth-August(8),
|
|
wtWebio577xxEA1x1StartMonth-September(9),
|
|
wtWebio577xxEA1x1StartMonth-October(10),
|
|
wtWebio577xxEA1x1StartMonth-November(11),
|
|
wtWebio577xxEA1x1StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebio577xxEA1x1TimeZone 7 }
|
|
|
|
wtWebio577xxEA1x1StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA1x1StartMode-first(1),
|
|
wtWebio577xxEA1x1StartMode-second(2),
|
|
wtWebio577xxEA1x1StartMode-third(3),
|
|
wtWebio577xxEA1x1StartMode-fourth(4),
|
|
wtWebio577xxEA1x1StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebio577xxEA1x1TimeZone 8 }
|
|
|
|
wtWebio577xxEA1x1StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA1x1StartWday-Sunday(1),
|
|
wtWebio577xxEA1x1StartWday-Monday(2),
|
|
wtWebio577xxEA1x1StartWday-Tuesday(3),
|
|
wtWebio577xxEA1x1StartWday-Thursday(4),
|
|
wtWebio577xxEA1x1StartWday-Wednesday(5),
|
|
wtWebio577xxEA1x1StartWday-Friday(6),
|
|
wtWebio577xxEA1x1StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebio577xxEA1x1TimeZone 9 }
|
|
|
|
wtWebio577xxEA1x1StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA1x1TimeZone 10 }
|
|
|
|
wtWebio577xxEA1x1StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA1x1TimeZone 11 }
|
|
|
|
wtWebio577xxEA1x1StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA1x1StopMonth-January(1),
|
|
wtWebio577xxEA1x1StopMonth-February(2),
|
|
wtWebio577xxEA1x1StopMonth-March(3),
|
|
wtWebio577xxEA1x1StopMonth-April(4),
|
|
wtWebio577xxEA1x1StopMonth-May(5),
|
|
wtWebio577xxEA1x1StopMonth-June(6),
|
|
wtWebio577xxEA1x1StopMonth-July(7),
|
|
wtWebio577xxEA1x1StopMonth-August(8),
|
|
wtWebio577xxEA1x1StopMonth-September(9),
|
|
wtWebio577xxEA1x1StopMonth-October(10),
|
|
wtWebio577xxEA1x1StopMonth-November(11),
|
|
wtWebio577xxEA1x1StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA1x1TimeZone 12 }
|
|
|
|
wtWebio577xxEA1x1StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA1x1StopMode-first(1),
|
|
wtWebio577xxEA1x1StopMode-second(2),
|
|
wtWebio577xxEA1x1StopMode-third(3),
|
|
wtWebio577xxEA1x1StopMode-fourth(4),
|
|
wtWebio577xxEA1x1StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA1x1TimeZone 13 }
|
|
|
|
wtWebio577xxEA1x1StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA1x1StopWday-Sunday(1),
|
|
wtWebio577xxEA1x1StopWday-Monday(2),
|
|
wtWebio577xxEA1x1StopWday-Tuesday(3),
|
|
wtWebio577xxEA1x1StopWday-Thursday(4),
|
|
wtWebio577xxEA1x1StopWday-Wednesday(5),
|
|
wtWebio577xxEA1x1StopWday-Friday(6),
|
|
wtWebio577xxEA1x1StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA1x1TimeZone 14 }
|
|
|
|
wtWebio577xxEA1x1StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA1x1TimeZone 15 }
|
|
|
|
wtWebio577xxEA1x1StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA1x1TimeZone 16 }
|
|
|
|
-- wtWebio577xxEA1x1TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA1x1TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebio577xxEA1x1TimeServer 1 }
|
|
|
|
wtWebio577xxEA1x1TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebio577xxEA1x1TimeServer 2 }
|
|
|
|
wtWebio577xxEA1x1TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebio577xxEA1x1TimeServer 3 }
|
|
|
|
wtWebio577xxEA1x1TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebio577xxEA1x1TimeServer 4 }
|
|
|
|
|
|
-- wtWebio577xxEA1x1DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA1x1ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebio577xxEA1x1DeviceClock 1 }
|
|
|
|
wtWebio577xxEA1x1ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebio577xxEA1x1DeviceClock 2 }
|
|
|
|
wtWebio577xxEA1x1ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA1x1DeviceClock 3 }
|
|
|
|
wtWebio577xxEA1x1ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA1x1ClockMonth-January(1),
|
|
wtWebio577xxEA1x1ClockMonth-February(2),
|
|
wtWebio577xxEA1x1ClockMonth-March(3),
|
|
wtWebio577xxEA1x1ClockMonth-April(4),
|
|
wtWebio577xxEA1x1ClockMonth-May(5),
|
|
wtWebio577xxEA1x1ClockMonth-June(6),
|
|
wtWebio577xxEA1x1ClockMonth-July(7),
|
|
wtWebio577xxEA1x1ClockMonth-August(8),
|
|
wtWebio577xxEA1x1ClockMonth-September(9),
|
|
wtWebio577xxEA1x1ClockMonth-October(10),
|
|
wtWebio577xxEA1x1ClockMonth-November(11),
|
|
wtWebio577xxEA1x1ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA1x1DeviceClock 4 }
|
|
|
|
wtWebio577xxEA1x1ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA1x1DeviceClock 5 }
|
|
|
|
-- wtWebio577xxEA1x1Network Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA1x1IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebio577xxEA1x1Network 1 }
|
|
|
|
wtWebio577xxEA1x1SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebio577xxEA1x1Network 2 }
|
|
|
|
wtWebio577xxEA1x1Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebio577xxEA1x1Network 3 }
|
|
|
|
wtWebio577xxEA1x1DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebio577xxEA1x1Network 4 }
|
|
|
|
wtWebio577xxEA1x1DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebio577xxEA1x1Network 5 }
|
|
|
|
wtWebio577xxEA1x1AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebio577xxEA1x1Network 6 }
|
|
|
|
-- wtWebio577xxEA1x1HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1Startup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebio577xxEA1x1HTTP 1 }
|
|
|
|
wtWebio577xxEA1x1GetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebio577xxEA1x1HTTP 2 }
|
|
|
|
wtWebio577xxEA1x1HttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA1x1HTTP 3 }
|
|
|
|
wtWebio577xxEA1x1HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebio577xxEA1x1HTTP 4 }
|
|
|
|
|
|
-- wtWebio577xxEA1x1Mail Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebio577xxEA1x1Mail 1 }
|
|
|
|
wtWebio577xxEA1x1MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebio577xxEA1x1Mail 2 }
|
|
|
|
wtWebio577xxEA1x1MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebio577xxEA1x1Mail 3 }
|
|
|
|
wtWebio577xxEA1x1MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebio577xxEA1x1Mail 4 }
|
|
|
|
wtWebio577xxEA1x1MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebio577xxEA1x1Mail 5 }
|
|
|
|
wtWebio577xxEA1x1MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebio577xxEA1x1Mail 6 }
|
|
|
|
wtWebio577xxEA1x1MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebio577xxEA1x1Mail 7 }
|
|
|
|
wtWebio577xxEA1x1MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebio577xxEA1x1Mail 8 }
|
|
|
|
|
|
-- wtWebio577xxEA1x1Snmp Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebio577xxEA1x1SNMP 1 }
|
|
|
|
wtWebio577xxEA1x1SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebio577xxEA1x1SNMP 2 }
|
|
|
|
wtWebio577xxEA1x1SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebio577xxEA1x1SNMP 3 }
|
|
|
|
wtWebio577xxEA1x1SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebio577xxEA1x1SNMP 4 }
|
|
|
|
wtWebio577xxEA1x1SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebio577xxEA1x1SNMP 5 }
|
|
|
|
wtWebio577xxEA1x1SnmpSystemTrapManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the system trap."
|
|
::= { wtWebio577xxEA1x1SNMP 6 }
|
|
|
|
-- wtWebio577xxEA1x1UDP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebio577xxEA1x1UDP 1 }
|
|
|
|
wtWebio577xxEA1x1UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebio577xxEA1x1UDP 2 }
|
|
|
|
wtWebio577xxEA1x1UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebio577xxEA1x1UDP 3 }
|
|
|
|
-- wtWebio577xxEA1x1Binary Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1BinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebio577xxEA1x1Binary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebio577xxEA1x1BinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebio577xxEA1x1Binary 2 }
|
|
|
|
wtWebio577xxEA1x1BinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebio577xxEA1x1BinaryModeNo }
|
|
::= { wtWebio577xxEA1x1BinaryIfTable 1 }
|
|
|
|
WtWebio577xxEA1x1BinaryIfEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1BinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA1x1BinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebio577xxEA1x1BinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1BinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebio577xxEA1x1Binary 3 }
|
|
|
|
wtWebio577xxEA1x1BinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebio577xxEA1x1BinaryModeNo }
|
|
::= { wtWebio577xxEA1x1BinaryTable 1 }
|
|
|
|
WtWebio577xxEA1x1BinaryEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1BinaryOperationMode OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryTcpServerLocalPort INTEGER,
|
|
wtWebio577xxEA1x1BinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryTcpClientLocalPort INTEGER,
|
|
wtWebio577xxEA1x1BinaryTcpClientServerPort INTEGER,
|
|
wtWebio577xxEA1x1BinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryTcpClientInactivity INTEGER,
|
|
wtWebio577xxEA1x1BinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryTcpClientInterval INTEGER,
|
|
wtWebio577xxEA1x1BinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryUdpPeerLocalPort INTEGER,
|
|
wtWebio577xxEA1x1BinaryUdpPeerRemotePort INTEGER,
|
|
wtWebio577xxEA1x1BinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryUdpPeerInterval INTEGER,
|
|
wtWebio577xxEA1x1BinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebio577xxEA1x1BinaryConnectedPort INTEGER,
|
|
wtWebio577xxEA1x1BinaryConnectedIpAddr IpAddress,
|
|
wtWebio577xxEA1x1BinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebio577xxEA1x1BinaryTcpClientServerHttpPort INTEGER,
|
|
wtWebio577xxEA1x1BinaryTcpClientServerUserName OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA1x1BinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebio577xxEA1x1BinaryEntry 1 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 2 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA1x1BinaryEntry 3 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA1x1BinaryEntry 4 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 5 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 6 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 7 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 8 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 9 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA1x1BinaryEntry 10 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 11 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA1x1BinaryEntry 12 }
|
|
|
|
wtWebio577xxEA1x1BinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 13 }
|
|
|
|
wtWebio577xxEA1x1BinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 14 }
|
|
|
|
wtWebio577xxEA1x1BinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 15 }
|
|
|
|
wtWebio577xxEA1x1BinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA1x1BinaryEntry 16 }
|
|
|
|
wtWebio577xxEA1x1BinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 17 }
|
|
|
|
wtWebio577xxEA1x1BinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA1x1BinaryEntry 18 }
|
|
|
|
wtWebio577xxEA1x1BinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 19 }
|
|
|
|
wtWebio577xxEA1x1BinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 20 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 21 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 22 }
|
|
|
|
wtWebio577xxEA1x1BinaryTcpClientServerUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Name to login at the remote server, if authentication needed."
|
|
::= { wtWebio577xxEA1x1BinaryEntry 23 }
|
|
|
|
-- wtWebio577xxEA1x1Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebio577xxEA1x1Syslog 1 }
|
|
|
|
wtWebio577xxEA1x1SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebio577xxEA1x1Syslog 2 }
|
|
|
|
wtWebio577xxEA1x1SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebio577xxEA1x1Syslog 3 }
|
|
|
|
wtWebio577xxEA1x1SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebio577xxEA1x1Syslog 4 }
|
|
|
|
-- wtWebio577xxEA1x1FTP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebio577xxEA1x1FTP 1 }
|
|
|
|
wtWebio577xxEA1x1FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebio577xxEA1x1FTP 2 }
|
|
|
|
wtWebio577xxEA1x1FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebio577xxEA1x1FTP 3 }
|
|
|
|
wtWebio577xxEA1x1FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebio577xxEA1x1FTP 4 }
|
|
|
|
wtWebio577xxEA1x1FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebio577xxEA1x1FTP 5 }
|
|
|
|
wtWebio577xxEA1x1FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebio577xxEA1x1FTP 6 }
|
|
|
|
wtWebio577xxEA1x1FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebio577xxEA1x1FTP 7 }
|
|
|
|
-- wtWebio577xxEA1x1MQTT Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1MQTTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 7 schaltet MQTT frei:
|
|
Octet 1: ungenutzt
|
|
Octet 2: ungenutzt
|
|
Octet 3: ungenutzt
|
|
Octet 4:
|
|
Bit 0-6: ungenutzt
|
|
Bit 7 : MQTT enable"
|
|
::= { wtWebio577xxEA1x1MQTT 1 }
|
|
|
|
wtWebio577xxEA1x1MQTTBrockerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP-address of the MQTT-Server."
|
|
::= { wtWebio577xxEA1x1MQTT 2 }
|
|
|
|
wtWebio577xxEA1x1MQTTUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login user name."
|
|
::= { wtWebio577xxEA1x1MQTT 3 }
|
|
|
|
wtWebio577xxEA1x1MQTTPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login password."
|
|
::= { wtWebio577xxEA1x1MQTT 4 }
|
|
|
|
wtWebio577xxEA1x1MQTTLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local port number."
|
|
::= { wtWebio577xxEA1x1MQTT 5 }
|
|
|
|
wtWebio577xxEA1x1MQTTBrokerServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Server port number."
|
|
::= { wtWebio577xxEA1x1MQTT 6 }
|
|
|
|
wtWebio577xxEA1x1MQTTInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ping intervall, if no data has to be send: time in seconds."
|
|
::= { wtWebio577xxEA1x1MQTT 7 }
|
|
|
|
wtWebio577xxEA1x1MQTTLastWillEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will enable"
|
|
::= { wtWebio577xxEA1x1MQTT 8 }
|
|
|
|
wtWebio577xxEA1x1MQTTLastWillTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Topic."
|
|
::= { wtWebio577xxEA1x1MQTT 9 }
|
|
|
|
wtWebio577xxEA1x1MQTTLastWillMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will message."
|
|
::= { wtWebio577xxEA1x1MQTT 10 }
|
|
|
|
wtWebio577xxEA1x1MQTTLastWillQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish QoS:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebio577xxEA1x1MQTT 11 }
|
|
|
|
wtWebio577xxEA1x1MQTTLastWillRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish Retain properties:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA1x1MQTT 12 }
|
|
|
|
wtWebio577xxEA1x1MQTTLastWillConnectEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill Connect message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will connect message enable"
|
|
::= { wtWebio577xxEA1x1MQTT 13 }
|
|
|
|
wtWebio577xxEA1x1MQTTLastWillConnectMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Connect message will be send with the QoS and Retain settings
|
|
of the LastWill message."
|
|
::= { wtWebio577xxEA1x1MQTT 14 }
|
|
|
|
|
|
-- wtWebio577xxEA1x1REST Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA1x1RESTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates REST:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : REST enable"
|
|
::= { wtWebio577xxEA1x1REST 1 }
|
|
|
|
wtWebio577xxEA1x1RESTDigestAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates Digest-Authentification:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Digest Auth enable"
|
|
::= { wtWebio577xxEA1x1REST 2 }
|
|
-- wtWebio577xxEA1x1OutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebio577xxEA1x1OutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebio577xxEA1x1OutputMode 1 }
|
|
|
|
wtWebio577xxEA1x1OutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebio577xxEA1x1OutputNo }
|
|
::= { wtWebio577xxEA1x1OutputModeTable 1 }
|
|
|
|
WtWebio577xxEA1x1OutputModeEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1OutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebio577xxEA1x1OutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2:
|
|
Bit 7 : unused
|
|
Bit 6 : unused
|
|
Bit 5 : unused
|
|
Bit 4 : unused
|
|
Bit 3 : unused
|
|
Bit 2 : unused
|
|
Bit 1 : REST
|
|
Bit 0 : AJAX
|
|
OCTET 3:
|
|
Bit 7 : Web Alarm
|
|
Bit 6 : ASCII Socket
|
|
Bit 5 : Time Switch
|
|
Bit 4 : Logic
|
|
Bit 3 : Binary 9
|
|
Bit 2 : Binary 8
|
|
Bit 1 : Binary 7
|
|
Bit 0 : Binary 6
|
|
OCTET 4:
|
|
Bit 7 : Binary 5
|
|
Bit 6 : Binary 4
|
|
Bit 5 : Binary 3
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebio577xxEA1x1OutputModeEntry 1 }
|
|
|
|
wtWebio577xxEA1x1SafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebio577xxEA1x1OutputMode 2 }
|
|
|
|
wtWebio577xxEA1x1LoadControlEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the function of automatic load control can be enabled. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Load Control enable"
|
|
::= { wtWebio577xxEA1x1OutputMode 3 }
|
|
|
|
|
|
-- wtWebio577xxEA1x1Alarm Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA1x1AlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebio577xxEA1x1Alarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebio577xxEA1x1AlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebio577xxEA1x1Alarm 2 }
|
|
|
|
wtWebio577xxEA1x1AlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebio577xxEA1x1AlarmNo }
|
|
::= { wtWebio577xxEA1x1AlarmIfTable 1 }
|
|
|
|
WtWebio577xxEA1x1AlarmIfEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1AlarmNo INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA1x1AlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebio577xxEA1x1AlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebio577xxEA1x1AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebio577xxEA1x1Alarm 3 }
|
|
|
|
wtWebio577xxEA1x1AlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebio577xxEA1x1AlarmNo }
|
|
::= { wtWebio577xxEA1x1AlarmTable 1 }
|
|
|
|
WtWebio577xxEA1x1AlarmEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1AlarmInputTrigger OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmOutputTrigger OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSystemTrigger OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmMaxCounterValue OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmInterval OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmEnable OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmMailAddr OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmMailSubject OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmMailText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSnmpManagerIP OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSnmpTrapText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmUdpIpAddr OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmUdpPort INTEGER,
|
|
wtWebio577xxEA1x1AlarmUdpText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmTcpIpAddr OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmTcpPort INTEGER,
|
|
wtWebio577xxEA1x1AlarmTcpText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSyslogIpAddr OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSyslogPort INTEGER,
|
|
wtWebio577xxEA1x1AlarmSyslogText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmFtpDataPort OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmFtpFileName OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmFtpText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmFtpOption OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmTimerCron OCTET STRING,
|
|
|
|
wtWebio577xxEA1x1AlarmMailReleaseSubject OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmMailReleaseText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmUdpReleaseText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmTcpReleaseText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSyslogReleaseText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmFtpReleaseText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmGlobalEnable OCTET STRING,
|
|
|
|
wtWebio577xxEA1x1AlarmCombinationLogic OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmTrgMqttTopic OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmTrgMqttTopicText OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmHttpReqAuthEnable OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmHttpReqAuthUser OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmHttpReqAuthPassword OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmHttpReqSetUrl OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmHttpReqClearUrl OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmHttpReqServerPort INTEGER,
|
|
wtWebio577xxEA1x1AlarmMqttTopicPath OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmMqttTopicSetTopic OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmMqttTopicClear OCTET STRING,
|
|
|
|
wtWebio577xxEA1x1AlarmSetOutputsOwn OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSetOutputsServerIp OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSetOutputsServerPort INTEGER,
|
|
wtWebio577xxEA1x1AlarmSetOutputsServerPassword OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSetOutputsServerOutputs OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmSetOutputsDest OCTET STRING,
|
|
|
|
wtWebio577xxEA1x1AlarmSnmpManagerPort INTEGER,
|
|
wtWebio577xxEA1x1AlarmMqttQoS OCTET STRING,
|
|
wtWebio577xxEA1x1AlarmMqttRetain OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA1x1AlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital inputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital inputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1"
|
|
|
|
::= { wtWebio577xxEA1x1AlarmEntry 1 }
|
|
|
|
wtWebio577xxEA1x1AlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1"
|
|
|
|
::= { wtWebio577xxEA1x1AlarmEntry 2 }
|
|
|
|
wtWebio577xxEA1x1AlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 3 }
|
|
|
|
wtWebio577xxEA1x1AlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebio577xxEA1x1AlarmInputTrigger are not considered."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 4 }
|
|
|
|
wtWebio577xxEA1x1AlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 5 }
|
|
|
|
wtWebio577xxEA1x1AlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Bit 0: UDP enable
|
|
Bit1-7: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: TCP Client enable
|
|
Bit 3: Syslog Messages enable
|
|
Bit 4: FTP enable
|
|
Bit 5: HTTP Request enable
|
|
Bit 6 MQTT Publish enable
|
|
Bit 7: Set Outputs"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 6 }
|
|
|
|
wtWebio577xxEA1x1AlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 7 }
|
|
|
|
wtWebio577xxEA1x1AlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 8 }
|
|
|
|
wtWebio577xxEA1x1AlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 9 }
|
|
|
|
wtWebio577xxEA1x1AlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 10 }
|
|
|
|
wtWebio577xxEA1x1AlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 11 }
|
|
|
|
wtWebio577xxEA1x1AlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 12 }
|
|
|
|
wtWebio577xxEA1x1AlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 13 }
|
|
|
|
wtWebio577xxEA1x1AlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 14 }
|
|
|
|
wtWebio577xxEA1x1AlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 15 }
|
|
|
|
wtWebio577xxEA1x1AlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 16 }
|
|
|
|
wtWebio577xxEA1x1AlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 17 }
|
|
|
|
wtWebio577xxEA1x1AlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 18 }
|
|
|
|
wtWebio577xxEA1x1AlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 19 }
|
|
|
|
wtWebio577xxEA1x1AlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 20 }
|
|
|
|
wtWebio577xxEA1x1AlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 21 }
|
|
|
|
wtWebio577xxEA1x1AlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 22 }
|
|
|
|
wtWebio577xxEA1x1AlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 23 }
|
|
|
|
wtWebio577xxEA1x1AlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 24 }
|
|
|
|
wtWebio577xxEA1x1AlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 25 }
|
|
|
|
wtWebio577xxEA1x1AlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 26 }
|
|
|
|
wtWebio577xxEA1x1AlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 27 }
|
|
|
|
wtWebio577xxEA1x1AlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 28 }
|
|
|
|
wtWebio577xxEA1x1AlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 29 }
|
|
|
|
wtWebio577xxEA1x1AlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 30 }
|
|
|
|
wtWebio577xxEA1x1AlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 31 }
|
|
|
|
wtWebio577xxEA1x1AlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 32 }
|
|
|
|
wtWebio577xxEA1x1AlarmGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Alarm enable"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 34 }
|
|
|
|
wtWebio577xxEA1x1AlarmCombinationLogic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation::
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : OR
|
|
Bit 0 : AND"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 58 }
|
|
|
|
wtWebio577xxEA1x1AlarmTrgMqttTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT subscribe topic."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 59 }
|
|
|
|
|
|
wtWebio577xxEA1x1AlarmTrgMqttTopicText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Receiving this text from the MQTT Broker, Alarm will be triggered."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 60 }
|
|
|
|
wtWebio577xxEA1x1AlarmHttpReqAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : HHTP Request Authentication enable"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 61 }
|
|
|
|
wtWebio577xxEA1x1AlarmHttpReqAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: User"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 62 }
|
|
|
|
wtWebio577xxEA1x1AlarmHttpReqAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Password"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 63 }
|
|
|
|
wtWebio577xxEA1x1AlarmHttpReqSetUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Set URL"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 64 }
|
|
|
|
wtWebio577xxEA1x1AlarmHttpReqClearUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Clear URL"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 65 }
|
|
|
|
wtWebio577xxEA1x1AlarmHttpReqServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Server Port"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 66 }
|
|
|
|
wtWebio577xxEA1x1AlarmMqttTopicPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic path"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 67 }
|
|
|
|
wtWebio577xxEA1x1AlarmMqttTopicSetTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic SET message"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 68 }
|
|
|
|
wtWebio577xxEA1x1AlarmMqttTopicClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic CLEAR message"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 69 }
|
|
|
|
wtWebio577xxEA1x1AlarmSetOutputsOwn OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0: Mask for digital outputs 0
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0: Level of digital outputs 0
|
|
|
|
OCTETS 9-12 are unused."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 70 }
|
|
|
|
wtWebio577xxEA1x1AlarmSetOutputsServerIp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server IP Address"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 71 }
|
|
|
|
wtWebio577xxEA1x1AlarmSetOutputsServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server Port"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 72 }
|
|
|
|
wtWebio577xxEA1x1AlarmSetOutputsServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server Pasword"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 73 }
|
|
|
|
wtWebio577xxEA1x1AlarmSetOutputsServerOutputs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0: Mask for digital outputs 0
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0: Level of digital outputs 0
|
|
|
|
OCTETS 9-12 are unused."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 74 }
|
|
|
|
wtWebio577xxEA1x1AlarmSetOutputsDest OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : set outputs of remote server.
|
|
Bit 0 : set outputs of this WEB-IO"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 75 }
|
|
|
|
wtWebio577xxEA1x1AlarmSnmpManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebio577xxEA1x1AlarmEntry 76 }
|
|
|
|
wtWebio577xxEA1x1AlarmMqttQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 77 }
|
|
|
|
wtWebio577xxEA1x1AlarmMqttRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA1x1AlarmEntry 78 }
|
|
|
|
-- wtWebio577xxEA1x1LoadControl
|
|
----------------------------
|
|
|
|
wtWebio577xxEA1x1LoadControlView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of automatic load control can be read. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0-1: outputs 0-1."
|
|
::= { wtWebio577xxEA1x1Alarm 4 }
|
|
|
|
wtWebio577xxEA1x1LCShutDownView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of the automatic load control shut down can be read. All outputs remain switched of,
|
|
until a zero is written into this variable. But previously all loads should be inspected.
|
|
High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason.
|
|
If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair.
|
|
All controlled output could be identified reading the variable wtWebio577xxEA1x1LoadControlEnable.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4: Bit 0-1: outputs 0-1."
|
|
::= { wtWebio577xxEA1x1Alarm 5 }
|
|
|
|
-- wtWebio577xxEA1x1Ports Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebio577xxEA1x1InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebio577xxEA1x1Ports 1 }
|
|
|
|
wtWebio577xxEA1x1InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebio577xxEA1x1InputNo }
|
|
::= { wtWebio577xxEA1x1InputPortTable 1 }
|
|
|
|
WtWebio577xxEA1x1InputPortEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1PortInputName OCTET STRING,
|
|
wtWebio577xxEA1x1PortInputText OCTET STRING,
|
|
wtWebio577xxEA1x1PortInputMode OCTET STRING,
|
|
wtWebio577xxEA1x1PortInputFilter INTEGER,
|
|
wtWebio577xxEA1x1PortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebio577xxEA1x1PortInputBicountInactivTimeout INTEGER
|
|
|
|
}
|
|
|
|
wtWebio577xxEA1x1PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebio577xxEA1x1InputPortEntry 1 }
|
|
|
|
wtWebio577xxEA1x1PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebio577xxEA1x1InputPortEntry 2 }
|
|
|
|
wtWebio577xxEA1x1PortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable"
|
|
::= { wtWebio577xxEA1x1InputPortEntry 3 }
|
|
|
|
wtWebio577xxEA1x1PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebio577xxEA1x1InputPortEntry 4 }
|
|
|
|
wtWebio577xxEA1x1PortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA1x1InputPortEntry 5 }
|
|
|
|
wtWebio577xxEA1x1PortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebio577xxEA1x1InputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebio577xxEA1x1OutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA1x1OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebio577xxEA1x1Ports 2 }
|
|
|
|
wtWebio577xxEA1x1OutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA1x1OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebio577xxEA1x1OutputNo }
|
|
::= { wtWebio577xxEA1x1OutputPortTable 1 }
|
|
|
|
WtWebio577xxEA1x1OutputPortEntry ::= SEQUENCE {
|
|
wtWebio577xxEA1x1PortOutputName OCTET STRING,
|
|
wtWebio577xxEA1x1PortOutputText OCTET STRING,
|
|
wtWebio577xxEA1x1PortOutputGroupMode OCTET STRING,
|
|
wtWebio577xxEA1x1PortOutputSafetyState OCTET STRING,
|
|
wtWebio577xxEA1x1PortLogicInputMask OCTET STRING,
|
|
wtWebio577xxEA1x1PortLogicInputInverter OCTET STRING,
|
|
wtWebio577xxEA1x1PortLogicFunction OCTET STRING,
|
|
wtWebio577xxEA1x1PortLogicOutputInverter OCTET STRING,
|
|
wtWebio577xxEA1x1PortPulseDuration INTEGER,
|
|
wtWebio577xxEA1x1PortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA1x1PortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 1 }
|
|
|
|
wtWebio577xxEA1x1PortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 2 }
|
|
|
|
wtWebio577xxEA1x1PortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one ouput bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for ouputs 0-1:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : ouputs 0,1 disconnected (default)
|
|
Bit 1 : ouputs 0+1 connected"
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 3 }
|
|
|
|
wtWebio577xxEA1x1PortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 4 }
|
|
|
|
wtWebio577xxEA1x1PortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebio577xxEA1x1PortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebio577xxEA1x1PortLogicInputInverter)
|
|
3. Logical combination (wtWebio577xxEA1x1PortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebio577xxEA1x1PortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 5 }
|
|
|
|
wtWebio577xxEA1x1PortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 6 }
|
|
|
|
wtWebio577xxEA1x1PortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 7 }
|
|
|
|
wtWebio577xxEA1x1PortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 8 }
|
|
|
|
wtWebio577xxEA1x1PortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 9 }
|
|
|
|
wtWebio577xxEA1x1PortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebio577xxEA1x1PortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA1x1OutputPortEntry 10 }
|
|
|
|
-- wtWebio577xxEA1x1Manufact Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA1x1MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebio577xxEA1x1Manufact 1 }
|
|
|
|
wtWebio577xxEA1x1MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebio577xxEA1x1Manufact 2 }
|
|
|
|
wtWebio577xxEA1x1MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebio577xxEA1x1Manufact 3 }
|
|
|
|
wtWebio577xxEA1x1MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebio577xxEA1x1Manufact 4 }
|
|
|
|
wtWebio577xxEA1x1MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebio577xxEA1x1Manufact 5 }
|
|
|
|
-- wtWebio577xxEA1x1Diag Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA1x1DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebio577xxEA1x1Diag 1 }
|
|
|
|
wtWebio577xxEA1x1DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebio577xxEA1x1Diag 2 }
|
|
|
|
wtWebio577xxEA1x1DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebio577xxEA1x1DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebio577xxEA1x1DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebio577xxEA1x1DiagErrorMessage."
|
|
::= { wtWebio577xxEA1x1Diag 3 }
|
|
|
|
wtWebio577xxEA1x1DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebio577xxEA1x1DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebio577xxEA1x1Diag 4 }
|
|
|
|
wtWebio577xxEA1x1DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebio577xxEA1x1Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebio577xxEA1x1Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebio577xxEA1x1Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebio577xxEA1x1Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebio577xxEA1x1Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebio577xxEA1x1Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebio577xxEA1x1Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebio577xxEA1x1Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebio577xxEA1x1Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebio577xxEA1x1Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebio577xxEA1x1Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebio577xxEA1x1Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebio577xxEA1x1Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebio577xxEA1x1Alert13 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebio577xxEA1x1Alert14 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebio577xxEA1x1Alert15 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebio577xxEA1x1Alert16 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebio577xxEA1x1Alert17 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebio577xxEA1x1Alert18 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebio577xxEA1x1Alert19 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebio577xxEA1x1Alert20 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebio577xxEA1x1Alert21 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebio577xxEA1x1Alert22 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebio577xxEA1x1Alert23 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebio577xxEA1x1Alert24 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES { wtWebio577xxEA1x1AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebio577xxEA1x1AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA1x1
|
|
VARIABLES {
|
|
wtWebio577xxEA1x1DiagErrorIndex,
|
|
wtWebio577xxEA1x1DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebio577xxEA2x2InOut Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA2x2Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebio577xxEA2x2InOut 1 }
|
|
|
|
wtWebio577xxEA2x2Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebio577xxEA2x2InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebio577xxEA2x2InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebio577xxEA2x2InOut 3 }
|
|
|
|
wtWebio577xxEA2x2InputEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebio577xxEA2x2InputNo }
|
|
::= { wtWebio577xxEA2x2InputTable 1 }
|
|
|
|
WtWebio577xxEA2x2InputEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2InputNo INTEGER,
|
|
wtWebio577xxEA2x2InputCounter INTEGER,
|
|
wtWebio577xxEA2x2InputCounterClear INTEGER,
|
|
wtWebio577xxEA2x2InputState INTEGER
|
|
|
|
}
|
|
|
|
wtWebio577xxEA2x2InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebio577xxEA2x2InputEntry 1 }
|
|
|
|
wtWebio577xxEA2x2InputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebio577xxEA2x2InputEntry 2 }
|
|
|
|
wtWebio577xxEA2x2InputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebio577xxEA2x2InputEntry 3 }
|
|
|
|
wtWebio577xxEA2x2InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebio577xxEA2x2InputEntry 4 }
|
|
|
|
wtWebio577xxEA2x2InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtWebio577xxEA2x2InOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebio577xxEA2x2OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebio577xxEA2x2InOut 5 }
|
|
|
|
wtWebio577xxEA2x2OutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebio577xxEA2x2OutputNo }
|
|
::= { wtWebio577xxEA2x2OutputTable 1 }
|
|
|
|
WtWebio577xxEA2x2OutputEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2OutputNo INTEGER,
|
|
wtWebio577xxEA2x2OutputState INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA2x2OutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebio577xxEA2x2OutputEntry 1 }
|
|
|
|
wtWebio577xxEA2x2OutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebio577xxEA2x2OutputEntry 2 }
|
|
|
|
|
|
wtWebio577xxEA2x2OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtWebio577xxEA2x2InOut 6 }
|
|
|
|
wtWebio577xxEA2x2SetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1"
|
|
::= { wtWebio577xxEA2x2InOut 7 }
|
|
|
|
-- wtWebio577xxEA2x2SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebio577xxEA2x2SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebio577xxEA2x2SessCntrl 1 }
|
|
|
|
wtWebio577xxEA2x2SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebio577xxEA2x2SessCntrl 2 }
|
|
|
|
wtWebio577xxEA2x2SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebio577xxEA2x2SessCntrl 3 }
|
|
|
|
wtWebio577xxEA2x2SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebio577xxEA2x2SessCntrl 4 }
|
|
|
|
wtWebio577xxEA2x2SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebio577xxEA2x2SessCntrl 5 }
|
|
|
|
-- wtWebio577xxEA2x2Text Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA2x2DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA2x2Text 1 }
|
|
|
|
wtWebio577xxEA2x2DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA2x2Text 2 }
|
|
|
|
wtWebio577xxEA2x2DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA2x2Text 3 }
|
|
|
|
wtWebio577xxEA2x2DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA2x2Text 4 }
|
|
|
|
-- wtWebio577xxEA2x2TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA2x2TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebio577xxEA2x2TimeZone 1 }
|
|
|
|
wtWebio577xxEA2x2TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebio577xxEA2x2TimeZone 2 }
|
|
|
|
wtWebio577xxEA2x2TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebio577xxEA2x2TimeZone 3 }
|
|
|
|
wtWebio577xxEA2x2StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebio577xxEA2x2TimeZone 4 }
|
|
|
|
wtWebio577xxEA2x2StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebio577xxEA2x2TimeZone 5 }
|
|
|
|
wtWebio577xxEA2x2StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebio577xxEA2x2TimeZone 6 }
|
|
|
|
wtWebio577xxEA2x2StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA2x2StartMonth-January(1),
|
|
wtWebio577xxEA2x2StartMonth-February(2),
|
|
wtWebio577xxEA2x2StartMonth-March(3),
|
|
wtWebio577xxEA2x2StartMonth-April(4),
|
|
wtWebio577xxEA2x2StartMonth-May(5),
|
|
wtWebio577xxEA2x2StartMonth-June(6),
|
|
wtWebio577xxEA2x2StartMonth-July(7),
|
|
wtWebio577xxEA2x2StartMonth-August(8),
|
|
wtWebio577xxEA2x2StartMonth-September(9),
|
|
wtWebio577xxEA2x2StartMonth-October(10),
|
|
wtWebio577xxEA2x2StartMonth-November(11),
|
|
wtWebio577xxEA2x2StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebio577xxEA2x2TimeZone 7 }
|
|
|
|
wtWebio577xxEA2x2StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA2x2StartMode-first(1),
|
|
wtWebio577xxEA2x2StartMode-second(2),
|
|
wtWebio577xxEA2x2StartMode-third(3),
|
|
wtWebio577xxEA2x2StartMode-fourth(4),
|
|
wtWebio577xxEA2x2StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebio577xxEA2x2TimeZone 8 }
|
|
|
|
wtWebio577xxEA2x2StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA2x2StartWday-Sunday(1),
|
|
wtWebio577xxEA2x2StartWday-Monday(2),
|
|
wtWebio577xxEA2x2StartWday-Tuesday(3),
|
|
wtWebio577xxEA2x2StartWday-Thursday(4),
|
|
wtWebio577xxEA2x2StartWday-Wednesday(5),
|
|
wtWebio577xxEA2x2StartWday-Friday(6),
|
|
wtWebio577xxEA2x2StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebio577xxEA2x2TimeZone 9 }
|
|
|
|
wtWebio577xxEA2x2StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA2x2TimeZone 10 }
|
|
|
|
wtWebio577xxEA2x2StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA2x2TimeZone 11 }
|
|
|
|
wtWebio577xxEA2x2StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA2x2StopMonth-January(1),
|
|
wtWebio577xxEA2x2StopMonth-February(2),
|
|
wtWebio577xxEA2x2StopMonth-March(3),
|
|
wtWebio577xxEA2x2StopMonth-April(4),
|
|
wtWebio577xxEA2x2StopMonth-May(5),
|
|
wtWebio577xxEA2x2StopMonth-June(6),
|
|
wtWebio577xxEA2x2StopMonth-July(7),
|
|
wtWebio577xxEA2x2StopMonth-August(8),
|
|
wtWebio577xxEA2x2StopMonth-September(9),
|
|
wtWebio577xxEA2x2StopMonth-October(10),
|
|
wtWebio577xxEA2x2StopMonth-November(11),
|
|
wtWebio577xxEA2x2StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA2x2TimeZone 12 }
|
|
|
|
wtWebio577xxEA2x2StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA2x2StopMode-first(1),
|
|
wtWebio577xxEA2x2StopMode-second(2),
|
|
wtWebio577xxEA2x2StopMode-third(3),
|
|
wtWebio577xxEA2x2StopMode-fourth(4),
|
|
wtWebio577xxEA2x2StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA2x2TimeZone 13 }
|
|
|
|
wtWebio577xxEA2x2StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA2x2StopWday-Sunday(1),
|
|
wtWebio577xxEA2x2StopWday-Monday(2),
|
|
wtWebio577xxEA2x2StopWday-Tuesday(3),
|
|
wtWebio577xxEA2x2StopWday-Thursday(4),
|
|
wtWebio577xxEA2x2StopWday-Wednesday(5),
|
|
wtWebio577xxEA2x2StopWday-Friday(6),
|
|
wtWebio577xxEA2x2StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA2x2TimeZone 14 }
|
|
|
|
wtWebio577xxEA2x2StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA2x2TimeZone 15 }
|
|
|
|
wtWebio577xxEA2x2StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA2x2TimeZone 16 }
|
|
|
|
-- wtWebio577xxEA2x2TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA2x2TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebio577xxEA2x2TimeServer 1 }
|
|
|
|
wtWebio577xxEA2x2TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebio577xxEA2x2TimeServer 2 }
|
|
|
|
wtWebio577xxEA2x2TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebio577xxEA2x2TimeServer 3 }
|
|
|
|
wtWebio577xxEA2x2TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebio577xxEA2x2TimeServer 4 }
|
|
|
|
|
|
-- wtWebio577xxEA2x2DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA2x2ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebio577xxEA2x2DeviceClock 1 }
|
|
|
|
wtWebio577xxEA2x2ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebio577xxEA2x2DeviceClock 2 }
|
|
|
|
wtWebio577xxEA2x2ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA2x2DeviceClock 3 }
|
|
|
|
wtWebio577xxEA2x2ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA2x2ClockMonth-January(1),
|
|
wtWebio577xxEA2x2ClockMonth-February(2),
|
|
wtWebio577xxEA2x2ClockMonth-March(3),
|
|
wtWebio577xxEA2x2ClockMonth-April(4),
|
|
wtWebio577xxEA2x2ClockMonth-May(5),
|
|
wtWebio577xxEA2x2ClockMonth-June(6),
|
|
wtWebio577xxEA2x2ClockMonth-July(7),
|
|
wtWebio577xxEA2x2ClockMonth-August(8),
|
|
wtWebio577xxEA2x2ClockMonth-September(9),
|
|
wtWebio577xxEA2x2ClockMonth-October(10),
|
|
wtWebio577xxEA2x2ClockMonth-November(11),
|
|
wtWebio577xxEA2x2ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA2x2DeviceClock 4 }
|
|
|
|
wtWebio577xxEA2x2ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA2x2DeviceClock 5 }
|
|
|
|
-- wtWebio577xxEA2x2Network Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA2x2IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebio577xxEA2x2Network 1 }
|
|
|
|
wtWebio577xxEA2x2SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebio577xxEA2x2Network 2 }
|
|
|
|
wtWebio577xxEA2x2Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebio577xxEA2x2Network 3 }
|
|
|
|
wtWebio577xxEA2x2DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebio577xxEA2x2Network 4 }
|
|
|
|
wtWebio577xxEA2x2DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebio577xxEA2x2Network 5 }
|
|
|
|
wtWebio577xxEA2x2AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebio577xxEA2x2Network 6 }
|
|
|
|
-- wtWebio577xxEA2x2HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2Startup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebio577xxEA2x2HTTP 1 }
|
|
|
|
wtWebio577xxEA2x2GetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebio577xxEA2x2HTTP 2 }
|
|
|
|
wtWebio577xxEA2x2HttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA2x2HTTP 3 }
|
|
|
|
wtWebio577xxEA2x2HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebio577xxEA2x2HTTP 4 }
|
|
|
|
|
|
-- wtWebio577xxEA2x2Mail Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebio577xxEA2x2Mail 1 }
|
|
|
|
wtWebio577xxEA2x2MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebio577xxEA2x2Mail 2 }
|
|
|
|
wtWebio577xxEA2x2MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebio577xxEA2x2Mail 3 }
|
|
|
|
wtWebio577xxEA2x2MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebio577xxEA2x2Mail 4 }
|
|
|
|
wtWebio577xxEA2x2MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebio577xxEA2x2Mail 5 }
|
|
|
|
wtWebio577xxEA2x2MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebio577xxEA2x2Mail 6 }
|
|
|
|
wtWebio577xxEA2x2MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebio577xxEA2x2Mail 7 }
|
|
|
|
wtWebio577xxEA2x2MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebio577xxEA2x2Mail 8 }
|
|
|
|
|
|
-- wtWebio577xxEA2x2Snmp Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebio577xxEA2x2SNMP 1 }
|
|
|
|
wtWebio577xxEA2x2SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebio577xxEA2x2SNMP 2 }
|
|
|
|
wtWebio577xxEA2x2SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebio577xxEA2x2SNMP 3 }
|
|
|
|
wtWebio577xxEA2x2SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebio577xxEA2x2SNMP 4 }
|
|
|
|
wtWebio577xxEA2x2SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebio577xxEA2x2SNMP 5 }
|
|
|
|
wtWebio577xxEA2x2SnmpSystemTrapManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the system trap."
|
|
::= { wtWebio577xxEA2x2SNMP 6 }
|
|
|
|
-- wtWebio577xxEA2x2UDP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebio577xxEA2x2UDP 1 }
|
|
|
|
wtWebio577xxEA2x2UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebio577xxEA2x2UDP 2 }
|
|
|
|
wtWebio577xxEA2x2UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebio577xxEA2x2UDP 3 }
|
|
|
|
-- wtWebio577xxEA2x2Binary Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2BinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebio577xxEA2x2Binary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebio577xxEA2x2BinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebio577xxEA2x2Binary 2 }
|
|
|
|
wtWebio577xxEA2x2BinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebio577xxEA2x2BinaryModeNo }
|
|
::= { wtWebio577xxEA2x2BinaryIfTable 1 }
|
|
|
|
WtWebio577xxEA2x2BinaryIfEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2BinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA2x2BinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebio577xxEA2x2BinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2BinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebio577xxEA2x2Binary 3 }
|
|
|
|
wtWebio577xxEA2x2BinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebio577xxEA2x2BinaryModeNo }
|
|
::= { wtWebio577xxEA2x2BinaryTable 1 }
|
|
|
|
WtWebio577xxEA2x2BinaryEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2BinaryOperationMode OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryTcpServerLocalPort INTEGER,
|
|
wtWebio577xxEA2x2BinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryTcpClientLocalPort INTEGER,
|
|
wtWebio577xxEA2x2BinaryTcpClientServerPort INTEGER,
|
|
wtWebio577xxEA2x2BinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryTcpClientInactivity INTEGER,
|
|
wtWebio577xxEA2x2BinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryTcpClientInterval INTEGER,
|
|
wtWebio577xxEA2x2BinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryUdpPeerLocalPort INTEGER,
|
|
wtWebio577xxEA2x2BinaryUdpPeerRemotePort INTEGER,
|
|
wtWebio577xxEA2x2BinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryUdpPeerInterval INTEGER,
|
|
wtWebio577xxEA2x2BinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebio577xxEA2x2BinaryConnectedPort INTEGER,
|
|
wtWebio577xxEA2x2BinaryConnectedIpAddr IpAddress,
|
|
wtWebio577xxEA2x2BinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebio577xxEA2x2BinaryTcpClientServerHttpPort INTEGER,
|
|
wtWebio577xxEA2x2BinaryTcpClientServerUserName OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA2x2BinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebio577xxEA2x2BinaryEntry 1 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 2 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA2x2BinaryEntry 3 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA2x2BinaryEntry 4 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 5 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 6 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 7 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 8 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 9 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA2x2BinaryEntry 10 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 11 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA2x2BinaryEntry 12 }
|
|
|
|
wtWebio577xxEA2x2BinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 13 }
|
|
|
|
wtWebio577xxEA2x2BinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 14 }
|
|
|
|
wtWebio577xxEA2x2BinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 15 }
|
|
|
|
wtWebio577xxEA2x2BinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA2x2BinaryEntry 16 }
|
|
|
|
wtWebio577xxEA2x2BinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 17 }
|
|
|
|
wtWebio577xxEA2x2BinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA2x2BinaryEntry 18 }
|
|
|
|
wtWebio577xxEA2x2BinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 19 }
|
|
|
|
wtWebio577xxEA2x2BinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 20 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 21 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 22 }
|
|
|
|
wtWebio577xxEA2x2BinaryTcpClientServerUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Name to login at the remote server, if authentication needed."
|
|
::= { wtWebio577xxEA2x2BinaryEntry 23 }
|
|
|
|
|
|
-- wtWebio577xxEA2x2Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebio577xxEA2x2Syslog 1 }
|
|
|
|
wtWebio577xxEA2x2SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebio577xxEA2x2Syslog 2 }
|
|
|
|
wtWebio577xxEA2x2SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebio577xxEA2x2Syslog 3 }
|
|
|
|
wtWebio577xxEA2x2SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebio577xxEA2x2Syslog 4 }
|
|
|
|
-- wtWebio577xxEA2x2FTP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebio577xxEA2x2FTP 1 }
|
|
|
|
wtWebio577xxEA2x2FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebio577xxEA2x2FTP 2 }
|
|
|
|
wtWebio577xxEA2x2FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebio577xxEA2x2FTP 3 }
|
|
|
|
wtWebio577xxEA2x2FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebio577xxEA2x2FTP 4 }
|
|
|
|
wtWebio577xxEA2x2FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebio577xxEA2x2FTP 5 }
|
|
|
|
wtWebio577xxEA2x2FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebio577xxEA2x2FTP 6 }
|
|
|
|
wtWebio577xxEA2x2FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebio577xxEA2x2FTP 7 }
|
|
|
|
-- wtWebio577xxEA2x2MQTT Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2MQTTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 7 schaltet MQTT frei:
|
|
Octet 1: ungenutzt
|
|
Octet 2: ungenutzt
|
|
Octet 3: ungenutzt
|
|
Octet 4:
|
|
Bit 0-6: ungenutzt
|
|
Bit 7 : MQTT enable"
|
|
::= { wtWebio577xxEA2x2MQTT 1 }
|
|
|
|
wtWebio577xxEA2x2MQTTBrockerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP-address of the MQTT-Server."
|
|
::= { wtWebio577xxEA2x2MQTT 2 }
|
|
|
|
wtWebio577xxEA2x2MQTTUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login user name."
|
|
::= { wtWebio577xxEA2x2MQTT 3 }
|
|
|
|
wtWebio577xxEA2x2MQTTPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login password."
|
|
::= { wtWebio577xxEA2x2MQTT 4 }
|
|
|
|
wtWebio577xxEA2x2MQTTLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local port number."
|
|
::= { wtWebio577xxEA2x2MQTT 5 }
|
|
|
|
wtWebio577xxEA2x2MQTTBrokerServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Server port number."
|
|
::= { wtWebio577xxEA2x2MQTT 6 }
|
|
|
|
wtWebio577xxEA2x2MQTTInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ping intervall, if no data has to be send: time in seconds."
|
|
::= { wtWebio577xxEA2x2MQTT 7 }
|
|
|
|
wtWebio577xxEA2x2MQTTLastWillEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will enable"
|
|
::= { wtWebio577xxEA2x2MQTT 8 }
|
|
|
|
wtWebio577xxEA2x2MQTTLastWillTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Topic."
|
|
::= { wtWebio577xxEA2x2MQTT 9 }
|
|
|
|
wtWebio577xxEA2x2MQTTLastWillMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will message."
|
|
::= { wtWebio577xxEA2x2MQTT 10 }
|
|
|
|
wtWebio577xxEA2x2MQTTLastWillQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish QoS:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebio577xxEA2x2MQTT 11 }
|
|
|
|
wtWebio577xxEA2x2MQTTLastWillRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish Retain properties:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA2x2MQTT 12 }
|
|
|
|
wtWebio577xxEA2x2MQTTLastWillConnectEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill Connect message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will connect message enable"
|
|
::= { wtWebio577xxEA2x2MQTT 13 }
|
|
|
|
wtWebio577xxEA2x2MQTTLastWillConnectMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Connect message will be send with the QoS and Retain settings
|
|
of the LastWill message."
|
|
::= { wtWebio577xxEA2x2MQTT 14 }
|
|
|
|
|
|
-- wtWebio577xxEA1x1REST Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA2x2RESTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates REST:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : REST enable"
|
|
::= { wtWebio577xxEA2x2REST 1 }
|
|
|
|
wtWebio577xxEA2x2RESTDigestAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates Digest-Authentification:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Digest Auth enable"
|
|
::= { wtWebio577xxEA2x2REST 2 }
|
|
|
|
-- wtWebio577xxEA2x2OutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebio577xxEA2x2OutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebio577xxEA2x2OutputMode 1 }
|
|
|
|
wtWebio577xxEA2x2OutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebio577xxEA2x2OutputNo }
|
|
::= { wtWebio577xxEA2x2OutputModeTable 1 }
|
|
|
|
WtWebio577xxEA2x2OutputModeEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2OutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebio577xxEA2x2OutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebio577xxEA2x2OutputModeEntry 1 }
|
|
|
|
wtWebio577xxEA2x2SafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebio577xxEA2x2OutputMode 2 }
|
|
|
|
wtWebio577xxEA2x2PowerSupplyEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Activate the 24V power supply..
|
|
.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Power supply enable"
|
|
::= { wtWebio577xxEA2x2OutputMode 4 }
|
|
|
|
|
|
-- wtWebio577xxEA2x2Alarm Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA2x2AlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebio577xxEA2x2Alarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebio577xxEA2x2AlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebio577xxEA2x2Alarm 2 }
|
|
|
|
wtWebio577xxEA2x2AlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebio577xxEA2x2AlarmNo }
|
|
::= { wtWebio577xxEA2x2AlarmIfTable 1 }
|
|
|
|
WtWebio577xxEA2x2AlarmIfEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2AlarmNo INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA2x2AlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebio577xxEA2x2AlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebio577xxEA2x2AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebio577xxEA2x2Alarm 3 }
|
|
|
|
wtWebio577xxEA2x2AlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebio577xxEA2x2AlarmNo }
|
|
::= { wtWebio577xxEA2x2AlarmTable 1 }
|
|
|
|
WtWebio577xxEA2x2AlarmEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2AlarmInputTrigger OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmOutputTrigger OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSystemTrigger OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmMaxCounterValue OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmInterval OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmEnable OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmMailAddr OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmMailSubject OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmMailText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSnmpManagerIP OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSnmpTrapText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmUdpIpAddr OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmUdpPort INTEGER,
|
|
wtWebio577xxEA2x2AlarmUdpText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmTcpIpAddr OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmTcpPort INTEGER,
|
|
wtWebio577xxEA2x2AlarmTcpText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSyslogIpAddr OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSyslogPort INTEGER,
|
|
wtWebio577xxEA2x2AlarmSyslogText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmFtpDataPort OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmFtpFileName OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmFtpText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmFtpOption OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmTimerCron OCTET STRING,
|
|
|
|
wtWebio577xxEA2x2AlarmMailReleaseSubject OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmMailReleaseText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmUdpReleaseText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmTcpReleaseText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSyslogReleaseText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmFtpReleaseText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmGlobalEnable OCTET STRING,
|
|
|
|
wtWebio577xxEA2x2AlarmCombinationLogic OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmTrgMqttTopic OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmTrgMqttTopicText OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmHttpReqAuthEnable OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmHttpReqAuthUser OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmHttpReqAuthPassword OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmHttpReqSetUrl OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmHttpReqClearUrl OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmHttpReqServerPort INTEGER,
|
|
wtWebio577xxEA2x2AlarmMqttTopicPath OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmMqttTopicSetTopic OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmMqttTopicClear OCTET STRING,
|
|
|
|
wtWebio577xxEA2x2AlarmSetOutputsOwn OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSetOutputsServerIp OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSetOutputsServerPort INTEGER,
|
|
wtWebio577xxEA2x2AlarmSetOutputsServerPassword OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSetOutputsServerOutputs OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmSetOutputsDest OCTET STRING,
|
|
|
|
wtWebio577xxEA2x2AlarmSnmpManagerPort INTEGER,
|
|
wtWebio577xxEA2x2AlarmMqttQoS OCTET STRING,
|
|
wtWebio577xxEA2x2AlarmMqttRetain OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA2x2AlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital inputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital inputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1"
|
|
|
|
::= { wtWebio577xxEA2x2AlarmEntry 1 }
|
|
|
|
wtWebio577xxEA2x2AlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1"
|
|
|
|
::= { wtWebio577xxEA2x2AlarmEntry 2 }
|
|
|
|
wtWebio577xxEA2x2AlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 3 }
|
|
|
|
wtWebio577xxEA2x2AlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebio577xxEA2x2AlarmInputTrigger are not considered."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 4 }
|
|
|
|
wtWebio577xxEA2x2AlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 5 }
|
|
|
|
wtWebio577xxEA2x2AlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Bit 0: UDP enable
|
|
Bit1-7: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: TCP Client enable
|
|
Bit 3: Syslog Messages enable
|
|
Bit 4: FTP enable
|
|
Bit 5: HTTP Request enable
|
|
Bit 6 MQTT Publish enable
|
|
Bit 7: Set Outputs"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 6 }
|
|
|
|
wtWebio577xxEA2x2AlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 7 }
|
|
|
|
wtWebio577xxEA2x2AlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 8 }
|
|
|
|
wtWebio577xxEA2x2AlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 9 }
|
|
|
|
wtWebio577xxEA2x2AlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 10 }
|
|
|
|
wtWebio577xxEA2x2AlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 11 }
|
|
|
|
wtWebio577xxEA2x2AlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 12 }
|
|
|
|
wtWebio577xxEA2x2AlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 13 }
|
|
|
|
wtWebio577xxEA2x2AlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 14 }
|
|
|
|
wtWebio577xxEA2x2AlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 15 }
|
|
|
|
wtWebio577xxEA2x2AlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 16 }
|
|
|
|
wtWebio577xxEA2x2AlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 17 }
|
|
|
|
wtWebio577xxEA2x2AlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 18 }
|
|
|
|
wtWebio577xxEA2x2AlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 19 }
|
|
|
|
wtWebio577xxEA2x2AlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 20 }
|
|
|
|
wtWebio577xxEA2x2AlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 21 }
|
|
|
|
wtWebio577xxEA2x2AlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 22 }
|
|
|
|
wtWebio577xxEA2x2AlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 23 }
|
|
|
|
wtWebio577xxEA2x2AlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 24 }
|
|
|
|
wtWebio577xxEA2x2AlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 25 }
|
|
|
|
wtWebio577xxEA2x2AlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 26 }
|
|
|
|
wtWebio577xxEA2x2AlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 27 }
|
|
|
|
wtWebio577xxEA2x2AlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 28 }
|
|
|
|
wtWebio577xxEA2x2AlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 29 }
|
|
|
|
wtWebio577xxEA2x2AlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 30 }
|
|
|
|
wtWebio577xxEA2x2AlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 31 }
|
|
|
|
wtWebio577xxEA2x2AlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 32 }
|
|
|
|
wtWebio577xxEA2x2AlarmGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
Bit 0 = LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Alarm enable"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 34 }
|
|
|
|
wtWebio577xxEA2x2AlarmCombinationLogic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded logic:
|
|
Bit 0 = LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : OR
|
|
Bit 0 : AND"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 58 }
|
|
|
|
wtWebio577xxEA2x2AlarmTrgMqttTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT subscribe topic."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 59 }
|
|
|
|
|
|
wtWebio577xxEA2x2AlarmTrgMqttTopicText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reveiving this message from the MQTT Broker, this alarm will be triggered."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 60 }
|
|
|
|
wtWebio577xxEA2x2AlarmHttpReqAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binnary coded value:
|
|
Bit 0 = LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : HHTP Request Authentication enable"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 61 }
|
|
|
|
wtWebio577xxEA2x2AlarmHttpReqAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: User"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 62 }
|
|
|
|
wtWebio577xxEA2x2AlarmHttpReqAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Password"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 63 }
|
|
|
|
wtWebio577xxEA2x2AlarmHttpReqSetUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Set URL"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 64 }
|
|
|
|
wtWebio577xxEA2x2AlarmHttpReqClearUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Clear URL"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 65 }
|
|
|
|
wtWebio577xxEA2x2AlarmHttpReqServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Server Port"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 66 }
|
|
|
|
wtWebio577xxEA2x2AlarmMqttTopicPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic path"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 67 }
|
|
|
|
wtWebio577xxEA2x2AlarmMqttTopicSetTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic SET message"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 68 }
|
|
|
|
wtWebio577xxEA2x2AlarmMqttTopicClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic CLEAR message"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 69 }
|
|
|
|
wtWebio577xxEA2x2AlarmSetOutputsOwn OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 are unused."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 70 }
|
|
|
|
wtWebio577xxEA2x2AlarmSetOutputsServerIp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server IP Address"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 71 }
|
|
|
|
wtWebio577xxEA2x2AlarmSetOutputsServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server Port"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 72 }
|
|
|
|
wtWebio577xxEA2x2AlarmSetOutputsServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server Pasword"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 73 }
|
|
|
|
wtWebio577xxEA2x2AlarmSetOutputsServerOutputs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 are unused."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 74 }
|
|
|
|
wtWebio577xxEA2x2AlarmSetOutputsDest OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Bit 0 = LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : set outputs of remote server.
|
|
Bit 0 : set outputs of this WEB-IO"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 75 }
|
|
|
|
wtWebio577xxEA2x2AlarmSnmpManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebio577xxEA2x2AlarmEntry 76 }
|
|
|
|
wtWebio577xxEA2x2AlarmMqttQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 77 }
|
|
|
|
wtWebio577xxEA2x2AlarmMqttRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA2x2AlarmEntry 78 }
|
|
|
|
-- wtWebio577xxEA2x2LoadControl
|
|
----------------------------
|
|
|
|
wtWebio577xxEA2x2LoadControlView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of automatic load control can be read. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0-1: outputs 0-1."
|
|
::= { wtWebio577xxEA2x2Alarm 4 }
|
|
|
|
wtWebio577xxEA2x2LCShutDownView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of the automatic load control shut down can be read. All outputs remain switched of,
|
|
until a zero is written into this variable. But previously all loads should be inspected.
|
|
High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason.
|
|
If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair.
|
|
All controlled output could be identified reading the variable wtWebio577xxEA2x2LoadControlEnable.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4: Bit 0-1: outputs 0-1."
|
|
::= { wtWebio577xxEA2x2Alarm 5 }
|
|
|
|
-- wtWebio577xxEA2x2Ports Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebio577xxEA2x2InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebio577xxEA2x2Ports 1 }
|
|
|
|
wtWebio577xxEA2x2InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebio577xxEA2x2InputNo }
|
|
::= { wtWebio577xxEA2x2InputPortTable 1 }
|
|
|
|
WtWebio577xxEA2x2InputPortEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2PortInputName OCTET STRING,
|
|
wtWebio577xxEA2x2PortInputText OCTET STRING,
|
|
wtWebio577xxEA2x2PortInputMode OCTET STRING,
|
|
wtWebio577xxEA2x2PortInputFilter INTEGER,
|
|
wtWebio577xxEA2x2PortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebio577xxEA2x2PortInputBicountInactivTimeout INTEGER
|
|
|
|
}
|
|
|
|
wtWebio577xxEA2x2PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebio577xxEA2x2InputPortEntry 1 }
|
|
|
|
wtWebio577xxEA2x2PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebio577xxEA2x2InputPortEntry 2 }
|
|
|
|
wtWebio577xxEA2x2PortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable"
|
|
::= { wtWebio577xxEA2x2InputPortEntry 3 }
|
|
|
|
wtWebio577xxEA2x2PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebio577xxEA2x2InputPortEntry 4 }
|
|
|
|
wtWebio577xxEA2x2PortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA2x2InputPortEntry 5 }
|
|
|
|
wtWebio577xxEA2x2PortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebio577xxEA2x2InputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebio577xxEA2x2OutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA2x2OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebio577xxEA2x2Ports 2 }
|
|
|
|
wtWebio577xxEA2x2OutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA2x2OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebio577xxEA2x2OutputNo }
|
|
::= { wtWebio577xxEA2x2OutputPortTable 1 }
|
|
|
|
WtWebio577xxEA2x2OutputPortEntry ::= SEQUENCE {
|
|
wtWebio577xxEA2x2PortOutputName OCTET STRING,
|
|
wtWebio577xxEA2x2PortOutputText OCTET STRING,
|
|
wtWebio577xxEA2x2PortOutputGroupMode OCTET STRING,
|
|
wtWebio577xxEA2x2PortOutputSafetyState OCTET STRING,
|
|
wtWebio577xxEA2x2PortLogicInputMask OCTET STRING,
|
|
wtWebio577xxEA2x2PortLogicInputInverter OCTET STRING,
|
|
wtWebio577xxEA2x2PortLogicFunction OCTET STRING,
|
|
wtWebio577xxEA2x2PortLogicOutputInverter OCTET STRING,
|
|
wtWebio577xxEA2x2PortPulseDuration INTEGER,
|
|
wtWebio577xxEA2x2PortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA2x2PortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 1 }
|
|
|
|
wtWebio577xxEA2x2PortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 2 }
|
|
|
|
wtWebio577xxEA2x2PortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one ouput bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for ouputs 0-1:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : ouputs 0,1 disconnected (default)
|
|
Bit 1 : ouputs 0+1 connected"
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 3 }
|
|
|
|
wtWebio577xxEA2x2PortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 4 }
|
|
|
|
wtWebio577xxEA2x2PortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebio577xxEA2x2PortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebio577xxEA2x2PortLogicInputInverter)
|
|
3. Logical combination (wtWebio577xxEA2x2PortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebio577xxEA2x2PortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 5 }
|
|
|
|
wtWebio577xxEA2x2PortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 6 }
|
|
|
|
wtWebio577xxEA2x2PortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 7 }
|
|
|
|
wtWebio577xxEA2x2PortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 8 }
|
|
|
|
wtWebio577xxEA2x2PortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 9 }
|
|
|
|
wtWebio577xxEA2x2PortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebio577xxEA2x2PortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA2x2OutputPortEntry 10 }
|
|
|
|
-- wtWebio577xxEA2x2Manufact Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA2x2MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebio577xxEA2x2Manufact 1 }
|
|
|
|
wtWebio577xxEA2x2MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebio577xxEA2x2Manufact 2 }
|
|
|
|
wtWebio577xxEA2x2MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebio577xxEA2x2Manufact 3 }
|
|
|
|
wtWebio577xxEA2x2MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebio577xxEA2x2Manufact 4 }
|
|
|
|
wtWebio577xxEA2x2MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebio577xxEA2x2Manufact 5 }
|
|
|
|
-- wtWebio577xxEA2x2Diag Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA2x2DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebio577xxEA2x2Diag 1 }
|
|
|
|
wtWebio577xxEA2x2DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebio577xxEA2x2Diag 2 }
|
|
|
|
wtWebio577xxEA2x2DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebio577xxEA2x2DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebio577xxEA2x2DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebio577xxEA2x2DiagErrorMessage."
