WebGraph-AnalogIO-57762-US-MIB DEFINITIONS ::= BEGIN
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.31
|
|
----------------------------------------------------------------
|
|
-- 27.03.2018 New: Mail Auth, SNMP destination port
|
|
-- Binary HttpPort, time base report
|
|
-- MQTT, REST
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.30
|
|
----------------------------------------------------------------
|
|
-- 08.01.2010 New: Reports
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.29
|
|
----------------------------------------------------------------
|
|
-- 01.10.2009 Webio
|
|
-- New Analog Out: 57762
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.28
|
|
----------------------------------------------------------------
|
|
-- 02.12.2008 Webio
|
|
-- New Graphics java script base parameter
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.27
|
|
----------------------------------------------------------------
|
|
-- 09.11.2006 Webio
|
|
-- DHCP enable
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.26
|
|
----------------------------------------------------------------
|
|
-- 28.06.2006 New: Community String Trap
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.25
|
|
----------------------------------------------------------------
|
|
-- 25.11.2005 #57641, WebGraph AnalogIn
|
|
-- OID correction
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.24
|
|
----------------------------------------------------------------
|
|
-- 26.07.2005 #57641, WebGraph AnalogIn
|
|
-- CRON timer function
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.23
|
|
----------------------------------------------------------------
|
|
-- 14.07.2005 #57641, WebGraph AnalogIn
|
|
-- FTP functions
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.22
|
|
----------------------------------------------------------------
|
|
-- 17.05.2005 #57641, WebGraph AnalogIn
|
|
-- Trap NMS annotations
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.21
|
|
----------------------------------------------------------------
|
|
-- 19.04.2005 #57605, WebGraph Themometer
|
|
-- Mail Authentication
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.20
|
|
----------------------------------------------------------------
|
|
-- 05.11.2004 #57606, WebGraph Thermo-Hygrometer
|
|
-- New: Syslog
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.19
|
|
----------------------------------------------------------------
|
|
-- 08.09.2004 #57606 WebGraph Thermo-Hygrometer
|
|
-- New:
|
|
-- wtWebGraphThermHygroAlarmRHMin
|
|
-- wtWebGraphThermHygroAlarmRHMax
|
|
-- wtWebGraphThermHygroAlarmRHHysteresis
|
|
-- wtWebGraphThermHygroPortSensorSelect
|
|
-- wtWebGraphThermHygroAlarmDeltaTemp
|
|
-- wtWebGraphThermHygroAlarmAHMin
|
|
-- wtWebGraphThermHygroAlarmAHMax
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.18
|
|
----------------------------------------------------------------
|
|
-- 21.07.2004 #57601/3/4, Webio Anx
|
|
-- New:
|
|
-- Diagnosis
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.17
|
|
----------------------------------------------------------------
|
|
-- 28.06.2004 #57630/1/2, Webio Digital
|
|
-- Neu: Puls Mode
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.16
|
|
----------------------------------------------------------------
|
|
-- 16.04.2004 New: #57632, Webio Digital EA24x24
|
|
--
|
|
-- #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- wtWebioEA12x12InputCounterClear
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.15
|
|
----------------------------------------------------------------
|
|
-- 27.02.2004 #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- Length changed to 32 Bit:
|
|
-- wtWebioEA12x12InputValue
|
|
-- wtWebioEA12x12OutputValue
|
|
-- wtWebioEA12x12LoadControlView
|
|
-- wtWebioEA12x12LCShutDownView
|
|
-- wtWebioEA12x12SetOutput
|
|
-- wtWebioEA12x12AlarmInputTrigger
|
|
-- wtWebioEA12x12AlarmOutputTrigger
|
|
-- wtWebioEA12x12PortOutputSafetyState
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.14
|
|
----------------------------------------------------------------
|
|
-- 16.02.2004 #57630/1, Webio Digital EA12x12
|
|
-- New:
|
|
-- Text: Location, Contact
|
|
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
|
|
-- Alarm: ColdStart / WarmStart trigger
|
|
--
|
|
-- #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New:
|
|
-- Alarm Hysteresis
|
|
-- Alarm Clear Traps and Mails
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.13
|
|
----------------------------------------------------------------
|
|
-- 05.02.2004 #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New:
|
|
-- Text: Location, Contact
|
|
-- SNMP: ColdStart, WarmStart, ComunityString Read/RW
|
|
-- Alarm: ColdStart / WarmStart trigger
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.12
|
|
----------------------------------------------------------------
|
|
-- 05.11.2003 #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer
|
|
-- #57604, 8xWebThermometer
|
|
-- New features:
|
|
-- Mail : Option CSV attachment
|
|
-- Port : Offset calibration
|
|
-- Alarm : TCP Client mode
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.11
|
|
----------------------------------------------------------------
|
|
-- 28.10.2003 #57630/1, Webio Digital EA12x12
|
|
-- New features:
|
|
-- Alarm : TCP Client mode
|
|
-- Inputs: Puls filter
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.10
|
|
----------------------------------------------------------------
|
|
-- 22.07.2003 #57630, Webio Digital EA12x12
|
|
-- New navigation tree, new binary modes
|
|
--
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.09
|
|
----------------------------------------------------------------
|
|
-- 24.03.2003 Trap Enterprise (Type 1, 2) corrected
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.08
|
|
----------------------------------------------------------------
|
|
-- 04.03.2003 reconciled the language versions DE/US
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.07
|
|
----------------------------------------------------------------
|
|
-- 25.02.2003 Correction: wtWebioEA12x12LoadControl
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.06
|
|
----------------------------------------------------------------
|
|
-- 24.02.2003 New:
|
|
-- #57630, Webio EA12x12, LoadControl Group
|
|
-- Correction: Trap variable names
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.05
|
|
----------------------------------------------------------------
|
|
-- 21.01.2003 New:
|
|
-- #57630, Webio EA12x12
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.04
|
|
----------------------------------------------------------------
|
|
-- 02.01.2003 New:
|
|
-- #57601, 1xWebThermometer
|
|
-- #57603, 2xWebThermometer, 8 alarms
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.03
|
|
----------------------------------------------------------------
|
|
-- 21.11.2002 New:
|
|
-- #57604, 2xWebThermometer, BOOTP, StartupSite
|
|
-- #57603, 8xWebThermometer, BOOTP, StartupSite
|
|
----------------------------------------------------------------
|
|
-- Revison: 1.02
|
|
----------------------------------------------------------------
|
|
-- 26.07.2002 New:
|
|
-- #57604, 2xWebThermometer
|
|
-- #57603, 8xWebThermometer
|
|
--
|
|
|
|
|
|
IMPORTS
|
|
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215
|
|
DisplayString, PhysAddress FROM RFC1213-MIB
|
|
enterprises, TimeTicks, IpAddress, NetworkAddress FROM RFC1155-SMI;
|
|
|
|
|
|
-- IpAddress ::=
|
|
-- [APPLICATION 0]
|
|
-- IMPLICIT OCTET STRING (SIZE (4))
|
|
-- Counter ::=
|
|
-- [APPLICATION 1]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
-- Gauge ::=
|
|
-- [APPLICATION 2]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
-- TimeTicks ::=
|
|
-- [APPLICATION 3]
|
|
-- IMPLICIT INTEGER (0..4294967295)
|
|
|
|
|
|
-- DisplayString ::= OCTET STRING
|
|
-- PhysAddress ::= OCTET STRING
|
|
|
|
-- internet OBJECT IDENTIFIER ::= { iso org(3) dod(6) 1 }
|
|
-- privat OBJECT IDENTIFIER ::= { internet 4 }
|
|
-- enterprises OBJECT IDENTIFIER ::= { privat 1 }
|
|
|
|
|
|
|
|
-- Wiesemann & Theis Com-Server MIB
|
|
|
|
wut OBJECT IDENTIFIER ::= { enterprises 5040 }
|
|
wtComServer OBJECT IDENTIFIER ::= { wut 1 }
|
|
wtWebio OBJECT IDENTIFIER ::= { wtComServer 2 }
|
|
|
|
-- wtWebGraph Tree
|
|
|
|
wtWebGraphAnalog57762 OBJECT IDENTIFIER ::= { wtWebio 29 }
|
|
|
|
-- wtWebGraphAnalog57762 Tree
|
|
|
|
wtWebGraphAnalog57762Inventory OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 1 }
|
|
wtWebGraphAnalog57762SessCntrl OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 2 }
|
|
wtWebGraphAnalog57762Config OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 3 }
|
|
wtWebGraphAnalog57762Diag OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762 4 }
|
|
|
|
-- wtWebGraphAnalog57762Config Tree
|
|
|
|
wtWebGraphAnalog57762Device OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 1 }
|
|
wtWebGraphAnalog57762Ports OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 2 }
|
|
wtWebGraphAnalog57762Manufact OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Config 3 }
|
|
|
|
-- wtWebGraphAnalog57762Device Tree
|
|
|
|
wtWebGraphAnalog57762Text OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 1 }
|
|
wtWebGraphAnalog57762TimeDate OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 2 }
|
|
wtWebGraphAnalog57762Basic OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 3 }
|
|
wtWebGraphAnalog57762Datalogger OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 4 }
|
|
wtWebGraphAnalog57762Alarm OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 5 }
|
|
wtWebGraphAnalog57762Graphics OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Device 6 }
|
|
|
|
-- wtWebGraphAnalog57762TimeDate Tree
|
|
|
|
wtWebGraphAnalog57762TimeZone OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 1 }
|
|
wtWebGraphAnalog57762TimeServer OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 2 }
|
|
wtWebGraphAnalog57762DeviceClock OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762TimeDate 3 }
|
|
|
|
-- wtWebGraphAnalog57762Basic Tree
|
|
|
|
wtWebGraphAnalog57762Network OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 1 }
|
|
wtWebGraphAnalog57762HTTP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 2 }
|
|
wtWebGraphAnalog57762Mail OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 3 }
|
|
wtWebGraphAnalog57762SNMP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 4 }
|
|
wtWebGraphAnalog57762UDP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 5 }
|
|
wtWebGraphAnalog57762Syslog OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 6 }
|
|
wtWebGraphAnalog57762FTP OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 7 }
|
|
wtWebGraphAnalog57762Language OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 8 }
|
|
wtWebGraphAnalog57762Binary OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 9 }
|
|
wtWebGraphAnalog57762MQTT OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 12 }
|
|
wtWebGraphAnalog57762REST OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Basic 13 }
|
|
|
|
-- wtWebGraphAnalog57762Graphics Tree
|
|
|
|
wtWebGraphAnalog57762GraphicsBase OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 1 }
|
|
wtWebGraphAnalog57762GraphicsSelect OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 2 }
|
|
wtWebGraphAnalog57762GraphicsScale OBJECT IDENTIFIER ::= { wtWebGraphAnalog57762Graphics 3 }
|
|
|
|
-- wtWebGraphAnalog57762Inventory Group
|
|
------------------------
|
|
|
|
wtWebGraphAnalog57762Sensors OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of sensors"
|
|
::= { wtWebGraphAnalog57762Inventory 1 }
|
|
|
|
-- Interface Table
|
|
|
|
wtWebGraphAnalog57762SensorTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensors."
