ENERGY-OBJECT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
NOTIFICATION-TYPE,
|
|
mib-2,
|
|
Integer32, Counter32, Unsigned32, TimeTicks
|
|
FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION, RowStatus, TimeInterval,
|
|
TimeStamp, TruthValue, StorageType
|
|
FROM SNMPv2-TC
|
|
MODULE-COMPLIANCE, NOTIFICATION-GROUP, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
OwnerString
|
|
FROM RMON-MIB
|
|
entPhysicalIndex
|
|
FROM ENTITY-MIB
|
|
PowerStateSet
|
|
FROM IANAPowerStateSet-MIB;
|
|
|
|
energyObjectMib MODULE-IDENTITY
|
|
LAST-UPDATED "201502090000Z" -- 9 February 2015
|
|
ORGANIZATION "IETF EMAN Working Group"
|
|
CONTACT-INFO
|
|
"WG charter:
|
|
http://datatracker.ietf.org/wg/eman/charter/
|
|
|
|
Mailing Lists:
|
|
General Discussion: eman@ietf.org
|
|
|
|
To Subscribe:
|
|
https://www.ietf.org/mailman/listinfo/eman
|
|
|
|
Archive:
|
|
http://www.ietf.org/mail-archive/web/eman
|
|
|
|
Editors:
|
|
Mouli Chandramouli
|
|
Cisco Systems, Inc.
|
|
Sarjapur Outer Ring Road
|
|
Bangalore 560103
|
|
India
|
|
Phone: +91 80 4429 2409
|
|
Email: moulchan@cisco.com
|
|
|
|
Brad Schoening
|
|
44 Rivers Edge Drive
|
|
Little Silver, NJ 07739
|
|
United States
|
|
Email: brad.schoening@verizon.net
|
|
|
|
Juergen Quittek
|
|
NEC Europe, Ltd.
|
|
NEC Laboratories Europe
|
|
Network Research Division
|
|
Kurfuersten-Anlage 36
|
|
Heidelberg 69115
|
|
Germany
|
|
Phone: +49 6221 4342-115
|
|
Email: quittek@neclab.eu
|
|
|
|
Thomas Dietz
|
|
NEC Europe, Ltd.
|
|
NEC Laboratories Europe
|
|
Network Research Division
|
|
Kurfuersten-Anlage 36
|
|
69115 Heidelberg
|
|
Germany
|
|
Phone: +49 6221 4342-128
|
|
Email: Thomas.Dietz@nw.neclab.eu
|
|
|
|
Benoit Claise
|
|
Cisco Systems, Inc.
|
|
De Kleetlaan 6a b1
|
|
Degem 1831
|
|
Belgium
|
|
Phone: +32 2 704 5622
|
|
Email: bclaise@cisco.com"
|
|
DESCRIPTION
|
|
"Copyright (c) 2015 IETF Trust and the persons identified as
|
|
authors of the code. All rights reserved.
|
|
|
|
Redistribution and use in source and binary forms, with or
|
|
without modification, is permitted pursuant to, and subject
|
|
to the license terms contained in, the Simplified BSD License
|
|
set forth in Section 4.c of the IETF Trust's Legal Provisions
|
|
Relating to IETF Documents
|
|
(http://trustee.ietf.org/license-info).
|
|
|
|
This MIB is used to monitor power and energy in
|
|
devices.
|
|
|
|
The tables eoMeterCapabilitiesTable and eoPowerTable
|
|
are a sparse extension of the eoTable from the
|
|
ENERGY-OBJECT-CONTEXT-MIB. As a requirement,
|
|
[RFC7461] SHOULD be implemented.
|
|
|
|
Module Compliance of ENTITY-MIB v4 with respect to
|
|
entity4CRCompliance MUST be supported which requires
|
|
implementation of 4 MIB objects: entPhysicalIndex,
|
|
entPhysicalClass, entPhysicalName and entPhysicalUUID."
|
|
REVISION "201502090000Z" -- 9 February 2015
|
|
DESCRIPTION
|
|
"Initial version, published as RFC 7460."
|
|
::= { mib-2 229 }
|
|
|
|
energyObjectMibNotifs OBJECT IDENTIFIER
|
|
::= { energyObjectMib 0 }
|
|
|
|
energyObjectMibObjects OBJECT IDENTIFIER
|
|
::= { energyObjectMib 1 }
|
|
|
|
energyObjectMibConform OBJECT IDENTIFIER
|
|
::= { energyObjectMib 2 }
|
|
|
|
-- Textual Conventions
|
|
|
|
UnitMultiplier ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Unit Multiplier is an integer value that represents
|
|
the IEEE 61850 Annex A units multiplier associated with
|
|
the integer units used to measure the power or energy.
