-- Copyright 2019-2023 VMware, Inc. All rights reserved.
|
|
-- **********************************************************
|
|
|
|
VMWARE-NSX-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-IDENTITY, OBJECT-TYPE, NOTIFICATION-TYPE
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE, OBJECT-GROUP, NOTIFICATION-GROUP
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION, DateAndTime
|
|
FROM SNMPv2-TC
|
|
vmwNSXsys
|
|
FROM VMWARE-ROOT-MIB;
|
|
|
|
vmwNSXsysMIB MODULE-IDENTITY
|
|
LAST-UPDATED "202304020000Z"
|
|
ORGANIZATION "VMware, Inc"
|
|
CONTACT-INFO
|
|
"VMware, Inc
|
|
3401 Hillview Ave
|
|
Palo Alto, CA 94304
|
|
Tel: 1-877-486-9273 or 650-427-5000
|
|
Fax: 650-427-5001
|
|
Web: http://kb.vmware.com/kb/1013445
|
|
"
|
|
|
|
DESCRIPTION
|
|
"In much the same way that server virtualization programmatically
|
|
creates, snapshots, deletes, and restores software-based virtual
|
|
machines (VMs), NSX Data Center network virtualization
|
|
programmatically creates, deletes, and restores software-based
|
|
virtual networks.
|
|
|
|
With network virtualization, the functional equivalent of a network
|
|
hypervisor reproduces the complete set of Layer 2 through Layer 7
|
|
networking services (for example, switching, routing, access control,
|
|
firewalling, QoS) in software. As a result, these services can be
|
|
programmatically assembled in any arbitrary combination, to produce
|
|
unique, isolated virtual networks in a matter of seconds.
|
|
|
|
For more information about NSX Data Center, please visit:
|
|
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/
|
|
"
|
|
|
|
REVISION "202304020000Z"
|
|
DESCRIPTION
|
|
"This revision adds 48 new notifications for NSX Data Center 4.1.0"
|
|
|
|
REVISION "202206210000Z"
|
|
DESCRIPTION
|
|
"This revision adds 106 new notifications for NSX Data Center 4.0.0"
|
|
|
|
REVISION "202206160000Z"
|
|
DESCRIPTION
|
|
"This revision adds 6 new notifications for NSX Data Center 3.2.1"
|
|
|
|
REVISION "202202140000Z"
|
|
DESCRIPTION
|
|
"This revision adds 174 new notifications for NSX Data Center 3.2.0"
|
|
|
|
REVISION "202108060000Z"
|
|
DESCRIPTION
|
|
"This revision adds 18 new notifications for NSX Data Center 3.1.3"
|
|
|
|
REVISION "202104220000Z"
|
|
DESCRIPTION
|
|
"This revision adds 12 new notifications for NSX Data Center 3.1.2"
|
|
|
|
REVISION "202103250000Z"
|
|
DESCRIPTION
|
|
"This revision adds 2 new notifications for NSX Data Center 3.0.3"
|
|
|
|
REVISION "202101300000Z"
|
|
DESCRIPTION
|
|
"This revision adds 2 new notifications for NSX Data Center 3.1.1"
|
|
|
|
REVISION "202010300000Z"
|
|
DESCRIPTION
|
|
"This revision adds 56 new notifications for NSX Data Center 3.1.0"
|
|
|
|
REVISION "202009220000Z"
|
|
DESCRIPTION
|
|
"This revision adds 10 new notifications for NSX Data Center 3.0.2"
|
|
|
|
REVISION "202006290000Z"
|
|
DESCRIPTION
|
|
"This revision adds 12 new notifications for NSX Data Center 3.0.1"
|
|
|
|
REVISION "202003240000Z"
|
|
DESCRIPTION
|
|
"Initial revision of NSX Data Center SNMP event notifications."
|
|
|
|
::= { vmwNSXsys 1 }
|
|
|
|
-- **********************************************************
|
|
-- Top-level MIB groups
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDataCenterNotifications OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All event notifications from NSX Data Center fall under this oid."
|
|
::= { vmwNSXsysMIB 0 }
|
|
|
|
vmwNsxTDataCenterData OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All variables that are sent in NSX Data Center event notifications
|
|
fall under this oid."
|
|
::= { vmwNSXsysMIB 1 }
|
|
|
|
-- **********************************************************
|
|
-- Type definitions
|
|
-- **********************************************************
|
|
|
|
VmwNsxTDataCenterFeatureIdType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX Data Center feature ID associated with the event.
|
|
For example, this value identifies the feature is managerHealth,
|
|
edgeHealth, loadBalancer, etc."
|
|
SYNTAX INTEGER {
|
|
managerHealth(1),
|
|
edgeHealth(2),
|
|
certificates(3),
|
|
passwordManagement(4),
|
|
licenses(5),
|
|
intelligenceHealth(6),
|
|
infrastructureCommunication(7),
|
|
intelligenceCommunication(9),
|
|
cniHealth(10),
|
|
ncpHealth(11),
|
|
nodeAgentsHealth(12),
|
|
endpointProtection(13),
|
|
serviceInsertion(14),
|
|
vpn(15),
|
|
alarmManagement(16),
|
|
loadBalancer(17),
|
|
transportNodeHealth(18),
|
|
infrastructureService(19),
|
|
dhcp(20),
|
|
highAvailability(21),
|
|
capacity(22),
|
|
auditLogHealth(24),
|
|
routing(28),
|
|
dns(30),
|
|
distributedFirewall(31),
|
|
federation(32),
|
|
distributedIdsIps(33),
|
|
communication(35),
|
|
identityFirewall(36),
|
|
ipam(38),
|
|
gatewayFirewall(39),
|
|
clustering(40),
|
|
nsxApplicationPlatformCommunication(41),
|
|
mtuCheck(42),
|
|
nsxApplicationPlatformHealth(43),
|
|
edge(45),
|
|
nat(46),
|
|
physicalServer(47),
|
|
malwarePreventionHealth(48),
|
|
edgeCluster(49),
|
|
vmcApp(50),
|
|
tepHealth(51),
|
|
policyConstraint(53),
|
|
groups(54),
|
|
securityCompliance(56),
|
|
nsxaasHealth(58)
|
|
}
|
|
|
|
VmwNsxTDataCenterEventTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the NSX Data Center event. The complete set of events
|
|
are reported by the NSX API GET /api/v1/events."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSeverityType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the NSX Data Center event. Currently only the
|
|
critical(2), error(3), warning(4) and informational(6) levels
|
|
are used, but the other levels may be used in future releases."
|
|
SYNTAX INTEGER {
|
|
emergency(0),
|
|
alert(1),
|
|
critical(2),
|
|
error(3),
|
|
warning(4),
|
|
notice(5),
|
|
informational(6),
|
|
debug(7)
|
|
}
|
|
|
|
VmwNsxTDataCenterNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID from where a NSX Data Center event was emitted. A
|
|
node ID can be for a cluster node as reported by the NSX API
|
|
GET /api/v1/cluster. Or a node ID can be for a transport node
|
|
as reported by the NSX API GET /api/v1/transport-nodes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNodeTypeType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of node from where a NSX Data Center event was emitted."
|
|
SYNTAX INTEGER {
|
|
manager(0),
|
|
edge(1),
|
|
esx(2),
|
|
kvm(3),
|
|
publiccloudgateway(4),
|
|
intelligence(5),
|
|
autonomousedge(6),
|
|
globalmanager(7)
|
|
}
|
|
|
|
VmwNsxTDataCenterEntityIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of a NSX Data Center entity an event pertains to. The event
|
|
description field provides additional details of the entity. For
|
|
example the ID can be for a specific Load Balancer rule as reported by
|
|
the NSX API GET /api/v1/loadbalancer/rules or a specific certificate
|
|
as reported by the NSX API GET /api/v1/trust-management/certificates."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSystemResourceUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU, memory, or disk usage percentage of an NSX appliance. The
|
|
value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDiskPartitionNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a disk partition in an NSX appliance. For example, the
|
|
name for the /tmp partition is '/tmp'."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLicenseEditionTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The edition type of an NSX license. For example, the type for an NSX
|
|
evaluation license is 'NSX Data Center Evaluation'."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterApplianceAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX appliance's IP address. The value is an IPv4 address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCurrentGatewayStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCurrentServiceStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current service state. The value could be start/stop/restart/crashed."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDatapathResourceUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU, memory, or disk usage percentage of the datapath on a NSX appliance.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDHCPPoolUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of a DHCP pool. The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeServiceNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running on the Edge node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFailureReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detailed reason of any module failure like BGP down, IKE down, etc."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPreviousGatewayStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The previous gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPreviousServiceStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The previous service state. The value could be start/stop/restart/crashed."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSystemUsageThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured threshold value for the CPU, memory, or disk usage
|
|
percentage of an NSX appliance. The value is an integer between 0 and
|
|
100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterUsernameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a user in an NSX appliance."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDHCPServerIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UUID of a DHCP server."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterServiceNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running in an NSX appliance."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIntelligenceNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID of an NSX Intelligence node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterHostnameOrIPAddressWithPortType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hostname or ip address with port of logging server."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEventIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event identifier."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterActiveGlobalManagerType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The identifier for the active Global Manager node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterActiveGlobalManagersType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A comma delimited list of identifiers for the active Global Manager nodes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSessionDownReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Down reason of the IPsec VPN session."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterManagerNodeNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The display name of a NSX Manager node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTransportNodeAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP address of a NSX Transport node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTransportNodeNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The display name of a NSX Transport node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCentralControlPlaneIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UUID of a NSX centrol control plane."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTunnelDownReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Down reason of the IPsec VPN tunnel."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterHeapTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Heap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMempoolNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of a memory pool."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPasswordExpirationDaysType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of days left before expiration of the password of an NSX
|
|
appliance user. The value is an integer greater than 0."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterBGPNeighborIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of BGP Neighbor. This could be either IPv4 or IPv6 address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLDAPServerType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name or IP address of a LDAP server."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPeerAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of BFD peer."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMaxIDSEventsAllowedType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The maximum number of IDS events that are allowed in the system, anything beyond this
|
|
would be purged at regular intervals."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterStaticAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Static IP address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDuplicateIPAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Duplicate IP address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCapacityDisplayNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Display name of type on capacity dashboard."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCapacityUsageCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current usage count of capacity usage type."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeNICNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the NIC whose link is down or which faced tx/rx ring buffer overflow."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRxRingBufferOverflowPercentageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC's receive descriptor ring buffer on a NSX Edge or Gateway node has no space left
|
|
to accomodate new incoming packets and there is a significant drop due to it.
|
|
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTxRingBufferOverflowPercentageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC's transmit descriptor ring buffer on a NSX Edge or Gateway node has no space left
|
|
to accomodate new outgoing packets and there is a significant drop due to it.
|
|
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSrIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service Router UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIDSEventsCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Count of the IDS events in the system currently."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRemoteSiteNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of a remote site in federation. For more information on remote
|
|
sites and an overview of the federation feature, refer to:
|
|
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7-8072-50221CF2122A.html"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterBGPSourceIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Source IP address of BGP session. This could be either an IPv4 address
|
|
in dotted-decimal format or an IPv6 address in IPv6 address format."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRemoteSiteIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The identifier for a remote site."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSiteIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The identifier for a local site."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSiteNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of a local site in federation. For more information on local
|
|
sites and an overview of the federation feature, refer to:
|
|
https://docs.vmware.com/en/VMware-NSX-T-Data-Center/3.0/administration/GUID-D5B6DC79-6733-44A7-8072-50221CF2122A.html"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLrIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical Router UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRxMissesType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets missed while receiving due to rx ring buffer being full."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRxProcessedType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of successful incoming packets while polling for rx buffer full event."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTxMissesType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of packets missed while transmitting due to tx ring buffer being full."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTxProcessedType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of successful outgoing packets while polling for tx buffer full event."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLrportIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical Router Port UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterServiceIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IP configured for the service running in an NSX appliance in dotted-decimal format."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRemoteManagerNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote Manager node UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDirectoryDomainType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a directory domain."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTimeoutInMinutesType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Timeout value in minutes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMaxCapacityThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum threshold defined for capacity usage type."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMinCapacityThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minimum threshold defined for capacity usage type."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMaxSupportedCapacityCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum supported count for capacity usage type."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLatencySourceType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The source of reported latency."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLatencyThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold value of reported IO latency."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLatencyValueType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of reported IO latency."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterApplianceFQDNType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX appliance's fully qualified domain name."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRemoteApplianceAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The remote NSX appliance's IP address. The value is an IPv4 address."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterManagerNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Manager node UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDisplayedLicenseKeyType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last 5 characters of the license key of an NSX license."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeThreadNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the Edge node thread."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIntentPathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The policy intent path."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallHalfopenFlowUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall TCP half-open connection usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallICMPFlowUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall ICMP connection usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterServiceDownReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reason service is down."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallUDPFlowUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall UDP connection usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallIPFlowUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall IP connection usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDNSIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DNS forwarder identifier."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDNSUpstreamIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of one DNS forwarder upstream server."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCABundleAgeThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The age threshold in days for the CA bundle."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterAPICollectionPathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The API path of the collection containing entity_id."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeNodeSettingMismatchReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Policy/MP intent of Edge transport node settings
|
|
that differs from corresponding Edge transport node settings on Edge NSX CLI."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Policy/MP intent of Edge transport node vSphere
|
|
deployment configuration that differs from corresponding Edge transport node
|
|
configuration on vSphere."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFirewallSNATPortsUsageType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current firewall SNAT ports usage percentage of max supported value.
|
|
The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgevSphereLocationMismatchReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Policy/MP intent of vSphere deployment configuration that differs
|
|
from corresponding Edge transport node configuration on vSphere when vMotion happens
|
|
for Edge node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Policy/MP intent of Edge transport node settings and vSphere
|
|
deployment configuration that differs from corresponding Edge transport node
|
|
settings on Edge NSX CLI and Edge transport node configuration on vSphere."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSNATIPAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNAT IP address which ran out of port threshold."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappClusterIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cluster ID of the NSX Application Platform cluster."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappMessagingLAGThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured threshold value for the number of pending messages
|
|
in an NSX Application Platform messaging topic."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID of an NSX Application Platform node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappServiceNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service name of an NSX Application Platform service."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFlowIdentifierType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A flow identifier indicating the direction of flow of data which is one of following.
|
|
- GM_2_LM
|
|
- LM_2_GM_NOTIFICATION
|
|
- LM_2_GM_ONBOARD_CONFIG"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSyncIssueReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A reason for data synchronization issue."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterQueueNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the queue used to synchronize data between two sites."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterQueueSizeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The occupancy size of queue used to synchronize data between two sites."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterQueueSizeThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum threshold value of reported queue size."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterGroupTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group type of a GMLE cluster."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterManagerNodeIDSType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A comma delimited list of identifiers for the Manager nodes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterServiceRouterIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of a service-router that is part of a tier0 or tier1 gateway
|
|
spanning one or more edges"
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTransportNodeIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFromGMPathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Policy path of the Global Manager."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterToGMPathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Policy path of the Global Manager."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNICThroughputType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC throughput, as a percentage. The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNICThroughputThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC throughput threshold, as a percentage. The value is an integer between 0 and 100."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeCryptoDrvNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of the edge crypto driver."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNappNodeNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node name of an NSX Application Platform node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNewVMMorefIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Edge VM moref details corresponding to Policy/MP intent
|
|
vSphere deployment configuration."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPolicyEdgeVMNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Edge VM name corresponding to Policy/MP intent
|
|
vSphere deployment configuration."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterVMMorefIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Edge VM moref details corresponding to Policy/MP intent
|
|
vSphere deployment configuration."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDPUIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data processing unit identifier."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeNodeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String representing the Edge node UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPrefixesCountMaxType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum value of prefix count of BGP neighbor."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterPrefixesCountThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Threshold Value of prefix count of BGP neighbor."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRouteLimitMaximumType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String representing maximum limit for routes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterRouteLimitThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String representing threshold limit for routes."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSubsequentAddressFamilyType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String representing subsequent address family (Unicast or Multicast)."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCentervCenterClusterIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Cluster identifier in the Virtual Center."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMpsServiceNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service name of an NSX Malware Prevention service."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMemberIndexIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String representing member index ID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeClusterIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String representing the edge cluster ID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCoreDumpCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of core dump file generated in system."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNodeDisplayOrHostNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Display name or Host name of NSX node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNSXEdgeTNNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The display name of a NSX Edge Transport node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNSXESXTNNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The display name of a NSX Host Transport node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCollectorIPType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"External OPS collector IP address for OPS features."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDvsAliasType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DVS name to indicate given DVS."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterStackAliasType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Stack name specified for given vmknic."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterVerticalNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of OPS vertical on DPU."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeClusterHighestHwVersionType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing highest hardware version of Edge Transport Node in edge cluster."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeTNHwVersionType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing hardware version of Edge Transport Node."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterEdgeClusterNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing Edge cluster display name."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterHaStateType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current high-availability state. The value could be active/standby/down."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterHaState2Type ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current high-availability state. The value could be active/standby/down."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTransportNodeId2Type ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterDvsNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ESXi DVS name."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterVtepFaultReasonType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VTEP fault reason."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterVtepNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ESXi VTEP name."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMetricsTargetAddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of specified target metrics being delivered to."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMetricsTargetAliasType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alias of specified target metrics being delivered to."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMetricsTargetPortType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Listen port of specified target metrics being delivered to."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIPv4AddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of IPv4 address in dual stack."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIPv6AddressType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of IPv6 address in dual stack."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterConstraintLimitType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Value of constraint limit."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterConstraintTypeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Type of constraint resource."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCurrentCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current count of object."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterGroupIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group UUID."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterGroupMaxNumberLimitType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of group elements supported."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterGroupSizeType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of group elements."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterIPCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IP sets inside one group."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLrpCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of logical router port inside one group."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterLspCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of logical switch port inside one group."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterMacCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of MAC sets inside one group."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterSidCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of security IDs inside one group."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterTNCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of Transport Nodes inside one group."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterVifCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of VIFs inside one group."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterVMCountType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of VMs inside one group."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterCoreIdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String to identify the core on which event is triggered."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterFlowCacheThresholdType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String to identify the flow cache threshold."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterNSXaaSServiceNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running in NSXaaS."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterProtocolNameType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"String containing network protocol."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
VmwNsxTDataCenterConstraintTypePathType ::= TEXTUAL-CONVENTION
|
|
DISPLAY-HINT "256a"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Path prefix of constraint resource."
|
|
SYNTAX OCTET STRING (SIZE (0..256))
|
|
|
|
vmwNsxTDataCenterTimestamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The timestamp when the NSX Data Center event occurred."
|
|
::= { vmwNsxTDataCenterData 1 }
|
|
|
|
vmwNsxTDataCenterFeatureName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFeatureIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX Data Center feature ID associated with the event."
|
|
::= { vmwNsxTDataCenterData 2 }
|
|
|
|
vmwNsxTDataCenterEventType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEventTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the NSX Data Center event."
|
|
::= { vmwNsxTDataCenterData 3 }
|
|
|
|
vmwNsxTDataCenterEventSeverity OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSeverityType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The severity of the NSX Data Center event."
|
|
::= { vmwNsxTDataCenterData 4 }
|
|
|
|
vmwNsxTDataCenterNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID from where a NSX Data Center event was emitted."
|
|
::= { vmwNsxTDataCenterData 5 }
|
|
|
|
vmwNsxTDataCenterNodeType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNodeTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of node from where a NSX Data Center event was emitted."
|
|
::= { vmwNsxTDataCenterData 6 }
|
|
|
|
vmwNsxTDataCenterEntityId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEntityIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The ID of a NSX Data Center entity an event pertains to. The event
|
|
description field provides additional details of the entity. For
|
|
example the ID can be for a specific Load Balancer rule as reported by
|
|
the NSX API GET /api/v1/loadbalancer/rules or a specific certificate
|
|
as reported by the NSX API GET /api/v1/trust-management/certificates."
|
|
::= { vmwNsxTDataCenterData 21 }
|
|
|
|
vmwNsxTDataCenterSystemResourceUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSystemResourceUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU, memory, or disk usage percentage of an NSX appliance. The
|
|
value is an integer between 0 and 100."
|
|
::= { vmwNsxTDataCenterData 22 }
|
|
|
|
vmwNsxTDataCenterDiskPartitionName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDiskPartitionNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a disk partition in an NSX appliance. For example, the
|
|
name for the /tmp partition is '/tmp'."
|
|
::= { vmwNsxTDataCenterData 23 }
|
|
|
|
vmwNsxTDataCenterLicenseEditionType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLicenseEditionTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The edition type of an NSX license. For example, the type for an NSX
|
|
evaluation license is 'NSX Data Center Evaluation'."
|
|
::= { vmwNsxTDataCenterData 24 }
|
|
|
|
vmwNsxTDataCenterApplianceAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterApplianceAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX appliance's IP address. The value is an IPv4 address."
|
|
::= { vmwNsxTDataCenterData 25 }
|
|
|
|
vmwNsxTDataCenterCurrentGatewayState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCurrentGatewayStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active"
|
|
::= { vmwNsxTDataCenterData 26 }
|
|
|
|
vmwNsxTDataCenterCurrentServiceState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCurrentServiceStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current service state. The value could be start/stop/restart/crashed."
|
|
::= { vmwNsxTDataCenterData 27 }
|
|
|
|
vmwNsxTDataCenterDatapathResourceUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDatapathResourceUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU, memory, or disk usage percentage of the datapath on a NSX appliance.
|
|
The value is an integer between 0 and 100."
|
|
::= { vmwNsxTDataCenterData 28 }
|
|
|
|
vmwNsxTDataCenterDHCPPoolUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDHCPPoolUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of a DHCP pool. The value is an integer between 0 and 100."
|
|
::= { vmwNsxTDataCenterData 29 }
|
|
|
|
vmwNsxTDataCenterEdgeServiceName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeServiceNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running on the Edge node."
|
|
::= { vmwNsxTDataCenterData 30 }
|
|
|
|
vmwNsxTDataCenterFailureReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFailureReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The detailed reason of any module failure like BGP down, IKE down, etc."
|
|
::= { vmwNsxTDataCenterData 31 }
|
|
|
|
vmwNsxTDataCenterPreviousGatewayState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPreviousGatewayStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The previous gateway state. The value could be 0, 1 or 2 where 0 is down, 1 is standby and 2 is active"
|
|
::= { vmwNsxTDataCenterData 32 }
|
|
|
|
vmwNsxTDataCenterPreviousServiceState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPreviousServiceStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The previous service state. The value could be start/stop/restart/crashed."
|
|
::= { vmwNsxTDataCenterData 33 }
|
|
|
|
vmwNsxTDataCenterSystemUsageThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSystemUsageThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The configured threshold value for the CPU, memory, or disk usage
|
|
percentage of an NSX appliance. The value is an integer between 0 and
|
|
100."
|
|
::= { vmwNsxTDataCenterData 34 }
|
|
|
|
vmwNsxTDataCenterUsername OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterUsernameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of a user in an NSX appliance."
|
|
::= { vmwNsxTDataCenterData 35 }
|
|
|
|
vmwNsxTDataCenterDHCPServerId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDHCPServerIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The UUID of a DHCP server."
|
|
::= { vmwNsxTDataCenterData 36 }
|
|
|
|
vmwNsxTDataCenterServiceName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterServiceNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the service running in an NSX appliance."
|
|
::= { vmwNsxTDataCenterData 37 }
|
|
|
|
vmwNsxTDataCenterIntelligenceNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIntelligenceNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The node ID of an NSX Intelligence node."
|
|
::= { vmwNsxTDataCenterData 38 }
|
|
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterHostnameOrIPAddressWithPortType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 39 }
|
|
|
|
vmwNsxTDataCenterEventId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEventIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The event identifier."
|
|
::= { vmwNsxTDataCenterData 40 }
|
|
|
|
vmwNsxTDataCenterActiveGlobalManager OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterActiveGlobalManagerType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 41 }
|
|
|
|
vmwNsxTDataCenterActiveGlobalManagers OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterActiveGlobalManagersType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 42 }
|
|
|
|
vmwNsxTDataCenterSessionDownReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSessionDownReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Down reason of the IPsec VPN session."
|
|
::= { vmwNsxTDataCenterData 43 }
|
|
|
|
vmwNsxTDataCenterManagerNodeName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterManagerNodeNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 44 }
|
|
|
|
vmwNsxTDataCenterTransportNodeAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTransportNodeAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 45 }
|
|
|
|
vmwNsxTDataCenterTransportNodeName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTransportNodeNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 46 }
|
|
|
|
vmwNsxTDataCenterCentralControlPlaneId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCentralControlPlaneIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 47 }
|
|
|
|
vmwNsxTDataCenterTunnelDownReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTunnelDownReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Down reason of the IPsec VPN tunnel."
|
|
::= { vmwNsxTDataCenterData 48 }
|
|
|
|
vmwNsxTDataCenterHeapType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterHeapTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Heap type information for DFW memory usage like vsip-attr, vsip-flow, vsip-fqdni, etc."
|
|
::= { vmwNsxTDataCenterData 49 }
|
|
|
|
vmwNsxTDataCenterMempoolName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMempoolNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Name of a memory pool."
|
|
::= { vmwNsxTDataCenterData 50 }
|
|
|
|
vmwNsxTDataCenterPasswordExpirationDays OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPasswordExpirationDaysType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of days left before expiration of the password of an NSX
|
|
appliance user. The value is an integer greater than 0."
|
|
::= { vmwNsxTDataCenterData 51 }
|
|
|
|
vmwNsxTDataCenterBGPNeighborIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterBGPNeighborIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of BGP Neighbor. This could be either IPv4 or IPv6 address."
|
|
::= { vmwNsxTDataCenterData 52 }
|
|
|
|
vmwNsxTDataCenterLDAPServer OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLDAPServerType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 53 }
|
|
|
|
vmwNsxTDataCenterPeerAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPeerAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP address of BFD peer."
|
|
::= { vmwNsxTDataCenterData 54 }
|
|
|
|
vmwNsxTDataCenterMaxIDSEventsAllowed OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMaxIDSEventsAllowedType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 55 }
|
|
|
|
vmwNsxTDataCenterStaticAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterStaticAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Static IP address."
|
|
::= { vmwNsxTDataCenterData 56 }
|
|
|
|
vmwNsxTDataCenterDuplicateIPAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDuplicateIPAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Duplicate IP address."
|
|
::= { vmwNsxTDataCenterData 57 }
|
|
|
|
vmwNsxTDataCenterCapacityDisplayName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCapacityDisplayNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 58 }
|
|
|
|
vmwNsxTDataCenterCapacityUsageCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCapacityUsageCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 59 }
|
|
|
|
vmwNsxTDataCenterEdgeNICName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeNICNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The name of the NIC whose link is down or which faced tx/rx ring buffer overflow."
|
|
::= { vmwNsxTDataCenterData 60 }
|
|
|
|
vmwNsxTDataCenterRxRingBufferOverflowPercentage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRxRingBufferOverflowPercentageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC's receive descriptor ring buffer on a NSX Edge or Gateway node has no space left
|
|
to accomodate new incoming packets and there is a significant drop due to it.
|
|
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
|
|
::= { vmwNsxTDataCenterData 61 }
|
|
|
|
vmwNsxTDataCenterTxRingBufferOverflowPercentage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTxRingBufferOverflowPercentageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NIC's transmit descriptor ring buffer on a NSX Edge or Gateway node has no space left
|
|
to accomodate new outgoing packets and there is a significant drop due to it.
|
|
The value is a float between 0 to 100 describing the overflow percentage due to the packet drops."
|
|
::= { vmwNsxTDataCenterData 62 }
|
|
|
|
vmwNsxTDataCenterSrId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSrIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service Router UUID."
|
|
::= { vmwNsxTDataCenterData 63 }
|
|
|
|
vmwNsxTDataCenterIDSEventsCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIDSEventsCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 64 }
|
|
|
|
vmwNsxTDataCenterRemoteSiteName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRemoteSiteNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 65 }
|
|
|
|
vmwNsxTDataCenterBGPSourceIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterBGPSourceIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 66 }
|
|
|
|
vmwNsxTDataCenterRemoteSiteId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRemoteSiteIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 67 }
|
|
|
|
vmwNsxTDataCenterSiteId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSiteIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 68 }
|
|
|
|
vmwNsxTDataCenterSiteName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSiteNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 69 }
|
|
|
|
vmwNsxTDataCenterLrId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLrIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 70 }
|
|
|
|
vmwNsxTDataCenterRxMisses OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRxMissesType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 71 }
|
|
|
|
vmwNsxTDataCenterRxProcessed OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRxProcessedType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 72 }
|
|
|
|
vmwNsxTDataCenterTxMisses OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTxMissesType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 73 }
|
|
|
|
vmwNsxTDataCenterTxProcessed OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTxProcessedType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 74 }
|
|
|
|
vmwNsxTDataCenterLrportId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLrportIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Logical Router Port UUID."
|
|
::= { vmwNsxTDataCenterData 75 }
|
|
|
|
vmwNsxTDataCenterServiceIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterServiceIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Ip configured for the service running in an NSX appliance."
|
|
::= { vmwNsxTDataCenterData 77 }
|
|
|
|
vmwNsxTDataCenterRemoteManagerNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRemoteManagerNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 80 }
|
|
|
|
vmwNsxTDataCenterDirectoryDomain OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDirectoryDomainType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 81 }
|
|
|
|
vmwNsxTDataCenterTimeoutInMinutes OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTimeoutInMinutesType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 82 }
|
|
|
|
vmwNsxTDataCenterMaxCapacityThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMaxCapacityThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 83 }
|
|
|
|
vmwNsxTDataCenterMinCapacityThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMinCapacityThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 84 }
|
|
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMaxSupportedCapacityCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 85 }
|
|
|
|
vmwNsxTDataCenterLatencySource OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLatencySourceType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 86 }
|
|
|
|
vmwNsxTDataCenterLatencyThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLatencyThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 87 }
|
|
|
|
vmwNsxTDataCenterLatencyValue OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLatencyValueType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 88 }
|
|
|
|
vmwNsxTDataCenterApplianceFQDN OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterApplianceFQDNType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 89 }
|
|
|
|
vmwNsxTDataCenterRemoteApplianceAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRemoteApplianceAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 90 }
|
|
|
|
vmwNsxTDataCenterManagerNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterManagerNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 91 }
|
|
|
|
vmwNsxTDataCenterDisplayedLicenseKey OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDisplayedLicenseKeyType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 92 }
|
|
|
|
vmwNsxTDataCenterEdgeThreadName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeThreadNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 93 }
|
|
|
|
vmwNsxTDataCenterIntentPath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIntentPathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 94 }
|
|
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallHalfopenFlowUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firewall TCP half-open connection usage."
|
|
::= { vmwNsxTDataCenterData 95 }
|
|
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallICMPFlowUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firewall ICMP connection usage."
|
|
::= { vmwNsxTDataCenterData 96 }
|
|
|
|
vmwNsxTDataCenterServiceDownReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterServiceDownReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 97 }
|
|
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallUDPFlowUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firewall UDP connection usage."
|
|
::= { vmwNsxTDataCenterData 98 }
|
|
|
|
vmwNsxTDataCenterFirewallIPFlowUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallIPFlowUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Firewall IP connection usage."
|
|
::= { vmwNsxTDataCenterData 99 }
|
|
|
|
vmwNsxTDataCenterDNSId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDNSIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder identifier."
|
|
::= { vmwNsxTDataCenterData 100 }
|
|
|
|
vmwNsxTDataCenterDNSUpstreamIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDNSUpstreamIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder upstream server IP address."
|
|
::= { vmwNsxTDataCenterData 101 }
|
|
|
|
vmwNsxTDataCenterCABundleAgeThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCABundleAgeThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 121 }
|
|
|
|
vmwNsxTDataCenterAPICollectionPath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterAPICollectionPathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 122 }
|
|
|
|
vmwNsxTDataCenterEdgeNodeSettingMismatchReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeNodeSettingMismatchReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 123 }
|
|
|
|
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 124 }
|
|
|
|
vmwNsxTDataCenterFirewallSNATPortsUsage OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFirewallSNATPortsUsageType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 125 }
|
|
|
|
vmwNsxTDataCenterEdgevSphereLocationMismatchReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgevSphereLocationMismatchReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 126 }
|
|
|
|
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 127 }
|
|
|
|
vmwNsxTDataCenterSNATIPAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSNATIPAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 128 }
|
|
|
|
vmwNsxTDataCenterNappClusterId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappClusterIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 129 }
|
|
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappMessagingLAGThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 130 }
|
|
|
|
vmwNsxTDataCenterNappNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 131 }
|
|
|
|
vmwNsxTDataCenterNappServiceName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappServiceNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 132 }
|
|
|
|
vmwNsxTDataCenterFlowIdentifier OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFlowIdentifierType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 133 }
|
|
|
|
vmwNsxTDataCenterSyncIssueReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSyncIssueReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 134 }
|
|
|
|
vmwNsxTDataCenterQueueName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterQueueNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 135 }
|
|
|
|
vmwNsxTDataCenterQueueSize OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterQueueSizeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 136 }
|
|
|
|
vmwNsxTDataCenterQueueSizeThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterQueueSizeThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 137 }
|
|
|
|
vmwNsxTDataCenterGroupType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterGroupTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 138 }
|
|
|
|
vmwNsxTDataCenterManagerNodeIDS OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterManagerNodeIDSType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 139 }
|
|
|
|
vmwNsxTDataCenterServiceRouterId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterServiceRouterIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 140 }
|
|
|
|
vmwNsxTDataCenterTransportNodeId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTransportNodeIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 141 }
|
|
|
|
vmwNsxTDataCenterFromGMPath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFromGMPathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 142 }
|
|
|
|
vmwNsxTDataCenterToGMPath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterToGMPathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 143 }
|
|
|
|
vmwNsxTDataCenterNICThroughput OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNICThroughputType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 144 }
|
|
|
|
vmwNsxTDataCenterNICThroughputThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNICThroughputThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 145 }
|
|
|
|
vmwNsxTDataCenterEdgeCryptoDrvName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeCryptoDrvNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 146 }
|
|
|
|
vmwNsxTDataCenterNappNodeName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNappNodeNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 147 }
|
|
|
|
vmwNsxTDataCenterNewVMMorefId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNewVMMorefIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 148 }
|
|
|
|
vmwNsxTDataCenterPolicyEdgeVMName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPolicyEdgeVMNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 149 }
|
|
|
|
vmwNsxTDataCenterVMMorefId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterVMMorefIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 150 }
|
|
|
|
vmwNsxTDataCenterDPUId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDPUIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 171 }
|
|
|
|
vmwNsxTDataCenterEdgeNode OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeNodeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 172 }
|
|
|
|
vmwNsxTDataCenterPrefixesCountMax OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPrefixesCountMaxType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 173 }
|
|
|
|
vmwNsxTDataCenterPrefixesCountThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterPrefixesCountThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 174 }
|
|
|
|
vmwNsxTDataCenterRouteLimitMaximum OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRouteLimitMaximumType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 175 }
|
|
|
|
vmwNsxTDataCenterRouteLimitThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterRouteLimitThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 176 }
|
|
|
|
vmwNsxTDataCenterSubsequentAddressFamily OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSubsequentAddressFamilyType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 177 }
|
|
|
|
vmwNsxTDataCentervCenterClusterId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCentervCenterClusterIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 179 }
|
|
|
|
vmwNsxTDataCenterMpsServiceName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMpsServiceNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 180 }
|
|
|
|
vmwNsxTDataCenterMemberIndexId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMemberIndexIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 182 }
|
|
|
|
vmwNsxTDataCenterEdgeClusterId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeClusterIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 184 }
|
|
|
|
vmwNsxTDataCenterCoreDumpCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCoreDumpCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 185 }
|
|
|
|
vmwNsxTDataCenterNodeDisplayOrHostName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNodeDisplayOrHostNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 186 }
|
|
|
|
vmwNsxTDataCenterNSXEdgeTNName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNSXEdgeTNNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 187 }
|
|
|
|
vmwNsxTDataCenterNSXESXTNName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNSXESXTNNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 188 }
|
|
|
|
vmwNsxTDataCenterCollectorIP OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCollectorIPType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 189 }
|
|
|
|
vmwNsxTDataCenterDvsAlias OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDvsAliasType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 190 }
|
|
|
|
vmwNsxTDataCenterStackAlias OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterStackAliasType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 191 }
|
|
|
|
vmwNsxTDataCenterVerticalName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterVerticalNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 192 }
|
|
|
|
vmwNsxTDataCenterEdgeClusterHighestHwVersion OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeClusterHighestHwVersionType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 195 }
|
|
|
|
vmwNsxTDataCenterEdgeTNHwVersion OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeTNHwVersionType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 196 }
|
|
|
|
vmwNsxTDataCenterEdgeClusterName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterEdgeClusterNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 197 }
|
|
|
|
vmwNsxTDataCenterHaState OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterHaStateType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 220 }
|
|
|
|
vmwNsxTDataCenterHaState2 OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterHaState2Type
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 221 }
|
|
|
|
vmwNsxTDataCenterTransportNodeId2 OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTransportNodeId2Type
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 222 }
|
|
|
|
vmwNsxTDataCenterDvsName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterDvsNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 223 }
|
|
|
|
vmwNsxTDataCenterVtepFaultReason OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterVtepFaultReasonType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 224 }
|
|
|
|
vmwNsxTDataCenterVtepName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterVtepNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 225 }
|
|
|
|
vmwNsxTDataCenterMetricsTargetAddress OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMetricsTargetAddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 226 }
|
|
|
|
vmwNsxTDataCenterMetricsTargetAlias OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMetricsTargetAliasType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 227 }
|
|
|
|
vmwNsxTDataCenterMetricsTargetPort OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMetricsTargetPortType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 228 }
|
|
|
|
vmwNsxTDataCenterIPv4Address OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIPv4AddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 229 }
|
|
|
|
vmwNsxTDataCenterIPv6Address OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIPv6AddressType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 230 }
|
|
|
|
vmwNsxTDataCenterConstraintLimit OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterConstraintLimitType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 231 }
|
|
|
|
vmwNsxTDataCenterConstraintType OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterConstraintTypeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 232 }
|
|
|
|
vmwNsxTDataCenterCurrentCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCurrentCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 233 }
|
|
|
|
vmwNsxTDataCenterGroupId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterGroupIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 234 }
|
|
|
|
vmwNsxTDataCenterGroupMaxNumberLimit OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterGroupMaxNumberLimitType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 235 }
|
|
|
|
vmwNsxTDataCenterGroupSize OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterGroupSizeType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 236 }
|
|
|
|
vmwNsxTDataCenterIPCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterIPCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 237 }
|
|
|
|
vmwNsxTDataCenterLrpCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLrpCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 238 }
|
|
|
|
vmwNsxTDataCenterLspCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterLspCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 239 }
|
|
|
|
vmwNsxTDataCenterMacCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterMacCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 240 }
|
|
|
|
vmwNsxTDataCenterSidCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterSidCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 241 }
|
|
|
|
vmwNsxTDataCenterTNCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterTNCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 244 }
|
|
|
|
vmwNsxTDataCenterVifCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterVifCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 245 }
|
|
|
|
vmwNsxTDataCenterVMCount OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterVMCountType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 246 }
|
|
|
|
vmwNsxTDataCenterCoreId OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterCoreIdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 247 }
|
|
|
|
vmwNsxTDataCenterFlowCacheThreshold OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterFlowCacheThresholdType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 248 }
|
|
|
|
vmwNsxTDataCenterNSXaaSServiceName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterNSXaaSServiceNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 249 }
|
|
|
|
vmwNsxTDataCenterProtocolName OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterProtocolNameType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 250 }
|
|
|
|
vmwNsxTDataCenterConstraintTypePath OBJECT-TYPE
|
|
SYNTAX VmwNsxTDataCenterConstraintTypePathType
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This value is not expected to be empty."