|
|
::= { wtWebGraphAnalog57762Inventory 2 }
|
|
|
|
wtWebGraphAnalog57762SensorEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762SensorEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensor numbers."
|
|
INDEX { wtWebGraphAnalog57762SensorNo }
|
|
::= { wtWebGraphAnalog57762SensorTable 1 }
|
|
|
|
WtWebGraphAnalog57762SensorEntry ::= SEQUENCE {
|
|
wtWebGraphAnalog57762SensorNo INTEGER
|
|
}
|
|
|
|
wtWebGraphAnalog57762SensorNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor number."
|
|
::= { wtWebGraphAnalog57762SensorEntry 1 }
|
|
|
|
-- wtWebGraphAnalog57762Values Table
|
|
|
|
wtWebGraphAnalog57762ValuesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762ValuesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphAnalog57762Inventory 3 }
|
|
|
|
wtWebGraphAnalog57762ValuesEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762ValuesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement values of the sensors."
|
|
INDEX { wtWebGraphAnalog57762SensorNo }
|
|
::= { wtWebGraphAnalog57762ValuesTable 1 }
|
|
|
|
WtWebGraphAnalog57762ValuesEntry ::= SEQUENCE{
|
|
wtWebGraphAnalog57762Values OCTET STRING
|
|
}
|
|
|
|
wtWebGraphAnalog57762Values OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (5))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement value of the sensor, ASCII.
|
|
This value will be translated according to the ports settings
|
|
for the read and write operations."
|
|
::= { wtWebGraphAnalog57762ValuesEntry 1 }
|
|
|
|
|
|
-- wtWebGraphAnalog57762BinaryValues Table
|
|
|
|
wtWebGraphAnalog57762BinaryValuesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryValuesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of binary measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphAnalog57762Inventory 4 }
|
|
|
|
wtWebGraphAnalog57762BinaryValuesEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762BinaryValuesEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary measurement values of the sensors."
|
|
INDEX { wtWebGraphAnalog57762SensorNo }
|
|
::= { wtWebGraphAnalog57762BinaryValuesTable 1 }
|
|
|
|
WtWebGraphAnalog57762BinaryValuesEntry ::= SEQUENCE{
|
|
wtWebGraphAnalog57762BinaryValues INTEGER
|
|
}
|
|
|
|
wtWebGraphAnalog57762BinaryValues OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary measurement value of the sensor in 1/1000,
|
|
signed number, 0x7FFFFFFF indicates an invalid value.
|
|
This value will be translated according to the ports settings
|
|
for the read and write operations."
|
|
::= { wtWebGraphAnalog57762BinaryValuesEntry 1 }
|
|
|
|
-- wtWebGraphAnalog57762ValuesPoint Table
|
|
|
|
wtWebGraphAnalog57762ValuesPointTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762ValuesPointEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of measurement values corresponding to the channel numbers."
|
|
::= { wtWebGraphAnalog57762Inventory 8 }
|
|
|
|
wtWebGraphAnalog57762ValuesPointEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762ValuesPointEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement values of the sensors."
|
|
INDEX { wtWebGraphAnalog57762SensorNo }
|
|
::= { wtWebGraphAnalog57762ValuesPointTable 1 }
|
|
|
|
WtWebGraphAnalog57762ValuesPointEntry ::= SEQUENCE{
|
|
wtWebGraphAnalog57762ValuesPoint OCTET STRING
|
|
}
|
|
|
|
wtWebGraphAnalog57762ValuesPoint OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (5))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Measurement value of the sensor, ASCII.
|
|
This value will be translated according to the ports settings
|
|
for the read and write operations."
|
|
::= { wtWebGraphAnalog57762ValuesPointEntry 1 }
|
|
|
|
|
|
-- wtWebGraphAnalog57762SessCntrl Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762SessCntrlPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Entering this password opens a session which is ended by writing a 1 to
|
|
wtWebGraphAnalog57762SessCntrlLogout. When read this variable provides a string of
|
|
length zero."
|
|
::= { wtWebGraphAnalog57762SessCntrl 1 }
|
|
|
|
wtWebGraphAnalog57762SessCntrlConfigMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762SessCntrl-NoSession(0),
|
|
wtWebGraphAnalog57762SessCntrl-Session(1)
|
|
}
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"When the device is in SNMP configuration mode, the value 1 is
|
|
returned, otherwise 0. If the read value is 0 even though the
|
|
password was written, the device is already in config mode and the
|
|
variables can only be read."
|
|
::= { wtWebGraphAnalog57762SessCntrl 2 }
|
|
|
|
wtWebGraphAnalog57762SessCntrlLogout OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If the device is in configuration mode and the session was opened by
|
|
this SNMP Manager, writing a 1 to this variable will end the session
|
|
and all parameters are stored.
|
|
Writing a 2 discards all entries again.
|
|
When read this variable provides the value 0."
|
|
::= { wtWebGraphAnalog57762SessCntrl 3 }
|
|
|
|
wtWebGraphAnalog57762SessCntrlAdminPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with administrator rights.
|
|
It can only be changed by the administrator. If no password was assigned,
|
|
the valid password is public."
|
|
::= { wtWebGraphAnalog57762SessCntrl 4 }
|
|
|
|
wtWebGraphAnalog57762SessCntrlConfigPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This password protects access to the variables with configurator rights. It can
|
|
be changed by the administrator and by the configurator. If no password was assigned,
|
|
the valid password is public. When read this variable provides a null-pointer."
|
|
::= { wtWebGraphAnalog57762SessCntrl 5 }
|
|
|
|
|
|
-- wtWebGraphAnalog57762Text Group
|
|
------------------------
|
|
|
|
wtWebGraphAnalog57762DeviceName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the Webio, which is user definable."
|
|
::= { wtWebGraphAnalog57762Text 1 }
|
|
|
|
wtWebGraphAnalog57762DeviceText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the Webio, which is user definable."
|
|
::= { wtWebGraphAnalog57762Text 2 }
|
|
|
|
wtWebGraphAnalog57762DeviceLocation OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the location of the Webio, which is user definable."
|
|
::= { wtWebGraphAnalog57762Text 3 }
|
|
|
|
wtWebGraphAnalog57762DeviceContact OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Contact address of the system operator of the Webio, which is user definable."
|
|
::= { wtWebGraphAnalog57762Text 4 }
|
|
|
|
-- wtWebGraphAnalog57762TimeZone Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762TzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebGraphAnalog57762TimeZone 1 }
|
|
|
|
wtWebGraphAnalog57762TzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes for the time zone (winter time) with respect to UTC."
|
|
::= { wtWebGraphAnalog57762TimeZone 2 }
|
|
|
|
wtWebGraphAnalog57762TzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Timezone"
|
|
::= { wtWebGraphAnalog57762TimeZone 3 }
|
|
|
|
wtWebGraphAnalog57762StTzOffsetHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset hours of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebGraphAnalog57762TimeZone 4 }
|
|
|
|
wtWebGraphAnalog57762StTzOffsetMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset minutes of the time zone (summer time) with respect to UTC."
|
|
::= { wtWebGraphAnalog57762TimeZone 5 }
|
|
|
|
wtWebGraphAnalog57762StTzEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Summertime"
|
|
::= { wtWebGraphAnalog57762TimeZone 6 }
|
|
|
|
wtWebGraphAnalog57762StTzStartMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762StartMonth-January(1),
|
|
wtWebGraphAnalog57762StartMonth-February(2),
|
|
wtWebGraphAnalog57762StartMonth-March(3),
|
|
wtWebGraphAnalog57762StartMonth-April(4),
|
|
wtWebGraphAnalog57762StartMonth-May(5),
|
|
wtWebGraphAnalog57762StartMonth-June(6),
|
|
wtWebGraphAnalog57762StartMonth-July(7),
|
|
wtWebGraphAnalog57762StartMonth-August(8),
|
|
wtWebGraphAnalog57762StartMonth-September(9),
|
|
wtWebGraphAnalog57762StartMonth-October(10),
|
|
wtWebGraphAnalog57762StartMonth-November(11),
|
|
wtWebGraphAnalog57762StartMonth-December(12)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from winter time to summer time."
