-- Module Name: HMS132R3.MIB (SCTE 94-2)
-- SCTE Status: Draft Revision 3
SCTE-HMS-HE-RF-SWITCH-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
OBJECT-TYPE, MODULE-IDENTITY, Unsigned32, Integer32
FROM SNMPv2-SMI
DisplayString
FROM SNMPv2-TC
entPhysicalIndex
FROM ENTITY-MIB
HeFaultStatus, HeTenthdB,
HeTenthdBm, HeTenthdBmV, HeOnOffControl
FROM SCTE-HMS-HEADENDIDENT-MIB
heRFSwitchGroup
FROM SCTE-HMS-HE-RF-MIB;
heRFSwitchMIB MODULE-IDENTITY
LAST-UPDATED "200309110000Z" -- Sep 11, 2003
ORGANIZATION "SCTE HMS Working Group"
CONTACT-INFO
"SCTE HMS Subcommittee, Chairman
mailto: standards@SCTE.org"
DESCRIPTION
" Change Log:
1. Added Unsigned32 and Integer32 to IMPORTS
2. Removed TEXTUAL-CONVENTION from IMPORTS
3. Corrected 4 digit date code defined in RFC2578
4. heRFSwitchWaitToRestoreTime is changed to Integer32 instead of INTEGER
5. Corrected object type definition in HeRFSwitchInputEntry sequence
6. Added double quote at the end of heRFSwitchInputExternalControl
description
7. Changed Rf to RF
8. Changed OID number of heRFSwitchMIBCompliances to 1 instead of 2
9. Changed the text description of SNMPv2 to SNMP for
heRFSwitchBasicCompliance MODULE-COMPLIANCE"
REVISION "200309110000Z"
DESCRIPTION
" Change Log:
1. Filled in SCTE number 94-2
2. Fixed all compile errors
3. Defined heRFSwitchInputIndex in the input entry sequence
4. Defined heRFSwitchOutputIndex in the output entry sequence"
REVISION "200305290000Z"
DESCRIPTION
"The MIB module for the HMS HE RF Switch module
entities.
This MIB module is for representing RF
switch equipment present in the headend (or indoor)
and is supported by a SNMP agent.
This MIB is limited in its scope and intended to
describe an A-B (2 input and 1 output) or a crossbar
RF switch. Up to 2 RF inputs and 2 outputs
are supported. Any devices with more than 2 RF
inputs or outputs shall be covered by another MIB.
This MIB does not intend to dictate all of the nuances
involved in changing control settings (automatic or
manual mode, changing switch controls in each possible
mode combination). The most common desired behaviors
are noted but specific switch operation and behavior
are left to the RF switch vendors.
Not all control enumerations must be supported. This
is noted in the variables that have optional
enumerations.
Refer to the associated notes for information on what
SNMP responses should be returned for unsupported
enumerations."
::= { heRFSwitchGroup 1 }
heRFSwitchMIBObjects OBJECT IDENTIFIER ::= { heRFSwitchMIB 1}
-- Every RF switch is modeled by the tables presented
-- in this MIB module. These tables extend the entPhysicalTable
-- according to RFC 2737. The extension index entPhysicalIndex uniquely
-- identifies the RF switch.
-- Every RF switch is also modeled by the following tables:
-- entPhysicalEntry - 1 row; (defined in document: RFC2737)
-- heCommonEntry - 1 row. (defined in document: HMS111)
-- Every RF switch module will have its alarms modeled by the table:
-- propertyEntry - x rows; (defined in document: HMS026)
-- (where x is the nos. of alarmable analog properties supported
-- by the RF switch)
-- discretePropertyEntry - y rows; (defined in document: HMS026)
-- (where y is the nos. of alarmable digital properties supported by
-- the RF switch)
-- Every RF switch module will have a list of currently active
-- alarms modeled by the table:
-- currentAlarmEntry - z rows; (defined in document: HMS026)
-- (where z is the nos. of current active alarms in the RF
-- switch)
-- Thus, an A-B RF switch (2 RF inputs and one RF output)
-- will be represented by one row in entPhysicalTable, one row in
-- heCommonTable, one row in heRFSwitchUnitTable, two rows in
-- heRFSwitchInputTable and one row in heRFSwitchOutputTable.
-- Additionally, a crossbar RF switch (2 inputs and 2 outputs)
-- will be represented by one row in entPhysicalTable, one row in
-- heCommonTable, one row in heRFSwitchUnitTable, two rows
-- in heRFSwitchInputTable and two rows in heRFSwitchOutputTable.