|
|
::= { wtWebio577xxEA2x2Diag 3 }
|
|
|
|
wtWebio577xxEA2x2DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebio577xxEA2x2DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebio577xxEA2x2Diag 4 }
|
|
|
|
wtWebio577xxEA2x2DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebio577xxEA2x2Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebio577xxEA2x2Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebio577xxEA2x2Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebio577xxEA2x2Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebio577xxEA2x2Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebio577xxEA2x2Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebio577xxEA2x2Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebio577xxEA2x2Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebio577xxEA2x2Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebio577xxEA2x2Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebio577xxEA2x2Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebio577xxEA2x2Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebio577xxEA2x2Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebio577xxEA2x2Alert13 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebio577xxEA2x2Alert14 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebio577xxEA2x2Alert15 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebio577xxEA2x2Alert16 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebio577xxEA2x2Alert17 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebio577xxEA2x2Alert18 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebio577xxEA2x2Alert19 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebio577xxEA2x2Alert20 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebio577xxEA2x2Alert21 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebio577xxEA2x2Alert22 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebio577xxEA2x2Alert23 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebio577xxEA2x2Alert24 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES { wtWebio577xxEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebio577xxEA2x2AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA2x2
|
|
VARIABLES {
|
|
wtWebio577xxEA2x2DiagErrorIndex,
|
|
wtWebio577xxEA2x2DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
|
|
-- wtWebioEA2x2InOut Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebioEA2x2InOut 1 }
|
|
|
|
wtWebioEA2x2Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebioEA2x2InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA2x2InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA2x2InOut 3 }
|
|
|
|
wtWebioEA2x2InputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebioEA2x2InputNo }
|
|
::= { wtWebioEA2x2InputTable 1 }
|
|
|
|
WtWebioEA2x2InputEntry ::= SEQUENCE {
|
|
wtWebioEA2x2InputNo INTEGER,
|
|
wtWebioEA2x2InputCounter INTEGER,
|
|
wtWebioEA2x2InputCounterClear INTEGER,
|
|
wtWebioEA2x2InputState INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA2x2InputEntry 1 }
|
|
|
|
wtWebioEA2x2InputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA2x2InputEntry 2 }
|
|
|
|
wtWebioEA2x2InputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebioEA2x2InputEntry 3 }
|
|
|
|
wtWebioEA2x2InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA2x2InputEntry 4 }
|
|
|
|
wtWebioEA2x2InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtWebioEA2x2InOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA2x2OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA2x2InOut 5 }
|
|
|
|
wtWebioEA2x2OutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebioEA2x2OutputNo }
|
|
::= { wtWebioEA2x2OutputTable 1 }
|
|
|
|
WtWebioEA2x2OutputEntry ::= SEQUENCE {
|
|
wtWebioEA2x2OutputNo INTEGER,
|
|
wtWebioEA2x2OutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2OutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebioEA2x2OutputEntry 1 }
|
|
|
|
wtWebioEA2x2OutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA2x2OutputEntry 2 }
|
|
|
|
|
|
wtWebioEA2x2OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtWebioEA2x2InOut 6 }
|
|
|
|
wtWebioEA2x2SetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1"
|
|
::= { wtWebioEA2x2InOut 7 }
|
|
|
|
-- wtWebioEA2x2SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA2x2SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA2x2SessCntrl 1 }
|
|
|
|
wtWebioEA2x2SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA2x2SessCntrl 2 }
|
|
|
|
wtWebioEA2x2SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA2x2SessCntrl 3 }
|
|
|
|
wtWebioEA2x2SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA2x2SessCntrl 4 }
|
|
|
|
wtWebioEA2x2SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA2x2SessCntrl 5 }
|
|
|
|
-- wtWebioEA2x2Text Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2Text 1 }
|
|
|
|
wtWebioEA2x2DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2Text 2 }
|
|
|
|
wtWebioEA2x2DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2Text 3 }
|
|
|
|
wtWebioEA2x2DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2Text 4 }
|
|
|
|
-- wtWebioEA2x2TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA2x2TimeZone 1 }
|
|
|
|
wtWebioEA2x2TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA2x2TimeZone 2 }
|
|
|
|
wtWebioEA2x2TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA2x2TimeZone 3 }
|
|
|
|
wtWebioEA2x2StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA2x2TimeZone 4 }
|
|
|
|
wtWebioEA2x2StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA2x2TimeZone 5 }
|
|
|
|
wtWebioEA2x2StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA2x2TimeZone 6 }
|
|
|
|
wtWebioEA2x2StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2StartMonth-January(1),
|
|
wtWebioEA2x2StartMonth-February(2),
|
|
wtWebioEA2x2StartMonth-March(3),
|
|
wtWebioEA2x2StartMonth-April(4),
|
|
wtWebioEA2x2StartMonth-May(5),
|
|
wtWebioEA2x2StartMonth-June(6),
|
|
wtWebioEA2x2StartMonth-July(7),
|
|
wtWebioEA2x2StartMonth-August(8),
|
|
wtWebioEA2x2StartMonth-September(9),
|
|
wtWebioEA2x2StartMonth-October(10),
|
|
wtWebioEA2x2StartMonth-November(11),
|
|
wtWebioEA2x2StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA2x2TimeZone 7 }
|
|
|
|
wtWebioEA2x2StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2StartMode-first(1),
|
|
wtWebioEA2x2StartMode-second(2),
|
|
wtWebioEA2x2StartMode-third(3),
|
|
wtWebioEA2x2StartMode-fourth(4),
|
|
wtWebioEA2x2StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA2x2TimeZone 8 }
|
|
|
|
wtWebioEA2x2StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2StartWday-Sunday(1),
|
|
wtWebioEA2x2StartWday-Monday(2),
|
|
wtWebioEA2x2StartWday-Tuesday(3),
|
|
wtWebioEA2x2StartWday-Thursday(4),
|
|
wtWebioEA2x2StartWday-Wednesday(5),
|
|
wtWebioEA2x2StartWday-Friday(6),
|
|
wtWebioEA2x2StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA2x2TimeZone 9 }
|
|
|
|
wtWebioEA2x2StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2TimeZone 10 }
|
|
|
|
wtWebioEA2x2StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2TimeZone 11 }
|
|
|
|
wtWebioEA2x2StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2StopMonth-January(1),
|
|
wtWebioEA2x2StopMonth-February(2),
|
|
wtWebioEA2x2StopMonth-March(3),
|
|
wtWebioEA2x2StopMonth-April(4),
|
|
wtWebioEA2x2StopMonth-May(5),
|
|
wtWebioEA2x2StopMonth-June(6),
|
|
wtWebioEA2x2StopMonth-July(7),
|
|
wtWebioEA2x2StopMonth-August(8),
|
|
wtWebioEA2x2StopMonth-September(9),
|
|
wtWebioEA2x2StopMonth-October(10),
|
|
wtWebioEA2x2StopMonth-November(11),
|
|
wtWebioEA2x2StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2TimeZone 12 }
|
|
|
|
wtWebioEA2x2StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2StopMode-first(1),
|
|
wtWebioEA2x2StopMode-second(2),
|
|
wtWebioEA2x2StopMode-third(3),
|
|
wtWebioEA2x2StopMode-fourth(4),
|
|
wtWebioEA2x2StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2TimeZone 13 }
|
|
|
|
wtWebioEA2x2StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2StopWday-Sunday(1),
|
|
wtWebioEA2x2StopWday-Monday(2),
|
|
wtWebioEA2x2StopWday-Tuesday(3),
|
|
wtWebioEA2x2StopWday-Thursday(4),
|
|
wtWebioEA2x2StopWday-Wednesday(5),
|
|
wtWebioEA2x2StopWday-Friday(6),
|
|
wtWebioEA2x2StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2TimeZone 14 }
|
|
|
|
wtWebioEA2x2StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2TimeZone 15 }
|
|
|
|
wtWebioEA2x2StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2TimeZone 16 }
|
|
|
|
-- wtWebioEA2x2TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA2x2TimeServer 1 }
|
|
|
|
wtWebioEA2x2TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA2x2TimeServer 2 }
|
|
|
|
wtWebioEA2x2TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA2x2TimeServer 3 }
|
|
|
|
wtWebioEA2x2TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA2x2TimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA2x2DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA2x2DeviceClock 1 }
|
|
|
|
wtWebioEA2x2ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA2x2DeviceClock 2 }
|
|
|
|
wtWebioEA2x2ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2DeviceClock 3 }
|
|
|
|
wtWebioEA2x2ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ClockMonth-January(1),
|
|
wtWebioEA2x2ClockMonth-February(2),
|
|
wtWebioEA2x2ClockMonth-March(3),
|
|
wtWebioEA2x2ClockMonth-April(4),
|
|
wtWebioEA2x2ClockMonth-May(5),
|
|
wtWebioEA2x2ClockMonth-June(6),
|
|
wtWebioEA2x2ClockMonth-July(7),
|
|
wtWebioEA2x2ClockMonth-August(8),
|
|
wtWebioEA2x2ClockMonth-September(9),
|
|
wtWebioEA2x2ClockMonth-October(10),
|
|
wtWebioEA2x2ClockMonth-November(11),
|
|
wtWebioEA2x2ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2DeviceClock 4 }
|
|
|
|
wtWebioEA2x2ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2DeviceClock 5 }
|
|
|
|
-- wtWebioEA2x2Network Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA2x2Network 1 }
|
|
|
|
wtWebioEA2x2SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA2x2Network 2 }
|
|
|
|
wtWebioEA2x2Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA2x2Network 3 }
|
|
|
|
wtWebioEA2x2DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA2x2Network 4 }
|
|
|
|
wtWebioEA2x2DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA2x2Network 5 }
|
|
|
|
wtWebioEA2x2AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA2x2Network 6 }
|
|
|
|
-- wtWebioEA2x2HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2Startup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA2x2HTTP 1 }
|
|
|
|
wtWebioEA2x2GetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA2x2HTTP 2 }
|
|
|
|
wtWebioEA2x2HttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2HTTP 3 }
|
|
|
|
wtWebioEA2x2HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA2x2HTTP 4 }
|
|
|
|
|
|
-- wtWebioEA2x2Mail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA2x2Mail 1 }
|
|
|
|
wtWebioEA2x2MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA2x2Mail 2 }
|
|
|
|
wtWebioEA2x2MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA2x2Mail 3 }
|
|
|
|
wtWebioEA2x2MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA2x2Mail 4 }
|
|
|
|
wtWebioEA2x2MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA2x2Mail 5 }
|
|
|
|
wtWebioEA2x2MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA2x2Mail 6 }
|
|
|
|
wtWebioEA2x2MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA2x2Mail 7 }
|
|
|
|
wtWebioEA2x2MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA2x2Mail 8 }
|
|
|
|
|
|
-- wtWebioEA2x2Snmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA2x2SNMP 1 }
|
|
|
|
wtWebioEA2x2SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA2x2SNMP 2 }
|
|
|
|
wtWebioEA2x2SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA2x2SNMP 3 }
|
|
|
|
wtWebioEA2x2SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA2x2SNMP 4 }
|
|
|
|
wtWebioEA2x2SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA2x2SNMP 5 }
|
|
|
|
-- wtWebioEA2x2UDP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA2x2UDP 1 }
|
|
|
|
wtWebioEA2x2UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA2x2UDP 2 }
|
|
|
|
wtWebioEA2x2UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA2x2UDP 3 }
|
|
|
|
-- wtWebioEA2x2Binary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2BinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA2x2Binary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA2x2BinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA2x2Binary 2 }
|
|
|
|
wtWebioEA2x2BinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA2x2BinaryModeNo }
|
|
::= { wtWebioEA2x2BinaryIfTable 1 }
|
|
|
|
WtWebioEA2x2BinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA2x2BinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2BinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA2x2BinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2BinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA2x2Binary 3 }
|
|
|
|
wtWebioEA2x2BinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA2x2BinaryModeNo }
|
|
::= { wtWebioEA2x2BinaryTable 1 }
|
|
|
|
WtWebioEA2x2BinaryEntry ::= SEQUENCE {
|
|
wtWebioEA2x2BinaryOperationMode OCTET STRING,
|
|
wtWebioEA2x2BinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA2x2BinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA2x2BinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA2x2BinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA2x2BinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA2x2BinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA2x2BinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA2x2BinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA2x2BinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA2x2BinaryTcpClientInterval INTEGER,
|
|
wtWebioEA2x2BinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA2x2BinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA2x2BinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA2x2BinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA2x2BinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA2x2BinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA2x2BinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA2x2BinaryConnectedPort INTEGER,
|
|
wtWebioEA2x2BinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA2x2BinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA2x2BinaryTcpClientServerHttpPort INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2BinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA2x2BinaryEntry 1 }
|
|
|
|
wtWebioEA2x2BinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2BinaryEntry 2 }
|
|
|
|
wtWebioEA2x2BinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2BinaryEntry 3 }
|
|
|
|
wtWebioEA2x2BinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2BinaryEntry 4 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2BinaryEntry 5 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA2x2BinaryEntry 6 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA2x2BinaryEntry 7 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA2x2BinaryEntry 8 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA2x2BinaryEntry 9 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2BinaryEntry 10 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA2x2BinaryEntry 11 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2BinaryEntry 12 }
|
|
|
|
wtWebioEA2x2BinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2BinaryEntry 13 }
|
|
|
|
wtWebioEA2x2BinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA2x2BinaryEntry 14 }
|
|
|
|
wtWebioEA2x2BinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA2x2BinaryEntry 15 }
|
|
|
|
wtWebioEA2x2BinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2BinaryEntry 16 }
|
|
|
|
wtWebioEA2x2BinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA2x2BinaryEntry 17 }
|
|
|
|
wtWebioEA2x2BinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2BinaryEntry 18 }
|
|
|
|
wtWebioEA2x2BinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA2x2BinaryEntry 19 }
|
|
|
|
wtWebioEA2x2BinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA2x2BinaryEntry 20 }
|
|
|
|
wtWebioEA2x2BinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA2x2BinaryEntry 21 }
|
|
|
|
wtWebioEA2x2BinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA2x2BinaryEntry 22 }
|
|
|
|
-- wtWebioEA2x2Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA2x2Syslog 1 }
|
|
|
|
wtWebioEA2x2SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA2x2Syslog 2 }
|
|
|
|
wtWebioEA2x2SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA2x2Syslog 3 }
|
|
|
|
wtWebioEA2x2SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA2x2Syslog 4 }
|
|
|
|
-- wtWebioEA2x2FTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA2x2FTP 1 }
|
|
|
|
wtWebioEA2x2FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA2x2FTP 2 }
|
|
|
|
wtWebioEA2x2FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA2x2FTP 3 }
|
|
|
|
wtWebioEA2x2FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA2x2FTP 4 }
|
|
|
|
wtWebioEA2x2FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA2x2FTP 5 }
|
|
|
|
wtWebioEA2x2FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA2x2FTP 6 }
|
|
|
|
wtWebioEA2x2FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA2x2FTP 7 }
|
|
|
|
-- wtWebioEA2x2OutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA2x2OutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA2x2OutputMode 1 }
|
|
|
|
wtWebioEA2x2OutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA2x2OutputNo }
|
|
::= { wtWebioEA2x2OutputModeTable 1 }
|
|
|
|
WtWebioEA2x2OutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA2x2OutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA2x2OutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA2x2OutputModeEntry 1 }
|
|
|
|
wtWebioEA2x2SafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA2x2OutputMode 2 }
|
|
|
|
wtWebioEA2x2LoadControlEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the function of automatic load control can be enabled. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Load Control enable"
|
|
::= { wtWebioEA2x2OutputMode 3 }
|
|
|
|
|
|
-- wtWebioEA2x2Alarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2AlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA2x2Alarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA2x2AlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA2x2Alarm 2 }
|
|
|
|
wtWebioEA2x2AlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA2x2AlarmNo }
|
|
::= { wtWebioEA2x2AlarmIfTable 1 }
|
|
|
|
WtWebioEA2x2AlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA2x2AlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2AlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA2x2AlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA2x2AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA2x2Alarm 3 }
|
|
|
|
wtWebioEA2x2AlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA2x2AlarmNo }
|
|
::= { wtWebioEA2x2AlarmTable 1 }
|
|
|
|
WtWebioEA2x2AlarmEntry ::= SEQUENCE {
|
|
wtWebioEA2x2AlarmInputTrigger OCTET STRING,
|
|
wtWebioEA2x2AlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA2x2AlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA2x2AlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA2x2AlarmInterval OCTET STRING,
|
|
wtWebioEA2x2AlarmEnable OCTET STRING,
|
|
wtWebioEA2x2AlarmMailAddr OCTET STRING,
|
|
wtWebioEA2x2AlarmMailSubject OCTET STRING,
|
|
wtWebioEA2x2AlarmMailText OCTET STRING,
|
|
wtWebioEA2x2AlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA2x2AlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA2x2AlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA2x2AlarmUdpPort INTEGER,
|
|
wtWebioEA2x2AlarmUdpText OCTET STRING,
|
|
wtWebioEA2x2AlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA2x2AlarmTcpPort INTEGER,
|
|
wtWebioEA2x2AlarmTcpText OCTET STRING,
|
|
wtWebioEA2x2AlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA2x2AlarmSyslogPort INTEGER,
|
|
wtWebioEA2x2AlarmSyslogText OCTET STRING,
|
|
wtWebioEA2x2AlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA2x2AlarmFtpFileName OCTET STRING,
|
|
wtWebioEA2x2AlarmFtpText OCTET STRING,
|
|
wtWebioEA2x2AlarmFtpOption OCTET STRING,
|
|
wtWebioEA2x2AlarmTimerCron OCTET STRING,
|
|
|
|
wtWebioEA2x2AlarmMailReleaseSubject OCTET STRING,
|
|
wtWebioEA2x2AlarmMailReleaseText OCTET STRING,
|
|
wtWebioEA2x2AlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebioEA2x2AlarmUdpReleaseText OCTET STRING,
|
|
wtWebioEA2x2AlarmTcpReleaseText OCTET STRING,
|
|
wtWebioEA2x2AlarmSyslogReleaseText OCTET STRING,
|
|
wtWebioEA2x2AlarmFtpReleaseText OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA2x2AlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital inputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital inputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1"
|
|
|
|
::= { wtWebioEA2x2AlarmEntry 1 }
|
|
|
|
wtWebioEA2x2AlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1"
|
|
|
|
::= { wtWebioEA2x2AlarmEntry 2 }
|
|
|
|
wtWebioEA2x2AlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebioEA2x2AlarmEntry 3 }
|
|
|
|
wtWebioEA2x2AlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA2x2AlarmInputTrigger are not considered."
|
|
::= { wtWebioEA2x2AlarmEntry 4 }
|
|
|
|
wtWebioEA2x2AlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA2x2AlarmEntry 5 }
|
|
|
|
wtWebioEA2x2AlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA2x2AlarmEntry 6 }
|
|
|
|
wtWebioEA2x2AlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA2x2AlarmEntry 7 }
|
|
|
|
wtWebioEA2x2AlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA2x2AlarmEntry 8 }
|
|
|
|
wtWebioEA2x2AlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA2x2AlarmEntry 9 }
|
|
|
|
wtWebioEA2x2AlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA2x2AlarmEntry 10 }
|
|
|
|
wtWebioEA2x2AlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA2x2AlarmEntry 11 }
|
|
|
|
wtWebioEA2x2AlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA2x2AlarmEntry 12 }
|
|
|
|
wtWebioEA2x2AlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA2x2AlarmEntry 13 }
|
|
|
|
wtWebioEA2x2AlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA2x2AlarmEntry 14 }
|
|
|
|
wtWebioEA2x2AlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA2x2AlarmEntry 15 }
|
|
|
|
wtWebioEA2x2AlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA2x2AlarmEntry 16 }
|
|
|
|
wtWebioEA2x2AlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA2x2AlarmEntry 17 }
|
|
|
|
wtWebioEA2x2AlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA2x2AlarmEntry 18 }
|
|
|
|
wtWebioEA2x2AlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA2x2AlarmEntry 19 }
|
|
|
|
wtWebioEA2x2AlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA2x2AlarmEntry 20 }
|
|
|
|
wtWebioEA2x2AlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA2x2AlarmEntry 21 }
|
|
|
|
wtWebioEA2x2AlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA2x2AlarmEntry 22 }
|
|
|
|
wtWebioEA2x2AlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA2x2AlarmEntry 23 }
|
|
|
|
wtWebioEA2x2AlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA2x2AlarmEntry 24 }
|
|
|
|
wtWebioEA2x2AlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA2x2AlarmEntry 25 }
|
|
|
|
wtWebioEA2x2AlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA2x2AlarmEntry 26 }
|
|
|
|
wtWebioEA2x2AlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA2x2AlarmEntry 27 }
|
|
|
|
wtWebioEA2x2AlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA2x2AlarmEntry 28 }
|
|
|
|
wtWebioEA2x2AlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA2x2AlarmEntry 29 }
|
|
|
|
wtWebioEA2x2AlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA2x2AlarmEntry 30 }
|
|
|
|
wtWebioEA2x2AlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA2x2AlarmEntry 31 }
|
|
|
|
wtWebioEA2x2AlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA2x2AlarmEntry 32 }
|
|
|
|
-- wtWebioEA2x2LoadControl
|
|
----------------------------
|
|
|
|
wtWebioEA2x2LoadControlView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of automatic load control can be read. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0-1: outputs 0-1."
|
|
::= { wtWebioEA2x2Alarm 4 }
|
|
|
|
wtWebioEA2x2LCShutDownView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of the automatic load control shut down can be read. All outputs remain switched of,
|
|
until a zero is written into this variable. But previously all loads should be inspected.
|
|
High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason.
|
|
If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair.
|
|
All controlled output could be identified reading the variable wtWebioEA2x2LoadControlEnable.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4: Bit 0-1: outputs 0-1."
|
|
::= { wtWebioEA2x2Alarm 5 }
|
|
|
|
-- wtWebioEA2x2Ports Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA2x2InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA2x2Ports 1 }
|
|
|
|
wtWebioEA2x2InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA2x2InputNo }
|
|
::= { wtWebioEA2x2InputPortTable 1 }
|
|
|
|
WtWebioEA2x2InputPortEntry ::= SEQUENCE {
|
|
wtWebioEA2x2PortInputName OCTET STRING,
|
|
wtWebioEA2x2PortInputText OCTET STRING,
|
|
wtWebioEA2x2PortInputMode OCTET STRING,
|
|
wtWebioEA2x2PortInputFilter INTEGER,
|
|
wtWebioEA2x2PortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebioEA2x2PortInputBicountInactivTimeout INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA2x2InputPortEntry 1 }
|
|
|
|
wtWebioEA2x2PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA2x2InputPortEntry 2 }
|
|
|
|
wtWebioEA2x2PortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable"
|
|
::= { wtWebioEA2x2InputPortEntry 3 }
|
|
|
|
wtWebioEA2x2PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA2x2InputPortEntry 4 }
|
|
|
|
wtWebioEA2x2PortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2InputPortEntry 5 }
|
|
|
|
wtWebioEA2x2PortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebioEA2x2InputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA2x2OutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA2x2Ports 2 }
|
|
|
|
wtWebioEA2x2OutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA2x2OutputNo }
|
|
::= { wtWebioEA2x2OutputPortTable 1 }
|
|
|
|
WtWebioEA2x2OutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA2x2PortOutputName OCTET STRING,
|
|
wtWebioEA2x2PortOutputText OCTET STRING,
|
|
wtWebioEA2x2PortOutputGroupMode OCTET STRING,
|
|
wtWebioEA2x2PortOutputSafetyState OCTET STRING,
|
|
wtWebioEA2x2PortLogicInputMask OCTET STRING,
|
|
wtWebioEA2x2PortLogicInputInverter OCTET STRING,
|
|
wtWebioEA2x2PortLogicFunction OCTET STRING,
|
|
wtWebioEA2x2PortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA2x2PortPulseDuration INTEGER,
|
|
wtWebioEA2x2PortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA2x2PortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA2x2OutputPortEntry 1 }
|
|
|
|
wtWebioEA2x2PortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA2x2OutputPortEntry 2 }
|
|
|
|
wtWebioEA2x2PortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one ouput bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for ouputs 0-1:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : ouputs 0,1 disconnected (default)
|
|
Bit 1 : ouputs 0+1 connected"
|
|
::= { wtWebioEA2x2OutputPortEntry 3 }
|
|
|
|
wtWebioEA2x2PortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebioEA2x2OutputPortEntry 4 }
|
|
|
|
wtWebioEA2x2PortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA2x2PortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA2x2PortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA2x2PortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA2x2PortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebioEA2x2OutputPortEntry 5 }
|
|
|
|
wtWebioEA2x2PortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebioEA2x2OutputPortEntry 6 }
|
|
|
|
wtWebioEA2x2PortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2OutputPortEntry 7 }
|
|
|
|
wtWebioEA2x2PortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA2x2OutputPortEntry 8 }
|
|
|
|
wtWebioEA2x2PortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA2x2OutputPortEntry 9 }
|
|
|
|
wtWebioEA2x2PortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA2x2PortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2OutputPortEntry 10 }
|
|
|
|
-- wtWebioEA2x2Manufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA2x2Manufact 1 }
|
|
|
|
wtWebioEA2x2MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA2x2Manufact 2 }
|
|
|
|
wtWebioEA2x2MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA2x2Manufact 3 }
|
|
|
|
wtWebioEA2x2MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA2x2Manufact 4 }
|
|
|
|
wtWebioEA2x2MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA2x2Manufact 5 }
|
|
|
|
-- wtWebioEA2x2Diag Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA2x2Diag 1 }
|
|
|
|
wtWebioEA2x2DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA2x2Diag 2 }
|
|
|
|
wtWebioEA2x2DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA2x2DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA2x2DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA2x2DiagErrorMessage."
|
|
::= { wtWebioEA2x2Diag 3 }
|
|
|
|
wtWebioEA2x2DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA2x2DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA2x2Diag 4 }
|
|
|
|
wtWebioEA2x2DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA2x2Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA2x2Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebioEA2x2Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebioEA2x2Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebioEA2x2Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebioEA2x2Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebioEA2x2Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebioEA2x2Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebioEA2x2Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebioEA2x2Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebioEA2x2Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebioEA2x2Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebioEA2x2Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebioEA2x2Alert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA2x2Alert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA2x2Alert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA2x2Alert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA2x2Alert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA2x2Alert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA2x2Alert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA2x2Alert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA2x2Alert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA2x2Alert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA2x2Alert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA2x2Alert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES { wtWebioEA2x2AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA2x2AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2
|
|
VARIABLES {
|
|
wtWebioEA2x2DiagErrorIndex,
|
|
wtWebioEA2x2DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebio577xxEA12x12InOut Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA12x12Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebio577xxEA12x12InOut 1 }
|
|
|
|
wtWebio577xxEA12x12Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebio577xxEA12x12InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebio577xxEA12x12InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebio577xxEA12x12InOut 3 }
|
|
|
|
wtWebio577xxEA12x12InputEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebio577xxEA12x12InputNo }
|
|
::= { wtWebio577xxEA12x12InputTable 1 }
|
|
|
|
WtWebio577xxEA12x12InputEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12InputNo INTEGER,
|
|
wtWebio577xxEA12x12InputCounter INTEGER,
|
|
wtWebio577xxEA12x12InputCounterClear INTEGER,
|
|
wtWebio577xxEA12x12InputState INTEGER
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x12InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebio577xxEA12x12InputEntry 1 }
|
|
|
|
wtWebio577xxEA12x12InputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebio577xxEA12x12InputEntry 2 }
|
|
|
|
wtWebio577xxEA12x12InputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebio577xxEA12x12InputEntry 3 }
|
|
|
|
wtWebio577xxEA12x12InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebio577xxEA12x12InputEntry 4 }
|
|
|
|
wtWebio577xxEA12x12InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3: Digital outputs 8-11
|
|
OCTET 4, Bit 0-7: Digital outputs 0-7"
|
|
::= { wtWebio577xxEA12x12InOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebio577xxEA12x12OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebio577xxEA12x12InOut 5 }
|
|
|
|
wtWebio577xxEA12x12OutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebio577xxEA12x12OutputNo }
|
|
::= { wtWebio577xxEA12x12OutputTable 1 }
|
|
|
|
WtWebio577xxEA12x12OutputEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12OutputNo INTEGER,
|
|
wtWebio577xxEA12x12OutputState INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA12x12OutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebio577xxEA12x12OutputEntry 1 }
|
|
|
|
wtWebio577xxEA12x12OutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebio577xxEA12x12OutputEntry 2 }
|
|
|
|
|
|
wtWebio577xxEA12x12OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3: Digital outputs 8-11
|
|
OCTET 4, Bit 0-7: Digital outputs 0-7"
|
|
|
|
::= { wtWebio577xxEA12x12InOut 6 }
|
|
|
|
wtWebio577xxEA12x12SetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : Bit 0-3: Mask for digital outputs 8-11
|
|
OCTET 4 : Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : Bit 0-3: Mask for digital outputs 8-11
|
|
OCTET 8 : Bit 0-7: Mask for digital outputs 0-7"
|
|
::= { wtWebio577xxEA12x12InOut 7 }
|
|
|
|
-- wtWebio577xxEA12x12SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebio577xxEA12x12SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebio577xxEA12x12SessCntrl 1 }
|
|
|
|
wtWebio577xxEA12x12SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebio577xxEA12x12SessCntrl 2 }
|
|
|
|
wtWebio577xxEA12x12SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebio577xxEA12x12SessCntrl 3 }
|
|
|
|
wtWebio577xxEA12x12SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebio577xxEA12x12SessCntrl 4 }
|
|
|
|
wtWebio577xxEA12x12SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebio577xxEA12x12SessCntrl 5 }
|
|
|
|
-- wtWebio577xxEA12x12Text Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA12x12DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA12x12Text 1 }
|
|
|
|
wtWebio577xxEA12x12DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA12x12Text 2 }
|
|
|
|
wtWebio577xxEA12x12DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA12x12Text 3 }
|
|
|
|
wtWebio577xxEA12x12DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA12x12Text 4 }
|
|
|
|
-- wtWebio577xxEA12x12TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x12TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebio577xxEA12x12TimeZone 1 }
|
|
|
|
wtWebio577xxEA12x12TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebio577xxEA12x12TimeZone 2 }
|
|
|
|
wtWebio577xxEA12x12TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebio577xxEA12x12TimeZone 3 }
|
|
|
|
wtWebio577xxEA12x12StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebio577xxEA12x12TimeZone 4 }
|
|
|
|
wtWebio577xxEA12x12StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebio577xxEA12x12TimeZone 5 }
|
|
|
|
wtWebio577xxEA12x12StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebio577xxEA12x12TimeZone 6 }
|
|
|
|
wtWebio577xxEA12x12StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x12StartMonth-January(1),
|
|
wtWebio577xxEA12x12StartMonth-February(2),
|
|
wtWebio577xxEA12x12StartMonth-March(3),
|
|
wtWebio577xxEA12x12StartMonth-April(4),
|
|
wtWebio577xxEA12x12StartMonth-May(5),
|
|
wtWebio577xxEA12x12StartMonth-June(6),
|
|
wtWebio577xxEA12x12StartMonth-July(7),
|
|
wtWebio577xxEA12x12StartMonth-August(8),
|
|
wtWebio577xxEA12x12StartMonth-September(9),
|
|
wtWebio577xxEA12x12StartMonth-October(10),
|
|
wtWebio577xxEA12x12StartMonth-November(11),
|
|
wtWebio577xxEA12x12StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebio577xxEA12x12TimeZone 7 }
|
|
|
|
wtWebio577xxEA12x12StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x12StartMode-first(1),
|
|
wtWebio577xxEA12x12StartMode-second(2),
|
|
wtWebio577xxEA12x12StartMode-third(3),
|
|
wtWebio577xxEA12x12StartMode-fourth(4),
|
|
wtWebio577xxEA12x12StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebio577xxEA12x12TimeZone 8 }
|
|
|
|
wtWebio577xxEA12x12StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x12StartWday-Sunday(1),
|
|
wtWebio577xxEA12x12StartWday-Monday(2),
|
|
wtWebio577xxEA12x12StartWday-Tuesday(3),
|
|
wtWebio577xxEA12x12StartWday-Thursday(4),
|
|
wtWebio577xxEA12x12StartWday-Wednesday(5),
|
|
wtWebio577xxEA12x12StartWday-Friday(6),
|
|
wtWebio577xxEA12x12StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebio577xxEA12x12TimeZone 9 }
|
|
|
|
wtWebio577xxEA12x12StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA12x12TimeZone 10 }
|
|
|
|
wtWebio577xxEA12x12StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA12x12TimeZone 11 }
|
|
|
|
wtWebio577xxEA12x12StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x12StopMonth-January(1),
|
|
wtWebio577xxEA12x12StopMonth-February(2),
|
|
wtWebio577xxEA12x12StopMonth-March(3),
|
|
wtWebio577xxEA12x12StopMonth-April(4),
|
|
wtWebio577xxEA12x12StopMonth-May(5),
|
|
wtWebio577xxEA12x12StopMonth-June(6),
|
|
wtWebio577xxEA12x12StopMonth-July(7),
|
|
wtWebio577xxEA12x12StopMonth-August(8),
|
|
wtWebio577xxEA12x12StopMonth-September(9),
|
|
wtWebio577xxEA12x12StopMonth-October(10),
|
|
wtWebio577xxEA12x12StopMonth-November(11),
|
|
wtWebio577xxEA12x12StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA12x12TimeZone 12 }
|
|
|
|
wtWebio577xxEA12x12StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x12StopMode-first(1),
|
|
wtWebio577xxEA12x12StopMode-second(2),
|
|
wtWebio577xxEA12x12StopMode-third(3),
|
|
wtWebio577xxEA12x12StopMode-fourth(4),
|
|
wtWebio577xxEA12x12StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA12x12TimeZone 13 }
|
|
|
|
wtWebio577xxEA12x12StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x12StopWday-Sunday(1),
|
|
wtWebio577xxEA12x12StopWday-Monday(2),
|
|
wtWebio577xxEA12x12StopWday-Tuesday(3),
|
|
wtWebio577xxEA12x12StopWday-Thursday(4),
|
|
wtWebio577xxEA12x12StopWday-Wednesday(5),
|
|
wtWebio577xxEA12x12StopWday-Friday(6),
|
|
wtWebio577xxEA12x12StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA12x12TimeZone 14 }
|
|
|
|
wtWebio577xxEA12x12StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA12x12TimeZone 15 }
|
|
|
|
wtWebio577xxEA12x12StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA12x12TimeZone 16 }
|
|
|
|
-- wtWebio577xxEA12x12TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x12TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebio577xxEA12x12TimeServer 1 }
|
|
|
|
wtWebio577xxEA12x12TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebio577xxEA12x12TimeServer 2 }
|
|
|
|
wtWebio577xxEA12x12TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebio577xxEA12x12TimeServer 3 }
|
|
|
|
wtWebio577xxEA12x12TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebio577xxEA12x12TimeServer 4 }
|
|
|
|
|
|
-- wtWebio577xxEA12x12DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x12ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x12DeviceClock 1 }
|
|
|
|
wtWebio577xxEA12x12ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x12DeviceClock 2 }
|
|
|
|
wtWebio577xxEA12x12ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x12DeviceClock 3 }
|
|
|
|
wtWebio577xxEA12x12ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x12ClockMonth-January(1),
|
|
wtWebio577xxEA12x12ClockMonth-February(2),
|
|
wtWebio577xxEA12x12ClockMonth-March(3),
|
|
wtWebio577xxEA12x12ClockMonth-April(4),
|
|
wtWebio577xxEA12x12ClockMonth-May(5),
|
|
wtWebio577xxEA12x12ClockMonth-June(6),
|
|
wtWebio577xxEA12x12ClockMonth-July(7),
|
|
wtWebio577xxEA12x12ClockMonth-August(8),
|
|
wtWebio577xxEA12x12ClockMonth-September(9),
|
|
wtWebio577xxEA12x12ClockMonth-October(10),
|
|
wtWebio577xxEA12x12ClockMonth-November(11),
|
|
wtWebio577xxEA12x12ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x12DeviceClock 4 }
|
|
|
|
wtWebio577xxEA12x12ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x12DeviceClock 5 }
|
|
|
|
-- wtWebio577xxEA12x12Network Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA12x12IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebio577xxEA12x12Network 1 }
|
|
|
|
wtWebio577xxEA12x12SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebio577xxEA12x12Network 2 }
|
|
|
|
wtWebio577xxEA12x12Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebio577xxEA12x12Network 3 }
|
|
|
|
wtWebio577xxEA12x12DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebio577xxEA12x12Network 4 }
|
|
|
|
wtWebio577xxEA12x12DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebio577xxEA12x12Network 5 }
|
|
|
|
wtWebio577xxEA12x12AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebio577xxEA12x12Network 6 }
|
|
|
|
-- wtWebio577xxEA12x12HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12Startup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebio577xxEA12x12HTTP 1 }
|
|
|
|
wtWebio577xxEA12x12GetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebio577xxEA12x12HTTP 2 }
|
|
|
|
wtWebio577xxEA12x12HttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA12x12HTTP 3 }
|
|
|
|
wtWebio577xxEA12x12HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebio577xxEA12x12HTTP 4 }
|
|
|
|
|
|
-- wtWebio577xxEA12x12Mail Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebio577xxEA12x12Mail 1 }
|
|
|
|
wtWebio577xxEA12x12MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebio577xxEA12x12Mail 2 }
|
|
|
|
wtWebio577xxEA12x12MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebio577xxEA12x12Mail 3 }
|
|
|
|
wtWebio577xxEA12x12MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebio577xxEA12x12Mail 4 }
|
|
|
|
wtWebio577xxEA12x12MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebio577xxEA12x12Mail 5 }
|
|
|
|
wtWebio577xxEA12x12MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebio577xxEA12x12Mail 6 }
|
|
|
|
wtWebio577xxEA12x12MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebio577xxEA12x12Mail 7 }
|
|
|
|
wtWebio577xxEA12x12MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebio577xxEA12x12Mail 8 }
|
|
|
|
|
|
-- wtWebio577xxEA12x12Snmp Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebio577xxEA12x12SNMP 1 }
|
|
|
|
wtWebio577xxEA12x12SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebio577xxEA12x12SNMP 2 }
|
|
|
|
wtWebio577xxEA12x12SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebio577xxEA12x12SNMP 3 }
|
|
|
|
wtWebio577xxEA12x12SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebio577xxEA12x12SNMP 4 }
|
|
|
|
wtWebio577xxEA12x12SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebio577xxEA12x12SNMP 5 }
|
|
|
|
wtWebio577xxEA12x12SnmpSystemTrapManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the system trap."
|
|
::= { wtWebio577xxEA12x12SNMP 6 }
|
|
|
|
-- wtWebio577xxEA12x12UDP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebio577xxEA12x12UDP 1 }
|
|
|
|
wtWebio577xxEA12x12UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebio577xxEA12x12UDP 2 }
|
|
|
|
wtWebio577xxEA12x12UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebio577xxEA12x12UDP 3 }
|
|
|
|
-- wtWebio577xxEA12x12Binary Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12BinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebio577xxEA12x12Binary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebio577xxEA12x12BinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebio577xxEA12x12Binary 2 }
|
|
|
|
wtWebio577xxEA12x12BinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebio577xxEA12x12BinaryModeNo }
|
|
::= { wtWebio577xxEA12x12BinaryIfTable 1 }
|
|
|
|
WtWebio577xxEA12x12BinaryIfEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12BinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA12x12BinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebio577xxEA12x12BinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12BinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebio577xxEA12x12Binary 3 }
|
|
|
|
wtWebio577xxEA12x12BinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebio577xxEA12x12BinaryModeNo }
|
|
::= { wtWebio577xxEA12x12BinaryTable 1 }
|
|
|
|
WtWebio577xxEA12x12BinaryEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12BinaryOperationMode OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryTcpServerLocalPort INTEGER,
|
|
wtWebio577xxEA12x12BinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryTcpClientLocalPort INTEGER,
|
|
wtWebio577xxEA12x12BinaryTcpClientServerPort INTEGER,
|
|
wtWebio577xxEA12x12BinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryTcpClientInactivity INTEGER,
|
|
wtWebio577xxEA12x12BinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryTcpClientInterval INTEGER,
|
|
wtWebio577xxEA12x12BinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryUdpPeerLocalPort INTEGER,
|
|
wtWebio577xxEA12x12BinaryUdpPeerRemotePort INTEGER,
|
|
wtWebio577xxEA12x12BinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryUdpPeerInterval INTEGER,
|
|
wtWebio577xxEA12x12BinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebio577xxEA12x12BinaryConnectedPort INTEGER,
|
|
wtWebio577xxEA12x12BinaryConnectedIpAddr IpAddress,
|
|
wtWebio577xxEA12x12BinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebio577xxEA12x12BinaryTcpClientServerHttpPort INTEGER,
|
|
wtWebio577xxEA12x12BinaryTcpClientServerUserName OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x12BinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebio577xxEA12x12BinaryEntry 1 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 2 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA12x12BinaryEntry 3 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA12x12BinaryEntry 4 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 5 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 6 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 7 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 8 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 9 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA12x12BinaryEntry 10 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 11 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA12x12BinaryEntry 12 }
|
|
|
|
wtWebio577xxEA12x12BinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 13 }
|
|
|
|
wtWebio577xxEA12x12BinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 14 }
|
|
|
|
wtWebio577xxEA12x12BinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 15 }
|
|
|
|
wtWebio577xxEA12x12BinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3: Digital inputs 8-11
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebio577xxEA12x12BinaryEntry 16 }
|
|
|
|
wtWebio577xxEA12x12BinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 17 }
|
|
|
|
wtWebio577xxEA12x12BinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA12x12BinaryEntry 18 }
|
|
|
|
wtWebio577xxEA12x12BinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 19 }
|
|
|
|
wtWebio577xxEA12x12BinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 20 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 21 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 22 }
|
|
|
|
wtWebio577xxEA12x12BinaryTcpClientServerUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Name to login at the remote server, if authentication needed."
|
|
::= { wtWebio577xxEA12x12BinaryEntry 23 }
|
|
|
|
|
|
-- wtWebio577xxEA12x12Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebio577xxEA12x12Syslog 1 }
|
|
|
|
wtWebio577xxEA12x12SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebio577xxEA12x12Syslog 2 }
|
|
|
|
wtWebio577xxEA12x12SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebio577xxEA12x12Syslog 3 }
|
|
|
|
wtWebio577xxEA12x12SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebio577xxEA12x12Syslog 4 }
|
|
|
|
-- wtWebio577xxEA12x12FTP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebio577xxEA12x12FTP 1 }
|
|
|
|
wtWebio577xxEA12x12FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebio577xxEA12x12FTP 2 }
|
|
|
|
wtWebio577xxEA12x12FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebio577xxEA12x12FTP 3 }
|
|
|
|
wtWebio577xxEA12x12FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebio577xxEA12x12FTP 4 }
|
|
|
|
wtWebio577xxEA12x12FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebio577xxEA12x12FTP 5 }
|
|
|
|
wtWebio577xxEA12x12FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebio577xxEA12x12FTP 6 }
|
|
|
|
wtWebio577xxEA12x12FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebio577xxEA12x12FTP 7 }
|
|
|
|
-- wtWebio577xxEA12x12MQTT Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12MQTTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 7 enables MQTT:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0-6: unused
|
|
Bit 7 : MQTT enable"
|
|
::= { wtWebio577xxEA12x12MQTT 1 }
|
|
|
|
wtWebio577xxEA12x12MQTTBrockerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP-address of the MQTT-Server."
|
|
::= { wtWebio577xxEA12x12MQTT 2 }
|
|
|
|
wtWebio577xxEA12x12MQTTUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login user name."
|
|
::= { wtWebio577xxEA12x12MQTT 3 }
|
|
|
|
wtWebio577xxEA12x12MQTTPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login password."
|
|
::= { wtWebio577xxEA12x12MQTT 4 }
|
|
|
|
wtWebio577xxEA12x12MQTTLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local port number."
|
|
::= { wtWebio577xxEA12x12MQTT 5 }
|
|
|
|
wtWebio577xxEA12x12MQTTBrokerServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Server port number."
|
|
::= { wtWebio577xxEA12x12MQTT 6 }
|
|
|
|
wtWebio577xxEA12x12MQTTInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ping intervall, if no data has to be send: time in seconds."
|
|
::= { wtWebio577xxEA12x12MQTT 7 }
|
|
|
|
wtWebio577xxEA12x12MQTTLastWillEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will enable"
|
|
::= { wtWebio577xxEA12x12MQTT 8 }
|
|
|
|
wtWebio577xxEA12x12MQTTLastWillTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Topic."
|
|
::= { wtWebio577xxEA12x12MQTT 9 }
|
|
|
|
wtWebio577xxEA12x12MQTTLastWillMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will message."
|
|
::= { wtWebio577xxEA12x12MQTT 10 }
|
|
|
|
wtWebio577xxEA12x12MQTTLastWillQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish QoS:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebio577xxEA12x12MQTT 11 }
|
|
|
|
wtWebio577xxEA12x12MQTTLastWillRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish Retain properties:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA12x12MQTT 12 }
|
|
|
|
wtWebio577xxEA12x12MQTTLastWillConnectEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill Connect message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will connect message enable"
|
|
::= { wtWebio577xxEA12x12MQTT 13 }
|
|
|
|
wtWebio577xxEA12x12MQTTLastWillConnectMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Connect message will be send with the QoS and Retain settings
|
|
of the LastWill message."
|
|
::= { wtWebio577xxEA12x12MQTT 14 }
|
|
|
|
|
|
-- wtWebio577xxEA1x1REST Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x12RESTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates REST:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : REST enable"
|
|
::= { wtWebio577xxEA12x12REST 1 }
|
|
|
|
wtWebio577xxEA12x12RESTDigestAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates Digest-Authentification:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Digest Auth enable"
|
|
::= { wtWebio577xxEA12x12REST 2 }
|
|
|
|
-- wtWebio577xxEA12x12OutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebio577xxEA12x12OutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebio577xxEA12x12OutputMode 1 }
|
|
|
|
wtWebio577xxEA12x12OutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebio577xxEA12x12OutputNo }
|
|
::= { wtWebio577xxEA12x12OutputModeTable 1 }
|
|
|
|
WtWebio577xxEA12x12OutputModeEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12OutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebio577xxEA12x12OutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebio577xxEA12x12OutputModeEntry 1 }
|
|
|
|
wtWebio577xxEA12x12SafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebio577xxEA12x12OutputMode 2 }
|
|
|
|
-- wtWebio577xxEA12x12Alarm Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x12AlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebio577xxEA12x12Alarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebio577xxEA12x12AlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebio577xxEA12x12Alarm 2 }
|
|
|
|
wtWebio577xxEA12x12AlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebio577xxEA12x12AlarmNo }
|
|
::= { wtWebio577xxEA12x12AlarmIfTable 1 }
|
|
|
|
WtWebio577xxEA12x12AlarmIfEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12AlarmNo INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA12x12AlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebio577xxEA12x12AlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebio577xxEA12x12AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebio577xxEA12x12Alarm 3 }
|
|
|
|
wtWebio577xxEA12x12AlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebio577xxEA12x12AlarmNo }
|
|
::= { wtWebio577xxEA12x12AlarmTable 1 }
|
|
|
|
WtWebio577xxEA12x12AlarmEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12AlarmInputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmOutputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSystemTrigger OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmMaxCounterValue OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmInterval OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmEnable OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmMailAddr OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmMailSubject OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmMailText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSnmpManagerIP OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSnmpTrapText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmUdpIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmUdpPort INTEGER,
|
|
wtWebio577xxEA12x12AlarmUdpText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmTcpIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmTcpPort INTEGER,
|
|
wtWebio577xxEA12x12AlarmTcpText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSyslogIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSyslogPort INTEGER,
|
|
wtWebio577xxEA12x12AlarmSyslogText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmFtpDataPort OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmFtpFileName OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmFtpText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmFtpOption OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmTimerCron OCTET STRING,
|
|
|
|
wtWebio577xxEA12x12AlarmMailReleaseSubject OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmMailReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmUdpReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmTcpReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSyslogReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmFtpReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmGlobalEnable OCTET STRING,
|
|
|
|
wtWebio577xxEA12x12AlarmCombinationLogic OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmTrgMqttTopic OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmTrgMqttTopicText OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmHttpReqAuthEnable OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmHttpReqAuthUser OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmHttpReqAuthPassword OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmHttpReqSetUrl OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmHttpReqClearUrl OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmHttpReqServerPort INTEGER,
|
|
wtWebio577xxEA12x12AlarmMqttTopicPath OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmMqttTopicSetTopic OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmMqttTopicClear OCTET STRING,
|
|
|
|
wtWebio577xxEA12x12AlarmSetOutputsOwn OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSetOutputsServerIp OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSetOutputsServerPort INTEGER,
|
|
wtWebio577xxEA12x12AlarmSetOutputsServerPassword OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSetOutputsServerOutputs OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmSetOutputsDest OCTET STRING,
|
|
|
|
wtWebio577xxEA12x12AlarmSnmpManagerPort INTEGER,
|
|
wtWebio577xxEA12x12AlarmMqttQoS OCTET STRING,
|
|
wtWebio577xxEA12x12AlarmMqttRetain OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x12AlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3, Bit 0-3: Mask for digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Mask for digital inputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7, Bit 0-3: Level of digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 8, Bit 0-7: Level of digital inputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unsused
|
|
OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11
|
|
Bit 12-15 : unused
|
|
OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 1 }
|
|
|
|
wtWebio577xxEA12x12AlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3, Bit 0-3: Mask for digital outputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7, Bit 0-3: Level of digital outputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 8, Bit 0-7: Level of digital outputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11
|
|
Bit 12-15 : unused
|
|
OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7"
|
|
|
|
::= { wtWebio577xxEA12x12AlarmEntry 2 }
|
|
|
|
wtWebio577xxEA12x12AlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 3 }
|
|
|
|
wtWebio577xxEA12x12AlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebio577xxEA12x12AlarmInputTrigger are not considered."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 4 }
|
|
|
|
wtWebio577xxEA12x12AlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 5 }
|
|
|
|
wtWebio577xxEA12x12AlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Bit 0: UDP enable
|
|
Bit1-7: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: TCP Client enable
|
|
Bit 3: Syslog Messages enable
|
|
Bit 4: FTP enable
|
|
Bit 5: HTTP Request enable
|
|
Bit 6 MQTT Publish enable
|
|
Bit 7: Set Outputs"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 6 }
|
|
|
|
wtWebio577xxEA12x12AlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 7 }
|
|
|
|
wtWebio577xxEA12x12AlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 8 }
|
|
|
|
wtWebio577xxEA12x12AlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 9 }
|
|
|
|
wtWebio577xxEA12x12AlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 10 }
|
|
|
|
wtWebio577xxEA12x12AlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 11 }
|
|
|
|
wtWebio577xxEA12x12AlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 12 }
|
|
|
|
wtWebio577xxEA12x12AlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 13 }
|
|
|
|
wtWebio577xxEA12x12AlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 14 }
|
|
|
|
wtWebio577xxEA12x12AlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 15 }
|
|
|
|
wtWebio577xxEA12x12AlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 16 }
|
|
|
|
wtWebio577xxEA12x12AlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 17 }
|
|
|
|
wtWebio577xxEA12x12AlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 18 }
|
|
|
|
wtWebio577xxEA12x12AlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 19 }
|
|
|
|
wtWebio577xxEA12x12AlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 20 }
|
|
|
|
wtWebio577xxEA12x12AlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 21 }
|
|
|
|
wtWebio577xxEA12x12AlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 22 }
|
|
|
|
wtWebio577xxEA12x12AlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 23 }
|
|
|
|
wtWebio577xxEA12x12AlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 24 }
|
|
|
|
wtWebio577xxEA12x12AlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 25 }
|
|
|
|
wtWebio577xxEA12x12AlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 26 }
|
|
|
|
wtWebio577xxEA12x12AlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 27 }
|
|
|
|
wtWebio577xxEA12x12AlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 28 }
|
|
|
|
wtWebio577xxEA12x12AlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 29 }
|
|
|
|
wtWebio577xxEA12x12AlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 30 }
|
|
|
|
wtWebio577xxEA12x12AlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 31 }
|
|
|
|
wtWebio577xxEA12x12AlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 32 }
|
|
|
|
wtWebio577xxEA12x12AlarmGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Alarm enable"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 34 }
|
|
|
|
wtWebio577xxEA12x12AlarmCombinationLogic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded logic, all Input/Output-trigger will be combined:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : OR
|
|
Bit 0 : AND"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 58 }
|
|
|
|
wtWebio577xxEA12x12AlarmTrgMqttTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT subscribe topic."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 59 }
|
|
|
|
|
|
wtWebio577xxEA12x12AlarmTrgMqttTopicText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Receiving this text from the MQTT Broker, Alarm will be triggered."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 60 }
|
|
|
|
wtWebio577xxEA12x12AlarmHttpReqAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : HHTP Request Authentication enable"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 61 }
|
|
|
|
wtWebio577xxEA12x12AlarmHttpReqAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: User"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 62 }
|
|
|
|
wtWebio577xxEA12x12AlarmHttpReqAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Password"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 63 }
|
|
|
|
wtWebio577xxEA12x12AlarmHttpReqSetUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Set URL"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 64 }
|
|
|
|
wtWebio577xxEA12x12AlarmHttpReqClearUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Clear URL"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 65 }
|
|
|
|
wtWebio577xxEA12x12AlarmHttpReqServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Server Port"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 66 }
|
|
|
|
wtWebio577xxEA12x12AlarmMqttTopicPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic path"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 67 }
|
|
|
|
wtWebio577xxEA12x12AlarmMqttTopicSetTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic SET message"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 68 }
|
|
|
|
wtWebio577xxEA12x12AlarmMqttTopicClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic CLEAR message"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 69 }
|
|
|
|
wtWebio577xxEA12x12AlarmSetOutputsOwn OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : Bit 0-3: Level of digital outputs 8-11
|
|
OCTET 4 : Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : Bit 0-3: Level of digital outputs 8-11
|
|
OCTET 8 : Bit 0-7: Level of digital outputs 0-7
|
|
|
|
OCTETS 9-12 are unused."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 70 }
|
|
|
|
wtWebio577xxEA12x12AlarmSetOutputsServerIp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server IP Address"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 71 }
|
|
|
|
wtWebio577xxEA12x12AlarmSetOutputsServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server Port"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 72 }
|
|
|
|
wtWebio577xxEA12x12AlarmSetOutputsServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server Pasword"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 73 }
|
|
|
|
wtWebio577xxEA12x12AlarmSetOutputsServerOutputs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : Bit 0-3: Level of digital outputs 8-11
|
|
OCTET 4 : Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : Bit 0-3: Level of digital outputs 8-11
|
|
OCTET 8 : Bit 0-7: Level of digital outputs 0-7
|
|
|
|
OCTETS 9-12 are unused."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 74 }
|
|
|
|
wtWebio577xxEA12x12AlarmSetOutputsDest OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Bit 0 = LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : set outputs of remote server.
|
|
Bit 0 : set outputs of this WEB-IO"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 75 }
|
|
|
|
wtWebio577xxEA12x12AlarmSnmpManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebio577xxEA12x12AlarmEntry 76 }
|
|
|
|
wtWebio577xxEA12x12AlarmMqttQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 77 }
|
|
|
|
wtWebio577xxEA12x12AlarmMqttRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA12x12AlarmEntry 78 }
|
|
|
|
-- wtWebio577xxEA12x12LoadControl
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x12LoadControlView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of automatic load control can be read. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: Bit 0-3: outputs 8-11
|
|
Octet 4: Bit 0-7: outputs 0-7."
|
|
::= { wtWebio577xxEA12x12Alarm 4 }
|
|
|
|
wtWebio577xxEA12x12LCShutDownView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of the automatic load control shut down can be read. All outputs remain switched of,
|
|
until a zero is written into this variable. But previously all loads should be inspected.
|
|
High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason.
|
|
If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair.
|
|
All controlled output could be identified reading the variable wtWebio577xxEA12x12LoadControlEnable.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: Bit 0-3: outputs 8-11
|
|
Octet 4: Bit 0-7: outputs 0-7."
|
|
::= { wtWebio577xxEA12x12Alarm 5 }
|
|
|
|
-- wtWebio577xxEA12x12Ports Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebio577xxEA12x12InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebio577xxEA12x12Ports 1 }
|
|
|
|
wtWebio577xxEA12x12InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebio577xxEA12x12InputNo }
|
|
::= { wtWebio577xxEA12x12InputPortTable 1 }
|
|
|
|
WtWebio577xxEA12x12InputPortEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12PortInputName OCTET STRING,
|
|
wtWebio577xxEA12x12PortInputText OCTET STRING,
|
|
wtWebio577xxEA12x12PortInputMode OCTET STRING,
|
|
wtWebio577xxEA12x12PortInputFilter INTEGER,
|
|
wtWebio577xxEA12x12PortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebio577xxEA12x12PortInputBicountInactivTimeout INTEGER
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x12PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebio577xxEA12x12InputPortEntry 1 }
|
|
|
|
wtWebio577xxEA12x12PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebio577xxEA12x12InputPortEntry 2 }
|
|
|
|
wtWebio577xxEA12x12PortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable"
|
|
::= { wtWebio577xxEA12x12InputPortEntry 3 }
|
|
|
|
wtWebio577xxEA12x12PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebio577xxEA12x12InputPortEntry 4 }
|
|
|
|
wtWebio577xxEA12x12PortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA12x12InputPortEntry 5 }
|
|
|
|
wtWebio577xxEA12x12PortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebio577xxEA12x12InputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebio577xxEA12x12OutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x12OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebio577xxEA12x12Ports 2 }
|
|
|
|
wtWebio577xxEA12x12OutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x12OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebio577xxEA12x12OutputNo }
|
|
::= { wtWebio577xxEA12x12OutputPortTable 1 }
|
|
|
|
WtWebio577xxEA12x12OutputPortEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x12PortOutputName OCTET STRING,
|
|
wtWebio577xxEA12x12PortOutputText OCTET STRING,
|
|
wtWebio577xxEA12x12PortOutputGroupMode OCTET STRING,
|
|
wtWebio577xxEA12x12PortOutputSafetyState OCTET STRING,
|
|
wtWebio577xxEA12x12PortLogicInputMask OCTET STRING,
|
|
wtWebio577xxEA12x12PortLogicInputInverter OCTET STRING,
|
|
wtWebio577xxEA12x12PortLogicFunction OCTET STRING,
|
|
wtWebio577xxEA12x12PortLogicOutputInverter OCTET STRING,
|
|
wtWebio577xxEA12x12PortPulseDuration INTEGER,
|
|
wtWebio577xxEA12x12PortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x12PortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 1 }
|
|
|
|
wtWebio577xxEA12x12PortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 2 }
|
|
|
|
wtWebio577xxEA12x12PortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one output bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for outputs 0-3:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default)
|
|
Bit 1 : outputs 0+1, 2+3 connected
|
|
Bit 2 : outputs 0+1+2+3 connected
|
|
Bit 3-7 : unused
|
|
Selection for outputs 4-7:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default)
|
|
Bit 1 : outputs 4+5, 6+7 connected
|
|
Bit 2 : outputs 4+5+6+7 connected
|
|
Bit 3-7 : unused
|
|
Selection for outputs 8-11:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default)
|
|
Bit 1 : outputs 8+9, 10+11 connected
|
|
Bit 2 : outputs 8+9+10+11 connected
|
|
Bit 3-7 : unused"
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 3 }
|
|
|
|
wtWebio577xxEA12x12PortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 Bit 4-7: unused
|
|
Bit 0-3: Mask for digital output 8-11
|
|
OCTET 4 Bit 0-7: Mask for digital output 0-7
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 Bit 4-7: Unused
|
|
Bit 0-3: Level of digital output 8-11
|
|
OCTET 8 Bit 0-7: Level of digital output 0-7"
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 4 }
|
|
|
|
wtWebio577xxEA12x12PortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebio577xxEA12x12PortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebio577xxEA12x12PortLogicInputInverter)
|
|
3. Logical combination (wtWebio577xxEA12x12PortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebio577xxEA12x12PortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : inputs 8-11
|
|
OCTET 4: Bit 0-7 : inputs 0-7"
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 5 }
|
|
|
|
wtWebio577xxEA12x12PortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : inputs 8-11
|
|
OCTET 4: Bit 0-7 : inputs 0-7"
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 6 }
|
|
|
|
wtWebio577xxEA12x12PortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 7 }
|
|
|
|
wtWebio577xxEA12x12PortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : Output Inverter enable 8-11
|
|
OCTET 4: Bit 0-7 : Output Inverter enable 0-7"
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 8 }
|
|
|
|
wtWebio577xxEA12x12PortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 9 }
|
|
|
|
wtWebio577xxEA12x12PortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebio577xxEA12x12PortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA12x12OutputPortEntry 10 }
|
|
|
|
-- wtWebio577xxEA12x12Manufact Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x12MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebio577xxEA12x12Manufact 1 }
|
|
|
|
wtWebio577xxEA12x12MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebio577xxEA12x12Manufact 2 }
|
|
|
|
wtWebio577xxEA12x12MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebio577xxEA12x12Manufact 3 }
|
|
|
|
wtWebio577xxEA12x12MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebio577xxEA12x12Manufact 4 }
|
|
|
|
wtWebio577xxEA12x12MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebio577xxEA12x12Manufact 5 }
|
|
|
|
-- wtWebio577xxEA12x12Diag Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x12DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebio577xxEA12x12Diag 1 }
|
|
|
|
wtWebio577xxEA12x12DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebio577xxEA12x12Diag 2 }
|
|
|
|
wtWebio577xxEA12x12DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebio577xxEA12x12DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebio577xxEA12x12DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebio577xxEA12x12DiagErrorMessage."
