-- RAISECOM-ERPS-MIB.MIB: Raisecom ERPS MIB file
--
-- Jul. 2009, guoxiaodan
--
-- Copyright (c) 1994-2010, 2010 by Raisecom, Inc.
-- All rights reserved.
-- Modify Record
-- 20120203,huxiangfeng,ROS00009982, rcErpsLastStatusOccur读写权限不正确
-- 20120116,huochao,ROS00009650 V5R0 ERPS WTB定时器不再支持配置
-- 20111022, yangzhonghong,修改节点rcErpsFdLink的取值为12
-- 20111018yangkewei,ROS00005290修改rcErpsLinkDirection取值为{1,2}
-- 20110803, guoxiaodan, mib校验修改
-- *****************************************************************
RAISECOM-ERPS-MIB DEFINITIONS ::= BEGIN
IMPORTS
iscomSwitch
FROM RAISECOM-BASE-MIB
MODULE-IDENTITY, OBJECT-TYPE, Integer32,
Unsigned32, Gauge32, NOTIFICATION-TYPE
FROM SNMPv2-SMI -- RFC2578
TEXTUAL-CONVENTION, RowStatus,
MacAddress, TruthValue
FROM SNMPv2-TC -- RFC2579
EnableVar,Vlanset
FROM SWITCH-TC;
rcErps MODULE-IDENTITY
LAST-UPDATED "1010210000Z"
ORGANIZATION "Raisecom China World"
CONTACT-INFO
"
Phone: 01082884499
Email: support@raisecom.com"
DESCRIPTION
"The MIB module for Ethernet Ring protocol."
REVISION "0907270000Z"
DESCRIPTION
"Ethernet Ring Protection Switch MIB."
::= {iscomSwitch 53}
rcErpsBaseGroup OBJECT IDENTIFIER ::= { rcErps 1 }
rcErpsFailureDetGroup OBJECT IDENTIFIER ::= { rcErps 2 }
rcErpsTrapGroup OBJECT IDENTIFIER ::= { rcErps 3 }
-- rcErpsBaseGroup
-- ---------------------------------------------------------------- --
rcErpsTrapEnable OBJECT-TYPE
SYNTAX EnableVar
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates whether traps for G.8032
should be generated or not."
DEFVAL { disable }
::= { rcErpsBaseGroup 1 }
rcErpsCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcErpsCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of erps configuration and associated properties."
::= { rcErpsBaseGroup 2}
rcErpsCfgEntry OBJECT-TYPE
SYNTAX RcErpsCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table entry for erps configuration and associated properties."
INDEX { rcErpsId }
::= { rcErpsCfgTable 1 }
RcErpsCfgEntry ::= SEQUENCE {
rcErpsId Unsigned32,
rcErpsName OCTET STRING(SIZE (1..32)),
rcErpsEastPort Integer32,
rcErpsWestPort Integer32,
rcErpsNodeType Integer32,
rcErpsRplLink Integer32,
rcErpsRevertMode Integer32,
rcErpsBlockVlanList Vlanset,
rcErpsForceSwitch Integer32,
rcErpsManualSwitch Integer32,
rcErpsGuardTime Unsigned32,
rcErpsWtrTime Unsigned32,
rcErpsWtbTime Unsigned32,
rcErpsHoldOffTime Unsigned32,
rcErpsProtocolPropagate Integer32,
rcErpsClearAdminCmd TruthValue,
rcErpsProtocolVlan Integer32,
rcErpsProtocolVersion Integer32,
rcErpsRapsVC Integer32,
rcErpsRowStatus RowStatus
}
rcErpsId OBJECT-TYPE
SYNTAX Unsigned32(1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index uniquely identifies a Ring, which ranges from 1~255. This value can't be modified after created."
::= { rcErpsCfgEntry 1 }
rcErpsName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Name for the associtaed Ring protection."
::= { rcErpsCfgEntry 2 }
rcErpsEastPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The east port of the ring node."