|
|
::= { wtWebGraphAnalog57762TimeZone 7 }
|
|
|
|
wtWebGraphAnalog57762StTzStartMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762StartMode-first(1),
|
|
wtWebGraphAnalog57762StartMode-second(2),
|
|
wtWebGraphAnalog57762StartMode-third(3),
|
|
wtWebGraphAnalog57762StartMode-fourth(4),
|
|
wtWebGraphAnalog57762StartMode-last(5)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the day of the week for which the change is made from winter time to summer time."
|
|
::= { wtWebGraphAnalog57762TimeZone 8 }
|
|
|
|
wtWebGraphAnalog57762StTzStartWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762StartWday-Sunday(1),
|
|
wtWebGraphAnalog57762StartWday-Monday(2),
|
|
wtWebGraphAnalog57762StartWday-Tuesday(3),
|
|
wtWebGraphAnalog57762StartWday-Thursday(4),
|
|
wtWebGraphAnalog57762StartWday-Wednesday(5),
|
|
wtWebGraphAnalog57762StartWday-Friday(6),
|
|
wtWebGraphAnalog57762StartWday-Saturday(7)
|
|
}
|
|
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from winter time to summer time"
|
|
::= { wtWebGraphAnalog57762TimeZone 9 }
|
|
|
|
wtWebGraphAnalog57762StTzStartHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebGraphAnalog57762TimeZone 10 }
|
|
|
|
wtWebGraphAnalog57762StTzStartMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute in which the time zone is changed from winter to summer time with
|
|
respect to UTC."
|
|
::= { wtWebGraphAnalog57762TimeZone 11 }
|
|
|
|
wtWebGraphAnalog57762StTzStopMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762StopMonth-January(1),
|
|
wtWebGraphAnalog57762StopMonth-February(2),
|
|
wtWebGraphAnalog57762StopMonth-March(3),
|
|
wtWebGraphAnalog57762StopMonth-April(4),
|
|
wtWebGraphAnalog57762StopMonth-May(5),
|
|
wtWebGraphAnalog57762StopMonth-June(6),
|
|
wtWebGraphAnalog57762StopMonth-July(7),
|
|
wtWebGraphAnalog57762StopMonth-August(8),
|
|
wtWebGraphAnalog57762StopMonth-September(9),
|
|
wtWebGraphAnalog57762StopMonth-October(10),
|
|
wtWebGraphAnalog57762StopMonth-November(11),
|
|
wtWebGraphAnalog57762StopMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Month in which the change is made from summer time to winter time."
|
|
::= { wtWebGraphAnalog57762TimeZone 12 }
|
|
|
|
wtWebGraphAnalog57762StTzStopMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762StopMode-first(1),
|
|
wtWebGraphAnalog57762StopMode-second(2),
|
|
wtWebGraphAnalog57762StopMode-third(3),
|
|
wtWebGraphAnalog57762StopMode-fourth(4),
|
|
wtWebGraphAnalog57762StopMode-last(5)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Mode of the week day on which the change is made from summer time to winter time."
|
|
::= { wtWebGraphAnalog57762TimeZone 13 }
|
|
|
|
wtWebGraphAnalog57762StTzStopWday OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762StopWday-Sunday(1),
|
|
wtWebGraphAnalog57762StopWday-Monday(2),
|
|
wtWebGraphAnalog57762StopWday-Tuesday(3),
|
|
wtWebGraphAnalog57762StopWday-Thursday(4),
|
|
wtWebGraphAnalog57762StopWday-Wednesday(5),
|
|
wtWebGraphAnalog57762StopWday-Friday(6),
|
|
wtWebGraphAnalog57762StopWday-Saturday(7)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Day of the week on which the change is made from summer time to winter time."
|
|
::= { wtWebGraphAnalog57762TimeZone 14 }
|
|
|
|
wtWebGraphAnalog57762StTzStopHrs OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hour at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebGraphAnalog57762TimeZone 15 }
|
|
|
|
wtWebGraphAnalog57762StTzStopMin OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minute at which the time zone is changed from summer to winter time with
|
|
respect to UTC."
|
|
::= { wtWebGraphAnalog57762TimeZone 16 }
|
|
|
|
-- wtWebGraphAnalog57762TimeServer Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762TimeServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 1st time server in ASCII"
|
|
::= { wtWebGraphAnalog57762TimeServer 1 }
|
|
|
|
wtWebGraphAnalog57762TimeServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address or name of the 2nd time server in ASCII"
|
|
::= { wtWebGraphAnalog57762TimeServer 2 }
|
|
|
|
wtWebGraphAnalog57762TsEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Apply Time Server"
|
|
::= { wtWebGraphAnalog57762TimeServer 3 }
|
|
|
|
wtWebGraphAnalog57762TsSyncTime OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Daily synchronisation time with the time server (hour: 0-23)."
|
|
::= { wtWebGraphAnalog57762TimeServer 4 }
|
|
|
|
-- wtWebGraphAnalog57762DeviceClock Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762ClockHrs OBJECT-TYPE
|
|
SYNTAX INTEGER (0..23)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock hours taking into account the time zone settings."
|
|
::= { wtWebGraphAnalog57762DeviceClock 1 }
|
|
|
|
wtWebGraphAnalog57762ClockMin OBJECT-TYPE
|
|
SYNTAX INTEGER (0..59)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Clock minutes taking into account the time zone settings."
|
|
::= { wtWebGraphAnalog57762DeviceClock 2 }
|
|
|
|
wtWebGraphAnalog57762ClockDay OBJECT-TYPE
|
|
SYNTAX INTEGER (1..31)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Day of the month, taking into account the time zone settings."
|
|
::= { wtWebGraphAnalog57762DeviceClock 3 }
|
|
|
|
wtWebGraphAnalog57762ClockMonth OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762ClockMonth-January(1),
|
|
wtWebGraphAnalog57762ClockMonth-February(2),
|
|
wtWebGraphAnalog57762ClockMonth-March(3),
|
|
wtWebGraphAnalog57762ClockMonth-April(4),
|
|
wtWebGraphAnalog57762ClockMonth-May(5),
|
|
wtWebGraphAnalog57762ClockMonth-June(6),
|
|
wtWebGraphAnalog57762ClockMonth-July(7),
|
|
wtWebGraphAnalog57762ClockMonth-August(8),
|
|
wtWebGraphAnalog57762ClockMonth-September(9),
|
|
wtWebGraphAnalog57762ClockMonth-October(10),
|
|
wtWebGraphAnalog57762ClockMonth-November(11),
|
|
wtWebGraphAnalog57762ClockMonth-December(12)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Month, taking into account the time zone settings."
|
|
::= { wtWebGraphAnalog57762DeviceClock 4 }
|
|
|
|
wtWebGraphAnalog57762ClockYear OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Date: Year, taking into account the time zone settings."
|
|
::= { wtWebGraphAnalog57762DeviceClock 5 }
|
|
|
|
|
|
-- wtWebGraphAnalog57762Network Group
|
|
------------------------
|
|
|
|
wtWebGraphAnalog57762IpAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the Webio"
|
|
::= { wtWebGraphAnalog57762Network 1 }
|
|
|
|
wtWebGraphAnalog57762SubnetMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subnet mask of the Webio"
|
|
::= { wtWebGraphAnalog57762Network 2 }
|
|
|
|
wtWebGraphAnalog57762Gateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Gateway of the Webio"
|
|
::= { wtWebGraphAnalog57762Network 3 }
|
|
|
|
wtWebGraphAnalog57762DnsServer1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 1st DNS server in ASCII"
|
|
::= { wtWebGraphAnalog57762Network 4 }
|
|
|
|
wtWebGraphAnalog57762DnsServer2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the 2nd DNS server in ASCII"
|
|
::= { wtWebGraphAnalog57762Network 5 }
|
|
|
|
wtWebGraphAnalog57762AddConfig OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Additional configuration (1=ON):
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: DHCP disable
|
|
Bit 0: BOOTP disable
|
|
"
|
|
::= { wtWebGraphAnalog57762Network 6 }
|
|
|
|
-- wtWebGraphAnalog57762HTTP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762Startup OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded start page:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1: Index.htm
|
|
Bit 2: Home.htm
|
|
Bit 3: User.htm
|
|
Only one page may be selected at a time."
|
|
::= { wtWebGraphAnalog57762HTTP 1 }
|
|
|
|
wtWebGraphAnalog57762GetHeaderEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If these bits are set, every answer of a short form GET question will be lead
|
|
by the IP-address and name of the device and/or a HTTP header:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-6: unused
|
|
Bit 1 : GET HTTP enable
|
|
Bit 0 : GET Header enable"
|
|
::= { wtWebGraphAnalog57762HTTP 2 }
|
|
|
|
wtWebGraphAnalog57762HttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Definition of the standard HTML port (Default: 80)."
|
|
::= { wtWebGraphAnalog57762HTTP 3 }
|
|
|
|
|
|
-- wtWebGraphAnalog57762Mail Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762MailAdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Device name for mail administration."
|
|
::= { wtWebGraphAnalog57762Mail 1 }
|
|
|
|
wtWebGraphAnalog57762MailReply OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reply address for the mail server."
|
|
::= { wtWebGraphAnalog57762Mail 2 }
|
|
|
|
wtWebGraphAnalog57762MailServer OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the mail server."