|
|
::= { wtWebio577xxEA12x12Diag 3 }
|
|
|
|
wtWebio577xxEA12x12DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebio577xxEA12x12DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebio577xxEA12x12Diag 4 }
|
|
|
|
wtWebio577xxEA12x12DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebio577xxEA12x12Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebio577xxEA12x12Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebio577xxEA12x12Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebio577xxEA12x12Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebio577xxEA12x12Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebio577xxEA12x12Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebio577xxEA12x12Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebio577xxEA12x12Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebio577xxEA12x12Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebio577xxEA12x12Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebio577xxEA12x12Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebio577xxEA12x12Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebio577xxEA12x12Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebio577xxEA12x12Alert13 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebio577xxEA12x12Alert14 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebio577xxEA12x12Alert15 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebio577xxEA12x12Alert16 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebio577xxEA12x12Alert17 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebio577xxEA12x12Alert18 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebio577xxEA12x12Alert19 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebio577xxEA12x12Alert20 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebio577xxEA12x12Alert21 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebio577xxEA12x12Alert22 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebio577xxEA12x12Alert23 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebio577xxEA12x12Alert24 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES { wtWebio577xxEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebio577xxEA12x12AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x12
|
|
VARIABLES {
|
|
wtWebio577xxEA12x12DiagErrorIndex,
|
|
wtWebio577xxEA12x12DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebioEA12x12InOut Group
|
|
------------------------
|
|
|
|
wtWebioEA12x12Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebioEA12x12InOut 1 }
|
|
|
|
wtWebioEA12x12Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebioEA12x12InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA12x12InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA12x12InOut 3 }
|
|
|
|
wtWebioEA12x12InputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebioEA12x12InputNo }
|
|
::= { wtWebioEA12x12InputTable 1 }
|
|
|
|
WtWebioEA12x12InputEntry ::= SEQUENCE {
|
|
wtWebioEA12x12InputNo INTEGER,
|
|
wtWebioEA12x12InputCounter INTEGER,
|
|
wtWebioEA12x12InputCounterClear INTEGER,
|
|
wtWebioEA12x12InputState INTEGER
|
|
}
|
|
|
|
wtWebioEA12x12InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA12x12InputEntry 1 }
|
|
|
|
wtWebioEA12x12InputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA12x12InputEntry 2 }
|
|
|
|
wtWebioEA12x12InputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebioEA12x12InputEntry 3 }
|
|
|
|
wtWebioEA12x12InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA12x12InputEntry 4 }
|
|
|
|
wtWebioEA12x12InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital outputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital outputs 0-7"
|
|
::= { wtWebioEA12x12InOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA12x12OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA12x12InOut 5 }
|
|
|
|
wtWebioEA12x12OutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebioEA12x12OutputNo }
|
|
::= { wtWebioEA12x12OutputTable 1 }
|
|
|
|
WtWebioEA12x12OutputEntry ::= SEQUENCE {
|
|
wtWebioEA12x12OutputNo INTEGER,
|
|
wtWebioEA12x12OutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA12x12OutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebioEA12x12OutputEntry 1 }
|
|
|
|
wtWebioEA12x12OutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA12x12OutputEntry 2 }
|
|
|
|
wtWebioEA12x12OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital outputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital outputs 0-7"
|
|
::= { wtWebioEA12x12InOut 6 }
|
|
|
|
wtWebioEA12x12SetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3, Bit 0-3: Mask for digital outputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7, Bit 0-3: Level of digital outputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 8, Bit 0-7: Level of digital outputs 0-7"
|
|
::= { wtWebioEA12x12InOut 7 }
|
|
|
|
-- wtWebioEA12x12SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA12x12SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA12x12SessCntrl 1 }
|
|
|
|
wtWebioEA12x12SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA12x12SessCntrl 2 }
|
|
|
|
wtWebioEA12x12SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA12x12SessCntrl 3 }
|
|
|
|
wtWebioEA12x12SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA12x12SessCntrl 4 }
|
|
|
|
wtWebioEA12x12SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA12x12SessCntrl 5 }
|
|
|
|
-- wtWebioEA12x12Text Group
|
|
------------------------
|
|
|
|
wtWebioEA12x12DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA12x12Text 1 }
|
|
|
|
wtWebioEA12x12DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA12x12Text 2 }
|
|
|
|
wtWebioEA12x12DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA12x12Text 3 }
|
|
|
|
wtWebioEA12x12DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA12x12Text 4 }
|
|
|
|
-- wtWebioEA12x12TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x12TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA12x12TimeZone 1 }
|
|
|
|
wtWebioEA12x12TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA12x12TimeZone 2 }
|
|
|
|
wtWebioEA12x12TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA12x12TimeZone 3 }
|
|
|
|
wtWebioEA12x12StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA12x12TimeZone 4 }
|
|
|
|
wtWebioEA12x12StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA12x12TimeZone 5 }
|
|
|
|
wtWebioEA12x12StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA12x12TimeZone 6 }
|
|
|
|
wtWebioEA12x12StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x12StartMonth-January(1),
|
|
wtWebioEA12x12StartMonth-February(2),
|
|
wtWebioEA12x12StartMonth-March(3),
|
|
wtWebioEA12x12StartMonth-April(4),
|
|
wtWebioEA12x12StartMonth-May(5),
|
|
wtWebioEA12x12StartMonth-June(6),
|
|
wtWebioEA12x12StartMonth-July(7),
|
|
wtWebioEA12x12StartMonth-August(8),
|
|
wtWebioEA12x12StartMonth-September(9),
|
|
wtWebioEA12x12StartMonth-October(10),
|
|
wtWebioEA12x12StartMonth-November(11),
|
|
wtWebioEA12x12StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA12x12TimeZone 7 }
|
|
|
|
wtWebioEA12x12StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x12StartMode-first(1),
|
|
wtWebioEA12x12StartMode-second(2),
|
|
wtWebioEA12x12StartMode-third(3),
|
|
wtWebioEA12x12StartMode-fourth(4),
|
|
wtWebioEA12x12StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA12x12TimeZone 8 }
|
|
|
|
wtWebioEA12x12StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x12StartWday-Sunday(1),
|
|
wtWebioEA12x12StartWday-Monday(2),
|
|
wtWebioEA12x12StartWday-Tuesday(3),
|
|
wtWebioEA12x12StartWday-Thursday(4),
|
|
wtWebioEA12x12StartWday-Wednesday(5),
|
|
wtWebioEA12x12StartWday-Friday(6),
|
|
wtWebioEA12x12StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA12x12TimeZone 9 }
|
|
|
|
wtWebioEA12x12StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x12TimeZone 10 }
|
|
|
|
wtWebioEA12x12StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x12TimeZone 11 }
|
|
|
|
wtWebioEA12x12StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x12StopMonth-January(1),
|
|
wtWebioEA12x12StopMonth-February(2),
|
|
wtWebioEA12x12StopMonth-March(3),
|
|
wtWebioEA12x12StopMonth-April(4),
|
|
wtWebioEA12x12StopMonth-May(5),
|
|
wtWebioEA12x12StopMonth-June(6),
|
|
wtWebioEA12x12StopMonth-July(7),
|
|
wtWebioEA12x12StopMonth-August(8),
|
|
wtWebioEA12x12StopMonth-September(9),
|
|
wtWebioEA12x12StopMonth-October(10),
|
|
wtWebioEA12x12StopMonth-November(11),
|
|
wtWebioEA12x12StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x12TimeZone 12 }
|
|
|
|
wtWebioEA12x12StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x12StopMode-first(1),
|
|
wtWebioEA12x12StopMode-second(2),
|
|
wtWebioEA12x12StopMode-third(3),
|
|
wtWebioEA12x12StopMode-fourth(4),
|
|
wtWebioEA12x12StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x12TimeZone 13 }
|
|
|
|
wtWebioEA12x12StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x12StopWday-Sunday(1),
|
|
wtWebioEA12x12StopWday-Monday(2),
|
|
wtWebioEA12x12StopWday-Tuesday(3),
|
|
wtWebioEA12x12StopWday-Thursday(4),
|
|
wtWebioEA12x12StopWday-Wednesday(5),
|
|
wtWebioEA12x12StopWday-Friday(6),
|
|
wtWebioEA12x12StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x12TimeZone 14 }
|
|
|
|
wtWebioEA12x12StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x12TimeZone 15 }
|
|
|
|
wtWebioEA12x12StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x12TimeZone 16 }
|
|
|
|
-- wtWebioEA12x12TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x12TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA12x12TimeServer 1 }
|
|
|
|
wtWebioEA12x12TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA12x12TimeServer 2 }
|
|
|
|
wtWebioEA12x12TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA12x12TimeServer 3 }
|
|
|
|
wtWebioEA12x12TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA12x12TimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA12x12DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x12ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA12x12DeviceClock 1 }
|
|
|
|
wtWebioEA12x12ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA12x12DeviceClock 2 }
|
|
|
|
wtWebioEA12x12ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA12x12DeviceClock 3 }
|
|
|
|
wtWebioEA12x12ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x12ClockMonth-January(1),
|
|
wtWebioEA12x12ClockMonth-February(2),
|
|
wtWebioEA12x12ClockMonth-March(3),
|
|
wtWebioEA12x12ClockMonth-April(4),
|
|
wtWebioEA12x12ClockMonth-May(5),
|
|
wtWebioEA12x12ClockMonth-June(6),
|
|
wtWebioEA12x12ClockMonth-July(7),
|
|
wtWebioEA12x12ClockMonth-August(8),
|
|
wtWebioEA12x12ClockMonth-September(9),
|
|
wtWebioEA12x12ClockMonth-October(10),
|
|
wtWebioEA12x12ClockMonth-November(11),
|
|
wtWebioEA12x12ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA12x12DeviceClock 4 }
|
|
|
|
wtWebioEA12x12ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA12x12DeviceClock 5 }
|
|
|
|
-- wtWebioEA12x12Network Group
|
|
------------------------
|
|
|
|
wtWebioEA12x12IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA12x12Network 1 }
|
|
|
|
wtWebioEA12x12SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA12x12Network 2 }
|
|
|
|
wtWebioEA12x12Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA12x12Network 3 }
|
|
|
|
wtWebioEA12x12DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA12x12Network 4 }
|
|
|
|
wtWebioEA12x12DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA12x12Network 5 }
|
|
|
|
wtWebioEA12x12AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA12x12Network 6 }
|
|
|
|
-- wtWebioEA12x12HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12Startup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA12x12HTTP 1 }
|
|
|
|
wtWebioEA12x12GetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA12x12HTTP 2 }
|
|
|
|
wtWebioEA12x12HttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x12HTTP 3 }
|
|
|
|
wtWebioEA12x12HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA12x12HTTP 4 }
|
|
|
|
|
|
-- wtWebioEA12x12Mail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA12x12Mail 1 }
|
|
|
|
wtWebioEA12x12MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA12x12Mail 2 }
|
|
|
|
wtWebioEA12x12MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA12x12Mail 3 }
|
|
|
|
wtWebioEA12x12MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA12x12Mail 4 }
|
|
|
|
wtWebioEA12x12MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA12x12Mail 5 }
|
|
|
|
wtWebioEA12x12MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA12x12Mail 6 }
|
|
|
|
wtWebioEA12x12MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA12x12Mail 7 }
|
|
|
|
wtWebioEA12x12MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA12x12Mail 8 }
|
|
|
|
|
|
-- wtWebioEA12x12Snmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA12x12SNMP 1 }
|
|
|
|
wtWebioEA12x12SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA12x12SNMP 2 }
|
|
|
|
wtWebioEA12x12SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA12x12SNMP 3 }
|
|
|
|
wtWebioEA12x12SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA12x12SNMP 4 }
|
|
|
|
wtWebioEA12x12SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA12x12SNMP 5 }
|
|
|
|
-- wtWebioEA12x12Udp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA12x12UDP 1 }
|
|
|
|
wtWebioEA12x12UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA12x12UDP 2 }
|
|
|
|
wtWebioEA12x12UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA12x12UDP 3 }
|
|
|
|
-- wtWebioEA12x12Binary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12BinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA12x12Binary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA12x12BinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA12x12Binary 2 }
|
|
|
|
wtWebioEA12x12BinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA12x12BinaryModeNo }
|
|
::= { wtWebioEA12x12BinaryIfTable 1 }
|
|
|
|
WtWebioEA12x12BinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA12x12BinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA12x12BinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA12x12BinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12BinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA12x12Binary 3 }
|
|
|
|
wtWebioEA12x12BinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA12x12BinaryModeNo }
|
|
::= { wtWebioEA12x12BinaryTable 1 }
|
|
|
|
WtWebioEA12x12BinaryEntry ::= SEQUENCE {
|
|
wtWebioEA12x12BinaryOperationMode OCTET STRING,
|
|
wtWebioEA12x12BinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA12x12BinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA12x12BinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA12x12BinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA12x12BinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA12x12BinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA12x12BinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA12x12BinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA12x12BinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA12x12BinaryTcpClientInterval INTEGER,
|
|
wtWebioEA12x12BinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA12x12BinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA12x12BinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA12x12BinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA12x12BinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA12x12BinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA12x12BinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA12x12BinaryConnectedPort INTEGER,
|
|
wtWebioEA12x12BinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA12x12BinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA12x12BinaryTcpClientServerHttpPort INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA12x12BinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA12x12BinaryEntry 1 }
|
|
|
|
wtWebioEA12x12BinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x12BinaryEntry 2 }
|
|
|
|
wtWebioEA12x12BinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x12BinaryEntry 3 }
|
|
|
|
wtWebioEA12x12BinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x12BinaryEntry 4 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x12BinaryEntry 5 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA12x12BinaryEntry 6 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA12x12BinaryEntry 7 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA12x12BinaryEntry 8 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA12x12BinaryEntry 9 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x12BinaryEntry 10 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA12x12BinaryEntry 11 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x12BinaryEntry 12 }
|
|
|
|
wtWebioEA12x12BinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x12BinaryEntry 13 }
|
|
|
|
wtWebioEA12x12BinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA12x12BinaryEntry 14 }
|
|
|
|
wtWebioEA12x12BinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA12x12BinaryEntry 15 }
|
|
|
|
wtWebioEA12x12BinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x12BinaryEntry 16 }
|
|
|
|
wtWebioEA12x12BinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA12x12BinaryEntry 17 }
|
|
|
|
wtWebioEA12x12BinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x12BinaryEntry 18 }
|
|
|
|
wtWebioEA12x12BinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA12x12BinaryEntry 19 }
|
|
|
|
wtWebioEA12x12BinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA12x12BinaryEntry 20 }
|
|
|
|
wtWebioEA12x12BinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA12x12BinaryEntry 21 }
|
|
|
|
wtWebioEA12x12BinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA12x12BinaryEntry 22 }
|
|
|
|
-- wtWebioEA12x12Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA12x12Syslog 1 }
|
|
|
|
wtWebioEA12x12SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA12x12Syslog 2 }
|
|
|
|
wtWebioEA12x12SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA12x12Syslog 3 }
|
|
|
|
wtWebioEA12x12SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA12x12Syslog 4 }
|
|
|
|
-- wtWebioEA12x12FTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x12FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA12x12FTP 1 }
|
|
|
|
wtWebioEA12x12FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA12x12FTP 2 }
|
|
|
|
wtWebioEA12x12FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA12x12FTP 3 }
|
|
|
|
wtWebioEA12x12FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA12x12FTP 4 }
|
|
|
|
wtWebioEA12x12FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA12x12FTP 5 }
|
|
|
|
wtWebioEA12x12FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA12x12FTP 6 }
|
|
|
|
wtWebioEA12x12FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA12x12FTP 7 }
|
|
|
|
-- wtWebioEA12x12OutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA12x12OutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA12x12OutputMode 1 }
|
|
|
|
wtWebioEA12x12OutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA12x12OutputNo }
|
|
::= { wtWebioEA12x12OutputModeTable 1 }
|
|
|
|
WtWebioEA12x12OutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA12x12OutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA12x12OutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA12x12OutputModeEntry 1 }
|
|
|
|
wtWebioEA12x12SafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA12x12OutputMode 2 }
|
|
|
|
wtWebioEA12x12LoadControlEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the function of automatic load control can be enabled. All output were tested in
|
|
pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Load Control enable"
|
|
::= { wtWebioEA12x12OutputMode 3 }
|
|
|
|
-- wtWebioEA12x12Alarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x12AlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA12x12Alarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA12x12AlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA12x12Alarm 2 }
|
|
|
|
wtWebioEA12x12AlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA12x12AlarmNo }
|
|
::= { wtWebioEA12x12AlarmIfTable 1 }
|
|
|
|
WtWebioEA12x12AlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA12x12AlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA12x12AlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA12x12AlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA12x12AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA12x12Alarm 3 }
|
|
|
|
wtWebioEA12x12AlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA12x12AlarmNo }
|
|
::= { wtWebioEA12x12AlarmTable 1 }
|
|
|
|
WtWebioEA12x12AlarmEntry ::= SEQUENCE {
|
|
wtWebioEA12x12AlarmInputTrigger OCTET STRING,
|
|
wtWebioEA12x12AlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA12x12AlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA12x12AlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA12x12AlarmInterval OCTET STRING,
|
|
wtWebioEA12x12AlarmEnable OCTET STRING,
|
|
wtWebioEA12x12AlarmMailAddr OCTET STRING,
|
|
wtWebioEA12x12AlarmMailSubject OCTET STRING,
|
|
wtWebioEA12x12AlarmMailText OCTET STRING,
|
|
wtWebioEA12x12AlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA12x12AlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA12x12AlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA12x12AlarmUdpPort INTEGER,
|
|
wtWebioEA12x12AlarmUdpText OCTET STRING,
|
|
wtWebioEA12x12AlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA12x12AlarmTcpPort INTEGER,
|
|
wtWebioEA12x12AlarmTcpText OCTET STRING,
|
|
wtWebioEA12x12AlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA12x12AlarmSyslogPort INTEGER,
|
|
wtWebioEA12x12AlarmSyslogText OCTET STRING,
|
|
wtWebioEA12x12AlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA12x12AlarmFtpFileName OCTET STRING,
|
|
wtWebioEA12x12AlarmFtpText OCTET STRING,
|
|
wtWebioEA12x12AlarmFtpOption OCTET STRING,
|
|
wtWebioEA12x12AlarmTimerCron OCTET STRING,
|
|
|
|
wtWebioEA12x12AlarmMailReleaseSubject OCTET STRING,
|
|
wtWebioEA12x12AlarmMailReleaseText OCTET STRING,
|
|
wtWebioEA12x12AlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebioEA12x12AlarmUdpReleaseText OCTET STRING,
|
|
wtWebioEA12x12AlarmTcpReleaseText OCTET STRING,
|
|
wtWebioEA12x12AlarmSyslogReleaseText OCTET STRING,
|
|
wtWebioEA12x12AlarmFtpReleaseText OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA12x12AlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3, Bit 0-3: Mask for digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Mask for digital inputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7, Bit 0-3: Level of digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 8, Bit 0-7: Level of digital inputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unsused
|
|
OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11
|
|
Bit 12-15 : unused
|
|
OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7"
|
|
|
|
::= { wtWebioEA12x12AlarmEntry 1 }
|
|
|
|
wtWebioEA12x12AlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3, Bit 0-3: Mask for digital outputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7, Bit 0-3: Level of digital outputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 8, Bit 0-7: Level of digital outputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11
|
|
Bit 12-15 : unused
|
|
OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7"
|
|
|
|
::= { wtWebioEA12x12AlarmEntry 2 }
|
|
|
|
wtWebioEA12x12AlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebioEA12x12AlarmEntry 3 }
|
|
|
|
wtWebioEA12x12AlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA12x12AlarmInputTrigger are not considered."
|
|
::= { wtWebioEA12x12AlarmEntry 4 }
|
|
|
|
wtWebioEA12x12AlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA12x12AlarmEntry 5 }
|
|
|
|
wtWebioEA12x12AlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA12x12AlarmEntry 6 }
|
|
|
|
wtWebioEA12x12AlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA12x12AlarmEntry 7 }
|
|
|
|
wtWebioEA12x12AlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA12x12AlarmEntry 8 }
|
|
|
|
wtWebioEA12x12AlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA12x12AlarmEntry 9 }
|
|
|
|
wtWebioEA12x12AlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA12x12AlarmEntry 10 }
|
|
|
|
wtWebioEA12x12AlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA12x12AlarmEntry 11 }
|
|
|
|
wtWebioEA12x12AlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA12x12AlarmEntry 12 }
|
|
|
|
wtWebioEA12x12AlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA12x12AlarmEntry 13 }
|
|
|
|
wtWebioEA12x12AlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA12x12AlarmEntry 14 }
|
|
|
|
wtWebioEA12x12AlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA12x12AlarmEntry 15 }
|
|
|
|
wtWebioEA12x12AlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA12x12AlarmEntry 16 }
|
|
|
|
wtWebioEA12x12AlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA12x12AlarmEntry 17 }
|
|
|
|
wtWebioEA12x12AlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA12x12AlarmEntry 18 }
|
|
|
|
wtWebioEA12x12AlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA12x12AlarmEntry 19 }
|
|
|
|
wtWebioEA12x12AlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA12x12AlarmEntry 20 }
|
|
|
|
wtWebioEA12x12AlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA12x12AlarmEntry 21 }
|
|
|
|
wtWebioEA12x12AlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA12x12AlarmEntry 22 }
|
|
|
|
wtWebioEA12x12AlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA12x12AlarmEntry 23 }
|
|
|
|
wtWebioEA12x12AlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA12x12AlarmEntry 24 }
|
|
|
|
wtWebioEA12x12AlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA12x12AlarmEntry 25 }
|
|
|
|
|
|
wtWebioEA12x12AlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA12x12AlarmEntry 26 }
|
|
|
|
wtWebioEA12x12AlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA12x12AlarmEntry 27 }
|
|
|
|
wtWebioEA12x12AlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA12x12AlarmEntry 28 }
|
|
|
|
wtWebioEA12x12AlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA12x12AlarmEntry 29 }
|
|
|
|
wtWebioEA12x12AlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA12x12AlarmEntry 30 }
|
|
|
|
wtWebioEA12x12AlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA12x12AlarmEntry 31 }
|
|
|
|
wtWebioEA12x12AlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA12x12AlarmEntry 32 }
|
|
|
|
-- wtWebioEA12x12LoadControl
|
|
----------------------------
|
|
|
|
wtWebioEA12x12LoadControlView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of automatic load control can be read. All output were tested in
|
|
pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3:
|
|
Bit 4-7: unused
|
|
Bit 0-3: outputs 8-11
|
|
Octet 4:
|
|
Bit 0-7: outputs 0-7."
|
|
::= { wtWebioEA12x12Alarm 4 }
|
|
|
|
wtWebioEA12x12LCShutDownView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of the automatic load control shut down can be read. All outputs remain switched of,
|
|
until a zero is written into this variable. But previously all loads should be inspected.
|
|
High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason.
|
|
If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair.
|
|
All controlled output could be identified reading the variable wtWebioEA12x12LoadControlEnable.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3:
|
|
Bit 4-7: unused
|
|
Bit 0-3: outputs 8-11
|
|
Octet 4:
|
|
Bit 0-7: outputs 0-7."
|
|
::= { wtWebioEA12x12Alarm 5 }
|
|
|
|
-- wtWebioEA12x12Ports Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA12x12InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA12x12Ports 1 }
|
|
|
|
wtWebioEA12x12InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA12x12InputNo }
|
|
::= { wtWebioEA12x12InputPortTable 1 }
|
|
|
|
WtWebioEA12x12InputPortEntry ::= SEQUENCE {
|
|
wtWebioEA12x12PortInputName OCTET STRING,
|
|
wtWebioEA12x12PortInputText OCTET STRING,
|
|
wtWebioEA12x12PortInputMode OCTET STRING,
|
|
wtWebioEA12x12PortInputFilter INTEGER,
|
|
wtWebioEA12x12PortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebioEA12x12PortInputBicountInactivTimeout INTEGER
|
|
}
|
|
|
|
wtWebioEA12x12PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA12x12InputPortEntry 1 }
|
|
|
|
wtWebioEA12x12PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA12x12InputPortEntry 2 }
|
|
|
|
wtWebioEA12x12PortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-3:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 3-7: unused
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable
|
|
|
|
Selection for inputs 4-11:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Counter clear on read
|
|
Bit 0 : Change detection enable (default)"
|
|
::= { wtWebioEA12x12InputPortEntry 3 }
|
|
|
|
wtWebioEA12x12PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA12x12InputPortEntry 4 }
|
|
|
|
wtWebioEA12x12PortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x12InputPortEntry 5 }
|
|
|
|
wtWebioEA12x12PortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebioEA12x12InputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA12x12OutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x12OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA12x12Ports 2 }
|
|
|
|
wtWebioEA12x12OutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x12OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA12x12OutputNo }
|
|
::= { wtWebioEA12x12OutputPortTable 1 }
|
|
|
|
WtWebioEA12x12OutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA12x12PortOutputName OCTET STRING,
|
|
wtWebioEA12x12PortOutputText OCTET STRING,
|
|
wtWebioEA12x12PortOutputGroupMode OCTET STRING,
|
|
wtWebioEA12x12PortOutputSafetyState OCTET STRING,
|
|
wtWebioEA12x12PortLogicInputMask OCTET STRING,
|
|
wtWebioEA12x12PortLogicInputInverter OCTET STRING,
|
|
wtWebioEA12x12PortLogicFunction OCTET STRING,
|
|
wtWebioEA12x12PortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA12x12PortPulseDuration INTEGER,
|
|
wtWebioEA12x12PortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA12x12PortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA12x12OutputPortEntry 1 }
|
|
|
|
wtWebioEA12x12PortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA12x12OutputPortEntry 2 }
|
|
|
|
wtWebioEA12x12PortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one output bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for outputs 0-3:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default)
|
|
Bit 1 : outputs 0+1, 2+3 connected
|
|
Bit 2 : outputs 0+1+2+3 connected
|
|
Bit 3-7 : unused
|
|
Selection for outputs 4-7:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default)
|
|
Bit 1 : outputs 4+5, 6+7 connected
|
|
Bit 2 : outputs 4+5+6+7 connected
|
|
Bit 3-7 : unused
|
|
Selection for outputs 8-11:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default)
|
|
Bit 1 : outputs 8+9, 10+11 connected
|
|
Bit 2 : outputs 8+9+10+11 connected
|
|
Bit 3-7 : unused"
|
|
::= { wtWebioEA12x12OutputPortEntry 3 }
|
|
|
|
wtWebioEA12x12PortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 Bit 4-7: unused
|
|
Bit 0-3: Mask for digital output 8-11
|
|
OCTET 4, Bit 0-7: Mask for digital output 0-7
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 Bit 4-7: unused
|
|
Bit 0-3: Level of digital output 8-11
|
|
OCTET 8 Bit 0-7 : Level of digital output 0-7"
|
|
::= { wtWebioEA12x12OutputPortEntry 4 }
|
|
|
|
wtWebioEA12x12PortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA12x12PortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA12x12PortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA12x12PortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA12x12PortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : inputs 8-11
|
|
Bit 4-7 : unused
|
|
OCTET 4:
|
|
Bit 0-7 : inputs 0-7"
|
|
::= { wtWebioEA12x12OutputPortEntry 5 }
|
|
|
|
wtWebioEA12x12PortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : inputs 8-11
|
|
Bit 4-7 : unused
|
|
OCTET 4:
|
|
Bit 0-7 : inputs 0-7"
|
|
::= { wtWebioEA12x12OutputPortEntry 6 }
|
|
|
|
wtWebioEA12x12PortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x12OutputPortEntry 7 }
|
|
|
|
wtWebioEA12x12PortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA12x12OutputPortEntry 8 }
|
|
|
|
wtWebioEA12x12PortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA12x12OutputPortEntry 9 }
|
|
|
|
wtWebioEA12x12PortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA12x12PortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x12OutputPortEntry 10 }
|
|
|
|
-- wtWebioEA12x12Manufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x12MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA12x12Manufact 1 }
|
|
|
|
wtWebioEA12x12MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA12x12Manufact 2 }
|
|
|
|
wtWebioEA12x12MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA12x12Manufact 3 }
|
|
|
|
wtWebioEA12x12MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA12x12Manufact 4 }
|
|
|
|
wtWebioEA12x12MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA12x12Manufact 5 }
|
|
|
|
-- wtWebioEA12x12Diag Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x12DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA12x12Diag 1 }
|
|
|
|
wtWebioEA12x12DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA12x12Diag 2 }
|
|
|
|
wtWebioEA12x12DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA12x12DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA12x12DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA12x12DiagErrorMessage."
|
|
::= { wtWebioEA12x12Diag 3 }
|
|
|
|
wtWebioEA12x12DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA12x12DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA12x12Diag 4 }
|
|
|
|
wtWebioEA12x12DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA12x12Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA12x12Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebioEA12x12Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebioEA12x12Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebioEA12x12Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebioEA12x12Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebioEA12x12Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebioEA12x12Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebioEA12x12Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebioEA12x12Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebioEA12x12Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebioEA12x12Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebioEA12x12Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebioEA12x12Alert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA12x12Alert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA12x12Alert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA12x12Alert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA12x12Alert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA12x12Alert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA12x12Alert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA12x12Alert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA12x12Alert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA12x12Alert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA12x12Alert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA12x12Alert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES { wtWebioEA12x12AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA12x12AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x12
|
|
VARIABLES {
|
|
wtWebioEA12x12DiagErrorIndex,
|
|
wtWebioEA12x12DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebioEA24oemInOut Group
|
|
------------------------
|
|
|
|
wtWebioEA24oemInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent inputs."
|
|
::= { wtWebioEA24oemInOut 1 }
|
|
|
|
wtWebioEA24oemOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent outputs."
|
|
::= { wtWebioEA24oemInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA24oemInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA24oemInOut 3 }
|
|
|
|
wtWebioEA24oemInputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the inputs."
|
|
INDEX { wtWebioEA24oemInputNo }
|
|
::= { wtWebioEA24oemInputTable 1 }
|
|
|
|
WtWebioEA24oemInputEntry ::= SEQUENCE {
|
|
wtWebioEA24oemInputNo INTEGER,
|
|
wtWebioEA24oemInputCounter INTEGER,
|
|
wtWebioEA24oemInputCounterClear INTEGER,
|
|
wtWebioEA24oemInputState INTEGER
|
|
}
|
|
|
|
wtWebioEA24oemInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA24oemInputEntry 1 }
|
|
|
|
wtWebioEA24oemInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA24oemInputEntry 2 }
|
|
|
|
wtWebioEA24oemInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter. After reading this counter will be cleared."
|
|
::= { wtWebioEA24oemInputEntry 3 }
|
|
|
|
wtWebioEA24oemInputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA24oemInputEntry 4 }
|
|
|
|
wtWebioEA24oemInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: Bit 0-7 : inputs 16 - 23
|
|
OCTET 3: Bit 0-7 : inputs 8 - 15
|
|
OCTET 4: Bit 0-7 : inputs 0 - 7"
|
|
::= { wtWebioEA24oemInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA24oemOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA24oemInOut 5 }
|
|
|
|
wtWebioEA24oemOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the outputs."
|
|
INDEX { wtWebioEA24oemOutputNo }
|
|
::= { wtWebioEA24oemOutputTable 1 }
|
|
|
|
WtWebioEA24oemOutputEntry ::= SEQUENCE {
|
|
wtWebioEA24oemOutputNo INTEGER,
|
|
wtWebioEA24oemOutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA24oemOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..24)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the outputs."
|
|
::= { wtWebioEA24oemOutputEntry 1 }
|
|
|
|
wtWebioEA24oemOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA24oemOutputEntry 2 }
|
|
|
|
wtWebioEA24oemOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: Bit 0-7: Digital outputs 16-23
|
|
OCTET 3, Bit 0-7: Digital outputs 8-15
|
|
OCTET 4, Bit 0-7: Digital outputs 0-7"
|
|
::= { wtWebioEA24oemInOut 6 }
|
|
|
|
wtWebioEA24oemSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1: unused
|
|
OCTET 2: Bit 0-7: Mask for digital outputs 16-23
|
|
OCTET 3, Bit 0-7: Mask for digital outputs 8-15
|
|
OCTET 4, Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5: unused
|
|
OCTET 6: Bit 0-7: Level of digital outputs 16-23
|
|
OCTET 7, Bit 0-7: Level of digital outputs 8-15
|
|
OCTET 8, Bit 0-7: Level of digital outputs 0-7"
|
|
::= { wtWebioEA24oemInOut 7 }
|
|
|
|
-- wtWebioEA24oemSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA24oemSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA24oemSessCntrl 1 }
|
|
|
|
wtWebioEA24oemSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA24oemSessCntrl 2 }
|
|
|
|
wtWebioEA24oemSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA24oemSessCntrl 3 }
|
|
|
|
wtWebioEA24oemSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA24oemSessCntrl 4 }
|
|
|
|
wtWebioEA24oemSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA24oemSessCntrl 5 }
|
|
|
|
-- wtWebioEA24oemText Group
|
|
------------------------
|
|
|
|
wtWebioEA24oemDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA24oemText 1 }
|
|
|
|
wtWebioEA24oemDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA24oemText 2 }
|
|
|
|
wtWebioEA24oemDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA24oemText 3 }
|
|
|
|
wtWebioEA24oemDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA24oemText 4 }
|
|
|
|
-- wtWebioEA24oemTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA24oemTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA24oemTimeZone 1 }
|
|
|
|
wtWebioEA24oemTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA24oemTimeZone 2 }
|
|
|
|
wtWebioEA24oemTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA24oemTimeZone 3 }
|
|
|
|
wtWebioEA24oemStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA24oemTimeZone 4 }
|
|
|
|
wtWebioEA24oemStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA24oemTimeZone 5 }
|
|
|
|
wtWebioEA24oemStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA24oemTimeZone 6 }
|
|
|
|
wtWebioEA24oemStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA24oemStartMonth-January(1),
|
|
wtWebioEA24oemStartMonth-February(2),
|
|
wtWebioEA24oemStartMonth-March(3),
|
|
wtWebioEA24oemStartMonth-April(4),
|
|
wtWebioEA24oemStartMonth-May(5),
|
|
wtWebioEA24oemStartMonth-June(6),
|
|
wtWebioEA24oemStartMonth-July(7),
|
|
wtWebioEA24oemStartMonth-August(8),
|
|
wtWebioEA24oemStartMonth-September(9),
|
|
wtWebioEA24oemStartMonth-October(10),
|
|
wtWebioEA24oemStartMonth-November(11),
|
|
wtWebioEA24oemStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA24oemTimeZone 7 }
|
|
|
|
wtWebioEA24oemStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA24oemStartMode-first(1),
|
|
wtWebioEA24oemStartMode-second(2),
|
|
wtWebioEA24oemStartMode-third(3),
|
|
wtWebioEA24oemStartMode-fourth(4),
|
|
wtWebioEA24oemStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA24oemTimeZone 8 }
|
|
|
|
wtWebioEA24oemStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA24oemStartWday-Sunday(1),
|
|
wtWebioEA24oemStartWday-Monday(2),
|
|
wtWebioEA24oemStartWday-Tuesday(3),
|
|
wtWebioEA24oemStartWday-Thursday(4),
|
|
wtWebioEA24oemStartWday-Wednesday(5),
|
|
wtWebioEA24oemStartWday-Friday(6),
|
|
wtWebioEA24oemStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA24oemTimeZone 9 }
|
|
|
|
wtWebioEA24oemStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA24oemTimeZone 10 }
|
|
|
|
wtWebioEA24oemStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA24oemTimeZone 11 }
|
|
|
|
wtWebioEA24oemStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA24oemStopMonth-January(1),
|
|
wtWebioEA24oemStopMonth-February(2),
|
|
wtWebioEA24oemStopMonth-March(3),
|
|
wtWebioEA24oemStopMonth-April(4),
|
|
wtWebioEA24oemStopMonth-May(5),
|
|
wtWebioEA24oemStopMonth-June(6),
|
|
wtWebioEA24oemStopMonth-July(7),
|
|
wtWebioEA24oemStopMonth-August(8),
|
|
wtWebioEA24oemStopMonth-September(9),
|
|
wtWebioEA24oemStopMonth-October(10),
|
|
wtWebioEA24oemStopMonth-November(11),
|
|
wtWebioEA24oemStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA24oemTimeZone 12 }
|
|
|
|
wtWebioEA24oemStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA24oemStopMode-first(1),
|
|
wtWebioEA24oemStopMode-second(2),
|
|
wtWebioEA24oemStopMode-third(3),
|
|
wtWebioEA24oemStopMode-fourth(4),
|
|
wtWebioEA24oemStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA24oemTimeZone 13 }
|
|
|
|
wtWebioEA24oemStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA24oemStopWday-Sunday(1),
|
|
wtWebioEA24oemStopWday-Monday(2),
|
|
wtWebioEA24oemStopWday-Tuesday(3),
|
|
wtWebioEA24oemStopWday-Thursday(4),
|
|
wtWebioEA24oemStopWday-Wednesday(5),
|
|
wtWebioEA24oemStopWday-Friday(6),
|
|
wtWebioEA24oemStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA24oemTimeZone 14 }
|
|
|
|
wtWebioEA24oemStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA24oemTimeZone 15 }
|
|
|
|
wtWebioEA24oemStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA24oemTimeZone 16 }
|
|
|
|
-- wtWebioEA24oemTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA24oemTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA24oemTimeServer 1 }
|
|
|
|
wtWebioEA24oemTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA24oemTimeServer 2 }
|
|
|
|
wtWebioEA24oemTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA24oemTimeServer 3 }
|
|
|
|
wtWebioEA24oemTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA24oemTimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA24oemDeviceClock Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA24oemDeviceClock 1 }
|
|
|
|
wtWebioEA24oemClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA24oemDeviceClock 2 }
|
|
|
|
wtWebioEA24oemClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA24oemDeviceClock 3 }
|
|
|
|
wtWebioEA24oemClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA24oemClockMonth-January(1),
|
|
wtWebioEA24oemClockMonth-February(2),
|
|
wtWebioEA24oemClockMonth-March(3),
|
|
wtWebioEA24oemClockMonth-April(4),
|
|
wtWebioEA24oemClockMonth-May(5),
|
|
wtWebioEA24oemClockMonth-June(6),
|
|
wtWebioEA24oemClockMonth-July(7),
|
|
wtWebioEA24oemClockMonth-August(8),
|
|
wtWebioEA24oemClockMonth-September(9),
|
|
wtWebioEA24oemClockMonth-October(10),
|
|
wtWebioEA24oemClockMonth-November(11),
|
|
wtWebioEA24oemClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA24oemDeviceClock 4 }
|
|
|
|
wtWebioEA24oemClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA24oemDeviceClock 5 }
|
|
|
|
-- wtWebioEA24oemNetwork Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA24oemNetwork 1 }
|
|
|
|
wtWebioEA24oemSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA24oemNetwork 2 }
|
|
|
|
wtWebioEA24oemGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA24oemNetwork 3 }
|
|
|
|
wtWebioEA24oemDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA24oemNetwork 4 }
|
|
|
|
wtWebioEA24oemDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA24oemNetwork 5 }
|
|
|
|
wtWebioEA24oemAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA24oemNetwork 6 }
|
|
|
|
-- wtWebioEA24oemHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA24oemHTTP 1 }
|
|
|
|
wtWebioEA24oemGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA24oemHTTP 2 }
|
|
|
|
wtWebioEA24oemHttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: Bit 0-7 : inputs 16 - 23
|
|
OCTET 3: Bit 0-7 : inputs 8 - 15
|
|
OCTET 4: Bit 0-7 : inputs 0 - 7"
|
|
::= { wtWebioEA24oemHTTP 3 }
|
|
|
|
wtWebioEA24oemHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA24oemHTTP 4 }
|
|
|
|
-- wtWebioEA24oemMail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA24oemMail 1 }
|
|
|
|
wtWebioEA24oemMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA24oemMail 2 }
|
|
|
|
wtWebioEA24oemMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA24oemMail 3 }
|
|
|
|
wtWebioEA24oemMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA24oemMail 4 }
|
|
|
|
wtWebioEA24oemMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA24oemMail 5 }
|
|
|
|
wtWebioEA24oemMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA24oemMail 6 }
|
|
|
|
wtWebioEA24oemMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA24oemMail 7 }
|
|
|
|
wtWebioEA24oemMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA24oemMail 8 }
|
|
|
|
|
|
-- wtWebioEA24oemSnmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA24oemSNMP 1 }
|
|
|
|
wtWebioEA24oemSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA24oemSNMP 2 }
|
|
|
|
wtWebioEA24oemSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA24oemSNMP 3 }
|
|
|
|
wtWebioEA24oemSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA24oemSNMP 4 }
|
|
|
|
wtWebioEA24oemSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA24oemSNMP 5 }
|
|
|
|
-- wtWebioEA24oemUdp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA24oemUDP 1 }
|
|
|
|
wtWebioEA24oemUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA24oemUDP 2 }
|
|
|
|
wtWebioEA24oemUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA24oemUDP 3 }
|
|
|
|
-- wtWebioEA24oemBinary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemBinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA24oemBinary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA24oemBinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA24oemBinary 2 }
|
|
|
|
wtWebioEA24oemBinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA24oemBinaryModeNo }
|
|
::= { wtWebioEA24oemBinaryIfTable 1 }
|
|
|
|
WtWebioEA24oemBinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA24oemBinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA24oemBinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA24oemBinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemBinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA24oemBinary 3 }
|
|
|
|
wtWebioEA24oemBinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA24oemBinaryModeNo }
|
|
::= { wtWebioEA24oemBinaryTable 1 }
|
|
|
|
WtWebioEA24oemBinaryEntry ::= SEQUENCE {
|
|
wtWebioEA24oemBinaryOperationMode OCTET STRING,
|
|
wtWebioEA24oemBinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA24oemBinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA24oemBinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA24oemBinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA24oemBinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA24oemBinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA24oemBinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA24oemBinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA24oemBinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA24oemBinaryTcpClientInterval INTEGER,
|
|
wtWebioEA24oemBinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA24oemBinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA24oemBinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA24oemBinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA24oemBinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA24oemBinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA24oemBinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA24oemBinaryConnectedPort INTEGER,
|
|
wtWebioEA24oemBinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA24oemBinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA24oemBinaryTcpClientServerHttpPort INTEGER
|
|
|
|
|
|
}
|
|
|
|
wtWebioEA24oemBinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA24oemBinaryEntry 1 }
|
|
|
|
wtWebioEA24oemBinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA24oemBinaryEntry 2 }
|
|
|
|
wtWebioEA24oemBinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: Bit 0-7 : inputs 16 - 23
|
|
OCTET 3: Bit 0-7 : inputs 8 - 15
|
|
OCTET 4: Bit 0-7 : inputs 0 - 7"
|
|
::= { wtWebioEA24oemBinaryEntry 3 }
|
|
|
|
wtWebioEA24oemBinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA24oemBinaryEntry 4 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA24oemBinaryEntry 5 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA24oemBinaryEntry 6 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA24oemBinaryEntry 7 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA24oemBinaryEntry 8 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA24oemBinaryEntry 9 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: Bit 0-7 : inputs 16 - 23
|
|
OCTET 3: Bit 0-7 : inputs 8 - 15
|
|
OCTET 4: Bit 0-7 : inputs 0 - 7"
|
|
::= { wtWebioEA24oemBinaryEntry 10 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA24oemBinaryEntry 11 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA24oemBinaryEntry 12 }
|
|
|
|
wtWebioEA24oemBinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA24oemBinaryEntry 13 }
|
|
|
|
wtWebioEA24oemBinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA24oemBinaryEntry 14 }
|
|
|
|
wtWebioEA24oemBinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA24oemBinaryEntry 15 }
|
|
|
|
wtWebioEA24oemBinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: Bit 0-7 : inputs 16 - 23
|
|
OCTET 3: Bit 0-7 : inputs 8 - 15
|
|
OCTET 4: Bit 0-7 : inputs 0 - 7"
|
|
::= { wtWebioEA24oemBinaryEntry 16 }
|
|
|
|
wtWebioEA24oemBinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA24oemBinaryEntry 17 }
|
|
|
|
wtWebioEA24oemBinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA24oemBinaryEntry 18 }
|
|
|
|
wtWebioEA24oemBinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA24oemBinaryEntry 19 }
|
|
|
|
wtWebioEA24oemBinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA24oemBinaryEntry 20 }
|
|
|
|
wtWebioEA24oemBinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA24oemBinaryEntry 21 }
|
|
|
|
wtWebioEA24oemBinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA24oemBinaryEntry 22 }
|
|
|
|
-- wtWebioEA24oemSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA24oemSyslog 1 }
|
|
|
|
wtWebioEA24oemSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA24oemSyslog 2 }
|
|
|
|
wtWebioEA24oemSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA24oemSyslog 3 }
|
|
|
|
wtWebioEA24oemSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA24oemSyslog 4 }
|
|
|
|
-- wtWebioEA24oemFTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA24oemFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA24oemFTP 1 }
|
|
|
|
wtWebioEA24oemFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA24oemFTP 2 }
|
|
|
|
wtWebioEA24oemFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA24oemFTP 3 }
|
|
|
|
wtWebioEA24oemFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA24oemFTP 4 }
|
|
|
|
wtWebioEA24oemFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA24oemFTP 5 }
|
|
|
|
wtWebioEA24oemFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA24oemFTP 6 }
|
|
|
|
wtWebioEA24oemFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA24oemFTP 7 }
|
|
|
|
-- wtWebioEA24oemOutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA24oemOutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA24oemOutputMode 1 }
|
|
|
|
wtWebioEA24oemOutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA24oemOutputNo }
|
|
::= { wtWebioEA24oemOutputModeTable 1 }
|
|
|
|
WtWebioEA24oemOutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA24oemOutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA24oemOutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA24oemOutputModeEntry 1 }
|
|
|
|
wtWebioEA24oemSafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA24oemOutputMode 2 }
|
|
|
|
wtWebioEA24oemLoadControlEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the function of automatic load control can be enabled. All output were tested in
|
|
pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Load Control enable"
|
|
::= { wtWebioEA24oemOutputMode 3 }
|
|
|
|
-- wtWebioEA24oemAlarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA24oemAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA24oemAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA24oemAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA24oemAlarm 2 }
|
|
|
|
wtWebioEA24oemAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA24oemAlarmNo }
|
|
::= { wtWebioEA24oemAlarmIfTable 1 }
|
|
|
|
WtWebioEA24oemAlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA24oemAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA24oemAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA24oemAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA24oemAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA24oemAlarm 3 }
|
|
|
|
wtWebioEA24oemAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA24oemAlarmNo }
|
|
::= { wtWebioEA24oemAlarmTable 1 }
|
|
|
|
WtWebioEA24oemAlarmEntry ::= SEQUENCE {
|
|
wtWebioEA24oemAlarmInputTrigger OCTET STRING,
|
|
wtWebioEA24oemAlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA24oemAlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA24oemAlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA24oemAlarmInterval OCTET STRING,
|
|
wtWebioEA24oemAlarmEnable OCTET STRING,
|
|
wtWebioEA24oemAlarmMailAddr OCTET STRING,
|
|
wtWebioEA24oemAlarmMailSubject OCTET STRING,
|
|
wtWebioEA24oemAlarmMailText OCTET STRING,
|
|
wtWebioEA24oemAlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA24oemAlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA24oemAlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA24oemAlarmUdpPort INTEGER,
|
|
wtWebioEA24oemAlarmUdpText OCTET STRING,
|
|
wtWebioEA24oemAlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA24oemAlarmTcpPort INTEGER,
|
|
wtWebioEA24oemAlarmTcpText OCTET STRING,
|
|
wtWebioEA24oemAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA24oemAlarmSyslogPort INTEGER,
|
|
wtWebioEA24oemAlarmSyslogText OCTET STRING,
|
|
wtWebioEA24oemAlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA24oemAlarmFtpFileName OCTET STRING,
|
|
wtWebioEA24oemAlarmFtpText OCTET STRING,
|
|
wtWebioEA24oemAlarmFtpOption OCTET STRING,
|
|
wtWebioEA24oemAlarmTimerCron OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA24oemAlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2: Bit 0-7: Mask for digital inputs 16-23
|
|
OCTET 3, Bit 0-7: Mask for digital inputs 8-15
|
|
OCTET 4, Bit 0-7: Mask for digital inputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6: Bit 0-7: Level of digital inputs 16-23
|
|
OCTET 7, Bit 0-7: Level of digital inputs 8-15
|
|
OCTET 8, Bit 0-7: Level of digital inputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10, Bit 0-7: ANY bits of digital inputs 16-23
|
|
OCTET 11, Bit 0-7: ANY bits of digital inputs 8-15
|
|
OCTET 12, Bit 0-7: ANY bits of digital inputs 0-7"
|
|
|
|
::= { wtWebioEA24oemAlarmEntry 1 }
|
|
|
|
wtWebioEA24oemAlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2: Bit 0-7: Mask for digital outputs 16-23
|
|
OCTET 3, Bit 0-7: Mask for digital outputs 8-15
|
|
OCTET 4, Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6: Bit 0-7: Level of digital outputs 16-23
|
|
OCTET 7, Bit 0-7: Level of digital outputs 8-15
|
|
OCTET 8, Bit 0-7: Level of digital outputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10, Bit 0-7: ANY bits of digital outputs 16-23
|
|
OCTET 11, Bit 0-7: ANY bits of digital outputs 8-15
|
|
OCTET 12, Bit 0-7: ANY bits of digital outputs 0-7"
|
|
|
|
::= { wtWebioEA24oemAlarmEntry 2 }
|
|
|
|
wtWebioEA24oemAlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebioEA24oemAlarmEntry 3 }
|
|
|
|
wtWebioEA24oemAlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA24oemAlarmInputTrigger are not considered."
|
|
::= { wtWebioEA24oemAlarmEntry 4 }
|
|
|
|
wtWebioEA24oemAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA24oemAlarmEntry 5 }
|
|
|
|
wtWebioEA24oemAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4-7: unused"
|
|
::= { wtWebioEA24oemAlarmEntry 6 }
|
|
|
|
wtWebioEA24oemAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA24oemAlarmEntry 7 }
|
|
|
|
wtWebioEA24oemAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA24oemAlarmEntry 8 }
|
|
|
|
wtWebioEA24oemAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA24oemAlarmEntry 9 }
|
|
|
|
wtWebioEA24oemAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA24oemAlarmEntry 10 }
|
|
|
|
wtWebioEA24oemAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA24oemAlarmEntry 11 }
|
|
|
|
wtWebioEA24oemAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA24oemAlarmEntry 12 }
|
|
|
|
wtWebioEA24oemAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA24oemAlarmEntry 13 }
|
|
|
|
wtWebioEA24oemAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA24oemAlarmEntry 14 }
|
|
|
|
wtWebioEA24oemAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA24oemAlarmEntry 15 }
|
|
|
|
wtWebioEA24oemAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA24oemAlarmEntry 16 }
|
|
|
|
wtWebioEA24oemAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA24oemAlarmEntry 17 }
|
|
|
|
wtWebioEA24oemAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA24oemAlarmEntry 18 }
|
|
|
|
wtWebioEA24oemAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA24oemAlarmEntry 19 }
|
|
|
|
wtWebioEA24oemAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA24oemAlarmEntry 20 }
|
|
|
|
wtWebioEA24oemAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA24oemAlarmEntry 21 }
|
|
|
|
wtWebioEA24oemAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA24oemAlarmEntry 22 }
|
|
|
|
wtWebioEA24oemAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA24oemAlarmEntry 23 }
|
|
|
|
wtWebioEA24oemAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA24oemAlarmEntry 24 }
|
|
|
|
wtWebioEA24oemAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA24oemAlarmEntry 25 }
|
|
|
|
-- wtWebioEA24oemLoadControl
|
|
----------------------------
|
|
|
|
wtWebioEA24oemLoadControlView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of automatic load control can be read. All output were tested in
|
|
pairs (0-1, 2-3, 4-5, 6-7, 8-9, 10-11). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
OCTET 2: Bit 0-7 : outputs 16 - 23
|
|
OCTET 3: Bit 0-7 : outputs 8 - 15
|
|
OCTET 4: Bit 0-7 : outputs 0 - 7"
|
|
::= { wtWebioEA24oemAlarm 4 }
|
|
|
|
wtWebioEA24oemLCShutDownView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of the automatic load control shut down can be read. All outputs remain switched of,
|
|
until a zero is written into this variable. But previously all loads should be inspected.
|
|
High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason.
|
|
If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair.
|
|
All controlled output could be identified reading the variable wtWebioEA24oemLoadControlEnable.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
Octet 1: unused
|
|
OCTET 2: Bit 0-7 : outputs 16 - 23
|
|
OCTET 3: Bit 0-7 : outputs 8 - 15
|
|
OCTET 4: Bit 0-7 : outputs 0 - 7"
|
|
::= { wtWebioEA24oemAlarm 5 }
|
|
|
|
|
|
-- wtWebioEA24oemPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA24oemInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA24oemPorts 1 }
|
|
|
|
wtWebioEA24oemInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA24oemInputNo }
|
|
::= { wtWebioEA24oemInputPortTable 1 }
|
|
|
|
WtWebioEA24oemInputPortEntry ::= SEQUENCE {
|
|
wtWebioEA24oemPortInputName OCTET STRING,
|
|
wtWebioEA24oemPortInputText OCTET STRING,
|
|
wtWebioEA24oemPortInputMode OCTET STRING,
|
|
wtWebioEA24oemPortInputFilter INTEGER
|
|
}
|
|
|
|
wtWebioEA24oemPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA24oemInputPortEntry 1 }
|
|
|
|
wtWebioEA24oemPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA24oemInputPortEntry 2 }
|
|
|
|
wtWebioEA24oemPortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-3:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable
|
|
|
|
Selection for inputs 4-11:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Counter clear on read
|
|
Bit 0 : Change detection enable (default)"
|
|
::= { wtWebioEA24oemInputPortEntry 3 }
|
|
|
|
wtWebioEA24oemPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA24oemInputPortEntry 4 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA24oemOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA24oemOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA24oemPorts 2 }
|
|
|
|
wtWebioEA24oemOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA24oemOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA24oemOutputNo }
|
|
::= { wtWebioEA24oemOutputPortTable 1 }
|
|
|
|
WtWebioEA24oemOutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA24oemPortOutputName OCTET STRING,
|
|
wtWebioEA24oemPortOutputText OCTET STRING,
|
|
wtWebioEA24oemPortOutputGroupMode OCTET STRING,
|
|
wtWebioEA24oemPortOutputSafetyState OCTET STRING,
|
|
wtWebioEA24oemPortLogicInputMask OCTET STRING,
|
|
wtWebioEA24oemPortLogicInputInverter OCTET STRING,
|
|
wtWebioEA24oemPortLogicFunction OCTET STRING,
|
|
wtWebioEA24oemPortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA24oemPortPulseDuration INTEGER,
|
|
wtWebioEA24oemPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA24oemPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA24oemOutputPortEntry 1 }
|
|
|
|
wtWebioEA24oemPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA24oemOutputPortEntry 2 }
|
|
|
|
wtWebioEA24oemPortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one output bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for outputs 0-3:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default)
|
|
Bit 1 : outputs 0+1, 2+3 connected
|
|
Bit 2 : outputs 0+1+2+3 connected
|
|
Bit 3-7 : unused
|
|
Selection for outputs 4-7:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 4, 5, 6, 7 disconnected (default)
|
|
Bit 1 : outputs 4+5, 6+7 connected
|
|
Bit 2 : outputs 4+5+6+7 connected
|
|
Bit 3-7 : unused
|
|
Selection for outputs 8-11:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 8, 9, 10, 11 disconnected (default)
|
|
Bit 1 : outputs 8+9, 10+11 connected
|
|
Bit 2 : outputs 8+9+10+11 connected
|
|
Bit 3-7 : unused
|
|
|
|
Selection for outputs 12-15:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0 : outputs 12,13,14,15 disconnected (default)
|
|
Bit 1 : outputs 12+13,14+15 connected
|
|
Bit 2 : outputs 12+13+14+15 connected
|
|
Bit 3-7 : unused
|
|
|
|
Selection for outputs 16-19:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0 : outputs 16,17,18,19 disconnected (default)
|
|
Bit 1 : outputs 16+17,18+19 connected
|
|
Bit 2 : outputs 16+17+18+19 connected
|
|
Bit 3-7 : unused
|
|
|
|
Selection for outputs 20-23:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0 : outputs 20,21,22,23 disconnected (default)
|
|
Bit 1 : outputs 20+21,22+23 connected
|
|
Bit 2 : outputs 20+21+22+23 connected
|
|
Bit 3-7 : unused"
|
|
|
|
::= { wtWebioEA24oemOutputPortEntry 3 }
|
|
|
|
wtWebioEA24oemPortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebioEA24oemOutputPortEntry 4 }
|
|
|
|
wtWebioEA24oemPortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA24oemPortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA24oemPortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA24oemPortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA24oemPortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: Bit 0-7 : inputs 16 - 23
|
|
OCTET 3: Bit 0-7 : inputs 8 - 15
|
|
OCTET 4: Bit 0-7 : inputs 0 - 7"
|
|
::= { wtWebioEA24oemOutputPortEntry 5 }
|
|
|
|
wtWebioEA24oemPortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: Bit 0-7 : inputs 16 - 23
|
|
OCTET 3: Bit 0-7 : inputs 8 - 15
|
|
OCTET 4: Bit 0-7 : inputs 0 - 7"
|
|
::= { wtWebioEA24oemOutputPortEntry 6 }
|
|
|
|
wtWebioEA24oemPortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA24oemOutputPortEntry 7 }
|
|
|
|
wtWebioEA24oemPortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA24oemOutputPortEntry 8 }
|
|
|
|
wtWebioEA24oemPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA24oemOutputPortEntry 9 }
|
|
|
|
wtWebioEA24oemPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA24oemPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : ungenutzt"
|
|
::= { wtWebioEA24oemOutputPortEntry 10 }
|
|
|
|
|
|
-- wtWebioEA24oemManufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA24oemMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA24oemManufact 1 }
|
|
|
|
wtWebioEA24oemMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA24oemManufact 2 }
|
|
|
|
wtWebioEA24oemMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA24oemManufact 3 }
|
|
|
|
wtWebioEA24oemMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA24oemManufact 4 }
|
|
|
|
wtWebioEA24oemMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA24oemManufact 5 }
|
|
|
|
-- wtWebioEA24oemDiag Group
|
|
----------------------------
|
|
|
|
wtWebioEA24oemDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA24oemDiag 1 }
|
|
|
|
wtWebioEA24oemDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA24oemDiag 2 }
|
|
|
|
wtWebioEA24oemDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA24oemDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA24oemDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA24oemDiagErrorMessage."
|
|
::= { wtWebioEA24oemDiag 3 }
|
|
|
|
wtWebioEA24oemDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA24oemDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA24oemDiag 4 }
|
|
|
|
wtWebioEA24oemDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA24oemDiag 5 }
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA24oemAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 53
|
|
|
|
wtWebioEA24oemAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 54
|
|
|
|
wtWebioEA24oemAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 55
|
|
|
|
wtWebioEA24oemAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 56
|
|
|
|
wtWebioEA24oemAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 57
|
|
|
|
wtWebioEA24oemAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 58
|
|
|
|
wtWebioEA24oemAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 59
|
|
|
|
wtWebioEA24oemAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 60
|
|
|
|
wtWebioEA24oemAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 61
|
|
|
|
wtWebioEA24oemAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 62
|
|
|
|
wtWebioEA24oemAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 63
|
|
|
|
wtWebioEA24oemAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 64
|
|
|
|
wtWebioEA24oemAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 13 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 13"
|
|
--#SUMMARY "Alarm 13: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 65
|
|
|
|
wtWebioEA24oemAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 14 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 14"
|
|
--#SUMMARY "Alarm 14: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 66
|
|
|
|
wtWebioEA24oemAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 15 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 15"
|
|
--#SUMMARY "Alarm 15: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 67
|
|
|
|
wtWebioEA24oemAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 16 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 16"
|
|
--#SUMMARY "Alarm 16: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 68
|
|
|
|
wtWebioEA24oemAlert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA24oemAlert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA24oemAlert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA24oemAlert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA24oemAlert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA24oemAlert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA24oemAlert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA24oemAlert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA24oemAlert25 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA24oemAlert26 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA24oemAlert27 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA24oemAlert28 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA24oemAlert29 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 13 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 13"
|
|
--#SUMMARY "Release Alarm 13: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 83
|
|
|
|
wtWebioEA24oemAlert30 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 14 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 14"
|
|
--#SUMMARY "Release Alarm 14: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 84
|
|
|
|
wtWebioEA24oemAlert31 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 15 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 15"
|
|
--#SUMMARY "Release Alarm 15: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 85
|
|
|
|
wtWebioEA24oemAlert32 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES { wtWebioEA24oemAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 16 was released,
|
|
SNMP trap enable is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 16"
|
|
--#SUMMARY "Release Alarm 16: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 86
|
|
|
|
wtWebioEA24oemAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA24oem
|
|
VARIABLES {
|
|
wtWebioEA24oemDiagErrorIndex,
|
|
wtWebioEA24oemDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diag/error message was generated,
|
|
the SNMP-Trap-Enable bit is set and SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebio577xxEA12x6RelInOut Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA12x6RelInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebio577xxEA12x6RelInOut 1 }
|
|
|
|
wtWebio577xxEA12x6RelOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebio577xxEA12x6RelInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebio577xxEA12x6RelInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebio577xxEA12x6RelInOut 3 }
|
|
|
|
wtWebio577xxEA12x6RelInputEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebio577xxEA12x6RelInputNo }
|
|
::= { wtWebio577xxEA12x6RelInputTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelInputEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelInputNo INTEGER,
|
|
wtWebio577xxEA12x6RelInputCounter INTEGER,
|
|
wtWebio577xxEA12x6RelInputCounterClear INTEGER,
|
|
wtWebio577xxEA12x6RelInputState INTEGER
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebio577xxEA12x6RelInputEntry 1 }
|
|
|
|
wtWebio577xxEA12x6RelInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebio577xxEA12x6RelInputEntry 2 }
|
|
|
|
wtWebio577xxEA12x6RelInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebio577xxEA12x6RelInputEntry 3 }
|
|
|
|
wtWebio577xxEA12x6RelInputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebio577xxEA12x6RelInputEntry 4 }
|
|
|
|
wtWebio577xxEA12x6RelInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-6: Digital outputs 0-6"
|
|
::= { wtWebio577xxEA12x6RelInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebio577xxEA12x6RelOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebio577xxEA12x6RelInOut 5 }
|
|
|
|
wtWebio577xxEA12x6RelOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebio577xxEA12x6RelOutputNo }
|
|
::= { wtWebio577xxEA12x6RelOutputTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelOutputEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelOutputNo INTEGER,
|
|
wtWebio577xxEA12x6RelOutputState INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebio577xxEA12x6RelOutputEntry 1 }
|
|
|
|
wtWebio577xxEA12x6RelOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebio577xxEA12x6RelOutputEntry 2 }
|
|
|
|
|
|
wtWebio577xxEA12x6RelOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-6: Digital outputs 0-6"
|
|
|
|
::= { wtWebio577xxEA12x6RelInOut 6 }
|
|
|
|
wtWebio577xxEA12x6RelSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4 : Bit 0-6: Mask for digital outputs 0-6
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8 : Bit 0-6: Mask for digital outputs 0-6"
|
|
::= { wtWebio577xxEA12x6RelInOut 7 }
|
|
|
|
-- wtWebio577xxEA12x6RelSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebio577xxEA12x6RelSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebio577xxEA12x6RelSessCntrl 1 }
|
|
|
|
wtWebio577xxEA12x6RelSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebio577xxEA12x6RelSessCntrl 2 }
|
|
|
|
wtWebio577xxEA12x6RelSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebio577xxEA12x6RelSessCntrl 3 }
|
|
|
|
wtWebio577xxEA12x6RelSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebio577xxEA12x6RelSessCntrl 4 }
|
|
|
|
wtWebio577xxEA12x6RelSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebio577xxEA12x6RelSessCntrl 5 }
|
|
|
|
-- wtWebio577xxEA12x6RelText Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA12x6RelDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA12x6RelText 1 }
|
|
|
|
wtWebio577xxEA12x6RelDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA12x6RelText 2 }
|
|
|
|
wtWebio577xxEA12x6RelDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA12x6RelText 3 }
|
|
|
|
wtWebio577xxEA12x6RelDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebio577xxEA12x6RelText 4 }
|
|
|
|
-- wtWebio577xxEA12x6RelTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x6RelTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 1 }
|
|
|
|
wtWebio577xxEA12x6RelTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 2 }
|
|
|
|
wtWebio577xxEA12x6RelTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebio577xxEA12x6RelTimeZone 3 }
|
|
|
|
wtWebio577xxEA12x6RelStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 4 }
|
|
|
|
wtWebio577xxEA12x6RelStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 5 }
|
|
|
|
wtWebio577xxEA12x6RelStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebio577xxEA12x6RelTimeZone 6 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x6RelStartMonth-January(1),
|
|
wtWebio577xxEA12x6RelStartMonth-February(2),
|
|
wtWebio577xxEA12x6RelStartMonth-March(3),
|
|
wtWebio577xxEA12x6RelStartMonth-April(4),
|
|
wtWebio577xxEA12x6RelStartMonth-May(5),
|
|
wtWebio577xxEA12x6RelStartMonth-June(6),
|
|
wtWebio577xxEA12x6RelStartMonth-July(7),
|
|
wtWebio577xxEA12x6RelStartMonth-August(8),
|
|
wtWebio577xxEA12x6RelStartMonth-September(9),
|
|
wtWebio577xxEA12x6RelStartMonth-October(10),
|
|
wtWebio577xxEA12x6RelStartMonth-November(11),
|
|
wtWebio577xxEA12x6RelStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 7 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x6RelStartMode-first(1),
|
|
wtWebio577xxEA12x6RelStartMode-second(2),
|
|
wtWebio577xxEA12x6RelStartMode-third(3),
|
|
wtWebio577xxEA12x6RelStartMode-fourth(4),
|
|
wtWebio577xxEA12x6RelStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 8 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x6RelStartWday-Sunday(1),
|
|
wtWebio577xxEA12x6RelStartWday-Monday(2),
|
|
wtWebio577xxEA12x6RelStartWday-Tuesday(3),
|
|
wtWebio577xxEA12x6RelStartWday-Thursday(4),
|
|
wtWebio577xxEA12x6RelStartWday-Wednesday(5),
|
|
wtWebio577xxEA12x6RelStartWday-Friday(6),
|
|
wtWebio577xxEA12x6RelStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebio577xxEA12x6RelTimeZone 9 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 10 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 11 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x6RelStopMonth-January(1),
|
|
wtWebio577xxEA12x6RelStopMonth-February(2),
|
|
wtWebio577xxEA12x6RelStopMonth-March(3),
|
|
wtWebio577xxEA12x6RelStopMonth-April(4),
|
|
wtWebio577xxEA12x6RelStopMonth-May(5),
|
|
wtWebio577xxEA12x6RelStopMonth-June(6),
|
|
wtWebio577xxEA12x6RelStopMonth-July(7),
|
|
wtWebio577xxEA12x6RelStopMonth-August(8),
|
|
wtWebio577xxEA12x6RelStopMonth-September(9),
|
|
wtWebio577xxEA12x6RelStopMonth-October(10),
|
|
wtWebio577xxEA12x6RelStopMonth-November(11),
|
|
wtWebio577xxEA12x6RelStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 12 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x6RelStopMode-first(1),
|
|
wtWebio577xxEA12x6RelStopMode-second(2),
|
|
wtWebio577xxEA12x6RelStopMode-third(3),
|
|
wtWebio577xxEA12x6RelStopMode-fourth(4),
|
|
wtWebio577xxEA12x6RelStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 13 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x6RelStopWday-Sunday(1),
|
|
wtWebio577xxEA12x6RelStopWday-Monday(2),
|
|
wtWebio577xxEA12x6RelStopWday-Tuesday(3),
|
|
wtWebio577xxEA12x6RelStopWday-Thursday(4),
|
|
wtWebio577xxEA12x6RelStopWday-Wednesday(5),
|
|
wtWebio577xxEA12x6RelStopWday-Friday(6),
|
|
wtWebio577xxEA12x6RelStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 14 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 15 }
|
|
|
|
wtWebio577xxEA12x6RelStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebio577xxEA12x6RelTimeZone 16 }
|
|
|
|
-- wtWebio577xxEA12x6RelTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x6RelTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebio577xxEA12x6RelTimeServer 1 }
|
|
|
|
wtWebio577xxEA12x6RelTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebio577xxEA12x6RelTimeServer 2 }
|
|
|
|
wtWebio577xxEA12x6RelTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebio577xxEA12x6RelTimeServer 3 }
|
|
|
|
wtWebio577xxEA12x6RelTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebio577xxEA12x6RelTimeServer 4 }
|
|
|
|
|
|
-- wtWebio577xxEA12x6RelDeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x6RelClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x6RelDeviceClock 1 }
|
|
|
|
wtWebio577xxEA12x6RelClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x6RelDeviceClock 2 }
|
|
|
|
wtWebio577xxEA12x6RelClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x6RelDeviceClock 3 }
|
|
|
|
wtWebio577xxEA12x6RelClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebio577xxEA12x6RelClockMonth-January(1),
|
|
wtWebio577xxEA12x6RelClockMonth-February(2),
|
|
wtWebio577xxEA12x6RelClockMonth-March(3),
|
|
wtWebio577xxEA12x6RelClockMonth-April(4),
|
|
wtWebio577xxEA12x6RelClockMonth-May(5),
|
|
wtWebio577xxEA12x6RelClockMonth-June(6),
|
|
wtWebio577xxEA12x6RelClockMonth-July(7),
|
|
wtWebio577xxEA12x6RelClockMonth-August(8),
|
|
wtWebio577xxEA12x6RelClockMonth-September(9),
|
|
wtWebio577xxEA12x6RelClockMonth-October(10),
|
|
wtWebio577xxEA12x6RelClockMonth-November(11),
|
|
wtWebio577xxEA12x6RelClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x6RelDeviceClock 4 }
|
|
|
|
wtWebio577xxEA12x6RelClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebio577xxEA12x6RelDeviceClock 5 }
|
|
|
|
-- wtWebio577xxEA12x6RelNetwork Group
|
|
------------------------
|
|
|
|
wtWebio577xxEA12x6RelIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebio577xxEA12x6RelNetwork 1 }
|
|
|
|
wtWebio577xxEA12x6RelSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebio577xxEA12x6RelNetwork 2 }
|
|
|
|
wtWebio577xxEA12x6RelGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebio577xxEA12x6RelNetwork 3 }
|
|
|
|
wtWebio577xxEA12x6RelDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebio577xxEA12x6RelNetwork 4 }
|
|
|
|
wtWebio577xxEA12x6RelDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebio577xxEA12x6RelNetwork 5 }
|
|
|
|
wtWebio577xxEA12x6RelAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebio577xxEA12x6RelNetwork 6 }
|
|
|
|
-- wtWebio577xxEA12x6RelHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebio577xxEA12x6RelHTTP 1 }
|
|
|
|
wtWebio577xxEA12x6RelGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebio577xxEA12x6RelHTTP 2 }
|
|
|
|
wtWebio577xxEA12x6RelHttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA12x6RelHTTP 3 }
|
|
|
|
wtWebio577xxEA12x6RelHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebio577xxEA12x6RelHTTP 4 }
|
|
|
|
|
|
-- wtWebio577xxEA12x6RelMail Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebio577xxEA12x6RelMail 1 }
|
|
|
|
wtWebio577xxEA12x6RelMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebio577xxEA12x6RelMail 2 }
|
|
|
|
wtWebio577xxEA12x6RelMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebio577xxEA12x6RelMail 3 }
|
|
|
|
wtWebio577xxEA12x6RelMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebio577xxEA12x6RelMail 4 }
|
|
|
|
wtWebio577xxEA12x6RelMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebio577xxEA12x6RelMail 5 }
|
|
|
|
wtWebio577xxEA12x6RelMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebio577xxEA12x6RelMail 6 }
|
|
|
|
wtWebio577xxEA12x6RelMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebio577xxEA12x6RelMail 7 }
|
|
|
|
wtWebio577xxEA12x6RelMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebio577xxEA12x6RelMail 8 }
|
|
|
|
|
|
-- wtWebio577xxEA12x6RelSnmp Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebio577xxEA12x6RelSNMP 1 }
|
|
|
|
wtWebio577xxEA12x6RelSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebio577xxEA12x6RelSNMP 2 }
|
|
|
|
wtWebio577xxEA12x6RelSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebio577xxEA12x6RelSNMP 3 }
|
|
|
|
wtWebio577xxEA12x6RelSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebio577xxEA12x6RelSNMP 4 }
|
|
|
|
wtWebio577xxEA12x6RelSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebio577xxEA12x6RelSNMP 5 }
|
|
|
|
wtWebio577xxEA12x6RelSnmpSystemTrapManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the system trap."
|
|
::= { wtWebio577xxEA12x6RelSNMP 6 }
|
|
|
|
-- wtWebio577xxEA12x6RelUDP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebio577xxEA12x6RelUDP 1 }
|
|
|
|
wtWebio577xxEA12x6RelUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebio577xxEA12x6RelUDP 2 }
|
|
|
|
wtWebio577xxEA12x6RelUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebio577xxEA12x6RelUDP 3 }
|
|
|
|
-- wtWebio577xxEA12x6RelBinary Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelBinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebio577xxEA12x6RelBinary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebio577xxEA12x6RelBinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebio577xxEA12x6RelBinary 2 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebio577xxEA12x6RelBinaryModeNo }
|
|
::= { wtWebio577xxEA12x6RelBinaryIfTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelBinaryIfEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelBinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelBinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebio577xxEA12x6RelBinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelBinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebio577xxEA12x6RelBinary 3 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebio577xxEA12x6RelBinaryModeNo }
|
|
::= { wtWebio577xxEA12x6RelBinaryTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelBinaryEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelBinaryOperationMode OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryTcpServerLocalPort INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientLocalPort INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerPort INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientInactivity INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientInterval INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerLocalPort INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerRemotePort INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerInterval INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebio577xxEA12x6RelBinaryConnectedPort INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryConnectedIpAddr IpAddress,
|
|
wtWebio577xxEA12x6RelBinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerHttpPort INTEGER,
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerUserName OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelBinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 1 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 2 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 3 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 4 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 5 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 6 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 7 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 8 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 9 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 10 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 11 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 12 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 13 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 14 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 15 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-6: Digital inputs 0-6"
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 16 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 17 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 18 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 19 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 20 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 21 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 22 }
|
|
|
|
wtWebio577xxEA12x6RelBinaryTcpClientServerUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User Name to login at the remote server, if authentication needed."
|
|
::= { wtWebio577xxEA12x6RelBinaryEntry 23 }
|
|
|
|
|
|
-- wtWebio577xxEA12x6RelSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebio577xxEA12x6RelSyslog 1 }
|
|
|
|
wtWebio577xxEA12x6RelSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebio577xxEA12x6RelSyslog 2 }
|
|
|
|
wtWebio577xxEA12x6RelSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebio577xxEA12x6RelSyslog 3 }
|
|
|
|
wtWebio577xxEA12x6RelSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebio577xxEA12x6RelSyslog 4 }
|
|
|
|
-- wtWebio577xxEA12x6RelFTP Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebio577xxEA12x6RelFTP 1 }
|
|
|
|
wtWebio577xxEA12x6RelFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebio577xxEA12x6RelFTP 2 }
|
|
|
|
wtWebio577xxEA12x6RelFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebio577xxEA12x6RelFTP 3 }
|
|
|
|
wtWebio577xxEA12x6RelFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebio577xxEA12x6RelFTP 4 }
|
|
|
|
wtWebio577xxEA12x6RelFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebio577xxEA12x6RelFTP 5 }
|
|
|
|
wtWebio577xxEA12x6RelFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebio577xxEA12x6RelFTP 6 }
|
|
|
|
wtWebio577xxEA12x6RelFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebio577xxEA12x6RelFTP 7 }
|
|
|
|
-- wtWebio577xxEA12x6RelMQTT Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelMQTTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 7 enables MQTT:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0-6: unused
|
|
Bit 7 : MQTT enable"
|
|
::= { wtWebio577xxEA12x6RelMQTT 1 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTBrockerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP-address of the MQTT-Server."
|
|
::= { wtWebio577xxEA12x6RelMQTT 2 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login user name."
|
|
::= { wtWebio577xxEA12x6RelMQTT 3 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login password."
|
|
::= { wtWebio577xxEA12x6RelMQTT 4 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local port number."
|
|
::= { wtWebio577xxEA12x6RelMQTT 5 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTBrokerServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Server port number."
|
|
::= { wtWebio577xxEA12x6RelMQTT 6 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ping intervall, if no data has to be send: time in seconds."
|
|
::= { wtWebio577xxEA12x6RelMQTT 7 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTLastWillEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will enable"
|
|
::= { wtWebio577xxEA12x6RelMQTT 8 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTLastWillTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Topic."
|
|
::= { wtWebio577xxEA12x6RelMQTT 9 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTLastWillMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will message."