::= { rcErpsCfgEntry 3 }
rcErpsWestPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The west port of the ring node."
::= { rcErpsCfgEntry 4 }
rcErpsNodeType OBJECT-TYPE
SYNTAX Integer32{
transfer(0),
owner(1),
neighbour(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of the ring node."
DEFVAL { 0 }
::= { rcErpsCfgEntry 5 }
rcErpsRplLink OBJECT-TYPE
SYNTAX Integer32{
east(0),
west(1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The position of RPL, when rcErpsNodeType=owner(1) it make sense."
::= { rcErpsCfgEntry 6 }
rcErpsRevertMode OBJECT-TYPE
SYNTAX Integer32{
revertive(1),
non-revertive(0)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The mode of revertive node."
DEFVAL{1}
::= { rcErpsCfgEntry 7 }
rcErpsBlockVlanList OBJECT-TYPE
SYNTAX Vlanset
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Traffic Vlanlist of the specific ring."
::= { rcErpsCfgEntry 9 }
rcErpsForceSwitch OBJECT-TYPE
SYNTAX Integer32{
east(0),
west(1),
none(2),
both(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This command forces a block on the ring port where the command is issued."
DEFVAL{2}
::= { rcErpsCfgEntry 10 }
rcErpsManualSwitch OBJECT-TYPE
SYNTAX Integer32{
east(0),
west(1),
none(2)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In the absence of a failure or FS, this command forces a block on the ring
port where the command is issued."
DEFVAL{2}
::= { rcErpsCfgEntry 11 }
rcErpsGuardTime OBJECT-TYPE
SYNTAX Unsigned32 (20..2000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The guard timer is used to prevent Ethernet ring nodes from acting upon
outdated R-APS messages and prevents the possibility of forming a closed loop.
The period of the guard timer may be configured by the operator in 10 ms steps
between 10 ms and 2 seconds, with a default value of 500 ms."
DEFVAL { 500 }
::= { rcErpsCfgEntry 12 }
rcErpsWtrTime OBJECT-TYPE
SYNTAX Unsigned32 (1..12)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In revertive mode of operation, to prevent frequent operation of the protection switch
due to an intermittent defect, a failed working transport entity must become fault-free.
After the failed working transport entity meets this criterion, a fixed period of time
shall elapse before a normal traffic signal uses it again. This period, called
wait-to-restore (WTR) period, may be configured by the operator in 1 minute steps
between 5 and 12 minutes; the default value is 5 minutes."
DEFVAL { 5 }
::= { rcErpsCfgEntry 13 }
rcErpsWtbTime OBJECT-TYPE
SYNTAX Unsigned32 (1..12)
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"The Wtb timer, called wait-to-block timer, may be configured by the operator in 1 second steps
between 1 and 12 seconds;"
DEFVAL { 5 }
::= { rcErpsCfgEntry 14 }
rcErpsHoldOffTime OBJECT-TYPE
SYNTAX Unsigned32(0..100)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When a new defect or more severe defect occurs (new SF), this event will not be
reported immediately to protection switching if the provisioned holdoff timer
value is non-zero. Instead, the holdoff timer will be started. When the holdoff
timer expires, whether a defect still exists on the trail that started the timer
will be checked. If one does exist, that defect will be reported to protection
switching. Each protection group should have a provisionable holdoff timer. The
suggested range of the holdoff timer is 0 to 10 seconds in steps of 100 ms with
an accuracy of 5 ms."
DEFVAL { 0 }
::= { rcErpsCfgEntry 15 }
rcErpsProtocolPropagate OBJECT-TYPE
SYNTAX Integer32 {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The interconnection flush logic is used for interconnection node. It receives topology change notifications
from other connected entities, e.g. a sub-ring ERP control process, and if MI_Propagate_TC is enabled
it flushes the FDB for the local ring links and triggers transmission of R-APS event requests to both ring ports."
