8748 lines
259 KiB
Plaintext
8748 lines
259 KiB
Plaintext
RAD-Dacs-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- Title: Dacs MIB
|
|
-- *** This file is for the modified newmasking MIB. ***
|
|
-- Copyright 2000 RAD Data Communications, Ltd.
|
|
-- All Rights Reserved.
|
|
|
|
-- It is RAD's intent to encourage the widespread use of
|
|
-- this Specification in connection with the management of
|
|
-- RAD products. RAD grants vendors, end-users,
|
|
-- and other interested parties a non-exclusive license to
|
|
-- use this Specification in connection with the management
|
|
-- of RAD products.
|
|
|
|
-- This Specification is supplied "as is," and RAD makes
|
|
-- no warranty, either express or implied, as to the use,
|
|
-- operation, condition, or performance of the Specification.
|
|
|
|
|
|
IMPORTS
|
|
|
|
entPhysicalEntry, PhysicalIndexOrZero, entPhysicalSoftwareRev,
|
|
entPhysicalAlias, entPhysicalHardwareRev, entPhysicalDescr FROM ENTITY-MIB
|
|
InetAddressType, InetAddress FROM INET-ADDRESS-MIB
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
sysName FROM SNMPv2-MIB
|
|
Integer32, TimeTicks, Gauge32,
|
|
Unsigned32, OBJECT-TYPE, MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE, OBJECT-IDENTITY FROM SNMPv2-SMI
|
|
DisplayString, RowStatus, MacAddress,
|
|
TruthValue FROM SNMPv2-TC
|
|
radWan FROM RAD-SMI-MIB
|
|
alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, systemsEvents,
|
|
agnLed, alarmEventReason, agnThresholdMin,
|
|
agnThresholdMax, agnThresholdUom FROM RAD-GEN-MIB
|
|
protectGroupLastSwitchReason, protectGroupLastCmd FROM RAD-Protection-MIB
|
|
SlotType, CardType, ProtectGroupCmdType,
|
|
ProtectLastSwitchReasonType FROM RAD-TC;
|
|
|
|
|
|
dacsMux MODULE-IDENTITY
|
|
LAST-UPDATED "201604211736Z" -- April 21, 2016
|
|
ORGANIZATION "RAD Data Communications Ltd."
|
|
CONTACT-INFO
|
|
"System Department
|
|
|
|
Email: mibs@rad.com
|
|
Postal: RAD Data Communications Ltd.
|
|
24 Raoul Wallenberg St.
|
|
Tel-Aviv 6971920
|
|
Israel
|
|
|
|
Phone: +972-3-645-5421
|
|
Fax: +972-3-760-7844"
|
|
DESCRIPTION
|
|
"Digital Access and Cross Connect System device MIB."
|
|
::= { radWan 3 }
|
|
|
|
|
|
systemDacsMux OBJECT IDENTIFIER ::= {dacsMux 1}
|
|
mdlDacsMux OBJECT IDENTIFIER ::= {dacsMux 2}
|
|
prtDacsMux OBJECT IDENTIFIER ::= {dacsMux 3}
|
|
genDacsMux OBJECT IDENTIFIER ::= {dacsMux 4}
|
|
|
|
|
|
--System level of DACS MIB
|
|
--
|
|
--Sa - data specific to a stand-alone unit
|
|
--Hub - data specific to a Hub unit
|
|
--Rest of the branches are common to both types of units.
|
|
|
|
sysSa OBJECT IDENTIFIER ::= {systemDacsMux 1}
|
|
sysHub OBJECT IDENTIFIER ::= {systemDacsMux 2}
|
|
sysStatus OBJECT IDENTIFIER ::= {systemDacsMux 3}
|
|
sysCurrentAlr OBJECT IDENTIFIER ::= {systemDacsMux 4}
|
|
sysBufferAlr OBJECT IDENTIFIER ::= {systemDacsMux 5}
|
|
sysConfig OBJECT IDENTIFIER ::= {systemDacsMux 6}
|
|
sysDbase OBJECT IDENTIFIER ::= {systemDacsMux 7}
|
|
|
|
|
|
--Stand-alone specific parameters
|
|
|
|
sysSaSwchStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of the switches on
|
|
the SA unit.
|
|
Each switch is represented by a bit. The status is a sum
|
|
of 2**n, according to the bits.
|
|
|
|
For SMODs products see modem's specification.
|
|
|
|
For DXC product see the following:
|
|
There are 4 switches:
|
|
bit 0 SP-PAR (LSB) '1' - Default parameters
|
|
bit 1 PSWRD '1' - Password=default
|
|
'0' - Password=user selected
|
|
bit 2 DB-INIT '1' - DB initiated with default
|
|
'0' - DB initiated with NVRAM contents
|
|
bit 3 PC-SP (MSB) '1' - Management by terminal only
|
|
'0' - Management by NMS
|
|
Example: If SP-PAR and PSWRD bits are set ('1'), the value
|
|
will be 3 (2**1 + 2**0).
|
|
When the status of the switches is unknown, the value of
|
|
this object will be 255."
|
|
::= { sysSa 1}
|
|
|
|
sysSaSwRevision OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Software revision of the
|
|
system."
|
|
::= {sysSa 2}
|
|
|
|
sysSaHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Hardware version of the
|
|
system."
|
|
::= {sysSa 3}
|
|
|
|
sysSaPorts OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the ports that are present in the
|
|
system.
|
|
Each possible port is represented by a bit.
|
|
The value of this object is a sum of 2**n, n=number of bits.
|
|
'1' - means that the port exists
|
|
'0' - means that the port does not exist
|
|
For detailed bit assignment, see product's spec.
|
|
Bit 0 = LSB
|
|
When this object is not relevant, the value will be 0.
|
|
In some cases, this object may represent ports configuration
|
|
of the system AND its far-end unit."
|
|
::= {sysSa 4}
|
|
|
|
sysSaReadSwch OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates wether the configuration will be read from the DIP switches
|
|
on the SA (stand alone) unit.
|
|
Each switch is represented by a bit.
|
|
If the bit is 1: the configuration will be read from the HW switch position.
|
|
If the bit is 0: the configuration will be read from the SW user configuration.
|
|
|
|
The DIP switches are different in each of the RAD devices.
|
|
In the Tiny Router (starting from the LSB) the following switches exist:
|
|
Bit 0: WAN Loop
|
|
Bit 1: LAN Full Duplex (When LAN AUI connector, it is SQE)
|
|
Bit 2: PPP (When WAN 4 Wire connector, it is LONG)
|
|
Bit 3: IP Learn"
|
|
::= {sysSa 5}
|
|
|
|
sysSaBuActivePort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
e1T1orSerial (2),
|
|
eth (3),
|
|
primary (4),
|
|
secondary (5),
|
|
third (6),
|
|
fourth (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object shows through which port the traffic is flowing
|
|
(the current Active Port) when the Backup mechanism exists.
|
|
When No Backup exists in the device, the value should be: notApplicable(1)."
|
|
::= {sysSa 6}
|
|
|
|
|
|
--Hub specific parameters
|
|
|
|
--Hub Cassis data
|
|
|
|
sysChas OBJECT IDENTIFIER ::= {sysHub 1}
|
|
|
|
chassTotalNoOfSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of physical slots in
|
|
the Hub chassis."
|
|
::= { sysChas 1 }
|
|
|
|
chassTotalNoOfIoSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the total number of physical IO slots
|
|
in the chassis, (not all slots must be occupied and active)."
|
|
::= { sysChas 2 }
|
|
|
|
chassTotalNoOfPsSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of physical Power Supply
|
|
slots in the chassis."
|
|
::= { sysChas 3 }
|
|
|
|
chassTotalNoOfClSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of physical Common Logic
|
|
slots in the chassis."
|
|
::= { sysChas 4 }
|
|
|
|
chassTotalNoOfMlSlt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of physical Main Link
|
|
slots in the chassis (Kmux)."
|
|
::= { sysChas 5 }
|
|
|
|
|
|
--Hub DCL parameters
|
|
|
|
sysDcl OBJECT IDENTIFIER ::= {sysHub 2}
|
|
|
|
|
|
sysDclTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysDclEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the entries of this table are identical (have the
|
|
same value) for all the configurations (1..255) except
|
|
the TmpCnfg.
|
|
The write operation into the Table Objects is valid only
|
|
for the TmpCnfg entry."
|
|
::= { sysDcl 1}
|
|
|
|
sysDclEntry OBJECT-TYPE
|
|
SYNTAX SysDclEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {sysDclCnfgIdx}
|
|
::= { sysDclTable 1}
|
|
|
|
SysDclEntry ::=
|
|
SEQUENCE {
|
|
sysDclCnfgIdx Integer32,
|
|
sysDclRedundancy INTEGER,
|
|
sysDclActiveCl INTEGER,
|
|
sysDclFlipDelay Integer32,
|
|
sysDclFlipUponStnClk INTEGER,
|
|
sysDclChFailThreshold Integer32,
|
|
sysDclChPriority OCTET STRING,
|
|
sysDclConfigDownloadSrc INTEGER,
|
|
sysDclSwDownloadSrc INTEGER,
|
|
sysDclRedundancyStatus BITS
|
|
}
|
|
|
|
sysDclCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg(1..255)
|
|
being accessed ; Idx of 255 relates to the TmpCnfg.
|
|
This object is identical for all the configurations (1..255).
|
|
Only the TmpCnf(255) might have a different value.
|
|
For devices that work on line with NMS (no Temp configuration in NMS),
|
|
Get and Set will be performed with index value of sysDclCnfgIdx = 1."
|
|
::= { sysDclEntry 1}
|
|
-- In phase I only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
sysDclRedundancy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" DCL redundancy desired state."
|
|
::= {sysDclEntry 2}
|
|
|
|
sysDclActiveCl OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto (1),
|
|
dclA (2),
|
|
dclB (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Active desired DCL.
|
|
When 'auto' is selected, the system automatically selects
|
|
the active DCL."
|
|
::= {sysDclEntry 3}
|
|
|
|
sysDclFlipDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
-- {
|
|
-- t1min (1),
|
|
-- t2min (2),
|
|
-- t3min (3),
|
|
-- t4min (4)
|
|
-- }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If one DCL flip occurred and a second one should be
|
|
performed, the time from the previous flip is checked.
|
|
If the time is shorter than the delay specified here,
|
|
the system should delay the flip operation until time reaches the specified delay.
|
|
For DXC the values are 1 minute to 4 minutes (1..4).
|
|
For Optimux-155-1 and Optimux-155-3 the values are: 0...60 Sec.
|
|
0 means No Delay."
|
|
::= {sysDclEntry 4}
|
|
|
|
sysDclFlipUponStnClk OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows user to decide (yes/no) if Agent should Flip from
|
|
one DCL card to another, when there is Station Clock Fail in
|
|
the Online DCL card."
|
|
::= {sysDclEntry 5}
|
|
|
|
sysDclChFailThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of failed channels that will trigger the
|
|
redundancy procedure."
|
|
::= {sysDclEntry 6}
|
|
|
|
sysDclChPriority OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Priority for all the channels in the Main Access
|
|
(Common Logic) card. Each channel is represented by 1 bit.
|
|
The order of the bits in each byte is from Right to Left (LSB Bit to MSB)
|
|
starting from BIT 0: 7 6 5 4 3 2 1 0
|
|
|
|
Channel no. 1 is represented by bit 0.
|
|
Channel no. 2 is represented by bit 1.
|
|
Channel no. n is represented by bit n-1.
|
|
|
|
The value of the bit shows the priority.
|
|
For bit value = 1, Priority = High.
|
|
For bit value = 0, Priority = Low."
|
|
::= {sysDclEntry 7}
|
|
|
|
sysDclConfigDownloadSrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (1),
|
|
dclA (2),
|
|
dclB (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case of mismatch between the 2 CL card's configuration, the user can decide
|
|
which card has the suitable configuration.
|
|
The selected configuration will be downloaded from card A to card B
|
|
if the value is dclA(2) or from card B to card A if the value is dclB(3).
|
|
off(1) is used by part of the devices. In this case, after operation ends -
|
|
value should be automatically set to off(1), which is the default state."
|
|
::= {sysDclEntry 8}
|
|
|
|
|
|
sysDclSwDownloadSrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (1),
|
|
dclA (2),
|
|
dclB (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"In case of mismatch between the 2 CL card's software, the user can decide
|
|
which card has the suitable SW.
|
|
The selected SW will be downloaded from card A to card B if the value is dclA(2)
|
|
or from card B to card A if the value is dclB(3).
|
|
off(1) is used by part of the devices. In this case, after operation ends -
|
|
value should be automatically set to off(1), which is the default state."
|
|
::= {sysDclEntry 9}
|
|
|
|
sysDclRedundancyStatus OBJECT-TYPE
|
|
SYNTAX BITS
|
|
{
|
|
cnfgMismatch (0),
|
|
swMismatch (1),
|
|
cardAAbsent (2),
|
|
cardBAbsent (3),
|
|
lossOfCommunication (4),
|
|
hwMismatch (5),
|
|
cnfgUpdate (6),
|
|
swUpdate (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Bit map representing current Redundancy Status.
|
|
bit 0 - Indicates mismatch between the 2 CL cards' Configuration
|
|
bit 1 - Indicates mismatch between the 2 CL cards' Software.
|
|
bit 2 - Indicates CL card A Absence.
|
|
bit 3 - Indicates CL card B Absence.
|
|
bit 4 - Indicates Loss of Communication between the 2 CL cards.
|
|
bit 5 - Indicates mismatch between the 2 CL cards' Hardware.
|
|
bit 6 - Indicates Configuraton update is in process.
|
|
bit 7 - Indicates Software update is in process.
|
|
"
|
|
::= {sysDclEntry 10}
|
|
|
|
|
|
sysDclOnline OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dclA (1),
|
|
dclB (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The active Dcl card of the agent."
|
|
::= {sysDcl 2}
|
|
|
|
sysDclCopyDbTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysDclCopyDbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table enables to copy a cofiguration from the Offline
|
|
Dcl to the Online Dcl."
|
|
::= { sysDcl 3}
|
|
|
|
sysDclCopyDbEntry OBJECT-TYPE
|
|
SYNTAX SysDclCopyDbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {sysDclCopyDbIdx}
|
|
::= { sysDclCopyDbTable 1}
|
|
|
|
SysDclCopyDbEntry ::=
|
|
SEQUENCE {
|
|
sysDclCopyDbIdx Integer32,
|
|
sysDclCopyDbCmd INTEGER
|
|
}
|
|
|
|
sysDclCopyDbIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg(1..255)
|
|
being accessed. "
|
|
::= { sysDclCopyDbEntry 1}
|
|
|
|
sysDclCopyDbCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When this command is sent to the agent, on(3), the Database
|
|
specified (Db Idx), will be copied from the Offline Dcl
|
|
to the Online Dcl. Afterwards the value of this object will
|
|
automatically change to off(2). "
|
|
::= { sysDclCopyDbEntry 2}
|
|
|
|
sysDclFlipCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
flip (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When the 'flip(3)' command is received by Agent, it will flip (switch)
|
|
between Offline Dcl and Online Dcl cards. Afterwards the value of
|
|
this object will automatically change to off(2)."
|
|
::= { sysDcl 4}
|
|
|
|
|
|
--General System - General Status parameters
|
|
|
|
sysSDateFormat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
ddMMYYYY (1),
|
|
mmDDYYYY (2),
|
|
yyyyDDMM (3),
|
|
yyyyMMDD (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the date and time format used for the
|
|
sysSDateAndTimeCmd and for the alarm buffer report."
|
|
::= { sysStatus 1 }
|
|
|
|
sysSDateCmd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current date as it is known by the
|
|
agent using its own real-time clock. The format would be as
|
|
specified by the sysSDateFormat.
|
|
This parameter can be set for time synchronization between
|
|
the NMS and the Agent.
|
|
* For KM-2100 V1 and FCD-T1/E1 - the string should contain
|
|
'/' signs between day, month and year. Example: 12/08/1998.
|
|
* For DXC and rest of the products - the string should contain
|
|
'-' signs between day, month and year. Example: 12-08-1998.
|
|
The day value will be in the range: 1..31.
|
|
The month value will be in the range: 1..12.
|
|
The year value will be in the range: 1996..2050 for products
|
|
supporting the '-' format."
|
|
::= { sysStatus 2 }
|
|
|
|
sysSTimeCmd OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the current time as it is known by the
|
|
agent using its own real-time clock.
|
|
This parameter can be set for time synchronization between
|
|
the NMS and the Agent.
|
|
The string should contain ':' signs between hour, minute
|
|
and second. Example: 11:05:58."
|
|
::= { sysStatus 3 }
|
|
|
|
sysSActiveCnfg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object specifies the configuration number,
|
|
that is currently active and running."
|
|
::= { sysStatus 4 }
|
|
-- return 1 (db1) in phase I
|
|
|
|
sysSEditCnfg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the unique configuration number that
|
|
is currently loaded into the tmp working space for
|
|
manipulation and update operations. Value of 255 means no
|
|
config. is under editing process."
|
|
::= { sysStatus 5 }
|
|
-- return 1 (db1) in phase I
|
|
|
|
|
|
sysSEditBy OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
snmp (2),
|
|
terCon1 (3),
|
|
terCon2 (4),
|
|
terInbandCon1 (5),
|
|
terInbandCon2 (6),
|
|
lcd (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates which MMI application is working on
|
|
the edited config.
|
|
The editing phase starts at the first modify operation and
|
|
ends after a load operation."
|
|
::= { sysStatus 6 }
|
|
|
|
sysSClkSrc OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master (1),
|
|
fallback(2),
|
|
internal(3),
|
|
ml (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the source of the system clock."
|
|
::= { sysStatus 7 }
|
|
|
|
sysSAlrStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
major (3),
|
|
minor (4),
|
|
event (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current alarm state only for system level.
|
|
This object will be :
|
|
- critical(7): when there is at least one active (ON) critical
|
|
alarm .
|
|
- major (3): when there is no active critical alarm, but there is
|
|
at least one active (ON) major alarm .
|
|
- minor (4): when there is no active major or critical alarm, but
|
|
there is at least one active minor alarm.
|
|
- warning (6): when there is no active major, critical or minor alarm, but
|
|
there is at least one active warning alarm.
|
|
- event (5): when there is no active alarm of another type, but
|
|
there is at least one active event alarm.
|
|
- off(2): when there is no active (ON) alarm (since last clear operation)."
|
|
::= { sysStatus 8 }
|
|
|
|
sysSAlrStatusAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
major (3),
|
|
minor (4),
|
|
event (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current alarm state including all levels:
|
|
system, card, port.
|
|
- critical(7): when there is at least one active (ON) critical
|
|
alarm .
|
|
- major (3): when there is no active critical alarm, but there is
|
|
at least one active (ON) major alarm .
|
|
- minor (4): when there is no active major or critical alarm, but
|
|
there is at least one active minor alarm.
|
|
- warning (6): when there is no active major, critical or minor alarm, but
|
|
there is at least one active warning alarm.
|
|
- event (5): when there is no active alarm of another type, but
|
|
there is at least one active event alarm.
|
|
- off(2): when there is no active (ON) alarm (since last clear operation)."
|
|
::= { sysStatus 9 }
|
|
|
|
sysSTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current test status (for all levels: system,
|
|
card, port).
|
|
This attribute will be set to:
|
|
- on(3): when there is at least one test in progress on the
|
|
system/card/port
|
|
otherwise the value will be off(2)."
|
|
::= { sysStatus 10 }
|
|
|
|
|
|
sysSSanityCheckStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
fail (2),
|
|
warning (3),
|
|
ok (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Upon completion of the Sanity Check process on the TmpCnfg
|
|
this object will be set to:
|
|
- fail(2): when there is at least one error (which is
|
|
not just a warning) encountered
|
|
otherwise,
|
|
- warning(3): when there are only warnings
|
|
otherwise,
|
|
- ok(4).
|
|
The value should be unknown(1), if the TmpCnfg was changed
|
|
after the last Sanity check."
|
|
::= { sysStatus 11 }
|
|
|
|
sysSNoOfSanityCheckErr OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of errors/warnings
|
|
discovered by the last Sanity Check process."
|
|
::= { sysStatus 12 }
|
|
|
|
sysSErrListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysSErrListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { sysStatus 13 }
|
|
|
|
sysSErrListEntry OBJECT-TYPE
|
|
SYNTAX SysSErrListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { sysSErrType, sysSErrIdx}
|
|
::= { sysSErrListTable 1}
|
|
|
|
SysSErrListEntry ::=
|
|
SEQUENCE {
|
|
sysSErrType INTEGER,
|
|
sysSErrIdx Integer32,
|
|
sysSErrDescription DisplayString
|
|
}
|
|
|
|
sysSErrType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
error (1),
|
|
warning (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The errors are recorded in the agent, in two separate lists,
|
|
according to their type: error or warning."
|
|
::= { sysSErrListEntry 1}
|
|
|
|
sysSErrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index number to identify an entry in the error
|
|
or warning list .
|
|
The maximum value cannot exceed the value of
|
|
'sysSNoOfSanityCheckErr' (actually, the sum of the Errors
|
|
list max. index and the Warning list max. index should
|
|
equal the value of'sysSNoOfSanityCheckErr')."
|
|
::= { sysSErrListEntry 2}
|
|
|
|
sysSErrDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a full text description of the sanity check
|
|
error including error code, IO slot and port numbers related to
|
|
the code ."
|
|
::= { sysSErrListEntry 3}
|
|
|
|
sysSMaxNoOfCnfg OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum number of configurations that can be defined and
|
|
stored in the DACS agent.
|
|
If the DACS agent has a large capacity, the maximum will be
|
|
limited to 254."
|
|
::= { sysStatus 14 }
|
|
-- return 1 (db1) in phase I
|
|
|
|
sysSSelfTestResult OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The test is performed by the active Common Logic card.
|
|
The result will be a sum of 2**n according to the following
|
|
bit convention:
|
|
For DXC:
|
|
bit 0 Database 1 Checksum Error (LSB)
|
|
bit 1 Database 2 Checksum Error
|
|
bit 2 I/O Expander Error
|
|
bit 3 Counter Error
|
|
bit 4 Matrix DPR Error
|
|
bit 5 PS-A 5 Volt Error
|
|
bit 6 PS-A 12 Volt Error
|
|
bit 7 PS-B 5 Volt Error
|
|
bit 8 PS-B 12 Volt Error
|
|
bit 9 EPROM Failure
|
|
|
|
For FCD:
|
|
bit 0 I/O Expander Error (LSB)
|
|
bit 1 Counter Error
|
|
bit 2 EPROM Failure
|
|
bit 3 Illegal Sys Config
|
|
bit 4 SFIFO
|
|
bit 5 EPIC Failure (ISDN)
|
|
bit 6 XL Flash Fail -- for MSDSL interface
|
|
bit 7 XL MITEL Fail -- for MSDSL interface
|
|
bit 8 XL Framer Fail -- for MSDSL interface
|
|
bit 9 XL DSP Fail -- for MSDSL interface
|
|
|
|
For LRS52 - refer to product's spec
|
|
|
|
When a bit is ('1'), the error exists.
|
|
When NO ERROR is encountered, this object's value will be 0."
|
|
::= { sysStatus 15 }
|
|
|
|
sysSRelayState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current state of the alarm relay.
|
|
notApplicable - for agents that do not support this object."
|
|
::= { sysStatus 16 }
|
|
|
|
sysSInvertedAlr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if there is any Inverted alarm at any level of the
|
|
system (sys, card, port).
|
|
notApplicable - for agents that do not support this object."
|
|
::= { sysStatus 17 }
|
|
|
|
--The following table reports all the Flip events due to I/O Redundancy
|
|
--since last Clear command of the table.
|
|
|
|
sysSRdnFlipTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysSRdnFlipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes all the Flip events due to I/O Redundancy since
|
|
last Clear command of this table."
|
|
::= { sysStatus 18 }
|
|
|
|
sysSRdnFlipEntry OBJECT-TYPE
|
|
SYNTAX SysSRdnFlipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { sysSRdnFlipIdx}
|
|
::= { sysSRdnFlipTable 1}
|
|
|
|
SysSRdnFlipEntry ::=
|
|
SEQUENCE {
|
|
sysSRdnFlipIdx Integer32,
|
|
sysSRdnFlipSlot INTEGER,
|
|
sysSRdnFlipPort Integer32,
|
|
sysSRdnFlipCause DisplayString,
|
|
sysSRdnFlipDate DisplayString,
|
|
sysSRdnFlipTime DisplayString
|
|
}
|
|
|
|
sysSRdnFlipIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unique index number to identify an entry in the Redundancy Flip list."
|
|
::= { sysSRdnFlipEntry 1}
|
|
|
|
sysSRdnFlipSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number from which Flip was performed."
|
|
::= { sysSRdnFlipEntry 2}
|
|
|
|
sysSRdnFlipPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number from which Flip was performed.
|
|
For DXC:
|
|
For external ports the convention used will be:
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
For internal ports the convention used will be:
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
|
|
For MP:
|
|
For external ports, the value will be as that of the port in the
|
|
card. Example: external-3 -> 3
|
|
external-4 -> 4
|
|
For internal ports, the value will be 100 + the port in the
|
|
card. Example: internal-1 -> 101
|
|
internal-4 -> 104
|
|
|
|
100=notApplicable (when Redundancy is at card level)."
|
|
::= { sysSRdnFlipEntry 3 }
|
|
|
|
sysSRdnFlipCause OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The last cause that caused the Flip from the Slot (Port)
|
|
of sysSRdnSlot, sysSRdnPort."
|
|
::= { sysSRdnFlipEntry 4}
|
|
|
|
sysSRdnFlipDate OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flip event Date. The format will be the one selected by user for
|
|
sysSDateFormat."
|
|
::= { sysSRdnFlipEntry 5}
|
|
|
|
sysSRdnFlipTime OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Flip event Time. The format will be hh:mm:ss."
|
|
::= { sysSRdnFlipEntry 6}
|
|
|
|
sysSRdnFlipTableClearCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This command, when Set to 'on', clears the Redundancy Flip
|
|
table (sysSRdnFlipTable).
|
|
After clear is performed, the agent will turn the value to 'off'
|
|
automatically."
|
|
::= { sysStatus 19 }
|
|
|
|
sysSRdnFlipCmd OBJECT-TYPE
|
|
SYNTAX OBJECT IDENTIFIER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables the user to send a command to the Agent, to Flip
|
|
from a current Online IO card to its Redundant card.
|
|
The value sent will be an Object Identifier of an entry in the sysCRdnTable.
|
|
This entry defines the Redundant couple of Slots on which the Flip
|
|
is applied.
|
|
Setting this object, will cause the Agent to Flip from current Online
|
|
card to its Redundant card.
|
|
This manual flip command is applicable only for entries having
|
|
Redundancy Mode=Y Cable.
