Observium_CE/mibs/rad/ACE2002-MIB

21932 lines
705 KiB
Plaintext

--
-- file :a2002nv3.pkb
--
ACE2002-MIB
DEFINITIONS ::= BEGIN
--Title: ACE2002 MIB
-- Copyright 2201 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.
-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
IMPORTS
TimeTicks,enterprises,
IpAddress, OBJECT-TYPE, Integer32,
Counter32, Gauge32, OBJECT-IDENTITY,
NOTIFICATION-TYPE, Counter64,Unsigned32 FROM SNMPv2-SMI
PerfCurrentCount,
PerfIntervalCount, PerfTotalCount FROM PerfHist-TC-MIB
InterfaceIndex, ifAlias, ifIndex FROM IF-MIB
dsx1LineStatus,
dsx1LineStatusLastChange,
dsx1CurrentIndex, dsx1LineIndex,
dsx1IntervalIndex, dsx1IntervalNumber,
dsx1LoopbackStatus,
dsx1TotalIndex FROM DS1-MIB
imaGroupIndex, imaLinkIfIndex,
imaGroupFailureStatus FROM IMA-MIB
RowStatus, DisplayString, TimeStamp,
DateAndTime, TruthValue FROM SNMPv2-TC
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
frAtmIwfConnectionEntry FROM FR-ATM-PVC-SERVICE-IWF-MIB
isdnSignalingEntry FROM ISDN-MIB
VlanIndex, PortList FROM Q-BRIDGE-MIB
dot1dBasePortEntry FROM BRIDGE-MIB
atmfCESConfEntry FROM ATMF-CES
atmVclEntry, aal5VccEntry,
aal5VccVpi, aal5VccVci,
atmVplVpi, atmVclVpi, atmVclVci,
atmVpCrossConnectEntry,
atmVcCrossConnectEntry,
atmVclEntry, aal5VccEntry FROM ATM-MIB
IANAifType FROM IANAifType-MIB
ipoaLisIfMappingEntry FROM IPOA-MIB ;
-- Some MIB compilers need those two lines:
-- enterprises OBJECT IDENTIFIER ::=
-- { iso org(3) dod(6) internet(1) private(4) 1 }
MacAddress ::= OCTET STRING (SIZE(6))
rad OBJECT IDENTIFIER ::= { enterprises 164 }
radTokenRing OBJECT IDENTIFIER ::= { rad 1 } -- RAD Token Ring tree
radFddi OBJECT IDENTIFIER ::= { rad 2 } -- rad FDDI Tree
radWan OBJECT IDENTIFIER ::= { rad 3 } -- rad WAN Tree
radBridges OBJECT IDENTIFIER ::= {rad 4 }
radConverters OBJECT IDENTIFIER ::= { rad 5 } -- RAD Converters products' tree
radGen OBJECT IDENTIFIER ::= { rad 6} -- General information
radStkHub OBJECT IDENTIFIER ::= { rad 7 } -- stackable products
radAtm OBJECT IDENTIFIER ::= { rad 12} -- stackable products
wanGen OBJECT IDENTIFIER ::= {radWan 1}
diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}
--atmNte OBJECT IDENTIFIER ::= { radAtm 3 }
--atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 }
--atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 }
--dacsMux OBJECT IDENTIFIER ::= {radWan 3}
--genDacsMux OBJECT IDENTIFIER ::= {dacsMux 4}
radRouter OBJECT IDENTIFIER ::= { rad 11 }
rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
radExperimental OBJECT IDENTIFIER ::= { rad 20 } -- Drafts that have no MIB tree yet
-- igmpStdMIB MODULE-IDENTITY ::= { radExperimental 1 }
-- apsMIB OBJECT IDENTIFIER ::= { radExperimental 2 }
--
-- file :v:\doc\rdv\mib\ver495\radgen.txt
--
--Version: 5.00
--First Version Date: 25.01.99
--By: Orly Nicklass
--File: radgen.txt
--Last update: 09-Oct-2003 by Smadar Tauber
systems OBJECT IDENTIFIER ::= { radGen 1} -- list of RAD products
--agnt OBJECT IDENTIFIER ::= { radGen 2} agent general tree
--services OBJECT IDENTIFIER ::= { radGen 3} See services.txt
radSysTR OBJECT IDENTIFIER ::= { systems 1 } -- RAD Token Ring
radRADring OBJECT IDENTIFIER ::= { radSysTR 1 }
radTMA OBJECT IDENTIFIER ::= { radSysTR 2 }
radRingMonitor OBJECT IDENTIFIER ::= { radSysTR 3 }
radSysFddi OBJECT IDENTIFIER ::= { systems 2 } -- RAD Fddi
radFDX100 OBJECT IDENTIFIER ::= { radSysFddi 1 } -- RAD Fddi
radSysWan OBJECT IDENTIFIER ::= { systems 3 } -- RAD Wan products
radSysWanEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Wan products."
::= { radSysWan 0 }
radMP2100 OBJECT IDENTIFIER ::= { radSysWan 1 }
radMP2104 OBJECT IDENTIFIER ::= { radSysWan 2 }
radMP2100B OBJECT IDENTIFIER ::= { radSysWan 3 }
radMP2100F OBJECT IDENTIFIER ::= { radSysWan 4 }
radMP2100H OBJECT IDENTIFIER ::= { radSysWan 5 }
radMP2104H OBJECT IDENTIFIER ::= { radSysWan 6 }
radMP2200B OBJECT IDENTIFIER ::= { radSysWan 7 }
radMP2200F OBJECT IDENTIFIER ::= { radSysWan 8 }
radMX3000 OBJECT IDENTIFIER ::= { radSysWan 9 }
radMX3004 OBJECT IDENTIFIER ::= { radSysWan 10 }
radMX30 OBJECT IDENTIFIER ::= { radSysWan 11 }
radMX300 OBJECT IDENTIFIER ::= { radSysWan 12 }
radVOIP OBJECT IDENTIFIER ::= { radSysWan 13 }
radKM2100 OBJECT IDENTIFIER ::= { radSysWan 15 }
radKM2104 OBJECT IDENTIFIER ::= { radSysWan 16 }
radDXC30 OBJECT IDENTIFIER ::= { radSysWan 20 }
radDXC10A OBJECT IDENTIFIER ::= { radSysWan 21 }
radDXC8R OBJECT IDENTIFIER ::= { radSysWan 22 }
radDXC30E OBJECT IDENTIFIER ::= { radSysWan 23 }
radDXC3000 OBJECT IDENTIFIER ::= { radSysWan 24 }
radDXC8RNew OBJECT IDENTIFIER ::= { radSysWan 25 }
radFcdT1L OBJECT IDENTIFIER ::= { radSysWan 28 }
radFcdE1L OBJECT IDENTIFIER ::= { radSysWan 29 }
radFcdT1 OBJECT IDENTIFIER ::= { radSysWan 30 }
radFcdE1 OBJECT IDENTIFIER ::= { radSysWan 31 }
radFcdE1I OBJECT IDENTIFIER ::= { radSysWan 32 }
radFcdT1M OBJECT IDENTIFIER ::= { radSysWan 33 }
radFcdE1M OBJECT IDENTIFIER ::= { radSysWan 34 }
radFcdIP OBJECT IDENTIFIER ::= { radSysWan 35}
radFcdT1A OBJECT IDENTIFIER ::= { radSysWan 36 }
radFcdE1A OBJECT IDENTIFIER ::= { radSysWan 37 }
radFcdW OBJECT IDENTIFIER ::= { radSysWan 38 }
radFcdSTM OBJECT IDENTIFIER ::= { radSysWan 39 }
radHtuE1Sa OBJECT IDENTIFIER ::= { radSysWan 40 }
radHtuE1 OBJECT IDENTIFIER ::= { radSysWan 41 } --card
radHtu2Sa OBJECT IDENTIFIER ::= { radSysWan 42 }
radHtu2 OBJECT IDENTIFIER ::= { radSysWan 43 } --card
radAsmi450R768Sa OBJECT IDENTIFIER ::= { radSysWan 44 }
radAsmi450R768 OBJECT IDENTIFIER ::= { radSysWan 45 } --card
radAsmi450R1152Sa OBJECT IDENTIFIER ::= { radSysWan 46 }
radAsmi450R1152 OBJECT IDENTIFIER ::= { radSysWan 47 } --card
radLrs12F OBJECT IDENTIFIER ::= { radSysWan 48 }
radLrs12B OBJECT IDENTIFIER ::= { radSysWan 49 }
radLrs52 OBJECT IDENTIFIER ::= { radSysWan 50 }
radHcdE1Sa OBJECT IDENTIFIER ::= { radSysWan 51 }
radHcdE1 OBJECT IDENTIFIER ::= { radSysWan 52 } --card
radHtuT1Sa OBJECT IDENTIFIER ::= { radSysWan 53 }
radHtuT1 OBJECT IDENTIFIER ::= { radSysWan 54 } --card
radOptimux4E1 OBJECT IDENTIFIER ::= { radSysWan 55 }
radOptimux4T1 OBJECT IDENTIFIER ::= { radSysWan 56 }
radOptimuxXLE1 OBJECT IDENTIFIER ::= { radSysWan 57 }
radOptimuxXLT1 OBJECT IDENTIFIER ::= { radSysWan 58 }
radOptimuxXL16E1 OBJECT IDENTIFIER ::= { radSysWan 59 }
radImx64 OBJECT IDENTIFIER ::= { radSysWan 60 }
radImx6L OBJECT IDENTIFIER ::= { radSysWan 61 }
radImx2 OBJECT IDENTIFIER ::= { radSysWan 62 }
radImx4T1 OBJECT IDENTIFIER ::= { radSysWan 63 }
radImx4E1 OBJECT IDENTIFIER ::= { radSysWan 64 }
radImx2T1E1 OBJECT IDENTIFIER ::= { radSysWan 65 }
radImxi4 OBJECT IDENTIFIER ::= { radSysWan 66 }
radOptimux155 OBJECT IDENTIFIER ::= { radSysWan 67 } --SA
radOptimux4T1L OBJECT IDENTIFIER ::= { radSysWan 68 } --SA Low Cost
radOptimux4E1L OBJECT IDENTIFIER ::= { radSysWan 69 } --SA Low Cost
radHtuE1SaV2 OBJECT IDENTIFIER ::= { radSysWan 70 }
radHtuE1V2 OBJECT IDENTIFIER ::= { radSysWan 71 } --card
radFomiE3 OBJECT IDENTIFIER ::= { radSysWan 72 } --card
radFomiT3 OBJECT IDENTIFIER ::= { radSysWan 73 } --card
radOpt4E1C OBJECT IDENTIFIER ::= { radSysWan 74 } --card
radOpt4T1C OBJECT IDENTIFIER ::= { radSysWan 75 } --card
radPrbiE3 OBJECT IDENTIFIER ::= { radSysWan 76 } --SA
radPrbiT3 OBJECT IDENTIFIER ::= { radSysWan 77 } --SA
radHcd4Sa OBJECT IDENTIFIER ::= { radSysWan 78 } --SA
radOptimuxT3 OBJECT IDENTIFIER ::= { radSysWan 79 } --SA
radFRmon OBJECT IDENTIFIER ::= { radSysWan 80 }
radIpMux4 OBJECT IDENTIFIER ::= { radSysWan 81 }
radIpMux1 OBJECT IDENTIFIER ::= { radSysWan 82 }
radIpMux16 OBJECT IDENTIFIER ::= { radSysWan 83 }
radIpMux1E OBJECT IDENTIFIER ::= { radSysWan 84 }
radVmux2100 OBJECT IDENTIFIER ::= { radSysWan 85 }
radMP104 OBJECT IDENTIFIER ::= { radSysWan 86 }
radMP204 OBJECT IDENTIFIER ::= { radSysWan 87 }
radVmux110 OBJECT IDENTIFIER ::= { radSysWan 88 }
-- reserved for radVmux105 OBJECT IDENTIFIER ::= { radSysWan 89 }
radFcd155 OBJECT IDENTIFIER ::= { radSysWan 90 } --SA
radIpMux8 OBJECT IDENTIFIER ::= { radSysWan 91 }
radOptimux155DS3 OBJECT IDENTIFIER ::= { radSysWan 92 } --SA
radOptimuxT3L OBJECT IDENTIFIER ::= { radSysWan 93 } --SA Low Cost
-- reserved for radIpMux1000 OBJECT IDENTIFIER ::= { radSysWan 94 }
radOp16E1L OBJECT IDENTIFIER ::= { radSysWan 95 } --19 inch box
radOp16E1LS OBJECT IDENTIFIER ::= { radSysWan 96 } --half 19 inch box (single)
radPRBm20 OBJECT IDENTIFIER ::= { radSysWan 97 } -- half 19 inch box
radPRBm22 OBJECT IDENTIFIER ::= { radSysWan 98 } -- 19 inch box
-- reserved for radAsmi52Sa OBJECT IDENTIFIER ::= { radSysWan 99 }
radOpXLE1 OBJECT IDENTIFIER ::= { radSysWan 100 } -- New-Look
radOpXLT1 OBJECT IDENTIFIER ::= { radSysWan 101 } -- New-Look
radOpXL16E1 OBJECT IDENTIFIER ::= { radSysWan 102 } -- New-Look
radSysBRG OBJECT IDENTIFIER ::= { systems 4 } -- RAD Bridges products
radTRE1 OBJECT IDENTIFIER ::= { radSysBRG 1 } -- RAD Bridges products
radTRE1D OBJECT IDENTIFIER ::= { radSysBRG 2 } -- RAD Bridges products
radTRE8 OBJECT IDENTIFIER ::= { radSysBRG 3 } -- RAD Bridges products
radTRE8D OBJECT IDENTIFIER ::= { radSysBRG 4 } -- RAD Bridges products
radMBE1 OBJECT IDENTIFIER ::= { radSysBRG 5 } -- RAD Bridges products
radMBE1D OBJECT IDENTIFIER ::= { radSysBRG 6 } -- RAD Bridges products
radMBE8 OBJECT IDENTIFIER ::= { radSysBRG 7 } -- RAD Bridges products
radMBE8D OBJECT IDENTIFIER ::= { radSysBRG 8 } -- RAD Bridges products
radMLBT OBJECT IDENTIFIER ::= { radSysBRG 9 } -- RAD Bridges products
radFEB4DAS OBJECT IDENTIFIER ::= { radSysBRG 10 } -- RAD Bridges products
radTrimBrg10 OBJECT IDENTIFIER ::= { radSysBRG 11 } -- RAD Bridges products
radTrimBrg16 OBJECT IDENTIFIER ::= { radSysBRG 12 } -- RAD Bridges products
radRRTRE8 OBJECT IDENTIFIER ::= { radSysBRG 13 } -- RAD Bridges products
radRRTRE8D OBJECT IDENTIFIER ::= { radSysBRG 14 } -- RAD Bridges products
radRRMLBT OBJECT IDENTIFIER ::= { radSysBRG 15 } -- RAD Bridges products
radRRMLBTF OBJECT IDENTIFIER ::= { radSysBRG 16 } -- RAD Bridges products
radRRTRE1D OBJECT IDENTIFIER ::= { radSysBRG 17 } -- RAD Bridges products
radTRERAS OBJECT IDENTIFIER ::= { radSysBRG 18 } -- RAD Bridges products
radTRERASa OBJECT IDENTIFIER ::= { radSysBRG 19 } -- RAD Bridges products
radMBERAS OBJECT IDENTIFIER ::= { radSysBRG 20 } -- RAD Bridges products
radMBERASa OBJECT IDENTIFIER ::= { radSysBRG 21 } -- RAD Bridges products
radFEB4FDX OBJECT IDENTIFIER ::= { radSysBRG 22 } -- RAD Bridges products
radFEB4SAS OBJECT IDENTIFIER ::= { radSysBRG 23 } -- RAD Bridges products
radRRFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 24 } -- RAD Bridges products
radRRFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 25 } -- RAD Bridges products
radFTBDAS OBJECT IDENTIFIER ::= { radSysBRG 26 } -- RAD Bridges products
radFTBSAS OBJECT IDENTIFIER ::= { radSysBRG 27 } -- RAD Bridges products
radFastWay100 OBJECT IDENTIFIER ::= { radSysBRG 28 } -- RAD Bridges products
radSysCnvrtr OBJECT IDENTIFIER ::= { systems 5 } -- RAD Converters products
radSTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 1 } -- RAD Converters products
radSTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 3 } -- RAD Converters products
radSTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 4 } -- RAD Converters products
radSTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 6 } -- RAD Converters products
radFTC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 10 } -- RAD Converters products
radFTC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 12 } -- RAD Converters products
radFTC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 13 } -- RAD Converters products
radFTC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 15 } -- RAD Converters products
radSEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 20 } -- RAD Converters products
radSEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 22 } -- RAD Converters products
radSEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 23 } -- RAD Converters products
radSEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 25 } -- RAD Converters products
radFEC1 OBJECT IDENTIFIER ::= { radSysCnvrtr 30 } -- RAD Converters products
radFEC2 OBJECT IDENTIFIER ::= { radSysCnvrtr 32 } -- RAD Converters products
radFEC1UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 33 } -- RAD Converters products
radFEC2UDP OBJECT IDENTIFIER ::= { radSysCnvrtr 35 } -- RAD Converters products
radRIC155 OBJECT IDENTIFIER ::= { radSysCnvrtr 36 } -- RAD Converters products
radSysStkHub OBJECT IDENTIFIER ::= { systems 7 } -- RAD Stackable products
radRBHE OBJECT IDENTIFIER ::= { radSysStkHub 1 } -- RAD Stackable products
radRBHT OBJECT IDENTIFIER ::= { radSysStkHub 2 } -- RAD Stackable products
radRBHEEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Stackable products."
::= { radRBHE 0 }
radRBHTEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Stackable products."
::= { radRBHT 0 }
radETS4fddiDAS OBJECT IDENTIFIER ::= { radSysStkHub 3 } -- RAD Stackable products
radETS4fddiSAS OBJECT IDENTIFIER ::= { radSysStkHub 4 } -- RAD Stackable products
radSAHEMX OBJECT IDENTIFIER ::= { radSysStkHub 5 } -- RAD Stackable products
radSAHTM OBJECT IDENTIFIER ::= { radSysStkHub 6 } -- RAD Stackable products
radETS4 OBJECT IDENTIFIER ::= { radSysStkHub 7 } -- RAD Stackable products
radSAHEMU OBJECT IDENTIFIER ::= { radSysStkHub 8 } -- RAD Stackable products
unknown OBJECT IDENTIFIER ::= { radSysStkHub 9 } -- RAD Stackable products
radSAH16Eint OBJECT IDENTIFIER ::= { radSysStkHub 10 } -- RAD Stackable products
radSAH16Tint OBJECT IDENTIFIER ::= { radSysStkHub 11 } -- RAD Stackable products
radSAH16Eext OBJECT IDENTIFIER ::= { radSysStkHub 12 } -- RAD Stackable products
radSAH16Text OBJECT IDENTIFIER ::= { radSysStkHub 13 } -- RAD Stackable products
radSysPS OBJECT IDENTIFIER ::= { systems 8 } -- RAD Packet Switch (PS) products
radSysPSEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Packet Switch (PS) products."