DEFVAL{2}
::= { rcErpsCfgEntry 16 }
rcErpsClearAdminCmd OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the FS/MS command."
DEFVAL{2}
::= { rcErpsCfgEntry 17 }
rcErpsProtocolVlan OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Vlan of APS packet."
::= { rcErpsCfgEntry 18 }
rcErpsProtocolVersion OBJECT-TYPE
SYNTAX Integer32{
v1(1),
v2(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The version of the protocol."
DEFVAL{ 1 }
::= { rcErpsCfgEntry 19 }
rcErpsRapsVC OBJECT-TYPE
SYNTAX Integer32 {
with(1),
with-out(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The way to implement a sub-ring"
DEFVAL{ 1 }
::= { rcErpsCfgEntry 20 }
rcErpsRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "This object is responsible for managing the creation, deletion and modification of rows,
which support active status and CreatAndGo, destroy operation.
This object is responsible for managing the creation, deletion and modification of rows,
which support active status and CreatAndGo, destroy operation."
DEFVAL{false}
::= { rcErpsCfgEntry 21 }
-- cErpsStatusTable
rcErpsStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcErpsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of erps status information."
::= { rcErpsBaseGroup 3}
rcErpsStatusEntry OBJECT-TYPE
SYNTAX RcErpsStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of erps status information."
INDEX { rcErpsId }
::= { rcErpsStatusTable 1 }
RcErpsStatusEntry ::= SEQUENCE {
rcErpsStatus Unsigned32,
rcErpsLastStatusOccur TimeTicks,
rcErpsSwitchCounts Unsigned32,
rcErpsClearStatistics TruthValue
}
rcErpsStatus OBJECT-TYPE
SYNTAX Unsigned32 {
idle(1),
protection(2),
ms(3),
fs(4),
pending(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Ethernet bridge status.The default state is pending;"
::= { rcErpsStatusEntry 1}
rcErpsLastStatusOccur OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time when last switch happens."
::= { rcErpsStatusEntry 2 }
rcErpsSwitchCounts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The times of bridge state switching."
::= { rcErpsStatusEntry 3 }
rcErpsClearStatistics OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the statistics or not."
DEFVAL{2}
::= { rcErpsStatusEntry 4 }
-- rcErpsLinkStatusTable
rcErpsLinkStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcErpsLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of erps link status information."
::= { rcErpsBaseGroup 4}
rcErpsLinkStatusEntry OBJECT-TYPE
SYNTAX RcErpsLinkStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of erps link status information."
INDEX { rcErpsId, rcErpsLinkDirection }
::= { rcErpsLinkStatusTable 1 }
RcErpsLinkStatusEntry ::= SEQUENCE {
rcErpsLinkDirection Integer32,
rcErpsLinkTrafficStatus Integer32,
rcErpsLinkLastStatusOccur TimeTicks,
rcErpsLinkSwitchCounts Unsigned32,
rcErpsLinkRapsTx Unsigned32,
rcErpsLinkRapsRx Unsigned32,
rcErpsLinkFlushCounts Unsigned32
}
rcErpsLinkDirection OBJECT-TYPE
SYNTAX Integer32 {
east(1),
west(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The direction of the Erps link."
::= { rcErpsLinkStatusEntry 1 }
rcErpsLinkTrafficStatus OBJECT-TYPE
SYNTAX Integer32 {
block(1),
forwarding(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of ethernet ring port, including block and forward."
::= { rcErpsLinkStatusEntry 2 }
rcErpsLinkLastStatusOccur OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time of last traffic status changed."
::= { rcErpsLinkStatusEntry 3 }
rcErpsLinkSwitchCounts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Switch count of link state between block and forward state."
::= { rcErpsLinkStatusEntry 4 }
rcErpsLinkRapsTx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packet number which sent to the ring link."
::= { rcErpsLinkStatusEntry 5 }
rcErpsLinkRapsRx OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Packet number which received from the ring link."