|
|
|
|
For example, when used with eoPowerUnitMultiplier, -3
|
|
represents 10^-3 or milliwatts."
|
|
REFERENCE
|
|
"The International System of Units (SI), National
|
|
Institute of Standards and Technology, Spec. Publ. 330,
|
|
August 1991."
|
|
SYNTAX INTEGER {
|
|
yocto(-24), -- 10^-24
|
|
zepto(-21), -- 10^-21
|
|
atto(-18), -- 10^-18
|
|
femto(-15), -- 10^-15
|
|
pico(-12), -- 10^-12
|
|
nano(-9), -- 10^-9
|
|
micro(-6), -- 10^-6
|
|
milli(-3), -- 10^-3
|
|
units(0), -- 10^0
|
|
kilo(3), -- 10^3
|
|
mega(6), -- 10^6
|
|
giga(9), -- 10^9
|
|
tera(12), -- 10^12
|
|
peta(15), -- 10^15
|
|
exa(18), -- 10^18
|
|
zetta(21), -- 10^21
|
|
yotta(24) -- 10^24
|
|
}
|
|
|
|
-- Objects
|
|
|
|
eoMeterCapabilitiesTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EoMeterCapabilitiesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is useful for helping applications determine
|
|
the monitoring capabilities supported by the local
|
|
management agents. It is possible for applications to
|
|
know which tables are usable without going through a
|
|
trial-and-error process."
|
|
::= { energyObjectMibObjects 1 }
|
|
|
|
eoMeterCapabilitiesEntry OBJECT-TYPE
|
|
SYNTAX EoMeterCapabilitiesEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry describes the metering capability of an Energy
|
|
Object."
|
|
INDEX { entPhysicalIndex }
|
|
::= { eoMeterCapabilitiesTable 1 }
|
|
|
|
EoMeterCapabilitiesEntry ::= SEQUENCE {
|
|
eoMeterCapability BITS
|
|
}
|
|
|
|
eoMeterCapability OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
none(0),
|
|
powermetering(1), -- power measurement
|
|
energymetering(2), -- energy measurement
|
|
powerattributes(3) -- power attributes
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An indication of the energy-monitoring capabilities
|
|
supported by this agent. This object use a BITS syntax
|
|
and indicates the MIB groups supported by the probe. By
|
|
reading the value of this object, it is possible to
|
|
determine the MIB tables supported."
|
|
::= { eoMeterCapabilitiesEntry 1 }
|
|
|
|
eoPowerTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EoPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists Energy Objects."
|
|
::= { energyObjectMibObjects 2 }
|
|
|
|
eoPowerEntry OBJECT-TYPE
|
|
SYNTAX EoPowerEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry describes the power usage of an Energy Object."
|
|
INDEX { entPhysicalIndex }
|
|
::= { eoPowerTable 1 }
|
|
|
|
EoPowerEntry ::= SEQUENCE {
|
|
eoPower Integer32,
|
|
eoPowerNameplate Unsigned32,
|
|
eoPowerUnitMultiplier UnitMultiplier,
|
|
eoPowerAccuracy Integer32,
|
|
eoPowerMeasurementCaliber INTEGER,
|
|
eoPowerCurrentType INTEGER,
|
|
eoPowerMeasurementLocal TruthValue,
|
|
eoPowerAdminState PowerStateSet,
|
|
eoPowerOperState PowerStateSet,
|
|
eoPowerStateEnterReason OwnerString
|
|
}
|
|
|
|
eoPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the power measured for the Energy
|
|
Object. For alternating current, this value is obtained
|
|
as an average over fixed number of AC cycles. This value
|
|
is specified in SI units of watts with the magnitude of
|
|
watts (milliwatts, kilowatts, etc.) indicated separately
|
|
in eoPowerUnitMultiplier. The accuracy of the measurement
|
|
is specified in eoPowerAccuracy. The direction of power
|
|
flow is indicated by the sign on eoPower. If the Energy
|
|
Object is consuming power, the eoPower value will be
|
|
positive. If the Energy Object is producing power, the
|
|
eoPower value will be negative.
|
|
|
|
The eoPower MUST be less than or equal to the maximum
|
|
power that can be consumed at the Power State specified
|
|
by eoPowerState.
|
|
|
|
The eoPowerMeasurementCaliber object specifies how the
|
|
usage value reported by eoPower was obtained. The eoPower
|
|
value must report 0 if the eoPowerMeasurementCaliber is
|
|
'unavailable'. For devices that cannot measure or
|
|
report power, this option can be used."
