-- Copyright(c) 2008-2012 Shenzhen TP-LINK Technologies Co.,Ltd.
--
-- FileName : tplink-sflow.mib
-- Description :
-- Reference :
-- Version : 1.0
-- History :
-- Yu ChangYe, 2015.9.19, Created.
--
-- ============================================================================
TPLINK-SFLOW-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE,MODULE-IDENTITY,IpAddress
FROM SNMPv2-SMI
tplinkMgmt
FROM TPLINK-MIB
DisplayString
FROM SNMPv2-TC
ifIndex
FROM RFC1213-MIB;
tplinkSflowMIB MODULE-IDENTITY
LAST-UPDATED "201509231007Z"
ORGANIZATION "TPLINK"
CONTACT-INFO "www.tplink.com"
DESCRIPTION "Private MIB for the sFlow configuration."
REVISION "201509231007Z"
DESCRIPTION
"Initial version of this MIB module."
::= { tplinkMgmt 95 }
tplinkSflowMIBObjects OBJECT IDENTIFIER ::= { tplinkSflowMIB 1 }
-- tplinkSflowNotifications OBJECT IDENTIFIER ::= { tplinkSflowMIB 2 }
tpSflowGlobalConfig OBJECT IDENTIFIER ::= {tplinkSflowMIBObjects 1}
tpSflowCollector OBJECT IDENTIFIER ::= {tplinkSflowMIBObjects 2}
tpSflowSampler OBJECT IDENTIFIER ::= {tplinkSflowMIBObjects 3}
-- the sflow GlobalConfig
tpSflowGlobalConfigStatus OBJECT-TYPE
SYNTAX INTEGER {
disable(0),
enable(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Allows you to Enable/Disable the sFlow function.
0. disable
1. enable"
::= { tpSflowGlobalConfig 1 }
tpSflowGlobalConfigAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The IP address of the agent."
::= { tpSflowGlobalConfig 2 }
tpSflowGlobalConfigVersion OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The sFlow version number."
::= {tpSflowGlobalConfig 3}
-- the sflow collector
tpSflowCollectorTable OBJECT-TYPE
SYNTAX SEQUENCE OF TpSflowCollectorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of sflow collector entries.
Here you can configure the sflow collector."
::= { tpSflowCollector 1 }
tpSflowCollectorEntry OBJECT-TYPE
SYNTAX TpSflowCollectorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry contains the information of sflow collector."
INDEX { tpSflowCollectorCollectorId }
::= { tpSflowCollectorTable 1 }
TpSflowCollectorEntry ::=
SEQUENCE {
tpSflowCollectorCollectorId
INTEGER,
tpSflowCollectorDescription
DisplayString,
tpSflowCollectorCollectorIp
IpAddress,
tpSflowCollectorCollectorPort
INTEGER,
tpSflowCollectorMaxDatagram
INTEGER,
tpSflowCollectorTimeout
INTEGER,
tpSflowCollectorLifetime
INTEGER
}
tpSflowCollectorCollectorId OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The collector ID."
::= { tpSflowCollectorEntry 1 }
tpSflowCollectorDescription OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This description of the collector."
::= {tpSflowCollectorEntry 2}
tpSflowCollectorCollectorIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the collector"
::= { tpSflowCollectorEntry 3 }
tpSflowCollectorCollectorPort OBJECT-TYPE
SYNTAX INTEGER(1..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The UDP port of the collector."
::= { tpSflowCollectorEntry 4 }
tpSflowCollectorMaxDatagram OBJECT-TYPE
SYNTAX INTEGER(300..1400)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The max datagram of the collector."
::= { tpSflowCollectorEntry 5 }
tpSflowCollectorTimeout OBJECT-TYPE
SYNTAX INTEGER(0..2000000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout value of the collector."
::= { tpSflowCollectorEntry 6 }
tpSflowCollectorLifetime OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The lifetime of the collector."
::= { tpSflowCollectorEntry 7 }
-- the sflow sampler
tpSflowSamplerTable OBJECT-TYPE
SYNTAX SEQUENCE OF TpSflowSamplerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of sflow sampler entries.
Here you can configure the sflow sampler."
::= { tpSflowSampler 1 }
tpSflowSamplerEntry OBJECT-TYPE
SYNTAX TpSflowSamplerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry contains the information of the sflow sampler."
INDEX { ifIndex }
::= { tpSflowSamplerTable 1 }
TpSflowSamplerEntry ::=
SEQUENCE {
tpSflowSamplerPort
DisplayString,
tpSflowSamplerCollectorId
INTEGER,
tpSflowSamplerIngRate
INTEGER,
tpSflowSamplerEgRate
INTEGER,
tpSflowSamplerMaxHeader
INTEGER,
tpSflowSamplerPortLag
OCTET STRING (SIZE (1..255))
}
tpSflowSamplerPort OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The port number of the switch."
::= { tpSflowSamplerEntry 1 }
tpSflowSamplerCollectorId OBJECT-TYPE
SYNTAX INTEGER(0..4)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The collector ID."
::= { tpSflowSamplerEntry 2 }
tpSflowSamplerIngRate OBJECT-TYPE
SYNTAX INTEGER(0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ratio of ingress packets to the samples generated(Range:0, 1024-65535)."
::= { tpSflowSamplerEntry 3 }
tpSflowSamplerEgRate OBJECT-TYPE
SYNTAX INTEGER(0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ratio of egress packets to the samples generated(Range:0, 1024-65535)."
::= { tpSflowSamplerEntry 4 }
tpSflowSamplerMaxHeader OBJECT-TYPE
SYNTAX INTEGER(18..256)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum number of bytes that should be sampled."
::= { tpSflowSamplerEntry 5 }
tpSflowSamplerPortLag OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The LAG number which the port belongs to."
::= { tpSflowSamplerEntry 6 }
END