-- Correlation of outputs and inputs are indicated by the heRFSwitchState
-- variable. Correlation of physical inputs and outputs to
-- heRFSwitchInputTable and heRFSwitchOutputTables rows is indicated
-- by the heRFSwitchInputDescription and heRFSwitchOutputDescription
-- variables.
-- the RF Switch Unit Table
heRFSwitchUnitTable OBJECT-TYPE
SYNTAX SEQUENCE OF HeRFSwitchUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about RF Switch used
in an indoor environment."
::= { heRFSwitchMIBObjects 1 }
heRFSwitchUnitEntry OBJECT-TYPE
SYNTAX HeRFSwitchUnitEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each RF switch."
INDEX { entPhysicalIndex }
::= { heRFSwitchUnitTable 1 }
HeRFSwitchUnitEntry ::= SEQUENCE
{
heRFSwitchMode INTEGER,
heRFSwitchControl INTEGER,
heRFSwitchRevertEnable HeOnOffControl,
heRFSwitchState INTEGER,
heRFSwitchFailoverStatus HeFaultStatus,
heRFSwitchBothInputStatus HeFaultStatus,
heRFSwitchHysteresis HeTenthdB,
heRFSwitchWaitToRestoreTime Integer32,
heRFSwitchSensorMode INTEGER
}
heRFSwitchMode OBJECT-TYPE
SYNTAX INTEGER {
automatic(1),
manual(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls and/or reports the switching mode. If
automatic(1), the RF switch will evaluate the RF
input status and make the decision to affect the switch state.
If set to manual(2), the RF switch will not affect the
switch state itself."
::= { heRFSwitchUnitEntry 1 }
heRFSwitchControl OBJECT-TYPE
SYNTAX INTEGER {
pathA(1),
pathB(2),
cross(3),
bar(4),
bothA(5),
bothB(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Sets the intended state of the RF Switch. The effect
of this control will depend on the value of heRFSwitchMode.
If heRFSwitchMode is set to automatic, the value this
control is set to will be the preferred setting. If it is
set to manual, the switch will assume this setting. Actual
switch operation while changing switch control value(s)
is up to the equipment vendor. For example, if the switch
is in manual mode and the operator tries to connect the
output to an invalid input, the switch may or may
not change state.
Not all enumerations must be supported. For example, an
A-B RF switch may support only the pathA and pathB
enumerations while a cross-bar switch may support cross,
bar, bothA or bothB or only cross and bar but not pathA
and pathB enumerations. See the note below about the
expected SNMP response.
A value pathA(1) connects the switch output to side A
(first input) of the switch. This enumeration is intended
for use by an A-B switch.
A value pathB(2) connects the switch output to side B
(second input) of the switch. This enumeration is intended
for use by an A-B switch.
A value cross(3) connects the switch outputs to the inputs
as follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to
side A (first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bar(4) connects the switch outputs to the inputs as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to
side B (second or alternate) input.
This enumeration is intended for use by a cross-bar switch.
A value bothA(5) connects the switch outputs to the inputs as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to
side A (first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bothB(6) connects the switch outputs to the inputs
as follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to
side B (second or alternate) input.
This enumeration is intended for use by a cross-bar switch.
*** IMPORTANT ***
It is NOT required that an RF switch support all
enumerations. A SET request for an unsupported value shall
yield a badValue(3) error by an SNMPv1 agent or an
inconsistentValue(12) by an SNMPv2 agent."
::= { heRFSwitchUnitEntry 2 }
heRFSwitchRevertEnable OBJECT-TYPE
SYNTAX HeOnOffControl
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This controls the use of revert switching.
If set to on, the switch will attempt to go back to the
preferred settings indicated by heRFSwitchControl if
heRFSwitchMode is set to automatic, and the input status
of the preferred input is normal. The switch will not
attempt to revert to the settings indicated by
heRFSwitchControl until heRFSwitchWaitToRestoreTime
(if supported) has expired since the preferred input was
restored to normal levels.
If set to off, the switch will not attempt to go back to
the preferred settings indicated by heRFSwitchControl if
heRFSwitchMode is set to automatic, and the input status
of the preferred input is normal.
"
::= { heRFSwitchUnitEntry 3 }
heRFSwitchState OBJECT-TYPE
SYNTAX INTEGER {
pathA(1),
pathB(2),
cross(3),
bar(4),
bothA(5),
bothB(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Reports the state of the RF Switch. Not all enumerations
must be supported. For example, an A-B RF switch may
support only the pathA and pathB enumerations while a
cross-bar switch may support cross, bar, bothA or bothB or
only cross and bar but not pathA and pathB enumerations.