|
|
::= { eoPowerEntry 1 }
|
|
|
|
eoPowerNameplate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the rated maximum consumption for
|
|
the fully populated Energy Object. The nameplate power
|
|
requirements are the maximum power numbers given in SI
|
|
watts and, in almost all cases, are well above the
|
|
expected operational consumption. Nameplate power is
|
|
widely used for power provisioning. This value is
|
|
specified in either units of watts or voltage and
|
|
current. The units are therefore SI watts or equivalent
|
|
|
|
Volt-Amperes with the magnitude (milliwatts, kilowatts,
|
|
etc.) indicated separately in eoPowerUnitMultiplier."
|
|
::= { eoPowerEntry 2 }
|
|
|
|
eoPowerUnitMultiplier OBJECT-TYPE
|
|
SYNTAX UnitMultiplier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of watts for the usage value in eoPower
|
|
and eoPowerNameplate."
|
|
::= { eoPowerEntry 3 }
|
|
|
|
eoPowerAccuracy OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "hundredths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a percentage value, in hundredths of a
|
|
percent, representing the assumed accuracy of the usage
|
|
reported by eoPower. For example, the value 1010 means
|
|
the reported usage is accurate to +/- 10.1 percent. This
|
|
value is zero if the accuracy is unknown or not
|
|
applicable based upon the measurement method.
|
|
|
|
ANSI and IEC define the following accuracy classes for
|
|
power measurement:
|
|
IEC 62053-22 60044-1 class 0.1, 0.2, 0.5, 1 3.
|
|
ANSI C12.20 class 0.2, 0.5"
|
|
::= { eoPowerEntry 4 }
|
|
|
|
eoPowerMeasurementCaliber OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unavailable(1) ,
|
|
unknown(2),
|
|
actual(3) ,
|
|
estimated(4),
|
|
static(5) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies how the usage value reported by
|
|
eoPower was obtained:
|
|
|
|
- unavailable(1): Indicates that the usage is not
|
|
available. In such a case, the eoPower value must be 0
|
|
for devices that cannot measure or report power this
|
|
|
|
option can be used.
|
|
|
|
- unknown(2): Indicates that the way the usage was
|
|
determined is unknown. In some cases, entities report
|
|
aggregate power on behalf of another device. In such
|
|
cases it is not known whether the usage reported is
|
|
actual, estimated, or static.
|
|
|
|
- actual(3): Indicates that the reported usage was
|
|
measured by the entity through some hardware or direct
|
|
physical means. The usage data reported is not estimated
|
|
or static but is the measured consumption rate.
|
|
|
|
- estimated(4): Indicates that the usage was not
|
|
determined by physical measurement. The value is a
|
|
derivation based upon the device type, state, and/or
|
|
current utilization using some algorithm or heuristic. It
|
|
is presumed that the entity's state and current
|
|
configuration were used to compute the value.
|
|
|
|
- static(5): Indicates that the usage was not determined
|
|
by physical measurement, algorithm, or derivation. The
|
|
usage was reported based upon external tables,
|
|
specifications, and/or model information. For example, a
|
|
PC Model X draws 200W, while a PC Model Y draws 210W."
|
|
::= { eoPowerEntry 5 }
|
|
|
|
eoPowerCurrentType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ac(1),
|
|
dc(2),
|
|
unknown(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the eoPower for the
|
|
Energy Object reports alternating current 'ac', direct
|
|
current 'dc', or that the current type is unknown."
|
|
::= { eoPowerEntry 6 }
|
|
|
|
eoPowerMeasurementLocal OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the source of power measurement
|
|
and can be useful when modeling the power usage of
|
|
|
|
attached devices. The power measurement can be performed
|
|
by the entity itself or the power measurement of the
|
|
entity can be reported by another trusted entity using a
|
|
protocol extension. A value of true indicates the
|
|
measurement is performed by the entity, whereas false
|
|
indicates that the measurement was performed by another
|
|
entity."
|
|
::= { eoPowerEntry 7 }
|
|
|
|
eoPowerAdminState OBJECT-TYPE
|
|
SYNTAX PowerStateSet
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the desired Power State and the
|
|
Power State Set for the Energy Object. Note that other(0)
|
|
is not a Power State Set and unknown(255) is not a Power
|
|
State as such, but simply an indication that the Power
|
|
State of the Energy Object is unknown.
|
|
Possible values of eoPowerAdminState within the Power
|
|
State Set are registered at IANA.