|
|
::= { wtWebGraphAnalog57762Mail 3 }
|
|
|
|
wtWebioAn1MailEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable the sending of mails:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Mail enable"
|
|
::= { wtWebGraphAnalog57762Mail 4 }
|
|
|
|
wtWebGraphAnalog57762MailAuthentication OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the authentication modi:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : POP3 before SMTP
|
|
Bit 1 : ESMTP, authentication
|
|
Bit 0 : SMTP, no authentication"
|
|
::= { wtWebGraphAnalog57762Mail 5 }
|
|
|
|
wtWebGraphAnalog57762MailAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the user to be authenticated."
|
|
::= { wtWebGraphAnalog57762Mail 6 }
|
|
|
|
wtWebGraphAnalog57762MailAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Authentication password."
|
|
::= { wtWebGraphAnalog57762Mail 7 }
|
|
|
|
wtWebGraphAnalog57762MailPop3Server OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or Ip-address of the POP3 Servers."
|
|
::= { wtWebGraphAnalog57762Mail 8 }
|
|
|
|
-- wtWebGraphAnalog57762SNMP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762SnmpCommunityStringRead OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read only"
|
|
::= { wtWebGraphAnalog57762SNMP 1 }
|
|
|
|
wtWebGraphAnalog57762SnmpCommunityStringReadWrite OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string read / write"
|
|
::= { wtWebGraphAnalog57762SNMP 2 }
|
|
|
|
wtWebGraphAnalog57762SystemTrapManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the system trap."
|
|
::= { wtWebGraphAnalog57762SNMP 3 }
|
|
|
|
wtWebGraphAnalog57762SystemTrapEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762SNMP 4 }
|
|
|
|
wtWebGraphAnalog57762SnmpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0 to enable SNMP.
|
|
If disabled, the device did not respond to any SNMP requests.
|
|
Bit 1 decided wether the community string of read operations
|
|
is compared with the system password or not:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : SNMP enable"
|
|
::= { wtWebGraphAnalog57762SNMP 5 }
|
|
|
|
wtWebGraphAnalog57762SnmpCommunityStringTrap OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Community string send within traps."
|
|
::= { wtWebGraphAnalog57762SNMP 6 }
|
|
|
|
wtWebGraphAnalog57762SnmpSystemTrapManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the system trap."
|
|
::= { wtWebGraphAnalog57762SNMP 7 }
|
|
|
|
|
|
-- wtWebGraphAnalog57762UDP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762UdpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Udp port to which the Udp queries ( short form GET requests) can be sent. This
|
|
port number must be unique within the device."
|
|
::= { wtWebGraphAnalog57762UDP 1 }
|
|
|
|
wtWebGraphAnalog57762UdpEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set this bit to enable UDP support:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : UDP enable"
|
|
::= { wtWebGraphAnalog57762UDP 2 }
|
|
|
|
-- wtWebGraphAnalog57762Syslog Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762SyslogServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the Syslog server, which accepts the Syslog messgaes."
|
|
::= { wtWebGraphAnalog57762Syslog 1 }
|
|
|
|
wtWebGraphAnalog57762SyslogServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the Syslog servers, default 514."
|
|
::= { wtWebGraphAnalog57762Syslog 2 }
|
|
|
|
wtWebGraphAnalog57762SyslogSystemMessagesEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: ColdStart
|
|
Bit 1: WarmStart
|
|
Bit 2: Diag Messages
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphAnalog57762Syslog 3 }
|
|
|
|
wtWebGraphAnalog57762SyslogEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set bit 0to enable Syslog:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Syslog enable"
|
|
::= { wtWebGraphAnalog57762Syslog 4 }
|
|
|
|
-- wtWebGraphAnalog57762FTP Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762FTPServerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the FTP server, which accepts the FTP messages."
|
|
::= { wtWebGraphAnalog57762FTP 1 }
|
|
|
|
wtWebGraphAnalog57762FTPServerControlPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Portnumber of the control port of the FTP server, default 21."
|
|
::= { wtWebGraphAnalog57762FTP 2 }
|
|
|
|
wtWebGraphAnalog57762FTPUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user name."
|
|
::= { wtWebGraphAnalog57762FTP 3 }
|
|
|
|
wtWebGraphAnalog57762FTPPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: user password."
|
|
::= { wtWebGraphAnalog57762FTP 4 }
|
|
|
|
wtWebGraphAnalog57762FTPAccount OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"FTP Loggin: name of account."
|
|
::= { wtWebGraphAnalog57762FTP 5 }
|
|
|
|
wtWebGraphAnalog57762FTPOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 switches the FTP Server in Passiv-Mode,
|
|
the Client controls the data connection on its own:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : PASV enable"
|
|
::= { wtWebGraphAnalog57762FTP 6 }
|
|
|
|
wtWebGraphAnalog57762FTPEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Set Bit 0 to enable FTP:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : FTP enable"
|
|
::= { wtWebGraphAnalog57762FTP 7 }
|
|
|
|
-- wtWebGraphAnalog57762Language Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762LanguageSelect OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Language selection:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 2-7: unused
|
|
Bit 1 : English
|
|
Bit 0 : German"
|
|
::= { wtWebGraphAnalog57762Language 1 }
|
|
|
|
-- wtWebGraphAnalog57762Binary Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762BinaryModeCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent binary channels."
|
|
::= { wtWebGraphAnalog57762Binary 1 }
|
|
|
|
-- Binary Interface Table
|
|
|
|
wtWebGraphAnalog57762BinaryIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of indices."
|
|
::= { wtWebGraphAnalog57762Binary 2 }
|
|
|
|
wtWebGraphAnalog57762BinaryIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762BinaryIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Indices of the binary channels."
|
|
INDEX { wtWebGraphAnalog57762BinaryModeNo }
|
|
::= { wtWebGraphAnalog57762BinaryIfTable 1 }
|
|
|
|
WtWebGraphAnalog57762BinaryIfEntry ::= SEQUENCE {
|
|
wtWebGraphAnalog57762BinaryModeNo INTEGER
|
|
}
|
|
|
|
wtWebGraphAnalog57762BinaryModeNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..2)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of the binary channel."
|
|
::= { wtWebGraphAnalog57762BinaryIfEntry 1 }
|
|
|
|
-- Binary Table
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762BinaryTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Table of properties of the binary mode."
|
|
::= { wtWebGraphAnalog57762Binary 3 }
|
|
|
|
wtWebGraphAnalog57762BinaryEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762BinaryEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary properties."
|
|
INDEX { wtWebGraphAnalog57762BinaryModeNo }
|
|
::= { wtWebGraphAnalog57762BinaryTable 1 }
|
|
|
|
WtWebGraphAnalog57762BinaryEntry ::= SEQUENCE {
|
|
wtWebGraphAnalog57762BinaryOperationMode OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpServerLocalPort INTEGER,
|
|
wtWebGraphAnalog57762BinaryTcpServerInputTrigger OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpServerApplicationMode OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpClientLocalPort INTEGER,
|
|
wtWebGraphAnalog57762BinaryTcpClientServerPort INTEGER,
|
|
wtWebGraphAnalog57762BinaryTcpClientServerIpAddr OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpClientServerPassword OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpClientInactivity INTEGER,
|
|
wtWebGraphAnalog57762BinaryTcpClientInputTrigger OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpClientInterval INTEGER,
|
|
wtWebGraphAnalog57762BinaryTcpClientApplicationMode OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryUdpPeerLocalPort INTEGER,
|
|
wtWebGraphAnalog57762BinaryUdpPeerRemotePort INTEGER,
|
|
wtWebGraphAnalog57762BinaryUdpPeerRemoteIpAddr OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryUdpPeerInputTrigger OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryUdpPeerInterval INTEGER,
|
|
wtWebGraphAnalog57762BinaryUdpPeerApplicationMode OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryConnectedPort INTEGER,
|
|
wtWebGraphAnalog57762BinaryConnectedIpAddr IpAddress,
|
|
wtWebGraphAnalog57762BinaryTcpServerClientHttpPort INTEGER,
|
|
wtWebGraphAnalog57762BinaryTcpClientServerHttpPort INTEGER,
|
|
wtWebGraphAnalog57762BinaryTcpServerHysteresis1 OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpServerHysteresis2 OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpClientHysteresis1 OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpClientHysteresis2 OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryUdpPeerHysteresis1 OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryUdpPeerHysteresis2 OCTET STRING,
|
|
wtWebGraphAnalog57762BinaryTcpClientServerUserName OCTET STRING
|
|
}
|
|
|
|
wtWebGraphAnalog57762BinaryOperationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the operation mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : UDP Peer
|
|
Bit 1 : TCP Client
|
|
Bit 0 : TCP Server"
|
|
::= { wtWebGraphAnalog57762BinaryEntry 1 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpServerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this server mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 2 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpServerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input states.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Analog inputs 0-1"
|
|
::= { wtWebGraphAnalog57762BinaryEntry 3 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpServerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 4-7: unused
|
|
Bit 3 : OPC Device
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebGraphAnalog57762BinaryEntry 4 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local TCP port for data exchange in this client mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 5 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server port to zero."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 6 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientServerIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the server. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the server IP address to 0.0.0.0."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 7 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientServerPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by the
|
|
administrator password of the server. Enter the server password
|
|
to establish the connection, if a server administrator password
|
|
exists."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 8 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientInactivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Connection timeout in 100ms. If no data are exchanged within the specified
|
|
time, the device closes the connection to the server.
|
|
The value 0 deactivates the timer. Using the Box2Box mode this function is
|
|
disabled."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 9 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input states.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Analog inputs 0-1"
|
|
::= { wtWebGraphAnalog57762BinaryEntry 10 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured application. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 11 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit,
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebGraphAnalog57762BinaryEntry 12 }
|
|
|
|
wtWebGraphAnalog57762BinaryUdpPeerLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local UDP port for data exchange in this peer to peer mode.
|
|
This port number must be unique within the device.
|
|
Reserved port number must not be used (refere to the manual)."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 13 }
|
|
|
|
wtWebGraphAnalog57762BinaryUdpPeerRemotePort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote port to zero."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 14 }
|
|
|
|
wtWebGraphAnalog57762BinaryUdpPeerRemoteIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ip address of the remote device. A complete set of port number, IP address
|
|
and a valid input/output mask starts this mode.
|
|
No data exchange take place when setting the remote device IP address to 0.0.0.0."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 15 }
|
|
|
|
wtWebGraphAnalog57762BinaryUdpPeerInputTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every change on the inputs causes their state to be transmitted to the
|
|
remote device. To minimize data traffic, individual inputs may be exempted
|
|
from this rule. Nevertheless every transmission will contain all input states.
|
|
If a bit is set (1), a change of state on the corresponding input
|
|
triggers a transmission. If the bit is not set (0), no transmission
|
|
takes place.
