Observium_CE/mibs/trango/TRANGOP5830S-MU-MIB

882 lines
33 KiB
Plaintext

-- Private MIB definition for Trango Systems
-- Access 58xx series wireless broadband Master Unit P5830S
-- Version: 1.0
-- Date: June 10, 2003
--
-- Copyright 2003: Trango Systems, Inc. All Rights Reserved.
-- Trango Systems, Inc. 15070 Avenue Of Science Suite 200 San Diego CA 92128 USA.
--
-- Reproduction of this document is authorized on condition that the
-- foregoing copyright notice is included.
TRANGOP5830S-MU-MIB DEFINITIONS ::= BEGIN
-- MIB module for enterprise trango wireless broadband
-- of management of P5830S master unit
IMPORTS
enterprises, IpAddress, Counter
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212;
-- textual conventions
DisplayString ::=
OCTET STRING
-- This data type is used to model textual information taken
-- from the NVT ASCII character set. By convention, objects
-- with this syntax are declared as having
--
-- SIZE (0..255)
-- trango wireless broadband MIB registration id assigned to 5454.
-- customer needs to change this value based on their OEM value.
trango OBJECT IDENTIFIER ::= { enterprises 5454 }
tbw OBJECT IDENTIFIER ::= { trango 1 }
p5830smu OBJECT IDENTIFIER ::= { tbw 22 }
-- modules branched from p5830smu
musys OBJECT IDENTIFIER ::= { p5830smu 1 }
murf OBJECT IDENTIFIER ::= { p5830smu 2 }
ru OBJECT IDENTIFIER ::= { p5830smu 3 }
trapconfig OBJECT IDENTIFIER ::= { p5830smu 4 }
mibinfo OBJECT IDENTIFIER ::= { p5830smu 5 }
muversion OBJECT IDENTIFIER ::= { musys 1 }
muswitches OBJECT IDENTIFIER ::= { musys 8}
mutraffic OBJECT IDENTIFIER ::= { musys 9}
muipconfig OBJECT IDENTIFIER ::= { musys 13}
murftable OBJECT IDENTIFIER ::= { murf 4 }
muism OBJECT IDENTIFIER ::= { murf 5 }
muunii OBJECT IDENTIFIER ::= { murf 6 }
-- MIB objects defined below
-- master unit system objects
muversionHW OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Hardware version."
::= { muversion 1 }
muversionFW OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Main firmware version.
Format: <code version>H<hardware version>D<date>."
::= { muversion 2 }
muversionFPGA OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"FPGA firmware version."
::= { muversion 3 }
muversionFWChecksum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Master unit firmware checksum."
::= { muversion 4 }
muversionFPGAChecksum OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Master unit FPGA checksum."
::= { muversion 5 }
musysDeviceId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Master unit device Id. Each master unit in a cluster shall have unique ID."
::= { musys 2 }
musysDefOpMode OBJECT-TYPE
SYNTAX INTEGER {
on(16),
off(0)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The operation mode (on or off) the master unit is on after reboot/power cycle."
::= { musys 3 }
musysCurOpMode OBJECT-TYPE
SYNTAX INTEGER {
on(16),
off(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Master unit's current operation mode."
::= { musys 4 }
musysActivateOpmode OBJECT-TYPE
SYNTAX INTEGER {
deactivated(0),
activated(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Engage master unit to on operation mode."
DEFVAL { deactivated }
::= { musys 5 }
musysReadCommStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNMP agent read community string. It is used for authentication purpose."
::= { musys 6 }
musysWriteCommStr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"SNMP agent write community string. It is used for authentication purpose."
::= { musys 7 }
muswitchesBlockBroadcastMulticast OBJECT-TYPE
SYNTAX INTEGER {
passed(0),
blocked(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This switch enables or disables the blocking of Ethernet
control packet except ICMP and ARP to reduce the amount
of uneccessary overhead introduced to the wireless link."
::= { muswitches 1 }
muswitchesHTTPD OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When it is turned on, then the master unit is accessible
for configuring via web browser (e.g. IE or Nescape)."
::= { muswitches 5 }
muswitchesAutoPowerLevelRemoteUnit OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When it is turned on, then the master unit will
command the remote unit to do power leveling."