|
|
|
|
For Vmux: This command will cause flipping from Secondary or Third Link to the
|
|
Primary Link. If the active link is the primary link, the agent will flip to the
|
|
secondary link. The value sent will be the Object Identifier of the following
|
|
Table: agnCBuMlTable.
|
|
|
|
Agent will send the value 0 for Get."
|
|
::= { sysStatus 20}
|
|
|
|
sysSBusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysSBusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes data and status about the internal DXC BUS."
|
|
::= { sysStatus 21 }
|
|
|
|
sysSBusEntry OBJECT-TYPE
|
|
SYNTAX SysSBusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { sysSBusPortIdx}
|
|
::= { sysSBusTable 1}
|
|
|
|
SysSBusEntry ::=
|
|
SEQUENCE {
|
|
sysSBusPortIdx Integer32,
|
|
sysSBusStatus INTEGER,
|
|
sysSBusCapturePort Integer32,
|
|
sysSBusUtilization Integer32
|
|
}
|
|
|
|
sysSBusPortIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The DXC BUS port number:
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the Bus port number, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
Example: port2 of IO slot 11 will be: 213."
|
|
::= { sysSBusEntry 1 }
|
|
|
|
sysSBusStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
free (1),
|
|
physical(2),
|
|
virtual (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Status of sysSBusPortIdx.
|
|
free - not used
|
|
physical - captured by the port of the card physically installed
|
|
virtual - captured virtually by another port. Example: DIM port
|
|
(by Destination) or by Transparent T3/E3 port."
|
|
::= { sysSBusEntry 2}
|
|
|
|
sysSBusCapturePort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Port that Captured the sysSBusPortIdx.
|
|
- if sysSBusStatus=free, the value will be 'none'=0
|
|
- else, if sysSBusStatus=fixed, the value will be: sysSBusPortIdx
|
|
- else, the value will be according to the port index that captured
|
|
this Bus Port (according to DXC port index convention):
|
|
- xx1, xx3, xx11, xx13, xx31, xx33, xx2..xx56(even numbers)
|
|
- xx = (IO slot number+10) "
|
|
::= { sysSBusEntry 3}
|
|
|
|
sysSBusUtilization OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Utilization of sysSBusPortIdx resources, in percent [%]."
|
|
::= { sysSBusEntry 4}
|
|
|
|
--IO Redundancy - Commands
|
|
--sysSRdnCmdTable was moved to be after sysCRdnTable, in order to solve
|
|
--an SNMPc limitation regarding forward reference of the indexes.
|
|
|
|
sysSAlrAttrIndication OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of the Alarm Attributes
|
|
for the whole device.
|
|
It is a sum of 2**(Bit-1). A Bit will be '1', when any alarm in the
|
|
device is Filtered/Masked/Inverted (respectively).
|
|
The Bit assignment is:
|
|
Bit 1: Filter (LSB)
|
|
Bit 2: Mask
|
|
Bit 3: Invert (MSB).
|
|
Examples:
|
|
- Alarms are filtered and masked but not inverted: value=3
|
|
- Alarm is Inverted (not filtered or masked): value=4
|
|
- Alarm is masked (not inverted or filtered): value=2 "
|
|
::= { sysStatus 23 }
|
|
|
|
|
|
--System Current Alarm Table
|
|
--
|
|
--This table contains all Events and only the major/minor alarms
|
|
--whose status is ON.
|
|
|
|
sysSAlrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysSAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of system level current existing alarms ."
|
|
::= { sysCurrentAlr 1 }
|
|
|
|
sysSAlrEntry OBJECT-TYPE
|
|
SYNTAX SysSAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { sysSAlrIdx}
|
|
::= { sysSAlrTable 1}
|
|
|
|
SysSAlrEntry ::=
|
|
SEQUENCE {
|
|
sysSAlrIdx Integer32,
|
|
sysSAlrCode Integer32,
|
|
sysSAlrState INTEGER, --Severity
|
|
sysSAlarmMask INTEGER,
|
|
sysSAlarmInvert INTEGER,
|
|
sysSAlarmOnOff INTEGER,
|
|
sysSAlarmCounter Integer32
|
|
}
|
|
|
|
sysSAlrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index number of the current system alarms."
|
|
::= { sysSAlrEntry 1 }
|
|
|
|
sysSAlrCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a code related to a specific
|
|
alarm description. The list of codes and their related
|
|
descriptions will be sent to NMS request (for display purpose)
|
|
by alrGenTable."
|
|
::= { sysSAlrEntry 2 }
|
|
|
|
sysSAlrState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the alarm Severity."
|
|
::= { sysSAlrEntry 3 }
|
|
|
|
sysSAlarmMask OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm Mask is : on/off."
|
|
::= { sysSAlrEntry 4 }
|
|
|
|
sysSAlarmInvert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm Invert is : on/off."
|
|
::= { sysSAlrEntry 5 }
|
|
|
|
sysSAlarmOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm state is : on/off."
|
|
::= { sysSAlrEntry 6 }
|
|
|
|
sysSAlarmCounter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter - how many times the alarm occured (ON) since last
|
|
clear operation or since last Reset."
|
|
::= { sysSAlrEntry 7 }
|
|
|
|
sysSAlrClearCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce a clear
|
|
operation on the system level alarms . Upon completion,
|
|
the value will automatically change to off(2)."
|
|
::= { sysCurrentAlr 2 }
|
|
|
|
|
|
sysSAlrClearAllCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce a clear
|
|
operation on all levels alarms . Upon completion,
|
|
the value will automatically change to off(2)."
|
|
::= { sysCurrentAlr 3 }
|
|
|
|
sysSAlrMaskAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"on(3) - will cause masking of all the system level alarms.
|
|
These alarms will not be sent to NMS and will not
|
|
be taken into account for Alarms Status.
|
|
off(2) - will unmask all system level alarms except those
|
|
masked via the sysSAlrMask. "
|
|
::= { sysCurrentAlr 4 }
|
|
|
|
sysSAlrMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a mask that indicates which system level
|
|
alarms are masked. The masked alarms (their bit is set to
|
|
'1') are neither sent to the manager, nor taken into account
|
|
for alarm status and LEDs.
|
|
Bit no. = Alarm code
|
|
The bits that do not belong to the system level will be 0.
|
|
This object is applicable only when sysSAlrMaskAll=off
|
|
(otherwise all system alarms are masked).
|
|
Example: When Alarms having the codes 6 and 11 are masked,
|
|
the value of this object will be 840 (hex)."
|
|
::= { sysCurrentAlr 5 }
|
|
|
|
sysSAlrDataUpdateCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"on(3) - will cause Update of the Alarms Severity, Attributes and Report
|
|
tables.
|
|
off(2) - Upon completion, the value will automatically change to off(2)."
|
|
::= { sysCurrentAlr 6 }
|
|
|
|
|
|
--System Buffer Alarm Table
|
|
--
|
|
--This table contains all Events and all the major/minor alarms
|
|
--The buffer is cyclic and contains the most recent alarms.
|
|
--Since this table contains also the alarms occurence time,
|
|
--(appearance/disappearance for major/minor alarms), an alarm may
|
|
--appear several times in this table, with alternate state: major,
|
|
--off, major, etc..
|
|
|
|
sysBufferAlrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysBufferAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"List of current existing alarms (of all levels)."
|
|
::= { sysBufferAlr 1 }
|
|
|
|
sysBufferAlrEntry OBJECT-TYPE
|
|
SYNTAX SysBufferAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { sysBufferAlrIdx}
|
|
::= { sysBufferAlrTable 1}
|
|
|
|
SysBufferAlrEntry ::=
|
|
SEQUENCE {
|
|
sysBufferAlrIdx Integer32,
|
|
sysBufferAlrCode Integer32,
|
|
sysBufferAlrState INTEGER,
|
|
sysBufferAlrSlot INTEGER,
|
|
sysBufferAlrPort Integer32,
|
|
sysBufferAlrDate DisplayString,
|
|
sysBufferAlrTime DisplayString,
|
|
sysBufferAlrUpTime TimeTicks,
|
|
sysBufferAlrInfo SnmpAdminString
|
|
}
|
|
|
|
sysBufferAlrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index number of the current alarms."
|
|
::= { sysBufferAlrEntry 1 }
|
|
|
|
sysBufferAlrCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a code related to a specific
|
|
alarm description. The list of codes and thir related
|
|
descriptions will be known by the NMS (for display purpose)
|
|
and will appear in the unit's user manual."
|
|
::= { sysBufferAlrEntry 2 }
|
|
|
|
sysBufferAlrState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the alarm type.
|
|
minor/major/warning/critical - indicates appearance of the problem
|
|
and the type.
|
|
event - indicates occurence of an event.
|
|
off - indicates disappearance of an alarm. "
|
|
::= { sysBufferAlrEntry 3 }
|
|
|
|
|
|
sysBufferAlrSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
local (20),
|
|
psC (21),
|
|
kmxPsA (101),
|
|
kmxPsB (102),
|
|
kmxMlA (103),
|
|
kmxMlB (104),
|
|
kmxCl (105),
|
|
kmxOpt (106),
|
|
kmxIO1 (107),
|
|
kmxIO2 (108),
|
|
kmxIO3 (109),
|
|
kmxIO4 (110),
|
|
kmxIO5 (111),
|
|
kmxIO6 (112),
|
|
kmxIO7 (113),
|
|
kmxIO8 (114),
|
|
kmxIO9 (115),
|
|
kmxIO10(116),
|
|
kmxIO11(117),
|
|
kmxIO12(118),
|
|
remote (120),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number this alarm refers to.
|
|
When the alarm refers to a system function OR the DACS agent
|
|
is a stand-alone unit, the value will be 'notApplicable(255)'.
|
|
local/remote - for OP-4 device."
|
|
::= { sysBufferAlrEntry 4 }
|
|
|
|
sysBufferAlrPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number this alarm refers to.
|
|
If the port number is irrelevant to this alarm (if it is
|
|
a system/card level alarm) the value will be 9999."
|
|
::= { sysBufferAlrEntry 5 }
|
|
|
|
sysBufferAlrDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The date when the alarm occured. The format will be according
|
|
to sysSDateFormat."
|
|
::= { sysBufferAlrEntry 6 }
|
|
|
|
|
|
sysBufferAlrTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the alarm occured."
|
|
::= { sysBufferAlrEntry 7 }
|
|
|
|
sysBufferAlrUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time when the alarm occured.
|
|
This parameter holds the sysUpTime value when the alarm occured."
|
|
::= { sysBufferAlrEntry 8 }
|
|
|
|
sysBufferAlrInfo OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter includes information about the alarm (additional to the Description)."
|
|
::= { sysBufferAlrEntry 9}
|
|
|
|
|
|
sysBufferAlrClearCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce a clear
|
|
operation on the Alarms Buffer. Upon completion,
|
|
the value will automatically change to off(2)."
|
|
::= { sysBufferAlr 2 }
|
|
|
|
|
|
--System Configuration Parameters
|
|
|
|
sysCClkSrcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysCClkSrcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the entries of this table are identical (have the
|
|
same value) for all the configurations (1..255) except
|
|
the TmpCnfg.
|
|
For devices with more than one configuration:
|
|
The write operation into the Table Objects is valid only
|
|
for the TmpCnfg entry."
|
|
::= { sysConfig 1}
|
|
|
|
sysCClkSrcEntry OBJECT-TYPE
|
|
SYNTAX SysCClkSrcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {sysCClkCnfgIdx, sysCClkSrcIdx}
|
|
::= { sysCClkSrcTable 1}
|
|
|
|
SysCClkSrcEntry ::= SEQUENCE {
|
|
sysCClkCnfgIdx Integer32,
|
|
sysCClkSrcIdx INTEGER,
|
|
sysCClkSrcMode INTEGER,
|
|
sysCClkSrcPrt Integer32,
|
|
sysCClkStationFreq INTEGER,
|
|
sysCClkRevertiveTimeout Integer32,
|
|
sysCClkStationIf INTEGER,
|
|
sysCClkStationCableMode INTEGER,
|
|
sysCClkStationOutState INTEGER,
|
|
sysCClkSsmBased INTEGER,
|
|
sysCClkSSubsystemSlot INTEGER,
|
|
sysCClkRecoveredID Unsigned32
|
|
}
|
|
|
|
sysCClkCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..2147483647)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg being
|
|
accessed ; Idx of 255 relates to the TmpCnfg.
|
|
It can be also a combination of the configuration number and the
|
|
Card/Port/Other System index."
|
|
::= { sysCClkSrcEntry 1}
|
|
|
|
sysCClkSrcIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
master (1),
|
|
fallback (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index in the table. There are only two entries in the
|
|
table.
|
|
master - refers Master clock parameters
|
|
fallback - refers Fallback clock parameters"
|
|
::= { sysCClkSrcEntry 2}
|
|
|
|
sysCClkSrcMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
internal (2),
|
|
rxClk (3),
|
|
station (4), -- station A (for IPmux1000)
|
|
lbt (5),
|
|
ntr (6),
|
|
adaptive (7),
|
|
stationB (8),
|
|
automatic (9),
|
|
system (10),
|
|
sSubSystem (11),
|
|
recovered (12),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the source the nodal timing is
|
|
locked to.
|
|
none - is an invalid option for Master clock.
|
|
internal - is an invalid option for Fallback clock .
|
|
station - is an invalid option for a stand-alone unit.
|
|
lbt - loop-back timing
|
|
ntr - Network Time Reference
|
|
adaptive - clock locking is achieved by altering the clock
|
|
according to the data load
|
|
system - irrelevant when sysCClkCnfgIdx refers to System Clock.
|
|
sSubSystem - SONET/SDH Sub System.
|
|
recovered - clock recovery.
|
|
notApplicable - for ML source of Kmux or ML Timing
|
|
combinations when Master/Fallback clock are
|
|
not applicable."
|
|
::= { sysCClkSrcEntry 3}
|
|
|
|
|
|
sysCClkSrcPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is valid only when working in rxClk mode
|
|
(for IPmux1000 this entry will be valid whe working in LBT mode).
|
|
|
|
For ACE2002 in case of invalid entry the return value
|
|
will be 0.
|
|
For other products in case of invalid entry the return
|
|
value will be 9999.
|
|
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside,
|
|
SP.
|
|
* The SP ports will be numbered as follows:
|
|
- SP port 1 : 1
|
|
- SP port 2 : 2
|
|
For external ports the convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
For internal ports the convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
|
|
For Kmux, the port will be according to : Slot*100+Ch.
|
|
|
|
For ACE2002, LA140 and IPmux1000 (GMUX), the port will be ifIndex."
|
|
::= { sysCClkSrcEntry 4}
|
|
|
|
sysCClkStationFreq OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
f1544Khz (2), -- DS1
|
|
f2048Khz (3) -- E1
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the frequency of the station clock
|
|
when the source is 'station'.
|
|
The value will be applicable only when the sysCClkSrcMode is
|
|
'station'. "
|
|
::= { sysCClkSrcEntry 5}
|
|
|
|
sysCClkRevertiveTimeout OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The time in seconds in which the system will monitor the higher
|
|
level clock source, before decision to revert to that clock.
|
|
In case the time is zero, revertive mode will be disabled."
|
|
::= { sysCClkSrcEntry 6}
|
|
|
|
sysCClkStationIf OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
g703 (2), --E1 balanced
|
|
rs422 (3), --E1
|
|
g703E1Unbalanced (4),
|
|
g703T1 (5),
|
|
rs422T1 (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the electrical interface connected to the
|
|
station clock, when the source is 'station'.
|
|
The value will be applicable only when the sysCClkSrcMode is
|
|
'station'. "
|
|
::= { sysCClkSrcEntry 7}
|
|
|
|
sysCClkStationCableMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
normal (2),
|
|
yCable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whether both Station clocks get their
|
|
clock from the same source (Y Cable)or each one get its clock independently.
|
|
The value will be applicable only when the sysCClkSrcMode is 'station'. "
|
|
::= { sysCClkSrcEntry 8}
|
|
|
|
sysCClkStationOutState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whether station clock can
|
|
send its clock to another device.
|
|
The value will be applicable only when the sysCClkSrcMode is 'station'. "
|
|
::= { sysCClkSrcEntry 9}
|
|
|
|
sysCClkSsmBased OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whether clock source
|
|
will be selected based on receive clock quality,
|
|
indicated in S1 byte inside SONET/SDH overhead,
|
|
(encoded as SSM - Synchronization Status Messaging).
|
|
It is relevant only for sysCClkSrcIdx=master.
|
|
When the value is Yes, sysCClkSrcMode must be notApplicable."
|
|
::= { sysCClkSrcEntry 10}
|
|
|
|
sysCClkSSubsystemSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
clA (3),
|
|
clB (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the Slot from which the S Subsytem Source
|
|
will be taken.
|
|
The value will be applicable only when the sysCClkSrcMode is
|
|
'sSubsystem'. "
|
|
::= { sysCClkSrcEntry 11}
|
|
|
|
sysCClkRecoveredID OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry indicates the Recovered Clock ID.
|
|
The value will be applicable only when sysCClkSrcMode is 'recovered'."
|
|
::= { sysCClkSrcEntry 12}
|
|
|
|
|
|
sysCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the entries of this table are identical (have the
|
|
same value) for all the configurations (1..255) except
|
|
the TmpCnfg.
|
|
The write operation into the Table Objects is valid only
|
|
for the TmpCnfg entry."
|
|
::= { sysConfig 2}
|
|
|
|
sysCnfgEntry OBJECT-TYPE
|
|
SYNTAX SysCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {sysCnfgIdx}
|
|
::= { sysCnfgTable 1}
|
|
|
|
SysCnfgEntry ::=
|
|
SEQUENCE {
|
|
sysCnfgIdx Integer32,
|
|
sysCMatrixMode INTEGER,
|
|
sysCIsdnFormat INTEGER,
|
|
sysCRoutingOnEth INTEGER,
|
|
sysCAutoConfigEnable INTEGER,
|
|
sysCIntTsAllocMode INTEGER,
|
|
sysCBuPrimaryPort INTEGER,
|
|
sysCEnableLanOverTdm INTEGER,
|
|
sysCSs7FisuSuppression Integer32,
|
|
sysCBuRecMode INTEGER
|
|
}
|
|
|
|
sysCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..255) being
|
|
accessed ; Idx of 255 relates to the TmpCnfg.
|
|
For Gmux2000 the range limitation (1..255) was discarded
|
|
since the Idx is computed as: <IO Card No.> x 1000 + 255."
|
|
::= { sysCnfgEntry 1}
|
|
|
|
sysCMatrixMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
bidirectional (2),
|
|
unidirectional (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the TS Matrix Mode:
|
|
bidirectional - TS Assignment Matrix is symmetric.
|
|
unidirectional - TS Assignment Matrix can be asymmetric.
|
|
notApplicable - for agents that do not support this feature."
|
|
::= { sysCnfgEntry 2}
|
|
|
|
sysCIsdnFormat OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
te (2),
|
|
nt (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ISDN format. This parameter controls the operation mode of
|
|
the ISDN ports.
|
|
te - ISDN timing is derived from the signal received
|
|
from the equipment it is connected to.
|
|
nt - timing of the transmit path is locked to the nodal
|
|
timing source.
|
|
notApplicable - for agents that do not support this feature."
|
|
::= { sysCnfgEntry 3}
|
|
|
|
sysCRoutingOnEth OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
proprietary (3),
|
|
rip2 (4),
|
|
rip1 (5),
|
|
rip1and2 (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mng Routing Protocol on the online CL Ethernet port,
|
|
or on device Ethernet port dedicated for mangement."
|
|
::= { sysCnfgEntry 4}
|
|
|
|
sysCAutoConfigEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables user to enable/disable activating
|
|
the Auto Configuration. When Auto Configuration is activated,
|
|
the device learns its configuration Automatically from the Net
|
|
it is connected to."
|
|
::= { sysCnfgEntry 5}
|
|
|
|
sysCIntTsAllocMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
static (2),
|
|
dynamic (3),
|
|
staticOneToOne(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables user to select the mode of Internal TS
|
|
Allocation.
|
|
static - user has to select for each Dynamic card port, the
|
|
Maximum TSs expected to be connected (including future
|
|
growth). This number will be allocated to the ports,
|
|
so that if number of connected TSs will grow within
|
|
the limits of this Maximum TS limit, no disruption
|
|
of data flow will occur for other ports.
|
|
dynamic- TS allocation is done dynamically according to the
|
|
connected TSs. No future reservations are done. This mode
|
|
may cause data disruption on other ports/slots if user
|
|
will want to change the number of connected TSs for a
|
|
Dynamic card port.
|
|
staticOneToOne - user has to select for each Dynamic card port, the
|
|
Maximum TSs expected to be connected (including future
|
|
growth). In addition, the TSs themselves cannot be higher
|
|
than this defined Maximum (e.g if Maximum TSs=5 user cannot
|
|
selects TSs higher than 5). This mode ensures that if number
|
|
of TSs grow within the limits of this Maximum TS limit, no
|
|
disruption of data flow will occur for other ports AND for
|
|
the selected port itself.
|
|
Default=static(2). "
|
|
::= { sysCnfgEntry 6}
|
|
|
|
sysCBuPrimaryPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noBackup (2),
|
|
e1T1orSerial (3),
|
|
eth (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables the user to configure a Backup mechanism.
|
|
If a backup mechanism exists, it is possible to configure the primary port.
|
|
The traffic will flow via the primary port when the port functionality is OK.
|
|
|
|
In Vmux-2100 device the backup mechanism is relevant for the Main Board only.
|
|
The primary port can be the E1/T1/Serial port or the ETH port. "
|
|
::= { sysCnfgEntry 7}
|
|
|
|
sysCEnableLanOverTdm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
enableAll (2),
|
|
enableVoiceOnly (3),
|
|
enableVoiceAndMng (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables/disables transferring traffic from the LAN port
|
|
to the TDM port. It is possible to enable only part of the traffic on the
|
|
TDM port for security reasons or in order to minimize the bandwidth ."
|
|
::= { sysCnfgEntry 8}
|
|
|
|
sysCSs7FisuSuppression OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SS7 Suppresion is used for SS7 Spoofing.
|
|
The SS7 spoofing terminates the keep alive messages from the local VMUX
|
|
without sending them over the network, thus improving the bandwidth utilization.
|
|
FISU means Fill in Service Unit - Keep alive that is sent when no one is talking
|
|
on the line.
|
|
|
|
This object enables the configuration of the SS7 Keep Alive packet % that will
|
|
be discarded.
|
|
|
|
Legal Values: 0 - No Suppression, 10%, 20%, 30% .. 90%
|
|
|
|
Example: For a value of 10, 1 keep alive packet will be discarded out of
|
|
10 keep alive packets that were supposed to be sent over the network."
|
|
::= { sysCnfgEntry 9}
|
|
|
|
sysCBuRecMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto (2),
|
|
manual (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Recovery Mode. This object determines if after recovery
|
|
of the Primary Link (used in Vmux) it will become on-line again or not:
|
|
auto - automatic. In this case, the failed Link will become
|
|
on-line again after recovery, automatically.
|
|
manual - In this case, the failed Link will not become
|
|
on-line again after recovery but user can manually flip
|
|
to this Link."
|
|
::= { sysCnfgEntry 10}
|
|
|
|
|
|
--System I/O Redundacy Table
|
|
--
|
|
--This table contains all I/O cards/ports that have redundancy,
|
|
--data about the redundant card/port and parameters regarding the
|
|
--redundancy operation.
|
|
--The table indexes are Cnfg and the Primary card&port
|
|
|
|
|
|
sysCRdnTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysCRdnEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Configuration of all Redundant I/O cards and ports.
|
|
The write operation into the table objects is valid only
|
|
for the TmpCnfg.
|
|
A Slot/Port that have no Redundancy, will not exist in this
|
|
table."
|
|
::= { sysConfig 3 }
|
|
|
|
sysCRdnEntry OBJECT-TYPE
|
|
SYNTAX SysCRdnEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An entry in table."
|
|
INDEX { sysCRdnCnfgIdx, sysCRdnPrimeSlot, sysCRdnPrimePort}
|
|
::= { sysCRdnTable 1}
|
|
|
|
SysCRdnEntry ::= SEQUENCE {
|
|
sysCRdnCnfgIdx Integer32,
|
|
sysCRdnPrimeSlot INTEGER,
|
|
sysCRdnPrimePort Integer32,
|
|
sysCRdnSecSlot INTEGER,
|
|
sysCRdnSecPort Integer32,
|
|
sysCRdnMode INTEGER,
|
|
sysCRdnRecMode INTEGER,
|
|
sysCRdnRecTime Integer32,
|
|
sysCRdnHwSwFlip INTEGER,
|
|
sysCRdnRowStatus RowStatus,
|
|
sysCRdnOnline INTEGER,
|
|
sysCRdnSwitchingMode INTEGER,
|
|
sysCRdnFlipUponEvent Integer32,
|
|
sysCRdnLosOrLofTime Integer32,
|
|
sysCRdnEventsTimeWindow Integer32,
|
|
sysCRdnSequenceNumberThreshold Integer32,
|
|
sysCRdnBufferErrorsThreshold Integer32,
|
|
sysCRdnBuffUnderrunTime Integer32,
|
|
sysCRdnPrimePriority INTEGER,
|
|
sysCRdnSecPriority INTEGER,
|
|
sysCRdnWTR Unsigned32,
|
|
sysCRdnName SnmpAdminString,
|
|
sysCRdnTxDownDurationUponFlip Unsigned32
|
|
}
|
|
|
|
sysCRdnCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg(1..255) being
|
|
accessed ; Idx of 255 relates to the TmpCnfg."
|
|
::= { sysCRdnEntry 1 }
|
|
|
|
sysCRdnPrimeSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number of the Primary card of Redundancy.
|
|
The Primary card should be the card that user wishes to be
|
|
the online card (usually the more important one).
|
|
For some Redundancy modes the importance of the redundant
|
|
cards/ports is the same. "
|
|
::= { sysCRdnEntry 2 }
|
|
|
|
sysCRdnPrimePort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number.
|
|
For DXC:
|
|
For external ports the convention used will be:
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
For internal ports the convention used will be:
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
|
|
For MP:
|
|
For external ports, the value will be as that of the port in the
|
|
card. Example: external-3 -> 3
|
|
external-4 -> 4
|
|
For internal ports, the value will be 100 + the port in the
|
|
card. Example: internal-1 -> 101
|
|
internal-4 -> 104
|
|
For IP Bundles, the value will be the Bundle ifIndex. For an IP Bundle
|
|
that is in an External Device (not in this MP), the value will be:
|
|
70,000 + ifIndex of Secondary Bundle.
|
|
|
|
For other products - refer to product specification.
|
|
|
|
100=notApplicable (when Redundancy is at card level)."
|
|
::= { sysCRdnEntry 3 }
|
|
|
|
sysCRdnSecSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The slot number of the Secondary card of Redundancy matching
|
|
the Primary slot."
