215 lines
5.8 KiB
Plaintext
215 lines
5.8 KiB
Plaintext
TRANGO-APEX-TRAP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
OBJECT-IDENTITY,
|
|
Unsigned32,
|
|
NOTIFICATION-TYPE,
|
|
apex
|
|
FROM TRANGO-APEX-MIB
|
|
|
|
MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF;
|
|
|
|
DisplayString ::= OCTET STRING
|
|
|
|
-- *******************************************************************
|
|
-- ** Trap Information ** trango.twb.apex.trangotrap
|
|
-- *******************************************************************
|
|
|
|
trangotrap OBJECT IDENTIFIER ::= { apex 6 }
|
|
|
|
trapReboot NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the system reboots"
|
|
::= { trangotrap 1 }
|
|
|
|
trapStartUp NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the system starts up"
|
|
::= { trangotrap 2 }
|
|
|
|
traplock OBJECT IDENTIFIER ::= { trangotrap 3 }
|
|
|
|
trapModemLock NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the system lose modem lock"
|
|
::= { traplock 1 }
|
|
|
|
trapTimingLock NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "Timing Lock in modem changed"
|
|
::= { traplock 2 }
|
|
|
|
trapInnerCodeLock NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the system lose Inner Code lock"
|
|
::= { traplock 3 }
|
|
|
|
trapEqualizerLock NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the system lose Equalizer lock"
|
|
::= { traplock 4 }
|
|
|
|
trapFrameSyncLock NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the system lose Frame Sync lock"
|
|
::= { traplock 5 }
|
|
|
|
trapthreshold OBJECT IDENTIFIER ::= { trangotrap 4 }
|
|
|
|
trapmse OBJECT IDENTIFIER ::= { trapthreshold 1 }
|
|
|
|
trapMSEMinThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the MSE fall out from the threshold"
|
|
::= { trapmse 1 }
|
|
|
|
trapMSEMaxThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the MSE fall out from the threshold"
|
|
::= { trapmse 2 }
|
|
|
|
trapber OBJECT IDENTIFIER ::= { trapthreshold 2 }
|
|
|
|
trapBERMinThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the BER fall out from the threshold"
|
|
::= { trapber 1 }
|
|
|
|
trapBERMaxThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the BER fall out from the threshold"
|
|
::= { trapber 2 }
|
|
|
|
trapfer OBJECT IDENTIFIER ::= { trapthreshold 3 }
|
|
|
|
trapFERMinThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the FER fall out from the threshold"
|
|
::= { trapfer 1 }
|
|
|
|
trapFERMaxThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the FER fall out from the threshold"
|
|
::= { trapfer 2 }
|
|
|
|
traprssi OBJECT IDENTIFIER ::= { trapthreshold 4 }
|
|
|
|
trapRSSIMinThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the RSSI fall out from the threshold"
|
|
::= { traprssi 1 }
|
|
|
|
trapRSSIMaxThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the RSSI fall out from the threshold"
|
|
::= { traprssi 2 }
|
|
|
|
trapidutemp OBJECT IDENTIFIER ::= { trapthreshold 5 }
|
|
|
|
trapIDUTempMinThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the ethernet status exceed threshold"
|
|
::= { trapidutemp 1 }
|
|
|
|
trapIDUTempMaxThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the ethernet status exceed threshold"
|
|
::= { trapidutemp 2 }
|
|
|
|
trapodutemp OBJECT IDENTIFIER ::= { trapthreshold 6 }
|
|
|
|
trapODUTempMinThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the T1 status exceed threshold"
|
|
::= { trapodutemp 1 }
|
|
|
|
trapODUTempMaxThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the T1 status exceed threshold"
|
|
::= { trapodutemp 2 }
|
|
|
|
trapinport OBJECT IDENTIFIER ::= { trapthreshold 7 }
|
|
|
|
trapInPortUtilMinThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the IN port utilization fall below min threshold"
|
|
::= { trapinport 1 }
|
|
|
|
trapInPortUtilMaxThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the IN port utilization exceed max threshold"
|
|
::= { trapinport 2 }
|
|
|
|
trapoutport OBJECT IDENTIFIER ::= { trapthreshold 8 }
|
|
|
|
trapOutPortUtilMinThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the OUT port utilization fall below min threshold"
|
|
::= { trapoutport 1 }
|
|
|
|
trapOutPortUtilMaxThreshold NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the OUT port utilization exceed max threshold"
|
|
::= { trapoutport 2 }
|
|
|
|
trapstandby OBJECT IDENTIFIER ::= { trangotrap 5 }
|
|
|
|
trapStandbyLinkDown NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when Standby link is down"
|
|
::= { trapstandby 1 }
|
|
|
|
trapStandbyLinkUp NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when Standby link is up"
|
|
::= { trapstandby 2 }
|
|
|
|
trapSwitchover NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when backup unit takes over the link"
|
|
::= { trapstandby 3 }
|
|
|
|
trapeth OBJECT IDENTIFIER ::= { trangotrap 6 }
|
|
|
|
trapethstatus OBJECT IDENTIFIER ::= { trapeth 1 }
|
|
|
|
trapEth1StatusUpdate NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when ethernet port 1 status changed"
|
|
::= { trapethstatus 1 }
|
|
|
|
trapEth2StatusUpdate NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when ethernet port 2 status changed"
|
|
::= { trapethstatus 2 }
|
|
|
|
trapEth3StatusUpdate NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when ethernet port 3 status changed"
|
|
::= { trapethstatus 3 }
|
|
|
|
trapEth4StatusUpdate NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when ethernet port 4 status changed"
|
|
::= { trapethstatus 4 }
|
|
|
|
trapDownShift NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the system downshift the modulation"
|
|
::= { trangotrap 8 }
|
|
|
|
trapRapidPortShutdown NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the rapid port shutdown occurs"
|
|
::= { trangotrap 9 }
|
|
|
|
trapRPSPortUp NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION "send traps when the re-enable ports after RPS port down"
|
|
::= { trangotrap 10 }
|
|
|
|
END
|