A value pathA(1) indicates that the switch output is being
fed by side A (first input) of the switch. This enumeration
is intended for use by an A-B switch.
A value pathB(2) indicates that the switch output is being
fed by side B (second input) of the switch. This enumeration
is intended for use by an A-B switch.
A value cross(3) indicates that the switch outputs are fed as
follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to side A
(first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bar(4) indicates that the switch outputs are fed as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to side B
(second or alternate) input.
This enumeration is intended for use by a cross-bar switch.
A value bothA(5) indicates that the switch outputs are fed as
follows:
Side A (first or primary) output is connected to side A
(first or primary) input.
Side B (second or alternate) output is connected to side A
(first or primary) input.
This enumeration is intended for use by a cross-bar switch.
A value bothB(6) indicates that the switch outputs are fed as
follows:
Side A (first or primary) output is connected to side B
(second or alternate) input.
Side B (second or alternate) output is connected to side B
(second or alternate) input.
This enumeration is intended for use by a cross-bar switch."
::= { heRFSwitchUnitEntry 4 }
heRFSwitchFailoverStatus OBJECT-TYPE
SYNTAX HeFaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integral status of both inputs.
A value is fault(2), if current switch state heRFSwitchState
is different than the preferred setting heRFSwitchControl,
otherwise, it is normal(1).
This object must provide for the alarm management capabilities
with a corresponding entry in the discretePropertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (HMS026).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { heRFSwitchUnitEntry 5 }
heRFSwitchBothInputStatus OBJECT-TYPE
SYNTAX HeFaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integral status of both inputs.
A value is fault(2), if both input levels are below
the nominal value; otherwise, it is normal(1).
This object must provide for the alarm management capabilities
with a corresponding entry in the discretePropertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (HMS026).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { heRFSwitchUnitEntry 6 }
heRFSwitchHysteresis OBJECT-TYPE
SYNTAX HeTenthdB (-20..20)
UNITS "0.1 dB"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls switch input hysteresis amount. The amount of hysteresis
used and the ability to change it is to be determined by
the vendor."
::= { heRFSwitchUnitEntry 7 }
heRFSwitchWaitToRestoreTime OBJECT-TYPE
SYNTAX Integer32
UNITS "1 sec"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls hysteresis time in sec.
If in automatic switching mode and revert mode is enabled,
a switch back to the original side will be delayed for
the time specified by this object."
::= { heRFSwitchUnitEntry 8 }
heRFSwitchSensorMode OBJECT-TYPE
SYNTAX INTEGER {
internal (1),
external (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls what source will be used for determining input
status:
A value of internal(1) causes the internal RF detection
circuitry to be used.
A value of external(2) will use heRFSwitchInputExternalControl
to determine input status.
"
::= { heRFSwitchUnitEntry 9 }
-- the RF Switch Input Table
heRFSwitchInputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HeRFSwitchInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each RF Switch
input used in an indoor environment."
::= { heRFSwitchMIBObjects 2 }
heRFSwitchInputEntry OBJECT-TYPE
SYNTAX HeRFSwitchInputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each RF switch input."
INDEX { entPhysicalIndex, heRFSwitchInputIndex }
::= { heRFSwitchInputTable 1 }
HeRFSwitchInputEntry ::= SEQUENCE
{
heRFSwitchInputIndex Unsigned32,
heRFSwitchInputRFLevel HeTenthdBmV,
heRFSwitchSetInputPowerThreshold HeTenthdBmV,
heRFSwitchInputStatus HeFaultStatus,
heRFSwitchInputDescription DisplayString,
heRFSwitchInputExternalControl HeFaultStatus
}
heRFSwitchInputIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index number corresponding to the RF Input."
::= { heRFSwitchInputEntry 1 }
heRFSwitchInputRFLevel OBJECT-TYPE
SYNTAX HeTenthdBmV
UNITS "0.1 dBmV"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The measured RF input power for the RF switch."
::= { heRFSwitchInputEntry 2 }
heRFSwitchSetInputPowerThreshold OBJECT-TYPE
SYNTAX HeTenthdBmV
UNITS "0.1 dBmV"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Input power switchover point for this input."
::= { heRFSwitchInputEntry 3 }
heRFSwitchInputStatus OBJECT-TYPE
SYNTAX HeFaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The integral status of the input.
A value is fault(2), if the input levels are not in
the nominal range; otherwise, it is normal(1).
This object must provide for the alarm management capabilities
with a corresponding entry in the discretePropertyTable of
SCTE-HMS-PROPERTY-MIB (HMS026).