|
|
::= { vmwNsxTDataCenterData 251 }
|
|
|
|
-- **********************************************************
|
|
-- AlarmManagement feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTAlarmManagementFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the AlarmManagement feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 16 }
|
|
|
|
vmwNsxTAlarmManagementFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for AlarmManagement feature notifications.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeaturePrefix 0 }
|
|
|
|
vmwNsxTAlarmManagementAlarmServiceOverloaded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Due to heavy volume of alarms reported, the alarm service is temporarily
|
|
overloaded. The NSX UI and GET /api/v1/alarms NSX API have stopped
|
|
reporting new alarms; however, syslog entries and SNMP traps (if enabled)
|
|
are still being emitted reporting the underlying event details. When the
|
|
underlying issues causing the heavy volume of alarms are addressed, the
|
|
alarm service will start reporting new alarms again.
|
|
|
|
Action required:
|
|
Review all active alarms using the Alarms page in the NSX UI or using the
|
|
GET /api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED NSX API. For each
|
|
active alarm investigate the root cause by following the recommended action
|
|
for the alarm. When sufficient alarms are resolved, the alarm service will
|
|
start reporting new alarms again.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeature 1 }
|
|
|
|
vmwNsxTAlarmManagementAlarmServiceOverloadedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The heavy volume of alarms has subsided and new alarms are being reported
|
|
again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeature 2 }
|
|
|
|
vmwNsxTAlarmManagementHeavyVolumeOfAlarms NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEventId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Due to heavy volume of vmwNsxTDataCenterEventId alarms, the alarm service has
|
|
temporarily stopped reporting alarms of this type. The NSX UI and
|
|
GET /api/v1/alarms NSX API are not reporting new instances of these
|
|
alarms; however, syslog entries and SNMP traps (if enabled) are
|
|
still being emitted reporting the underlying event details. When the
|
|
underlying issues causing the heavy volume of vmwNsxTDataCenterEventId alarms are
|
|
addressed, the alarm service will start reporting new vmwNsxTDataCenterEventId
|
|
alarms when new issues are detected again.
|
|
|
|
Action required:
|
|
Review all active alarms of type vmwNsxTDataCenterEventId using the
|
|
Alarms page in the NSX UI or using the NSX API GET
|
|
/api/v1/alarms?status=OPEN,ACKNOWLEDGED,SUPPRESSED. For each active
|
|
alarm investigate the root cause by following the recommended action
|
|
for the alarm. When sufficient alarms are resolved, the alarm service
|
|
will start reporting new vmwNsxTDataCenterEventId alarms again.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeature 3 }
|
|
|
|
vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEventId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The heavy volume of vmwNsxTDataCenterEventId alarms has subsided and new alarms of
|
|
this type are being reported again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTAlarmManagementFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- AuditLogHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTAuditLogHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the AuditLogHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 24 }
|
|
|
|
vmwNsxTAuditLogHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for AuditLogHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTAuditLogHealthAuditLogFileUpdateError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At least one of the monitored log files has read-only permissions or has
|
|
incorrect user/group ownership on Manager, Global Manager, Edge, Public
|
|
Cloud Gateway, KVM or Linux Physical Server nodes. Or log folder is
|
|
missing in Windows Physical Server nodes. Or rsyslog.log is
|
|
missing on Manager, Global Manager, Edge or Public Cloud Gateway nodes.
|
|
|
|
Action required:
|
|
1. On Manager and Global Managaer nodes, Edge and Public Cloud Gateway
|
|
nodes, Ubuntu KVM Host nodes ensure the permissions for the /var/log
|
|
directory is 775 and the ownership is root:syslog. One Rhel KVM and BMS
|
|
Host nodes ensure the permission for the /var/log directory is 755 and
|
|
the ownership is root:root.
|
|
2. On Manager and Global Manager nodes, ensure the file permissions
|
|
for auth.log, nsx-audit.log, nsx-audit-write.log, rsyslog.log and syslog
|
|
under /var/log is 640 and ownership is syslog:admin.
|
|
3. On Edge and Public Cloud Gateway nodes, ensure the file permissions
|
|
for rsyslog.log and syslog under /var/log is 640 and ownership is
|
|
syslog:admin.
|
|
4. On Ubuntu KVM Host and Ubuntu Physical Server nodes, ensure the
|
|
file permissions of auth.log and vmware/nsx-syslog under /var/log is
|
|
640 and ownership is syslog:admin.
|
|
5. On Rhel KVM Host nodes and Centos/Rhel/Sles Physical Server nodes,
|
|
ensure the file permission of vmware/nsx-syslog under /var/log is 640
|
|
and ownership is root:root.
|
|
6. If any of these files have incorrect permissions or ownership, invoke
|
|
the commands `chmod <mode> <path>` and `chown <user>:<group> <path>`.
|
|
7. If rsyslog.log is missing on Manager, Global Manager, Edge or Public
|
|
Cloud Gateway nodes, invoke the NSX CLI command `restart service syslog`
|
|
which restarts the logging service and regenerates /var/log/rsyslog.log.
|
|
8. On Windows Physical Server nodes, ensure the log folder:
|
|
C:\ProgramData\VMware\NSX\Logs exists. If not, re-install NSX on the
|
|
Windows Physical Server nodes.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeature 1 }
|
|
|
|
vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All monitored log files have the correct file permissions and ownership
|
|
and rsyslog.log exists on Manager, Global Manager, Edge or Public
|
|
Cloud Gateway nodes.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeature 2 }
|
|
|
|
vmwNsxTAuditLogHealthRemoteLoggingServerError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Log messages to logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId)
|
|
cannot be delivered possibly due to an unresolvable FQDN, an invalid TLS
|
|
certificate or missing NSX appliance iptables rule.
|
|
|
|
Action required:
|
|
1. Ensure that vmwNsxTDataCenterHostnameOrIPAddressWithPort is the correct hostname or
|
|
IP address and port.
|
|
2. If the logging server is specified using a FQDN, ensure the FQDN is resolvable
|
|
from the NSX appliance using the NSX CLI command `nslookup <fqdn>`. If not
|
|
resolvable, verify the correct FQDN is specified and the network DNS server has
|
|
the required entry for the FQDN.
|
|
3. If the logging server is configured to use TLS, verify the specified certificate
|
|
is valid. For example, ensure the logging server is actually using the certificate
|
|
or verify the certificate has not expired using the openssl command
|
|
`openssl x509 -in <cert-file-path> -noout -dates`.
|
|
4. NSX appliances use iptables rules to explicitly allow outgoing traffic. Verify
|
|
the iptables rule for the logging server is configured properly by invoking the
|
|
NSX CLI command `verify logging-servers` which re-configures logging server
|
|
iptables rules as needed.
|
|
5. If for any reason the logging server is misconfigured, it should be deleted
|
|
using the NSX CLI `del logging-server <hostname-or-ip-address[:port]>
|
|
proto <proto> level <level>` command and re-added with the correct configuration.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeature 3 }
|
|
|
|
vmwNsxTAuditLogHealthRemoteLoggingServerErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration for logging server vmwNsxTDataCenterHostnameOrIPAddressWithPort (vmwNsxTDataCenterEntityId)
|
|
appear correct.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTAuditLogHealthFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- Capacity feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTCapacityFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Capacity feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 22 }
|
|
|
|
vmwNsxTCapacityFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Capacity feature notifications.
|
|
"
|
|
::= { vmwNsxTCapacityFeaturePrefix 0 }
|
|
|
|
vmwNsxTCapacityMaximumCapacity NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum supported
|
|
count of vmwNsxTDataCenterMaxSupportedCapacityCount.
|
|
|
|
Action required:
|
|
Ensure that the number of NSX objects created is within the limits
|
|
supported by NSX. If there are any unused objects, delete them using the
|
|
respective NSX UI or API from the system.
|
|
Consider increasing the form factor of all Manager nodes and/or Edge
|
|
nodes. Note that the form factor of each node type should be the
|
|
same. If not the same, the capacity limits for the lowest form factor
|
|
deployed are used.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 1 }
|
|
|
|
vmwNsxTCapacityMaximumCapacityClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum supported count of
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 2 }
|
|
|
|
vmwNsxTCapacityMaximumCapacityThreshold NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMaxCapacityThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount which is above the maximum capacity
|
|
threshold of vmwNsxTDataCenterMaxCapacityThreshold%.
|
|
|
|
Action required:
|
|
Navigate to the capacity page in the NSX UI and review current usage versus
|
|
threshold limits. If the current usage is expected, consider increasing the
|
|
maximum threshold values. If the current usage is unexpected, review the
|
|
network policies configured to decrease usage at or below the maximum threshold.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 3 }
|
|
|
|
vmwNsxTCapacityMaximumCapacityThresholdClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMaxCapacityThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the maximum capacity threshold
|
|
of vmwNsxTDataCenterMaxCapacityThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 4 }
|
|
|
|
vmwNsxTCapacityMinimumCapacityThreshold NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMinCapacityThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount which is above the minimum capacity
|
|
threshold of vmwNsxTDataCenterMinCapacityThreshold%.
|
|
|
|
Action required:
|
|
Navigate to the capacity page in the NSX UI and review current usage versus
|
|
threshold limits. If the current usage is expected, consider increasing the
|
|
minimum threshold values. If the current usage is unexpected, review the
|
|
network policies configured to decrease usage at or below the minimum threshold.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 5 }
|
|
|
|
vmwNsxTCapacityMinimumCapacityThresholdClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterMinCapacityThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of objects defined in the system for vmwNsxTDataCenterCapacityDisplayName has
|
|
reached vmwNsxTDataCenterCapacityUsageCount and is at or below the minimum capacity threshold
|
|
of vmwNsxTDataCenterMinCapacityThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCapacityFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- Certificates feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTCertificatesFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Certificates feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 3 }
|
|
|
|
vmwNsxTCertificatesFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Certificates feature notifications.
|
|
"
|
|
::= { vmwNsxTCertificatesFeaturePrefix 0 }
|
|
|
|
vmwNsxTCertificatesCABundleUpdateRecommended NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCABundleAgeThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than
|
|
vmwNsxTDataCenterCABundleAgeThreshold days ago.
|
|
Update for the trusted CA bundle is recommended.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the trusted CA bundle are updated
|
|
to use a recently-updated trusted CA bundle. Unless it is system-provided
|
|
bundle, the bundle can be updated using the
|
|
PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
|
|
Once the expired bundle is no longer in use, it should be deleted (if not
|
|
system-provided) by invoking the
|
|
DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 7 }
|
|
|
|
vmwNsxTCertificatesCABundleUpdateRecommendedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer
|
|
in use.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 8 }
|
|
|
|
vmwNsxTCertificatesCABundleUpdateSuggested NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterCABundleAgeThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trusted CA bundle vmwNsxTDataCenterEntityId was updated more than
|
|
vmwNsxTDataCenterCABundleAgeThreshold days ago.
|
|
Update for the trusted CA bundle is suggested.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the trusted CA bundle are updated
|
|
to use a recently-updated trusted CA bundle. Unless it is system-provided
|
|
bundle, the bundle can be updated using the
|
|
PUT /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
|
|
Once the expired bundle is no longer in use, it should be deleted (if not
|
|
system-provided) by invoking the
|
|
DELETE /policy/api/v1/infra/cabundles/vmwNsxTDataCenterEntityId NSX API.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 9 }
|
|
|
|
vmwNsxTCertificatesCABundleUpdateSuggestedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trusted CA bundle vmwNsxTDataCenterEntityId has been removed, updated, or is no longer
|
|
in use.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 10 }
|
|
|
|
vmwNsxTCertificatesCertificateExpirationApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterAPICollectionPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate vmwNsxTDataCenterEntityId is approaching expiration.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the certificate are updated
|
|
to use a new, non-expiring certificate. Once the expiring
|
|
certificate is no longer in use, it should be deleted by invoking the
|
|
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 1 }
|
|
|
|
vmwNsxTCertificatesCertificateExpirationApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer
|
|
approaching expiration.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 2 }
|
|
|
|
vmwNsxTCertificatesCertificateExpired NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterAPICollectionPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate vmwNsxTDataCenterEntityId has expired.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the certificate are updated
|
|
to use a new, non-expired certificate. Once the expired
|
|
certificate is no longer in use, it should be deleted by invoking the
|
|
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
|
|
If the expired certificate is used by NAPP Platform,
|
|
the connection is broken between NSX and NAPP Platform.
|
|
Check the NAPP Platform troubleshooting document
|
|
to use a self-signed NAPP CA certificate for recovering the connection.
|
|
|
|
For more information see:
|
|
https://www.vmware.com/esx/support/askvmware/index.php?eventtype=certificates.certificate_expired
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 3 }
|
|
|
|
vmwNsxTCertificatesCertificateExpiredClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expired certificate vmwNsxTDataCenterEntityId has been removed or is no longer
|
|
expired.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 4 }
|
|
|
|
vmwNsxTCertificatesCertificateIsAboutToExpire NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterAPICollectionPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate vmwNsxTDataCenterEntityId is about to expire.
|
|
|
|
Action required:
|
|
Ensure services that are currently using the certificate are updated
|
|
to use a new, non-expiring certificate. Once the expiring
|
|
certificate is no longer in use, it should be deleted by invoking the
|
|
DELETE vmwNsxTDataCenterAPICollectionPathvmwNsxTDataCenterEntityId NSX API.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 5 }
|
|
|
|
vmwNsxTCertificatesCertificateIsAboutToExpireClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expiring certificate vmwNsxTDataCenterEntityId has been removed or is no longer
|
|
about to expire.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 6 }
|
|
|
|
vmwNsxTCertificatesTransportNodeCertificateExpirApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate for Transport node vmwNsxTDataCenterEntityId is approaching expiration.
|
|
|
|
Action required:
|
|
Replace the Transport node vmwNsxTDataCenterEntityId certificate
|
|
with a non-expired certificate. The expired
|
|
certificate should be replaced by invoking the
|
|
POST /api/v1/trust-management/certificates/action/replace-host-certificate/vmwNsxTDataCenterEntityId NSX API.
|
|
If the certificate is not replaced, when the certificate expires the connection between
|
|
the Transport node and the Manager node will be broken.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 17 }
|
|
|
|
vmwNsxTCertificatesTransportNodeCertificateExpirApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expiring certificate for Transport node vmwNsxTDataCenterEntityId has been removed or is no longer
|
|
approaching expiration.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 18 }
|
|
|
|
vmwNsxTCertificatesTransportNodeCertificateExpired NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate has expired for Transport node vmwNsxTDataCenterEntityId.
|
|
|
|
Action required:
|
|
Replace the Transport node vmwNsxTDataCenterEntityId certificate
|
|
with a non-expired certificate. The expired
|
|
certificate should be replaced by invoking the
|
|
POST /api/v1/trust-management/certificates/action/replace-host-certificate/vmwNsxTDataCenterEntityId NSX API.
|
|
If the expired certificate is used by Transport node,
|
|
the connection is broken between Transport node and Manager node.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 19 }
|
|
|
|
vmwNsxTCertificatesTransportNodeCertificateExpiredClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expired certificate for Transport node vmwNsxTDataCenterEntityId has been replaced or is no longer
|
|
expired.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 20 }
|
|
|
|
vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpire NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Certificate for Transport node vmwNsxTDataCenterEntityId is about to expire.
|
|
|
|
Action required:
|
|
Replace the Transport node vmwNsxTDataCenterEntityId certificate
|
|
with a non-expired certificate. The expired
|
|
certificate should be replaced by invoking the
|
|
POST /api/v1/trust-management/certificates/action/replace-host-certificate/vmwNsxTDataCenterEntityId NSX API.
|
|
If the certificate is not replaced, when the certificate expires the connection between
|
|
the Transport node and the Manager node will be broken.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 21 }
|
|
|
|
vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpireClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expiring certificate for Transport node vmwNsxTDataCenterEntityId has been removed or is no longer
|
|
about to expire.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCertificatesFeature 22 }
|
|
|
|
-- **********************************************************
|
|
-- Clustering feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTClusteringFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Clustering feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 40 }
|
|
|
|
vmwNsxTClusteringFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Clustering feature notifications.
|
|
"
|
|
::= { vmwNsxTClusteringFeaturePrefix 0 }
|
|
|
|
vmwNsxTClusteringClusterDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterGroupType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group member vmwNsxTDataCenterManagerNodeId of service vmwNsxTDataCenterGroupType is down.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command 'get cluster status' to view the status
|
|
of group members of the cluster.
|
|
2. Ensure the service for vmwNsxTDataCenterGroupType is running on node. Invoke the GET
|
|
/api/v1/node/services/<service_name>/status NSX API or the
|
|
`get service <service_name>` NSX CLI command to determine if the service is running.
|
|
If not running, invoke the POST /api/v1/node/services/<service_name>?action=restart NSX API or
|
|
the `restart service <service_name>` NSX CLI to restart the service.
|
|
3. Check /var/log/ of service vmwNsxTDataCenterGroupType to see if there are errors reported.
|
|
"
|
|
::= { vmwNsxTClusteringFeature 1 }
|
|
|
|
vmwNsxTClusteringClusterDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterGroupType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group member vmwNsxTDataCenterManagerNodeId of vmwNsxTDataCenterGroupType is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTClusteringFeature 2 }
|
|
|
|
vmwNsxTClusteringClusterUnavailable NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeIDS,
|
|
vmwNsxTDataCenterGroupType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are down.
|
|
|
|
Action required:
|
|
1. Ensure the service for vmwNsxTDataCenterGroupType is running on node. Invoke the GET
|
|
/api/v1/node/services/<service_name>/status NSX API or the
|
|
`get service <service_name>` NSX CLI command to determine if the service is running.
|
|
If not running, invoke the POST /api/v1/node/services/<service_name>?action=restart NSX API or
|
|
the `restart service <service_name>` NSX CLI to restart the service.
|
|
2. Check /var/log/ of service vmwNsxTDataCenterGroupType to see if there are errors reported.
|
|
"
|
|
::= { vmwNsxTClusteringFeature 3 }
|
|
|
|
vmwNsxTClusteringClusterUnavailableClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeIDS,
|
|
vmwNsxTDataCenterGroupType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All group members vmwNsxTDataCenterManagerNodeIDS of service vmwNsxTDataCenterGroupType are up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTClusteringFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- CniHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTCniHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the CniHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 10 }
|
|
|
|
vmwNsxTCniHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for CniHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTCniHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hyperbus cannot communicate with the Manager node.
|
|
|
|
Action required:
|
|
The hyperbus vmkernel interface (vmk50) may be missing. Refer to
|
|
Knowledge Base article https://kb.vmware.com/s/article/67432.
|
|
"
|
|
::= { vmwNsxTCniHealthFeature 3 }
|
|
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hyperbus can communicate with the Manager node.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCniHealthFeature 4 }
|
|
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDownOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hyperbus on DPU vmwNsxTDataCenterDPUId cannot communicate with the Manager node.
|
|
|
|
Action required:
|
|
The hyperbus vmkernel interface (vmk50) on DPU vmwNsxTDataCenterDPUId may be missing. Refer to
|
|
Knowledge Base article https://kb.vmware.com/s/article/67432.
|
|
"
|
|
::= { vmwNsxTCniHealthFeature 5 }
|
|
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDownOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Hyperbus on DPU vmwNsxTDataCenterDPUId can communicate with the Manager node.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCniHealthFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- Communication feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTCommunicationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Communication feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 35 }
|
|
|
|
vmwNsxTCommunicationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Communication feature notifications.
|
|
"
|
|
::= { vmwNsxTCommunicationFeaturePrefix 0 }
|
|
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterTimeoutInMinutes
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is
|
|
down for at least vmwNsxTDataCenterTimeoutInMinutes minutes from the Transport node's point of view.
|
|
|
|
Action required:
|
|
1. Check the connectivity from Transport node vmwNsxTDataCenterEntityId to Manager node vmwNsxTDataCenterApplianceAddress
|
|
interface via ping. If they are not pingable, check for flakiness in network connectivity.
|
|
2. Check to see if the TCP connections are established using the netstat output to see if the
|
|
Controller service on the Manager node vmwNsxTDataCenterApplianceAddress is listening for connections on port
|
|
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
|
|
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
|
|
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
|
|
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
|
|
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
|
|
You can check whether the Transport node is in maintenance mode via the following API:
|
|
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>
|
|
When maintenance mode is set, the Transport node will not be connected to the Controller
|
|
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
|
|
check connectivity again.
|
|
Note: This alarm is not critical and should be resolved. GSS need not be contacted for the
|
|
notification of this alarm unless the alarm remains unresolved over an extended period of time.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 7 }
|
|
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node
|
|
vmwNsxTDataCenterApplianceAddress.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 8 }
|
|
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLong NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterTimeoutInMinutes
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node vmwNsxTDataCenterEntityId control plane connection to Manager node vmwNsxTDataCenterApplianceAddress is
|
|
down for at least vmwNsxTDataCenterTimeoutInMinutes minutes from the Transport node's point of view.
|
|
|
|
Action required:
|
|
1. Check the connectivity from Transport node vmwNsxTDataCenterEntityId to Manager node vmwNsxTDataCenterApplianceAddress
|
|
interface via ping. If they are not pingable, check for flakiness in network connectivity.
|
|
2. Check to see if the TCP connections are established using the netstat output to see if the
|
|
Controller service on the Manager node vmwNsxTDataCenterApplianceAddress is listening for connections on port
|
|
1235. If not, check firewall (or) iptables rules to see if port 1235 is blocking Transport node
|
|
vmwNsxTDataCenterEntityId connection requests. Ensure that there are no host firewalls or network firewalls in
|
|
the underlay are blocking the required IP ports between Manager nodes and Transport nodes.
|
|
This is documented in our ports and protocols tool which is here: https://ports.vmware.com/.
|
|
3. It is possible that the Transport node vmwNsxTDataCenterEntityId may still be in maintenance mode.
|
|
You can check whether the Transport node is in maintenance mode via the following API:
|
|
GET https://<nsx-mgr>/api/v1/transport-nodes/<tn-uuid>.
|
|
When maintenance mode is set, the Transport node will not be connected to the Controller
|
|
service. This is usually the case when host upgrade is in progress. Wait for a few minutes and
|
|
check connectivity again.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 9 }
|
|
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Transport node vmwNsxTDataCenterEntityId restores the control plane connection to Manager node
|
|
vmwNsxTDataCenterApplianceAddress.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 10 }
|
|
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterCentralControlPlaneId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) to Transport
|
|
node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) down for at least three minutes from Controller service's point of view.
|
|
|
|
Action required:
|
|
1. Check the connectivity from the Controller service vmwNsxTDataCenterCentralControlPlaneId and
|
|
Transport node vmwNsxTDataCenterEntityId interface via ping and traceroute. This can be done on the NSX
|
|
Manager node admin CLI. The ping test should not see drops and have consistent latency values.
|
|
VMware recommends latency values of 150ms or less.
|
|
2. Navigate to System | Fabric | Nodes | Transport node vmwNsxTDataCenterEntityId on the NSX UI to check if
|
|
the TCP connections between the Controller service on Manager node vmwNsxTDataCenterApplianceAddress
|
|
(vmwNsxTDataCenterCentralControlPlaneId) and Transport node vmwNsxTDataCenterEntityId is established. If not, check
|
|
firewall rules on the network and the hosts to see if port 1235 is blocking Transport node vmwNsxTDataCenterEntityId
|
|
connection requests. Ensure that there are no host firewalls or network firewalls in the
|
|
underlay are blocking the required IP ports between Manager nodes and Transport nodes. This is
|
|
documented in our ports and protocols tool which is here: https://ports.vmware.com/.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 11 }
|
|
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterCentralControlPlaneId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) restores
|
|
connection to Transport node vmwNsxTDataCenterEntityId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 12 }
|
|
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownLong NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterCentralControlPlaneId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) to Transport
|
|
node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) down for at least 15 minutes from Controller service's point of view.
|
|
|
|
Action required:
|
|
1. Check the connectivity from the Controller service vmwNsxTDataCenterCentralControlPlaneId and
|
|
Transport node vmwNsxTDataCenterEntityId interface via ping and traceroute. This can be done on the NSX
|
|
Manager node admin CLI. The ping test should not see drops and have consistent latency values.
|
|
VMware recommends latency values of 150ms or less.
|
|
2. Navigate to System | Fabric | Nodes | Transport node vmwNsxTDataCenterEntityId on the NSX UI to check if
|
|
the TCP connections between the Controller service on Manager node vmwNsxTDataCenterApplianceAddress
|
|
(vmwNsxTDataCenterCentralControlPlaneId) and Transport node vmwNsxTDataCenterEntityId is established. If not, check
|
|
firewall rules on the network and the hosts to see if port 1235 is blocking Transport node vmwNsxTDataCenterEntityId
|
|
connection requests. Ensure that there are no host firewalls or network firewalls in the
|
|
underlay are blocking the required IP ports between Manager nodes and Transport nodes. This is
|
|
documented in our ports and protocols tool which is here: https://ports.vmware.com/.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 19 }
|
|
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownLongClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterCentralControlPlaneId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Controller service on Manager node vmwNsxTDataCenterApplianceAddress (vmwNsxTDataCenterCentralControlPlaneId) restores
|
|
connection to Transport node vmwNsxTDataCenterEntityId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 20 }
|
|
|
|
vmwNsxTCommunicationLimitedReachabilityOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVerticalName,
|
|
vmwNsxTDataCenterCollectorIP,
|
|
vmwNsxTDataCenterStackAlias,
|
|
vmwNsxTDataCenterDvsAlias,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can not be reached via vmknic(s)(stack vmwNsxTDataCenterStackAlias)
|
|
on DVS vmwNsxTDataCenterDvsAlias on DPU vmwNsxTDataCenterDPUId, but is reachable via vmknic(s)(stack vmwNsxTDataCenterStackAlias)
|
|
on other DVS(es).
|
|
|
|
Action required:
|
|
If the warning is on, it does not mean the collector is unreachable. The exported flows
|
|
generated by the vertical based on DVS vmwNsxTDataCenterDvsAlias can still reach the collector
|
|
vmwNsxTDataCenterCollectorIP via vmknic(s) on DVS(es) besides of DVS vmwNsxTDataCenterDvsAlias. If this is unacceptable,
|
|
user can try to create vmknic(s) with stack vmwNsxTDataCenterStackAlias on DVS vmwNsxTDataCenterDvsAlias and
|
|
configure it with approriate IPv4(6) address, then check if the vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP
|
|
can be reached via the newly-created vmknic(s) on DPU vmwNsxTDataCenterDPUId by invoking
|
|
`vmkping vmwNsxTDataCenterCollectorIP -S vmwNsxTDataCenterStackAlias -I vmkX` with SSH to DPU via ESXi enabled.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 31 }
|
|
|
|
vmwNsxTCommunicationLimitedReachabilityOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVerticalName,
|
|
vmwNsxTDataCenterCollectorIP,
|
|
vmwNsxTDataCenterStackAlias,
|
|
vmwNsxTDataCenterDvsAlias,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can be reached via vmknic(s) (stack vmwNsxTDataCenterStackAlias) on
|
|
DVS vmwNsxTDataCenterDvsAlias on DPU vmwNsxTDataCenterDPUId, or the vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP is unreachable completely.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 32 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
|
|
(vmwNsxTDataCenterApplianceAddress) is down for 5 minutes.
|
|
|
|
Action required:
|
|
Ensure there is network connectivity between the
|
|
Transport node vmwNsxTDataCenterTransportNodeId
|
|
and master Manager node. Also ensure no firewalls are blocking traffic
|
|
between the nodes. Ensure the messaging manager service is running on
|
|
Manager nodes by invoking the command `/etc/init.d/messaging-manager status`.
|
|
If the messaging manager is not running, restart it by
|
|
invoking the command `/etc/init.d/messaging-manager restart`.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 13 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
|
|
(vmwNsxTDataCenterApplianceAddress) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 14 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownLong NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
|
|
(vmwNsxTDataCenterApplianceAddress) is down for 15 minutes.
|
|
|
|
Action required:
|
|
Ensure there is network connectivity between the
|
|
Transport node vmwNsxTDataCenterTransportNodeId
|
|
and master Manager nodes. Also ensure no firewalls are blocking traffic
|
|
between the nodes. Ensure the messaging manager service is running on
|
|
Manager nodes by invoking the command `/etc/init.d/messaging-manager status`.
|
|
If the messaging manager is not running, restart it by
|
|
invoking the command `/etc/init.d/messaging-manager restart`.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 25 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownLongClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Manager Node vmwNsxTDataCenterManagerNodeId
|
|
(vmwNsxTDataCenterApplianceAddress) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 26 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
|
|
(vmwNsxTDataCenterTransportNodeAddress) is down for 5 minutes.
|
|
|
|
Action required:
|
|
Ensure there is network connectivity between the Manager nodes
|
|
and Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress)
|
|
and no firewalls are blocking traffic between the nodes.
|
|
On Windows Transport nodes, ensure the nsx-proxy service is running on the
|
|
Transport node by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 status`
|
|
in the Windows PowerShell. If it is not running, restart it by
|
|
invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 restart`.
|
|
On all other Transport nodes, ensure the nsx-proxy service is running on the
|
|
Transport node by invoking the command `/etc/init.d/nsx-proxy status`.
|
|
If it is not running, restart it by invoking the command
|
|
`/etc/init.d/nsx-proxy restart`.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 1 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
|
|
(vmwNsxTDataCenterTransportNodeAddress) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 2 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownLg NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
|
|
(vmwNsxTDataCenterTransportNodeAddress) is down for 15 minutes.
|
|
|
|
Action required:
|
|
Ensure there is network connectivity between the Manager nodes
|
|
and Transport node vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress)
|
|
and no firewalls are blocking traffic between the nodes.
|
|
On Windows Transport nodes, ensure the nsx-proxy service is running on the
|
|
Transport node by invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 status`
|
|
in the Windows PowerShell. If it is not running, restart it by
|
|
invoking the command `C:\NSX\nsx-proxy\nsx-proxy.ps1 restart`.
|
|
On all other Transport nodes, ensure the nsx-proxy service is running on the
|
|
Transport node by invoking the command `/etc/init.d/nsx-proxy status`.
|
|
If it is not running, restart it by invoking the command
|
|
`/etc/init.d/nsx-proxy restart`.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 5 }
|
|
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownLgClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Management channel to Transport Node vmwNsxTDataCenterTransportNodeName
|
|
(vmwNsxTDataCenterTransportNodeAddress) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 6 }
|
|
|
|
vmwNsxTCommunicationManagerClusterLatencyHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterRemoteManagerNodeId,
|
|
vmwNsxTDataCenterRemoteApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress)
|
|
and vmwNsxTDataCenterRemoteManagerNodeId (vmwNsxTDataCenterRemoteApplianceAddress) is more than 10ms for the last 5 minutes.
|
|
|
|
Action required:
|
|
Ensure there are no firewall rules blocking ping traffic between the Manager nodes.
|
|
If there are other high bandwidth servers and applications sharing the local network,
|
|
consider moving these to a different network.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 17 }
|
|
|
|
vmwNsxTCommunicationManagerClusterLatencyHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterRemoteManagerNodeId,
|
|
vmwNsxTDataCenterRemoteApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average network latency between Manager nodes vmwNsxTDataCenterManagerNodeId (vmwNsxTDataCenterApplianceAddress)
|
|
and vmwNsxTDataCenterRemoteManagerNodeId (vmwNsxTDataCenterRemoteApplianceAddress) is within 10ms.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 18 }
|
|
|
|
vmwNsxTCommunicationManagerControlChannelDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeName,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The communication between the management function and the control
|
|
function has failed on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress).
|
|
|
|
Action required:
|
|
1. On Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress), invoke the
|
|
following NSX CLI command: `get service applianceproxy` to check the status
|
|
of the service periodically for 60 minutes.
|
|
|
|
2. If the service is not running for more than 60 minutes, invoke
|
|
the following NSX CLI command: `restart service applianceproxy` and recheck the
|
|
status. If the service is still down, contact VMware support.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 3 }
|
|
|
|
vmwNsxTCommunicationManagerControlChannelDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeName,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The communication between the management function and the control function
|
|
has been restored on Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterApplianceAddress).
