Observium_CE/mibs/riverdelta/RDN-PKTCABLE-GROUP-MIB

1875 lines
67 KiB
Plaintext

-- *****************************************************************
-- RDN-PKTCABLE-GROUP-MIB
-- Motorola BSR's Packet Cable MIB
--
-- Copyright (C) 2002, 2008 by Motorola, Inc.
-- All rights reserved.
-- *****************************************************************
RDN-PKTCABLE-GROUP-MIB DEFINITIONS ::= BEGIN
IMPORTS
riverdelta
FROM RDN-MIB
MODULE-IDENTITY,
NOTIFICATION-TYPE,
OBJECT-TYPE,
Integer32,
IpAddress
FROM SNMPv2-SMI
TruthValue,
MacAddress,
TEXTUAL-CONVENTION,
DisplayString
FROM SNMPv2-TC;
rdnPacketCableGroup MODULE-IDENTITY
LAST-UPDATED "200810060000Z" -- 06 October 2008
ORGANIZATION "Motorola"
CONTACT-INFO "Motorola
Customer Service
101 Tournament Drive
Horsham, PA 19044
US Tel: +1 888 944 4357
Int Tel: +1 215 323 0044
Fax: +1 215 323 1502
Email: CPSSupport@Motorola.com"
DESCRIPTION
"MIB module for Motorola PacketCable.
Copyright (C) 2002, 2008 by Motorola, Inc.
All rights reserved."
REVISION "200810060000Z" -- Oct 06, 2008
DESCRIPTION
"Added Differentiated Services Code Point(DSCP) to Motorola PacketCable.
Added rdnPktDQoSDscp, rdnPktMMDscp, rdnPktEMDscp and rdnPktESCccDscp."
REVISION "200808080000Z" -- 08 August 2008
DESCRIPTION
"Fixed this MIB MODULE'S description and
its revison history. Added Copyright Statement into
MIB modules's description."
REVISION "200710220000Z" -- Oct 22, 2007
DESCRIPTION
"Added rdnPktDQoSGateResReassign to rdnPktDQoSStatsEntry."
REVISION "200605240000Z" -- May 24, 2006
DESCRIPTION
"Added RKS trap support to Motorola PacketCable.
Added rdnPktEMRKSFailureTrapEnable."
REVISION "200605240000Z" -- May 24, 2006
DESCRIPTION
"Corrected the comments for rdnPktDQoSEmergencyPreemptTrap
mib object."
REVISION "200602150000Z" -- Feb 15, 2006
DESCRIPTION
"Added rdnPktDQoSEmergencyPreemptTrap mib object."
REVISION "200601240000Z" -- January 24, 2006
DESCRIPTION
"Add Preemption mib object to Motorola PacketCable."
REVISION "200311050000Z" -- November 5, 2003
DESCRIPTION
"Updated the CONTACT-INFO."
REVISION "200310240000Z" -- October 24, 2003
DESCRIPTION
"Changed MAX-ACCESS of the following objects from
read-only to not-accessible: rdnGateId,
rdnGateDirection, rdnPktDQosCopsHandle. Removed
object rdnGateID and replaced with rdnGateId.
Value of rdnGateDirection downstream(2) added."
REVISION "200305120000Z" -- May 12, 2003
DESCRIPTION
"Imported NOTIFICATION-TYPE from SNMPv2-SMI."
REVISION "200209060000Z"
DESCRIPTION
"Initial Version. "
::= { riverdelta 7 }
-- Textual Conventions
BcidDataArray ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"An array holds the Billing Correlation ID."
SYNTAX OCTET STRING (SIZE (0..24))
--
-- riverdelta PacketCable group
--
rdnPktDQoSConfigGroup OBJECT IDENTIFIER ::= { rdnPacketCableGroup 1 }
rdnPktDQoSCOPSStatus OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is used to enable/disable PacketCable DQoS feature.
When this object is set to FALSE(2), DQoS will be disabled."
::= { rdnPktDQoSConfigGroup 1 }
rdnPktDQoSCMTSIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An IP address can be configured for the CMTS. If that IP address
is configured, BSR will only accept a COPS connection destined
to that IP address. Example, loop back, HFC or network IP address."
::= { rdnPktDQoSConfigGroup 2 }
rdnPktDQoSPEPID OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An ASCII string to identify the CMTS. Default - Motorola CMTS."
::= { rdnPktDQoSConfigGroup 3 }
rdnPktDQoSClientAccpTimer OBJECT-TYPE
SYNTAX Integer32 (1..3600000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the Time that limits the CMTS to wait for
the Client Accept from the CMS/GC in milliseconds."
::= { rdnPktDQoSConfigGroup 4 }
rdnPktDQoST0Timer OBJECT-TYPE
SYNTAX Integer32 (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the period of time in seconds that a Gate
may be allocated without being authorized."
::= { rdnPktDQoSConfigGroup 5 }
rdnPktDQoST1Timer OBJECT-TYPE
SYNTAX Integer32 (1..3600)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the time in seconds that may elapse between
the authorization and commit. This provisioned value is only used
if the T1 value is not provided by the GC/CMS."
::= { rdnPktDQoSConfigGroup 6 }
rdnPktDQoST3Timer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Place holder"
::= { rdnPktDQoSConfigGroup 7 }
rdnPktDQoST6Timer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Place holder."
::= { rdnPktDQoSConfigGroup 8 }
rdnPktDQoSCopsTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the PacketCable COPS connection trap
should be generated. If its value is set to enabled(1),
then traps are generated. If the value is disabled(2),
then traps are not generated. By default, this object
has the value disabled(2).
"
::= { rdnPktDQoSConfigGroup 9 }
rdnPktDQoSResReqTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the PacketCable Resource Request trap
should be generated. If its value is set to enabled(1),
then traps are generated. If the value is disabled(2),
then traps are not generated. By default, this object
has the value disabled(2).