|
|
::= { wtWebio577xxEA12x6RelMQTT 10 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTLastWillQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish QoS:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebio577xxEA12x6RelMQTT 11 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTLastWillRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish Retain properties:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA12x6RelMQTT 12 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTLastWillConnectEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill Connect message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will connect message enable"
|
|
::= { wtWebio577xxEA12x6RelMQTT 13 }
|
|
|
|
wtWebio577xxEA12x6RelMQTTLastWillConnectMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Connect message will be send with the QoS and Retain settings
|
|
of the LastWill message."
|
|
::= { wtWebio577xxEA12x6RelMQTT 14 }
|
|
|
|
|
|
-- wtWebio577xxEA1x1REST Group
|
|
--------------------------------
|
|
|
|
wtWebio577xxEA12x6RelRESTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates REST:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : REST enable"
|
|
::= { wtWebio577xxEA12x6RelREST 1 }
|
|
|
|
wtWebio577xxEA12x6RelRESTDigestAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates Digest-Authentification:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Digest Auth enable"
|
|
::= { wtWebio577xxEA12x6RelREST 2 }
|
|
|
|
-- wtWebio577xxEA12x6RelOutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebio577xxEA12x6RelOutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebio577xxEA12x6RelOutputMode 1 }
|
|
|
|
wtWebio577xxEA12x6RelOutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebio577xxEA12x6RelOutputNo }
|
|
::= { wtWebio577xxEA12x6RelOutputModeTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelOutputModeEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelOutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelOutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebio577xxEA12x6RelOutputModeEntry 1 }
|
|
|
|
wtWebio577xxEA12x6RelSafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebio577xxEA12x6RelOutputMode 2 }
|
|
|
|
|
|
-- wtWebio577xxEA12x6RelAlarm Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x6RelAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebio577xxEA12x6RelAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebio577xxEA12x6RelAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebio577xxEA12x6RelAlarm 2 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebio577xxEA12x6RelAlarmNo }
|
|
::= { wtWebio577xxEA12x6RelAlarmIfTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelAlarmIfEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebio577xxEA12x6RelAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebio577xxEA12x6RelAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebio577xxEA12x6RelAlarm 3 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebio577xxEA12x6RelAlarmNo }
|
|
::= { wtWebio577xxEA12x6RelAlarmTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelAlarmEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelAlarmInputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmOutputTrigger OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSystemTrigger OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmMaxCounterValue OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmInterval OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmEnable OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmMailAddr OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmMailSubject OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmMailText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSnmpManagerIP OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSnmpTrapText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmUdpIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmUdpPort INTEGER,
|
|
wtWebio577xxEA12x6RelAlarmUdpText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmTcpIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmTcpPort INTEGER,
|
|
wtWebio577xxEA12x6RelAlarmTcpText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSyslogPort INTEGER,
|
|
wtWebio577xxEA12x6RelAlarmSyslogText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmFtpDataPort OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmFtpFileName OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmFtpText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmFtpOption OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmTimerCron OCTET STRING,
|
|
|
|
wtWebio577xxEA12x6RelAlarmMailReleaseSubject OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmMailReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmUdpReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmTcpReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSyslogReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmFtpReleaseText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmGlobalEnable OCTET STRING,
|
|
|
|
wtWebio577xxEA12x6RelAlarmCombinationLogic OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmTrgMqttTopic OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmTrgMqttTopicText OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmHttpReqAuthEnable OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmHttpReqAuthUser OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmHttpReqAuthPassword OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmHttpReqSetUrl OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmHttpReqClearUrl OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmHttpReqServerPort INTEGER,
|
|
wtWebio577xxEA12x6RelAlarmMqttTopicPath OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmMqttTopicSetTopic OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmMqttTopicClear OCTET STRING,
|
|
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsOwn OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsServerIp OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsServerPort INTEGER,
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsServerPassword OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsServerOutputs OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsDest OCTET STRING,
|
|
|
|
wtWebio577xxEA12x6RelAlarmSnmpManagerPort INTEGER,
|
|
wtWebio577xxEA12x6RelAlarmMqttQoS OCTET STRING,
|
|
wtWebio577xxEA12x6RelAlarmMqttRetain OCTET STRING
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelAlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3, Bit 0-3: Mask for digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Mask for digital inputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7, Bit 0-3: Level of digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 8, Bit 0-7: Level of digital inputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unsused
|
|
OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11
|
|
Bit 12-15 : unused
|
|
OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 1 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4 : Bit 0-6: Mask for digital outputs 0-6
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8 : Bit 0-6: Level of digital outputs 0-6
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 11: unused
|
|
OCTET 12: Bit 0-6 : ANY bits of digital inputs 0-6"
|
|
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 2 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 3 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebio577xxEA12x6RelAlarmInputTrigger are not considered."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 4 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 5 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Bit 0: UDP enable
|
|
Bit1-7: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: TCP Client enable
|
|
Bit 3: Syslog Messages enable
|
|
Bit 4: FTP enable
|
|
Bit 5: HTTP Request enable
|
|
Bit 6 MQTT Publish enable
|
|
Bit 7: Set Outputs"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 6 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 7 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 8 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 9 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 10 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 11 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 12 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 13 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 14 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 15 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 16 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 17 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 18 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 19 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 20 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 21 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 22 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 23 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 24 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 25 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 26 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 27 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 28 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 29 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 30 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 31 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 32 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Alarm enable"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 34 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmCombinationLogic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded logic, all Input/Output-trigger will be combined:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : OR
|
|
Bit 0 : AND"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 58 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmTrgMqttTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT subscribe topic."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 59 }
|
|
|
|
|
|
wtWebio577xxEA12x6RelAlarmTrgMqttTopicText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Receiving this text from the MQTT Broker, Alarm will be triggered."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 60 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmHttpReqAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : HHTP Request Authentication enable"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 61 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmHttpReqAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: User"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 62 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmHttpReqAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Password"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 63 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmHttpReqSetUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Set URL"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 64 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmHttpReqClearUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Clear URL"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 65 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmHttpReqServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Server Port"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 66 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMqttTopicPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic path"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 67 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMqttTopicSetTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic SET message"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 68 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMqttTopicClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic CLEAR message"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 69 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsOwn OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4 : Bit 0-6: Mask for digital outputs 0-6
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8 : Bit 0-6: Level of digital outputs 0-6
|
|
|
|
OCTETS 9-12 are unused."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 70 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsServerIp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server IP Address"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 71 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server Port"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 72 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Outputs: Server Pasword"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 73 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsServerOutputs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : Bit 0-3: Level of digital outputs 8-11
|
|
OCTET 4 : Bit 0-7: Mask for digital outputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : Bit 0-3: Level of digital outputs 8-11
|
|
OCTET 8 : Bit 0-7: Level of digital outputs 0-7
|
|
|
|
OCTETS 9-12 are unused."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 74 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSetOutputsDest OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Bit 0 = LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : set outputs of remote server.
|
|
Bit 0 : set outputs of this WEB-IO"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 75 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmSnmpManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 76 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMqttQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 77 }
|
|
|
|
wtWebio577xxEA12x6RelAlarmMqttRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebio577xxEA12x6RelAlarmEntry 78 }
|
|
|
|
-- wtWebio577xxEA12x6RelPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebio577xxEA12x6RelInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebio577xxEA12x6RelPorts 1 }
|
|
|
|
wtWebio577xxEA12x6RelInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebio577xxEA12x6RelInputNo }
|
|
::= { wtWebio577xxEA12x6RelInputPortTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelInputPortEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelPortInputName OCTET STRING,
|
|
wtWebio577xxEA12x6RelPortInputText OCTET STRING,
|
|
wtWebio577xxEA12x6RelPortInputMode OCTET STRING,
|
|
wtWebio577xxEA12x6RelPortInputFilter INTEGER,
|
|
wtWebio577xxEA12x6RelPortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebio577xxEA12x6RelPortInputBicountInactivTimeout INTEGER
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebio577xxEA12x6RelInputPortEntry 1 }
|
|
|
|
wtWebio577xxEA12x6RelPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebio577xxEA12x6RelInputPortEntry 2 }
|
|
|
|
wtWebio577xxEA12x6RelPortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable"
|
|
::= { wtWebio577xxEA12x6RelInputPortEntry 3 }
|
|
|
|
wtWebio577xxEA12x6RelPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebio577xxEA12x6RelInputPortEntry 4 }
|
|
|
|
wtWebio577xxEA12x6RelPortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA12x6RelInputPortEntry 5 }
|
|
|
|
wtWebio577xxEA12x6RelPortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebio577xxEA12x6RelInputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebio577xxEA12x6RelOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebio577xxEA12x6RelOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebio577xxEA12x6RelPorts 2 }
|
|
|
|
wtWebio577xxEA12x6RelOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebio577xxEA12x6RelOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebio577xxEA12x6RelOutputNo }
|
|
::= { wtWebio577xxEA12x6RelOutputPortTable 1 }
|
|
|
|
WtWebio577xxEA12x6RelOutputPortEntry ::= SEQUENCE {
|
|
wtWebio577xxEA12x6RelPortOutputName OCTET STRING,
|
|
wtWebio577xxEA12x6RelPortOutputText OCTET STRING,
|
|
wtWebio577xxEA12x6RelPortOutputGroupMode OCTET STRING,
|
|
wtWebio577xxEA12x6RelPortOutputSafetyState OCTET STRING,
|
|
wtWebio577xxEA12x6RelPortPulseDuration INTEGER,
|
|
wtWebio577xxEA12x6RelPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebio577xxEA12x6RelPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebio577xxEA12x6RelOutputPortEntry 1 }
|
|
|
|
wtWebio577xxEA12x6RelPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebio577xxEA12x6RelOutputPortEntry 2 }
|
|
|
|
wtWebio577xxEA12x6RelPortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"No function within this device."
|
|
::= { wtWebio577xxEA12x6RelOutputPortEntry 3 }
|
|
|
|
wtWebio577xxEA12x6RelPortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4 Bit 0-6: Mask for digital output 0-6
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : Unused
|
|
OCTET 8 Bit 0-6: Level of digital output 0-6"
|
|
::= { wtWebio577xxEA12x6RelOutputPortEntry 4 }
|
|
|
|
wtWebio577xxEA12x6RelPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebio577xxEA12x6RelOutputPortEntry 9 }
|
|
|
|
wtWebio577xxEA12x6RelPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebio577xxEA12x6RelPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebio577xxEA12x6RelOutputPortEntry 10 }
|
|
|
|
-- wtWebio577xxEA12x6RelManufact Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x6RelMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebio577xxEA12x6RelManufact 1 }
|
|
|
|
wtWebio577xxEA12x6RelMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebio577xxEA12x6RelManufact 2 }
|
|
|
|
wtWebio577xxEA12x6RelMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebio577xxEA12x6RelManufact 3 }
|
|
|
|
wtWebio577xxEA12x6RelMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebio577xxEA12x6RelManufact 4 }
|
|
|
|
wtWebio577xxEA12x6RelMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebio577xxEA12x6RelManufact 5 }
|
|
|
|
-- wtWebio577xxEA12x6RelDiag Group
|
|
----------------------------
|
|
|
|
wtWebio577xxEA12x6RelDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebio577xxEA12x6RelDiag 1 }
|
|
|
|
wtWebio577xxEA12x6RelDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebio577xxEA12x6RelDiag 2 }
|
|
|
|
wtWebio577xxEA12x6RelDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebio577xxEA12x6RelDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebio577xxEA12x6RelDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebio577xxEA12x6RelDiagErrorMessage."
|
|
::= { wtWebio577xxEA12x6RelDiag 3 }
|
|
|
|
wtWebio577xxEA12x6RelDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebio577xxEA12x6RelDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebio577xxEA12x6RelDiag 4 }
|
|
|
|
wtWebio577xxEA12x6RelDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebio577xxEA12x6RelDiag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebio577xxEA12x6RelAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebio577xxEA12x6RelAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebio577xxEA12x6RelAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebio577xxEA12x6RelAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebio577xxEA12x6RelAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebio577xxEA12x6RelAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebio577xxEA12x6RelAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebio577xxEA12x6RelAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebio577xxEA12x6RelAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebio577xxEA12x6RelAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebio577xxEA12x6RelAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebio577xxEA12x6RelAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebio577xxEA12x6RelAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebio577xxEA12x6RelAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebio577xxEA12x6RelAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebio577xxEA12x6RelAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebio577xxEA12x6RelAlert17 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebio577xxEA12x6RelAlert18 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebio577xxEA12x6RelAlert19 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebio577xxEA12x6RelAlert20 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebio577xxEA12x6RelAlert21 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebio577xxEA12x6RelAlert22 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebio577xxEA12x6RelAlert23 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebio577xxEA12x6RelAlert24 TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES { wtWebio577xxEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebio577xxEA12x6RelAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebio577xxEA12x6Rel
|
|
VARIABLES {
|
|
wtWebio577xxEA12x6RelDiagErrorIndex,
|
|
wtWebio577xxEA12x6RelDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebioEA12x6RelInOut Group
|
|
------------------------
|
|
|
|
wtWebioEA12x6RelInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebioEA12x6RelInOut 1 }
|
|
|
|
wtWebioEA12x6RelOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent outputs."
|
|
::= { wtWebioEA12x6RelInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA12x6RelInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA12x6RelInOut 3 }
|
|
|
|
wtWebioEA12x6RelInputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebioEA12x6RelInputNo }
|
|
::= { wtWebioEA12x6RelInputTable 1 }
|
|
|
|
WtWebioEA12x6RelInputEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelInputNo INTEGER,
|
|
wtWebioEA12x6RelInputCounter INTEGER,
|
|
wtWebioEA12x6RelInputCounterClear INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA12x6RelInputEntry 1 }
|
|
|
|
wtWebioEA12x6RelInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA12x6RelInputEntry 2 }
|
|
|
|
wtWebioEA12x6RelInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebioEA12x6RelInputEntry 3 }
|
|
|
|
wtWebioEA12x6RelInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA12x6RelOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA12x6RelInOut 5 }
|
|
|
|
wtWebioEA12x6RelOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebioEA12x6RelOutputNo }
|
|
::= { wtWebioEA12x6RelOutputTable 1 }
|
|
|
|
WtWebioEA12x6RelOutputEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelOutputNo INTEGER,
|
|
wtWebioEA12x6RelOutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebioEA12x6RelOutputEntry 1 }
|
|
|
|
wtWebioEA12x6RelOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting and reading of the states of the outputs, 0-OFF, 1-ON."
|
|
::= { wtWebioEA12x6RelOutputEntry 2 }
|
|
|
|
wtWebioEA12x6RelOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-5: Digital outputs 0-5"
|
|
::= { wtWebioEA12x6RelInOut 6 }
|
|
|
|
wtWebioEA12x6RelSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4 : Bit 0-5: Mask for digital outputs 0-5
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8 : Bit 0-5: Level of digital outputs 0-5"
|
|
::= { wtWebioEA12x6RelInOut 7 }
|
|
|
|
-- wtWebioEA12x6RelSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA12x6RelSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA12x6RelSessCntrl 1 }
|
|
|
|
wtWebioEA12x6RelSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA12x6RelSessCntrl 2 }
|
|
|
|
wtWebioEA12x6RelSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA12x6RelSessCntrl 3 }
|
|
|
|
wtWebioEA12x6RelSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA12x6RelSessCntrl 4 }
|
|
|
|
wtWebioEA12x6RelSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA12x6RelSessCntrl 5 }
|
|
|
|
-- wtWebioEA12x6RelText Group
|
|
------------------------
|
|
|
|
wtWebioEA12x6RelDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA12x6RelText 1 }
|
|
|
|
wtWebioEA12x6RelDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA12x6RelText 2 }
|
|
|
|
wtWebioEA12x6RelDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA12x6RelText 3 }
|
|
|
|
wtWebioEA12x6RelDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA12x6RelText 4 }
|
|
|
|
-- wtWebioEA12x6RelTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA12x6RelTimeZone 1 }
|
|
|
|
wtWebioEA12x6RelTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA12x6RelTimeZone 2 }
|
|
|
|
wtWebioEA12x6RelTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA12x6RelTimeZone 3 }
|
|
|
|
wtWebioEA12x6RelStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA12x6RelTimeZone 4 }
|
|
|
|
wtWebioEA12x6RelStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA12x6RelTimeZone 5 }
|
|
|
|
wtWebioEA12x6RelStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA12x6RelTimeZone 6 }
|
|
|
|
wtWebioEA12x6RelStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelStartMonth-January(1),
|
|
wtWebioEA12x6RelStartMonth-February(2),
|
|
wtWebioEA12x6RelStartMonth-March(3),
|
|
wtWebioEA12x6RelStartMonth-April(4),
|
|
wtWebioEA12x6RelStartMonth-May(5),
|
|
wtWebioEA12x6RelStartMonth-June(6),
|
|
wtWebioEA12x6RelStartMonth-July(7),
|
|
wtWebioEA12x6RelStartMonth-August(8),
|
|
wtWebioEA12x6RelStartMonth-September(9),
|
|
wtWebioEA12x6RelStartMonth-October(10),
|
|
wtWebioEA12x6RelStartMonth-November(11),
|
|
wtWebioEA12x6RelStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA12x6RelTimeZone 7 }
|
|
|
|
wtWebioEA12x6RelStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelStartMode-first(1),
|
|
wtWebioEA12x6RelStartMode-second(2),
|
|
wtWebioEA12x6RelStartMode-third(3),
|
|
wtWebioEA12x6RelStartMode-fourth(4),
|
|
wtWebioEA12x6RelStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA12x6RelTimeZone 8 }
|
|
|
|
wtWebioEA12x6RelStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelStartWday-Sunday(1),
|
|
wtWebioEA12x6RelStartWday-Monday(2),
|
|
wtWebioEA12x6RelStartWday-Tuesday(3),
|
|
wtWebioEA12x6RelStartWday-Thursday(4),
|
|
wtWebioEA12x6RelStartWday-Wednesday(5),
|
|
wtWebioEA12x6RelStartWday-Friday(6),
|
|
wtWebioEA12x6RelStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA12x6RelTimeZone 9 }
|
|
|
|
wtWebioEA12x6RelStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x6RelTimeZone 10 }
|
|
|
|
wtWebioEA12x6RelStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x6RelTimeZone 11 }
|
|
|
|
wtWebioEA12x6RelStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelStopMonth-January(1),
|
|
wtWebioEA12x6RelStopMonth-February(2),
|
|
wtWebioEA12x6RelStopMonth-March(3),
|
|
wtWebioEA12x6RelStopMonth-April(4),
|
|
wtWebioEA12x6RelStopMonth-May(5),
|
|
wtWebioEA12x6RelStopMonth-June(6),
|
|
wtWebioEA12x6RelStopMonth-July(7),
|
|
wtWebioEA12x6RelStopMonth-August(8),
|
|
wtWebioEA12x6RelStopMonth-September(9),
|
|
wtWebioEA12x6RelStopMonth-October(10),
|
|
wtWebioEA12x6RelStopMonth-November(11),
|
|
wtWebioEA12x6RelStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x6RelTimeZone 12 }
|
|
|
|
wtWebioEA12x6RelStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelStopMode-first(1),
|
|
wtWebioEA12x6RelStopMode-second(2),
|
|
wtWebioEA12x6RelStopMode-third(3),
|
|
wtWebioEA12x6RelStopMode-fourth(4),
|
|
wtWebioEA12x6RelStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x6RelTimeZone 13 }
|
|
|
|
wtWebioEA12x6RelStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelStopWday-Sunday(1),
|
|
wtWebioEA12x6RelStopWday-Monday(2),
|
|
wtWebioEA12x6RelStopWday-Tuesday(3),
|
|
wtWebioEA12x6RelStopWday-Thursday(4),
|
|
wtWebioEA12x6RelStopWday-Wednesday(5),
|
|
wtWebioEA12x6RelStopWday-Friday(6),
|
|
wtWebioEA12x6RelStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x6RelTimeZone 14 }
|
|
|
|
wtWebioEA12x6RelStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x6RelTimeZone 15 }
|
|
|
|
wtWebioEA12x6RelStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x6RelTimeZone 16 }
|
|
|
|
-- wtWebioEA12x6RelTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA12x6RelTimeServer 1 }
|
|
|
|
wtWebioEA12x6RelTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA12x6RelTimeServer 2 }
|
|
|
|
wtWebioEA12x6RelTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA12x6RelTimeServer 3 }
|
|
|
|
wtWebioEA12x6RelTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA12x6RelTimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA12x6RelDeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelDeviceClock 1 }
|
|
|
|
wtWebioEA12x6RelClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelDeviceClock 2 }
|
|
|
|
wtWebioEA12x6RelClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelDeviceClock 3 }
|
|
|
|
wtWebioEA12x6RelClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelClockMonth-January(1),
|
|
wtWebioEA12x6RelClockMonth-February(2),
|
|
wtWebioEA12x6RelClockMonth-March(3),
|
|
wtWebioEA12x6RelClockMonth-April(4),
|
|
wtWebioEA12x6RelClockMonth-May(5),
|
|
wtWebioEA12x6RelClockMonth-June(6),
|
|
wtWebioEA12x6RelClockMonth-July(7),
|
|
wtWebioEA12x6RelClockMonth-August(8),
|
|
wtWebioEA12x6RelClockMonth-September(9),
|
|
wtWebioEA12x6RelClockMonth-October(10),
|
|
wtWebioEA12x6RelClockMonth-November(11),
|
|
wtWebioEA12x6RelClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelDeviceClock 4 }
|
|
|
|
wtWebioEA12x6RelClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelDeviceClock 5 }
|
|
|
|
-- wtWebioEA12x6RelNetwork Group
|
|
------------------------
|
|
|
|
wtWebioEA12x6RelIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA12x6RelNetwork 1 }
|
|
|
|
wtWebioEA12x6RelSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA12x6RelNetwork 2 }
|
|
|
|
wtWebioEA12x6RelGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA12x6RelNetwork 3 }
|
|
|
|
wtWebioEA12x6RelDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA12x6RelNetwork 4 }
|
|
|
|
wtWebioEA12x6RelDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA12x6RelNetwork 5 }
|
|
|
|
wtWebioEA12x6RelAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA12x6RelNetwork 6 }
|
|
|
|
-- wtWebioEA12x6RelHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA12x6RelHTTP 1 }
|
|
|
|
wtWebioEA12x6RelGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA12x6RelHTTP 2 }
|
|
|
|
wtWebioEA12x6RelHttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelHTTP 3 }
|
|
|
|
wtWebioEA12x6RelHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA12x6RelHTTP 4 }
|
|
|
|
|
|
-- wtWebioEA12x6RelMail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA12x6RelMail 1 }
|
|
|
|
wtWebioEA12x6RelMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA12x6RelMail 2 }
|
|
|
|
wtWebioEA12x6RelMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA12x6RelMail 3 }
|
|
|
|
wtWebioEA12x6RelMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA12x6RelMail 4 }
|
|
|
|
wtWebioEA12x6RelMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA12x6RelMail 5 }
|
|
|
|
wtWebioEA12x6RelMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA12x6RelMail 6 }
|
|
|
|
wtWebioEA12x6RelMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA12x6RelMail 7 }
|
|
|
|
wtWebioEA12x6RelMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA12x6RelMail 8 }
|
|
|
|
|
|
-- wtWebioEA12x6RelSnmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA12x6RelSNMP 1 }
|
|
|
|
wtWebioEA12x6RelSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA12x6RelSNMP 2 }
|
|
|
|
wtWebioEA12x6RelSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA12x6RelSNMP 3 }
|
|
|
|
wtWebioEA12x6RelSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA12x6RelSNMP 4 }
|
|
|
|
wtWebioEA12x6RelSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA12x6RelSNMP 5 }
|
|
|
|
-- wtWebioEA12x6RelUdp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA12x6RelUDP 1 }
|
|
|
|
wtWebioEA12x6RelUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA12x6RelUDP 2 }
|
|
|
|
wtWebioEA12x6RelUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA12x6RelUDP 3 }
|
|
|
|
-- wtWebioEA12x6RelBinary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelBinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA12x6RelBinary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA12x6RelBinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA12x6RelBinary 2 }
|
|
|
|
wtWebioEA12x6RelBinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA12x6RelBinaryModeNo }
|
|
::= { wtWebioEA12x6RelBinaryIfTable 1 }
|
|
|
|
WtWebioEA12x6RelBinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelBinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelBinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA12x6RelBinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelBinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA12x6RelBinary 3 }
|
|
|
|
wtWebioEA12x6RelBinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA12x6RelBinaryModeNo }
|
|
::= { wtWebioEA12x6RelBinaryTable 1 }
|
|
|
|
WtWebioEA12x6RelBinaryEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelBinaryOperationMode OCTET STRING,
|
|
wtWebioEA12x6RelBinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA12x6RelBinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelBinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA12x6RelBinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA12x6RelBinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA12x6RelBinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelBinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA12x6RelBinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA12x6RelBinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelBinaryTcpClientInterval INTEGER,
|
|
wtWebioEA12x6RelBinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA12x6RelBinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA12x6RelBinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA12x6RelBinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelBinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelBinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA12x6RelBinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA12x6RelBinaryConnectedPort INTEGER,
|
|
wtWebioEA12x6RelBinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA12x6RelBinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA12x6RelBinaryTcpClientServerHttpPort INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA12x6RelBinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA12x6RelBinaryEntry 1 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x6RelBinaryEntry 2 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelBinaryEntry 3 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x6RelBinaryEntry 4 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x6RelBinaryEntry 5 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA12x6RelBinaryEntry 6 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA12x6RelBinaryEntry 7 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA12x6RelBinaryEntry 8 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA12x6RelBinaryEntry 9 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelBinaryEntry 10 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA12x6RelBinaryEntry 11 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x6RelBinaryEntry 12 }
|
|
|
|
wtWebioEA12x6RelBinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x6RelBinaryEntry 13 }
|
|
|
|
wtWebioEA12x6RelBinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA12x6RelBinaryEntry 14 }
|
|
|
|
wtWebioEA12x6RelBinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA12x6RelBinaryEntry 15 }
|
|
|
|
wtWebioEA12x6RelBinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelBinaryEntry 16 }
|
|
|
|
wtWebioEA12x6RelBinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA12x6RelBinaryEntry 17 }
|
|
|
|
wtWebioEA12x6RelBinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x6RelBinaryEntry 18 }
|
|
|
|
wtWebioEA12x6RelBinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA12x6RelBinaryEntry 19 }
|
|
|
|
wtWebioEA12x6RelBinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA12x6RelBinaryEntry 20 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA12x6RelBinaryEntry 21 }
|
|
|
|
wtWebioEA12x6RelBinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA12x6RelBinaryEntry 22 }
|
|
|
|
-- wtWebioEA12x6RelSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA12x6RelSyslog 1 }
|
|
|
|
wtWebioEA12x6RelSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA12x6RelSyslog 2 }
|
|
|
|
wtWebioEA12x6RelSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA12x6RelSyslog 3 }
|
|
|
|
wtWebioEA12x6RelSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA12x6RelSyslog 4 }
|
|
|
|
-- wtWebioEA12x6RelFTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA12x6RelFTP 1 }
|
|
|
|
wtWebioEA12x6RelFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA12x6RelFTP 2 }
|
|
|
|
wtWebioEA12x6RelFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA12x6RelFTP 3 }
|
|
|
|
wtWebioEA12x6RelFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA12x6RelFTP 4 }
|
|
|
|
wtWebioEA12x6RelFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA12x6RelFTP 5 }
|
|
|
|
wtWebioEA12x6RelFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA12x6RelFTP 6 }
|
|
|
|
wtWebioEA12x6RelFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA12x6RelFTP 7 }
|
|
|
|
-- wtWebioEA12x6RelOutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA12x6RelOutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA12x6RelOutputMode 1 }
|
|
|
|
wtWebioEA12x6RelOutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA12x6RelOutputNo }
|
|
::= { wtWebioEA12x6RelOutputModeTable 1 }
|
|
|
|
WtWebioEA12x6RelOutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelOutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA12x6RelOutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA12x6RelOutputModeEntry 1 }
|
|
|
|
wtWebioEA12x6RelSafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA12x6RelOutputMode 2 }
|
|
|
|
|
|
-- wtWebioEA12x6RelAlarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA12x6RelAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA12x6RelAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA12x6RelAlarm 2 }
|
|
|
|
wtWebioEA12x6RelAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA12x6RelAlarmNo }
|
|
::= { wtWebioEA12x6RelAlarmIfTable 1 }
|
|
|
|
WtWebioEA12x6RelAlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA12x6RelAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA12x6RelAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA12x6RelAlarm 3 }
|
|
|
|
wtWebioEA12x6RelAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA12x6RelAlarmNo }
|
|
::= { wtWebioEA12x6RelAlarmTable 1 }
|
|
|
|
WtWebioEA12x6RelAlarmEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelAlarmInputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelAlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelAlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA12x6RelAlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA12x6RelAlarmInterval OCTET STRING,
|
|
wtWebioEA12x6RelAlarmEnable OCTET STRING,
|
|
wtWebioEA12x6RelAlarmMailAddr OCTET STRING,
|
|
wtWebioEA12x6RelAlarmMailSubject OCTET STRING,
|
|
wtWebioEA12x6RelAlarmMailText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA12x6RelAlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelAlarmUdpPort INTEGER,
|
|
wtWebioEA12x6RelAlarmUdpText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelAlarmTcpPort INTEGER,
|
|
wtWebioEA12x6RelAlarmTcpText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelAlarmSyslogPort INTEGER,
|
|
wtWebioEA12x6RelAlarmSyslogText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA12x6RelAlarmFtpFileName OCTET STRING,
|
|
wtWebioEA12x6RelAlarmFtpText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmFtpOption OCTET STRING,
|
|
wtWebioEA12x6RelAlarmTimerCron OCTET STRING,
|
|
|
|
wtWebioEA12x6RelAlarmMailReleaseSubject OCTET STRING,
|
|
wtWebioEA12x6RelAlarmMailReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmUdpReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmTcpReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmSyslogReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelAlarmFtpReleaseText OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA12x6RelAlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3, Bit 0-3: Mask for digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Mask for digital inputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7, Bit 0-3: Level of digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 8, Bit 0-7: Level of digital inputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11
|
|
Bit 12-15 : unused
|
|
OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7"
|
|
|
|
::= { wtWebioEA12x6RelAlarmEntry 1 }
|
|
|
|
wtWebioEA12x6RelAlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-5: Mask for digital outputs 0-5
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-5: Level of digital outputs 0-5
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12: Bit 0-5: ANY bits of digital outputs 0-5"
|
|
|
|
::= { wtWebioEA12x6RelAlarmEntry 2 }
|
|
|
|
wtWebioEA12x6RelAlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebioEA12x6RelAlarmEntry 3 }
|
|
|
|
wtWebioEA12x6RelAlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA12x6RelAlarmInputTrigger are not considered."
|
|
::= { wtWebioEA12x6RelAlarmEntry 4 }
|
|
|
|
wtWebioEA12x6RelAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA12x6RelAlarmEntry 5 }
|
|
|
|
wtWebioEA12x6RelAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA12x6RelAlarmEntry 6 }
|
|
|
|
wtWebioEA12x6RelAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA12x6RelAlarmEntry 7 }
|
|
|
|
wtWebioEA12x6RelAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA12x6RelAlarmEntry 8 }
|
|
|
|
wtWebioEA12x6RelAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA12x6RelAlarmEntry 9 }
|
|
|
|
wtWebioEA12x6RelAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA12x6RelAlarmEntry 10 }
|
|
|
|
wtWebioEA12x6RelAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA12x6RelAlarmEntry 11 }
|
|
|
|
wtWebioEA12x6RelAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA12x6RelAlarmEntry 12 }
|
|
|
|
wtWebioEA12x6RelAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA12x6RelAlarmEntry 13 }
|
|
|
|
wtWebioEA12x6RelAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA12x6RelAlarmEntry 14 }
|
|
|
|
wtWebioEA12x6RelAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA12x6RelAlarmEntry 15 }
|
|
|
|
wtWebioEA12x6RelAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA12x6RelAlarmEntry 16 }
|
|
|
|
wtWebioEA12x6RelAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA12x6RelAlarmEntry 17 }
|
|
|
|
wtWebioEA12x6RelAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA12x6RelAlarmEntry 18 }
|
|
|
|
wtWebioEA12x6RelAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA12x6RelAlarmEntry 19 }
|
|
|
|
wtWebioEA12x6RelAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA12x6RelAlarmEntry 20 }
|
|
|
|
wtWebioEA12x6RelAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA12x6RelAlarmEntry 21 }
|
|
|
|
wtWebioEA12x6RelAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA12x6RelAlarmEntry 22 }
|
|
|
|
wtWebioEA12x6RelAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA12x6RelAlarmEntry 23 }
|
|
|
|
wtWebioEA12x6RelAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA12x6RelAlarmEntry 24 }
|
|
|
|
wtWebioEA12x6RelAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA12x6RelAlarmEntry 25 }
|
|
|
|
|
|
wtWebioEA12x6RelAlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA12x6RelAlarmEntry 26 }
|
|
|
|
wtWebioEA12x6RelAlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA12x6RelAlarmEntry 27 }
|
|
|
|
wtWebioEA12x6RelAlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA12x6RelAlarmEntry 28 }
|
|
|
|
wtWebioEA12x6RelAlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA12x6RelAlarmEntry 29 }
|
|
|
|
wtWebioEA12x6RelAlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA12x6RelAlarmEntry 30 }
|
|
|
|
wtWebioEA12x6RelAlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA12x6RelAlarmEntry 31 }
|
|
|
|
wtWebioEA12x6RelAlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA12x6RelAlarmEntry 32 }
|
|
|
|
-- wtWebioEA12x6RelPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA12x6RelInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA12x6RelPorts 1 }
|
|
|
|
wtWebioEA12x6RelInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA12x6RelInputNo }
|
|
::= { wtWebioEA12x6RelInputPortTable 1 }
|
|
|
|
WtWebioEA12x6RelInputPortEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelPortInputName OCTET STRING,
|
|
wtWebioEA12x6RelPortInputText OCTET STRING,
|
|
wtWebioEA12x6RelPortInputMode OCTET STRING,
|
|
wtWebioEA12x6RelPortInputFilter INTEGER,
|
|
wtWebioEA12x6RelPortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebioEA12x6RelPortInputBicountInactivTimeout INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA12x6RelInputPortEntry 1 }
|
|
|
|
wtWebioEA12x6RelPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA12x6RelInputPortEntry 2 }
|
|
|
|
wtWebioEA12x6RelPortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-3:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 3-7: unused
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable
|
|
|
|
Selection for inputs 4-11:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Counter clear on read
|
|
Bit 0 : Change detection enable (default)"
|
|
::= { wtWebioEA12x6RelInputPortEntry 3 }
|
|
|
|
wtWebioEA12x6RelPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA12x6RelInputPortEntry 4 }
|
|
|
|
wtWebioEA12x6RelPortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x6RelInputPortEntry 5 }
|
|
|
|
wtWebioEA12x6RelPortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebioEA12x6RelInputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA12x6RelOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA12x6RelPorts 2 }
|
|
|
|
wtWebioEA12x6RelOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA12x6RelOutputNo }
|
|
::= { wtWebioEA12x6RelOutputPortTable 1 }
|
|
|
|
WtWebioEA12x6RelOutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelPortOutputName OCTET STRING,
|
|
wtWebioEA12x6RelPortOutputText OCTET STRING,
|
|
wtWebioEA12x6RelPortOutputGroupMode OCTET STRING,
|
|
wtWebioEA12x6RelPortOutputSafetyState OCTET STRING,
|
|
wtWebioEA12x6RelPortLogicInputMask OCTET STRING,
|
|
wtWebioEA12x6RelPortLogicInputInverter OCTET STRING,
|
|
wtWebioEA12x6RelPortLogicFunction OCTET STRING,
|
|
wtWebioEA12x6RelPortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA12x6RelPortPulseDuration INTEGER,
|
|
wtWebioEA12x6RelPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA12x6RelPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA12x6RelOutputPortEntry 1 }
|
|
|
|
wtWebioEA12x6RelPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA12x6RelOutputPortEntry 2 }
|
|
|
|
wtWebioEA12x6RelPortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unused in this device 57634"
|
|
::= { wtWebioEA12x6RelOutputPortEntry 3 }
|
|
|
|
wtWebioEA12x6RelPortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH=Relais closed, 0=LOW Relais open) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebioEA12x6RelOutputPortEntry 4 }
|
|
|
|
wtWebioEA12x6RelPortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA12x6RelPortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA12x6RelPortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA12x6RelPortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA12x6RelPortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : inputs 8-11
|
|
Bit 4-7 : unused
|
|
OCTET 4:
|
|
Bit 0-7 : inputs 0-7"
|
|
::= { wtWebioEA12x6RelOutputPortEntry 5 }
|
|
|
|
wtWebioEA12x6RelPortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : inputs 8-11
|
|
Bit 4-7 : unused
|
|
OCTET 4:
|
|
Bit 0-7 : inputs 0-7"
|
|
::= { wtWebioEA12x6RelOutputPortEntry 6 }
|
|
|
|
wtWebioEA12x6RelPortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x6RelOutputPortEntry 7 }
|
|
|
|
wtWebioEA12x6RelPortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA12x6RelOutputPortEntry 8 }
|
|
|
|
wtWebioEA12x6RelPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA12x6RelOutputPortEntry 9 }
|
|
|
|
wtWebioEA12x6RelPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA12x6RelPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x6RelOutputPortEntry 10 }
|
|
|
|
-- wtWebioEA12x6RelManufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA12x6RelManufact 1 }
|
|
|
|
wtWebioEA12x6RelMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA12x6RelManufact 2 }
|
|
|
|
wtWebioEA12x6RelMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA12x6RelManufact 3 }
|
|
|
|
wtWebioEA12x6RelMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA12x6RelManufact 4 }
|
|
|
|
wtWebioEA12x6RelMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA12x6RelManufact 5 }
|
|
|
|
wtWebioEA12x6RelMfOrderNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer part number."
|
|
::= { wtWebioEA12x6RelManufact 6 }
|
|
|
|
-- wtWebioEA12x6RelDiag Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA12x6RelDiag 1 }
|
|
|
|
wtWebioEA12x6RelDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA12x6RelDiag 2 }
|
|
|
|
wtWebioEA12x6RelDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA12x6RelDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA12x6RelDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA12x6RelDiagErrorMessage."
|
|
::= { wtWebioEA12x6RelDiag 3 }
|
|
|
|
wtWebioEA12x6RelDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA12x6RelDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA12x6RelDiag 4 }
|
|
|
|
wtWebioEA12x6RelDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA12x6RelDiag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA12x6RelAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebioEA12x6RelAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebioEA12x6RelAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebioEA12x6RelAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebioEA12x6RelAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebioEA12x6RelAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebioEA12x6RelAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebioEA12x6RelAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebioEA12x6RelAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebioEA12x6RelAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebioEA12x6RelAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebioEA12x6RelAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebioEA12x6RelAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA12x6RelAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA12x6RelAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA12x6RelAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA12x6RelAlert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA12x6RelAlert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA12x6RelAlert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA12x6RelAlert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA12x6RelAlert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA12x6RelAlert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA12x6RelAlert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA12x6RelAlert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES { wtWebioEA12x6RelAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA12x6RelAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6Rel
|
|
VARIABLES {
|
|
wtWebioEA12x6RelDiagErrorIndex,
|
|
wtWebioEA12x6RelDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebAlarm6x6InOut Group
|
|
------------------------
|
|
|
|
wtWebAlarm6x6Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebAlarm6x6InOut 1 }
|
|
|
|
wtWebAlarm6x6Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent outputs."
|
|
::= { wtWebAlarm6x6InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebAlarm6x6InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebAlarm6x6InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebAlarm6x6InOut 3 }
|
|
|
|
wtWebAlarm6x6InputEntry OBJECT-TYPE
|
|
SYNTAX WtWebAlarm6x6InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebAlarm6x6InputNo }
|
|
::= { wtWebAlarm6x6InputTable 1 }
|
|
|
|
WtWebAlarm6x6InputEntry ::= SEQUENCE {
|
|
wtWebAlarm6x6InputNo INTEGER,
|
|
wtWebAlarm6x6InputCounter INTEGER,
|
|
wtWebAlarm6x6InputCounterClear INTEGER,
|
|
wtWebAlarm6x6InputState INTEGER
|
|
}
|
|
|
|
wtWebAlarm6x6InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebAlarm6x6InputEntry 1 }
|
|
|
|
wtWebAlarm6x6InputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebAlarm6x6InputEntry 2 }
|
|
|
|
wtWebAlarm6x6InputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebAlarm6x6InputEntry 3 }
|
|
|
|
wtWebAlarm6x6InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"States of the inputs, 0-OFF, 1-ON."
|
|
::= { wtWebAlarm6x6InputEntry 4 }
|
|
|
|
|
|
wtWebAlarm6x6InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-5: Digital inputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebAlarm6x6InOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebAlarm6x6OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebAlarm6x6OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebAlarm6x6InOut 5 }
|
|
|
|
wtWebAlarm6x6OutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebAlarm6x6OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebAlarm6x6OutputNo }
|
|
::= { wtWebAlarm6x6OutputTable 1 }
|
|
|
|
WtWebAlarm6x6OutputEntry ::= SEQUENCE {
|
|
wtWebAlarm6x6OutputNo INTEGER,
|
|
wtWebAlarm6x6OutputState INTEGER
|
|
}
|
|
|
|
wtWebAlarm6x6OutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebAlarm6x6OutputEntry 1 }
|
|
|
|
wtWebAlarm6x6OutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"States of the outputs, 0-OFF, 1-ON."
|
|
::= { wtWebAlarm6x6OutputEntry 2 }
|
|
|
|
wtWebAlarm6x6OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-5: Digital outputs 0-5"
|
|
::= { wtWebAlarm6x6InOut 6 }
|
|
|
|
-- Alarm Output Interface Table
|
|
|
|
wtWebAlarm6x6AlarmOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebAlarm6x6AlarmOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices.."
|
|
::= { wtWebAlarm6x6InOut 8 }
|
|
|
|
wtWebAlarm6x6AlarmOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebAlarm6x6AlarmOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index reference."
|
|
INDEX { wtWebAlarm6x6AlarmNo }
|
|
::= { wtWebAlarm6x6AlarmOutputTable 1 }
|
|
|
|
WtWebAlarm6x6AlarmOutputEntry ::= SEQUENCE {
|
|
wtWebAlarm6x6AlarmOutputState INTEGER,
|
|
wtWebAlarm6x6AlarmTriggerState INTEGER
|
|
}
|
|
|
|
wtWebAlarm6x6AlarmOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the alarm, 0-OFF, 1-ON."
|
|
::= { wtWebAlarm6x6AlarmOutputEntry 1 }
|
|
|
|
wtWebAlarm6x6AlarmTriggerState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the trigger condition, 0-OFF, 1-ON."
|
|
::= { wtWebAlarm6x6AlarmOutputEntry 2 }
|
|
|
|
-- wtWebAlarm6x6SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebAlarm6x6SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebAlarm6x6SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebAlarm6x6SessCntrl 1 }
|
|
|
|
wtWebAlarm6x6SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebAlarm6x6SessCntrl 2 }
|
|
|
|
wtWebAlarm6x6SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebAlarm6x6SessCntrl 3 }
|
|
|
|
wtWebAlarm6x6SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebAlarm6x6SessCntrl 4 }
|
|
|
|
wtWebAlarm6x6SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebAlarm6x6SessCntrl 5 }
|
|
|
|
-- wtWebAlarm6x6Text Group
|
|
------------------------
|
|
|
|
wtWebAlarm6x6DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebAlarm6x6Text 1 }
|
|
|
|
wtWebAlarm6x6DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebAlarm6x6Text 2 }
|
|
|
|
wtWebAlarm6x6DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebAlarm6x6Text 3 }
|
|
|
|
wtWebAlarm6x6DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebAlarm6x6Text 4 }
|
|
|
|
-- wtWebAlarm6x6TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebAlarm6x6TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebAlarm6x6TimeZone 1 }
|
|
|
|
wtWebAlarm6x6TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebAlarm6x6TimeZone 2 }
|
|
|
|
wtWebAlarm6x6TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebAlarm6x6TimeZone 3 }
|
|
|
|
wtWebAlarm6x6StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebAlarm6x6TimeZone 4 }
|
|
|
|
wtWebAlarm6x6StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebAlarm6x6TimeZone 5 }
|
|
|
|
wtWebAlarm6x6StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebAlarm6x6TimeZone 6 }
|
|
|
|
wtWebAlarm6x6StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebAlarm6x6StartMonth-January(1),
|
|
wtWebAlarm6x6StartMonth-February(2),
|
|
wtWebAlarm6x6StartMonth-March(3),
|
|
wtWebAlarm6x6StartMonth-April(4),
|
|
wtWebAlarm6x6StartMonth-May(5),
|
|
wtWebAlarm6x6StartMonth-June(6),
|
|
wtWebAlarm6x6StartMonth-July(7),
|
|
wtWebAlarm6x6StartMonth-August(8),
|
|
wtWebAlarm6x6StartMonth-September(9),
|
|
wtWebAlarm6x6StartMonth-October(10),
|
|
wtWebAlarm6x6StartMonth-November(11),
|
|
wtWebAlarm6x6StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebAlarm6x6TimeZone 7 }
|
|
|
|
wtWebAlarm6x6StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebAlarm6x6StartMode-first(1),
|
|
wtWebAlarm6x6StartMode-second(2),
|
|
wtWebAlarm6x6StartMode-third(3),
|
|
wtWebAlarm6x6StartMode-fourth(4),
|
|
wtWebAlarm6x6StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebAlarm6x6TimeZone 8 }
|
|
|
|
wtWebAlarm6x6StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebAlarm6x6StartWday-Sunday(1),
|
|
wtWebAlarm6x6StartWday-Monday(2),
|
|
wtWebAlarm6x6StartWday-Tuesday(3),
|
|
wtWebAlarm6x6StartWday-Thursday(4),
|
|
wtWebAlarm6x6StartWday-Wednesday(5),
|
|
wtWebAlarm6x6StartWday-Friday(6),
|
|
wtWebAlarm6x6StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebAlarm6x6TimeZone 9 }
|
|
|
|
wtWebAlarm6x6StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebAlarm6x6TimeZone 10 }
|
|
|
|
wtWebAlarm6x6StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebAlarm6x6TimeZone 11 }
|
|
|
|
wtWebAlarm6x6StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebAlarm6x6StopMonth-January(1),
|
|
wtWebAlarm6x6StopMonth-February(2),
|
|
wtWebAlarm6x6StopMonth-March(3),
|
|
wtWebAlarm6x6StopMonth-April(4),
|
|
wtWebAlarm6x6StopMonth-May(5),
|
|
wtWebAlarm6x6StopMonth-June(6),
|
|
wtWebAlarm6x6StopMonth-July(7),
|
|
wtWebAlarm6x6StopMonth-August(8),
|
|
wtWebAlarm6x6StopMonth-September(9),
|
|
wtWebAlarm6x6StopMonth-October(10),
|
|
wtWebAlarm6x6StopMonth-November(11),
|
|
wtWebAlarm6x6StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebAlarm6x6TimeZone 12 }
|
|
|
|
wtWebAlarm6x6StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebAlarm6x6StopMode-first(1),
|
|
wtWebAlarm6x6StopMode-second(2),
|
|
wtWebAlarm6x6StopMode-third(3),
|
|
wtWebAlarm6x6StopMode-fourth(4),
|
|
wtWebAlarm6x6StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebAlarm6x6TimeZone 13 }
|
|
|
|
wtWebAlarm6x6StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebAlarm6x6StopWday-Sunday(1),
|
|
wtWebAlarm6x6StopWday-Monday(2),
|
|
wtWebAlarm6x6StopWday-Tuesday(3),
|
|
wtWebAlarm6x6StopWday-Thursday(4),
|
|
wtWebAlarm6x6StopWday-Wednesday(5),
|
|
wtWebAlarm6x6StopWday-Friday(6),
|
|
wtWebAlarm6x6StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebAlarm6x6TimeZone 14 }
|
|
|
|
wtWebAlarm6x6StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebAlarm6x6TimeZone 15 }
|
|
|
|
wtWebAlarm6x6StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebAlarm6x6TimeZone 16 }
|
|
|
|
-- wtWebAlarm6x6TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebAlarm6x6TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebAlarm6x6TimeServer 1 }
|
|
|
|
wtWebAlarm6x6TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebAlarm6x6TimeServer 2 }
|
|
|
|
wtWebAlarm6x6TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebAlarm6x6TimeServer 3 }
|
|
|
|
wtWebAlarm6x6TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebAlarm6x6TimeServer 4 }
|
|
|
|
|
|
-- wtWebAlarm6x6DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebAlarm6x6ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebAlarm6x6DeviceClock 1 }
|
|
|
|
wtWebAlarm6x6ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebAlarm6x6DeviceClock 2 }
|
|
|
|
wtWebAlarm6x6ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebAlarm6x6DeviceClock 3 }
|
|
|
|
wtWebAlarm6x6ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebAlarm6x6ClockMonth-January(1),
|
|
wtWebAlarm6x6ClockMonth-February(2),
|
|
wtWebAlarm6x6ClockMonth-March(3),
|
|
wtWebAlarm6x6ClockMonth-April(4),
|
|
wtWebAlarm6x6ClockMonth-May(5),
|
|
wtWebAlarm6x6ClockMonth-June(6),
|
|
wtWebAlarm6x6ClockMonth-July(7),
|
|
wtWebAlarm6x6ClockMonth-August(8),
|
|
wtWebAlarm6x6ClockMonth-September(9),
|
|
wtWebAlarm6x6ClockMonth-October(10),
|
|
wtWebAlarm6x6ClockMonth-November(11),
|
|
wtWebAlarm6x6ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebAlarm6x6DeviceClock 4 }
|
|
|
|
wtWebAlarm6x6ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebAlarm6x6DeviceClock 5 }
|
|
|
|
-- wtWebAlarm6x6Network Group
|
|
------------------------
|
|
|
|
wtWebAlarm6x6IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebAlarm6x6Network 1 }
|
|
|
|
wtWebAlarm6x6SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebAlarm6x6Network 2 }
|
|
|
|
wtWebAlarm6x6Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebAlarm6x6Network 3 }
|
|
|
|
wtWebAlarm6x6DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebAlarm6x6Network 4 }
|
|
|
|
wtWebAlarm6x6DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebAlarm6x6Network 5 }
|
|
|
|
wtWebAlarm6x6AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebAlarm6x6Network 6 }
|
|
|
|
-- wtWebAlarm6x6HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebAlarm6x6HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebAlarm6x6HTTP 4 }
|
|
|
|
|
|
-- wtWebAlarm6x6Mail Group
|
|
--------------------------------
|
|
|
|
wtWebAlarm6x6MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebAlarm6x6Mail 1 }
|
|
|
|
wtWebAlarm6x6MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebAlarm6x6Mail 2 }
|
|
|
|
wtWebAlarm6x6MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebAlarm6x6Mail 3 }
|
|
|
|
wtWebAlarm6x6MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebAlarm6x6Mail 4 }
|
|
|
|
wtWebAlarm6x6MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebAlarm6x6Mail 5 }
|
|
|
|
wtWebAlarm6x6MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebAlarm6x6Mail 6 }
|
|
|
|
wtWebAlarm6x6MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebAlarm6x6Mail 7 }
|
|
|
|
wtWebAlarm6x6MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebAlarm6x6Mail 8 }
|
|
|
|
|
|
-- wtWebAlarm6x6Snmp Group
|
|
--------------------------------
|
|
|
|
wtWebAlarm6x6SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebAlarm6x6SNMP 1 }
|
|
|
|
wtWebAlarm6x6SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebAlarm6x6SNMP 2 }
|
|
|
|
wtWebAlarm6x6SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebAlarm6x6SNMP 3 }
|
|
|
|
wtWebAlarm6x6SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebAlarm6x6SNMP 4 }
|
|
|
|
wtWebAlarm6x6SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebAlarm6x6SNMP 5 }
|
|
|
|
-- wtWebAlarm6x6Udp Group
|
|
--------------------------------
|
|
|
|
wtWebAlarm6x6UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebAlarm6x6UDP 1 }
|
|
|
|
wtWebAlarm6x6UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebAlarm6x6UDP 2 }
|
|
|
|
wtWebAlarm6x6UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebAlarm6x6UDP 3 }
|
|
|
|
-- wtWebAlarm6x6Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebAlarm6x6SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebAlarm6x6Syslog 1 }
|
|
|
|
wtWebAlarm6x6SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebAlarm6x6Syslog 2 }
|
|
|
|
wtWebAlarm6x6SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebAlarm6x6Syslog 3 }
|
|
|
|
wtWebAlarm6x6SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebAlarm6x6Syslog 4 }
|
|
|
|
-- wtWebAlarm6x6FTP Group
|
|
--------------------------------
|
|
|
|
wtWebAlarm6x6FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebAlarm6x6FTP 1 }
|
|
|
|
wtWebAlarm6x6FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebAlarm6x6FTP 2 }
|
|
|
|
wtWebAlarm6x6FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebAlarm6x6FTP 3 }
|
|
|
|
wtWebAlarm6x6FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebAlarm6x6FTP 4 }
|
|
|
|
wtWebAlarm6x6FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebAlarm6x6FTP 5 }
|
|
|
|
wtWebAlarm6x6FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebAlarm6x6FTP 6 }
|
|
|
|
wtWebAlarm6x6FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebAlarm6x6FTP 7 }
|
|
|
|
-- wtWebAlarm6x6Alarm Group
|
|
----------------------------
|
|
|
|
wtWebAlarm6x6AlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebAlarm6x6Alarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebAlarm6x6AlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebAlarm6x6AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebAlarm6x6Alarm 2 }
|
|
|
|
wtWebAlarm6x6AlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebAlarm6x6AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebAlarm6x6AlarmNo }
|
|
::= { wtWebAlarm6x6AlarmIfTable 1 }
|
|
|
|
WtWebAlarm6x6AlarmIfEntry ::= SEQUENCE {
|
|
wtWebAlarm6x6AlarmNo INTEGER
|
|
}
|
|
|
|
wtWebAlarm6x6AlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebAlarm6x6AlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebAlarm6x6AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebAlarm6x6AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebAlarm6x6Alarm 3 }
|
|
|
|
wtWebAlarm6x6AlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebAlarm6x6AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebAlarm6x6AlarmNo }
|
|
::= { wtWebAlarm6x6AlarmTable 1 }
|
|
|
|
WtWebAlarm6x6AlarmEntry ::= SEQUENCE {
|
|
wtWebAlarm6x6AlarmInputTrigger OCTET STRING,
|
|
wtWebAlarm6x6AlarmMaxCounterValue OCTET STRING,
|
|
wtWebAlarm6x6AlarmInterval OCTET STRING,
|
|
wtWebAlarm6x6AlarmEnable OCTET STRING,
|
|
wtWebAlarm6x6AlarmMailAddr OCTET STRING,
|
|
wtWebAlarm6x6AlarmMailSubject OCTET STRING,
|
|
wtWebAlarm6x6AlarmMailText OCTET STRING,
|
|
wtWebAlarm6x6AlarmSnmpManagerIP OCTET STRING,
|
|
wtWebAlarm6x6AlarmSnmpTrapText OCTET STRING,
|
|
wtWebAlarm6x6AlarmUdpIpAddr OCTET STRING,
|
|
wtWebAlarm6x6AlarmUdpPort INTEGER,
|
|
wtWebAlarm6x6AlarmUdpText OCTET STRING,
|
|
wtWebAlarm6x6AlarmTcpIpAddr OCTET STRING,
|
|
wtWebAlarm6x6AlarmTcpPort INTEGER,
|
|
wtWebAlarm6x6AlarmTcpText OCTET STRING,
|
|
wtWebAlarm6x6AlarmSyslogIpAddr OCTET STRING,
|
|
wtWebAlarm6x6AlarmSyslogPort INTEGER,
|
|
wtWebAlarm6x6AlarmSyslogText OCTET STRING,
|
|
wtWebAlarm6x6AlarmFtpDataPort OCTET STRING,
|
|
wtWebAlarm6x6AlarmFtpFileName OCTET STRING,
|
|
wtWebAlarm6x6AlarmFtpText OCTET STRING,
|
|
wtWebAlarm6x6AlarmFtpOption OCTET STRING,
|
|
|
|
wtWebAlarm6x6AlarmMailReleaseSubject OCTET STRING,
|
|
wtWebAlarm6x6AlarmMailReleaseText OCTET STRING,
|
|
wtWebAlarm6x6AlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebAlarm6x6AlarmUdpReleaseText OCTET STRING,
|
|
wtWebAlarm6x6AlarmTcpReleaseText OCTET STRING,
|
|
wtWebAlarm6x6AlarmSyslogReleaseText OCTET STRING,
|
|
wtWebAlarm6x6AlarmFtpReleaseText OCTET STRING,
|
|
|
|
wtWebAlarm6x6AlarmName OCTET STRING,
|
|
wtWebAlarm6x6AlarmGlobalEnable OCTET STRING,
|
|
wtWebAlarm6x6AlarmCounterClear OCTET STRING,
|
|
wtWebAlarm6x6AlarmAckEnable OCTET STRING,
|
|
wtWebAlarm6x6AlarmAckPort INTEGER,
|
|
wtWebAlarm6x6AlarmSetPort INTEGER,
|
|
|
|
wtWebAlarm6x6AlarmMailTrgClearSubject OCTET STRING,
|
|
wtWebAlarm6x6AlarmMailTrgClearText OCTET STRING,
|
|
wtWebAlarm6x6AlarmSnmpTrapTrgClearText OCTET STRING,
|
|
wtWebAlarm6x6AlarmUdpTrgClearText OCTET STRING,
|
|
wtWebAlarm6x6AlarmTcpTrgClearText OCTET STRING,
|
|
wtWebAlarm6x6AlarmSyslogTrgClearText OCTET STRING,
|
|
wtWebAlarm6x6AlarmFtpTrgClearText OCTET STRING,
|
|
|
|
wtWebAlarm6x6AlarmMailTrapTxEnable OCTET STRING,
|
|
wtWebAlarm6x6AlarmSnmpTrapTrapTxEnable OCTET STRING,
|
|
wtWebAlarm6x6AlarmUdpTrapTxEnable OCTET STRING,
|
|
wtWebAlarm6x6AlarmTcpTrapTxEnable OCTET STRING,
|
|
wtWebAlarm6x6AlarmSyslogTrapTxEnable OCTET STRING,
|
|
wtWebAlarm6x6AlarmFtpTrapTxEnable OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebAlarm6x6AlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-5: Mask for digital inputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-5: Level of digital inputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 9-12 contain the counter bit (1=ON, 0=OFF). Inputs masked with the counter bit trigger an alarm
|
|
when the corresponding counter reaching the wtWebAlarm6x6AlarmMaxCounterValue. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-5: Counter bits of digital inputs 0-5
|
|
Bit 6-7: unused."
|
|
|
|
::= { wtWebAlarm6x6AlarmEntry 1 }
|
|
|
|
wtWebAlarm6x6AlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebAlarm6x6AlarmInputTrigger are not considered."
|
|
::= { wtWebAlarm6x6AlarmEntry 4 }
|
|
|
|
wtWebAlarm6x6AlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebAlarm6x6AlarmEntry 5 }
|
|
|
|
wtWebAlarm6x6AlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Output Switch Enable
|
|
Bit 1: Mail Enable
|
|
Bit 2: SNMP Trap enable
|
|
Bit 3: UDP enable
|
|
Bit 4: unused
|
|
Bit 5: TCP Client enable
|
|
Bit 6: Syslog Messages enable
|
|
Bit 7: FTP Client enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 6 }
|
|
|
|
wtWebAlarm6x6AlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebAlarm6x6AlarmEntry 7 }
|
|
|
|
wtWebAlarm6x6AlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebAlarm6x6AlarmEntry 8 }
|
|
|
|
wtWebAlarm6x6AlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebAlarm6x6AlarmEntry 9 }
|
|
|
|
wtWebAlarm6x6AlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebAlarm6x6AlarmEntry 10 }
|
|
|
|
wtWebAlarm6x6AlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 11 }
|
|
|
|
wtWebAlarm6x6AlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebAlarm6x6AlarmEntry 12 }
|
|
|
|
wtWebAlarm6x6AlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebAlarm6x6AlarmEntry 13 }
|
|
|
|
wtWebAlarm6x6AlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 14 }
|
|
|
|
wtWebAlarm6x6AlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebAlarm6x6AlarmEntry 15 }
|
|
|
|
wtWebAlarm6x6AlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebAlarm6x6AlarmEntry 16 }
|
|
|
|
wtWebAlarm6x6AlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 17 }
|
|
|
|
wtWebAlarm6x6AlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebAlarm6x6AlarmEntry 18 }
|
|
|
|
wtWebAlarm6x6AlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebAlarm6x6AlarmEntry 19 }
|
|
|
|
wtWebAlarm6x6AlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebAlarm6x6AlarmEntry 20 }
|
|
|
|
wtWebAlarm6x6AlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebAlarm6x6AlarmEntry 21 }
|
|
|
|
wtWebAlarm6x6AlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebAlarm6x6AlarmEntry 22 }
|
|
|
|
wtWebAlarm6x6AlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebAlarm6x6AlarmEntry 23 }
|
|
|
|
wtWebAlarm6x6AlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebAlarm6x6AlarmEntry 24 }
|
|
|
|
wtWebAlarm6x6AlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebAlarm6x6AlarmEntry 26 }
|
|
|
|
wtWebAlarm6x6AlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebAlarm6x6AlarmEntry 27 }
|
|
|
|
wtWebAlarm6x6AlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 28 }
|
|
|
|
wtWebAlarm6x6AlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 29 }
|
|
|
|
wtWebAlarm6x6AlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 30 }
|
|
|
|
wtWebAlarm6x6AlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebAlarm6x6AlarmEntry 31 }
|
|
|
|
wtWebAlarm6x6AlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebAlarm6x6AlarmEntry 32 }
|
|
|
|
wtWebAlarm6x6AlarmName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the alarm."
|
|
::= { wtWebAlarm6x6AlarmEntry 33 }
|
|
|
|
wtWebAlarm6x6AlarmGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
Die OCTETS werden bitweise interpretiert.
|
|
Bit 0 entspricht dem LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Alarm enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 34 }
|
|
|
|
wtWebAlarm6x6AlarmCounterClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Counter clear on Alarm acknowledge
|
|
Bit 0 : Counter clear on Alarm send"
|
|
::= { wtWebAlarm6x6AlarmEntry 35 }
|
|
|
|
|
|
wtWebAlarm6x6AlarmAckEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Software acknowledge enable
|
|
Bit 0 : Hardware acknowledge enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 36 }
|
|
|
|
|
|
wtWebAlarm6x6AlarmAckPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the input, which clears the alarm (1-6)."
|
|
::= { wtWebAlarm6x6AlarmEntry 37 }
|
|
|
|
wtWebAlarm6x6AlarmSetPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the output, which will be set by this alarm (1-6).
|
|
The configuration of pulse mode and polarity defined in the port output section is used."
|
|
::= { wtWebAlarm6x6AlarmEntry 38 }
|
|
|
|
wtWebAlarm6x6AlarmMailTrgClearSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebAlarm6x6AlarmEntry 39 }
|
|
|
|
wtWebAlarm6x6AlarmMailTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebAlarm6x6AlarmEntry 40 }
|
|
|
|
wtWebAlarm6x6AlarmSnmpTrapTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 41 }
|
|
|
|
wtWebAlarm6x6AlarmUdpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 42 }
|
|
|
|
wtWebAlarm6x6AlarmTcpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebAlarm6x6AlarmEntry 43 }
|
|
|
|
wtWebAlarm6x6AlarmSyslogTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebAlarm6x6AlarmEntry 44 }
|
|
|
|
wtWebAlarm6x6AlarmFtpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebAlarm6x6AlarmEntry 45 }
|
|
|
|
wtWebAlarm6x6AlarmMailTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 46 }
|
|
|
|
wtWebAlarm6x6AlarmSnmpTrapTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 47 }
|
|
|
|
wtWebAlarm6x6AlarmUdpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 48 }
|
|
|
|
wtWebAlarm6x6AlarmTcpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 49 }
|
|
|
|
wtWebAlarm6x6AlarmSyslogTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 50 }
|
|
|
|
wtWebAlarm6x6AlarmFtpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtWebAlarm6x6AlarmEntry 51 }
|
|
|
|
|
|
-- wtWebAlarm6x6Ports Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebAlarm6x6InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebAlarm6x6InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebAlarm6x6Ports 1 }
|
|
|
|
wtWebAlarm6x6InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebAlarm6x6InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebAlarm6x6InputNo }
|
|
::= { wtWebAlarm6x6InputPortTable 1 }
|
|
|
|
WtWebAlarm6x6InputPortEntry ::= SEQUENCE {
|
|
wtWebAlarm6x6PortInputName OCTET STRING,
|
|
wtWebAlarm6x6PortInputText OCTET STRING,
|
|
wtWebAlarm6x6PortInputFilter INTEGER,
|
|
wtWebAlarm6x6PortInputPulsePolarity OCTET STRING,
|
|
wtWebAlarm6x6PortInputCounterSet INTEGER
|
|
|
|
}
|
|
|
|
wtWebAlarm6x6PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebAlarm6x6InputPortEntry 1 }
|
|
|
|
wtWebAlarm6x6PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebAlarm6x6InputPortEntry 2 }
|
|
|
|
|
|
wtWebAlarm6x6PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebAlarm6x6InputPortEntry 4 }
|
|
|
|
wtWebAlarm6x6PortInputPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebAlarm6x6InputPortEntry 5 }
|
|
|
|
wtWebAlarm6x6PortInputCounterSet OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing to this variable presets the counter, while reading returns the actual value."
|
|
::= { wtWebAlarm6x6InputPortEntry 7 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebAlarm6x6OutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebAlarm6x6OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebAlarm6x6Ports 2 }
|
|
|
|
wtWebAlarm6x6OutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebAlarm6x6OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebAlarm6x6OutputNo }
|
|
::= { wtWebAlarm6x6OutputPortTable 1 }
|
|
|
|
WtWebAlarm6x6OutputPortEntry ::= SEQUENCE {
|
|
wtWebAlarm6x6PortOutputName OCTET STRING,
|
|
wtWebAlarm6x6PortOutputText OCTET STRING,
|
|
wtWebAlarm6x6PortPulseDuration INTEGER,
|
|
wtWebAlarm6x6PortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebAlarm6x6PortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebAlarm6x6OutputPortEntry 1 }
|
|
|
|
wtWebAlarm6x6PortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebAlarm6x6OutputPortEntry 2 }
|
|
|
|
wtWebAlarm6x6PortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/100 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebAlarm6x6OutputPortEntry 9 }
|
|
|
|
wtWebAlarm6x6PortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebAlarm6x6PortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebAlarm6x6OutputPortEntry 10 }
|
|
|
|
-- wtWebAlarm6x6Manufact Group
|
|
----------------------------
|
|
|
|
wtWebAlarm6x6MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebAlarm6x6Manufact 1 }
|
|
|
|
wtWebAlarm6x6MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebAlarm6x6Manufact 2 }
|
|
|
|
wtWebAlarm6x6MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebAlarm6x6Manufact 3 }
|
|
|
|
wtWebAlarm6x6MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebAlarm6x6Manufact 4 }
|
|
|
|
wtWebAlarm6x6MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebAlarm6x6Manufact 5 }
|
|
|
|
wtWebAlarm6x6MfOrderNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer part number."
|
|
::= { wtWebAlarm6x6Manufact 6 }
|
|
|
|
-- wtWebAlarm6x6Diag Group
|
|
----------------------------
|
|
|
|
wtWebAlarm6x6DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebAlarm6x6Diag 1 }
|
|
|
|
wtWebAlarm6x6DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebAlarm6x6Diag 2 }
|
|
|
|
wtWebAlarm6x6DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebAlarm6x6DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebAlarm6x6DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebAlarm6x6DiagErrorMessage."