::= { radSysPS 0 }
radSPS2 OBJECT IDENTIFIER ::= { radSysPS 1 } -- RAD Packet Switch (PS) products
radSPS3 OBJECT IDENTIFIER ::= { radSysPS 2 } -- RAD Packet Switch (PS) products
radSPS6 OBJECT IDENTIFIER ::= { radSysPS 3 } -- RAD Packet Switch (PS) products
radSPS9 OBJECT IDENTIFIER ::= { radSysPS 4 } -- RAD Packet Switch (PS) products
radSPS12 OBJECT IDENTIFIER ::= { radSysPS 5 } -- RAD Packet Switch (PS) products
radAPD2 OBJECT IDENTIFIER ::= { radSysPS 6 } -- RAD Packet Switch (PS) products
radAPD8 OBJECT IDENTIFIER ::= { radSysPS 7 } -- RAD Packet Switch (PS) products
radAPS8 OBJECT IDENTIFIER ::= { radSysPS 8 } -- RAD Packet Switch (PS) products
radAPS16 OBJECT IDENTIFIER ::= { radSysPS 9 } -- RAD Packet Switch (PS) products
radAPS24 OBJECT IDENTIFIER ::= { radSysPS 10 } -- RAD Packet Switch (PS) products
radSPS3S OBJECT IDENTIFIER ::= { radSysPS 11} -- RAD Packet Switch (PS) products
radFPS8 OBJECT IDENTIFIER ::= { radSysPS 12} -- RAD Packet Switch (PS) products
radFPS12 OBJECT IDENTIFIER ::= { radSysPS 13} -- RAD Packet Switch (PS) products
radSPS3ScSL OBJECT IDENTIFIER ::= { radSysPS 14} -- RAD Packet Switch (PS) products
radSPS3Sc2S OBJECT IDENTIFIER ::= { radSysPS 15} -- RAD Packet Switch (PS) products
radFPS8c OBJECT IDENTIFIER ::= { radSysPS 16} -- RAD Packet Switch (PS) products
radFPS4 OBJECT IDENTIFIER ::= { radSysPS 17} -- RAD Packet Switch (PS) products
radSysEth OBJECT IDENTIFIER ::= { systems 9 } -- RAD Ethernet products
radEP8T OBJECT IDENTIFIER ::= {radSysEth 1} -- RAD Ethernet products
radEP4TAUI OBJECT IDENTIFIER ::= {radSysEth 2} -- RAD Ethernet products
radEP4T2FL OBJECT IDENTIFIER ::= {radSysEth 3} -- RAD Ethernet products
radEP4TFL OBJECT IDENTIFIER ::= {radSysEth 4} -- RAD Ethernet products
radEP4FL OBJECT IDENTIFIER ::= {radSysEth 5} -- RAD Ethernet products
radEPR8T OBJECT IDENTIFIER ::= {radSysEth 7} -- RAD Ethernet products
radEPR4TAUI OBJECT IDENTIFIER ::= {radSysEth 8} -- RAD Ethernet products
radEPR4T2FL OBJECT IDENTIFIER ::= {radSysEth 9} -- RAD Ethernet products
radEPR4TFL OBJECT IDENTIFIER ::= {radSysEth 10} -- RAD Ethernet products
radEPR4FL OBJECT IDENTIFIER ::= {radSysEth 11} -- RAD Ethernet products
radSysRtr OBJECT IDENTIFIER ::= { systems 11 } -- RAD Router products
radSysRtrEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD Router products."
::= { radSysRtr 0 }
radRTED OBJECT IDENTIFIER ::= {radSysRtr 1} -- RAD Router products
radRTEM OBJECT IDENTIFIER ::= {radSysRtr 2} -- RAD Router products
radRTEC OBJECT IDENTIFIER ::= {radSysRtr 3} -- RAD Router products
radWebRanger OBJECT IDENTIFIER ::= {radSysRtr 4} -- RAD Router products
radTinyRouter OBJECT IDENTIFIER ::= {radSysRtr 5} -- RAD Router products
radLA240 OBJECT IDENTIFIER ::= {radSysRtr 6} -- RAD Router products
radSuperLan OBJECT IDENTIFIER ::= {radSysRtr 7} -- RAD Router products (LA-240)
radLA240I OBJECT IDENTIFIER ::= {radSysRtr 8} -- RAD Router products
radFcdIsdn OBJECT IDENTIFIER ::= {radSysRtr 9} -- RAD Router products
radEFcdIp OBJECT IDENTIFIER ::= {radSysRtr 10} -- RAD Router products (FCD-IP/D)
radFcdIpD OBJECT IDENTIFIER ::= {radSysRtr 11} -- RAD Router products
radFcdIpM OBJECT IDENTIFIER ::= {radSysRtr 12} -- RAD Router products (LA-240)
radSysAtm OBJECT IDENTIFIER ::= { systems 12 } -- RAD ATM products
radSysAtmEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD ATM products."
::= { radSysAtm 0 }
radStarSwitch OBJECT IDENTIFIER ::= {radSysAtm 1} --RAD StartSwitch products
radStarSwitchATM25 OBJECT IDENTIFIER ::= {radStarSwitch 1} --RAD StartSwitch products
radStarSwitchATM25L OBJECT IDENTIFIER ::= {radStarSwitch 2} --RAD StartSwitch products
radStarSwitchATM155 OBJECT IDENTIFIER ::= {radStarSwitch 3} --RAD StartSwitch products
radAtmCsuDsu OBJECT IDENTIFIER ::= {radSysAtm 2} --RAD CSU/DSU products
radAmcdE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 1} -- RAD CSU/DSU products
radAmcdT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 2} -- RAD CSU/DSU products
radAce20E OBJECT IDENTIFIER ::= {radAtmCsuDsu 3} -- RAD CSU/DSU products
radAce20T OBJECT IDENTIFIER ::= {radAtmCsuDsu 4} -- RAD CSU/DSU products
radAce2005 OBJECT IDENTIFIER ::= { radAtmCsuDsu 5} -- RAD ACE2005
radAce2002 OBJECT IDENTIFIER ::= { radAtmCsuDsu 6} -- RAD ACE2002
radAce2002E OBJECT IDENTIFIER ::= { radAtmCsuDsu 7} -- RAD ACE2002E
radAce2E OBJECT IDENTIFIER ::= {radAtmCsuDsu 8} -- RAD CSU/DSU products
radAce2T OBJECT IDENTIFIER ::= {radAtmCsuDsu 9} -- RAD CSU/DSU products
radMlAtmE1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 10} -- RAD ATM Piggy
radMlAtmT1 OBJECT IDENTIFIER ::= {radAtmCsuDsu 11} -- RAD ATM Piggy
radAmc102 OBJECT IDENTIFIER ::= {radAtmCsuDsu 12} -- RAD AMC102
radAmc102c OBJECT IDENTIFIER ::= {radAtmCsuDsu 13} -- RAD AMC102 CARD
radAce202 OBJECT IDENTIFIER ::= { radAtmCsuDsu 14} -- RAD ACE202
radAce OBJECT IDENTIFIER ::= {radSysAtm 3} --RAD ACE products
radAce101 OBJECT IDENTIFIER ::= {radAce 1} -- RAD ACE101
radAce102 OBJECT IDENTIFIER ::= {radAce 2} -- RAD ACE102
radAce50 OBJECT IDENTIFIER ::= {radAce 3} -- RAD ACE50
radAce52 OBJECT IDENTIFIER ::= {radAce 4} -- RAD ACE52
radSysLA OBJECT IDENTIFIER ::= {systems 13} --RAD IAD (Integrated Access Device) products
radLA140 OBJECT IDENTIFIER ::= {radSysLA 1} -- RAD LA-140
radLA110 OBJECT IDENTIFIER ::= {radSysLA 2} -- RAD LA-110
radLA104 OBJECT IDENTIFIER ::= {radSysLA 3} -- RAD LA-104 (LA-110 with IMA)
radSysTerminal OBJECT IDENTIFIER ::= {systems 100} --RAD Terminal Meta-MIB;
-- no objects should be added to this branch in RAD MIB.
agnt OBJECT IDENTIFIER ::= { radGen 2}
-- agent general tree
-- Agent General
agnHwVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ASCII string for description and display of the agent hardware version,
as it is known by the agent software.The user can update the version
upon request when he changes components in the agent's module "
::= { agnt 1 }
agnTrapMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines the type of traps the
agent should mask and not send to the management console. The
value is differently determined for different products. There are
mainly two methods:
- an integer number, specifying the traps' severity.
- a sum of 2**n, where n is a bit assigned to a certain
masked trap group.
User should consult the product specification, to find out
the method employed."
::= { agnt 2 }
agnTrapValue OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The value of the trap decoded in internal RAD format. Full description is given
in the Trap definition file"
::= {agnt 3}
agnChangeCnt OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of changes in system configuration that were reported to the
manager since last cold start"
::= {agnt 4 }
agnSpecific OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Object identifier of entity containing additional information
regarding this instance."
::= { agnt 5}
agnConfigMsg OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Full configuration message coded in internal RAD application format.
This entry describes agent's configuration.
For MP-2200 R3, this object describes agent's support of the V5.1
feature: 1 octet ; bit 0 (LSB).
'1' - V5.1 feature is supported
'0' - V5.1 feature is not supported."
::= { agnt 6 }
-- Manager table to record all IP addresses
mngTrapIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF MngEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table indicates the destination address of the traps.
Internally it will be limited to ten addresses. "
::= { agnt 7 }
mngEntry OBJECT-TYPE
SYNTAX MngEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { mngID }
::= { mngTrapIpTable 1 }
MngEntry ::=
SEQUENCE {
mngID
Integer32,
mngIP
IpAddress,
mngIPMask
IpAddress,
mngTrapMask
Integer32
}
mngID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This value indicates an index of a specific IP address"
::= { mngEntry 1 }
mngIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value indicates the destination address of the traps. IP 0.0.0.0 removes the entry. "
::= { mngEntry 2 }
mngIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This value indicates the mask of the destination addresses of the traps. "
::= { mngEntry 3 }
mngTrapMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines the type of traps the
agent should mask and not send to this NMS. The
value is differently determined for different products. There are
mainly two methods:
- an integer number, specifying the traps' severity.
- a sum of 2**n, where n is a bit assigned to a certain
masked trap group.
User should consult the product specification, to find out
the method employed."
::= { mngEntry 4 }
agnIndication OBJECT-TYPE
SYNTAX INTEGER {
faulty (1), -- =major
warning (2),
normal (3), -- off
minor (4),
major (5),
event (6),
critical(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Attribute describing the state of the entity the agent is responsible for.
In case of a modular entity, the value of this attribute will be according
to the component which is in the worst state.
The order of severity (from top to bottom) is:
critical-> major (or faulty)-> minor-> event-> warning-> normal (off)."
::= { agnt 8 }
agnMonitorModeCmd OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
off(2),
on(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce the agent to change its mode of operation to
Monitor Mode"
::= {agnt 9}
agnLed OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status of the agent module . Each led will be represented by 4
bits where the first 2 bits (left) will specify the status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the next two bits (right) will specify the color :
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY)"
::= {agnt 10}
trapTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the last few traps generated by the agent, for future retrieval. The table
has a limited capacity. If traps are not retrieved in proper time, they will be
over-written by new traps "
::= {agnt 11}
trapEntry OBJECT-TYPE
SYNTAX TrapEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { trapID }
::= { trapTable 1 }
TrapEntry ::=
SEQUENCE {
trapID
Integer32,
trapVal
DisplayString,
trapTimeSinceOccurrence
TimeTicks
}
trapID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" This value indicates an index of a specific trap "
::= { trapEntry 1 }
trapVal OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value is the actual ASCII description of the trap. "
::= { trapEntry 2 }
trapTimeSinceOccurrence OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value indicates the amount of time passed since the occurrence of the event that
trigger this trap. "
::= { trapEntry 3 }
fileTransfer OBJECT IDENTIFIER ::= { agnt 12 }
fileServerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IP address of the server from which the file is loaded "
::= { fileTransfer 1 }
fileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The name of the file to be loaded. For protection, read returns
NULL. "
::= { fileTransfer 2 }
fileTransCmd OBJECT-TYPE
SYNTAX INTEGER {
swDwnLoad (1),
configDwnLoad (2),
configUpLoad (3),
coProcDwnLoad (4),
stateUpLoad (5),
dwnLoadUserFile (6),
upLoadUserFile (7),
swDwnLoadAndReset (8),
swUpLoad (9),
noOp (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The command to be executed on fileName at fileServerIP."
::= { fileTransfer 3 }
-- tftp group
tftpRetryTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" General Retransmission time-out value (seconds) "
-- DEFVAL { 15 }
::= { fileTransfer 4 }
tftpTotalTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Total Retransmission time-out value (seconds) "
-- DEFVAL { 60 }
::= { fileTransfer 5 }
tftpStatus OBJECT-TYPE
SYNTAX INTEGER {
noOp(2),
connecting(3),
transferringData(4),
endedTimeOut(5),
endedOk(6),
error(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Status of tftp session. When a session ended with success,
the tftpStatus should be endedOk(6). Before restarting a
tftp session, the NMS should set the tftpStatus to noOp(2).
That's the reason of MAX-ACCESS read-write to this field."
DEFVAL { noOp}
::= { fileTransfer 6 }
tftpError OBJECT-TYPE
SYNTAX OCTET STRING ( SIZE(2) )
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The MSB represents the standard error code.
The LSB represents the private error code.
0x0000 is No Error
0x0100 is File Not Found
0x0400 is Illegal TFTP operation
0x0500 is Unknown transfer ID
0x0001 is Server Overflow
0x0002 is No empty UDP port
0x0003 is No empty connection
0x0004 is Illegal File Mode
0x0007 is Illegal PDU size "
DEFVAL { '0000'h }
::= { fileTransfer 7 }
fileTransferToSubSystems OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object represents the sub-systems the fileTransCmd
refers to. It should be used when a system is divided
to sub-systems and each sub-system (or part of them) can
have a different SW/Configuration.
Each bit of this object will represent one of the sub-systems.
Bit='1' - APPLY to respective sub-system
Bit='0' - DO NOT APPLY to respective sub-system
For the meaning of each bit, see product's specification.
User will select the sub-systems envolved by filling-in the bits
that represent these sub-systems.
In this case, the file represented by 'fileName' will
include several parts, each representing one of the sub-systems.
The agent will refer only to the part/s indicated by this object.
0 Octet Strings = not applicable
DEFVAL = 0h for the products that support this object."
::= { fileTransfer 8 }
fileNameWithinProduct OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The file name used by the product within the product file system."
::= { fileTransfer 9 }
--Internal SW Download table
intSwdlTable OBJECT-TYPE
SYNTAX SEQUENCE OF IntSwdlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This parameters table is for
internal Software down load. It also includes data
about all files contained in the Object from which
down-load is performed."
::= { fileTransfer 10 }
intSwdlEntry OBJECT-TYPE
SYNTAX IntSwdlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {intSwdlObjIdx, intSwdlFileIdx }
::= { intSwdlTable 1}
IntSwdlEntry ::=
SEQUENCE {
intSwdlObjIdx Integer32,
intSwdlFileIdx Integer32,
intSwdlFileName DisplayString,
intSwdlFileSwVer DisplayString,
intSwdlSwDate DisplayString,
intSwdlSize DisplayString,
intSwdlCmd INTEGER,
intSwdlToSubSystem OCTET STRING
}
intSwdlObjIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the object from which down-load is performed."
::= {intSwdlEntry 1}
intSwdlFileIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the files included in intSwdlObjIdx.
One of these files can be selected to be internally
downloaded."
::= {intSwdlEntry 2}
intSwdlFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the file."
::= {intSwdlEntry 3}
intSwdlFileSwVer OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software version of the file."
::= {intSwdlEntry 4}
intSwdlSwDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The software version date of the file."
::= {intSwdlEntry 5}
intSwdlSize OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The size of the file."
::= {intSwdlEntry 6}
intSwdlCmd OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The command to down-load a SW file to an object.
The Agent will change the value of this MIB object to off(2)
automatically, after accepting the command."
::= {intSwdlEntry 7}
intSwdlToSubSystem OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object defines the subsystem for download.
Bit='1'- APPLY to respective sub system.
Bit='0'- DO NOT APPLY to respective sub system.
For more details see product specification.
For every octet bit0=LSB, bit7=MSB"
::= { intSwdlEntry 8 }
--SW Download Status table
swdlStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SwdlStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This parameters table is for software download status.
It also includes data about the files down-loaded or
attempted to be down-loaded."
::= { fileTransfer 11 }
swdlStatusEntry OBJECT-TYPE
SYNTAX SwdlStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {swdlStatusTypeIdx, swdlStatusIdx }
::= { swdlStatusTable 1}
SwdlStatusEntry ::=
SEQUENCE {
swdlStatusTypeIdx Integer32,
swdlStatusIdx Integer32,
swdlStatusFileName DisplayString,
swdlStatusSlot DisplayString,
swdlStatusSubSystem DisplayString,
swdlStatusStatus Integer32,
swdlStatusTime DisplayString
}
swdlStatusTypeIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the down-load type (e.g. external (1) or internal (2))."
::= {swdlStatusEntry 1}
swdlStatusIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the status rows."
::= {swdlStatusEntry 2}
swdlStatusFileName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the file."
::= {swdlStatusEntry 3}
swdlStatusSlot OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The slot of the updated (or attempted to be updated) object."
::= {swdlStatusEntry 4}
swdlStatusSubSystem OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The subsystem that updated (or attempted to be updated)."
::= {swdlStatusEntry 5}
swdlStatusStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the down load process.
Value: Fail (2), OK (3), InProcess (4)."
::= {swdlStatusEntry 6}
swdlStatusTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This MIB parameter indicates the time SW download was finished.
The format shuld be YYYY-MM-DD, hh:mm:ss"
::= {swdlStatusEntry 7}
clearDwldStatusLog OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object clears the status log.
Value: off(2), external(3), internal(4)
The Agent will change the value of this MIB object to off(2)
automatically, after accepting the command ."
::= { fileTransfer 12 }
systemReset OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3), --HW
resetConfig (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset action to be performed on the system."
::= { agnt 13 }
systemTiming OBJECT IDENTIFIER ::= { agnt 14 }
systemDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System date."
::= { systemTiming 1 }
systemTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"System time."
::= { systemTiming 2 }
systemPort OBJECT IDENTIFIER ::= { agnt 15 }
physicalConnectorTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhysicalConnectorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes the connector type of ports or interfaces."
::= {systemPort 1}
physicalConnectorEntry OBJECT-TYPE
SYNTAX PhysicalConnectorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {portIdx}
::= { physicalConnectorTable 1 }
PhysicalConnectorEntry ::=
SEQUENCE {
portIdx
Integer32,
physicalConnector
INTEGER,
portOptWaveLength
INTEGER,
portOptMode
INTEGER,
portBalance
INTEGER
}
portIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used."