::= { muswitches 7 }
mutrafficEthInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of payload octets received on Ethernet port."
::= { mutraffic 1 }
mutrafficEthOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of payload octets transmitted on Ethernet port."
::= { mutraffic 2 }
mutrafficRfInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets of remote's payload received from RF port."
::= { mutraffic 3 }
mutrafficRfOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets of remote's payload transmitted to RF port."
::= { mutraffic 4 }
musysTemperature OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current master unit's temperature value (in Celsius)."
::= { musys 10 }
musysUpdateFlashAndActivate OBJECT-TYPE
SYNTAX INTEGER {
no(0),
yes(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Save system setting values to Flash and activate the settings."
DEFVAL {no}
::= { musys 11 }
musysReboot OBJECT-TYPE
SYNTAX INTEGER {
deactivated(0),
activated(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reboot the master unit."
DEFVAL { deactivated }
::= { musys 12 }
muipconfigIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"New IP address. It will be saved to
non-volatile memory and activated in 5 secs."
::= { muipconfig 1 }
muipconfigSubnet OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"New Subnet mask. It will be saved to
non-volatile memory and activated in 5 secs."
::= { muipconfig 2 }
muipconfigDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"New Default gateway. It will be saved to
non-volatile memory and activated in 5 secs."
::= { muipconfig 3 }
-- master unit rf objects
murfRSSI OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote unit RSSI (in dBm)."
::= { murf 1 }
murfActiveChannel OBJECT-TYPE
SYNTAX INTEGER (1..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"It specifies the current channel number the master unit operates on."
::= { murf 2 }
murfActivePolarization OBJECT-TYPE
SYNTAX DisplayString (SIZE (1))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"It specifies the current polarization the master unit operates on."
::= { murf 3 }
murftableChannel1 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 1 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 1 }
murftableChannel2 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 2 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 2 }
murftableChannel3 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 3 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 3 }
murftableChannel4 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 4 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 4 }
murftableChannel5 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 5 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 5 }
murftableChannel6 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 6 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 6 }
murftableChannel7 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 7 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 7 }
murftableChannel8 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 8 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 8 }
murftableChannel9 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 9 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 9 }
murftableChannel10 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 10 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 10 }
murftableChannel11 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 11 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 11 }
murftableChannel12 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 12 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 12 }
murftableChannel13 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 13 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 13 }
murftableChannel14 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 14 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 14 }
murftableChannel15 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 15 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 15 }
murftableChannel16 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 16 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 16 }
murftableChannel17 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 17 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 17 }
murftableChannel18 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 18 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 18 }
murftableChannel19 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 19 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 19 }
murftableChannel20 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 20 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 20 }
murftableChannel21 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 21 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 21 }
murftableChannel22 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 22 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 22 }
murftableChannel23 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 23 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 23 }
murftableChannel24 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 24 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 24 }
murftableChannel25 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 25 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 25 }
murftableChannel26 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 26 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 26 }
murftableChannel27 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 27 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 27 }
murftableChannel28 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 28 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 28 }
murftableChannel29 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 29 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 29 }
murftableChannel30 OBJECT-TYPE
SYNTAX INTEGER (5260..5340 | 5736..5836)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"RF channel 30 frequency (in MHz). It allows you to create your
own channel instead of the manufacturing defaults in the master unit.
Keep in mind that channel width is 20MHz, and the frequency
specified here is the center frequency.
Frequency (5260MHz - 5340MHz) is only applicable to M5830S/P5830S radio."
::= { murftable 30 }
muismTxPowerMax OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum ISM Tx power value can be set (in dBm)."
::= { muism 1 }
muismTxPowerMin OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum ISM Tx power value can be set (in dBm)."
::= { muism 2 }
muismTxPower OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ISM RF tx power (in dBm). It specifies the power output
of the radio, excluding the antenna gain. Check parameters
muismTxPowerMax and masterismTxPowerMin for power setting range."
::= { muism 3 }
muismRxThreshold OBJECT-TYPE
SYNTAX INTEGER (-90 | -85 | -80 | -75 | -70 | -65)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ISM RF rx threshold (in dBm). It specifies the receiver
sensitivity of the master. By default, the radio's sensitivity is -82dBm.