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 4 }
|
|
|
|
vmwNsxTCommunicationManagerFQDNLookupFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceFQDN
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with FQDN
|
|
vmwNsxTDataCenterApplianceFQDN and the publish_fqdns flag was set.
|
|
|
|
Action required:
|
|
1. Assign correct FQDNs to all Manager nodes and verify the DNS
|
|
configuration is correct for successful lookup of all Manager
|
|
nodes' FQDNs.
|
|
2. Alternatively, disable the use of FQDNs by invoking the NSX API
|
|
PUT /api/v1/configs/management with publish_fqdns set to false in the
|
|
request body. After that calls from Transport nodes and from Federation
|
|
to Manager nodes in this cluster will use only IP addresses.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 21 }
|
|
|
|
vmwNsxTCommunicationManagerFQDNLookupFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceFQDN
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FQDN lookup succeeded for Manager node vmwNsxTDataCenterEntityId with FQDN
|
|
vmwNsxTDataCenterApplianceFQDN or the publish_fqdns flag was cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 22 }
|
|
|
|
vmwNsxTCommunicationManagerFQDNReverseLookupFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reverse DNS lookup failed for Manager node vmwNsxTDataCenterEntityId with IP address
|
|
vmwNsxTDataCenterApplianceAddress and the publish_fqdns flag was set.
|
|
|
|
Action required:
|
|
1. Assign correct FQDNs to all Manager nodes and verify the DNS
|
|
configuration is correct for successful reverse lookup of the Manager
|
|
node's IP address.
|
|
2. Alternatively, disable the use of FQDNs by invoking the NSX API
|
|
PUT /api/v1/configs/management with publish_fqdns set to false in the
|
|
request body. After that calls from Transport nodes and from Federation
|
|
to Manager nodes in this cluster will use only IP addresses.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 23 }
|
|
|
|
vmwNsxTCommunicationManagerFQDNReverseLookupFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterApplianceAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reverse DNS lookup succeeded for Manager node vmwNsxTDataCenterEntityId with IP address
|
|
vmwNsxTDataCenterApplianceAddress or the publish_fqdns flag was cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 24 }
|
|
|
|
vmwNsxTCommunicationNetworkLatencyHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average network latency between manager nodes and host
|
|
vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is more than
|
|
150 ms for 5 minutes.
|
|
|
|
Action required:
|
|
1. Wait for 5 minutes to see if the alarm automatically gets resolved.
|
|
2. Ping the NSX Transport node from Manager node. The ping test should not see drops and
|
|
have consistent latency values. VMware recommends latency values of 150ms or less.
|
|
3. Inspect for any other physical network layer issues. If the problem persists, contact
|
|
VMware support.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 29 }
|
|
|
|
vmwNsxTCommunicationNetworkLatencyHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTransportNodeAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The average network latency between manager nodes and host
|
|
vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterTransportNodeAddress) is normal.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 30 }
|
|
|
|
vmwNsxTCommunicationUnreachableCollectorOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVerticalName,
|
|
vmwNsxTDataCenterCollectorIP,
|
|
vmwNsxTDataCenterStackAlias,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can not be reached via existing vmknic(s)(stack vmwNsxTDataCenterStackAlias)
|
|
on any DVS on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
To make the collector reachable for given vertical on the DVS, user has to make sure there
|
|
is(are) vmknic(s) with expected stack vmwNsxTDataCenterStackAlias created and configured with approriate IPv4(6)
|
|
addresses, and the network connection to vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP is also fine. So user has
|
|
to do the checking on DPU vmwNsxTDataCenterDPUId, and perform required configuration to make sure the condition
|
|
is met. Finally if `vmkping vmwNsxTDataCenterCollectorIP -S vmwNsxTDataCenterStackAlias` with SSH to DPU via ESXi enabled succeeds,
|
|
this indicates the problem is gone.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 33 }
|
|
|
|
vmwNsxTCommunicationUnreachableCollectorOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVerticalName,
|
|
vmwNsxTDataCenterCollectorIP,
|
|
vmwNsxTDataCenterStackAlias,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vmwNsxTDataCenterVerticalName collector vmwNsxTDataCenterCollectorIP can be reached with existing vmknic(s)(stack vmwNsxTDataCenterStackAlias)
|
|
now on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTCommunicationFeature 34 }
|
|
|
|
-- **********************************************************
|
|
-- DHCP feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDHCPFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the DHCP feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 20 }
|
|
|
|
vmwNsxTDHCPFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for DHCP feature notifications.
|
|
"
|
|
::= { vmwNsxTDHCPFeaturePrefix 0 }
|
|
|
|
vmwNsxTDHCPPoolLeaseAllocationFailed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDHCPServerId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The addresses in IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId have
|
|
been exhausted. The last DHCP request has failed and future requests will
|
|
fail.
|
|
|
|
Action required:
|
|
Review the DHCP pool configuration in the NSX UI or on the Edge node where
|
|
the DHCP server is running by invoking the NSX CLI command `get dhcp ip-pool`.
|
|
Also review the current active leases on the Edge node by invoking the NSX
|
|
CLI command `get dhcp lease`. Compare the leases to the number of active
|
|
VMs. Consider reducing the lease time on the DHCP server configuration if
|
|
the number of VMs are low compared to the number of active leases. Also
|
|
consider expanding the pool range for the DHCP server by visiting the
|
|
Networking | Segments | Segment page in the NSX UI.
|
|
"
|
|
::= { vmwNsxTDHCPFeature 1 }
|
|
|
|
vmwNsxTDHCPPoolLeaseAllocationFailedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDHCPServerId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP Pool vmwNsxTDataCenterEntityId of DHCP Server vmwNsxTDataCenterDHCPServerId is no longer exhausted.
|
|
A lease is successfully allocated to the last DHCP request.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDHCPFeature 2 }
|
|
|
|
vmwNsxTDHCPPoolOverloaded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDHCPServerId,
|
|
vmwNsxTDataCenterDHCPPoolUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId usage is approaching
|
|
exhaustion with vmwNsxTDataCenterDHCPPoolUsage% IPs allocated.
|
|
|
|
Action required:
|
|
Review the DHCP pool configuration in the NSX UI or on the Edge node where
|
|
the DHCP server is running by invoking the NSX CLI command `get dhcp ip-pool`.
|
|
Also review the current active leases on the Edge node by invoking the NSX
|
|
CLI command `get dhcp lease`. Compare the leases to the number of active
|
|
VMs. Consider reducing the lease time on the DHCP server configuration if
|
|
the number of VMs are low compared to the number of active leases. Also
|
|
consider expanding the pool range for the DHCP server by visiting the
|
|
Networking | Segments | Segment page in the NSX UI.
|
|
"
|
|
::= { vmwNsxTDHCPFeature 3 }
|
|
|
|
vmwNsxTDHCPPoolOverloadedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDHCPServerId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DHCP Server vmwNsxTDataCenterDHCPServerId IP Pool vmwNsxTDataCenterEntityId has fallen below the
|
|
high usage threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDHCPFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- DistributedFirewall feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDistributedFirewallFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the DistributedFirewall feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 31 }
|
|
|
|
vmwNsxTDistributedFirewallFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for DistributedFirewall feature notifications.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeaturePrefix 0 }
|
|
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts. Review
|
|
the security design for optimization. For example, use the apply-to
|
|
configuration if the rules are not applicable to the entire datacenter.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 1 }
|
|
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 2 }
|
|
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts. Review
|
|
the security design for optimization. For example, use the apply-to
|
|
configuration if the rules are not applicable to the entire datacenter.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 17 }
|
|
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW CPU usage on Transport node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 18 }
|
|
|
|
vmwNsxTDistributedFirewallDFWFloodLimitCritical NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterProtocolName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host
|
|
vmwNsxTDataCenterTransportNodeName has reached critical level of 98% of the configured limit for protocol vmwNsxTDataCenterProtocolName.
|
|
|
|
Action required:
|
|
Check VMs on the host in NSX Manager, check configured flood critical level of the
|
|
DFW filter vmwNsxTDataCenterEntityId for protocol vmwNsxTDataCenterProtocolName.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 23 }
|
|
|
|
vmwNsxTDistributedFirewallDFWFloodLimitCriticalClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterProtocolName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The critical flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host
|
|
vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolName is cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 24 }
|
|
|
|
vmwNsxTDistributedFirewallDFWFloodLimitWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterProtocolName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW flood limit for DFW filter vmwNsxTDataCenterEntityId on host
|
|
vmwNsxTDataCenterTransportNodeName has reached warning level of 80% of the configured limit for protocol vmwNsxTDataCenterProtocolName.
|
|
|
|
Action required:
|
|
Check VMs on the host in NSX Manager, check configured flood warning level of the
|
|
DFW filter vmwNsxTDataCenterEntityId for protocol vmwNsxTDataCenterProtocolName.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 21 }
|
|
|
|
vmwNsxTDistributedFirewallDFWFloodLimitWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterProtocolName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The warning flood limit condition for DFW filter vmwNsxTDataCenterEntityId on host
|
|
vmwNsxTDataCenterTransportNodeName for protocol vmwNsxTDataCenterProtocolName is cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 22 }
|
|
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHeapType,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
|
|
is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
View the current DFW memory usage by invoking the NSX CLI command
|
|
`get firewall thresholds` on the host. Consider re-balancing the
|
|
workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 3 }
|
|
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHeapType,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 4 }
|
|
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHeapType,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which
|
|
is at or above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
View the current DFW memory usage by invoking the NSX CLI command
|
|
`get firewall thresholds` on the DPU. Consider re-balancing the
|
|
workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 19 }
|
|
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHeapType,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW Memory usage vmwNsxTDataCenterHeapType on Transport node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% on DPU vmwNsxTDataCenterDPUId which
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 20 }
|
|
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW rules limit for host vmwNsxTDataCenterTransportNodeName is approaching
|
|
the maximum limit.
|
|
|
|
Action required:
|
|
Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI
|
|
command `get firewall rule-stats total` to get the rule statistics
|
|
for rules configured on the ESX host vmwNsxTDataCenterTransportNodeName.
|
|
Reduce the number of rules configured for host vmwNsxTDataCenterTransportNodeName.
|
|
Check the number of rules configured for various VIFs by using NSX CLI
|
|
command `get firewall <VIF_UUID> ruleset rules`.
|
|
Reduce the number of rules configured for various VIFs.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 11 }
|
|
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below the
|
|
threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 12 }
|
|
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW rules limit for host vmwNsxTDataCenterTransportNodeName
|
|
is about to exceed the maximum limit.
|
|
|
|
Action required:
|
|
Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI
|
|
command `get firewall rule-stats total` to get the rule statistics
|
|
for rules configured on the ESX host vmwNsxTDataCenterTransportNodeName.
|
|
Reduce the number of rules configured for host vmwNsxTDataCenterTransportNodeName.
|
|
Check the number of rules configured for various VIFs by using NSX CLI
|
|
command `get firewall <VIF_UUID> ruleset rules`.
|
|
Reduce the number of rules configured for various VIFs.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 13 }
|
|
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW rules limit for host vmwNsxTDataCenterTransportNodeName dropped below maximum
|
|
limit.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 14 }
|
|
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host
|
|
vmwNsxTDataCenterTransportNodeName is approaching the maximum limit.
|
|
|
|
Action required:
|
|
Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI
|
|
command `get firewall <VIF_UUID> ruleset rules` to get the rule
|
|
statistics for rules configured on the corresponding VIF.
|
|
Reduce the number of rules configured for VIF vmwNsxTDataCenterEntityId.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 15 }
|
|
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host
|
|
vmwNsxTDataCenterTransportNodeName dropped below the threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 16 }
|
|
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW rules limit for VIF vmwNsxTDataCenterEntityId on destination host
|
|
vmwNsxTDataCenterTransportNodeName is about to exceed the maximum limit.
|
|
|
|
Action required:
|
|
Log in into the ESX host vmwNsxTDataCenterTransportNodeName and invoke the NSX CLI
|
|
command `get firewall <VIF_UUID> ruleset rules` to get the rule
|
|
statistics for rules configured on the corresponding VIF.
|
|
Reduce the number of rules configured for VIF vmwNsxTDataCenterEntityId.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 9 }
|
|
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW rules limit for VIF vmwNsxTDataCenterEntityId on the destination host
|
|
vmwNsxTDataCenterTransportNodeName dropped below maximum limit.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 10 }
|
|
|
|
vmwNsxTDistributedFirewallDFWSessionCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW session count is high on Transport node vmwNsxTDataCenterEntityId, it has
|
|
reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the network traffic load level of the workloads on the host.
|
|
Consider re-balancing the workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 5 }
|
|
|
|
vmwNsxTDistributedFirewallDFWSessionCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW session count on Transport node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the the threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 6 }
|
|
|
|
vmwNsxTDistributedFirewallDFWVmotionFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW vMotion for DFW filter vmwNsxTDataCenterEntityId on destination host
|
|
vmwNsxTDataCenterTransportNodeName has failed and the port for the entity has been
|
|
disconnected.
|
|
|
|
Action required:
|
|
Check VMs on the host in NSX Manager, manually repush the DFW configuration
|
|
through NSX Manager UI. The DFW policy to be repushed can be traced by the
|
|
DFW filter vmwNsxTDataCenterEntityId. Also consider finding the VM to which the DFW filter
|
|
is attached and restart it.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 7 }
|
|
|
|
vmwNsxTDistributedFirewallDFWVmotionFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DFW configuration for DFW filter vmwNsxTDataCenterEntityId on the destination host
|
|
vmwNsxTDataCenterTransportNodeName has succeeded and error caused by DFW vMotion failure
|
|
cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedFirewallFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- DistributedIDSIPS feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDistributedIDSIPSFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the DistributedIDSIPS feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 33 }
|
|
|
|
vmwNsxTDistributedIDSIPSFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for DistributedIDSIPS feature notifications.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeaturePrefix 0 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IDPS engine has insufficient CPU resources and is unable to keep pace
|
|
with the incoming traffic resulting in the excess traffic being bypassed.
|
|
For more details, login to the ESX host and issue the following command:
|
|
`vsipioctl getdpiinfo -s` and look at oversubscription stats.
|
|
|
|
Action required:
|
|
Review reason for oversubscription. Move certain applications to different
|
|
host.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 53 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distributed IDPS engine has adequate CPU resources and is not bypassing
|
|
any traffic.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 54 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IDPS engine is unable to keep pace with the rate of incoming traffic
|
|
resulting in the excess traffic being bypassed. For more details, login to
|
|
the ESX host and issue the following command: `vsipioctl getdpiinfo -s` and
|
|
look at oversubscription stats.
|
|
|
|
Action required:
|
|
Review reason for oversubscription. Review the IDPS rules to reduce the
|
|
amount of traffic being subject to IDPS service.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 55 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distributed IDPS engine is not bypassing any traffic.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 56 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU utilization for the distributed IDPS engine is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review reason for oversubscription. Move certain applications to different
|
|
host.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 57 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU utilization for the distributed IDPS engine is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 58 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU utilization for the distributed IDPS engine is at or above the very
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review reason for oversubscription. Move certain applications to different
|
|
host.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 59 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CPU utilization for the distributed IDPS engine is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 60 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IDPS engine has insufficient CPU resources and is unable to keep pace
|
|
with the incoming traffic resulting in the excess traffic being dropped.
|
|
For more details, login to the ESX host and issue the following command:
|
|
`vsipioctl getdpiinfo -s` and look at oversubscription stats.
|
|
|
|
Action required:
|
|
Review reason for oversubscription. Move certain applications to different
|
|
host.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 61 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distributed IDPS engine has adequate CPU resources and is not dropping
|
|
any traffic.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 62 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IDPS engine is unable to keep pace with the rate of incoming traffic
|
|
resulting in the excess traffic being dropped. For more details, login to
|
|
the ESX host and issue the following command: `vsipioctl getdpiinfo -s` and
|
|
look at oversubscription stats.
|
|
|
|
Action required:
|
|
Review reason for oversubscription. Review the IDPS rules to reduce the
|
|
amount of traffic being subject to IDPS service.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 63 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distributed IDPS engine is not dropping any traffic.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 64 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network utilization for the distributed IDPS engine is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review reason for oversubscription. Review the IDPS rules to reduce the
|
|
amount of traffic being subject to IDPS service.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 65 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network utilization for the distributed IDPS engine is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 66 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network utilization for the distributed IDPS engine is at or above the very
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review reason for oversubscription. Review the IDPS rules to reduce the
|
|
amount of traffic being subject to IDPS service.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 67 }
|
|
|
|
vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Network utilization for the distributed IDPS engine is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 68 }
|
|
|
|
vmwNsxTDistributedIDSIPSMaxEventsReached NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIDSEventsCount,
|
|
vmwNsxTDataCenterMaxIDSEventsAllowed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount
|
|
which is higher than the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed.
|
|
|
|
Action required:
|
|
There is no manual intervention required. A purge job will kick in automatically
|
|
every 3 minutes and delete 10% of the older records to bring the total intrusion events
|
|
count in the system to below the threshold value of 1.5 million events.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 3 }
|
|
|
|
vmwNsxTDistributedIDSIPSMaxEventsReachedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIDSEventsCount,
|
|
vmwNsxTDataCenterMaxIDSEventsAllowed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of intrusion events in the system is vmwNsxTDataCenterIDSEventsCount
|
|
which is below the maximum allowed value vmwNsxTDataCenterMaxIDSEventsAllowed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 4 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high
|
|
threshold value of 75%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 7 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the high
|
|
threshold value of 75%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 8 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium
|
|
high threshold value of 85%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 21 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the medium high
|
|
threshold value of 85%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 22 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the very
|
|
high threshold value of 95%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 9 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine CPU usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the very
|
|
high threshold value of 95%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 10 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX IDPS is enabled via NSX policy and IDPS rules are configured, but
|
|
NSX-IDPS engine is down.
|
|
|
|
Action required:
|
|
1. Check /var/log/nsx-syslog.log to see if there are errors reported.
|
|
2. Invoke the NSX CLI command `get ids engine status` to check
|
|
if NSX Distributed IDPS is in disabled state. If so,
|
|
invoke `/etc/init.d/nsx-idps start` to start the service.
|
|
3. Invoke `/etc/init.d/nsx-vdpi status` to check if nsx-vdpi is running.
|
|
If not, invoke `/etc/init.d/nsx-vdpi start` to start the service.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 13 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX IDPS is in one of the cases below.
|
|
1. NSX IDPS is disabled via NSX policy.
|
|
2. NSX IDPS engine is enabled, NSX-IDPS engine and vdpi are up, and
|
|
NSX IDPS has been enabled and IDPS rules are configured
|
|
via NSX Policy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 14 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX IDPS is enabled via NSX policy and IDPS rules are configured, but
|
|
NSX-IDPS engine is down on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
1. Check /var/log/nsx-idps/nsx-idps.log and
|
|
/var/log/nsx-syslog.log to see if there are errors reported.
|
|
2. Invoke the NSX CLI command `get ids engine status` to check
|
|
if NSX Distributed IDPS is in disabled state. If so,
|
|
invoke `/etc/init.d/nsx-idps start` to start the service.
|
|
3. Invoke `/etc/init.d/nsx-vdpi status` to check if nsx-vdpi is running.
|
|
If not, invoke `/etc/init.d/nsx-vdpi start` to start the service.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 31 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX IDPS is in one of the cases below on DPU vmwNsxTDataCenterDPUId.
|
|
1. NSX IDPS is disabled via NSX policy.
|
|
2. NSX IDPS engine is enabled, NSX-IDPS engine and vdpi are up, and
|
|
NSX IDPS has been enabled and IDPS rules are configured
|
|
via NSX Policy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 32 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high
|
|
threshold value of 75%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 15 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold
|
|
value of 75%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 16 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the high
|
|
threshold value of 75% on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 23 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the high threshold
|
|
value of 75%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 24 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium
|
|
high threshold value of 85%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 17 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the medium
|
|
high threshold value of 85%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 18 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the medium
|
|
high threshold value of 85% on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 33 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the medium
|
|
high threshold value of 85%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 34 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the
|
|
very high threshold value of 95%.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 19 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the very high
|
|
threshold value of 95%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 20 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is at or above the
|
|
very high threshold value of 95% on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
Consider re-balancing the VM workloads on this host to other hosts.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 35 }
|
|
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX-IDPS engine memory usage has reached on DPU vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterSystemResourceUsage%, which is below the very high
|
|
threshold value of 95%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDistributedIDSIPSFeature 36 }
|
|
|
|
-- **********************************************************
|
|
-- DNS feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDNSFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the DNS feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 30 }
|
|
|
|
vmwNsxTDNSFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for DNS feature notifications.
|
|
"
|
|
::= { vmwNsxTDNSFeaturePrefix 0 }
|
|
|
|
vmwNsxTDNSForwarderDisabled NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterEntityId is disabled.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get dns-forwarders status` to verify
|
|
if the DNS forwarder is in the disabled state.
|
|
2. Use NSX Policy API or Manager API to enable the DNS forwarder it
|
|
should not be in the disabled state.
|
|
"
|
|
::= { vmwNsxTDNSFeature 1 }
|
|
|
|
vmwNsxTDNSForwarderDisabledClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterEntityId is enabled.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDNSFeature 2 }
|
|
|
|
vmwNsxTDNSForwarderDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterEntityId is not running. This is impacting the
|
|
identified DNS Forwarder that is currently enabled.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get dns-forwarders status` to verify
|
|
if the DNS forwarder is in down state.
|
|
2. Check /var/log/syslog to see if there are errors reported.
|
|
3. Collect a support bundle and contact the NSX support team.
|
|
"
|
|
::= { vmwNsxTDNSFeature 3 }
|
|
|
|
vmwNsxTDNSForwarderDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterEntityId is running again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDNSFeature 4 }
|
|
|
|
vmwNsxTDNSForwarderUpstreamServerTimeout NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath,
|
|
vmwNsxTDataCenterDNSId,
|
|
vmwNsxTDataCenterDNSUpstreamIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) did not receive a timely response
|
|
from upstream server vmwNsxTDataCenterDNSUpstreamIP. Compute instance connectivity to
|
|
timed out FQDNs may be impacted.
|
|
|
|
Action required:
|
|
1. Invoke the NSX API GET /api/v1/dns/forwarders/vmwNsxTDataCenterDNSId/nslookup?
|
|
address=<address>&server_ip=vmwNsxTDataCenterDNSUpstreamIP&source_ip=<source_ip>.
|
|
This API request triggers a DNS lookup to the upstream server in the
|
|
DNS forwarder's network namespace. <address> is the IP address or FQDN
|
|
in the same domain as the upstream server. <source_ip> is an IP address
|
|
in the upstream server's zone.
|
|
If the API returns a connection timed out response, there is likely a
|
|
network error or upstream server problem. Check why DSN lookups
|
|
are not reaching the upstream server or why the upstream server is not
|
|
returning a response. If the API response indicates the upstream server
|
|
is answering, proceed to step 2.
|
|
2. Invoke the NSX API GET /api/v1/dns/forwarders/vmwNsxTDataCenterDNSId/nslookup?
|
|
address=<address>.
|
|
This API request triggers a DNS lookup to the DNS forwarder. If the API
|
|
returns a valid response, the upstream server may have recovered and this
|
|
alarm should get resolved within a few minutes. If the API returns a
|
|
connection timed out response, proceed to step 3.
|
|
3. Invoke the NSX CLI command `get dns-forwarder vmwNsxTDataCenterDNSId live-debug
|
|
server-ip vmwNsxTDataCenterDNSUpstreamIP`.
|
|
This command triggers live debugging on the upstream server and logs
|
|
details and statistics showing why the DNS forwarder is not getting a
|
|
response.
|
|
"
|
|
::= { vmwNsxTDNSFeature 5 }
|
|
|
|
vmwNsxTDNSForwarderUpstreamServerTimeoutClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath,
|
|
vmwNsxTDataCenterDNSId,
|
|
vmwNsxTDataCenterDNSUpstreamIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DNS forwarder vmwNsxTDataCenterIntentPath(vmwNsxTDataCenterDNSId) upstream server vmwNsxTDataCenterDNSUpstreamIP
|
|
is normal.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTDNSFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- Edge feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTEdgeFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Edge feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 45 }
|
|
|
|
vmwNsxTEdgeFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Edge feature notifications.
|
|
"
|
|
::= { vmwNsxTEdgeFeaturePrefix 0 }
|
|
|
|
vmwNsxTEdgeEdgeHardwareVersionMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterEdgeClusterName,
|
|
vmwNsxTDataCenterEdgeTNHwVersion,
|
|
vmwNsxTDataCenterEdgeClusterHighestHwVersion
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterTransportNodeName in Edge cluster vmwNsxTDataCenterEdgeClusterName has a hardware version vmwNsxTDataCenterEdgeTNHwVersion,
|
|
which is less than the highest hardware version vmwNsxTDataCenterEdgeClusterHighestHwVersion in the Edge cluster.
|
|
|
|
Action required:
|
|
Follow KB article to resolve hardware version mismatch alarm for Edge node vmwNsxTDataCenterTransportNodeName.
|
|
|
|
For more information see:
|
|
https://www.vmware.com/esx/support/askvmware/index.php?eventtype=edge.edge_hardware_version_mismatch
|
|
"
|
|
::= { vmwNsxTEdgeFeature 15 }
|
|
|
|
vmwNsxTEdgeEdgeHardwareVersionMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterTransportNodeName hardware version mismatch is resolved now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 16 }
|
|
|
|
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterEntityId settings and vSphere configuration are changed and does not
|
|
match the policy intent configuration. The Edge node configuration visible to user
|
|
on UI or API is not same as what is realized. The realized Edge node changes made by
|
|
user outside of NSX Manager are shown in the details of this alarm and any edits in
|
|
UI or API will overwrite the realized configuration. Fields that differ for Edge node
|
|
settings and vSphere configuration are listed in runtime data vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason
|
|
|
|
Action required:
|
|
Review the node settings and vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
|
|
Follow one of following actions to resolve alarm -
|
|
1. Manually update Edge Transport Node setting Policy intent using
|
|
API : PUT https://<manager-ip>/api/v1/transport-nodes/<tn-id>.
|
|
2. Accept intent or vSphere realized Edge node configuration or realized
|
|
Edge node settings for this Edge Transport Node through Edge Transport Node
|
|
resolver to resolve this alarm.
|
|
3. Resolve alarm by accepting the Edge node settings and vSphere realized configuration
|
|
using refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 1 }
|
|
|
|
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId node settings and vSphere settings are consistent with policy intent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 2 }
|
|
|
|
vmwNsxTEdgeEdgeNodeSettingsMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNodeSettingMismatchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterEntityId settings configuration does not match the policy
|
|
intent configuration. The Edge node configuration visible to user on
|
|
UI or API is not same as what is realized. The realized Edge node changes
|
|
made by user outside of NSX Manager are shown in the details of this alarm
|
|
and any edits in UI or API will overwrite the realized configuration.
|
|
Fields that differ for the Edge node are listed in runtime data
|
|
vmwNsxTDataCenterEdgeNodeSettingMismatchReason
|
|
|
|
Action required:
|
|
Review the node settings of this Edge transport node vmwNsxTDataCenterEntityId.
|
|
Follow one of following actions to resolve alarm -
|
|
1. Manually update Edge transport node setting Policy intent
|
|
using API - PUT https://<manager-ip>/api/v1/transport-nodes/<tn-id>.
|
|
2. Accept intent or realized Edge node settings for this Edge transport node
|
|
through Edge transport node resolver to resolve this alarm.
|
|
3. Resolve alarm by accepting the Edge node settings configuration using
|
|
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 3 }
|
|
|
|
vmwNsxTEdgeEdgeNodeSettingsMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId node settings are consistent with policy intent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 4 }
|
|
|
|
vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenter NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPolicyEdgeVMName,
|
|
vmwNsxTDataCenterVMMorefId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId corresponding to the Edge Transport node
|
|
vmwNsxTDataCenterEntityId vSphere placement parameters is not found in both NSX inventory and vCenter.
|
|
The placement parameters in the vSphere configuration of this Edge Transport
|
|
node vmwNsxTDataCenterEntityId refer to the VM with moref vmwNsxTDataCenterVMMorefId.
|
|
|
|
Action required:
|
|
The managed object reference moref id of a VM has the form vm-number, which is
|
|
visible in the URL on selecting the Edge VM in vCenter UI. Example vm-12011 in
|
|
https://<vc-url>/ui/app/vm;nav=h/urn:vmomi:VirtualMachine:vm-12011:164ff798-c4f1-495b-a0be-adfba337e5d2/summary
|
|
Find the VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId in vCenter for this Edge
|
|
Transport Node vmwNsxTDataCenterEntityId.
|
|
Follow the below action to resolve the alarm -
|
|
Check if VM has been deleted in vSphere or is present with a different moref id.
|
|
1. If the VM is still present in vCenter, put the Edge Transport node in
|
|
maintenance mode and then power off and delete the Edge VM in vCenter. Use the NSX
|
|
Redeploy API to deploy a new VM for the Edge node. Data traffic for the Edge Transport
|
|
node will be disrupted in the interim duration if the Edge VM is forwarding traffic.
|
|
2. If the VM is not present in vCenter, use the redeploy API to deploy a new VM for the Edge node.
|
|
POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=redeploy.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 11 }
|
|
|
|
vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenterClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVMMorefId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId with VM moref id vmwNsxTDataCenterVMMorefId is present in both NSX inventory and vCenter.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 12 }
|
|
|
|
vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenter NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPolicyEdgeVMName,
|
|
vmwNsxTDataCenterVMMorefId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId corresponding to the Edge Transport node
|
|
vmwNsxTDataCenterEntityId vSphere placement parameters is found in NSX inventory but is not present in vCenter.
|
|
Check if the VM has been removed in vCenter or is present with
|
|
a different VM moref id.
|
|
|
|
Action required:
|
|
The managed object reference moref id of a VM has the form vm-number, which is
|
|
visible in the URL on selecting the Edge VM in vCenter UI. Example vm-12011 in
|
|
https://<vc-url>/ui/app/vm;nav=h/urn:vmomi:VirtualMachine:vm-12011:164ff798-c4f1-495b-a0be-adfba337e5d2/summary
|
|
Find the VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId in vCenter for this Edge
|
|
Transport Node vmwNsxTDataCenterEntityId.
|
|
If the Edge VM is present in vCenter with a different moref id, follow the below action.
|
|
Use NSX add or update placement API with JSON request payload properties vm_id and vm_deployment_config
|
|
to update the new vm moref id and vSphere deployment parameters.
|
|
POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=addOrUpdatePlacementReferences.
|
|
If the Edge VM with name vmwNsxTDataCenterPolicyEdgeVMName is not present in vCenter, use the NSX Redeploy API
|
|
to deploy a new VM for the Edge node.
|
|
POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=redeploy.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 9 }
|
|
|
|
vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenterClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVMMorefId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId with VM moref id vmwNsxTDataCenterVMMorefId is present in both NSX inventory and vCenter.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 10 }
|
|
|
|
vmwNsxTEdgeEdgeVmvSphereSettingsMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterEntityId configuration on vSphere does not match the policy
|
|
intent configuration. The Edge node configuration visible to user on UI or API
|
|
is not same as what is realized. The realized Edge node changes made by user
|
|
outside of NSX Manager are shown in the details of this alarm and any edits
|
|
in UI or API will overwrite the realized configuration. Fields that differ for
|
|
the Edge node are listed in runtime data vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason
|
|
|
|
Action required:
|
|
Review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
|
|
Follow one of following actions to resolve alarm -
|
|
1. Accept intent or vSphere realized Edge node configuration for this Edge Transport Node
|
|
through Edge Transport Node resolver to resolve this alarm.
|
|
2. Resolve alarm by accepting the Edge node vSphere realized configuration using
|
|
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 5 }
|
|
|
|
vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId VM vSphere settings are consistent with policy intent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 6 }
|
|
|
|
vmwNsxTEdgeEdgevSphereLocationMismatch NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgevSphereLocationMismatchReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Edge node vmwNsxTDataCenterEntityId has been moved using vMotion. The Edge node vmwNsxTDataCenterEntityId, the configuration
|
|
on vSphere does not match the policy intent configuration. The Edge node configuration visible to
|
|
user on UI or API is not same as what is realized. The realized Edge node changes made by user outside
|
|
of NSX Manager are shown in the details of this alarm. Fields that differ for the Edge node are listed
|
|
in runtime data vmwNsxTDataCenterEdgevSphereLocationMismatchReason
|
|
|
|
Action required:
|
|
Review the vSphere configuration of this Edge Transport Node vmwNsxTDataCenterEntityId.
|
|
Follow one of following actions to resolve alarm -
|
|
1. Resolve alarm by accepting the Edge node vSphere realized config using
|
|
refresh API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=refresh_node_configuration&resource_type=EdgeNode.
|
|
2. If you want to return to the previous location use
|
|
NSX Redeploy API - POST https://<manager-ip>/api/v1/transport-nodes/<tn-id>?action=redeploy.
|
|
vMotion back to the original host is not supported.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 7 }
|
|
|
|
vmwNsxTEdgeEdgevSphereLocationMismatchClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId node vSphere settings are consistent with policy intent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 8 }
|
|
|
|
vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeploy NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVMMorefId,
|
|
vmwNsxTDataCenterNewVMMorefId,
|
|
vmwNsxTDataCenterPolicyEdgeVMName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Failed to power off and delete the Edge node vmwNsxTDataCenterEntityId VM with moref id vmwNsxTDataCenterVMMorefId
|
|
in vCenter during Redeploy operation. A new Edge VM with moref id vmwNsxTDataCenterNewVMMorefId has
|
|
been deployed. Both old and new VMs for this Edge are functional at the same time and
|
|
may result in IP conflicts and networking issues.
|
|
|
|
Action required:
|
|
The managed object reference moref id of a VM has the form vm-number, which is
|
|
visible in the URL on selecting the Edge VM in vCenter UI. Example vm-12011 in
|
|
https://<vc-url>/ui/app/vm;nav=h/urn:vmomi:VirtualMachine:vm-12011:164ff798-c4f1-495b-a0be-adfba337e5d2/summary
|
|
Find the VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId in vCenter for this Edge
|
|
Transport Node vmwNsxTDataCenterEntityId.
|
|
Power off and delete the old Edge VM vmwNsxTDataCenterPolicyEdgeVMName with moref id vmwNsxTDataCenterVMMorefId in vCenter.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 13 }
|
|
|
|
vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeployClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVMMorefId,
|
|
vmwNsxTDataCenterNewVMMorefId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterEntityId with stale VM moref id vmwNsxTDataCenterVMMorefId is not found
|
|
anymore in both NSX inventory and vCenter. New deployed VM with moref id vmwNsxTDataCenterNewVMMorefId
|
|
is present in both NSX inventory and vCenter.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeFeature 14 }
|
|
|
|
-- **********************************************************
|
|
-- EdgeCluster feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTEdgeClusterFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the EdgeCluster feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 49 }
|
|
|
|
vmwNsxTEdgeClusterFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for EdgeCluster feature notifications.
|
|
"
|
|
::= { vmwNsxTEdgeClusterFeaturePrefix 0 }
|
|
|
|
vmwNsxTEdgeClusterEdgeClusterMemberRelocateFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeClusterId,
|
|
vmwNsxTDataCenterMemberIndexId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The operation on Edge cluster vmwNsxTDataCenterEdgeClusterId to relocate all service
|
|
context failed for Edge cluster member index vmwNsxTDataCenterMemberIndexId with
|
|
Transport node ID vmwNsxTDataCenterTransportNodeId
|
|
|
|
Action required:
|
|
Review the available capacity for the Edge cluster. If more capacity
|
|
is required, scale your Edge cluster. Retry the relocate Edge cluster
|
|
member operation.
|
|
"
|
|
::= { vmwNsxTEdgeClusterFeature 5 }
|
|
|
|
vmwNsxTEdgeClusterEdgeClusterMemberRelocateFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node with vmwNsxTDataCenterTransportNodeId relocation failure has been resolved now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeClusterFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- EdgeHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTEdgeHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the EdgeHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 2 }
|
|
|
|
vmwNsxTEdgeHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for EdgeHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTEdgeHealthDatapathThreadDeadlocked NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeThreadName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node datapath thread vmwNsxTDataCenterEdgeThreadName is deadlocked.
|
|
|
|
Action required:
|
|
Restart the dataplane service by invoking the NSX CLI command `restart service dataplane`.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 45 }
|
|
|
|
vmwNsxTEdgeHealthDatapathThreadDeadlockedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeThreadName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node datapath thread vmwNsxTDataCenterEdgeThreadName is free from deadlock.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 46 }
|
|
|
|
vmwNsxTEdgeHealthEdgeCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the configuration, running services and sizing of this Edge
|
|
node. Consider adjusting the Edge appliance form factor size or rebalancing
|
|
services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 1 }
|
|
|
|
vmwNsxTEdgeHealthEdgeCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 2 }
|
|
|
|
vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the configuration, running services and sizing of this Edge
|
|
node. Consider adjusting the Edge appliance form factor size or rebalancing
|
|
services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 3 }
|
|
|
|
vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 4 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Failed to enable the datapath on the Edge node after three attempts.
|
|
|
|
Action required:
|
|
Ensure the Edge node's connectivity to the Manager node is healthy. From
|
|
the Edge node's NSX CLI, invoke the command `get services` to check the
|
|
health of services. If the dataplane service is stopped, invoke the
|
|
command `start service dataplane` to start it.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 21 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Datapath on the Edge node has been successfully enabled.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 22 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDatapathResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterDatapathResourceUsage% which is at or above the high
|
|
threshold for at least two minutes.