::= { physicalConnectorEntry 1 }
physicalConnector OBJECT-TYPE
SYNTAX INTEGER
{
other (1),
v35 (2), --34 pin female
rs530 (3), --DB25
x21 (4), --DB15
bnc (5),
utp (6), --RJ45
aui (7),
rs422 (8), --DB25
crossUtp (9), --RJ45
rj45 (10),
v24 (11), --DB25
g703 (12), --TB5
termBlock3AndRj45 (13),
terminalBlock3 (14),
terminalBlock5 (15),
terminalBlock7 (16),
db25 (17),
db15 (18),
rj45ethernet (19),
termBlock5AndRj45 (20),
db9 (21),
g703E1 (22), --BNC-RJ45-BNC
g703E1-LTU (23), --BNC-RJ45-BNC
sc (24), --sc optical
st (25), --st optical
stl (26),
fc (27), --fc optical
tb5w (28), --Term-Block-5-Wire (for HCD)
termBlock6AndRj45 (29),
ethBnc (30),
scsi26 (31), --SCSI with 26 pins
eth4381 (32), --RJ45 with two embeded LEDs
twoBnc (33), --Two BNC
scsi50 (34), --SCSI with 50 pins
twoMiniBnc (35), --Two mini BNC
sf1 (36), --sf1=single fiber optical
terminalBlock4 (37),
sf2 (38), --sf2=single fiber optical
db25Balanced (39), --DB25 Balanced
v36 (40),
block4W (41), --like in WR connector for Modems
iripRj45 (42),
irEthQRj45 (43),
iripBnc (44),
rs530WA (45), --rs530/IR that solves a wander problem for SDH network
v35WA (46), --v35/IR that solves a wander problem for SDH network
irEthQBnc (47),
v35Db25 (48), --V.35 with connector DB25
rj11 (49), --Used for FXS & FXO
mtrj (50), --optical
lc (51), --optical
terminalBlock2 (52),
irEth10s100 (53), --IR-ETH 10/100
scsi68 (54), -- SCSI 68 pins
sf3 (55), -- sf3=single fiber of sc optical
fcLH (56), -- fc Long Haul
telco50 (57), -- TELCO 50
telco64 (58), -- TELCO 64
irEthQN (59),
none (255)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The connector of the port/interface.
other - none of the specified connectors
none - no connector."
::= { physicalConnectorEntry 2 }
portOptWaveLength OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
nm850(2),
nm1300(3),
nm1300Laser(4),
nm1550Laser(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Wave Length of an Optical interface/port in [nm] and specification if
Laser or not.
notApplicable - for non-optical ports."
::= { physicalConnectorEntry 3 }
portOptMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
singleMode(2),
multiMode(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Laser Mode of an Optical Laser interface/port.
notApplicable - for non-Laser ports."
::= { physicalConnectorEntry 4 }
portBalance OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
unbalanced (2),
balanced (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is according to the port Impedance.
For T1 - always balanced.
For E1 - there are different impedance values for balanced
and unbalanced."
::= { physicalConnectorEntry 5 }
prtSupervisory OBJECT IDENTIFIER ::= { systemPort 2 }
prtSpTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= {prtSupervisory 1}
prtSpEntry OBJECT-TYPE
SYNTAX PrtSpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Supervisory port parameter table."
INDEX {prtSupervisoryIndex }
::= { prtSpTable 1}
PrtSpEntry ::=
SEQUENCE {
prtSupervisoryIndex Integer32,
prtSupervisoryRate INTEGER,
prtSupervisoryDataBits INTEGER,
prtSupervisoryParity INTEGER,
prtSupervisoryStopBits INTEGER,
prtSupervisoryUsage INTEGER,
prtSupervisoryInterface INTEGER,
prtSupervisoryCTS INTEGER,
prtSupervisoryDcdDelay INTEGER,
prtSupervisoryDSR INTEGER,
prtSupervisoryRoutProtocol INTEGER
}
prtSupervisoryIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The SP port index.
For some products, having modules (cards):
The LS byte of the integer is the port index 1..255.
The MS byte is different than 0 only if the port belongs to
a module. In that case it is the module number.
For other products' index see their specification."
::= { prtSpEntry 1}
prtSupervisoryRate OBJECT-TYPE
SYNTAX INTEGER
{
auto (1),
s300bps (2),
s1200bps (3),
s2400bps (4),
s4800bps (5),
s9600bps (6),
s19200bps (7),
s38400bps (8),
s57600bps (9),
s115200bps (10)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the operation rate (speed) of the
port.
auto - automatic rate selection, by the agent."
::= { prtSpEntry 2}
prtSupervisoryDataBits OBJECT-TYPE
SYNTAX INTEGER
{
dataBits7 (1),
dataBits8 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the number of data bits in an async
frame"
::= { prtSpEntry 3}
prtSupervisoryParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity mode in an async frame"
::= { prtSpEntry 4}
prtSupervisoryStopBits OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
stopBits1 (2),
stopBits1dot5 (3),
stopBits2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the parity mode in an async frame."
::= { prtSpEntry 5}
prtSupervisoryUsage OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
noUse (2),
terminal(3),
nmsSlip (4),
nmsPpp (5),
muxSlip (6),
muxPpp (7),
dialOut (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the usage of the SP port."
::= { prtSpEntry 6}
prtSupervisoryInterface OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
dce (2),
dte (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the supervisory port interface."
::= { prtSpEntry 7}
prtSupervisoryCTS OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2), --Old value for DCE.
rts (3), --Old value for DCE
dteWait (4), --DTE will wait for CTS to become active before transmit date.
dteIgnore (5) --DTE will Ignore CTS signal and will transmit date anyway.
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CTS line state."
::= { prtSpEntry 8}
prtSupervisoryDcdDelay OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
d0 (2),
d10 (3),
d50 (4),
d100 (5),
d200 (6),
d300 (7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCD delay in msec."
::= { prtSpEntry 9}
prtSupervisoryDSR OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
on (2),
dtr (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DSR line state."
::= { prtSpEntry 10}
prtSupervisoryRoutProtocol OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
proprietary (3),
rip2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute indicates the routing protocol of the port.
notApplicable - for DP."
::= { prtSpEntry 11}
--Port Performance Data
prtPerformance OBJECT IDENTIFIER ::= { systemPort 3 }
prtPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes G.826 ports or interfaces."
::= {prtPerformance 1}
prtPerfEntry OBJECT-TYPE
SYNTAX PrtPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtPerfIdx, prtPerfPeriodRef}
::= { prtPerfTable 1 }
PrtPerfEntry ::=
SEQUENCE {
prtPerfIdx
Integer32,
prtPerfPeriodRef
INTEGER,
prtPerfElapsedTime
Integer32,
prtPerfUAS
Integer32,
prtPerfES
Integer32,
prtPerfSES
Integer32,
prtPerfBBE
Integer32,
prtPerfBlocksPerSec
Integer32,
prtPerfTimeTag
TimeTicks,
prtPerfSaveAndResetCmd
INTEGER
}
prtPerfIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used."
::= { prtPerfEntry 1 }
prtPerfPeriodRef OBJECT-TYPE
SYNTAX INTEGER
{
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
5 objects refer to.
currentPeriod - the period since last prtPerfSaveAndResetCmd received or
since Start-up (if no prtPerfSaveAndResetCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of prtPerfSaveAndResetCmd.
- If only one command occured since Start-up: the period between
Start-up and last command.
- If no command occured since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { prtPerfEntry 2 }
prtPerfElapsedTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed Time in seconds.
- for prtPerfPeriodRef=currentPeriod:
The period since last prtPerfSaveAndResetCmd received or since Start-up
(if no prtPerfSaveAndResetCmd was received since Start-up) until now.
- for prtPerfPeriodRef=lastPeriod:
The value of prtPerfElapsedTime when last prtPerfSaveAndResetCmd
was received."
::= { prtPerfEntry 3 }
prtPerfUAS OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Unavailable Seconds for the reference period (prtPerfPeriodRef)."
::= { prtPerfEntry 4 }
prtPerfES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Errored Seconds for the reference period (prtPerfPeriodRef)."
::= { prtPerfEntry 5 }
prtPerfSES OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Severely Errored Seconds for the reference period (prtPerfPeriodRef)."
::= { prtPerfEntry 6 }
prtPerfBBE OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Background Block (or Frame) Errors for the reference period
(prtPerfPeriodRef)."
::= { prtPerfEntry 7 }
prtPerfBlocksPerSec OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Blocks per second (or frames per second) of the port/interface indicated by
portIdx. This object is constant for a certain port/interface.
It is not affected by the prtPerfPeriodRef index."
::= { prtPerfEntry 8 }
prtPerfTimeTag OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time Tag of Last Period: sysUpTime when last prtPerfSaveAndResetCmd was
executed.
This object is applicable only for prtPerfPeriodRef=lastPeriod.
For prtPerfPeriodRef=currentPeriod, the value will always be 0."
::= { prtPerfEntry 9 }
prtPerfSaveAndResetCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A command per port/interface, to Save data of Current Period in Last Period
data-set and start a new counting period for Current Period.
This object is applicable only for prtPerfPeriodRef=currentPeriod.
Setting this object to on(3) for prtPerfPeriodRef=last, will cause the agent
to return: Bad Value response.
When setting validly this object to on(3), agent will perform the required
command and will reset automatically the value of this object to off(2).
Setting this object to off(2), will do nothing."
::= { prtPerfEntry 10 }
--Port Test Data
prtTest OBJECT IDENTIFIER ::= { systemPort 4 }
prtTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes test data for ports or interfaces."
::= {prtTest 1}
prtTestEntry OBJECT-TYPE
SYNTAX PrtTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtTestIdx}
::= { prtTestTable 1 }
PrtTestEntry ::=
SEQUENCE {
prtTestIdx
Integer32,
prtTestCmdAndStatus
Integer32,
prtBertCounter
Integer32,
prtTestInitiator
INTEGER,
prtTestTimeout
Integer32
}
prtTestIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used."
::= { prtTestEntry 1 }
prtTestCmdAndStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to a value as detailed further on
(except 0) will initiate a test on the specific port.
The test/s requested will be set according to the respective
bit. The value of this object will be a sum of (2**n), where n is
the Bit:
TEST BIT VALUE
----------- --- ------
reserved 0 1
PayloadLoop=RLB 1 (=Remote Loopback) 2
LineLoop=DIG 2 (=Digital) 4
OtherLoop 3 8
InwardLoop=LLB 4 (=Local Loopback) 16
BERT 5 32
LC 6 64
ToneInjection 7 128
Inband 8 256
e.g : If the requested value is 20 -> 010100 ->
Bits 2 & 4 are set -> the requested tests are :
LineLoopback=DIG
InwardLoopback=LLB
Not all tests combinations are valid.
For valid test combination, see each product's specification.
For LRS52, only single test is allowed simultaneously
The terminology and order of the first tests (except BERT)
is according to the one used for Test Status of DS1 and DS3 standards.
The notations : RLB, LLB, DIG are the most used in RAD's products, but they
can be different. For exact definition see product's spec.
Setting this object to stop (value=0 ; all bits are 0),
will stop all the user requested tests running on the
selected port.
When no test is running on the port, the Get value (test status)
will be 0.
PayloadLoop=RLB
The received signal at this interface is looped
through the device. Typically the received signal
is looped back for retransmission after it has
passed through the device's framing function.
LineLoop=DIG
The received signal at this interface does not
go through the device (minimum penetration) but
is looped back out.
OtherLoop
Loopbacks that are not defined here.
InwardLoop=LLB
The sent signal at this interface is looped back
through the device.
LC
This loop is applicable only for HSSI interface, towards the router .
ToneInjection
This loop is applicable for analog voice (like FXS)."
::= { prtTestEntry 2 }
prtBertCounter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the number of BERT errors encountered
during the BERT operation.
It is valid only when BERT (Bit Error Rate Test) is active on the
specific port.
The Counter starts from zero (0) anytime BERT is initiated."
::= { prtTestEntry 3}
prtTestInitiator OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
user (2),
remoteUnit(3),
dteRouter (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates who initiated this port's test/s."
::= { prtTestEntry 4 }
prtTestTimeout OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is applicable only when a single
test is running. It indicates the test
activation timeout in minutes.
When the timeout expires, the test is stopped.
Value of 0 indicates test may run Forever "
::= { prtTestEntry 5 }
--Port General Parameters
prtParam OBJECT IDENTIFIER ::= { systemPort 5 }
prtParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table includes general port parameters. The meaning is
different for every product that supports it due to a general
parameter - prtControlCnfg.
For ACE2002:
-This table is used as a mechanism to create the next interface index.
The algorithm description:
The NMS will send the agent the following get command: get(nextIfIndex.index),
where index=interface on which the new index is dependent on.
Upon this command the agent will generate and return the new index to the NMS.
- This table is partially supported according to the interface type.
Upon getNext function the irrelevant parameters will be skipped."
::= {prtParam 1}
prtParamEntry OBJECT-TYPE
SYNTAX PrtParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtParamIdx}
::= { prtParamTable 1 }
PrtParamEntry ::=
SEQUENCE {
prtParamIdx
Integer32,
prtControlCnfg
Integer32,
prtParamClkSrc
INTEGER,
prtParamPhantom
INTEGER,
prtParamResetStatsCmd
INTEGER,
prtParamLastResetStatsTime
TimeStamp,
prtParamInterfaceType
INTEGER,
prtParamClearAlarm
INTEGER,
prtParamLeds
OCTET STRING
}
prtParamIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index of the specific port or interface.
For a port, the index will be as agreed between agent and
application.
For an interface, ifIndex may be used.
For ACE2002:
This parameter is the physical layer ifIndex of the slot on
which the NMS requires the next interface index."
::= { prtParamEntry 1 }
prtControlCnfg OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object may be used for port RW general parameter/s.
For detailed meaning, see product's spec.
Supported by: PRBi-E3/T3.
For ACE2002:
This parameter will include the value of the new index
generated by agent.
For Optimux-T3 and OP-155-1:
This parameter will be used for Release Remote LLB Command:
on=2= Set value only. Command to release LLB of Remote Unit.
Agent will return automatically to 'off' value after performing
the command.
off=3=Get value only.
For LA140
This parameter will be used as EchoCanceler per timeslot
off = 2 Echo Canceler is disabled
on = 3 Echo Canceler is enabled
For FCD-155
This parameter will be used to select the port that is
clock source for a PDH port, when 2495.dsx1TransmitClockSource=throughTiming.
VC12/VT1.5 = 2
SDH/SONET = 3
For ACE-52
This parameter will be used as Transmit Frame Type, i.e.
which type of frame the corresponding bridge port will transmit:
Untagged = 2
Tagged = 3
."
::= { prtParamEntry 2 }
prtParamClkSrc OBJECT-TYPE
SYNTAX INTEGER {
loopTiming (1),
localTiming (2),
throughTiming (3),
adaptive (4),
master (5),
fallback (6),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of Transmit Clock.
'loopTiming' or 'loopback' indicates that the recovered receive clock
is used as the transmit clock.
'localTiming' or 'internal' indicates that a local clock
source is used or when an external clock is
attached to the box containing the interface.
'throughTiming' or 'external' indicates that recovered receive clock
from another card or interface is used as the transmit clock.
'adaptive' indicates that the clock is recovered according
to the received data flow rate.
'master' and 'fallback' values may be used RO to
indicate active clock."
::= { prtParamEntry 3 }
prtParamPhantom OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Power feeding to another device."
::= { prtParamEntry 4 }
prtParamResetStatsCmd OBJECT-TYPE
SYNTAX INTEGER {
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset statistics of the selected port."
::= { prtParamEntry 5 }
prtParamLastResetStatsTime OBJECT-TYPE
SYNTAX TimeStamp
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of MIB II's sysUpTime object at the last time that
prtParamResetStatsCmd was Set to on(3) for this port.
If prtParamResetStatsCmd was never Set to on(3) since last
re-initialization of the agent, then this object contains a zero value.
This object enables calculating the running time of Statistics
counters for this port, by: [sysUpTime-prtParamLastResetStatsTime].
For some devices other types of 'Reset' may affect this parameter"
::= { prtParamEntry 6 }
prtParamInterfaceType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
e1 (2),
t1 (3),
fr (4),
hdlc (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of the port."
::= { prtParamEntry 7 }
prtParamClearAlarm OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this attribute to ON, will enforce a clear
operation on the Port Alarms.
Upon completion, the value will automatically change
to off(2)."
::= { prtParamEntry 8 }
prtParamLeds OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status of the port.
Each led is represented by 4 bits where the first 2 bits
(left) specify the status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the next two bits (right) specify the color :
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY).
The order of the LEDS is from top to bottom, left to right:
For each row starting from the top,
the LEDS are returned from left to right."
::= {prtParamEntry 9}
prtIP OBJECT IDENTIFIER ::= { systemPort 6 }
prtIpParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtIpParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table - Parameters for IP Ports."
::= {prtIP 1}
prtIpParamEntry OBJECT-TYPE
SYNTAX PrtIpParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { prtIpParamConfigIdx, prtIpParamSlotIdx, prtIpParamIdx }
::= { prtIpParamTable 1 }
PrtIpParamEntry ::=
SEQUENCE {
prtIpParamConfigIdx Integer32,
prtIpParamSlotIdx Integer32,
prtIpParamIdx Integer32,
prtIpParamHostIP IpAddress,
prtIpParamHostMask IpAddress,
prtIpParamDefaultGateway IpAddress,
prtIpParamMediaMode INTEGER,
prtIpParamMediaRate INTEGER,
prtIpParamMngVlanSupport INTEGER,
prtIpParamMngVlanId Integer32,
prtIpParamMngVlanPriority Integer32,
prtIpParamRingMode INTEGER,
prtIpParamProtIpEnable INTEGER,
prtIpParamTrafficPriority INTEGER,
prtIpParamRemoteIP IpAddress,
prtIpParamMaxTxBandwidth INTEGER
}
prtIpParamConfigIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Configuration number (1..255)
referred.
Value of 255 specifies the TmpCnfg (Scratch).
For products having Agent and Edit configurations,
Write operation for the table entries is allowed only to
Config=255."
::= { prtIpParamEntry 1 }
prtIpParamSlotIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique number of the slot position
in which the module is inserted.
notApplicable = 255 (for products that don't have slots).
For KM:
kmxMlA (103),
kmxMlB (104)."
::= { prtIpParamEntry 2 }
prtIpParamIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique Port Index."
::= { prtIpParamEntry 3 }
prtIpParamHostIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The host interface IP address."
::= { prtIpParamEntry 4 }
prtIpParamHostMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The host interface subnet mask."
::= { prtIpParamEntry 5 }
prtIpParamDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Gateway's IP Address."
::= { prtIpParamEntry 6 }
prtIpParamMediaMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
halfDuplex (2),
fullDuplex (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the real Media Mode."
::= { prtIpParamEntry 7 }
prtIpParamMediaRate OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
r10Mbps (2),
r100Mbps (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the real Media Rate (Mbps)."
::= { prtIpParamEntry 8 }
prtIpParamMngVlanSupport OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management VLAN support (Tagging).
no - No support of VLAN Tagging.
yes - 4 VLAN bytes will be added to the frame."
::= { prtIpParamEntry 9 }
prtIpParamMngVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management VLAN ID."
::= { prtIpParamEntry 10 }
prtIpParamMngVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management VLAN Frame priority."