|
|
A current list of assignments can be found at
|
|
<http://www.iana.org/assignments/power-state-sets>"
|
|
::= { eoPowerEntry 8 }
|
|
|
|
eoPowerOperState OBJECT-TYPE
|
|
SYNTAX PowerStateSet
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the current operational Power
|
|
State and the Power State Set for the Energy Object.
|
|
other(0) is not a Power State Set and unknown(255) is not
|
|
a Power State as such, but simply an indication that the
|
|
Power State of the Energy Object is unknown.
|
|
|
|
Possible values of eoPowerOperState within the Power
|
|
State Set are registered at IANA. A current list of
|
|
assignments can be found at
|
|
<http://www.iana.org/assignments/power-state-sets>"
|
|
::= { eoPowerEntry 9 }
|
|
|
|
eoPowerStateEnterReason OBJECT-TYPE
|
|
SYNTAX OwnerString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This string object describes the reason for the
|
|
|
|
eoPowerAdminState transition. Alternatively, this string
|
|
may contain with the entity that configured this Energy
|
|
Object to this Power State."
|
|
DEFVAL { "" }
|
|
::= { eoPowerEntry 10 }
|
|
|
|
eoPowerStateTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EoPowerStateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table enumerates the maximum power usage, in watts,
|
|
for every single supported Power State of each Energy
|
|
Object.
|
|
|
|
This table has cross-reference with the eoPowerTable,
|
|
containing rows describing each Power State for the
|
|
corresponding Energy Object. For every Energy Object in
|
|
the eoPowerTable, there is a corresponding entry in this
|
|
table."
|
|
::= { energyObjectMibObjects 3 }
|
|
|
|
eoPowerStateEntry OBJECT-TYPE
|
|
SYNTAX EoPowerStateEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A eoPowerStateEntry extends a corresponding
|
|
eoPowerEntry. This entry displays max usage values at
|
|
every single possible Power State supported by the Energy
|
|
Object.
|
|
For example, given the values of a Energy Object
|
|
corresponding to a maximum usage of 0 W at the
|
|
state emanmechoff, 8 W at state 6 (ready), 11 W at state
|
|
emanmediumMinus, and 11 W at state emanhigh:
|
|
|
|
State MaxUsage Units
|
|
emanmechoff 0 W
|
|
emansoftoff 0 W
|
|
emanhibernate 0 W
|
|
emansleep 0 W
|
|
emanstandby 0 W
|
|
emanready 8 W
|
|
emanlowMinus 8 W
|
|
emanlow 11 W
|
|
emanmediumMinus 11 W
|
|
emanmedium 11 W
|
|
emanhighMinus 11 W
|
|
|
|
emnanhigh 11 W
|
|
|
|
Furthermore, this table also includes the total time in
|
|
each Power State, along with the number of times a
|
|
particular Power State was entered."
|
|
INDEX { entPhysicalIndex, eoPowerStateIndex }
|
|
::= { eoPowerStateTable 1 }
|
|
|
|
EoPowerStateEntry ::= SEQUENCE {
|
|
eoPowerStateIndex PowerStateSet,
|
|
eoPowerStateMaxPower Integer32,
|
|
eoPowerStatePowerUnitMultiplier UnitMultiplier,
|
|
eoPowerStateTotalTime TimeTicks,
|
|
eoPowerStateEnterCount Counter32
|
|
}
|
|
|
|
eoPowerStateIndex OBJECT-TYPE
|
|
SYNTAX PowerStateSet
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the index of the Power State of
|
|
the Energy Object within a Power State Set. The semantics
|
|
of the specific Power State can be obtained from the
|
|
Power State Set definition."
|
|
::= { eoPowerStateEntry 1 }
|
|
|
|
eoPowerStateMaxPower OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the maximum power for the Energy
|
|
Object at the particular Power State. This value is
|
|
specified in SI units of watts with the magnitude of the
|
|
units (milliwatts, kilowatts, etc.) indicated separately
|
|
in eoPowerStatePowerUnitMultiplier. If the maximum power
|
|
is not known for a certain Power State, then the value is
|
|
encoded as 0xFFFFFFFF.
|
|
|
|
For Power States not enumerated, the value of
|
|
eoPowerStateMaxPower might be interpolated by using the
|
|
next highest supported Power State."
|
|
::= { eoPowerStateEntry 2 }
|
|
|
|
eoPowerStatePowerUnitMultiplier OBJECT-TYPE
|
|
SYNTAX UnitMultiplier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The magnitude of watts for the usage value in
|
|
eoPowerStateMaxPower."
|
|
::= { eoPowerStateEntry 3 }
|
|
|
|
eoPowerStateTotalTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the total time in hundredths
|
|
of a second that the Energy Object has been in this power
|
|
state since the last reset, as specified in the
|
|
sysUpTime."