|
|
|
|
Action required:
|
|
Review the CPU statistics on the Edge node by invoking the NSX CLI command
|
|
`get dataplane cpu stats` to show packet rates per CPU core. Higher CPU
|
|
usage is expected with higher packet rates. Consider increasing the Edge
|
|
appliance form factor size and rebalancing services on this Edge node to
|
|
other Edge nodes in the same cluster or other Edge clusters.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 17 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the
|
|
high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 18 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDatapathResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath CPU usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterDatapathResourceUsage% which is at or above the very high
|
|
threshold for at least two minutes.
|
|
|
|
Action required:
|
|
Review the CPU statistics on the Edge node by invoking the NSX CLI command
|
|
`get dataplane cpu stats` to show packet rates per CPU core. Higher CPU
|
|
usage is expected with higher packet rates. Consider increasing the Edge
|
|
appliance form factor size and rebalancing services on this Edge node to
|
|
other Edge nodes in the same cluster or other Edge clusters.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 19 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Edge node vmwNsxTDataCenterEntityId has reached below the
|
|
very high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 20 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeCryptoDrvName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is down.
|
|
|
|
Action required:
|
|
Upgrade the Edge node as needed.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 23 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeCryptoDrvName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node crypto driver vmwNsxTDataCenterEdgeCryptoDrvName is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 24 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathMempoolHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMempoolName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
|
|
is at or above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Log in as the root user and invoke the command
|
|
`edge-appctl -t /var/run/vmware/edge/dpd.ctl mempool/show` and
|
|
`edge-appctl -t /var/run/vmware/edge/dpd.ctl memory/show malloc_heap` to
|
|
check DPDK memory usage.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 25 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMempoolName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath mempool usage for vmwNsxTDataCenterMempoolName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterSystemResourceUsage% which
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 26 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or above
|
|
the high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
|
|
|
|
Action required:
|
|
Examine the traffic thoughput levels on the NIC and determine whether
|
|
configuration changes are needed. The 'get dataplane thoughput <seconds>'
|
|
command can be used to monitor throughput.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 49 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which
|
|
is below the high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 50 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which is at or above
|
|
the very high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
|
|
|
|
Action required:
|
|
Examine the traffic thoughput levels on the NIC and determine whether
|
|
configuration changes are needed. The 'get dataplane thoughput <seconds>'
|
|
command can be used to monitor throughput.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 51 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The datapath NIC throughput for vmwNsxTDataCenterEdgeNICName on Edge node
|
|
vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterNICThroughput% which
|
|
is below the very high threshold value of vmwNsxTDataCenterNICThroughputThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 52 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine the partition with high usage and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 9 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 10 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine the partition with high usage and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 11 }
|
|
|
|
vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Edge node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the
|
|
very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 12 }
|
|
|
|
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDatapathResourceUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global ARP table usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterDatapathResourceUsage% which is above the high threshold
|
|
for over two minutes.
|
|
|
|
Action required:
|
|
Log in as the root user and invoke the command
|
|
`edge-appctl -t /var/run/vmware/edge/dpd.ctl neigh/show` and check
|
|
if neigh cache usage is normal. If it is normal, invoke the command
|
|
`edge-appctl -t /var/run/vmware/edge/dpd.ctl neigh/set_param max_entries`
|
|
to increase the ARP table size.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 27 }
|
|
|
|
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global ARP table usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 28 }
|
|
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the configuration, running services and sizing of this Edge
|
|
node. Consider adjusting the Edge appliance form factor size or rebalancing
|
|
services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 5 }
|
|
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 6 }
|
|
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the configuration, running services and sizing of this Edge
|
|
node. Consider adjusting the Edge appliance form factor size or rebalancing
|
|
services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 7 }
|
|
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Edge node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 8 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICLinkStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node NIC vmwNsxTDataCenterEdgeNICName link is down.
|
|
|
|
Action required:
|
|
On the Edge node confirm if the NIC link is physically down by invoking
|
|
the NSX CLI command `get interfaces`. If it is down, verify the cable
|
|
connection.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 29 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node NIC vmwNsxTDataCenterEdgeNICName link is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 30 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterRxRingBufferOverflowPercentage,
|
|
vmwNsxTDataCenterRxMisses,
|
|
vmwNsxTDataCenterRxProcessed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer has overflowed by
|
|
vmwNsxTDataCenterRxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEntityId.
|
|
The missed packet count is vmwNsxTDataCenterRxMisses and processed packet count
|
|
is vmwNsxTDataCenterRxProcessed.
|
|
|
|
Action required:
|
|
Run the NSX CLI command `get dataplane cpu stats` on the edge node and check:
|
|
1. If cpu usage is high, i.e., > 90%, then take a packet capture on
|
|
the interface using the command `start capture interface
|
|
<interface-name> direction input` or `start capture interface
|
|
<interface-name> direction input core <core-id>` (to capture
|
|
packets ingressing on specific core whose usage is high).
|
|
Then analyze the capture to see if there are majority of
|
|
fragmented packets or ipsec packets. If yes, then it is expected
|
|
behavior. If not, datapath is probably busy with other operations.
|
|
If this alarm lasts more than 2-3 minutes, contact VMware Support.
|
|
2. If cpu usage is not high, i.e., < 90%, then check if rx pps is high
|
|
using the command `get dataplane cpu stats` (just to make sure the
|
|
traffic rate is increasing). Then increase the ring size by 1024
|
|
using the command `set dataplane ring-size rx <ring-size>`.
|
|
NOTE - The continuous increase of ring size by 1024 factor can lead
|
|
to some performance issues.
|
|
If even after increasing the ring size, the issue persists then
|
|
it is an indication that edge needs a larger form factor deployment
|
|
to accommodate the traffic.
|
|
3. If the alarm keeps on flapping i.e., triggers and resolves very soon,
|
|
then it is due to bursty traffic. In this case check if rx pps as
|
|
described above, if it is not high during the alarm active period
|
|
then contact VMware Support. If pps is high it confirms bursty traffic.
|
|
Consider suppressing the alarm.
|
|
NOTE - There is no specific benchmark to decide what is regarded as a
|
|
high pps value. It depends on infrastructure and type of traffic.
|
|
The comparison can be made by noting down when alarm is inactive and
|
|
when it is active.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 31 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge NIC vmwNsxTDataCenterEdgeNICName receive ring buffer usage on Edge node
|
|
vmwNsxTDataCenterEntityId is no longer overflowing.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 32 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterTxRingBufferOverflowPercentage,
|
|
vmwNsxTDataCenterTxMisses,
|
|
vmwNsxTDataCenterTxProcessed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer has overflowed by
|
|
vmwNsxTDataCenterTxRingBufferOverflowPercentage% on Edge node vmwNsxTDataCenterEntityId.
|
|
The missed packet count is vmwNsxTDataCenterTxMisses and processed packet count
|
|
is vmwNsxTDataCenterTxProcessed.
|
|
|
|
Action required:
|
|
1. If a lot of VMs are accommodated along with edge by the hypervisor
|
|
then edge VM might not get time to run, hence the packets might
|
|
not be retrieved by hypervisor. Then probably migrating the edge VM
|
|
to a host with fewer VMs.
|
|
2. Increase the ring size by 1024 using the command `set dataplane
|
|
ring-size tx <ring-size>`. If even after increasing the ring size,
|
|
the issue persists then contact VMware Support as the ESX side
|
|
transmit ring buffer might be of lower value. If there is no
|
|
issue on ESX side, it indicates the edge needs to be scaled to
|
|
a larger form factor deployment to accommodate the traffic.
|
|
3. If the alarm keeps on flapping, i.e., triggers and resolves very soon,
|
|
then it is due to bursty traffic. In this case check if tx pps using
|
|
the command `get dataplane cpu stats`. If it is not high during the
|
|
alarm active period then contact VMware Support.
|
|
If pps is high it confirms bursty traffic. Consider suppressing the
|
|
alarm.
|
|
NOTE - There is no specific benchmark to decide what is regarded as a
|
|
high pps value. It depends on infrastructure and type of traffic.
|
|
The comparison can be made by noting down when alarm is inactive and
|
|
when it is active.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 33 }
|
|
|
|
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeNICName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge NIC vmwNsxTDataCenterEdgeNICName transmit ring buffer usage on Edge node
|
|
vmwNsxTDataCenterEntityId is no longer overflowing.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 34 }
|
|
|
|
vmwNsxTEdgeHealthFailureDomainDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All members of failure domain vmwNsxTDataCenterTransportNodeId are down.
|
|
|
|
Action required:
|
|
1. On the Edge node identified by vmwNsxTDataCenterTransportNodeId, check the connectivity
|
|
to the management and control planes by invoking the NSX CLI command
|
|
`get managers` and `get controllers`.
|
|
2. Invoke the NSX CLI command `get interface eth0` to check the management
|
|
interface status.
|
|
3. Invoke the CLI `get services` to check the core services status like
|
|
dataplane/local-controller/nestdb/router, etc.
|
|
4. Inspect the /var/log/syslog to find the suspecting error.
|
|
5. Reboot the Edge node.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 53 }
|
|
|
|
vmwNsxTEdgeHealthFailureDomainDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All members of failure domain vmwNsxTDataCenterTransportNodeId are reachable.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 54 }
|
|
|
|
vmwNsxTEdgeHealthMegaFlowCacheHitRateLow NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFlowCacheThreshold,
|
|
vmwNsxTDataCenterCoreId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mega Flow Cache hit rate on Edge node vmwNsxTDataCenterEntityId has decreased below the
|
|
specified threshold of vmwNsxTDataCenterFlowCacheThreshold% for core vmwNsxTDataCenterCoreId, and
|
|
the Datapath CPU usage has increased for the last 30 minutes.
|
|
|
|
Action required:
|
|
The Cache Flow hit rate has decreased for the last 30 minutes which is an
|
|
indication that there may be degradation on Edge performance. The traffic will
|
|
continue to be forwarded and you may not experience any issues.
|
|
Check the datapath CPU utilization for Edge vmwNsxTDataCenterEntityId core vmwNsxTDataCenterCoreId if it is
|
|
high for the last 30 minutes. The Edge will have low flow-cache hit rate when there
|
|
are continuously new flows getting created because the first packet of any new flow
|
|
will be used to setup to flow-cache for fast path processing.
|
|
You may want to increase your Edge appliance size or
|
|
increase the number of Edge nodes used for Active/Active Gateways.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 55 }
|
|
|
|
vmwNsxTEdgeHealthMegaFlowCacheHitRateLowClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flow Cache hit rate is in the normal range.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 56 }
|
|
|
|
vmwNsxTEdgeHealthMicroFlowCacheHitRateLow NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFlowCacheThreshold,
|
|
vmwNsxTDataCenterCoreId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Micro Flow Cache hit rate on Edge node vmwNsxTDataCenterEntityId has decreased below the
|
|
specified threshold of vmwNsxTDataCenterFlowCacheThreshold% for core vmwNsxTDataCenterCoreId, and
|
|
the Datapath CPU usage has increased for the last 30 minutes.
|
|
|
|
Action required:
|
|
The Cache Flow hit rate has decreased for the last 30 minutes which is an
|
|
indication that there may be degradation on Edge performance. The traffic will
|
|
continue to be forwarded and you may not experience any issues.
|
|
Check the datapath CPU utilization for Edge vmwNsxTDataCenterEntityId core vmwNsxTDataCenterCoreId if it is
|
|
high for the last 30 minutes. The Edge will have low flow-cache hit rate when there
|
|
are continuously new flows getting created because the first packet of any new flow
|
|
will be used to setup to flow-cache for fast path processing.
|
|
You may want to increase your Edge appliance size or
|
|
increase the number of Edge nodes used for Active/Active Gateways.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 57 }
|
|
|
|
vmwNsxTEdgeHealthMicroFlowCacheHitRateLowClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flow Cache hit rate is in the normal range.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 58 }
|
|
|
|
vmwNsxTEdgeHealthStorageError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The following disk partitions on the Edge node are in
|
|
read-only mode: vmwNsxTDataCenterDiskPartitionName
|
|
|
|
Action required:
|
|
Examine the read-only partition to see if reboot resolves the issue
|
|
or the disk needs to be replaced. Contact GSS for more information.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 37 }
|
|
|
|
vmwNsxTEdgeHealthStorageErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The following disk partitions on the Edge node have recovered from
|
|
read-only mode: vmwNsxTDataCenterDiskPartitionName
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEdgeHealthFeature 38 }
|
|
|
|
-- **********************************************************
|
|
-- EndpointProtection feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTEndpointProtectionFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the EndpointProtection feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 13 }
|
|
|
|
vmwNsxTEndpointProtectionFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for EndpointProtection feature notifications.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeaturePrefix 0 }
|
|
|
|
vmwNsxTEndpointProtectionEAMStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Start the ESX Agent Manager (EAM) service. SSH into vCenter and invoke
|
|
the command `service vmware-eam start`.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeature 1 }
|
|
|
|
vmwNsxTEndpointProtectionEAMStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ESX Agent Manager (EAM) service on compute manager vmwNsxTDataCenterEntityId is either up
|
|
or compute manager vmwNsxTDataCenterEntityId has been removed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeature 2 }
|
|
|
|
vmwNsxTEndpointProtectionPartnerChannelDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connection between host module and Partner SVM vmwNsxTDataCenterEntityId
|
|
is down.
|
|
|
|
Action required:
|
|
Refer to https://kb.vmware.com/s/article/85844 and make sure
|
|
that Partner SVM vmwNsxTDataCenterEntityId is re-connected to the host module.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeature 3 }
|
|
|
|
vmwNsxTEndpointProtectionPartnerChannelDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connection between host module and Partner SVM vmwNsxTDataCenterEntityId
|
|
is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTEndpointProtectionFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- Federation feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTFederationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Federation feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 32 }
|
|
|
|
vmwNsxTFederationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Federation feature notifications.
|
|
"
|
|
::= { vmwNsxTFederationFeaturePrefix 0 }
|
|
|
|
vmwNsxTFederationGMToGMLatencyWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Latency is higher than expected between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath.
|
|
|
|
Action required:
|
|
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
|
|
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable, check for flakiness in WAN connectivity.
|
|
"
|
|
::= { vmwNsxTFederationFeature 17 }
|
|
|
|
vmwNsxTFederationGMToGMLatencyWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Latency is below expected levels between Global Managers vmwNsxTDataCenterFromGMPath and vmwNsxTDataCenterToGMPath.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 18 }
|
|
|
|
vmwNsxTFederationGMToGMSplitBrain NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterActiveGlobalManagers
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Multiple Global Manager nodes are active: vmwNsxTDataCenterActiveGlobalManagers. Only one Global Manager node must be active
|
|
at any time.
|
|
|
|
Action required:
|
|
Configure only one Global Manager node as active and all other Global Manager nodes as standby.
|
|
"
|
|
::= { vmwNsxTFederationFeature 9 }
|
|
|
|
vmwNsxTFederationGMToGMSplitBrainClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterActiveGlobalManager
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Global Manager node vmwNsxTDataCenterActiveGlobalManager is the only active Global Manager node now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 10 }
|
|
|
|
vmwNsxTFederationGMToGMSynchronizationError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath cannot
|
|
synchronize for more than 5 minutes.
|
|
|
|
Action required:
|
|
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
|
|
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping.
|
|
"
|
|
::= { vmwNsxTFederationFeature 19 }
|
|
|
|
vmwNsxTFederationGMToGMSynchronizationErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 20 }
|
|
|
|
vmwNsxTFederationGMToGMSynchronizationWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active Global Manager vmwNsxTDataCenterFromGMPath to Standby Global Manager vmwNsxTDataCenterToGMPath can not synchronize.
|
|
|
|
Action required:
|
|
Check the connectivity from Global Manager vmwNsxTDataCenterFromGMPath(vmwNsxTDataCenterSiteId) to the Global Manager
|
|
vmwNsxTDataCenterToGMPath(vmwNsxTDataCenterRemoteSiteId) via ping.
|
|
"
|
|
::= { vmwNsxTFederationFeature 21 }
|
|
|
|
vmwNsxTFederationGMToGMSynchronizationWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterToGMPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Synchronization from active Global Manager vmwNsxTDataCenterFromGMPath to standby vmwNsxTDataCenterToGMPath is healthy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 22 }
|
|
|
|
vmwNsxTFederationGMToLMLatencyWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterLatencyValue,
|
|
vmwNsxTDataCenterLatencyThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Latency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached
|
|
vmwNsxTDataCenterLatencyValue which is above the threshold value of vmwNsxTDataCenterLatencyThreshold.
|
|
|
|
Action required:
|
|
1. Check the network connectivity between remote site and local site via ping.
|
|
2. Ensure port TCP/1236 traffic is allowed between the local and remote sites.
|
|
3. Check /var/log/async-replicator/ar.log to see if there are errors reported.
|
|
"
|
|
::= { vmwNsxTFederationFeature 27 }
|
|
|
|
vmwNsxTFederationGMToLMLatencyWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterLatencyValue,
|
|
vmwNsxTDataCenterLatencyThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Latency between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) has reached
|
|
vmwNsxTDataCenterLatencyValue which below the threshold value of vmwNsxTDataCenterLatencyThreshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 28 }
|
|
|
|
vmwNsxTFederationGMToLMSynchronizationError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterFlowIdentifier,
|
|
vmwNsxTDataCenterSyncIssueReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
|
|
failed for the vmwNsxTDataCenterFlowIdentifier for an extended period. Reason: vmwNsxTDataCenterSyncIssueReason.
|
|
|
|
Action required:
|
|
1. Check the network connectivity between remote site and local site via ping.
|
|
2. Ensure port TCP/1236 traffic is allowed between the local and remote sites.
|
|
3. Ensure the async-replicator service is running on both local and remote sites.
|
|
Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the
|
|
`get service async_replicator` NSX CLI command to determine if the service is running.
|
|
If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or
|
|
the `restart service async_replicator` NSX CLI to restart the service.
|
|
4. Check /var/log/async-replicator/ar.log to see if there are errors reported.
|
|
5. Collect a support bundle and contact the NSX support team.
|
|
"
|
|
::= { vmwNsxTFederationFeature 23 }
|
|
|
|
vmwNsxTFederationGMToLMSynchronizationErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterFlowIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDataCenterFlowIdentifier.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 24 }
|
|
|
|
vmwNsxTFederationGMToLMSynchronizationWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterFlowIdentifier,
|
|
vmwNsxTDataCenterSyncIssueReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data synchronization between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for the
|
|
vmwNsxTDataCenterFlowIdentifier. Reason: vmwNsxTDataCenterSyncIssueReason
|
|
|
|
Action required:
|
|
1. Check the network connectivity between remote site and local site via ping.
|
|
2. Ensure port TCP/1236 traffic is allowed between the local and remote sites.
|
|
3. Ensure the async-replicator service is running on both local and remote sites.
|
|
Invoke the GET /api/v1/node/services/async_replicator/status NSX API or the
|
|
`get service async_replicator` NSX CLI command to determine if the service is running.
|
|
If not running, invoke the POST /api/v1/node/services/async_replicator?action=restart NSX API or
|
|
the `restart service async_replicator` NSX CLI to restart the service.
|
|
4. Check /var/log/async-replicator/ar.log to see if there are errors reported.
|
|
"
|
|
::= { vmwNsxTFederationFeature 25 }
|
|
|
|
vmwNsxTFederationGMToLMSynchronizationWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterFlowIdentifier
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized for vmwNsxTDataCenterFlowIdentifier.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 26 }
|
|
|
|
vmwNsxTFederationLMRestoreWhileConfigImportInProgress NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Config import from site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is in progress. However site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is restored
|
|
from backup by the administrator leaving it in an inconsistent state.
|
|
|
|
Action required:
|
|
1. Log in to NSX Global Manager appliance CLI.
|
|
2. Switch to root.
|
|
3. Invoke the NSX API DELETE http://localhost:64440/gm/api/v1/infra/sites/<site-name>/onboarding/status in local mode,
|
|
this will delete site on-boarding status for Global Manager.
|
|
4. Re-initiate config on-boarding again.
|
|
"
|
|
::= { vmwNsxTFederationFeature 31 }
|
|
|
|
vmwNsxTFederationLMRestoreWhileConfigImportInProgressClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Config inconsistency at site vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) is resolved.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 32 }
|
|
|
|
vmwNsxTFederationLmToLmSynchronizationError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
|
|
failed for more than 15 minutes.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection
|
|
state between the remote locations. If a remote location is connected but not synchronized,
|
|
it is possible that the location is still in the process of master resolution. In
|
|
this case, wait for around 10 seconds and try invoking the CLI again to
|
|
check for the state of the remote location. If a location is disconnected, try the next
|
|
step.
|
|
2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs
|
|
in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable,
|
|
check for flakiness in WAN connectivity. If there are no physical network
|
|
connectivity issues, try the next step.
|
|
3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in
|
|
location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site
|
|
communication errors. In addition, also look for errors being logged by the
|
|
nsx-appl-proxy subcomponent within /var/log/syslog.
|
|
"
|
|
::= { vmwNsxTFederationFeature 3 }
|
|
|
|
vmwNsxTFederationLmToLmSynchronizationErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 4 }
|
|
|
|
vmwNsxTFederationLmToLmSynchronizationWarning NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The synchronization between vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) failed for more than 3 minutes.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get site-replicator remote-sites` to get connection
|
|
state between the remote locations. If a remote location is connected but not synchronized,
|
|
it is possible that the location is still in the process of master resolution. In
|
|
this case, wait for around 10 seconds and try invoking the CLI again to
|
|
check for the state of the remote location. If a location is disconnected, try the next
|
|
step.
|
|
2. Check the connectivity from Local Manager (LM) in location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) to the LMs
|
|
in location vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) via ping. If they are not pingable,
|
|
check for flakiness in WAN connectivity. If there are no physical network
|
|
connectivity issues, try the next step.
|
|
3. Check the /var/log/cloudnet/nsx-ccp.log file on the Manager nodes in the local cluster in
|
|
location vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) that triggered the alarm to see if there are any cross-site
|
|
communication errors. In addition, also look for errors being logged by the
|
|
nsx-appl-proxy subcomponent within /var/log/syslog.
|
|
"
|
|
::= { vmwNsxTFederationFeature 5 }
|
|
|
|
vmwNsxTFederationLmToLmSynchronizationWarningClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote locations vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId) are now synchronized.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 6 }
|
|
|
|
vmwNsxTFederationQueueOccupancyThresholdExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterQueueName,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterQueueSize,
|
|
vmwNsxTDataCenterQueueSizeThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
|
|
has reached size vmwNsxTDataCenterQueueSize which is at or above the maximum threshold of vmwNsxTDataCenterQueueSizeThreshold%.
|
|
|
|
Action required:
|
|
Queue size can exceed threshold due to communication issue with remote site or an overloaded system.
|
|
Check system performance and /var/log/async-replicator/ar.log to see if there are any errors reported.
|
|
"
|
|
::= { vmwNsxTFederationFeature 29 }
|
|
|
|
vmwNsxTFederationQueueOccupancyThresholdExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterQueueName,
|
|
vmwNsxTDataCenterSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterQueueSize,
|
|
vmwNsxTDataCenterQueueSizeThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Queue (vmwNsxTDataCenterQueueName) used for syncing data between sites vmwNsxTDataCenterSiteName(vmwNsxTDataCenterSiteId) and vmwNsxTDataCenterRemoteSiteName(vmwNsxTDataCenterRemoteSiteId)
|
|
has reached size vmwNsxTDataCenterQueueSize which is below the maximum threshold of vmwNsxTDataCenterQueueSizeThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 30 }
|
|
|
|
vmwNsxTFederationRtepBGPDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterBGPSourceIP,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP
|
|
to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP is down.
|
|
Reason: vmwNsxTDataCenterFailureReason.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers` on the affected edge node.
|
|
2. Switch to REMOTE_TUNNEL_VRF context.
|
|
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status.
|
|
4. Alternatively, invoke the NSX API GET /api/v1/transport-nodes/<transport-node-id>/inter-site/bgp/summary
|
|
to get the BGP neighbor status.
|
|
5. Invoke the NSX CLI command `get interfaces` and check if the correct RTEP IP address is assigned
|
|
to the interface with name remote-tunnel-endpoint.
|
|
6. Check if the ping is working successfully between assigned RTEP IP address (vmwNsxTDataCenterBGPSourceIP) and the
|
|
remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP.
|
|
7. Check /var/log/syslog for any errors related to BGP.
|
|
8. Invoke the NSX API GET or PUT /api/v1/transport-nodes/<transport-node-id> to get/update remote_tunnel_endpoint
|
|
configuration on the edge node.
|
|
This will update the RTEP IP assigned to the affected edge node.
|
|
|
|
If the reason indicates `Edge is not ready`, check why the Edge node is not in good state.
|
|
1. Invoke the NSX CLI command `get edge-cluster status` to check reason why Edge node might be down.
|
|
2. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
|
|
3. Check any Edge health related alarms to get more information.
|
|
"
|
|
::= { vmwNsxTFederationFeature 1 }
|
|
|
|
vmwNsxTFederationRtepBGPDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterBGPSourceIP,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterBGPNeighborIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RTEP (Remote Tunnel Endpoint) BGP session from source IP vmwNsxTDataCenterBGPSourceIP
|
|
to remote location vmwNsxTDataCenterRemoteSiteName neighbor IP vmwNsxTDataCenterBGPNeighborIP is established.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 2 }
|
|
|
|
vmwNsxTFederationRtepConnectivityLost NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterRemoteSiteName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterTransportNodeName lost RTEP (Remote Tunnel Endpoint) connectivity
|
|
with remote location vmwNsxTDataCenterRemoteSiteName.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers` on the affected edge node vmwNsxTDataCenterTransportNodeName.
|
|
2. Switch to REMOTE_TUNNEL_VRF context.
|
|
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the BGP neighbor status.
|
|
4. Alternatively, invoke the NSX API GET /api/v1/transport-nodes/<transport-node-id>/inter-site/bgp/summary
|
|
to get the BGP neighbor status.
|
|
5. Invoke the NSX CLI command `get interfaces` and check if the correct RTEP IP address is assigned
|
|
to the interface with name remote-tunnel-endpoint.
|
|
6. Check if the ping is working successfully between assigned RTEP IP address and the RTEP IP addresses
|
|
on the remote location vmwNsxTDataCenterRemoteSiteName.
|
|
7. Check /var/log/syslog for any errors related to BGP.
|
|
8. Invoke the NSX API GET or PUT /api/v1/transport-nodes/<transport-node-id> to get/update remote_tunnel_endpoint
|
|
configuration on the edge node.
|
|
This will update the RTEP IP assigned to the affected edge node vmwNsxTDataCenterTransportNodeName.
|
|
"
|
|
::= { vmwNsxTFederationFeature 7 }
|
|
|
|
vmwNsxTFederationRtepConnectivityLostClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterRemoteSiteName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Edge node vmwNsxTDataCenterTransportNodeName has restored RTEP (Remote Tunnel Endpoint) connectivity
|
|
with remote location vmwNsxTDataCenterRemoteSiteName.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTFederationFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- GatewayFirewall feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTGatewayFirewallFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the GatewayFirewall feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 39 }
|
|
|
|
vmwNsxTGatewayFirewallFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for GatewayFirewall feature notifications.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeaturePrefix 0 }
|
|
|
|
vmwNsxTGatewayFirewallICMPFlowCountExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for ICMP traffic on logical
|
|
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above the
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usage for ICMP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 21 }
|
|
|
|
vmwNsxTGatewayFirewallICMPFlowCountExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 22 }
|
|
|
|
vmwNsxTGatewayFirewallICMPFlowCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for ICMP on logical router vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usege for ICMP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 23 }
|
|
|
|
vmwNsxTGatewayFirewallICMPFlowCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for ICMP on logical router
|
|
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 24 }
|
|
|
|
vmwNsxTGatewayFirewallIPFlowCountExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallIPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for IP traffic on logical router vmwNsxTDataCenterEntityId has
|
|
reached vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usage for IP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 25 }
|
|
|
|
vmwNsxTGatewayFirewallIPFlowCountExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 26 }
|
|
|
|
vmwNsxTGatewayFirewallIPFlowCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallIPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for IP on logical router vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterFirewallIPFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usege for IP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 27 }
|
|
|
|
vmwNsxTGatewayFirewallIPFlowCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for non IP flows on logical router
|
|
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 28 }
|
|
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for TCP half-open traffic on logical
|
|
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or above the
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usage for TCP half-open flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 29 }
|
|
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 30 }
|
|
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for TCP on logical router vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usege for TCP half-open flow.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 31 }
|
|
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for TCP half-open on logical router
|
|
vmwNsxTDataCenterEntityId has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 32 }
|
|
|
|
vmwNsxTGatewayFirewallUDPFlowCountExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for UDP traffic on logical
|
|
router vmwNsxTDataCenterEntityId has reached vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above the
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usage for UDP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 33 }
|
|
|
|
vmwNsxTGatewayFirewallUDPFlowCountExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage on logical router vmwNsxTDataCenterEntityId has reached
|
|
below the high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 34 }
|
|
|
|
vmwNsxTGatewayFirewallUDPFlowCountHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for UDP on logical router vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
New flows will be dropped by Gateway firewall when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> interface stats | json` by using
|
|
right interface uuid and check flow table usege for UDP flows.
|
|
Check traffic flows going through the gateway is not a DOS attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider increasing the alarm threshold or route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 35 }
|
|
|
|
vmwNsxTGatewayFirewallUDPFlowCountHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Gateway firewall flow table usage for UDP on logical router
|
|
vmwNsxTDataCenterEntityId has reached below the high threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGatewayFirewallFeature 36 }
|
|
|
|
-- **********************************************************
|
|
-- Groups feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTGroupsFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Groups feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 54 }
|
|
|
|
vmwNsxTGroupsFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Groups feature notifications.
|
|
"
|
|
::= { vmwNsxTGroupsFeaturePrefix 0 }
|
|
|
|
vmwNsxTGroupsGroupSizeLimitExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterGroupId,
|
|
vmwNsxTDataCenterGroupSize,
|
|
vmwNsxTDataCenterGroupMaxNumberLimit,
|
|
vmwNsxTDataCenterIPCount,
|
|
vmwNsxTDataCenterMacCount,
|
|
vmwNsxTDataCenterVifCount,
|
|
vmwNsxTDataCenterLspCount,
|
|
vmwNsxTDataCenterLrpCount,
|
|
vmwNsxTDataCenterSidCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group vmwNsxTDataCenterGroupId has at least vmwNsxTDataCenterGroupSize translated elements which is at or greater
|
|
than the maximum numbers limit of vmwNsxTDataCenterGroupMaxNumberLimit. This can result
|
|
in long processing times and can lead to timeouts and outages. The current
|
|
count for each element type is as follows. IP sets:vmwNsxTDataCenterIPCount, MAC
|
|
sets:vmwNsxTDataCenterMacCount, VIFS:vmwNsxTDataCenterVifCount, Logical switch ports:vmwNsxTDataCenterLspCount,
|
|
Logical router ports:vmwNsxTDataCenterLrpCount, AdGroups:vmwNsxTDataCenterSidCount.
|
|
|
|
Action required:
|
|
1. Consider adjusting group elements in oversized group vmwNsxTDataCenterGroupId.
|
|
2. Consider splitting oversized group vmwNsxTDataCenterGroupId to multiple smaller groups and distributing members of oversized group to these groups.
|
|
"
|
|
::= { vmwNsxTGroupsFeature 3 }
|
|
|
|
vmwNsxTGroupsGroupSizeLimitExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterGroupId,
|
|
vmwNsxTDataCenterGroupMaxNumberLimit
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Total number of elements in group vmwNsxTDataCenterGroupId is below the maximum limit of
|
|
vmwNsxTDataCenterGroupMaxNumberLimit.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTGroupsFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- HighAvailability feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTHighAvailabilityFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the HighAvailability feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 21 }
|
|
|
|
vmwNsxTHighAvailabilityFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for HighAvailability feature notifications.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeaturePrefix 0 }
|
|
|
|
vmwNsxTHighAvailabilityTier0GatewayFailover NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPreviousGatewayState,
|
|
vmwNsxTDataCenterCurrentGatewayState,
|
|
vmwNsxTDataCenterServiceRouterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tier0 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState
|
|
to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxTDataCenterServiceRouterId.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-router <service_router_id>` to
|
|
identify the tier0 service-router vrf ID. Switch to the vrf context by
|
|
invoking `vrf <vrf-id>` then invoke `get high-availability status`
|
|
to determine the service that is down.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 9 }
|
|
|
|
vmwNsxTHighAvailabilityTier0GatewayFailoverClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tier0 gateway vmwNsxTDataCenterEntityId is now up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 10 }
|
|
|
|
vmwNsxTHighAvailabilityTier0ServiceGroupFailover NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHaState,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterHaState2,
|
|
vmwNsxTDataCenterTransportNodeId2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service-group cluster vmwNsxTDataCenterEntityId currently does not have an active
|
|
instance. It is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is standby and
|
|
2 is active) on Edge node vmwNsxTDataCenterTransportNodeId and in state vmwNsxTDataCenterHaState2
|
|
on Edge node vmwNsxTDataCenterTransportNodeId2.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-router <service_router_id> service_group` to
|
|
check all service-groups configured under a given service-router. Examine
|
|
the output for reason for a service-group leaving active state.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 13 }
|
|
|
|
vmwNsxTHighAvailabilityTier0ServiceGroupFailoverClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tier0 service-group cluster vmwNsxTDataCenterEntityId now has one active instance
|
|
on Edge node vmwNsxTDataCenterTransportNodeId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 14 }
|
|
|
|
vmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancy NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceRouterId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service-group cluster vmwNsxTDataCenterEntityId attached to Tier0 service-router
|
|
vmwNsxTDataCenterServiceRouterId on Edge node vmwNsxTDataCenterTransportNodeId has failed.
|
|
As a result, the service-group cluster currently does not have a
|
|
standby instance.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-router <service_router_id> service_group` to
|
|
check all service-groups configured under a given service-router. Examine
|
|
the output for failure reason for a previously standby service-group.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 17 }
|
|
|
|
vmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancyClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHaState,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterHaState2,
|
|
vmwNsxTDataCenterTransportNodeId2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service-group cluster vmwNsxTDataCenterEntityId is in state vmwNsxTDataCenterHaState (where 0 is down,
|
|
1 is standby and 2 is active) on Edge node vmwNsxTDataCenterTransportNodeId
|
|
and state vmwNsxTDataCenterHaState2 on Edge node vmwNsxTDataCenterTransportNodeId2.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 18 }
|
|
|
|
vmwNsxTHighAvailabilityTier1GatewayFailover NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPreviousGatewayState,
|
|
vmwNsxTDataCenterCurrentGatewayState,
|
|
vmwNsxTDataCenterServiceRouterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tier1 gateway vmwNsxTDataCenterEntityId failover from vmwNsxTDataCenterPreviousGatewayState
|
|
to vmwNsxTDataCenterCurrentGatewayState, service-router vmwNsxTDataCenterServiceRouterId.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-router <service_router_id>` to
|
|
identify the tier1 service-router vrf ID. Switch to the vrf context by
|
|
invoking `vrf <vrf-id>` then invoke `get high-availability status`
|
|
to determine the service that is down.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 11 }
|
|
|
|
vmwNsxTHighAvailabilityTier1GatewayFailoverClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tier1 gateway vmwNsxTDataCenterEntityId is now up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 12 }
|
|
|
|
vmwNsxTHighAvailabilityTier1ServiceGroupFailover NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHaState,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterHaState2,
|
|
vmwNsxTDataCenterTransportNodeId2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service-group cluster vmwNsxTDataCenterEntityId currently does not have an active
|
|
instance. It is in state vmwNsxTDataCenterHaState (where 0 is down, 1 is standby and
|
|
2 is active) on Edge node vmwNsxTDataCenterTransportNodeId and in state vmwNsxTDataCenterHaState2
|
|
on Edge node vmwNsxTDataCenterTransportNodeId2.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-router <service_router_id> service_group` to
|
|
check all service-groups configured under a given service-router. Examine
|
|
the output for reason for a service-group leaving active state.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 15 }
|
|
|
|
vmwNsxTHighAvailabilityTier1ServiceGroupFailoverClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tier1 service-group cluster vmwNsxTDataCenterEntityId now has one active instance
|
|
on Edge node vmwNsxTDataCenterTransportNodeId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 16 }
|
|
|
|
vmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancy NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceRouterId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service-group cluster vmwNsxTDataCenterEntityId attached to Tier1 service-router
|
|
vmwNsxTDataCenterServiceRouterId on Edge node vmwNsxTDataCenterTransportNodeId has failed.