::= { prtIpParamEntry 11 }
prtIpParamRingMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates If Ring Mode is enabled or not."
::= { prtIpParamEntry 12 }
prtIpParamProtIpEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether a list of Protected IP Addresses
is enabled or not. This object is applicable only if
prtIpParamRingMode=enable."
::= { prtIpParamEntry 13 }
prtIpParamTrafficPriority OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
low (2),
high (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the traffic priority of this port."
::= { prtIpParamEntry 14 }
prtIpParamRemoteIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This is the IP Address of the remote device that is connected to the
current device (Point to Point Application). It is used for sending OAM packets
on the LAN to the remote side in order to check that the connection is OK."
::= { prtIpParamEntry 15 }
prtIpParamMaxTxBandwidth OBJECT-TYPE
SYNTAX INTEGER
{
full (2),
e1 (3),
t1 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object shows the Max Bandwidth allowed on the LAN.
Full - means that a Maximum of 100 Mega Byte Rate may go through the LAN.
e1(3) means that the maximum is an E1 rate. t1(4) is for a maximum of a T1 rate."
::= { prtIpParamEntry 16 }
prtClkSrc OBJECT IDENTIFIER ::= { systemPort 7 }
prtClkSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table - Parameters for master and fallback
clock source of ports ."
::= {prtClkSrc 1}
prtClkSrcEntry OBJECT-TYPE
SYNTAX PrtClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtClkSrcCnfgIdx, prtClkSrcPrtIdx, prtClkSrcIdx}
::= { prtClkSrcTable 1}
PrtClkSrcEntry ::=
SEQUENCE {
prtClkSrcCnfgIdx Integer32,
prtClkSrcPrtIdx Integer32,
prtClkSrcIdx INTEGER,
prtClkSrcMode INTEGER,
prtClkSrcPrt Integer32
}
prtClkSrcCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { prtClkSrcEntry 1}
prtClkSrcPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates a unique Port Index (receiving clock).
Refer to device specification for port Index"
::= { prtClkSrcEntry 2}
prtClkSrcIdx OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback (2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An index in the table.
master - refers Master clock parameters
fallback - refers Fallback clock parameters"
::= { prtClkSrcEntry 3}
prtClkSrcMode OBJECT-TYPE
SYNTAX INTEGER
{
-- none (1),
internal (2),
rxClk (3),
-- station (4),
-- lbt (5),
-- ntr (6),
-- adaptive (7),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the source the nodal timing is
locked to. "
::= { prtClkSrcEntry 4}
prtClkSrcPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid only when working in rxClk mode.
It specifies the port from which the clock willl be taken.
Refer to device specification for source port Index"
::= { prtClkSrcEntry 5}
systemResetAllStatsCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset statistics of all ports and connections of the device."
::= { agnt 16 }
systemClearTablesCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
tempCnfgTables (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"tempCnfgTables - Set *RowStatus = destroy for all entries of
some tables having *RowStatus object, for
temporary configuration only! (255).
For the relevant tables, see product's specification.
This object should be used by WAN product applications
before performing the Update operation, in order to clear
old entries of these tables.
For MP-104/204 the entries will be destroyed for cnfg=1.
off - agent will automatically change to this value, after performing the
command. "
::= { agnt 17 }
systemParameter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter can be used for different purposes:
- TELNET session time-out in seconds.
- Ace20: when trying to create row in a table that already
has row with the same values, if set of values has to be unique
in table, this attribute is set to the index of the existing row.
- Optimux-T3: when CH interfaces are RJ-45, user can select via this
object, the interface type for each Group of channels: T1 or E1:
The selection will be a sum of the following Bits.
'0' = T1
'1' = E1
Bit Group Value for each Bit having '1'
1 1 (CH-1..CH-8) 1
2 2 (CH-9..CH-12) 2
3 3 (CH-13..CH-20) 4
4 4 (CH-21..CH-28) 8
Examples:
15 = all Groups are selected to be E1
6 = Group 2 and Group 3 are selected to be E1
(Group 1 and Group 4 are T1).
- FCD-A, FCD-M: user can select via this object the configuration
used for Get values of MSDSL parameters that don't have
configuration index.
1 =active configuration
255=temporary configuration.
Set of this object should be done before Getting the MSDSL
RW parameters.
- Ace2002: This parameter indicates the number of intervals that
were successfully uploaded upon statistics collection session.
- FCD-IP, WR, FCD-IPD, LA-240:
This parameter indicates whether Telnet Access is enabled/disabled:
Values:
2 - Telnet Access is Disabled.
3 - Telnet Access is Enabled.
-Vmux-110: This parameter value equals to maximum number of bundles.
-Optimux-155: Simmilar usage to Optimux T3. user can select via this
object, interface type T1 or E1 for each Group of
channels (LIU): LIU group consists of 7 channels.
Up to 12 LIUs are represented (84 T1 Channels).
The selection will be a sum of the 2**n
For each bit:'0' = T1 ,'1' = E1
Bit Group
1 1 (CH-1 .. CH-7)
2 2 (CH-8 .. CH-14)
3 3 (CH-15 ..CH-21)
...
9 9 (CH-56.. CH-63)
...
10 10 (CH-64..CH-70)
11 11 (CH-71..CH-77)
12 12 (CH-78..CH-84) "
::= { agnt 18 }
agnGlobalAlarmMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The value of this attribute determines the alarm traps the
agent should mask and not send to the managers.
Each bit from a certain octet represents a certain alarm."
::= { agnt 19 }
alarmSeverity OBJECT-TYPE
SYNTAX INTEGER
{
event (3),
minor (4),
major (5),
warning (6),
critical (7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the severity of the alarms."
::= { agnt 20 }
alarmState OBJECT-TYPE
SYNTAX INTEGER
{
off (2), -- End,
on (3) -- Start.
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"."
::= { agnt 21 }
agnTestStatus OBJECT-TYPE
SYNTAX INTEGER
{
off (2),
on (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current test status (for all levels: system,
card, port).
This attribute will be set to:
on(3): when there is at least one test in progress on the
system/card/port
off(2): when there is NO test in progress on the
system/card/port"
::= {agnt 22 }
systemSaveAndResetAllStatsCmd OBJECT-TYPE
SYNTAX INTEGER
{
off(2),
on (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"on - a command to Save data of Current Period in Last Period
data-set and start a new counting period for Current Period.
off - agent will automatically change to this value, after performing the
command."
::= { agnt 23 }
systemDefaultGateway OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Gateway's IP Address."
::= { agnt 24 }
-- PS Table
systemPsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table describes the PS types of a device.
Usage of this table is specified in the device's NMS SRS"
::= { agnt 25 }
systemPsEntry OBJECT-TYPE
SYNTAX SystemPsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {systemPsIndex1, systemPsIndex2}
::= { systemPsTable 1 }
SystemPsEntry ::=
SEQUENCE {
systemPsIndex1
Integer32,
systemPsIndex2
Integer32,
systemPsType
INTEGER,
systemPsStatus
INTEGER,
systemPsHotSwap
INTEGER
}
systemPsIndex1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"First Index.
In HUBs:
1 = PS-A slot
2 = PS-B slot.
In SA units:
1 = PS1
2 = PS2
Default = 1"
::= { systemPsEntry 1 }
systemPsIndex2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Second Index.
In HUBs:
1 always.
In SA units:
1 = Local
2 = Remote
Default = 1."
::= { systemPsEntry 2 }
systemPsType OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
ac (2),
dc (3),
acDc (4),
acPF (5),
dcPF (6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of PS, for a stand-alone product.
acDc - AC with rj45 DC.
acPF - Power Feeding (phantom) box that is feeding another box by external AC.
dcPF - Power Feeding (phantom) box that is feeding another box by external DC."
::= { systemPsEntry 3 }
systemPsStatus OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
failed (2),
ok (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Status of the PS unit."
::= { systemPsEntry 4 }
systemPsHotSwap OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
fixed (2),
hotSwap (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Is PS unit hot swap or fixed."
::= { systemPsEntry 5 }
agnFans OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the FANs existence and status.
Each fan will be represented by 2 bits,
where the first bit (right) will specify the existence:
(0= Not exist, 1=exist),
and the left bit will specify it's status
(0= OK, 1=FAIL), so for each fan:
00 - FAN does not exist
01 - FAN exists and OK
11 - FAN exists and is Failed
bits 0-1 are for first fan
bits 2-3 are for 2nd fan (if exists)."
::= { agnt 26 }
agnSendTrapParameter OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies if the agent will attach a specific
parameter to a trap.
For ACE2002 the agent will attach or not the openViewSeverity
parameter according to the value of this parameter:
1 - will attach openViewSeverity.
0 - will not attach openViewSeverity."
::= { agnt 27 }
agnSensorsStatus OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the Sensors (Temperature sensors or others)
existence and status.
Each sensor will be represented by 2 bits,
where the first bit (right) will specify the existence:
(0= Not exist, 1=exist),
and the left bit will specify it's status
(0= OK, 1=FAIL), so for each sensor:
00 - sensor does not exist
01 - sensor exists and status is OK
11 - sensor exists and status is not OK
( e.g. temperature exceeds pre-defined threshold)
bits 0-1 are for first sensor
bits 2-3 are for 2nd sensor (if exists)
and so on...
Bit 0 is the LSB."
::= { agnt 28 }
agnStationClockCard OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notExist (2),
notValid (3),
ok (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the station clock card
existence and status.
notExist - station clock card (piggy) does not exist.
notValid - station clock card exists but clock status is not valid.
ok - station clock card exists, and its status is OK "
::= { agnt 29 }
xcIndexNext OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to
be used for xcIndex when creating
entries in the xcTable. The value
0 indicates that no unassigned entries are
available. To obtain the xcIndex
value for a new entry, the manager issues a
management protocol retrieval operation to obtain
the current value of this object. After each
retrieval, the agent should modify the value to
the next unassigned index.
After a manager retrieves a value the agent will
determine through its local policy when this index
value will be made available for reuse."
::= { agnt 30 }
--XC Table
xcTable OBJECT-TYPE
SYNTAX SEQUENCE OF XcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Configuration of system cross-connect entries.
The table follows the behavior described in RFC 2515,
RFC 1604 regarding the creation deletion and modification
of an entry within the table."
::= { agnt 31 }
xcEntry OBJECT-TYPE
SYNTAX XcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { xcIndex, xcIfIndex1, xcVpi, xcVci, xcIfIndex2 }
::= { xcTable 1}
XcEntry ::=
SEQUENCE {
xcIndex Integer32,
xcIfIndex1 Integer32,
xcVpi Integer32,
xcVci Integer32,
xcIfIndex2 Integer32,
xcRowStatus RowStatus,
xcDescr DisplayString,
xcAdminStatus INTEGER,
xcOperStatus INTEGER,
xcAttachedIfType INTEGER,
xcInputPriority Integer32,
xcBitMapping Integer32
}
xcIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Cross Connect Identifier."
::= { xcEntry 1 }
xcIfIndex1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface Index from the ifTable, which identify one side
of the connection."
::= { xcEntry 2 }
xcVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VPI value."
::= { xcEntry 3 }
xcVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VCI value."
::= { xcEntry 4 }
xcIfIndex2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface Index from the ifTable, which identifies the other
side of the connection."
::= { xcEntry 5 }
xcRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter allows NMS to create/delete entries of this table."
::= { xcEntry 6 }
xcDescr OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"A textual string containing information about the
xc entry."
::= { xcEntry 7 }
xcAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The desired administrative status of this bi-directional
cross-connect."
::= { xcEntry 8 }
xcOperStatus OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The operational status of this bi-directional cross-connect."
::= { xcEntry 9 }
xcAttachedIfType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
free (2),
routerAtm (3),
lis (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates if the specific VCC is
already attached to any interface, and indicates
the type of the interface.
This object's purpose is to ease the checking to
the NMS.
notApplicable - used for entries that are not LAN (as HDLC),
or when the VCC was attached to a bridge, or
when this parameter is irrelevant.
free - the LAN VCC wasn't attached yet to any router
interface.
routerAtm - attached to an ATM router interface.
lis - attached to a LIS interface."
::= { xcEntry 10 }
xcInputPriority OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is the priority, by which the LAN frames will be
internaly sent to the ATM HW. This parameter is applicable if
atmNteMdlInputPriorityMechanism=enabled.
1 - Highest priority. Will be the first to be sent to the ATM HW.
4 - Lowest priority. Will be the last to be sent to the ATM HW."
::= { xcEntry 11 }
xcBitMapping OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object maps this entry to a bit of an octet string.
For ACE2002 this object maps the LAN VCC to the bit of the
VLAN Port Lists. If the value is '0' then it means that
this VCC is not mapped to a port list or it may be an HDSL
entry."
::= { xcEntry 12 }
systemModule OBJECT IDENTIFIER ::= { agnt 32 }
modlParam OBJECT IDENTIFIER ::= { systemModule 1 }
modlParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF ModlParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table include parameters for system modules."
::= { modlParam 1 }
modlParamEntry OBJECT-TYPE
SYNTAX ModlParamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { modlParamIndex }
::= { modlParamTable 1}
ModlParamEntry ::=
SEQUENCE {
modlParamIndex Integer32,
modlParamReset INTEGER,
modlParamSwdlStatus INTEGER,
modlParamLeds OCTET STRING
}
modlParamIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The module index.
The index can be the slot number or any other module index as described
in the specifications of the device.
For Vmux-2100 device, the index will have values of: 1..4 for slots 1..4."
::= { modlParamEntry 1 }
modlParamReset OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3),
factory (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Reset action to be performed on the module.
Set the parameter will be done always to on(3) or factory (4).
After performing the Reset operation, Agent will automatically set the parameter to off(2)."
::= { modlParamEntry 2 }
modlParamSwdlStatus OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
off (2),
inProcess (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whatever the swdl is in process or not."
::= {modlParamEntry 3}
modlParamLeds OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry specifies the LEDs status of the module.
Each led is represented by 4 bits where the first 2 bits (left) specify the status :
(00=NA, 01=OFF, 10=ON, 11=BLINK),
and the next two bits (right) specify the color :
(00=GREEN, 01=RED, 10=YELLOW, 11=GRAY).
The order of the LEDS is from top to bottom, left to right:
For each row starting from the top, the LEDS are returned from left to right."
::= {modlParamEntry 4}
agnNearFarConnection OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disconnected (2),
connected (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter describes the connection between near-end and far-end agents."
::= { agnt 33 }
agnAccess OBJECT IDENTIFIER ::= {agnt 34}
agnTelnetAccess OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3),
managersOnly (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable accessing the device via Telnet.
disable - no one will be allowed to access the device via Telnet.
enable - all users are allowed Telnet Access.
managersOnly - Only manager stations listed in the manager's list are allowed."
::= { agnAccess 1 }
agnWebAccess OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3),
managersOnly (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable accessing the device via Web.
disable - no one will be allowed to access the device via Web.
enable - all users are allowed Web Access.
managersOnly - Only manager stations listed in the manager's list are allowed."
::= { agnAccess 2 }
systemInterface OBJECT IDENTIFIER ::= { agnt 35 }
SysIfEntityType ::= INTEGER
-- STATUS current
-- DESCRIPTION
-- "This type defines the Entity Type.
-- The values existing in IANAifType MIB
-- should be taken from there only.
-- Additional values can be added, starting from 1000 decimal,
-- when necessary."
{
other(1),
ethernetLan(6),
atm(37),
fastEther(62), -- Fast Ethernet (100BaseT)
ipForward(142), -- Router
teLink(200),
bridge(209)
}
-- Interface Configuration Table
ifCreateTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfCreateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Interface Configuration Table.
This table enables to create inferfaces of Entities."
::= { systemInterface 1 }
ifCreateEntry OBJECT-TYPE
SYNTAX IfCreateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Interface Configuration table."
INDEX { ifCreateEntityType , ifCreateEntityIdx ,
ifCreateNumber }
::= { ifCreateTable 1 }
IfCreateEntry ::=
SEQUENCE {
ifCreateEntityType SysIfEntityType,
ifCreateEntityIdx Integer32,
ifCreateNumber Integer32,
ifCreateRowStatus RowStatus,
ifCreateType IANAifType,
ifCreateIndex Integer32
}
ifCreateEntityType OBJECT-TYPE
SYNTAX SysIfEntityType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Entity Type."
::= { ifCreateEntry 1 }
ifCreateEntityIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Entity Index."
::= { ifCreateEntry 2 }
ifCreateNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Interface Number."
::= { ifCreateEntry 3 }
ifCreateRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries in this table."
::= { ifCreateEntry 4 }
ifCreateType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Interface Type."
::= { ifCreateEntry 5 }
ifCreateIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the ifIndex of the created Interface."
::= { ifCreateEntry 6 }
systemOam OBJECT IDENTIFIER ::= { agnt 36 }
systemOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF SystemOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The OAM Configuration Table."
::= { systemOam 1 }
systemOamEntry OBJECT-TYPE
SYNTAX SystemOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the OAM table."
INDEX { systemOamCnfgIdx }
::= { systemOamTable 1 }
SystemOamEntry ::=
SEQUENCE {
systemOamCnfgIdx Integer32,
systemOamFrequency Integer32,
systemOamTimeoutCycles Integer32
}
systemOamCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { systemOamEntry 1}
systemOamFrequency OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time in sec. between 2 OAM packets."
::= { systemOamEntry 2 }
systemOamTimeoutCycles OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"No. of cycles the agent will send OAM packets without receiving a response
from the remote device before declaring that the connection to the remote side
is down - Time Out."
::= { systemOamEntry 3 }
bitMappingTable OBJECT-TYPE
SYNTAX SEQUENCE OF BitMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maps bits of an octet string to an interface.
For ACE-2002 this table is used to map bits of VLAN port lists
to LAN VCC's. This table is the opposite view of the xcTable for
xcBitMapping. It is used to ease the bit translation for the NMS."
::= { agnt 38 }
bitMappingEntry OBJECT-TYPE
SYNTAX BitMappingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in the table describes a correlation of a bit location to
an interface.
For ACE-2002 - Upon creation of a new LAN VCC the agent will add an
entry to this table that will define the bit location for that VCC."
INDEX { bitMappingLocation }
::= { bitMappingTable 1}
BitMappingEntry ::=
SEQUENCE {
bitMappingLocation Integer32,
bitMappingIndex Integer32
}
bitMappingLocation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bit location in an octet string."
::= { bitMappingEntry 1 }
bitMappingIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index or any other index that should be mapped."
::= { bitMappingEntry 2 }
bitMappingView OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A view of the bitMappingTable in one object - each entry in the
biMappingTable will have the corresponding Bit of this object
(bitMappingLocation) = '1'.
For ACE-2002 it is used to describe all the existing LAN VCC's
So that the NMS can easily calculate which VCC's can be selected
as members for a VLAN, instead of reading all the bitMapping Table."
::= { agnt 39 }
--TRAPS
--NOTIFICATIONS
systemsEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD products."
::= { systems 0 }
tftpStatusChangeTrap NOTIFICATION-TYPE
OBJECTS { tftpStatus }
STATUS current
DESCRIPTION
"This trap is sent whenever the status of tftp changed."