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an input.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 0-1: Analog inputs 0-1"
|
|
::= { wtWebGraphAnalog57762BinaryEntry 16 }
|
|
|
|
wtWebGraphAnalog57762BinaryUdpPeerInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (0..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Configurable interval with a 100ms base, in which the Webio device sends
|
|
data to the configured remote device. A interval of zero stopps the
|
|
periodical sending."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 17 }
|
|
|
|
wtWebGraphAnalog57762BinaryUdpPeerApplicationMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Selection of the application mode:
|
|
The OCTETS are interpreted bit-by-bit, with each bit corresponding to an output.
|
|
Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : Box2Box Slave
|
|
Bit 1 : Compatible 50xxx
|
|
Bit 0 : Default"
|
|
::= { wtWebGraphAnalog57762BinaryEntry 18 }
|
|
|
|
wtWebGraphAnalog57762BinaryConnectedPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations a zero will be read."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 19 }
|
|
|
|
wtWebGraphAnalog57762BinaryConnectedIpAddr OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the remote device, after connection has been established.
|
|
In case of no connection or missing port informations 0.0.0.0 will be read."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 20 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpServerClientHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Server Mode. If an mailfunction occurs
|
|
status informations will be send to this port.
|
|
Not used at mode Compatible 50xxx."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 21 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientServerHttpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP port number of the remote device at TCP Client Mode. In the operating mode
|
|
Box2Box connection status informations will be exchanged through this port."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 22 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpServerHysteresis1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A change greater than this value initiate a transmission of the corresponding input value.
|
|
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger.
|
|
With a hysteresis of zero any change will be transmitted."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 23 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpServerHysteresis2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A change greater than this value initiate a transmission of the corresponding input value.
|
|
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpServerInputTrigger.
|
|
With a hysteresis of zero any change will be transmitted."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 24 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientHysteresis1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A change greater than this value initiate a transmission of the corresponding input value.
|
|
The input 1 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger.
|
|
With a hysteresis of zero any change will be transmitted."
|
|
|
|
::= { wtWebGraphAnalog57762BinaryEntry 25 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientHysteresis2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A change greater than this value initiate a transmission of the corresponding input value.
|
|
The input 2 must be selected at wtWebGraphAnalog57762BinaryTcpClientInputTrigger.
|
|
With a hysteresis of zero any change will be transmitted."
|
|
|
|
::= { wtWebGraphAnalog57762BinaryEntry 26 }
|
|
|
|
wtWebGraphAnalog57762BinaryUdpPeerHysteresis1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A change greater than this value initiate a transmission of the corresponding input value.
|
|
The input 1 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger.
|
|
With a hysteresis of zero any change will be transmitted."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 27 }
|
|
|
|
wtWebGraphAnalog57762BinaryUdpPeerHysteresis2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"A change greater than this value initiate a transmission of the corresponding input value.
|
|
The input 2 must be selected at wtWebGraphAnalog57762BinaryUdpPeerInputTrigger.
|
|
With a hysteresis of zero any change will be transmitted."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 28 }
|
|
|
|
wtWebGraphAnalog57762BinaryTcpClientServerUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Building a connection may be protected by a specific
|
|
user name within the server. Enter the user name
|
|
to establish the connection, if a user name entry
|
|
exists."
|
|
::= { wtWebGraphAnalog57762BinaryEntry 29 }
|
|
|
|
-- wtWebGraphAnalog57762MQTT Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762MQTTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 7 schaltet MQTT frei:
|
|
Octet 1: ungenutzt
|
|
Octet 2: ungenutzt
|
|
Octet 3: ungenutzt
|
|
Octet 4:
|
|
Bit 0-6: ungenutzt
|
|
Bit 7 : MQTT enable"
|
|
::= { wtWebGraphAnalog57762MQTT 1 }
|
|
|
|
wtWebGraphAnalog57762MQTTBrockerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP-address of the MQTT-Server."
|
|
::= { wtWebGraphAnalog57762MQTT 2 }
|
|
|
|
wtWebGraphAnalog57762MQTTUserName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login user name."
|
|
::= { wtWebGraphAnalog57762MQTT 3 }
|
|
|
|
wtWebGraphAnalog57762MQTTPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT login password."
|
|
::= { wtWebGraphAnalog57762MQTT 4 }
|
|
|
|
wtWebGraphAnalog57762MQTTLocalPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local port number."
|
|
::= { wtWebGraphAnalog57762MQTT 5 }
|
|
|
|
wtWebGraphAnalog57762MQTTBrokerServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Server port number."
|
|
::= { wtWebGraphAnalog57762MQTT 6 }
|
|
|
|
wtWebGraphAnalog57762MQTTInterval OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Ping intervall, if no data has to be send: time in seconds."
|
|
::= { wtWebGraphAnalog57762MQTT 7 }
|
|
|
|
wtWebGraphAnalog57762MQTTLastWillEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will enable"
|
|
::= { wtWebGraphAnalog57762MQTT 8 }
|
|
|
|
wtWebGraphAnalog57762MQTTLastWillTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Topic."
|
|
::= { wtWebGraphAnalog57762MQTT 9 }
|
|
|
|
wtWebGraphAnalog57762MQTTLastWillMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will message."
|
|
::= { wtWebGraphAnalog57762MQTT 10 }
|
|
|
|
wtWebGraphAnalog57762MQTTLastWillQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish QoS:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebGraphAnalog57762MQTT 11 }
|
|
|
|
wtWebGraphAnalog57762MQTTLastWillRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded MQTT Publish Retain properties:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebGraphAnalog57762MQTT 12 }
|
|
|
|
wtWebGraphAnalog57762MQTTLastWillConnectEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activate MQTT LastWill Connect message:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : MQTT Last will connect message enable"
|
|
::= { wtWebGraphAnalog57762MQTT 13 }
|
|
|
|
wtWebGraphAnalog57762MQTTLastWillConnectMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Last Will Connect message will be send with the QoS and Retain settings
|
|
of the LastWill message."
|
|
::= { wtWebGraphAnalog57762MQTT 14 }
|
|
|
|
-- wtWebGraphAnalog57762REST Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762RESTEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates REST :
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : REST enable"
|
|
::= { wtWebGraphAnalog57762REST 1 }
|
|
|
|
wtWebGraphAnalog57762RESTDigestAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Bit 0 activates Digest-Authentification:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 1-7: unused
|
|
Bit 0 : Digest Auth enable"
|
|
::= { wtWebGraphAnalog57762REST 2 }
|
|
|
|
-- wtWebGraphAnalog57762Datalogger Group
|
|
--------------------------------
|
|
|
|
wtWebGraphAnalog57762LoggerTimebase OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
wtWebGraphAnalog57762Datalogger-15Sec(1),
|
|
wtWebGraphAnalog57762Datalogger-30Sec(2),
|
|
wtWebGraphAnalog57762Datalogger-1Min(3),
|
|
wtWebGraphAnalog57762Datalogger-5Min(4),
|
|
wtWebGraphAnalog57762Datalogger-15Min(5),
|
|
wtWebGraphAnalog57762Datalogger-60Min(6)
|
|
}
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Time base of the data logger"
|
|
::= { wtWebGraphAnalog57762Datalogger 1 }
|
|
|
|
wtWebGraphAnalog57762LoggerSensorSel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762Datalogger 2 }
|
|
|
|
-- wtWebGraphAnalog57762Alarm Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762AlarmCount OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of independent alarms."
|
|
::= { wtWebGraphAnalog57762Alarm 1 }
|
|
|
|
-- Alarm Interface Table
|
|
|
|
wtWebGraphAnalog57762AlarmIfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of alarm indices."
|
|
::= { wtWebGraphAnalog57762Alarm 2 }
|
|
|
|
wtWebGraphAnalog57762AlarmIfEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762AlarmIfEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the alarms."
|
|
INDEX { wtWebGraphAnalog57762AlarmNo }
|
|
::= { wtWebGraphAnalog57762AlarmIfTable 1 }
|
|
|
|
WtWebGraphAnalog57762AlarmIfEntry ::= SEQUENCE {
|
|
wtWebGraphAnalog57762AlarmNo INTEGER
|
|
}
|
|
|
|
wtWebGraphAnalog57762AlarmNo OBJECT-TYPE
|
|
SYNTAX INTEGER (1..8)
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm number."