"
::= { rdnPktDQoSConfigGroup 10 }
rdnPktESTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the PacketCable ES status trap
should be generated. If its value is set to enabled(1),
then traps are generated. If the value is disabled(2),
then traps are not generated. By default, this object
has the value disabled(2).
"
::= { rdnPktDQoSConfigGroup 11 }
rdnPktESEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the PacketCable ES feature is
enabled. If its value is set to enabled(1),
then Packet Cable ES functionality will operate based
on the information received in the Gate-Set message
from the CMS. If the value is disabled(2),
then the Packet Cable ES functionality will not
function according to the information received in the
Gate-Set message from the CMS. By default, this object
has the value enabled(1).
"
::= { rdnPktDQoSConfigGroup 12 }
rdnPktDQoSEmergencyTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the PacketCable Emergency Call trap
should be generated. If its value is set to enabled(1),
then traps are generated. If the value is disabled(2),
then traps are not generated. By default, this object
has the value disabled(2).
"
::= { rdnPktDQoSConfigGroup 13 }
rdnPktDQoSEmergencyPreemption OBJECT-TYPE
SYNTAX INTEGER {
disabled (0),
most-recent(1),
oldest(2),
random(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the PacketCable Emergency Preemption
is disabled or set to a specific option of dropping a
normal dqos voice call. If its value is set to most-recent(1),
the most-recent normal dqos voice call of that Service
Class is dropped when the bandwidth of the Emergency
Service Class has maxed out. The Preemption can only
occur if that Service Class has 'allowShared' turned
on. Otherwise, Preemption can not occur and thus, the
high priority call can not be completed. If the value
is oldest(2), the oldest normal dqos voice call is dropped.
If the value is random, random normal dqos voice call
is dropped. By default, this object has the value disabled(0).
"
::= { rdnPktDQoSConfigGroup 14 }
rdnPktEMRKSFailureTrapEnable OBJECT-TYPE
SYNTAX INTEGER { enabled(1), disabled(2) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Indicates whether the PacketCable EM RKS Failure trap
should be generated. If its value is set to enabled(1),
then the trap is generated. If the value is disabled(2),
then the trap is not generated. By default, this object
has the value disabled(2).
"
::= { rdnPktDQoSConfigGroup 15 }
rdnPktDQoSDscp OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The contents of the Differentiated Services Code Point(DSCP) for DQoS.
DSCP is intended to supersede the existing definitions
of the IPv4 TOS octet and the IPv6 Traffic Class octet.
By setting this value, DSCP will apply to all the DQoS
traffic IP header.
"
DEFVAL { 0 }
::= { rdnPktDQoSConfigGroup 16 }
rdnPktMMDscp OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The contents of the Differentiated Services Code Point(DSCP) for Multimedia.
DSCP is intended to supersede the exsiting definitions
of the IPv4 TOS octet and the IPv6 Traffic Class octet.
By setting this value, DSCP will apply to all the Multimedia
traffic IP header.
"
DEFVAL { 0 }
::= { rdnPktDQoSConfigGroup 17 }
rdnPktEMDscp OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The contents of the Differentiated Services Code Point(DSCP)
for Event Message and Electronic Surveillance Call
Data Connection(CDC).
DSCP is intended to supersede the existing definitions
of the IPv4 TOS octet and the IPv6 Traffic Class octet.
By setting this value, DSCP will apply to all the Event
Message traffic IP header and Electronic Surveillance
Call Data Connection traffic IP header.
"
DEFVAL { 0 }
::= { rdnPktDQoSConfigGroup 18 }
rdnPktESCccDscp OBJECT-TYPE
SYNTAX Integer32 (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The contents of the Differentiated Services Code Point(DSCP)
for Electronic Surveillance Call Content Connection(CCC).
DSCP is intended to supersede the existing definitions
of the IPv4 TOS octet and the IPv6 Traffic Class octet.
By setting this value, DSCP will apply to all the Electronic
Surveillance Call Content Connection traffic IP header.
"
DEFVAL { 0 }
::= { rdnPktDQoSConfigGroup 19 }
rdnGateStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RdnGateStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provide PacketCable statistics of DQoS gate."
::= { rdnPacketCableGroup 2 }
rdnGateStatsEntry OBJECT-TYPE
SYNTAX RdnGateStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry provides a set of statistics objects for DQoS gate."
INDEX { rdnGateId }
::= { rdnGateStatsTable 1 }
RdnGateStatsEntry ::= SEQUENCE
{
rdnGateId Integer32,
rdnGateStatsState INTEGER,
rdnGateStatsSubscriberIP IpAddress,
rdnGateStatsRKSPrimaryAddr IpAddress,
rdnGateStatsRKSPrimaryPort Integer32,
rdnGateStatsRKSSecondaryAddr IpAddress,
rdnGateStatsRKSSecondaryPort Integer32,
rdnGateStatsEventFlag Integer32,
rdnGateStatsBillingCorrelationID BcidDataArray,
rdnGateStatsDurationTime DisplayString,
rdnGateStatsSlotNum Integer32,
rdnGateStatsUpSfid Integer32,
rdnGateStatsDnSfid Integer32,
rdnGateStatsResourceID Integer32,
rdnGateStatsESCDCAddr IpAddress,
rdnGateStatsESCDCPort Integer32,
rdnGateStatsESFlag Integer32,
rdnGateStatsESCCCAddr IpAddress,
rdnGateStatsESCCCPort Integer32,
rdnGateStatsESCCCId Integer32
}
rdnGateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute is the identifier for allocated gate."
::= { rdnGateStatsEntry 1 }
rdnGateStatsState OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
start(1),
allocated(2),
authorized(3),
reserved(4),
-- remoteCommitted(5),
-- localCommitted(6),
committed(7),
committedRecovery(8),
numOfStates(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes current state
Idle(0),
Start(1),
Allocated(2),
Authorized(3),
Reserved(4),
RemoteCommitted(5),
LocalCommitted(6),
Committed(7)."
