Observium_CE/mibs/supermicro/SUPERMICRO-PING-MIB

183 lines
5.4 KiB
Plaintext

-- Copyright (C) 2008-2014 Super Micro Computer Inc. All Rights Reserved
-- /*****************************************************************
-- * *
-- * $RCSfile: fsping.mib,v $
-- * *
-- * $Date: 2012/09/07 09:52:05 $ *
-- * *
-- * $Revision: 1.6 $ *
-- * *
-- ****************************************************************/
SUPERMICRO-PING-MIB DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE, MODULE-IDENTITY, IpAddress,
Counter32, Integer32,
enterprises FROM SNMPv2-SMI
RowStatus FROM SNMPv2-TC;
fsPingMIB MODULE-IDENTITY
LAST-UPDATED "201209050000Z"
ORGANIZATION "Super Micro Computer Inc."
CONTACT-INFO "support@Supermicro.com"
DESCRIPTION " This mib is for Ping module"
REVISION "201209050000Z"
DESCRIPTION " This mib is for Ping module"
::= { enterprises supermicro-computer-inc(10876) super-switch(101) basic(1) 106}
fsPingMIBObjects OBJECT IDENTIFIER ::= { fsPingMIB 1 }
--This is the MIB for IP Ping functionality
fsPingTable OBJECT-TYPE
SYNTAX SEQUENCE OF FsPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entity's IP Ping Table"
::= { fsPingMIBObjects 1 }
fsPingEntry OBJECT-TYPE
SYNTAX FsPingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Contains the information about a particular IP ping
Instance.Objects in this table can not be updated when
the PingStatus is in progress"
INDEX { fsPingIndex }
::= { fsPingTable 1 }
FsPingEntry ::=
SEQUENCE {
fsPingIndex Integer32,
fsPingDest IpAddress,
fsPingTimeout Integer32,
fsPingTries Integer32,
fsPingDataSize Integer32,
fsPingStatus INTEGER,
fsPingSendCount Integer32,
fsPingAverageTime Integer32,
fsPingMaxTime Integer32,
fsPingMinTime Integer32,
fsPingSuccesses Counter32,
fsPingEntryStatus RowStatus
}
fsPingIndex OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Unique value that identifies the Ping Entry"
::= { fsPingEntry 1 }
fsPingDest OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The IP address of the node to be pinged."
::= { fsPingEntry 2 }
fsPingTimeout OBJECT-TYPE
SYNTAX Integer32 (1..100)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The time in seconds after which the entity waiting
for the ping response times out."
DEFVAL { 1 }
::= { fsPingEntry 3 }
fsPingTries OBJECT-TYPE
SYNTAX Integer32 (1..1000)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The number of times the given node address is to be
pinged."
DEFVAL { 3 }
::= { fsPingEntry 4 }
fsPingDataSize OBJECT-TYPE
SYNTAX Integer32 (0..2080)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The size of the data portion of the PING PDU in bytes"
DEFVAL { 64 }
::= { fsPingEntry 5 }
fsPingStatus OBJECT-TYPE
SYNTAX INTEGER {
notinitiated (1),
progress (2),
completed (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current status of the Ping Entry"
::= { fsPingEntry 6 }
fsPingSendCount OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of packets sent to destination."
::= { fsPingEntry 7 }
fsPingAverageTime OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average value of the round trip time in milli seconds
to this destination."
::= { fsPingEntry 8 }
fsPingMaxTime OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum value of the round trip time in milli seconds
to this destination."
::= { fsPingEntry 9 }
fsPingMinTime OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum value of the round trip time in milli seconds
to this destination."
::= { fsPingEntry 10 }
fsPingSuccesses OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of ping responses received."
::= { fsPingEntry 11 }
fsPingEntryStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of this table entry. Once the entry status is
set to active, the associate entry cannot be modified until
the sequence completes (PingStatus is completed).Management
station created the Ping Entries should take care of
deletion. Entry Can be made active only if PingDestination is
configured"
::= { fsPingEntry 12 }
END