|
|
::= { eoPowerStateEntry 4 }
|
|
|
|
eoPowerStateEnterCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates how often the Energy Object has
|
|
entered this power state, since the last reset of the
|
|
device as specified in the sysUpTime."
|
|
::= { eoPowerStateEntry 5 }
|
|
|
|
eoEnergyParametersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EoEnergyParametersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is used to configure the parameters for
|
|
energy measurement collection in the table eoEnergyTable.
|
|
This table allows the configuration of different
|
|
measurement settings on the same Energy Object.
|
|
Implementation of this table only makes sense for Energy
|
|
Objects that an eoPowerMeasurementCaliber of actual."
|
|
::= { energyObjectMibObjects 4 }
|
|
|
|
eoEnergyParametersEntry OBJECT-TYPE
|
|
SYNTAX EoEnergyParametersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry controls an energy measurement in
|
|
eoEnergyTable."
|
|
INDEX { entPhysicalIndex, eoEnergyParametersIndex }
|
|
::= { eoEnergyParametersTable 1 }
|
|
|
|
EoEnergyParametersEntry ::= SEQUENCE {
|
|
eoEnergyParametersIndex Integer32,
|
|
eoEnergyParametersIntervalLength TimeInterval,
|
|
eoEnergyParametersIntervalNumber Unsigned32,
|
|
eoEnergyParametersIntervalMode INTEGER,
|
|
eoEnergyParametersIntervalWindow TimeInterval,
|
|
eoEnergyParametersSampleRate Unsigned32,
|
|
eoEnergyParametersStorageType StorageType,
|
|
eoEnergyParametersStatus RowStatus
|
|
}
|
|
|
|
eoEnergyParametersIndex OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the index of the Energy Parameters
|
|
setting for collection of energy measurements for an
|
|
Energy Object. An Energy Object can have multiple
|
|
eoEnergyParametersIndex, depending on the capabilities of
|
|
the Energy Object"
|
|
::= { eoEnergyParametersEntry 2 }
|
|
|
|
eoEnergyParametersIntervalLength OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the length of time in hundredths
|
|
of a second over which to compute the average
|
|
eoEnergyConsumed measurement in the eoEnergyTable table.
|
|
The computation is based on the Energy Object's internal
|
|
sampling rate of power consumed or produced by the Energy
|
|
Object. The sampling rate is the rate at which the Energy
|
|
Object can read the power usage and may differ based on
|
|
device capabilities. The average energy consumption is
|
|
then computed over the length of the interval. The
|
|
default value of 15 minutes is a common interval used in
|
|
industry."
|
|
DEFVAL { 90000 }
|
|
::= { eoEnergyParametersEntry 3 }
|
|
|
|
eoEnergyParametersIntervalNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The number of intervals maintained in the eoEnergyTable.
|
|
Each interval is characterized by a specific
|
|
eoEnergyCollectionStartTime, used as an index to the
|
|
table eoEnergyTable. Whenever the maximum number of
|
|
entries is reached, the measurement over the new interval
|
|
replaces the oldest measurement. There is one exception
|
|
to this rule: when the eoEnergyMaxConsumed and/or
|
|
eoEnergyMaxProduced are in (one of) the two oldest
|
|
measurement(s), they are left untouched and the next
|
|
oldest measurement is replaced."
|
|
DEFVAL { 10 }
|
|
::= { eoEnergyParametersEntry 4 }
|
|
|
|
eoEnergyParametersIntervalMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
period(1),
|
|
sliding(2),
|
|
total(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A control object to define the mode of interval
|
|
calculation for the computation of the average
|
|
eoEnergyConsumed or eoEnergyProvided measurement in the
|
|
eoEnergyTable table.
|
|
|
|
A mode of period(1) specifies non-overlapping periodic
|
|
measurements.
|
|
|
|
A mode of sliding(2) specifies overlapping sliding
|
|
windows where the interval between the start of one
|
|
interval and the next is defined in
|
|
eoEnergyParametersIntervalWindow.
|
|
|
|
A mode of total(3) specifies non-periodic measurement.
|
|
In this mode only one interval is used as this is a
|
|
continuous measurement since the last reset. The value of
|
|
eoEnergyParametersIntervalNumber should be (1) one and
|
|
eoEnergyParametersIntervalLength is ignored."