|
|
As a result, the service-group cluster currently does not have a
|
|
standby instance.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-router <service_router_id> service_group` to
|
|
check all service-groups configured under a given service-router. Examine
|
|
the output for failure reason for a previously standby service-group.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 19 }
|
|
|
|
vmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancyClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterHaState,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterHaState2,
|
|
vmwNsxTDataCenterTransportNodeId2
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service-group cluster vmwNsxTDataCenterEntityId is in state vmwNsxTDataCenterHaState (where 0 is down,
|
|
1 is standby and 2 is active) on Edge node vmwNsxTDataCenterTransportNodeId
|
|
and state vmwNsxTDataCenterHaState2 on Edge node vmwNsxTDataCenterTransportNodeId2.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTHighAvailabilityFeature 20 }
|
|
|
|
-- **********************************************************
|
|
-- IdentityFirewall feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTIdentityFirewallFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the IdentityFirewall feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 36 }
|
|
|
|
vmwNsxTIdentityFirewallFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for IdentityFirewall feature notifications.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeaturePrefix 0 }
|
|
|
|
vmwNsxTIdentityFirewallConnectivityToLDAPServerLost NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLDAPServer
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is lost.
|
|
|
|
Action required:
|
|
Check
|
|
1. The LDAP server is reachable from NSX nodes.
|
|
2. The LDAP server details are configured correctly in NSX.
|
|
3. The LDAP server is running correctly.
|
|
4. There are no firewalls blocking access between the LDAP server
|
|
and NSX nodes.
|
|
Afer the issue is fixed, use TEST CONNECTION in NSX UI under
|
|
Identity Firewall AD to test the connection.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeature 1 }
|
|
|
|
vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLDAPServer
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The connectivity to LDAP server vmwNsxTDataCenterLDAPServer is restored.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeature 2 }
|
|
|
|
vmwNsxTIdentityFirewallErrorInDeltaSync NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDirectoryDomain
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain.
|
|
|
|
Action required:
|
|
1. Check if there are any connectivity to LDAP server lost alarms.
|
|
2. Find the error details in /var/log/syslog. Around the alarm trigger
|
|
time, search for text: Error happened when synchronize LDAP objects.
|
|
3. Check with AD administrator if there are any recent AD changes which
|
|
may cause the errors.
|
|
4. If the errors persist, collect the technical support bundle and
|
|
contact VMware technical support.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeature 3 }
|
|
|
|
vmwNsxTIdentityFirewallErrorInDeltaSyncClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDirectoryDomain
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"No errors occurred while performing delta sync with vmwNsxTDataCenterDirectoryDomain.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIdentityFirewallFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- InfrastructureCommunication feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTInfrastructureCommunicationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the InfrastructureCommunication feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 7 }
|
|
|
|
vmwNsxTInfrastructureCommunicationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for InfrastructureCommunication feature notifications.
|
|
"
|
|
::= { vmwNsxTInfrastructureCommunicationFeaturePrefix 0 }
|
|
|
|
vmwNsxTInfrastructureCommunicationEdgeTunnelsDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The overall tunnel status of Edge node vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get tunnel-ports` to get all tunnel ports,
|
|
then check each tunnel's stats by invoking NSX CLI command
|
|
`get tunnel-port <UUID> stats` to check if there are any drops. Also
|
|
check /var/log/syslog if there are tunnel related errors.
|
|
"
|
|
::= { vmwNsxTInfrastructureCommunicationFeature 17 }
|
|
|
|
vmwNsxTInfrastructureCommunicationEdgeTunnelsDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tunnels of Edge node vmwNsxTDataCenterEntityId have been restored.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureCommunicationFeature 18 }
|
|
|
|
-- **********************************************************
|
|
-- InfrastructureService feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTInfrastructureServiceFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the InfrastructureService feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 19 }
|
|
|
|
vmwNsxTInfrastructureServiceFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for InfrastructureService feature notifications.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeaturePrefix 0 }
|
|
|
|
vmwNsxTInfrastructureServiceApplicationCrashed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNodeDisplayOrHostName,
|
|
vmwNsxTDataCenterCoreDumpCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Application on NSX node vmwNsxTDataCenterNodeDisplayOrHostName has crashed.
|
|
The number of core files found is vmwNsxTDataCenterCoreDumpCount.
|
|
Collect the Support Bundle including core dump files
|
|
and contact VMware Support team.
|
|
|
|
Action required:
|
|
Collect Support Bundle for NSX node vmwNsxTDataCenterNodeDisplayOrHostName
|
|
using NSX Manager UI or API.
|
|
Note, core dumps can be set to move or copy into NSX Tech Support Bundle
|
|
in order to remove or preserve the local copy on node.
|
|
Copy of Support Bundle with core dump files is essential for
|
|
VMware Support team to troubleshoot the issue and it is best recommended to
|
|
save a latest copy of Tech Support Bundle including core dump files
|
|
before removing core dump files from system.
|
|
Refer KB article for more details.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 9 }
|
|
|
|
vmwNsxTInfrastructureServiceApplicationCrashedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All core dump files are withdrawn from system.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 10 }
|
|
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeServiceName,
|
|
vmwNsxTDataCenterPreviousServiceState,
|
|
vmwNsxTDataCenterCurrentServiceState,
|
|
vmwNsxTDataCenterServiceDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState
|
|
to vmwNsxTDataCenterCurrentServiceState.
|
|
vmwNsxTDataCenterServiceDownReason
|
|
|
|
Action required:
|
|
On the Edge node, verify the service hasn't exited due to an error by
|
|
looking for core files in the /var/log/core directory. In addition,
|
|
invoke the NSX CLI command `get services` to confirm whether the service
|
|
is stopped. If so, invoke `start service <service-name>` to restart the
|
|
service.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 1 }
|
|
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusChangedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeServiceName,
|
|
vmwNsxTDataCenterPreviousServiceState,
|
|
vmwNsxTDataCenterCurrentServiceState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterEdgeServiceName changed from vmwNsxTDataCenterPreviousServiceState
|
|
to vmwNsxTDataCenterCurrentServiceState.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 2 }
|
|
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeServiceName,
|
|
vmwNsxTDataCenterServiceDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterEdgeServiceName is down for at least one minute.
|
|
vmwNsxTDataCenterServiceDownReason
|
|
|
|
Action required:
|
|
On the Edge node, verify the service hasn't exited due to an error by
|
|
looking for core files in the /var/log/core directory. In addition,
|
|
invoke the NSX CLI command `get services` to confirm whether the service
|
|
is stopped. If so, invoke `start service <service-name>` to restart the
|
|
service.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 3 }
|
|
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEdgeServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterEdgeServiceName is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 4 }
|
|
|
|
vmwNsxTInfrastructureServiceMetricsDeliveryFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMetricsTargetAlias,
|
|
vmwNsxTDataCenterMetricsTargetAddress,
|
|
vmwNsxTDataCenterMetricsTargetPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Failed to deliver metrics from SHA to target vmwNsxTDataCenterMetricsTargetAlias(vmwNsxTDataCenterMetricsTargetAddress:vmwNsxTDataCenterMetricsTargetPort).
|
|
|
|
Action required:
|
|
User should perform the following checks in order to exclude the problem causing the failure:
|
|
1. Check if target address vmwNsxTDataCenterMetricsTargetAddress and port vmwNsxTDataCenterMetricsTargetPort (default is 443 in the case port is not specified)
|
|
passed down to connect is the expected target,
|
|
2. Check if the certificate is correct by
|
|
`/opt/vmware/nsx-nestdb/bin/nestdb-cli --cmd 'put vmware.nsx.nestdb.CommonAgentHostConfigMsg'`,
|
|
3. Check if target vmwNsxTDataCenterMetricsTargetAddress is reachable,
|
|
4. Check if the metric manager on target vmwNsxTDataCenterMetricsTargetAddress is running by `docker ps | grep metrics_manager`,
|
|
5. Check if port vmwNsxTDataCenterMetricsTargetPort is opened by `netstat -a | grep vmwNsxTDataCenterMetricsTargetPort` on target,
|
|
6. Check if ALLOW firewall rule is installed on the node by `iptables -S OUTPUT | grep vmwNsxTDataCenterMetricsTargetPort`(EDGE/UA) or
|
|
`localcli network firewall ruleset list | grep nsx-sha-tsdb`(ESX),
|
|
7. Restart SHA daemon to see if it could be solved by `/etc/init.d/netopa restart`(ESX) or `/etc/init.d/nsx-netopa restart`(EDGE)
|
|
or `/etc/init.d/nsx-sha restart`(UA).
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 19 }
|
|
|
|
vmwNsxTInfrastructureServiceMetricsDeliveryFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMetricsTargetAlias,
|
|
vmwNsxTDataCenterMetricsTargetAddress,
|
|
vmwNsxTDataCenterMetricsTargetPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Metrics delivery to target vmwNsxTDataCenterMetricsTargetAlias(vmwNsxTDataCenterMetricsTargetAddress:vmwNsxTDataCenterMetricsTargetPort) recovered.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 20 }
|
|
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterServiceName has been unresponsive for 10 seconds.
|
|
|
|
Action required:
|
|
Verify vmwNsxTDataCenterServiceName service is still running by invoking `/etc/init.d/vmwNsxTDataCenterServiceName status`.
|
|
If the service is reported as running, it may need to get restarted which can be done by
|
|
`/etc/init.d/vmwNsxTDataCenterServiceName restart`. Rerun the status command to verify the service is now
|
|
running. If the script `/etc/init.d/vmwNsxTDataCenterServiceName` is unavailable, invoke
|
|
`systemctl vmwNsxTDataCenterServiceName status` and restart by `systemctl vmwNsxTDataCenterServiceName restart` with root
|
|
priviledges. If restarting the service does not resolve the issue or if the issue reoccurs after
|
|
a successful restart, contact VMware Support.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 7 }
|
|
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterServiceName is responsive again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 8 }
|
|
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknownOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterServiceName on DPU vmwNsxTDataCenterDPUId has been unresponsive for 10 seconds.
|
|
|
|
Action required:
|
|
Verify vmwNsxTDataCenterServiceName service on DPU vmwNsxTDataCenterDPUId is still running by invoking
|
|
`/etc/init.d/vmwNsxTDataCenterServiceName status`. If the service is reported as running, it may
|
|
need to get restarted which can be done by `/etc/init.d/vmwNsxTDataCenterServiceName restart`.
|
|
Rerun the status command to verify the service is now running. If restarting the
|
|
service does not resolve the issue or if the issue reoccurs after a successful restart,
|
|
contact VMware Support.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 11 }
|
|
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknownOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service vmwNsxTDataCenterServiceName on DPU vmwNsxTDataCenterDPUId is responsive again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTInfrastructureServiceFeature 12 }
|
|
|
|
-- **********************************************************
|
|
-- IntelligenceCommunication feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTIntelligenceCommunicationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the IntelligenceCommunication feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 9 }
|
|
|
|
vmwNsxTIntelligenceCommunicationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for IntelligenceCommunication feature notifications.
|
|
"
|
|
::= { vmwNsxTIntelligenceCommunicationFeaturePrefix 0 }
|
|
|
|
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnected NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from
|
|
the Intelligence node's messaging broker. Data collection is affected.
|
|
|
|
Action required:
|
|
Restart the messaging service if it is not running in the Intelligence
|
|
node. Resolve the network connection failure between the Transport node
|
|
flow exporter and the Intelligence node.
|
|
"
|
|
::= { vmwNsxTIntelligenceCommunicationFeature 7 }
|
|
|
|
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to
|
|
the Intelligence node's messaging broker.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceCommunicationFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- IntelligenceHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTIntelligenceHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the IntelligenceHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 6 }
|
|
|
|
vmwNsxTIntelligenceHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for IntelligenceHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTIntelligenceHealthCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Use the top command to check which processes have the most CPU usages, and
|
|
then check /var/log/syslog and these processes' local logs to see if there
|
|
are any outstanding errors to be resolved.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 41 }
|
|
|
|
vmwNsxTIntelligenceHealthCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 42 }
|
|
|
|
vmwNsxTIntelligenceHealthCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Use the top command to check which processes have the most CPU usages, and
|
|
then check /var/log/syslog and these processes' local logs to see if there
|
|
are any outstanding errors to be resolved.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 43 }
|
|
|
|
vmwNsxTIntelligenceHealthCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 44 }
|
|
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition /data on Intelligence node
|
|
vmwNsxTDataCenterIntelligenceNodeId is above the high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Stop NSX intelligence data collection until the disk usage is below
|
|
the threshold. Examine disk partition /data and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 45 }
|
|
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition /data on Intelligence node
|
|
vmwNsxTDataCenterIntelligenceNodeId is below the high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 46 }
|
|
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition /data on Intelligence node
|
|
vmwNsxTDataCenterIntelligenceNodeId is above the very high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Stop NSX intelligence data collection until the disk usage is below
|
|
the threshold. In the NSX UI, navigate to System | Appliances | NSX
|
|
Intelligence Appliance. Then click ACTONS, Stop Collecting Data.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 47 }
|
|
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition /data on Intelligence node
|
|
vmwNsxTDataCenterIntelligenceNodeId is below the very high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 48 }
|
|
|
|
vmwNsxTIntelligenceHealthDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine disk partition vmwNsxTDataCenterDiskPartitionName and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 49 }
|
|
|
|
vmwNsxTIntelligenceHealthDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 50 }
|
|
|
|
vmwNsxTIntelligenceHealthDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine disk partition vmwNsxTDataCenterDiskPartitionName and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 51 }
|
|
|
|
vmwNsxTIntelligenceHealthDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 52 }
|
|
|
|
vmwNsxTIntelligenceHealthMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Use the top command to check which processes have the most memory usages,
|
|
and then check /var/log/syslog and these processes' local logs to see if
|
|
there are any outstanding errors to be resolved.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 53 }
|
|
|
|
vmwNsxTIntelligenceHealthMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 54 }
|
|
|
|
vmwNsxTIntelligenceHealthMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Use the top command to check which processes have the most memory usages,
|
|
and then check /var/log/syslog and these processes' local logs to see if
|
|
there are any outstanding errors to be resolved.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 55 }
|
|
|
|
vmwNsxTIntelligenceHealthMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Intelligence node vmwNsxTDataCenterIntelligenceNodeId
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 56 }
|
|
|
|
vmwNsxTIntelligenceHealthNodeStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterIntelligenceNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Intelligence node vmwNsxTDataCenterIntelligenceNodeId is degraded.
|
|
|
|
Action required:
|
|
Invoke the NSX API GET /napp/api/v1/platform/monitor/category/health to
|
|
check which specific pod is down and the reason behind it. Invoke the following
|
|
CLI command to restart the degraded service:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 57 }
|
|
|
|
vmwNsxTIntelligenceHealthNodeStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterIntelligenceNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Intelligence node vmwNsxTDataCenterIntelligenceNodeId is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 58 }
|
|
|
|
vmwNsxTIntelligenceHealthStorageLatencyHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is above
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold milliseconds.
|
|
|
|
Action required:
|
|
Transient high storage latency may happen due to spike of I/O requests.
|
|
If storage latency remains high for more than 30 minutes,
|
|
consider deploying NSX Intelligence appliance in a low latency disk,
|
|
or not sharing the same storage device with other VMs.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 63 }
|
|
|
|
vmwNsxTIntelligenceHealthStorageLatencyHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The storage latency of disk partition vmwNsxTDataCenterDiskPartitionName on
|
|
Intelligence node vmwNsxTDataCenterIntelligenceNodeId is below
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold milliseconds.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIntelligenceHealthFeature 64 }
|
|
|
|
-- **********************************************************
|
|
-- IPAM feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTIPAMFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the IPAM feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 38 }
|
|
|
|
vmwNsxTIPAMFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for IPAM feature notifications.
|
|
"
|
|
::= { vmwNsxTIPAMFeaturePrefix 0 }
|
|
|
|
vmwNsxTIPAMIPBlockUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP block usage of vmwNsxTDataCenterIntentPath is very high.
|
|
IP block nearing its total capacity, creation of subnet using IP block might fail.
|
|
|
|
Action required:
|
|
Review IP block usage. Use new IP block for resource creation or delete unused IP
|
|
subnet from the IP block. To check subnet being used for IP Block. From NSX UI,
|
|
navigate to Networking | IP Address pools | IP Address pools tab. Select IP pools
|
|
where IP block being used, check Subnets and Allocated IPs column on UI. If no
|
|
allocation has been used for the IP pool and it is not going to be used in future
|
|
then delete subnet or IP pool. Use following API to check if IP block being used
|
|
by IP pool and also check if any IP allocation done:
|
|
To get configured subnets of an IP pool, invoke the NSX API
|
|
GET /policy/api/v1/infra/ip-pools/<ip-pool>/ip-subnets
|
|
To get IP allocations, invoke the NSX API
|
|
GET /policy/api/v1/infra/ip-pools/<ip-pool>/ip-allocations
|
|
Note: Deletion of IP pool/subnet should only be done if it does not have any
|
|
allocated IPs and it is not going to be used in future.
|
|
"
|
|
::= { vmwNsxTIPAMFeature 1 }
|
|
|
|
vmwNsxTIPAMIPBlockUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP block usage of vmwNsxTDataCenterIntentPath is below threshold level.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIPAMFeature 2 }
|
|
|
|
vmwNsxTIPAMIPPoolUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP pool usage of vmwNsxTDataCenterIntentPath is very high.
|
|
Creation of entity/service depends on IP being allocated from IP pool might fail.
|
|
|
|
Action required:
|
|
Review IP pool usage.
|
|
Release unused ip allocations from IP pool or create new IP pool and use it.
|
|
From NSX UI navigate to Networking | IP Address pools | IP Address pools tab.
|
|
Select IP pools and check Allocated IPs column, this will show IPs allocated from the
|
|
IP pool. If user see any IPs are not being used then those IPs can be released.
|
|
To release unused IP allocations, invoke the NSX API
|
|
DELETE /policy/api/v1/infra/ip-pools/<ip-pool>/ip-allocations/<ip-allocation>
|
|
"
|
|
::= { vmwNsxTIPAMFeature 3 }
|
|
|
|
vmwNsxTIPAMIPPoolUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP pool usage of vmwNsxTDataCenterIntentPath is normal now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTIPAMFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- Licenses feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTLicensesFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Licenses feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 5 }
|
|
|
|
vmwNsxTLicensesFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Licenses feature notifications.
|
|
"
|
|
::= { vmwNsxTLicensesFeaturePrefix 0 }
|
|
|
|
vmwNsxTLicensesLicenseExpired NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterDisplayedLicenseKey
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vmwNsxTDataCenterLicenseEditionType license key ending with
|
|
vmwNsxTDataCenterDisplayedLicenseKey, has expired.
|
|
|
|
Action required:
|
|
Add a new, non-expired license using the NSX UI by navigating to
|
|
System | Licenses then click ADD and specify the key of the new
|
|
license. The expired license should be deleted by checking the
|
|
checkbox of the license, then click DELETE.
|
|
"
|
|
::= { vmwNsxTLicensesFeature 1 }
|
|
|
|
vmwNsxTLicensesLicenseExpiredClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterDisplayedLicenseKey
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expired vmwNsxTDataCenterLicenseEditionType license key ending with
|
|
vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no
|
|
longer about to expire.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLicensesFeature 2 }
|
|
|
|
vmwNsxTLicensesLicenseIsAboutToExpire NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterDisplayedLicenseKey
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The vmwNsxTDataCenterLicenseEditionType license key ending with
|
|
vmwNsxTDataCenterDisplayedLicenseKey, is about to expire.
|
|
|
|
Action required:
|
|
The license is about to expire in several days. Plan to add a
|
|
new, non-expiring license using the NSX UI by navigating to System |
|
|
Licenses then click ADD and specify the key of the new license. The
|
|
expired license should be deleted by checking the checkbox of the
|
|
license, then click DELETE.
|
|
"
|
|
::= { vmwNsxTLicensesFeature 3 }
|
|
|
|
vmwNsxTLicensesLicenseIsAboutToExpireClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterDisplayedLicenseKey
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The expiring vmwNsxTDataCenterLicenseEditionType license key ending with
|
|
vmwNsxTDataCenterDisplayedLicenseKey, has been removed, updated or is no
|
|
longer about to expire.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLicensesFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- LoadBalancer feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTLoadBalancerFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the LoadBalancer feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 17 }
|
|
|
|
vmwNsxTLoadBalancerFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for LoadBalancer feature notifications.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeaturePrefix 0 }
|
|
|
|
vmwNsxTLoadBalancerDLBStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distributed load balancer service vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
On ESXi host node, invoke the NSX CLI command `get load-balancer
|
|
<lb-uuid> status`.
|
|
If 'Conflict LSP' is reported, check whether this LSP is attached
|
|
to other load balancer service. Check whether this conflict is
|
|
acceptable.
|
|
If 'Not Ready LSP' is reported, check the status of this LSP by
|
|
invoking NSX CLI command `get logical-switch-port status`.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 17 }
|
|
|
|
vmwNsxTLoadBalancerDLBStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The distributed load balancer service vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 18 }
|
|
|
|
vmwNsxTLoadBalancerLBCPUVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of load balancer vmwNsxTDataCenterEntityId is very high. The threshold is
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
If the load balancer CPU utilization is higher than system usage threshold,
|
|
the workload is too high for this load balancer. Rescale the load balancer
|
|
service by changing the load balancer size from small to medium or from
|
|
medium to large. If the CPU utilization of this load balancer is still high,
|
|
consider adjusting the Edge appliance form factor size or moving load
|
|
balancer services to other Edge nodes for the applicable workload.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 1 }
|
|
|
|
vmwNsxTLoadBalancerLBCPUVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of load balancer vmwNsxTDataCenterEntityId is low enough. The threshold is
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 2 }
|
|
|
|
vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is high.
|
|
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
If multiple LB instances have been configurerd in this Edge node, deploy a
|
|
new Edge node and move some LB instances to that new Edge node. If only a
|
|
single LB instance (small/medium/etc) has been configured in an Edge node of
|
|
same size (small/medium/etc), deploy a new Edge of bigger size and move the
|
|
LB instance to that new Edge node.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 3 }
|
|
|
|
vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of load balancer service in Edge node vmwNsxTDataCenterEntityId is low enough.
|
|
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 4 }
|
|
|
|
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of pool members in Edge node vmwNsxTDataCenterEntityId is very high.
|
|
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Deploy a new Edge node and move the load balancer service from existing Edge
|
|
nodes to the newly deployed Edge node.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 5 }
|
|
|
|
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The usage of pool members in Edge node vmwNsxTDataCenterEntityId is low enough.
|
|
The threshold is vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 6 }
|
|
|
|
vmwNsxTLoadBalancerLBStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer service vmwNsxTDataCenterEntityId is degraded.
|
|
|
|
Action required:
|
|
For centralized load balancer:
|
|
Check the load balancer status on standby Edge node as the degraded status
|
|
means the load balancer status on standby Edge node is not ready. On standby
|
|
Edge node, invoke the NSX CLI command `get load-balancer <lb-uuid> status`.
|
|
If the LB-State of load balancer service is not_ready or there is no output,
|
|
make the Edge node enter maintenance mode, then exit maintenance mode.
|
|
For distributed load balancer:
|
|
1. Get detailed status by invoking NSX API GET
|
|
/policy/api/v1/infra/lb-services/<LBService>/detailed-status?source=realtime
|
|
2. From API output, find ESXi host reporting a non-zero instance_number
|
|
with status NOT_READY or CONFLICT.
|
|
3. On ESXi host node, invoke the NSX CLI command `get load-balancer
|
|
<lb-uuid> status`.
|
|
If 'Conflict LSP'is reported, check whether this LSP is attached
|
|
to other load balancer service. Check whether this conflict is
|
|
acceptable.
|
|
If 'Not Ready LSP' is reported, check the status of this LSP by
|
|
invoking NSX CLI command `get logical-switch-port status`.
|
|
NOTE: You should ignore the alarm if it can be resolved automatically in 5 mins
|
|
because the degraded status can be a transient status.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 15 }
|
|
|
|
vmwNsxTLoadBalancerLBStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer service vmwNsxTDataCenterEntityId is not degraded.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 16 }
|
|
|
|
vmwNsxTLoadBalancerLBStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The centralized load balancer service vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
On active Edge node, check load balancer status by invoking the NSX CLI
|
|
command `get load-balancer <lb-uuid> status`. If the LB-State of load
|
|
balancer service is not_ready or there is no output, make the Edge node
|
|
enter maintenance mode, then exit maintenance mode.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 7 }
|
|
|
|
vmwNsxTLoadBalancerLBStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The centralized load balancer service vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 8 }
|
|
|
|
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer configuration vmwNsxTDataCenterEntityId is not realized,
|
|
due to high memory usage on Edge node vmwNsxTDataCenterTransportNodeId.
|
|
|
|
Action required:
|
|
Prefer defining small and medium sized load balancers over large sized load balancers.
|
|
Spread out load balancer services among the available Edge nodes.
|
|
Reduce number of Virtual Servers defined.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 19 }
|
|
|
|
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer configuration vmwNsxTDataCenterEntityId is realized on vmwNsxTDataCenterTransportNodeId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 20 }
|
|
|
|
vmwNsxTLoadBalancerPoolStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer pool vmwNsxTDataCenterEntityId status is down.
|
|
|
|
Action required:
|
|
Consult the load balancer pool to determine which members are down by
|
|
invoking the NSX CLI command
|
|
`get load-balancer <lb-uuid> pool <pool-uuid> status`
|
|
or NSX API GET
|
|
/policy/api/v1/infra/lb-services/<lb-service-id>/lb-pools/<lb-pool-id>/detailed-status
|
|
If DOWN or UNKNOWN is reported, verify the pool member.
|
|
Check network connectivity from the load balancer to the impacted pool members.
|
|
Validate application health of each pool member. Also validate the health
|
|
of each pool member using the configured monitor. When the health of the
|
|
member is established, the pool member status is updated to healthy based
|
|
on the 'Rise Count' configuration in the monitor.
|
|
Remediate the issue by rebooting the pool member or make the Edge node
|
|
enter maintenance mode, then exit maintenance mode.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 9 }
|
|
|
|
vmwNsxTLoadBalancerPoolStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer pool vmwNsxTDataCenterEntityId status is up
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 10 }
|
|
|
|
vmwNsxTLoadBalancerVirtualServerStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer virtual server vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Consult the load balancer pool to determine its status and verify its
|
|
configuration. If incorrectly configured, reconfigure it and remove the
|
|
load balancer pool from the virtual server then re-add it to the
|
|
virtual server again.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 11 }
|
|
|
|
vmwNsxTLoadBalancerVirtualServerStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The load balancer virtual server vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTLoadBalancerFeature 12 }
|
|
|
|
-- **********************************************************
|
|
-- MalwarePreventionHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTMalwarePreventionHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the MalwarePreventionHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 48 }
|
|
|
|
vmwNsxTMalwarePreventionHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for MalwarePreventionHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachable NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to
|
|
communicate with analyst_api service. Inspected file verdicts may not be up to date.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which
|
|
service is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to
|
|
check which specific service is down and the reason behind it. Invoke the following CLI command
|
|
to restart the degraded service:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
Determine the status of Malware Prevention Cloud Connector service.
|
|
|
|
For more information see:
|
|
https://www.vmware.com/esx/support/askvmware/index.php?eventtype=malware_prevention_health.analyst_api_service_unreachable
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 1 }
|
|
|
|
vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachableClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 2 }
|
|
|
|
vmwNsxTMalwarePreventionHealthDatabaseUnreachable NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to
|
|
communicate with Malware Prevention database.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which
|
|
service is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to
|
|
check which specific service is down and the reason behind it. Invoke the following CLI command
|
|
to restart the degraded service:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
Determine the status of Malware Prevention Database service.
|
|
|
|
For more information see:
|
|
https://www.vmware.com/esx/support/askvmware/index.php?eventtype=malware_prevention_health.database_unreachable
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 3 }
|
|
|
|
vmwNsxTMalwarePreventionHealthDatabaseUnreachableClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 4 }
|
|
|
|
vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachable NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterNSXEdgeTNName,
|
|
vmwNsxTDataCenterNSXESXTNName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is degraded on vmwNsxTDataCenterTransportNodeName. Unable to communicate
|
|
with file extraction functionality. All file extraction abilities on the
|
|
vmwNsxTDataCenterTransportNodeName are paused.
|
|
|
|
Action required:
|
|
1. On the Edge node identified by vmwNsxTDataCenterNSXEdgeTNName, invoke the NSX CLI `get ids engine status`
|
|
to check the status of file_extraction (IDS) service. Inspect /var/log/syslog to find any
|
|
suspecting error(s) with the file extraction (IDS) service and/or vmwNsxTDataCenterMpsServiceName.
|
|
2. On the Host node identified by vmwNsxTDataCenterNSXESXTNName, log into the associated Malware Prevention
|
|
Service VM vmwNsxTDataCenterEntityId and check the status of file extraction (NXGI) service. Inspect
|
|
/var/log/syslog on the associated Malware Prevention Service VM vmwNsxTDataCenterEntityId to find any
|
|
suspecting error(s).
|
|
|
|
For more information see:
|
|
https://www.vmware.com/esx/support/askvmware/index.php?eventtype=malware_prevention_health.file_extraction_service_unreachable
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 5 }
|
|
|
|
vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachableClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is running properly on vmwNsxTDataCenterTransportNodeName.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 6 }
|
|
|
|
vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachable NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is degraded on NSX Application Platform. It is unable to
|
|
communicate with NTICS reputation service. Inspected file reputations may not be up to date.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which
|
|
service is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to
|
|
check which specific service is down and the reason behind it. Invoke the following CLI command
|
|
to restart the degraded service:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
Determine if access to NTICS service is down.
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 7 }
|
|
|
|
vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachableClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is running properly on NSX Application Platform.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 8 }
|
|
|
|
vmwNsxTMalwarePreventionHealthServiceStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterNSXEdgeTNName,
|
|
vmwNsxTDataCenterNSXESXTNName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is not running on vmwNsxTDataCenterTransportNodeName.
|
|
|
|
Action required:
|
|
1. On the Edge node identified by vmwNsxTDataCenterNSXEdgeTNName, invoke the NSX CLI `get services`
|
|
to check the status of vmwNsxTDataCenterMpsServiceName. Inspect /var/log/syslog to find any suspecting
|
|
error(s).
|
|
2. On the Host node identified by vmwNsxTDataCenterNSXESXTNName, log into the associated Malware Prevention
|
|
Service VM vmwNsxTDataCenterEntityId and check the status of vmwNsxTDataCenterMpsServiceName. Inspect /var/log/syslog on
|
|
the associated Malware Prevention Service VM vmwNsxTDataCenterEntityId to find any suspecting error(s).
|
|
|
|
For more information see:
|
|
https://www.vmware.com/esx/support/askvmware/index.php?eventtype=malware_prevention_health.service_status_down
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 9 }
|
|
|
|
vmwNsxTMalwarePreventionHealthServiceStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterMpsServiceName,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterMpsServiceName is running properly on vmwNsxTDataCenterTransportNodeName.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMalwarePreventionHealthFeature 10 }
|
|
|
|
-- **********************************************************
|
|
-- ManagerHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTManagerHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the ManagerHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 1 }
|
|
|
|
vmwNsxTManagerHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for ManagerHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTManagerHealthDuplicateIPAddress NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDuplicateIPAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager node vmwNsxTDataCenterEntityId IP address vmwNsxTDataCenterDuplicateIPAddress is
|
|
currently being used by another device in the network.
|
|
|
|
Action required:
|
|
1. Determine which device is using the Manager's IP address
|
|
and assign the device a new IP address. Note, reconfiguring
|
|
the Manager to use a new IP address is not supported.
|
|
2. Ensure the static IP address pool/DHCP server is configured correctly.
|
|
3. Correct the IP address of the device if it is manually assigned.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 17 }
|
|
|
|
vmwNsxTManagerHealthDuplicateIPAddressClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDuplicateIPAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The device using the IP address assigned to Manager node
|
|
vmwNsxTDataCenterEntityId appears to no longer be using vmwNsxTDataCenterDuplicateIPAddress.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 18 }
|
|
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /config has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of rising disk
|
|
usage by the NSX Datastore service under the /config/corfu directory.
|
|
|
|
Action required:
|
|
Run the following tool and contact GSS if any issues are reported
|
|
/opt/vmware/tools/support/inspect_checkpoint_issues.py
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 13 }
|
|
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /config has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 14 }
|
|
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /config has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of high disk usage
|
|
by the NSX Datastore service under the /config/corfu directory.
|
|
|
|
Action required:
|
|
Run the following tool and contact GSS if any issues are reported
|
|
/opt/vmware/tools/support/inspect_checkpoint_issues.py
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 15 }
|
|
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /config has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 16 }
|
|
|
|
vmwNsxTManagerHealthManagerCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the configuration, running services and sizing of this Manager node.
|
|
Consider adjusting the Manager appliance form factor size.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 1 }
|
|
|
|
vmwNsxTManagerHealthManagerCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 2 }
|
|
|
|
vmwNsxTManagerHealthManagerCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the configuration, running services and sizing of this Manager node.
|
|
Consider adjusting the Manager appliance form factor size.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 3 }
|
|
|
|
vmwNsxTManagerHealthManagerCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 4 }
|
|
|
|
vmwNsxTManagerHealthManagerDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine the partition with high usage and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 9 }
|
|
|
|
vmwNsxTManagerHealthManagerDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 10 }
|
|
|
|
vmwNsxTManagerHealthManagerDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Examine the partition with high usage and see if there are any
|
|
unexpected large files that can be removed.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 11 }
|
|
|
|
vmwNsxTManagerHealthManagerDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition vmwNsxTDataCenterDiskPartitionName
|
|
has reached vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 12 }
|
|
|
|
vmwNsxTManagerHealthManagerMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the configuration, running services and sizing of this Manager node.
|
|
Consider adjusting the Manager appliance form factor size.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 5 }
|
|
|
|
vmwNsxTManagerHealthManagerMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 6 }
|
|
|
|
vmwNsxTManagerHealthManagerMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very
|
|
high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Review the configuration, running services and sizing of this Manager node.
|
|
Consider adjusting the Manager appliance form factor size.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 7 }
|
|
|
|
vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage on Manager node vmwNsxTDataCenterEntityId has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 8 }
|
|
|
|
vmwNsxTManagerHealthMissingDNSEntryForManagerFQDN NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DNS configuration for Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterEntityId) is incorrect.
|
|
The Manager node is dual-stack and/or CA-signed API certificate is used, but the IP
|
|
address(es) of the Manager node do not resolve to an FQDN or resolve to different FQDNs.
|
|
|
|
Action required:
|
|
1. Ensure proper DNS servers are configured in the Manager node.
|
|
2. Ensure proper A records and PTR records are configured in the DNS servers
|
|
such that reverse lookup of the IP addresses of the Manager node return the same FQDN,
|
|
and forward lookup of the FQDN return all IP addresses of the Manager node.
|
|
3. Alternatively, if the Manager node is not dual-stack, replace the CA-signed
|
|
certificate for API service type with a self-signed certificate.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 28 }
|
|
|
|
vmwNsxTManagerHealthMissingDNSEntryForManagerFQDNClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterManagerNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DNS configuration for Manager node vmwNsxTDataCenterManagerNodeName (vmwNsxTDataCenterEntityId) is correct.
|
|
Either the Manager node is not dual-stack and CA-signed API certificate is no longer used,
|
|
or the IP address(es) of the Manager node resolve to the same FQDN.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 29 }
|
|
|
|
vmwNsxTManagerHealthMissingDNSEntryForVipFQDN NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterIPv4Address,
|
|
vmwNsxTDataCenterIPv6Address
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case of dual stack or CA-signed API certificate for a NSX Manager,
|
|
virtual IPv4 address vmwNsxTDataCenterIPv4Address and virtual IPv6 address vmwNsxTDataCenterIPv6Address for
|
|
Manager node vmwNsxTDataCenterEntityId should resolve to the same FQDN.
|
|
|
|
Action required:
|
|
Examine the DNS entry for the VIP addresses to see if they resolve to the same FQDN.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 33 }
|
|
|
|
vmwNsxTManagerHealthMissingDNSEntryForVipFQDNClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dual stack VIP addresses for Manager node vmwNsxTDataCenterEntityId resolved to same FQDN.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 34 }
|
|
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /nonconfig has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of rising disk
|
|
usage by the NSX Datastore service under the /nonconfig/corfu directory.