The higher the threshold is, the less sensitive the radio will be.
In M5800S, the value -90 represents the rfrxthreshold is disabled."
::= { muism 4 }
muismTargetRSSI OBJECT-TYPE
SYNTAX INTEGER (-85..-45)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ISM RF RSSI (in dBm). It specifies the target RSSI from the remote unit
to the master unit. Based on this parameter, the master unit can power level
the remote unit so that it receives same level of signal strength from
the remote unit, regardless far or near. Note that when you set the Target RSSI
from the remote unit, you need to consider master unit's RF Rx Threshold value.
The Target RSSI from the remote unit must be 5dB higher than the RF Rx
Threshold. When the RF Rx Threshold is disabled, the setting of the Target
RSSI from remote unit shall be no less than -75dBm."
::= { muism 5 }
muuniiTxPowerMax OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is only applicable to M5830S/P5830S radio.
The maximum UNII Tx power value can be set (in dBm)."
::= { muunii 1 }
muuniiTxPowerMin OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object is only applicable to M5830S/P5830S radio.
The minimum UNII Tx power value can be set (in dBm)."
::= { muunii 2 }
muuniiTxPower OBJECT-TYPE
SYNTAX INTEGER (-128..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is only applicable to M5830S/P5830S radio.
UNII RF tx power (in dBm). It specifies the power output
of the radio, excluding the antenna gain. Check parameters
apuniiTxPowerMax and apuniiTxPowerMin for power setting range."
::= { muunii 3 }
muuniiRxThreshold OBJECT-TYPE
SYNTAX INTEGER (-90 | -85 | -80 | -75 | -70 | -65)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is only applicable to M5830S/P5830S radio.
UNII RF rx threshold (in dBm). It specifies the receiver sensitivity of the master."
::= { muunii 4 }
muuniiTargetRSSI OBJECT-TYPE
SYNTAX INTEGER (-85..-45)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object is only applicable to M5830S/P5830S radio.
UNII RF target RSSI (in dBm). It specifies the target RSSI from
remote unit to the master unit. Based on this parameter, the master can power
level the remote unit so that it receives same level of signal strength from
the remote unit, regardless far or near. Note that when you set the Target RSSI
from the remote unit, you need to consider remote unit's RF Rx Threshold value.
The Target RSSI from the remote unit must be 5dB higher than the RF Rx Threshold."
::= { muunii 5 }
-- remote unit objects
ruDeviceId OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Remote unit device ID."
::= { ru 1 }
ruUpstreamMIR OBJECT-TYPE
SYNTAX INTEGER (100..10000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"It is the Maximum Information Rate (in Kbps)
the master unit allocates to remote unit."
DEFVAL { 128 }
::= { ru 2 }
remoteDownstreamMIR OBJECT-TYPE
SYNTAX INTEGER (100..10000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"It is the Maximum Information Rate (in Kbps)
the master unit allocates to the remote unit."
DEFVAL { 9999 }
::= { ru 3 }
ruPowerLvl OBJECT-TYPE
SYNTAX INTEGER {
deactivated(0),
activated(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"It is a feature that is typically found in more
elaborate mobile systems such as cellular CDMA
networks. Using this feature, the remote unit have its
RF power output adjusted until its signal strength
received in the master unit is roughly the same."
DEFVAL {deactivated}
::= { ru 4 }
ruReboot OBJECT-TYPE
SYNTAX INTEGER {
deactivated(0),
activated(1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Master unit issues reboot command to remote unit."
DEFVAL { deactivated }
::= { ru 5 }
ruAssociation OBJECT-TYPE
SYNTAX INTEGER {
associated(1),
notAssociated(0)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Remote unit association status."
::= { ru 6 }
ruDistance OBJECT-TYPE
SYNTAX INTEGER (0..40)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Distance of remote unit (in mile)."
::= { ru 7 }
-- trapconfig objects
trapconfigDest1IPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap destination 1 IP address."
::= { trapconfig 2 }
trapconfigDest2IPAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Trap destination 2 IP address."
::= { trapconfig 3 }
-- MIB version object
mibinfoVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Trango master unit MIB Version."
::= { mibinfo 1 }
-- Trap objects
-- End of file <trango_P5830S_MU_1p0.mib>
END