An alarm shall be recorded as an entry in the currentAlarmTable
of SCTE-HMS-PROPERTY-MIB (HMS026).
A log record shall be added as an entry in the heCommonLogTable.
An heCommonAlarmEvent notification shall be sent."
::= { heRFSwitchInputEntry 4 }
heRFSwitchInputDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the switch input port. The description text is
to be determined by the equipment manufacturer. For example,
Input A or Side B."
::= { heRFSwitchInputEntry 5 }
heRFSwitchInputExternalControl OBJECT-TYPE
SYNTAX HeFaultStatus
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is an external control signal that indicates the status
of the associated input.
A value is fault(2), if the external control signal level is not in
the nominal range; otherwise, it is normal(1)."
::= { heRFSwitchInputEntry 6 }
-- the RF Switch Output Table
heRFSwitchOutputTable OBJECT-TYPE
SYNTAX SEQUENCE OF HeRFSwitchOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing information about each RF Switch
output used in an indoor environment."
::= { heRFSwitchMIBObjects 3 }
heRFSwitchOutputEntry OBJECT-TYPE
SYNTAX HeRFSwitchOutputEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of information about each RF switch output."
INDEX { entPhysicalIndex, heRFSwitchOutputIndex }
::= { heRFSwitchOutputTable 1 }
HeRFSwitchOutputEntry ::= SEQUENCE
{
heRFSwitchOutputIndex Unsigned32,
heRFSwitchOutputDescription DisplayString
}
heRFSwitchOutputIndex OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index number corresponding to the RF Output."
::= { heRFSwitchOutputEntry 1 }
heRFSwitchOutputDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A description of the switch output port. The description text
is to be determined by the equipment manufacturer. For example,
Output A or Seconday Output."
::= { heRFSwitchOutputEntry 2 }
-- conformance information
heRFSwitchMIBConformance OBJECT IDENTIFIER ::= { heRFSwitchMIB 2 }
heRFSwitchMIBCompliances OBJECT IDENTIFIER ::= { heRFSwitchMIBConformance 1 }
heRFSwitchMIBGroups OBJECT IDENTIFIER ::= { heRFSwitchMIBConformance 2 }
heRFSwitchBasicCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for SNMP HMS Headend RF
Switch entities which implement the SNMP
heRFSwitchMIB."
MODULE -- this module
MANDATORY-GROUPS { heRFSwitchUnitMandatoryGroup,
heRFSwitchInputMandatoryGroup,
heRFSwitchOutputMandatoryGroup
}
::= { heRFSwitchMIBCompliances 1 }
heRFSwitchUnitMandatoryGroup OBJECT-GROUP
OBJECTS {
heRFSwitchMode,
heRFSwitchControl,
heRFSwitchRevertEnable,
heRFSwitchState,
heRFSwitchFailoverStatus
}
STATUS current
DESCRIPTION
"The main group defines heRFSwitchUnitTable objects which
are mandatory to all indoor RF switch modules."
::= { heRFSwitchMIBGroups 1 }
heRFSwitchInputMandatoryGroup OBJECT-GROUP
OBJECTS {
heRFSwitchInputStatus,
heRFSwitchInputDescription
}
STATUS current
DESCRIPTION
"The main group defines heRFSwitchInputTable objects which
are mandatory to all indoor RF switch modules."
::= { heRFSwitchMIBGroups 2 }
heRFSwitchOutputMandatoryGroup OBJECT-GROUP
OBJECTS {
heRFSwitchOutputDescription
}
STATUS current
DESCRIPTION
"The main group defines heRFSwitchOutputTable objects which
are mandatory to all indoor RF switch modules."
::= { heRFSwitchMIBGroups 3 }
heRFSwitchUnitGroup OBJECT-GROUP
OBJECTS {
heRFSwitchBothInputStatus,
heRFSwitchHysteresis,
heRFSwitchWaitToRestoreTime,
heRFSwitchSensorMode
}
STATUS current
DESCRIPTION
"The collection of heRFSwitchUnitTable objects which are used to
represent the indoor RF switch module."
::= { heRFSwitchMIBGroups 4 }
heRFSwitchInputGroup OBJECT-GROUP
OBJECTS {
heRFSwitchInputRFLevel,
heRFSwitchSetInputPowerThreshold,
heRFSwitchInputExternalControl
}
STATUS current
DESCRIPTION
"The collection of heRFSwitchInputTable objects which are used to
represent the indoor RF switch module."
::= { heRFSwitchMIBGroups 5 }
END