::= { rdnGateStatsEntry 2 }
rdnGateStatsSubscriberIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the IP address of MTA requesting the
gate. Issue:(IPV4 ONLY)"
::= { rdnGateStatsEntry 3 }
rdnGateStatsRKSPrimaryAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes Primary Record Keeping Server's IP
address, the record keeper to whom event records are sent."
::= { rdnGateStatsEntry 4 }
rdnGateStatsRKSPrimaryPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes Primary Record Keeping Server Port, the
port number for event records to be sent."
::= { rdnGateStatsEntry 5 }
rdnGateStatsRKSSecondaryAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes Secondary Record Keeping Server's IP
address, the record keeper to whom event records are sent."
::= { rdnGateStatsEntry 6 }
rdnGateStatsRKSSecondaryPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes Secondary Record Keeping Server Port,
the port number for event records to be sent."
::= { rdnGateStatsEntry 7 }
rdnGateStatsEventFlag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"0x01 - Batch Processing. If set the CMTS MUST accumulate event
records as part of a batch file and send to the Record Keeping
Server at periodic intervals. If clear the CMTS MUST send the
event records to the Record Keeping Serverin real-time."
::= { rdnGateStatsEntry 8 }
rdnGateStatsBillingCorrelationID OBJECT-TYPE
SYNTAX BcidDataArray
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is the identifier assigned by the CMS for all
records related to the session."
::= { rdnGateStatsEntry 9 }
rdnGateStatsDurationTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the time that gate was commited."
::= { rdnGateStatsEntry 10 }
rdnGateStatsSlotNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the CMTS slot number."
::= { rdnGateStatsEntry 11 }
rdnGateStatsUpSfid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the upstream SFID."
::= { rdnGateStatsEntry 12 }
rdnGateStatsDnSfid OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the downstream SFID."
::= { rdnGateStatsEntry 13 }
rdnGateStatsResourceID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute is an RSVP object that's used as an identifier
for future resource changes."
::= { rdnGateStatsEntry 14 }
rdnGateStatsESCDCAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the DF's IP address,
the DF to whom duplicated event messages are sent."
::= { rdnGateStatsEntry 15 }
rdnGateStatsESCDCPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the DF's Port for CDC, the
port number for duplicated event messages to be sent."
::= { rdnGateStatsEntry 16 }
rdnGateStatsESFlag OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"If bit 0 is set - DUP-Event. If set the CMTS MUST send a duplicate copy
of all event messages relate to this gate to the DF-IP-Address for
CDC (rdnGateStatsESCDCAddr). If bit 1 is set the CMTS MUST
send a duplicate copy of all packets matching the
classifier(s) fo this gate to the DF-IP-Address-for-CCC (rdnGateStatsESCCCAddr)."
::= { rdnGateStatsEntry 17 }
rdnGateStatsESCCCAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the DF's IP address for CCC,
the DF to whom duplicated classifier matched packets are sent."
::= { rdnGateStatsEntry 18 }
rdnGateStatsESCCCPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the DF's Port for CCC, the
port number for duplicated classifier matched packets to be sent."
::= { rdnGateStatsEntry 19 }
rdnGateStatsESCCCId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Identifier used to identify the intercept order to the Law
Enforcement Agency."
::= { rdnGateStatsEntry 20 }
rdnGateSpecTable OBJECT-TYPE
SYNTAX SEQUENCE OF RdnGateSpecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains DQoS Gate Specification statistics of
upstream and downstream."
::= { rdnPacketCableGroup 3 }
rdnGateSpecEntry OBJECT-TYPE
SYNTAX RdnGateSpecEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contain DQoS Gate Specification statistics of
the upstream or downstream."
INDEX { rdnGateId, rdnGateDirection }
::= { rdnGateSpecTable 1 }
RdnGateSpecEntry ::= SEQUENCE
{
rdnGateDirection INTEGER,
rdnGateSpecProtocol Integer32,
rdnGateSpecSourceIP IpAddress,
rdnGateSpecSourcePort Integer32,
rdnGateSpecDestIP IpAddress,
rdnGateSpecDestPort Integer32,
rdnGateSpecServiceFlowID Integer32,
rdnGateSpecFlags INTEGER,
rdnGateSpecSessionClass INTEGER,
rdnGateSpecDiffServCode Integer32,
rdnGateSpecT1Timer Integer32,
rdnGateSpecTokenBuckRate Integer32,
rdnGateSpecBuckSize Integer32,
rdnGateSpecPeakDataRate Integer32,
rdnGateSpecMinPoliceUnit Integer32,
rdnGateSpecMaxPacketSize Integer32,
rdnGateSpecReserveRate Integer32,
rdnGateSlackTerm Integer32
}
rdnGateDirection OBJECT-TYPE
SYNTAX INTEGER {
upstream(1),
downstream(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute describes the direction of the gate specification."
::= { rdnGateSpecEntry 2 }
rdnGateSpecProtocol OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the Protocol to match in the IP header."
::= { rdnGateSpecEntry 3 }
rdnGateSpecSourceIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the source IP V4 address, zero for no
match."
::= { rdnGateSpecEntry 4 }
rdnGateSpecSourcePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes source port. Zero for no match."
::= { rdnGateSpecEntry 5 }
rdnGateSpecDestIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the destination IP V4 address, zero for
no match."
::= { rdnGateSpecEntry 6 }
rdnGateSpecDestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes destination port. Zero for no match."
::= { rdnGateSpecEntry 7 }
rdnGateSpecServiceFlowID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes the service flow ID that maps to the
Gate. This value could be zero if a Gate is viewed prior to a
SFID being assigned to the Gate."
::= { rdnGateSpecEntry 8 }
rdnGateSpecFlags OBJECT-TYPE
SYNTAX INTEGER {
autoCommit(1),
commitNotAllowed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"autoCommit(1), resources Commit immediately upon reservation.
commitNotAllowed(2), CMTS ignores any COMMIT messages for the
gate."