|
|
::= { sysCRdnEntry 4 }
|
|
|
|
sysCRdnSecPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The port number.
|
|
For DXC:
|
|
For external ports the convention used will be:
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
For internal ports the convention used will be:
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
|
|
For MP:
|
|
For external ports, the value will be as that of the port in the
|
|
card. Example: external-3 -> 3
|
|
external-4 -> 4
|
|
For internal ports, the value will be 100 + the port in the
|
|
card. Example: internal-1 -> 101
|
|
internal-4 -> 104
|
|
For IP Bundles, the value will be the Bundle ifIndex. For an IP Bundle
|
|
that is in an External Device (not in this MP), the value will be: 0.
|
|
|
|
For other products - refer to product specification.
|
|
|
|
100=notApplicable (when Redundancy is at card level)."
|
|
::= { sysCRdnEntry 5 }
|
|
|
|
sysCRdnMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dualCableAIS (2),
|
|
yCable (3),
|
|
dualCableParallelTx (4),
|
|
backup (5),
|
|
singleSlotProtection (6),
|
|
onePlusOne (7),
|
|
oneToOne (8),
|
|
linkAggregation (9), --802.3ad
|
|
manual (10),
|
|
onePlusOneBid (11),
|
|
onePlusOneOpt (12),
|
|
ds0SncProtection (13)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Redundancy Mode.
|
|
DXC supports yCable(3), singleSlotProtection(6) and
|
|
dualCableParallelTx(4)
|
|
MP supports yCable(3), dualCableParallelTx(4), onePlusOne(7)
|
|
and oneToOne(8).(dualCableAIS and backup were planned for MP
|
|
but were not implemented).
|
|
backup - will be used when a port is backup of more than one
|
|
port.
|
|
IPmux: onePlusOne(7) and oneToOne(8) are used for Bundle
|
|
redundancy.
|
|
onePlusOneBid (11) defines 'Bidirectional 1+1 protection'
|
|
onePlusOneOpt (12) defines 'Optimized 1+1 protection'
|
|
ds0SncProtection (13) defines DS0 protection using
|
|
symmetrical DS1 ring configuration"
|
|
::= { sysCRdnEntry 6 }
|
|
|
|
sysCRdnRecMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto (2),
|
|
manual (3),
|
|
nonRevertive(4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Recovery Mode. This object determines if after recovery
|
|
of the failed Primary card/port it will become on-line again or not:
|
|
auto - automatic . In this case, the failed card/port will become
|
|
on-line again after recovery, automatically.
|
|
manual - In this case, the failed card/port will not become
|
|
on-line again after recovery. But, user can manually flip
|
|
to this card/port.
|
|
nonRevertive - same as manual, but here user CANNOT manually flip
|
|
to this card/port. It will become on-line again, only if the
|
|
Secondary/Backup card/port will fail."
|
|
::= { sysCRdnEntry 7 }
|
|
|
|
sysCRdnRecTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Redundancy Recovery Time (sec). After switching to the current
|
|
online card, the next switch can be performed only after a
|
|
minimum time, indicated by this object.
|
|
Valid Values: 0..300, 65535.
|
|
65535=NA.
|
|
This object is applicable only when sysCRdnRecMode=auto."
|
|
::= { sysCRdnEntry 8 }
|
|
|
|
sysCRdnHwSwFlip OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
hw (2),
|
|
sw (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"HW or SW decision for Redundancy Flip.
|
|
This object is applicable only for sysCRdnMode=singleSlotProtection.
|
|
HW - decision is by I/O card
|
|
SW - decision is by CL SW."
|
|
::= { sysCRdnEntry 9 }
|
|
|
|
sysCRdnRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter allows NMS to create/delete entries of this table.
|
|
The possible supported RowStatus values are
|
|
active (1) and destroy (6).
|
|
|
|
For Vmux-2100 the supported values are:
|
|
active (1), createAndGo (4) and destroy (6)."
|
|
::= { sysCRdnEntry 10 }
|
|
|
|
sysCRdnOnline OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
primary (2),
|
|
secondary (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status - who is the Online (current) Redundancy Slot/Port.
|
|
This object shows only the Online Slot/Port regarding the Redundancy.
|
|
mdlSActivity or prtGenActiveStatus of the same Slot/Port may be Offline."
|
|
::= { sysCRdnEntry 11 }
|
|
|
|
sysCRdnSwitchingMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
biDirectional (2), --1+1
|
|
uniDirectional (3), --1:1
|
|
linkAggregation (4) --802.3ad
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines which Self Healing Ring (SHR) SDH ring is used:
|
|
Uni Directional or BiDirectional. The type of the ring
|
|
is defined according to the direction of traffic flow under
|
|
normal working conditions.
|
|
|
|
In Bi Directional ring, the duplex traffic is on the same path
|
|
and transverses the same set of nodes for both directions of transmission.
|
|
In Uni Directional ring, the duplex traffic travels over opposite path
|
|
(per direction) and all the node of the ring are involved.
|
|
|
|
For Uni Directional SHR Protection Switching (Single Ended Switching)
|
|
is controlled by one node of the SDH ring, and does not require a protocol.
|
|
For Bi Directional SHR Protection Switching (Dual Ended switching)
|
|
is controlled by some nodes of the ring and requires a protocol"
|
|
::= { sysCRdnEntry 12 }
|
|
|
|
sysCRdnFlipUponEvent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object allows user to define if Flip to the other port will
|
|
be performed (or not), for certain possible events.
|
|
Each event is represented by a bit. The value of the object is a sum
|
|
of 2**n, according to the bits having '1' value.
|
|
'1' - means that Flip should occur due to this event.
|
|
Bit 0 (LSB) = SD (Signal Degraded).
|
|
For IPmux:
|
|
Bit 0 (LSB) = TDM Line LOS/LOF.
|
|
Bit 1 = Sequence Number.
|
|
Bit 2 = Jitter Buffer errors."
|
|
::= { sysCRdnEntry 13 }
|
|
|
|
sysCRdnLosOrLofTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the time to wait before switching,
|
|
e.g. after failure (as LOF or LOS) is detected on the TDM
|
|
Line.
|
|
For Ipmux time is counted in msec.
|
|
MP uses second units."
|
|
::= { sysCRdnEntry 14 }
|
|
|
|
sysCRdnEventsTimeWindow OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the time window in which
|
|
to count events to trigger protection switching.
|
|
For Ipmux time is counted in seconds."
|
|
::= { sysCRdnEntry 15 }
|
|
|
|
sysCRdnSequenceNumberThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the number of Sequence Number errors
|
|
that should occur in the time window in order to cause switching."
|
|
::= { sysCRdnEntry 16 }
|
|
|
|
sysCRdnBufferErrorsThreshold OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines the number of Buffer undeflow/ overflow events
|
|
occured in the time window that cause switching."
|
|
::= { sysCRdnEntry 17 }
|
|
|
|
sysCRdnBuffUnderrunTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter determines how much time to wait before switching,
|
|
after jitter buffer underrun.
|
|
Switching occurs if no frame arrives within that time.
|
|
For Ipmux time is counted in msec."
|
|
::= { sysCRdnEntry 18 }
|
|
|
|
sysCRdnPrimePriority OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
low (2),
|
|
high (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Primary port priority.
|
|
|
|
In ETX2xx/2xxA:
|
|
When selecting sysCRdnMode = manual (10),
|
|
this parameter determines the forced active port:
|
|
low - means that the secondary port is selected to be active
|
|
high - means that the primary port is selected to be active. "
|
|
::= { sysCRdnEntry 19 }
|
|
|
|
sysCRdnSecPriority OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
low (2),
|
|
high (3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Secondary port priority."
|
|
::= { sysCRdnEntry 20 }
|
|
|
|
sysCRdnWTR OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Redundancy Wait to Restore (sec).
|
|
Valid Values: 0..999, 65535.
|
|
65535=NA.
|
|
When the value <> 65535, the value of sysCRdnRecTime must be 65535."
|
|
::= { sysCRdnEntry 21 }
|
|
|
|
sysCRdnName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A textual name for the redundancy group."
|
|
::= { sysCRdnEntry 22 }
|
|
|
|
sysCRdnTxDownDurationUponFlip OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..30)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines the duration (in seconds) the active
|
|
port transmission is shut down after flip occurs.
|
|
The transmission is shut down and then opened again (after the duration
|
|
defined by this object), in order to cause the other side to flip
|
|
to the new active port.
|
|
0 = no shut-down.
|
|
This object is applicable only when sysCRdnMode = oneToOne(8)
|
|
and mainly when each of the links of our device is connected to a different device."
|
|
::= { sysCRdnEntry 23 }
|
|
|
|
|
|
|
|
--IO Redundancy - Commands
|
|
--This table was moved here, so that its indexes will be defined before,
|
|
--for SNMPc
|
|
|
|
sysSRdnCmdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysSRdnCmdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes commands used for IO Redundancy."
|
|
::= { sysStatus 22 }
|
|
|
|
sysSRdnCmdEntry OBJECT-TYPE
|
|
SYNTAX SysSRdnCmdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {sysCRdnPrimeSlot, sysCRdnPrimePort }
|
|
::= { sysSRdnCmdTable 1}
|
|
|
|
SysSRdnCmdEntry ::=
|
|
SEQUENCE {
|
|
sysSRdnEnforcedChannel INTEGER,
|
|
sysSRdnLockFlip INTEGER,
|
|
sysSRdnManualFlip INTEGER
|
|
}
|
|
|
|
sysSRdnEnforcedChannel OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
noEnforcement (2),
|
|
primary (3),
|
|
secondary (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a command to override all switching considerations
|
|
and enforce use of primary/ secondary connection only.
|
|
noEnforcement - cancels the state of override and goes back to
|
|
usual switching considerations.
|
|
Default = noEnforcement(2)."
|
|
::= {sysSRdnCmdEntry 1 }
|
|
|
|
sysSRdnLockFlip OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a command to lock the Redundancy flip for this redundancy couple.
|
|
Default = off(2)."
|
|
::= {sysSRdnCmdEntry 2 }
|
|
|
|
sysSRdnManualFlip OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a command to move to manual Redundancy flip mode for this redundancy couple.
|
|
Default = off(2)."
|
|
::= {sysSRdnCmdEntry 3 }
|
|
|
|
--System Database operations
|
|
|
|
sysDbaseSanityCheckCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to on(3) will initiate the process
|
|
of Sanity check on the TmpCnfg. Upon completion, the value
|
|
will automatically change to off(2)."
|
|
::= { sysDbase 1 }
|
|
|
|
sysDbaseDownloadCnfgIdxCmd OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute specifies the Id of the target RealCnfg to
|
|
which the TmpCnfg should be transferred. Upon set command,
|
|
the DACS agent will initiate the Sanity-Check process.
|
|
If successful, the actual transfer will be performed.
|
|
If there will be errors, the user will have to perform
|
|
the command again after errors correction.
|
|
The operation is valid only on configuration numbers
|
|
that do not exceed sysSMaxNoOfCnfg."
|
|
::= { sysDbase 2 }
|
|
-- In phase I of DXC and FCD only the value 1 (Cnfg1) is valid.
|
|
|
|
sysDbaseUploadCnfgIdxCmd OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute specifies the Id of the source Cnfg to be
|
|
loaded into the TmpCnfg. Upon set operation the actual
|
|
transfer will be initiated.
|
|
The operation is valid only on configuration numbers
|
|
that do not exceed sysSMaxNoOfCnfg."
|
|
::= { sysDbase 3 }
|
|
-- In phase I of DXC and FCD only the value 1 (Cnfg1) is valid.
|
|
|
|
sysDbaseFlipTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SysDbaseFlipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Dbase Flip time and activation for every configuration."
|
|
::= { sysDbase 4 }
|
|
|
|
sysDbaseFlipEntry OBJECT-TYPE
|
|
SYNTAX SysDbaseFlipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {sysDbaseFlipIdx}
|
|
::= { sysDbaseFlipTable 1}
|
|
|
|
SysDbaseFlipEntry ::=
|
|
SEQUENCE {
|
|
sysDbaseFlipIdx Integer32,
|
|
sysDbaseFlipTime DisplayString,
|
|
sysDbaseFlipActivation INTEGER }
|
|
|
|
sysDbaseFlipIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg being
|
|
the target Configuration."
|
|
::= { sysDbaseFlipEntry 1}
|
|
|
|
sysDbaseFlipTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..255))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the time (HH:MM) when this data
|
|
base will start being used by the Tmp config."
|
|
::= { sysDbaseFlipEntry 2}
|
|
|
|
sysDbaseFlipActivation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable (1),
|
|
enable (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates if the Dbase flip will be
|
|
activated at the time specified for this configuration
|
|
(enable) or not (disable).
|
|
No more than one flip should be enabled for the same time."
|
|
::= { sysDbaseFlipEntry 3}
|
|
|
|
|
|
--Module (card) level of DACS MIB
|
|
|
|
mdlGen OBJECT IDENTIFIER ::= {mdlDacsMux 1}
|
|
mdlCl OBJECT IDENTIFIER ::= {mdlDacsMux 2}
|
|
mdlPs OBJECT IDENTIFIER ::= {mdlDacsMux 3}
|
|
|
|
--DACS module (card) general parameters (common to all cards
|
|
--type)
|
|
|
|
--General Card - Status information table
|
|
--This table is NOT-APPLICABLE for a stand-alone unit
|
|
|
|
mdlSTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { mdlGen 1 }
|
|
|
|
mdlSEntry OBJECT-TYPE
|
|
SYNTAX MdlSEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlSSltIdx }
|
|
::= { mdlSTable 1}
|
|
|
|
MdlSEntry ::=
|
|
SEQUENCE {
|
|
mdlSSltIdx SlotType,
|
|
mdlSCardType CardType,
|
|
mdlSHwVer DisplayString,
|
|
mdlSSwVer DisplayString,
|
|
mdlSAlarmStatus INTEGER,
|
|
mdlSAlarmStatusAll INTEGER,
|
|
mdlSTestStatus INTEGER,
|
|
mdlSHwStatus INTEGER,
|
|
mdlSActivity INTEGER,
|
|
mdlSAlrClearCmd INTEGER,
|
|
mdlSAlrClearAllCmd INTEGER,
|
|
mdlSAlrMaskAll INTEGER,
|
|
mdlSCmd Integer32,
|
|
mdlSReset INTEGER,
|
|
mdlSRebuildFrame INTEGER,
|
|
mdlSBackupSwVer DisplayString,
|
|
mdlSSecondaryBackupSwVer DisplayString,
|
|
mdlSPiggybackVer SnmpAdminString
|
|
}
|
|
|
|
mdlSSltIdx OBJECT-TYPE
|
|
SYNTAX SlotType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify a slot position in the DACS.
|
|
The Kilomux should use enumerated values starting with kmx.
|
|
For IPmux100 use values 1-13, 20."
|
|
::= { mdlSEntry 1}
|
|
|
|
|
|
mdlSCardType OBJECT-TYPE
|
|
SYNTAX CardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the type of the card installed
|
|
in the specific slot position.
|
|
Only PS's are possible in the PS slots.
|
|
Only CL's are possible in the CL slots.
|
|
Only IO modules are possible in the IO slots.
|
|
Kmux card type start with the letter k.
|
|
LA card type start with the letters la."
|
|
::= { mdlSEntry 2}
|
|
|
|
mdlSHwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Hardware version of the
|
|
card installed in the specific slot position."
|
|
::= { mdlSEntry 3 }
|
|
|
|
mdlSSwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Software version of the
|
|
card installed in the specific slot position."
|
|
::= {mdlSEntry 4}
|
|
|
|
|
|
mdlSAlarmStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
major (3),
|
|
minor (4),
|
|
event (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current alarm state only for card level.
|
|
This object will be set to:
|
|
- critical(7): when there is at least one active (ON) critical
|
|
alarm .
|
|
- major (3): when there is no active critical alarm, but there is
|
|
at least one active (ON) major alarm .
|
|
- minor (4): when there is no active major or critical alarm, but
|
|
there is at least one active minor alarm.
|
|
- warning (6): when there is no active major, critical or minor alarm, but
|
|
there is at least one active warning alarm.
|
|
- event (5): when there is no active alarm of another type, but
|
|
there is at least one active event alarm.
|
|
- off(2): when there is no active (ON) alarm (since last clear operation)."
|
|
::= { mdlSEntry 5 }
|
|
|
|
mdlSAlarmStatusAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
major (3),
|
|
minor (4),
|
|
event (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the current card alarm state including the
|
|
lower level: card, port.
|
|
This object will be set to:
|
|
- critical(7): when there is at least one active (ON) critical
|
|
alarm .
|
|
- major (3): when there is no active critical alarm, but there is
|
|
at least one active (ON) major alarm .
|
|
- minor (4): when there is no active major or critical alarm, but
|
|
there is at least one active minor alarm.
|
|
- warning (6): when there is no active major, critical or minor alarm, but
|
|
there is at least one active warning alarm.
|
|
- event (5): when there is no active alarm of another type, but
|
|
there is at least one active event alarm.
|
|
- off(2): when there is no active (ON) alarm (since last clear operation)."
|
|
::= { mdlSEntry 6 }
|
|
|
|
mdlSTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute will be on(3) when there is at least
|
|
one test running on a port of the module; otherwise the value
|
|
will be off(2)."
|
|
::= { mdlSEntry 7 }
|
|
|
|
mdlSHwStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
fail(2),
|
|
ok (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute will be fail(2) when a HW FAIL exists
|
|
on this module (discovered by periodic self test);
|
|
otherwise the value will be ok(3)."
|
|
::= { mdlSEntry 8 }
|
|
|
|
mdlSActivity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
offline (2),
|
|
online (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"notApplicable - when the slot is empty (no module)
|
|
offline(1) - when the module is not active (redundant)
|
|
online (2) - when the module is active ."
|
|
::= { mdlSEntry 9 }
|
|
|
|
mdlSAlrClearCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce a clear
|
|
operation on the card level alarms . Upon completion,
|
|
the value will automatically change to off(2)."
|
|
::= { mdlSEntry 10 }
|
|
|
|
|
|
mdlSAlrClearAllCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce a clear
|
|
operation on card and port level alarms . Upon completion,
|
|
the value will automatically change to off(2)."
|
|
::= { mdlSEntry 11 }
|
|
|
|
mdlSAlrMaskAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"on(3) - will cause masking of all the card level alarms.
|
|
These alarms will not be sent to NMS and will not
|
|
be taken into account for Alarms Status.
|
|
off(2) - will unmask all card level alarms except those
|
|
masked via the mdlAlrMaskTable. "
|
|
::= { mdlSEntry 12 }
|
|
|
|
mdlSCmd OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"General object for any special command at card level.
|
|
0=NotApplicable, for cards that don't support this object.
|
|
|
|
For KML.10(ISDN) card of KM-2100, the object will indicate
|
|
Manual Call Command in Switch mode. It is applicable only when
|
|
for KML.10, prtIsdnSwitchMode=manual.
|
|
KML.10 valid values:
|
|
'1' = noOp, will be used by agents that do not support this
|
|
feature or object (old KM agents)
|
|
'2' = off, Set call command mode to disconnect state. Disconnects the call.
|
|
'3' = on, Set call command mode to connect state. Connects the call.
|
|
|
|
For DXC IO cards, the object will be used for IO Card Reset HW command:
|
|
'2' = off, this will be always the Get value for these cards.
|
|
'3' = on, this is the Set command used to Reset the IO card. Upon
|
|
completing the operation, the value will automatically change to off(2),
|
|
by Agent.
|
|
For Slots that are NOT IO Slots and for empty IO Slots, the Get value will
|
|
be always '0' (NotApplicable). "
|
|
::= { mdlSEntry 13 }
|
|
|
|
|
|
mdlSReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
on (3) --HW
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset action to be performed on the module."
|
|
::= { mdlSEntry 14 }
|
|
|
|
mdlSRebuildFrame OBJECT-TYPE
|
|
SYNTAX INTEGER {notApplicable(1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Applicable only for KiloMux Main Link cards only.
|
|
'2' = off, this will be always the Get value.
|
|
'3' = on, this is the Set command used to Rebuild the Frame.
|
|
Upon completing the operation, the value will automatically change
|
|
to off(2), by Agent."
|
|
::= { mdlSEntry 15}
|
|
|
|
mdlSBackupSwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Backup Software version of the
|
|
card installed in the specific slot position."
|
|
::= {mdlSEntry 16}
|
|
|
|
mdlSSecondaryBackupSwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Secondary Backup Software version of the
|
|
card installed in the specific slot position."
|
|
::= {mdlSEntry 17}
|
|
|
|
mdlSPiggybackVer OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Piggyback version of the
|
|
card installed in the specific slot position."
|
|
::= { mdlSEntry 18 }
|
|
|
|
|
|
--General Card - Configuration table
|
|
--This table is NOT-APPLICABLE for a stand-alone unit
|
|
|
|
mdlCTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { mdlGen 2 }
|
|
|
|
mdlCEntry OBJECT-TYPE
|
|
SYNTAX MdlCEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlCConfigIdx, mdlCSlotIdx }
|
|
::= { mdlCTable 1}
|
|
|
|
MdlCEntry ::= SEQUENCE {
|
|
mdlCConfigIdx Integer32,
|
|
mdlCSlotIdx SlotType,
|
|
mdlCProgCardType CardType,
|
|
mdlCNoOfExtPrt Integer32,
|
|
mdlCNoOfIntPrt Integer32,
|
|
mdlCParam Integer32,
|
|
mdlCAdminStatus INTEGER,
|
|
mdlCActualCardType CardType,
|
|
mdlCOperStatus INTEGER,
|
|
mdlCDetailedStatus BITS,
|
|
mdlCEntPhysicalIndex PhysicalIndexOrZero,
|
|
mdlCReset INTEGER,
|
|
mdlCConfigMismatchReason INTEGER,
|
|
mdlCIpAddressType InetAddressType,
|
|
mdlCIpAddress InetAddress,
|
|
mdlCHardwareFailureReason INTEGER,
|
|
mdlCFanControl INTEGER,
|
|
mdlCFanOperStatus INTEGER
|
|
}
|
|
|
|
mdlCConfigIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Configuration number (1..255)
|
|
referred.
|
|
Value of 255 specifies the TmpCnfg (Scratch)."
|
|
::= { mdlCEntry 1}
|
|
-- In phase 1 only the values 1 (Cnfg1) and 255 (temp) are valid.
|
|
|
|
mdlCSlotIdx OBJECT-TYPE
|
|
SYNTAX SlotType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique number of the slot position
|
|
in which the module is inserted.
|
|
The Kilomux should use enumerated values starting with kmx."
|
|
::= { mdlCEntry 2}
|
|
|
|
|
|
mdlCProgCardType OBJECT-TYPE
|
|
SYNTAX CardType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the card type assigned to the specific
|
|
slot in the common configuration.
|
|
This object is identical for all the configurations (1..255).
|
|
Only the TmpCnf(255) might have a different value.
|
|
The write operation is valid only for the TmpCnfg entry."
|
|
::= { mdlCEntry 3}
|
|
|
|
mdlCNoOfExtPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of external ports in the programmed module of
|
|
the specific slot position"
|
|
::= { mdlCEntry 4}
|
|
|
|
mdlCNoOfIntPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of internal ports in the programmed module of
|
|
the specific slot position."
|
|
::= { mdlCEntry 5}
|
|
|
|
mdlCParam OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"General configuration object at card level (per configuration).
|
|
NotApplicable=0, for cards that don't support this object.
|
|
|
|
For D8U and D16U cards of DXC, the object will indicate
|
|
the port on which BERT will be performed. The port can be
|
|
one of the external ports, any of its associated B1, B2, D ports
|
|
or no port of the card (None=0).
|
|
For port indexes see DXC R6 spec.
|
|
|
|
For Gmux-2000, this parameter used for determining the Gigabit ETH exit port"
|
|
::= {mdlCEntry 6 }
|
|
|
|
|
|
mdlCAdminStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired state of the module.
|
|
|
|
Module adminStatus should be managed for all modules in the shelf.
|
|
When adminStatus is 'down', this module is not operational i.e.
|
|
this module doesn't handle traffic and doesn't generate traps.
|
|
|
|
Setting module adminStatus to up should always succeed (the
|
|
operStatus might remain 'down' as a result of a failure).
|
|
|
|
up
|
|
The desired state for this module is operational.
|
|
|
|
down
|
|
The desired state for this module is disabled.When a managed
|
|
system initializes, all instances start with
|
|
mdlCAdminStatus in the up(1) state. As a result of either
|
|
explicit management action or per configuration information
|
|
retained by the managed system, mdlCAdminStatus is then
|
|
changed to either the 'down' or remains in the 'up' state."
|
|
DEFVAL { up }
|
|
::= { mdlCEntry 7 }
|
|
|
|
mdlCActualCardType OBJECT-TYPE
|
|
SYNTAX CardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object defines actual card type."
|
|
::= { mdlCEntry 8 }
|
|
|
|
mdlCOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
up(1),
|
|
down(2),
|
|
notPresent (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational state of the module.
|
|
|
|
up
|
|
The physical module agrees with the pre-provisioned card type,
|
|
and the configuration of the module succeeded.
|
|
|
|
down
|
|
There are one or more problems/failures with the module.
|
|
Detailed information is contained in the object mdlCDetailedStatus.
|
|
|
|
notPresent
|
|
The module is not detected in the shelf at the moment."
|
|
::= { mdlCEntry 9 }
|
|
|
|
mdlCDetailedStatus OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
initializing (0),
|
|
cardMismatch (1),
|
|
initFailed (2),
|
|
provisionFailed (3),
|
|
selfTestFailed (4),
|
|
commFailure (5),
|
|
bpInterfaceFailure (6),
|
|
configurationMismatch (7),
|
|
noInputPower (8)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The module current status.
|
|
|
|
When moduleOperStatus is down(2), but not as a result of
|
|
setting the moduleAdminStatus to down(2), this object contains
|
|
the failure reason or reasons.
|
|
|
|
The moduleOperStatus value can be up(1) only when all bits of
|
|
this object are cleared.
|
|
|
|
The following failure reasons can be indicated:
|
|
|
|
initializing (0)
|
|
The module initialization procedure is in progress.
|
|
For a MC the start-up time may take a few minutes and the bit
|
|
should be set during this time.
|
|
|
|
cardMismatch (1)
|
|
There is a type mismatch between the pre-provisioned module and
|
|
the actual installed module.
|
|
|
|
initFailed (2)
|
|
A SW download problem from the Main Card to an I/O card.
|
|
|
|
provisionFailed (3)
|
|
Provisioning failure or any other initialization problem of an I/O card.
|
|
|
|
selfTestFailed (4)
|
|
Power-up or periodic diagnostics has detected a H/W malfunction of the card.
|
|
|
|
commFailure (5)
|
|
The MC detects loss of management communication with an I/O card that
|
|
it was previously talking to. In other words, the I/O card completed
|
|
its initialization and already established communication with the MC
|
|
and at some time later the management communication failed.