|
|
::= { wtWebAlarm6x6Diag 3 }
|
|
|
|
wtWebAlarm6x6DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebAlarm6x6DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebAlarm6x6Diag 4 }
|
|
|
|
wtWebAlarm6x6DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebAlarm6x6Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebAlarm6x6Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebAlarm6x6Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebAlarm6x6Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebAlarm6x6Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebAlarm6x6Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebAlarm6x6Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebAlarm6x6Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebAlarm6x6Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebAlarm6x6Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebAlarm6x6Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebAlarm6x6Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebAlarm6x6Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebAlarm6x6Alert13 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebAlarm6x6Alert14 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebAlarm6x6Alert15 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebAlarm6x6Alert16 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebAlarm6x6Alert17 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebAlarm6x6Alert18 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebAlarm6x6Alert19 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebAlarm6x6Alert20 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebAlarm6x6Alert21 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebAlarm6x6Alert22 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebAlarm6x6Alert23 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebAlarm6x6Alert24 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebAlarm6x6Alert25 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 91
|
|
|
|
wtWebAlarm6x6Alert26 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 92
|
|
|
|
wtWebAlarm6x6Alert27 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 93
|
|
|
|
wtWebAlarm6x6Alert28 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 94
|
|
|
|
wtWebAlarm6x6Alert29 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 95
|
|
|
|
wtWebAlarm6x6Alert30 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 96
|
|
|
|
wtWebAlarm6x6Alert31 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 97
|
|
|
|
wtWebAlarm6x6Alert32 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 98
|
|
|
|
wtWebAlarm6x6Alert33 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 99
|
|
|
|
wtWebAlarm6x6Alert34 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 100
|
|
|
|
wtWebAlarm6x6Alert35 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 101
|
|
|
|
wtWebAlarm6x6Alert36 TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES { wtWebAlarm6x6AlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 102
|
|
|
|
wtWebAlarm6x6AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebAlarm6x6
|
|
VARIABLES {
|
|
wtWebAlarm6x6DiagErrorIndex,
|
|
wtWebAlarm6x6DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebAlarm Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebCount6InOut Group
|
|
------------------------
|
|
|
|
wtWebCount6Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebCount6InOut 1 }
|
|
|
|
wtWebCount6Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent outputs."
|
|
::= { wtWebCount6InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebCount6InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebCount6InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebCount6InOut 3 }
|
|
|
|
wtWebCount6InputEntry OBJECT-TYPE
|
|
SYNTAX WtWebCount6InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebCount6InputNo }
|
|
::= { wtWebCount6InputTable 1 }
|
|
|
|
WtWebCount6InputEntry ::= SEQUENCE {
|
|
wtWebCount6InputNo INTEGER,
|
|
wtWebCount6InputCounter INTEGER,
|
|
wtWebCount6InputCounterClear INTEGER,
|
|
wtWebCount6InputState INTEGER
|
|
}
|
|
|
|
wtWebCount6InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebCount6InputEntry 1 }
|
|
|
|
wtWebCount6InputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebCount6InputEntry 2 }
|
|
|
|
wtWebCount6InputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebCount6InputEntry 3 }
|
|
|
|
wtWebCount6InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Tates of the inputs, 0-OFF, 1-ON."
|
|
::= { wtWebCount6InputEntry 4 }
|
|
|
|
wtWebCount6InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-5: Digital inputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebCount6InOut 4 }
|
|
|
|
-- Report Output Interface Table
|
|
|
|
wtWebCount6ReportOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebCount6ReportOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of Report indices.."
|
|
::= { wtWebCount6InOut 8 }
|
|
|
|
wtWebCount6ReportOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebCount6ReportOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index reference."
|
|
INDEX { wtWebCount6ReportNo }
|
|
::= { wtWebCount6ReportOutputTable 1 }
|
|
|
|
WtWebCount6ReportOutputEntry ::= SEQUENCE {
|
|
wtWebCount6ReportOutputState INTEGER,
|
|
wtWebCount6ReportTriggerState INTEGER
|
|
}
|
|
|
|
wtWebCount6ReportOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the Report, 0-OFF, 1-ON."
|
|
::= { wtWebCount6ReportOutputEntry 1 }
|
|
|
|
wtWebCount6ReportTriggerState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the trigger condition, 0-OFF, 1-ON."
|
|
::= { wtWebCount6ReportOutputEntry 2 }
|
|
|
|
-- wtWebCount6SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebCount6SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebCount6SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebCount6SessCntrl 1 }
|
|
|
|
wtWebCount6SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebCount6SessCntrl 2 }
|
|
|
|
wtWebCount6SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebCount6SessCntrl 3 }
|
|
|
|
wtWebCount6SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebCount6SessCntrl 4 }
|
|
|
|
wtWebCount6SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebCount6SessCntrl 5 }
|
|
|
|
-- wtWebCount6Text Group
|
|
------------------------
|
|
|
|
wtWebCount6DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebCount6Text 1 }
|
|
|
|
wtWebCount6DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebCount6Text 2 }
|
|
|
|
wtWebCount6DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebCount6Text 3 }
|
|
|
|
wtWebCount6DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebCount6Text 4 }
|
|
|
|
-- wtWebCount6TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebCount6TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebCount6TimeZone 1 }
|
|
|
|
wtWebCount6TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebCount6TimeZone 2 }
|
|
|
|
wtWebCount6TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebCount6TimeZone 3 }
|
|
|
|
wtWebCount6StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebCount6TimeZone 4 }
|
|
|
|
wtWebCount6StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebCount6TimeZone 5 }
|
|
|
|
wtWebCount6StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebCount6TimeZone 6 }
|
|
|
|
wtWebCount6StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebCount6StartMonth-January(1),
|
|
wtWebCount6StartMonth-February(2),
|
|
wtWebCount6StartMonth-March(3),
|
|
wtWebCount6StartMonth-April(4),
|
|
wtWebCount6StartMonth-May(5),
|
|
wtWebCount6StartMonth-June(6),
|
|
wtWebCount6StartMonth-July(7),
|
|
wtWebCount6StartMonth-August(8),
|
|
wtWebCount6StartMonth-September(9),
|
|
wtWebCount6StartMonth-October(10),
|
|
wtWebCount6StartMonth-November(11),
|
|
wtWebCount6StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebCount6TimeZone 7 }
|
|
|
|
wtWebCount6StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebCount6StartMode-first(1),
|
|
wtWebCount6StartMode-second(2),
|
|
wtWebCount6StartMode-third(3),
|
|
wtWebCount6StartMode-fourth(4),
|
|
wtWebCount6StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebCount6TimeZone 8 }
|
|
|
|
wtWebCount6StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebCount6StartWday-Sunday(1),
|
|
wtWebCount6StartWday-Monday(2),
|
|
wtWebCount6StartWday-Tuesday(3),
|
|
wtWebCount6StartWday-Thursday(4),
|
|
wtWebCount6StartWday-Wednesday(5),
|
|
wtWebCount6StartWday-Friday(6),
|
|
wtWebCount6StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebCount6TimeZone 9 }
|
|
|
|
wtWebCount6StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebCount6TimeZone 10 }
|
|
|
|
wtWebCount6StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebCount6TimeZone 11 }
|
|
|
|
wtWebCount6StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebCount6StopMonth-January(1),
|
|
wtWebCount6StopMonth-February(2),
|
|
wtWebCount6StopMonth-March(3),
|
|
wtWebCount6StopMonth-April(4),
|
|
wtWebCount6StopMonth-May(5),
|
|
wtWebCount6StopMonth-June(6),
|
|
wtWebCount6StopMonth-July(7),
|
|
wtWebCount6StopMonth-August(8),
|
|
wtWebCount6StopMonth-September(9),
|
|
wtWebCount6StopMonth-October(10),
|
|
wtWebCount6StopMonth-November(11),
|
|
wtWebCount6StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebCount6TimeZone 12 }
|
|
|
|
wtWebCount6StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebCount6StopMode-first(1),
|
|
wtWebCount6StopMode-second(2),
|
|
wtWebCount6StopMode-third(3),
|
|
wtWebCount6StopMode-fourth(4),
|
|
wtWebCount6StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebCount6TimeZone 13 }
|
|
|
|
wtWebCount6StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebCount6StopWday-Sunday(1),
|
|
wtWebCount6StopWday-Monday(2),
|
|
wtWebCount6StopWday-Tuesday(3),
|
|
wtWebCount6StopWday-Thursday(4),
|
|
wtWebCount6StopWday-Wednesday(5),
|
|
wtWebCount6StopWday-Friday(6),
|
|
wtWebCount6StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebCount6TimeZone 14 }
|
|
|
|
wtWebCount6StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebCount6TimeZone 15 }
|
|
|
|
wtWebCount6StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebCount6TimeZone 16 }
|
|
|
|
-- wtWebCount6TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebCount6TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebCount6TimeServer 1 }
|
|
|
|
wtWebCount6TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebCount6TimeServer 2 }
|
|
|
|
wtWebCount6TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebCount6TimeServer 3 }
|
|
|
|
wtWebCount6TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebCount6TimeServer 4 }
|
|
|
|
|
|
-- wtWebCount6DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebCount6ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebCount6DeviceClock 1 }
|
|
|
|
wtWebCount6ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebCount6DeviceClock 2 }
|
|
|
|
wtWebCount6ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebCount6DeviceClock 3 }
|
|
|
|
wtWebCount6ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebCount6ClockMonth-January(1),
|
|
wtWebCount6ClockMonth-February(2),
|
|
wtWebCount6ClockMonth-March(3),
|
|
wtWebCount6ClockMonth-April(4),
|
|
wtWebCount6ClockMonth-May(5),
|
|
wtWebCount6ClockMonth-June(6),
|
|
wtWebCount6ClockMonth-July(7),
|
|
wtWebCount6ClockMonth-August(8),
|
|
wtWebCount6ClockMonth-September(9),
|
|
wtWebCount6ClockMonth-October(10),
|
|
wtWebCount6ClockMonth-November(11),
|
|
wtWebCount6ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebCount6DeviceClock 4 }
|
|
|
|
wtWebCount6ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebCount6DeviceClock 5 }
|
|
|
|
-- wtWebCount6Network Group
|
|
------------------------
|
|
|
|
wtWebCount6IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebCount6Network 1 }
|
|
|
|
wtWebCount6SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebCount6Network 2 }
|
|
|
|
wtWebCount6Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebCount6Network 3 }
|
|
|
|
wtWebCount6DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebCount6Network 4 }
|
|
|
|
wtWebCount6DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebCount6Network 5 }
|
|
|
|
wtWebCount6AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebCount6Network 6 }
|
|
|
|
-- wtWebCount6HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebCount6HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebCount6HTTP 4 }
|
|
|
|
|
|
-- wtWebCount6Mail Group
|
|
--------------------------------
|
|
|
|
wtWebCount6MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebCount6Mail 1 }
|
|
|
|
wtWebCount6MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebCount6Mail 2 }
|
|
|
|
wtWebCount6MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebCount6Mail 3 }
|
|
|
|
wtWebCount6MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebCount6Mail 4 }
|
|
|
|
wtWebCount6MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebCount6Mail 5 }
|
|
|
|
wtWebCount6MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebCount6Mail 6 }
|
|
|
|
wtWebCount6MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebCount6Mail 7 }
|
|
|
|
wtWebCount6MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebCount6Mail 8 }
|
|
|
|
|
|
-- wtWebCount6Snmp Group
|
|
--------------------------------
|
|
|
|
wtWebCount6SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebCount6SNMP 1 }
|
|
|
|
wtWebCount6SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebCount6SNMP 2 }
|
|
|
|
wtWebCount6SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebCount6SNMP 3 }
|
|
|
|
wtWebCount6SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebCount6SNMP 4 }
|
|
|
|
wtWebCount6SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebCount6SNMP 5 }
|
|
|
|
-- wtWebCount6Udp Group
|
|
--------------------------------
|
|
|
|
wtWebCount6UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebCount6UDP 1 }
|
|
|
|
wtWebCount6UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebCount6UDP 2 }
|
|
|
|
wtWebCount6UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebCount6UDP 3 }
|
|
|
|
-- wtWebCount6Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebCount6SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebCount6Syslog 1 }
|
|
|
|
wtWebCount6SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebCount6Syslog 2 }
|
|
|
|
wtWebCount6SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebCount6Syslog 3 }
|
|
|
|
wtWebCount6SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebCount6Syslog 4 }
|
|
|
|
-- wtWebCount6FTP Group
|
|
--------------------------------
|
|
|
|
wtWebCount6FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebCount6FTP 1 }
|
|
|
|
wtWebCount6FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebCount6FTP 2 }
|
|
|
|
wtWebCount6FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebCount6FTP 3 }
|
|
|
|
wtWebCount6FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebCount6FTP 4 }
|
|
|
|
wtWebCount6FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebCount6FTP 5 }
|
|
|
|
wtWebCount6FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebCount6FTP 6 }
|
|
|
|
wtWebCount6FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebCount6FTP 7 }
|
|
|
|
-- wtWebCount6Report Group
|
|
----------------------------
|
|
|
|
wtWebCount6ReportCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent Reports."
|
|
::= { wtWebCount6Report 1 }
|
|
|
|
-- Report Interface Table
|
|
|
|
wtWebCount6ReportIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebCount6ReportIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of Report indices."
|
|
::= { wtWebCount6Report 2 }
|
|
|
|
wtWebCount6ReportIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebCount6ReportIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the Reports."
|
|
INDEX { wtWebCount6ReportNo }
|
|
::= { wtWebCount6ReportIfTable 1 }
|
|
|
|
WtWebCount6ReportIfEntry ::= SEQUENCE {
|
|
wtWebCount6ReportNo INTEGER
|
|
}
|
|
|
|
wtWebCount6ReportNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the Reports."
|
|
::= { wtWebCount6ReportIfEntry 1 }
|
|
|
|
-- Report Table
|
|
|
|
wtWebCount6ReportTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebCount6ReportEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the Report number."
|
|
::= { wtWebCount6Report 3 }
|
|
|
|
wtWebCount6ReportEntry OBJECT-TYPE
|
|
SYNTAX WtWebCount6ReportEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Report parameters of the individual Reports."
|
|
INDEX { wtWebCount6ReportNo }
|
|
::= { wtWebCount6ReportTable 1 }
|
|
|
|
WtWebCount6ReportEntry ::= SEQUENCE {
|
|
wtWebCount6ReportInputTrigger OCTET STRING,
|
|
wtWebCount6ReportSystemTrigger OCTET STRING,
|
|
wtWebCount6ReportMaxCounterValue OCTET STRING,
|
|
wtWebCount6ReportInterval OCTET STRING,
|
|
wtWebCount6ReportEnable OCTET STRING,
|
|
wtWebCount6ReportMailAddr OCTET STRING,
|
|
wtWebCount6ReportMailSubject OCTET STRING,
|
|
wtWebCount6ReportMailText OCTET STRING,
|
|
wtWebCount6ReportSnmpManagerIP OCTET STRING,
|
|
wtWebCount6ReportSnmpTrapText OCTET STRING,
|
|
wtWebCount6ReportUdpIpAddr OCTET STRING,
|
|
wtWebCount6ReportUdpPort INTEGER,
|
|
wtWebCount6ReportUdpText OCTET STRING,
|
|
wtWebCount6ReportTcpIpAddr OCTET STRING,
|
|
wtWebCount6ReportTcpPort INTEGER,
|
|
wtWebCount6ReportTcpText OCTET STRING,
|
|
wtWebCount6ReportSyslogIpAddr OCTET STRING,
|
|
wtWebCount6ReportSyslogPort INTEGER,
|
|
wtWebCount6ReportSyslogText OCTET STRING,
|
|
wtWebCount6ReportFtpDataPort OCTET STRING,
|
|
wtWebCount6ReportFtpFileName OCTET STRING,
|
|
wtWebCount6ReportFtpText OCTET STRING,
|
|
wtWebCount6ReportFtpOption OCTET STRING,
|
|
wtWebCount6ReportTimerCron OCTET STRING,
|
|
|
|
wtWebCount6ReportName OCTET STRING,
|
|
wtWebCount6ReportGlobalEnable OCTET STRING,
|
|
wtWebCount6ReportCounterClear OCTET STRING,
|
|
wtWebCount6ReportRateOfChange OCTET STRING,
|
|
wtWebCount6ReportRateOfChangeWindow OCTET STRING,
|
|
wtWebCount6ReportRateOfChange OCTET STRING,
|
|
wtWebCount6ReportRateOfChangeMode OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebCount6ReportInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-5: Mask for digital inputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-5: Level of digital inputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 9-12 contain the counter bit (1=ON, 0=OFF). Inputs masked with the counter bit trigger an Report
|
|
when the corresponding counter reaching the wtWebCount6ReportMaxCounterValue. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-5: Counter bits of digital inputs 0-5
|
|
Bit 6-7: unused."
|
|
|
|
::= { wtWebCount6ReportEntry 1 }
|
|
|
|
wtWebCount6ReportSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
|
|
Bit 7 : Timer OFF
|
|
Bit 6 : Time Window
|
|
Bit 5 : unused
|
|
Bit 4 : unused
|
|
Bit 3 : unused
|
|
Bit 2 : unused
|
|
Bit 1 : Timer
|
|
Bit 0 : unused"
|
|
::= { wtWebCount6ReportEntry 3 }
|
|
|
|
|
|
wtWebCount6ReportMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding Report is triggered. Input counters with
|
|
its mask bit unset in wtWebCount6ReportInputTrigger are not considered."
|
|
::= { wtWebCount6ReportEntry 4 }
|
|
|
|
wtWebCount6ReportInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for Report messages."
|
|
::= { wtWebCount6ReportEntry 5 }
|
|
|
|
wtWebCount6ReportEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded Report enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Output Switch Enable
|
|
Bit 1: Mail Enable
|
|
Bit 2: SNMP Trap enable
|
|
Bit 3: UDP enable
|
|
Bit 4: unused
|
|
Bit 5: TCP Client enable
|
|
Bit 6: Syslog Messages enable
|
|
Bit 7: FTP Client enable"
|
|
::= { wtWebCount6ReportEntry 6 }
|
|
|
|
wtWebCount6ReportMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the Report mail to."
|
|
::= { wtWebCount6ReportEntry 7 }
|
|
|
|
wtWebCount6ReportMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for Report mail."
|
|
::= { wtWebCount6ReportEntry 8 }
|
|
|
|
wtWebCount6ReportMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Report mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebCount6ReportEntry 9 }
|
|
|
|
wtWebCount6ReportSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebCount6ReportEntry 10 }
|
|
|
|
wtWebCount6ReportSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebCount6ReportEntry 11 }
|
|
|
|
wtWebCount6ReportUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebCount6ReportEntry 12 }
|
|
|
|
wtWebCount6ReportUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebCount6ReportEntry 13 }
|
|
|
|
wtWebCount6ReportUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebCount6ReportEntry 14 }
|
|
|
|
wtWebCount6ReportTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebCount6ReportEntry 15 }
|
|
|
|
wtWebCount6ReportTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebCount6ReportEntry 16 }
|
|
|
|
wtWebCount6ReportTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebCount6ReportEntry 17 }
|
|
|
|
wtWebCount6ReportSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebCount6ReportEntry 18 }
|
|
|
|
wtWebCount6ReportSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebCount6ReportEntry 19 }
|
|
|
|
wtWebCount6ReportSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebCount6ReportEntry 20 }
|
|
|
|
wtWebCount6ReportFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebCount6ReportEntry 21 }
|
|
|
|
wtWebCount6ReportFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebCount6ReportEntry 22 }
|
|
|
|
wtWebCount6ReportFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebCount6ReportEntry 23 }
|
|
|
|
wtWebCount6ReportFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebCount6ReportEntry 24 }
|
|
|
|
wtWebCount6ReportTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a report, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebCount6ReportEntry 25 }
|
|
|
|
wtWebCount6ReportName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Report."
|
|
::= { wtWebCount6ReportEntry 33 }
|
|
|
|
wtWebCount6ReportGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded Report activation:
|
|
Die OCTETS werden bitweise interpretiert.
|
|
Bit 0 entspricht dem LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Report enable"
|
|
::= { wtWebCount6ReportEntry 34 }
|
|
|
|
wtWebCount6ReportCounterClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Counter clear on Report send"
|
|
::= { wtWebCount6ReportEntry 35 }
|
|
|
|
wtWebCount6ReportRateOfChange OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value within a time slot. If an input counter value
|
|
exceeds this max. value, the corresponding Report is triggered. Input counters with
|
|
its mask bit unset in wtWebCount6ReportInputTrigger are not considered. A value of Zero
|
|
disable the tracing of rate of change."
|
|
::= { wtWebCount6ReportEntry 52 }
|
|
|
|
wtWebCount6ReportRateOfChangeWindow OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures the time slot of wtWebCount6ReportRateOfChange. Input counters with
|
|
its mask bit unset in wtWebCount6ReportInputTrigger are not considered. A value of Zero
|
|
disable the tracing of rate of change."
|
|
::= { wtWebCount6ReportEntry 53 }
|
|
|
|
wtWebCount6ReportRateOfChangeMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
Minimum mode: a report will be send if the count of pulses is lower than
|
|
the given pulse count in wtWebCount6ReportRateOfChange.
|
|
Maximum mode: a report will be send if the count of pulses is greater than
|
|
the pulse count given in wtWebCount6ReportRateOfChange.
|
|
The OCTETS are interpreted bit-by-bit, use only one bit at a time.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 2 : Maximum Mode
|
|
Bit 1 : Minimum Mode
|
|
Bit 0 : Rate of Change OFF"
|
|
::= { wtWebCount6ReportEntry 54 }
|
|
|
|
-- wtWebCount6Ports Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebCount6InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebCount6InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebCount6Ports 1 }
|
|
|
|
wtWebCount6InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebCount6InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebCount6InputNo }
|
|
::= { wtWebCount6InputPortTable 1 }
|
|
|
|
WtWebCount6InputPortEntry ::= SEQUENCE {
|
|
wtWebCount6PortInputName OCTET STRING,
|
|
wtWebCount6PortInputText OCTET STRING,
|
|
wtWebCount6PortInputMode OCTET STRING,
|
|
wtWebCount6PortInputFilter INTEGER,
|
|
wtWebCount6PortInputPulsePolarity OCTET STRING,
|
|
wtWebCount6PortInputBicountInactivTimeout INTEGER,
|
|
wtWebCount6PortInputCounterSet INTEGER,
|
|
wtWebCount6PortInputCounterScale OCTET STRING,
|
|
wtWebCount6PortInputCounterUnit OCTET STRING
|
|
}
|
|
|
|
wtWebCount6PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebCount6InputPortEntry 1 }
|
|
|
|
wtWebCount6PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebCount6InputPortEntry 2 }
|
|
|
|
wtWebCount6PortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : unused
|
|
Bit 1 : Change detection enable
|
|
Bit 0 : unused"
|
|
::= { wtWebCount6InputPortEntry 3 }
|
|
|
|
wtWebCount6PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebCount6InputPortEntry 4 }
|
|
|
|
wtWebCount6PortInputPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebCount6InputPortEntry 5 }
|
|
|
|
wtWebCount6PortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebCount6InputPortEntry 6 }
|
|
|
|
wtWebCount6PortInputCounterSet OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing to this variable presets the counter, while reading returns the actual value."
|
|
::= { wtWebCount6InputPortEntry 7 }
|
|
|
|
wtWebCount6PortInputCounterScale OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Conversion factor for this counter."
|
|
::= { wtWebCount6InputPortEntry 8 }
|
|
|
|
wtWebCount6PortInputCounterUnit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unit for this counter."
|
|
::= { wtWebCount6InputPortEntry 9 }
|
|
|
|
|
|
-- wtWebCount6Manufact Group
|
|
----------------------------
|
|
|
|
wtWebCount6MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebCount6Manufact 1 }
|
|
|
|
wtWebCount6MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebCount6Manufact 2 }
|
|
|
|
wtWebCount6MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebCount6Manufact 3 }
|
|
|
|
wtWebCount6MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebCount6Manufact 4 }
|
|
|
|
wtWebCount6MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebCount6Manufact 5 }
|
|
|
|
wtWebCount6MfOrderNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer part number."
|
|
::= { wtWebCount6Manufact 6 }
|
|
|
|
-- wtWebCount6Diag Group
|
|
----------------------------
|
|
|
|
wtWebCount6DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebCount6Diag 1 }
|
|
|
|
wtWebCount6DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebCount6Diag 2 }
|
|
|
|
wtWebCount6DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebCount6DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebCount6DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebCount6DiagErrorMessage."
|
|
::= { wtWebCount6Diag 3 }
|
|
|
|
wtWebCount6DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebCount6DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebCount6Diag 4 }
|
|
|
|
wtWebCount6DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebCount6Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Reporttriggerbedingungen zutreffen
|
|
|
|
wtWebCount6Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 1"
|
|
--#SUMMARY "Report 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebCount6Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 2"
|
|
--#SUMMARY "Report 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebCount6Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 3"
|
|
--#SUMMARY "Report 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebCount6Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 4"
|
|
--#SUMMARY "Report 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebCount6Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 5"
|
|
--#SUMMARY "Report 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebCount6Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 6"
|
|
--#SUMMARY "Report 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebCount6Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 7"
|
|
--#SUMMARY "Report 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebCount6Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 8"
|
|
--#SUMMARY "Report 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebCount6Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 9"
|
|
--#SUMMARY "Report 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebCount6Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 10"
|
|
--#SUMMARY "Report 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebCount6Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 11"
|
|
--#SUMMARY "Report 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebCount6Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES { wtWebCount6ReportSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Report 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Report 12"
|
|
--#SUMMARY "Report 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebCount6AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebCount6
|
|
VARIABLES {
|
|
wtWebCount6DiagErrorIndex,
|
|
wtWebCount6DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "WebCount Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebioEA6x6InOut Group
|
|
------------------------
|
|
|
|
wtWebioEA6x6Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebioEA6x6InOut 1 }
|
|
|
|
wtWebioEA6x6Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebioEA6x6InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA6x6InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA6x6InOut 3 }
|
|
|
|
wtWebioEA6x6InputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebioEA6x6InputNo }
|
|
::= { wtWebioEA6x6InputTable 1 }
|
|
|
|
WtWebioEA6x6InputEntry ::= SEQUENCE {
|
|
wtWebioEA6x6InputNo INTEGER,
|
|
wtWebioEA6x6InputCounter INTEGER,
|
|
wtWebioEA6x6InputCounterClear INTEGER,
|
|
wtWebioEA6x6InputState INTEGER
|
|
}
|
|
|
|
wtWebioEA6x6InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA6x6InputEntry 1 }
|
|
|
|
wtWebioEA6x6InputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA6x6InputEntry 2 }
|
|
|
|
wtWebioEA6x6InputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebioEA6x6InputEntry 3 }
|
|
|
|
wtWebioEA6x6InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA6x6InputEntry 4 }
|
|
|
|
wtWebioEA6x6InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, unused
|
|
OCTET 4, Bit 0-5: Digital outputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA6x6InOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA6x6OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA6x6InOut 5 }
|
|
|
|
wtWebioEA6x6OutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebioEA6x6OutputNo }
|
|
::= { wtWebioEA6x6OutputTable 1 }
|
|
|
|
WtWebioEA6x6OutputEntry ::= SEQUENCE {
|
|
wtWebioEA6x6OutputNo INTEGER,
|
|
wtWebioEA6x6OutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA6x6OutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebioEA6x6OutputEntry 1 }
|
|
|
|
wtWebioEA6x6OutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA6x6OutputEntry 2 }
|
|
|
|
wtWebioEA6x6OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, unused
|
|
OCTET 4, Bit 0-5: Digital outputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA6x6InOut 6 }
|
|
|
|
wtWebioEA6x6SetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4 : Bit 0-5: Mask for digital outputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8 : Bit 0-5: Level of digital outputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA6x6InOut 7 }
|
|
|
|
-- wtWebioEA6x6SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA6x6SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA6x6SessCntrl 1 }
|
|
|
|
wtWebioEA6x6SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA6x6SessCntrl 2 }
|
|
|
|
wtWebioEA6x6SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA6x6SessCntrl 3 }
|
|
|
|
wtWebioEA6x6SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA6x6SessCntrl 4 }
|
|
|
|
wtWebioEA6x6SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA6x6SessCntrl 5 }
|
|
|
|
-- wtWebioEA6x6Text Group
|
|
------------------------
|
|
|
|
wtWebioEA6x6DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA6x6Text 1 }
|
|
|
|
wtWebioEA6x6DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA6x6Text 2 }
|
|
|
|
wtWebioEA6x6DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA6x6Text 3 }
|
|
|
|
wtWebioEA6x6DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA6x6Text 4 }
|
|
|
|
-- wtWebioEA6x6TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA6x6TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA6x6TimeZone 1 }
|
|
|
|
wtWebioEA6x6TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA6x6TimeZone 2 }
|
|
|
|
wtWebioEA6x6TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA6x6TimeZone 3 }
|
|
|
|
wtWebioEA6x6StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA6x6TimeZone 4 }
|
|
|
|
wtWebioEA6x6StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA6x6TimeZone 5 }
|
|
|
|
wtWebioEA6x6StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA6x6TimeZone 6 }
|
|
|
|
wtWebioEA6x6StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA6x6StartMonth-January(1),
|
|
wtWebioEA6x6StartMonth-February(2),
|
|
wtWebioEA6x6StartMonth-March(3),
|
|
wtWebioEA6x6StartMonth-April(4),
|
|
wtWebioEA6x6StartMonth-May(5),
|
|
wtWebioEA6x6StartMonth-June(6),
|
|
wtWebioEA6x6StartMonth-July(7),
|
|
wtWebioEA6x6StartMonth-August(8),
|
|
wtWebioEA6x6StartMonth-September(9),
|
|
wtWebioEA6x6StartMonth-October(10),
|
|
wtWebioEA6x6StartMonth-November(11),
|
|
wtWebioEA6x6StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA6x6TimeZone 7 }
|
|
|
|
wtWebioEA6x6StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA6x6StartMode-first(1),
|
|
wtWebioEA6x6StartMode-second(2),
|
|
wtWebioEA6x6StartMode-third(3),
|
|
wtWebioEA6x6StartMode-fourth(4),
|
|
wtWebioEA6x6StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA6x6TimeZone 8 }
|
|
|
|
wtWebioEA6x6StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA6x6StartWday-Sunday(1),
|
|
wtWebioEA6x6StartWday-Monday(2),
|
|
wtWebioEA6x6StartWday-Tuesday(3),
|
|
wtWebioEA6x6StartWday-Thursday(4),
|
|
wtWebioEA6x6StartWday-Wednesday(5),
|
|
wtWebioEA6x6StartWday-Friday(6),
|
|
wtWebioEA6x6StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA6x6TimeZone 9 }
|
|
|
|
wtWebioEA6x6StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA6x6TimeZone 10 }
|
|
|
|
wtWebioEA6x6StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA6x6TimeZone 11 }
|
|
|
|
wtWebioEA6x6StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA6x6StopMonth-January(1),
|
|
wtWebioEA6x6StopMonth-February(2),
|
|
wtWebioEA6x6StopMonth-March(3),
|
|
wtWebioEA6x6StopMonth-April(4),
|
|
wtWebioEA6x6StopMonth-May(5),
|
|
wtWebioEA6x6StopMonth-June(6),
|
|
wtWebioEA6x6StopMonth-July(7),
|
|
wtWebioEA6x6StopMonth-August(8),
|
|
wtWebioEA6x6StopMonth-September(9),
|
|
wtWebioEA6x6StopMonth-October(10),
|
|
wtWebioEA6x6StopMonth-November(11),
|
|
wtWebioEA6x6StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA6x6TimeZone 12 }
|
|
|
|
wtWebioEA6x6StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA6x6StopMode-first(1),
|
|
wtWebioEA6x6StopMode-second(2),
|
|
wtWebioEA6x6StopMode-third(3),
|
|
wtWebioEA6x6StopMode-fourth(4),
|
|
wtWebioEA6x6StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA6x6TimeZone 13 }
|
|
|
|
wtWebioEA6x6StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA6x6StopWday-Sunday(1),
|
|
wtWebioEA6x6StopWday-Monday(2),
|
|
wtWebioEA6x6StopWday-Tuesday(3),
|
|
wtWebioEA6x6StopWday-Thursday(4),
|
|
wtWebioEA6x6StopWday-Wednesday(5),
|
|
wtWebioEA6x6StopWday-Friday(6),
|
|
wtWebioEA6x6StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA6x6TimeZone 14 }
|
|
|
|
wtWebioEA6x6StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA6x6TimeZone 15 }
|
|
|
|
wtWebioEA6x6StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA6x6TimeZone 16 }
|
|
|
|
-- wtWebioEA6x6TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA6x6TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA6x6TimeServer 1 }
|
|
|
|
wtWebioEA6x6TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA6x6TimeServer 2 }
|
|
|
|
wtWebioEA6x6TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA6x6TimeServer 3 }
|
|
|
|
wtWebioEA6x6TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA6x6TimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA6x6DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebioEA6x6ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA6x6DeviceClock 1 }
|
|
|
|
wtWebioEA6x6ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA6x6DeviceClock 2 }
|
|
|
|
wtWebioEA6x6ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA6x6DeviceClock 3 }
|
|
|
|
wtWebioEA6x6ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA6x6ClockMonth-January(1),
|
|
wtWebioEA6x6ClockMonth-February(2),
|
|
wtWebioEA6x6ClockMonth-March(3),
|
|
wtWebioEA6x6ClockMonth-April(4),
|
|
wtWebioEA6x6ClockMonth-May(5),
|
|
wtWebioEA6x6ClockMonth-June(6),
|
|
wtWebioEA6x6ClockMonth-July(7),
|
|
wtWebioEA6x6ClockMonth-August(8),
|
|
wtWebioEA6x6ClockMonth-September(9),
|
|
wtWebioEA6x6ClockMonth-October(10),
|
|
wtWebioEA6x6ClockMonth-November(11),
|
|
wtWebioEA6x6ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA6x6DeviceClock 4 }
|
|
|
|
wtWebioEA6x6ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA6x6DeviceClock 5 }
|
|
|
|
-- wtWebioEA6x6Network Group
|
|
------------------------
|
|
|
|
wtWebioEA6x6IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA6x6Network 1 }
|
|
|
|
wtWebioEA6x6SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA6x6Network 2 }
|
|
|
|
wtWebioEA6x6Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA6x6Network 3 }
|
|
|
|
wtWebioEA6x6DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA6x6Network 4 }
|
|
|
|
wtWebioEA6x6DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA6x6Network 5 }
|
|
|
|
wtWebioEA6x6AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA6x6Network 6 }
|
|
|
|
-- wtWebioEA6x6HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6Startup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA6x6HTTP 1 }
|
|
|
|
wtWebioEA6x6GetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA6x6HTTP 2 }
|
|
|
|
wtWebioEA6x6HttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-5: Digital inputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA6x6HTTP 3 }
|
|
|
|
wtWebioEA6x6HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA6x6HTTP 4 }
|
|
|
|
|
|
-- wtWebioEA6x6Mail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA6x6Mail 1 }
|
|
|
|
wtWebioEA6x6MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA6x6Mail 2 }
|
|
|
|
wtWebioEA6x6MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA6x6Mail 3 }
|
|
|
|
wtWebioEA6x6MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA6x6Mail 4 }
|
|
|
|
wtWebioEA6x6MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA6x6Mail 5 }
|
|
|
|
wtWebioEA6x6MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA6x6Mail 6 }
|
|
|
|
wtWebioEA6x6MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA6x6Mail 7 }
|
|
|
|
wtWebioEA6x6MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA6x6Mail 8 }
|
|
|
|
|
|
-- wtWebioEA6x6Snmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA6x6SNMP 1 }
|
|
|
|
wtWebioEA6x6SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA6x6SNMP 2 }
|
|
|
|
wtWebioEA6x6SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA6x6SNMP 3 }
|
|
|
|
wtWebioEA6x6SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA6x6SNMP 4 }
|
|
|
|
wtWebioEA6x6SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA6x6SNMP 5 }
|
|
|
|
-- wtWebioEA6x6Udp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA6x6UDP 1 }
|
|
|
|
wtWebioEA6x6UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA6x6UDP 2 }
|
|
|
|
wtWebioEA6x6UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA6x6UDP 3 }
|
|
|
|
-- wtWebioEA6x6Binary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6BinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA6x6Binary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA6x6BinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA6x6Binary 2 }
|
|
|
|
wtWebioEA6x6BinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA6x6BinaryModeNo }
|
|
::= { wtWebioEA6x6BinaryIfTable 1 }
|
|
|
|
WtWebioEA6x6BinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA6x6BinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA6x6BinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA6x6BinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6BinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA6x6Binary 3 }
|
|
|
|
wtWebioEA6x6BinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA6x6BinaryModeNo }
|
|
::= { wtWebioEA6x6BinaryTable 1 }
|
|
|
|
WtWebioEA6x6BinaryEntry ::= SEQUENCE {
|
|
wtWebioEA6x6BinaryOperationMode OCTET STRING,
|
|
wtWebioEA6x6BinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA6x6BinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA6x6BinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA6x6BinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA6x6BinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA6x6BinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA6x6BinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA6x6BinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA6x6BinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA6x6BinaryTcpClientInterval INTEGER,
|
|
wtWebioEA6x6BinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA6x6BinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA6x6BinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA6x6BinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA6x6BinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA6x6BinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA6x6BinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA6x6BinaryConnectedPort INTEGER,
|
|
wtWebioEA6x6BinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA6x6BinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA6x6BinaryTcpClientServerHttpPort INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA6x6BinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA6x6BinaryEntry 1 }
|
|
|
|
wtWebioEA6x6BinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA6x6BinaryEntry 2 }
|
|
|
|
wtWebioEA6x6BinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-5: Digital inputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA6x6BinaryEntry 3 }
|
|
|
|
wtWebioEA6x6BinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA6x6BinaryEntry 4 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA6x6BinaryEntry 5 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA6x6BinaryEntry 6 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA6x6BinaryEntry 7 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA6x6BinaryEntry 8 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA6x6BinaryEntry 9 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-5: Digital inputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA6x6BinaryEntry 10 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA6x6BinaryEntry 11 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA6x6BinaryEntry 12 }
|
|
|
|
wtWebioEA6x6BinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA6x6BinaryEntry 13 }
|
|
|
|
wtWebioEA6x6BinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA6x6BinaryEntry 14 }
|
|
|
|
wtWebioEA6x6BinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA6x6BinaryEntry 15 }
|
|
|
|
wtWebioEA6x6BinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-5: Digital inputs 0-5
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA6x6BinaryEntry 16 }
|
|
|
|
wtWebioEA6x6BinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA6x6BinaryEntry 17 }
|
|
|
|
wtWebioEA6x6BinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA6x6BinaryEntry 18 }
|
|
|
|
wtWebioEA6x6BinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA6x6BinaryEntry 19 }
|
|
|
|
wtWebioEA6x6BinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA6x6BinaryEntry 20 }
|
|
|
|
wtWebioEA6x6BinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA6x6BinaryEntry 21 }
|
|
|
|
wtWebioEA6x6BinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA6x6BinaryEntry 22 }
|
|
|
|
-- wtWebioEA6x6Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA6x6Syslog 1 }
|
|
|
|
wtWebioEA6x6SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA6x6Syslog 2 }
|
|
|
|
wtWebioEA6x6SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA6x6Syslog 3 }
|
|
|
|
wtWebioEA6x6SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA6x6Syslog 4 }
|
|
|
|
-- wtWebioEA6x6FTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA6x6FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA6x6FTP 1 }
|
|
|
|
wtWebioEA6x6FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA6x6FTP 2 }
|
|
|
|
wtWebioEA6x6FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA6x6FTP 3 }
|
|
|
|
wtWebioEA6x6FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA6x6FTP 4 }
|
|
|
|
wtWebioEA6x6FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA6x6FTP 5 }
|
|
|
|
wtWebioEA6x6FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA6x6FTP 6 }
|
|
|
|
wtWebioEA6x6FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA6x6FTP 7 }
|
|
|
|
-- wtWebioEA6x6OutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA6x6OutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA6x6OutputMode 1 }
|
|
|
|
wtWebioEA6x6OutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6OutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA6x6OutputNo }
|
|
::= { wtWebioEA6x6OutputModeTable 1 }
|
|
|
|
WtWebioEA6x6OutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA6x6OutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA6x6OutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA6x6OutputModeEntry 1 }
|
|
|
|
wtWebioEA6x6SafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA6x6OutputMode 2 }
|
|
|
|
|
|
-- wtWebioEA6x6Alarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA6x6AlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA6x6Alarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA6x6AlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA6x6Alarm 2 }
|
|
|
|
wtWebioEA6x6AlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA6x6AlarmNo }
|
|
::= { wtWebioEA6x6AlarmIfTable 1 }
|
|
|
|
WtWebioEA6x6AlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA6x6AlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA6x6AlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA6x6AlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA6x6AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA6x6Alarm 3 }
|
|
|
|
wtWebioEA6x6AlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA6x6AlarmNo }
|
|
::= { wtWebioEA6x6AlarmTable 1 }
|
|
|
|
WtWebioEA6x6AlarmEntry ::= SEQUENCE {
|
|
wtWebioEA6x6AlarmInputTrigger OCTET STRING,
|
|
wtWebioEA6x6AlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA6x6AlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA6x6AlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA6x6AlarmInterval OCTET STRING,
|
|
wtWebioEA6x6AlarmEnable OCTET STRING,
|
|
wtWebioEA6x6AlarmMailAddr OCTET STRING,
|
|
wtWebioEA6x6AlarmMailSubject OCTET STRING,
|
|
wtWebioEA6x6AlarmMailText OCTET STRING,
|
|
wtWebioEA6x6AlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA6x6AlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA6x6AlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA6x6AlarmUdpPort INTEGER,
|
|
wtWebioEA6x6AlarmUdpText OCTET STRING,
|
|
wtWebioEA6x6AlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA6x6AlarmTcpPort INTEGER,
|
|
wtWebioEA6x6AlarmTcpText OCTET STRING,
|
|
wtWebioEA6x6AlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA6x6AlarmSyslogPort INTEGER,
|
|
wtWebioEA6x6AlarmSyslogText OCTET STRING,
|
|
wtWebioEA6x6AlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA6x6AlarmFtpFileName OCTET STRING,
|
|
wtWebioEA6x6AlarmFtpText OCTET STRING,
|
|
wtWebioEA6x6AlarmFtpOption OCTET STRING,
|
|
wtWebioEA6x6AlarmTimerCron OCTET STRING,
|
|
|
|
wtWebioEA6x6AlarmMailReleaseSubject OCTET STRING,
|
|
wtWebioEA6x6AlarmMailReleaseText OCTET STRING,
|
|
wtWebioEA6x6AlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebioEA6x6AlarmUdpReleaseText OCTET STRING,
|
|
wtWebioEA6x6AlarmTcpReleaseText OCTET STRING,
|
|
wtWebioEA6x6AlarmSyslogReleaseText OCTET STRING,
|
|
wtWebioEA6x6AlarmFtpReleaseText OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA6x6AlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-5: Mask for digital inputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-5: Level of digital inputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-5: ANY bits of digital inputs 0-5
|
|
Bit 6-7: unused"
|
|
|
|
::= { wtWebioEA6x6AlarmEntry 1 }
|
|
|
|
wtWebioEA6x6AlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-5: Mask for digital outputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-5: Level of digital outputs 0-5
|
|
Bit 6-7: unused
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-5: ANY bits of digital outputs 0-5
|
|
Bit 6-7: unused"
|
|
|
|
::= { wtWebioEA6x6AlarmEntry 2 }
|
|
|
|
wtWebioEA6x6AlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebioEA6x6AlarmEntry 3 }
|
|
|
|
wtWebioEA6x6AlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA6x6AlarmInputTrigger are not considered."
|
|
::= { wtWebioEA6x6AlarmEntry 4 }
|
|
|
|
wtWebioEA6x6AlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA6x6AlarmEntry 5 }
|
|
|
|
wtWebioEA6x6AlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA6x6AlarmEntry 6 }
|
|
|
|
wtWebioEA6x6AlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA6x6AlarmEntry 7 }
|
|
|
|
wtWebioEA6x6AlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA6x6AlarmEntry 8 }
|
|
|
|
wtWebioEA6x6AlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA6x6AlarmEntry 9 }
|
|
|
|
wtWebioEA6x6AlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA6x6AlarmEntry 10 }
|
|
|
|
wtWebioEA6x6AlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA6x6AlarmEntry 11 }
|
|
|
|
wtWebioEA6x6AlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA6x6AlarmEntry 12 }
|
|
|
|
wtWebioEA6x6AlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA6x6AlarmEntry 13 }
|
|
|
|
wtWebioEA6x6AlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA6x6AlarmEntry 14 }
|
|
|
|
wtWebioEA6x6AlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA6x6AlarmEntry 15 }
|
|
|
|
wtWebioEA6x6AlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA6x6AlarmEntry 16 }
|
|
|
|
wtWebioEA6x6AlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA6x6AlarmEntry 17 }
|
|
|
|
wtWebioEA6x6AlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA6x6AlarmEntry 18 }
|
|
|
|
wtWebioEA6x6AlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA6x6AlarmEntry 19 }
|
|
|
|
wtWebioEA6x6AlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA6x6AlarmEntry 20 }
|
|
|
|
wtWebioEA6x6AlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA6x6AlarmEntry 21 }
|
|
|
|
wtWebioEA6x6AlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA6x6AlarmEntry 22 }
|
|
|
|
wtWebioEA6x6AlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA6x6AlarmEntry 23 }
|
|
|
|
wtWebioEA6x6AlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA6x6AlarmEntry 24 }
|
|
|
|
wtWebioEA6x6AlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA6x6AlarmEntry 25 }
|
|
|
|
|
|
wtWebioEA6x6AlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA6x6AlarmEntry 26 }
|
|
|
|
wtWebioEA6x6AlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA6x6AlarmEntry 27 }
|
|
|
|
wtWebioEA6x6AlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA6x6AlarmEntry 28 }
|
|
|
|
wtWebioEA6x6AlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA6x6AlarmEntry 29 }
|
|
|
|
wtWebioEA6x6AlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA6x6AlarmEntry 30 }
|
|
|
|
wtWebioEA6x6AlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA6x6AlarmEntry 31 }
|
|
|
|
wtWebioEA6x6AlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA6x6AlarmEntry 32 }
|
|
|
|
-- wtWebioEA6x6Ports Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA6x6InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA6x6Ports 1 }
|
|
|
|
wtWebioEA6x6InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA6x6InputNo }
|
|
::= { wtWebioEA6x6InputPortTable 1 }
|
|
|
|
WtWebioEA6x6InputPortEntry ::= SEQUENCE {
|
|
wtWebioEA6x6PortInputName OCTET STRING,
|
|
wtWebioEA6x6PortInputText OCTET STRING,
|
|
wtWebioEA6x6PortInputMode OCTET STRING,
|
|
wtWebioEA6x6PortInputFilter INTEGER,
|
|
wtWebioEA6x6PortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebioEA6x6PortInputBicountInactivTimeout INTEGER
|
|
}
|
|
|
|
wtWebioEA6x6PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA6x6InputPortEntry 1 }
|
|
|
|
wtWebioEA6x6PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA6x6InputPortEntry 2 }
|
|
|
|
wtWebioEA6x6PortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-3:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 3-7: unused
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable
|
|
|
|
Selection for inputs 4-5:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Counter clear on read
|
|
Bit 0 : Change detection enable (default)"
|
|
::= { wtWebioEA6x6InputPortEntry 3 }
|
|
|
|
wtWebioEA6x6PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA6x6InputPortEntry 4 }
|
|
|
|
wtWebioEA6x6PortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA6x6InputPortEntry 5 }
|
|
|
|
wtWebioEA6x6PortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebioEA6x6InputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA6x6OutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA6x6OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA6x6Ports 2 }
|
|
|
|
wtWebioEA6x6OutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA6x6OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA6x6OutputNo }
|
|
::= { wtWebioEA6x6OutputPortTable 1 }
|
|
|
|
WtWebioEA6x6OutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA6x6PortOutputName OCTET STRING,
|
|
wtWebioEA6x6PortOutputText OCTET STRING,
|
|
wtWebioEA6x6PortOutputGroupMode OCTET STRING,
|
|
wtWebioEA6x6PortOutputSafetyState OCTET STRING,
|
|
wtWebioEA6x6PortLogicInputMask OCTET STRING,
|
|
wtWebioEA6x6PortLogicInputInverter OCTET STRING,
|
|
wtWebioEA6x6PortLogicFunction OCTET STRING,
|
|
wtWebioEA6x6PortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA6x6PortPulseDuration INTEGER,
|
|
wtWebioEA6x6PortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA6x6PortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA6x6OutputPortEntry 1 }
|
|
|
|
wtWebioEA6x6PortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA6x6OutputPortEntry 2 }
|
|
|
|
wtWebioEA6x6PortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one output bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for outputs 0-3:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 0,1,2,3 disconnected (default)
|
|
Bit 1 : outputs 0+1, 2+3 connected
|
|
Bit 2 : outputs 0+1+2+3 connected
|
|
Bit 3-7 : unused
|
|
Selection for outputs 4-7:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : outputs 4, 5 disconnected (default)
|
|
Bit 1 : outputs 4+5 connected
|
|
Bit 2-7 : unused
|
|
Selection for outputs 8-11:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: unused"
|
|
::= { wtWebioEA6x6OutputPortEntry 3 }
|
|
|
|
wtWebioEA6x6PortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebioEA6x6OutputPortEntry 4 }
|
|
|
|
wtWebioEA6x6PortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA6x6PortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA6x6PortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA6x6PortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA6x6PortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0-5 : inputs 0-5
|
|
Bit 6-7 : unused"
|
|
::= { wtWebioEA6x6OutputPortEntry 5 }
|
|
|
|
wtWebioEA6x6PortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0-5 : inputs 0-5
|
|
Bit 6-7 : unused"
|
|
::= { wtWebioEA6x6OutputPortEntry 6 }
|
|
|
|
wtWebioEA6x6PortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA6x6OutputPortEntry 7 }
|
|
|
|
wtWebioEA6x6PortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA6x6OutputPortEntry 8 }
|
|
|
|
wtWebioEA6x6PortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA6x6OutputPortEntry 9 }
|
|
|
|
wtWebioEA6x6PortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA6x6PortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA6x6OutputPortEntry 10 }
|
|
|
|
-- wtWebioEA6x6Manufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA6x6MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA6x6Manufact 1 }
|
|
|
|
wtWebioEA6x6MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA6x6Manufact 2 }
|
|
|
|
wtWebioEA6x6MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA6x6Manufact 3 }
|
|
|
|
wtWebioEA6x6MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA6x6Manufact 4 }
|
|
|
|
wtWebioEA6x6MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA6x6Manufact 5 }
|
|
|
|
-- wtWebioEA6x6Diag Group
|
|
----------------------------
|
|
|
|
wtWebioEA6x6DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA6x6Diag 1 }
|
|
|
|
wtWebioEA6x6DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA6x6Diag 2 }
|
|
|
|
wtWebioEA6x6DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA6x6DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA6x6DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA6x6DiagErrorMessage."
|
|
::= { wtWebioEA6x6Diag 3 }
|
|
|
|
wtWebioEA6x6DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA6x6DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA6x6Diag 4 }
|
|
|
|
wtWebioEA6x6DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA6x6Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA6x6Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebioEA6x6Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebioEA6x6Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebioEA6x6Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebioEA6x6Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebioEA6x6Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebioEA6x6Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebioEA6x6Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebioEA6x6Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebioEA6x6Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebioEA6x6Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebioEA6x6Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebioEA6x6Alert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA6x6Alert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA6x6Alert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA6x6Alert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA6x6Alert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA6x6Alert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA6x6Alert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA6x6Alert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA6x6Alert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA6x6Alert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA6x6Alert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA6x6Alert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES { wtWebioEA6x6AlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA6x6AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA6x6
|
|
VARIABLES {
|
|
wtWebioEA6x6DiagErrorIndex,
|
|
wtWebioEA6x6DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebioEA2x2ERPInOut Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2ERPInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebioEA2x2ERPInOut 1 }
|
|
|
|
wtWebioEA2x2ERPOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebioEA2x2ERPInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA2x2ERPInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA2x2ERPInOut 3 }
|
|
|
|
wtWebioEA2x2ERPInputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebioEA2x2ERPInputNo }
|
|
::= { wtWebioEA2x2ERPInputTable 1 }
|
|
|
|
WtWebioEA2x2ERPInputEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPInputNo INTEGER,
|
|
wtWebioEA2x2ERPInputCounter INTEGER,
|
|
wtWebioEA2x2ERPInputCounterClear INTEGER,
|
|
wtWebioEA2x2ERPInputState INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERPInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA2x2ERPInputEntry 1 }
|
|
|
|
wtWebioEA2x2ERPInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA2x2ERPInputEntry 2 }
|
|
|
|
wtWebioEA2x2ERPInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebioEA2x2ERPInputEntry 3 }
|
|
|
|
wtWebioEA2x2ERPInputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA2x2ERPInputEntry 4 }
|
|
|
|
wtWebioEA2x2ERPInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtWebioEA2x2ERPInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA2x2ERPOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA2x2ERPInOut 5 }
|
|
|
|
wtWebioEA2x2ERPOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebioEA2x2ERPOutputNo }
|
|
::= { wtWebioEA2x2ERPOutputTable 1 }
|
|
|
|
WtWebioEA2x2ERPOutputEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPOutputNo INTEGER,
|
|
wtWebioEA2x2ERPOutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2ERPOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebioEA2x2ERPOutputEntry 1 }
|
|
|
|
wtWebioEA2x2ERPOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA2x2ERPOutputEntry 2 }
|
|
|
|
|
|
wtWebioEA2x2ERPOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtWebioEA2x2ERPInOut 6 }
|
|
|
|
wtWebioEA2x2ERPSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1"
|
|
::= { wtWebioEA2x2ERPInOut 7 }
|
|
|
|
-- wtWebioEA2x2ERPSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA2x2ERPSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA2x2ERPSessCntrl 1 }
|
|
|
|
wtWebioEA2x2ERPSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA2x2ERPSessCntrl 2 }
|
|
|
|
wtWebioEA2x2ERPSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA2x2ERPSessCntrl 3 }
|
|
|
|
wtWebioEA2x2ERPSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA2x2ERPSessCntrl 4 }
|
|
|
|
wtWebioEA2x2ERPSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA2x2ERPSessCntrl 5 }
|
|
|
|
-- wtWebioEA2x2ERPText Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2ERPDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2ERPText 1 }
|
|
|
|
wtWebioEA2x2ERPDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2ERPText 2 }
|
|
|
|
wtWebioEA2x2ERPDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2ERPText 3 }
|
|
|
|
wtWebioEA2x2ERPDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2ERPText 4 }
|
|
|
|
-- wtWebioEA2x2ERPTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERPTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA2x2ERPTimeZone 1 }
|
|
|
|
wtWebioEA2x2ERPTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA2x2ERPTimeZone 2 }
|
|
|
|
wtWebioEA2x2ERPTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA2x2ERPTimeZone 3 }
|
|
|
|
wtWebioEA2x2ERPStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA2x2ERPTimeZone 4 }
|
|
|
|
wtWebioEA2x2ERPStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA2x2ERPTimeZone 5 }
|
|
|
|
wtWebioEA2x2ERPStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA2x2ERPTimeZone 6 }
|
|
|
|
wtWebioEA2x2ERPStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERPStartMonth-January(1),
|
|
wtWebioEA2x2ERPStartMonth-February(2),
|
|
wtWebioEA2x2ERPStartMonth-March(3),
|
|
wtWebioEA2x2ERPStartMonth-April(4),
|
|
wtWebioEA2x2ERPStartMonth-May(5),
|
|
wtWebioEA2x2ERPStartMonth-June(6),
|
|
wtWebioEA2x2ERPStartMonth-July(7),
|
|
wtWebioEA2x2ERPStartMonth-August(8),
|
|
wtWebioEA2x2ERPStartMonth-September(9),
|
|
wtWebioEA2x2ERPStartMonth-October(10),
|
|
wtWebioEA2x2ERPStartMonth-November(11),
|
|
wtWebioEA2x2ERPStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA2x2ERPTimeZone 7 }
|
|
|
|
wtWebioEA2x2ERPStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERPStartMode-first(1),
|
|
wtWebioEA2x2ERPStartMode-second(2),
|
|
wtWebioEA2x2ERPStartMode-third(3),
|
|
wtWebioEA2x2ERPStartMode-fourth(4),
|
|
wtWebioEA2x2ERPStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA2x2ERPTimeZone 8 }
|
|
|
|
wtWebioEA2x2ERPStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERPStartWday-Sunday(1),
|
|
wtWebioEA2x2ERPStartWday-Monday(2),
|
|
wtWebioEA2x2ERPStartWday-Tuesday(3),
|
|
wtWebioEA2x2ERPStartWday-Thursday(4),
|
|
wtWebioEA2x2ERPStartWday-Wednesday(5),
|
|
wtWebioEA2x2ERPStartWday-Friday(6),
|
|
wtWebioEA2x2ERPStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA2x2ERPTimeZone 9 }
|
|
|
|
wtWebioEA2x2ERPStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2ERPTimeZone 10 }
|
|
|
|
wtWebioEA2x2ERPStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2ERPTimeZone 11 }
|
|
|
|
wtWebioEA2x2ERPStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERPStopMonth-January(1),
|
|
wtWebioEA2x2ERPStopMonth-February(2),
|
|
wtWebioEA2x2ERPStopMonth-March(3),
|
|
wtWebioEA2x2ERPStopMonth-April(4),
|
|
wtWebioEA2x2ERPStopMonth-May(5),
|
|
wtWebioEA2x2ERPStopMonth-June(6),
|
|
wtWebioEA2x2ERPStopMonth-July(7),
|
|
wtWebioEA2x2ERPStopMonth-August(8),
|
|
wtWebioEA2x2ERPStopMonth-September(9),
|
|
wtWebioEA2x2ERPStopMonth-October(10),
|
|
wtWebioEA2x2ERPStopMonth-November(11),
|
|
wtWebioEA2x2ERPStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2ERPTimeZone 12 }
|
|
|
|
wtWebioEA2x2ERPStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERPStopMode-first(1),
|
|
wtWebioEA2x2ERPStopMode-second(2),
|
|
wtWebioEA2x2ERPStopMode-third(3),
|
|
wtWebioEA2x2ERPStopMode-fourth(4),
|
|
wtWebioEA2x2ERPStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2ERPTimeZone 13 }
|
|
|
|
wtWebioEA2x2ERPStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERPStopWday-Sunday(1),
|
|
wtWebioEA2x2ERPStopWday-Monday(2),
|
|
wtWebioEA2x2ERPStopWday-Tuesday(3),
|
|
wtWebioEA2x2ERPStopWday-Thursday(4),
|
|
wtWebioEA2x2ERPStopWday-Wednesday(5),
|
|
wtWebioEA2x2ERPStopWday-Friday(6),
|
|
wtWebioEA2x2ERPStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2ERPTimeZone 14 }
|
|
|
|
wtWebioEA2x2ERPStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2ERPTimeZone 15 }
|
|
|
|
wtWebioEA2x2ERPStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2ERPTimeZone 16 }
|
|
|
|
-- wtWebioEA2x2ERPTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERPTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA2x2ERPTimeServer 1 }
|
|
|
|
wtWebioEA2x2ERPTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA2x2ERPTimeServer 2 }
|
|
|
|
wtWebioEA2x2ERPTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA2x2ERPTimeServer 3 }
|
|
|
|
wtWebioEA2x2ERPTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA2x2ERPTimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA2x2ERPDeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERPClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERPDeviceClock 1 }
|
|
|
|
wtWebioEA2x2ERPClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERPDeviceClock 2 }
|
|
|
|
wtWebioEA2x2ERPClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERPDeviceClock 3 }
|
|
|
|
wtWebioEA2x2ERPClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERPClockMonth-January(1),
|
|
wtWebioEA2x2ERPClockMonth-February(2),
|
|
wtWebioEA2x2ERPClockMonth-March(3),
|
|
wtWebioEA2x2ERPClockMonth-April(4),
|
|
wtWebioEA2x2ERPClockMonth-May(5),
|
|
wtWebioEA2x2ERPClockMonth-June(6),
|
|
wtWebioEA2x2ERPClockMonth-July(7),
|
|
wtWebioEA2x2ERPClockMonth-August(8),
|
|
wtWebioEA2x2ERPClockMonth-September(9),
|
|
wtWebioEA2x2ERPClockMonth-October(10),
|
|
wtWebioEA2x2ERPClockMonth-November(11),
|
|
wtWebioEA2x2ERPClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERPDeviceClock 4 }
|
|
|
|
wtWebioEA2x2ERPClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERPDeviceClock 5 }
|
|
|
|
-- wtWebioEA2x2ERPNetwork Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2ERPIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA2x2ERPNetwork 1 }
|
|
|
|
wtWebioEA2x2ERPSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA2x2ERPNetwork 2 }
|
|
|
|
wtWebioEA2x2ERPGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA2x2ERPNetwork 3 }
|
|
|
|
wtWebioEA2x2ERPDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA2x2ERPNetwork 4 }
|
|
|
|
wtWebioEA2x2ERPDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA2x2ERPNetwork 5 }
|
|
|
|
wtWebioEA2x2ERPAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA2x2ERPNetwork 6 }
|
|
|
|
-- wtWebioEA2x2ERPHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA2x2ERPHTTP 1 }
|
|
|
|
wtWebioEA2x2ERPGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA2x2ERPHTTP 2 }
|
|
|
|
wtWebioEA2x2ERPHttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2ERPHTTP 3 }
|
|
|
|
wtWebioEA2x2ERPHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA2x2ERPHTTP 4 }
|
|
|
|
|
|
-- wtWebioEA2x2ERPMail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA2x2ERPMail 1 }
|
|
|
|
wtWebioEA2x2ERPMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA2x2ERPMail 2 }
|
|
|
|
wtWebioEA2x2ERPMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA2x2ERPMail 3 }
|
|
|
|
wtWebioEA2x2ERPMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA2x2ERPMail 4 }
|
|
|
|
wtWebioEA2x2ERPMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA2x2ERPMail 5 }
|
|
|
|
wtWebioEA2x2ERPMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA2x2ERPMail 6 }
|
|
|
|
wtWebioEA2x2ERPMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA2x2ERPMail 7 }
|
|
|
|
wtWebioEA2x2ERPMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA2x2ERPMail 8 }
|
|
|
|
|
|
-- wtWebioEA2x2ERPSnmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA2x2ERPSNMP 1 }
|
|
|
|
wtWebioEA2x2ERPSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA2x2ERPSNMP 2 }
|
|
|
|
wtWebioEA2x2ERPSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA2x2ERPSNMP 3 }
|
|
|
|
wtWebioEA2x2ERPSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA2x2ERPSNMP 4 }
|
|
|
|
wtWebioEA2x2ERPSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA2x2ERPSNMP 5 }
|
|
|
|
-- wtWebioEA2x2ERPUDP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA2x2ERPUDP 1 }
|
|
|
|
wtWebioEA2x2ERPUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA2x2ERPUDP 2 }
|
|
|
|
wtWebioEA2x2ERPUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA2x2ERPUDP 3 }
|
|
|
|
-- wtWebioEA2x2ERPBinary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPBinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA2x2ERPBinary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA2x2ERPBinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA2x2ERPBinary 2 }
|
|
|
|
wtWebioEA2x2ERPBinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA2x2ERPBinaryModeNo }
|
|
::= { wtWebioEA2x2ERPBinaryIfTable 1 }
|
|
|
|
WtWebioEA2x2ERPBinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPBinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2ERPBinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA2x2ERPBinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPBinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA2x2ERPBinary 3 }
|
|
|
|
wtWebioEA2x2ERPBinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA2x2ERPBinaryModeNo }
|
|
::= { wtWebioEA2x2ERPBinaryTable 1 }
|
|
|
|
WtWebioEA2x2ERPBinaryEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPBinaryOperationMode OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA2x2ERPBinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA2x2ERPBinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA2x2ERPBinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA2x2ERPBinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryTcpClientInterval INTEGER,
|
|
wtWebioEA2x2ERPBinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA2x2ERPBinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA2x2ERPBinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA2x2ERPBinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA2x2ERPBinaryConnectedPort INTEGER,
|
|
wtWebioEA2x2ERPBinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA2x2ERPBinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA2x2ERPBinaryTcpClientServerHttpPort INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERPBinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA2x2ERPBinaryEntry 1 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 2 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2ERPBinaryEntry 3 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2ERPBinaryEntry 4 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 5 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 6 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 7 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 8 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 9 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2ERPBinaryEntry 10 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 11 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2ERPBinaryEntry 12 }
|
|
|
|
wtWebioEA2x2ERPBinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 13 }
|
|
|
|
wtWebioEA2x2ERPBinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 14 }
|
|
|
|
wtWebioEA2x2ERPBinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 15 }
|
|
|
|
wtWebioEA2x2ERPBinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2ERPBinaryEntry 16 }
|
|
|
|
wtWebioEA2x2ERPBinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 17 }
|
|
|
|
wtWebioEA2x2ERPBinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2ERPBinaryEntry 18 }
|
|
|
|
wtWebioEA2x2ERPBinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 19 }
|
|
|
|
wtWebioEA2x2ERPBinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 20 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 21 }
|
|
|
|
wtWebioEA2x2ERPBinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA2x2ERPBinaryEntry 22 }
|
|
|
|
-- wtWebioEA2x2ERPSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA2x2ERPSyslog 1 }
|
|
|
|
wtWebioEA2x2ERPSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA2x2ERPSyslog 2 }
|
|
|
|
wtWebioEA2x2ERPSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA2x2ERPSyslog 3 }
|
|
|
|
wtWebioEA2x2ERPSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA2x2ERPSyslog 4 }
|
|
|
|
-- wtWebioEA2x2ERPFTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA2x2ERPFTP 1 }
|
|
|
|
wtWebioEA2x2ERPFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA2x2ERPFTP 2 }
|
|
|
|
wtWebioEA2x2ERPFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA2x2ERPFTP 3 }
|
|
|
|
wtWebioEA2x2ERPFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA2x2ERPFTP 4 }
|
|
|
|
wtWebioEA2x2ERPFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA2x2ERPFTP 5 }
|
|
|
|
wtWebioEA2x2ERPFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA2x2ERPFTP 6 }
|
|
|
|
wtWebioEA2x2ERPFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA2x2ERPFTP 7 }
|
|
|
|
-- wtWebioEA2x2ERPWayBack Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERPWayBackEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable WayBack:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : WayBack enable"
|
|
::= { wtWebioEA2x2ERPWayBack 1 }
|
|
|
|
wtWebioEA2x2ERPWayBackServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA2x2ERPWayBack 2 }
|
|
|
|
wtWebioEA2x2ERPWayBackFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP Loggin: Password of the user."
|
|
::= { wtWebioEA2x2ERPWayBack 3 }
|
|
|
|
wtWebioEA2x2ERPWayBackFTPResponse OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP response: return message after login."
|
|
::= { wtWebioEA2x2ERPWayBack 4 }
|
|
|
|
wtWebioEA2x2ERPWayBackFTPTimeOut OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP Timeout: a request must be finished within this periode of time."