::= { rdnGateSpecEntry 9 }
rdnGateSpecSessionClass OBJECT-TYPE
SYNTAX INTEGER {
unspecified(255),
normalPriority(1),
highPriority(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute identifies the proper admission control policy or
parameters to be applied for the gate.
unspecified (255),
normalPriority (1),
highPriority (2)."
::= { rdnGateSpecEntry 10 }
rdnGateSpecDiffServCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes Differentiated Services Code Point."
::= { rdnGateSpecEntry 11 }
rdnGateSpecT1Timer OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute describes Gate Transition timer in seconds, the
time limit between authorization and a commit."
::= { rdnGateSpecEntry 12 }
rdnGateSpecTokenBuckRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Token Bucket Rate, (r) 32 bit IEEE floating point number used in
Bandwidth Calculations. Specifies the token bucket that the traffic
conforms to. Part of TSpec."
::= { rdnGateSpecEntry 13 }
rdnGateSpecBuckSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Token Bucket Size (b) 32 bit IEEE floating point number used in
Bandwidth Calculations. Specifies the token bucket that the traffic
conforms ot. Part of TSpec."
::= { rdnGateSpecEntry 14 }
rdnGateSpecPeakDataRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Peak Data Rate (p) 32 bit IEEE floating point number used in
Bandwidth Calculations. Specifies the Peak Data Rate at which
the source sends traffic. Part of TSpec."
::= { rdnGateSpecEntry 15 }
rdnGateSpecMinPoliceUnit OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum Policed Unit (m) 32 bit integer. The smallest packet
size that the source generates, if asmaller packet is sent, it
will count as a packet of size m for the purpose fo policing.
Part of TSpec."
::= { rdnGateSpecEntry 16 }
rdnGateSpecMaxPacketSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Packet Size (M) 32 bit integer. Maximum packet size
(including IP and higher layer headers) that are generated by
the source. Part of TSpec."
::= { rdnGateSpecEntry 17 }
rdnGateSpecReserveRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Rate (R) 32 bit IEEE floating point integer. The amount of
bandwidth allocated to the flow. Must be greater than or equal
to (r) from the TSpec. Part of RSpec."
::= { rdnGateSpecEntry 18 }
rdnGateSlackTerm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Slack Term (S) 32 bit integer. Delay Bound part of RSpec."
::= { rdnGateSpecEntry 19 }
rdnPktCMSIpConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RdnPktCMSIpConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contain the IP address list of CMS/GC configuration."
::= { rdnPacketCableGroup 4 }
rdnPktCMSIpConfigEntry OBJECT-TYPE
SYNTAX RdnPktCMSIpConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"List of IP addresses for CMS/GC."
INDEX { rdnPktCMSIpAddressIndex }
::= {rdnPktCMSIpConfigTable 1 }
RdnPktCMSIpConfigEntry ::= SEQUENCE {
rdnPktCMSIpAddressIndex Integer32,
rdnPktCMSIpAddress IpAddress
}
rdnPktCMSIpAddressIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index to access rdnPktCMSIpAddress."
::= { rdnPktCMSIpConfigEntry 1 }
rdnPktCMSIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies an IP address of a CMS/GC: If not configured, CMTS
accepts any CMS IP Address.
NOTE: it is necessary to accept the TCP connection, and then
determine if the IP address can be used. If not the connection
is closed."
::= { rdnPktCMSIpConfigEntry 2 }
rdnPktDQoSStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF RdnPktDQoSStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains DQoS Gate statistics.
Note: Index is equal to COPS Handle plus one."
::= { rdnPacketCableGroup 6 }
rdnPktDQoSStatsEntry OBJECT-TYPE
SYNTAX RdnPktDQoSStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry contains DQoS Gate statistic data.
Note: Index is equal to COPS Handle plus one."
INDEX { rdnPktDQoSCopsHandle }
::= { rdnPktDQoSStatsTable 1 }
RdnPktDQoSStatsEntry ::= SEQUENCE {
rdnPktDQoSIpAddress IpAddress,
rdnPktDQoSCopsHandle Integer32,
rdnPktDQoSCopsStatus INTEGER,
rdnPktDQoSCopsConnected Integer32,
rdnPktDQoSCopsTerminated Integer32,
rdnPktDQoSCopsKASent Integer32,
rdnPktDQoSCopsKARcvd Integer32,
rdnPktDQoSKATimeout Integer32,
rdnPktDQoST0Timeout Integer32,
rdnPktDQoST1Timeout Integer32,
rdnPktDQoSGateAllocCount Integer32,
rdnPktDQoSGateAllocAckCount Integer32,
rdnPktDQoSGateAllocErrCount Integer32,
rdnPktDQoSGateSetCount Integer32,
rdnPktDQoSGateSetAckCount Integer32,
rdnPktDQoSGateSetErrCount Integer32,
rdnPktDQoSGateDeleteCount Integer32,
rdnPktDQoSGateDeleteAckCount Integer32,
rdnPktDQoSGateDeleteErrCount Integer32,
rdnPktDQoSGateInfoCount Integer32,
rdnPktDQoSGateInfoAckCount Integer32,
rdnPktDQoSGateInfoErrCount Integer32,
rdnPktDQoSGateOpenRcvd Integer32,
rdnPktDQoSGateOpenAckSent Integer32,
rdnPktDQoSGateOpenErrSent Integer32,
rdnPktDQoSGateCloseRcvd Integer32,
rdnPktDQoSGateCloseAckSent Integer32,
rdnPktDQoSGateCloseErrSent Integer32,
rdnPktDQoSGateOpenSent Integer32,
rdnPktDQoSGateOpenAckRcvd Integer32,