|
|
::= { wtWebGraphAnalog57762AlarmIfEntry 1 }
|
|
|
|
-- Alarm Table
|
|
|
|
wtWebGraphAnalog57762AlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the alarm number."
|
|
::= { wtWebGraphAnalog57762Alarm 3 }
|
|
|
|
wtWebGraphAnalog57762AlarmEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762AlarmEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm parameters of the individual alarms."
|
|
INDEX { wtWebGraphAnalog57762AlarmNo }
|
|
::= { wtWebGraphAnalog57762AlarmTable 1 }
|
|
|
|
WtWebGraphAnalog57762AlarmEntry ::= SEQUENCE {
|
|
wtWebGraphAnalog57762AlarmTrigger OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMin1 OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMax1 OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmHysteresis1 OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmDelay OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmInterval OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmEnable OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmEMailAddr OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMailSubject OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMailText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmManagerIP OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmTrapText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMailOptions OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmTcpIpAddr OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmTcpPort INTEGER,
|
|
wtWebGraphAnalog57762AlarmTcpText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmClearMailSubject OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmClearMailText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmClearTrapText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmClearTcpText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMin2 OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMax2 OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmHysteresis2 OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmSyslogIpAddr OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmSyslogPort INTEGER,
|
|
wtWebGraphAnalog57762AlarmSyslogText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmSyslogClearText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmFtpDataPort OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmFtpFileName OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmFtpText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmFtpClearText OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmFtpOption OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmTimerCron OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmDeltaTemp OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmName OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmActive OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmHttpReqAuthEnable OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmHttpReqAuthUser OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmHttpReqAuthPassword OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmHttpReqSetUrl OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmHttpReqClearUrl OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmHttpReqServerPort INTEGER,
|
|
wtWebGraphAnalog57762AlarmMqttTopicPath OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMqttTopicSetTopic OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMqttTopicClear OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmSensorLostSelection OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmLimitWindow OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmSnmpManagerPort INTEGER,
|
|
wtWebGraphAnalog57762AlarmMqttQoS OCTET STRING,
|
|
wtWebGraphAnalog57762AlarmMqttRetain OCTET STRING
|
|
|
|
}
|
|
|
|
wtWebGraphAnalog57762AlarmTrigger OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded trigger conditions:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3:
|
|
Bit 0: Timer
|
|
Bit 1: ColdStart
|
|
Bit 2: WarmStart
|
|
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 1 }
|
|
|
|
wtWebGraphAnalog57762AlarmMin1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum sensor 1 with maximum 3 decimal places."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 2 }
|
|
|
|
wtWebGraphAnalog57762AlarmMax1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum sensor 1 with maximum 3 decimal places."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 3 }
|
|
|
|
wtWebGraphAnalog57762AlarmHysteresis1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Reading changes of this size clears the alarm state (MAX-hyst, MIN+hyst.)
|
|
with maximum 3 decimal places."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 4 }
|
|
|
|
wtWebGraphAnalog57762AlarmDelay OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm will be delayed by setting this time while stable alarm
|
|
condition occur (time in minutes)."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 5 }
|
|
|
|
|
|
wtWebGraphAnalog57762AlarmInterval OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Send interval for alarm messages."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 6 }
|
|
|
|
wtWebGraphAnalog57762AlarmEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded alarm enable:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Mail Enable
|
|
Bit 1: SNMP Trap enable
|
|
Bit 2: TCP Client enable"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 7 }
|
|
|
|
wtWebGraphAnalog57762AlarmEMailAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"E-Mail address for sending the alarm mail to."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 8 }
|
|
|
|
wtWebGraphAnalog57762AlarmMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm mail."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 9 }
|
|
|
|
wtWebGraphAnalog57762AlarmMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm mail text: <Mn> provides the current temperature; n = 1..2.
|
|
<Z> provides the current time."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 10 }
|
|
|
|
wtWebGraphAnalog57762AlarmManagerIP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the SNMP Manager which accepts the trap."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 11 }
|
|
|
|
wtWebGraphAnalog57762AlarmTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the trap body."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 12 }
|
|
|
|
wtWebGraphAnalog57762AlarmMailOptions OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Attach Thermo.csv Enable
|
|
Bit 1 : CSV-Data_since_last_report
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 13 }
|
|
|
|
wtWebGraphAnalog57762AlarmTcpIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name or IP address of the TCP server which accepts the trap."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 14 }
|
|
|
|
wtWebGraphAnalog57762AlarmTcpPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the TCP server which accepts the trap."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 15 }
|
|
|
|
wtWebGraphAnalog57762AlarmTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the TCP trap body."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 16 }
|
|
|
|
wtWebGraphAnalog57762AlarmClearMailSubject OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Subject line for alarm clear mail."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 17 }
|
|
|
|
wtWebGraphAnalog57762AlarmClearMailText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm clear mail text: <Mn> provides the current temperature; n = 1..2.
|
|
<Z> provides the current time."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 18 }
|
|
|
|
wtWebGraphAnalog57762AlarmClearTrapText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the trap body."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 19 }
|
|
|
|
wtWebGraphAnalog57762AlarmClearTcpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This text is sent in the TCP trap body."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 20 }
|
|
|
|
wtWebGraphAnalog57762AlarmMin2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Minimum sensor 2 with maximum 3 decimal places."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 21 }
|
|
|
|
wtWebGraphAnalog57762AlarmMax2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Maximum sensor 2 with maximum 2 decimal places."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 22 }
|
|
|
|
wtWebGraphAnalog57762AlarmHysteresis2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Hysterese rel. sensor 2 with maximum 3 decimal places."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 23 }
|
|
|
|
wtWebGraphAnalog57762AlarmSyslogIpAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"IP address of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 24 }
|
|
|
|
wtWebGraphAnalog57762AlarmSyslogPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the syslog server to which the Webio device should send syslog messages."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 25 }
|
|
|
|
wtWebGraphAnalog57762AlarmSyslogText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 26 }
|
|
|
|
wtWebGraphAnalog57762AlarmSyslogClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Every message starts with the priority key, a time stamp and the host ip address, according RFC3164.
|
|
This text appears in the following syslog message body of a alarm clear message."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 27 }
|
|
|
|
wtWebGraphAnalog57762AlarmFtpDataPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Local data port: 1..65535 or AUTO: the next free port will be assigned."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 28 }
|
|
|
|
wtWebGraphAnalog57762AlarmFtpFileName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the file including path informations."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 29 }
|
|
|
|
wtWebGraphAnalog57762AlarmFtpText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Message text to store on the FTP server."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 30 }
|
|
|
|
wtWebGraphAnalog57762AlarmFtpClearText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alarm clear message to store on the FTP server."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 31 }
|
|
|
|
wtWebGraphAnalog57762AlarmFtpOption OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
STORE = replace file
|
|
APPEND = append message at the end of the file
|
|
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : STORE
|
|
Bit 1 : APPEND
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 32 }
|
|
|
|
wtWebGraphAnalog57762AlarmTimerCron OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This entry defines a time window for alarm 1-8 and a activation time for the report.
|
|
A time window is definied by start and stop time stamp, seperated by a space or tab.
|
|
The activation time of the report is defined by a single start time stamp.
|
|
Each time stamp contains 5 space or tab seperated text fields for time trigger definition.
|
|
Each field must match with the actual time to trigger an action, weekday and day of month
|
|
are interpreted separatley.
|
|
1: Minutes Range 0-59
|
|
2. Hours Range 0-23, 0 is midnight
|
|
3: Day of month Range 1-31
|
|
4: Month Range 1-12
|
|
5: Weekday Range 0-6, 0 is sunday
|
|
|
|
Syntax for every field:
|
|
- an asterix (*) enables every possible setting of a field
|
|
- single numbers seperated by commas (i.e.: 2,14,22)
|
|
- a partition within the allowed range (i.e.: 1-5)
|
|
- step size within a partition of the allowed range (i.e.: 0-59/2 every second minute)."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 33 }
|
|
|
|
-- __JB__
|
|
wtWebGraphAnalog57762AlarmName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alert name"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 39 }
|
|
|
|
-- __JB__
|
|
wtWebGraphAnalog57762AlarmActive OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Alert active
|
|
1 = ON
|
|
0 = OFF"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 40 }
|
|
|
|
wtWebGraphAnalog57762AlarmHttpReqAuthEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options, select only one option at the same time:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : HHTP Request Authentication enable"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 61 }
|
|
|
|
wtWebGraphAnalog57762AlarmHttpReqAuthUser OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: User"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 62 }
|
|
|
|
wtWebGraphAnalog57762AlarmHttpReqAuthPassword OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Password"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 63 }
|
|
|
|
wtWebGraphAnalog57762AlarmHttpReqSetUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Set URL"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 64 }
|
|
|
|
wtWebGraphAnalog57762AlarmHttpReqClearUrl OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Clear URL"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 65 }
|
|
|
|
wtWebGraphAnalog57762AlarmHttpReqServerPort OBJECT-TYPE
|
|
SYNTAX INTEGER (1..65535)
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"HTTP Request: Server Port"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 66 }
|
|
|
|
wtWebGraphAnalog57762AlarmMqttTopicPath OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic path"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 67 }
|
|
|
|
wtWebGraphAnalog57762AlarmMqttTopicSetTopic OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic SET message"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 68 }
|
|
|
|
wtWebGraphAnalog57762AlarmMqttTopicClear OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"MQTT Publish: Topic CLEAR message"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 69 }
|
|
|
|
wtWebGraphAnalog57762AlarmSensorLostSelection OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 1-7: unused
|
|
Bit 0 : Sensor 0"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 70 }
|
|
|
|
wtWebGraphAnalog57762AlarmLimitWindow OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"If window type is INSIDE the alarm is genereted when the temperature
|
|
is greater minumum value and lower than maximum value. If window type is OUTSIDE
|
|
the alarm is generated when the measured value is lower than the minimum value
|
|
or greater than the maximum value.