|
|
::= { wtWebioEA2x2ERPWayBack 5 }
|
|
|
|
-- wtWebioEA2x2ERPOutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA2x2ERPOutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA2x2ERPOutputMode 1 }
|
|
|
|
wtWebioEA2x2ERPOutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA2x2ERPOutputNo }
|
|
::= { wtWebioEA2x2ERPOutputModeTable 1 }
|
|
|
|
WtWebioEA2x2ERPOutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPOutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA2x2ERPOutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA2x2ERPOutputModeEntry 1 }
|
|
|
|
wtWebioEA2x2ERPSafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA2x2ERPOutputMode 2 }
|
|
|
|
wtWebioEA2x2ERPLoadControlEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the function of automatic load control can be enabled. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Load Control enable"
|
|
::= { wtWebioEA2x2ERPOutputMode 3 }
|
|
|
|
-- wtWebioEA2x2ERPAlarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERPAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA2x2ERPAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA2x2ERPAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA2x2ERPAlarm 2 }
|
|
|
|
wtWebioEA2x2ERPAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA2x2ERPAlarmNo }
|
|
::= { wtWebioEA2x2ERPAlarmIfTable 1 }
|
|
|
|
WtWebioEA2x2ERPAlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2ERPAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA2x2ERPAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA2x2ERPAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA2x2ERPAlarm 3 }
|
|
|
|
wtWebioEA2x2ERPAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA2x2ERPAlarmNo }
|
|
::= { wtWebioEA2x2ERPAlarmTable 1 }
|
|
|
|
WtWebioEA2x2ERPAlarmEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPAlarmInputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmInterval OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmEnable OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmMailAddr OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmMailSubject OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmMailText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmUdpPort INTEGER,
|
|
wtWebioEA2x2ERPAlarmUdpText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmTcpPort INTEGER,
|
|
wtWebioEA2x2ERPAlarmTcpText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmSyslogPort INTEGER,
|
|
wtWebioEA2x2ERPAlarmSyslogText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmFtpFileName OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmFtpText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmFtpOption OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmTimerCron OCTET STRING,
|
|
|
|
wtWebioEA2x2ERPAlarmMailReleaseSubject OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmMailReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmUdpReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmTcpReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmSyslogReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERPAlarmFtpReleaseText OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERPAlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital inputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital inputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1"
|
|
|
|
::= { wtWebioEA2x2ERPAlarmEntry 1 }
|
|
|
|
wtWebioEA2x2ERPAlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1"
|
|
|
|
::= { wtWebioEA2x2ERPAlarmEntry 2 }
|
|
|
|
wtWebioEA2x2ERPAlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebioEA2x2ERPAlarmEntry 3 }
|
|
|
|
wtWebioEA2x2ERPAlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA2x2ERPAlarmInputTrigger are not considered."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 4 }
|
|
|
|
wtWebioEA2x2ERPAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 5 }
|
|
|
|
wtWebioEA2x2ERPAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA2x2ERPAlarmEntry 6 }
|
|
|
|
wtWebioEA2x2ERPAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 7 }
|
|
|
|
wtWebioEA2x2ERPAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 8 }
|
|
|
|
wtWebioEA2x2ERPAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA2x2ERPAlarmEntry 9 }
|
|
|
|
wtWebioEA2x2ERPAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 10 }
|
|
|
|
wtWebioEA2x2ERPAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 11 }
|
|
|
|
wtWebioEA2x2ERPAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 12 }
|
|
|
|
wtWebioEA2x2ERPAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 13 }
|
|
|
|
wtWebioEA2x2ERPAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 14 }
|
|
|
|
wtWebioEA2x2ERPAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 15 }
|
|
|
|
wtWebioEA2x2ERPAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 16 }
|
|
|
|
wtWebioEA2x2ERPAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 17 }
|
|
|
|
wtWebioEA2x2ERPAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 18 }
|
|
|
|
wtWebioEA2x2ERPAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 19 }
|
|
|
|
wtWebioEA2x2ERPAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 20 }
|
|
|
|
wtWebioEA2x2ERPAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 21 }
|
|
|
|
wtWebioEA2x2ERPAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 22 }
|
|
|
|
wtWebioEA2x2ERPAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 23 }
|
|
|
|
wtWebioEA2x2ERPAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA2x2ERPAlarmEntry 24 }
|
|
|
|
wtWebioEA2x2ERPAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 25 }
|
|
|
|
wtWebioEA2x2ERPAlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 26 }
|
|
|
|
wtWebioEA2x2ERPAlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA2x2ERPAlarmEntry 27 }
|
|
|
|
wtWebioEA2x2ERPAlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 28 }
|
|
|
|
wtWebioEA2x2ERPAlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 29 }
|
|
|
|
wtWebioEA2x2ERPAlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 30 }
|
|
|
|
wtWebioEA2x2ERPAlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 31 }
|
|
|
|
wtWebioEA2x2ERPAlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA2x2ERPAlarmEntry 32 }
|
|
|
|
-- wtWebioEA2x2ERPLoadControl
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERPLoadControlView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of automatic load control can be read. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0-1: outputs 0-1."
|
|
::= { wtWebioEA2x2ERPAlarm 4 }
|
|
|
|
wtWebioEA2x2ERPLCShutDownView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of the automatic load control shut down can be read. All outputs remain switched of,
|
|
until a zero is written into this variable. But previously all loads should be inspected.
|
|
High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason.
|
|
If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair.
|
|
All controlled output could be identified reading the variable wtWebioEA2x2ERPLoadControlEnable.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4: Bit 0-1: outputs 0-1."
|
|
::= { wtWebioEA2x2ERPAlarm 5 }
|
|
|
|
-- wtWebioEA2x2ERPPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA2x2ERPInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA2x2ERPPorts 1 }
|
|
|
|
wtWebioEA2x2ERPInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA2x2ERPInputNo }
|
|
::= { wtWebioEA2x2ERPInputPortTable 1 }
|
|
|
|
WtWebioEA2x2ERPInputPortEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPPortInputName OCTET STRING,
|
|
wtWebioEA2x2ERPPortInputText OCTET STRING,
|
|
wtWebioEA2x2ERPPortInputMode OCTET STRING,
|
|
wtWebioEA2x2ERPPortInputFilter INTEGER,
|
|
wtWebioEA2x2ERPPortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebioEA2x2ERPPortInputBicountInactivTimeout INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERPPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA2x2ERPInputPortEntry 1 }
|
|
|
|
wtWebioEA2x2ERPPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA2x2ERPInputPortEntry 2 }
|
|
|
|
wtWebioEA2x2ERPPortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable"
|
|
::= { wtWebioEA2x2ERPInputPortEntry 3 }
|
|
|
|
wtWebioEA2x2ERPPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA2x2ERPInputPortEntry 4 }
|
|
|
|
wtWebioEA2x2ERPPortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2ERPInputPortEntry 5 }
|
|
|
|
wtWebioEA2x2ERPPortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebioEA2x2ERPInputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA2x2ERPOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERPOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA2x2ERPPorts 2 }
|
|
|
|
wtWebioEA2x2ERPOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERPOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA2x2ERPOutputNo }
|
|
::= { wtWebioEA2x2ERPOutputPortTable 1 }
|
|
|
|
WtWebioEA2x2ERPOutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERPPortOutputName OCTET STRING,
|
|
wtWebioEA2x2ERPPortOutputText OCTET STRING,
|
|
wtWebioEA2x2ERPPortOutputGroupMode OCTET STRING,
|
|
wtWebioEA2x2ERPPortOutputSafetyState OCTET STRING,
|
|
wtWebioEA2x2ERPPortLogicInputMask OCTET STRING,
|
|
wtWebioEA2x2ERPPortLogicInputInverter OCTET STRING,
|
|
wtWebioEA2x2ERPPortLogicFunction OCTET STRING,
|
|
wtWebioEA2x2ERPPortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA2x2ERPPortPulseDuration INTEGER,
|
|
wtWebioEA2x2ERPPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERPPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 1 }
|
|
|
|
wtWebioEA2x2ERPPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 2 }
|
|
|
|
wtWebioEA2x2ERPPortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one ouput bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for ouputs 0-1:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : ouputs 0,1 disconnected (default)
|
|
Bit 1 : ouputs 0+1 connected"
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 3 }
|
|
|
|
wtWebioEA2x2ERPPortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 4 }
|
|
|
|
wtWebioEA2x2ERPPortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA2x2ERPPortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA2x2ERPPortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA2x2ERPPortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA2x2ERPPortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 5 }
|
|
|
|
wtWebioEA2x2ERPPortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 6 }
|
|
|
|
wtWebioEA2x2ERPPortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 7 }
|
|
|
|
wtWebioEA2x2ERPPortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 8 }
|
|
|
|
wtWebioEA2x2ERPPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 9 }
|
|
|
|
wtWebioEA2x2ERPPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA2x2ERPPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2ERPOutputPortEntry 10 }
|
|
|
|
-- wtWebioEA2x2ERPManufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERPMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA2x2ERPManufact 1 }
|
|
|
|
wtWebioEA2x2ERPMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA2x2ERPManufact 2 }
|
|
|
|
wtWebioEA2x2ERPMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA2x2ERPManufact 3 }
|
|
|
|
wtWebioEA2x2ERPMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA2x2ERPManufact 4 }
|
|
|
|
wtWebioEA2x2ERPMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA2x2ERPManufact 5 }
|
|
|
|
-- wtWebioEA2x2ERPDiag Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERPDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA2x2ERPDiag 1 }
|
|
|
|
wtWebioEA2x2ERPDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA2x2ERPDiag 2 }
|
|
|
|
wtWebioEA2x2ERPDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA2x2ERPDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA2x2ERPDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA2x2ERPDiagErrorMessage."
|
|
::= { wtWebioEA2x2ERPDiag 3 }
|
|
|
|
wtWebioEA2x2ERPDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA2x2ERPDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA2x2ERPDiag 4 }
|
|
|
|
wtWebioEA2x2ERPDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA2x2ERPDiag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA2x2ERPAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebioEA2x2ERPAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebioEA2x2ERPAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebioEA2x2ERPAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebioEA2x2ERPAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebioEA2x2ERPAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebioEA2x2ERPAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebioEA2x2ERPAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebioEA2x2ERPAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebioEA2x2ERPAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebioEA2x2ERPAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebioEA2x2ERPAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebioEA2x2ERPAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA2x2ERPAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA2x2ERPAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA2x2ERPAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA2x2ERPAlert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA2x2ERPAlert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA2x2ERPAlert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA2x2ERPAlert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA2x2ERPAlert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA2x2ERPAlert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA2x2ERPAlert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA2x2ERPAlert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES { wtWebioEA2x2ERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA2x2ERPAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP
|
|
VARIABLES {
|
|
wtWebioEA2x2ERPDiagErrorIndex,
|
|
wtWebioEA2x2ERPDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebioEA12x6RelERPInOut Group
|
|
------------------------
|
|
|
|
wtWebioEA12x6RelERPInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebioEA12x6RelERPInOut 1 }
|
|
|
|
wtWebioEA12x6RelERPOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..6)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent outputs."
|
|
::= { wtWebioEA12x6RelERPInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA12x6RelERPInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA12x6RelERPInOut 3 }
|
|
|
|
wtWebioEA12x6RelERPInputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebioEA12x6RelERPInputNo }
|
|
::= { wtWebioEA12x6RelERPInputTable 1 }
|
|
|
|
WtWebioEA12x6RelERPInputEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPInputNo INTEGER,
|
|
wtWebioEA12x6RelERPInputCounter INTEGER,
|
|
wtWebioEA12x6RelERPInputCounterClear INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelERPInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA12x6RelERPInputEntry 1 }
|
|
|
|
wtWebioEA12x6RelERPInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA12x6RelERPInputEntry 2 }
|
|
|
|
wtWebioEA12x6RelERPInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebioEA12x6RelERPInputEntry 3 }
|
|
|
|
wtWebioEA12x6RelERPInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelERPInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA12x6RelERPOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA12x6RelERPInOut 5 }
|
|
|
|
wtWebioEA12x6RelERPOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebioEA12x6RelERPOutputNo }
|
|
::= { wtWebioEA12x6RelERPOutputTable 1 }
|
|
|
|
WtWebioEA12x6RelERPOutputEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPOutputNo INTEGER,
|
|
wtWebioEA12x6RelERPOutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelERPOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebioEA12x6RelERPOutputEntry 1 }
|
|
|
|
wtWebioEA12x6RelERPOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting and reading of the states of the outputs, 0-OFF, 1-ON."
|
|
::= { wtWebioEA12x6RelERPOutputEntry 2 }
|
|
|
|
wtWebioEA12x6RelERPOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-5: Digital outputs 0-5"
|
|
::= { wtWebioEA12x6RelERPInOut 6 }
|
|
|
|
wtWebioEA12x6RelERPSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4 : Bit 0-5: Mask for digital outputs 0-5
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8 : Bit 0-5: Level of digital outputs 0-5"
|
|
::= { wtWebioEA12x6RelERPInOut 7 }
|
|
|
|
-- wtWebioEA12x6RelERPSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA12x6RelERPSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA12x6RelERPSessCntrl 1 }
|
|
|
|
wtWebioEA12x6RelERPSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA12x6RelERPSessCntrl 2 }
|
|
|
|
wtWebioEA12x6RelERPSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA12x6RelERPSessCntrl 3 }
|
|
|
|
wtWebioEA12x6RelERPSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA12x6RelERPSessCntrl 4 }
|
|
|
|
wtWebioEA12x6RelERPSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA12x6RelERPSessCntrl 5 }
|
|
|
|
-- wtWebioEA12x6RelERPText Group
|
|
------------------------
|
|
|
|
wtWebioEA12x6RelERPDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA12x6RelERPText 1 }
|
|
|
|
wtWebioEA12x6RelERPDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA12x6RelERPText 2 }
|
|
|
|
wtWebioEA12x6RelERPDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA12x6RelERPText 3 }
|
|
|
|
wtWebioEA12x6RelERPDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA12x6RelERPText 4 }
|
|
|
|
-- wtWebioEA12x6RelERPTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelERPTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA12x6RelERPTimeZone 1 }
|
|
|
|
wtWebioEA12x6RelERPTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA12x6RelERPTimeZone 2 }
|
|
|
|
wtWebioEA12x6RelERPTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA12x6RelERPTimeZone 3 }
|
|
|
|
wtWebioEA12x6RelERPStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA12x6RelERPTimeZone 4 }
|
|
|
|
wtWebioEA12x6RelERPStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA12x6RelERPTimeZone 5 }
|
|
|
|
wtWebioEA12x6RelERPStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA12x6RelERPTimeZone 6 }
|
|
|
|
wtWebioEA12x6RelERPStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelERPStartMonth-January(1),
|
|
wtWebioEA12x6RelERPStartMonth-February(2),
|
|
wtWebioEA12x6RelERPStartMonth-March(3),
|
|
wtWebioEA12x6RelERPStartMonth-April(4),
|
|
wtWebioEA12x6RelERPStartMonth-May(5),
|
|
wtWebioEA12x6RelERPStartMonth-June(6),
|
|
wtWebioEA12x6RelERPStartMonth-July(7),
|
|
wtWebioEA12x6RelERPStartMonth-August(8),
|
|
wtWebioEA12x6RelERPStartMonth-September(9),
|
|
wtWebioEA12x6RelERPStartMonth-October(10),
|
|
wtWebioEA12x6RelERPStartMonth-November(11),
|
|
wtWebioEA12x6RelERPStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA12x6RelERPTimeZone 7 }
|
|
|
|
wtWebioEA12x6RelERPStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelERPStartMode-first(1),
|
|
wtWebioEA12x6RelERPStartMode-second(2),
|
|
wtWebioEA12x6RelERPStartMode-third(3),
|
|
wtWebioEA12x6RelERPStartMode-fourth(4),
|
|
wtWebioEA12x6RelERPStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA12x6RelERPTimeZone 8 }
|
|
|
|
wtWebioEA12x6RelERPStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelERPStartWday-Sunday(1),
|
|
wtWebioEA12x6RelERPStartWday-Monday(2),
|
|
wtWebioEA12x6RelERPStartWday-Tuesday(3),
|
|
wtWebioEA12x6RelERPStartWday-Thursday(4),
|
|
wtWebioEA12x6RelERPStartWday-Wednesday(5),
|
|
wtWebioEA12x6RelERPStartWday-Friday(6),
|
|
wtWebioEA12x6RelERPStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA12x6RelERPTimeZone 9 }
|
|
|
|
wtWebioEA12x6RelERPStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x6RelERPTimeZone 10 }
|
|
|
|
wtWebioEA12x6RelERPStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x6RelERPTimeZone 11 }
|
|
|
|
wtWebioEA12x6RelERPStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelERPStopMonth-January(1),
|
|
wtWebioEA12x6RelERPStopMonth-February(2),
|
|
wtWebioEA12x6RelERPStopMonth-March(3),
|
|
wtWebioEA12x6RelERPStopMonth-April(4),
|
|
wtWebioEA12x6RelERPStopMonth-May(5),
|
|
wtWebioEA12x6RelERPStopMonth-June(6),
|
|
wtWebioEA12x6RelERPStopMonth-July(7),
|
|
wtWebioEA12x6RelERPStopMonth-August(8),
|
|
wtWebioEA12x6RelERPStopMonth-September(9),
|
|
wtWebioEA12x6RelERPStopMonth-October(10),
|
|
wtWebioEA12x6RelERPStopMonth-November(11),
|
|
wtWebioEA12x6RelERPStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x6RelERPTimeZone 12 }
|
|
|
|
wtWebioEA12x6RelERPStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelERPStopMode-first(1),
|
|
wtWebioEA12x6RelERPStopMode-second(2),
|
|
wtWebioEA12x6RelERPStopMode-third(3),
|
|
wtWebioEA12x6RelERPStopMode-fourth(4),
|
|
wtWebioEA12x6RelERPStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x6RelERPTimeZone 13 }
|
|
|
|
wtWebioEA12x6RelERPStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelERPStopWday-Sunday(1),
|
|
wtWebioEA12x6RelERPStopWday-Monday(2),
|
|
wtWebioEA12x6RelERPStopWday-Tuesday(3),
|
|
wtWebioEA12x6RelERPStopWday-Thursday(4),
|
|
wtWebioEA12x6RelERPStopWday-Wednesday(5),
|
|
wtWebioEA12x6RelERPStopWday-Friday(6),
|
|
wtWebioEA12x6RelERPStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA12x6RelERPTimeZone 14 }
|
|
|
|
wtWebioEA12x6RelERPStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x6RelERPTimeZone 15 }
|
|
|
|
wtWebioEA12x6RelERPStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA12x6RelERPTimeZone 16 }
|
|
|
|
-- wtWebioEA12x6RelERPTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelERPTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA12x6RelERPTimeServer 1 }
|
|
|
|
wtWebioEA12x6RelERPTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA12x6RelERPTimeServer 2 }
|
|
|
|
wtWebioEA12x6RelERPTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA12x6RelERPTimeServer 3 }
|
|
|
|
wtWebioEA12x6RelERPTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA12x6RelERPTimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA12x6RelERPDeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelERPClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelERPDeviceClock 1 }
|
|
|
|
wtWebioEA12x6RelERPClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelERPDeviceClock 2 }
|
|
|
|
wtWebioEA12x6RelERPClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelERPDeviceClock 3 }
|
|
|
|
wtWebioEA12x6RelERPClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA12x6RelERPClockMonth-January(1),
|
|
wtWebioEA12x6RelERPClockMonth-February(2),
|
|
wtWebioEA12x6RelERPClockMonth-March(3),
|
|
wtWebioEA12x6RelERPClockMonth-April(4),
|
|
wtWebioEA12x6RelERPClockMonth-May(5),
|
|
wtWebioEA12x6RelERPClockMonth-June(6),
|
|
wtWebioEA12x6RelERPClockMonth-July(7),
|
|
wtWebioEA12x6RelERPClockMonth-August(8),
|
|
wtWebioEA12x6RelERPClockMonth-September(9),
|
|
wtWebioEA12x6RelERPClockMonth-October(10),
|
|
wtWebioEA12x6RelERPClockMonth-November(11),
|
|
wtWebioEA12x6RelERPClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelERPDeviceClock 4 }
|
|
|
|
wtWebioEA12x6RelERPClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA12x6RelERPDeviceClock 5 }
|
|
|
|
-- wtWebioEA12x6RelERPNetwork Group
|
|
------------------------
|
|
|
|
wtWebioEA12x6RelERPIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA12x6RelERPNetwork 1 }
|
|
|
|
wtWebioEA12x6RelERPSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA12x6RelERPNetwork 2 }
|
|
|
|
wtWebioEA12x6RelERPGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA12x6RelERPNetwork 3 }
|
|
|
|
wtWebioEA12x6RelERPDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA12x6RelERPNetwork 4 }
|
|
|
|
wtWebioEA12x6RelERPDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA12x6RelERPNetwork 5 }
|
|
|
|
wtWebioEA12x6RelERPAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA12x6RelERPNetwork 6 }
|
|
|
|
-- wtWebioEA12x6RelERPHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA12x6RelERPHTTP 1 }
|
|
|
|
wtWebioEA12x6RelERPGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA12x6RelERPHTTP 2 }
|
|
|
|
wtWebioEA12x6RelERPHttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelERPHTTP 3 }
|
|
|
|
wtWebioEA12x6RelERPHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA12x6RelERPHTTP 4 }
|
|
|
|
|
|
-- wtWebioEA12x6RelERPMail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA12x6RelERPMail 1 }
|
|
|
|
wtWebioEA12x6RelERPMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA12x6RelERPMail 2 }
|
|
|
|
wtWebioEA12x6RelERPMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA12x6RelERPMail 3 }
|
|
|
|
wtWebioEA12x6RelERPMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA12x6RelERPMail 4 }
|
|
|
|
wtWebioEA12x6RelERPMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA12x6RelERPMail 5 }
|
|
|
|
wtWebioEA12x6RelERPMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA12x6RelERPMail 6 }
|
|
|
|
wtWebioEA12x6RelERPMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA12x6RelERPMail 7 }
|
|
|
|
wtWebioEA12x6RelERPMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA12x6RelERPMail 8 }
|
|
|
|
|
|
-- wtWebioEA12x6RelERPSnmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA12x6RelERPSNMP 1 }
|
|
|
|
wtWebioEA12x6RelERPSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA12x6RelERPSNMP 2 }
|
|
|
|
wtWebioEA12x6RelERPSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA12x6RelERPSNMP 3 }
|
|
|
|
wtWebioEA12x6RelERPSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA12x6RelERPSNMP 4 }
|
|
|
|
wtWebioEA12x6RelERPSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA12x6RelERPSNMP 5 }
|
|
|
|
-- wtWebioEA12x6RelERPUdp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA12x6RelERPUDP 1 }
|
|
|
|
wtWebioEA12x6RelERPUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA12x6RelERPUDP 2 }
|
|
|
|
wtWebioEA12x6RelERPUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA12x6RelERPUDP 3 }
|
|
|
|
-- wtWebioEA12x6RelERPBinary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPBinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA12x6RelERPBinary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA12x6RelERPBinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA12x6RelERPBinary 2 }
|
|
|
|
wtWebioEA12x6RelERPBinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA12x6RelERPBinaryModeNo }
|
|
::= { wtWebioEA12x6RelERPBinaryIfTable 1 }
|
|
|
|
WtWebioEA12x6RelERPBinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPBinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelERPBinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA12x6RelERPBinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPBinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA12x6RelERPBinary 3 }
|
|
|
|
wtWebioEA12x6RelERPBinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA12x6RelERPBinaryModeNo }
|
|
::= { wtWebioEA12x6RelERPBinaryTable 1 }
|
|
|
|
WtWebioEA12x6RelERPBinaryEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPBinaryOperationMode OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA12x6RelERPBinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA12x6RelERPBinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA12x6RelERPBinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA12x6RelERPBinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryTcpClientInterval INTEGER,
|
|
wtWebioEA12x6RelERPBinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA12x6RelERPBinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA12x6RelERPBinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA12x6RelERPBinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA12x6RelERPBinaryConnectedPort INTEGER,
|
|
wtWebioEA12x6RelERPBinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA12x6RelERPBinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA12x6RelERPBinaryTcpClientServerHttpPort INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA12x6RelERPBinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 1 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 2 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 3 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 4 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 5 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 6 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 7 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 8 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 9 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 10 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 11 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 12 }
|
|
|
|
wtWebioEA12x6RelERPBinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 13 }
|
|
|
|
wtWebioEA12x6RelERPBinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 14 }
|
|
|
|
wtWebioEA12x6RelERPBinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 15 }
|
|
|
|
wtWebioEA12x6RelERPBinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3, Bit 0-3: Digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Digital inputs 0-7"
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 16 }
|
|
|
|
wtWebioEA12x6RelERPBinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 17 }
|
|
|
|
wtWebioEA12x6RelERPBinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 18 }
|
|
|
|
wtWebioEA12x6RelERPBinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 19 }
|
|
|
|
wtWebioEA12x6RelERPBinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 20 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 21 }
|
|
|
|
wtWebioEA12x6RelERPBinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA12x6RelERPBinaryEntry 22 }
|
|
|
|
-- wtWebioEA12x6RelERPSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA12x6RelERPSyslog 1 }
|
|
|
|
wtWebioEA12x6RelERPSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA12x6RelERPSyslog 2 }
|
|
|
|
wtWebioEA12x6RelERPSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA12x6RelERPSyslog 3 }
|
|
|
|
wtWebioEA12x6RelERPSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA12x6RelERPSyslog 4 }
|
|
|
|
-- wtWebioEA12x6RelERPFTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA12x6RelERPFTP 1 }
|
|
|
|
wtWebioEA12x6RelERPFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA12x6RelERPFTP 2 }
|
|
|
|
wtWebioEA12x6RelERPFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA12x6RelERPFTP 3 }
|
|
|
|
wtWebioEA12x6RelERPFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA12x6RelERPFTP 4 }
|
|
|
|
wtWebioEA12x6RelERPFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA12x6RelERPFTP 5 }
|
|
|
|
wtWebioEA12x6RelERPFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA12x6RelERPFTP 6 }
|
|
|
|
wtWebioEA12x6RelERPFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA12x6RelERPFTP 7 }
|
|
|
|
-- wtWebioEA12x6RelERPWayBack Group
|
|
--------------------------------
|
|
|
|
wtWebioEA12x6RelERPWayBackEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable WayBack:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : WayBack enable"
|
|
::= { wtWebioEA12x6RelERPWayBack 1 }
|
|
|
|
wtWebioEA12x6RelERPWayBackServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA12x6RelERPWayBack 2 }
|
|
|
|
wtWebioEA12x6RelERPWayBackFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP Loggin: Password of the user."
|
|
::= { wtWebioEA12x6RelERPWayBack 3 }
|
|
|
|
wtWebioEA12x6RelERPWayBackFTPResponse OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP response: return message after login."
|
|
::= { wtWebioEA12x6RelERPWayBack 4 }
|
|
|
|
wtWebioEA12x6RelERPWayBackFTPTimeOut OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP Timeout: a request must be finished within this periode of time."
|
|
::= { wtWebioEA12x6RelERPWayBack 5 }
|
|
|
|
-- wtWebioEA12x6RelERPOutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA12x6RelERPOutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA12x6RelERPOutputMode 1 }
|
|
|
|
wtWebioEA12x6RelERPOutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA12x6RelERPOutputNo }
|
|
::= { wtWebioEA12x6RelERPOutputModeTable 1 }
|
|
|
|
WtWebioEA12x6RelERPOutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPOutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA12x6RelERPOutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each set of octets corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA12x6RelERPOutputModeEntry 1 }
|
|
|
|
wtWebioEA12x6RelERPSafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA12x6RelERPOutputMode 2 }
|
|
|
|
|
|
-- wtWebioEA12x6RelERPAlarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelERPAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA12x6RelERPAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA12x6RelERPAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA12x6RelERPAlarm 2 }
|
|
|
|
wtWebioEA12x6RelERPAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA12x6RelERPAlarmNo }
|
|
::= { wtWebioEA12x6RelERPAlarmIfTable 1 }
|
|
|
|
WtWebioEA12x6RelERPAlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelERPAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..12)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA12x6RelERPAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA12x6RelERPAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA12x6RelERPAlarm 3 }
|
|
|
|
wtWebioEA12x6RelERPAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA12x6RelERPAlarmNo }
|
|
::= { wtWebioEA12x6RelERPAlarmTable 1 }
|
|
|
|
WtWebioEA12x6RelERPAlarmEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPAlarmInputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmInterval OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmEnable OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmMailAddr OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmMailSubject OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmMailText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmUdpPort INTEGER,
|
|
wtWebioEA12x6RelERPAlarmUdpText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmTcpPort INTEGER,
|
|
wtWebioEA12x6RelERPAlarmTcpText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmSyslogPort INTEGER,
|
|
wtWebioEA12x6RelERPAlarmSyslogText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmFtpFileName OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmFtpText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmFtpOption OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmTimerCron OCTET STRING,
|
|
|
|
wtWebioEA12x6RelERPAlarmMailReleaseSubject OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmMailReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmUdpReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmTcpReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmSyslogReleaseText OCTET STRING,
|
|
wtWebioEA12x6RelERPAlarmFtpReleaseText OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA12x6RelERPAlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3, Bit 0-3: Mask for digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 4, Bit 0-7: Mask for digital inputs 0-7
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7, Bit 0-3: Level of digital inputs 8-11
|
|
Bit 4-7: unused
|
|
OCTET 8, Bit 0-7: Level of digital inputs 0-7
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 11, Bit 0-7 : ANY bits of digital inputs 8-11
|
|
Bit 12-15 : unused
|
|
OCTET 12, Bit 0-7 : ANY bits of digital inputs 0-7"
|
|
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 1 }
|
|
|
|
wtWebioEA12x6RelERPAlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-5: Mask for digital outputs 0-5
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-5: Level of digital outputs 0-5
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9 : unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12: Bit 0-5: ANY bits of digital outputs 0-5"
|
|
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 2 }
|
|
|
|
wtWebioEA12x6RelERPAlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 3 }
|
|
|
|
wtWebioEA12x6RelERPAlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA12x6RelERPAlarmInputTrigger are not considered."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 4 }
|
|
|
|
wtWebioEA12x6RelERPAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 5 }
|
|
|
|
wtWebioEA12x6RelERPAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 6 }
|
|
|
|
wtWebioEA12x6RelERPAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 7 }
|
|
|
|
wtWebioEA12x6RelERPAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 8 }
|
|
|
|
wtWebioEA12x6RelERPAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 9 }
|
|
|
|
wtWebioEA12x6RelERPAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 10 }
|
|
|
|
wtWebioEA12x6RelERPAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 11 }
|
|
|
|
wtWebioEA12x6RelERPAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 12 }
|
|
|
|
wtWebioEA12x6RelERPAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 13 }
|
|
|
|
wtWebioEA12x6RelERPAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 14 }
|
|
|
|
wtWebioEA12x6RelERPAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 15 }
|
|
|
|
wtWebioEA12x6RelERPAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 16 }
|
|
|
|
wtWebioEA12x6RelERPAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 17 }
|
|
|
|
wtWebioEA12x6RelERPAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 18 }
|
|
|
|
wtWebioEA12x6RelERPAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 19 }
|
|
|
|
wtWebioEA12x6RelERPAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 20 }
|
|
|
|
wtWebioEA12x6RelERPAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 21 }
|
|
|
|
wtWebioEA12x6RelERPAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 22 }
|
|
|
|
wtWebioEA12x6RelERPAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 23 }
|
|
|
|
wtWebioEA12x6RelERPAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 24 }
|
|
|
|
wtWebioEA12x6RelERPAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 25 }
|
|
|
|
|
|
wtWebioEA12x6RelERPAlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 26 }
|
|
|
|
wtWebioEA12x6RelERPAlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 27 }
|
|
|
|
wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 28 }
|
|
|
|
wtWebioEA12x6RelERPAlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 29 }
|
|
|
|
wtWebioEA12x6RelERPAlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 30 }
|
|
|
|
wtWebioEA12x6RelERPAlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 31 }
|
|
|
|
wtWebioEA12x6RelERPAlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA12x6RelERPAlarmEntry 32 }
|
|
|
|
-- wtWebioEA12x6RelERPPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA12x6RelERPInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA12x6RelERPPorts 1 }
|
|
|
|
wtWebioEA12x6RelERPInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA12x6RelERPInputNo }
|
|
::= { wtWebioEA12x6RelERPInputPortTable 1 }
|
|
|
|
WtWebioEA12x6RelERPInputPortEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPPortInputName OCTET STRING,
|
|
wtWebioEA12x6RelERPPortInputText OCTET STRING,
|
|
wtWebioEA12x6RelERPPortInputMode OCTET STRING,
|
|
wtWebioEA12x6RelERPPortInputFilter INTEGER,
|
|
wtWebioEA12x6RelERPPortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebioEA12x6RelERPPortInputBicountInactivTimeout INTEGER
|
|
}
|
|
|
|
wtWebioEA12x6RelERPPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA12x6RelERPInputPortEntry 1 }
|
|
|
|
wtWebioEA12x6RelERPPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA12x6RelERPInputPortEntry 2 }
|
|
|
|
wtWebioEA12x6RelERPPortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-3:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 3-7: unused
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable
|
|
|
|
Selection for inputs 4-11:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Counter clear on read
|
|
Bit 0 : Change detection enable (default)"
|
|
::= { wtWebioEA12x6RelERPInputPortEntry 3 }
|
|
|
|
wtWebioEA12x6RelERPPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA12x6RelERPInputPortEntry 4 }
|
|
|
|
wtWebioEA12x6RelERPPortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x6RelERPInputPortEntry 5 }
|
|
|
|
wtWebioEA12x6RelERPPortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebioEA12x6RelERPInputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA12x6RelERPOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA12x6RelERPOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA12x6RelERPPorts 2 }
|
|
|
|
wtWebioEA12x6RelERPOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA12x6RelERPOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA12x6RelERPOutputNo }
|
|
::= { wtWebioEA12x6RelERPOutputPortTable 1 }
|
|
|
|
WtWebioEA12x6RelERPOutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA12x6RelERPPortOutputName OCTET STRING,
|
|
wtWebioEA12x6RelERPPortOutputText OCTET STRING,
|
|
wtWebioEA12x6RelERPPortOutputGroupMode OCTET STRING,
|
|
wtWebioEA12x6RelERPPortOutputSafetyState OCTET STRING,
|
|
wtWebioEA12x6RelERPPortLogicInputMask OCTET STRING,
|
|
wtWebioEA12x6RelERPPortLogicInputInverter OCTET STRING,
|
|
wtWebioEA12x6RelERPPortLogicFunction OCTET STRING,
|
|
wtWebioEA12x6RelERPPortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA12x6RelERPPortPulseDuration INTEGER,
|
|
wtWebioEA12x6RelERPPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA12x6RelERPPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 1 }
|
|
|
|
wtWebioEA12x6RelERPPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 2 }
|
|
|
|
wtWebioEA12x6RelERPPortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Unused in this device 57634"
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 3 }
|
|
|
|
wtWebioEA12x6RelERPPortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH=Relais closed, 0=LOW Relais open) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 4 }
|
|
|
|
wtWebioEA12x6RelERPPortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA12x6RelERPPortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA12x6RelERPPortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA12x6RelERPPortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA12x6RelERPPortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : inputs 8-11
|
|
Bit 4-7 : unused
|
|
OCTET 4:
|
|
Bit 0-7 : inputs 0-7"
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 5 }
|
|
|
|
wtWebioEA12x6RelERPPortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: Bit 0-3 : inputs 8-11
|
|
Bit 4-7 : unused
|
|
OCTET 4:
|
|
Bit 0-7 : inputs 0-7"
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 6 }
|
|
|
|
wtWebioEA12x6RelERPPortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 7 }
|
|
|
|
wtWebioEA12x6RelERPPortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 8 }
|
|
|
|
wtWebioEA12x6RelERPPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 9 }
|
|
|
|
wtWebioEA12x6RelERPPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA12x6RelERPPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA12x6RelERPOutputPortEntry 10 }
|
|
|
|
-- wtWebioEA12x6RelERPManufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelERPMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA12x6RelERPManufact 1 }
|
|
|
|
wtWebioEA12x6RelERPMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA12x6RelERPManufact 2 }
|
|
|
|
wtWebioEA12x6RelERPMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA12x6RelERPManufact 3 }
|
|
|
|
wtWebioEA12x6RelERPMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA12x6RelERPManufact 4 }
|
|
|
|
wtWebioEA12x6RelERPMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA12x6RelERPManufact 5 }
|
|
|
|
wtWebioEA12x6RelERPMfOrderNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer part number."
|
|
::= { wtWebioEA12x6RelERPManufact 6 }
|
|
|
|
-- wtWebioEA12x6RelERPDiag Group
|
|
----------------------------
|
|
|
|
wtWebioEA12x6RelERPDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA12x6RelERPDiag 1 }
|
|
|
|
wtWebioEA12x6RelERPDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA12x6RelERPDiag 2 }
|
|
|
|
wtWebioEA12x6RelERPDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA12x6RelERPDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA12x6RelERPDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA12x6RelERPDiagErrorMessage."
|
|
::= { wtWebioEA12x6RelERPDiag 3 }
|
|
|
|
wtWebioEA12x6RelERPDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA12x6RelERPDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA12x6RelERPDiag 4 }
|
|
|
|
wtWebioEA12x6RelERPDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA12x6RelERPDiag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA12x6RelERPAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebioEA12x6RelERPAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebioEA12x6RelERPAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebioEA12x6RelERPAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebioEA12x6RelERPAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebioEA12x6RelERPAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebioEA12x6RelERPAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebioEA12x6RelERPAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebioEA12x6RelERPAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebioEA12x6RelERPAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebioEA12x6RelERPAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebioEA12x6RelERPAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebioEA12x6RelERPAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA12x6RelERPAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA12x6RelERPAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA12x6RelERPAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA12x6RelERPAlert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA12x6RelERPAlert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA12x6RelERPAlert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA12x6RelERPAlert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA12x6RelERPAlert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA12x6RelERPAlert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA12x6RelERPAlert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA12x6RelERPAlert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES { wtWebioEA12x6RelERPAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA12x6RelERPAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA12x6RelERP
|
|
VARIABLES {
|
|
wtWebioEA12x6RelERPDiagErrorIndex,
|
|
wtWebioEA12x6RelERPDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtIpWatcherInOut Group
|
|
------------------------
|
|
|
|
wtIpWatcherInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtIpWatcherInOut 1 }
|
|
|
|
wtIpWatcherOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtIpWatcherInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtIpWatcherInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtIpWatcherInOut 3 }
|
|
|
|
wtIpWatcherInputEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtIpWatcherInputNo }
|
|
::= { wtIpWatcherInputTable 1 }
|
|
|
|
WtIpWatcherInputEntry ::= SEQUENCE {
|
|
wtIpWatcherInputNo INTEGER,
|
|
wtIpWatcherInputCounter INTEGER,
|
|
wtIpWatcherInputCounterClear INTEGER,
|
|
wtIpWatcherInputState INTEGER
|
|
|
|
}
|
|
|
|
wtIpWatcherInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtIpWatcherInputEntry 1 }
|
|
|
|
wtIpWatcherInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtIpWatcherInputEntry 2 }
|
|
|
|
wtIpWatcherInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtIpWatcherInputEntry 3 }
|
|
|
|
wtIpWatcherInputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtIpWatcherInputEntry 4 }
|
|
|
|
wtIpWatcherInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtIpWatcherInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtIpWatcherOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtIpWatcherInOut 5 }
|
|
|
|
wtIpWatcherOutputEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtIpWatcherOutputNo }
|
|
::= { wtIpWatcherOutputTable 1 }
|
|
|
|
WtIpWatcherOutputEntry ::= SEQUENCE {
|
|
wtIpWatcherOutputNo INTEGER,
|
|
wtIpWatcherOutputState INTEGER
|
|
}
|
|
|
|
wtIpWatcherOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtIpWatcherOutputEntry 1 }
|
|
|
|
wtIpWatcherOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtIpWatcherOutputEntry 2 }
|
|
|
|
|
|
wtIpWatcherOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtIpWatcherInOut 6 }
|
|
|
|
wtIpWatcherSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1"
|
|
::= { wtIpWatcherInOut 7 }
|
|
|
|
-- Alarm Output Interface Table
|
|
|
|
wtIpWatcherAlarmOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherAlarmOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices.."
|
|
::= { wtIpWatcherInOut 8 }
|
|
|
|
wtIpWatcherAlarmOutputEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherAlarmOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index reference."
|
|
INDEX { wtIpWatcherAlarmNo }
|
|
::= { wtIpWatcherAlarmOutputTable 1 }
|
|
|
|
WtIpWatcherAlarmOutputEntry ::= SEQUENCE {
|
|
wtIpWatcherAlarmOutputState INTEGER,
|
|
wtIpWatcherAlarmTriggerState INTEGER
|
|
}
|
|
|
|
wtIpWatcherAlarmOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the alarm, 0-OFF, 1-ON."
|
|
::= { wtIpWatcherAlarmOutputEntry 1 }
|
|
|
|
wtIpWatcherAlarmTriggerState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the trigger condition, 0-OFF, 1-ON."
|
|
::= { wtIpWatcherAlarmOutputEntry 2 }
|
|
|
|
-- wtIpWatcherSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtIpWatcherSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtIpWatcherSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtIpWatcherSessCntrl 1 }
|
|
|
|
wtIpWatcherSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtIpWatcherSessCntrl 2 }
|
|
|
|
wtIpWatcherSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtIpWatcherSessCntrl 3 }
|
|
|
|
wtIpWatcherSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtIpWatcherSessCntrl 4 }
|
|
|
|
wtIpWatcherSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtIpWatcherSessCntrl 5 }
|
|
|
|
-- wtIpWatcherText Group
|
|
------------------------
|
|
|
|
wtIpWatcherDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtIpWatcherText 1 }
|
|
|
|
wtIpWatcherDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtIpWatcherText 2 }
|
|
|
|
wtIpWatcherDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtIpWatcherText 3 }
|
|
|
|
wtIpWatcherDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtIpWatcherText 4 }
|
|
|
|
-- wtIpWatcherTimeZone Group
|
|
----------------------------
|
|
|
|
wtIpWatcherTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtIpWatcherTimeZone 1 }
|
|
|
|
wtIpWatcherTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtIpWatcherTimeZone 2 }
|
|
|
|
wtIpWatcherTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtIpWatcherTimeZone 3 }
|
|
|
|
wtIpWatcherStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtIpWatcherTimeZone 4 }
|
|
|
|
wtIpWatcherStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtIpWatcherTimeZone 5 }
|
|
|
|
wtIpWatcherStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtIpWatcherTimeZone 6 }
|
|
|
|
wtIpWatcherStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcherStartMonth-January(1),
|
|
wtIpWatcherStartMonth-February(2),
|
|
wtIpWatcherStartMonth-March(3),
|
|
wtIpWatcherStartMonth-April(4),
|
|
wtIpWatcherStartMonth-May(5),
|
|
wtIpWatcherStartMonth-June(6),
|
|
wtIpWatcherStartMonth-July(7),
|
|
wtIpWatcherStartMonth-August(8),
|
|
wtIpWatcherStartMonth-September(9),
|
|
wtIpWatcherStartMonth-October(10),
|
|
wtIpWatcherStartMonth-November(11),
|
|
wtIpWatcherStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtIpWatcherTimeZone 7 }
|
|
|
|
wtIpWatcherStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcherStartMode-first(1),
|
|
wtIpWatcherStartMode-second(2),
|
|
wtIpWatcherStartMode-third(3),
|
|
wtIpWatcherStartMode-fourth(4),
|
|
wtIpWatcherStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtIpWatcherTimeZone 8 }
|
|
|
|
wtIpWatcherStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcherStartWday-Sunday(1),
|
|
wtIpWatcherStartWday-Monday(2),
|
|
wtIpWatcherStartWday-Tuesday(3),
|
|
wtIpWatcherStartWday-Thursday(4),
|
|
wtIpWatcherStartWday-Wednesday(5),
|
|
wtIpWatcherStartWday-Friday(6),
|
|
wtIpWatcherStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtIpWatcherTimeZone 9 }
|
|
|
|
wtIpWatcherStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtIpWatcherTimeZone 10 }
|
|
|
|
wtIpWatcherStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtIpWatcherTimeZone 11 }
|
|
|
|
wtIpWatcherStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcherStopMonth-January(1),
|
|
wtIpWatcherStopMonth-February(2),
|
|
wtIpWatcherStopMonth-March(3),
|
|
wtIpWatcherStopMonth-April(4),
|
|
wtIpWatcherStopMonth-May(5),
|
|
wtIpWatcherStopMonth-June(6),
|
|
wtIpWatcherStopMonth-July(7),
|
|
wtIpWatcherStopMonth-August(8),
|
|
wtIpWatcherStopMonth-September(9),
|
|
wtIpWatcherStopMonth-October(10),
|
|
wtIpWatcherStopMonth-November(11),
|
|
wtIpWatcherStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtIpWatcherTimeZone 12 }
|
|
|
|
wtIpWatcherStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcherStopMode-first(1),
|
|
wtIpWatcherStopMode-second(2),
|
|
wtIpWatcherStopMode-third(3),
|
|
wtIpWatcherStopMode-fourth(4),
|
|
wtIpWatcherStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtIpWatcherTimeZone 13 }
|
|
|
|
wtIpWatcherStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcherStopWday-Sunday(1),
|
|
wtIpWatcherStopWday-Monday(2),
|
|
wtIpWatcherStopWday-Tuesday(3),
|
|
wtIpWatcherStopWday-Thursday(4),
|
|
wtIpWatcherStopWday-Wednesday(5),
|
|
wtIpWatcherStopWday-Friday(6),
|
|
wtIpWatcherStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtIpWatcherTimeZone 14 }
|
|
|
|
wtIpWatcherStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtIpWatcherTimeZone 15 }
|
|
|
|
wtIpWatcherStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtIpWatcherTimeZone 16 }
|
|
|
|
-- wtIpWatcherTimeServer Group
|
|
----------------------------
|
|
|
|
wtIpWatcherTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtIpWatcherTimeServer 1 }
|
|
|
|
wtIpWatcherTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtIpWatcherTimeServer 2 }
|
|
|
|
wtIpWatcherTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtIpWatcherTimeServer 3 }
|
|
|
|
wtIpWatcherTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtIpWatcherTimeServer 4 }
|
|
|
|
|
|
-- wtIpWatcherDeviceClock Group
|
|
----------------------------
|
|
|
|
wtIpWatcherClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtIpWatcherDeviceClock 1 }
|
|
|
|
wtIpWatcherClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtIpWatcherDeviceClock 2 }
|
|
|
|
wtIpWatcherClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtIpWatcherDeviceClock 3 }
|
|
|
|
wtIpWatcherClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcherClockMonth-January(1),
|
|
wtIpWatcherClockMonth-February(2),
|
|
wtIpWatcherClockMonth-March(3),
|
|
wtIpWatcherClockMonth-April(4),
|
|
wtIpWatcherClockMonth-May(5),
|
|
wtIpWatcherClockMonth-June(6),
|
|
wtIpWatcherClockMonth-July(7),
|
|
wtIpWatcherClockMonth-August(8),
|
|
wtIpWatcherClockMonth-September(9),
|
|
wtIpWatcherClockMonth-October(10),
|
|
wtIpWatcherClockMonth-November(11),
|
|
wtIpWatcherClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtIpWatcherDeviceClock 4 }
|
|
|
|
wtIpWatcherClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtIpWatcherDeviceClock 5 }
|
|
|
|
-- wtIpWatcherNetwork Group
|
|
------------------------
|
|
|
|
wtIpWatcherIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtIpWatcherNetwork 1 }
|
|
|
|
wtIpWatcherSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtIpWatcherNetwork 2 }
|
|
|
|
wtIpWatcherGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtIpWatcherNetwork 3 }
|
|
|
|
wtIpWatcherDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtIpWatcherNetwork 4 }
|
|
|
|
wtIpWatcherDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtIpWatcherNetwork 5 }
|
|
|
|
wtIpWatcherAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtIpWatcherNetwork 6 }
|
|
|
|
-- wtIpWatcherHTTP Group
|
|
--------------------------------
|
|
|
|
wtIpWatcherHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtIpWatcherHTTP 4 }
|
|
|
|
|
|
-- wtIpWatcherMail Group
|
|
--------------------------------
|
|
|
|
wtIpWatcherMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtIpWatcherMail 1 }
|
|
|
|
wtIpWatcherMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtIpWatcherMail 2 }
|
|
|
|
wtIpWatcherMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtIpWatcherMail 3 }
|
|
|
|
wtIpWatcherMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtIpWatcherMail 4 }
|
|
|
|
wtIpWatcherMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtIpWatcherMail 5 }
|
|
|
|
wtIpWatcherMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtIpWatcherMail 6 }
|
|
|
|
wtIpWatcherMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtIpWatcherMail 7 }
|
|
|
|
wtIpWatcherMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtIpWatcherMail 8 }
|
|
|
|
|
|
-- wtIpWatcherSnmp Group
|
|
--------------------------------
|
|
|
|
wtIpWatcherSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtIpWatcherSNMP 1 }
|
|
|
|
wtIpWatcherSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtIpWatcherSNMP 2 }
|
|
|
|
wtIpWatcherSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtIpWatcherSNMP 3 }
|
|
|
|
wtIpWatcherSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtIpWatcherSNMP 4 }
|
|
|
|
wtIpWatcherSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtIpWatcherSNMP 5 }
|
|
|
|
-- wtIpWatcherUDP Group
|
|
--------------------------------
|
|
|
|
wtIpWatcherUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtIpWatcherUDP 1 }
|
|
|
|
wtIpWatcherUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtIpWatcherUDP 2 }
|
|
|
|
wtIpWatcherUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtIpWatcherUDP 3 }
|
|
|
|
-- wtIpWatcherSyslog Group
|
|
--------------------------------
|
|
|
|
wtIpWatcherSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtIpWatcherSyslog 1 }
|
|
|
|
wtIpWatcherSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtIpWatcherSyslog 2 }
|
|
|
|
wtIpWatcherSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtIpWatcherSyslog 3 }
|
|
|
|
wtIpWatcherSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtIpWatcherSyslog 4 }
|
|
|
|
-- wtIpWatcherFTP Group
|
|
--------------------------------
|
|
|
|
wtIpWatcherFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtIpWatcherFTP 1 }
|
|
|
|
wtIpWatcherFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtIpWatcherFTP 2 }
|
|
|
|
wtIpWatcherFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtIpWatcherFTP 3 }
|
|
|
|
wtIpWatcherFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtIpWatcherFTP 4 }
|
|
|
|
wtIpWatcherFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtIpWatcherFTP 5 }
|
|
|
|
wtIpWatcherFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtIpWatcherFTP 6 }
|
|
|
|
wtIpWatcherFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtIpWatcherFTP 7 }
|
|
|
|
-- wtIpWatcherIpList Group
|
|
----------------------------
|
|
|
|
wtIpWatcherIpListCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Ip addresses."
|
|
::= { wtIpWatcherIpList 1 }
|
|
|
|
-- IpList Interface Table
|
|
|
|
wtIpWatcherIpListIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherIpListIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of inices."
|
|
::= { wtIpWatcherIpList 2 }
|
|
|
|
wtIpWatcherIpListIfEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherIpListIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table entry."
|
|
INDEX { wtIpWatcherIpListNo }
|
|
::= { wtIpWatcherIpListIfTable 1 }
|
|
|
|
WtIpWatcherIpListIfEntry ::= SEQUENCE {
|
|
wtIpWatcherIpListNo INTEGER
|
|
}
|
|
|
|
wtIpWatcherIpListNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..999)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List number of this entry."
|
|
::= { wtIpWatcherIpListIfEntry 1 }
|
|
|
|
-- IpList Table
|
|
|
|
wtIpWatcherIpListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherIpListEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of ip addresses."
|
|
::= { wtIpWatcherIpList 3 }
|
|
|
|
wtIpWatcherIpListEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherIpListEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List entry."
|
|
INDEX { wtIpWatcherIpListNo }
|
|
::= { wtIpWatcherIpListTable 1 }
|
|
|
|
WtIpWatcherIpListEntry ::= SEQUENCE {
|
|
wtIpWatcherIpListName OCTET STRING,
|
|
wtIpWatcherIpListPort INTEGER,
|
|
wtIpWatcherIpListService OCTET STRING,
|
|
wtIpWatcherIpListEnable OCTET STRING,
|
|
wtIpWatcherIpListAlias OCTET STRING
|
|
}
|
|
|
|
wtIpWatcherIpListName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address."
|
|
::= { wtIpWatcherIpListEntry 1 }
|
|
|
|
wtIpWatcherIpListPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number, zero in the case of broadcast or Ping."
|
|
::= { wtIpWatcherIpListEntry 2 }
|
|
|
|
wtIpWatcherIpListService OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded scan mode, only one mode can be selected at a particular time:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Ping enable
|
|
Bit 1-7: unused"
|
|
::= { wtIpWatcherIpListEntry 3 }
|
|
|
|
wtIpWatcherIpListEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: enabled in Alarm 1
|
|
Bit 1: enabled in Alarm 2
|
|
Bit 2: enabled in Alarm 3
|
|
Bit 3: enabled in Alarm 4
|
|
Bit 4-7: unused"
|
|
::= { wtIpWatcherIpListEntry 4 }
|
|
|
|
wtIpWatcherIpListAlias OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alias Name"
|
|
::= { wtIpWatcherIpListEntry 5 }
|
|
|
|
|
|
-- wtIpWatcherAlarm Group
|
|
----------------------------
|
|
|
|
wtIpWatcherAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtIpWatcherAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtIpWatcherAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtIpWatcherAlarm 2 }
|
|
|
|
wtIpWatcherAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtIpWatcherAlarmNo }
|
|
::= { wtIpWatcherAlarmIfTable 1 }
|
|
|
|
WtIpWatcherAlarmIfEntry ::= SEQUENCE {
|
|
wtIpWatcherAlarmNo INTEGER
|
|
}
|
|
|
|
wtIpWatcherAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtIpWatcherAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtIpWatcherAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtIpWatcherAlarm 3 }
|
|
|
|
wtIpWatcherAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtIpWatcherAlarmNo }
|
|
::= { wtIpWatcherAlarmTable 1 }
|
|
|
|
WtIpWatcherAlarmEntry ::= SEQUENCE {
|
|
wtIpWatcherAlarmInterval OCTET STRING,
|
|
wtIpWatcherAlarmEnable OCTET STRING,
|
|
wtIpWatcherAlarmMailAddr OCTET STRING,
|
|
wtIpWatcherAlarmMailSubject OCTET STRING,
|
|
wtIpWatcherAlarmMailText OCTET STRING,
|
|
wtIpWatcherAlarmSnmpManagerIP OCTET STRING,
|
|
wtIpWatcherAlarmSnmpTrapText OCTET STRING,
|
|
wtIpWatcherAlarmUdpIpAddr OCTET STRING,
|
|
wtIpWatcherAlarmUdpPort INTEGER,
|
|
wtIpWatcherAlarmUdpText OCTET STRING,
|
|
wtIpWatcherAlarmTcpIpAddr OCTET STRING,
|
|
wtIpWatcherAlarmTcpPort INTEGER,
|
|
wtIpWatcherAlarmTcpText OCTET STRING,
|
|
wtIpWatcherAlarmSyslogIpAddr OCTET STRING,
|
|
wtIpWatcherAlarmSyslogPort INTEGER,
|
|
wtIpWatcherAlarmSyslogText OCTET STRING,
|
|
wtIpWatcherAlarmFtpDataPort OCTET STRING,
|
|
wtIpWatcherAlarmFtpFileName OCTET STRING,
|
|
wtIpWatcherAlarmFtpText OCTET STRING,
|
|
wtIpWatcherAlarmFtpOption OCTET STRING,
|
|
wtIpWatcherAlarmTimerCron OCTET STRING,
|
|
|
|
wtIpWatcherAlarmMailReleaseSubject OCTET STRING,
|
|
wtIpWatcherAlarmMailReleaseText OCTET STRING,
|
|
wtIpWatcherAlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtIpWatcherAlarmUdpReleaseText OCTET STRING,
|
|
wtIpWatcherAlarmTcpReleaseText OCTET STRING,
|
|
wtIpWatcherAlarmSyslogReleaseText OCTET STRING,
|
|
wtIpWatcherAlarmFtpReleaseText OCTET STRING,
|
|
|
|
wtIpWatcherAlarmName OCTET STRING,
|
|
wtIpWatcherAlarmGlobalEnable OCTET STRING,
|
|
wtIpWatcherAlarmCounterClear OCTET STRING,
|
|
wtIpWatcherAlarmAckEnable OCTET STRING,
|
|
wtIpWatcherAlarmAckPort INTEGER,
|
|
wtIpWatcherAlarmSetPort INTEGER,
|
|
|
|
wtIpWatcherAlarmMailTrgClearSubject OCTET STRING,
|
|
wtIpWatcherAlarmMailTrgClearText OCTET STRING,
|
|
wtIpWatcherAlarmSnmpTrapTrgClearText OCTET STRING,
|
|
wtIpWatcherAlarmUdpTrgClearText OCTET STRING,
|
|
wtIpWatcherAlarmTcpTrgClearText OCTET STRING,
|
|
wtIpWatcherAlarmSyslogTrgClearText OCTET STRING,
|
|
wtIpWatcherAlarmFtpTrgClearText OCTET STRING,
|
|
|
|
wtIpWatcherAlarmMailTrapTxEnable OCTET STRING,
|
|
wtIpWatcherAlarmSnmpTrapTrapTxEnable OCTET STRING,
|
|
wtIpWatcherAlarmUdpTrapTxEnable OCTET STRING,
|
|
wtIpWatcherAlarmTcpTrapTxEnable OCTET STRING,
|
|
wtIpWatcherAlarmSyslogTrapTxEnable OCTET STRING,
|
|
wtIpWatcherAlarmFtpTrapTxEnable OCTET STRING,
|
|
|
|
wtIpWatcherAlarmTriggerCount INTEGER,
|
|
wtIpWatcherAlarmPollingRate INTEGER
|
|
}
|
|
|
|
|
|
|
|
|
|
wtIpWatcherAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtIpWatcherAlarmEntry 5 }
|
|
|
|
wtIpWatcherAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtIpWatcherAlarmEntry 6 }
|
|
|
|
wtIpWatcherAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtIpWatcherAlarmEntry 7 }
|
|
|
|
wtIpWatcherAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtIpWatcherAlarmEntry 8 }
|
|
|
|
wtIpWatcherAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtIpWatcherAlarmEntry 9 }
|
|
|
|
wtIpWatcherAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtIpWatcherAlarmEntry 10 }
|
|
|
|
wtIpWatcherAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtIpWatcherAlarmEntry 11 }
|
|
|
|
wtIpWatcherAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtIpWatcherAlarmEntry 12 }
|
|
|
|
wtIpWatcherAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtIpWatcherAlarmEntry 13 }
|
|
|
|
wtIpWatcherAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtIpWatcherAlarmEntry 14 }
|
|
|
|
wtIpWatcherAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtIpWatcherAlarmEntry 15 }
|
|
|
|
wtIpWatcherAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtIpWatcherAlarmEntry 16 }
|
|
|
|
wtIpWatcherAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtIpWatcherAlarmEntry 17 }
|
|
|
|
wtIpWatcherAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtIpWatcherAlarmEntry 18 }
|
|
|
|
wtIpWatcherAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtIpWatcherAlarmEntry 19 }
|
|
|
|
wtIpWatcherAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtIpWatcherAlarmEntry 20 }
|
|
|
|
wtIpWatcherAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtIpWatcherAlarmEntry 21 }
|
|
|
|
wtIpWatcherAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtIpWatcherAlarmEntry 22 }
|
|
|
|
wtIpWatcherAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtIpWatcherAlarmEntry 23 }
|
|
|
|
wtIpWatcherAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtIpWatcherAlarmEntry 24 }
|
|
|
|
wtIpWatcherAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtIpWatcherAlarmEntry 25 }
|
|
|
|
wtIpWatcherAlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtIpWatcherAlarmEntry 26 }
|
|
|
|
wtIpWatcherAlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtIpWatcherAlarmEntry 27 }
|
|
|
|
wtIpWatcherAlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtIpWatcherAlarmEntry 28 }
|
|
|
|
wtIpWatcherAlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtIpWatcherAlarmEntry 29 }
|
|
|
|
wtIpWatcherAlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtIpWatcherAlarmEntry 30 }
|
|
|
|
wtIpWatcherAlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtIpWatcherAlarmEntry 31 }
|
|
|
|
wtIpWatcherAlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtIpWatcherAlarmEntry 32 }
|
|
|
|
wtIpWatcherAlarmName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the alarm."
|
|
::= { wtIpWatcherAlarmEntry 33 }
|
|
|
|
wtIpWatcherAlarmGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
Die OCTETS werden bitweise interpretiert.
|
|
Bit 0 entspricht dem LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Alarm enable"
|
|
::= { wtIpWatcherAlarmEntry 34 }
|
|
|
|
wtIpWatcherAlarmCounterClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Counter clear on Alarm acknowledge
|
|
Bit 0 : Counter clear on Alarm send"
|
|
::= { wtIpWatcherAlarmEntry 35 }
|
|
|
|
|
|
wtIpWatcherAlarmAckEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Software acknowledge enable
|
|
Bit 0 : Hardware acknowledge enable"
|
|
::= { wtIpWatcherAlarmEntry 36 }
|
|
|
|
|
|
wtIpWatcherAlarmAckPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the input, which clears the alarm (1-6)."
|
|
::= { wtIpWatcherAlarmEntry 37 }
|
|
|
|
wtIpWatcherAlarmSetPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the output, which will be set by this alarm (1-6).
|
|
The configuration of pulse mode and polarity defined in the port output section is used."
|
|
::= { wtIpWatcherAlarmEntry 38 }
|
|
|
|
wtIpWatcherAlarmMailTrgClearSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtIpWatcherAlarmEntry 39 }
|
|
|
|
wtIpWatcherAlarmMailTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtIpWatcherAlarmEntry 40 }
|
|
|
|
wtIpWatcherAlarmSnmpTrapTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtIpWatcherAlarmEntry 41 }
|
|
|
|
wtIpWatcherAlarmUdpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtIpWatcherAlarmEntry 42 }
|
|
|
|
wtIpWatcherAlarmTcpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtIpWatcherAlarmEntry 43 }
|
|
|
|
wtIpWatcherAlarmSyslogTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtIpWatcherAlarmEntry 44 }
|
|
|
|
wtIpWatcherAlarmFtpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtIpWatcherAlarmEntry 45 }
|
|
|
|
wtIpWatcherAlarmMailTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcherAlarmEntry 46 }
|
|
|
|
wtIpWatcherAlarmSnmpTrapTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcherAlarmEntry 47 }
|
|
|
|
wtIpWatcherAlarmUdpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcherAlarmEntry 48 }
|
|
|
|
wtIpWatcherAlarmTcpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcherAlarmEntry 49 }
|
|
|
|
wtIpWatcherAlarmSyslogTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcherAlarmEntry 50 }
|
|
|
|
wtIpWatcherAlarmFtpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcherAlarmEntry 51 }
|
|
|
|
wtIpWatcherAlarmTriggerCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm will be send if the trigger condition occours TriggerCount times."
|
|
::= { wtIpWatcherAlarmEntry 52 }
|
|
|
|
wtIpWatcherAlarmPollingRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds."
|
|
::= { wtIpWatcherAlarmEntry 53 }
|
|
|
|
-- wtIpWatcherPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtIpWatcherInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtIpWatcherPorts 1 }
|
|
|
|
wtIpWatcherInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtIpWatcherInputNo }
|
|
::= { wtIpWatcherInputPortTable 1 }
|
|
|
|
WtIpWatcherInputPortEntry ::= SEQUENCE {
|
|
wtIpWatcherPortInputName OCTET STRING,
|
|
wtIpWatcherPortInputText OCTET STRING,
|
|
wtIpWatcherPortInputFilter INTEGER
|
|
}
|
|
|
|
wtIpWatcherPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtIpWatcherInputPortEntry 1 }
|
|
|
|
wtIpWatcherPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtIpWatcherInputPortEntry 2 }
|
|
|
|
wtIpWatcherPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtIpWatcherInputPortEntry 4 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtIpWatcherOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcherOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtIpWatcherPorts 2 }
|
|
|
|
wtIpWatcherOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcherOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtIpWatcherOutputNo }
|
|
::= { wtIpWatcherOutputPortTable 1 }
|
|
|
|
WtIpWatcherOutputPortEntry ::= SEQUENCE {
|
|
wtIpWatcherPortOutputName OCTET STRING,
|
|
wtIpWatcherPortOutputText OCTET STRING,
|
|
wtIpWatcherPortPulseDuration INTEGER,
|
|
wtIpWatcherPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtIpWatcherPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtIpWatcherOutputPortEntry 1 }
|
|
|
|
wtIpWatcherPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtIpWatcherOutputPortEntry 2 }
|
|
|
|
wtIpWatcherPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtIpWatcherOutputPortEntry 9 }
|
|
|
|
wtIpWatcherPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtIpWatcherPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtIpWatcherOutputPortEntry 10 }
|
|
|
|
-- wtIpWatcherManufact Group
|
|
----------------------------
|
|
|
|
wtIpWatcherMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtIpWatcherManufact 1 }
|
|
|
|
wtIpWatcherMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtIpWatcherManufact 2 }
|
|
|
|
wtIpWatcherMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtIpWatcherManufact 3 }
|
|
|
|
wtIpWatcherMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtIpWatcherManufact 4 }
|
|
|
|
wtIpWatcherMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtIpWatcherManufact 5 }
|
|
|
|
-- wtIpWatcherDiag Group
|
|
----------------------------
|
|
|
|
wtIpWatcherDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtIpWatcherDiag 1 }
|
|
|
|
wtIpWatcherDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtIpWatcherDiag 2 }
|
|
|
|
wtIpWatcherDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtIpWatcherDiagErrorMessage.
|
|
Errors are numbered from 1 to wtIpWatcherDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtIpWatcherDiagErrorMessage."
|
|
::= { wtIpWatcherDiag 3 }
|
|
|
|
wtIpWatcherDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtIpWatcherDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtIpWatcherDiag 4 }
|
|
|
|
wtIpWatcherDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtIpWatcherDiag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtIpWatcherAlert1 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtIpWatcherAlert2 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtIpWatcherAlert3 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtIpWatcherAlert4 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtIpWatcherAlert5 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtIpWatcherAlert6 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtIpWatcherAlert7 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtIpWatcherAlert8 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtIpWatcherAlert9 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtIpWatcherAlert10 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtIpWatcherAlert11 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtIpWatcherAlert12 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtIpWatcherAlert13 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtIpWatcherAlert14 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtIpWatcherAlert15 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtIpWatcherAlert16 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtIpWatcherAlert17 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtIpWatcherAlert18 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtIpWatcherAlert19 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtIpWatcherAlert20 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtIpWatcherAlert21 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtIpWatcherAlert22 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtIpWatcherAlert23 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtIpWatcherAlert24 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtIpWatcherAlert25 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 91
|
|
|
|
wtIpWatcherAlert26 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 92
|
|
|
|
wtIpWatcherAlert27 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 93
|
|
|
|
wtIpWatcherAlert28 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 94
|
|
|
|
wtIpWatcherAlert29 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 95
|
|
|
|
wtIpWatcherAlert30 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 96
|
|
|
|
wtIpWatcherAlert31 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 97
|
|
|
|
wtIpWatcherAlert32 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 98
|
|
|
|
wtIpWatcherAlert33 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 99
|
|
|
|
wtIpWatcherAlert34 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 100
|
|
|
|
wtIpWatcherAlert35 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 101
|
|
|
|
wtIpWatcherAlert36 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES { wtIpWatcherAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 102
|
|
|
|
wtIpWatcherAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher
|
|
VARIABLES {
|
|
wtIpWatcherDiagErrorIndex,
|
|
wtIpWatcherDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebioEA2x2-24VInOut Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2-24VInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebioEA2x2-24VInOut 1 }
|
|
|
|
wtWebioEA2x2-24VOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebioEA2x2-24VInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA2x2-24VInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA2x2-24VInOut 3 }
|
|
|
|
wtWebioEA2x2-24VInputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebioEA2x2-24VInputNo }
|
|
::= { wtWebioEA2x2-24VInputTable 1 }
|
|
|
|
WtWebioEA2x2-24VInputEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VInputNo INTEGER,
|
|
wtWebioEA2x2-24VInputCounter INTEGER,
|
|
wtWebioEA2x2-24VInputCounterClear INTEGER,
|
|
wtWebioEA2x2-24VInputState INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2-24VInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA2x2-24VInputEntry 1 }
|
|
|
|
wtWebioEA2x2-24VInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA2x2-24VInputEntry 2 }
|
|
|
|
wtWebioEA2x2-24VInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebioEA2x2-24VInputEntry 3 }
|
|
|
|
wtWebioEA2x2-24VInputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA2x2-24VInputEntry 4 }
|
|
|
|
wtWebioEA2x2-24VInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtWebioEA2x2-24VInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA2x2-24VOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA2x2-24VInOut 5 }
|
|
|
|
wtWebioEA2x2-24VOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebioEA2x2-24VOutputNo }
|
|
::= { wtWebioEA2x2-24VOutputTable 1 }
|
|
|
|
WtWebioEA2x2-24VOutputEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VOutputNo INTEGER,
|
|
wtWebioEA2x2-24VOutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2-24VOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebioEA2x2-24VOutputEntry 1 }
|
|
|
|
wtWebioEA2x2-24VOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA2x2-24VOutputEntry 2 }
|
|
|
|
|
|
wtWebioEA2x2-24VOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtWebioEA2x2-24VInOut 6 }
|
|
|
|
wtWebioEA2x2-24VSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1"
|
|
::= { wtWebioEA2x2-24VInOut 7 }
|
|
|
|
-- wtWebioEA2x2-24VSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA2x2-24VSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA2x2-24VSessCntrl 1 }
|
|
|
|
wtWebioEA2x2-24VSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA2x2-24VSessCntrl 2 }
|
|
|
|
wtWebioEA2x2-24VSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA2x2-24VSessCntrl 3 }
|
|
|
|
wtWebioEA2x2-24VSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA2x2-24VSessCntrl 4 }
|
|
|
|
wtWebioEA2x2-24VSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA2x2-24VSessCntrl 5 }
|
|
|
|
-- wtWebioEA2x2-24VText Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2-24VDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2-24VText 1 }
|
|
|
|
wtWebioEA2x2-24VDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2-24VText 2 }
|
|
|
|
wtWebioEA2x2-24VDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2-24VText 3 }
|
|
|
|
wtWebioEA2x2-24VDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2-24VText 4 }
|
|
|
|
-- wtWebioEA2x2-24VTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2-24VTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA2x2-24VTimeZone 1 }
|
|
|
|
wtWebioEA2x2-24VTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA2x2-24VTimeZone 2 }
|
|
|
|
wtWebioEA2x2-24VTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA2x2-24VTimeZone 3 }
|
|
|
|
wtWebioEA2x2-24VStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA2x2-24VTimeZone 4 }
|
|
|
|
wtWebioEA2x2-24VStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA2x2-24VTimeZone 5 }
|
|
|
|
wtWebioEA2x2-24VStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA2x2-24VTimeZone 6 }
|
|
|
|
wtWebioEA2x2-24VStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2-24VStartMonth-January(1),
|
|
wtWebioEA2x2-24VStartMonth-February(2),
|
|
wtWebioEA2x2-24VStartMonth-March(3),
|
|
wtWebioEA2x2-24VStartMonth-April(4),
|
|
wtWebioEA2x2-24VStartMonth-May(5),
|
|
wtWebioEA2x2-24VStartMonth-June(6),
|
|
wtWebioEA2x2-24VStartMonth-July(7),
|
|
wtWebioEA2x2-24VStartMonth-August(8),
|
|
wtWebioEA2x2-24VStartMonth-September(9),
|
|
wtWebioEA2x2-24VStartMonth-October(10),
|
|
wtWebioEA2x2-24VStartMonth-November(11),
|
|
wtWebioEA2x2-24VStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA2x2-24VTimeZone 7 }
|
|
|
|
wtWebioEA2x2-24VStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2-24VStartMode-first(1),
|
|
wtWebioEA2x2-24VStartMode-second(2),
|
|
wtWebioEA2x2-24VStartMode-third(3),
|
|
wtWebioEA2x2-24VStartMode-fourth(4),
|
|
wtWebioEA2x2-24VStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA2x2-24VTimeZone 8 }
|
|
|
|
wtWebioEA2x2-24VStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2-24VStartWday-Sunday(1),
|
|
wtWebioEA2x2-24VStartWday-Monday(2),
|
|
wtWebioEA2x2-24VStartWday-Tuesday(3),
|
|
wtWebioEA2x2-24VStartWday-Thursday(4),
|
|
wtWebioEA2x2-24VStartWday-Wednesday(5),
|
|
wtWebioEA2x2-24VStartWday-Friday(6),
|
|
wtWebioEA2x2-24VStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA2x2-24VTimeZone 9 }
|
|
|
|
wtWebioEA2x2-24VStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2-24VTimeZone 10 }
|
|
|
|
wtWebioEA2x2-24VStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2-24VTimeZone 11 }
|
|
|
|
wtWebioEA2x2-24VStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2-24VStopMonth-January(1),
|
|
wtWebioEA2x2-24VStopMonth-February(2),
|
|
wtWebioEA2x2-24VStopMonth-March(3),
|
|
wtWebioEA2x2-24VStopMonth-April(4),
|
|
wtWebioEA2x2-24VStopMonth-May(5),
|
|
wtWebioEA2x2-24VStopMonth-June(6),
|
|
wtWebioEA2x2-24VStopMonth-July(7),
|
|
wtWebioEA2x2-24VStopMonth-August(8),
|
|
wtWebioEA2x2-24VStopMonth-September(9),
|
|
wtWebioEA2x2-24VStopMonth-October(10),
|
|
wtWebioEA2x2-24VStopMonth-November(11),
|
|
wtWebioEA2x2-24VStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2-24VTimeZone 12 }
|
|
|
|
wtWebioEA2x2-24VStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2-24VStopMode-first(1),
|
|
wtWebioEA2x2-24VStopMode-second(2),
|
|
wtWebioEA2x2-24VStopMode-third(3),
|
|
wtWebioEA2x2-24VStopMode-fourth(4),
|
|
wtWebioEA2x2-24VStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2-24VTimeZone 13 }
|
|
|
|
wtWebioEA2x2-24VStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2-24VStopWday-Sunday(1),
|
|
wtWebioEA2x2-24VStopWday-Monday(2),
|
|
wtWebioEA2x2-24VStopWday-Tuesday(3),
|
|
wtWebioEA2x2-24VStopWday-Thursday(4),
|
|
wtWebioEA2x2-24VStopWday-Wednesday(5),
|
|
wtWebioEA2x2-24VStopWday-Friday(6),
|
|
wtWebioEA2x2-24VStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2-24VTimeZone 14 }
|
|
|
|
wtWebioEA2x2-24VStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2-24VTimeZone 15 }
|
|
|
|
wtWebioEA2x2-24VStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2-24VTimeZone 16 }
|
|
|
|
-- wtWebioEA2x2-24VTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2-24VTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA2x2-24VTimeServer 1 }
|
|
|
|
wtWebioEA2x2-24VTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA2x2-24VTimeServer 2 }
|
|
|
|
wtWebioEA2x2-24VTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA2x2-24VTimeServer 3 }
|
|
|
|
wtWebioEA2x2-24VTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA2x2-24VTimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA2x2-24VDeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2-24VClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA2x2-24VDeviceClock 1 }
|
|
|
|
wtWebioEA2x2-24VClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA2x2-24VDeviceClock 2 }
|
|
|
|
wtWebioEA2x2-24VClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2-24VDeviceClock 3 }
|
|
|
|
wtWebioEA2x2-24VClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2-24VClockMonth-January(1),
|
|
wtWebioEA2x2-24VClockMonth-February(2),
|
|
wtWebioEA2x2-24VClockMonth-March(3),
|
|
wtWebioEA2x2-24VClockMonth-April(4),
|
|
wtWebioEA2x2-24VClockMonth-May(5),
|
|
wtWebioEA2x2-24VClockMonth-June(6),
|
|
wtWebioEA2x2-24VClockMonth-July(7),
|
|
wtWebioEA2x2-24VClockMonth-August(8),
|
|
wtWebioEA2x2-24VClockMonth-September(9),
|
|
wtWebioEA2x2-24VClockMonth-October(10),
|
|
wtWebioEA2x2-24VClockMonth-November(11),
|
|
wtWebioEA2x2-24VClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2-24VDeviceClock 4 }
|
|
|
|
wtWebioEA2x2-24VClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2-24VDeviceClock 5 }
|
|
|
|
-- wtWebioEA2x2-24VNetwork Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2-24VIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA2x2-24VNetwork 1 }
|
|
|
|
wtWebioEA2x2-24VSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA2x2-24VNetwork 2 }
|
|
|
|
wtWebioEA2x2-24VGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA2x2-24VNetwork 3 }
|
|
|
|
wtWebioEA2x2-24VDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA2x2-24VNetwork 4 }
|
|
|
|
wtWebioEA2x2-24VDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA2x2-24VNetwork 5 }
|
|
|
|
wtWebioEA2x2-24VAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA2x2-24VNetwork 6 }
|
|
|
|
-- wtWebioEA2x2-24VHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA2x2-24VHTTP 1 }
|
|
|
|
wtWebioEA2x2-24VGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA2x2-24VHTTP 2 }
|
|
|
|
wtWebioEA2x2-24VHttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2-24VHTTP 3 }
|
|
|
|
wtWebioEA2x2-24VHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA2x2-24VHTTP 4 }
|
|
|
|
|
|
-- wtWebioEA2x2-24VMail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA2x2-24VMail 1 }
|
|
|
|
wtWebioEA2x2-24VMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA2x2-24VMail 2 }
|
|
|
|
wtWebioEA2x2-24VMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA2x2-24VMail 3 }
|
|
|
|
wtWebioEA2x2-24VMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA2x2-24VMail 4 }
|
|
|
|
wtWebioEA2x2-24VMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA2x2-24VMail 5 }
|
|
|
|
wtWebioEA2x2-24VMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA2x2-24VMail 6 }
|
|
|
|
wtWebioEA2x2-24VMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA2x2-24VMail 7 }
|
|
|
|
wtWebioEA2x2-24VMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA2x2-24VMail 8 }
|
|
|
|
|
|
-- wtWebioEA2x2-24VSnmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA2x2-24VSNMP 1 }
|
|
|
|
wtWebioEA2x2-24VSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA2x2-24VSNMP 2 }
|
|
|
|
wtWebioEA2x2-24VSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA2x2-24VSNMP 3 }
|
|
|
|
wtWebioEA2x2-24VSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA2x2-24VSNMP 4 }
|
|
|
|
wtWebioEA2x2-24VSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA2x2-24VSNMP 5 }
|
|
|
|
-- wtWebioEA2x2-24VUDP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA2x2-24VUDP 1 }
|
|
|
|
wtWebioEA2x2-24VUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA2x2-24VUDP 2 }
|
|
|
|
wtWebioEA2x2-24VUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA2x2-24VUDP 3 }
|
|
|
|
-- wtWebioEA2x2-24VBinary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VBinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA2x2-24VBinary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA2x2-24VBinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA2x2-24VBinary 2 }
|
|
|
|
wtWebioEA2x2-24VBinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA2x2-24VBinaryModeNo }
|
|
::= { wtWebioEA2x2-24VBinaryIfTable 1 }
|
|
|
|
WtWebioEA2x2-24VBinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VBinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2-24VBinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA2x2-24VBinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VBinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA2x2-24VBinary 3 }
|
|
|
|
wtWebioEA2x2-24VBinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA2x2-24VBinaryModeNo }
|
|
::= { wtWebioEA2x2-24VBinaryTable 1 }
|
|
|
|
WtWebioEA2x2-24VBinaryEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VBinaryOperationMode OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA2x2-24VBinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA2x2-24VBinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA2x2-24VBinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA2x2-24VBinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryTcpClientInterval INTEGER,
|
|
wtWebioEA2x2-24VBinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA2x2-24VBinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA2x2-24VBinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA2x2-24VBinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA2x2-24VBinaryConnectedPort INTEGER,
|
|
wtWebioEA2x2-24VBinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA2x2-24VBinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA2x2-24VBinaryTcpClientServerHttpPort INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2-24VBinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA2x2-24VBinaryEntry 1 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 2 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2-24VBinaryEntry 3 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2-24VBinaryEntry 4 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 5 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 6 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 7 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 8 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 9 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2-24VBinaryEntry 10 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 11 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2-24VBinaryEntry 12 }
|
|
|
|
wtWebioEA2x2-24VBinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 13 }
|
|
|
|
wtWebioEA2x2-24VBinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 14 }
|
|
|
|
wtWebioEA2x2-24VBinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 15 }
|
|
|
|
wtWebioEA2x2-24VBinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2-24VBinaryEntry 16 }
|
|
|
|
wtWebioEA2x2-24VBinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 17 }
|
|
|
|
wtWebioEA2x2-24VBinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2-24VBinaryEntry 18 }
|
|
|
|
wtWebioEA2x2-24VBinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 19 }
|
|
|
|
wtWebioEA2x2-24VBinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 20 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 21 }
|
|
|
|
wtWebioEA2x2-24VBinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA2x2-24VBinaryEntry 22 }
|
|
|
|
-- wtWebioEA2x2-24VSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA2x2-24VSyslog 1 }
|
|
|
|
wtWebioEA2x2-24VSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA2x2-24VSyslog 2 }
|
|
|
|
wtWebioEA2x2-24VSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA2x2-24VSyslog 3 }
|
|
|
|
wtWebioEA2x2-24VSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA2x2-24VSyslog 4 }
|
|
|
|
-- wtWebioEA2x2-24VFTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2-24VFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA2x2-24VFTP 1 }
|
|
|
|
wtWebioEA2x2-24VFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA2x2-24VFTP 2 }
|
|
|
|
wtWebioEA2x2-24VFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA2x2-24VFTP 3 }
|
|
|
|
wtWebioEA2x2-24VFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA2x2-24VFTP 4 }
|
|
|
|
wtWebioEA2x2-24VFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA2x2-24VFTP 5 }
|
|
|
|
wtWebioEA2x2-24VFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA2x2-24VFTP 6 }
|
|
|
|
wtWebioEA2x2-24VFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA2x2-24VFTP 7 }
|
|
|
|
-- wtWebioEA2x2-24VOutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA2x2-24VOutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA2x2-24VOutputMode 1 }
|
|
|
|
wtWebioEA2x2-24VOutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA2x2-24VOutputNo }
|
|
::= { wtWebioEA2x2-24VOutputModeTable 1 }
|
|
|
|
WtWebioEA2x2-24VOutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VOutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA2x2-24VOutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA2x2-24VOutputModeEntry 1 }
|
|
|
|
wtWebioEA2x2-24VSafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA2x2-24VOutputMode 2 }
|
|
|
|
wtWebioEA2x2-24VPowerSupplyEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this enable bit turns on the intarnal 24V power supply of the outputs.
|
|
All currents out must not exceed 150mA. At overcurrent condition the power supply will
|
|
be shut down automatically. To reset the ocvercurrent protection circuit
|
|
write 1 into wtWebioEA2x2-24VDiagErrorClear.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Power Supply enable"
|
|
::= { wtWebioEA2x2-24VOutputMode 4 }
|
|
|
|
-- wtWebioEA2x2-24VAlarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2-24VAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA2x2-24VAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA2x2-24VAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA2x2-24VAlarm 2 }
|
|
|
|
wtWebioEA2x2-24VAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA2x2-24VAlarmNo }
|
|
::= { wtWebioEA2x2-24VAlarmIfTable 1 }
|
|
|
|
WtWebioEA2x2-24VAlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2-24VAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA2x2-24VAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA2x2-24VAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA2x2-24VAlarm 3 }
|
|
|
|
wtWebioEA2x2-24VAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA2x2-24VAlarmNo }
|
|
::= { wtWebioEA2x2-24VAlarmTable 1 }
|
|
|
|
WtWebioEA2x2-24VAlarmEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VAlarmInputTrigger OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmInterval OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmEnable OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmMailAddr OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmMailSubject OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmMailText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmUdpPort INTEGER,
|
|
wtWebioEA2x2-24VAlarmUdpText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmTcpPort INTEGER,
|
|
wtWebioEA2x2-24VAlarmTcpText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmSyslogPort INTEGER,
|
|
wtWebioEA2x2-24VAlarmSyslogText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmFtpFileName OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmFtpText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmFtpOption OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmTimerCron OCTET STRING,
|
|
|
|
wtWebioEA2x2-24VAlarmMailReleaseSubject OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmMailReleaseText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmUdpReleaseText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmTcpReleaseText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmSyslogReleaseText OCTET STRING,
|
|
wtWebioEA2x2-24VAlarmFtpReleaseText OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA2x2-24VAlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital inputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital inputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1"
|
|
|
|
::= { wtWebioEA2x2-24VAlarmEntry 1 }
|
|
|
|
wtWebioEA2x2-24VAlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1"
|
|
|
|
::= { wtWebioEA2x2-24VAlarmEntry 2 }
|
|
|
|
wtWebioEA2x2-24VAlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : unused"
|
|
::= { wtWebioEA2x2-24VAlarmEntry 3 }
|
|
|
|
wtWebioEA2x2-24VAlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA2x2-24VAlarmInputTrigger are not considered."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 4 }
|
|
|
|
wtWebioEA2x2-24VAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 5 }
|
|
|
|
wtWebioEA2x2-24VAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA2x2-24VAlarmEntry 6 }
|
|
|
|
wtWebioEA2x2-24VAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 7 }
|
|
|
|
wtWebioEA2x2-24VAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 8 }
|
|
|
|
wtWebioEA2x2-24VAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA2x2-24VAlarmEntry 9 }
|
|
|
|
wtWebioEA2x2-24VAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 10 }
|
|
|
|
wtWebioEA2x2-24VAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 11 }
|
|
|
|
wtWebioEA2x2-24VAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 12 }
|
|
|
|
wtWebioEA2x2-24VAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 13 }
|
|
|
|
wtWebioEA2x2-24VAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 14 }
|
|
|
|
wtWebioEA2x2-24VAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 15 }
|
|
|
|
wtWebioEA2x2-24VAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 16 }
|
|
|
|
wtWebioEA2x2-24VAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 17 }
|
|
|
|
wtWebioEA2x2-24VAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 18 }
|
|
|
|
wtWebioEA2x2-24VAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 19 }
|
|
|
|
wtWebioEA2x2-24VAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 20 }
|
|
|
|
wtWebioEA2x2-24VAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 21 }
|
|
|
|
wtWebioEA2x2-24VAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 22 }
|
|
|
|
wtWebioEA2x2-24VAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 23 }
|
|
|
|
wtWebioEA2x2-24VAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA2x2-24VAlarmEntry 24 }
|
|
|
|
wtWebioEA2x2-24VAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 25 }
|
|
|
|
wtWebioEA2x2-24VAlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 26 }
|
|
|
|
wtWebioEA2x2-24VAlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA2x2-24VAlarmEntry 27 }
|
|
|
|
wtWebioEA2x2-24VAlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 28 }
|
|
|
|
wtWebioEA2x2-24VAlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 29 }
|
|
|
|
wtWebioEA2x2-24VAlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 30 }
|
|
|
|
wtWebioEA2x2-24VAlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 31 }
|
|
|
|
wtWebioEA2x2-24VAlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA2x2-24VAlarmEntry 32 }
|
|
|
|
|
|
-- wtWebioEA2x2-24VPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA2x2-24VInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA2x2-24VPorts 1 }
|
|
|
|
wtWebioEA2x2-24VInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA2x2-24VInputNo }
|
|
::= { wtWebioEA2x2-24VInputPortTable 1 }
|
|
|
|
WtWebioEA2x2-24VInputPortEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VPortInputName OCTET STRING,
|
|
wtWebioEA2x2-24VPortInputText OCTET STRING,
|
|
wtWebioEA2x2-24VPortInputMode OCTET STRING,
|
|
wtWebioEA2x2-24VPortInputFilter INTEGER,
|
|
wtWebioEA2x2-24VPortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebioEA2x2-24VPortInputBicountInactivTimeout INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2-24VPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA2x2-24VInputPortEntry 1 }
|
|
|
|
wtWebioEA2x2-24VPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA2x2-24VInputPortEntry 2 }
|
|
|
|
wtWebioEA2x2-24VPortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable"
|
|
::= { wtWebioEA2x2-24VInputPortEntry 3 }
|
|
|
|
wtWebioEA2x2-24VPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA2x2-24VInputPortEntry 4 }
|
|
|
|
wtWebioEA2x2-24VPortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2-24VInputPortEntry 5 }
|
|
|
|
wtWebioEA2x2-24VPortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebioEA2x2-24VInputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA2x2-24VOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2-24VOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA2x2-24VPorts 2 }
|
|
|
|
wtWebioEA2x2-24VOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2-24VOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA2x2-24VOutputNo }
|
|
::= { wtWebioEA2x2-24VOutputPortTable 1 }
|
|
|
|
WtWebioEA2x2-24VOutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA2x2-24VPortOutputName OCTET STRING,
|
|
wtWebioEA2x2-24VPortOutputText OCTET STRING,
|
|
wtWebioEA2x2-24VPortOutputGroupMode OCTET STRING,
|
|
wtWebioEA2x2-24VPortOutputSafetyState OCTET STRING,
|
|
wtWebioEA2x2-24VPortLogicInputMask OCTET STRING,
|
|
wtWebioEA2x2-24VPortLogicInputInverter OCTET STRING,
|
|
wtWebioEA2x2-24VPortLogicFunction OCTET STRING,
|
|
wtWebioEA2x2-24VPortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA2x2-24VPortPulseDuration INTEGER,
|
|
wtWebioEA2x2-24VPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA2x2-24VPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 1 }
|
|
|
|
wtWebioEA2x2-24VPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 2 }
|
|
|
|
wtWebioEA2x2-24VPortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one ouput bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for ouputs 0-1:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : ouputs 0,1 disconnected (default)
|
|
Bit 1 : ouputs 0+1 connected"
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 3 }
|
|
|
|
wtWebioEA2x2-24VPortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 4 }
|
|
|
|
wtWebioEA2x2-24VPortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA2x2-24VPortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA2x2-24VPortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA2x2-24VPortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA2x2-24VPortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 5 }
|
|
|
|
wtWebioEA2x2-24VPortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 6 }
|
|
|
|
wtWebioEA2x2-24VPortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 7 }
|
|
|
|
wtWebioEA2x2-24VPortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 8 }
|
|
|
|
wtWebioEA2x2-24VPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 9 }
|
|
|
|
wtWebioEA2x2-24VPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA2x2-24VPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2-24VOutputPortEntry 10 }
|
|
|
|
-- wtWebioEA2x2-24VManufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2-24VMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA2x2-24VManufact 1 }
|
|
|
|
wtWebioEA2x2-24VMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA2x2-24VManufact 2 }
|
|
|
|
wtWebioEA2x2-24VMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA2x2-24VManufact 3 }
|
|
|
|
wtWebioEA2x2-24VMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA2x2-24VManufact 4 }
|
|
|
|
wtWebioEA2x2-24VMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA2x2-24VManufact 5 }
|
|
|
|
-- wtWebioEA2x2-24VDiag Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2-24VDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA2x2-24VDiag 1 }
|
|
|
|
wtWebioEA2x2-24VDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA2x2-24VDiag 2 }
|
|
|
|
wtWebioEA2x2-24VDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA2x2-24VDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA2x2-24VDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA2x2-24VDiagErrorMessage."
|
|
::= { wtWebioEA2x2-24VDiag 3 }
|
|
|
|
wtWebioEA2x2-24VDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA2x2-24VDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA2x2-24VDiag 4 }
|
|
|
|
wtWebioEA2x2-24VDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA2x2-24VDiag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA2x2-24VAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebioEA2x2-24VAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebioEA2x2-24VAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebioEA2x2-24VAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebioEA2x2-24VAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebioEA2x2-24VAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebioEA2x2-24VAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebioEA2x2-24VAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebioEA2x2-24VAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebioEA2x2-24VAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebioEA2x2-24VAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebioEA2x2-24VAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebioEA2x2-24VAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA2x2-24VAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA2x2-24VAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA2x2-24VAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA2x2-24VAlert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA2x2-24VAlert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA2x2-24VAlert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA2x2-24VAlert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA2x2-24VAlert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA2x2-24VAlert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA2x2-24VAlert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA2x2-24VAlert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES { wtWebioEA2x2-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA2x2-24VAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2-24V
|
|
VARIABLES {
|
|
wtWebioEA2x2-24VDiagErrorIndex,
|
|
wtWebioEA2x2-24VDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtWebioEA2x2ERP-24VInOut Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2ERP-24VInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtWebioEA2x2ERP-24VInOut 1 }
|
|
|
|
wtWebioEA2x2ERP-24VOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtWebioEA2x2ERP-24VInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtWebioEA2x2ERP-24VInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtWebioEA2x2ERP-24VInOut 3 }
|
|
|
|
wtWebioEA2x2ERP-24VInputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtWebioEA2x2ERP-24VInputNo }
|
|
::= { wtWebioEA2x2ERP-24VInputTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VInputEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VInputNo INTEGER,
|
|
wtWebioEA2x2ERP-24VInputCounter INTEGER,
|
|
wtWebioEA2x2ERP-24VInputCounterClear INTEGER,
|
|
wtWebioEA2x2ERP-24VInputState INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtWebioEA2x2ERP-24VInputEntry 1 }
|
|
|
|
wtWebioEA2x2ERP-24VInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtWebioEA2x2ERP-24VInputEntry 2 }
|
|
|
|
wtWebioEA2x2ERP-24VInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtWebioEA2x2ERP-24VInputEntry 3 }
|
|
|
|
wtWebioEA2x2ERP-24VInputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA2x2ERP-24VInputEntry 4 }
|
|
|
|
wtWebioEA2x2ERP-24VInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtWebioEA2x2ERP-24VInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtWebioEA2x2ERP-24VOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtWebioEA2x2ERP-24VInOut 5 }
|
|
|
|
wtWebioEA2x2ERP-24VOutputEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtWebioEA2x2ERP-24VOutputNo }
|
|
::= { wtWebioEA2x2ERP-24VOutputTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VOutputEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VOutputNo INTEGER,
|
|
wtWebioEA2x2ERP-24VOutputState INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtWebioEA2x2ERP-24VOutputEntry 1 }
|
|
|
|
wtWebioEA2x2ERP-24VOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtWebioEA2x2ERP-24VOutputEntry 2 }
|
|
|
|
|
|
wtWebioEA2x2ERP-24VOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtWebioEA2x2ERP-24VInOut 6 }
|
|
|
|
wtWebioEA2x2ERP-24VSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1"
|
|
::= { wtWebioEA2x2ERP-24VInOut 7 }
|
|
|
|
-- wtWebioEA2x2ERP-24VSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebioEA2x2ERP-24VSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebioEA2x2ERP-24VSessCntrl 1 }
|
|
|
|
wtWebioEA2x2ERP-24VSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtWebioEA2x2ERP-24VSessCntrl 2 }
|
|
|
|
wtWebioEA2x2ERP-24VSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtWebioEA2x2ERP-24VSessCntrl 3 }
|
|
|
|
wtWebioEA2x2ERP-24VSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebioEA2x2ERP-24VSessCntrl 4 }
|
|
|
|
wtWebioEA2x2ERP-24VSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebioEA2x2ERP-24VSessCntrl 5 }
|
|
|
|
-- wtWebioEA2x2ERP-24VText Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2ERP-24VDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2ERP-24VText 1 }
|
|
|
|
wtWebioEA2x2ERP-24VDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2ERP-24VText 2 }
|
|
|
|
wtWebioEA2x2ERP-24VDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2ERP-24VText 3 }
|
|
|
|
wtWebioEA2x2ERP-24VDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebioEA2x2ERP-24VText 4 }
|
|
|
|
-- wtWebioEA2x2ERP-24VTimeZone Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERP-24VTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 1 }
|
|
|
|
wtWebioEA2x2ERP-24VTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 2 }
|
|
|
|
wtWebioEA2x2ERP-24VTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 3 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 4 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 5 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 6 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERP-24VStartMonth-January(1),
|
|
wtWebioEA2x2ERP-24VStartMonth-February(2),
|
|
wtWebioEA2x2ERP-24VStartMonth-March(3),
|
|
wtWebioEA2x2ERP-24VStartMonth-April(4),
|
|
wtWebioEA2x2ERP-24VStartMonth-May(5),
|
|
wtWebioEA2x2ERP-24VStartMonth-June(6),
|
|
wtWebioEA2x2ERP-24VStartMonth-July(7),
|
|
wtWebioEA2x2ERP-24VStartMonth-August(8),
|
|
wtWebioEA2x2ERP-24VStartMonth-September(9),
|
|
wtWebioEA2x2ERP-24VStartMonth-October(10),
|
|
wtWebioEA2x2ERP-24VStartMonth-November(11),
|
|
wtWebioEA2x2ERP-24VStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 7 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERP-24VStartMode-first(1),
|
|
wtWebioEA2x2ERP-24VStartMode-second(2),
|
|
wtWebioEA2x2ERP-24VStartMode-third(3),
|
|
wtWebioEA2x2ERP-24VStartMode-fourth(4),
|
|
wtWebioEA2x2ERP-24VStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 8 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERP-24VStartWday-Sunday(1),
|
|
wtWebioEA2x2ERP-24VStartWday-Monday(2),
|
|
wtWebioEA2x2ERP-24VStartWday-Tuesday(3),
|
|
wtWebioEA2x2ERP-24VStartWday-Thursday(4),
|
|
wtWebioEA2x2ERP-24VStartWday-Wednesday(5),
|
|
wtWebioEA2x2ERP-24VStartWday-Friday(6),
|
|
wtWebioEA2x2ERP-24VStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 9 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 10 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 11 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERP-24VStopMonth-January(1),
|
|
wtWebioEA2x2ERP-24VStopMonth-February(2),
|
|
wtWebioEA2x2ERP-24VStopMonth-March(3),
|
|
wtWebioEA2x2ERP-24VStopMonth-April(4),
|
|
wtWebioEA2x2ERP-24VStopMonth-May(5),
|
|
wtWebioEA2x2ERP-24VStopMonth-June(6),
|
|
wtWebioEA2x2ERP-24VStopMonth-July(7),
|
|
wtWebioEA2x2ERP-24VStopMonth-August(8),
|
|
wtWebioEA2x2ERP-24VStopMonth-September(9),
|
|
wtWebioEA2x2ERP-24VStopMonth-October(10),
|
|
wtWebioEA2x2ERP-24VStopMonth-November(11),
|
|
wtWebioEA2x2ERP-24VStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 12 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERP-24VStopMode-first(1),
|
|
wtWebioEA2x2ERP-24VStopMode-second(2),
|
|
wtWebioEA2x2ERP-24VStopMode-third(3),
|
|
wtWebioEA2x2ERP-24VStopMode-fourth(4),
|
|
wtWebioEA2x2ERP-24VStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 13 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERP-24VStopWday-Sunday(1),
|
|
wtWebioEA2x2ERP-24VStopWday-Monday(2),
|
|
wtWebioEA2x2ERP-24VStopWday-Tuesday(3),
|
|
wtWebioEA2x2ERP-24VStopWday-Thursday(4),
|
|
wtWebioEA2x2ERP-24VStopWday-Wednesday(5),
|
|
wtWebioEA2x2ERP-24VStopWday-Friday(6),
|
|
wtWebioEA2x2ERP-24VStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 14 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 15 }
|
|
|
|
wtWebioEA2x2ERP-24VStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebioEA2x2ERP-24VTimeZone 16 }
|
|
|
|
-- wtWebioEA2x2ERP-24VTimeServer Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERP-24VTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebioEA2x2ERP-24VTimeServer 1 }
|
|
|
|
wtWebioEA2x2ERP-24VTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebioEA2x2ERP-24VTimeServer 2 }
|
|
|
|
wtWebioEA2x2ERP-24VTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebioEA2x2ERP-24VTimeServer 3 }
|
|
|
|
wtWebioEA2x2ERP-24VTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebioEA2x2ERP-24VTimeServer 4 }
|
|
|
|
|
|
-- wtWebioEA2x2ERP-24VDeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERP-24VClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERP-24VDeviceClock 1 }
|
|
|
|
wtWebioEA2x2ERP-24VClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERP-24VDeviceClock 2 }
|
|
|
|
wtWebioEA2x2ERP-24VClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERP-24VDeviceClock 3 }
|
|
|
|
wtWebioEA2x2ERP-24VClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebioEA2x2ERP-24VClockMonth-January(1),
|
|
wtWebioEA2x2ERP-24VClockMonth-February(2),
|
|
wtWebioEA2x2ERP-24VClockMonth-March(3),
|
|
wtWebioEA2x2ERP-24VClockMonth-April(4),
|
|
wtWebioEA2x2ERP-24VClockMonth-May(5),
|
|
wtWebioEA2x2ERP-24VClockMonth-June(6),
|
|
wtWebioEA2x2ERP-24VClockMonth-July(7),
|
|
wtWebioEA2x2ERP-24VClockMonth-August(8),
|
|
wtWebioEA2x2ERP-24VClockMonth-September(9),
|
|
wtWebioEA2x2ERP-24VClockMonth-October(10),
|
|
wtWebioEA2x2ERP-24VClockMonth-November(11),
|
|
wtWebioEA2x2ERP-24VClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERP-24VDeviceClock 4 }
|
|
|
|
wtWebioEA2x2ERP-24VClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebioEA2x2ERP-24VDeviceClock 5 }
|
|
|
|
-- wtWebioEA2x2ERP-24VNetwork Group
|
|
------------------------
|
|
|
|
wtWebioEA2x2ERP-24VIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebioEA2x2ERP-24VNetwork 1 }
|
|
|
|
wtWebioEA2x2ERP-24VSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebioEA2x2ERP-24VNetwork 2 }
|
|
|
|
wtWebioEA2x2ERP-24VGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebioEA2x2ERP-24VNetwork 3 }
|
|
|
|
wtWebioEA2x2ERP-24VDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebioEA2x2ERP-24VNetwork 4 }
|
|
|
|
wtWebioEA2x2ERP-24VDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebioEA2x2ERP-24VNetwork 5 }
|
|
|
|
wtWebioEA2x2ERP-24VAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtWebioEA2x2ERP-24VNetwork 6 }
|
|
|
|
-- wtWebioEA2x2ERP-24VHTTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VStartup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page, more than one page must not be selected:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2: user.htm
|
|
Bit 1: home.htm
|
|
Bit 0: index.htm"
|
|
::= { wtWebioEA2x2ERP-24VHTTP 1 }
|
|
|
|
wtWebioEA2x2ERP-24VGetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device (Header) or a HTTP header (HTTP):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebioEA2x2ERP-24VHTTP 2 }
|
|
|
|
wtWebioEA2x2ERP-24VHttpInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2ERP-24VHTTP 3 }
|
|
|
|
wtWebioEA2x2ERP-24VHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebioEA2x2ERP-24VHTTP 4 }
|
|
|
|
|
|
-- wtWebioEA2x2ERP-24VMail Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebioEA2x2ERP-24VMail 1 }
|
|
|
|
wtWebioEA2x2ERP-24VMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebioEA2x2ERP-24VMail 2 }
|
|
|
|
wtWebioEA2x2ERP-24VMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebioEA2x2ERP-24VMail 3 }
|
|
|
|
wtWebioEA2x2ERP-24VMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebioEA2x2ERP-24VMail 4 }
|
|
|
|
wtWebioEA2x2ERP-24VMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebioEA2x2ERP-24VMail 5 }
|
|
|
|
wtWebioEA2x2ERP-24VMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebioEA2x2ERP-24VMail 6 }
|
|
|
|
wtWebioEA2x2ERP-24VMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebioEA2x2ERP-24VMail 7 }
|
|
|
|
wtWebioEA2x2ERP-24VMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebioEA2x2ERP-24VMail 8 }
|
|
|
|
|
|
-- wtWebioEA2x2ERP-24VSnmp Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebioEA2x2ERP-24VSNMP 1 }
|
|
|
|
wtWebioEA2x2ERP-24VSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebioEA2x2ERP-24VSNMP 2 }
|
|
|
|
wtWebioEA2x2ERP-24VSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebioEA2x2ERP-24VSNMP 3 }
|
|
|
|
wtWebioEA2x2ERP-24VSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebioEA2x2ERP-24VSNMP 4 }
|
|
|
|
wtWebioEA2x2ERP-24VSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA2x2ERP-24VSNMP 5 }
|
|
|
|
-- wtWebioEA2x2ERP-24VUDP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebioEA2x2ERP-24VUDP 1 }
|
|
|
|
wtWebioEA2x2ERP-24VUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebioEA2x2ERP-24VUDP 2 }
|
|
|
|
wtWebioEA2x2ERP-24VUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtWebioEA2x2ERP-24VUDP 3 }
|
|
|
|
-- wtWebioEA2x2ERP-24VBinary Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VBinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebioEA2x2ERP-24VBinary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebioEA2x2ERP-24VBinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebioEA2x2ERP-24VBinary 2 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VBinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebioEA2x2ERP-24VBinaryModeNo }
|
|
::= { wtWebioEA2x2ERP-24VBinaryIfTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VBinaryIfEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VBinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VBinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebioEA2x2ERP-24VBinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebioEA2x2ERP-24VBinary 3 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VBinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebioEA2x2ERP-24VBinaryModeNo }
|
|
::= { wtWebioEA2x2ERP-24VBinaryTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VBinaryEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VBinaryOperationMode OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryTcpServerLocalPort INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientLocalPort INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientServerPort INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientInactivity INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientInterval INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerLocalPort INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerRemotePort INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerInterval INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebioEA2x2ERP-24VBinaryConnectedPort INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryConnectedIpAddr IpAddress,
|
|
wtWebioEA2x2ERP-24VBinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientServerHttpPort INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VBinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 1 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 2 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 3 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 4 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 5 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 6 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 7 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 8 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 9 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 10 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 11 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 12 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 13 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 14 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 15 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input bits.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital inputs 0-1"
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 16 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 17 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 18 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 19 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 20 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 21 }
|
|
|
|
wtWebioEA2x2ERP-24VBinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebioEA2x2ERP-24VBinaryEntry 22 }
|
|
|
|
-- wtWebioEA2x2ERP-24VSyslog Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebioEA2x2ERP-24VSyslog 1 }
|
|
|
|
wtWebioEA2x2ERP-24VSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebioEA2x2ERP-24VSyslog 2 }
|
|
|
|
wtWebioEA2x2ERP-24VSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebioEA2x2ERP-24VSyslog 3 }
|
|
|
|
wtWebioEA2x2ERP-24VSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebioEA2x2ERP-24VSyslog 4 }
|
|
|
|
-- wtWebioEA2x2ERP-24VFTP Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebioEA2x2ERP-24VFTP 1 }
|
|
|
|
wtWebioEA2x2ERP-24VFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA2x2ERP-24VFTP 2 }
|
|
|
|
wtWebioEA2x2ERP-24VFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebioEA2x2ERP-24VFTP 3 }
|
|
|
|
wtWebioEA2x2ERP-24VFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebioEA2x2ERP-24VFTP 4 }
|
|
|
|
wtWebioEA2x2ERP-24VFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebioEA2x2ERP-24VFTP 5 }
|
|
|
|
wtWebioEA2x2ERP-24VFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebioEA2x2ERP-24VFTP 6 }
|
|
|
|
wtWebioEA2x2ERP-24VFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebioEA2x2ERP-24VFTP 7 }
|
|
|
|
-- wtWebioEA2x2ERP-24VWayBack Group
|
|
--------------------------------
|
|
|
|
wtWebioEA2x2ERP-24VWayBackEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable WayBack:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : WayBack enable"
|
|
::= { wtWebioEA2x2ERP-24VWayBack 1 }
|
|
|
|
wtWebioEA2x2ERP-24VWayBackServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebioEA2x2ERP-24VWayBack 2 }
|
|
|
|
wtWebioEA2x2ERP-24VWayBackFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP Loggin: Password of the user."
|
|
::= { wtWebioEA2x2ERP-24VWayBack 3 }
|
|
|
|
wtWebioEA2x2ERP-24VWayBackFTPResponse OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP response: return message after login."
|
|
::= { wtWebioEA2x2ERP-24VWayBack 4 }
|
|
|
|
wtWebioEA2x2ERP-24VWayBackFTPTimeOut OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"WayBack FTP Timeout: a request must be finished within this periode of time."
|
|
::= { wtWebioEA2x2ERP-24VWayBack 5 }
|
|
|
|
-- wtWebioEA2x2ERP-24VOutputMode Group
|
|
--------------------------------
|
|
|
|
-- OutputMode Table
|
|
|
|
wtWebioEA2x2ERP-24VOutputModeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of output mode configurations dependent on the output indices."
|
|
::= { wtWebioEA2x2ERP-24VOutputMode 1 }
|
|
|
|
wtWebioEA2x2ERP-24VOutputModeEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VOutputModeEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output mode configurations of the individual outputs."
|
|
INDEX { wtWebioEA2x2ERP-24VOutputNo }
|
|
::= { wtWebioEA2x2ERP-24VOutputModeTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VOutputModeEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VOutputModeBit OCTET STRING
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VOutputModeBit OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Logic
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebioEA2x2ERP-24VOutputModeEntry 1 }
|
|
|
|
wtWebioEA2x2ERP-24VSafetyTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"After this period of time (multiple of 100ms) without receiving data
|
|
outputs switch to their Safety States. For each output a independend safety state
|
|
could be defined."
|
|
::= { wtWebioEA2x2ERP-24VOutputMode 2 }
|
|
|
|
wtWebioEA2x2ERP-24VLoadControlEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the function of automatic load control can be enabled. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Load Control enable"
|
|
::= { wtWebioEA2x2ERP-24VOutputMode 3 }
|
|
|
|
wtWebioEA2x2ERP-24VPowerSupplyEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this enable bit turns on the intarnal 24V power supply of the outputs.
|
|
All currents out must not exceed 150mA. At overcurrent condition the power supply will
|
|
be shut down automatically. To reset the ocvercurrent protection circuit
|
|
write 1 into wtWebioEA2x2DiagErrorClear.
|
|
Internal power supply is a feature of 57638 only.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Power Supply enable"
|
|
::= { wtWebioEA2x2ERP-24VOutputMode 4 }
|
|
|
|
-- wtWebioEA2x2ERP-24VAlarm Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERP-24VAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebioEA2x2ERP-24VAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebioEA2x2ERP-24VAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebioEA2x2ERP-24VAlarm 2 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebioEA2x2ERP-24VAlarmNo }
|
|
::= { wtWebioEA2x2ERP-24VAlarmIfTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VAlarmIfEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VAlarmNo INTEGER
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtWebioEA2x2ERP-24VAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebioEA2x2ERP-24VAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebioEA2x2ERP-24VAlarm 3 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebioEA2x2ERP-24VAlarmNo }
|
|
::= { wtWebioEA2x2ERP-24VAlarmTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VAlarmEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VAlarmInputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmOutputTrigger OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmSystemTrigger OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmMaxCounterValue OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmInterval OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmEnable OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmMailAddr OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmMailSubject OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmMailText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmSnmpManagerIP OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmSnmpTrapText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmUdpIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmUdpPort INTEGER,
|
|
wtWebioEA2x2ERP-24VAlarmUdpText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmTcpIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmTcpPort INTEGER,
|
|
wtWebioEA2x2ERP-24VAlarmTcpText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmSyslogIpAddr OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmSyslogPort INTEGER,
|
|
wtWebioEA2x2ERP-24VAlarmSyslogText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmFtpDataPort OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmFtpFileName OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmFtpText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmFtpOption OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmTimerCron OCTET STRING,
|
|
|
|
wtWebioEA2x2ERP-24VAlarmMailReleaseSubject OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmMailReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmUdpReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmTcpReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmSyslogReleaseText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VAlarmFtpReleaseText OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VAlarmInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital inputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the inputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital inputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Inputs masked with the any bit trigger with any change
|
|
of the corresponding input bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital inputs 0-1"
|
|
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 1 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmOutputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 contain the ANY bit (1=ON, 0=OFF). Outputs masked with the any bit trigger with any change
|
|
of the corresponding output bit. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: ANY bits of digital outputs 0-1"
|
|
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 2 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmSystemTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4,
|
|
Bit 4-7: unused
|
|
Bit 3 : Warm Start
|
|
Bit 2 : Cold Start
|
|
Bit 1 : Timer
|
|
Bit 0 : Load Control"
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 3 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmMaxCounterValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable configures a max. counter value. If an input counter value
|
|
exceeds this max. value, the corresponding alarm is triggered. Input counters with
|
|
its mask bit unset in wtWebioEA2x2ERP-24VAlarmInputTrigger are not considered."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 4 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 5 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 6 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 7 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 8 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 9 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 10 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 11 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 12 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 13 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 14 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 15 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 16 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 17 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 18 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 19 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 20 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 21 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 22 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 23 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 24 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 25 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 26 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 27 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 28 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 29 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 30 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 31 }
|
|
|
|
wtWebioEA2x2ERP-24VAlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebioEA2x2ERP-24VAlarmEntry 32 }
|
|
|
|
-- wtWebioEA2x2ERP-24VLoadControl
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERP-24VLoadControlView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of automatic load control can be read. All output were tested in
|
|
pairs (0-1). If an error occours at one output,
|
|
both output of an pair will be switched of. For a properly function of the load control
|
|
each output of a pair have to has a load. If there is no existing load, a pull down resistor
|
|
can be used.
|
|
Outputs with no load are automaticly detected and not part of the control function.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0-1: outputs 0-1."
|
|
::= { wtWebioEA2x2ERP-24VAlarm 4 }
|
|
|
|
wtWebioEA2x2ERP-24VLCShutDownView OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Here the result of the automatic load control shut down can be read. All outputs remain switched of,
|
|
until a zero is written into this variable. But previously all loads should be inspected.
|
|
High current (short circuit), a broken supply line or a defect load (i.e. lamp) may be a shut down reason.
|
|
If no load is detected, the load control unit suspend automaticly the control of the corresponding output pair.
|
|
All controlled output could be identified reading the variable wtWebioEA2x2ERP-24VLoadControlEnable.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an ouput.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4: Bit 0-1: outputs 0-1."
|
|
::= { wtWebioEA2x2ERP-24VAlarm 5 }
|
|
|
|
-- wtWebioEA2x2ERP-24VPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtWebioEA2x2ERP-24VInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtWebioEA2x2ERP-24VPorts 1 }
|
|
|
|
wtWebioEA2x2ERP-24VInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtWebioEA2x2ERP-24VInputNo }
|
|
::= { wtWebioEA2x2ERP-24VInputPortTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VInputPortEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VPortInputName OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortInputText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortInputMode OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortInputFilter INTEGER,
|
|
wtWebioEA2x2ERP-24VPortInputBicountPulsePolarity OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortInputBicountInactivTimeout INTEGER
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtWebioEA2x2ERP-24VInputPortEntry 1 }
|
|
|
|
wtWebioEA2x2ERP-24VPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtWebioEA2x2ERP-24VInputPortEntry 2 }
|
|
|
|
wtWebioEA2x2ERP-24VPortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded modes:
|
|
Selecting short pulse detection enable by setting the corresponding bit to 1 enables
|
|
interrupt support for counting. Only positive edges are accepted as trigger
|
|
source. The maximum counting frequenz equals 2000 Hz.
|
|
This mode is available for inputs 0-3 only.
|
|
Selecting counter clear on read by setting the corresponding bit to 1 enables
|
|
the corresponding counter to be cleared automatically every time it is read,
|
|
except HTTP reading with user rights.
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
Selection for input 0-1:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Bidirectional counter enable
|
|
Bit 2 : Counter clear on read
|
|
Bit 1 : Change detection enable (default)
|
|
Bit 0 : Short Pulse detection enable"
|
|
::= { wtWebioEA2x2ERP-24VInputPortEntry 3 }
|
|
|
|
wtWebioEA2x2ERP-24VPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtWebioEA2x2ERP-24VInputPortEntry 4 }
|
|
|
|
wtWebioEA2x2ERP-24VPortInputBicountPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the input pulse.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2ERP-24VInputPortEntry 5 }
|
|
|
|
wtWebioEA2x2ERP-24VPortInputBicountInactivTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse chains with a duration shorter than here specified (in 1/10 sek),
|
|
are ignored."
|
|
::= { wtWebioEA2x2ERP-24VInputPortEntry 6 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtWebioEA2x2ERP-24VOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebioEA2x2ERP-24VOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtWebioEA2x2ERP-24VPorts 2 }
|
|
|
|
wtWebioEA2x2ERP-24VOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtWebioEA2x2ERP-24VOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtWebioEA2x2ERP-24VOutputNo }
|
|
::= { wtWebioEA2x2ERP-24VOutputPortTable 1 }
|
|
|
|
WtWebioEA2x2ERP-24VOutputPortEntry ::= SEQUENCE {
|
|
wtWebioEA2x2ERP-24VPortOutputName OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortOutputText OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortOutputGroupMode OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortOutputSafetyState OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortLogicInputMask OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortLogicInputInverter OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortLogicFunction OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortLogicOutputInverter OCTET STRING,
|
|
wtWebioEA2x2ERP-24VPortPulseDuration INTEGER,
|
|
wtWebioEA2x2ERP-24VPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebioEA2x2ERP-24VPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 1 }
|
|
|
|
wtWebioEA2x2ERP-24VPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 2 }
|
|
|
|
wtWebioEA2x2ERP-24VPortOutputGroupMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"It is possible to connect outputs together to increase the output current.
|
|
This could be done by connecting 2 or 4 outputs in a group together. All bits
|
|
of such a group has to be set all together in the same way. This variable
|
|
configures this group scheme. If one ouput bit of a group is set, all other
|
|
output bits of the same group will be set in the same manner.
|
|
More than one configuration must not be selected.
|
|
Selection for ouputs 0-1:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
OCTET 4: Bit 0 : ouputs 0,1 disconnected (default)
|
|
Bit 1 : ouputs 0+1 connected"
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 3 }
|
|
|
|
wtWebioEA2x2ERP-24VPortOutputSafetyState OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Mask for digital output
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs to be changed
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 1-7: unused
|
|
Bit 0 : Level of digital output"
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 4 }
|
|
|
|
wtWebioEA2x2ERP-24VPortLogicInputMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selecting one of these inputs by setting the corresponding bit to 1
|
|
enables the logic function for the output identified by the index within
|
|
this table. The calculation take place in 4 steps:
|
|
1. Selecting inputs (wtWebioEA2x2ERP-24VPortLogicInputMask)
|
|
2. Inverting inputs if necessary (wtWebioEA2x2ERP-24VPortLogicInputInverter)
|
|
3. Logical combination (wtWebioEA2x2ERP-24VPortLogicFunction)
|
|
4. Inverting the result if necessary (wtWebioEA2x2ERP-24VPortLogicOutputInverter)
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 5 }
|
|
|
|
wtWebioEA2x2ERP-24VPortLogicInputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every input bit selected here will be inverted.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 0-1 : inputs 0-1"
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 6 }
|
|
|
|
wtWebioEA2x2ERP-24VPortLogicFunction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This determines the logic function. No more than one function
|
|
may be selected.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : logic function OR (default)
|
|
Bit 1 : logic function AND
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 7 }
|
|
|
|
wtWebioEA2x2ERP-24VPortLogicOutputInverter OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The logical operation result could be inverteted by setting the corresponding
|
|
bit to 1.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : Output Inverter enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 8 }
|
|
|
|
wtWebioEA2x2ERP-24VPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 9 }
|
|
|
|
wtWebioEA2x2ERP-24VPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtWebioEA2x2ERP-24VPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtWebioEA2x2ERP-24VOutputPortEntry 10 }
|
|
|
|
-- wtWebioEA2x2ERP-24VManufact Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERP-24VMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebioEA2x2ERP-24VManufact 1 }
|
|
|
|
wtWebioEA2x2ERP-24VMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebioEA2x2ERP-24VManufact 2 }
|
|
|
|
wtWebioEA2x2ERP-24VMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebioEA2x2ERP-24VManufact 3 }
|
|
|
|
wtWebioEA2x2ERP-24VMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebioEA2x2ERP-24VManufact 4 }
|
|
|
|
wtWebioEA2x2ERP-24VMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebioEA2x2ERP-24VManufact 5 }
|
|
|
|
-- wtWebioEA2x2ERP-24VDiag Group
|
|
----------------------------
|
|
|
|
wtWebioEA2x2ERP-24VDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebioEA2x2ERP-24VDiag 1 }
|
|
|
|
wtWebioEA2x2ERP-24VDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebioEA2x2ERP-24VDiag 2 }
|
|
|
|
wtWebioEA2x2ERP-24VDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebioEA2x2ERP-24VDiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebioEA2x2ERP-24VDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebioEA2x2ERP-24VDiagErrorMessage."
|
|
::= { wtWebioEA2x2ERP-24VDiag 3 }
|
|
|
|
wtWebioEA2x2ERP-24VDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebioEA2x2ERP-24VDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebioEA2x2ERP-24VDiag 4 }
|
|
|
|
wtWebioEA2x2ERP-24VDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebioEA2x2ERP-24VDiag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebioEA2x2ERP-24VAlert1 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtWebioEA2x2ERP-24VAlert2 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtWebioEA2x2ERP-24VAlert3 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtWebioEA2x2ERP-24VAlert4 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtWebioEA2x2ERP-24VAlert5 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtWebioEA2x2ERP-24VAlert6 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtWebioEA2x2ERP-24VAlert7 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtWebioEA2x2ERP-24VAlert8 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtWebioEA2x2ERP-24VAlert9 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtWebioEA2x2ERP-24VAlert10 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtWebioEA2x2ERP-24VAlert11 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtWebioEA2x2ERP-24VAlert12 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtWebioEA2x2ERP-24VAlert13 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtWebioEA2x2ERP-24VAlert14 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtWebioEA2x2ERP-24VAlert15 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtWebioEA2x2ERP-24VAlert16 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtWebioEA2x2ERP-24VAlert17 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtWebioEA2x2ERP-24VAlert18 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtWebioEA2x2ERP-24VAlert19 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtWebioEA2x2ERP-24VAlert20 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtWebioEA2x2ERP-24VAlert21 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtWebioEA2x2ERP-24VAlert22 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtWebioEA2x2ERP-24VAlert23 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtWebioEA2x2ERP-24VAlert24 TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES { wtWebioEA2x2ERP-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtWebioEA2x2ERP-24VAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebioEA2x2ERP-24V
|
|
VARIABLES {
|
|
wtWebioEA2x2ERP-24VDiagErrorIndex,
|
|
wtWebioEA2x2ERP-24VDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Webio Digital Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtIpWatcher-24VInOut Group
|
|
------------------------
|
|
|
|
wtIpWatcher-24VInputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtIpWatcher-24VInOut 1 }
|
|
|
|
wtIpWatcher-24VOutputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtIpWatcher-24VInOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtIpWatcher-24VInputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtIpWatcher-24VInOut 3 }
|
|
|
|
wtIpWatcher-24VInputEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VInputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtIpWatcher-24VInputNo }
|
|
::= { wtIpWatcher-24VInputTable 1 }
|
|
|
|
WtIpWatcher-24VInputEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VInputNo INTEGER,
|
|
wtIpWatcher-24VInputCounter INTEGER,
|
|
wtIpWatcher-24VInputCounterClear INTEGER,
|
|
wtIpWatcher-24VInputState INTEGER
|
|
|
|
}
|
|
|
|
wtIpWatcher-24VInputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtIpWatcher-24VInputEntry 1 }
|
|
|
|
wtIpWatcher-24VInputCounter OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of the input counter."
|
|
::= { wtIpWatcher-24VInputEntry 2 }
|
|
|
|
wtIpWatcher-24VInputCounterClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clears the input counter after returning its value."
|
|
::= { wtIpWatcher-24VInputEntry 3 }
|
|
|
|
wtIpWatcher-24VInputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtIpWatcher-24VInputEntry 4 }
|
|
|
|
wtIpWatcher-24VInputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtIpWatcher-24VInOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtIpWatcher-24VOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtIpWatcher-24VInOut 5 }
|
|
|
|
wtIpWatcher-24VOutputEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtIpWatcher-24VOutputNo }
|
|
::= { wtIpWatcher-24VOutputTable 1 }
|
|
|
|
WtIpWatcher-24VOutputEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VOutputNo INTEGER,
|
|
wtIpWatcher-24VOutputState INTEGER
|
|
}
|
|
|
|
wtIpWatcher-24VOutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtIpWatcher-24VOutputEntry 1 }
|
|
|
|
wtIpWatcher-24VOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtIpWatcher-24VOutputEntry 2 }
|
|
|
|
|
|
wtIpWatcher-24VOutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read and write the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtIpWatcher-24VInOut 6 }
|
|
|
|
wtIpWatcher-24VSetOutput OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
ACCESS read-write -- write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual digital outputs. The OCTETS are
|
|
interpreted bit-by-bit, with each bit corresponding to an output. Bit 0 corresponds
|
|
to the LSB.
|
|
The first two OCTETS contain the mask which determines which of the outputs are to
|
|
be set (corresponding bit = 1) and which outputs are to remain unchanged
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1"
|
|
::= { wtIpWatcher-24VInOut 7 }
|
|
|
|
-- Alarm Output Interface Table
|
|
|
|
wtIpWatcher-24VAlarmOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VAlarmOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices.."
|
|
::= { wtIpWatcher-24VInOut 8 }
|
|
|
|
wtIpWatcher-24VAlarmOutputEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VAlarmOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index reference."
|
|
INDEX { wtIpWatcher-24VAlarmNo }
|
|
::= { wtIpWatcher-24VAlarmOutputTable 1 }
|
|
|
|
WtIpWatcher-24VAlarmOutputEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VAlarmOutputState INTEGER,
|
|
wtIpWatcher-24VAlarmTriggerState INTEGER
|
|
}
|
|
|
|
wtIpWatcher-24VAlarmOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the alarm, 0-OFF, 1-ON."
|
|
::= { wtIpWatcher-24VAlarmOutputEntry 1 }
|
|
|
|
wtIpWatcher-24VAlarmTriggerState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the trigger condition, 0-OFF, 1-ON."
|
|
::= { wtIpWatcher-24VAlarmOutputEntry 2 }
|
|
|
|
-- wtIpWatcher-24VSessCntrl Group
|
|
--------------------------------
|
|
|
|
wtIpWatcher-24VSessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtIpWatcher-24VSessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtIpWatcher-24VSessCntrl 1 }
|
|
|
|
wtIpWatcher-24VSessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtIpWatcher-24VSessCntrl 2 }
|
|
|
|
wtIpWatcher-24VSessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtIpWatcher-24VSessCntrl 3 }
|
|
|
|
wtIpWatcher-24VSessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtIpWatcher-24VSessCntrl 4 }
|
|
|
|
wtIpWatcher-24VSessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtIpWatcher-24VSessCntrl 5 }
|
|
|
|
-- wtIpWatcher-24VText Group
|
|
------------------------
|
|
|
|
wtIpWatcher-24VDeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtIpWatcher-24VText 1 }
|
|
|
|
wtIpWatcher-24VDeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtIpWatcher-24VText 2 }
|
|
|
|
wtIpWatcher-24VDeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtIpWatcher-24VText 3 }
|
|
|
|
wtIpWatcher-24VDeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtIpWatcher-24VText 4 }
|
|
|
|
-- wtIpWatcher-24VTimeZone Group
|
|
----------------------------
|
|
|
|
wtIpWatcher-24VTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtIpWatcher-24VTimeZone 1 }
|
|
|
|
wtIpWatcher-24VTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtIpWatcher-24VTimeZone 2 }
|
|
|
|
wtIpWatcher-24VTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtIpWatcher-24VTimeZone 3 }
|
|
|
|
wtIpWatcher-24VStTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtIpWatcher-24VTimeZone 4 }
|
|
|
|
wtIpWatcher-24VStTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtIpWatcher-24VTimeZone 5 }
|
|
|
|
wtIpWatcher-24VStTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtIpWatcher-24VTimeZone 6 }
|
|
|
|
wtIpWatcher-24VStTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcher-24VStartMonth-January(1),
|
|
wtIpWatcher-24VStartMonth-February(2),
|
|
wtIpWatcher-24VStartMonth-March(3),
|
|
wtIpWatcher-24VStartMonth-April(4),
|
|
wtIpWatcher-24VStartMonth-May(5),
|
|
wtIpWatcher-24VStartMonth-June(6),
|
|
wtIpWatcher-24VStartMonth-July(7),
|
|
wtIpWatcher-24VStartMonth-August(8),
|
|
wtIpWatcher-24VStartMonth-September(9),
|
|
wtIpWatcher-24VStartMonth-October(10),
|
|
wtIpWatcher-24VStartMonth-November(11),
|
|
wtIpWatcher-24VStartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtIpWatcher-24VTimeZone 7 }
|
|
|
|
wtIpWatcher-24VStTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcher-24VStartMode-first(1),
|
|
wtIpWatcher-24VStartMode-second(2),
|
|
wtIpWatcher-24VStartMode-third(3),
|
|
wtIpWatcher-24VStartMode-fourth(4),
|
|
wtIpWatcher-24VStartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtIpWatcher-24VTimeZone 8 }
|
|
|
|
wtIpWatcher-24VStTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcher-24VStartWday-Sunday(1),
|
|
wtIpWatcher-24VStartWday-Monday(2),
|
|
wtIpWatcher-24VStartWday-Tuesday(3),
|
|
wtIpWatcher-24VStartWday-Thursday(4),
|
|
wtIpWatcher-24VStartWday-Wednesday(5),
|
|
wtIpWatcher-24VStartWday-Friday(6),
|
|
wtIpWatcher-24VStartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtIpWatcher-24VTimeZone 9 }
|
|
|
|
wtIpWatcher-24VStTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtIpWatcher-24VTimeZone 10 }
|
|
|
|
wtIpWatcher-24VStTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtIpWatcher-24VTimeZone 11 }
|
|
|
|
wtIpWatcher-24VStTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcher-24VStopMonth-January(1),
|
|
wtIpWatcher-24VStopMonth-February(2),
|
|
wtIpWatcher-24VStopMonth-March(3),
|
|
wtIpWatcher-24VStopMonth-April(4),
|
|
wtIpWatcher-24VStopMonth-May(5),
|
|
wtIpWatcher-24VStopMonth-June(6),
|
|
wtIpWatcher-24VStopMonth-July(7),
|
|
wtIpWatcher-24VStopMonth-August(8),
|
|
wtIpWatcher-24VStopMonth-September(9),
|
|
wtIpWatcher-24VStopMonth-October(10),
|
|
wtIpWatcher-24VStopMonth-November(11),
|
|
wtIpWatcher-24VStopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtIpWatcher-24VTimeZone 12 }
|
|
|
|
wtIpWatcher-24VStTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcher-24VStopMode-first(1),
|
|
wtIpWatcher-24VStopMode-second(2),
|
|
wtIpWatcher-24VStopMode-third(3),
|
|
wtIpWatcher-24VStopMode-fourth(4),
|
|
wtIpWatcher-24VStopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtIpWatcher-24VTimeZone 13 }
|
|
|
|
wtIpWatcher-24VStTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcher-24VStopWday-Sunday(1),
|
|
wtIpWatcher-24VStopWday-Monday(2),
|
|
wtIpWatcher-24VStopWday-Tuesday(3),
|
|
wtIpWatcher-24VStopWday-Thursday(4),
|
|
wtIpWatcher-24VStopWday-Wednesday(5),
|
|
wtIpWatcher-24VStopWday-Friday(6),
|
|
wtIpWatcher-24VStopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtIpWatcher-24VTimeZone 14 }
|
|
|
|
wtIpWatcher-24VStTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtIpWatcher-24VTimeZone 15 }
|
|
|
|
wtIpWatcher-24VStTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtIpWatcher-24VTimeZone 16 }
|
|
|
|
-- wtIpWatcher-24VTimeServer Group
|
|
----------------------------
|
|
|
|
wtIpWatcher-24VTimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtIpWatcher-24VTimeServer 1 }
|
|
|
|
wtIpWatcher-24VTimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtIpWatcher-24VTimeServer 2 }
|
|
|
|
wtIpWatcher-24VTsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtIpWatcher-24VTimeServer 3 }
|
|
|
|
wtIpWatcher-24VTsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtIpWatcher-24VTimeServer 4 }
|
|
|
|
|
|
-- wtIpWatcher-24VDeviceClock Group
|
|
----------------------------
|
|
|
|
wtIpWatcher-24VClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtIpWatcher-24VDeviceClock 1 }
|
|
|
|
wtIpWatcher-24VClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtIpWatcher-24VDeviceClock 2 }
|
|
|
|
wtIpWatcher-24VClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtIpWatcher-24VDeviceClock 3 }
|
|
|
|
wtIpWatcher-24VClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtIpWatcher-24VClockMonth-January(1),
|
|
wtIpWatcher-24VClockMonth-February(2),
|
|
wtIpWatcher-24VClockMonth-March(3),
|
|
wtIpWatcher-24VClockMonth-April(4),
|
|
wtIpWatcher-24VClockMonth-May(5),
|
|
wtIpWatcher-24VClockMonth-June(6),
|
|
wtIpWatcher-24VClockMonth-July(7),
|
|
wtIpWatcher-24VClockMonth-August(8),
|
|
wtIpWatcher-24VClockMonth-September(9),
|
|
wtIpWatcher-24VClockMonth-October(10),
|
|
wtIpWatcher-24VClockMonth-November(11),
|
|
wtIpWatcher-24VClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtIpWatcher-24VDeviceClock 4 }
|
|
|
|
wtIpWatcher-24VClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtIpWatcher-24VDeviceClock 5 }
|
|
|
|
-- wtIpWatcher-24VNetwork Group
|
|
------------------------
|
|
|
|
wtIpWatcher-24VIpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtIpWatcher-24VNetwork 1 }
|
|
|
|
wtIpWatcher-24VSubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtIpWatcher-24VNetwork 2 }
|
|
|
|
wtIpWatcher-24VGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtIpWatcher-24VNetwork 3 }
|
|
|
|
wtIpWatcher-24VDnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtIpWatcher-24VNetwork 4 }
|
|
|
|
wtIpWatcher-24VDnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtIpWatcher-24VNetwork 5 }
|
|
|
|
wtIpWatcher-24VAddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtIpWatcher-24VNetwork 6 }
|
|
|
|
-- wtIpWatcher-24VHTTP Group
|
|
--------------------------------
|
|
|
|
wtIpWatcher-24VHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtIpWatcher-24VHTTP 4 }
|
|
|
|
|
|
-- wtIpWatcher-24VMail Group
|
|
--------------------------------
|
|
|
|
wtIpWatcher-24VMailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtIpWatcher-24VMail 1 }
|
|
|
|
wtIpWatcher-24VMailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtIpWatcher-24VMail 2 }
|
|
|
|
wtIpWatcher-24VMailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtIpWatcher-24VMail 3 }
|
|
|
|
wtIpWatcher-24VMailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtIpWatcher-24VMail 4 }
|
|
|
|
wtIpWatcher-24VMailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtIpWatcher-24VMail 5 }
|
|
|
|
wtIpWatcher-24VMailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtIpWatcher-24VMail 6 }
|
|
|
|
wtIpWatcher-24VMailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtIpWatcher-24VMail 7 }
|
|
|
|
wtIpWatcher-24VMailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtIpWatcher-24VMail 8 }
|
|
|
|
|
|
-- wtIpWatcher-24VSnmp Group
|
|
--------------------------------
|
|
|
|
wtIpWatcher-24VSnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtIpWatcher-24VSNMP 1 }
|
|
|
|
wtIpWatcher-24VSnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtIpWatcher-24VSNMP 2 }
|
|
|
|
wtIpWatcher-24VSnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtIpWatcher-24VSNMP 3 }
|
|
|
|
wtIpWatcher-24VSnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtIpWatcher-24VSNMP 4 }
|
|
|
|
wtIpWatcher-24VSnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtIpWatcher-24VSNMP 5 }
|
|
|
|
-- wtIpWatcher-24VUDP Group
|
|
--------------------------------
|
|
|
|
wtIpWatcher-24VUdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtIpWatcher-24VUDP 1 }
|
|
|
|
wtIpWatcher-24VUdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtIpWatcher-24VUDP 2 }
|
|
|
|
wtIpWatcher-24VUdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtIpWatcher-24VUDP 3 }
|
|
|
|
-- wtIpWatcher-24VSyslog Group
|
|
--------------------------------
|
|
|
|
wtIpWatcher-24VSyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtIpWatcher-24VSyslog 1 }
|
|
|
|
wtIpWatcher-24VSyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtIpWatcher-24VSyslog 2 }
|
|
|
|
wtIpWatcher-24VSyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtIpWatcher-24VSyslog 3 }
|
|
|
|
wtIpWatcher-24VSyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtIpWatcher-24VSyslog 4 }
|
|
|
|
-- wtIpWatcher-24VFTP Group
|
|
--------------------------------
|
|
|
|
wtIpWatcher-24VFTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtIpWatcher-24VFTP 1 }
|
|
|
|
wtIpWatcher-24VFTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtIpWatcher-24VFTP 2 }
|
|
|
|
wtIpWatcher-24VFTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtIpWatcher-24VFTP 3 }
|
|
|
|
wtIpWatcher-24VFTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtIpWatcher-24VFTP 4 }
|
|
|
|
wtIpWatcher-24VFTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtIpWatcher-24VFTP 5 }
|
|
|
|
wtIpWatcher-24VFTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtIpWatcher-24VFTP 6 }
|
|
|
|
wtIpWatcher-24VFTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtIpWatcher-24VFTP 7 }
|
|
|
|
-- wtIpWatcher-24VIpList Group
|
|
----------------------------
|
|
|
|
wtIpWatcher-24VIpListCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Ip addresses."