rdnPktDQoSGateOpenErrRcvd Integer32,
rdnPktDQoSGateCloseSent Integer32,
rdnPktDQoSGateCloseAckRcvd Integer32,
rdnPktDQoSGateCloseErrRcvd Integer32,
rdnPktDQoSGateOpenRetries Integer32,
rdnPktDQoSGateCloseRetries Integer32,
rdnPktDQoSGateOpenExhausted Integer32,
rdnPktDQoSGateCloseExhausted Integer32,
rdnPktDQoSCliOpenSent Integer32,
rdnPktDQoSCliAcceptReceived Integer32,
rdnPktDQoSRequestSent Integer32,
rdnPktDQoSCliCloseReceived Integer32,
rdnPktDQoSCliCloseSent Integer32,
rdnPktDQoSSsqReceived Integer32,
rdnPktDQoSSscSent Integer32,
rdnPktDQoSDrqSent Integer32,
rdnPktDQoST7Timeout Integer32,
rdnPktDQoST8Timeout Integer32,
rdnPktDQoSGateCmDel Integer32,
rdnPktDQoSGateCmDereg Integer32,
rdnPktDQoSGateAdminDel Integer32,
rdnPktDQoSGateResReassign Integer32
-- Future PCMM support
-- rdnPktDQoSMMGateSetCount Integer32,
-- rdnPktDQoSMMGateSetAckCount Integer32,
-- rdnPktDQoSMMGateSetErrCount Integer32,
-- rdnPktDQoSMMGateDeleteCount Integer32,
-- rdnPktDQoSMMGateDeleteAckCount Integer32,
-- rdnPktDQoSMMGateDeleteErrCount Integer32,
-- rdnPktDQoSMMGateInfoCount Integer32,
-- rdnPktDQoSMMGateInfoAckCount Integer32,
-- rdnPktDQoSMMGateInfoErrCount Integer32,
-- rdnPktDQoSMMGateReportStateCount Integer32,
-- rdnPktDQoSMMT1Timeout Integer32,
-- rdnPktDQoSMMT2Timeout Integer32,
-- rdnPktDQoSMMT3Timeout Integer32,
-- rdnPktDQoSMMT4Timeout Integer32,
-- rdnPktDQoSMMVolLimit Integer32,
-- rdnPktDQoSMMCmDereg Integer32,
-- rdnPktDQoSMMAdminDel Integer32
}
rdnPktDQoSIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains IP address of cms - used for debugging stats"
::= { rdnPktDQoSStatsEntry 1 }
rdnPktDQoSCopsHandle OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This entry contains cms handle id."
::= { rdnPktDQoSStatsEntry 2 }
rdnPktDQoSCopsStatus OBJECT-TYPE
SYNTAX INTEGER {
closed(0),
opening(1),
open(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains cm state."
::= { rdnPktDQoSStatsEntry 3 }
rdnPktDQoSCopsConnected OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains statistics of CMS connections."
::= { rdnPktDQoSStatsEntry 4 }
rdnPktDQoSCopsTerminated OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains statistics of the statistics of the CMS-CMTS
session close."
::= { rdnPktDQoSStatsEntry 5 }
rdnPktDQoSCopsKASent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of KA sending to the CMS."
::= { rdnPktDQoSStatsEntry 6 }
rdnPktDQoSCopsKARcvd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of KA received ."
::= { rdnPktDQoSStatsEntry 7 }
rdnPktDQoSKATimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of the expiration of the KA
timer."
::= { rdnPktDQoSStatsEntry 8 }
rdnPktDQoST0Timeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of the expiration of T0 timer."
::= { rdnPktDQoSStatsEntry 9 }
rdnPktDQoST1Timeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of the expiration of T1 timer."
::= { rdnPktDQoSStatsEntry 10 }
rdnPktDQoSGateAllocCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_CCM_GATE_ALLOC_CMD
message received."
::= { rdnPktDQoSStatsEntry 11 }
rdnPktDQoSGateAllocAckCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_CCM_GATE_ALLOC_ACK_CMD
message sent."
::= { rdnPktDQoSStatsEntry 12 }
rdnPktDQoSGateAllocErrCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of gate allocation error
message sent."
::= { rdnPktDQoSStatsEntry 13 }
rdnPktDQoSGateSetCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_CCM_GATE_SET_CMD
message received."
::= { rdnPktDQoSStatsEntry 14 }
rdnPktDQoSGateSetAckCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_CCM_GATE_SET_ACK_CMD
message sent."
::= { rdnPktDQoSStatsEntry 15 }
rdnPktDQoSGateSetErrCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of gate set error message
sent."
::= { rdnPktDQoSStatsEntry 16 }
rdnPktDQoSGateDeleteCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_CCM_GATE_DELETE_CMD
message received."
::= { rdnPktDQoSStatsEntry 17 }
rdnPktDQoSGateDeleteAckCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_CCM_GATE_DELETE_ACK_CMD
message sent."
::= { rdnPktDQoSStatsEntry 18 }
rdnPktDQoSGateDeleteErrCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of gate delete error message
sent."
::= { rdnPktDQoSStatsEntry 19 }
rdnPktDQoSGateInfoCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_CCM_GATE_INFO_CMD
message received."
::= { rdnPktDQoSStatsEntry 20 }
rdnPktDQoSGateInfoAckCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_CCM_GATE_INFO_ACK_CMD
message sent."
::= { rdnPktDQoSStatsEntry 21 }
rdnPktDQoSGateInfoErrCount OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of gate info error message
sent."
::= { rdnPktDQoSStatsEntry 22 }
rdnPktDQoSGateOpenRcvd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_OPEN_MSG_TYPE
message received."
::= { rdnPktDQoSStatsEntry 23 }
rdnPktDQoSGateOpenAckSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_OPEN_ACK_MSG
message sent."
::= { rdnPktDQoSStatsEntry 24 }
rdnPktDQoSGateOpenErrSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of gate open error message
message sent."