::= { systemsEvents 1 }
agnStatusChangeTrap NOTIFICATION-TYPE
OBJECTS {agnIndication }
STATUS current
DESCRIPTION
"This trap is sent whenever the state of the entity the agent is
responsible for changed.
TDM devices will send agnTestStatus variable to indicate the current test status."
::= { systemsEvents 2 }
prtStatusChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent whenever the state of a port changed.
Attached, will be parameter/s that indicate the new port status.
The attached variables will be specified in the specifications
of the products supporting this trap."
::= { systemsEvents 3 }
swdlStatusResult NOTIFICATION-TYPE
OBJECTS {swdlStatusFileName}
STATUS current
DESCRIPTION
"This notification is sent when Software Down Load is finished.
The attached object indicates the File Name."
::= { systemsEvents 4 }
intSwdlSlotFileMismatch NOTIFICATION-TYPE
OBJECTS {intSwdlFileName}
STATUS current
DESCRIPTION
"This notification is sent when the card in the chosen slot doesn't match
the chosen file.
The attached object indicates the File Name."
::= { systemsEvents 5 }
agnCounterChange NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This notification is sent when the value of a specific Counter is changed.
Agent can send as attached object the updated Counter.
For details about this Counter and attached object, see spec of the relevant
application."
::= { systemsEvents 6 }
prtClkSrcChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon any port clock change."
::= { systemsEvents 7 }
moduleFailTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon a module failure."
::= { systemsEvents 8 }
moduleInitFailTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon a module initialization failure."
::= { systemsEvents 9 }
clkSrcChangeTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon any change in Clock Source."
::= { systemsEvents 10 }
agnUploadDataTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon an upload data session termination.
For more details see product specification."
::= { systemsEvents 11 }
enrollmentTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is a periodically trap, which sent to manager
untill Agent get any response (Get or Set) from this manager."
::= { systemsEvents 12 }
agnPowerFailureTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"This trap is sent upon power failure. It is applicable for
the following devices:
1. Devices having one PS unit, which sense the failure in advance,
and still have time to send this trap before it goes off.
2. Devices having 2 PS units and send this trap in order to notify a
failure in one of the units."
::= { systemsEvents 13 }
--
-- file :v:\doc\rdv\mib\ver495\radds1.txt
--
-- RAD-DS1-MIB DEFINITIONS ::= BEGIN
--Title: RAD-DS1 MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- IMPORTS
-- PerfCurrentCount, PerfIntervalCount FROM PerfHist-TC-MIB;
-- OBJECT-TYPE FROM RFC-1212
-- radWan FROM RAD-GEN-MIB;
-- RAD-DS1 MIB
--Title: RAD's DS1 INTERFACE MIB
--Date: 03.02.98
--By: Ilana Schvetz
--File: radds1.mib
-- Last updated by Shlomo Shoham 20-Jan-2003
ds1Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 4}
prtDs1PerfHistory OBJECT IDENTIFIER ::= {ds1Interface 1}
-- Extension to the dsx1 current table
dsx1XCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1XCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of current statistics entries. This table
contains additional objects for the current table."
::= { prtDs1PerfHistory 2 }
dsx1XCurrentEntry OBJECT-TYPE
SYNTAX Dsx1XCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional statistical counters
applicable to a particular current table."
-- AUGMENTS { dsx1CurrentEntry }
INDEX { dsx1CurrentIndex }
::= { dsx1XCurrentTable 1 }
Dsx1XCurrentEntry ::=
SEQUENCE {
dsx1CurrentLOS PerfCurrentCount,
dsx1CurrentLOF PerfCurrentCount,
dsx1CurrentLOC PerfCurrentCount,
dsx1CurrentAIS PerfCurrentCount,
dsx1CurrentRAI PerfCurrentCount,
dsx1CurrentLOMF PerfCurrentCount,
dsx1CurrentFEBE PerfCurrentCount,
dsx1CurrentStatus OCTET STRING,
dsx1CurrentBPV PerfCurrentCount,
dsx1CurrentLOCRCMF PerfCurrentCount,
dsx1CurrentLOFC PerfCurrentCount,
dsx1CurrentCRCErrors PerfCurrentCount
}
dsx1CurrentLOS OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds, encountered by a DS1 interface in
the current 15 minute interval."
::= { dsx1XCurrentEntry 1 }
dsx1CurrentLOF OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a DS1
interface in the current 15 minute interval."
::= { dsx1XCurrentEntry 2 }
dsx1CurrentLOC OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver
lost cells delineation ."
::= { dsx1XCurrentEntry 3 }
dsx1CurrentAIS OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AIS
seconds, encountered by a DS1
interface in the current 15 minute interval."
::= { dsx1XCurrentEntry 4 }
dsx1CurrentRAI OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote Alarm Indication: Transmitted in the outgoing direction
(toward the PABX) over FDL bits when the DS1 device detected
an incoming Loss Of Frame. Received from the far end (PABX)
over FDL when it detects a Loss of frame."
::= { dsx1XCurrentEntry 5 }
dsx1CurrentLOMF OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of Multi-Frame sequence in E1 time slot 16."
::= { dsx1XCurrentEntry 6 }
dsx1CurrentFEBE OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Far End Block Errors, as reported in the first bit
of frames 13 and 15, on multiframe E1 lines with CRC4,
in the current 15 minute interval."
::= { dsx1XCurrentEntry 7 }
dsx1CurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { dsx1XCurrentEntry 8 }
dsx1CurrentBPV OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of BPVs (Bi-Polar Violations)
encountered by a DS1 interface in the current 15 minute interval."
::= { dsx1XCurrentEntry 9 }
dsx1CurrentLOCRCMF OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of CRC4 Multi-Frame sequence in E1.
encountered in the current 15 minute interval"
::= { dsx1XCurrentEntry 10 }
dsx1CurrentLOFC OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of loss of frame events measured.
encountered in the current 15 minute interval"
::= { dsx1XCurrentEntry 11 }
dsx1CurrentCRCErrors OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of CRC error events,
encountered in the current 15 minute interval."
::= { dsx1XCurrentEntry 12 }
-- Interval table
dsx1XIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1XIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A list of Interval entries. This table
contains additional objects for the interval table."
::= { prtDs1PerfHistory 3 }
dsx1XIntervalEntry OBJECT-TYPE
SYNTAX Dsx1XIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional statistical counters
applicable to a particular interval table."
-- AUGMENTS { dsx1IntervalEntry }
INDEX { dsx1IntervalIndex, dsx1IntervalNumber }
::= { dsx1XIntervalTable 1 }
Dsx1XIntervalEntry ::=
SEQUENCE {
dsx1IntervalLOS PerfIntervalCount,
dsx1IntervalLOF PerfIntervalCount,
dsx1IntervalLOC PerfIntervalCount,
dsx1IntervalAIS PerfIntervalCount,
dsx1IntervalRAI PerfIntervalCount,
dsx1IntervalLOMF PerfIntervalCount,
dsx1IntervalFEBE PerfIntervalCount,
dsx1IntervalStatus OCTET STRING,
dsx1IntervalBPV PerfIntervalCount,
dsx1IntervalLOCRCMF PerfIntervalCount,
dsx1IntervalLOFC PerfIntervalCount
}
dsx1IntervalLOS OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds , encountered by a DS1 interface in
one of the previous 96, individual 15 minute,
intervals."
::= { dsx1XIntervalEntry 1 }
dsx1IntervalLOF OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of OOF
seconds, encountered by a DS1
interface in one of the previous 96, individual 15
minute, intervals."
::= { dsx1XIntervalEntry 2 }
dsx1IntervalLOC OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Loss Of Cell delineation. Counts number of cells the ATM UNI cells receiver
lost cells delineation ."
::= { dsx1XIntervalEntry 3 }
dsx1IntervalAIS OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AIS
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { dsx1XIntervalEntry 4 }
dsx1IntervalRAI OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remote Alarm Indication: Transmitted in the outgoing direction
(toward the PABX) over FDL bits when the DS1 device detected
an incoming Loss Of Frame. Received from the far end (PABX)
over FDL when it detects a Loss of frame."
::= { dsx1XIntervalEntry 5 }
dsx1IntervalLOMF OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of Multi-Frame sequence in E1 time slot 16."
::= { dsx1XIntervalEntry 6 }
dsx1IntervalFEBE OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Far End Block Errors, as reported in the first bit
of frames 13 and 15, on multiframe E1 lines with CRC4,
in one of the previous 96, individual, 15 minute intervals."
::= { dsx1XIntervalEntry 7 }
dsx1IntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { dsx1XIntervalEntry 8 }
dsx1IntervalBPV OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of BPV (Bi-Polar Violations)
encountered by a DS1 interface in one of the previous 96,
individual 15 minute, intervals."
::= { dsx1XIntervalEntry 9 }
dsx1IntervalLOCRCMF OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Loss of CRC4 Multi-Frame sequence in E1."
::= { dsx1XIntervalEntry 10 }
dsx1IntervalLOFC OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Counts the number of loss of frame events measured
in one of the previous 96, individual 15 minute, intervals."
::= { dsx1XIntervalEntry 11 }
-- Extension to the dsx1 Total table
dsx1XTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1XTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of Total statistics entries. This table
contains additional objects for the Total table."
::= { prtDs1PerfHistory 4 }
dsx1XTotalEntry OBJECT-TYPE
SYNTAX Dsx1XTotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional statistical counters
applicable to a particular current table."
-- AUGMENTS { dsx1CurrentEntry }
INDEX { dsx1TotalIndex }
::= { dsx1XTotalTable 1 }
Dsx1XTotalEntry ::=
SEQUENCE {
dsx1TotalBPV PerfTotalCount,
dsx1TotalLOFC PerfTotalCount
}
dsx1TotalBPV OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of BPV (Bi-Polar Violations)
encountered by a DS1 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1XTotalEntry 9 }
dsx1TotalLOFC OBJECT-TYPE
SYNTAX PerfTotalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number loss of frames
encountered by a DS1 interface in the previous 24 hour interval.
Invalid 15 minute intervals count as 0."
::= { dsx1XTotalEntry 11 }
-- Extension to the DS1 Configuration Table
dsx1XConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dsx1XConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An extension to the DS1 Configuration table."
::= { ds1Interface 2 }
dsx1XConfigEntry OBJECT-TYPE
SYNTAX Dsx1XConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry containing additional configuration
parameters."
-- AUGMENTS { dsx1ConfigTable }
INDEX { dsx1LineIndex }
::= { dsx1XConfigTable 1 }
Dsx1XConfigEntry ::=
SEQUENCE {
dsx1IdleCode Integer32,
dsx1LineMode INTEGER,
dsx1dBTxGain INTEGER,
dsx1RxSensitivity INTEGER,
dsx1RestoreTime INTEGER,
dsx1TcFirstSignal Integer32,
dsx1TcSignal Integer32,
dsx1TcPattern Integer32,
dsx1Scramble INTEGER,
dsx1LineAdaptiveTimingMode INTEGER,
dsx1TxClockSource INTEGER,
dsx1AisEnable INTEGER,
dsx1TsEchoCancel OCTET STRING,
dsx1EchoCancelerModule INTEGER,
dsx1PortFunction INTEGER,
dsx1PortMultiplier INTEGER,
dsx1LeasedLine INTEGER,
dsx1CsuLoop INTEGER
}
dsx1IdleCode OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Byte pattern of the data received/transmitted in the
E1T1 framer idle timeslots.
Valid range: (0 - FF HEX)."
::= { dsx1XConfigEntry 1 }
dsx1LineMode OBJECT-TYPE
SYNTAX INTEGER {
csu(1),
dsu(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"T1 device operation mode.
Valid for T1 only."
::= { dsx1XConfigEntry 2 }
dsx1dBTxGain OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
neg75dB (2),
neg15dB (3),
neg225dB (4),
zerodB (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Transmit line Gain for T1 CSU line mode."
::= { dsx1XConfigEntry 3 }
dsx1RxSensitivity OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
neg10dB (2),
neg32dB (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determine the maximum attenuation of the
receive signal that can be compensated for
by the interface receive path. Not applicable for T1."
::= { dsx1XConfigEntry 4 }
dsx1RestoreTime OBJECT-TYPE
SYNTAX INTEGER {
other(1),
sec1(2),
sec10(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to change the sync. algorithms to reduce the time
required for the port to return to normal operation after
a RED alarm."
::= { dsx1XConfigEntry 5 }
dsx1TcFirstSignal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk conditioning signal - value to be sent as a signal
during the first 2.5 seconds after alarm detection.
Range is 0x0..0xF. 0xFF is a NULL value. Valid for T1 only."
::= { dsx1XConfigEntry 6 }
dsx1TcSignal OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk conditioning signal value after alarm detection.
Range is 0x1..0xF for E1, and 0x0..0xF for T1."
::= { dsx1XConfigEntry 7 }
dsx1TcPattern OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Trunk conditioning data pattern to be sent upon a DS0 fail.
Range is 0x0..0xFF."
::= { dsx1XConfigEntry 8 }
dsx1Scramble OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
notActive (2),
active (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Scrambling is an operation that randomizes the bits
of the payload of the ATM cell by a polynom.
This operation helps with the error detection mechanism
of the HEC. Not applicable for E1.
active - will scramble/descramble the payload ATM cell
notActive - will not scramble/descramble. "
::= { dsx1XConfigEntry 9 }
dsx1LineAdaptiveTimingMode OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables end to end clock synchronization.
Default value - off."
::= { dsx1XConfigEntry 10 }
dsx1TxClockSource OBJECT-TYPE
SYNTAX INTEGER {
loopTiming(1),
localTiming(2),
throughTiming(3),
adaptive(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of Transmit Clock.
'loopTiming' indicates that the recovered receive clock
is used as the transmit clock.
'localTiming' indicates that a local clock
source is used or when an external clock is
attached to the box containing the interface.
'throughTiming' indicates that recovered receive clock
from another interface is used as the transmit clock.
'adaptive' indicates that the clock is recovered according
to the received data flow rate. "
::= { dsx1XConfigEntry 11 }
dsx1AisEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable(2),
enable(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/ disable AIS transmit when Ethernet cable (for TDMoIP) is out (disconnected)."
::= { dsx1XConfigEntry 12 }
dsx1TsEchoCancel OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines for each TS whether Echo-Cancellation is on.
Each bit represents one TS as follow:
First octet bit'0' = TS#1, bit'7' = TS#8, .. 2nd octet bit'0' = TS#9,..,
4th octet bit'7' = TS#32.
Octets and bits order is from left to right:
[31,30,..24] [23..16] [15..8] [7..0]
MSB LSB MSB LSB MSB LSB MSB LSB
For each bit values are:
0 - Echo-Cancellation off.
1 - Echo-Cancellation on."
::= { dsx1XConfigEntry 13 }
dsx1EchoCancelerModule OBJECT-TYPE
SYNTAX INTEGER {
notExist(2),
exist(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates whether echo-cancellation module
exists for this line."
::= { dsx1XConfigEntry 14 }
dsx1PortFunction OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
uni (2),
ces (3),
ima (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the ATM Mode over the
physical port.
uni - The port will function as an ATM UNI.
ces - The port will function as a CES.
ima - The port will function as an IMA-ATM."
::= { dsx1XConfigEntry 15 }
dsx1PortMultiplier OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
r56 (2),
r64 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object determines the data rate of each TS
(Kbps units).
This parameter is applicable for T1 only."
::= { dsx1XConfigEntry 16 }
dsx1LeasedLine OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether Line mode is regular (non Leased Line mode)
or transparent (Leased Line mode)."
::= { dsx1XConfigEntry 17 }
dsx1CsuLoop OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
local (2),
transparent (3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether CSU loop will be done locally (by IPmux)
or will be transferred to the TDM device."
::= { dsx1XConfigEntry 18 }
-- END
--
-- file :v:\doc\rdv\mib\Before~1\radds3.txt
--
-- RAD-DS3-MIB DEFINITIONS ::= BEGIN
--Title: RAD-DS3 MIB
--
-- Copyright 1993 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- It is RAD's intent to encourage the widespread use of
-- this Specification in connection with the management of
-- RAD products. RAD grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of RAD products.
-- This Specification is supplied "as is," and RAD makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.
-- IMPORTS
-- Gauge32 FROM SNMPv2-SMI
-- ifIndex FROM SNMPv2-TC
-- OBJECT-TYPE FROM SNMPv2-SMI
-- radWan FROM RAD-GEN-MIB;
-- RAD-DS3 MIB
--Title: RAD's DS3 INTERFACE MIB
--Version: 1.0
--Date: 13.10.96
--By: Yair Arian
--File: ds3.mib
--
--Last update: 27.01.98 by Ilana
ds3Interface OBJECT IDENTIFIER ::= {diverseIfWanGen 3}
prtDs3PerfHistory OBJECT IDENTIFIER ::= {ds3Interface 1}
-- The DS3 Interface Table
prtSDs3IfTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDs3IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 interface table."
::= { prtDs3PerfHistory 1 }
prtDs3IfEntry OBJECT-TYPE
SYNTAX PrtDs3IfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 interface table."
INDEX { ifIndex }
::= { prtSDs3IfTable 1 }
PrtDs3IfEntry ::=
SEQUENCE {
prtDs3IfTimeElapsed
Integer32,
prtDs3IfValidIntervals
Integer32
}
prtDs3IfTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the near end current error-
measurement period."
::= { prtDs3IfEntry 1 }
prtDs3IfValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous near end intervals for
which valid data was collected. The value will be
96 unless the interface was brought online within
the last 24 hours, in which case the value will be
the number of complete 15 minute near end
intervals since the interface has been online."
::= { prtDs3IfEntry 2 }
-- The DS3 Current Table
-- The DS3 Current table contains various statistics being
-- collected for the current 15 minute interval.
prtDs3CurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDs3CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 Current table."
::= { prtDs3PerfHistory 2 }
prtDs3CurrentEntry OBJECT-TYPE
SYNTAX PrtDs3CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 Current table."
INDEX { ifIndex }
::= { prtDs3CurrentTable 1 }
PrtDs3CurrentEntry ::=
SEQUENCE {
prtDs3CurrentLOS
Gauge32,
prtDs3CurrentOOF
Gauge32,
prtDs3CurrentLOC
Gauge32,
prtDs3CurrentAIS
Gauge32,
prtDs3CurrentRDI
Gauge32,
prtDs3CurrentUAS
Gauge32,
prtDs3CurrentBIP
Gauge32,
prtDs3CurrentFEBE
Gauge32,
prtDs3CurrentSLM
Gauge32,
prtDs3CurrentSES
Gauge32,
prtDs3CurrentES
Gauge32,
prtDs3CurrentBitParity
Gauge32,
prtDs3CurrentPlcpLOF
Gauge32,
prtDs3CurrentPlcpRAI
Gauge32,
prtDs3CurrentPlcpBIP
Gauge32,
prtDs3CurrentPlcpFEBE
Gauge32,
prtDs3CurrentBPV
Gauge32,
prtDs3CurrentLCE
Gauge32,
prtDs3CurrentStatus
OCTET STRING
}
prtDs3CurrentLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds, encountered by a DS3 interface in
the current 15 minute interval."
