1619 lines
59 KiB
Plaintext
1619 lines
59 KiB
Plaintext
-- **********************************************************
|
|
-- Copyright 2016-2017 VMware, Inc. All rights reserved.
|
|
-- **********************************************************
|
|
|
|
VMWARE-VRNI-OLD-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
SnmpAdminString
|
|
FROM SNMP-FRAMEWORK-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION, DateAndTime
|
|
FROM SNMPv2-TC
|
|
vmwNetworkInsight
|
|
FROM VMWARE-ROOT-MIB
|
|
VmwLongSnmpAdminString
|
|
FROM VMWARE-TC-MIB;
|
|
|
|
vmwNetworkInsightMIB MODULE-IDENTITY
|
|
LAST-UPDATED "201709050000Z"
|
|
ORGANIZATION "VMware, Inc"
|
|
CONTACT-INFO
|
|
"VMware, Inc
|
|
3401 Hillview Ave
|
|
Palo Alto, CA 94304
|
|
Tel: 1-877-486-9273 or 650-427-5000
|
|
Fax: 650-427-5001
|
|
Web: http://kb.vmware.com/kb/1013445
|
|
"
|
|
DESCRIPTION
|
|
"WARNING: this is incompatible with current VRNI releases only for older systems to v3.5
|
|
so do not try to add both to one mgmt system.
|
|
This MIB module is for VMware vRealize Network Insight as described here:
|
|
https://www.vmware.com/support/pubs/vrealize-network-insight-pubs.html
|
|
"
|
|
|
|
REVISION "201709050000Z"
|
|
DESCRIPTION
|
|
"This is the fourth revsion of VMware vRealize Network Insight Manager SNMP notifications.
|
|
It adds fourteen new notifications, see vmwNetworkInsightNotificationGroup4.
|
|
"
|
|
|
|
REVISION "201706010000Z"
|
|
DESCRIPTION
|
|
"This is the third revsion of VMware vRealize Network Insight Manager SNMP notifications.
|
|
This version added nineteen new notifications, see vmwNetworkInsightNotificationGroup3
|
|
for complete listing."
|
|
|
|
REVISION "201702200000Z"
|
|
DESCRIPTION
|
|
"This is the second revision of VMware vRealize Network Insight Manager SNMP notifications.
|
|
It introduces new notifications, see vmwNetworkInsightNotificationGroup2,
|
|
and updates existing notifications to append the vmwEventName managed object."
|
|
|
|
REVISION "201610260000Z"
|
|
DESCRIPTION
|
|
"This is the first revision of VMware vRealize Network Insight Manager SNMP notifications."
|
|
::= { vmwNetworkInsight 1 }
|
|
|
|
vmwVRNIEvents OBJECT-IDENTITY
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"All notifications from vRealize Network Insight fall under this oid."
|
|
::= { vmwNetworkInsightMIB 0 }
|
|
|
|
vmwVRNIData OBJECT-IDENTITY
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"All variables that are sent in notifications fall under this oid."
|
|
::= { vmwNetworkInsightMIB 1 }
|
|
|
|
-- **********************************************************
|
|
-- Type definitions
|
|
-- **********************************************************
|
|
|
|
VmwVrniSeverity ::= TEXTUAL-CONVENTION
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Event Severity
|
|
For Problems, Major - Opens and alarms, Cleared Closes it
|
|
For Notifications - All are Info
|
|
"
|
|
SYNTAX INTEGER { cleared(0), info(1), major(2) }
|
|
|
|
|
|
-- **********************************************************
|
|
-- Notifications by an agent that implements this mib module
|
|
-- **********************************************************
|
|
|
|
vmwSnmpTrapsAreConfigured NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Initial trap to notify receiver that vRNI is now configured to send SNMP traps"
|
|
::= { vmwVRNIEvents 101}
|
|
|
|
|
|
vmwSnmpTrapsAreDisabled NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Trap to notify receiver that vRNI is no longer configured to send SNMP traps"
|
|
::= { vmwVRNIEvents 102}
|
|
|
|
vmwTestTrap NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Test Trap"
|
|
::= { vmwVRNIEvents 103}
|
|
|
|
vmwEntityDiscoveryChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Discovery Event"
|
|
::= { vmwVRNIEvents 20001}
|
|
|
|
vmwEntityPropertiesChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Property Change Event"
|
|
::= { vmwVRNIEvents 20002}
|
|
|
|
vmwFirewallNotInstalledOnHostEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Firewall Not Installed On Host Event"
|
|
::= { vmwVRNIEvents 20003}
|
|
|
|
vmwHostWithStaleFirewallRulesEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host With Stale Firewall Rules Event"
|
|
::= { vmwVRNIEvents 20004}
|
|
|
|
vmwIpAddressChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Ip Address Change"
|
|
::= { vmwVRNIEvents 20005}
|
|
|
|
vmwL2GatewayAnomalyEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"L2 Gateway Anomaly Event"
|
|
::= { vmwVRNIEvents 20006}
|
|
|
|
vmwL2NetworkAddressAnomalyEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"L2 Network Address Anomaly Event"
|
|
::= { vmwVRNIEvents 20007}
|
|
|
|
vmwL2NetworkDiameterExceededEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"L2 Network Diameter Exceeded Event"
|
|
::= { vmwVRNIEvents 20008}
|
|
|
|
vmwL2NetworkUplinkMissingEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"L2 Network Uplink Missing Event"
|
|
::= { vmwVRNIEvents 20009}
|
|
|
|
vmwL2NetworkWithNoVMsEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"L2 Network With No VMs Event"
|
|
::= { vmwVRNIEvents 20010}
|
|
|
|