::= { rdnPktDQoSStatsEntry 25 }
rdnPktDQoSGateCloseRcvd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_CLOSE_MSG
received."
::= { rdnPktDQoSStatsEntry 26 }
rdnPktDQoSGateCloseAckSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_CLOSE_ACK_MSG
sent."
::= { rdnPktDQoSStatsEntry 27 }
rdnPktDQoSGateCloseErrSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of Gate Close Error message
sent."
::= { rdnPktDQoSStatsEntry 28 }
rdnPktDQoSGateOpenSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_OPEN_MSG sent."
::= { rdnPktDQoSStatsEntry 29 }
rdnPktDQoSGateOpenAckRcvd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_OPEN_ACK_MSG
received."
::= { rdnPktDQoSStatsEntry 30 }
rdnPktDQoSGateOpenErrRcvd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of Gate Open Error message
received."
::= { rdnPktDQoSStatsEntry 31 }
rdnPktDQoSGateCloseSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_CLOSE_MSG
sent."
::= { rdnPktDQoSStatsEntry 32 }
rdnPktDQoSGateCloseAckRcvd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_CLOSE_ACK_MSG
received."
::= { rdnPktDQoSStatsEntry 33 }
rdnPktDQoSGateCloseErrRcvd OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of Gate Close Error message
received."
::= { rdnPktDQoSStatsEntry 34 }
rdnPktDQoSGateOpenRetries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_OPEN_MSG_TYPE
sent when T5 expires."
::= { rdnPktDQoSStatsEntry 35 }
rdnPktDQoSGateCloseRetries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of DGM_GSM_GATE_CLOSE_MSG sent
when T5 expires. "
::= { rdnPktDQoSStatsEntry 36 }
rdnPktDQoSGateOpenExhausted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of gate message retry exhausted
with DGM_GSM_GATE_OPEN_MSG_TYPE."
::= { rdnPktDQoSStatsEntry 37 }
rdnPktDQoSGateCloseExhausted OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS obsolete
DESCRIPTION
"This entry contains the statistics of gate message retry exhausted
with DGM_GSM_GATE_CLOSE_MSG. "
::= { rdnPktDQoSStatsEntry 38 }
rdnPktDQoSCliOpenSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for Client Opens sent."
::= { rdnPktDQoSStatsEntry 39 }
rdnPktDQoSCliAcceptReceived OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for Client Accepts received."
::= { rdnPktDQoSStatsEntry 40 }
rdnPktDQoSRequestSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for Requests sent."
::= { rdnPktDQoSStatsEntry 41 }
rdnPktDQoSCliCloseReceived OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for Client Close received."
::= { rdnPktDQoSStatsEntry 42 }
rdnPktDQoSCliCloseSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for Client Close sent."
::= { rdnPktDQoSStatsEntry 43 }
rdnPktDQoSSsqReceived OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for SSQs received."
::= { rdnPktDQoSStatsEntry 44 }
rdnPktDQoSSscSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for SSCs sent."
::= { rdnPktDQoSStatsEntry 45 }
rdnPktDQoSDrqSent OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for DRQs sent."
::= { rdnPktDQoSStatsEntry 46 }
rdnPktDQoST7Timeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of the expiration of T7 timer."
::= { rdnPktDQoSStatsEntry 47 }
rdnPktDQoST8Timeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistics of the expiration of T8 timer."
::= { rdnPktDQoSStatsEntry 48 }
rdnPktDQoSGateCmDel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for Gate CM deleted."
::= { rdnPktDQoSStatsEntry 49 }
rdnPktDQoSGateCmDereg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic Gate CM de-registered."
::= { rdnPktDQoSStatsEntry 50 }
rdnPktDQoSGateAdminDel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for Gate Administrator Delete."
::= { rdnPktDQoSStatsEntry 51 }
rdnPktDQoSGateResReassign OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry contains the statistic for Gate Reservation Reassignment."
::= { rdnPktDQoSStatsEntry 52 }
--rdnPktDQoSMMGateSetCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Set count."
-- ::= { rdnPktDQoSStatsEntry 52 }
--rdnPktDQoSMMGateSetAckCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Set ACK count."
-- ::= { rdnPktDQoSStatsEntry 53 }
--rdnPktDQoSMMGateSetErrCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Set Error count."
-- ::= { rdnPktDQoSStatsEntry 54 }
--rdnPktDQoSMMGateDeleteCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Delete count."
-- ::= { rdnPktDQoSStatsEntry 55 }
--rdnPktDQoSMMGateDeleteAckCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Delete ACK count."
-- ::= { rdnPktDQoSStatsEntry 56 }
--rdnPktDQoSMMGateDeleteErrCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Delete Error count."
-- ::= { rdnPktDQoSStatsEntry 57 }
--rdnPktDQoSMMGateInfoCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Info count."
-- ::= { rdnPktDQoSStatsEntry 58 }
--rdnPktDQoSMMGateInfoAckCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Info ACK count."
-- ::= { rdnPktDQoSStatsEntry 59 }
--rdnPktDQoSMMGateInfoErrCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Info Error count."
-- ::= { rdnPktDQoSStatsEntry 60 }
--rdnPktDQoSMMGateReportStateCount OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Gate Report State count."
-- ::= { rdnPktDQoSStatsEntry 61 }
--rdnPktDQoSMMT1Timeout OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM T1 timeout."
-- ::= { rdnPktDQoSStatsEntry 62 }
--rdnPktDQoSMMT2Timeout OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM T2 timeout."
-- ::= { rdnPktDQoSStatsEntry 63 }
--rdnPktDQoSMMT3Timeout OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM T3 timeout."
-- ::= { rdnPktDQoSStatsEntry 64 }
--rdnPktDQoSMMT4Timeout OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM T4 timeout."
-- ::= { rdnPktDQoSStatsEntry 65 }
--rdnPktDQoSMMVolLimit OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Volume Limit reached."