::= { prtDs3CurrentEntry 1 }
prtDs3CurrentOOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of OOF
seconds, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 2 }
prtDs3CurrentLOC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOC
seconds, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 3 }
prtDs3CurrentAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AIS
seconds, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 4 }
prtDs3CurrentRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of RDI
seconds, encountered by a DS3
interface."
::= { prtDs3CurrentEntry 5 }
prtDs3CurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS,
encountered by a SONET interface."
::= { prtDs3CurrentEntry 6 }
prtDs3CurrentBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
BIP errors, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 7 }
prtDs3CurrentFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
FEBE errors, encountered by a DS3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 8 }
prtDs3CurrentSLM OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SLM
seconds, encountered by an E3 (only )
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 9 }
prtDs3CurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a E3
interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 10 }
prtDs3CurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of Errored Seconds, encountered by a
DS3 interface in the current 15 minute interval."
::= { prtDs3CurrentEntry 11 }
prtDs3CurrentBitParity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Parity Error counter. Relevant to T3 only."
::= { prtDs3CurrentEntry 12 }
prtDs3CurrentPlcpLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals. This counter is relevant for plcpInternal(5)
or plcpExternal(6) configuration If frame types only."
::= { prtDs3CurrentEntry 13 }
prtDs3CurrentPlcpRAI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receiving Yellow/Remote Alarm Indication. This counter is
relevant for PLCP (external/internal) frame types only."
::= { prtDs3CurrentEntry 14 }
prtDs3CurrentPlcpBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The counter associated with the number of BIP errors,
encountered by a DS3 interface in the current 15 minute
interval. This counter is relevant for PLCP (external/internal)
frame types only."
::= { prtDs3CurrentEntry 15 }
prtDs3CurrentPlcpFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The counter associated with the number of FEBE
errors, encountered by a DS3 interface in the current
15 minute interval. This counter is relevant for PLCP
(external/internal) frame types only."
::= { prtDs3CurrentEntry 16 }
prtDs3CurrentBPV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of BPVs (Bi-Polar Violations) , encountered by a
DS3 interface in the current 15 minute interval.
This object is relevant only for Electrical Line
of Fomi-E3/T3."
::= { prtDs3CurrentEntry 17 }
prtDs3CurrentLCE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of LCE (Link Code Errors) encountered
by a DS3 interface in the current 15 minute interval.
This object is relevant only for Optical Links
of Fomi-E3/T3."
::= { prtDs3CurrentEntry 18 }
prtDs3CurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { prtDs3CurrentEntry 19 }
-- The DS3 interface Interval
-- The DS3 Interval Table contains various statistics
-- collected by the Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
prtDs3IntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDs3IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The DS3 Interval table."
::= { prtDs3PerfHistory 3 }
prtDs3IntervalEntry OBJECT-TYPE
SYNTAX PrtDs3IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the DS3 Interval table."
INDEX { ifIndex, prtDs3IntervalNumber }
::= { prtDs3IntervalTable 1 }
PrtDs3IntervalEntry ::=
SEQUENCE {
prtDs3IntervalNumber
Integer32,
prtDs3IntervalLOS
Gauge32,
prtDs3IntervalOOF
Gauge32,
prtDs3IntervalLOC
Gauge32,
prtDs3IntervalAIS
Gauge32,
prtDs3IntervalRDI
Gauge32,
prtDs3IntervalUAS
Gauge32,
prtDs3IntervalBIP
Gauge32,
prtDs3IntervalFEBE
Gauge32,
prtDs3IntervalSLM
Gauge32,
prtDs3IntervalSES
Gauge32,
prtDs3IntervalES
Gauge32,
prtDs3IntervalBitParity
Gauge32,
prtDs3IntervalPlcpLOF
Gauge32,
prtDs3IntervalPlcpRAI
Gauge32,
prtDs3IntervalPlcpBIP
Gauge32,
prtDs3IntervalPlcpFEBE
Gauge32,
prtDs3IntervalBPV
Gauge32,
prtDs3IntervalLCE
Gauge32,
prtDs3IntervalStatus
OCTET STRING
}
prtDs3IntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { prtDs3IntervalEntry 1 }
prtDs3IntervalLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds , encountered by a DS3 interface in
one of the previous 96, individual 15 minute,
intervals."
::= { prtDs3IntervalEntry 2 }
prtDs3IntervalOOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of OOF
seconds, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 3 }
prtDs3IntervalLOC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOC
seconds, encountered by a DS3
interface in one of the previous 96,
individual 15 minute, intervals."
::= { prtDs3IntervalEntry 4 }
prtDs3IntervalAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AIS
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 5 }
prtDs3IntervalRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of RDI
seconds, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 6 }
prtDs3IntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS,
encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 7 }
prtDs3IntervalBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
BIP errors, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 8 }
prtDs3IntervalFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
FEBE errors, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 9 }
prtDs3IntervalSLM OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SLM
seconds, encountered by an E3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 10 }
prtDs3IntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a E3
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 11 }
prtDs3IntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The number of Errored Seconds, encountered by a
DS3 interface in one of the previous 96, individual 15
minute, intervals."
::= { prtDs3IntervalEntry 12 }
prtDs3IntervalBitParity OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Bit Parity Error counter. Relevant to T3 only."
::= { prtDs3IntervalEntry 13 }
prtDs3IntervalPlcpLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a DS3
interface in one of the previous 96, individual 15
minute, intervals. This counter is relevant for plcpInternal(5)
or plcpExternal(6) configuration If frame types only."
::= { prtDs3IntervalEntry 14 }
prtDs3IntervalPlcpRAI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Receiving Yellow/Remote Alarm Indication. This counter is
relevant for PLCP (external/internal) frame types only."
::= { prtDs3IntervalEntry 15 }
prtDs3IntervalPlcpBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The counter associated with the number of BIP errors,
encountered by a DS3 interface in the current 15 minute
interval. This counter is relevant for PLCP (external/internal)
frame types only."
::= { prtDs3IntervalEntry 16 }
prtDs3IntervalPlcpFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The counter associated with the number of FEBE
errors, encountered by a DS3 interface in the current
15 minute interval. This counter is relevant for PLCP
(external/internal) frame types only."
::= { prtDs3IntervalEntry 17 }
prtDs3IntervalBPV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of BPVs (Bi-Polar Violations) , encountered by a
DS3 interface in the specified 15 minute interval.
This object is relevant only for Electrical Line
of Fomi-E3/T3."
::= { prtDs3IntervalEntry 18 }
prtDs3IntervalLCE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Number of LCE (Link Code Errors) encountered
by a DS3 interface in the specified 15 minute interval.
This object is relevant only for Optical Links
of Fomi-E3/T3."
::= { prtDs3IntervalEntry 19 }
prtDs3IntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { prtDs3IntervalEntry 20 }
-- the DS3 Total table
prtDs3TotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtDs3TotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" A list of Total entries."
::= { prtDs3PerfHistory 4 }
prtDs3TotalEntry OBJECT-TYPE
SYNTAX PrtDs3TotalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry of Total table."
INDEX { ifIndex }
::= { prtDs3TotalTable 1 }
PrtDs3TotalEntry ::=
SEQUENCE {
prtDs3TotalUAS Gauge32,
prtDs3TotalBPV Gauge32,
prtDs3TotalLCE Gauge32
}
prtDs3TotalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of UASs (Unavailable Seconds) , encountered by a
DS3 interface in the previous 96 intervals.
Invalid 15 minute intervals count as 0."
::= { prtDs3TotalEntry 6 }
prtDs3TotalBPV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of BPVs (Bi-Polar Violations) , encountered by a
DS3 interface in the previous 96 intervals.
Invalid 15 minute intervals count as 0."
::= { prtDs3TotalEntry 17 }
prtDs3TotalLCE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of LCE (Link Code Errors) encountered
by a DS3 interface in the previous 96 intervals.
Invalid 15 minute intervals count as 0."
::= { prtDs3TotalEntry 18 }
-- END
--
-- file :v:\doc\rdv\mib\ver495\brggen.txt
--
--Version 4.95
--Initial Version: 4.0
--Date: 16.10.94
--By: Debby Koren & Orly Nicklass
--File: BRGgen.txt
--Last Updated by Ilana Schvetz 15-Jan-2003.
genBridge OBJECT IDENTIFIER ::= {radBridges 1 }
-- At the end of the MIB there is a definition of all RAD general traps for bridges.
radBridgeAction OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
sendNetworkTab(2),
deleteNetworkTab(3),
sendRoutingTab(4), -- Level II
deleteRoutinTab(5),
sendLanTab(6),
deleteLanTab(7),
deleteArpTab(8),
sendArpTab(9),
deleteRouteTab(10), -- Level III
sendRouteTab(11),
deactivateAllMasks(12),
saveAllActiveMasks(13),
loadAndActivateAllMasksFromNVRAM(14),
clearAllMasksFromNVRAM(15),
defaultConfig(16),
resetNVRAM(17),
clearIPNVRAM(18),
noOp(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable enables the operator to perform one of the
specified actions on the tables maintained by the network device.
Send actions are not currently implemented. Not all actions can
be performed on all bridges."
::= { genBridge 1 }
radBridgeInactiveArpTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the maximum time period that can pass
between ARP requests concerning an entry in the ARP table.
After this time period, the entry is deleted from the table."
::= { genBridge 2 }
-- radBridgeMaskTab defines the format of RAD Bridge OLD masking tables
radBridgeMaskTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeMaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Mask tables enable definition of forwarding restrictions and
control of message flow in the internetwork. Each entry
in this table defines a mask statement consisting of up to
three mask definitions and an action defined by
radBridgeMaskOper. Different types of mask entries are supported,
as defined by radBridgeMaskType."
::= { genBridge 3 }
radBridgeMaskEntry OBJECT-TYPE
SYNTAX RadBridgeMaskEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table radBridgeMaskTable."
INDEX { radBridgeMaskType, radBridgeMaskIfIndex, radBridgeMaskNum }
::= { radBridgeMaskTable 1 }
RadBridgeMaskEntry ::= SEQUENCE {
radBridgeMaskType
INTEGER,
radBridgeMaskIfIndex
Integer32,
radBridgeMaskNum
Integer32,
radBridgeMaskDest
INTEGER,
radBridgeMaskPat1
OCTET STRING,
radBridgeMaskActiveBit1
OCTET STRING,
radBridgeMaskFrom1
INTEGER,
radBridgeMaskOffset1
Integer32,
radBridgeMaskCond1
INTEGER,
radBridgeMaskPat2
OCTET STRING,
radBridgeMaskActiveBit2
OCTET STRING,
radBridgeMaskFrom2
INTEGER,
radBridgeMaskOffset2
Integer32,
radBridgeMaskCond2
INTEGER,
radBridgeMaskPat3
OCTET STRING,
radBridgeMaskActiveBit3
OCTET STRING,
radBridgeMaskFrom3
INTEGER,
radBridgeMaskOffset3
Integer32,
radBridgeMaskCond3
INTEGER,
radBridgeMaskOper
INTEGER
}
radBridgeMaskType OBJECT-TYPE
SYNTAX INTEGER {
tx(1),
rx(2),
compress(3),
priority(4),
loadSharing(5),
facs(6),
codConnect(7),
codDisconnect(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the type of mask entry."
::= { radBridgeMaskEntry 1 }
radBridgeMaskIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the if Index of the interface to which the mask is applied."
::= { radBridgeMaskEntry 2 }
radBridgeMaskNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Mask entry number, defined by its line number in the mask
table."
::= { radBridgeMaskEntry 3 }
radBridgeMaskDest OBJECT-TYPE
SYNTAX INTEGER {
unassigned-cond (1),
broadcast-msge (2),
multicast-msge (3),
all-msge(4),
none(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the type of destination address carried by the frame
to which the mask will be applied. Unassigned-condition
deactivates the mask entry."
::= { radBridgeMaskEntry 4 }
radBridgeMaskPat1 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes the mask field which is either a 16 bit binary pattern,
or four digit hexadecimal pattern."
::= { radBridgeMaskEntry 5 }
radBridgeMaskActiveBit1 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the positions of the wild card characters (*)
in the radBridgeMaskPat1 field."
::= { radBridgeMaskEntry 6 }
radBridgeMaskFrom1 OBJECT-TYPE
SYNTAX INTEGER {
mac(1),
llc(2),
net(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Offset base of radBridgeMaskPat1 within the frame.
Net can be in some cases the data start point."
::= { radBridgeMaskEntry 7 }
radBridgeMaskOffset1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the radBridgeMaskPat1 offset within the frame (in bytes) from
the base defined in by radBridgeMaskForm1.The mask offset is an even
decimal number in the range of 0 to 1518."
::= { radBridgeMaskEntry 8 }
radBridgeMaskCond1 OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
radBridgeMaskOffset1 the packet contains data that matches
the content of radBridgeMaskPat1.
false - Condition is valid if at the position specified by
radBridgeMaskOffset1 the packet contains data that does not
match the content of radBridgeMaskPat1."
::= { radBridgeMaskEntry 9 }
radBridgeMaskPat2 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes the mask field which is either a 16 bit binary pattern,
or four digit hexadecimal pattern."
::= { radBridgeMaskEntry 10 }
radBridgeMaskActiveBit2 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the positions of the wild card characters (*)
in the radBridgeMaskPat2 field."
::= { radBridgeMaskEntry 11 }
radBridgeMaskFrom2 OBJECT-TYPE
SYNTAX INTEGER {
mac (1),
llc (2),
net(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Offset base of radBridgeMaskPat2 within the frame.
Net can be in some cases the data start point."
::= { radBridgeMaskEntry 12 }
radBridgeMaskOffset2 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the radBridgeMaskPat2 offset within the frame (in bytes) from
the base defined in by radBridgeMaskForm2.The mask offset is an even
decimal number in the range of 0 to 1518."
::= { radBridgeMaskEntry 13 }
radBridgeMaskCond2 OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
radBridgeMaskOffset2 the packet contains data that matches
the content of radBridgeMaskPat2.
false - Condition is valid if at the position specified by
radBridgeMaskOffset2 the packet contains data that does not
match the content of radBridgeMaskPat2."
::= { radBridgeMaskEntry 14 }
radBridgeMaskPat3 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Describes the mask field which is either a 16 bit binary pattern,
or four digit hexadecimal pattern."
::= { radBridgeMaskEntry 15 }
radBridgeMaskActiveBit3 OBJECT-TYPE
SYNTAX OCTET STRING -- (SIZE (2))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the positions of the wild card characters (*)
in the radBridgeMaskPat3 field."
::= { radBridgeMaskEntry 16 }
radBridgeMaskFrom3 OBJECT-TYPE
SYNTAX INTEGER {
mac (1),
llc (2),
net (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Offset base of radBridgeMaskPat3 within the frame.
Net can be in some cases the data start point."
::= { radBridgeMaskEntry 17 }
radBridgeMaskOffset3 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the radBridgeMaskPat3 offset within the frame (in bytes) from
the base defined in by radBridgeMaskForm3. The mask offset is an even
decimal number in the range of 0 to 1518."
::= { radBridgeMaskEntry 18 }
radBridgeMaskCond3 OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
radBridgeMaskOffset3 the packet contains data that matches
the content of radBridgeMaskPat3
false - Condition is valid if at the position specified by
radBridgeMaskOffset3 the packet contains data that does not
match the content of radBridgeMaskPat3."
::= { radBridgeMaskEntry 19 }
radBridgeMaskOper OBJECT-TYPE
SYNTAX INTEGER {
block (1),
forward (2),
route (3),
forward-route (4),
high-priority (5),
noOp(6),
delete(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of action to be taken if the frame meets the
conditions of the mask.
noOp = disabled (mask remains on list, but is not active)
delete = mask is removed from the list. "
::= { radBridgeMaskEntry 20 }
radBridgeCOD OBJECT IDENTIFIER ::= {genBridge 4 }
radBridgeCODParamTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCODEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of COD parameters "
::= { radBridgeCOD 1}
radBridgeCODEntry OBJECT-TYPE
SYNTAX RadBridgeCODEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each radBridgeCODEntry consists of the following parameters"
INDEX {radBridgeCODIfIndex}
::= { radBridgeCODParamTable 1 }
RadBridgeCODEntry ::= SEQUENCE {
radBridgeCODIfIndex
Integer32,
radBridgeCODManualConnect
INTEGER,
radBridgeCODMode
INTEGER,
radBridgeCODConnectDelay
Integer32,
radBridgeCODisConnectDelay
Integer32,
radBridgeCODImplicitSwitch
INTEGER,
radBridgeCODNumAccess
Counter32,
radBridgeCODTotalConnecTime
Integer32
}
radBridgeCODIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface to which this COD entry is applicable."
::= { radBridgeCODEntry 1 }
radBridgeCODManualConnect OBJECT-TYPE
SYNTAX INTEGER {
connect(1),
disconnect(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The management station can start connection manually
by setting this parameter"
::= { radBridgeCODEntry 2 }
radBridgeCODMode OBJECT-TYPE
SYNTAX INTEGER {
answer(1),
originate(2),
disable(3),
answerAndOriginate(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In answer mode only one incoming call may be accepted at a time. Other nodes
attempting to access the local modem will receive a busy signal until the
connection is terminated. (Answer mode has no difficulty supporting multiple
remote connections to one local port, as blocking multiple incoming calls is
just a modem function. Originate mode, on the other
hand will only support a single local port to remote port connection).
The disable parameter disables the COD utility for this interface.
Choosing any other mode will enable the COD utility."
::= { radBridgeCODEntry 3 }
radBridgeCODConnectDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The connect delay defines the minimum time period that
the link must stay disconnected, between 2 succesive
connections (in seconds)."
::= { radBridgeCODEntry 4 }
radBridgeCODisConnectDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The disconnect delay defines the minimum time period
the link must stay connected, between 2 succesive
disconnections (in seconds)."
::= { radBridgeCODEntry 5 }
radBridgeCODImplicitSwitch OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The inplicit switch allows the user to ignore implicit triggers provided
by the COD software."
-- DEFVAL { 1 }
::= { radBridgeCODEntry 6 }
radBridgeCODNumAccess OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of successful connections that have been established since
the COD has been reset."
::= { radBridgeCODEntry 7}
radBridgeCODTotalConnecTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The sum of all the connect time intervals since the COD was reset."
::= { radBridgeCODEntry 8}
radBridgeCODTimeTriggerTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCODTimeTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of COD parameters "
::= { radBridgeCOD 2 }
radBridgeCODTimeTriggerEntry OBJECT-TYPE
SYNTAX RadBridgeCODTimeTriggerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each radBridgeCODTimeTriggerEntry consists of the following parameters"
INDEX { radBridgeCODTimeIfIndex, radBridgeCODDay, radBridgeCODTimeTriggerNum }
::= { radBridgeCODTimeTriggerTable 1 }
RadBridgeCODTimeTriggerEntry ::= SEQUENCE {
radBridgeCODTimeIfIndex
Integer32,
radBridgeCODDay
INTEGER,
radBridgeCODTimeTriggerNum
Integer32,
radBridgeCODTimeTriggerFrom
DisplayString,
radBridgeCODTimeTriggerTo
DisplayString,
radBridgeCODTimeTriggerStatus
INTEGER
}
radBridgeCODTimeIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface to which this COD Time Trigger entry is applicable."