|
|
|
|
bpInterfaceFailure (6)
|
|
One or more of the module's backplane interfaces has detected bit errors
|
|
or loss of packets.
|
|
|
|
configurationMismatch(7)
|
|
Indication that a configuration mismatch was detected while
|
|
the card has been configured
|
|
|
|
noInputPower(8)
|
|
Indication that module (usually a power inlet) is plugged-in but no power
|
|
cable is attached to it.
|
|
"
|
|
::= { mdlCEntry 10 }
|
|
|
|
mdlCEntPhysicalIndex OBJECT-TYPE
|
|
SYNTAX PhysicalIndexOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object contains index of the related entPhysicalEntry of the
|
|
ENTITY-MIB, see RFC4133. It points the relevant card and not the
|
|
card slot. The agent should build this index accordign to the rules
|
|
that are defined by the inventory.doc document.
|
|
Zero value means 'no entry defined', i.e. the card is not detected
|
|
in its slot."
|
|
::= { mdlCEntry 11 }
|
|
|
|
mdlCReset OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Reset action to be performed on the module.
|
|
Agent should set mdlCReset to off (2) during initialization."
|
|
DEFVAL { off }
|
|
::= { mdlCEntry 12 }
|
|
|
|
|
|
mdlCConfigMismatchReason OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
s128KbpsInSynchronousMode (1), -- 128 kbps in synchronous mode
|
|
s14k4KbpsConfiguration (2), -- 14.4 kbps configuration
|
|
s28k8KbpsConfiguration (3), -- 28.8 kbps configuration
|
|
s48KbpsConfiguration (4), -- 48 kbps configuration
|
|
s56KbpsInSynchronousMode (5), -- 56 kbps in synchronous mode
|
|
s7k2KbpsConfiguration (6), -- 7.2 kbps configuration
|
|
adpcmConfiguration (7), -- ADPCM configuration
|
|
dceOnDteHwInSynchronousMode (8), -- DCE on DTE HW in synchronous mode
|
|
dteOnDceHwInSynchronousMode (9), -- DTE on DCE HW in synchronous mode
|
|
rlbLlbInV110RateAdaptation (10), -- RLB/LLB in V.110 rate adaptation
|
|
swNotSupportingAdvancedSignaling (11), -- SW not supporting advanced signaling
|
|
signalingConfiguration (12), -- signaling configuration
|
|
stratum1WithoutOcxo (13), -- stratum 1 without OCXO
|
|
stratum2WithoutOcxo (14), -- stratum 2 without OCXO
|
|
useOf4TdmBusesInChassis (15), -- use of 4 TDM buses in chassis
|
|
winkStartModeConfiguration (16), -- wink start mode configuration
|
|
other (2147483647)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object details the card configuration mismatch
|
|
in case the object mdlCDetailedStatus is equal to configurationMismatch(7)"
|
|
::= { mdlCEntry 13 }
|
|
|
|
mdlCIpAddressType OBJECT-TYPE
|
|
SYNTAX InetAddressType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object defines type of the mdlCIpAddress as defined
|
|
in the InetAddress MIB: IPv4 or IPv6."
|
|
::= { mdlCEntry 14 }
|
|
|
|
mdlCIpAddress OBJECT-TYPE
|
|
SYNTAX InetAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The object defines card IP address that will be associated
|
|
with the card loopback IP interface."
|
|
::= { mdlCEntry 15 }
|
|
|
|
mdlCHardwareFailureReason OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
ringerVoltageFailure (2),
|
|
fanFailure (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
""
|
|
::= { mdlCEntry 16 }
|
|
|
|
mdlCFanControl OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up (1),
|
|
down (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The desired state of the fan.
|
|
|
|
Module fan control shall manage all fans on the module, if there are more than one.
|
|
When mdlCFanControl is 'up', all module's fans must be in on state.
|
|
When mdlCFanControl is 'down', all module's fans must be in off state.
|
|
|
|
Setting module mdlCFanControl to 'up' should always succeed (if HW enables detection of
|
|
current fan status, the mdlCFanStatus might remain 'down' as a result of a fan failure).
|
|
|
|
up
|
|
The desired state for all module's fans is operational.
|
|
|
|
down
|
|
The desired state for all module's fans is disabled."
|
|
DEFVAL { up }
|
|
::= { mdlCEntry 22 }
|
|
|
|
mdlCFanOperStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
up (1),
|
|
down (2),
|
|
notPresent (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The current operational state of the module's fans. Provides the
|
|
aggregated state of all fans, if there are more than one on the module.
|
|
|
|
up
|
|
All the fans on the module are in operational state and running.
|
|
|
|
down
|
|
All fans on the module are at disabled state, or, if HW enables actual status detection,
|
|
at least one of the fans on the module does not operate as a result of failure.
|
|
|
|
notPresent
|
|
There are no fans on the module - the default value for modules without fans."
|
|
::= { mdlCEntry 23 }
|
|
|
|
--Module level current alarms
|
|
|
|
mdlAlr OBJECT IDENTIFIER ::= {mdlGen 3}
|
|
|
|
mdlAlrTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of card alarms. "
|
|
::= { mdlAlr 1 }
|
|
|
|
mdlAlrEntry OBJECT-TYPE
|
|
SYNTAX MdlAlrEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {mdlAlrSltIdx , mdlAlrIdx}
|
|
::= { mdlAlrTable 1}
|
|
|
|
MdlAlrEntry ::=
|
|
SEQUENCE {
|
|
mdlAlrSltIdx SlotType,
|
|
mdlAlrIdx Integer32,
|
|
mdlAlrCode Integer32,
|
|
mdlAlrState INTEGER, --severity
|
|
mdlAlarmMask INTEGER,
|
|
mdlAlarmInvert INTEGER,
|
|
mdlAlarmOnOff INTEGER,
|
|
mdlAlarmCounter Integer32
|
|
}
|
|
|
|
mdlAlrIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the alarm status
|
|
table.
|
|
Users should use the get next function to read this table
|
|
because the indexes are not consecutive"
|
|
::= { mdlAlrEntry 1}
|
|
|
|
mdlAlrSltIdx OBJECT-TYPE
|
|
SYNTAX SlotType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the desired slot position.
|
|
The Kilomux should use enumerated values starting with kmx."
|
|
::= { mdlAlrEntry 2}
|
|
|
|
mdlAlrCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a code related to a specific
|
|
alarm description. The list of codes and their related
|
|
descriptions will be sent to NMS request (for display purpose)
|
|
by alrGenTable."
|
|
::= { mdlAlrEntry 3 }
|
|
|
|
mdlAlrState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the card alarm severity."
|
|
::= { mdlAlrEntry 4 }
|
|
|
|
mdlAlarmMask OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm Mask is : on/off."
|
|
::= { mdlAlrEntry 5 }
|
|
|
|
mdlAlarmInvert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm Invert is : on/off."
|
|
::= { mdlAlrEntry 6 }
|
|
|
|
mdlAlarmOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm state is : on/off."
|
|
::= { mdlAlrEntry 7}
|
|
|
|
mdlAlarmCounter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter - how many times the alarm occured (ON) since last
|
|
clear operation or since last Reset."
|
|
::= { mdlAlrEntry 8 }
|
|
|
|
mdlAlrMaskTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlAlrMaskEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The list of card masked alarms. "
|
|
::= { mdlAlr 2 }
|
|
|
|
mdlAlrMaskEntry OBJECT-TYPE
|
|
SYNTAX MdlAlrMaskEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {mdlAlrMaskSltIdx}
|
|
::= { mdlAlrMaskTable 1}
|
|
|
|
MdlAlrMaskEntry ::=
|
|
SEQUENCE {
|
|
mdlAlrMaskSltIdx SlotType,
|
|
mdlAlrMask OCTET STRING
|
|
}
|
|
|
|
mdlAlrMaskSltIdx OBJECT-TYPE
|
|
SYNTAX SlotType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the desired slot position.
|
|
The Kilomux should use enumerated values starting with kmx."
|
|
::= { mdlAlrMaskEntry 1}
|
|
|
|
mdlAlrMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8..10))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a mask that indicates which card level
|
|
alarms are masked. The masked alarms (their bit is set to
|
|
'1') are neither sent to the manager, nor taken into account
|
|
for alarm status and LEDs.
|
|
Bit no. = Alarm code
|
|
The bits that do not belong to the card level will be 0.
|
|
This object is applicable only when mdlSAlrMaskAll=off
|
|
(otherwise all card alarms are masked).
|
|
Example: When Alarm having the code 8 is masked,
|
|
the value of this object will be 100 (hex)."
|
|
::= { mdlAlrMaskEntry 2 }
|
|
|
|
|
|
--DACS dcl (Common Logic) card specific parameters
|
|
|
|
mdlClTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlClEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { mdlCl 1 }
|
|
|
|
mdlClEntry OBJECT-TYPE
|
|
SYNTAX MdlClEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlClIdx }
|
|
::= { mdlClTable 1}
|
|
|
|
MdlClEntry ::=
|
|
SEQUENCE {
|
|
mdlClIdx INTEGER,
|
|
mdlClSwchStatus Integer32,
|
|
mdlClLastFlipDate DisplayString,
|
|
mdlClLastFlipTime DisplayString,
|
|
mdlClLastFlipCause DisplayString
|
|
}
|
|
|
|
mdlClIdx OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
clA (3),
|
|
clB (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Cl slot referred."
|
|
::= { mdlClEntry 1}
|
|
|
|
mdlClSwchStatus OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of the switches on
|
|
the referred DCL card.
|
|
Each switch is represented by a bit. The status is a sum
|
|
of 2**n, according to the bits. There are 4 switches:
|
|
bit 0 SP-PAR (LSB) '1' - Default parameters
|
|
bit 1 PSWRD '1' - Password=default
|
|
'0' - Password=user selected
|
|
bit 2 DB-INIT '1' - DB initiated with default
|
|
'0' - DB initiated with NVRAM contents
|
|
bit 3 PC-SP (MSB) '1' - Management by terminal only
|
|
'0' - Management by NMS
|
|
Example: If SP-PAR and PSWRD bits are set ('1'), the value
|
|
will be 3 (2**1 + 2**0).
|
|
When the status of the switches is unknown, the value of
|
|
this object will be 255."
|
|
::= { mdlClEntry 2}
|
|
|
|
mdlClLastFlipDate OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Date when last flip occured.
|
|
The format would be as specified by the sysSDateFormat."
|
|
::= {mdlClEntry 3}
|
|
|
|
mdlClLastFlipTime OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Time when last flip occured."
|
|
::= {mdlClEntry 4}
|
|
|
|
mdlClLastFlipCause OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The cause of last flip."
|
|
::= {mdlClEntry 5}
|
|
|
|
|
|
|
|
--DACS Ps (Power Supply) card specific parameters
|
|
|
|
mdlPsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MdlPsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { mdlPs 1 }
|
|
|
|
mdlPsEntry OBJECT-TYPE
|
|
SYNTAX MdlPsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { mdlPsIdx }
|
|
::= { mdlPsTable 1}
|
|
|
|
MdlPsEntry ::= SEQUENCE {
|
|
mdlPsIdx SlotType,
|
|
mdlPsStatus INTEGER,
|
|
mdlPsTestResult INTEGER,
|
|
mdlPsVoltageCurrent Integer32,
|
|
mdlPsVoltageMin Integer32,
|
|
mdlPsVoltageMax Integer32
|
|
}
|
|
|
|
mdlPsIdx OBJECT-TYPE
|
|
SYNTAX SlotType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the PS card referred."
|
|
::= { mdlPsEntry 1}
|
|
|
|
mdlPsStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notActive (1),
|
|
active (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the status of the PS card."
|
|
::= { mdlPsEntry 2}
|
|
|
|
mdlPsTestResult OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ok (1),
|
|
f12V (2),
|
|
f5V (3),
|
|
fMinus5V (4),
|
|
fFanVoltage (5),
|
|
fMainVoltage (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the result of the PS test.
|
|
ok (1) - the test passed successfully.
|
|
f12V (2) - 12V FAIL was detected.
|
|
f5V (3) - 5V FAIL was detected.
|
|
fMinus5V (4) - Minus 5V FAIL was detected.
|
|
fFanVoltage (5) - Fan Voltage FAIL was detected.
|
|
fMainVoltage(6) - Main Voltage FAIL was detected
|
|
"
|
|
::= { mdlPsEntry 3}
|
|
|
|
mdlPsVoltageCurrent OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Current PS voltage is in Millivolt."
|
|
::= { mdlPsEntry 4 }
|
|
|
|
mdlPsVoltageMin OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Minumum PS voltage in Millivolt."
|
|
::= { mdlPsEntry 5 }
|
|
|
|
mdlPsVoltageMax OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum PS voltage in Millivolt."
|
|
::= { mdlPsEntry 6 }
|
|
|
|
|
|
--Port level of DACS MIB
|
|
|
|
prtGen OBJECT IDENTIFIER ::= {prtDacsMux 1}
|
|
prtT1E1 OBJECT IDENTIFIER ::= {prtDacsMux 2}
|
|
prtHS OBJECT IDENTIFIER ::= {prtDacsMux 3}
|
|
prtSP OBJECT IDENTIFIER ::= {prtDacsMux 4}
|
|
prtDim OBJECT IDENTIFIER ::= {prtDacsMux 5}
|
|
prtI OBJECT IDENTIFIER ::= {prtDacsMux 6} --ISDN port
|
|
prtHdsl OBJECT IDENTIFIER ::= {prtDacsMux 7} --HDSL Line
|
|
prtT3E3 OBJECT IDENTIFIER ::= {prtDacsMux 8} --T3/E3 interface
|
|
|
|
--DACS port general parameters (common to all ports type except SP)
|
|
--The table contains both status and configuration information
|
|
|
|
prtGenParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtGenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { prtGen 1 }
|
|
|
|
prtGenEntry OBJECT-TYPE
|
|
SYNTAX PrtGenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtGenPrtIdx }
|
|
::= { prtGenParamTable 1}
|
|
|
|
PrtGenEntry ::= SEQUENCE {
|
|
prtGenPrtIdx Integer32,
|
|
prtGenSlt INTEGER,
|
|
prtGenExtInt INTEGER,
|
|
prtGenIfIndex Integer32,
|
|
prtGenActiveStatus INTEGER,
|
|
prtGenAlrStatus INTEGER,
|
|
prtGenTestStatus INTEGER,
|
|
prtGenTestMask Integer32,
|
|
prtGenTestCmd Integer32,
|
|
prtGenTestRunning Integer32,
|
|
prtGenType INTEGER,
|
|
prtGenInterfaceType DisplayString,
|
|
prtGenAlrClearCmd INTEGER,
|
|
prtGenAlrMaskAll INTEGER,
|
|
prtGenParamStatus OCTET STRING,
|
|
prtGenRdnStatus INTEGER,
|
|
prtGenTestMaskXP OCTET STRING,
|
|
prtGenTestCmdXP OCTET STRING,
|
|
prtGenTestRunningXP OCTET STRING
|
|
}
|
|
|
|
prtGenPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside/external, inside/internal.
|
|
|
|
In the Kilomux, the port index is calculated as follows:
|
|
100*Slot+Ch. The external Ch numbers are 1..10, and the
|
|
internal Ch numbers are 11..20.
|
|
|
|
In the DXC :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 ."
|
|
::= { prtGenEntry 1}
|
|
|
|
prtGenSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
kmxMlA (103),
|
|
kmxMlB (104),
|
|
kmxCl (105),
|
|
kmxOpt (106),
|
|
kmxIO1 (107),
|
|
kmxIO2 (108),
|
|
kmxIO3 (109),
|
|
kmxIO4 (110),
|
|
kmxIO5 (111),
|
|
kmxIO6 (112),
|
|
kmxIO7 (113),
|
|
kmxIO8 (114),
|
|
kmxIO9 (115),
|
|
kmxIO10(116),
|
|
kmxIO11(117),
|
|
kmxIO12(118),
|
|
standAlone (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the slot where
|
|
the card is inserted in.
|
|
When the unit is stand-alone, this object is not applicable
|
|
and 255 will be used.
|
|
The Kilomux should use the enumerated starting with kmx."
|
|
::= { prtGenEntry 2}
|
|
|
|
prtGenExtInt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
external (2),
|
|
internal (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute describes the type of the designated port.
|
|
Exteral port is a port with a physical connector. Internal
|
|
port might be of two types, one is a composite port which
|
|
collects data of a few external ports into a common
|
|
bandwidth (usually routed trough DS1 link); the other type is
|
|
internal ports which get only part of external port data
|
|
(usually a few DS0's).
|
|
In the Kilomux-2100, the internal(3) value is used for
|
|
composite channels or sub-channels of an ISDN Ch."
|
|
::= { prtGenEntry 3}
|
|
|
|
prtGenIfIndex OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the unique interface number
|
|
assigned to the port. The specific interface of this
|
|
attribute is the same as the interface identified by the
|
|
value of ifindex in MIB-II.If there is no interface for the
|
|
specific prtIdx, the value will be '7fffffff'h."
|
|
::= { prtGenEntry 4}
|
|
|
|
prtGenActiveStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
notUsed (2),
|
|
offLine (3),
|
|
onLine (4),
|
|
offLineRedundancy (5),
|
|
onLineRedundancy (6)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute describes the activity status of the port.
|
|
unknown(1) indicates that the information is not supported.
|
|
notUsed(2) indicates that the port is not connected according
|
|
to the active config.
|
|
offLine(3) indicates that the port is down (not working)
|
|
due to any problem.
|
|
onLine (4) indicates that the port is up (working)
|
|
offLineRedundancy(5) indicates that the port is down because
|
|
it is a redundant port.
|
|
onLineRedundancy (6) indicates that this is a redundant port
|
|
which is up and works as the active link."
|
|
::= { prtGenEntry 5}
|
|
|
|
prtGenAlrStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
major (3),
|
|
minor (4),
|
|
event (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the alarm state at port (ch) agent level.
|
|
This object will be:
|
|
- critical(7): when there is at least one active (ON) critical
|
|
alarm .
|
|
- major (3): when there is no active critical alarm, but there is
|
|
at least one active (ON) major alarm .
|
|
- minor (4): when there is no active major or critical alarm, but
|
|
there is at least one active minor alarm.
|
|
- warning (6): when there is no active major, critical or minor alarm, but
|
|
there is at least one active warning alarm.
|
|
- event (5): when there is no active alarm of another type, but
|
|
there is at least one active event alarm.
|
|
- off(2): when there is no active (ON) alarm (since last clear operation)."
|
|
::= { prtGenEntry 6}
|
|
|
|
prtGenTestStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute will be on(3) when there is at least one test
|
|
in progress (running) on the port; otherwise the value will
|
|
be off(2)."
|
|
::= { prtGenEntry 7}
|
|
|
|
prtGenTestMask OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is a mask which indicates which tests from the
|
|
'prtGenTestCmd' list are allowed for the selected port.
|
|
If a specific test is allowed, its respective bit will be SET
|
|
in the mask :
|
|
|
|
TEST BIT
|
|
----------- ---
|
|
localLoop 1
|
|
remoteLoop 2
|
|
bert 3
|
|
plb 4
|
|
inband 5
|
|
|
|
prbs 8
|
|
loop2-v54 (RLB) 9
|
|
loop3-v54 (LLB) 10
|
|
|
|
Tone injection 13
|
|
Tx-plb 14
|
|
Tx-llb 15
|
|
DTE loop (HSSI) 16
|
|
|
|
HDSL-Tx-Inband 20
|
|
HDSL-Rx-Inband 21
|
|
Monitor 22 (test port)
|
|
User Line Loopback 23
|
|
|
|
Rem-Loop-on-Rem-Unit 25
|
|
LBBD 26
|
|
LB1 27
|
|
LB2 28
|
|
BERT-on-Rem-Unit 29
|
|
TS Remote Loop 30
|
|
LLB-on-Rem-Unit 31
|
|
|
|
e.g : If the return value is 3 -> 0000000000000011 ->
|
|
Bits 1 & 2 are set -> the allowed tests are :
|
|
local-loop
|
|
remote-loop "
|
|
::= { prtGenEntry 8}
|
|
|
|
|
|
prtGenTestCmd OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to a value as detailed furter on
|
|
(except 0) will initiate a test on the specific port,
|
|
if the operation is allowed (according to TestMask).
|
|
If the operation is not allowed, the mux will ignore the
|
|
operation.
|
|
The test/s requested will be set according to the respective
|
|
bit:
|
|
TEST BIT
|
|
----------- ---
|
|
localLoop 1
|
|
remoteLoop 2
|
|
bert 3
|
|
plb 4
|
|
inband 5
|
|
|
|
prbs 8
|
|
loop2-v54 (RLB) 9
|
|
loop3-v54 (LLB) 10
|
|
|
|
Tone injection 13
|
|
Tx-plb 14
|
|
Tx-llb 15
|
|
DTE loop (HSSI) 16
|
|
|
|
HDSL-Tx-Inband 20
|
|
HDSL-Rx-Inband 21
|
|
Monitor 22 (test port)
|
|
User Line Loopback 23
|
|
|
|
Rem-Loop-on-Rem-Unit 25
|
|
LBBD 26
|
|
LB1 27
|
|
LB2 28
|
|
BERT-on-Rem-Unit 29
|
|
TS Remote Loop 30
|
|
LLB-on-Rem-Unit 31
|
|
|
|
e.g : If the requested value is 3 -> 0000000000000011 ->
|
|
Bits 1 & 2 are set -> the requested tests are :
|
|
local-loop
|
|
remote-loop
|
|
|
|
Setting this object to stop (value=0 ; all bits are 0),
|
|
will stop all the user requested tests running on the
|
|
selected port; it will NOT stop the tests initiated by
|
|
the system."
|
|
::= { prtGenEntry 9}
|
|
|
|
prtGenTestRunning OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates which tests are running currently on
|
|
the selected port (initiated by user and/or by the system).
|
|
If a specific test is currently running on the port, its
|
|
respective bit will be SET:
|
|
|
|
TEST BIT
|
|
----------- ---
|
|
localLoop 1
|
|
remoteLoop 2
|
|
bert 3
|
|
plb 4
|
|
llb 5
|
|
txInband 6
|
|
rxInband 7
|
|
prbs 8
|
|
loop2-v54 (RLB) 9
|
|
loop3-v54 (LLB) 10
|
|
DDS DSU loop 11
|
|
DDS CSU loop 12
|
|
Tone injection 13
|
|
Tx-plb 14
|
|
Tx-llb 15
|
|
DTE loop (HSSI) 16
|
|
Local DTE loop (HSSI)17
|
|
Local Line loop (HSSI)18
|
|
Remote Line loop (HSSI)19
|
|
HDSL-Tx-Inband 20
|
|
HDSL-Rx-Inband 21
|
|
Monitor 22 (test port)
|
|
User Line Loopback 23
|
|
Network Line Loopback 24
|
|
Rem-Loop-on-Rem-Unit 25
|
|
LBBD 26
|
|
LB1 27
|
|
LB2 28
|
|
BERT-on-Rem-Unit 29
|
|
TS Remote Loop 30
|
|
LLB-on-Rem-Unit 31
|
|
|
|
e.g : If the return value is 3 -> 0000000000000011 ->
|
|
Bits 1 & 2 are set -> the running tests are :
|
|
local-loop
|
|
remote-loop
|
|
llb (Bit 5) - can be initiated by system only! "
|
|
::= { prtGenEntry 10}
|
|
|
|
|
|
prtGenType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
t1 (2),
|
|
e1 (3),
|
|
hs (4),
|
|
t1Csu (5),
|
|
t1Dsu (6),
|
|
e1Ltu (7),
|
|
e1Dsu (8),
|
|
hdsl (9),
|
|
sp (10),
|
|
t1F (11), --T1 Fiber-optic
|
|
e1F (12), --E1 Fiber-optic
|
|
dim (13),
|
|
isdn (14),
|
|
t3 (15),
|
|
e3 (16),
|
|
t3f (17),
|
|
e3f (18),
|
|
idsl (19),
|
|
stm1 (20),
|
|
vc4 (21),
|
|
vc12 (22),
|
|
msdsl (23),
|
|
vc11 (24),
|
|
vc3 (25),
|
|
soh (26),
|
|
eth (27),
|
|
shdsl (28),
|
|
other (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object describes the type of the selected port.
|
|
idsl - applicable for external ports of HS-U cards (of DXC) when
|
|
interface is LT-1."
|
|
::= { prtGenEntry 11}
|
|
|
|
prtGenInterfaceType OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique HW interface type of the
|
|
selected port.
|
|
Examples:
|
|
- for T1 cards: DSU, CSU
|
|
- for E1 cards: DSU, LTU
|
|
- for HS cards: v35, rs422, x21
|
|
etc..."
|
|
::= { prtGenEntry 12}
|
|
|
|
prtGenAlrClearCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noOp (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this attribute to ON, will enforce a clear
|
|
operation on the port level alarms . Upon completion,
|
|
the value will automatically change to off(2).
|
|
noOp - will be used by agents that do not support this
|
|
feature or object."
|
|
::= { prtGenEntry 13 }
|
|
|
|
prtGenAlrMaskAll OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noOp (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"on(3) - will mask all the alarms of the selected port
|
|
off(2)- will unmask all alarms of the selected port except
|
|
the ones selected by the prtAlrMaskTable.
|
|
noOp - will be used by agents that do not support this
|
|
feature or object."
|
|
::= { prtGenEntry 14 }
|
|
|
|
prtGenParamStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates Status of parameters specific to the
|
|
selected port.
|
|
- For a port that has no special status or is supported
|
|
by prtSExHsfStatTable - 1 Octet: 00hex
|
|
|
|
- For HS cards (Dxc cards) - 1 octet:
|
|
Bit 7 (MSB)..Bit 2 = 0 (NA)
|
|
Bit 0 and 1 indicates RTS control signal state:
|
|
Bit 1: '1'=active ; '0'=notActive
|
|
Bit 0 (LSB): '1'=unknown ; '0'=NA
|
|
|
|
- For HS-U/1 external port (MP card, used in FCD-M) - 1 Octet:
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
|________| |__| |__|
|
|
spare modem sync
|
|
|
|
modem: 00 = other sync: 00 = not sync
|
|
01 = unknown 01 = sync
|
|
10 = ASMi-31/2 10 = reserved
|
|
11 = reserved 11 = reserved
|
|
|
|
- For VC-6, VC-12, VC-12/6 external ports - 1 Octet :
|
|
Bit 7 (MSB)..Bit 2 = 0 (NA)
|
|
Bit 1: Tx Signaling '1'=On ; '0'=Off
|
|
Bit 0 (LSB): Rx Signaling '1'=On ; '0'=Off
|
|
|
|
- For VC-2/R2(FXS) external ports - 1 Octet :
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|_| |_________|
|
|
Call Call State
|
|
Direction
|
|
|
|
Bit 7 (MSB) and Bit 6 : Call Direction
|
|
00 - Incoming
|
|
01 - Outgoing
|
|
Bit 5..Bit 0: Call State
|
|
000000 - Idle
|
|
000001 - Seized
|
|
000010 - Both-Way Conflict
|
|
000011 - Seizure Ack
|
|
000100 - Answered
|
|
000101 - Clear Backward
|
|
000110 - Clear Forward
|
|
000111 - Blocked
|
|
001000 - Fault
|
|
001001 - Fault 3
|
|
001010 - Fault 4
|
|
001011 - Fault 5
|
|
001100 - Fault 6
|
|
001101 - Fault 7
|
|
|
|
- For ML-20 external port - 3 Octets :
|
|
- 1 MS Octet will represent the Real Rate used:
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|___| |_______|
|
|
spare Rate
|
|
|
|
Valid values: 0..31, meaning 0..31x64Kbps
|
|
Invalid values: 32..255.