-- ::= { rdnPktDQoSStatsEntry 66 }
--rdnPktDQoSMMCmDereg OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM CM deregisters."
-- ::= { rdnPktDQoSStatsEntry 67 }
--rdnPktDQoSMMAdminDel OBJECT-TYPE
-- SYNTAX Integer32
-- MAX-ACCESS read-only
-- STATUS current
-- DESCRIPTION
-- "This entry contains the statistic for PCMM Administrator delete."
-- ::= { rdnPktDQoSStatsEntry 68 }
-- traps
rdnPktDQoSNotificationObject OBJECT IDENTIFIER ::= { rdnPacketCableGroup 7 }
rdnPktDQoSCopsReason OBJECT-TYPE
SYNTAX INTEGER {
copsConnectionEstablished(1),
cantEstablishCopsConnection(2),
unauthorizedCms(3),
copsConnectionClosed(4),
copsConnectionDisconnected(5),
keepAliveFailure(6)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the rdnPktDQoSCopsTrap reason code
1 = The CMTS COPS connection to the CMS/GC is established.
specified in the rdnPktDQoSCopsCmsIpAddr field.
2 = Can't establish the COPS connection with the IP address
specified in the rdnPktDQoSCopsCmsIpAddr field.
3 = The CMS attempting to make the COPS connection is not
authorized to make the connection. The IP address is
specified in the rdnPktDQoSCopsCmsIpAddr field.
4 = The CMTS COPS connection to the CMS/GC is closed. The
CMTS has received a ClientClose from the CMS/GC. The IP
address of the CMS/GC is specified in the
rdnPktDQoSCopsCmsIpAddr field.
5 = The CMTS COPS connection to the CMS/GC is disconnected.
The connection was administratively closed via a command
from the console of the CMTS. The IP address of the CMS/GC
is specified in the rdnPktDQoSCopsCmsIpAddr field.
6 = The CMTS has not received a Keep-Alive message from
the CMS/GC within the specified KA timer interval.
The IP address of the CMS/GC is specified in the
rdnPktDQoSCopsCmsIpAddr field."
::= { rdnPktDQoSNotificationObject 1 }
rdnPktDQoSCopsCmsIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the IP address of the CMS/GC associated with
the reason code for the rdnPktDQoSCopsTrap."
::= { rdnPktDQoSNotificationObject 2 }
rdnPktDQoSCopsCmsPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the TCP port number that the CMS/GC
is connected on. This is additional information associated
with the reason code for the rdnPktDQoSCopsTrap."
::= { rdnPktDQoSNotificationObject 3 }
rdnPktDQoSCopsCmsHandleId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the COPS handle ID associated with the
connection to the CMS/GC. This is additional information
associated with the reason code for the rdnPktDQoSCopsTrap."
::= { rdnPktDQoSNotificationObject 4 }
rdnPktDQoSResReqReason OBJECT-TYPE
SYNTAX INTEGER {
dsaReqResourceGreaterThanAuth(1),
dsaResReqWithoutGateId(2),
dsaResReqWithInvalidGateId(3),
dscReqResourceGreaterThanAuth(4),
dscResReqWithoutGateId(5),
dscResReqWithInvalidGateId(6)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the rdnPktDQoSResReqTrap reason code
1 = The MTA DSA-REQ has requested more resource than it has been
authorized. The MTA is identified by the CM's Mac address
as specified in the rdnPktDQoSResReqCmMacAddr field.
2 = The MTA DSA-REQ is requesting resource with an unknown
Gate ID.
3 = The MTA DSA-REA is requesting resource without including
a Gate ID.
4 = The MTA DSC-REQ has requested more resource than it has been
authorized. The MTA is identified by the CM's Mac address
as specified in the rdnPktDQoSResReqCmMacAddr field.
5 = The MTA DSC-REQ is requesting resource with an unknown
Gate ID.
6 = The MTA DSC-REA is requesting resource without including
a Gate ID."
::= { rdnPktDQoSNotificationObject 5 }
rdnPktDQoSCmMacAddr OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the CM's Mac address for the MTA it
is associated with. The reason code and this Mac address
provide the detailed information for the rdnPktDQoSResReqTrap."
::= { rdnPktDQoSNotificationObject 6 }
rdnPktDQoSEmergencyReason OBJECT-TYPE
SYNTAX INTEGER {
emergencyCallBeingRejected(1)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the rdnPktDQoSEmergencyTrap reason code
1 = Emergency Call is rejected due to insufficient bandwidth."
::= { rdnPktDQoSNotificationObject 7 }
rdnPktDQoSClassName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"An ASCII string to identify the Class Name"
::= { rdnPktDQoSNotificationObject 8 }
rdnPktDQoSGateId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This attribute is the identifier for allocated gate.
Refer to rdnGateId."
::= { rdnPktDQoSNotificationObject 9 }
rdnPktDQoSEmergencyPreemptReason OBJECT-TYPE
SYNTAX INTEGER {
emergencyPreemptedMostRecentCall(1),
emergencyPreemptedOldestCall(2),
emergencyPreemptedRandomCall(3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the rdnPktDQoSEmergencyPreempTrap reason code
1 = Emergency call preempted the most recent DQoS call.
2 = Emergency call preempted the oldest DQoS call.
3 = Emergency call preempted a random DQoS call."
::= { rdnPktDQoSNotificationObject 10 }
--
-- DQoS Notification Group
--
rdnPktDQoSNotificationTraps OBJECT IDENTIFIER ::= {rdnPacketCableGroup 8 }
rdnPktDQoSNotificationTrapsPrefix OBJECT IDENTIFIER ::= {rdnPktDQoSNotificationTraps 0 }
rdnPktDQoSCopsTrap NOTIFICATION-TYPE
OBJECTS { rdnPktDQoSCopsReason,
rdnPktDQoSCopsCmsIpAddr }
STATUS current
DESCRIPTION
"A PacketCable COPS connection status change to the CMS/GC has
occurred. The reason code and CMS/GC IP address provide
the detailed information regarding this trap."