::= { radBridgeCODTimeTriggerEntry 1}
radBridgeCODDay OBJECT-TYPE
SYNTAX INTEGER {
mon(1),
tue(2),
wed(3),
thu(4),
fri(5),
sat(6),
sun(7)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The day of the week in which the dial up connection operates."
::= { radBridgeCODTimeTriggerEntry 2 }
radBridgeCODTimeTriggerNum OBJECT-TYPE
SYNTAX Integer32 (1..3)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Every day of the week the user can configure 3 dial up connections."
::= { radBridgeCODTimeTriggerEntry 3 }
radBridgeCODTimeTriggerFrom OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to start Dial Up connection, in format hh:mm."
::= {radBridgeCODTimeTriggerEntry 4 }
radBridgeCODTimeTriggerTo OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to terminate Dial Up connection, in format HH:MM."
::= {radBridgeCODTimeTriggerEntry 5 }
radBridgeCODTimeTriggerStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of a table entry."
::= { radBridgeCODTimeTriggerEntry 6 }
radBridgeCODTraffic OBJECT IDENTIFIER ::= { radBridgeCOD 3}
radBridgeCODTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCODTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of COD Traffic trigger "
::= { radBridgeCODTraffic 1 }
radBridgeCODTrafficEntry OBJECT-TYPE
SYNTAX RadBridgeCODTrafficEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each radBridgeCODTrafficEntry consists of the following parameters."
INDEX {radBridgeCODProtocolType}
::= { radBridgeCODTrafficTable 1}
RadBridgeCODTrafficEntry ::= SEQUENCE {
radBridgeCODProtocolType
INTEGER,
radBridgeCODTrafficTriggerStatus
INTEGER }
radBridgeCODProtocolType OBJECT-TYPE
SYNTAX INTEGER {
ip(1),
ipx(2),
other(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Protocol Type of the Traffic Table"
::= { radBridgeCODTrafficEntry 1 }
radBridgeCODTrafficTriggerStatus OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command of Status of the Protocol Traffic Trigger"
::= { radBridgeCODTrafficEntry 2 }
radBridgeCODRemoteIPAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This is the Remote IP Address"
::= { radBridgeCODTraffic 2 }
radBridgeCODIPMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This is the Mask of the Remote IP Address"
::= { radBridgeCODTraffic 3 }
radBridgeCODTrafficTriggerProtType OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protocol Type for the User Defined Protocol Traffic Trigger (3)."
::= { radBridgeCODTraffic 4 }
--COD Condition table
radBridgeCODCondTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCODCondEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of COD Condition parameters "
::= { radBridgeCOD 4}
radBridgeCODCondEntry OBJECT-TYPE
SYNTAX RadBridgeCODCondEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each radBridgeCODCondEntry consists of the following parameters"
INDEX {radBridgeCODCondIfIndex}
::= { radBridgeCODCondTable 1 }
RadBridgeCODCondEntry ::= SEQUENCE {
radBridgeCODCondIfIndex
Integer32,
radBridgeCODOriginateConnectCondition
INTEGER,
radBridgeCODOriginateDisConnectCondition
INTEGER,
radBridgeCODOriginateDisConnectDelay
Integer32,
radBridgeCODAnswerConnectCondition
INTEGER,
radBridgeCODSpecificOnTrafficOIDCondition
OBJECT IDENTIFIER,
radBridgeCODDisConnectMinimunFramesNumber
Integer32
}
radBridgeCODCondIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface, this COD entry is applicable to."
::= { radBridgeCODCondEntry 1 }
radBridgeCODOriginateConnectCondition OBJECT-TYPE
SYNTAX INTEGER {
onPowerOn (1),
whenAnyStationOnLan (2),
onTraffic (3),
onManualConnect (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This condition, allows the user to specify the
condition under which the link is connected.
The options are
onPowerOn - On power on.
whenAnyStationOnLan - When any station on lan.
onTraffic - On traffic. The user can specify the
condition/s for connection.
The connection will be defined in
CODSpecificOnTrafficConditionOID .
onManualConnect - depends on radBridgeCODManualConnect
OBJECT-TYPE (=connect).
"
::= { radBridgeCODCondEntry 2 }
radBridgeCODOriginateDisConnectCondition OBJECT-TYPE
SYNTAX INTEGER {
noStationOnLan (1),
onTraffic (2),
onDelayFromConnectionOnRequest (3),
onManualDisConnect (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This condition allows the user to specify the
condition under which the link is disconnected.
The options are:
noStationOnLan - When there is no station on lan.
Counts 15 minutes from the point the last
frame from lan has been received. If no
frame have been transmitted on lan by the
end of this period, disconnect the connection.
onTraffic - On traffic. The user can specify the
condition/s for disconnection.
The disconnection will be defined in
CODSpecificOnTrafficConditionOID .
onDelayFromConnectionOnRequest -
On Delay From Connection On Request .
The delay time period will be defined in
CODOriginateDisConnectDelay .
onManualDisConnect - depends on radBridgeCODManualConnect
OBJECT-TYPE (=disconnect).
"
::= { radBridgeCODCondEntry 3 }
radBridgeCODOriginateDisConnectDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Delay time in seconds. "
::= { radBridgeCODCondEntry 4 }
radBridgeCODAnswerConnectCondition OBJECT-TYPE
SYNTAX INTEGER {
onPowerOn (1),
whenAnyStationOnLan (2),
onTraffic (3),
onManualConnect (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CODCondAnswerConnect allows the user to specify
the condition under which the link is connected.
The options are:
onPowerOn - On power on.
whenAnyStationOnLan - When any station on lan.
onTraffic - On traffic. The user can specify the
condition/s for connection.
The connection will be defined in
CODSpecificOnTrafficConditionOID .
onManualConnect - depends on radBridgeCODManualConnect
OBJECT-TYPE .
"
::= { radBridgeCODCondEntry 5 }
radBridgeCODSpecificOnTrafficOIDCondition OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to a specific entry in the
radBridgeMaskTable, which describes the
particular COD condition .
If Connect or Disconnect Conditions are not
onTraffic, its value should be set to the
OBJECT IDENTIFIER { 0 0 }. "
::= { radBridgeCODCondEntry 6 }
radBridgeCODDisConnectMinimunFramesNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frames rate."
::= { radBridgeCODCondEntry 7 }
--The IPX following objects define the Spoofing
radBridgeIPX OBJECT IDENTIFIER ::= {genBridge 5 }
radBridgeIPXdriver OBJECT IDENTIFIER ::= {radBridgeIPX 1 }
radBridgeIPXRip OBJECT IDENTIFIER ::= {radBridgeIPX 2 }
radBridgeIPXSap OBJECT IDENTIFIER ::= {radBridgeIPX 3 }
radBridgeIPXForwarding OBJECT-TYPE
SYNTAX INTEGER {
forwarding(1),
not-forwarding(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The indication of whether this entity is acting as an IPX
gateway in respect to the forwarding of datagrams received by,
but not addressed to, this entity. IPX gateways forward
datagrams. IPX hosts do not. Note that changing this parameter
requiers RESET of the router."
-- DEFVAL { 1 }
::= { radBridgeIPXdriver 1 }
radBridgeIPXRipOutPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted by RIP."
::= { radBridgeIPXRip 1 }
radBridgeIPXRipInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by RIP. This will include
any packets that are subsequently discarded."
::= { radBridgeIPXRip 2 }
radBridgeIPXRipInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded by RIP."
::= { radBridgeIPXRip 3 }
radBridgeIPXRipTblNoOfEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of entries that exist in the RIP routing table."
::= { radBridgeIPXRip 4 }
radBridgeIPXRipTblBcastTrigUpdateInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default time interval (in seconds)between triggered RIP updates on
a broadcast type interface. A triggered update occurs when a change is
detected in the routing database. This time interval delays the
broadcasting of these updates so that changes on the network will
not result in a lot of triggered updates."
::= { radBridgeIPXRip 5 }
radBridgeIPXRipTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIPXRipTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The routing table used by RIP to calculate routes to remote
desination networks."
::= { radBridgeIPXRip 6 }
radBridgeIPXRipTableEntry OBJECT-TYPE
SYNTAX RadBridgeIPXRipTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The routing information for one of this entity's destination networks."
INDEX { radBridgeIPXRipDestNetwork,
radBridgeIPXRipPolicy }
::= { radBridgeIPXRipTable 1 }
RadBridgeIPXRipTableEntry ::= SEQUENCE {
radBridgeIPXRipDestNetwork
OCTET STRING (SIZE(4)),
radBridgeIPXRipPolicy
INTEGER,
radBridgeIPXRipForwardingRouter
OCTET STRING (SIZE(6)),
radBridgeIPXRipNIC
Integer32,
radBridgeIPXRipTickMetric
Integer32,
radBridgeIPXRipHopMetric
Integer32,
radBridgeIPXRipAgingTime
TimeTicks,
radBridgeIPXRipValueStatus
INTEGER,
radBridgeIPXRipForwardType
INTEGER
}
radBridgeIPXRipDestNetwork OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The destination network address to which this entry's
routing information pertains."
::= {radBridgeIPXRipTableEntry 1 }
radBridgeIPXRipPolicy OBJECT-TYPE
SYNTAX INTEGER {
main(1),
alternate(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A value specifying the precidence of the route. A value of
zero means that the route is the best route, a value of one
means that the route is the second best route and so on."
::= { radBridgeIPXRipTableEntry 2 }
radBridgeIPXRipForwardingRouter OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPX node address of the next hop (router) for the
entry's associated destination network."
::= { radBridgeIPXRipTableEntry 3 }
radBridgeIPXRipNIC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An interface identifier specifying what IPX interface the
next hop can be found on."
::= { radBridgeIPXRipTableEntry 4 }
radBridgeIPXRipTickMetric OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The metric, in terms of transit time, associated with the route
given by the entry. This time is in terms of 1/18ths of a
second."
::= { radBridgeIPXRipTableEntry 5 }
radBridgeIPXRipHopMetric OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The metric, in terms of distance , associated with the route
given by the entry."
::= { radBridgeIPXRipTableEntry 6 }
radBridgeIPXRipAgingTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last time that the entry was updated. The time will be
provided in terms of the MIB-I object sysUpTime."
::= {radBridgeIPXRipTableEntry 7 }
radBridgeIPXRipValueStatus OBJECT-TYPE
SYNTAX INTEGER {
static(1),
dynamic(2),
invalid(3),
semiDynamic(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The entry status value; whether the entry is permanent (added
statically), reachable or unreachable. In the latter two cases
it would be added by RIP. A semiDynamic entry is an entry
enterd manualy by the user and can be updated by the router."
::= { radBridgeIPXRipTableEntry 8 }
radBridgeIPXRipForwardType OBJECT-TYPE
SYNTAX INTEGER {
other (1), -- not specified by this MIB
local (2), -- local interface
remote (3) -- remote destination
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of route. Note that local(2) refers to a route for which the
next hop is the final destination; remote(3) refers to a route
for which the next hop is not the final destination."
::= {radBridgeIPXRipTableEntry 9 }
radBridgeIPXRipInfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIPXRipInfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RIP interface table."
::= { radBridgeIPXRip 7 }
radBridgeIPXRipInfEntry OBJECT-TYPE
SYNTAX RadBridgeIPXRipInfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry corresponds to one ifindex."
INDEX { radBridgeIPXRipInfIfIndex}
::= { radBridgeIPXRipInfTable 1 }
RadBridgeIPXRipInfEntry ::= SEQUENCE {
radBridgeIPXRipInfIfIndex
Integer32,
radBridgeIPXRipInfBcastUpdate
Integer32,
radBridgeIPXRipInfAgeMultiplier
Integer32
}
radBridgeIPXRipInfIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value of Ifindex is same as radBridgeIPXIfIndex in the
IPX Interface Table."
::= { radBridgeIPXRipInfEntry 1 }
radBridgeIPXRipInfBcastUpdate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The RIP periodic update interval, in seconds. Zero value
corresponds to infinite interval."
-- DEFVAL {60}
::= { radBridgeIPXRipInfEntry 2 }
radBridgeIPXRipInfAgeMultiplier OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holding multiplier for information received in RIP
periodic updates. Zero value corresponds to infinite aging time."
-- DEFVAL {3}
::= { radBridgeIPXRipInfEntry 3 }
radBridgeIPXSapOutPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets transmitted by SAP."
::= { radBridgeIPXSap 1 }
radBridgeIPXSapInPackets OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of packets received by SAP. This will include
any packets that are subsequently discarded."
::= { radBridgeIPXSap 2 }
radBridgeIPXSapInDiscards OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of received packets discarded by SAP."
::= { radBridgeIPXSap 3 }
radBridgeIPXSapTblNoOfEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The max number of entries that exist in the SAP Server
Information table."
::= { radBridgeIPXSap 4 }
radBridgeIPXSapTblBcastTrigUpdateInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The default time interval (in seconds) between triggered SAP updates on a
broadcast style interface. A triggered update occurs when a
change is detected in the service database. This time interval
delays the transmission of these updates so that changes on the
network will not result in a lot of triggered updates."
::= { radBridgeIPXSap 5 }
radBridgeIPXSapTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIPXSapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Server Information table is used by SAP to store information
of services which are available on the internetwork."
::= { radBridgeIPXSap 6 }
radBridgeIPXSapTableEntry OBJECT-TYPE
SYNTAX RadBridgeIPXSapTableEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The server information for one of this entity's server entries."
INDEX { radBridgeIPXSapServerType,
radBridgeIPXSapName }
::= { radBridgeIPXSapTable 1 }
RadBridgeIPXSapTableEntry ::= SEQUENCE {
radBridgeIPXSapServerType
Integer32,
radBridgeIPXSapName
DisplayString (SIZE(48)),
radBridgeIPXSapNetwork
OCTET STRING (SIZE(4)),
radBridgeIPXSapNode
OCTET STRING (SIZE(6)),
radBridgeIPXSapSocket
Integer32,
radBridgeIPXSapHopsToServer
Integer32,
radBridgeIPXSapNIC
Integer32,
radBridgeIPXSapAgingTime
TimeTicks,
radBridgeIPXSapStatus
INTEGER
}
radBridgeIPXSapServerType OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of the server for which this entry pertains."
::= { radBridgeIPXSapTableEntry 1 }
radBridgeIPXSapName OBJECT-TYPE
SYNTAX DisplayString (SIZE(48))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the server for which this entry pertains."
::= { radBridgeIPXSapTableEntry 2 }
radBridgeIPXSapNetwork OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(4))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPX network address of the host on which this server exists."
::= { radBridgeIPXSapTableEntry 3 }
radBridgeIPXSapNode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(6))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPX node address of the host on which this server exists."
::= { radBridgeIPXSapTableEntry 4 }
radBridgeIPXSapSocket OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The IPX socket number that is being used by the server to
which this entry pertains."
::= { radBridgeIPXSapTableEntry 5 }
radBridgeIPXSapHopsToServer OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of hops to the entity on which this server exists."
::= { radBridgeIPXSapTableEntry 6 }
radBridgeIPXSapNIC OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An Network Interface Card identifier specifying what IPX
interface the next hop can be found on."
::= { radBridgeIPXSapTableEntry 7 }
radBridgeIPXSapAgingTime OBJECT-TYPE
SYNTAX TimeTicks
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The last time that the entry was updated. The time will be
provided in terms of the MIB-I object sysUpTime."
::= { radBridgeIPXSapTableEntry 8 }
radBridgeIPXSapStatus OBJECT-TYPE
SYNTAX INTEGER {
permanent(1),
dynamic(2),
invalid(3),
semiDynamic(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of the entry."
::= { radBridgeIPXSapTableEntry 9 }
radBridgeIPXSapInfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIPXSapInfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Sap interface table."
::= { radBridgeIPXSap 7 }
radBridgeIPXSapInfEntry OBJECT-TYPE
SYNTAX RadBridgeIPXSapInfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry corresponds to one ifindex."
INDEX {radBridgeIPXSapInfIfIndex}
::= { radBridgeIPXSapInfTable 1 }
RadBridgeIPXSapInfEntry ::= SEQUENCE {
radBridgeIPXSapInfIfIndex
Integer32,
radBridgeIPXSapInfBcastUpdate
Integer32,
radBridgeIPXSapInfAgeMultiplier
Integer32
}
radBridgeIPXSapInfIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value of Ifindex is same as radBridgeIPXIfIndex in the
IPX Interface Table."
::= { radBridgeIPXSapInfEntry 1 }
radBridgeIPXSapInfBcastUpdate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The SAP periodic update interval, in seconds. Zero value
corresponds to infinite interval."
-- DEFVAL {60}
::= { radBridgeIPXSapInfEntry 2 }
radBridgeIPXSapInfAgeMultiplier OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The holding multiplier for information received in SAP
periodic updates. Zero value corresponds to infinite aging time."
-- DEFVAL {3}
::= { radBridgeIPXSapInfEntry 3 }
-- radMaskingTab defines the new format of RAD Bridge masking tables
GenAddress ::= OCTET STRING (SIZE(12))
newMasking OBJECT IDENTIFIER ::= {genBridge 6 }
maskingMaxEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum number of entries in the masking table."
::= { newMasking 1 }
maskingCurrentEntries OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of entries in the mask table."
::= { newMasking 2 }
maskingTable OBJECT-TYPE
SYNTAX SEQUENCE OF MaskingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This is the new masking scheme.
Mask tables enable definition of forwarding restrictions and
control of message flow in the internetwork. Each entry
in this table defines a mask statement and an action defined by
maskingOperation."
::= { newMasking 3 }
maskingEntry OBJECT-TYPE
SYNTAX MaskingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the mask table."
INDEX { maskingType, maskingIfIndex, maskingIndex }
::= { maskingTable 1 }
MaskingEntry ::= SEQUENCE {
maskingType
INTEGER,
maskingIfIndex
Integer32,
maskingIndex
Integer32,
maskingProtocolType
INTEGER,
maskingSmartMaskOID
OBJECT IDENTIFIER,
maskingFrameType
INTEGER,
maskingFrameTypeCondition
INTEGER,
maskingSourceAddress
GenAddress,
maskingSourceActiveBits
GenAddress,
maskingSourceMacOrNet
INTEGER,
maskingSourceCondition
INTEGER,
maskingDestAddress
GenAddress,
maskingDestActiveBits
GenAddress,
maskingDestMacOrNet
INTEGER,
maskingDestCondition
INTEGER,
maskingLowLevelProt
INTEGER,
maskingLowLevelProtCondition
INTEGER,
maskingHighLevelProt
Integer32,
maskingHighLevelProtCondition
INTEGER,
maskingPortNum
Integer32,
maskingPortNumCondition
INTEGER,
maskingOperation
INTEGER,
maskingSrcPortNum
Integer32,
maskingSrcPortNumCondition
INTEGER
}
maskingType OBJECT-TYPE
SYNTAX INTEGER {
tx (1),
rx (2),
compress(3),
priority(4),
loadSharing(5),
facs(6),
codConnect(7),
codDisconnect(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines the type of mask entry. "
::= { maskingEntry 1 }
maskingIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the ifIndex of the interface to which the mask is applied."
