RC-RMON-MIB-AC DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, Integer32 FROM SNMPv2-SMI
|
|
AGENT-CAPABILITIES FROM SNMPv2-CONF
|
|
OwnerString FROM RMON-MIB
|
|
ruggedcomAgentCapability FROM RUGGEDCOM-MIB;
|
|
|
|
ruggedcomRmonACModule MODULE-IDENTITY
|
|
LAST-UPDATED "201102221700Z" -- Feb 22, 17:00 EST 2011;
|
|
ORGANIZATION "RuggedCom - Industrial Strength Networks"
|
|
CONTACT-INFO
|
|
"Postal: RuggedCom Inc.
|
|
300 Applewood Crescent
|
|
Concord, Ontario,
|
|
L4K 5C7 Canada
|
|
Tel: 1-905-856-5288
|
|
E-Mail: support@ruggedcom.com"
|
|
DESCRIPTION
|
|
"The capabilities description for RMON-MIB."
|
|
|
|
REVISION "201102221700Z" -- Feb 22, 17:00 EST 2011;
|
|
DESCRIPTION
|
|
"Initial version of this MIB module."
|
|
|
|
::= { ruggedcomAgentCapability 9 }
|
|
-- ---------------------------------------------------------------------- --
|
|
-- RMON MIB Agent Capabilities
|
|
-- ---------------------------------------------------------------------- --
|
|
ruggedcomRmonAC AGENT-CAPABILITIES
|
|
PRODUCT-RELEASE "ROS-CF52"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RMON-MIB Agent Capabilities."
|
|
|
|
SUPPORTS RMON-MIB
|
|
-- rfc2819.txt
|
|
|
|
INCLUDES { rmonEtherStatsGroup, rmonHistoryControlGroup,
|
|
rmonEthernetHistoryGroup, rmonAlarmGroup,
|
|
rmonEventGroup }
|
|
|
|
VARIATION etherStatsIndex
|
|
DESCRIPTION
|
|
"Two entries per port are created in etherStatsTable."
|
|
|
|
VARIATION etherStatsOwner
|
|
DESCRIPTION
|
|
"The value of this entry is always set to 'Monitor' and
|
|
may not be modified."
|
|
|
|
VARIATION etherStatsStatus
|
|
DESCRIPTION
|
|
"One entry per port is created in etherStatsTable upon
|
|
initialization up. These entries may not be modified
|
|
or deleted.
|
|
No new entries can be created.
|
|
Therefore, historyControlStatus always set to 'valid(1)'."
|
|
|
|
VARIATION historyControlIndex
|
|
DESCRIPTION
|
|
"An average of four entries per ethernet port can be created
|
|
in historyControlTable."
|
|
|
|
VARIATION historyControlBucketsRequested
|
|
SYNTAX Integer32(1..4000)
|
|
DESCRIPTION
|
|
"The value of historyControBucketRequested is restricted
|
|
to 4000."
|
|
|
|
VARIATION historyControlOwner
|
|
SYNTAX OwnerString
|
|
DEFVAL { "Monitor" }
|
|
DESCRIPTION
|
|
"A default value of a historyControlOwner is a
|
|
'Monitor' string."
|
|
|
|
VARIATION alarmIndex
|
|
DESCRIPTION
|
|
"An average of four entries per port can be created
|
|
in alarmTable."
|
|
|
|
VARIATION alarmInterval
|
|
SYNTAX Integer32
|
|
DEFVAL { 60 }
|
|
DESCRIPTION
|
|
"A default value of an alarmInterval is 60 seconds."
|
|
|
|
VARIATION alarmSampleType
|
|
SYNTAX INTEGER {
|
|
absosluteValue(1),
|
|
deltaValue(2)
|
|
}
|
|
DEFVAL { deltaValue }
|
|
DESCRIPTION
|
|
"A default value of an alarmSampleType is 'deltaValue(2)'."
|
|
|
|
VARIATION alarmStartupAlarm
|
|
SYNTAX INTEGER {
|
|
risingAlarm(1),
|
|
fallingAlarm(2),
|
|
risingOrFallingAlarm(3)
|
|
}
|
|
DEFVAL { risingOrFallingAlarm }
|
|
DESCRIPTION
|
|
"A default value of alarmStartupAlarm is
|
|
'risingOrFallingAlarm(3)'."
|
|
|
|
VARIATION alarmOwner
|
|
DEFVAL { "Monitor" }
|
|
DESCRIPTION
|
|
"A default value of an alarmOwner is a 'Monitor'
|
|
string."
|
|
|
|
VARIATION eventIndex
|
|
DESCRIPTION
|
|
"An average of one entry per alarmEntry may be created
|
|
in eventTable."
|
|
|
|
VARIATION eventType
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
log(2),
|
|
snmptrap(3),
|
|
logandtrap(4)
|
|
}
|
|
DEFVAL { none }
|
|
DESCRIPTION
|
|
"A default value of an eventType is 'logandtrap(4)'."
|
|
|
|
VARIATION eventCommunity
|
|
DESCRIPTION
|
|
"The string of up to 30 characters is supported for this
|
|
object."