|
|
|
|
Action required:
|
|
run the following tool and contact GSS if any issues are reported
|
|
/opt/vmware/tools/support/inspect_checkpoint_issues.py --nonconfig
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 19 }
|
|
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /nonconfig has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 20 }
|
|
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /nonconfig has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is at or above the very high threshold value
|
|
of vmwNsxTDataCenterSystemUsageThreshold%. This can be an indication of high disk usage
|
|
by the NSX Datastore service under the /nonconfig/corfu directory.
|
|
|
|
Action required:
|
|
Run the following tool and contact GSS if any issues are reported
|
|
/opt/vmware/tools/support/inspect_checkpoint_issues.py --nonconfig
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 21 }
|
|
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage for the Manager node disk partition /nonconfig has reached
|
|
vmwNsxTDataCenterSystemResourceUsage% which is below the very high threshold value of
|
|
vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 22 }
|
|
|
|
vmwNsxTManagerHealthStorageError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The following disk partition on the Manager node vmwNsxTDataCenterEntityId is in
|
|
read-only mode: vmwNsxTDataCenterDiskPartitionName
|
|
|
|
Action required:
|
|
Examine the read-only partition to see if reboot resolves the issue
|
|
or the disk needs to be replaced. Contact GSS for more information.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 23 }
|
|
|
|
vmwNsxTManagerHealthStorageErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDiskPartitionName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The following disk partition on the Manager node vmwNsxTDataCenterEntityId
|
|
has recovered from read-only mode: vmwNsxTDataCenterDiskPartitionName
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTManagerHealthFeature 24 }
|
|
|
|
-- **********************************************************
|
|
-- MTUCheck feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTMTUCheckFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the MTUCheck feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 42 }
|
|
|
|
vmwNsxTMTUCheckFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for MTUCheck feature notifications.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeaturePrefix 0 }
|
|
|
|
vmwNsxTMTUCheckGlobalRouterMTUTooBig NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The global router MTU configuration is bigger than MTU of switches in overlay Transport Zone which connects
|
|
to Tier0 or Tier1. Global router MTU value should be less than all switches MTU value by at least
|
|
a 100 as we require 100 quota for Geneve encapsulation.
|
|
|
|
Action required:
|
|
1. Navigate to System | Fabric | Settings | MTU Configuration Check | Inconsistent on the NSX UI to check
|
|
more mismatch details.
|
|
2. Set the bigger MTU value on switches by invoking the NSX API
|
|
PUT /api/v1/host-switch-profiles/<host-switch-profile-id> with mtu in the
|
|
request body, or API PUT /api/v1/global-configs/SwitchingGlobalConfig
|
|
with physical_uplink_mtu in request body.
|
|
3. Or set the smaller MTU value of global router configuration by invoking the NSX API PUT
|
|
/api/v1/global-configs/RoutingGlobalConfig with logical_uplink_mtu in the request body.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeature 3 }
|
|
|
|
vmwNsxTMTUCheckGlobalRouterMTUTooBigClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The global router MTU is less than the MTU of overlay Transport Zone now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeature 4 }
|
|
|
|
vmwNsxTMTUCheckMTUMismatchWithinTransportZone NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MTU configuration mismatch between Transport Nodes (ESXi, KVM and Edge) attached to the same Transport Zone.
|
|
MTU values on all switches attached to the same Transport Zone not being consistent will cause
|
|
connectivity issues.
|
|
|
|
Action required:
|
|
1. Navigate to System | Fabric | Settings | MTU Configuration Check | Inconsistent on the NSX UI to check
|
|
more mismatch details.
|
|
2. Set the same MTU value on all switches attached to the same Transport Zone
|
|
by invoking the NSX API PUT /api/v1/host-switch-profiles/<host-switch-profile-id>
|
|
with mtu in the request body, or API PUT /api/v1/global-configs/SwitchingGlobalConfig
|
|
with physical_uplink_mtu in request body.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeature 1 }
|
|
|
|
vmwNsxTMTUCheckMTUMismatchWithinTransportZoneClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All MTU values between Transport Nodes attached to the same Transport Zone are consistent now.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTMTUCheckFeature 2 }
|
|
|
|
-- **********************************************************
|
|
-- NAT feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNATFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NAT feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 46 }
|
|
|
|
vmwNsxTNATFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NAT feature notifications.
|
|
"
|
|
::= { vmwNsxTNATFeaturePrefix 0 }
|
|
|
|
vmwNsxTNATSNATPortUsageOnGatewayIsHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSNATIPAddress,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNAT ports usage on logical router vmwNsxTDataCenterEntityId for
|
|
SNAT IP vmwNsxTDataCenterSNATIPAddress has reached
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%. New flows will
|
|
not be SNATed when usage reaches the maximum limit.
|
|
|
|
Action required:
|
|
Log in as the admin user on Edge node and invoke the NSX CLI command
|
|
`get firewall <LR_INT_UUID> connection state` by using the right interface
|
|
uuid and check various SNAT mappings for the SNAT IP vmwNsxTDataCenterSNATIPAddress.
|
|
Check traffic flows going through the gateway is not a denial-of-service
|
|
attack or anomalous burst. If the traffic appears to be within
|
|
the normal load but the alarm threshold is hit, consider adding more
|
|
SNAT IP addresses to distribute the load or
|
|
route new traffic to another Edge node.
|
|
"
|
|
::= { vmwNsxTNATFeature 1 }
|
|
|
|
vmwNsxTNATSNATPortUsageOnGatewayIsHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSNATIPAddress,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNAT ports usage on logical router vmwNsxTDataCenterEntityId for SNAT IP vmwNsxTDataCenterSNATIPAddress
|
|
has reached below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNATFeature 2 }
|
|
|
|
-- **********************************************************
|
|
-- NCPHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNCPHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NCPHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 11 }
|
|
|
|
vmwNsxTNCPHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NCPHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTNCPHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTNCPHealthNCPPluginDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager Node has detected the NCP is down or unhealthy.
|
|
|
|
Action required:
|
|
To find the clusters which are having issues, use the NSX UI and
|
|
navigate to the Alarms page. The Entity name value for this alarm
|
|
instance identifies the cluster name. Or invoke the NSX API GET
|
|
/api/v1/systemhealth/container-cluster/ncp/status to fetch all
|
|
cluster statuses and determine the name of any clusters that report
|
|
DOWN or UNKNOWN. Then on the NSX UI Inventory | Container | Clusters
|
|
page find the cluster by name and click the Nodes tab which lists
|
|
all Kubernetes and PAS cluster members.
|
|
For Kubernetes cluster:
|
|
1. Check NCP Pod liveness by finding the K8s master node from all the
|
|
cluster members and log onto the master node. Then invoke the kubectl
|
|
command `kubectl get pods --all-namespaces`. If there is an issue with
|
|
the NCP Pod, use kubectl logs command to check the issue and fix the
|
|
error.
|
|
2. Check the connection between NCP and Kubernetes API server. The
|
|
NSX CLI can be used inside the NCP Pod to check this connection status
|
|
by invoking the following commands from the master VM.
|
|
`kubectl exec -it <NCP-Pod-Name> -n nsx-system bash`
|
|
`nsxcli`
|
|
`get ncp-k8s-api-server status`
|
|
If there is an issue with the connection, check both the network
|
|
and NCP configurations.
|
|
3. Check the connection between NCP and NSX Manager. The NSX CLI can be
|
|
used inside the NCP Pod to check this connection status by invoking the
|
|
following command from the master VM.
|
|
`kubectl exec -it <NCP-Pod-Name> -n nsx-system bash`
|
|
`nsxcli`
|
|
`get ncp-nsx status`
|
|
If there is an issue with the connection, check both the network
|
|
and NCP configurations.
|
|
For PAS cluster:
|
|
1. Check the network connections between virtual machines and fix any
|
|
network issues.
|
|
2. Check the status of both nodes and services and fix crashed nodes
|
|
or services. Invoke the command `bosh vms` and `bosh instances -p` to
|
|
check the status of nodes and services.
|
|
"
|
|
::= { vmwNsxTNCPHealthFeature 3 }
|
|
|
|
vmwNsxTNCPHealthNCPPluginDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Manager Node has detected the NCP is up or healthy again.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNCPHealthFeature 4 }
|
|
|
|
-- **********************************************************
|
|
-- NodeAgentsHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNodeAgentsHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NodeAgentsHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 12 }
|
|
|
|
vmwNsxTNodeAgentsHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NodeAgentsHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTNodeAgentsHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The agents running inside the Node VM appear to be down.
|
|
|
|
Action required:
|
|
For ESX:
|
|
1. If Vmk50 is missing, refer to this Knowledge Base article
|
|
https://kb.vmware.com/s/article/67432.
|
|
2. If Hyperbus 4094 is missing, restarting nsx-cfgagent or restarting the
|
|
container host VM may help.
|
|
3. If container host VIF is blocked, check the connection to the Controller
|
|
to make sure all configurations are sent down.
|
|
4. If nsx-cfg-agent has stopped, restart nsx-cfgagent.
|
|
For KVM:
|
|
1. If Hyperbus namespace is missing, restarting the nsx-opsagent may help
|
|
recreate the namespace.
|
|
2. If Hyperbus interface is missing inside the hyperbus namespace,
|
|
restarting the nsx-opsagent may help.
|
|
3. If nsx-agent has stopped, restart nsx-agent.
|
|
For Both ESX and KVM:
|
|
1. If the node-agent package is missing, check whether node-agent package
|
|
has been successfully installed in the container host vm.
|
|
2. If the interface for node-agent in container host vm is down, check the
|
|
eth1 interface status inside the container host vm.
|
|
"
|
|
::= { vmwNsxTNodeAgentsHealthFeature 3 }
|
|
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The agents inside the Node VM are running.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNodeAgentsHealthFeature 4 }
|
|
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The agents running inside the Node VM appear to be down on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
1. If Vmk50 on DPU vmwNsxTDataCenterDPUId is missing, refer to this Knowledge Base article
|
|
https://kb.vmware.com/s/article/67432.
|
|
2. If Hyperbus 4094 on DPU vmwNsxTDataCenterDPUId is missing, restarting nsx-cfgagent on DPU vmwNsxTDataCenterDPUId
|
|
or restarting the container host VM may help.
|
|
3. If container host VIF is blocked, check the connection to the Controller
|
|
to make sure all configurations are sent down.
|
|
4. If nsx-cfg-agent on DPU vmwNsxTDataCenterDPUId has stopped, restart nsx-cfgagent on DPU vmwNsxTDataCenterDPUId .
|
|
5. If the node-agent package is missing, check whether node-agent package
|
|
has been successfully installed in the container host vm.
|
|
6. If the interface for node-agent in container host vm is down, check the
|
|
eth1 interface status inside the container host vm.
|
|
"
|
|
::= { vmwNsxTNodeAgentsHealthFeature 5 }
|
|
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The agents inside the Node VM are running on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNodeAgentsHealthFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- NSXApplicationPlatformCommunication feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NSXApplicationPlatformCommunication feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 41 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NSXApplicationPlatformCommunication feature notifications.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeaturePrefix 0 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflow NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of pending messages in the messaging topic Over Flow is above the
|
|
pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
|
|
|
|
Action required:
|
|
Add nodes and then scale up the NSX Application Platform cluster. If bottleneck can be attributed to a specific service,
|
|
for example, the analytics service, then scale up the specific service when the new nodes are added.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 7 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of pending messages in the messaging topic Over Flow is below the pending
|
|
message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 8 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflow NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of pending messages in the messaging topic Raw Flow is above the
|
|
pending message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
|
|
|
|
Action required:
|
|
Add nodes and then scale up the NSX Application Platform cluster. If the bottleneck can be attributed to a specific service,
|
|
for example, the analytics service, then scale up the specific service when the new nodes are added.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 11 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of pending messages in the messaging topic Raw Flow is below the pending
|
|
message threshold of vmwNsxTDataCenterNappMessagingLAGThreshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 12 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnected NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is disconnected
|
|
from the NSX management cluster.
|
|
|
|
Action required:
|
|
Check whether the manager cluster certificate, manager node certificates,
|
|
kafka certificate and ingress certificate match on both NSX Manager and the
|
|
NSX Application Platform cluster. Check expiration dates of the above mentioned
|
|
certificates to make sure they are valid. Check the network connection between
|
|
NSX Manager and NSX Application Platform cluster and resolve any network connection failures.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 1 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is reconnected
|
|
to the NSX management cluster.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 2 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnected NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId is disconnected from
|
|
the NSX Application Platform cluster's messaging broker. Data collection is affected.
|
|
|
|
Action required:
|
|
Restart the messaging service if it is not running in the NSX Application
|
|
Platform cluster. Resolve the network connection failure between the Transport node
|
|
flow exporter and the NSX Application Platform cluster.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 13 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId has reconnected to
|
|
the NSX Application Platform cluster's messaging broker.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 14 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId DPU vmwNsxTDataCenterDPUId is disconnected
|
|
from the Intelligence node's messaging broker. Data collection is affected.
|
|
|
|
Action required:
|
|
Restart the messaging service if it is not running in the Intelligence
|
|
node. Resolve the network connection failure between the Transport node
|
|
flow exporter and the Intelligence node.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 17 }
|
|
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The flow exporter on Transport node vmwNsxTDataCenterEntityId DPU vmwNsxTDataCenterDPUId has reconnected
|
|
to the Intelligence node's messaging broker.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformCommunicationFeature 18 }
|
|
|
|
-- **********************************************************
|
|
-- NSXApplicationPlatformHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the NSXApplicationPlatformHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 43 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for NSXApplicationPlatformHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Analytics service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 1 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Analytics service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 2 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Analytics service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 3 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Analytics service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 4 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Analytics service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 5 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Analytics service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 6 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Analytics service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 7 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Analytics service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 8 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Analytics service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 9 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Analytics service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 10 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Analytics service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Analytics service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 11 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Analytics service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 12 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the System Load field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
computing power is required, click on the Scale Out button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 13 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 14 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the System Load field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
computing power is required, click on the Scale Out button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 15 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 16 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Storage field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
disk storage is required, click on the Scale Out button to request more resources.
|
|
If data storage service is under strain, another way is to click on the Scale Up button
|
|
to increase disk size.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 17 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 18 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Storage field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
disk storage is required, click on the Scale Out button to request more resources.
|
|
If data storage service is under strain, another way is to click on the Scale Up button
|
|
to increase disk size.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 19 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 20 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Memory field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
memory is required, click on the Scale Out button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 21 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 22 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Memory field of individual services to see
|
|
which service is under pressure. See if the load can be reduced. If more
|
|
memory is required, click on the Scale Out button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 23 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is
|
|
below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 24 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Configuration Database service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 31 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Configuration Database service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 32 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Configuration Database service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 33 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Configuration Database service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 34 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Configuration Database service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 35 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Configuration Database service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 36 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Configuration Database service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 37 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Configuration Database service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 38 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Configuration Database service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 109 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Configuration Database service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 110 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Configuration Database service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 39 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Configuration Database service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 40 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Data Storage service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Data Storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 41 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Data Storage service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 42 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Data Storage service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Data Storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 43 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Data Storage service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 44 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Data Storage service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out or scale up the data storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 45 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Data Storage service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 46 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Data Storage service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out or scale up the data storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 47 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Data Storage service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 48 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Data Storage service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Data Storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 49 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Data Storage service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 50 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Data Storage service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Data Storage service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 51 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Data Storage service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 52 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Messaging service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 53 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Messaging service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 54 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Messaging service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 55 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Messaging service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 56 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Messaging service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 57 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Messaging service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 58 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Messaging service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 59 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Messaging service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 60 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Messaging service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 61 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Messaging service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 62 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Messaging service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services or the Messaging service.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 63 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Messaging service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 64 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Metrics service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 97 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Metrics service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 98 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Metrics service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 99 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Metrics service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 100 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Metrics service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 101 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Metrics service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 102 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Metrics service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 103 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Metrics service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 104 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Metrics service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 105 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Metrics service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 106 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Metrics service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 107 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Metrics service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 108 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is degraded.
|
|
|
|
Action required:
|
|
Get more information from alarms of nodes and services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 117 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 118 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId overall status is down.
|
|
|
|
Action required:
|
|
Get more information from alarms of nodes and services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 119 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform cluster vmwNsxTDataCenterNappClusterId is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 120 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the System Load field of individual services to see
|
|
which service is under pressure. See if load can be reduced. If only a small minority
|
|
of the nodes have high CPU usage, by default, Kubernetes will reschedule services automatically.
|
|
If most nodes have high CPU usage and load cannot be reduced, click on the Scale Out
|
|
button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 65 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 66 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the System Load field of individual services to see
|
|
which service is under pressure. See if load can be reduced. If only a small minority
|
|
of the nodes have high CPU usage, by default, Kubernetes will reschedule services automatically.
|
|
If most nodes have high CPU usage and load cannot be reduced, click on the Scale Out
|
|
button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 67 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 68 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Storage field of individual services to see which service is
|
|
under pressure. Clean up unused data or log to free up disk resources
|
|
and see if the load can be reduced. If more disk storage is required, Scale Out the
|
|
service under pressure. If data storage service is under strain, another way is to
|
|
click on the Scale Up button to increase disk size.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 69 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below
|
|
the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 70 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is above
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Storage field of individual services to see
|
|
which service is under pressure. Clean up unused data or log to free up disk resources
|
|
and see if the load can be reduced. If more disk storage is required, Scale Out the
|
|
service under pressure. If data storage service is under strain, another way is to
|
|
click on the Scale Up button to increase disk size.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 71 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName is below
|
|
the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 72 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is above the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Memory field of individual services to see
|
|
which service is under pressure. See if load can be reduced. If only a small minority
|
|
of the nodes have high Memory usage, by default, Kubernetes will reschedule services automatically.
|
|
If most nodes have high Memory usage and load cannot be reduced, click on the Scale Out
|
|
button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 73 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is below the high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 74 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is above the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services
|
|
and check the Memory field of individual services to see
|
|
which service is under pressure. See if load can be reduced. If only a small minority
|
|
of the nodes have high Memory usage, by default, Kubernetes will reschedule services automatically.
|
|
If most nodes have high Memory usage and load cannot be reduced, click on the Scale Out
|
|
button to request more resources.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 75 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of NSX Application Platform node vmwNsxTDataCenterNappNodeName
|
|
is below the very high threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 76 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is degraded.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Resources to
|
|
check which node is degraded. Check network, memory and CPU usage of the node.
|
|
Reboot the node if it is a worker node.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 77 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 78 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is not running.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Resources to
|
|
check which node is down. Check network, memory and CPU usage of the node.
|
|
Reboot the node if it is a worker node.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 79 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"NSX Application Platform node vmwNsxTDataCenterNappNodeName is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 80 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Platform Services service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 81 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Platform Services service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 82 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Platform Services service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 83 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The CPU usage of Platform Services service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 84 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Platform Services service is above the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 85 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Platform Services service is below the high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 86 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Platform Services service is above the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Clean up files not needed.
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 87 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The disk usage of Platform Services service is below the very high
|
|
threshold value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 88 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Platform Services service is above the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 89 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Platform Services service is below the high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 90 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHi NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Platform Services service is above the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
Scale out all services.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 91 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSystemUsageThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The memory usage of Platform Services service is below the very high threshold
|
|
value of vmwNsxTDataCenterSystemUsageThreshold%.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 92 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterNappServiceName is degraded. The service may still be able to reach a quorum while
|
|
pods associated with vmwNsxTDataCenterNappServiceName are not all stable. Resources consumed by these
|
|
unstable pods may be released.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service
|
|
is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which
|
|
specific service is degraded and the reason behind it. Invoke the following CLI command to restart
|
|
the degraded service if necessary:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
Degraded services can function correctly but performance is sub-optimal.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 93 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterNappServiceName is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 94 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterNappServiceName is not running.
|
|
|
|
Action required:
|
|
In the NSX UI, navigate to System | NSX Application Platform | Core Services to check which service
|
|
is degraded. Invoke the NSX API GET /napp/api/v1/platform/monitor/feature/health to check which
|
|
specific service is down and the reason behind it. Invoke the following CLI command to restart
|
|
the degraded service:
|
|
`kubectl rollout restart <statefulset/deployment> <service_name> -n <namespace>`
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 95 }
|
|
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterNappServiceName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service vmwNsxTDataCenterNappServiceName is running properly.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTNSXApplicationPlatformHealthFeature 96 }
|
|
|
|
-- **********************************************************
|
|
-- PasswordManagement feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTPasswordManagementFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the PasswordManagement feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 4 }
|
|
|
|
vmwNsxTPasswordManagementFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for PasswordManagement feature notifications.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeaturePrefix 0 }
|
|
|
|
vmwNsxTPasswordManagementPasswordExpirationApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername,
|
|
vmwNsxTDataCenterPasswordExpirationDays
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for user vmwNsxTDataCenterUsername is approaching expiration in
|
|
vmwNsxTDataCenterPasswordExpirationDays days.
|
|
|
|
Action required:
|
|
The password for the user vmwNsxTDataCenterUsername needs to be changed soon. For example,
|
|
to apply a new password to a user, invoke the following NSX API with a valid
|
|
password in the request body: PUT /api/v1/node/users/<userid> where <userid>
|
|
is the ID of the user.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 1 }
|
|
|
|
vmwNsxTPasswordManagementPasswordExpirationApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for the user vmwNsxTDataCenterUsername has been changed successfully or
|
|
is no longer expired or the user is no longer active.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 2 }
|
|
|
|
vmwNsxTPasswordManagementPasswordExpired NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for user vmwNsxTDataCenterUsername has expired.
|
|
|
|
Action required:
|
|
The password for user vmwNsxTDataCenterUsername must be changed now to access the
|
|
system. For example, to apply a new password to a user, invoke the
|
|
following NSX API with a valid password in the request body: PUT
|
|
/api/v1/node/users/<userid> where <userid> is the ID of the user. If the
|
|
admin user (with <userid> 10000) password has expired, admin must login to
|
|
the system via SSH (if enabled) or console in order to change the password.
|
|
Upon entering the current expired password, admin will be prompted to enter
|
|
a new password.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 3 }
|
|
|
|
vmwNsxTPasswordManagementPasswordExpiredClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for user vmwNsxTDataCenterUsername has been changed successfully or
|
|
is no longer expired or the user is no longer active.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 4 }
|
|
|
|
vmwNsxTPasswordManagementPasswordIsAboutToExpire NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername,
|
|
vmwNsxTDataCenterPasswordExpirationDays
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for user vmwNsxTDataCenterUsername is about to expire in
|
|
vmwNsxTDataCenterPasswordExpirationDays days.
|
|
|
|
Action required:
|
|
Ensure the password for the user vmwNsxTDataCenterUsername is changed immediately. For
|
|
example, to apply a new password to a user, invoke the following NSX API
|
|
with a valid password in the request body: PUT /api/v1/node/users/<userid>
|
|
where <userid> is the ID of the user.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 5 }
|
|
|
|
vmwNsxTPasswordManagementPasswordIsAboutToExpireClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The password for the user vmwNsxTDataCenterUsername has been changed successfully or
|
|
is no longer expired or the user is no longer active.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPasswordManagementFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- PhysicalServer feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTPhysicalServerFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the PhysicalServer feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 47 }
|
|
|
|
vmwNsxTPhysicalServerFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for PhysicalServer feature notifications.
|
|
"
|
|
::= { vmwNsxTPhysicalServerFeaturePrefix 0 }
|
|
|
|
vmwNsxTPhysicalServerPhysicalServerInstallFailed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) installation failed.
|
|
|
|
Action required:
|
|
Navigate to System > Fabric > Nodes > Host Transport Nodes and resolve the error on the node.
|
|
"
|
|
::= { vmwNsxTPhysicalServerFeature 1 }
|
|
|
|
vmwNsxTPhysicalServerPhysicalServerInstallFailedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) installation completed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPhysicalServerFeature 2 }
|
|
|
|
vmwNsxTPhysicalServerPhysicalServerUninstallFailed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) uninstallation failed.
|
|
|
|
Action required:
|
|
Navigate to System > Fabric > Nodes > Host Transport Nodes and resolve the error on the node.
|
|
"
|
|
::= { vmwNsxTPhysicalServerFeature 3 }
|
|
|
|
vmwNsxTPhysicalServerPhysicalServerUninstallFailedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) uninstallation completed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPhysicalServerFeature 4 }
|
|
|
|
vmwNsxTPhysicalServerPhysicalServerUpgradeFailed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) upgrade failed.
|
|
|
|
Action required:
|
|
Navigate to System > Upgrade and resolve the error, then re-trigger the upgrade.
|
|
"
|
|
::= { vmwNsxTPhysicalServerFeature 5 }
|
|
|
|
vmwNsxTPhysicalServerPhysicalServerUpgradeFailedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Physical Server vmwNsxTDataCenterTransportNodeName (vmwNsxTDataCenterEntityId) upgrade completed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPhysicalServerFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- PolicyConstraint feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTPolicyConstraintFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the PolicyConstraint feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 53 }
|
|
|
|
vmwNsxTPolicyConstraintFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for PolicyConstraint feature notifications.
|
|
"
|
|
::= { vmwNsxTPolicyConstraintFeaturePrefix 0 }
|
|
|
|
vmwNsxTPolicyConstraintCreationCountLimitReached NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterConstraintType,
|
|
vmwNsxTDataCenterConstraintTypePath,
|
|
vmwNsxTDataCenterCurrentCount,
|
|
vmwNsxTDataCenterConstraintLimit
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Entity count for type vmwNsxTDataCenterConstraintType in vmwNsxTDataCenterConstraintTypePath is currently at vmwNsxTDataCenterCurrentCount which reached the maximum limit of vmwNsxTDataCenterConstraintLimit.
|
|
|
|
Action required:
|
|
Review vmwNsxTDataCenterConstraintType usage. Update the constraint to increase the limit or delete unused vmwNsxTDataCenterConstraintType.
|
|
"
|
|
::= { vmwNsxTPolicyConstraintFeature 1 }
|
|
|
|
vmwNsxTPolicyConstraintCreationCountLimitReachedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterConstraintType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"vmwNsxTDataCenterConstraintType Count is below threshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTPolicyConstraintFeature 2 }
|
|
|
|
-- **********************************************************
|
|
-- Routing feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTRoutingFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the Routing feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 28 }
|
|
|
|
vmwNsxTRoutingFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for Routing feature notifications.
|
|
"
|
|
::= { vmwNsxTRoutingFeaturePrefix 0 }
|
|
|
|
vmwNsxTRoutingBFDDownOnExternalInterface NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterPeerAddress,
|
|
vmwNsxTDataCenterSrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is down.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers`.
|
|
2. Switch to the service router vmwNsxTDataCenterSrId
|
|
3. Invoke the NSX CLI command `ping vmwNsxTDataCenterPeerAddress` to verify the
|
|
connectivity.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 7 }
|
|
|
|
vmwNsxTRoutingBFDDownOnExternalInterfaceClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterPeerAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In router vmwNsxTDataCenterLrId, BFD session for peer vmwNsxTDataCenterPeerAddress is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 8 }
|
|
|
|
vmwNsxTRoutingBGPDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterFailureReason,
|
|
vmwNsxTDataCenterSrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is down.
|
|
Reason: vmwNsxTDataCenterFailureReason.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers`.
|
|
2. Switch to service-router vmwNsxTDataCenterSrId.
|
|
If the reason indicates Network or config error -
|
|
3. Invoke the NSX CLI command `get bgp neighbor summary` to check the
|
|
BGP neighbor status.
|
|
If the reason indicates `Edge is not ready`, check why the Edge node is not in good state.
|
|
4. Invoke the NSX CLI command `get edge-cluster status` to check reason why Edge node might be down.
|
|
5. Invoke the NSX CLI commands `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
|
|
6. Check any Edge health related alarms to get more information.
|
|
Check /var/log/syslog to see if there are any errors related to BGP
|
|
connectivity.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 1 }
|
|
|
|
vmwNsxTRoutingBGPDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterBGPNeighborIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In Router vmwNsxTDataCenterLrId, BGP neighbor vmwNsxTDataCenterEntityId (vmwNsxTDataCenterBGPNeighborIP) is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 2 }
|
|
|
|
vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterPrefixesCountThreshold,
|
|
vmwNsxTDataCenterPrefixesCountMax
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP reaches vmwNsxTDataCenterPrefixesCountThreshold. Limit defined for this peer is vmwNsxTDataCenterPrefixesCountMax.
|
|
|
|
Action required:
|
|
1. Check the BGP routing policies in the external router.
|
|
2. Consider reducing the number of routes advertised by the BGP peer by applying routing policies and filters to the external router.
|
|
3. If required, increase the maximum prefixes settings under the BGP neighbor configuration section.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 39 }
|
|
|
|
vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterPrefixesCountThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCountThreshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 40 }
|
|
|
|
vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterPrefixesCountMax
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP exceeded the limit defined for this peer of vmwNsxTDataCenterPrefixesCountMax.
|
|
|
|
Action required:
|
|
1. Check the BGP routing policies in the external router.
|
|
2. Consider reducing the number of routes advertised by the BGP peer by applying routing policies and filters to the external router.
|
|
3. If required, increase the maximum prefixes settings under the BGP neighbor configuration section.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 41 }
|
|
|
|
vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterPrefixesCountMax
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IPv4 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCountMax.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 42 }
|
|
|
|
vmwNsxTRoutingMaximumIPv4RouteLimitApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterRouteLimitThreshold,
|
|
vmwNsxTDataCenterEdgeNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 routes limit has reached vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode.
|
|
|
|
Action required:
|
|
1. Check route redistribution policies and routes received from all external peers.
|
|
2. Consider reducing the number of routes by applying routing policies and filters accordingly.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 43 }
|
|
|
|
vmwNsxTRoutingMaximumIPv4RouteLimitApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterRouteLimitThreshold,
|
|
vmwNsxTDataCenterEdgeNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 routes are within the limit of vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 44 }
|
|
|
|
vmwNsxTRoutingMaximumIPv4RouteLimitExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterRouteLimitMaximum,
|
|
vmwNsxTDataCenterEdgeNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 routes has exceeded limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode.
|
|
|
|
Action required:
|
|
1. Check route redistribution policies and routes received from all external peers.
|
|
2. Consider reducing the number of routes by applying routing policies and filters accordingly.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 45 }
|
|
|
|
vmwNsxTRoutingMaximumIPv4RouteLimitExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterRouteLimitMaximum,
|
|
vmwNsxTDataCenterEdgeNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv4 routes are within the limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 46 }
|
|
|
|
vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterPrefixesCountThreshold,
|
|
vmwNsxTDataCenterPrefixesCountMax
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP reaches vmwNsxTDataCenterPrefixesCountThreshold. Limit defined for this peer is vmwNsxTDataCenterPrefixesCountMax.
|
|
|
|
Action required:
|
|
1. Check the BGP routing policies in the external router.
|
|
2. Consider reducing the number of routes advertised by the BGP peer by applying routing policies and filters to the external router.
|
|
3. If required, increase the maximum prefixes settings under the BGP neighbor configuration section.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 47 }
|
|
|
|
vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterPrefixesCountThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCountThreshold.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 48 }
|
|
|
|
vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterPrefixesCountMax
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP exceeded the limit defined for this peer of vmwNsxTDataCenterPrefixesCountMax.
|
|
|
|
Action required:
|
|
1. Check the BGP routing policies in the external router.
|
|
2. Consider reducing the number of routes advertised by the BGP peer by applying routing policies and filters to the external router.
|
|
3. If required, increase the maximum prefixes settings under the BGP neighbor configuration section.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 49 }
|
|
|
|
vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterPrefixesCountMax
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of IPv6 vmwNsxTDataCenterSubsequentAddressFamily prefixes received from vmwNsxTDataCenterBGPNeighborIP is within the limit vmwNsxTDataCenterPrefixesCountMax.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 50 }
|
|
|
|
vmwNsxTRoutingMaximumIPv6RouteLimitApproaching NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterRouteLimitThreshold,
|
|
vmwNsxTDataCenterEdgeNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv6 routes limit has reached vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode.
|
|
|
|
Action required:
|
|
1. Check route redistribution policies and routes received from all external peers.
|
|
2. Consider reducing the number of routes by applying routing policies and filters accordingly.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 51 }
|
|
|
|
vmwNsxTRoutingMaximumIPv6RouteLimitApproachingClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterRouteLimitThreshold,
|
|
vmwNsxTDataCenterEdgeNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv6 routes are within the limit of vmwNsxTDataCenterRouteLimitThreshold on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 52 }
|
|
|
|
vmwNsxTRoutingMaximumIPv6RouteLimitExceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterRouteLimitMaximum,
|
|
vmwNsxTDataCenterEdgeNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv6 routes has exceeded limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode.
|
|
|
|
Action required:
|
|
1. Check route redistribution policies and routes received from all external peers.
|
|
2. Consider reducing the number of routes by applying routing policies and filters accordingly.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 53 }
|
|
|
|
vmwNsxTRoutingMaximumIPv6RouteLimitExceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterRouteLimitMaximum,
|
|
vmwNsxTDataCenterEdgeNode
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IPv6 routes are within the limit of vmwNsxTDataCenterRouteLimitMaximum on Tier0 Gateway and all Tier0 VRFs on Edge node vmwNsxTDataCenterEdgeNode.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 54 }
|
|
|
|
vmwNsxTRoutingOSPFNeighborWentDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPeerAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OSPF neighbor vmwNsxTDataCenterPeerAddress moved from full to another state.
|
|
|
|
Action required:
|
|
1. Invoke the NSX CLI command `get logical-routers` to get the vrf id and
|
|
switch to TIER0 service router.
|
|
2. Run `get ospf neighbor` to check the current state of this neighbor. If the
|
|
neighbor is not listed in the output, the neighbor has gone down or out of
|
|
the network.
|
|
3. Invoke the NSX CLI command `ping <OSPF neighbor IP address>` to verify the
|
|
connectivity.
|
|
4. Also, verify the configuration for both NSX and peer router to ensure that
|
|
timers and area-id match.
|
|
5. Check /var/log/syslog to see if there are any errors related to connectivity.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 11 }
|
|
|
|
vmwNsxTRoutingOSPFNeighborWentDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterPeerAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"OSPF neighbor vmwNsxTDataCenterPeerAddress moved to full state.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 12 }
|
|
|
|
vmwNsxTRoutingProxyARPNotConfiguredForServiceIP NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceIP,
|
|
vmwNsxTDataCenterLrportId,
|
|
vmwNsxTDataCenterLrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Proxy ARP for Service IP vmwNsxTDataCenterServiceIP and Service entity vmwNsxTDataCenterEntityId
|
|
is not configured as the number of ARP proxy entries generated due to overlap of
|
|
the Service IP with subnet of lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId has exceeded
|
|
the allowed threshold limit of 16384.
|
|
|
|
Action required:
|
|
Reconfigure the Service IP vmwNsxTDataCenterServiceIP for the Service entity vmwNsxTDataCenterEntityId
|
|
or change the subnet of the lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId so that the proxy ARP entries
|
|
generated due to the overlap between the Service IP and the subnet of lrport is less than
|
|
the allowed threshold limit of 16384.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 13 }
|
|
|
|
vmwNsxTRoutingProxyARPNotConfiguredForServiceIPClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrportId,
|
|
vmwNsxTDataCenterLrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Proxy ARP for Service entity vmwNsxTDataCenterEntityId is generated successfully as the
|
|
overlap of service IP with subnet of lrport vmwNsxTDataCenterLrportId on Router vmwNsxTDataCenterLrId is
|
|
within the allowed limit of 16384 entries.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 14 }
|
|
|
|
vmwNsxTRoutingRoutingDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All BGP/BFD sessions are down.
|
|
|
|
Action required:
|
|
Invoke the NSX CLI command `get logical-routers` to get the tier0 service router
|
|
and switch to this vrf, then invoke the following NSX CLI commands.
|
|
1. `ping <BFD peer IP address>` to verify connectivity.
|
|
2. `get bfd-config` and `get bfd-sessions` to check if BFD is running well.
|
|
3. `get bgp neighbor summary` to check if BGP is running well.
|
|
Also check /var/log/syslog to see if there are any errors related to BGP
|
|
connectivity.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 9 }
|
|
|
|
vmwNsxTRoutingRoutingDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"At least one BGP/BFD session up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 10 }
|
|
|
|
vmwNsxTRoutingStaticRoutingRemoved NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterStaticAddress,
|
|
vmwNsxTDataCenterSrId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was removed because
|
|
BFD was down.