|
|
::= { wtIpWatcher-24VIpList 1 }
|
|
|
|
-- IpList Interface Table
|
|
|
|
wtIpWatcher-24VIpListIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VIpListIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of inices."
|
|
::= { wtIpWatcher-24VIpList 2 }
|
|
|
|
wtIpWatcher-24VIpListIfEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VIpListIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table entry."
|
|
INDEX { wtIpWatcher-24VIpListNo }
|
|
::= { wtIpWatcher-24VIpListIfTable 1 }
|
|
|
|
WtIpWatcher-24VIpListIfEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VIpListNo INTEGER
|
|
}
|
|
|
|
wtIpWatcher-24VIpListNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..999)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List number of this entry."
|
|
::= { wtIpWatcher-24VIpListIfEntry 1 }
|
|
|
|
-- IpList Table
|
|
|
|
wtIpWatcher-24VIpListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VIpListEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of ip addresses."
|
|
::= { wtIpWatcher-24VIpList 3 }
|
|
|
|
wtIpWatcher-24VIpListEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VIpListEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List entry."
|
|
INDEX { wtIpWatcher-24VIpListNo }
|
|
::= { wtIpWatcher-24VIpListTable 1 }
|
|
|
|
WtIpWatcher-24VIpListEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VIpListName OCTET STRING,
|
|
wtIpWatcher-24VIpListPort INTEGER,
|
|
wtIpWatcher-24VIpListService OCTET STRING,
|
|
wtIpWatcher-24VIpListEnable OCTET STRING,
|
|
wtIpWatcher-24VIpListAlias OCTET STRING
|
|
}
|
|
|
|
wtIpWatcher-24VIpListName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address."
|
|
::= { wtIpWatcher-24VIpListEntry 1 }
|
|
|
|
wtIpWatcher-24VIpListPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number, zero in the case of broadcast or Ping."
|
|
::= { wtIpWatcher-24VIpListEntry 2 }
|
|
|
|
wtIpWatcher-24VIpListService OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded scan mode, only one mode can be selected at a particular time:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Ping enable
|
|
Bit 1-7: unused"
|
|
::= { wtIpWatcher-24VIpListEntry 3 }
|
|
|
|
wtIpWatcher-24VIpListEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: enabled in Alarm 1
|
|
Bit 1: enabled in Alarm 2
|
|
Bit 2: enabled in Alarm 3
|
|
Bit 3: enabled in Alarm 4
|
|
Bit 4-7: unused"
|
|
::= { wtIpWatcher-24VIpListEntry 4 }
|
|
|
|
wtIpWatcher-24VIpListAlias OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alias Name"
|
|
::= { wtIpWatcher-24VIpListEntry 5 }
|
|
|
|
|
|
-- wtIpWatcher-24VOutputMode Group
|
|
----------------------------
|
|
|
|
wtIpWatcher-24VPowerSupplyEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this enable bit turns on the intarnal 24V power supply of the outputs.
|
|
All currents out must not exceed 150mA. At overcurrent condition the power supply will
|
|
be shut down automatically. To reset the ocvercurrent protection circuit
|
|
write 1 into wtIpWatcher-24VDiagErrorClear.
|
|
Internal power supply is a feature of 57655 only.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Power Supply enable"
|
|
::= { wtIpWatcher-24VOutputMode 4 }
|
|
|
|
|
|
-- wtIpWatcher-24VAlarm Group
|
|
----------------------------
|
|
|
|
wtIpWatcher-24VAlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtIpWatcher-24VAlarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtIpWatcher-24VAlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtIpWatcher-24VAlarm 2 }
|
|
|
|
wtIpWatcher-24VAlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VAlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtIpWatcher-24VAlarmNo }
|
|
::= { wtIpWatcher-24VAlarmIfTable 1 }
|
|
|
|
WtIpWatcher-24VAlarmIfEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VAlarmNo INTEGER
|
|
}
|
|
|
|
wtIpWatcher-24VAlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtIpWatcher-24VAlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtIpWatcher-24VAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtIpWatcher-24VAlarm 3 }
|
|
|
|
wtIpWatcher-24VAlarmEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VAlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtIpWatcher-24VAlarmNo }
|
|
::= { wtIpWatcher-24VAlarmTable 1 }
|
|
|
|
WtIpWatcher-24VAlarmEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VAlarmInterval OCTET STRING,
|
|
wtIpWatcher-24VAlarmEnable OCTET STRING,
|
|
wtIpWatcher-24VAlarmMailAddr OCTET STRING,
|
|
wtIpWatcher-24VAlarmMailSubject OCTET STRING,
|
|
wtIpWatcher-24VAlarmMailText OCTET STRING,
|
|
wtIpWatcher-24VAlarmSnmpManagerIP OCTET STRING,
|
|
wtIpWatcher-24VAlarmSnmpTrapText OCTET STRING,
|
|
wtIpWatcher-24VAlarmUdpIpAddr OCTET STRING,
|
|
wtIpWatcher-24VAlarmUdpPort INTEGER,
|
|
wtIpWatcher-24VAlarmUdpText OCTET STRING,
|
|
wtIpWatcher-24VAlarmTcpIpAddr OCTET STRING,
|
|
wtIpWatcher-24VAlarmTcpPort INTEGER,
|
|
wtIpWatcher-24VAlarmTcpText OCTET STRING,
|
|
wtIpWatcher-24VAlarmSyslogIpAddr OCTET STRING,
|
|
wtIpWatcher-24VAlarmSyslogPort INTEGER,
|
|
wtIpWatcher-24VAlarmSyslogText OCTET STRING,
|
|
wtIpWatcher-24VAlarmFtpDataPort OCTET STRING,
|
|
wtIpWatcher-24VAlarmFtpFileName OCTET STRING,
|
|
wtIpWatcher-24VAlarmFtpText OCTET STRING,
|
|
wtIpWatcher-24VAlarmFtpOption OCTET STRING,
|
|
wtIpWatcher-24VAlarmTimerCron OCTET STRING,
|
|
|
|
wtIpWatcher-24VAlarmMailReleaseSubject OCTET STRING,
|
|
wtIpWatcher-24VAlarmMailReleaseText OCTET STRING,
|
|
wtIpWatcher-24VAlarmSnmpTrapReleaseText OCTET STRING,
|
|
wtIpWatcher-24VAlarmUdpReleaseText OCTET STRING,
|
|
wtIpWatcher-24VAlarmTcpReleaseText OCTET STRING,
|
|
wtIpWatcher-24VAlarmSyslogReleaseText OCTET STRING,
|
|
wtIpWatcher-24VAlarmFtpReleaseText OCTET STRING,
|
|
|
|
wtIpWatcher-24VAlarmName OCTET STRING,
|
|
wtIpWatcher-24VAlarmGlobalEnable OCTET STRING,
|
|
wtIpWatcher-24VAlarmCounterClear OCTET STRING,
|
|
wtIpWatcher-24VAlarmAckEnable OCTET STRING,
|
|
wtIpWatcher-24VAlarmAckPort INTEGER,
|
|
wtIpWatcher-24VAlarmSetPort INTEGER,
|
|
|
|
wtIpWatcher-24VAlarmMailTrgClearSubject OCTET STRING,
|
|
wtIpWatcher-24VAlarmMailTrgClearText OCTET STRING,
|
|
wtIpWatcher-24VAlarmSnmpTrapTrgClearText OCTET STRING,
|
|
wtIpWatcher-24VAlarmUdpTrgClearText OCTET STRING,
|
|
wtIpWatcher-24VAlarmTcpTrgClearText OCTET STRING,
|
|
wtIpWatcher-24VAlarmSyslogTrgClearText OCTET STRING,
|
|
wtIpWatcher-24VAlarmFtpTrgClearText OCTET STRING,
|
|
|
|
wtIpWatcher-24VAlarmMailTrapTxEnable OCTET STRING,
|
|
wtIpWatcher-24VAlarmSnmpTrapTrapTxEnable OCTET STRING,
|
|
wtIpWatcher-24VAlarmUdpTrapTxEnable OCTET STRING,
|
|
wtIpWatcher-24VAlarmTcpTrapTxEnable OCTET STRING,
|
|
wtIpWatcher-24VAlarmSyslogTrapTxEnable OCTET STRING,
|
|
wtIpWatcher-24VAlarmFtpTrapTxEnable OCTET STRING,
|
|
|
|
wtIpWatcher-24VAlarmTriggerCount INTEGER,
|
|
wtIpWatcher-24VAlarmPollingRate INTEGER
|
|
}
|
|
|
|
wtIpWatcher-24VAlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtIpWatcher-24VAlarmEntry 5 }
|
|
|
|
wtIpWatcher-24VAlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtIpWatcher-24VAlarmEntry 6 }
|
|
|
|
wtIpWatcher-24VAlarmMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtIpWatcher-24VAlarmEntry 7 }
|
|
|
|
wtIpWatcher-24VAlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtIpWatcher-24VAlarmEntry 8 }
|
|
|
|
wtIpWatcher-24VAlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtIpWatcher-24VAlarmEntry 9 }
|
|
|
|
wtIpWatcher-24VAlarmSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtIpWatcher-24VAlarmEntry 10 }
|
|
|
|
wtIpWatcher-24VAlarmSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 11 }
|
|
|
|
wtIpWatcher-24VAlarmUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtIpWatcher-24VAlarmEntry 12 }
|
|
|
|
wtIpWatcher-24VAlarmUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtIpWatcher-24VAlarmEntry 13 }
|
|
|
|
wtIpWatcher-24VAlarmUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 14 }
|
|
|
|
wtIpWatcher-24VAlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtIpWatcher-24VAlarmEntry 15 }
|
|
|
|
wtIpWatcher-24VAlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtIpWatcher-24VAlarmEntry 16 }
|
|
|
|
wtIpWatcher-24VAlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 17 }
|
|
|
|
wtIpWatcher-24VAlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtIpWatcher-24VAlarmEntry 18 }
|
|
|
|
wtIpWatcher-24VAlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtIpWatcher-24VAlarmEntry 19 }
|
|
|
|
wtIpWatcher-24VAlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtIpWatcher-24VAlarmEntry 20 }
|
|
|
|
wtIpWatcher-24VAlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtIpWatcher-24VAlarmEntry 21 }
|
|
|
|
wtIpWatcher-24VAlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtIpWatcher-24VAlarmEntry 22 }
|
|
|
|
wtIpWatcher-24VAlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtIpWatcher-24VAlarmEntry 23 }
|
|
|
|
wtIpWatcher-24VAlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtIpWatcher-24VAlarmEntry 24 }
|
|
|
|
wtIpWatcher-24VAlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtIpWatcher-24VAlarmEntry 25 }
|
|
|
|
wtIpWatcher-24VAlarmMailReleaseSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtIpWatcher-24VAlarmEntry 26 }
|
|
|
|
wtIpWatcher-24VAlarmMailReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Release Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtIpWatcher-24VAlarmEntry 27 }
|
|
|
|
wtIpWatcher-24VAlarmSnmpTrapReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 28 }
|
|
|
|
wtIpWatcher-24VAlarmUdpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 29 }
|
|
|
|
wtIpWatcher-24VAlarmTcpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 30 }
|
|
|
|
wtIpWatcher-24VAlarmSyslogReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtIpWatcher-24VAlarmEntry 31 }
|
|
|
|
wtIpWatcher-24VAlarmFtpReleaseText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtIpWatcher-24VAlarmEntry 32 }
|
|
|
|
wtIpWatcher-24VAlarmName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the alarm."
|
|
::= { wtIpWatcher-24VAlarmEntry 33 }
|
|
|
|
wtIpWatcher-24VAlarmGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
Die OCTETS werden bitweise interpretiert.
|
|
Bit 0 entspricht dem LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Alarm enable"
|
|
::= { wtIpWatcher-24VAlarmEntry 34 }
|
|
|
|
wtIpWatcher-24VAlarmCounterClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Counter clear on Alarm acknowledge
|
|
Bit 0 : Counter clear on Alarm send"
|
|
::= { wtIpWatcher-24VAlarmEntry 35 }
|
|
|
|
|
|
wtIpWatcher-24VAlarmAckEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : Software acknowledge enable
|
|
Bit 0 : Hardware acknowledge enable"
|
|
::= { wtIpWatcher-24VAlarmEntry 36 }
|
|
|
|
|
|
wtIpWatcher-24VAlarmAckPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the input, which clears the alarm (1-6)."
|
|
::= { wtIpWatcher-24VAlarmEntry 37 }
|
|
|
|
wtIpWatcher-24VAlarmSetPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the output, which will be set by this alarm (1-6).
|
|
The configuration of pulse mode and polarity defined in the port output section is used."
|
|
::= { wtIpWatcher-24VAlarmEntry 38 }
|
|
|
|
wtIpWatcher-24VAlarmMailTrgClearSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtIpWatcher-24VAlarmEntry 39 }
|
|
|
|
wtIpWatcher-24VAlarmMailTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtIpWatcher-24VAlarmEntry 40 }
|
|
|
|
wtIpWatcher-24VAlarmSnmpTrapTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 41 }
|
|
|
|
wtIpWatcher-24VAlarmUdpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 42 }
|
|
|
|
wtIpWatcher-24VAlarmTcpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtIpWatcher-24VAlarmEntry 43 }
|
|
|
|
wtIpWatcher-24VAlarmSyslogTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtIpWatcher-24VAlarmEntry 44 }
|
|
|
|
wtIpWatcher-24VAlarmFtpTrgClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtIpWatcher-24VAlarmEntry 45 }
|
|
|
|
wtIpWatcher-24VAlarmMailTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcher-24VAlarmEntry 46 }
|
|
|
|
wtIpWatcher-24VAlarmSnmpTrapTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcher-24VAlarmEntry 47 }
|
|
|
|
wtIpWatcher-24VAlarmUdpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcher-24VAlarmEntry 48 }
|
|
|
|
wtIpWatcher-24VAlarmTcpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcher-24VAlarmEntry 49 }
|
|
|
|
wtIpWatcher-24VAlarmSyslogTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcher-24VAlarmEntry 50 }
|
|
|
|
wtIpWatcher-24VAlarmFtpTrapTxEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
The OCTETS are interpreted bit-by-bit.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 4-7: unused
|
|
Bit 3 : Alarm OFF message enable
|
|
Bit 2 : Trigger OFF message enable
|
|
Bit 1 : Re-Trigger message enable
|
|
Bit 0 : Alarm ON message enable"
|
|
::= { wtIpWatcher-24VAlarmEntry 51 }
|
|
|
|
wtIpWatcher-24VAlarmTriggerCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm will be send if the trigger condition occours TriggerCount times."
|
|
::= { wtIpWatcher-24VAlarmEntry 52 }
|
|
|
|
wtIpWatcher-24VAlarmPollingRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time in seconds."
|
|
::= { wtIpWatcher-24VAlarmEntry 53 }
|
|
|
|
-- wtIpWatcher-24VPorts Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
wtIpWatcher-24VInputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtIpWatcher-24VPorts 1 }
|
|
|
|
wtIpWatcher-24VInputPortEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VInputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtIpWatcher-24VInputNo }
|
|
::= { wtIpWatcher-24VInputPortTable 1 }
|
|
|
|
WtIpWatcher-24VInputPortEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VPortInputName OCTET STRING,
|
|
wtIpWatcher-24VPortInputText OCTET STRING,
|
|
wtIpWatcher-24VPortInputFilter INTEGER
|
|
}
|
|
|
|
wtIpWatcher-24VPortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtIpWatcher-24VInputPortEntry 1 }
|
|
|
|
wtIpWatcher-24VPortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtIpWatcher-24VInputPortEntry 2 }
|
|
|
|
wtIpWatcher-24VPortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtIpWatcher-24VInputPortEntry 4 }
|
|
|
|
-- Output Port Table
|
|
|
|
wtIpWatcher-24VOutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtIpWatcher-24VOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtIpWatcher-24VPorts 2 }
|
|
|
|
wtIpWatcher-24VOutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtIpWatcher-24VOutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtIpWatcher-24VOutputNo }
|
|
::= { wtIpWatcher-24VOutputPortTable 1 }
|
|
|
|
WtIpWatcher-24VOutputPortEntry ::= SEQUENCE {
|
|
wtIpWatcher-24VPortOutputName OCTET STRING,
|
|
wtIpWatcher-24VPortOutputText OCTET STRING,
|
|
wtIpWatcher-24VPortPulseDuration INTEGER,
|
|
wtIpWatcher-24VPortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtIpWatcher-24VPortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtIpWatcher-24VOutputPortEntry 1 }
|
|
|
|
wtIpWatcher-24VPortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtIpWatcher-24VOutputPortEntry 2 }
|
|
|
|
wtIpWatcher-24VPortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtIpWatcher-24VOutputPortEntry 9 }
|
|
|
|
wtIpWatcher-24VPortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtIpWatcher-24VPortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtIpWatcher-24VOutputPortEntry 10 }
|
|
|
|
-- wtIpWatcher-24VManufact Group
|
|
----------------------------
|
|
|
|
wtIpWatcher-24VMfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtIpWatcher-24VManufact 1 }
|
|
|
|
wtIpWatcher-24VMfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtIpWatcher-24VManufact 2 }
|
|
|
|
wtIpWatcher-24VMfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtIpWatcher-24VManufact 3 }
|
|
|
|
wtIpWatcher-24VMfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtIpWatcher-24VManufact 4 }
|
|
|
|
wtIpWatcher-24VMfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtIpWatcher-24VManufact 5 }
|
|
|
|
-- wtIpWatcher-24VDiag Group
|
|
----------------------------
|
|
|
|
wtIpWatcher-24VDiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtIpWatcher-24VDiag 1 }
|
|
|
|
wtIpWatcher-24VDiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtIpWatcher-24VDiag 2 }
|
|
|
|
wtIpWatcher-24VDiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtIpWatcher-24VDiagErrorMessage.
|
|
Errors are numbered from 1 to wtIpWatcher-24VDiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtIpWatcher-24VDiagErrorMessage."
|
|
::= { wtIpWatcher-24VDiag 3 }
|
|
|
|
wtIpWatcher-24VDiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtIpWatcher-24VDiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtIpWatcher-24VDiag 4 }
|
|
|
|
wtIpWatcher-24VDiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtIpWatcher-24VDiag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtIpWatcher-24VAlert1 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtIpWatcher-24VAlert2 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtIpWatcher-24VAlert3 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtIpWatcher-24VAlert4 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtIpWatcher-24VAlert5 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtIpWatcher-24VAlert6 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtIpWatcher-24VAlert7 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtIpWatcher-24VAlert8 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtIpWatcher-24VAlert9 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 9"
|
|
--#SUMMARY "Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtIpWatcher-24VAlert10 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 10"
|
|
--#SUMMARY "Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtIpWatcher-24VAlert11 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 11"
|
|
--#SUMMARY "Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtIpWatcher-24VAlert12 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 12"
|
|
--#SUMMARY "Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
wtIpWatcher-24VAlert13 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 71
|
|
|
|
wtIpWatcher-24VAlert14 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 72
|
|
|
|
wtIpWatcher-24VAlert15 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 73
|
|
|
|
wtIpWatcher-24VAlert16 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 74
|
|
|
|
wtIpWatcher-24VAlert17 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 75
|
|
|
|
wtIpWatcher-24VAlert18 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 76
|
|
|
|
wtIpWatcher-24VAlert19 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 77
|
|
|
|
wtIpWatcher-24VAlert20 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 78
|
|
|
|
wtIpWatcher-24VAlert21 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 79
|
|
|
|
wtIpWatcher-24VAlert22 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 80
|
|
|
|
wtIpWatcher-24VAlert23 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 81
|
|
|
|
wtIpWatcher-24VAlert24 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapReleaseText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Release Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 82
|
|
|
|
wtIpWatcher-24VAlert25 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 1 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 91
|
|
|
|
wtIpWatcher-24VAlert26 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 2 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 92
|
|
|
|
wtIpWatcher-24VAlert27 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 3 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 93
|
|
|
|
wtIpWatcher-24VAlert28 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 4 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 94
|
|
|
|
wtIpWatcher-24VAlert29 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 5 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 95
|
|
|
|
wtIpWatcher-24VAlert30 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 6 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 96
|
|
|
|
wtIpWatcher-24VAlert31 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 7 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 97
|
|
|
|
wtIpWatcher-24VAlert32 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 8 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 98
|
|
|
|
wtIpWatcher-24VAlert33 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 9 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 9"
|
|
--#SUMMARY "Release Alarm 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 99
|
|
|
|
wtIpWatcher-24VAlert34 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 10 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 10"
|
|
--#SUMMARY "Release Alarm 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 100
|
|
|
|
wtIpWatcher-24VAlert35 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 11 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 11"
|
|
--#SUMMARY "Release Alarm 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 101
|
|
|
|
wtIpWatcher-24VAlert36 TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES { wtIpWatcher-24VAlarmSnmpTrapTrgClearText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the trigger of the Alarm 12 was released,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Alarm 12"
|
|
--#SUMMARY "Release Alarm 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 102
|
|
|
|
wtIpWatcher-24VAlertDiag TRAP-TYPE
|
|
ENTERPRISE wtIpWatcher-24V
|
|
VARIABLES {
|
|
wtIpWatcher-24VDiagErrorIndex,
|
|
wtIpWatcher-24VDiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "IP Watcher Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
-- wtTrapReceiver2x2InOut Group
|
|
------------------------
|
|
|
|
wtTrapReceiver2x2Inputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent inputs."
|
|
::= { wtTrapReceiver2x2InOut 1 }
|
|
|
|
wtTrapReceiver2x2Outputs OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of idependent outputs."
|
|
::= { wtTrapReceiver2x2InOut 2 }
|
|
|
|
-- Input Interface Table
|
|
|
|
wtTrapReceiver2x2InputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of input indices."
|
|
::= { wtTrapReceiver2x2InOut 3 }
|
|
|
|
wtTrapReceiver2x2InputEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2InputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the inputs."
|
|
INDEX { wtTrapReceiver2x2InputNo }
|
|
::= { wtTrapReceiver2x2InputTable 1 }
|
|
|
|
WtTrapReceiver2x2InputEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2InputNo INTEGER,
|
|
wtTrapReceiver2x2InputState INTEGER
|
|
|
|
}
|
|
|
|
wtTrapReceiver2x2InputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numbers of the inputs."
|
|
::= { wtTrapReceiver2x2InputEntry 1 }
|
|
|
|
wtTrapReceiver2x2InputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single input bit, 0-OFF, 1-ON."
|
|
::= { wtTrapReceiver2x2InputEntry 4 }
|
|
|
|
wtTrapReceiver2x2InputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the inputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1"
|
|
::= { wtTrapReceiver2x2InOut 4 }
|
|
|
|
|
|
-- Output Interface Table
|
|
|
|
wtTrapReceiver2x2OutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of output indices."
|
|
::= { wtTrapReceiver2x2InOut 5 }
|
|
|
|
wtTrapReceiver2x2OutputEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2OutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the outputs."
|
|
INDEX { wtTrapReceiver2x2OutputNo }
|
|
::= { wtTrapReceiver2x2OutputTable 1 }
|
|
|
|
WtTrapReceiver2x2OutputEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2OutputNo INTEGER,
|
|
wtTrapReceiver2x2OutputState INTEGER
|
|
}
|
|
|
|
wtTrapReceiver2x2OutputNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output number."
|
|
::= { wtTrapReceiver2x2OutputEntry 1 }
|
|
|
|
wtTrapReceiver2x2OutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Value of a single output bit, 0-OFF, 1-ON."
|
|
::= { wtTrapReceiver2x2OutputEntry 2 }
|
|
|
|
|
|
wtTrapReceiver2x2OutputValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable is used to read the outputs of the digital I/O port.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Digital outputs 0-1
|
|
Bit 2-7: ungenutzt"
|
|
::= { wtTrapReceiver2x2InOut 6 }
|
|
|
|
-- Action Output Interface Table
|
|
|
|
wtTrapReceiver2x2ActionOutputTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2ActionOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices.."
|
|
::= { wtTrapReceiver2x2InOut 8 }
|
|
|
|
wtTrapReceiver2x2ActionOutputEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2ActionOutputEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index reference."
|
|
INDEX { wtTrapReceiver2x2ActionNo }
|
|
::= { wtTrapReceiver2x2ActionOutputTable 1 }
|
|
|
|
WtTrapReceiver2x2ActionOutputEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2ActionOutputState INTEGER,
|
|
wtTrapReceiver2x2ActionTriggerState INTEGER
|
|
}
|
|
|
|
wtTrapReceiver2x2ActionOutputState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the alarm, 0-OFF, 1-ON."
|
|
::= { wtTrapReceiver2x2ActionOutputEntry 1 }
|
|
|
|
wtTrapReceiver2x2ActionTriggerState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"State of the trigger condition, 0-OFF, 1-ON."
|
|
::= { wtTrapReceiver2x2ActionOutputEntry 2 }
|
|
|
|
-- SystemTimer Interface Table
|
|
|
|
wtTrapReceiver2x2SystemTimerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2SystemTimerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of system timer."
|
|
::= { wtTrapReceiver2x2InOut 9 }
|
|
|
|
wtTrapReceiver2x2SystemTimerEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2SystemTimerEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the system timer."
|
|
INDEX { wtTrapReceiver2x2SystemTimerNo }
|
|
::= { wtTrapReceiver2x2SystemTimerTable 1 }
|
|
|
|
WtTrapReceiver2x2SystemTimerEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2SystemTimerNo INTEGER
|
|
|
|
}
|
|
|
|
wtTrapReceiver2x2SystemTimerNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index number of the system timer."
|
|
::= { wtTrapReceiver2x2SystemTimerEntry 1 }
|
|
|
|
-- Button Interface Table
|
|
|
|
wtTrapReceiver2x2ButtonTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2ButtonEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of buttons."
|
|
::= { wtTrapReceiver2x2InOut 10 }
|
|
|
|
wtTrapReceiver2x2ButtonEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2ButtonEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the button."
|
|
INDEX { wtTrapReceiver2x2ButtonNo }
|
|
::= { wtTrapReceiver2x2ButtonTable 1 }
|
|
|
|
WtTrapReceiver2x2ButtonEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2ButtonNo INTEGER
|
|
|
|
}
|
|
|
|
wtTrapReceiver2x2ButtonNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Index numder of the button."
|
|
::= { wtTrapReceiver2x2ButtonEntry 1 }
|
|
|
|
|
|
-- wtTrapReceiver2x2SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtTrapReceiver2x2SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtTrapReceiver2x2SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtTrapReceiver2x2SessCntrl 1 }
|
|
|
|
wtTrapReceiver2x2SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the password
|
|
was written, the device is already in config mode and the variables
|
|
can only be read."
|
|
::= { wtTrapReceiver2x2SessCntrl 2 }
|
|
|
|
wtTrapReceiver2x2SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again. When read this variable
|
|
provides the value 0."
|
|
::= { wtTrapReceiver2x2SessCntrl 3 }
|
|
|
|
wtTrapReceiver2x2SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtTrapReceiver2x2SessCntrl 4 }
|
|
|
|
wtTrapReceiver2x2SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtTrapReceiver2x2SessCntrl 5 }
|
|
|
|
-- wtTrapReceiver2x2Text Group
|
|
------------------------
|
|
|
|
wtTrapReceiver2x2DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtTrapReceiver2x2Text 1 }
|
|
|
|
wtTrapReceiver2x2DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtTrapReceiver2x2Text 2 }
|
|
|
|
wtTrapReceiver2x2DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtTrapReceiver2x2Text 3 }
|
|
|
|
wtTrapReceiver2x2DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtTrapReceiver2x2Text 4 }
|
|
|
|
-- wtTrapReceiver2x2TimeZone Group
|
|
----------------------------
|
|
|
|
wtTrapReceiver2x2TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtTrapReceiver2x2TimeZone 1 }
|
|
|
|
wtTrapReceiver2x2TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtTrapReceiver2x2TimeZone 2 }
|
|
|
|
wtTrapReceiver2x2TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtTrapReceiver2x2TimeZone 3 }
|
|
|
|
wtTrapReceiver2x2StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtTrapReceiver2x2TimeZone 4 }
|
|
|
|
wtTrapReceiver2x2StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtTrapReceiver2x2TimeZone 5 }
|
|
|
|
wtTrapReceiver2x2StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtTrapReceiver2x2TimeZone 6 }
|
|
|
|
wtTrapReceiver2x2StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtTrapReceiver2x2StartMonth-January(1),
|
|
wtTrapReceiver2x2StartMonth-February(2),
|
|
wtTrapReceiver2x2StartMonth-March(3),
|
|
wtTrapReceiver2x2StartMonth-April(4),
|
|
wtTrapReceiver2x2StartMonth-May(5),
|
|
wtTrapReceiver2x2StartMonth-June(6),
|
|
wtTrapReceiver2x2StartMonth-July(7),
|
|
wtTrapReceiver2x2StartMonth-August(8),
|
|
wtTrapReceiver2x2StartMonth-September(9),
|
|
wtTrapReceiver2x2StartMonth-October(10),
|
|
wtTrapReceiver2x2StartMonth-November(11),
|
|
wtTrapReceiver2x2StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtTrapReceiver2x2TimeZone 7 }
|
|
|
|
wtTrapReceiver2x2StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtTrapReceiver2x2StartMode-first(1),
|
|
wtTrapReceiver2x2StartMode-second(2),
|
|
wtTrapReceiver2x2StartMode-third(3),
|
|
wtTrapReceiver2x2StartMode-fourth(4),
|
|
wtTrapReceiver2x2StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtTrapReceiver2x2TimeZone 8 }
|
|
|
|
wtTrapReceiver2x2StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtTrapReceiver2x2StartWday-Sunday(1),
|
|
wtTrapReceiver2x2StartWday-Monday(2),
|
|
wtTrapReceiver2x2StartWday-Tuesday(3),
|
|
wtTrapReceiver2x2StartWday-Thursday(4),
|
|
wtTrapReceiver2x2StartWday-Wednesday(5),
|
|
wtTrapReceiver2x2StartWday-Friday(6),
|
|
wtTrapReceiver2x2StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtTrapReceiver2x2TimeZone 9 }
|
|
|
|
wtTrapReceiver2x2StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtTrapReceiver2x2TimeZone 10 }
|
|
|
|
wtTrapReceiver2x2StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtTrapReceiver2x2TimeZone 11 }
|
|
|
|
wtTrapReceiver2x2StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtTrapReceiver2x2StopMonth-January(1),
|
|
wtTrapReceiver2x2StopMonth-February(2),
|
|
wtTrapReceiver2x2StopMonth-March(3),
|
|
wtTrapReceiver2x2StopMonth-April(4),
|
|
wtTrapReceiver2x2StopMonth-May(5),
|
|
wtTrapReceiver2x2StopMonth-June(6),
|
|
wtTrapReceiver2x2StopMonth-July(7),
|
|
wtTrapReceiver2x2StopMonth-August(8),
|
|
wtTrapReceiver2x2StopMonth-September(9),
|
|
wtTrapReceiver2x2StopMonth-October(10),
|
|
wtTrapReceiver2x2StopMonth-November(11),
|
|
wtTrapReceiver2x2StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtTrapReceiver2x2TimeZone 12 }
|
|
|
|
wtTrapReceiver2x2StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtTrapReceiver2x2StopMode-first(1),
|
|
wtTrapReceiver2x2StopMode-second(2),
|
|
wtTrapReceiver2x2StopMode-third(3),
|
|
wtTrapReceiver2x2StopMode-fourth(4),
|
|
wtTrapReceiver2x2StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtTrapReceiver2x2TimeZone 13 }
|
|
|
|
wtTrapReceiver2x2StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtTrapReceiver2x2StopWday-Sunday(1),
|
|
wtTrapReceiver2x2StopWday-Monday(2),
|
|
wtTrapReceiver2x2StopWday-Tuesday(3),
|
|
wtTrapReceiver2x2StopWday-Thursday(4),
|
|
wtTrapReceiver2x2StopWday-Wednesday(5),
|
|
wtTrapReceiver2x2StopWday-Friday(6),
|
|
wtTrapReceiver2x2StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtTrapReceiver2x2TimeZone 14 }
|
|
|
|
wtTrapReceiver2x2StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtTrapReceiver2x2TimeZone 15 }
|
|
|
|
wtTrapReceiver2x2StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtTrapReceiver2x2TimeZone 16 }
|
|
|
|
-- wtTrapReceiver2x2TimeServer Group
|
|
----------------------------
|
|
|
|
wtTrapReceiver2x2TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtTrapReceiver2x2TimeServer 1 }
|
|
|
|
wtTrapReceiver2x2TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtTrapReceiver2x2TimeServer 2 }
|
|
|
|
wtTrapReceiver2x2TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtTrapReceiver2x2TimeServer 3 }
|
|
|
|
wtTrapReceiver2x2TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtTrapReceiver2x2TimeServer 4 }
|
|
|
|
|
|
-- wtTrapReceiver2x2DeviceClock Group
|
|
----------------------------
|
|
|
|
wtTrapReceiver2x2ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtTrapReceiver2x2DeviceClock 1 }
|
|
|
|
wtTrapReceiver2x2ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtTrapReceiver2x2DeviceClock 2 }
|
|
|
|
wtTrapReceiver2x2ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtTrapReceiver2x2DeviceClock 3 }
|
|
|
|
wtTrapReceiver2x2ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtTrapReceiver2x2ClockMonth-January(1),
|
|
wtTrapReceiver2x2ClockMonth-February(2),
|
|
wtTrapReceiver2x2ClockMonth-March(3),
|
|
wtTrapReceiver2x2ClockMonth-April(4),
|
|
wtTrapReceiver2x2ClockMonth-May(5),
|
|
wtTrapReceiver2x2ClockMonth-June(6),
|
|
wtTrapReceiver2x2ClockMonth-July(7),
|
|
wtTrapReceiver2x2ClockMonth-August(8),
|
|
wtTrapReceiver2x2ClockMonth-September(9),
|
|
wtTrapReceiver2x2ClockMonth-October(10),
|
|
wtTrapReceiver2x2ClockMonth-November(11),
|
|
wtTrapReceiver2x2ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtTrapReceiver2x2DeviceClock 4 }
|
|
|
|
wtTrapReceiver2x2ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtTrapReceiver2x2DeviceClock 5 }
|
|
|
|
-- wtTrapReceiver2x2Network Group
|
|
------------------------
|
|
|
|
wtTrapReceiver2x2IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtTrapReceiver2x2Network 1 }
|
|
|
|
wtTrapReceiver2x2SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtTrapReceiver2x2Network 2 }
|
|
|
|
wtTrapReceiver2x2Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtTrapReceiver2x2Network 3 }
|
|
|
|
wtTrapReceiver2x2DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtTrapReceiver2x2Network 4 }
|
|
|
|
wtTrapReceiver2x2DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtTrapReceiver2x2Network 5 }
|
|
|
|
wtTrapReceiver2x2AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP enable
|
|
Bit 0: BOOTP enable"
|
|
::= { wtTrapReceiver2x2Network 6 }
|
|
|
|
-- wtTrapReceiver2x2HTTP Group
|
|
--------------------------------
|
|
|
|
wtTrapReceiver2x2HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65534)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtTrapReceiver2x2HTTP 4 }
|
|
|
|
|
|
-- wtTrapReceiver2x2Mail Group
|
|
--------------------------------
|
|
|
|
wtTrapReceiver2x2MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtTrapReceiver2x2Mail 1 }
|
|
|
|
wtTrapReceiver2x2MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtTrapReceiver2x2Mail 2 }
|
|
|
|
wtTrapReceiver2x2MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtTrapReceiver2x2Mail 3 }
|
|
|
|
wtTrapReceiver2x2MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtTrapReceiver2x2Mail 4 }
|
|
|
|
wtTrapReceiver2x2MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtTrapReceiver2x2Mail 5 }
|
|
|
|
wtTrapReceiver2x2MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtTrapReceiver2x2Mail 6 }
|
|
|
|
wtTrapReceiver2x2MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtTrapReceiver2x2Mail 7 }
|
|
|
|
wtTrapReceiver2x2MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtTrapReceiver2x2Mail 8 }
|
|
|
|
|
|
-- wtTrapReceiver2x2Snmp Group
|
|
--------------------------------
|
|
|
|
wtTrapReceiver2x2SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtTrapReceiver2x2SNMP 1 }
|
|
|
|
wtTrapReceiver2x2SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtTrapReceiver2x2SNMP 2 }
|
|
|
|
wtTrapReceiver2x2SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtTrapReceiver2x2SNMP 3 }
|
|
|
|
wtTrapReceiver2x2SnmpSystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtTrapReceiver2x2SNMP 4 }
|
|
|
|
wtTrapReceiver2x2SnmpSystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag messages
|
|
Bit 3-7: unused"
|
|
::= { wtTrapReceiver2x2SNMP 5 }
|
|
|
|
-- wtTrapReceiver2x2UDP Group
|
|
--------------------------------
|
|
|
|
wtTrapReceiver2x2UdpAdminPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtTrapReceiver2x2UDP 1 }
|
|
|
|
wtTrapReceiver2x2UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtTrapReceiver2x2UDP 2 }
|
|
|
|
wtTrapReceiver2x2UdpRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp remote port setting.
|
|
If this value is set to zero, the source port read from a request will be used
|
|
as destination port for the answer.
|
|
A non zero value forced the destination port to this value."
|
|
::= { wtTrapReceiver2x2UDP 3 }
|
|
|
|
-- wtTrapReceiver2x2Syslog Group
|
|
--------------------------------
|
|
|
|
wtTrapReceiver2x2SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtTrapReceiver2x2Syslog 1 }
|
|
|
|
wtTrapReceiver2x2SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtTrapReceiver2x2Syslog 2 }
|
|
|
|
wtTrapReceiver2x2SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtTrapReceiver2x2Syslog 3 }
|
|
|
|
wtTrapReceiver2x2SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtTrapReceiver2x2Syslog 4 }
|
|
|
|
-- wtTrapReceiver2x2FTP Group
|
|
--------------------------------
|
|
|
|
wtTrapReceiver2x2FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtTrapReceiver2x2FTP 1 }
|
|
|
|
wtTrapReceiver2x2FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtTrapReceiver2x2FTP 2 }
|
|
|
|
wtTrapReceiver2x2FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtTrapReceiver2x2FTP 3 }
|
|
|
|
wtTrapReceiver2x2FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtTrapReceiver2x2FTP 4 }
|
|
|
|
wtTrapReceiver2x2FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtTrapReceiver2x2FTP 5 }
|
|
|
|
wtTrapReceiver2x2FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtTrapReceiver2x2FTP 6 }
|
|
|
|
wtTrapReceiver2x2FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtTrapReceiver2x2FTP 7 }
|
|
|
|
-- wtTrapReceiver2x2WatchList Group
|
|
----------------------------
|
|
|
|
wtTrapReceiver2x2WatchListCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of Ip addresses."
|
|
::= { wtTrapReceiver2x2WatchList 1 }
|
|
|
|
-- WatchList Interface Table
|
|
|
|
wtTrapReceiver2x2WatchListIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2WatchListIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of inices."
|
|
::= { wtTrapReceiver2x2WatchList 2 }
|
|
|
|
wtTrapReceiver2x2WatchListIfEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2WatchListIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table entry."
|
|
INDEX { wtTrapReceiver2x2WatchListNo }
|
|
::= { wtTrapReceiver2x2WatchListIfTable 1 }
|
|
|
|
WtTrapReceiver2x2WatchListIfEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2WatchListNo INTEGER
|
|
}
|
|
|
|
wtTrapReceiver2x2WatchListNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..999)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List number of this entry."
|
|
::= { wtTrapReceiver2x2WatchListIfEntry 1 }
|
|
|
|
-- WatchList Table
|
|
|
|
wtTrapReceiver2x2WatchListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2WatchListEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of ip addresses."
|
|
::= { wtTrapReceiver2x2WatchList 3 }
|
|
|
|
wtTrapReceiver2x2WatchListEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2WatchListEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List entry."
|
|
INDEX { wtTrapReceiver2x2WatchListNo }
|
|
::= { wtTrapReceiver2x2WatchListTable 1 }
|
|
|
|
WtTrapReceiver2x2WatchListEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2WatchListName OCTET STRING,
|
|
wtTrapReceiver2x2WatchListPort INTEGER,
|
|
wtTrapReceiver2x2WatchListService OCTET STRING,
|
|
wtTrapReceiver2x2WatchListEnable OCTET STRING,
|
|
wtTrapReceiver2x2WatchListAlias OCTET STRING,
|
|
wtTrapReceiver2x2WatchListTrapNo INTEGER,
|
|
wtTrapReceiver2x2WatchListSpecificNo INTEGER,
|
|
wtTrapReceiver2x2WatchListFacility INTEGER,
|
|
wtTrapReceiver2x2WatchListSeverity INTEGER
|
|
}
|
|
|
|
wtTrapReceiver2x2WatchListName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address."
|
|
::= { wtTrapReceiver2x2WatchListEntry 1 }
|
|
|
|
wtTrapReceiver2x2WatchListPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number, zero in the case of broadcast or Ping."
|
|
::= { wtTrapReceiver2x2WatchListEntry 2 }
|
|
|
|
wtTrapReceiver2x2WatchListService OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded scan mode, only one mode can be selected at a particular time:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: unused
|
|
Bit 1: unused
|
|
Bit 2: SNMP Trap reveive enable
|
|
Bit 3: Syslog receive enable
|
|
Bit 4-7: unused"
|
|
::= { wtTrapReceiver2x2WatchListEntry 3 }
|
|
|
|
wtTrapReceiver2x2WatchListEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3:
|
|
Bit 0: enabled in Report 9
|
|
Bit 1: enabled in Report 10
|
|
Bit 2: enabled in Report 11
|
|
Bit 3: enabled in Report 12
|
|
Bit 4-7: unused
|
|
Octet 4:
|
|
Bit 0: enabled in Report 1
|
|
Bit 1: enabled in Report 2
|
|
Bit 2: enabled in Report 3
|
|
Bit 3: enabled in Report 4
|
|
Bit 4: enabled in Report 5
|
|
Bit 5: enabled in Report 6
|
|
Bit 6: enabled in Report 7
|
|
Bit 7: enabled in Report 8"
|
|
::= { wtTrapReceiver2x2WatchListEntry 4 }
|
|
|
|
wtTrapReceiver2x2WatchListAlias OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alias Name"
|
|
::= { wtTrapReceiver2x2WatchListEntry 5 }
|
|
|
|
wtTrapReceiver2x2WatchListTrapNo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Trap No: this filter is only active, if SNMP Trap reveive enable in
|
|
wtTrapReceiver2x2WatchListService is set.
|
|
wtTrapReceiver2x2WatchListTrapNo-ColdStart(0),
|
|
wtTrapReceiver2x2WatchListTrapNo-WarmStart(1),
|
|
wtTrapReceiver2x2WatchListTrapNo-LinkDown(2),
|
|
wtTrapReceiver2x2WatchListTrapNo-LinkUp(3),
|
|
wtTrapReceiver2x2WatchListTrapNo-AuthFailure(4),
|
|
wtTrapReceiver2x2WatchListTrapNo-EPGneighborLoss(5),
|
|
wtTrapReceiver2x2WatchListTrapNo-EnterpriseSpecific(6),
|
|
wtTrapReceiver2x2WatchListTrapNo-WildCard(7)"
|
|
::= { wtTrapReceiver2x2WatchListEntry 6 }
|
|
|
|
wtTrapReceiver2x2WatchListSpecificNo OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SNMP Specific No: this filter is only active, if SNMP Trap reveive enable in
|
|
wtTrapReceiver2x2WatchListService is set."
|
|
::= { wtTrapReceiver2x2WatchListEntry 7 }
|
|
|
|
wtTrapReceiver2x2WatchListFacility OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Syslog message level Facility: this filter is only active, if Syslog receive enable in
|
|
wtTrapReceiver2x2WatchListService is set.
|
|
wtTrapReceiver2x2WatchListFacility-Emergency(0),
|
|
wtTrapReceiver2x2WatchListFacility-Alert(1),
|
|
wtTrapReceiver2x2WatchListFacility-Critical(2),
|
|
wtTrapReceiver2x2WatchListFacility-Error(3),
|
|
wtTrapReceiver2x2WatchListFacility-Warning(4),
|
|
wtTrapReceiver2x2WatchListFacility-Notice(5),
|
|
wtTrapReceiver2x2WatchListFacility-Informational(6),
|
|
wtTrapReceiver2x2WatchListFacility-Debug(7),
|
|
wtTrapReceiver2x2WatchListFacility-WildCard(8)"
|
|
::= { wtTrapReceiver2x2WatchListEntry 8 }
|
|
|
|
wtTrapReceiver2x2WatchListSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Syslog message level Severity: this filter is only active, if Syslog receive enable in
|
|
wtTrapReceiver2x2WatchListService is set.
|
|
wtTrapReceiver2x2WatchListSeverity-kernel-messages(0),
|
|
wtTrapReceiver2x2WatchListSeverity-user-level-messages(1),
|
|
wtTrapReceiver2x2WatchListSeverity-mail-system(2),
|
|
wtTrapReceiver2x2WatchListSeverity-system-daemons(3),
|
|
wtTrapReceiver2x2WatchListSeverity-security-auth-messages(4),
|
|
wtTrapReceiver2x2WatchListSeverity-msg-generated-by-syslogd(5),
|
|
wtTrapReceiver2x2WatchListSeverity-line-printer-subsystem(6),
|
|
wtTrapReceiver2x2WatchListSeverity-network-news-subsystem(7),
|
|
wtTrapReceiver2x2WatchListSeverity-UUCP-subsystem(8),
|
|
wtTrapReceiver2x2WatchListSeverity-clock-daemon(9),
|
|
wtTrapReceiver2x2WatchListSeverity-security-auth-msg-private(10),
|
|
wtTrapReceiver2x2WatchListSeverity-FTP-daemon(11),
|
|
wtTrapReceiver2x2WatchListSeverity-NTP-subsystem(12),
|
|
wtTrapReceiver2x2WatchListSeverity-log-audit(13),
|
|
wtTrapReceiver2x2WatchListSeverity-log-alert(14),
|
|
wtTrapReceiver2x2WatchListSeverity-clock-daemon-15(15),
|
|
wtTrapReceiver2x2WatchListSeverity-local0(16),
|
|
wtTrapReceiver2x2WatchListSeverity-local1(17),
|
|
wtTrapReceiver2x2WatchListSeverity-local2(18),
|
|
wtTrapReceiver2x2WatchListSeverity-local3(19),
|
|
wtTrapReceiver2x2WatchListSeverity-local4(20),
|
|
wtTrapReceiver2x2WatchListSeverity-local5(21),
|
|
wtTrapReceiver2x2WatchListSeverity-local6(22),
|
|
wtTrapReceiver2x2WatchListSeverity-local7(23),
|
|
wtTrapReceiver2x2WatchListSeverity-WildCard(24)
|
|
"
|
|
::= { wtTrapReceiver2x2WatchListEntry 9 }
|
|
|
|
-- wtTrapReceiver2x2OutputMode Group
|
|
----------------------------
|
|
|
|
wtTrapReceiver2x2PowerSupplyEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Setting this enable bit turns on the intarnal 24V power supply of the outputs.
|
|
All currents out must not exceed 150mA. At overcurrent condition the power supply will
|
|
be shut down automatically. To reset the ocvercurrent protection circuit
|
|
write 1 into wtTrapReceiver2x2DiagErrorClear.
|
|
Internal power supply is a feature of 57655 only.
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Power Supply enable"
|
|
::= { wtTrapReceiver2x2OutputMode 4 }
|
|
|
|
|
|
-- wtTrapReceiver2x2Action Group
|
|
----------------------------
|
|
|
|
wtTrapReceiver2x2ActionCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtTrapReceiver2x2Action 1 }
|
|
|
|
-- Action Interface Table
|
|
|
|
wtTrapReceiver2x2ActionIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2ActionIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtTrapReceiver2x2Action 2 }
|
|
|
|
wtTrapReceiver2x2ActionIfEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2ActionIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtTrapReceiver2x2ActionNo }
|
|
::= { wtTrapReceiver2x2ActionIfTable 1 }
|
|
|
|
WtTrapReceiver2x2ActionIfEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2ActionNo INTEGER
|
|
}
|
|
|
|
wtTrapReceiver2x2ActionNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..4)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
::= { wtTrapReceiver2x2ActionIfEntry 1 }
|
|
|
|
-- Action Table
|
|
|
|
wtTrapReceiver2x2ActionTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2ActionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtTrapReceiver2x2Action 3 }
|
|
|
|
wtTrapReceiver2x2ActionEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2ActionEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Action parameters of the individual alarms."
|
|
INDEX { wtTrapReceiver2x2ActionNo }
|
|
::= { wtTrapReceiver2x2ActionTable 1 }
|
|
|
|
WtTrapReceiver2x2ActionEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2ActionInputTrigger OCTET STRING,
|
|
wtTrapReceiver2x2ActionInterval OCTET STRING,
|
|
wtTrapReceiver2x2ActionEnable OCTET STRING,
|
|
wtTrapReceiver2x2ActionMailAddr OCTET STRING,
|
|
wtTrapReceiver2x2ActionMailSubject OCTET STRING,
|
|
wtTrapReceiver2x2ActionMailText OCTET STRING,
|
|
wtTrapReceiver2x2ActionSnmpManagerIP OCTET STRING,
|
|
wtTrapReceiver2x2ActionSnmpTrapText OCTET STRING,
|
|
wtTrapReceiver2x2ActionUdpIpAddr OCTET STRING,
|
|
wtTrapReceiver2x2ActionUdpPort INTEGER,
|
|
wtTrapReceiver2x2ActionUdpText OCTET STRING,
|
|
wtTrapReceiver2x2ActionTcpIpAddr OCTET STRING,
|
|
wtTrapReceiver2x2ActionTcpPort INTEGER,
|
|
wtTrapReceiver2x2ActionTcpText OCTET STRING,
|
|
wtTrapReceiver2x2ActionSyslogIpAddr OCTET STRING,
|
|
wtTrapReceiver2x2ActionSyslogPort INTEGER,
|
|
wtTrapReceiver2x2ActionSyslogText OCTET STRING,
|
|
wtTrapReceiver2x2ActionFtpDataPort OCTET STRING,
|
|
wtTrapReceiver2x2ActionFtpFileName OCTET STRING,
|
|
wtTrapReceiver2x2ActionFtpText OCTET STRING,
|
|
wtTrapReceiver2x2ActionFtpOption OCTET STRING,
|
|
wtTrapReceiver2x2ActionTimerCron OCTET STRING,
|
|
|
|
wtTrapReceiver2x2ActionName OCTET STRING,
|
|
wtTrapReceiver2x2ActionGlobalEnable OCTET STRING,
|
|
|
|
wtTrapReceiver2x2ActionSystemTimerTrigger OCTET STRING,
|
|
wtTrapReceiver2x2ActionSystemButtonTrigger OCTET STRING,
|
|
wtTrapReceiver2x2ActionOutputAction OCTET STRING
|
|
}
|
|
|
|
wtTrapReceiver2x2ActionInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual input trigger conditions.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The four OCTETS contain the mask which determines which of the inputs are to
|
|
be considered (corresponding bit = 1) and which inputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0: Input 0 falling edge
|
|
Bit 1: Input 0 rising edge
|
|
Bit 2: Input 1 falling edge
|
|
Bit 3: Input 1 rising edge
|
|
Bit 4-7: unused"
|
|
::= { wtTrapReceiver2x2ActionEntry 1 }
|
|
|
|
wtTrapReceiver2x2ActionInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtTrapReceiver2x2ActionEntry 5 }
|
|
|
|
wtTrapReceiver2x2ActionEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: UDP enable
|
|
Bit 3: Send inputs to pending TCP connections
|
|
Bit 4: TCP Client enable
|
|
Bit 5: Syslog Messages enable
|
|
Bit 6-7: unused"
|
|
::= { wtTrapReceiver2x2ActionEntry 6 }
|
|
|
|
wtTrapReceiver2x2ActionMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtTrapReceiver2x2ActionEntry 7 }
|
|
|
|
wtTrapReceiver2x2ActionMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtTrapReceiver2x2ActionEntry 8 }
|
|
|
|
wtTrapReceiver2x2ActionMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Action mail text:
|
|
States of the Webio device can be included by using special tags.
|
|
Please refer to the respective Webio manual"
|
|
::= { wtTrapReceiver2x2ActionEntry 9 }
|
|
|
|
wtTrapReceiver2x2ActionSnmpManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtTrapReceiver2x2ActionEntry 10 }
|
|
|
|
wtTrapReceiver2x2ActionSnmpTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the trap body."
|
|
::= { wtTrapReceiver2x2ActionEntry 11 }
|
|
|
|
wtTrapReceiver2x2ActionUdpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtTrapReceiver2x2ActionEntry 12 }
|
|
|
|
wtTrapReceiver2x2ActionUdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the UDP listener to which the Webio device should send UDP traps."
|
|
::= { wtTrapReceiver2x2ActionEntry 13 }
|
|
|
|
wtTrapReceiver2x2ActionUdpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the UDP trap body."
|
|
::= { wtTrapReceiver2x2ActionEntry 14 }
|
|
|
|
wtTrapReceiver2x2ActionTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtTrapReceiver2x2ActionEntry 15 }
|
|
|
|
wtTrapReceiver2x2ActionTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP listener to which the Webio device should send TCP traps."
|
|
::= { wtTrapReceiver2x2ActionEntry 16 }
|
|
|
|
wtTrapReceiver2x2ActionTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text appears in the TCP trap body."
|
|
::= { wtTrapReceiver2x2ActionEntry 17 }
|
|
|
|
wtTrapReceiver2x2ActionSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtTrapReceiver2x2ActionEntry 18 }
|
|
|
|
wtTrapReceiver2x2ActionSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtTrapReceiver2x2ActionEntry 19 }
|
|
|
|
wtTrapReceiver2x2ActionSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtTrapReceiver2x2ActionEntry 20 }
|
|
|
|
wtTrapReceiver2x2ActionFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtTrapReceiver2x2ActionEntry 21 }
|
|
|
|
wtTrapReceiver2x2ActionFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtTrapReceiver2x2ActionEntry 22 }
|
|
|
|
wtTrapReceiver2x2ActionFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtTrapReceiver2x2ActionEntry 23 }
|
|
|
|
wtTrapReceiver2x2ActionFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtTrapReceiver2x2ActionEntry 24 }
|
|
|
|
wtTrapReceiver2x2ActionTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 10 space or tab seperated text fields defining a time window for sending
|
|
time triggered messages. 2 CRON time for start time and stop time are defined as follows:
|
|
Start time:
|
|
field
|
|
1: Minutes Range 0-59
|
|
3. Hours Range 0-23, 0 is midnight
|
|
5: Day of month Range 1-31
|
|
7: Month Range 1-12
|
|
9: Weekday Range 0-6, 0 is sunday
|
|
|
|
Stop time:
|
|
field
|
|
2: Minutes Range 0-59
|
|
4. Hours Range 0-23, 0 is midnight
|
|
6: Day of month Range 1-31
|
|
8: Month Range 1-12
|
|
10: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtTrapReceiver2x2ActionEntry 25 }
|
|
|
|
|
|
wtTrapReceiver2x2ActionName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the alarm."
|
|
::= { wtTrapReceiver2x2ActionEntry 33 }
|
|
|
|
wtTrapReceiver2x2ActionGlobalEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm activation:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Action enable"
|
|
::= { wtTrapReceiver2x2ActionEntry 34 }
|
|
|
|
wtTrapReceiver2x2ActionSystemTimerTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded system timer activation:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0: System Timer 1 enable
|
|
Bit 1: System Timer 2 enable
|
|
Bit 2-7: unused"
|
|
::= { wtTrapReceiver2x2ActionEntry 55 }
|
|
|
|
wtTrapReceiver2x2ActionSystemButtonTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded button activation:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0: Button 1 enable
|
|
Bit 1: Button 2 enable
|
|
Bit 2: Button 3 enable
|
|
Bit 3: Button 4 enable
|
|
Bit 3: Button 5 enable
|
|
Bit 3: Button 6 enable
|
|
Bit 3: Button 7 enable
|
|
Bit 3: Button 8 enable."
|
|
::= { wtTrapReceiver2x2ActionEntry 56 }
|
|
|
|
wtTrapReceiver2x2ActionOutputAction OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(12))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This variable allows setting of individual output.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
The first four OCTETS contain the mask which determines which of the outputs are to
|
|
be considered (corresponding bit = 1) and which outputs are to ignore
|
|
(corresponding bit = 0):
|
|
OCTET 1 : unused
|
|
OCTET 2 : unused
|
|
OCTET 3 : unused
|
|
OCTET 4, Bit 0-1: Mask for digital outputs 0-1
|
|
|
|
OCTETS 5-8 contain the level (1=HIGH, 0=LOW) which the outputs
|
|
should assume:
|
|
OCTET 5 : unused
|
|
OCTET 6 : unused
|
|
OCTET 7 : unused
|
|
OCTET 8, Bit 0-1: Level of digital outputs 0-1
|
|
|
|
OCTETS 9-12 contain the TOOGLE bit (1=ON, 0=OFF). outputs masked with the TOGGLE bit trigger change
|
|
their state on every action. Settings in OCTET 5-9 are then unused:
|
|
OCTET 9: unused
|
|
OCTET 10: unused
|
|
OCTET 11: unused
|
|
OCTET 12, Bit 0-1: TOGGLE bits of digital outputs 0-1"
|
|
::= { wtTrapReceiver2x2ActionEntry 57 }
|
|
|
|
-- wtTrapReceiver2x2InEvSystemTimer Group
|
|
----------------------------
|
|
|
|
-- SystemTimer Table
|
|
|
|
wtTrapReceiver2x2SystemTimerPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2SystemTimerPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the SystemTimer number."
|
|
::= { wtTrapReceiver2x2InEvSystemTimer 1 }
|
|
|
|
wtTrapReceiver2x2SystemTimerPortEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2SystemTimerPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"SystemTimer parameter for the individual SystemTimer."
|
|
INDEX { wtTrapReceiver2x2SystemTimerNo }
|
|
::= { wtTrapReceiver2x2SystemTimerPortTable 1 }
|
|
|
|
WtTrapReceiver2x2SystemTimerPortEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2PortSystemTimerEnable OCTET STRING,
|
|
wtTrapReceiver2x2PortSystemTimerName OCTET STRING,
|
|
wtTrapReceiver2x2PortSystemTimerCron OCTET STRING
|
|
|
|
}
|
|
|
|
wtTrapReceiver2x2PortSystemTimerEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded SystemTimer enable:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: ungenutzt
|
|
OCTET 2: ungenutzt
|
|
OCTET 3: ungenutzt
|
|
OCTET 4, Bit 1-7: ungenutzt
|
|
Bit 0 : SystemTimer enable"
|
|
::= { wtTrapReceiver2x2SystemTimerPortEntry 1 }
|
|
|
|
wtTrapReceiver2x2PortSystemTimerName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the SystemTimer."
|
|
::= { wtTrapReceiver2x2SystemTimerPortEntry 2 }
|
|
|
|
wtTrapReceiver2x2PortSystemTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger a message, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas
|
|
- a partition within the allowed range (1-5)
|
|
- step size within an partition of the allowed range (0-59/2: every second minute)."
|
|
::= { wtTrapReceiver2x2SystemTimerPortEntry 3 }
|
|
|
|
-- wtTrapReceiver2x2InEvButtons Group
|
|
----------------------------
|
|
|
|
-- Button Table
|
|
|
|
wtTrapReceiver2x2ButtonPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2ButtonPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the button number."
|
|
::= { wtTrapReceiver2x2InEvButtons 1 }
|
|
|
|
wtTrapReceiver2x2ButtonPortEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2ButtonPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Button parameter for the individual buttons."
|
|
INDEX { wtTrapReceiver2x2ButtonNo }
|
|
::= { wtTrapReceiver2x2ButtonPortTable 1 }
|
|
|
|
WtTrapReceiver2x2ButtonPortEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2PortButtonEnable OCTET STRING,
|
|
wtTrapReceiver2x2PortButtonName OCTET STRING,
|
|
wtTrapReceiver2x2PortButtonText OCTET STRING,
|
|
wtTrapReceiver2x2PortButtonAccess OCTET STRING
|
|
}
|
|
|
|
wtTrapReceiver2x2PortButtonEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded button enable:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: ungenutzt
|
|
OCTET 2: ungenutzt
|
|
OCTET 3: ungenutzt
|
|
OCTET 4, Bit 1-7: ungenutzt
|
|
Bit 0 : Button enable"
|
|
::= { wtTrapReceiver2x2ButtonPortEntry 1 }
|
|
|
|
wtTrapReceiver2x2PortButtonName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the button."
|
|
::= { wtTrapReceiver2x2ButtonPortEntry 2 }
|
|
|
|
wtTrapReceiver2x2PortButtonText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the button."
|
|
::= { wtTrapReceiver2x2ButtonPortEntry 3 }
|
|
|
|
wtTrapReceiver2x2PortButtonAccess OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded button access level:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 3-7: unused
|
|
Bit 2 : For user administrator visible and operable
|
|
Bit 1 : For user operator visible and operable
|
|
Bit 0 : For user guest visible and operable"
|
|
::= { wtTrapReceiver2x2ButtonPortEntry 4 }
|
|
|
|
|
|
-- wtTrapReceiver2x2InEvInputs Group
|
|
----------------------------
|
|
|
|
-- Input Port Table
|
|
|
|
|
|
wtTrapReceiver2x2InputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the input number."
|
|
::= { wtTrapReceiver2x2InEvInputs 1 }
|
|
|
|
wtTrapReceiver2x2InputPortEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2InputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Input parameter for the individual inputs."
|
|
INDEX { wtTrapReceiver2x2InputNo }
|
|
::= { wtTrapReceiver2x2InputPortTable 1 }
|
|
|
|
WtTrapReceiver2x2InputPortEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2PortInputName OCTET STRING,
|
|
wtTrapReceiver2x2PortInputText OCTET STRING,
|
|
wtTrapReceiver2x2PortInputFilter INTEGER
|
|
}
|
|
|
|
wtTrapReceiver2x2PortInputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the input."
|
|
::= { wtTrapReceiver2x2InputPortEntry 1 }
|
|
|
|
wtTrapReceiver2x2PortInputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the input."
|
|
::= { wtTrapReceiver2x2InputPortEntry 2 }
|
|
|
|
wtTrapReceiver2x2PortInputFilter OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulses with a duration shorter than here specified (duration in 1/1000 sec),
|
|
are ignored."
|
|
::= { wtTrapReceiver2x2InputPortEntry 4 }
|
|
|
|
-- wtTrapReceiver2x2OutEvOutputs Group
|
|
|
|
wtTrapReceiver2x2OutputPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtTrapReceiver2x2OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the output number."
|
|
::= { wtTrapReceiver2x2OutEvOutputs 1 }
|
|
|
|
wtTrapReceiver2x2OutputPortEntry OBJECT-TYPE
|
|
SYNTAX WtTrapReceiver2x2OutputPortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Output parameters of the individual outputs."
|
|
INDEX { wtTrapReceiver2x2OutputNo }
|
|
::= { wtTrapReceiver2x2OutputPortTable 1 }
|
|
|
|
WtTrapReceiver2x2OutputPortEntry ::= SEQUENCE {
|
|
wtTrapReceiver2x2PortOutputName OCTET STRING,
|
|
wtTrapReceiver2x2PortOutputText OCTET STRING,
|
|
wtTrapReceiver2x2PortPulseDuration INTEGER,
|
|
wtTrapReceiver2x2PortPulsePolarity OCTET STRING
|
|
|
|
}
|
|
|
|
wtTrapReceiver2x2PortOutputName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the output."
|
|
::= { wtTrapReceiver2x2OutputPortEntry 1 }
|
|
|
|
wtTrapReceiver2x2PortOutputText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the output."
|
|
::= { wtTrapReceiver2x2OutputPortEntry 2 }
|
|
|
|
wtTrapReceiver2x2PortPulseDuration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Pulse length in 1/1000 sec. Setting this value to zero, disables the pulse output."
|
|
::= { wtTrapReceiver2x2OutputPortEntry 9 }
|
|
|
|
wtTrapReceiver2x2PortPulsePolarity OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value defines the polarity of the output pulse, if wtTrapReceiver2x2PortPulseDuration is not set to zero.
|
|
After the pulse is finished, the output switches back to the opposite state.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4:
|
|
Bit 0 : negative polarity
|
|
Bit 1 : positive polarity
|
|
Bit 2-7 : unused"
|
|
::= { wtTrapReceiver2x2OutputPortEntry 10 }
|
|
|
|
-- wtTrapReceiver2x2Manufact Group
|
|
----------------------------
|
|
|
|
wtTrapReceiver2x2MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtTrapReceiver2x2Manufact 1 }
|
|
|
|
wtTrapReceiver2x2MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtTrapReceiver2x2Manufact 2 }
|
|
|
|
wtTrapReceiver2x2MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtTrapReceiver2x2Manufact 3 }
|
|
|
|
wtTrapReceiver2x2MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtTrapReceiver2x2Manufact 4 }
|
|
|
|
wtTrapReceiver2x2MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtTrapReceiver2x2Manufact 5 }
|
|
|
|
-- wtTrapReceiver2x2Diag Group
|
|
----------------------------
|
|
|
|
wtTrapReceiver2x2DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtTrapReceiver2x2Diag 1 }
|
|
|
|
wtTrapReceiver2x2DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtTrapReceiver2x2Diag 2 }
|
|
|
|
wtTrapReceiver2x2DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtTrapReceiver2x2DiagErrorMessage.
|
|
Errors are numbered from 1 to wtTrapReceiver2x2DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtTrapReceiver2x2DiagErrorMessage."
|
|
::= { wtTrapReceiver2x2Diag 3 }
|
|
|
|
wtTrapReceiver2x2DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtTrapReceiver2x2DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtTrapReceiver2x2Diag 4 }
|
|
|
|
wtTrapReceiver2x2DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtTrapReceiver2x2Diag 5 }
|
|
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- These SNMP traps will be send, if the appropriate trigger condition match
|
|
|
|
wtTrapReceiver2x2Alert1 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 1"
|
|
--#SUMMARY "Action 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 41
|
|
|
|
wtTrapReceiver2x2Alert2 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 2"
|
|
--#SUMMARY "Action 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 42
|
|
|
|
wtTrapReceiver2x2Alert3 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 3"
|
|
--#SUMMARY "Action 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 43
|
|
|
|
wtTrapReceiver2x2Alert4 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 4"
|
|
--#SUMMARY "Action 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 44
|
|
|
|
wtTrapReceiver2x2Alert5 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 5"
|
|
--#SUMMARY "Action 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 45
|
|
|
|
wtTrapReceiver2x2Alert6 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 6"
|
|
--#SUMMARY "Action 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 46
|
|
|
|
wtTrapReceiver2x2Alert7 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 7"
|
|
--#SUMMARY "Action 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 47
|
|
|
|
wtTrapReceiver2x2Alert8 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 8"
|
|
--#SUMMARY "Action 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 48
|
|
|
|
wtTrapReceiver2x2Alert9 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 9 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 9"
|
|
--#SUMMARY "Action 9: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 49
|
|
|
|
wtTrapReceiver2x2Alert10 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 10 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 10"
|
|
--#SUMMARY "Action 10: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 50
|
|
|
|
wtTrapReceiver2x2Alert11 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 11 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 11"
|
|
--#SUMMARY "Action 11: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 51
|
|
|
|
wtTrapReceiver2x2Alert12 TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES { wtTrapReceiver2x2ActionSnmpTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Action 12 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Action 12"
|
|
--#SUMMARY "Action 12: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 52
|
|
|
|
|
|
|
|
wtTrapReceiver2x2AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtTrapReceiver2x2
|
|
VARIABLES {
|
|
wtTrapReceiver2x2DiagErrorIndex,
|
|
wtTrapReceiver2x2DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Trap-Receiver Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
--------------------------------------------------------------------------------
|
|
|
|
|
|
|
|
END
|