|
|
::= { eoEnergyParametersEntry 5 }
|
|
|
|
eoEnergyParametersIntervalWindow OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The length of the duration window between the starting
|
|
time of one sliding window and the next starting time in
|
|
hundredths of seconds, used to compute the average of
|
|
eoEnergyConsumed, eoEnergyProvided measurements in the
|
|
eoEnergyTable table. This is valid only when the
|
|
eoEnergyParametersIntervalMode is sliding(2). The
|
|
eoEnergyParametersIntervalWindow value should be a
|
|
multiple of eoEnergyParametersSampleRate."
|
|
::= { eoEnergyParametersEntry 6 }
|
|
|
|
eoEnergyParametersSampleRate OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Milliseconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The sampling rate, in milliseconds, at which the Energy
|
|
Object should poll power usage in order to compute the
|
|
average eoEnergyConsumed, eoEnergyProvided measurements
|
|
in the table eoEnergyTable. The Energy Object should
|
|
initially set this sampling rate to a reasonable value,
|
|
i.e., a compromise between intervals that will provide
|
|
good accuracy by not being too long, but not so short
|
|
that they affect the Energy Object performance by
|
|
requesting continuous polling. If the sampling rate is
|
|
unknown, the value 0 is reported. The sampling rate
|
|
should be selected so that
|
|
eoEnergyParametersIntervalWindow is a multiple of
|
|
eoEnergyParametersSampleRate. The default value is one
|
|
second."
|
|
DEFVAL { 1000 }
|
|
::= { eoEnergyParametersEntry 7 }
|
|
|
|
eoEnergyParametersStorageType OBJECT-TYPE
|
|
SYNTAX StorageType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the storage type for this row."
|
|
DEFVAL { nonVolatile }
|
|
::= {eoEnergyParametersEntry 8 }
|
|
|
|
eoEnergyParametersStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The status of this row. The eoEnergyParametersStatus is
|
|
used to start or stop energy usage logging. An entry
|
|
status may not be active(1) unless all objects in the
|
|
entry have an appropriate value. If this object is not
|
|
equal to active, all associated usage-data logged into
|
|
the eoEnergyTable will be deleted. The data can be
|
|
destroyed by setting up the eoEnergyParametersStatus to
|
|
destroy."
|
|
::= {eoEnergyParametersEntry 9 }
|
|
|
|
eoEnergyTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF EoEnergyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table lists Energy Object energy measurements.
|
|
Entries in this table are only created if the
|
|
corresponding value of object eoPowerMeasurementCaliber
|
|
is active(3), i.e., if the power is actually metered."
|
|
::= { energyObjectMibObjects 5 }
|
|
|
|
eoEnergyEntry OBJECT-TYPE
|
|
SYNTAX EoEnergyEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry describing energy measurements."
|
|
INDEX { eoEnergyParametersIndex,
|
|
eoEnergyCollectionStartTime }
|
|
::= { eoEnergyTable 1 }
|
|
|
|
EoEnergyEntry ::= SEQUENCE {
|
|
eoEnergyCollectionStartTime TimeTicks,
|
|
eoEnergyConsumed Unsigned32,
|
|
eoEnergyProvided Unsigned32,
|
|
eoEnergyStored Unsigned32,
|
|
eoEnergyUnitMultiplier UnitMultiplier,
|
|
eoEnergyAccuracy Integer32,
|
|
eoEnergyMaxConsumed Unsigned32,
|
|
eoEnergyMaxProduced Unsigned32,
|
|
eoEnergyDiscontinuityTime TimeStamp
|
|
}
|
|
|
|
eoEnergyCollectionStartTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
UNITS "hundredths of a second"
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time (in hundredths of a second) since the
|
|
network management portion of the system was last
|
|
re-initialized, as specified in the sysUpTime RFC 3418.
|
|
This object specifies the start time of the energy
|
|
measurement sample."
|
|
REFERENCE
|
|
"RFC 3418: Management Information Base (MIB) for the
|
|
Simple Network Management Protocol (SNMP)"
|
|
::= { eoEnergyEntry 1 }
|
|
|
|
eoEnergyConsumed OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Watt-hours"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the energy consumed in units of
|
|
watt-hours for the Energy Object over the defined
|
|
interval. This value is specified in the common billing
|
|
units of watt-hours with the magnitude of watt-hours
|
|
kWh, MWh, etc.) indicated separately in
|
|
eoEnergyUnitMultiplier."
|
|
::= { eoEnergyEntry 2 }
|
|
|
|
eoEnergyProvided OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Watt-hours"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the energy produced in units of
|
|
watt-hours for the Energy Object over the defined
|
|
interval.
|
|
|
|
This value is specified in the common billing units of
|
|
watt-hours with the magnitude of watt-hours (kWh, MWh,
|
|
etc.) indicated separately in
|
|
eoEnergyUnitMultiplier."