|
|
|
|
Action required:
|
|
The static routing entry was removed because the BFD session was down.
|
|
1. Invoke the NSX CLI command `get logical-routers`.
|
|
2. Switch to the service-router vmwNsxTDataCenterSrId.
|
|
3. Invoke the NSX CLI command `ping <BFD peer IP address>` to verify the
|
|
connectivity.
|
|
Also, verify the configuration in both NSX and the BFD peer to ensure that
|
|
timers have not been changed.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 5 }
|
|
|
|
vmwNsxTRoutingStaticRoutingRemovedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterStaticAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In router vmwNsxTDataCenterLrId, static route vmwNsxTDataCenterEntityId (vmwNsxTDataCenterStaticAddress) was re-added as BFD
|
|
recovered.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTRoutingFeature 6 }
|
|
|
|
-- **********************************************************
|
|
-- SecurityCompliance feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTSecurityComplianceFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the SecurityCompliance feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 56 }
|
|
|
|
vmwNsxTSecurityComplianceFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for SecurityCompliance feature notifications.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeaturePrefix 0 }
|
|
|
|
vmwNsxTSecurityCompliancePollEAL4NonCompliance NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One of the EAL4+ compliance requirements is being violated.
|
|
That means the NSX configuration is currently non-compliant with regards to EAL4+.
|
|
|
|
Action required:
|
|
Run the compliance report from the UI Home - Monitoring & Dashboard - Compliance Report menu
|
|
and resolve all the issues that are marked with the EAL4+ compliance name.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeature 1 }
|
|
|
|
vmwNsxTSecurityCompliancePollEAL4NonComplianceClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The EAL4+ compliance issues have all been resolved.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeature 2 }
|
|
|
|
vmwNsxTSecurityCompliancePollNDcPPNonCompliance NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One of the NDcPP compliance requirements is being violated.
|
|
That means the NSX configuration is currently non-compliant with regards to NDcPP.
|
|
|
|
Action required:
|
|
Run the compliance report from the UI Home - Monitoring & Dashboard - Compliance Report menu
|
|
and resolve all the issues that are marked with the NDcPP compliance name.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeature 3 }
|
|
|
|
vmwNsxTSecurityCompliancePollNDcPPNonComplianceClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NDcPP compliance issues have all been resolved.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeature 4 }
|
|
|
|
vmwNsxTSecurityComplianceTriggerEAL4NonCompliance NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One of the EAL4+ compliance requirements is being violated.
|
|
That means the NSX status is currently non-compliant with regards to EAL4+.
|
|
|
|
Action required:
|
|
Run the compliance report from the UI Home - Monitoring & Dashboard - Compliance Report menu
|
|
and resolve all the issues that are marked with the EAL4+ compliance name.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeature 5 }
|
|
|
|
vmwNsxTSecurityComplianceTriggerEAL4NonComplianceClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The EAL4+ compliance issues have all been resolved.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeature 6 }
|
|
|
|
vmwNsxTSecurityComplianceTriggerNDcPPNonCompliance NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One of the NDcPP compliance requirements is being violated.
|
|
That means the NSX status is currently non-compliant with regards to NDcPP.
|
|
|
|
Action required:
|
|
Run the compliance report from the UI Home - Monitoring & Dashboard - Compliance Report menu
|
|
and resolve all the issues that are marked with the NDcPP compliance name.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeature 7 }
|
|
|
|
vmwNsxTSecurityComplianceTriggerNDcPPNonComplianceClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The NDcPP compliance issues have all been resolved.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTSecurityComplianceFeature 8 }
|
|
|
|
-- **********************************************************
|
|
-- ServiceInsertion feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTServiceInsertionFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the ServiceInsertion feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 14 }
|
|
|
|
vmwNsxTServiceInsertionFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for ServiceInsertion feature notifications.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeaturePrefix 0 }
|
|
|
|
vmwNsxTServiceInsertionNewHostAdded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCentervCenterClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"New host added in cluster vmwNsxTDataCentervCenterClusterId and SVM will be deployed.
|
|
|
|
Action required:
|
|
Check for the VM deployment status and wait till it powers on.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 7 }
|
|
|
|
vmwNsxTServiceInsertionNewHostAddedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"New host added successfully.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 8 }
|
|
|
|
vmwNsxTServiceInsertionServiceChainPathDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service chain path is down on vmwNsxTDataCenterEntityId and traffic flow is impacted.
|
|
|
|
Action required:
|
|
Perform any corrective action from the KB and check if the status is up.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 21 }
|
|
|
|
vmwNsxTServiceInsertionServiceChainPathDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service chain path is up and configured as expected.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 22 }
|
|
|
|
vmwNsxTServiceInsertionServiceDeploymentFailed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCentervCenterClusterId,
|
|
vmwNsxTDataCenterFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has failed.
|
|
Reason : vmwNsxTDataCenterFailureReason
|
|
|
|
Action required:
|
|
Delete the service deployment using NSX UI or API.
|
|
Perform any corrective action from the KB and retry service deployment again.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 9 }
|
|
|
|
vmwNsxTServiceInsertionServiceDeploymentFailedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failed service deployment vmwNsxTDataCenterEntityId has been removed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 10 }
|
|
|
|
vmwNsxTServiceInsertionServiceDeploymentSucceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCentervCenterClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has succeeded.
|
|
|
|
Action required:
|
|
No action needed.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 11 }
|
|
|
|
vmwNsxTServiceInsertionServiceDeploymentSucceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCentervCenterClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The service deployment vmwNsxTDataCenterEntityId on cluster vmwNsxTDataCentervCenterClusterId has succeeded, no action needed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 12 }
|
|
|
|
vmwNsxTServiceInsertionServiceInsertionInfraStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPF not enabled at port level on host vmwNsxTDataCenterTransportNodeId and the status is down.
|
|
Reason : vmwNsxTDataCenterFailureReason.
|
|
|
|
Action required:
|
|
Perform any corrective action from the KB and check if the status is up.
|
|
Resolve the alarm manually after checking the status.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 29 }
|
|
|
|
vmwNsxTServiceInsertionServiceInsertionInfraStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Service insertion infrastructure status is up and has been correctly enabled on host.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 30 }
|
|
|
|
vmwNsxTServiceInsertionServiceUndeploymentFailed NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCentervCenterClusterId,
|
|
vmwNsxTDataCenterFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The deletion of service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has failed.
|
|
Reason : vmwNsxTDataCenterFailureReason
|
|
|
|
Action required:
|
|
Delete the service deployment using NSX UI or API.
|
|
Perform any corrective action from the KB and retry deleting the service deployment again.
|
|
Resolve the alarm manually after checking all the VM and objects are deleted.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 15 }
|
|
|
|
vmwNsxTServiceInsertionServiceUndeploymentFailedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The failed service deployment name vmwNsxTDataCenterEntityId has been removed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 16 }
|
|
|
|
vmwNsxTServiceInsertionServiceUndeploymentSucceeded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCentervCenterClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The deletion of service deployment vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName on cluster vmwNsxTDataCentervCenterClusterId has succeeded.
|
|
|
|
Action required:
|
|
No action needed.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 17 }
|
|
|
|
vmwNsxTServiceInsertionServiceUndeploymentSucceededClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCentervCenterClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The deletion of service deployment vmwNsxTDataCenterEntityId on cluster vmwNsxTDataCentervCenterClusterId has succeeded, no action needed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 18 }
|
|
|
|
vmwNsxTServiceInsertionSVMHealthStatusDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort,
|
|
vmwNsxTDataCenterFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The health check for SVM vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName is not working correctly on vmwNsxTDataCenterHostnameOrIPAddressWithPort.
|
|
Reason : vmwNsxTDataCenterFailureReason.
|
|
|
|
Action required:
|
|
Delete the service deployment using NSX UI or API.
|
|
Perform any corrective action from the KB and retry service deployment again if necessary.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 23 }
|
|
|
|
vmwNsxTServiceInsertionSVMHealthStatusDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SVM vmwNsxTDataCenterEntityId with wrong state has been removed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 24 }
|
|
|
|
vmwNsxTServiceInsertionSVMHealthStatusUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The health check for SVM vmwNsxTDataCenterEntityId for service vmwNsxTDataCenterServiceName is working correctly on vmwNsxTDataCenterHostnameOrIPAddressWithPort.
|
|
|
|
Action required:
|
|
No action needed.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 25 }
|
|
|
|
vmwNsxTServiceInsertionSVMHealthStatusUpClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SVM vmwNsxTDataCenterEntityId is working correctly, no action needed.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 26 }
|
|
|
|
vmwNsxTServiceInsertionSVMLivenessStateDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SVM liveness state is down on vmwNsxTDataCenterEntityId and traffic flow is impacted.
|
|
|
|
Action required:
|
|
Perform any corrective action from the KB and check if the state is up.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 27 }
|
|
|
|
vmwNsxTServiceInsertionSVMLivenessStateDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SVM liveness state is up and configured as expected.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTServiceInsertionFeature 28 }
|
|
|
|
-- **********************************************************
|
|
-- TEPHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTTEPHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the TEPHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 51 }
|
|
|
|
vmwNsxTTEPHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for TEPHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTTEPHealthFaultyTEP NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterVtepFaultReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId.
|
|
Overlay workloads using this TEP will face network outage.
|
|
Reason: vmwNsxTDataCenterVtepFaultReason.
|
|
|
|
Action required:
|
|
1. Check if TEP has valid IP or any other underlay connectivity issues.
|
|
2. Enable TEP HA to failover workloads to other healthy TEPs.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 1 }
|
|
|
|
vmwNsxTTEPHealthFaultyTEPClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is healthy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 2 }
|
|
|
|
vmwNsxTTEPHealthFaultyTEPOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterVtepFaultReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId.
|
|
Overlay workloads using this TEP will face network outage.
|
|
Reason: vmwNsxTDataCenterVtepFaultReason.
|
|
|
|
Action required:
|
|
1. Check if TEP has valid IP or any other underlay connectivity issues.
|
|
2. Enable TEP HA to failover workloads to other healthy TEPs.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 3 }
|
|
|
|
vmwNsxTTEPHealthFaultyTEPOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId is healthy.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 4 }
|
|
|
|
vmwNsxTTEPHealthTEPAutorecoverFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId failed.
|
|
Overlay workloads using this TEP will failover to other healthy TEPs.
|
|
If no other healthy TEPs, overlay workloads will face network outage.
|
|
|
|
Action required:
|
|
Check if TEP has valid IP or any other underlay connectivity issues.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 5 }
|
|
|
|
vmwNsxTTEPHealthTEPAutorecoverFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 6 }
|
|
|
|
vmwNsxTTEPHealthTEPAutorecoverFailureOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId failed.
|
|
Overlay workloads using this TEP will failover to other healthy TEPs.
|
|
If no other healthy TEPs, overlay workloads will face network outage.
|
|
|
|
Action required:
|
|
Check if TEP has valid IP or any other underlay connectivity issues.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 7 }
|
|
|
|
vmwNsxTTEPHealthTEPAutorecoverFailureOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId is cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 8 }
|
|
|
|
vmwNsxTTEPHealthTEPAutorecoverSuccess NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is successful.
|
|
|
|
Action required:
|
|
None.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 9 }
|
|
|
|
vmwNsxTTEPHealthTEPAutorecoverSuccessClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId is cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 10 }
|
|
|
|
vmwNsxTTEPHealthTEPAutorecoverSuccessOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId.
|
|
on DPU vmwNsxTDataCenterDPUId is successful.
|
|
|
|
Action required:
|
|
None.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 11 }
|
|
|
|
vmwNsxTTEPHealthTEPAutorecoverSuccessOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Auto Recover for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId.
|
|
on DPU vmwNsxTDataCenterDPUId is cleared.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 12 }
|
|
|
|
vmwNsxTTEPHealthTEPHaActivated NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TEP HA activated for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId.
|
|
|
|
Action required:
|
|
Enable AutoRecover or invoke Manual Recover for TEP:vmwNsxTDataCenterVtepName on VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 13 }
|
|
|
|
vmwNsxTTEPHealthTEPHaActivatedClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TEP HA cleared for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 14 }
|
|
|
|
vmwNsxTTEPHealthTEPHaActivatedOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TEP HA activated for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
Enable AutoRecover or invoke Manual Recover for TEP:vmwNsxTDataCenterVtepName on VDS:vmwNsxTDataCenterDvsName.
|
|
at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 15 }
|
|
|
|
vmwNsxTTEPHealthTEPHaActivatedOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterVtepName,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterTransportNodeId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TEP HA cleared for TEP:vmwNsxTDataCenterVtepName of VDS:vmwNsxTDataCenterDvsName at Transport node:vmwNsxTDataCenterTransportNodeId on DPU vmwNsxTDataCenterDPUId.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTEPHealthFeature 16 }
|
|
|
|
-- **********************************************************
|
|
-- TransportNodeHealth feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTTransportNodeHealthFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the TransportNodeHealth feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 18 }
|
|
|
|
vmwNsxTTransportNodeHealthFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for TransportNodeHealth feature notifications.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeaturePrefix 0 }
|
|
|
|
vmwNsxTTransportNodeHealthLAGMemberDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LACP reporting member down.
|
|
|
|
Action required:
|
|
Check the connection status of LAG members on hosts.
|
|
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
|
|
Host Transport Nodes.
|
|
2. In the Host Transport Nodes list, check the Node Status column. Find the
|
|
Transport node with the degraded or down Node Status.
|
|
3. Select <transport node> | Monitor. Find the bond(uplink) which is
|
|
reporting degraded or down.
|
|
4. Check the LACP member status details by logging into the failed host and
|
|
invoking `esxcli network vswitch dvs vmware lacp status get` on an ESXi
|
|
host or `ovs-appctl bond/show` and `ovs-appctl lacp/show` on a KVM host.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 5 }
|
|
|
|
vmwNsxTTransportNodeHealthLAGMemberDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LACP reporting member up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 6 }
|
|
|
|
vmwNsxTTransportNodeHealthLAGMemberDownOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LACP on DPU vmwNsxTDataCenterDPUId reporting member down.
|
|
|
|
Action required:
|
|
Check the connection status of LAG members on DPU vmwNsxTDataCenterDPUId.
|
|
Find out the mapped name of related physical NIC on host, then perform checking on UI.
|
|
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
|
|
Host Transport Nodes.
|
|
2. In the Host Transport Nodes list, check the Node Status column. Find the
|
|
Transport node with the degraded or down Node Status.
|
|
3. Select <transport node> | Monitor. Find the bond(uplink) which is
|
|
reporting degraded or down.
|
|
4. Check the LACP member status details by logging into the failed DPU vmwNsxTDataCenterDPUId and
|
|
invoking `esxcli network vswitch dvs vmware lacp status get`.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 9 }
|
|
|
|
vmwNsxTTransportNodeHealthLAGMemberDownOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"LACP on DPU vmwNsxTDataCenterDPUId reporting member up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 10 }
|
|
|
|
vmwNsxTTransportNodeHealthNVDSUplinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink is going down.
|
|
|
|
Action required:
|
|
Check the physical NICs' status of uplinks on hosts.
|
|
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
|
|
Host Transport Nodes.
|
|
2. In the Host Transport Nodes list, check the Node Status column. Find the
|
|
Transport node with the degraded or down Node Status.
|
|
3. Select <transport node> | Monitor. Check the status details of the
|
|
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
|
|
ensure all uplink interfaces are connected and up regardless of whether they
|
|
are in use or not.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 3 }
|
|
|
|
vmwNsxTTransportNodeHealthNVDSUplinkDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink is going up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 4 }
|
|
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink is going down.
|
|
|
|
Action required:
|
|
Check the physical NICs' status of uplinks on hosts.
|
|
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
|
|
Host Transport Nodes.
|
|
2. In the Host Transport Nodes list, check the Node Status column. Find the
|
|
Transport node with the degraded or down Node Status.
|
|
3. Select <transport node> | Monitor. Check the status details of the
|
|
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
|
|
ensure all uplink interfaces are connected and up regardless of whether they
|
|
are in use or not.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 7 }
|
|
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink is going up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 8 }
|
|
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink on DPU vmwNsxTDataCenterDPUId is going down.
|
|
|
|
Action required:
|
|
Check the physical NICs' status of uplinks on DPU vmwNsxTDataCenterDPUId.
|
|
Find out the mapped name of this physical NIC on host, then perform checking on UI.
|
|
1. In the NSX UI navigate to Fabric | Nodes | Transport Nodes |
|
|
Host Transport Nodes.
|
|
2. In the Host Transport Nodes list, check the Node Status column. Find the
|
|
Transport node with the degraded or down Node Status.
|
|
3. Select <transport node> | Monitor. Check the status details of the
|
|
bond(uplink) which is reporting degraded or down. To avoid a degraded state,
|
|
ensure all uplink interfaces are connected and up regardless of whether they
|
|
are in use or not.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 11 }
|
|
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPUClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterDPUId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Uplink on DPU vmwNsxTDataCenterDPUId is going up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTTransportNodeHealthFeature 12 }
|
|
|
|
-- **********************************************************
|
|
-- VMCApp feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTVMCAppFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the VMCApp feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 50 }
|
|
|
|
vmwNsxTVMCAppFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for VMCApp feature notifications.
|
|
"
|
|
::= { vmwNsxTVMCAppFeaturePrefix 0 }
|
|
|
|
vmwNsxTVMCAppTransitConnectFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transit Connect related configuration is not
|
|
fully correctly realized. Possible issues could be
|
|
failing to retrieve provider information or some
|
|
transient provider communication error.
|
|
|
|
Action required:
|
|
If this alarm is not auto-resolved within 10
|
|
minutes, retry the most recent transit connect
|
|
related request(s). For example, if a TGW
|
|
attachment API request triggered this alarm,
|
|
retry the TGW attachment API request again.
|
|
If alarm does not resolve even after retry, then try the following steps:
|
|
1. Check if the task keeps failing, or the task has recovered.
|
|
a) Identify leader Manager node.
|
|
After logging into one of the nodes, run command:
|
|
- `su admin`
|
|
- `get cluster status verbose`
|
|
This will show the leader Manager node
|
|
b) Log in to NSX leader Manager node.
|
|
check vmc-app.log on the NSX leader Manager node:
|
|
- `tail -f /var/log/policy/vmc-app.log`
|
|
c) Check logs for following prints
|
|
- If any of these error messages keeps showing every two mins, that means task keeps failing.
|
|
- Failed to get TGW route table for []. Error: []
|
|
- Failed to get TGW routes for attachment [] in route table []. Error
|
|
- Failed to get TGW attachment VPC ID for []. Error: []
|
|
- Failed to get TGW attachment resource ID for []. Error: Unknown resource type
|
|
- Failed to get TGW attachments for TGW []. Error: []
|
|
- Failed to get local TGW attachment []. Error: []
|
|
- Failed to find correct TgwAttachment state in AWS, state: [], skipping TGW route update task
|
|
- TGW attachment [] is not associated with any route table
|
|
- No local TGW SDDC attachment found for []
|
|
2. Check if all AWS calls from NSX Manager failed, on leader Manager node.
|
|
Run following command:
|
|
- `export HTTP_PROXY=http://<pop ip>:3128`
|
|
- `export HTTPS_PROXY=http://<pop ip>:3128`
|
|
- `export NO_PROXY=169.254.169.254`
|
|
- `aws ec2 describe-instances --region <region>`
|
|
If aws command failed with error, then there might be a system issue in HTTP
|
|
reverse proxy configuration on pop, or there is AWS service side issue.
|
|
3. Check whether TGW attachment still exists in AWS.
|
|
a) TGW attachment ID could be found with GET cloud-service/api/v1/infra/associated-groups
|
|
- `aws ec2 describe-transit-gateway-attachments --region <region> --transit-gateway-attachment-id <TGW attachment ID>`
|
|
If TGW attachment has been deleted, contact VMware Support, share SDDC ID and TGW attachment ID.
|
|
After VMware support team identified the issue, manually delete the object left behind, if needed.
|
|
b) Check if this TGW attachment exists on AWS console.
|
|
c) Another option is logging in to NSX Manager, using aws command to check the state of TGW attachment:
|
|
- `aws ec2 describe-transit-gateway-attachments --region <region> --transit-gateway-attachment-id <TGW attachment ID>`
|
|
"
|
|
::= { vmwNsxTVMCAppFeature 1 }
|
|
|
|
vmwNsxTVMCAppTransitConnectFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Transit Connect failure is remediated.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVMCAppFeature 2 }
|
|
|
|
-- **********************************************************
|
|
-- VPN feature event notifications
|
|
-- **********************************************************
|
|
|
|
vmwNsxTVPNFeaturePrefix OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Notifications applicable to the VPN feature have this OID prefix."
|
|
::= { vmwNsxTDataCenterNotifications 15 }
|
|
|
|
vmwNsxTVPNFeature OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sub-identifier added to ensure the next-to-last sub-identifier is zero
|
|
for VPN feature notifications.
|
|
"
|
|
::= { vmwNsxTVPNFeaturePrefix 0 }
|
|
|
|
vmwNsxTVPNIPsecPolicyBasedSessionDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSessionDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The policy based IPsec VPN session vmwNsxTDataCenterEntityId is down.
|
|
Reason: vmwNsxTDataCenterSessionDownReason.
|
|
|
|
Action required:
|
|
Check IPsec VPN session configuration and resolve errors based on the
|
|
session down reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 7 }
|
|
|
|
vmwNsxTVPNIPsecPolicyBasedSessionDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The policy based IPsec VPN session vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 8 }
|
|
|
|
vmwNsxTVPNIPsecPolicyBasedTunnelDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"One or more policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are down.
|
|
|
|
Action required:
|
|
Check IPsec VPN session configuration and resolve errors based on the
|
|
tunnel down reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 9 }
|
|
|
|
vmwNsxTVPNIPsecPolicyBasedTunnelDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All policy based IPsec VPN tunnels in session vmwNsxTDataCenterEntityId are up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 10 }
|
|
|
|
vmwNsxTVPNIPsecRouteBasedSessionDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterSessionDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The route based IPsec VPN session vmwNsxTDataCenterEntityId is down.
|
|
Reason: vmwNsxTDataCenterSessionDownReason.
|
|
|
|
Action required:
|
|
Check IPsec VPN session configuration and resolve errors based on the
|
|
session down reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 11 }
|
|
|
|
vmwNsxTVPNIPsecRouteBasedSessionDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The route based IPsec VPN session vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 12 }
|
|
|
|
vmwNsxTVPNIPsecRouteBasedTunnelDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterTunnelDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is down.
|
|
Reason: vmwNsxTDataCenterTunnelDownReason.
|
|
|
|
Action required:
|
|
Check IPsec VPN session configuration and resolve errors based on the
|
|
tunnel down reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 13 }
|
|
|
|
vmwNsxTVPNIPsecRouteBasedTunnelDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The route based IPsec VPN tunnel in session vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 14 }
|
|
|
|
vmwNsxTVPNIPsecServiceDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterServiceDownReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPsec service vmwNsxTDataCenterEntityId is down. Reason: vmwNsxTDataCenterServiceDownReason.
|
|
|
|
Action required:
|
|
1. Disable and enable the IPsec service from NSX Manager UI.
|
|
2. If the issue still persists, check syslog for error logs and contact
|
|
VMware support.
|
|
"
|
|
::= { vmwNsxTVPNFeature 17 }
|
|
|
|
vmwNsxTVPNIPsecServiceDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The IPsec service vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 18 }
|
|
|
|
vmwNsxTVPNL2VpnSessionDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The L2VPN session vmwNsxTDataCenterEntityId is down.
|
|
|
|
Action required:
|
|
Check L2VPN session status for session down reason and resolve errors based
|
|
on the reason.
|
|
"
|
|
::= { vmwNsxTVPNFeature 15 }
|
|
|
|
vmwNsxTVPNL2VpnSessionDownClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterEntityId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The L2VPN session vmwNsxTDataCenterEntityId is up.
|
|
|
|
Action required:
|
|
None, receipt of this notification indicates event cleared.
|
|
"
|
|
::= { vmwNsxTVPNFeature 16 }
|
|
|
|
-- **********************************************************
|
|
-- Conformance information
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDataCenterConformance OBJECT IDENTIFIER ::= { vmwNSXsysMIB 2 }
|
|
vmwNsxTDataCenterCompliances OBJECT IDENTIFIER ::= { vmwNsxTDataCenterConformance 1 }
|
|
vmwNsxTDataCenterSMIBGroups OBJECT IDENTIFIER ::= { vmwNsxTDataCenterConformance 2 }
|
|
|
|
-- **********************************************************
|
|
-- Compliance statements
|
|
-- **********************************************************
|
|
|
|
vmwNsxTDataCenterBasicCompliance MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationGroup
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 1 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterTimestamp,
|
|
vmwNsxTDataCenterFeatureName,
|
|
vmwNsxTDataCenterEventType,
|
|
vmwNsxTDataCenterEventSeverity,
|
|
vmwNsxTDataCenterNodeId,
|
|
vmwNsxTDataCenterNodeType,
|
|
vmwNsxTDataCenterApplianceAddress,
|
|
vmwNsxTDataCenterBGPNeighborIP,
|
|
vmwNsxTDataCenterCurrentGatewayState,
|
|
vmwNsxTDataCenterCurrentServiceState,
|
|
vmwNsxTDataCenterDHCPPoolUsage,
|
|
vmwNsxTDataCenterDHCPServerId,
|
|
vmwNsxTDataCenterDatapathResourceUsage,
|
|
vmwNsxTDataCenterDiskPartitionName,
|
|
vmwNsxTDataCenterDuplicateIPAddress,
|
|
vmwNsxTDataCenterEdgeNICName,
|
|
vmwNsxTDataCenterEdgeServiceName,
|
|
vmwNsxTDataCenterEntityId,
|
|
vmwNsxTDataCenterEventId,
|
|
vmwNsxTDataCenterFailureReason,
|
|
vmwNsxTDataCenterHeapType,
|
|
vmwNsxTDataCenterIntelligenceNodeId,
|
|
vmwNsxTDataCenterLicenseEditionType,
|
|
vmwNsxTDataCenterMempoolName,
|
|
vmwNsxTDataCenterPasswordExpirationDays,
|
|
vmwNsxTDataCenterPeerAddress,
|
|
vmwNsxTDataCenterPreviousGatewayState,
|
|
vmwNsxTDataCenterPreviousServiceState,
|
|
vmwNsxTDataCenterRxRingBufferOverflowPercentage,
|
|
vmwNsxTDataCenterServiceName,
|
|
vmwNsxTDataCenterSessionDownReason,
|
|
vmwNsxTDataCenterSrId,
|
|
vmwNsxTDataCenterStaticAddress,
|
|
vmwNsxTDataCenterSystemResourceUsage,
|
|
vmwNsxTDataCenterSystemUsageThreshold,
|
|
vmwNsxTDataCenterTunnelDownReason,
|
|
vmwNsxTDataCenterTxRingBufferOverflowPercentage,
|
|
vmwNsxTDataCenterUsername
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 1 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTAlarmManagementAlarmServiceOverloaded,
|
|
vmwNsxTAlarmManagementAlarmServiceOverloadedClear,
|
|
vmwNsxTAlarmManagementHeavyVolumeOfAlarms,
|
|
vmwNsxTAlarmManagementHeavyVolumeOfAlarmsClear,
|
|
vmwNsxTCertificatesCertificateExpirationApproaching,
|
|
vmwNsxTCertificatesCertificateExpirationApproachingClear,
|
|
vmwNsxTCertificatesCertificateExpired,
|
|
vmwNsxTCertificatesCertificateExpiredClear,
|
|
vmwNsxTCertificatesCertificateIsAboutToExpire,
|
|
vmwNsxTCertificatesCertificateIsAboutToExpireClear,
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDown,
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDownClear,
|
|
vmwNsxTDHCPPoolLeaseAllocationFailed,
|
|
vmwNsxTDHCPPoolLeaseAllocationFailedClear,
|
|
vmwNsxTDHCPPoolOverloaded,
|
|
vmwNsxTDHCPPoolOverloadedClear,
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHigh,
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighClear,
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHigh,
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighClear,
|
|
vmwNsxTDNSForwarderDisabled,
|
|
vmwNsxTDNSForwarderDisabledClear,
|
|
vmwNsxTDNSForwarderDown,
|
|
vmwNsxTDNSForwarderDownClear,
|
|
vmwNsxTEdgeHealthEdgeCPUUsageHigh,
|
|
vmwNsxTEdgeHealthEdgeCPUUsageHighClear,
|
|
vmwNsxTEdgeHealthEdgeCPUUsageVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeCPUUsageVeryHighClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailure,
|
|
vmwNsxTEdgeHealthEdgeDatapathConfigurationFailureClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUHighClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathCPUVeryHighClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDown,
|
|
vmwNsxTEdgeHealthEdgeDatapathCryptodrvDownClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathMempoolHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathMempoolHighClear,
|
|
vmwNsxTEdgeHealthEdgeDiskUsageHigh,
|
|
vmwNsxTEdgeHealthEdgeDiskUsageHighClear,
|
|
vmwNsxTEdgeHealthEdgeDiskUsageVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeDiskUsageVeryHighClear,
|
|
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHigh,
|
|
vmwNsxTEdgeHealthEdgeGlobalARPTableUsageHighClear,
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageHigh,
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageHighClear,
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeMemoryUsageVeryHighClear,
|
|
vmwNsxTEdgeHealthEdgeNICLinkStatusDown,
|
|
vmwNsxTEdgeHealthEdgeNICLinkStatusDownClear,
|
|
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBuffer,
|
|
vmwNsxTEdgeHealthEdgeNICOutOfReceiveBufferClear,
|
|
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBuffer,
|
|
vmwNsxTEdgeHealthEdgeNICOutOfTransmitBufferClear,
|
|
vmwNsxTEndpointProtectionEAMStatusDown,
|
|
vmwNsxTEndpointProtectionEAMStatusDownClear,
|
|
vmwNsxTEndpointProtectionPartnerChannelDown,
|
|
vmwNsxTEndpointProtectionPartnerChannelDownClear,
|
|
vmwNsxTHighAvailabilityTier0GatewayFailover,
|
|
vmwNsxTHighAvailabilityTier0GatewayFailoverClear,
|
|
vmwNsxTHighAvailabilityTier1GatewayFailover,
|
|
vmwNsxTHighAvailabilityTier1GatewayFailoverClear,
|
|
vmwNsxTInfrastructureCommunicationEdgeTunnelsDown,
|
|
vmwNsxTInfrastructureCommunicationEdgeTunnelsDownClear,
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusChanged,
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusChangedClear,
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusDown,
|
|
vmwNsxTInfrastructureServiceEdgeServiceStatusDownClear,
|
|
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnected,
|
|
vmwNsxTIntelligenceCommunicationTNFlowExporterDisconnectedClear,
|
|
vmwNsxTIntelligenceHealthCPUUsageHigh,
|
|
vmwNsxTIntelligenceHealthCPUUsageHighClear,
|
|
vmwNsxTIntelligenceHealthCPUUsageVeryHigh,
|
|
vmwNsxTIntelligenceHealthCPUUsageVeryHighClear,
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHigh,
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageHighClear,
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHigh,
|
|
vmwNsxTIntelligenceHealthDataDiskPartitionUsageVeryHighClear,
|
|
vmwNsxTIntelligenceHealthDiskUsageHigh,
|
|
vmwNsxTIntelligenceHealthDiskUsageHighClear,
|
|
vmwNsxTIntelligenceHealthDiskUsageVeryHigh,
|
|
vmwNsxTIntelligenceHealthDiskUsageVeryHighClear,
|
|
vmwNsxTIntelligenceHealthMemoryUsageHigh,
|
|
vmwNsxTIntelligenceHealthMemoryUsageHighClear,
|
|
vmwNsxTIntelligenceHealthMemoryUsageVeryHigh,
|
|
vmwNsxTIntelligenceHealthMemoryUsageVeryHighClear,
|
|
vmwNsxTIntelligenceHealthNodeStatusDegraded,
|
|
vmwNsxTIntelligenceHealthNodeStatusDegradedClear,
|
|
vmwNsxTLicensesLicenseExpired,
|
|
vmwNsxTLicensesLicenseExpiredClear,
|
|
vmwNsxTLicensesLicenseIsAboutToExpire,
|
|
vmwNsxTLicensesLicenseIsAboutToExpireClear,
|
|
vmwNsxTLoadBalancerLBCPUVeryHigh,
|
|
vmwNsxTLoadBalancerLBCPUVeryHighClear,
|
|
vmwNsxTLoadBalancerLBStatusDown,
|
|
vmwNsxTLoadBalancerLBStatusDownClear,
|
|
vmwNsxTLoadBalancerPoolStatusDown,
|
|
vmwNsxTLoadBalancerPoolStatusDownClear,
|
|
vmwNsxTLoadBalancerVirtualServerStatusDown,
|
|