::= { rdnPktDQoSNotificationTrapsPrefix 1 }
rdnPktDQoSResReqTrap NOTIFICATION-TYPE
OBJECTS { rdnPktDQoSResReqReason,
rdnPktDQoSCmMacAddr}
STATUS current
DESCRIPTION
"A PacketCable MTA resource request problem has occurred
(e.g., a problem while processing the DSA-REQ or DSC-REQ
was detected). The reason code, the Gate ID, and the CM
Mac address, provide detailed information regarding
this trap."
::= { rdnPktDQoSNotificationTrapsPrefix 2 }
rdnPktDQoSEmergencyTrap NOTIFICATION-TYPE
OBJECTS { rdnPktDQoSEmergencyReason,
rdnPktDQoSCmMacAddr,
rdnPktDQoSClassName,
rdnPktDQoSGateId}
STATUS current
DESCRIPTION
"A PacketCable Emergency call is rejected.
The reason code, and the CM Mac address, the gate direction,
the Channel ID, and the Gate Id provide detailed information
regarding this trap."
::= { rdnPktDQoSNotificationTrapsPrefix 3 }
rdnPktDQoSEmergencyPreemptTrap NOTIFICATION-TYPE
OBJECTS { rdnPktDQoSEmergencyPreemptReason,
rdnPktDQoSCmMacAddr,
rdnPktDQoSClassName,
rdnPktDQoSGateId}
STATUS current
DESCRIPTION
"A PacketCable Emergency call is preempted successfully.
The reason code, and the CM Mac address, the Service Class
Name and the Gate Id provide detailed information regarding
this trap."
::= { rdnPktDQoSNotificationTrapsPrefix 4 }
rdnPktESNotificationObject OBJECT IDENTIFIER ::= { rdnPacketCableGroup 9 }
rdnPktESReason OBJECT-TYPE
SYNTAX INTEGER {
cdcFailure(1)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the rdnPktESTrap reason code
1 = Their was no reply from the DF when attempting to send
Duplicated Event messages."
::= { rdnPktESNotificationObject 1 }
rdnPktESDFIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the IP address of the DF associated with
the reason code for the rdnPktESTrap."
::= { rdnPktESNotificationObject 2 }
rdnPktESDFPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the port number that the DF
is connected on. This is additional information associated
with the reason code for the rdnPktESTrap."
::= { rdnPktESNotificationObject 3 }
--
-- ES Notification Group
--
rdnPktESNotificationTraps OBJECT IDENTIFIER ::= {rdnPacketCableGroup 10 }
rdnPktESNotificationTrapsPrefix OBJECT IDENTIFIER ::= {rdnPktESNotificationTraps 0 }
rdnPktESTrap NOTIFICATION-TYPE
OBJECTS { rdnPktESReason,
rdnPktESDFIpAddr,
rdnPktESDFPortNum}
STATUS current
DESCRIPTION
"A PacketCable ES failure has occurred.
The reason code, DF IP address and port provide
the detailed information regarding this trap."
::= { rdnPktESNotificationTrapsPrefix 1 }
rdnPktRKSNotificationObject OBJECT IDENTIFIER ::= { rdnPacketCableGroup 11 }
rdnPktRKSReason OBJECT-TYPE
SYNTAX INTEGER {
retriesExhausted(1)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the rdnPktRKSTrap reason code
1 = RKS communications failure. Primary and secondary RKS retries exhausted."
::= { rdnPktRKSNotificationObject 1 }
rdnPktRKSTransID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the event message Transaction ID.
This is additional information associated with the reason code for
the rdnPktRKSTrap."
::= { rdnPktRKSNotificationObject 2 }
rdnPktRKSIPPrimary OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the IP address of the primary RKS.
This is additional information associated with the reason code
for the rdnPktRKSTrap."
::= { rdnPktRKSNotificationObject 3 }
rdnPktRKSPortPrimary OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the TCP port number of the primary RKS.
This is additional information associated with the reason code
for the rdnPktRKSTrap."
::= { rdnPktRKSNotificationObject 4 }
rdnPktRKSIPSecondary OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the IP address of the secondary RKS.
This is additional information associated with the reason code
for the rdnPktRKSTrap."
::= { rdnPktRKSNotificationObject 5 }
rdnPktRKSPortSecondary OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the TCP port number of the secondary RKS.
This is additional information associated with the reason code
for the rdnPktRKSTrap."
::= { rdnPktRKSNotificationObject 6 }
rdnPktRKSVersionID OBJECT-TYPE
SYNTAX INTEGER {
packetCable10(1),
packetCable11(2),
packetCableMultiMedia(3)
}
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"This entry contains the version ID of the RKS associated with the rdnPktRKSTrap.
1 = Packet Cable 1.0
2 = Packet Cable 1.1
3 = Packet Cable MultiMedia"
::= { rdnPktRKSNotificationObject 7 }
--
-- RKS Notification Group
--
rdnPktRKSNotificationTraps OBJECT IDENTIFIER ::= {rdnPacketCableGroup 12 }
rdnPktRKSNotificationTrapsPrefix OBJECT IDENTIFIER ::= {rdnPktRKSNotificationTraps 0 }
rdnPktDQoSRKSTrap NOTIFICATION-TYPE
OBJECTS { rdnPktRKSReason,
rdnPktRKSTransID,
rdnPktRKSIPPrimary,
rdnPktRKSPortPrimary,
rdnPktRKSIPSecondary,
rdnPktRKSPortSecondary,
rdnPktRKSVersionID}
STATUS current
DESCRIPTION
"There has been a communication failure to both the primary
and secondary Record Keeping Servers.
The reason code, the ID of the failed Transaction, primary
and secondary RKS IP address and port number, and the RKS
version type is provided."
::= { rdnPktRKSNotificationTrapsPrefix 1}
END