|
|
Binary coded options, select only one option at the same time:
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4, Bit 2-7: unused
|
|
Bit 1 : inside window
|
|
Bit 0 : outside window"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 71 }
|
|
|
|
wtWebGraphAnalog57762AlarmSnmpManagerPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Port number of the SNMP Manager to which the Webio device should send SNMP traps."
|
|
::= { wtWebGraphAnalog57762AlarmEntry 76 }
|
|
|
|
wtWebGraphAnalog57762AlarmMqttQoS OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: QoS 0
|
|
Bit 1: QoS 1
|
|
Bit 2: QoS 2
|
|
Bit 3-7:unused"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 77 }
|
|
|
|
wtWebGraphAnalog57762AlarmMqttRetain OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded value:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : retain enable
|
|
Bit 1-7 : unused"
|
|
::= { wtWebGraphAnalog57762AlarmEntry 78 }
|
|
|
|
-- wtWebGraphAnalog57762GraphicsBase Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762GraphicsBaseEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the viewing options of the graphic:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Auto scroll enable
|
|
Bit 1 : Show table
|
|
Bit 2 : Show graph
|
|
Bit 3 : Show control buttons
|
|
Bit 4 : Show config menu
|
|
Bit 5-7: unused"
|
|
::= { wtWebGraphAnalog57762GraphicsBase 1 }
|
|
|
|
wtWebGraphAnalog57762GraphicsBaseWidth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the width of the graphic in pixels."
|
|
::= { wtWebGraphAnalog57762GraphicsBase 2 }
|
|
|
|
wtWebGraphAnalog57762GraphicsBaseHeight OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the height of the graphic in pixels."
|
|
::= { wtWebGraphAnalog57762GraphicsBase 3 }
|
|
|
|
wtWebGraphAnalog57762GraphicsBaseFrameColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Frame color definition in RGB."
|
|
::= { wtWebGraphAnalog57762GraphicsBase 4 }
|
|
|
|
wtWebGraphAnalog57762GraphicsBaseBackgroundColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Background color definition in RGB."
|
|
::= { wtWebGraphAnalog57762GraphicsBase 5 }
|
|
|
|
wtWebGraphAnalog57762GraphicsBasePollingrate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Defines the pollingrate in seconds,
|
|
which defines the refreshing intervall of the graphic."
|
|
::= { wtWebGraphAnalog57762GraphicsBase 6 }
|
|
|
|
-- wtWebGraphAnalog57762GraphicsSelect Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762GraphicsSelectDisplaySensorSel OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded sensor selection:
|
|
only selected sensors will be shown in the graphical presentation:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762GraphicsSelect 1 }
|
|
|
|
wtWebGraphAnalog57762GraphicsSelectDisplayShowExtrem OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded sensor selection:
|
|
only selected sensors will be shown with minima and maxima:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0: Sensor 1
|
|
Bit 1: Sensor 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762GraphicsSelect 2 }
|
|
|
|
-- Graph Sensor Color Table
|
|
|
|
wtWebGraphAnalog57762SensorColor2Table OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762SensorColor2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of sensor colors for the praphical presentation."
|
|
::= { wtWebGraphAnalog57762GraphicsSelect 3 }
|
|
|
|
wtWebGraphAnalog57762SensorColor2Entry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762SensorColor2Entry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Numbers of the sensors."
|
|
INDEX { wtWebGraphAnalog57762SensorNo }
|
|
::= { wtWebGraphAnalog57762SensorColor2Table 1 }
|
|
|
|
WtWebGraphAnalog57762SensorColor2Entry ::= SEQUENCE {
|
|
wtWebGraphAnalog57762GraphicsSensorColor OCTET STRING,
|
|
wtWebGraphAnalog57762GraphicsSelectScale OCTET STRING
|
|
}
|
|
|
|
wtWebGraphAnalog57762GraphicsSensorColor OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(3))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Color of the sensors at the praphical presention."
|
|
::= { wtWebGraphAnalog57762SensorColor2Entry 1 }
|
|
|
|
wtWebGraphAnalog57762GraphicsSelectScale OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Assignes one of 4 scales to a sensor:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Use Scale 1
|
|
Bit 1 : Use Scale 2
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762SensorColor2Entry 2 }
|
|
|
|
-- wtWebGraphAnalog57762GraphicsScale Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762GraphicsScaleAutoScaleEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Select the Auto Scale Mode:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Scale 1 Auto scale enable
|
|
Bit 1 : Scale 2 Auto scale enable
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762GraphicsScale 1 }
|
|
|
|
|
|
wtWebGraphAnalog57762GraphicsScaleAutoFitEnable OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Select the Auto Fit Mode::
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : Scale 1 Auto fit enable
|
|
Bit 1 : Scale 2 Auto fit enable
|
|
Bit 2-7: unused"
|
|
::= { wtWebGraphAnalog57762GraphicsScale 2 }
|
|
|
|
wtWebGraphAnalog57762GraphicsScale1Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Minimum."
|
|
::= { wtWebGraphAnalog57762GraphicsScale 3 }
|
|
|
|
wtWebGraphAnalog57762GraphicsScale2Min OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Minimum."
|
|
::= { wtWebGraphAnalog57762GraphicsScale 4 }
|
|
|
|
wtWebGraphAnalog57762GraphicsScale1Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Maximum."
|
|
::= { wtWebGraphAnalog57762GraphicsScale 7 }
|
|
|
|
wtWebGraphAnalog57762GraphicsScale2Max OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Maximum."
|
|
::= { wtWebGraphAnalog57762GraphicsScale 8 }
|
|
|
|
wtWebGraphAnalog57762GraphicsScale1Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 1: Unit."
|
|
::= { wtWebGraphAnalog57762GraphicsScale 11 }
|
|
|
|
wtWebGraphAnalog57762GraphicsScale2Unit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Scale 2: Unit."
|
|
::= { wtWebGraphAnalog57762GraphicsScale 12 }
|
|
|
|
-- wtWebGraphAnalog57762Ports Group
|
|
----------------------------
|
|
|
|
-- Table
|
|
|
|
wtWebGraphAnalog57762PortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF WtWebGraphAnalog57762PortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"List of settings depending on the sensor number."
|
|
::= { wtWebGraphAnalog57762Ports 1 }
|
|
|
|
wtWebGraphAnalog57762PortEntry OBJECT-TYPE
|
|
SYNTAX WtWebGraphAnalog57762PortEntry
|
|
ACCESS not-accessible
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Sensor parameters for the individual sensors."
|
|
INDEX { wtWebGraphAnalog57762SensorNo }
|
|
::= { wtWebGraphAnalog57762PortTable 1 }
|
|
|
|
WtWebGraphAnalog57762PortEntry ::= SEQUENCE {
|
|
wtWebGraphAnalog57762PortName OCTET STRING,
|
|
wtWebGraphAnalog57762PortText OCTET STRING,
|
|
wtWebGraphAnalog57762PortOffset1 OCTET STRING,
|
|
wtWebGraphAnalog57762SetPoint1 OCTET STRING,
|
|
wtWebGraphAnalog57762PortOffset2 OCTET STRING,
|
|
wtWebGraphAnalog57762SetPoint2 OCTET STRING,
|
|
wtWebGraphAnalog57762PortComment OCTET STRING,
|
|
wtWebGraphAnalog57762PortSensorSelect OCTET STRING,
|
|
wtWebGraphAnalog57762PortUnit OCTET STRING,
|
|
wtWebGraphAnalog57762PortScale0 OCTET STRING,
|
|
wtWebGraphAnalog57762PortScale100 OCTET STRING,
|
|
wtWebGraphAnalog57762PortOutputMode OCTET STRING,
|
|
wtWebGraphAnalog57762PortInputMode OCTET STRING,
|
|
wtWebGraphAnalog57762PortPresetValue OCTET STRING
|
|
}
|
|
|
|
wtWebGraphAnalog57762PortName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Name of the sensor."
|
|
::= { wtWebGraphAnalog57762PortEntry 1 }
|
|
|
|
wtWebGraphAnalog57762PortText OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Description of the sensor."
|
|
::= { wtWebGraphAnalog57762PortEntry 2 }
|
|
|
|
wtWebGraphAnalog57762PortOffset1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Offset in degrees with maximum 3 decimal places at set point 1."
|
|
::= { wtWebGraphAnalog57762PortEntry 3 }
|
|
|
|
wtWebGraphAnalog57762SetPoint1 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Reference set point 1 in degrees with maximum 3 decimal places."
|
|
::= { wtWebGraphAnalog57762PortEntry 4 }
|
|
|
|
wtWebGraphAnalog57762PortOffset2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Offset in degrees with maximum 3 decimal places at set point 2."
|
|
::= { wtWebGraphAnalog57762PortEntry 5 }
|
|
|
|
wtWebGraphAnalog57762SetPoint2 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: Reference set point 2 in degrees with maximum 3 decimal places."
|
|
::= { wtWebGraphAnalog57762PortEntry 6 }
|
|
|
|
wtWebGraphAnalog57762PortComment OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Offset calibration: informations of date, name of operator, reference devices."