|
|
- 2 LS Octets will represent the Status of 7 Control
|
|
Signals:
|
|
Signal - --- CTS DSR DCD RJ TM DTR RTS
|
|
Bit - 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0
|
|
Octet - 2 3 (LS)
|
|
'---' will always have the value 00
|
|
Rest of the Signals (2 bits each) can have the following
|
|
values:
|
|
00=NA ; 01=Unused ; 10=Off ; 11=On
|
|
|
|
- For ML-H/E1, ML-H/1/E1, ML-H/S/E1 internal port - 1 Octet
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|___________|
|
|
spare Mode of Operation
|
|
|
|
Mode of Operation: '1'=Central ; '0'=Remote
|
|
|
|
- For KM2100, KVF.5 cards - indicates the status of A and B signaling
|
|
for each internal channel.
|
|
1 Octet:
|
|
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|_____| |_| |_|
|
|
spare B A
|
|
|
|
Bit 0 (LSB) and Bit 1 : A status
|
|
Bit 2 and Bit 3 : B status
|
|
|
|
00 - Off
|
|
01 - On
|
|
11 - Unknown
|
|
|
|
- For FCD-W, NETWORK and USER ports - 1 Octet
|
|
Status of Control Signals: '1'=On ; '0'=Off or when not applicable
|
|
|
|
Bit - 7 6 5 4 3 2 1 0
|
|
|
|
Bit 7 (MSB) - Signal Loss (applicable only for G.703 interface)
|
|
Bit 6 - CONTROL (applicable only for X.21 interface)
|
|
Bit 5 - INDICATION (applicable only for X.21 interface)
|
|
Bit 4 - DSR (applicable only for V.35 interface)
|
|
Bit 3 - RTS (applicable only for V.35 interface)
|
|
Bit 2 - CTS (applicable only for V.35 interface)
|
|
Bit 1 - DTR (applicable only for V.35 interface)
|
|
Bit 0 - DCD (applicable only for V.35 interface)
|
|
|
|
- For DXC R6 , D8U, D16U External ports - 1 Octet
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
|________| |__| |__|
|
|
spare modem sync
|
|
|
|
modem: 00 = other sync: 00 = not sync
|
|
01 = unknown 01 = sync
|
|
10 = ASMi-31/2 10 = reserved
|
|
11 = reserved 11 = reserved
|
|
|
|
- For DXC DE1-HDSL, DT1-HDSL, D16GSDSL, D8SL External ports - 2 Octets
|
|
|
|
MSB octet: far-end modem channel interface
|
|
LSB octet: Sub Link existence (Y/N), far-end modem type,
|
|
synchronization with far-end modem
|
|
|
|
MSB octet: 0000 0000 = no interface
|
|
0000 0001 = db15 (X21)
|
|
0000 0010 = IR-IP
|
|
0000 0011 = IR-ETH-Q
|
|
0000 0100 = V35
|
|
0000 0101 = ETH-RJ45
|
|
0000 0110 = G703
|
|
0000 0111 = db25 (RS530)
|
|
0000 1000 = ETH-BNC
|
|
0000 1001 = E1(Balanced)
|
|
0000 1010 = E1(Unbalanced)
|
|
0000 1011 = IR-ETH-QN
|
|
Rest of the combinations: reserved
|
|
|
|
LSB octet:
|
|
|
|
Bit 7 6 5 4 3 2 1 0 LSB
|
|
| |___________| |__|
|
|
SL modem sync
|
|
or Box material
|
|
|
|
SL: modem: 00000 = other sync: 00 = not sync
|
|
0=not exist 00001 = unknown 01 = sync
|
|
1=exists 00010 = ASMi-31/2 10 = reserved
|
|
00011 = HCD-E1 11 = reserved
|
|
Box material 00100 = HTU-E1
|
|
(for D8SL card): 00101 = HTU-2
|
|
0=metal 00110 = ASMi-52 SA/2W/Slave
|
|
1=plastic 00111 = ASMi-52 SA/2W/Master
|
|
01000 = ASMi-52/CQ card of LRS-24
|
|
01001 = ASMi-52/CD card of LRS-24
|
|
01010 = D16GSDSL card of DXC-3000
|
|
01011 = LRS-52
|
|
01100 = FCD
|
|
01110 = D8GSDSL card of DXC-3000
|
|
01111 = ASMi-52A
|
|
Rest = reserved "
|
|
::= { prtGenEntry 15}
|
|
|
|
prtGenRdnStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if this port is part of a redundant pair and in
|
|
this case, if it is On or Off.
|
|
|
|
none(1) - No redundancy or Not Applicable
|
|
off (2) - the port is part of a redundant pair and it is Off from
|
|
Redundancy point of view (not the port used).
|
|
on (3) - the port is part of a redundant pair and it is On from
|
|
Redundancy point of view (it is the port used)."
|
|
::= { prtGenEntry 16 }
|
|
|
|
prtGenTestMaskXP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is an Expanded test mask of the prtGenTestMask object.
|
|
The prtGenTestMask object reached its maximum, being an Integer with 31 bits.
|
|
This object indicates which tests from the 'prtGenTestCmdXP' list are
|
|
allowed for the selected port.
|
|
If a specific test is allowed, its respective bit will be SET
|
|
in the mask :
|
|
|
|
TEST BIT
|
|
----------- ---
|
|
localLoop 1 =LSB
|
|
remoteLoop 2
|
|
bert 3
|
|
plb 4
|
|
inband 5
|
|
|
|
prbs 8
|
|
loop2-v54 (RLB) 9
|
|
loop3-v54 (LLB) 10
|
|
|
|
Tone injection 13
|
|
Tx-plb 14
|
|
Tx-llb 15
|
|
DTE loop (HSSI) 16
|
|
|
|
HDSL-Tx-Inband 20
|
|
HDSL-Rx-Inband 21
|
|
Monitor 22 (test port)
|
|
User Line Loopback 23
|
|
|
|
Rem-Loop-on-Rem-Unit 25
|
|
LBBD 26
|
|
LB1 27
|
|
LB2 28
|
|
BERT-on-Rem-Unit 29
|
|
TS Remote Loop 30
|
|
LLB-on-Rem-Unit 31
|
|
Downstream-AIS 32
|
|
Upstream-AIS 33
|
|
Send-RDI 34
|
|
Test Per TS 35
|
|
|
|
e.g : If the return value is 00000003 hex ->
|
|
Bits 1 & 2 are set -> the allowed tests are :
|
|
local-loop
|
|
remote-loop "
|
|
::= { prtGenEntry 17}
|
|
|
|
|
|
prtGenTestCmdXP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is an Expanded test command of the prtGenTestCmd object.
|
|
The prtGenTestCmd object reached its maximum, being an Integer with 31 bits.
|
|
Setting this object to a value as detailed furter on
|
|
(except 0) will initiate a test on the specific port,
|
|
if the operation is allowed (according to TestMaskXP).
|
|
If the operation is not allowed, the mux will ignore the
|
|
operation.
|
|
The test/s requested will be set according to the respective
|
|
bit:
|
|
TEST BIT
|
|
----------- ---
|
|
localLoop 1 =LSB
|
|
remoteLoop 2
|
|
bert 3
|
|
plb 4
|
|
inband 5
|
|
|
|
prbs 8
|
|
loop2-v54 (RLB) 9
|
|
loop3-v54 (LLB) 10
|
|
|
|
Tone injection 13
|
|
Tx-plb 14
|
|
Tx-llb 15
|
|
DTE loop (HSSI) 16
|
|
|
|
HDSL-Tx-Inband 20
|
|
HDSL-Rx-Inband 21
|
|
Monitor 22 (test port)
|
|
User Line Loopback 23
|
|
|
|
Rem-Loop-on-Rem-Unit 25
|
|
LBBD 26
|
|
LB1 27
|
|
LB2 28
|
|
BERT-on-Rem-Unit 29
|
|
TS Remote Loop 30
|
|
LLB-on-Rem-Unit 31
|
|
Downstream-AIS 32
|
|
Upstream-AIS 33
|
|
Send-RDI 34
|
|
Test Per TS 35
|
|
|
|
e.g : If the requested value is 00000003 hex ->
|
|
Bits 1 & 2 are set -> the requested tests are :
|
|
local-loop
|
|
remote-loop
|
|
|
|
Setting this object to stop (value=0 ; all bits are 0),
|
|
will stop all the user requested tests running on the
|
|
selected port; it will NOT stop the tests initiated by
|
|
the system."
|
|
::= { prtGenEntry 18}
|
|
|
|
prtGenTestRunningXP OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This is an Expanded object of the prtGenTestRunning object.
|
|
The prtGenTestRunning object reached its maximum, being an Integer with 31 bits.
|
|
This object indicates which tests are running currently on
|
|
the selected port (initiated by user and/or by the system).
|
|
If a specific test is currently running on the port, its
|
|
respective bit will be SET:
|
|
|
|
TEST BIT
|
|
----------- ---
|
|
localLoop 1 =LSB
|
|
remoteLoop 2
|
|
bert 3
|
|
plb 4
|
|
llb 5
|
|
txInband 6
|
|
rxInband 7
|
|
prbs 8
|
|
loop2-v54 (RLB) 9
|
|
loop3-v54 (LLB) 10
|
|
DDS DSU loop 11
|
|
DDS CSU loop 12
|
|
Tone injection 13
|
|
Tx-plb 14
|
|
Tx-llb 15
|
|
DTE loop (HSSI) 16
|
|
Local DTE loop (HSSI)17
|
|
Local Line loop (HSSI)18
|
|
Remote Line loop (HSSI)19
|
|
HDSL-Tx-Inband 20
|
|
HDSL-Rx-Inband 21
|
|
Monitor 22 (test port)
|
|
User Line Loopback 23
|
|
Network Line Loopback 24
|
|
Rem-Loop-on-Rem-Unit 25
|
|
LBBD 26
|
|
LB1 27
|
|
LB2 28
|
|
BERT-on-Rem-Unit 29
|
|
TS Remote Loop 30
|
|
LLB-on-Rem-Unit 31
|
|
Downstream-AIS 32
|
|
Upstream-AIS 33
|
|
Send-RDI 34
|
|
Test Per TS 35
|
|
|
|
e.g : If the return value is 00000003 hex ->
|
|
Bits 1 & 2 are set -> the running tests are :
|
|
local-loop
|
|
remote-loop
|
|
llb (Bit 5) - can be initiated by system only! "
|
|
::= { prtGenEntry 19}
|
|
|
|
|
|
--prtGenTestDuration - Setting Duration of tests
|
|
|
|
prtGenTestDurationTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtGenTestDurationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { prtGen 2 }
|
|
|
|
prtGenTestDurationEntry OBJECT-TYPE
|
|
SYNTAX PrtGenTestDurationEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtGenTestPrtIdx, prtGenTestIdx }
|
|
::= { prtGenTestDurationTable 1}
|
|
|
|
PrtGenTestDurationEntry ::=
|
|
SEQUENCE {
|
|
prtGenTestPrtIdx Integer32,
|
|
prtGenTestIdx INTEGER,
|
|
prtGenTestDuration Integer32
|
|
}
|
|
|
|
prtGenTestPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside/external, inside/internal.
|
|
|
|
In the Kilomux, the port index is calculated as follows:
|
|
100*Slot+Ch. The external Ch numbers are 1..10, and the
|
|
internal Ch numbers are 11..20.
|
|
|
|
In the DXC :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 ."
|
|
::= { prtGenTestDurationEntry 1}
|
|
|
|
prtGenTestIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
localLoop (1),
|
|
remoteLoop (2),
|
|
bert (3),
|
|
plb (4),
|
|
rlb (5),
|
|
llb (6),
|
|
toneInjection (7),
|
|
txInband (8),
|
|
rxInband (9),
|
|
remLoopOnRemUnit (10),
|
|
bertOnRemUnit (11),
|
|
llbOnRemUnit (12),
|
|
|
|
txPlb (14),
|
|
txLlb (15),
|
|
dteLoop (16), --HSSI
|
|
|
|
hdslTxInband (20),
|
|
hdslRxInband (21),
|
|
monitor (22),
|
|
userLineLoopback(23),
|
|
|
|
lbbd (26),
|
|
lb1 (27),
|
|
lb2 (28),
|
|
|
|
tsRemoteLoop (30),
|
|
|
|
downstreamAis(32),
|
|
upstreamAis (33),
|
|
sendRdi (34)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the test, the duration refers. "
|
|
::= { prtGenTestDurationEntry 2}
|
|
|
|
prtGenTestDuration OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the maximum duration of executing
|
|
a test on the specific port. This entry applies to the
|
|
specified test . The resolution will be a minute, and the
|
|
maximum duration is limited to 30 minutes .
|
|
A zero value specifies no time limitation.
|
|
When the test isn't active the agent initiates this object to
|
|
2 min. when the duration is needed and to 0 if it's not
|
|
required."
|
|
::= { prtGenTestDurationEntry 3}
|
|
|
|
|
|
--prtGen TS (TimeSlot) Assignment Table - for all ports of IO cards
|
|
|
|
prtGenTsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtGenTsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table's Objects is valid only
|
|
for the TmpCnfg entry (Scratch),exept some products
|
|
which enable direct writing to the ActiveCnfg.
|
|
This is written in the respective product's spec. "
|
|
::= { prtGen 3}
|
|
|
|
prtGenTsEntry OBJECT-TYPE
|
|
SYNTAX PrtGenTsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtGenTsCnfgIdx, prtGenTsPrtIdx, prtGenTsIdx }
|
|
::= { prtGenTsTable 1}
|
|
|
|
PrtGenTsEntry ::=
|
|
SEQUENCE {
|
|
prtGenTsCnfgIdx Integer32,
|
|
prtGenTsPrtIdx Integer32,
|
|
prtGenTsIdx Integer32,
|
|
prtGenTsType INTEGER,
|
|
prtGenTsIConPrt Integer32,
|
|
prtGenTsIConTs Integer32
|
|
}
|
|
|
|
prtGenTsCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..255) being
|
|
accessed.
|
|
Idx of 255 relates to the TmpCnfg. "
|
|
::= { prtGenTsEntry 1}
|
|
|
|
|
|
prtGenTsPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside,
|
|
SP.
|
|
In the DXC :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 ."
|
|
::= { prtGenTsEntry 2}
|
|
|
|
prtGenTsIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique time slot position.
|
|
The valid time slots are
|
|
1..25 for T1 Card (25=Fbit)
|
|
0..31 for E1 or HS Card .
|
|
In G732S-E1 lines time slot 16 is not valid for data,
|
|
it is dedicated for multiframe synchronization bits
|
|
and voice signaling."
|
|
::= { prtGenTsEntry 3}
|
|
|
|
prtGenTsType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
voice (2),
|
|
data (3),
|
|
vcMP (4),
|
|
nc (5),
|
|
mng (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The type of Timeslot.
|
|
If the source or destination port is an HS port,'TS Type'
|
|
must be 'data'.
|
|
nc - means that this TimeSlot is not connected.
|
|
voice, data, vcMP - also mean that this TS is connected.
|
|
mng - means that this TS is dedicated to Management (not
|
|
connected to another port."
|
|
|
|
::= { prtGenTsEntry 4}
|
|
|
|
prtGenTsIConPrt OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the internally (In Mux)
|
|
connected port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside,
|
|
SP.
|
|
* The outside ports will be the T1/E1 cards ports.
|
|
The convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
for a stand-alone unit, the IO slot will be considered 1.
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside ports will be for example, the HS cards ports.
|
|
The convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
for a stand-alone unit, the IO slot will be considered 1.
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
* noConnection - will be indicated as 10 for DXC and FCD-E1/T1.
|
|
- will be indicated as 100 for FCD-E1/I and SMODs.
|
|
* Split TS (same TS is Split to several ports) - 11.
|
|
* notApplicable- will be indicated as 100 for LRS IMODs.
|
|
|
|
All HS port's timeslots must have the same destination
|
|
port."
|
|
::= {prtGenTsEntry 5}
|
|
|
|
prtGenTsIConTs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique time slot position.
|
|
The valid time slots are
|
|
1..25 for T1 Card (25=Fbit)
|
|
0..31 for E1 (or HS) Card.
|
|
In G732S-E1 lines time slot 16 is not valid for data, it is
|
|
dedicated for multiframe synchronization bits and voice
|
|
signaling.
|
|
* For DXC: All HS port's timeslots must start with Timeslot
|
|
no.1 "
|
|
::= {prtGenTsEntry 6}
|
|
|
|
--Port current alarms table
|
|
|
|
prtAlr OBJECT IDENTIFIER ::= {prtGen 4}
|
|
|
|
prtSAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { prtAlr 1 }
|
|
|
|
prtSAlarmEntry OBJECT-TYPE
|
|
SYNTAX PrtSAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtSAlarmPrtIdx, prtSAlarmIdx}
|
|
::= { prtSAlarmTable 1}
|
|
|
|
PrtSAlarmEntry ::= SEQUENCE {
|
|
prtSAlarmPrtIdx Integer32,
|
|
prtSAlarmIdx Integer32,
|
|
prtSAlarmCode Integer32,
|
|
prtSAlarmState INTEGER,
|
|
prtSAlarmMask INTEGER,
|
|
prtSAlarmInvert INTEGER,
|
|
prtSAlarmOnOff INTEGER,
|
|
prtSAlarmCounter Integer32
|
|
}
|
|
|
|
prtSAlarmIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an entry in the alarm status
|
|
table.
|
|
Users should use the get next function to read this table
|
|
because the indexes are not consecutive."
|
|
::= { prtSAlarmEntry 1}
|
|
|
|
prtSAlarmPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside/external, inside/internal.
|
|
|
|
In the Kilomux, the port index is calculated as follows:
|
|
100*Slot+Ch. The external Ch numbers are 1..10, and the
|
|
internal Ch numbers are 11..20.
|
|
|
|
In the DXC :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 ."
|
|
::= { prtSAlarmEntry 2}
|
|
|
|
prtSAlarmCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a code related to a specific
|
|
alarm description. The list of codes and their related
|
|
descriptions will be sent to NMS request (for display purpose)
|
|
by alrGenTable."
|
|
::= { prtSAlarmEntry 3 }
|
|
|
|
prtSAlarmState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port alarm severity."
|
|
::= { prtSAlarmEntry 4 }
|
|
|
|
prtSAlarmMask OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm Mask is : on/off."
|
|
::= { prtSAlarmEntry 5 }
|
|
|
|
prtSAlarmInvert OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm Invert is : on/off."
|
|
::= { prtSAlarmEntry 6 }
|
|
|
|
prtSAlarmOnOff OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm state is : on/off."
|
|
::= { prtSAlarmEntry 7 }
|
|
|
|
prtSAlarmCounter OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A counter - how many times the alarm occured (ON) since last
|
|
clear operation or since last Reset."
|
|
::= { prtSAlarmEntry 8 }
|
|
|
|
prtAlrMaskTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtAlrMaskEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { prtAlr 2 }
|
|
|
|
prtAlrMaskEntry OBJECT-TYPE
|
|
SYNTAX PrtAlrMaskEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtAlrMaskPrtIdx}
|
|
::= { prtAlrMaskTable 1}
|
|
|
|
PrtAlrMaskEntry ::=
|
|
SEQUENCE {
|
|
prtAlrMaskPrtIdx Integer32,
|
|
prtAlrMask OCTET STRING
|
|
}
|
|
|
|
|
|
prtAlrMaskPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside/external, inside/internal.
|
|
|
|
In the Kilomux, the port index is calculated as follows:
|
|
100*Slot+Ch. The external Ch numbers are 1..10, and the
|
|
internal Ch numbers are 11..20.
|
|
|
|
In the DXC :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 ."
|
|
::= { prtAlrMaskEntry 1}
|
|
|
|
prtAlrMask OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (8))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a mask that indicates which port level
|
|
alarms are masked. The masked alarms (their bit is set to
|
|
'1') are neither sent to the manager, nor taken into account
|
|
for alarm status and LEDs.
|
|
Bit no. = Alarm code
|
|
The bits that do not belong to the port level will be 0.
|
|
This object is applicable only when prtGenAlrMaskAll=off
|
|
(otherwise all port alarms are masked).
|
|
Example: When Alarms having the codes 31 and 40 are masked,
|
|
the value of this object will be 10080000000 (hex)."
|
|
::= { prtAlrMaskEntry 2 }
|
|
|
|
|
|
--Port BERT table
|
|
|
|
|
|
prtBertTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtBertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table includes the BERT parameters, counters and
|
|
commands.
|
|
The configurable parameters:
|
|
- prtBertPattern
|
|
- prtBertInjectRate
|
|
- prtBertTs
|
|
- prtBertDirection
|
|
are not Set per configuration (same for all Configurations)
|
|
but start being applied by the Agent only upon successful
|
|
Update/Download operation. Therefore, Set will enter the
|
|
values to the Temporary Configuration of the agent, while
|
|
Get will get the values of the Active Configuration."
|
|
::= { prtGen 5 }
|
|
|
|
prtBertEntry OBJECT-TYPE
|
|
SYNTAX PrtBertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtBertPrtIdx}
|
|
::= { prtBertTable 1}
|
|
|
|
PrtBertEntry ::= SEQUENCE {
|
|
prtBertPrtIdx Integer32,
|
|
prtBertPattern INTEGER,
|
|
prtBertInjectRate INTEGER,
|
|
prtBertInjectErrRateCmd INTEGER,
|
|
prtBertInjectSingleErrCmd INTEGER,
|
|
prtBertRunTime Integer32,
|
|
prtBertESs Integer32,
|
|
prtBertSyncLoss Integer32,
|
|
prtBertErrorBits Integer32,
|
|
prtBertClearCounters INTEGER,
|
|
prtBertSyncStatus INTEGER,
|
|
prtBertTs OCTET STRING,
|
|
prtBertResult DisplayString,
|
|
prtBertTxBits Integer32,
|
|
prtBertRxBits Integer32,
|
|
prtBertTxErrorBits Integer32
|
|
}
|
|
|
|
prtBertPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside/external, inside/internal.
|
|
|
|
In the Kilomux, the port index is calculated as follows:
|
|
100*Slot+Ch. The external Ch numbers are 1..10, and the
|
|
internal Ch numbers are 11..20.
|
|
|
|
In the DXC :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
|
|
In the MP :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be according to the external port
|
|
number within the card:
|
|
exPrt1 -> 1
|
|
exPrt2 -> 3
|
|
exPrt3 -> 5
|
|
exPrt4 -> 7 . "
|
|
::= { prtBertEntry 1}
|
|
|
|
prtBertPattern OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
p2E3m1 (1),
|
|
p2E4m1 (2),
|
|
p2E5m1 (3),
|
|
p2E6m1 (4),
|
|
p2E7m1 (5),
|
|
p511 (6),
|
|
p2E10m1 (7),
|
|
p2047 (8),
|
|
p2E15m1 (9),
|
|
p2E17m1 (10),
|
|
p2E18m1 (11),
|
|
p2E20m1 (12),
|
|
qrss (13),
|
|
p2E21m1 (14),
|
|
p2E22m1 (15),
|
|
p2E23m1 (16),
|
|
p2E25m1 (17),
|
|
p2E28m1 (18),
|
|
p2E29m1 (19),
|
|
p2E31m1 (20),
|
|
p2E32m1 (21),
|
|
rj011 (22),
|
|
p63 (23),
|
|
p1M7S (24),
|
|
p1S7M (25),
|
|
alternate(26),
|
|
mark (27),
|
|
space (28),
|
|
p2E11m1 (29),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the pattern of the BERT.
|
|
p2Exxm1 = 2Exx-1.
|
|
pxx = pattern xx.
|
|
This object is the same for all configurations.
|
|
notApplicable - when this object is not supported."
|
|
::= { prtBertEntry 2}
|
|
|
|
prtBertInjectRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noError (1),
|
|
r10Em1 (2),
|
|
r10Em2 (3),
|
|
r10Em3 (4),
|
|
r10Em4 (5),
|
|
r10Em5 (6),
|
|
r10Em6 (7),
|
|
r10Em7 (8),
|
|
single (9),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the error rate injection of the BERT.
|
|
r10Emx = 10E-x
|
|
This object is the same for all configurations.
|
|
single - single error injection.
|
|
notApplicable - when this object is not supported."
|
|
::= { prtBertEntry 3}
|
|
|
|
prtBertInjectErrRateCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object controls activation/deactivation of the Error
|
|
Rate Injection during BERT."
|
|
::= { prtBertEntry 4}
|
|
|
|
prtBertInjectSingleErrCmd OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables to initiate a Single Error Injection
|
|
during BERT (on). Upon completion, the value will
|
|
automatically change to off(2)."
|
|
::= { prtBertEntry 5}
|
|
|
|
prtBertRunTime OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates how much time (seconds) passed since
|
|
BERT started to run."
|
|
::= { prtBertEntry 6}
|
|
|
|
prtBertESs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How many Errored Seconds were detected since BERT started
|
|
to run.
|
|
Counter for Kmux and MP."
|
|
::= { prtBertEntry 7}
|
|
|
|
prtBertSyncLoss OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How many times Sync Loss was detected since BERT started
|
|
to run.
|
|
For some products: number of seconds in which Sync Loss occured
|
|
since BERT started to run. See product specification."
|
|
::= { prtBertEntry 8}
|
|
|
|
prtBertErrorBits OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How many Error Bits were detected since BERT started
|
|
to run."
|
|
::= { prtBertEntry 9}
|
|
|
|
prtBertClearCounters OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object to ON, will enforce a clear
|
|
operation of some BERT Counters. Upon completion,
|
|
the value will automatically change to off(2)."
|
|
::= { prtBertEntry 10}
|
|
|
|
prtBertSyncStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
syncLoss (2),
|
|
sync (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Sync Status while BERT runs."
|
|
::= { prtBertEntry 11}
|
|
|
|
prtBertTs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates on which TSs of the selected port, BERT
|
|
should be applied.
|
|
Each Bit of the Octet represents a TS:
|
|
31 ......0
|
|
MSB LSB
|
|
|
|
Bit 0 will not be used.