|
|
|
|
VARIATION eventOwner
|
|
SYNTAX OwnerString
|
|
DEFVAL { "Monitor" }
|
|
DESCRIPTION
|
|
"A default value of an eventOwner is a 'Monitor' string."
|
|
|
|
VARIATION logIndex
|
|
DESCRIPTION
|
|
"For each eventEntry a hundred of entries in logTable may
|
|
be created. The value of thi object will increase for each
|
|
new log generated for coresponding event. When value of
|
|
this object becomes greater than 100, oldest entries will
|
|
be deleted."
|
|
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
::= { ruggedcomRmonACModule 1 }
|
|
|
|
ruggedcomRmonAC01 AGENT-CAPABILITIES
|
|
PRODUCT-RELEASE "Ruggedcom ROX 2.4.1"
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RMON-MIB Agent Capabilities."
|
|
|
|
SUPPORTS RMON-MIB
|
|
-- rfc2819.txt
|
|
|
|
INCLUDES {rmonEtherStatsGroup }
|
|
|
|
-- ROS supports the following groups that we don't support yet
|
|
-- rmonHistoryControlGroup,rmonEthernetHistoryGroup
|
|
-- rmonAlarmGroup
|
|
-- rmonEventGroup
|
|
|
|
VARIATION etherStatsOwner
|
|
DESCRIPTION
|
|
"The value of this entry is always set to 'Monitor' and
|
|
may not be modified."
|
|
|
|
VARIATION etherStatsStatus
|
|
DESCRIPTION
|
|
"One entry per port is created in etherStatsTable upon
|
|
initialization up. These entries may not be modified
|
|
or deleted.
|
|
No new entries can be created.
|
|
Therefore, historyControlStatus always set to 'valid(1)'."
|
|
|
|
VARIATION historyControlIndex
|
|
DESCRIPTION
|
|
"An average of four entries per ethernet port can be created
|
|
in historyControlTable."
|
|
|
|
VARIATION historyControlBucketsRequested
|
|
SYNTAX Integer32(1..4000)
|
|
DESCRIPTION
|
|
"The value of historyControBucketRequested is restricted
|
|
to 4000."
|
|
|
|
VARIATION historyControlOwner
|
|
SYNTAX OwnerString
|
|
DEFVAL { "Monitor" }
|
|
DESCRIPTION
|
|
"A default value of a historyControlOwner is a
|
|
'Monitor' string."
|
|
|
|
VARIATION alarmIndex
|
|
DESCRIPTION
|
|
"An average of four entries per port can be created
|
|
in alarmTable."
|
|
|
|
VARIATION alarmInterval
|
|
SYNTAX Integer32
|
|
DEFVAL { 60 }
|
|
DESCRIPTION
|
|
"A default value of an alarmInterval is 60 seconds."
|
|
|
|
VARIATION alarmSampleType
|
|
SYNTAX INTEGER {
|
|
absosluteValue(1),
|
|
deltaValue(2)
|
|
}
|
|
DEFVAL { deltaValue }
|
|
DESCRIPTION
|
|
"A default value of an alarmSampleType is 'deltaValue(2)'."
|
|
|
|
VARIATION alarmStartupAlarm
|
|
SYNTAX INTEGER {
|
|
risingAlarm(1),
|
|
fallingAlarm(2),
|
|
risingOrFallingAlarm(3)
|
|
}
|
|
DEFVAL { risingOrFallingAlarm }
|
|
DESCRIPTION
|
|
"A default value of alarmStartupAlarm is
|
|
'risingOrFallingAlarm(3)'."
|
|
|
|
-- VARIATION alarmOwner --
|
|
-- DEFVAL { "Monitor" } --
|
|
-- DESCRIPTION --
|
|
-- "A default value of an alarmOwner is a 'Monitor' --
|
|
-- string." --
|
|
|
|
VARIATION eventIndex
|
|
DESCRIPTION
|
|
"An average of one entry per alarmEntry may be created
|
|
in eventTable."
|
|
|
|
VARIATION eventType
|
|
SYNTAX INTEGER {
|
|
none(1),
|
|
log(2),
|
|
snmptrap(3),
|
|
logandtrap(4)
|
|
}
|
|
DEFVAL { none }
|
|
DESCRIPTION
|
|
"A default value of an eventType is 'logandtrap(4)'."
|
|
|
|
VARIATION eventCommunity
|
|
DESCRIPTION
|
|
"The string of up to 30 characters is supported for this
|
|
object."
|
|
|
|
VARIATION eventOwner
|
|
SYNTAX OwnerString
|
|
DEFVAL { "Monitor" }
|
|
DESCRIPTION
|
|
"A default value of an eventOwner is a 'Monitor' string."
|
|
|
|
VARIATION logIndex
|
|
DESCRIPTION
|
|
"For each eventEntry a hundred of entries in logTable may
|
|
be created. The value of this object will increase for each
|
|
new log generated for coresponding event. When value of
|
|
this object becomes greater than 100, oldest entries will
|
|
be deleted."
|
|
|
|
-- ---------------------------------------------------------------------- --
|
|
::= { ruggedcomRmonACModule 2 }
|
|
|
|
END
|