vmwLayer2NetworkDiameterChangedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Layer2 Network Diameter Changed Event"
|
|
::= { vmwVRNIEvents 20011}
|
|
|
|
vmwMTUMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"MTU Mismatch Event"
|
|
::= { vmwVRNIEvents 20012}
|
|
|
|
vmwNetworkIsolationEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Network Isolation Event"
|
|
::= { vmwVRNIEvents 20013}
|
|
|
|
vmwNoPathEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"No Path Event"
|
|
::= { vmwVRNIEvents 20014}
|
|
|
|
vmwSpoofguardDisabledEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Spoofguard Disabled Event"
|
|
::= { vmwVRNIEvents 20015}
|
|
|
|
vmwVMotionEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VMotion Event"
|
|
::= { vmwVRNIEvents 20018}
|
|
|
|
vmwVMWithDisconnectedVnicsEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VM With Disconnected Vnics Event"
|
|
::= { vmwVRNIEvents 20019}
|
|
|
|
vmwVMWithMulipleVnicsOnDifferentVxlansEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VM With Multiple Vnics On Different Vxlans Event"
|
|
::= { vmwVRNIEvents 20020}
|
|
|
|
vmwVMWithMulipleVnicsOnSameL2Event NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VM With Multiple Vnics On Same L2 Event"
|
|
::= { vmwVRNIEvents 20021}
|
|
|
|
vmwVMWithNoIpAddressEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VM With No Ip Address Event"
|
|
::= { vmwVRNIEvents 20022}
|
|
|
|
vmwVTEPMissingEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VTEP Missing Event"
|
|
::= { vmwVRNIEvents 20023}
|
|
|
|
vmwL2Event NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"L2 Event"
|
|
::= { vmwVRNIEvents 20024}
|
|
|
|
vmwMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Membership Change"
|
|
::= { vmwVRNIEvents 20025}
|
|
|
|
vmwSecurityGroupMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Security Group Membership Change"
|
|
::= { vmwVRNIEvents 20026}
|
|
|
|
vmwFirewallRuleMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Firewall Rule Membership Change"
|
|
::= { vmwVRNIEvents 20027}
|
|
|
|
vmwVlanMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Vlan Membership Change"
|
|
::= { vmwVRNIEvents 20028}
|
|
|
|
vmwVxlanMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Vxlan Membership Change"
|
|
::= { vmwVRNIEvents 20029}
|
|
|
|
vmwDeleteChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Delete Event"
|
|
::= { vmwVRNIEvents 20030}
|
|
|
|
vmwVtepFailedPingEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VTEP Ping Failure Event"
|
|
::= { vmwVRNIEvents 20031}
|
|
|
|
vmwEmptySearchStreamChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Search with no results"
|
|
::= { vmwVRNIEvents 20034}
|
|
|
|
vmwSearchStreamMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Search results changed"
|
|
::= { vmwVRNIEvents 20035}
|
|
|
|
vmwEmptySearchStreamProblemEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Search with no results (Problem)"
|
|
::= { vmwVRNIEvents 20036}
|
|
|
|
vmwSearchStreamMembershipProblemEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Search results changed (Problem)"
|
|
::= { vmwVRNIEvents 20037}
|
|
|
|
vmwOspfConfigurationMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"OSPF Mismatch Event"
|
|
::= { vmwVRNIEvents 20038}
|
|
|
|
vmwServiceVMNotHealthyEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Service VM Not Healthy Event"
|
|
::= { vmwVRNIEvents 20039}
|
|
|
|
vmwServiceVMNotPoweredOnEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Service VM Not Powered On Event"
|
|
::= { vmwVRNIEvents 20040}
|
|
|
|
vmwServiceVMHighCPUUsageEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Service VM High CPU Usage Event"
|
|
::= { vmwVRNIEvents 20041}
|
|
|
|
vmwServiceVMHighMemoryUsageEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Service VM High Memory Usage Event"
|
|
::= { vmwVRNIEvents 20042}
|
|
|
|
vmwServiceVMHighDiskUsageEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Service VM High Disk Usage Event"
|
|
::= { vmwVRNIEvents 20043}
|
|
|
|
vmwIPSetPropertiesChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"IPSet Change"
|
|
::= { vmwVRNIEvents 20050}
|
|
|
|
vmwFirewallRulePropertiesChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Firewall Rule Change"
|
|
::= { vmwVRNIEvents 20051}
|
|
|
|
vmwSecurityGroupPropertiesChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Security Group Change"
|
|
::= { vmwVRNIEvents 20052}
|
|
|
|
vmwIPSetMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"IPSet Membership Change"
|
|
::= { vmwVRNIEvents 20053}
|
|
|
|
vmwFirewallRuleMaskEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Firewall Rule Masked Event"
|
|
::= { vmwVRNIEvents 20054}
|
|
|
|
vmwSecurityMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Security Membership Change"
|
|
::= { vmwVRNIEvents 20056}
|
|
|
|
vmwSecurityTagPropertiesChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Security Tag Change"
|
|
::= { vmwVRNIEvents 20057}
|
|
|
|
vmwSecurityTagMembershipChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Security Tag Membership Change"
|
|
::= { vmwVRNIEvents 20058}
|
|
|
|
vmwHostDatastoreChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host datastores changed"
|
|
::= { vmwVRNIEvents 20059}
|
|
|
|
vmwVMDatastoreChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VM datastores changed"
|
|
::= { vmwVRNIEvents 20060}
|
|
|
|
vmwVMSnapshotChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VM snapshot changed"
|
|
::= { vmwVRNIEvents 20061}
|
|
|
|
vmwVMVirtualDiskChangeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Virtual disk migrated"
|
|
::= { vmwVRNIEvents 20062}
|
|
|
|
vmwIPSetDefinitionMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"IPSET Definition Mismatch Event"
|
|
::= { vmwVRNIEvents 20063}
|
|
|
|
vmwSegmentMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Segment Mismatch Event"
|
|
::= { vmwVRNIEvents 20064}
|
|
|
|
vmwVtepEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Vtep Event"
|
|
::= { vmwVRNIEvents 20065}
|
|
|
|
vmwVtepConfigurationFaultEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Vtep Configuration Fault Event"
|
|
::= { vmwVRNIEvents 20066}
|
|
|
|
vmwVtepSubnetMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Vtep Subnet Mismatch Event"
|
|
::= { vmwVRNIEvents 20068}
|
|
|
|
vmwVtepCountMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Vtep Count Mismatch Event"
|
|
::= { vmwVRNIEvents 20069}
|
|
|
|
vmwDLRNetworksNotReachableEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"DLR Routing event"
|
|
::= { vmwVRNIEvents 20067}
|
|
|
|
vmwEdgeNetworksNotReachableEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Edge Routing event"
|
|
::= { vmwVRNIEvents 20070}
|
|
|
|
vmwThresholdExceededEventCpuReady NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded Cpu Ready"
|
|
::= { vmwVRNIEvents 30001}
|
|
|
|
vmwThresholdExceededEventCpuCoStop NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded Cpu Co Stop"
|
|
::= { vmwVRNIEvents 30002}
|
|
|
|
vmwThresholdExceededEventDiskCommandAbortRule NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded Disk Command Abort Rule"
|
|
::= { vmwVRNIEvents 30003}
|
|
|
|
vmwThresholdExceededEventIODeviceLatencyRule NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded IO Device Latency Rule"
|
|
::= { vmwVRNIEvents 30004}
|
|
|
|
vmwThresholdExceededEventIOKernelLatencyRule NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded IO Kernel Latency Rule"
|
|
::= { vmwVRNIEvents 30005}
|
|
|
|
vmwThresholdExceededEventMemorySwapInRule NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded Memory Swap In Rule"
|
|
::= { vmwVRNIEvents 30006}
|
|
|
|
vmwThresholdExceededEventMemorySwapOutRule NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded Memory Swap Out Rule"
|
|
::= { vmwVRNIEvents 30007}
|
|
|
|
vmwThresholdExceededEventNetworkRxDropRule NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded Memory Rx Drop Rule"
|
|
::= { vmwVRNIEvents 30008}
|
|
|
|
vmwThresholdExceededEventNetworkTxDropRule NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Threshold Exceeded Memory Tx Drop Rule"
|
|
::= { vmwVRNIEvents 30009}
|
|
|
|
vmwPacketDropEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Packet Drop Event"
|
|
::= { vmwVRNIEvents 30100}
|
|
|
|
vmwSwitchPortPacketDropEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Switch Port Packet Drop"
|
|
::= { vmwVRNIEvents 30101}
|
|
|
|
vmwRouterInterfacePacketDropEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Router Interface Packet Drop"
|
|
::= { vmwVRNIEvents 30102}
|
|
|
|
vmwVnicPacketDropEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Vnic Packet Drop"
|
|
::= { vmwVRNIEvents 30103}
|
|
|
|
vmwVTEPUnderlayPacketDropEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"VTEP Underlay Packet Drop"
|
|
::= { vmwVRNIEvents 30104}
|
|
|
|
vmwPnicUnderlyingSwitchPortPacketDropEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"PNIC Underlying Switch Port Packet Drop"
|
|
::= { vmwVRNIEvents 30105}
|
|
|
|
vmwDevicePacketDropEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Device Packet Drop"
|
|
::= { vmwVRNIEvents 30106}
|
|
|
|
vmwThresholdExceededEventDatastoreFreeSpaceWarning NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ThresholdExceededEventDatastoreFreeSpaceWarning"
|
|
::= { vmwVRNIEvents 30203}
|
|
|
|
vmwThresholdExceededEventDatastoreFreeSpaceCritical NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ThresholdExceededEventDatastoreFreeSpaceCritical"
|
|
::= { vmwVRNIEvents 30204}
|
|
|
|
vmwThresholdExceededEventDatastoreReadLatency NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ThresholdExceededEventDatastoreReadLatency"
|
|
::= { vmwVRNIEvents 30205}
|
|
|
|
vmwThresholdExceededEventDatastoreWriteLatency NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"ThresholdExceededEventDatastoreWriteLatency"
|
|
::= { vmwVRNIEvents 30206}
|
|
|
|
vmwDistributedFirewallApplyHostEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Distributed Firewall Apply Host Event"
|
|
::= { vmwVRNIEvents 35001}
|
|
|
|
vmwDistributedFirewallApplyVMEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Distributed Firewall Apply VM Event"
|
|
::= { vmwVRNIEvents 35002}
|
|
|
|
vmwNsxEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Nsx Event"
|
|
::= { vmwVRNIEvents 35003}
|
|
|
|
vmwFeatureImpactedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Feature Impacted Event"
|
|
::= { vmwVRNIEvents 35004}
|
|
|
|
vmwClusterFeatureVersionMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Cluster Feature Mismatch Event"
|
|
::= { vmwVRNIEvents 36022}
|
|
|
|
vmwHostFeatureVersionMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Feature Mismatch Event"
|
|
::= { vmwVRNIEvents 36023}
|
|
|
|
vmwFeatureVersionMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Feature Version Mismatch Event"
|
|
::= { vmwVRNIEvents 36024}
|
|
|
|
vmwHostFeatureEnabledMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Feature Enabled Mismatch Event"
|
|
::= { vmwVRNIEvents 36025}
|
|
|
|
vmwHostFeatureInstalledMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Feature Installed Mismatch Event"
|
|
::= { vmwVRNIEvents 36026}
|
|
|
|
vmwHostVtepNotFoundEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Vtep Not Found Event"
|
|
::= { vmwVRNIEvents 36027}
|
|
|
|
vmwHostVtepDisconnectedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Vtep Disconnected Event"
|
|
::= { vmwVRNIEvents 36028}
|
|
|
|
vmwHostVtepEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Vtep Event"
|
|
::= { vmwVRNIEvents 36029}
|
|
|
|
vmwClusterHostsVtepMTUMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Vtep Mtu Mismatch Event"
|
|
::= { vmwVRNIEvents 36030}
|
|
|
|
vmwFeatureUnhealthyEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Feature Health Event"
|
|
::= { vmwVRNIEvents 36031}
|
|
|
|
vmwEdgeHANotConfiguredEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Edge High Availability is not enabled Event"
|
|
::= { vmwVRNIEvents 36032}
|
|
|
|
vmwEdgeInterfacesDownEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"One or More NSX Edge Interfaces are down Event"
|
|
::= { vmwVRNIEvents 36033}
|
|
|
|
vmwModuleUnhealthyEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Module Unhealthy Event"
|
|
::= { vmwVRNIEvents 36041}
|
|
|
|
vmwModuleNotLoadedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Module Not Loaded Event"
|
|
::= { vmwVRNIEvents 36042}
|
|
|
|
vmwModuleNetworkConnectionFailureEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Module Network Connection Failure Event"
|
|
::= { vmwVRNIEvents 36043}
|
|
|
|
vmwHostNetworkControlPlaneMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Control Plane Network Mismatch Event"
|
|
::= { vmwVRNIEvents 36044}
|
|
|
|
vmwHostNetworkControlPlaneConnectionFailureEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Control Plane Network Connection Failure Event"
|
|
::= { vmwVRNIEvents 36045}
|
|
|
|
vmwHostNetworkControlPlaneNotSyncedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Control Plane Sync Failure Event"
|
|
::= { vmwVRNIEvents 36046}
|
|
|
|
vmwNSXControllerClusterMajorityEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Controller Cluster Majority Event"
|
|
::= { vmwVRNIEvents 36047}
|
|
|
|
vmwNSXControllersVMOnSameHostEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Controllers VM On Same Host Event"
|
|
::= { vmwVRNIEvents 36048}
|
|
|
|
vmwVxLanRangeExhaustEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Vxlan range exhaust Event"
|
|
::= { vmwVRNIEvents 36049}
|
|
|
|
vmwNSXFirewallDefaultAllowAllRulesEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Firewall Allow All Rules Event"
|
|
::= { vmwVRNIEvents 36050}
|
|
|
|
vmwLogicalRouterNoUplinkEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Logical Router does not have an uplink interface configured Event"
|
|
::= { vmwVRNIEvents 36051}
|
|
|
|
vmwEdgeNotHAEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Edge not Highly Available Event"
|
|
::= { vmwVRNIEvents 36052}
|
|
|
|
vmwEdgeNotDeployedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Edge not deployed Event"
|
|
::= { vmwVRNIEvents 36053}
|
|
|
|
vmwEcmpIsEnabledAndStatefulServicesAreUpEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Edge Running with both ECMP and Stateful Edge Services Event"
|
|
::= { vmwVRNIEvents 36054}
|
|
|
|
vmwLogicalRouterDeployedOnEcmpEdgeHostEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Logical Router and ECMP Edge on Same Host Event"
|
|
::= { vmwVRNIEvents 36055}
|
|
|
|
vmwEdgeMissingInterfaceOSPFAreaMappingEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Edge Interface to OSPF Area Mapping Missing Event"
|
|
::= { vmwVRNIEvents 36056}
|
|
|
|
vmwOspfInsecureAuthRouterEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"One or more OSPF areas on the NSX Edge are using insecure authentication Event"
|
|
::= { vmwVRNIEvents 36057}
|
|
|
|
vmwNSXControllersDeployedCountEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Controller count Event"
|
|
::= { vmwVRNIEvents 36058}
|
|
|
|
vmwNSXControllerNotActiveCountEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Controller Not Active Event"
|
|
::= { vmwVRNIEvents 36059}
|
|
|
|
vmwNSXControllerEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Nsx Controller Event"
|
|
::= { vmwVRNIEvents 36060}
|
|
|
|
vmwNSXEcmpEdgeDownEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"One or more NSX Edges in the ECMP Cluster are obsoletely down"
|
|
::= { vmwVRNIEvents 36061}
|
|
|
|
vmwNSXMajorityEcmpEdgesDownEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The majority of NSX Edges in the ECMP Cluster are obsoletely down"
|
|
::= { vmwVRNIEvents 36062}
|
|
|
|
vmwNSXAllEcmpEdgesDownEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"All NSX Edges in the ECMP Cluster are obsoletely down"
|
|
::= { vmwVRNIEvents 36063}
|
|
|
|
vmwNSXEdgeMtuMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The MTU configured on one or more interfaces on the Edge does not match the MTU on the next hop router"
|
|
::= { vmwVRNIEvents 36064}
|
|
|
|
vmwNSXEdgeSplitBrainEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Both VMs of Edge HA are in active state"
|
|
::= { vmwVRNIEvents 36065}
|
|
|
|
vmwNSXComponentEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Service not running event"
|
|
::= { vmwVRNIEvents 35221}
|
|
|
|
vmwNSXBackupEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Backup not configured"
|
|
::= { vmwVRNIEvents 35222}
|
|
|
|
vmwNSXBackupAuditLogExcludedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Audit Log excluded from NSX Backup"
|
|
::= { vmwVRNIEvents 35223}
|
|
|
|
vmwNSXUnsecureBackupEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX Backups not using secure FTP"
|
|
::= { vmwVRNIEvents 35224}
|
|
|
|
vmwNSXBackupSystemEventsExcludedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"System Event excluded from NSX Backup"
|
|
::= { vmwVRNIEvents 35225}
|
|
|
|
vmwNSXBackupNotScheduledEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Scheduled backups are not enabled"
|
|
::= { vmwVRNIEvents 35226}
|
|
|
|
vmwNSXBackupNotRecordedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"No backup of the environment has been recorded"
|
|
::= { vmwVRNIEvents 35227}
|
|
|
|
vmwNSXNtpServerEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NTP Server not configured"
|
|
::= { vmwVRNIEvents 35228}
|
|
|
|
vmwNSXSysLogServerEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Syslog Server not configured"
|
|
::= { vmwVRNIEvents 35229}
|
|
|
|
vmwControllerSysLogServerEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Syslog Server not configured"
|
|
::= { vmwVRNIEvents 35230}
|
|
|
|
vmwNSXIpV6EnabledEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"IPv6 is enabled for NSX Manager"
|
|
::= { vmwVRNIEvents 35231}
|
|
|
|
vmwNSXOspfNeighborDownEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"One or more OSPF Neighbors down"
|
|
::= { vmwVRNIEvents 35232}
|
|
|
|
vmwGenericNSXSystemEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX System Events (Warning)"
|
|
::= { vmwVRNIEvents 70000}
|
|
|
|
vmwOtherCriticalNSXEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"NSX System Events (Critical)"
|
|
::= { vmwVRNIEvents 71000}
|
|
|
|
vmwFilterConfigApplyOnHostFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Filter Config Apply On Host Failed Event"
|
|
::= { vmwVRNIEvents 70001}
|
|
|
|
vmwRulesetLoadOnHostFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Ruleset Load On Host Failed Event"
|
|
::= { vmwVRNIEvents 70002}
|
|
|
|
vmwConfigUpdateOnHostFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Config Update On Host Failed Event"
|
|
::= { vmwVRNIEvents 70003}
|
|
|
|
vmwSpoofguardConfigUpdateOnHostFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Spoofguard Config Update On Host Failed Event"
|
|
::= { vmwVRNIEvents 70004}
|
|
|
|
vmwApplyRuleToVnicFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Apply Rule To Vnic Failed Event"
|
|
::= { vmwVRNIEvents 70005}
|
|
|
|
vmwContainerConfigUpdateOnVnicFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Container Config Update On Vnic Failed Event"
|
|
::= { vmwVRNIEvents 70006}
|
|
|
|
vmwSpoofguardApplyToVnicFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Spoofguard Apply To Vnic Failed Event"
|
|
::= { vmwVRNIEvents 70007}
|
|
|
|
vmwHostMessagingConfigurationFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Messaging Configuration Failed Event"
|
|
::= { vmwVRNIEvents 70008}
|
|
|
|
vmwHostMessagingConnectionReconfigurationFailedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Messaging Connection Reconfiguration Failed Event"
|
|
::= { vmwVRNIEvents 70009}
|
|
|
|
vmwHostMessagingConfigurationFailedNotificationSkippedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Messaging Configuration Failed Notification Skipped Event"
|
|
::= { vmwVRNIEvents 70010}
|
|
|
|
vmwHostMessagingInfrastructureDownEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host Messaging Infrastructure Down Event"
|
|
::= { vmwVRNIEvents 70011}
|
|
|
|
vmwEdgeVMNotRespondingEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Edge VM Responding Event"
|
|
::= { vmwVRNIEvents 70012}
|
|
|
|
vmwEdgeUnhealthyEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Edge Health Event"
|
|
::= { vmwVRNIEvents 70013}
|
|
|
|
vmwEdgeVMCommunicationFailureEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Edge communication failure Event"
|
|
::= { vmwVRNIEvents 70014}