vmwNsxTLoadBalancerVirtualServerStatusDownClear,
|
|
vmwNsxTManagerHealthDuplicateIPAddress,
|
|
vmwNsxTManagerHealthDuplicateIPAddressClear,
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageHigh,
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageHighClear,
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHigh,
|
|
vmwNsxTManagerHealthManagerConfigDiskUsageVeryHighClear,
|
|
vmwNsxTManagerHealthManagerCPUUsageHigh,
|
|
vmwNsxTManagerHealthManagerCPUUsageHighClear,
|
|
vmwNsxTManagerHealthManagerCPUUsageVeryHigh,
|
|
vmwNsxTManagerHealthManagerCPUUsageVeryHighClear,
|
|
vmwNsxTManagerHealthManagerDiskUsageHigh,
|
|
vmwNsxTManagerHealthManagerDiskUsageHighClear,
|
|
vmwNsxTManagerHealthManagerDiskUsageVeryHigh,
|
|
vmwNsxTManagerHealthManagerDiskUsageVeryHighClear,
|
|
vmwNsxTManagerHealthManagerMemoryUsageHigh,
|
|
vmwNsxTManagerHealthManagerMemoryUsageHighClear,
|
|
vmwNsxTManagerHealthManagerMemoryUsageVeryHigh,
|
|
vmwNsxTManagerHealthManagerMemoryUsageVeryHighClear,
|
|
vmwNsxTNCPHealthNCPPluginDown,
|
|
vmwNsxTNCPHealthNCPPluginDownClear,
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDown,
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDownClear,
|
|
vmwNsxTPasswordManagementPasswordExpirationApproaching,
|
|
vmwNsxTPasswordManagementPasswordExpirationApproachingClear,
|
|
vmwNsxTPasswordManagementPasswordExpired,
|
|
vmwNsxTPasswordManagementPasswordExpiredClear,
|
|
vmwNsxTPasswordManagementPasswordIsAboutToExpire,
|
|
vmwNsxTPasswordManagementPasswordIsAboutToExpireClear,
|
|
vmwNsxTRoutingBFDDownOnExternalInterface,
|
|
vmwNsxTRoutingBFDDownOnExternalInterfaceClear,
|
|
vmwNsxTRoutingBGPDown,
|
|
vmwNsxTRoutingBGPDownClear,
|
|
vmwNsxTRoutingRoutingDown,
|
|
vmwNsxTRoutingRoutingDownClear,
|
|
vmwNsxTRoutingStaticRoutingRemoved,
|
|
vmwNsxTRoutingStaticRoutingRemovedClear,
|
|
vmwNsxTTransportNodeHealthLAGMemberDown,
|
|
vmwNsxTTransportNodeHealthLAGMemberDownClear,
|
|
vmwNsxTTransportNodeHealthNVDSUplinkDown,
|
|
vmwNsxTTransportNodeHealthNVDSUplinkDownClear,
|
|
vmwNsxTVPNIPsecPolicyBasedSessionDown,
|
|
vmwNsxTVPNIPsecPolicyBasedSessionDownClear,
|
|
vmwNsxTVPNIPsecPolicyBasedTunnelDown,
|
|
vmwNsxTVPNIPsecPolicyBasedTunnelDownClear,
|
|
vmwNsxTVPNIPsecRouteBasedSessionDown,
|
|
vmwNsxTVPNIPsecRouteBasedSessionDownClear,
|
|
vmwNsxTVPNIPsecRouteBasedTunnelDown,
|
|
vmwNsxTVPNIPsecRouteBasedTunnelDownClear,
|
|
vmwNsxTVPNL2VpnSessionDown,
|
|
vmwNsxTVPNL2VpnSessionDownClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 2 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance2 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 2 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup2 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterBGPSourceIP,
|
|
vmwNsxTDataCenterRemoteSiteId,
|
|
vmwNsxTDataCenterRemoteSiteName,
|
|
vmwNsxTDataCenterSiteId,
|
|
vmwNsxTDataCenterSiteName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 3 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup2 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTEdgeHealthStorageError,
|
|
vmwNsxTEdgeHealthStorageErrorClear,
|
|
vmwNsxTFederationLmToLmSynchronizationError,
|
|
vmwNsxTFederationLmToLmSynchronizationErrorClear,
|
|
vmwNsxTFederationLmToLmSynchronizationWarning,
|
|
vmwNsxTFederationLmToLmSynchronizationWarningClear,
|
|
vmwNsxTFederationRtepBGPDown,
|
|
vmwNsxTFederationRtepBGPDownClear,
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageHigh,
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageHighClear,
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHigh,
|
|
vmwNsxTManagerHealthOperationsDbDiskUsageVeryHighClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 4 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance3 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 3 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup3 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterLrId,
|
|
vmwNsxTDataCenterManagerNodeName,
|
|
vmwNsxTDataCenterRxMisses,
|
|
vmwNsxTDataCenterRxProcessed,
|
|
vmwNsxTDataCenterTransportNodeAddress,
|
|
vmwNsxTDataCenterTransportNodeName,
|
|
vmwNsxTDataCenterTxMisses,
|
|
vmwNsxTDataCenterTxProcessed
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 5 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup3 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDown,
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownClear,
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownLg,
|
|
vmwNsxTCommunicationManagementChannelToTransportNodeDownLgClear,
|
|
vmwNsxTCommunicationManagerControlChannelDown,
|
|
vmwNsxTCommunicationManagerControlChannelDownClear,
|
|
vmwNsxTFederationRtepConnectivityLost,
|
|
vmwNsxTFederationRtepConnectivityLostClear,
|
|
vmwNsxTManagerHealthStorageError,
|
|
vmwNsxTManagerHealthStorageErrorClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 6 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance4 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 4 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup4 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterActiveGlobalManager,
|
|
vmwNsxTDataCenterActiveGlobalManagers,
|
|
vmwNsxTDataCenterApplianceFQDN,
|
|
vmwNsxTDataCenterCapacityDisplayName,
|
|
vmwNsxTDataCenterCapacityUsageCount,
|
|
vmwNsxTDataCenterCentralControlPlaneId,
|
|
vmwNsxTDataCenterDirectoryDomain,
|
|
vmwNsxTDataCenterDisplayedLicenseKey,
|
|
vmwNsxTDataCenterEdgeThreadName,
|
|
vmwNsxTDataCenterHostnameOrIPAddressWithPort,
|
|
vmwNsxTDataCenterIDSEventsCount,
|
|
vmwNsxTDataCenterLDAPServer,
|
|
vmwNsxTDataCenterLatencySource,
|
|
vmwNsxTDataCenterLatencyThreshold,
|
|
vmwNsxTDataCenterLatencyValue,
|
|
vmwNsxTDataCenterManagerNodeId,
|
|
vmwNsxTDataCenterMaxCapacityThreshold,
|
|
vmwNsxTDataCenterMaxIDSEventsAllowed,
|
|
vmwNsxTDataCenterMaxSupportedCapacityCount,
|
|
vmwNsxTDataCenterMinCapacityThreshold,
|
|
vmwNsxTDataCenterRemoteApplianceAddress,
|
|
vmwNsxTDataCenterRemoteManagerNodeId,
|
|
vmwNsxTDataCenterTimeoutInMinutes
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 7 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup4 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTAuditLogHealthAuditLogFileUpdateError,
|
|
vmwNsxTAuditLogHealthAuditLogFileUpdateErrorClear,
|
|
vmwNsxTAuditLogHealthRemoteLoggingServerError,
|
|
vmwNsxTAuditLogHealthRemoteLoggingServerErrorClear,
|
|
vmwNsxTCapacityMaximumCapacity,
|
|
vmwNsxTCapacityMaximumCapacityClear,
|
|
vmwNsxTCapacityMaximumCapacityThreshold,
|
|
vmwNsxTCapacityMaximumCapacityThresholdClear,
|
|
vmwNsxTCapacityMinimumCapacityThreshold,
|
|
vmwNsxTCapacityMinimumCapacityThresholdClear,
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDown,
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownClear,
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLong,
|
|
vmwNsxTCommunicationControlChannelToManagerNodeDownTooLongClear,
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDown,
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownClear,
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownLong,
|
|
vmwNsxTCommunicationControlChannelToTransportNodeDownLongClear,
|
|
vmwNsxTCommunicationManagerClusterLatencyHigh,
|
|
vmwNsxTCommunicationManagerClusterLatencyHighClear,
|
|
vmwNsxTCommunicationManagerFQDNLookupFailure,
|
|
vmwNsxTCommunicationManagerFQDNLookupFailureClear,
|
|
vmwNsxTCommunicationManagerFQDNReverseLookupFailure,
|
|
vmwNsxTCommunicationManagerFQDNReverseLookupFailureClear,
|
|
vmwNsxTDistributedIDSIPSMaxEventsReached,
|
|
vmwNsxTDistributedIDSIPSMaxEventsReachedClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageMediumHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineCPUUsageVeryHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDown,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageMediumHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHigh,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageVeryHighClear,
|
|
vmwNsxTEdgeHealthDatapathThreadDeadlocked,
|
|
vmwNsxTEdgeHealthDatapathThreadDeadlockedClear,
|
|
vmwNsxTFederationGMToGMSplitBrain,
|
|
vmwNsxTFederationGMToGMSplitBrainClear,
|
|
vmwNsxTIdentityFirewallConnectivityToLDAPServerLost,
|
|
vmwNsxTIdentityFirewallConnectivityToLDAPServerLostClear,
|
|
vmwNsxTIdentityFirewallErrorInDeltaSync,
|
|
vmwNsxTIdentityFirewallErrorInDeltaSyncClear,
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknown,
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknownClear,
|
|
vmwNsxTIntelligenceHealthStorageLatencyHigh,
|
|
vmwNsxTIntelligenceHealthStorageLatencyHighClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 8 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance5 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 5 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup5 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTRoutingOSPFNeighborWentDown,
|
|
vmwNsxTRoutingOSPFNeighborWentDownClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 10 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance6 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 6 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup6 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterLrportId,
|
|
vmwNsxTDataCenterServiceIP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 11 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup6 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTRoutingProxyARPNotConfiguredForServiceIP,
|
|
vmwNsxTRoutingProxyARPNotConfiguredForServiceIPClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 12 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance7 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 7 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup7 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterIntentPath
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 13 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup7 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTIPAMIPBlockUsageVeryHigh,
|
|
vmwNsxTIPAMIPBlockUsageVeryHighClear,
|
|
vmwNsxTIPAMIPPoolUsageVeryHigh,
|
|
vmwNsxTIPAMIPPoolUsageVeryHighClear,
|
|
vmwNsxTLoadBalancerDLBStatusDown,
|
|
vmwNsxTLoadBalancerDLBStatusDownClear,
|
|
vmwNsxTLoadBalancerLBEdgeCapacityInUseHigh,
|
|
vmwNsxTLoadBalancerLBEdgeCapacityInUseHighClear,
|
|
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHigh,
|
|
vmwNsxTLoadBalancerLBPoolMemberCapacityInUseVeryHighClear,
|
|
vmwNsxTLoadBalancerLBStatusDegraded,
|
|
vmwNsxTLoadBalancerLBStatusDegradedClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 14 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance8 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 8 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup8 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterDNSId,
|
|
vmwNsxTDataCenterDNSUpstreamIP,
|
|
vmwNsxTDataCenterFirewallHalfopenFlowUsage,
|
|
vmwNsxTDataCenterFirewallICMPFlowUsage,
|
|
vmwNsxTDataCenterFirewallIPFlowUsage,
|
|
vmwNsxTDataCenterFirewallUDPFlowUsage
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 15 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup8 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTDNSForwarderUpstreamServerTimeout,
|
|
vmwNsxTDNSForwarderUpstreamServerTimeoutClear,
|
|
vmwNsxTGatewayFirewallICMPFlowCountExceeded,
|
|
vmwNsxTGatewayFirewallICMPFlowCountExceededClear,
|
|
vmwNsxTGatewayFirewallICMPFlowCountHigh,
|
|
vmwNsxTGatewayFirewallICMPFlowCountHighClear,
|
|
vmwNsxTGatewayFirewallIPFlowCountExceeded,
|
|
vmwNsxTGatewayFirewallIPFlowCountExceededClear,
|
|
vmwNsxTGatewayFirewallIPFlowCountHigh,
|
|
vmwNsxTGatewayFirewallIPFlowCountHighClear,
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceeded,
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountExceededClear,
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHigh,
|
|
vmwNsxTGatewayFirewallTcpHalfOpenFlowCountHighClear,
|
|
vmwNsxTGatewayFirewallUDPFlowCountExceeded,
|
|
vmwNsxTGatewayFirewallUDPFlowCountExceededClear,
|
|
vmwNsxTGatewayFirewallUDPFlowCountHigh,
|
|
vmwNsxTGatewayFirewallUDPFlowCountHighClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 16 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance9 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationInfoGroup9,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8,
|
|
vmwNsxTDataCenterNotificationGroup9
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 9 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup9 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterAPICollectionPath,
|
|
vmwNsxTDataCenterCABundleAgeThreshold,
|
|
vmwNsxTDataCenterEdgeCryptoDrvName,
|
|
vmwNsxTDataCenterEdgeNodeSettingMismatchReason,
|
|
vmwNsxTDataCenterEdgeNodeAndvSphereSettingsMismatchReason,
|
|
vmwNsxTDataCenterEdgeVMvSphereSettingsMismatchReason,
|
|
vmwNsxTDataCenterEdgevSphereLocationMismatchReason,
|
|
vmwNsxTDataCenterFirewallSNATPortsUsage,
|
|
vmwNsxTDataCenterFlowIdentifier,
|
|
vmwNsxTDataCenterFromGMPath,
|
|
vmwNsxTDataCenterGroupType,
|
|
vmwNsxTDataCenterManagerNodeIDS,
|
|
vmwNsxTDataCenterNICThroughput,
|
|
vmwNsxTDataCenterNICThroughputThreshold,
|
|
vmwNsxTDataCenterNappClusterId,
|
|
vmwNsxTDataCenterNappMessagingLAGThreshold,
|
|
vmwNsxTDataCenterNappNodeId,
|
|
vmwNsxTDataCenterNappNodeName,
|
|
vmwNsxTDataCenterNappServiceName,
|
|
vmwNsxTDataCenterQueueName,
|
|
vmwNsxTDataCenterQueueSize,
|
|
vmwNsxTDataCenterQueueSizeThreshold,
|
|
vmwNsxTDataCenterSNATIPAddress,
|
|
vmwNsxTDataCenterServiceDownReason,
|
|
vmwNsxTDataCenterServiceRouterId,
|
|
vmwNsxTDataCenterSyncIssueReason,
|
|
vmwNsxTDataCenterToGMPath,
|
|
vmwNsxTDataCenterTransportNodeId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 17 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup9 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTCertificatesCABundleUpdateRecommended,
|
|
vmwNsxTCertificatesCABundleUpdateRecommendedClear,
|
|
vmwNsxTCertificatesCABundleUpdateSuggested,
|
|
vmwNsxTCertificatesCABundleUpdateSuggestedClear,
|
|
vmwNsxTClusteringClusterDegraded,
|
|
vmwNsxTClusteringClusterDegradedClear,
|
|
vmwNsxTClusteringClusterUnavailable,
|
|
vmwNsxTClusteringClusterUnavailableClear,
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDown,
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownClear,
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownLong,
|
|
vmwNsxTCommunicationManagementChannelToManagerNodeDownLongClear,
|
|
vmwNsxTDistributedFirewallDFWSessionCountHigh,
|
|
vmwNsxTDistributedFirewallDFWSessionCountHighClear,
|
|
vmwNsxTDistributedFirewallDFWVmotionFailure,
|
|
vmwNsxTDistributedFirewallDFWVmotionFailureClear,
|
|
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChanged,
|
|
vmwNsxTEdgeEdgeNodeSettingsAndvSphereSettingsAreChangedClear,
|
|
vmwNsxTEdgeEdgeNodeSettingsMismatch,
|
|
vmwNsxTEdgeEdgeNodeSettingsMismatchClear,
|
|
vmwNsxTEdgeEdgeVmvSphereSettingsMismatch,
|
|
vmwNsxTEdgeEdgeVmvSphereSettingsMismatchClear,
|
|
vmwNsxTEdgeEdgevSphereLocationMismatch,
|
|
vmwNsxTEdgeEdgevSphereLocationMismatchClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputHighClear,
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHigh,
|
|
vmwNsxTEdgeHealthEdgeDatapathNICThroughputVeryHighClear,
|
|
vmwNsxTEdgeHealthFailureDomainDown,
|
|
vmwNsxTEdgeHealthFailureDomainDownClear,
|
|
vmwNsxTFederationGMToGMLatencyWarning,
|
|
vmwNsxTFederationGMToGMLatencyWarningClear,
|
|
vmwNsxTFederationGMToGMSynchronizationError,
|
|
vmwNsxTFederationGMToGMSynchronizationErrorClear,
|
|
vmwNsxTFederationGMToGMSynchronizationWarning,
|
|
vmwNsxTFederationGMToGMSynchronizationWarningClear,
|
|
vmwNsxTFederationGMToLMLatencyWarning,
|
|
vmwNsxTFederationGMToLMLatencyWarningClear,
|
|
vmwNsxTFederationGMToLMSynchronizationError,
|
|
vmwNsxTFederationGMToLMSynchronizationErrorClear,
|
|
vmwNsxTFederationGMToLMSynchronizationWarning,
|
|
vmwNsxTFederationGMToLMSynchronizationWarningClear,
|
|
vmwNsxTFederationLMRestoreWhileConfigImportInProgress,
|
|
vmwNsxTFederationLMRestoreWhileConfigImportInProgressClear,
|
|
vmwNsxTFederationQueueOccupancyThresholdExceeded,
|
|
vmwNsxTFederationQueueOccupancyThresholdExceededClear,
|
|
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemory,
|
|
vmwNsxTLoadBalancerConfigurationNotRealizedDueToLowMemoryClear,
|
|
vmwNsxTMTUCheckGlobalRouterMTUTooBig,
|
|
vmwNsxTMTUCheckGlobalRouterMTUTooBigClear,
|
|
vmwNsxTMTUCheckMTUMismatchWithinTransportZone,
|
|
vmwNsxTMTUCheckMTUMismatchWithinTransportZoneClear,
|
|
vmwNsxTNATSNATPortUsageOnGatewayIsHigh,
|
|
vmwNsxTNATSNATPortUsageOnGatewayIsHighClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflow,
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInOverflowClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflow,
|
|
vmwNsxTNSXApplicationPlatformCommunicationDelayInRawflowClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnected,
|
|
vmwNsxTNSXApplicationPlatformCommunicationMgrDisconnectedClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnected,
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectedClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsCPUUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthAnalyticsMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterCPUUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterDiskUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthClusterMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHi,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbCPUUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthConfigDbMemUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreCPUUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthDatastoreMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingCPUUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMessagingMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsCPUUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsDiskUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHi,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUasgeHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthMetricsMemUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDegraded,
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDegradedClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDown,
|
|
vmwNsxTNSXApplicationPlatformHealthNappStatusDownClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeCPUUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeDiskUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeMemoryUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegraded,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDegradedClear,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDown,
|
|
vmwNsxTNSXApplicationPlatformHealthNodeStatusDownClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformCPUUsageVeryHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformDiskUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHigh,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemoryUsageHighClear,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHi,
|
|
vmwNsxTNSXApplicationPlatformHealthPlatformMemUsageVeryHiClear,
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegraded,
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDegradedClear,
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDown,
|
|
vmwNsxTNSXApplicationPlatformHealthServiceStatusDownClear,
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDown,
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDownClear,
|
|
vmwNsxTVPNIPsecServiceDown,
|
|
vmwNsxTVPNIPsecServiceDownClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 18 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance10 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationInfoGroup9,
|
|
vmwNsxTDataCenterNotificationInfoGroup10,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8,
|
|
vmwNsxTDataCenterNotificationGroup9,
|
|
vmwNsxTDataCenterNotificationGroup10
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 10 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup10 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterNewVMMorefId,
|
|
vmwNsxTDataCenterPolicyEdgeVMName,
|
|
vmwNsxTDataCenterVMMorefId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 19 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup10 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenter,
|
|
vmwNsxTEdgeEdgeVMNotPresentInBothNSXInventoryAndvCenterClear,
|
|
vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenter,
|
|
vmwNsxTEdgeEdgeVMPresentInNSXInventoryNotPresentInvCenterClear,
|
|
vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeploy,
|
|
vmwNsxTEdgeFailedToDeleteTheOldVMInvCenterDuringRedeployClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 20 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance11 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationInfoGroup9,
|
|
vmwNsxTDataCenterNotificationInfoGroup10,
|
|
vmwNsxTDataCenterNotificationInfoGroup11,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8,
|
|
vmwNsxTDataCenterNotificationGroup9,
|
|
vmwNsxTDataCenterNotificationGroup10,
|
|
vmwNsxTDataCenterNotificationGroup11
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 11 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup11 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterCoreId,
|
|
vmwNsxTDataCenterFlowCacheThreshold
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 21 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup11 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTEdgeHealthMegaFlowCacheHitRateLow,
|
|
vmwNsxTEdgeHealthMegaFlowCacheHitRateLowClear,
|
|
vmwNsxTEdgeHealthMicroFlowCacheHitRateLow,
|
|
vmwNsxTEdgeHealthMicroFlowCacheHitRateLowClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 22 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance12 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationInfoGroup9,
|
|
vmwNsxTDataCenterNotificationInfoGroup10,
|
|
vmwNsxTDataCenterNotificationInfoGroup11,
|
|
vmwNsxTDataCenterNotificationInfoGroup12,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8,
|
|
vmwNsxTDataCenterNotificationGroup9,
|
|
vmwNsxTDataCenterNotificationGroup10,
|
|
vmwNsxTDataCenterNotificationGroup11,
|
|
vmwNsxTDataCenterNotificationGroup12
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 12 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup12 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterCoreDumpCount,
|
|
vmwNsxTDataCenterDPUId,
|
|
vmwNsxTDataCenterEdgeClusterId,
|
|
vmwNsxTDataCenterEdgeNode,
|
|
vmwNsxTDataCenterMemberIndexId,
|
|
vmwNsxTDataCenterMpsServiceName,
|
|
vmwNsxTDataCenterNSXESXTNName,
|
|
vmwNsxTDataCenterNSXEdgeTNName,
|
|
vmwNsxTDataCenterNodeDisplayOrHostName,
|
|
vmwNsxTDataCenterPrefixesCountMax,
|
|
vmwNsxTDataCenterPrefixesCountThreshold,
|
|
vmwNsxTDataCenterRouteLimitMaximum,
|
|
vmwNsxTDataCenterRouteLimitThreshold,
|
|
vmwNsxTDataCenterSubsequentAddressFamily,
|
|
vmwNsxTDataCentervCenterClusterId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 23 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup12 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDownOnDPU,
|
|
vmwNsxTCniHealthHyperbusManagerConnectionDownOnDPUClear,
|
|
vmwNsxTCommunicationNetworkLatencyHigh,
|
|
vmwNsxTCommunicationNetworkLatencyHighClear,
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPU,
|
|
vmwNsxTDistributedFirewallDFWCPUUsageVeryHighOnDPUClear,
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPU,
|
|
vmwNsxTDistributedFirewallDFWMemoryUsageVeryHighOnDPUClear,
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproaching,
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPerHostApproachingClear,
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceeded,
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPerHostExceededClear,
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproaching,
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPervNICApproachingClear,
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceeded,
|
|
vmwNsxTDistributedFirewallDFWRulesLimitPervNICExceededClear,
|
|
vmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribed,
|
|
vmwNsxTDistributedIDSIPSIDPSBypassedCPUOversubscribedClear,
|
|
vmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribed,
|
|
vmwNsxTDistributedIDSIPSIDPSBypassedNetworkOversubscribedClear,
|
|
vmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHigh,
|
|
vmwNsxTDistributedIDSIPSIDPSEngineCPUOversubscriptionHighClear,
|
|
vmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHigh,
|
|
vmwNsxTDistributedIDSIPSIDPSCPUOversubscriptionVeryHighClear,
|
|
vmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribed,
|
|
vmwNsxTDistributedIDSIPSIDPSDroppedCPUOversubscribedClear,
|
|
vmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribed,
|
|
vmwNsxTDistributedIDSIPSIDPSDroppedNetworkOversubscribedClear,
|
|
vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHigh,
|
|
vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionHighClear,
|
|
vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHigh,
|
|
vmwNsxTDistributedIDSIPSIDPSNetworkOversubscriptionVeryHighClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPU,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineDownOnDPUClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPU,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemoryUsageHighOnDPUClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPU,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageMedHighOnDPUClear,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPU,
|
|
vmwNsxTDistributedIDSIPSNSXIDPSEngineMemUsageVeryHighDPUClear,
|
|
vmwNsxTEdgeClusterEdgeClusterMemberRelocateFailure,
|
|
vmwNsxTEdgeClusterEdgeClusterMemberRelocateFailureClear,
|
|
vmwNsxTInfrastructureServiceApplicationCrashed,
|
|
vmwNsxTInfrastructureServiceApplicationCrashedClear,
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknownOnDPU,
|
|
vmwNsxTInfrastructureServiceServiceStatusUnknownOnDPUClear,
|
|
vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachable,
|
|
vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachableClear,
|
|
vmwNsxTMalwarePreventionHealthDatabaseUnreachable,
|
|
vmwNsxTMalwarePreventionHealthDatabaseUnreachableClear,
|
|
vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachable,
|
|
vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachableClear,
|
|
vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachable,
|
|
vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachableClear,
|
|
vmwNsxTMalwarePreventionHealthServiceStatusDown,
|
|
vmwNsxTMalwarePreventionHealthServiceStatusDownClear,
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPU,
|
|
vmwNsxTNodeAgentsHealthNodeAgentsDownOnDPUClear,
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPU,
|
|
vmwNsxTNSXApplicationPlatformCommunicationExpDisconnectDPUClear,
|
|
vmwNsxTPhysicalServerPhysicalServerInstallFailed,
|
|
vmwNsxTPhysicalServerPhysicalServerInstallFailedClear,
|
|
vmwNsxTPhysicalServerPhysicalServerUninstallFailed,
|
|
vmwNsxTPhysicalServerPhysicalServerUninstallFailedClear,
|
|
vmwNsxTPhysicalServerPhysicalServerUpgradeFailed,
|
|
vmwNsxTPhysicalServerPhysicalServerUpgradeFailedClear,
|
|
vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproaching,
|
|
vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborApproachingClear,
|
|
vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceeded,
|
|
vmwNsxTRoutingMaximumIPv4PrefixesFromBGPNeighborExceededClear,
|
|
vmwNsxTRoutingMaximumIPv4RouteLimitApproaching,
|
|
vmwNsxTRoutingMaximumIPv4RouteLimitApproachingClear,
|
|
vmwNsxTRoutingMaximumIPv4RouteLimitExceeded,
|
|
vmwNsxTRoutingMaximumIPv4RouteLimitExceededClear,
|
|
vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproaching,
|
|
vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborApproachingClear,
|
|
vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceeded,
|
|
vmwNsxTRoutingMaximumIPv6PrefixesFromBGPNeighborExceededClear,
|
|
vmwNsxTRoutingMaximumIPv6RouteLimitApproaching,
|
|
vmwNsxTRoutingMaximumIPv6RouteLimitApproachingClear,
|
|
vmwNsxTRoutingMaximumIPv6RouteLimitExceeded,
|
|
vmwNsxTRoutingMaximumIPv6RouteLimitExceededClear,
|
|
vmwNsxTServiceInsertionNewHostAdded,
|
|
vmwNsxTServiceInsertionNewHostAddedClear,
|
|
vmwNsxTServiceInsertionServiceChainPathDown,
|
|
vmwNsxTServiceInsertionServiceChainPathDownClear,
|
|
vmwNsxTServiceInsertionServiceDeploymentFailed,
|
|
vmwNsxTServiceInsertionServiceDeploymentFailedClear,
|
|
vmwNsxTServiceInsertionServiceDeploymentSucceeded,
|
|
vmwNsxTServiceInsertionServiceDeploymentSucceededClear,
|
|
vmwNsxTServiceInsertionServiceInsertionInfraStatusDown,
|
|
vmwNsxTServiceInsertionServiceInsertionInfraStatusDownClear,
|
|
vmwNsxTServiceInsertionServiceUndeploymentFailed,
|
|
vmwNsxTServiceInsertionServiceUndeploymentFailedClear,
|
|
vmwNsxTServiceInsertionServiceUndeploymentSucceeded,
|
|
vmwNsxTServiceInsertionServiceUndeploymentSucceededClear,
|
|
vmwNsxTServiceInsertionSVMHealthStatusDown,
|
|
vmwNsxTServiceInsertionSVMHealthStatusDownClear,
|
|
vmwNsxTServiceInsertionSVMHealthStatusUp,
|
|
vmwNsxTServiceInsertionSVMHealthStatusUpClear,
|
|
vmwNsxTServiceInsertionSVMLivenessStateDown,
|
|
vmwNsxTServiceInsertionSVMLivenessStateDownClear,
|
|
vmwNsxTTransportNodeHealthLAGMemberDownOnDPU,
|
|
vmwNsxTTransportNodeHealthLAGMemberDownOnDPUClear,
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPU,
|
|
vmwNsxTTransportNodeHealthTransportNodeUplinkDownOnDPUClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 24 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance13 MODULE-COMPLIANCE
|
|
STATUS deprecated
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationInfoGroup9,
|
|
vmwNsxTDataCenterNotificationInfoGroup10,
|
|
vmwNsxTDataCenterNotificationInfoGroup11,
|
|
vmwNsxTDataCenterNotificationInfoGroup12,
|
|
vmwNsxTDataCenterNotificationInfoGroup13,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8,
|
|
vmwNsxTDataCenterNotificationGroup9,
|
|
vmwNsxTDataCenterNotificationGroup10,
|
|
vmwNsxTDataCenterNotificationGroup11,
|
|
vmwNsxTDataCenterNotificationGroup12,
|
|
vmwNsxTDataCenterNotificationGroup13
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 13 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup13 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterCollectorIP,
|
|
vmwNsxTDataCenterDvsAlias,
|
|
vmwNsxTDataCenterEdgeClusterHighestHwVersion,
|
|
vmwNsxTDataCenterEdgeClusterName,
|
|
vmwNsxTDataCenterEdgeTNHwVersion,
|
|
vmwNsxTDataCenterHaState,
|
|
vmwNsxTDataCenterHaState2,
|
|
vmwNsxTDataCenterStackAlias,
|
|
vmwNsxTDataCenterTransportNodeId2,
|
|
vmwNsxTDataCenterVerticalName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 25 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup13 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTCommunicationLimitedReachabilityOnDPU,
|
|
vmwNsxTCommunicationLimitedReachabilityOnDPUClear,
|
|
vmwNsxTCommunicationUnreachableCollectorOnDPU,
|
|
vmwNsxTCommunicationUnreachableCollectorOnDPUClear,
|
|
vmwNsxTEdgeEdgeHardwareVersionMismatch,
|
|
vmwNsxTEdgeEdgeHardwareVersionMismatchClear,
|
|
vmwNsxTHighAvailabilityTier0ServiceGroupFailover,
|
|
vmwNsxTHighAvailabilityTier0ServiceGroupFailoverClear,
|
|
vmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancy,
|
|
vmwNsxTHighAvailabilityTier0ServiceGroupReducedRedundancyClear,
|
|
vmwNsxTHighAvailabilityTier1ServiceGroupFailover,
|
|
vmwNsxTHighAvailabilityTier1ServiceGroupFailoverClear,
|
|
vmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancy,
|
|
vmwNsxTHighAvailabilityTier1ServiceGroupReducedRedundancyClear,
|
|
vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachable,
|
|
vmwNsxTMalwarePreventionHealthAnalystAPIServiceUnreachableClear,
|
|
vmwNsxTMalwarePreventionHealthDatabaseUnreachable,
|
|
vmwNsxTMalwarePreventionHealthDatabaseUnreachableClear,
|
|
vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachable,
|
|
vmwNsxTMalwarePreventionHealthFileExtractSvcUnreachableClear,
|
|
vmwNsxTMalwarePreventionHealthServiceStatusDown,
|
|
vmwNsxTMalwarePreventionHealthServiceStatusDownClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 26 }
|
|
|
|
vmwNsxTDataCenterBasicCompliance14 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for entities which implement VMWARE-NSX-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
vmwNsxTDataCenterNotificationInfoGroup,
|
|
vmwNsxTDataCenterNotificationInfoGroup2,
|
|
vmwNsxTDataCenterNotificationInfoGroup3,
|
|
vmwNsxTDataCenterNotificationInfoGroup4,
|
|
vmwNsxTDataCenterNotificationInfoGroup6,
|
|
vmwNsxTDataCenterNotificationInfoGroup7,
|
|
vmwNsxTDataCenterNotificationInfoGroup8,
|
|
vmwNsxTDataCenterNotificationInfoGroup9,
|
|
vmwNsxTDataCenterNotificationInfoGroup10,
|
|
vmwNsxTDataCenterNotificationInfoGroup11,
|
|
vmwNsxTDataCenterNotificationInfoGroup12,
|
|
vmwNsxTDataCenterNotificationInfoGroup13,
|
|
vmwNsxTDataCenterNotificationInfoGroup14,
|
|
vmwNsxTDataCenterNotificationGroup,
|
|
vmwNsxTDataCenterNotificationGroup2,
|
|
vmwNsxTDataCenterNotificationGroup3,
|
|
vmwNsxTDataCenterNotificationGroup4,
|
|
vmwNsxTDataCenterNotificationGroup5,
|
|
vmwNsxTDataCenterNotificationGroup6,
|
|
vmwNsxTDataCenterNotificationGroup7,
|
|
vmwNsxTDataCenterNotificationGroup8,
|
|
vmwNsxTDataCenterNotificationGroup9,
|
|
vmwNsxTDataCenterNotificationGroup10,
|
|
vmwNsxTDataCenterNotificationGroup11,
|
|
vmwNsxTDataCenterNotificationGroup12,
|
|
vmwNsxTDataCenterNotificationGroup13,
|
|
vmwNsxTDataCenterNotificationGroup14
|
|
}
|
|
::= { vmwNsxTDataCenterCompliances 14 }
|
|
|
|
vmwNsxTDataCenterNotificationInfoGroup14 OBJECT-GROUP
|
|
OBJECTS {
|
|
vmwNsxTDataCenterConstraintLimit,
|
|
vmwNsxTDataCenterConstraintType,
|
|
vmwNsxTDataCenterConstraintTypePath,
|
|
vmwNsxTDataCenterCurrentCount,
|
|
vmwNsxTDataCenterDvsName,
|
|
vmwNsxTDataCenterGroupId,
|
|
vmwNsxTDataCenterGroupMaxNumberLimit,
|
|
vmwNsxTDataCenterGroupSize,
|
|
vmwNsxTDataCenterIPCount,
|
|
vmwNsxTDataCenterIPv4Address,
|
|
vmwNsxTDataCenterIPv6Address,
|
|
vmwNsxTDataCenterLrpCount,
|
|
vmwNsxTDataCenterLspCount,
|
|
vmwNsxTDataCenterMacCount,
|
|
vmwNsxTDataCenterMetricsTargetAddress,
|
|
vmwNsxTDataCenterMetricsTargetAlias,
|
|
vmwNsxTDataCenterMetricsTargetPort,
|
|
vmwNsxTDataCenterNSXaaSServiceName,
|
|
vmwNsxTDataCenterProtocolName,
|
|
vmwNsxTDataCenterSidCount,
|
|
vmwNsxTDataCenterTNCount,
|
|
vmwNsxTDataCenterVMCount,
|
|
vmwNsxTDataCenterVifCount,
|
|
vmwNsxTDataCenterVtepFaultReason,
|
|
vmwNsxTDataCenterVtepName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"These objects provide details in NSX-T Data Center event notifications."
|
|
::= { vmwNsxTDataCenterSMIBGroups 27 }
|
|
|
|
vmwNsxTDataCenterNotificationGroup14 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
vmwNsxTCertificatesTransportNodeCertificateExpirApproaching,
|
|
vmwNsxTCertificatesTransportNodeCertificateExpirApproachingClear,
|
|
vmwNsxTCertificatesTransportNodeCertificateExpired,
|
|
vmwNsxTCertificatesTransportNodeCertificateExpiredClear,
|
|
vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpire,
|
|
vmwNsxTCertificatesTransportNodeCertificateIsAboutToExpireClear,
|
|
vmwNsxTDistributedFirewallDFWFloodLimitCritical,
|
|
vmwNsxTDistributedFirewallDFWFloodLimitCriticalClear,
|
|
vmwNsxTDistributedFirewallDFWFloodLimitWarning,
|
|
vmwNsxTDistributedFirewallDFWFloodLimitWarningClear,
|
|
vmwNsxTGroupsGroupSizeLimitExceeded,
|
|
vmwNsxTGroupsGroupSizeLimitExceededClear,
|
|
vmwNsxTInfrastructureServiceMetricsDeliveryFailure,
|
|
vmwNsxTInfrastructureServiceMetricsDeliveryFailureClear,
|
|
vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachable,
|
|
vmwNsxTMalwarePreventionHealthNTICSRepSvcUnreachableClear,
|
|
vmwNsxTManagerHealthMissingDNSEntryForManagerFQDN,
|
|
vmwNsxTManagerHealthMissingDNSEntryForManagerFQDNClear,
|
|
vmwNsxTManagerHealthMissingDNSEntryForVipFQDN,
|
|
vmwNsxTManagerHealthMissingDNSEntryForVipFQDNClear,
|
|
vmwNsxTPolicyConstraintCreationCountLimitReached,
|
|
vmwNsxTPolicyConstraintCreationCountLimitReachedClear,
|
|
vmwNsxTSecurityCompliancePollEAL4NonCompliance,
|
|
vmwNsxTSecurityCompliancePollEAL4NonComplianceClear,
|
|
vmwNsxTSecurityCompliancePollNDcPPNonCompliance,
|
|
vmwNsxTSecurityCompliancePollNDcPPNonComplianceClear,
|
|
vmwNsxTSecurityComplianceTriggerEAL4NonCompliance,
|
|
vmwNsxTSecurityComplianceTriggerEAL4NonComplianceClear,
|
|
vmwNsxTSecurityComplianceTriggerNDcPPNonCompliance,
|
|
vmwNsxTSecurityComplianceTriggerNDcPPNonComplianceClear,
|
|
vmwNsxTTEPHealthFaultyTEP,
|
|
vmwNsxTTEPHealthFaultyTEPClear,
|
|
vmwNsxTTEPHealthFaultyTEPOnDPU,
|
|
vmwNsxTTEPHealthFaultyTEPOnDPUClear,
|
|
vmwNsxTTEPHealthTEPAutorecoverFailure,
|
|
vmwNsxTTEPHealthTEPAutorecoverFailureClear,
|
|
vmwNsxTTEPHealthTEPAutorecoverFailureOnDPU,
|
|
vmwNsxTTEPHealthTEPAutorecoverFailureOnDPUClear,
|
|
vmwNsxTTEPHealthTEPAutorecoverSuccess,
|
|
vmwNsxTTEPHealthTEPAutorecoverSuccessClear,
|
|
vmwNsxTTEPHealthTEPAutorecoverSuccessOnDPU,
|
|
vmwNsxTTEPHealthTEPAutorecoverSuccessOnDPUClear,
|
|
vmwNsxTTEPHealthTEPHaActivated,
|
|
vmwNsxTTEPHealthTEPHaActivatedClear,
|
|
vmwNsxTTEPHealthTEPHaActivatedOnDPU,
|
|
vmwNsxTTEPHealthTEPHaActivatedOnDPUClear,
|
|
vmwNsxTVMCAppTransitConnectFailure,
|
|
vmwNsxTVMCAppTransitConnectFailureClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Group of objects describing event notifications emitted by
|
|
NSX-T Data Center.
|
|
"
|
|
::= { vmwNsxTDataCenterSMIBGroups 28 }
|
|
|
|
END
|