|
|
If the bit value is '1' - BERT should be applied on this TS.
|
|
For a T1 port, the valid raised bits ('1') are: 1..25.
|
|
For an E1 port, the valid raised bits ('1') are: 1..31.
|
|
|
|
Agents that do not support this feature will send SIZE 0."
|
|
::= { prtBertEntry 12}
|
|
|
|
prtBertResult OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates Result of BERT
|
|
for the selected port
|
|
(number of error bits divided to the total
|
|
number of data bits.)
|
|
Applicable only if BERT is running on this port
|
|
|
|
Agents that do not support this feature will send SIZE 0."
|
|
::= { prtBertEntry 13}
|
|
|
|
|
|
prtBertTxBits OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How many data bits were transmitted since BERT started
|
|
to run, or since last counter clear
|
|
(prtBertClearCounters set to on)."
|
|
::= { prtBertEntry 14}
|
|
|
|
prtBertRxBits OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"How many data bits were Received since BERT started
|
|
to run, or since last counter clear
|
|
(prtBertClearCounters set to on)."
|
|
::= { prtBertEntry 15}
|
|
|
|
|
|
prtBertTxErrorBits OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Number of injected error bits since BERT started
|
|
to run, or since last counter clear
|
|
(prtBertClearCounters set to on)."
|
|
::= { prtBertEntry 16}
|
|
|
|
|
|
|
|
--Port Monitoring Table - for Monitoring ports
|
|
--The table is applicable only for DXC T1/E1/HS ports and Optimux-T3
|
|
|
|
prtMonTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtMonEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For DXC, the write operation into the Table's Objects is valid only
|
|
for the TmpCnfg entry (Scratch)."
|
|
::= { prtGen 6}
|
|
|
|
prtMonEntry OBJECT-TYPE
|
|
SYNTAX PrtMonEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtMonCnfgIdx, prtMonitoringIdx }
|
|
::= { prtMonTable 1}
|
|
|
|
PrtMonEntry ::=
|
|
SEQUENCE {
|
|
prtMonCnfgIdx Integer32,
|
|
prtMonitoringIdx Integer32,
|
|
prtMonitoringEnable INTEGER,
|
|
prtMonitoringTSs OCTET STRING,
|
|
prtMonitoredPort Integer32,
|
|
prtMonitoredTSs OCTET STRING
|
|
}
|
|
|
|
prtMonCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Idx of the Cnfg(1..255) being
|
|
accessed.
|
|
Idx of 255 relates to the TmpCnfg.
|
|
For products that do not support configurations, 1 will be always used."
|
|
::= { prtMonEntry 1}
|
|
|
|
prtMonitoringIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Monitoring Port Index.
|
|
For DXC:
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: external, internal.
|
|
* The external ports will according to the convention (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The internal ports will be according to the convention (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
For Optimux-T3:
|
|
255 (Not Applicable) will be always used. The Monitoring port is always
|
|
the Station Clock (not considered an interface)."
|
|
::= { prtMonEntry 2}
|
|
|
|
prtMonitoringEnable OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if the prtMonitoringIdx is configured as
|
|
a monitoring port or not.
|
|
disabled = the port is NOT configured to monitor. Setting this object
|
|
to this value will cause reset (to 0) of the prtMonitoringTSs
|
|
and prtMonitoredTSs objects.
|
|
enabled = the port IS configured to monitor.
|
|
For Optimux-T3: always enabled (RO supported)."
|
|
::= {prtMonEntry 3}
|
|
|
|
prtMonitoringTSs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates which TSs of the Monitoring port,
|
|
the test equipment should monitor.
|
|
Each Bit of the Octet represents a TS:
|
|
31 ......0
|
|
MSB LSB
|
|
|
|
Bit 0 will not be used.
|
|
If the bit value is '1' - this TS should be monitored.
|
|
For a T1 port, the valid raised bits ('1') are: 1..24.
|
|
For an E1 port, the valid raised bits ('1') are: 1..31.
|
|
Default: all bits='0'
|
|
Agents that do not support this feature will send SIZE 0.
|
|
This object can be Set as described only if prtMonitoringEnable=enabled. "
|
|
::= {prtMonEntry 4}
|
|
|
|
prtMonitoredPort OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the MONITORED Port Index that the Monitoring
|
|
port monitors.
|
|
For DXC:
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: external, internal.
|
|
* The external ports will according to the convention (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The internal ports will be according to the convention (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
* 100 - no port monitored
|
|
For Optimux-T3:
|
|
The valid channels are:
|
|
0 = no Ch monitored
|
|
1..21 or 1..28 (=CH1..CH21 or CH1..CH28) according to product's
|
|
configuration."
|
|
::= { prtMonEntry 5}
|
|
|
|
prtMonitoredTSs OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE(0..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates which TSs of the Monitored port, should be monitored.
|
|
Each Bit of the Octet represents a TS:
|
|
31 ......0
|
|
MSB LSB
|
|
|
|
Bit 0 will not be used.
|
|
If the bit value is '1' - this TS should be monitored.
|
|
For a T1 port, the valid raised bits ('1') are: 1..24.
|
|
For an E1 port, the valid raised bits ('1') are: 1..31.
|
|
Default: all bits='0'
|
|
Agents that do not support this feature will send SIZE 0.
|
|
This object can be Set as described only if prtMonitoringEnable=enabled."
|
|
::= {prtMonEntry 6}
|
|
|
|
|
|
-- Port Configuration Table
|
|
-- This table is applicable for KMUX, FCD-T1/E1 , FCD-T1L/E1L and FCD-U ports
|
|
|
|
prtCfgParam OBJECT IDENTIFIER ::= {prtGen 7}
|
|
|
|
prtCfgParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtCfgParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
to the TmpCnfg entry.
|
|
KMUX parameters are for the cards: KMBE/New, KVF.6 family."
|
|
::= { prtCfgParam 1}
|
|
|
|
prtCfgParamEntry OBJECT-TYPE
|
|
SYNTAX PrtCfgParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtCfgParamCnfgIdx, prtCfgParamIdx }
|
|
::= { prtCfgParamTable 1}
|
|
|
|
PrtCfgParamEntry ::=
|
|
SEQUENCE {
|
|
prtCfgParamCnfgIdx Integer32,
|
|
prtCfgParamIdx Integer32,
|
|
prtCfgParamSlt INTEGER,
|
|
prtCfgParamOperatedMl INTEGER,
|
|
prtCfgParamMlAtoMlBPrio INTEGER,
|
|
prtCfgParamMlBtoMlAPrio INTEGER,
|
|
prtCfgParamInbandLoopDetection INTEGER,
|
|
prtCfgParamInbandLoopPatternCfg INTEGER,
|
|
prtCfgParamInbandLoopActPattern DisplayString,
|
|
prtCfgParamInbandLoopDeactPattern DisplayString
|
|
}
|
|
|
|
prtCfgParamCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg (1..100) being
|
|
accessed.
|
|
Idx 255 relates to the TmpCnfg."
|
|
::= {prtCfgParamEntry 1}
|
|
|
|
prtCfgParamIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the port (within the card when applicable).
|
|
- For KM-2100: Slot*100+Ch
|
|
external ports: Ch=1..10
|
|
internal ports (sub-channels): Ch=11..20.
|
|
- For FCD-T1/E1(L): MAIN=111, SUB=113, CH1=122, CH2=124.
|
|
- For other devices, see specific device's spec. "
|
|
::= {prtCfgParamEntry 2}
|
|
|
|
prtCfgParamSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
kmxIO1 (107),
|
|
kmxIO2 (108),
|
|
kmxIO3 (109),
|
|
kmxIO4 (110),
|
|
kmxIO5 (111),
|
|
kmxIO6 (112),
|
|
kmxIO7 (113),
|
|
kmxIO8 (114),
|
|
kmxIO9 (115),
|
|
kmxIO10(116),
|
|
kmxIO11(117),
|
|
kmxIO12(118),
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the slot where
|
|
the card is inserted in.
|
|
In the 2104 Unit the entries kmxIO5(111)..kmxIO12(118) are not valid.
|
|
notApplicable(255) - for products that do not have Slots."
|
|
::= {prtCfgParamEntry 3}
|
|
|
|
prtCfgParamOperatedMl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
kmxMlA (103),
|
|
kmxMlB (104)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The main link for this channel.
|
|
The field is relevant only for ML modes of Dual, Priority
|
|
Bumping and Switched Backup."
|
|
::= {prtCfgParamEntry 4}
|
|
|
|
prtCfgParamMlAtoMlBPrio OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
low (2),
|
|
high (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ML-A to ML-B Priority.
|
|
The field is relevant only for ML modes of Priority Bumping
|
|
and Switched Backup."
|
|
::= {prtCfgParamEntry 5}
|
|
|
|
prtCfgParamMlBtoMlAPrio OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
low (2),
|
|
high (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"ML-B to ML-A Priority.
|
|
The field is relevant only for ML modes of Priority Bumping."
|
|
::= {prtCfgParamEntry 6}
|
|
|
|
prtCfgParamInbandLoopDetection OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable(1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inband Loop Detection.
|
|
The field is relevant for FCD-T1/E1(L) ports."
|
|
::= {prtCfgParamEntry 7}
|
|
|
|
prtCfgParamInbandLoopPatternCfg OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
rdlLoop (2),
|
|
userConfig (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if Inband Loop polynomial pattern
|
|
will be according to RDL Loop (the standard) or User Configurated
|
|
according to prtCfgParamInbandLoopActPattern and
|
|
prtCfgParamInbandLoopDeactPattern."
|
|
::= {prtCfgParamEntry 8}
|
|
|
|
prtCfgParamInbandLoopActPattern OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a binary string of up to 8 bits.
|
|
Though the syntax allows for any ASCII characters, for this object
|
|
only '0' or '1' characters are valid.
|
|
The string determines coefficients of the polynomial pattern
|
|
sent to the port in order to Activate the Inband Loop.
|
|
This object is relevant only when prtCfgParamInbandLoopPatternCfg=userConfig."
|
|
::= {prtCfgParamEntry 9}
|
|
|
|
prtCfgParamInbandLoopDeactPattern OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a binary string of up to 8 bits.
|
|
Though the syntax allows for any ASCII characters, for this object
|
|
only '0' or '1' characters are valid.
|
|
The string determines coefficients of the polynomial pattern
|
|
sent to the port in order to Deactivate the Inband Loop.
|
|
This object is relevant only when prtCfgParamInbandLoopPatternCfg=userConfig."
|
|
::= {prtCfgParamEntry 10}
|
|
|
|
|
|
--DACS T1/E1 port specific parameters
|
|
|
|
--DACS T1/E1 port statistics parameters.
|
|
--These parameters are in addition to those of RFC-1406 MIB.
|
|
|
|
prtT1E1StatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtT1E1StatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T1/E1 port statistics table."
|
|
::= { prtT1E1 1}
|
|
|
|
prtT1E1StatEntry OBJECT-TYPE
|
|
SYNTAX PrtT1E1StatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the T1/E1 port statistics table."
|
|
INDEX { prtT1E1SPrtIdx }
|
|
::= { prtT1E1StatTable 1}
|
|
|
|
PrtT1E1StatEntry ::=
|
|
SEQUENCE {
|
|
prtT1E1SPrtIdx Integer32,
|
|
prtT1E1SSlt INTEGER,
|
|
prtT1E1OosCount Gauge32,
|
|
prtT1E1BpvLastMin Gauge32,
|
|
prtT1E1BpvMax Gauge32
|
|
}
|
|
|
|
prtT1E1SPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
The same numbering as for prtGenPrtIdx.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside.
|
|
* The outside ports will be the T1/E1 cards ports.
|
|
The convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 ."
|
|
::= { prtT1E1StatEntry 1}
|
|
|
|
prtT1E1SSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
standAlone (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the slot where
|
|
the card is inserted in.
|
|
When the unit is stand-alone, this object is not applicable
|
|
and 255 will be used."
|
|
::= { prtT1E1StatEntry 2}
|
|
|
|
prtT1E1OosCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only for an E1 active port.
|
|
It provides the number of red alarm events since the last
|
|
count clearing."
|
|
::= { prtT1E1StatEntry 3 }
|
|
|
|
prtT1E1BpvLastMin OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only for an E1 active port.
|
|
It provides the number of BPV (BiPolar Violation) events
|
|
detected during the last minute."
|
|
::= { prtT1E1StatEntry 4 }
|
|
|
|
prtT1E1BpvMax OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only for an E1 active port.
|
|
It provides the maximal number of BPV (BiPolar Violation)
|
|
events (per minute), detected during the worst minute."
|
|
::= { prtT1E1StatEntry 5 }
|
|
|
|
|
|
--DACS T1/E1 port configuration parameters.
|
|
--
|
|
--Objects 2..9 appear in RFC-1406 MIB (dsx1ConfigTable) as RW
|
|
--objects. They were entered in this private MIB, because in
|
|
--RFC-1406 MIB there is no reference to configuration number.
|
|
|
|
|
|
prtT1E1CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtT1E1CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T1/E1 port configuration table."
|
|
::= { prtT1E1 2}
|
|
|
|
prtT1E1CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtT1E1CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the T1/E1 port configuration table."
|
|
INDEX { prtT1E1CnfgIdx, prtT1E1PrtIdx }
|
|
::= { prtT1E1CnfgTable 1}
|
|
|
|
PrtT1E1CnfgEntry ::= SEQUENCE {
|
|
prtT1E1CnfgIdx Integer32,
|
|
prtT1E1PrtIdx Integer32,
|
|
prtT1E1Slt INTEGER,
|
|
prtT1E1LineType INTEGER,
|
|
prtT1E1LineCode INTEGER,
|
|
prtT1E1SignalMode INTEGER,
|
|
prtT1E1Fdl INTEGER,
|
|
prtT1E1FdlMode INTEGER,
|
|
prtT1E1Sync INTEGER,
|
|
prtT1E1CGA INTEGER,
|
|
prtT1E1IdleCode OCTET STRING,
|
|
prtT1E1OosSignal INTEGER,
|
|
prtT1E1VoiceOos OCTET STRING,
|
|
prtT1E1DataOos OCTET STRING,
|
|
prtT1E1LineLengthMask INTEGER,
|
|
prtT1E1TxGainMask INTEGER,
|
|
prtT1E1InbandMng INTEGER,
|
|
prtT1E1InbandMngRate INTEGER,
|
|
prtT1E1DedicatedTs Integer32,
|
|
prtT1E1InbandMngRoutProt INTEGER,
|
|
prtT1E1LinkMode INTEGER,
|
|
prtT1E1Multiplier INTEGER,
|
|
prtT1E1RxGain INTEGER,
|
|
prtT1E1RAI INTEGER,
|
|
prtT1E1LineMode INTEGER,
|
|
prtT1E1TS0SaBits OCTET STRING,
|
|
prtT1E1ConnectedTS INTEGER,
|
|
prtT1E1Ts0SaBit INTEGER,
|
|
prtT1E1SameFeCnfg INTEGER,
|
|
prtT1E1RemCrc4 INTEGER,
|
|
prtT1E1MaxTSs Integer32,
|
|
prtT1E1EocTsConfig INTEGER,
|
|
prtT1E1Role INTEGER,
|
|
prtT1E1PppEchoFailDetection INTEGER,
|
|
prtT1E1CasOosPattern INTEGER,
|
|
prtT1E1CasOosSpaceCode Unsigned32,
|
|
prtT1E1CasOosMarkCode Unsigned32
|
|
}
|
|
|
|
prtT1E1CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config. "
|
|
::= { prtT1E1CnfgEntry 1}
|
|
|
|
prtT1E1PrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
The same numbering as for prtGenPrtIdx.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside.
|
|
In the DXC :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
|
|
In the Kilomux, the port index is calculated as follows:
|
|
100*Slot+Ch. The external Ch numbers are 1..10, and the
|
|
internal Ch numbers are 11..20."
|
|
::= { prtT1E1CnfgEntry 2}
|
|
|
|
prtT1E1Slt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
|
|
kmxMlA (103),
|
|
kmxMlB (104),
|
|
|
|
kmxOpt (106),
|
|
kmxIO1 (107),
|
|
kmxIO2 (108),
|
|
kmxIO3 (109),
|
|
kmxIO4 (110),
|
|
kmxIO5 (111),
|
|
kmxIO6 (112),
|
|
kmxIO7 (113),
|
|
kmxIO8 (114),
|
|
kmxIO9 (115),
|
|
kmxIO10(116),
|
|
kmxIO11(117),
|
|
kmxIO12(118),
|
|
standAlone (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the slot where
|
|
the card is inserted in.
|
|
When the unit is stand-alone, this object is not applicable
|
|
and 255 will be used."
|
|
::= { prtT1E1CnfgEntry 3}
|
|
|
|
prtT1E1LineType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
esf (2),
|
|
d4 (3), --sf
|
|
e1 (4),
|
|
e1Crc (5),
|
|
e1MF (6),
|
|
e1CrcMF (7),
|
|
unframed (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable indicates the variety of T1/E1
|
|
Line implementing this circuit. The type of
|
|
circuit affects the number of bits per second
|
|
that the circuit can reasonably carry, as well
|
|
as the interpretation of the usage and error
|
|
statistics. The values, in sequence, describe:
|
|
|
|
TITLE: SPECIFICATION:
|
|
esf Extended SuperFrame DS1
|
|
d4 AT&T D4 format DS1 - SF
|
|
e1 CCITT Recommendation G.704
|
|
(Table 4a) - G732N
|
|
e1Crc CCITT Recommendation G.704
|
|
(Table 4b) - G732N with CRC
|
|
e1MF G.704 (Table 4a) with TS16
|
|
multiframing enabled - G732S
|
|
e1CrcMF G.704 (Table 4b) with TS16
|
|
multiframing enabled - G732S with CRC
|
|
unframed
|
|
|
|
T1 - applicable values: (1),(2),(3),(8)
|
|
E1 - applicable values: (1),(4),(5),(6),(7),(8) "
|
|
::= { prtT1E1CnfgEntry 4 }
|
|
|
|
prtT1E1LineCode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
jbzs (1),
|
|
b8zs (2),
|
|
hdb3 (3),
|
|
zbtsi(4),
|
|
ami (5),
|
|
other(6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This variable describes the variety of Zero
|
|
Code Suppression used on the link, which in
|
|
turn affects a number of its characteristics.
|
|
|
|
jbzs=b7zs refers the Jammed Bit Zero Suppres-
|
|
sion, in which the AT&T specification of at
|
|
least one pulse every 8 bit periods is literal-
|
|
ly implemented by forcing a pulse in bit 8 of
|
|
each channel. Thus, only seven bits per chan-
|
|
nel, or 1.344 Mbps, is available for data (used for T1).
|
|
|
|
b8zs refers to the use of a specified pattern
|
|
of normal bits and bipolar violations
|
|
which are used to replace a sequence of eight
|
|
zero bits (used for T1).
|
|
|
|
ANSI Clear Channels may use zbtsi, or Zero
|
|
Byte Time Slot Interchange.
|
|
|
|
E1 links, with or without CRC, use hdb3 or
|
|
ami (= TRAN).
|
|
|
|
amI (=TRAN) refers to a mode wherein no zero code
|
|
suppression is present and the line encoding
|
|
does not solve the problem directly. In this
|
|
application, the higher layer must provide data
|
|
which meets or exceeds the pulse density re-
|
|
quirements, such as inverting HDLC data."
|
|
::= { prtT1E1CnfgEntry 5 }
|
|
|
|
prtT1E1SignalMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
robbedBit (2),
|
|
bitOriented (3), --CAS
|
|
messageOriented (4) --CCS
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"'none' indicates that no bits are reserved for
|
|
signaling on this channel.
|
|
|
|
'robbedBit' indicates that T1 Robbed Bit Signaling is in use.
|
|
|
|
'bitOriented' indicates that E1 Channel Associated
|
|
Signaling (CAS) is in use.
|
|
|
|
'messageOriented' indicates that Common Channel Signaling
|
|
(CCS) is in use either on channel 16 of an E1 link or
|
|
channel 24 of a T1."
|
|
::= { prtT1E1CnfgEntry 6 }
|
|
|
|
prtT1E1Fdl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
ansi-T1-403(2),
|
|
att-54016 (4),
|
|
fdl-none (8),
|
|
transFdl (16)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This bitmap describes the use of the facili-
|
|
ties data link, and is the sum of the capabili-
|
|
ties:
|
|
|
|
'other' indicates that a protocol other than
|
|
one following is used.
|
|
|
|
'ansi-T1-403' refers to the FDL exchange
|
|
recommended by ANSI.
|
|
|
|
'att-54016' refers to ESF FDL exchanges.
|
|
|
|
'fdl-none' indicates that the device does
|
|
not use the FDL.
|
|
'transFdl' indicates transition between two ports of
|
|
the same card. "
|
|
::= { prtT1E1CnfgEntry 7 }
|
|
|
|
prtT1E1FdlMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
user (2),
|
|
carrier (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Fdl Mode of the T1 selected port.
|
|
notApplicable - will be used for an E1 port."
|
|
::= { prtT1E1CnfgEntry 8 }
|
|
|
|
|
|
prtT1E1Sync OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
tr62411(2),
|
|
ccitt (3),
|
|
fast (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables returning to normal operation, after
|
|
the end of a main/sub link red alarm event, in reduced time.
|
|
'tr62411' - complies with AT&T TR-62411 (after 10 seconds).
|
|
Applicable for both T1 and E1 interfaces.
|
|
'ccitt' - complies with CCITT standard. Applicable only
|
|
for E1 interfaces.
|
|
'fast' - after 1 second."
|
|
::= { prtT1E1CnfgEntry 9 }
|
|
|
|
prtT1E1CGA OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
none (1),
|
|
trans(2),
|
|
full (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object selects the method used to signal the CGA state
|
|
to the other end, through the main/sub link.
|
|
'none' - non-transparent mode. When one of the links
|
|
(main/sub) will be in Out Of Service state, both
|
|
'Data/Voice Oos' and 'Oos Signal' will be
|
|
transmitted to the other end.
|
|
'trans' - when one of the links (main/sub) will be in Out
|
|
Of Service state, 'Data/Voice Oos' will be
|
|
transmitted to the other end.
|
|
'full' - fully-transparent mode. When one of the links
|
|
(main/sub) will be in Out Of Service state,
|
|
neither 'Data/Voice Oos' nor 'Oos Signal' will
|
|
be transmitted to the other end."
|
|
::= { prtT1E1CnfgEntry 10 }
|
|
|
|
prtT1E1IdleCode OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object selects the code transmitted to fill idle
|
|
(unused) time slots in the main link frame.
|
|
Valid range: (0 - FF HEX) ."
|
|
::= { prtT1E1CnfgEntry 11 }
|
|
|
|
prtT1E1OosSignal OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notsupported (2),
|
|
forcedIdle (3),
|
|
forcedBusy (4),
|
|
busyIdle (5),
|
|
idleBusy (6)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"'idle' = '0' = on-hook, idle state
|
|
'busy' = '1' = off-hook, busy state
|
|
'forcedIdle' = SP = both A and B signaling bits are forced
|
|
to '0' during out-of-service periods.
|
|
'forcedBusy' = MK = both A and B signaling bits are forced
|
|
to '1' during out-of-service periods.
|
|
'busyIdle' = MK_SP = A and B bits are forced to '1' for
|
|
2.5 seconds; then they are switched to '0'
|
|
until out-of-service condition disappears.
|
|
'idleBusy' = SP_MK = A and B bits are forced to '0' for
|
|
2.5 seconds; then they are switched to '1'
|
|
until out-of-service condition disappears.
|
|
- for T1: '0'=0 ; '1'=1
|
|
- for E1: '0'=1 ; '1'=0 "
|
|
::= { prtT1E1CnfgEntry 12 }
|
|
|
|
prtT1E1VoiceOos OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Voice Out-Of-Service code. Valid range: (0 - FF HEX).
|
|
For agents that do not support this feature, the value will
|
|
always be 0."
|
|
::= { prtT1E1CnfgEntry 13 }
|
|
|
|
prtT1E1DataOos OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..4))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Data Out-Of-Service code. Valid range: (0 - FF HEX).
|
|
For agents that do not support this feature, the value will
|
|
always be 0."
|
|
::= { prtT1E1CnfgEntry 14 }
|
|
|
|
prtT1E1LineLengthMask OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
len0p133ft (2),
|
|
len134p266ft (3),
|
|
len267p399ft (4),
|
|
len400p533ft (5),
|
|
len534p655ft (6),
|
|
fcc68 (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the line length mask parameter used only
|
|
for T1/DSU interfaces.
|
|
len400p533ft=length range: 400ft to 533ft
|
|
'fcc68' - provides compliance with the FCC 68.308 Option A
|
|
output pulse mask. "
|
|
::= { prtT1E1CnfgEntry 15 }
|
|
|
|
prtT1E1TxGainMask OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
txGain0db (2),
|
|
txGain7dot5db (3),
|
|
txGain15db (4),
|
|
txGain22dot5db (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the tx gain mask parameter (dB), used
|
|
only for T1/CSU interfaces."
|
|
::= { prtT1E1CnfgEntry 16 }
|
|
|
|
prtT1E1InbandMng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
off (2),
|
|
fdlOrTs0 (3),
|
|
dedicatedTs (4),
|
|
dedicatedPpp(5),
|
|
dedicatedFr (6),
|
|
internal (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify an Inband management over the
|
|
link.
|
|
internal - supported by KM-2100 only. It means that the management is internal
|
|
to the frame. It takes part of the ML Frame bits (instead of data)."
|
|
::= {prtT1E1CnfgEntry 17}
|
|
|
|
prtT1E1InbandMngRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
r4k (2),
|
|
r8k (3),
|
|
r12k (4),
|
|
r16k (5),
|
|
r32k (6),
|
|
r64k (7),
|
|
r20k (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify the rate of the Inband management.
|
|
It is required only for E1 links and is applicable only when
|
|
prtExT1E1InbandMng selected is FdlOrTs0 or dedicatedTs."
|
|
::= {prtT1E1CnfgEntry 18}
|
|
|
|
prtT1E1DedicatedTs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
|
|
"The value is differently determined for different products.
|
|
There are two methods:
|
|
|
|
1) A unique number to identify Dedicated TS of the T1/E1 port.
|
|
It is applicable only when prtExT1E1InbandMng selected is
|
|
dedicatedTs.
|
|
1..24 - Dedicated TS of T1
|
|
1..31 - Dedicated TS of E1
|
|
255 - notApplicable (for agents that do not support this
|
|
feature)
|
|
Other values are invalid.
|
|
|
|
2) For FCD-STM, up to five TSs may be dedicated to management.
|
|
This object value is the Sum (sigma) of 2**n, where n =TS-1
|
|
e.g. Time slots 3,5,7,9,11 are dedicated to management:
|
|
2** 2
|
|
+2** 4
|
|
+2** 6
|
|
+2** 8
|
|
+2**10 = 4+16+64+256+1024=1364
|
|
|
|
User should consult the product specification, to find out
|
|
the method employed."