|
|
|
|
vmwNSXEdgeEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Nsx Edge Event"
|
|
::= { vmwVRNIEvents 70015}
|
|
|
|
vmwPanEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Palo Alto Event"
|
|
::= { vmwVRNIEvents 80000}
|
|
|
|
vmwPanNsxNotInRegisteredStateEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Palo Alto Nsx Registration Event"
|
|
::= { vmwVRNIEvents 80001}
|
|
|
|
vmwPanNsxDynamicUpdateDelayedEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Palo Alto Nsx Dynamic Update Event"
|
|
::= { vmwVRNIEvents 80002}
|
|
|
|
vmwPanDeviceInDisconnectedStateEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Palo Alto Device Disconnect Event"
|
|
::= { vmwVRNIEvents 80003}
|
|
|
|
vmwPanNsxServiceApplianceViewMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Palo Alto Service Device Mismatch Event"
|
|
::= { vmwVRNIEvents 80004}
|
|
|
|
vmwPanNsxFabricAgentNotFoundOnHostEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Nsx Fabric Agent Not Found Event"
|
|
::= { vmwVRNIEvents 80005}
|
|
|
|
vmwPanNsxServiceVMNotFoundOnHostEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Palo Alto Service VM Not Found Event"
|
|
::= { vmwVRNIEvents 80006}
|
|
|
|
vmwCheckpointEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Check Point Event"
|
|
::= { vmwVRNIEvents 80100}
|
|
|
|
vmwCheckpointNsxFabricAgentNotFoundOnHostEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Check Point Nsx Fabric Agent Not Found Event"
|
|
::= { vmwVRNIEvents 80102}
|
|
|
|
vmwCheckpointNsxServiceVMNotFoundOnHostEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Check Point Service VM Not Found Event"
|
|
::= { vmwVRNIEvents 80103}
|
|
|
|
vmwCheckpointGatewaySicStatusNotCommunicatingEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Check Point Gateway Sic Status Not Communicating Event"
|
|
::= { vmwVRNIEvents 80104}
|
|
|
|
vmwCheckpointNsxServiceApplianceViewMismatchEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Check Point Service VM Mismatch Event"
|
|
::= { vmwVRNIEvents 80105}
|
|
|
|
vmwCriticalHostNotAccessibleEvent NOTIFICATION-TYPE
|
|
OBJECTS { vmwAffectedObject, vmwEventSeverity, vmwVrniUrl, vmwTimestamp, vmwOperatorDesc, vmwEventName }
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Host with VMs running critical services is not accessible"
|
|
::= { vmwVRNIEvents 40001}
|
|
|
|
-- **********************************************************
|
|
-- Notification parameters
|
|
-- **********************************************************
|
|
|
|
vmwAffectedObject OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Object affected by this event"
|
|
::= { vmwVRNIData 102}
|
|
|
|
|
|
vmwEventSeverity OBJECT-TYPE
|
|
SYNTAX VmwVrniSeverity
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Event Severity
|
|
For Problems, Major - Opens and alarms, Cleared Closes it
|
|
For Notifications - All are Info
|
|
"
|
|
::= { vmwVRNIData 103}
|
|
|
|
vmwVrniUrl OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"URL to vRNI for this exact event"
|
|
::= { vmwVRNIData 104}
|
|
|
|
|
|
vmwTimestamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Time of first detection of event"
|
|
::= { vmwVRNIData 105}
|
|
|
|
vmwOperatorDesc OBJECT-TYPE
|
|
SYNTAX VmwLongSnmpAdminString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Human readable message of the event"
|
|
::= { vmwVRNIData 106}
|
|
|
|
vmwEventName OBJECT-TYPE
|
|
SYNTAX VmwLongSnmpAdminString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"This is the search string an operator as entered into VRNI. For example:
|
|
top 20 vms where cpu utilization > 50%"
|
|
::= { vmwVRNIData 107}
|
|
|
|
|
|
-- conformance information
|
|
vmwNetworkInsightMIBConformance OBJECT IDENTIFIER ::= { vmwNetworkInsightMIB 99 }
|
|
vmwNetworkInsightMIBCompliances OBJECT IDENTIFIER ::=
|
|
{ vmwNetworkInsightMIBConformance 1 }
|
|
vmwNetworkInsightMIBGroups OBJECT IDENTIFIER ::= { vmwNetworkInsightMIBConformance 2 }
|
|
|
|
-- compliance statements
|
|
vmwNetworkInsightMIBBasicCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
VMWARE-VRNI-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup1,
|
|
vmwNetworkInsightNotificationGroup1 }
|
|
::= { vmwNetworkInsightMIBCompliances 3 }
|
|
|
|
vmwNetworkInsightNotificationInfoGroup1 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwAffectedObject,
|
|
vmwEventSeverity,
|
|
vmwVrniUrl,
|
|
vmwTimestamp,
|
|
vmwOperatorDesc
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"These objects provide details in VRNI notifications."
|
|
::= { vmwNetworkInsightMIBGroups 2 }
|
|
|
|
vmwNetworkInsightNotificationGroup1 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwSnmpTrapsAreConfigured,
|
|
vmwSnmpTrapsAreDisabled,
|
|
vmwTestTrap,
|
|
vmwEntityDiscoveryChangeEvent,
|
|
vmwEntityPropertiesChangeEvent,
|
|
vmwFirewallNotInstalledOnHostEvent,
|
|
vmwHostWithStaleFirewallRulesEvent,
|
|
vmwIpAddressChangeEvent,
|
|
vmwL2GatewayAnomalyEvent,
|
|
vmwL2NetworkAddressAnomalyEvent,
|
|
vmwL2NetworkDiameterExceededEvent,
|
|
vmwL2NetworkUplinkMissingEvent,
|
|
vmwL2NetworkWithNoVMsEvent,
|
|
vmwLayer2NetworkDiameterChangedEvent,