::= { rcErpsLinkStatusEntry 6 }
rcErpsLinkFlushCounts OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The times of mac flushing"
::= { rcErpsLinkStatusEntry 7 }
-- rcErpsFailureDetGroup
-- rcErpsFailureDetTable
rcErpsFailureDetTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcErpsFailureDetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of erps failure information."
::= { rcErpsFailureDetGroup 1}
rcErpsFailureDetEntry OBJECT-TYPE
SYNTAX RcErpsFailureDetEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of erps failure detecting."
INDEX { rcErpsId, rcErpsFdLink }
::= { rcErpsFailureDetTable 1 }
RcErpsFailureDetEntry ::= SEQUENCE {
rcErpsFdLink INTEGER,
rcErpsFdType INTEGER,
rcErpsFdLinkStatus INTEGER,
rcErpsFdSfType INTEGER,
rcErpsFdMdName OCTET STRING,
rcErpsFdMaName OCTET STRING,
rcErpsFdLocalMep INTEGER,
rcErpsFdRemoteMep INTEGER,
rcErpsFdMdLevel INTEGER
}
rcErpsFdLink OBJECT-TYPE
SYNTAX INTEGER{
east(1),
west(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The link of failure detecting."
::= { rcErpsFailureDetEntry 1 }
rcErpsFdType OBJECT-TYPE
SYNTAX INTEGER{
physical-link(1),
cc(2),
both(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The failure detection type for the link."
DEFVAL{ 1 }
::= { rcErpsFailureDetEntry 2 }
rcErpsFdLinkStatus OBJECT-TYPE
SYNTAX INTEGER{
ok(1),
sf(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The link status."
::= { rcErpsFailureDetEntry 3 }
rcErpsFdSfType OBJECT-TYPE
SYNTAX INTEGER{
none(0),
physical-link(1),
cc(2),
both(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The failure detect types which have triggered SF."
::= { rcErpsFailureDetEntry 4 }
rcErpsFdMdName OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maintenance Domain name. Each Maintenance Domain has unique name amongst all
those used or available to a service provider or operator. It facilitates easy
identification of administrative responsibility for each Maintenance Domain."
::= { rcErpsFailureDetEntry 5 }
rcErpsFdMaName OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(1..13))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Short Maintenance Association name. The type/format of this object is determined
by the value of the dot1agCfmMaNetNameType object. This name must be unique
within a maintenance domain."
::= { rcErpsFailureDetEntry 6 }
rcErpsFdLocalMep OBJECT-TYPE
SYNTAX INTEGER(1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Local MEPId of working or protection entity, identifying a specific MEP."
::= { rcErpsFailureDetEntry 7 }
rcErpsFdRemoteMep OBJECT-TYPE
SYNTAX INTEGER(1..8191)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Remote MEPId of working or protection entity, identifying a specific MEP."
::= { rcErpsFailureDetEntry 8 }
rcErpsFdMdLevel OBJECT-TYPE
SYNTAX INTEGER(0..7)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The level of traffic."
DEFVAL{0}
::= { rcErpsFailureDetEntry 9 }
-- rcErpsTrapGroup
-- Notification Definition section
rcErpsLinkTrafficChangeTrap NOTIFICATION-TYPE
OBJECTS {
rcErpsLinkTrafficStatus
}
STATUS current
DESCRIPTION
"Generated when port state changes between block and forward status."
::= { rcErpsTrapGroup 1 }
rcErpsStatusChangeTrap NOTIFICATION-TYPE
OBJECTS {
rcErpsStatus
}
STATUS current
DESCRIPTION
"Generated when bridge state changes between idle and protection state."
::= { rcErpsTrapGroup 2 }
rcErpsFopMismatch NOTIFICATION-TYPE
OBJECTS {
rcErpsId
}
STATUS current
DESCRIPTION
"Generated when the configuration is wrong on the ring."
::= { rcErpsTrapGroup 3 }
END