|
|
::= { eoEnergyEntry 3 }
|
|
|
|
eoEnergyStored OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Watt-hours"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the difference of the energy
|
|
consumed and energy produced for an Energy Object in
|
|
units of watt-hours for the Energy Object over the
|
|
defined interval. This value is specified in the common
|
|
billing units of watt-hours with the magnitude of
|
|
watt-hours (kWh, MWh, etc.) indicated separately in
|
|
eoEnergyUnitMultiplier."
|
|
::= { eoEnergyEntry 4 }
|
|
|
|
eoEnergyUnitMultiplier OBJECT-TYPE
|
|
SYNTAX UnitMultiplier
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the magnitude of watt-hours for the
|
|
energy field in eoEnergyConsumed, eoEnergyProvided,
|
|
eoEnergyStored, eoEnergyMaxConsumed, and
|
|
eoEnergyMaxProduced."
|
|
::= { eoEnergyEntry 5 }
|
|
|
|
eoEnergyAccuracy OBJECT-TYPE
|
|
SYNTAX Integer32 (0..10000)
|
|
UNITS "hundredths of percent"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a percentage accuracy, in hundredths
|
|
of a percent, of Energy usage reporting. eoEnergyAccuracy
|
|
is applicable to all Energy measurements in the
|
|
eoEnergyTable.
|
|
|
|
For example, 1010 means the reported usage is accurate to
|
|
+/- 10.1 percent.
|
|
|
|
This value is zero if the accuracy is unknown."
|
|
::= { eoEnergyEntry 6 }
|
|
|
|
eoEnergyMaxConsumed OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Watt-hours"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the maximum energy observed in
|
|
eoEnergyConsumed since the monitoring started or was
|
|
reinitialized. This value is specified in the common
|
|
billing units of watt-hours with the magnitude of
|
|
watt-hours (kWh, MWh, etc.) indicated separately in
|
|
eoEnergyUnitMultiplier."
|
|
::= { eoEnergyEntry 7 }
|
|
|
|
eoEnergyMaxProduced OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Watt-hours"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the maximum energy ever observed in
|
|
eoEnergyEnergyProduced since the monitoring started. This
|
|
value is specified in the units of watt-hours with the
|
|
magnitude of watt-hours (kWh, MWh, etc.) indicated
|
|
separately in eoEnergyEnergyUnitMultiplier."
|
|
::= { eoEnergyEntry 8 }
|
|
|
|
eoEnergyDiscontinuityTime OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime RFC 3418 on the most recent
|
|
occasion at which any one or more of this entity's energy
|
|
counters in this table suffered a discontinuity:
|
|
eoEnergyConsumed, eoEnergyProvided or eoEnergyStored. If
|
|
no such discontinuities have occurred since the last
|
|
re-initialization of the local management subsystem, then
|
|
this object contains a zero value."
|
|
REFERENCE
|
|
"RFC 3418: Management Information Base (MIB) for the
|
|
Simple Network Management Protocol (SNMP)"
|
|
::= { eoEnergyEntry 9 }
|
|
|
|
-- Notifications
|
|
|
|
eoPowerEnableStatusNotification
|
|
OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls whether the system produces
|
|
notifications for eoPowerStateChange. A false value will
|
|
prevent these notifications from being generated."
|
|
DEFVAL { false }
|
|
::= { energyObjectMibNotifs 1 }
|
|
|
|
eoPowerStateChange NOTIFICATION-TYPE
|
|
OBJECTS {eoPowerAdminState, eoPowerOperState,
|
|
eoPowerStateEnterReason}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The SNMP entity generates the eoPowerStateChange when
|
|
the values of eoPowerAdminState or eoPowerOperState,
|
|
in the context of the Power State Set, have changed for
|
|
the Energy Object represented by the entPhysicalIndex."
|
|
::= { energyObjectMibNotifs 2 }
|
|
|
|
-- Conformance
|
|
|
|
energyObjectMibCompliances OBJECT IDENTIFIER
|
|
::= { energyObjectMibConform 1 }
|
|
|
|
energyObjectMibGroups OBJECT IDENTIFIER
|
|
::= { energyObjectMibConform 2 }
|
|
energyObjectMibFullCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this MIB is implemented with support for
|
|
read-create, then such an implementation can
|
|
claim full compliance. Such devices can then
|
|
be both monitored and configured with this MIB.
|
|
|
|
Module Compliance of RFC 6933
|
|
with respect to entity4CRCompliance MUST
|
|
be supported, which requires implementation
|
|
of four MIB objects: entPhysicalIndex, entPhysicalClass,
|
|
entPhysicalName and entPhysicalUUID."