|
|
vmwMTUMismatchEvent,
|
|
vmwNetworkIsolationEvent,
|
|
vmwNoPathEvent,
|
|
vmwSpoofguardDisabledEvent,
|
|
vmwVMotionEvent,
|
|
vmwVMWithDisconnectedVnicsEvent,
|
|
vmwVMWithMulipleVnicsOnDifferentVxlansEvent,
|
|
vmwVMWithMulipleVnicsOnSameL2Event,
|
|
vmwVMWithNoIpAddressEvent,
|
|
vmwVTEPMissingEvent,
|
|
vmwL2Event,
|
|
vmwMembershipChangeEvent,
|
|
vmwSecurityGroupMembershipChangeEvent,
|
|
vmwFirewallRuleMembershipChangeEvent,
|
|
vmwVlanMembershipChangeEvent,
|
|
vmwVxlanMembershipChangeEvent,
|
|
vmwDeleteChangeEvent,
|
|
vmwVtepFailedPingEvent,
|
|
vmwEmptySearchStreamChangeEvent,
|
|
vmwSearchStreamMembershipChangeEvent,
|
|
vmwEmptySearchStreamProblemEvent,
|
|
vmwSearchStreamMembershipProblemEvent,
|
|
vmwOspfConfigurationMismatchEvent,
|
|
vmwServiceVMNotHealthyEvent,
|
|
vmwServiceVMNotPoweredOnEvent,
|
|
vmwServiceVMHighCPUUsageEvent,
|
|
vmwServiceVMHighMemoryUsageEvent,
|
|
vmwServiceVMHighDiskUsageEvent,
|
|
vmwIPSetPropertiesChangeEvent,
|
|
vmwFirewallRulePropertiesChangeEvent,
|
|
vmwSecurityGroupPropertiesChangeEvent,
|
|
vmwIPSetMembershipChangeEvent,
|
|
vmwFirewallRuleMaskEvent,
|
|
vmwSecurityMembershipChangeEvent,
|
|
vmwSecurityTagPropertiesChangeEvent,
|
|
vmwSecurityTagMembershipChangeEvent,
|
|
vmwHostDatastoreChangeEvent,
|
|
vmwVMDatastoreChangeEvent,
|
|
vmwVMSnapshotChangeEvent,
|
|
vmwVMVirtualDiskChangeEvent,
|
|
vmwIPSetDefinitionMismatchEvent,
|
|
vmwSegmentMismatchEvent,
|
|
vmwVtepEvent,
|
|
vmwVtepConfigurationFaultEvent,
|
|
vmwVtepSubnetMismatchEvent,
|
|
vmwVtepCountMismatchEvent,
|
|
vmwDLRNetworksNotReachableEvent,
|
|
vmwEdgeNetworksNotReachableEvent,
|
|
vmwThresholdExceededEventCpuReady,
|
|
vmwThresholdExceededEventCpuCoStop,
|
|
vmwThresholdExceededEventDiskCommandAbortRule,
|
|
vmwThresholdExceededEventIODeviceLatencyRule,
|
|
vmwThresholdExceededEventIOKernelLatencyRule,
|
|
vmwThresholdExceededEventMemorySwapInRule,
|
|
vmwThresholdExceededEventMemorySwapOutRule,
|
|
vmwThresholdExceededEventNetworkRxDropRule,
|
|
vmwThresholdExceededEventNetworkTxDropRule,
|
|
vmwPacketDropEvent,
|
|
vmwSwitchPortPacketDropEvent,
|
|
vmwRouterInterfacePacketDropEvent,
|
|
vmwVnicPacketDropEvent,
|
|
vmwVTEPUnderlayPacketDropEvent,
|
|
vmwPnicUnderlyingSwitchPortPacketDropEvent,
|
|
vmwDevicePacketDropEvent,
|
|
vmwThresholdExceededEventDatastoreFreeSpaceWarning,
|
|
vmwThresholdExceededEventDatastoreFreeSpaceCritical,
|
|
vmwThresholdExceededEventDatastoreReadLatency,
|
|
vmwThresholdExceededEventDatastoreWriteLatency,
|
|
vmwDistributedFirewallApplyHostEvent,
|
|
vmwDistributedFirewallApplyVMEvent,
|
|
vmwNsxEvent,
|
|
vmwFeatureImpactedEvent,
|
|
vmwClusterFeatureVersionMismatchEvent,
|
|
vmwHostFeatureVersionMismatchEvent,
|
|
vmwFeatureVersionMismatchEvent,
|
|
vmwHostFeatureEnabledMismatchEvent,
|
|
vmwHostFeatureInstalledMismatchEvent,
|
|
vmwHostVtepNotFoundEvent,
|
|
vmwHostVtepDisconnectedEvent,
|
|
vmwHostVtepEvent,
|
|
vmwClusterHostsVtepMTUMismatchEvent,
|
|
vmwFeatureUnhealthyEvent,
|
|
vmwEdgeHANotConfiguredEvent,
|
|
vmwEdgeInterfacesDownEvent,
|
|
vmwModuleUnhealthyEvent,
|
|
vmwModuleNotLoadedEvent,
|
|
vmwModuleNetworkConnectionFailureEvent,
|
|
vmwHostNetworkControlPlaneMismatchEvent,
|
|
vmwHostNetworkControlPlaneConnectionFailureEvent,
|
|
vmwHostNetworkControlPlaneNotSyncedEvent,
|
|
vmwNSXControllerClusterMajorityEvent,
|
|
vmwNSXControllersVMOnSameHostEvent,
|
|
vmwVxLanRangeExhaustEvent,
|
|
vmwNSXFirewallDefaultAllowAllRulesEvent,
|
|
vmwEdgeNotHAEvent,
|
|
vmwEdgeNotDeployedEvent,
|
|
vmwEcmpIsEnabledAndStatefulServicesAreUpEvent,
|
|
vmwLogicalRouterDeployedOnEcmpEdgeHostEvent,
|
|
vmwEdgeMissingInterfaceOSPFAreaMappingEvent,
|
|
vmwOspfInsecureAuthRouterEvent,
|
|
vmwNSXControllersDeployedCountEvent,
|
|
vmwNSXControllerNotActiveCountEvent,
|
|
vmwNSXControllerEvent,
|
|
vmwNSXBackupEvent,
|
|
vmwNSXUnsecureBackupEvent,
|
|
vmwNSXBackupSystemEventsExcludedEvent,
|
|
vmwNSXBackupNotScheduledEvent,
|
|
vmwNSXBackupNotRecordedEvent,
|
|
vmwNSXNtpServerEvent,
|
|
vmwNSXSysLogServerEvent,
|
|
vmwControllerSysLogServerEvent,
|
|
vmwGenericNSXSystemEvent,
|
|
vmwOtherCriticalNSXEvent,
|
|
vmwFilterConfigApplyOnHostFailedEvent,
|
|
vmwRulesetLoadOnHostFailedEvent,
|
|
vmwConfigUpdateOnHostFailedEvent,
|
|
vmwSpoofguardConfigUpdateOnHostFailedEvent,
|
|
vmwApplyRuleToVnicFailedEvent,
|
|
vmwContainerConfigUpdateOnVnicFailedEvent,
|
|
vmwSpoofguardApplyToVnicFailedEvent,
|
|
vmwHostMessagingConfigurationFailedEvent,
|
|
vmwHostMessagingConnectionReconfigurationFailedEvent,
|
|
vmwHostMessagingConfigurationFailedNotificationSkippedEvent,
|
|
vmwHostMessagingInfrastructureDownEvent,
|
|
vmwEdgeVMNotRespondingEvent,
|
|
vmwEdgeUnhealthyEvent,
|
|
vmwEdgeVMCommunicationFailureEvent,
|
|
vmwNSXEdgeEvent,
|
|
vmwPanEvent,
|
|
vmwPanNsxNotInRegisteredStateEvent,
|
|
vmwPanNsxDynamicUpdateDelayedEvent,
|
|
vmwPanDeviceInDisconnectedStateEvent,
|
|
vmwPanNsxServiceApplianceViewMismatchEvent,
|
|
vmwPanNsxFabricAgentNotFoundOnHostEvent,
|
|
vmwPanNsxServiceVMNotFoundOnHostEvent
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Set of notifications (traps, informs) supported in this first version."