|
|
::= {prtT1E1CnfgEntry 19}
|
|
|
|
prtT1E1InbandMngRoutProt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
proprietary (3),
|
|
rip2 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Inband Mng Routing Protocol of the port.
|
|
When prtT1E1InbandMng is 'dedicatedPpp'-'proprietary' and
|
|
'rip2' are applicable.
|
|
For other values - only 'proprietary' is applicable.
|
|
|
|
For FCD-M and FCD-A:
|
|
When prtT1E1InbandMng is 'dedicatedPpp' or 'dedicatedFr':
|
|
'None', 'proprietary' and 'rip2' are applicable.
|
|
When prtT1E1InbandMng is 'fdlOrTS0' or 'dedicatedTs':
|
|
'None' and 'proprietary' are applicable.
|
|
When prtT1E1InbandMng is 'off':
|
|
'None' is applicable."
|
|
::= {prtT1E1CnfgEntry 20}
|
|
|
|
prtT1E1LinkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
regular (2),
|
|
transparent (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"regular - TSs are connected by user via TS Assignment only
|
|
transparent - when a port with this Link Mode is connected to an
|
|
internal T1/E1 port of a T3/E3 card, TS0, TS16 and Fbit
|
|
are transparently transferred to the E3/T3 stream."
|
|
::= {prtT1E1CnfgEntry 21}
|
|
|
|
prtT1E1Multiplier OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
br56 (2),
|
|
br64 (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The data rate of each TS. The multiplier values
|
|
can be 56 kbps or 64 kbps. For T1 only."
|
|
::= { prtT1E1CnfgEntry 22 }
|
|
|
|
prtT1E1RxGain OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
rxGain12dB (2),
|
|
rxGain30dB (3),
|
|
rxGain36dB (4),
|
|
shortHaul (5),
|
|
longHaul (6),
|
|
rxGain20dB (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute is the rx volume (dB)."
|
|
::= { prtT1E1CnfgEntry 23 }
|
|
|
|
prtT1E1RAI OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
off (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Remote Alarm Signal"
|
|
::= { prtT1E1CnfgEntry 24 }
|
|
|
|
prtT1E1LineMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
csu (2),
|
|
dsu (3),
|
|
ltu (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Interface type of the port.
|
|
For T1 - csu, dsu are the valid values
|
|
For E1 - dsu, ltu are the valid values"
|
|
::= { prtT1E1CnfgEntry 25 }
|
|
|
|
prtT1E1TS0SaBits OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only for E1 ports. For T1, string size will be 0.
|
|
For E1, it enables user to select the use of TS0 Sa Bits 4..8, by 3 octets:
|
|
The order (in hexa display):
|
|
free Sa-Bit-4 Sa-Bit-5 Sa-Bit-6 Sa-Bit-7 Sa-Bit-8
|
|
|___________| |________________| |________________|
|
|
MSByte LSByte
|
|
|
|
Each Sa Bit will be represented by a nibble, having the following meaning:
|
|
0000 = zero
|
|
0001 = one
|
|
0010 = management
|
|
0011 = transparent
|
|
the rest are reserved for future use."
|
|
::= { prtT1E1CnfgEntry 26 }
|
|
|
|
prtT1E1ConnectedTS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates if there is any connected TS for this interface."
|
|
::= { prtT1E1CnfgEntry 27 }
|
|
|
|
prtT1E1Ts0SaBit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
noMng (2),
|
|
mng (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whether to send TS 0, or not.
|
|
noMng= TS 0 is looped, therefore not sent.
|
|
mng= TS 0 isn't looped, therefore it is sent."
|
|
::= { prtT1E1CnfgEntry 28 }
|
|
|
|
prtT1E1SameFeCnfg OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This parameter indicates whether the same E1 configuration
|
|
parameters and TS assignment are set both to the local
|
|
and remote device.
|
|
Read-Write access is applicable only in G732N framed mode.
|
|
For G732S and UNFRAMED this parameter is set by
|
|
agent to YES and is Read Only.
|
|
In Case of conflict during power-up between the central
|
|
and remote, the value set by the central unit is the valid one."
|
|
::= { prtT1E1CnfgEntry 29 }
|
|
|
|
prtT1E1RemCrc4 OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the E1 of the Remote device
|
|
connected to this E1 port, will have CRC-4 or not."
|
|
::= { prtT1E1CnfgEntry 30 }
|
|
|
|
prtT1E1MaxTSs OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only for DXC D4T1, D4E1, D8T1, D8E1
|
|
external ports and D8GSL internal E1 ports.
|
|
It is relevant only when sysCIntTsAllocMode=static(2).
|
|
255=not applicable
|
|
If prtT1E1LineType=unframed(8), the value of this object must be 32.
|
|
Else, the valid values are 0..31."
|
|
::= { prtT1E1CnfgEntry 31}
|
|
|
|
prtT1E1EocTsConfig OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the use of EOC for TS Configuration
|
|
is enabled or not."
|
|
::= { prtT1E1CnfgEntry 32 }
|
|
|
|
prtT1E1Role OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
sub (2),
|
|
main (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether this port behaves as SUB or Main link."
|
|
::= { prtT1E1CnfgEntry 33 }
|
|
|
|
prtT1E1PppEchoFailDetection OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates whether the PPP Echo is taken into account
|
|
for its Fail Detection.
|
|
This object is relevant when Inband Mng between devices is Dedicated TS PPP.
|
|
Default=Disable.
|
|
Enable - will be selected mainly when a T1/E1 Ring exists and between 2 adjacent
|
|
Ring devices there is another device or Net, that causes these Ring devices
|
|
not to sense that the PPP connection between them is lost. In this case,
|
|
Echo Request should be initiated by the port."
|
|
::= { prtT1E1CnfgEntry 34 }
|
|
|
|
prtT1E1CasOosPattern OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
space (1),
|
|
mark (2),
|
|
spaceMark (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects defines the Cas Out-Of-Service code
|
|
space (1) - see prtT1E1CasOosSpaceCode below
|
|
mark (2) - see prtT1E1CasOosMarkCode below
|
|
spaceMark (3) - transmit 'space' for 2 sec and
|
|
'mark' for 2 sec repeatedly."
|
|
::= { prtT1E1CnfgEntry 36 }
|
|
|
|
prtT1E1CasOosSpaceCode OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects defines the Cas Out-Of-Service code
|
|
The value that will be transmitted when
|
|
prtT1E1CasOosPattern = space (1).
|
|
default = 14."
|
|
::= { prtT1E1CnfgEntry 37 }
|
|
|
|
prtT1E1CasOosMarkCode OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..15)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This objects defines the Cas Out-Of-Service code
|
|
The value that will be transmitted when
|
|
prtT1E1CasOosPattern = mark (2).
|
|
default = 1."
|
|
::= { prtT1E1CnfgEntry 38 }
|
|
|
|
|
|
|
|
--prtT1E1 Last FDL Message Table - Statistics
|
|
|
|
prtT1E1FdlMsgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtT1E1FdlMsgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table is applicable for a T1 interface with 'esf'
|
|
LineType or E1 interface, when CRC is enabled (LineType)."
|
|
::= { prtT1E1 3}
|
|
|
|
prtT1E1FdlMsgEntry OBJECT-TYPE
|
|
SYNTAX PrtT1E1FdlMsgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {prtT1E1FdlMsgPrtIdx, prtT1E1FdlMsgFdlType}
|
|
::= { prtT1E1FdlMsgTable 1}
|
|
|
|
PrtT1E1FdlMsgEntry ::=
|
|
SEQUENCE {
|
|
prtT1E1FdlMsgPrtIdx Integer32,
|
|
prtT1E1FdlMsgFdlType INTEGER,
|
|
prtT1E1FdlMsgSlt INTEGER,
|
|
prtT1E1FdlMsg OCTET STRING
|
|
}
|
|
|
|
prtT1E1FdlMsgPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
The same numbering as for prtGenPrtIdx.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside.
|
|
* The outside ports will be the T1/E1 cards ports.
|
|
The convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 ."
|
|
::= { prtT1E1FdlMsgEntry 1}
|
|
|
|
prtT1E1FdlMsgFdlType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
send (1),
|
|
receive (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Fdl type reference of the Fdl message."
|
|
::= { prtT1E1FdlMsgEntry 2}
|
|
|
|
prtT1E1FdlMsgSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
standAlone (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the slot where
|
|
the card is inserted in.
|
|
When the unit is stand-alone, this object is not applicable
|
|
and 255 will be used."
|
|
::= { prtT1E1FdlMsgEntry 3}
|
|
|
|
prtT1E1FdlMsg OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"FDL message."
|
|
::= { prtT1E1FdlMsgEntry 4}
|
|
|
|
|
|
--prtHS specific parameters (configuration & status) table
|
|
|
|
prtHSParamTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtHSParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { prtHS 1 }
|
|
|
|
prtHSParamEntry OBJECT-TYPE
|
|
SYNTAX PrtHSParamEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtHSCnfgIdx, prtHSPrtIdx }
|
|
::= { prtHSParamTable 1}
|
|
|
|
PrtHSParamEntry ::=
|
|
SEQUENCE {
|
|
prtHSCnfgIdx Integer32,
|
|
prtHSPrtIdx Integer32,
|
|
prtHSSlt INTEGER,
|
|
prtHSRate INTEGER,
|
|
prtHSFifoSize INTEGER,
|
|
prtHSClkMode INTEGER,
|
|
prtHSCTS INTEGER,
|
|
prtHSRtsState INTEGER,
|
|
prtHSInbandLoopback INTEGER,
|
|
prtHSInbandLoopPatternCfg INTEGER,
|
|
prtHSInbandLoopActPattern DisplayString,
|
|
prtHSInbandLoopDeactPattern DisplayString,
|
|
prtHSDCD INTEGER,
|
|
prtHSClkPolarity INTEGER,
|
|
prtHSInterfaceType INTEGER,
|
|
prtHSUnframed INTEGER
|
|
}
|
|
|
|
prtHSCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config. "
|
|
::= { prtHSParamEntry 1}
|
|
|
|
prtHSPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside,
|
|
SP.
|
|
* The inside ports will be the HS cards ports. The
|
|
convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 ."
|
|
::= { prtHSParamEntry 2}
|
|
|
|
prtHSSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
standAlone (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the slot where
|
|
the card is inserted in.
|
|
When the unit is stand-alone, this object is not applicable
|
|
and 255 will be used."
|
|
::= { prtHSParamEntry 3}
|
|
|
|
prtHSRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
r0x56eq0Kbps (1),
|
|
r1x56eq56Kbps (2),
|
|
r2x56eq112Kbps (3),
|
|
r3x56eq168Kbps (4),
|
|
r4x56eq224Kbps (5),
|
|
r5x56eq280Kbps (6),
|
|
r6x56eq336Kbps (7),
|
|
r7x56eq392Kbps (8),
|
|
r8x56eq448Kbps (9),
|
|
r9x56eq504Kbps (10),
|
|
r10x56eq560Kbps (11),
|
|
r11x56eq616Kbps (12),
|
|
r12x56eq672Kbps (13),
|
|
r13x56eq728Kbps (14),
|
|
r14x56eq784Kbps (15),
|
|
r15x56eq840Kbps (16),
|
|
r16x56eq896Kbps (17),
|
|
r17x56eq952Kbps (18),
|
|
r18x56eq1008Kbps(19),
|
|
r19x56eq1064Kbps(20),
|
|
r20x56eq1120Kbps(21),
|
|
r21x56eq1176Kbps(22),
|
|
r22x56eq1232Kbps(23),
|
|
r23x56eq1288Kbps(24),
|
|
r24x56eq1344Kbps(25),
|
|
r25x56eq1400Kbps(26),
|
|
r26x56eq1456Kbps(27),
|
|
r27x56eq1512Kbps(28),
|
|
r28x56eq1568Kbps(29),
|
|
r29x56eq1624Kbps(30),
|
|
r30x56eq1680Kbps(31),
|
|
r31x56eq1736Kbps(32),
|
|
r0x64eq0Kbps (33),
|
|
r1x64eq64Kbps (34),
|
|
r2x64eq128Kbps (35),
|
|
r3x64eq192Kbps (36),
|
|
r4x64eq256Kbps (37),
|
|
r5x64eq320Kbps (38),
|
|
r6x64eq384Kbps (39),
|
|
r7x64eq448Kbps (40),
|
|
r8x64eq512Kbps (41),
|
|
r9x64eq576Kbps (42),
|
|
r10x64eq640Kbps (43),
|
|
r11x64eq704Kbps (44),
|
|
r12x64eq768Kbps (45),
|
|
r13x64eq832Kbps (46),
|
|
r14x64eq896Kbps (47),
|
|
r15x64eq960Kbps (48),
|
|
r16x64eq1024Kbps(49),
|
|
r17x64eq1088Kbps(50),
|
|
r18x64eq1152Kbps(51),
|
|
r19x64eq1216Kbps(52),
|
|
r20x64eq1280Kbps(53),
|
|
r21x64eq1344Kbps(54),
|
|
r22x64eq1408Kbps(55),
|
|
r23x64eq1472Kbps(56),
|
|
r24x64eq1536Kbps(57),
|
|
r25x64eq1600Kbps(58),
|
|
r26x64eq1664Kbps(59),
|
|
r27x64eq1728Kbps(60),
|
|
r28x64eq1792Kbps(61),
|
|
r29x64eq1856Kbps(62),
|
|
r30x64eq1920Kbps(63),
|
|
r31x64eq1984Kbps(64),
|
|
r32x64eq2048Kbps(65),
|
|
|
|
r32x56eq1792Kbps(66),
|
|
r64x64eq4096Kbps(67),
|
|
|
|
auto (200)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port rate (speed).
|
|
auto - rate is selected automatically by system."
|
|
::= { prtHSParamEntry 4}
|
|
|
|
prtHSFifoSize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
auto (1),
|
|
b32bit (2),
|
|
b60bit (3),
|
|
b104bit (4),
|
|
b144bit (5),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object selects the size of the user data channel buffer
|
|
FIFO used in the DTE2 mode. In the other modes, buffer
|
|
size is automatically set by the DACS agent.
|
|
Buffer FIFO size in bits, corresponds to FIFO lengths of
|
|
+/-16, +/-30, +/-52, +/-72 bits."
|
|
::= { prtHSParamEntry 5}
|
|
|
|
prtHSClkMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dce (1),
|
|
dte1 (2),
|
|
dte2 (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock Mode of the user data channel.
|
|
dce - DACS operates as a DCE and provides transmit
|
|
and receive clocks to the synchronous user DTE.
|
|
dte1- DACS supplies the receive clock to the user
|
|
equipment and accepts the user transmit clock.
|
|
dte2- DACS requires transmit and receive clocks from
|
|
the user equipment."
|
|
::= { prtHSParamEntry 6}
|
|
|
|
prtHSCTS OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
on (1),
|
|
rts (2),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selection of CTS line state in the user data channel.
|
|
on - CTS continuously ON.
|
|
rts - CTS line follows the RTS line."
|
|
::= { prtHSParamEntry 7}
|
|
|
|
prtHSRtsState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off (2),
|
|
on (3),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"RTS state of the port."
|
|
::= { prtHSParamEntry 8}
|
|
|
|
prtHSInbandLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disabled (2),
|
|
enabled (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if Inband Loopback from the Network
|
|
should be enabled or disabled."
|
|
::= {prtHSParamEntry 9}
|
|
|
|
prtHSInbandLoopPatternCfg OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
rdlLoop (2),
|
|
userConfig (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates if Inband Loop polynomial pattern
|
|
will be according to RDL Loop (the standard) or User Configurated
|
|
according to prtHSActivatePolyPattern and prtHSDeactivatePolyPattern."
|
|
::= {prtHSParamEntry 10}
|
|
|
|
prtHSInbandLoopActPattern OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a binary string of up to 8 bits.
|
|
Though the syntax allows for any ASCII characters, for this object
|
|
only '0' or '1' characters are valid.
|
|
The string determines coefficients of the polynomial pattern
|
|
sent to the port in order to Activate the Inband Loop.
|
|
This object is relevant only when prtHSInbandLoopPatternCfg=userConfig."
|
|
::= {prtHSParamEntry 11}
|
|
|
|
prtHSInbandLoopDeactPattern OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a binary string of up to 8 bits.
|
|
Though the syntax allows for any ASCII characters, for this object
|
|
only '0' or '1' characters are valid.
|
|
The string determines coefficients of the polynomial pattern
|
|
sent to the port in order to Deactivate the Inband Loop.
|
|
This object is relevant only when prtHSInbandLoopPatternCfg=userConfig."
|
|
::= {prtHSParamEntry 12}
|
|
|
|
prtHSDCD OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
linkOK (2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Selection of DCD line state in the user data channel.
|
|
linkOK - DCD line is ON only when active link is OK.
|
|
on - DCD continuously ON."
|
|
::= { prtHSParamEntry 13}
|
|
|
|
prtHSClkPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
normal (2),
|
|
invert (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the clock polarity."
|
|
::= {prtHSParamEntry 14}
|
|
|
|
prtHSInterfaceType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
rs530 (2), --EIA 530
|
|
v35 (3),
|
|
rs422 (4),
|
|
x21 (5),
|
|
v24 (6),
|
|
rs530a (7), --EIA 530A
|
|
rs232 (8),
|
|
rs449 (9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the selected electrical interface type."
|
|
::= {prtHSParamEntry 15}
|
|
|
|
prtHSUnframed OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Unframed line for HS ports.
|
|
yes - means that all TSs must be transferred, including TS0.
|
|
In this case, prtHSRate must be r31x56eq1736Kbps OR
|
|
r31x64eq1984Kbps."
|
|
::= { prtHSParamEntry 16}
|
|
|
|
|
|
|
|
prtHSBertTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtHSBertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { prtHS 2 }
|
|
|
|
prtHSBertEntry OBJECT-TYPE
|
|
SYNTAX PrtHSBertEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtHSBertPrtIdx }
|
|
::= { prtHSBertTable 1}
|
|
|
|
PrtHSBertEntry ::=
|
|
SEQUENCE {
|
|
prtHSBertPrtIdx Integer32,
|
|
prtHSBertSlt INTEGER,
|
|
prtHSBertCountClr INTEGER,
|
|
prtHSBertTestResult Integer32
|
|
}
|
|
|
|
prtHSBertPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside,
|
|
SP.
|
|
* The inside ports will be the HS cards ports. The
|
|
convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 ."
|
|
::= { prtHSBertEntry 1}
|
|
|
|
prtHSBertSlt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
standAlone (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the slot where
|
|
the card is inserted in.
|
|
When the unit is stand-alone, this object is not applicable
|
|
and 255 will be used."
|
|
::= { prtHSBertEntry 2}
|
|
|
|
|
|
prtHSBertCountClr OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
off(2),
|
|
on (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Setting this object (to on) initiate bert counter clear
|
|
operation.
|
|
Valid only when bert test is active on the specific port.
|
|
(Every time a new bert test starts, the counter is
|
|
automatically cleared; this command enables clearing
|
|
the counter while the test is running)."
|
|
::= { prtHSBertEntry 3}
|
|
|
|
prtHSBertTestResult OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the number of Bit Error Rate indicated
|
|
during the BERT test.
|
|
Active only when bert test is running on the selected port."
|
|
::= { prtHSBertEntry 4}
|
|
|
|
|
|
|
|
--prt SP specific configuration parameters
|
|
|
|
prtSpCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtSpCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {prtSP 1}
|
|
|
|
prtSpCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtSpCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"All the entries at this table are identical(have the same value)
|
|
at all the configurations(1..255) except at the TmpCnfg.
|
|
- For products supporting more than one configuration, the write operation
|
|
into the Table Objects is valid only at the TmpCnfg entry.
|
|
- For products that do not support configurations, the write operation
|
|
into the Table Objects will be to prtSpCnfgIdx=1."
|
|
INDEX {prtSpCnfgIdx, prtSpPrtIdx }
|
|
::= { prtSpCnfgTable 1}
|
|
|
|
PrtSpCnfgEntry ::= SEQUENCE {
|
|
prtSpCnfgIdx Integer32,
|
|
prtSpPrtIdx Integer32,
|
|
prtSpUsage INTEGER,
|
|
prtSpRate INTEGER,
|
|
prtSpDataBits INTEGER,
|
|
prtSpParity INTEGER,
|
|
prtSpCallOutMode INTEGER,
|
|
prtSpInterface INTEGER,
|
|
prtSpCTS INTEGER,
|
|
prtSpDcdDelay INTEGER,
|
|
prtSpDsr INTEGER,
|
|
prtSpNoOfRetries Integer32,
|
|
prtSpWaitForConnect INTEGER,
|
|
prtSpDialMode INTEGER,
|
|
prtSpAltNumMode INTEGER,
|
|
prtSpPrimaryNum DisplayString,
|
|
prtSpAltNum DisplayString,
|
|
prtSpRoutProtocol INTEGER,
|
|
prtSpCmd OCTET STRING,
|
|
prtSpActCallOut INTEGER,
|
|
prtSpAlrRelayMode INTEGER,
|
|
prtSpStopBits INTEGER
|
|
}
|
|
|
|
|
|
prtSpCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..255) being
|
|
accessed.
|
|
Idx of 255 relates to the TmpCnfg."
|
|
::= { prtSpCnfgEntry 1}
|
|
|
|
prtSpPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number of the SPor DP port.
|
|
For DXC, it is the port in the active DCL card:
|
|
- SP = 1
|
|
- NP ; DP = 2
|
|
|
|
For Kilomux, the port index is calculated as follows:
|
|
100*Slot+Ch.
|
|
|
|
For FCD, PRBi, the SP port index=1.
|
|
For Optimux-T3, the SP port index=71."
|
|
::= { prtSpCnfgEntry 2}
|
|
|
|
prtSpUsage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown (1),
|
|
noUse (2),
|
|
nmsSlip (3),
|
|
nmsPpp (4),
|
|
muxSlip (5),
|
|
muxPpp (6),
|
|
terminal(7),
|
|
dialOut (8)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates what is the usage of the port."
|
|
::= { prtSpCnfgEntry 3}
|
|
|
|
prtSpRate OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
auto (1),
|
|
s300bps (2),
|
|
s1200bps (3),
|
|
s2400bps (4),
|
|
s4800bps (5),
|
|
s9600bps (6),
|
|
s19200bps (7),
|
|
s38400bps (8),
|
|
s57600bps (9),
|
|
s115200bps(10)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the operation rate (speed) of the port.
|
|
auto - automatic rate selection, by the agent."
|
|
::= { prtSpCnfgEntry 4}
|
|
|
|
prtSpDataBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dataBits7 (1),
|
|
dataBits8 (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the number of data bits in async
|
|
frame"
|
|
::= { prtSpCnfgEntry 5}
|
|
|
|
prtSpParity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
none (1),
|
|
odd (2),
|
|
even (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the parity mode in async frame"
|
|
::= { prtSpCnfgEntry 6}
|
|
|
|
prtSpCallOutMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
all (3),
|
|
major (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the call-out mode.
|
|
For DXC - this object is applicable only for the DP port (2)."
|
|
::= { prtSpCnfgEntry 7}
|
|
|
|
|
|
prtSpInterface OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
dce (1),
|
|
dte (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the supervisory port interface.
|
|
dce - the DACS appears as a DCE for the port.
|
|
dte - the DACS operates as a DTE, for connection via modem,
|
|
for the port."
|
|
::= { prtSpCnfgEntry 8}
|
|
|
|
prtSpCTS OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
on (2),
|
|
rts (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"CTS line state. This object is applicable only for
|
|
port (1) = SP"
|
|
::= { prtSpCnfgEntry 9}
|
|
|
|
prtSpDcdDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
d0 (2),
|
|
d10 (3),
|
|
d50 (4),
|
|
d100 (5),
|
|
d200 (6),
|
|
d300 (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DCD delay in msec.
|
|
d10 = delay of 10msec.
|
|
This object is applicable only for port (1) = SP"
|
|
::= { prtSpCnfgEntry 10}
|
|
|
|
prtSpDsr OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
on (2),
|
|
dtr (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DSR line state. This object is applicable only for
|
|
port (1) = SP"
|
|
::= { prtSpCnfgEntry 11}
|
|
|
|
prtSpNoOfRetries OBJECT-TYPE
|
|
SYNTAX Integer32 (0..8)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For DXC - this object is applicable only for port (2) = DP.
|
|
The number of dialing retries requested.
|
|
Default = 0"
|
|
::= { prtSpCnfgEntry 12}
|
|
|
|
prtSpWaitForConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
t30sec (2),
|
|
t45sec (3),
|
|
t60sec (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For DXC - this object is applicable only for port (2) = DP.
|
|
Waiting time for connect, in seconds.
|
|
Default = 30 sec."
|
|
::= { prtSpCnfgEntry 13}
|
|
|
|
prtSpDialMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
tone (2),
|
|
pulse (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For DXC - this object is applicable only for port (2) = DP.
|
|
Dialing mode.
|
|
Default=tone"
|
|
::= { prtSpCnfgEntry 14}
|
|
|
|
prtSpAltNumMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For DXC - this object is applicable only for port (2) = DP.
|
|
It determines wether to use the alternate number or not.
|
|
Default = no."
|
|
::= { prtSpCnfgEntry 15}
|
|
|
|
prtSpPrimaryNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For DXC - this object is applicable only for port (2) = DP.
|
|
It is the Primary dialing number. "
|
|
::= { prtSpCnfgEntry 16}
|
|
|
|
prtSpAltNum OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"For DXC - this object is applicable only for port (2) = DP.
|
|
It is the Alternate dialing number. This number
|
|
is applicable only if prtSpAltNumMode is 'yes'."
|
|
::= { prtSpCnfgEntry 17}
|
|
|
|
prtSpRoutProtocol OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
proprietary (3),
|
|
rip2 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the routing protocol of the port.
|
|
notApplicable - for DP."
|
|
::= { prtSpCnfgEntry 18}
|
|
|
|
prtSpCmd OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (20))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SP Command.
|
|
For LRS this parameter will be used for a Modem Command.
|
|
Upon NMS's Get operation for devices that this parameter
|
|
is notApplicable, agent will send NULL string."
|
|
::= { prtSpCnfgEntry 19}
|
|
|
|
prtSpActCallOut OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
always (2),
|
|
linkFail (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates when to Activate Call-Out.
|
|
It is used by FCD-T1/E1.
|
|
always - to activate call-out always.
|
|
linkFail - to activate call-out only when Link of Inband Management fails."
|
|
::= { prtSpCnfgEntry 20}
|
|
|
|
|
|
prtSpAlrRelayMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
normal (2),
|
|
invert (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Alarm Relay Mode.
|
|
notApplicable - for DP."
|
|
::= { prtSpCnfgEntry 21}
|
|
|
|
|
|
prtSpStopBits OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
stopBits1 (2),
|
|
stopBits1dot5 (3),
|
|
stopBits2 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates number of stop bits in an async frame."