|
|
::= { wtWebGraphAnalog57762PortEntry 7 }
|
|
|
|
wtWebGraphAnalog57762PortSensorSelect OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Binary coded options for sensor 1:
|
|
Octet 1: unused
|
|
Octet 2: unused
|
|
Octet 3: unused
|
|
Octet 4:
|
|
Bit 0 : 0-20mA (default)
|
|
Bit 1 : 4-20mA
|
|
Bit 2 : Disconnect
|
|
Bit 3-7: unused"
|
|
::= { wtWebGraphAnalog57762PortEntry 8 }
|
|
|
|
wtWebGraphAnalog57762PortUnit OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User scale: displayed unit."
|
|
::= { wtWebGraphAnalog57762PortEntry 9 }
|
|
|
|
wtWebGraphAnalog57762PortScale0 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User scale: displayed value in 1/1000 at 0% full scale range.
|
|
Range: -999999.999 to 999999.999"
|
|
::= { wtWebGraphAnalog57762PortEntry 10 }
|
|
|
|
wtWebGraphAnalog57762PortScale100 OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"User scale: displayed value in 1/1000 at 100% full scale range.
|
|
Range: -999999.999 to 999999.999"
|
|
::= { wtWebGraphAnalog57762PortEntry 11 }
|
|
|
|
wtWebGraphAnalog57762PortOutputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded output mode defines the individual operation mode for any
|
|
output. More than one mode must not be selected. If an output mode is selected,
|
|
Bit 2 in wtWebGraphAnalog57762PortInputMode will be set automatically.
|
|
The OCTETS are interpreted bit-by-bit, Bit 0 corresponds to the LSB.
|
|
OCTET 1: unused
|
|
OCTET 2: unused
|
|
OCTET 3: unused
|
|
OCTET 4: Bit 6-7: unused
|
|
Bit 5 : Output OFF
|
|
Bit 4 : Binary 2
|
|
Bit 3 : Binary 1
|
|
Bit 2 : SNMP
|
|
Bit 1 : UDP ASCII
|
|
Bit 0 : HTTP"
|
|
::= { wtWebGraphAnalog57762PortEntry 12 }
|
|
|
|
wtWebGraphAnalog57762PortInputMode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (4))
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This binary coded input mode defines the individual operation mode for any
|
|
input. More than one mode must not be selected. If an input mode is selected,
|
|
Bit 5 in wtWebGraphAnalog57762PortOutputMode will be set automatically.
|
|
The OCTETS are interpreted bit-by-bit,Bit 0 corresponds to the LSB.
|
|
OCTET 1: ungenutzt
|
|
OCTET 2: ungenutzt
|
|
OCTET 3: ungenutzt
|
|
OCTET 4: Bit 3-7: unused
|
|
Bit 2 : I-Output
|
|
Bit 1 : I-Input, active
|
|
Bit 0 : I-Input, passive"
|
|
::= { wtWebGraphAnalog57762PortEntry 13 }
|
|
|
|
wtWebGraphAnalog57762PortPresetValue OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"This value will be set after reset or initialisation."
|
|
::= { wtWebGraphAnalog57762PortEntry 16 }
|
|
|
|
-- wtWebGraphAnalog57762Manufact Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762MfName OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer company name"
|
|
::= { wtWebGraphAnalog57762Manufact 1 }
|
|
|
|
wtWebGraphAnalog57762MfAddr OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer address."
|
|
::= { wtWebGraphAnalog57762Manufact 2 }
|
|
|
|
wtWebGraphAnalog57762MfHotline OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer hotline."
|
|
::= { wtWebGraphAnalog57762Manufact 3 }
|
|
|
|
wtWebGraphAnalog57762MfInternet OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer Internet address."
|
|
::= { wtWebGraphAnalog57762Manufact 4 }
|
|
|
|
wtWebGraphAnalog57762MfDeviceTyp OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer device name (model number)."
|
|
::= { wtWebGraphAnalog57762Manufact 5 }
|
|
|
|
wtWebGraphAnalog57762MfOrderNo OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Manufacturer part number."
|
|
::= { wtWebGraphAnalog57762Manufact 6 }
|
|
|
|
-- wtWebGraphAnalog57762Diag Group
|
|
----------------------------
|
|
|
|
wtWebGraphAnalog57762DiagErrorCount OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Number of entries in the error memory."
|
|
::= { wtWebGraphAnalog57762Diag 1 }
|
|
|
|
wtWebGraphAnalog57762DiagBinaryError OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Error causes coded bit-by-bit."
|
|
::= { wtWebGraphAnalog57762Diag 2 }
|
|
|
|
wtWebGraphAnalog57762DiagErrorIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS read-write
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"The value of this variable is used as an index to read
|
|
an error massege from wtWebGraphAnalog57762DiagErrorMessage.
|
|
Errors are numbered from 1 to wtWebGraphAnalog57762DiagErrorCount.
|
|
Writing a valid value into this variable, making the appropriate
|
|
message readable from wtWebGraphAnalog57762DiagErrorMessage."
|
|
::= { wtWebGraphAnalog57762Diag 3 }
|
|
|
|
wtWebGraphAnalog57762DiagErrorMessage OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
ACCESS read-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Using wtWebGraphAnalog57762DiagErrorIndex as an index, the appropriate message is available."
|
|
::= { wtWebGraphAnalog57762Diag 4 }
|
|
|
|
wtWebGraphAnalog57762DiagErrorClear OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
ACCESS write-only
|
|
STATUS mandatory
|
|
DESCRIPTION
|
|
"Writing 1 into this variable clears all diagnosis messages."
|
|
::= { wtWebGraphAnalog57762Diag 5 }
|
|
|
|
-- TRAP DEFINITIONS
|
|
|
|
-- Diese SNMP-Traps werden gesendet, wenn die Alarmtriggerbedingungen zutreffen
|
|
|
|
wtWebGraphAnalog57762Alert1 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Alarm 1"
|
|
--#SUMMARY "Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 31
|
|
|
|
wtWebGraphAnalog57762Alert2 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Alarm 2"
|
|
--#SUMMARY "Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 32
|
|
|
|
wtWebGraphAnalog57762Alert3 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Alarm 3"
|
|
--#SUMMARY "Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 33
|
|
|
|
wtWebGraphAnalog57762Alert4 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Alarm 4"
|
|
--#SUMMARY "Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 34
|
|
|
|
wtWebGraphAnalog57762Alert5 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Alarm 5"
|
|
--#SUMMARY "Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 35
|
|
|
|
wtWebGraphAnalog57762Alert6 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Alarm 6"
|
|
--#SUMMARY "Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 36
|
|
|
|
wtWebGraphAnalog57762Alert7 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Alarm 7"
|
|
--#SUMMARY "Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 37
|
|
|
|
wtWebGraphAnalog57762Alert8 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Alarm 8"
|
|
--#SUMMARY "Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 38
|
|
|
|
wtWebGraphAnalog57762Alert9 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 1 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Release Alarm 1"
|
|
--#SUMMARY "Release Alarm 1: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 91
|
|
|
|
wtWebGraphAnalog57762Alert10 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 2 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Release Alarm 2"
|
|
--#SUMMARY "Release Alarm 2: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 92
|
|
|
|
wtWebGraphAnalog57762Alert11 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 3 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Release Alarm 3"
|
|
--#SUMMARY "Release Alarm 3: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 93
|
|
|
|
wtWebGraphAnalog57762Alert12 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 4 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Release Alarm 4"
|
|
--#SUMMARY "Release Alarm 4: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 94
|
|
|
|
wtWebGraphAnalog57762Alert13 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 5 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Release Alarm 5"
|
|
--#SUMMARY "Release Alarm 5: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 95
|
|
|
|
wtWebGraphAnalog57762Alert14 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 6 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Release Alarm 6"
|
|
--#SUMMARY "Release Alarm 6: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 96
|
|
|
|
wtWebGraphAnalog57762Alert15 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 7 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Release Alarm 7"
|
|
--#SUMMARY "Release Alarm 7: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 97
|
|
|
|
wtWebGraphAnalog57762Alert16 TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmClearTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when Alarm 8 was cleared,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Release Alarm 8"
|
|
--#SUMMARY "Release Alarm 8: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 98
|
|
|
|
wtWebGraphAnalog57762AlertReport TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES { wtWebGraphAnalog57762AlarmTrapText }
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when the report was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Report"
|
|
--#SUMMARY "Report: %s"
|
|
--#ARGUMENTS {0}
|
|
--#SEVERITY INFORMATIONAL
|
|
--#TIMEINDEX 99
|
|
--#STATE OPERATIONAL
|
|
::= 39
|
|
|
|
wtWebGraphAnalog57762AlertDiag TRAP-TYPE
|
|
ENTERPRISE wtWebGraphAnalog57762
|
|
VARIABLES {
|
|
wtWebGraphAnalog57762DiagErrorIndex,
|
|
wtWebGraphAnalog57762DiagErrorMessage
|
|
}
|
|
DESCRIPTION
|
|
"This SNMP trap is generated when a diagnosis/error message was triggered,
|
|
SNMP trap enable is set and
|
|
SNMP is enabled."
|
|
-- NMS trap annotation
|
|
--#TYPE "Web-IO Analog-InOut Diagnose Error"
|
|
--#SUMMARY "Diagnose error index: %d, Message: %s."
|
|
--#ARGUMENTS {0,1}
|
|
--#SEVERITY MAJOR
|
|
--#TIMEINDEX 99
|
|
--#STATE DEGRADED
|
|
::= 110
|
|
|
|