|
|
::= { vmwNetworkInsightMIBGroups 3 }
|
|
|
|
vmwNetworkInsightMIBBasicCompliance2 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
VMWARE-VRNI-MIB second version."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup2,
|
|
vmwNetworkInsightNotificationGroup1,
|
|
vmwNetworkInsightNotificationGroup2
|
|
}
|
|
::= { vmwNetworkInsightMIBCompliances 30 }
|
|
|
|
vmwNetworkInsightNotificationInfoGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwAffectedObject,
|
|
vmwEventSeverity,
|
|
vmwVrniUrl,
|
|
vmwTimestamp,
|
|
vmwOperatorDesc,
|
|
vmwEventName
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"These events provide details in NSX Manager notifications."
|
|
::= { vmwNetworkInsightMIBGroups 20 }
|
|
|
|
vmwNetworkInsightNotificationGroup2 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwLogicalRouterNoUplinkEvent,
|
|
vmwNSXComponentEvent,
|
|
vmwNSXBackupEvent,
|
|
vmwNSXBackupAuditLogExcludedEvent,
|
|
vmwNSXUnsecureBackupEvent,
|
|
vmwNSXBackupSystemEventsExcludedEvent,
|
|
vmwNSXBackupNotScheduledEvent,
|
|
vmwNSXBackupNotRecordedEvent,
|
|
vmwNSXNtpServerEvent,
|
|
vmwNSXSysLogServerEvent,
|
|
vmwControllerSysLogServerEvent
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Set of added notifications (traps, informs) since last revision."
|
|
::= { vmwNetworkInsightMIBGroups 30 }
|
|
|
|
vmwNetworkInsightMIBBasicCompliance3 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
VMWARE-VRNI-MIB second version."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup2,
|
|
vmwNetworkInsightNotificationGroup1,
|
|
vmwNetworkInsightNotificationGroup2,
|
|
vmwNetworkInsightNotificationGroup3
|
|
}
|
|
::= { vmwNetworkInsightMIBCompliances 35 }
|
|
|
|
vmwNetworkInsightNotificationGroup3 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwMTUMismatchEvent,
|
|
vmwVMWithMulipleVnicsOnSameL2Event,
|
|
vmwMembershipChangeEvent,
|
|
vmwSecurityGroupMembershipChangeEvent,
|
|
vmwFirewallRuleMembershipChangeEvent,
|
|
vmwVlanMembershipChangeEvent,
|
|
vmwVxlanMembershipChangeEvent,
|
|
vmwSearchStreamMembershipChangeEvent,
|
|
vmwIPSetMembershipChangeEvent,
|
|
vmwSecurityMembershipChangeEvent,
|
|
vmwVtepEvent,
|
|
vmwPacketDropEvent,
|
|
vmwSwitchPortPacketDropEvent,
|
|
vmwRouterInterfacePacketDropEvent,
|
|
vmwVnicPacketDropEvent,
|
|
vmwVTEPUnderlayPacketDropEvent,
|
|
vmwPnicUnderlyingSwitchPortPacketDropEvent,
|
|
vmwHostFeatureVersionMismatchEvent,
|
|
vmwSpoofguardConfigUpdateOnHostFailedEvent,
|
|
vmwNSXEcmpEdgeDownEvent,
|
|
vmwNSXMajorityEcmpEdgesDownEvent,
|
|
vmwNSXAllEcmpEdgesDownEvent
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Set of added notifications (traps, informs) since last revision."
|
|
::= { vmwNetworkInsightMIBGroups 40 }
|
|
|
|
vmwNetworkInsightMIBBasicCompliance4 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement
|
|
VMWARE-VRNI-MIB second version."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { vmwNetworkInsightNotificationInfoGroup2,
|
|
vmwNetworkInsightNotificationGroup1,
|
|
vmwNetworkInsightNotificationGroup2,
|
|
vmwNetworkInsightNotificationGroup3,
|
|
vmwNetworkInsightNotificationGroup4
|
|
}
|
|
::= { vmwNetworkInsightMIBCompliances 45 }
|
|
|
|
vmwNetworkInsightNotificationGroup4 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNSXEdgeSplitBrainEvent,
|
|
vmwNSXIpV6EnabledEvent,
|
|
vmwNSXOspfNeighborDownEvent,
|
|
vmwCheckpointEvent,
|
|
vmwNSXEdgeMtuMismatchEvent,
|
|
vmwCheckpointNsxFabricAgentNotFoundOnHostEvent,
|
|
vmwCheckpointNsxServiceVMNotFoundOnHostEvent,
|
|
vmwCheckpointGatewaySicStatusNotCommunicatingEvent,
|
|
vmwCheckpointNsxServiceApplianceViewMismatchEvent,
|
|
vmwCriticalHostNotAccessibleEvent,
|
|
vmwVlanMembershipChangeEvent,
|
|
vmwClusterFeatureVersionMismatchEvent,
|
|
vmwHostFeatureVersionMismatchEvent,
|
|
vmwConfigUpdateOnHostFailedEvent
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"Set of added notifications (traps, informs) since last revision."
|
|
::= { vmwNetworkInsightMIBGroups 50 }
|
|
|
|
END
|