|
|
REFERENCE
|
|
"RFC 6933: Entity MIB (Version 4)"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
energyObjectMibTableGroup,
|
|
energyObjectMibStateTableGroup,
|
|
eoPowerEnableStatusNotificationGroup,
|
|
energyObjectMibNotifGroup
|
|
}
|
|
|
|
GROUP energyObjectMibEnergyTableGroup
|
|
DESCRIPTION
|
|
"A compliant implementation does not
|
|
have to implement."
|
|
|
|
GROUP energyObjectMibEnergyParametersTableGroup
|
|
DESCRIPTION
|
|
"A compliant implementation does not
|
|
have to implement."
|
|
|
|
GROUP energyObjectMibMeterCapabilitiesTableGroup
|
|
DESCRIPTION
|
|
"A compliant implementation does not
|
|
have to implement."
|
|
::= { energyObjectMibCompliances 1 }
|
|
|
|
energyObjectMibReadOnlyCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this MIB is implemented without support for
|
|
read-create (i.e., in read-only mode), then such an
|
|
implementation can claim read-only compliance. Such a
|
|
device can then be monitored but cannot be
|
|
configured with this MIB.
|
|
|
|
Module Compliance of [RFC6933] with respect to
|
|
entity4CRCompliance MUST be supported which requires
|
|
implementation of 4 MIB objects: entPhysicalIndex,
|
|
entPhysicalClass, entPhysicalName and entPhysicalUUID."
|
|
REFERENCE
|
|
"RFC 6933: Entity MIB (Version 4)"
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
energyObjectMibTableGroup,
|
|
energyObjectMibStateTableGroup,
|
|
energyObjectMibNotifGroup
|
|
}
|
|
::= { energyObjectMibCompliances 2 }
|
|
|
|
-- Units of Conformance
|
|
|
|
energyObjectMibTableGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eoPower,
|
|
eoPowerNameplate,
|
|
eoPowerUnitMultiplier,
|
|
eoPowerAccuracy,
|
|
eoPowerMeasurementCaliber,
|
|
eoPowerCurrentType,
|
|
eoPowerMeasurementLocal,
|
|
eoPowerAdminState,
|
|
eoPowerOperState,
|
|
eoPowerStateEnterReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the collection of all the objects
|
|
related to the Energy Object."
|
|
::= { energyObjectMibGroups 1 }
|
|
|
|
energyObjectMibStateTableGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eoPowerStateMaxPower,
|
|
eoPowerStatePowerUnitMultiplier,
|
|
eoPowerStateTotalTime,
|
|
eoPowerStateEnterCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the collection of all the objects
|
|
related to the Power State."
|
|
::= { energyObjectMibGroups 2 }
|
|
|
|
energyObjectMibEnergyParametersTableGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eoEnergyParametersIntervalLength,
|
|
eoEnergyParametersIntervalNumber,
|
|
eoEnergyParametersIntervalMode,
|
|
eoEnergyParametersIntervalWindow,
|
|
eoEnergyParametersSampleRate,
|
|
eoEnergyParametersStorageType,
|
|
eoEnergyParametersStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the collection of all the objects
|
|
related to the configuration of the Energy Table."
|
|
::= { energyObjectMibGroups 3 }
|
|
|
|
energyObjectMibEnergyTableGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
-- Note that object
|
|
-- eoEnergyCollectionStartTime is not
|
|
-- included since it is not-accessible
|
|
|
|
eoEnergyConsumed,
|
|
eoEnergyProvided,
|
|
eoEnergyStored,
|
|
eoEnergyUnitMultiplier,
|
|
eoEnergyAccuracy,
|
|
eoEnergyMaxConsumed,
|
|
eoEnergyMaxProduced,
|
|
eoEnergyDiscontinuityTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the collection of all the objects
|
|
related to the Energy Table."
|
|
::= { energyObjectMibGroups 4 }
|
|
|
|
energyObjectMibMeterCapabilitiesTableGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
eoMeterCapability
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the object indicating the capability
|
|
of the Energy Object"
|
|
::= { energyObjectMibGroups 5 }
|
|
|
|
eoPowerEnableStatusNotificationGroup OBJECT-GROUP
|
|
OBJECTS { eoPowerEnableStatusNotification }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The collection of objects that are used to enable
|
|
notification."
|
|
::= { energyObjectMibGroups 6 }
|
|
|
|
energyObjectMibNotifGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
eoPowerStateChange
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group contains the notifications for
|
|
the Monitoring and Control MIB for Power and Energy."
|
|
::= { energyObjectMibGroups 7 }
|
|
|
|
END
|