|
|
::= { prtSpCnfgEntry 22}
|
|
|
|
|
|
|
|
|
|
|
|
--prt DIM (DXC Inverse Multiplexer) specific parameters
|
|
|
|
prtDimCnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtDimCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {prtDim 1}
|
|
|
|
prtDimCnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtDimCnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation into the Table Objects is valid only
|
|
for the TmpCnfg entry (prtDimCnfgIdx=255)."
|
|
INDEX {prtDimCnfgIdx, prtDimIdx }
|
|
::= { prtDimCnfgTable 1}
|
|
|
|
PrtDimCnfgEntry ::=
|
|
SEQUENCE {
|
|
prtDimCnfgIdx Integer32,
|
|
prtDimIdx Integer32,
|
|
prtDimTxMode INTEGER,
|
|
prtDimPolarity INTEGER,
|
|
prtDimClkMode INTEGER,
|
|
prtDimMaxDelay INTEGER,
|
|
prtDimMng INTEGER,
|
|
prtDimMngRoutProt INTEGER
|
|
}
|
|
|
|
|
|
prtDimCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..255) being
|
|
accessed.
|
|
Idx of 255 relates to the TmpCnfg."
|
|
::= { prtDimCnfgEntry 1}
|
|
|
|
prtDimIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number of the
|
|
DIM card.
|
|
The convention used for DXC:
|
|
(IO slot number+10)*10 + 1
|
|
Example: port1 of IO slot 11 will be: 211 ."
|
|
::= { prtDimCnfgEntry 2}
|
|
|
|
|
|
prtDimTxMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
regularTx (2),
|
|
broadcast (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tx mode.
|
|
regularTx - the links are connected to a similar outfit on
|
|
the other side. In this mode, if a link fails,
|
|
the transmitted bandwidth is decreased
|
|
accordingly.
|
|
broadcast - the links are connected to MORE than one similar
|
|
outfit on the other side. In this mode, if a link
|
|
fails, the transmitted bandwidth is not affected "
|
|
::= { prtDimCnfgEntry 3}
|
|
|
|
prtDimPolarity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
normalClk (2),
|
|
inverted (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Polarity."
|
|
::= { prtDimCnfgEntry 4}
|
|
|
|
prtDimClkMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
extDce (2),
|
|
dce (3),
|
|
smooth (4),
|
|
extSmooth(5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Clock Mode.
|
|
smooth - a clock that is not 'pulsed'(has no 'gaps'). In this mode
|
|
the DXC does NOT receive back the clock signal.
|
|
extSmooth - same as 'smooth' but in this mode, the DXC receives back
|
|
the clock signal."
|
|
::= { prtDimCnfgEntry 5}
|
|
|
|
prtDimMaxDelay OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
t16msec (2),
|
|
t64msec (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Max Delay permitted between the links, in msec."
|
|
::= { prtDimCnfgEntry 6}
|
|
|
|
prtDimMng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
disabled (2), --none
|
|
ts1 (3), --dedicated
|
|
dedicatedFr(4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Use of DIM port for management.
|
|
disabled - no management on DIM
|
|
ts1 - 1 bit of TS1 is used for management."
|
|
::= { prtDimCnfgEntry 7}
|
|
|
|
prtDimMngRoutProt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
proprietary (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Mng Routing Protocol of the port.
|
|
none - when prtDimMng is 'disabled'."
|
|
::= { prtDimCnfgEntry 8}
|
|
|
|
|
|
prtDimDestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtDimDestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= {prtDim 2}
|
|
|
|
prtDimDestEntry OBJECT-TYPE
|
|
SYNTAX PrtDimDestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The write operation is valid only for the TmpCnfg entry
|
|
(prtDimDestCnfgIdx=255)."
|
|
INDEX {prtDestCnfgIdx, prtDestDimIdx, prtDestIdx }
|
|
::= { prtDimDestTable 1}
|
|
|
|
PrtDimDestEntry ::=
|
|
SEQUENCE {
|
|
prtDestCnfgIdx Integer32,
|
|
prtDestDimIdx Integer32,
|
|
prtDestIdx Integer32,
|
|
prtDest Integer32,
|
|
prtDestConnect INTEGER
|
|
}
|
|
|
|
|
|
prtDestCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Cnfg(1..255) being
|
|
accessed.
|
|
Idx of 255 relates to the TmpCnfg."
|
|
::= { prtDimDestEntry 1}
|
|
|
|
prtDestDimIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number of the
|
|
DIM card.
|
|
The convention used for DXC:
|
|
(IO slot number+10) & 1
|
|
Example: port1 of IO slot 11 will be: 211 ."
|
|
::= { prtDimDestEntry 2}
|
|
|
|
prtDestIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..8)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a destination number of the
|
|
DIM card. "
|
|
::= { prtDimDestEntry 3}
|
|
|
|
|
|
prtDest OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Destination port,(of a T1/E1 port), that is connected to the
|
|
DIM card, for the specified Destination number.
|
|
0 = No destination port.
|
|
Else:
|
|
For external ports:
|
|
(IO Slot+10) & 1 for port 1
|
|
(IO Slot+10) & 3 for port 2
|
|
Example: port2 of IO slot 12 will be: 223 .
|
|
For internal ports :
|
|
(IO Slot+10) & 2 for port 1
|
|
(IO Slot+10) & 4 for port 2
|
|
(IO Slot+10) & 6 for port 3
|
|
(IO Slot+10) & 8 for port 4, etc..."
|
|
::= { prtDimDestEntry 4}
|
|
|
|
prtDestConnect OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
no (2),
|
|
yes(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Connection Status of the specified destination number.
|
|
For a specified destination port, it depends both on the
|
|
status of the port and on the status of the far-end port.
|
|
Since this is a RO object, same value will be received for
|
|
all configurations."
|
|
::= { prtDimDestEntry 5}
|
|
|
|
|
|
--prtI - ISDN specific parameters table
|
|
|
|
prtICnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtICnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { prtI 1 }
|
|
|
|
prtICnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtICnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtICnfgIdx, prtIIdx }
|
|
::= { prtICnfgTable 1}
|
|
|
|
PrtICnfgEntry ::=
|
|
SEQUENCE {
|
|
prtICnfgIdx Integer32,
|
|
prtIIdx Integer32,
|
|
prtIRate INTEGER,
|
|
prtIConnect INTEGER
|
|
}
|
|
|
|
|
|
prtICnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config. "
|
|
::= {prtICnfgEntry 1}
|
|
|
|
prtIIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside,
|
|
SP.
|
|
* The ISDN B1, B2, D channels will be inside ports.
|
|
For port index, see product specification."
|
|
::= {prtICnfgEntry 2}
|
|
|
|
prtIRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
nc (2),
|
|
r2bit (3),
|
|
r4bit (4),
|
|
r8bit (5)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the port rate in bits.
|
|
Each TS contains 8 bits. Thus, 1 bit is equivalent to 8Kbps
|
|
rate."
|
|
::= {prtICnfgEntry 3}
|
|
|
|
prtIConnect OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
no (2),
|
|
yes (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"D channel connection.
|
|
no - disconnected
|
|
yes - connected. "
|
|
::= {prtICnfgEntry 4}
|
|
|
|
|
|
--prtHdsl - HDSL specific parameters table
|
|
|
|
prtHdslTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtHdslEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "HDSL port table."
|
|
::= { prtHdsl 1 }
|
|
|
|
prtHdslEntry OBJECT-TYPE
|
|
SYNTAX PrtHdslEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { prtHdslIdx }
|
|
::= { prtHdslTable 1}
|
|
|
|
PrtHdslEntry ::=
|
|
SEQUENCE {
|
|
prtHdslIdx Integer32,
|
|
prtHdslMode INTEGER,
|
|
prtHdslRptrType INTEGER,
|
|
prtHdslMaxRate INTEGER,
|
|
prtHdslLinkType INTEGER,
|
|
prtHdslCompSwVer DisplayString,
|
|
prtHdslCompHwVer DisplayString
|
|
}
|
|
|
|
prtHdslIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify a port.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside.
|
|
* The HDSL ports will be external.
|
|
For port index, see product specification."
|
|
::= {prtHdslEntry 1}
|
|
|
|
prtHdslMode OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
central (2),
|
|
remote (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the HDSL mode."
|
|
::= {prtHdslEntry 2}
|
|
|
|
prtHdslRptrType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
none (2),
|
|
hrpt (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Repeater between Near and Far modem.
|
|
none - no repeater exists between the modems
|
|
hrpt - HRPT repeater exists between the modems."
|
|
::= {prtHdslEntry 3}
|
|
|
|
prtHdslMaxRate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
r192 (2),
|
|
r256 (3),
|
|
r320 (4),
|
|
r384 (5),
|
|
r448 (6),
|
|
r512 (7),
|
|
r576 (8),
|
|
r640 (9),
|
|
r768 (10),
|
|
r896 (11),
|
|
r1024 (12),
|
|
r1152 (13),
|
|
r1280 (14),
|
|
r1536 (15),
|
|
r1920 (16),
|
|
r2048 (17)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Maximum Rate of the xDSL Line, in Kbps units.
|
|
This object can be Set only for a Central unit."
|
|
::= {prtHdslEntry 4}
|
|
|
|
prtHdslLinkType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (1),
|
|
msdsl2w (2),
|
|
hdsl2w (3),
|
|
hdsl4w (4),
|
|
gDsl (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Link Type.
|
|
msdsl2w - MSDSL 2 Wire
|
|
hdsl2w - HDSL 2 Wire
|
|
hdsl4w - HDSL 4 Wire
|
|
gDsl - G.DSL "
|
|
::= {prtHdslEntry 5}
|
|
|
|
prtHdslCompSwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Software Version of the
|
|
component (Piggyback card) supporting this interface."
|
|
::= {prtHdslEntry 6}
|
|
|
|
prtHdslCompHwVer OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Hardware Version of the
|
|
component (Piggyback card) supporting this interface."
|
|
::= {prtHdslEntry 7}
|
|
|
|
|
|
--DACS T3/E3 port configuration parameters. Applicable also for Optimux-T3 Links.
|
|
--
|
|
--These objects were entered in this private MIB, because they do not
|
|
--appear in RFC1407 (except prtT3E3LineLength which appears in meters) and in
|
|
--RFC-1407 MIB there is no reference to configuration number.
|
|
|
|
|
|
prtT3E3CnfgTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PrtT3E3CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"T3/E3 port configuration table."
|
|
::= { prtT3E3 1}
|
|
|
|
prtT3E3CnfgEntry OBJECT-TYPE
|
|
SYNTAX PrtT3E3CnfgEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
" An entry in the T3/E3 port configuration table."
|
|
INDEX { prtT3E3CnfgIdx, prtT3E3PrtIdx }
|
|
::= { prtT3E3CnfgTable 1}
|
|
|
|
PrtT3E3CnfgEntry ::=
|
|
SEQUENCE {
|
|
prtT3E3CnfgIdx
|
|
Integer32,
|
|
prtT3E3PrtIdx
|
|
Integer32,
|
|
prtT3E3Slt
|
|
INTEGER,
|
|
prtT3E3LineLength
|
|
INTEGER,
|
|
prtT3E3InbandMng
|
|
INTEGER,
|
|
prtT3E3AisFrame
|
|
INTEGER,
|
|
prtT3E3TxClockSource
|
|
INTEGER,
|
|
prtT3E3RoutProt
|
|
INTEGER,
|
|
prtT3E3AisTransmit
|
|
INTEGER
|
|
}
|
|
|
|
prtT3E3CnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32 (1..255)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the Idx of the Config being accessed.
|
|
Idx of 255 relates to the Temporary (Scratch) Config.
|
|
For DXC, write operations can be performed only on the Temp Config.
|
|
For products that do not support configurations, always 1 will be used."
|
|
::= { prtT3E3CnfgEntry 1}
|
|
|
|
prtT3E3PrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
For DXC:
|
|
The same numbering as for prtGenPrtIdx.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside.
|
|
* The external ports convention used will be (for DXC):
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
For Optimux-T3:
|
|
Link-A: 51
|
|
Link-B: 61 . "
|
|
::= { prtT3E3CnfgEntry 2}
|
|
|
|
prtT3E3Slt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
standAlone (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number to identify the slot where
|
|
the card is inserted in.
|
|
When the unit is stand-alone, this object is not applicable
|
|
and 255 will be used."
|
|
::= { prtT3E3CnfgEntry 3}
|
|
|
|
prtT3E3LineLength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
len0p450ft (2),
|
|
len451p900ft (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the length of the ds3 line in feet.
|
|
It provides information for line build out circuitry if it exists
|
|
and can use this object to adjust the line build out.
|
|
len0p450ft = 0 - 450 feet
|
|
len451p900ft = 451 - 900 feet."
|
|
::= { prtT3E3CnfgEntry 4}
|
|
|
|
prtT3E3InbandMng OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
off (2),
|
|
cBit (3), --Cbit-Tx-Rx
|
|
cBitTxRxMng (4),
|
|
cBitTx (5),
|
|
cBitTxMng (6),
|
|
m13 (7),
|
|
cdpv (8),
|
|
nationalBit (9)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique number to identify the Frame Type over the link.
|
|
For Optimux-T3: only values (4), (7) are supported."
|
|
::= {prtT3E3CnfgEntry 5}
|
|
|
|
prtT3E3AisFrame OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
unframed (2),
|
|
framed (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is applicable only for Optimux-T3.
|
|
It allows user to select whether the AIS sent will be framed or unframed."
|
|
::= { prtT3E3CnfgEntry 6}
|
|
|
|
prtT3E3TxClockSource OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
external(1), -- loopTiming
|
|
internal(2), -- localTiming
|
|
notApplicable(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Tx Clock Source."
|
|
::= { prtT3E3CnfgEntry 7}
|
|
|
|
prtT3E3RoutProt OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
none (2),
|
|
proprietary (3),
|
|
rip2 (4)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Routing Protocol of the port.
|
|
This object is applicable only for T3 ports."
|
|
::= { prtT3E3CnfgEntry 8}
|
|
|
|
prtT3E3AisTransmit OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
disable (2),
|
|
enable (3)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if AIS signal will be transmitted over the tributary E3/DS3
|
|
upon failure."
|
|
::= { prtT3E3CnfgEntry 9}
|
|
|
|
|
|
--DACS General data, unrelated to a specific level or unit type
|
|
|
|
--Compressed data table - applicable for all the MIB leafs,
|
|
--Used only by NMS station
|
|
|
|
cmprTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF CmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { genDacsMux 1 }
|
|
|
|
cmprEntry OBJECT-TYPE
|
|
SYNTAX CmprEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {cmprTypeIdx, cmprCnfgIdx,cmprVersion,cmprSltIdx,cmprPrtIdx}
|
|
::= {cmprTable 1}
|
|
|
|
CmprEntry ::=
|
|
SEQUENCE {
|
|
cmprTypeIdx Integer32,
|
|
cmprCnfgIdx Integer32,
|
|
cmprVersion Integer32,
|
|
cmprSltIdx INTEGER,
|
|
cmprPrtIdx Integer32,
|
|
cmprObj OCTET STRING
|
|
}
|
|
|
|
cmprTypeIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the Type of the Compressed
|
|
data referred (which table, which level, etc).
|
|
The type is a code according to a convention between
|
|
agent and NMS."
|
|
::= { cmprEntry 1}
|
|
|
|
cmprCnfgIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the configuration number the
|
|
Compressed information relates to."
|
|
::= { cmprEntry 2}
|
|
|
|
cmprVersion OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates the version of the internal format of
|
|
the Compressed data (the version of the convention used)."
|
|
::= { cmprEntry 3}
|
|
|
|
cmprSltIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
psA (1),
|
|
psB (2),
|
|
clA (3),
|
|
clB (4),
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
notApplicable (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique number of the slot
|
|
position where the card is inserted.
|
|
When the unit is stand-alone or this object is not applicable,
|
|
255 will be used."
|
|
::= { cmprEntry 4}
|
|
|
|
|
|
cmprPrtIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object indicates a unique identifier of the port,
|
|
the compressed information relates to.
|
|
For DXC - according to the order in the card of cmprSltIdx:
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 .
|
|
For FCD: see product's specification.
|
|
If the port number is irrelevant to this parameter (if it is
|
|
a system/card level alarm) the value will be 9999."
|
|
::= { cmprEntry 5}
|
|
|
|
cmprObj OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is the compressed information itself,
|
|
according to a predefined format, both agent and NMS agreed
|
|
about."
|
|
::= { cmprEntry 6}
|
|
|
|
|
|
--mapLinkTable
|
|
|
|
mapLinkTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF MapLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { genDacsMux 2}
|
|
|
|
mapLinkEntry OBJECT-TYPE
|
|
SYNTAX MapLinkEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX {mapLinkIdx}
|
|
::= {mapLinkTable 1}
|
|
|
|
MapLinkEntry ::=
|
|
SEQUENCE {
|
|
mapLinkIdx Integer32,
|
|
mapLinkSlotIdx INTEGER,
|
|
mapLinkPortIdx Integer32,
|
|
mapLinkState INTEGER
|
|
}
|
|
|
|
mapLinkIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A unique identifier of the link"
|
|
::= {mapLinkEntry 1}
|
|
|
|
mapLinkSlotIdx OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
io1 (5),
|
|
io2 (6),
|
|
io3 (7),
|
|
io4 (8),
|
|
io5 (9),
|
|
io6 (10),
|
|
io7 (11),
|
|
io8 (12),
|
|
io9 (13),
|
|
io10 (14),
|
|
io11 (15),
|
|
io12 (16),
|
|
io13 (17),
|
|
io14 (18),
|
|
io15 (19),
|
|
standAlone (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique slot position where
|
|
the module is inserted."
|
|
::= {mapLinkEntry 2}
|
|
|
|
mapLinkPortIdx OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates a unique port number.
|
|
The valid port number depends on the IO slot no., the
|
|
installed card type and the port type: outside, inside,
|
|
SP.
|
|
In the DXC :
|
|
- first two digits will be: (IO slot number+10)
|
|
- last one/two digits will be the port number within the
|
|
card in odd or even numbers, as follows:
|
|
* For the outside/external ports, in odd numbers:
|
|
port1 = 1
|
|
port2 = 3
|
|
port3 = 5
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 213 .
|
|
* The inside/internal ports, in even numbers:
|
|
port1 = 2
|
|
port2 = 4
|
|
port3 = 6
|
|
etc...
|
|
Example: port2 of IO slot 11 will be: 214 ."
|
|
::= {mapLinkEntry 3}
|
|
|
|
mapLinkState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
unknown(1),
|
|
down(2),
|
|
up(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This attribute indicates the status of the link between
|
|
the two muxes"
|
|
::= {mapLinkEntry 4}
|
|
|
|
|
|
--Alarms List -
|
|
--
|
|
--
|
|
|
|
alrGenTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF AlrGenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "A table."
|
|
::= { genDacsMux 3 }
|
|
|
|
alrGenEntry OBJECT-TYPE
|
|
SYNTAX AlrGenEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "An entry in table."
|
|
INDEX { alrGenCode }
|
|
::= { alrGenTable 1}
|
|
|
|
AlrGenEntry ::=
|
|
SEQUENCE {
|
|
alrGenCode Integer32,
|
|
alrGenDescription DisplayString,
|
|
alrGenLevel INTEGER,
|
|
alrGenSlotType INTEGER,
|
|
alrGenSeverity INTEGER,
|
|
alrGenDebounce Integer32,
|
|
alrGenDefSeverity INTEGER
|
|
}
|
|
|
|
alrGenCode OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object is a unique code number, identifying
|
|
a certain alarm."
|
|
::= { alrGenEntry 1}
|
|
|
|
alrGenDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This entry is a unique text description, of the alarm
|
|
corresponding to the specified code."
|
|
::= { alrGenEntry 2}
|
|
|
|
alrGenLevel OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
system (2),
|
|
card (3),
|
|
port (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm level."
|
|
::= {alrGenEntry 3}
|
|
|
|
alrGenSlotType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable(1),
|
|
ps (2),
|
|
cl (3),
|
|
io (4),
|
|
clAndIo (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Slot type that the alarm is relevant to.
|
|
clAndIo - an alarm that is relevant for both CL and IO slots."
|
|
::= {alrGenEntry 4}
|
|
|
|
alrGenSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object enables the user to select a severity for each alarm.
|
|
The severity is set per alarm code (same for all slots/ports
|
|
using this code)."
|
|
::= {alrGenEntry 5}
|
|
|
|
alrGenDebounce OBJECT-TYPE
|
|
SYNTAX Integer32 (0..255)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Debounce time for each alarm code, in seconds.
|
|
The meaning is, that an alarm will be 'declared' as ON (or OFF), only
|
|
after it was actually ON/OFF the Debouncing time selected by user.
|
|
0 = default debounce selection (each alarm has a default value).
|
|
250 = maximum value of seconds for debounce.
|
|
253 = mask = the alarm will Never be reported.
|
|
254 = default debounce selection (each alarm has a default value).
|
|
255 = not applicable "
|
|
::= {alrGenEntry 6}
|
|
|
|
alrGenDefSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notApplicable (1),
|
|
event (3),
|
|
minor (4),
|
|
major (5),
|
|
warning (6),
|
|
critical (7)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object reports the default severity of each alarm.
|
|
User can change the severity of the alarms defined by
|
|
this default via the alrGenSeverity object."
|
|
::= {alrGenEntry 7}
|
|
|
|
------------------------------------------
|
|
-- Card/ Module Common Trap Definitions
|
|
--------------------------------------------
|
|
|
|
|
|
cardEvents OBJECT IDENTIFIER ::= {mdlGen 0}
|
|
|
|
|
|
--CARD HW FAILURE
|
|
cardHwFailure NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType, mdlCHardwareFailureReason }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates HW failure in card indicated by mdlCActualCardType
|
|
"
|
|
::= { cardEvents 1 }
|
|
|
|
--CARD MISMATCH
|
|
cardMismatch NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType, mdlCProgCardType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates that Card indicated by mdlCProgCardType
|
|
is incompatible with active DB
|
|
"
|
|
::= { cardEvents 2 }
|
|
|
|
--CARD PROVISION FAILURE
|
|
cardProvisionFailure NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Provisioning failure of card indicated by
|
|
mdlCActualCardType due to reason indicated by alarmEventReason
|
|
"
|
|
::= { cardEvents 3 }
|
|
|
|
--CARD UNSUPPORTED SW
|
|
cardUnsupportedSw NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType, entPhysicalSoftwareRev }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates that Module software is not supported
|
|
"
|
|
::= { cardEvents 4 }
|
|
|
|
|
|
--CARD UNSUPPORTED HW
|
|
cardUnsupportedHw NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType, entPhysicalHardwareRev }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates that Module hardware is not supported
|
|
"
|
|
::= { cardEvents 5 }
|
|
|
|
--CARD IMPROPER REMOVAL
|
|
cardImproperRemoval NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCProgCardType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Improper card removal
|
|
"
|
|
::= { cardEvents 6 }
|
|
|
|
--CARD NO RESPONSE
|
|
|
|
cardNoResponse NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCProgCardType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Loss of communication with card
|
|
"
|
|
::= { cardEvents 8 }
|
|
|
|
|
|
--CARD INIT FAILURE
|
|
cardInitFailure NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates that Software download to card indiacted by
|
|
mdlCActualCardType failed
|
|
"
|
|
::= { cardEvents 9 }
|
|
|
|
--CARD RESET
|
|
cardReset NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates Card (mdlCActualCardType) Reset
|
|
"
|
|
::= { cardEvents 10 }
|
|
|
|
--CARD PLUGGED IN
|
|
cardPluggedIn NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates that card (indicated by mdlCActualCardType) was
|
|
inserted to slot
|
|
"
|
|
::= { cardEvents 11 }
|
|
|
|
--CARD PLUGGED OUT
|
|
|
|
cardPluggedOut NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCProgCardType }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates that card (indicated by mdlCProgCardType )
|
|
was removed from slot
|
|
"
|
|
::= { cardEvents 12 }
|
|
|
|
--CARD CONFIGURATION MISMATCH
|
|
cardConfigurationMismatch NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlCActualCardType, mdlCConfigMismatchReason }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap indicates a mismatch in the card configuration."
|
|
::= { cardEvents 14 }
|
|
|
|
|
|
dacsMuxEvents OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The events for DACS MUX."
|
|
::= { dacsMux 0 }
|
|
|
|
sanityCheckTrap NOTIFICATION-TYPE
|
|
OBJECTS { sysSSanityCheckStatus, sysDbaseDownloadCnfgIdxCmd }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent after a data base download attempt.
|
|
It returns the sanity result status and the configuration
|
|
no.checked."
|
|
::= { dacsMuxEvents 1 }
|
|
|
|
dacsMuxAlarmsTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when an alarm occurs."
|
|
::= { dacsMuxEvents 2 }
|
|
|
|
mdlConnectTrap NOTIFICATION-TYPE
|
|
OBJECTS {mdlSCardType, mdlSActivity}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when a card is removed."
|
|
::= { dacsMuxEvents 3 }
|
|
|
|
sysAlrStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { sysSAlrStatusAll, sysSAlrStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon any change in the value of any of
|
|
the variables."
|
|
::= { dacsMuxEvents 4 }
|
|
|
|
|
|
sysStatusChangedTrap NOTIFICATION-TYPE
|
|
OBJECTS {agnLed}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent when Leds status is changed."
|
|
::= { dacsMuxEvents 5 }
|
|
|
|
|
|
cnfgUpdateTrap NOTIFICATION-TYPE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This trap is sent upon change of the active Configuration DB."
|
|
::= { dacsMuxEvents 6 }
|
|
|
|
|
|
sysRedundancyStatusTrap NOTIFICATION-TYPE
|
|
OBJECTS { sysDclRedundancyStatus }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent upon change in Redundancy Status."
|
|
::= { dacsMuxEvents 7 }
|
|
|
|
sysRedundancyActiveCardTrap NOTIFICATION-TYPE
|
|
OBJECTS { sysDclOnline }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent upon change of Active Main/CL Card."
|
|
::= { dacsMuxEvents 8 }
|
|
|
|
sysRedundancyActivePortTrap NOTIFICATION-TYPE
|
|
OBJECTS { sysCRdnOnline }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The trap is sent upon change of Active Port of Redundancy Group."
|
|
::= { dacsMuxEvents 9 }
|
|
|
|
|
|
powerDeliveryFailure NOTIFICATION-TYPE
|
|
OBJECTS { alarmEventLogSourceName, alarmEventLogAlarmOrEventId, alarmEventLogDescription,
|
|
alarmEventLogSeverity, alarmEventLogDateAndTime, alarmEventReason,
|
|
entPhysicalAlias, mdlPsTestResult }
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This Trap indicates that a power supply failure exists in the device."
|
|
::= { systemsEvents 73}
|
|
|
|
|
|
|
|