::= { maskingEntry 2 }
maskingIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An index to the masking table. This number should not be greater than maskingMaxEntries"
::= { maskingEntry 3 }
maskingProtocolType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
ip (2),
ipx (3),
sna (4),
netbios (5),
apple (6),
dec (7),
all (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The base protocol for masking. IPX, IP, others."
::= { maskingEntry 4 }
maskingSmartMaskOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A reference to a specific Smart mask table (old radBridgeMaskTable)
which enables a more specific mask type.
If this information is not available, its value
should be set to the OBJECT IDENTIFIER { 0 0 }. "
::= { maskingEntry 5 }
maskingFrameType OBJECT-TYPE
SYNTAX INTEGER {
unknown (1),
all (2),
broadcast (3),
multicast (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables the user to decide about frame type
* all frame
* just broadcast
* just multicast."
::= { maskingEntry 6 }
maskingFrameTypeCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingFrameType the packet contains data that matches
the content of maskingFrameType.
fa lse - Condition is valid if at the position specified by
maskingFrameType the packet contains data that does not
match the content of maskingFrameType."
::= { maskingEntry 7 }
maskingSourceAddress OBJECT-TYPE
SYNTAX GenAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source address is according to the maskingMacOrNet and
maskingProtocolType variables.
In case of 'MAC' enter 6 bytes (48 bit) of source address.
In case of 'NET'
if the maskingProtocolType is IP, this is the IP address
if the maskingProtocolType is IPX, this is the IPX address
(nnnnmmmmmmss)
nnnn - IPX net address
mmmmmm - Node address (Mac)
ss - IPX socket
In case of 'Apple'
nn - net address (4 nibbles)
ss - socket (4 nibbles)."
::= { maskingEntry 8 }
maskingSourceActiveBits OBJECT-TYPE
SYNTAX GenAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the positions of the wild card characters (*)
in the maskingSourceAddress field. Only the 1's bit will be taken in
considerations."
::= { maskingEntry 9 }
maskingSourceMacOrNet OBJECT-TYPE
SYNTAX INTEGER {
macAddress (1),
netAddress (2),
ipRange (3),
appleAddress(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The variable maskingSourceAddress and maskingSourceActiveBits
will be treated as MAC, or NET address.
- If maskingProtocolType = 'all', 'sna', 'netbios', dec or
'unknown', the maskingSourceMacOrNet can be macAddress only!
- If maskingProtocolType = 'ip' the
maskingSourceMacOrNet can be macAddress or netAddress or
appleAddress.
- If maskingProtocolType = 'ipx', the
maskingSourceMacOrNet can be either macAddress or netAddress.
- If maskingProtocolType = 'apple', the
maskingSourceMacOrNet can be either macAddress or appleAddress."
::= { maskingEntry 10 }
maskingSourceCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingSourceAddress (in conjunction with maskingSourceActiveBits)
the packet contains data that matches the content of maskingSourceAddress.
false - Condition is valid if at the position specified by
maskingSourceAddress (in conjunction with maskingSourceActiveBits)
the packet contains data that does not match the content of
maskingSourceAddress."
::= { maskingEntry 11 }
maskingDestAddress OBJECT-TYPE
SYNTAX GenAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If maskingFrameType = broadcast or multicast, this object
is NOT APPLICABLE.
If maskingFrameType = all or unknown, this object is
applicable.
The destination address is according to the maskingMacOrNet and maskingProtocolType variables.
In case of 'MAC' enter 6 bytes (48 bit) of source address.
In case of 'NET'
if the maskingProtocolType is IP, this is the IP address
if the maskingProtocolType is IPX, this is the IPX address
(nnnnmmmmmmss)
nnnn - IPX net address
mmmmmm - Node address (Mac)
ss - IPX socket.
In case of 'Apple'
nn - net address (4 nibbles)
ss - socket (4 nibbles).
The IPX socket entered here has priority over the value of
maskingLowLevelProt, when it is ipxRip, ipxSap or ipxSpx,
unless the entered IPX socket is don't care. "
::= { maskingEntry 12 }
maskingDestActiveBits OBJECT-TYPE
SYNTAX GenAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If maskingFrameType = broadcast or multicast, this object
is NOT APPLICABLE.
If maskingFrameType = all or unknown, this object is
applicable.
Specifies the positions of the wild card characters (*)
in the maskingDestAddress field. Only the 1's bit will be taken in
considerations."
::= { maskingEntry 13 }
maskingDestMacOrNet OBJECT-TYPE
SYNTAX INTEGER {
macAddress (1),
netAddress (2),
ipRange (3),
appleAddress(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If maskingFrameType = broadcast or multicast, this object
is NOT APPLICABLE.
If maskingFrameType = all or unknown, this object is
applicable.
- If maskingProtocolType = 'all', 'sna', 'netbios', dec or
'unknown', the maskingDestMacOrNet can be macAddress only!
- If maskingProtocolType = 'ip' the
maskingDestMacOrNet can be macAddress or netAddress or
appleAddress.
- If maskingProtocolType = 'ipx', the
maskingDestMacOrNet can be either macAddress or netAddress.
- If maskingProtocolType = 'apple', the
maskingDestMacOrNet can be either macAddress or appleAddress.
The variable maskingDestAddress and maskingDestActiveBits will
be treated as MAC, or NET address. "
::= { maskingEntry 14 }
maskingDestCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"If maskingFrameType = broadcast or multicast, this object
is NOT APPLICABLE.
If maskingFrameType = all or unknown, this object is
applicable.
Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingDestAddress (in conjunction with maskingDestActiveBits)
the packet contains data that matches the content of maskingDestAddress.
false - Condition is valid if at the position specified by
maskingDestAddress (in conjunction with maskingDestActiveBits)
the packet contains data that does not match the content of maskingDestAddress."
::= { maskingEntry 15 }
maskingLowLevelProt OBJECT-TYPE
SYNTAX INTEGER {
unknown (1), -- don't care
ipxRip (2), -- 0x51
ipxSap (3), -- 0x52
ipxSpx (4), -- 0x53
ipUdp (5), -- 0x54
ipTcp (6), -- 0x55
ipIcmp (7), -- 0x56
ipxNcp (8), -- 0x57
ipxWan (9), -- 0x58
ipxEco (10), -- 0x59
ipxErr (11), -- 0x5a
ipxPep (12) -- 0x5b
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field is set in conjunction with the maskingProtocolType variable.
This variable specifies the low level protocol.
The IPX socket entered in maskingDestAddress has priority
over the value of maskingLowLevelProt, when it is ipxRip,
ipxSap or ipxSpx, unless the entered IPX socket is don't
care."
::= { maskingEntry 16 }
maskingLowLevelProtCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingLowLevelProt the packet contains data that matches
the content of maskingLowLevelProt.
false - Condition is valid if at the position specified by
maskingLowLevelProt the packet contains data that does not
match the content of maskingLowLevelProt."
::= { maskingEntry 17 }
maskingHighLevelProt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This field is set in connection to the maskingProtocolType variable.
This variable specifies the high level protocols (application).
As for today it supports just IP protocol stack.
The object's value is a sum of the following instances values
(selected by user):
none (0), -- don't care
ftp (1),
ftpC (2),
telnet (4),
smtp (8),
tftp (16),
snmp (32),
snmpTrap (64),
ipRip (128),
www (256),
email (512),
dns (1024),
For Apple Protocol only:
rtmp (2048),
nbp (4096),
atp (8192),
aep (16384),
zip (32768),
adsp (65536),
pap (131072),
asp (262144)
Example: if ftp(1), snmp(32) and snmpTrap(64) instances
were selected, the value should be 97 (=1+32+64)."
::= { maskingEntry 18 }
maskingHighLevelProtCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingHighLevelProt the packet contains data that matches
the content of maskingHighLevelProt.
false - Condition is valid if at the position specified by
maskingHighLevelProt the packet contains data that does not
match the content of maskingHighLevelProt."
::= { maskingEntry 19 }
maskingPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The port number is the same as in high level protocol. It
specifies the dest. port in IP case or the dest. socket
in case of IPX & apple protocols.
IP - This object is applicable only if none (0) value was selected in
maskingHighLevelProt.
IPX - This object is applicable only if the socket
entered in maskingDestAddress is 'don't care'(00) AND
maskingLowLevelProt is NOT ipxRip or ipxSap.
Apple - This option is applicable only if the socket
entered in maskingDestAddress is 'don't care'(00)."
::= { maskingEntry 20 }
maskingPortNumCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Specifies the logical condition of the mask pattern:
true - Condition is valid if at the position specified by
maskingPortNum the packet contains data that matches
the content of maskingPortNum.
false - Condition is valid if at the position specified by
maskingPortNum the packet contains data that does not
match the content of maskingPortNum.
This object is applicable only when maskingPortNum is applicable."
::= { maskingEntry 21 }
maskingOperation OBJECT-TYPE
SYNTAX INTEGER {
block (1),
forward (2),
route (3),
forward-route (4),
high-priority (5),
noOp (6),
delete (7),
smartMask (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of action to be taken if the frame meets the
conditions of the mask.
noOp = disabled (mask remains on list, but is not active)
delete = mask is removed from the list.
smartMask = the operation and destination of the mask will
be determined by the objects of the Smart Table
(old masking table: radBridgeMaskTable).
If maskingType is codConnect, the 'block' value is NOT
allowed.
If maskingType is codDisconnect, the 'forward' value is NOT
allowed."
::= { maskingEntry 22 }
maskingSrcPortNum OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source port number.
For IP: No Condition.
For IPX: This object is applicable only if the socket entered in
maskingSourceAddress is don't care (00) and maskingLowLevelProt
is NOT ipxRip or ipxSap.
For Apple:This object is applicable only if the socket entered in
maskingSourceAddress is don't care (00). "
::= { maskingEntry 23 }
maskingSrcPortNumCondition OBJECT-TYPE
SYNTAX INTEGER {
false (1),
true (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The same as 'maskingPortNumCondition'.
Relates to source port."
::= { maskingEntry 24 }
radBridgePerformance OBJECT IDENTIFIER ::= {genBridge 7 }
-- The RAD Bridge current table contains statistics being
-- collected for the current 15 minute interval.
radBridgeCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RAD Bridge Current table."
::= { radBridgePerformance 1 }
radBridgeCurrentEntry OBJECT-TYPE
SYNTAX RadBridgeCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the RAD Bridge Current table."
INDEX { radBridgeCurrentIndex }
::= { radBridgeCurrentTable 1 }
RadBridgeCurrentEntry ::=
SEQUENCE {
radBridgeCurrentIndex
Integer32,
radBridgeCurrentIngressFilteringDiscardedFrames
Gauge32,
radBridgeCurrentFrameTypeDiscardedFrames
Gauge32
}
radBridgeCurrentIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Bridge interface.
It may be ifIndex."
::= { radBridgeCurrentEntry 1 }
radBridgeCurrentIngressFilteringDiscardedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
Frames upon Ingress Filtering, encountered by a Bridge
interface in the current 15 minute interval."
::= { radBridgeCurrentEntry 2 }
radBridgeCurrentFrameTypeDiscardedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
Frames upon Frame Type and Tagging Mismatch, encountered
by a Bridge interface in the current 15 minute interval."
::= { radBridgeCurrentEntry 3 }
--Interval Table
-- The RAD Bridge Interval table contains statistics being
-- collected by each Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
radBridgeIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The RAD Bridge Interval table."
::= { radBridgePerformance 2 }
radBridgeIntervalEntry OBJECT-TYPE
SYNTAX RadBridgeIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the RAD Bridge Interval table."
INDEX { radBridgeIntervalIndex, radBridgeIntervalNumber }
::= { radBridgeIntervalTable 1 }
RadBridgeIntervalEntry ::=
SEQUENCE {
radBridgeIntervalIndex
Integer32,
radBridgeIntervalNumber
Integer32,
radBridgeIntervalIngressFilteringDiscardedFrames
Gauge32,
radBridgeIntervalFrameTypeDiscardedFrames
Gauge32
}
radBridgeIntervalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the bridge interface.
It may be ifIndex."
::= { radBridgeIntervalEntry 1 }
radBridgeIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { radBridgeIntervalEntry 2 }
radBridgeIntervalIngressFilteringDiscardedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
Frames upon Ingress Filtering, encountered by a
Bridge interface in one of the previous 96, individual
15 minute, intervals."
::= { radBridgeIntervalEntry 3 }
radBridgeIntervalFrameTypeDiscardedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
Frames upon Frame Type and Tagging Mismatch, encountered
by a Bridge interface in one of the previous 96, individual
15 minute, intervals."
::= { radBridgeIntervalEntry 4 }
radBridgePortBaseVlan OBJECT IDENTIFIER ::= {genBridge 8 }
radBridgePortBaseVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgePortBaseVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing static configuration information for
each VLAN configured into the device by management.
All entries are permanent and will
be restored after the device is reset."
::= { radBridgePortBaseVlan 1 }
radBridgePortBaseVlanEntry OBJECT-TYPE
SYNTAX RadBridgePortBaseVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Static information for a VLAN configured into the
device by (local or network) management."
INDEX { radBridgePortBaseVlanCnfgIdx,radBridgePortBaseVlanIdx }
::= { radBridgePortBaseVlanTable 1 }
RadBridgePortBaseVlanEntry ::=
SEQUENCE {
radBridgePortBaseVlanCnfgIdx Integer32,
radBridgePortBaseVlanIdx Integer32,
radBridgePortBaseVlanName SnmpAdminString,
radBridgePortBaseVlanEgressPorts PortList,
radBridgePortBaseVlanVirtualGroups PortList,
radBridgePortBaseVlanRowStatus RowStatus,
radBridgePortBaseVlanMng INTEGER
}
radBridgePortBaseVlanCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Agent Cnfg the following
objects refer.
255=Temporary Cnfg (when relevant,
Set is done only to this configuration).
For Agents that support only one configuration,
this object will be constant=1. "
::= { radBridgePortBaseVlanEntry 1 }
radBridgePortBaseVlanIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the port based VLAN."
::= { radBridgePortBaseVlanEntry 2 }
radBridgePortBaseVlanName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (0..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An administratively assigned string, which may be used
to identify the the port based VLAN."
::= { radBridgePortBaseVlanEntry 3 }
radBridgePortBaseVlanEgressPorts OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of ports which are permanently assigned to the
egress list for this port based VLAN by management.
The default value of this object is a string of zeros."
::= { radBridgePortBaseVlanEntry 4 }
radBridgePortBaseVlanVirtualGroups OBJECT-TYPE
SYNTAX PortList
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The set of Virtual Groups which are permanently assigned to
this port based VLAN by management.
(read Virtual Group instead of port in PortList Textual Convention)
The default value of this object is a string of zeros."
::= { radBridgePortBaseVlanEntry 5 }
radBridgePortBaseVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enable user to
create/delete entries in this table."
::= { radBridgePortBaseVlanEntry 6 }
radBridgePortBaseVlanMng OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object allows user to enable/disable
management traffic on this VLAN."
::= { radBridgePortBaseVlanEntry 7 }
-- The Bridge's Ports-VLANs Memebership Table
radBridgePortVlanMemberTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgePortVlanMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Bridge Ports-VLAN Membership table.
This table enables the user to assign:
- Several VLANs to a Port.
- Several Ports to a VLAN."
::= { radBridgePortBaseVlan 2 }
radBridgePortVlanMemberEntry OBJECT-TYPE
SYNTAX RadBridgePortVlanMemberEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Bridge Ports-VLANs Memebership table."
INDEX { radBridgePortVlanMemberBridgeIdx,
radBridgePortVlanMemberPortIdx,
radBridgePortVlanMemberVlanId }
::= { radBridgePortVlanMemberTable 1 }
RadBridgePortVlanMemberEntry ::=
SEQUENCE {
radBridgePortVlanMemberBridgeIdx Integer32,
radBridgePortVlanMemberPortIdx Integer32,
radBridgePortVlanMemberVlanId Integer32,
radBridgePortVlanMemberRowStatus RowStatus
}
radBridgePortVlanMemberBridgeIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Bridge Index."
::= { radBridgePortVlanMemberEntry 1 }
radBridgePortVlanMemberPortIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Bridge's Port Index.
For some cases, it can be used as the Port ofIndex."
::= { radBridgePortVlanMemberEntry 2 }
radBridgePortVlanMemberVlanId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the VLAN ID."
::= { radBridgePortVlanMemberEntry 3 }
radBridgePortVlanMemberRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries in this table."
::= { radBridgePortVlanMemberEntry 4 }
radBridgeGenCnfg OBJECT IDENTIFIER ::= {genBridge 9 }
radBridgeGenFlowTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeGenFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing static configuration information for
Bridge configured into the device by (local or
network) management. All entries are permanent and will
be restored after the device is reset."
::= { radBridgeGenCnfg 1 }
radBridgeGenFlowEntry OBJECT-TYPE
SYNTAX RadBridgeGenFlowEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Static information for a Bridge configured into the
device by management."
INDEX { radBridgeGenFlowCnfgIdx,radBridgeGenFlowIdx }
::= { radBridgeGenFlowTable 1 }
RadBridgeGenFlowEntry ::=
SEQUENCE
{
radBridgeGenFlowCnfgIdx Integer32,
radBridgeGenFlowIdx Integer32,
radBridgeGenFlowRowStatus RowStatus,
radBridgeGenFlowFloodOrBcastMaxRate Integer32,
radBridgeGenFlowQosMode INTEGER,
radBridgeGenFlowSchedulingMode INTEGER
}
radBridgeGenFlowCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the
Agent Cnfg the following objects refer.
255=Temporary Cnfg (when relevant,
Set is done only to this configuration).
For Agents that support only one configuration,
this object will be constant=1. "
::= { radBridgeGenFlowEntry 1 }
radBridgeGenFlowIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"For Agent having more than one bridge,
this index may be used as bridge index "
::= { radBridgeGenFlowEntry 2 }
radBridgeGenFlowRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enable user to
create/delete entries in this table."
::= { radBridgeGenFlowEntry 3 }
radBridgeGenFlowFloodOrBcastMaxRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls maximum Flooding or Broadcast Rate:
Max number of multicast along with unknown
or flooded unicast frames allowed to enter
any port.
The number is presented as percentage of bandwidth.
Once the limit is exceeded, any multicast or flooded
frame entering from the port is discarded
For RIC-155 valid values are 0-100
For FCD-155 valid values are 3% , 6%, 12%
and 100% = No Limit "
::= { radBridgeGenFlowEntry 4 }
radBridgeGenFlowQosMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
vlanTag (2),
dscp (3),
dscpAndVlanTag (4),
vlanTagAndDscp (5),
none (6)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls Quality of Service mode.
User may select which field(s)
(in case of fields - which one has precedence)
will affect prioritization of data between egress queues."
::= { radBridgeGenFlowEntry 5 }
radBridgeGenFlowSchedulingMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
wfq (2), -- Weighted Fair Queuing
sp (3) -- Strict Priority
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls which scheduling mode is used:
Weighted Fair Queuing (WFQ) scheme or Strict Priority (SP)."
::= { radBridgeGenFlowEntry 6 }
radBridgeStatus OBJECT IDENTIFIER ::= {genBridge 10 }
radBridgeInvBasePortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RadBridgeInvBasePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An inversed table to dot1dBasePortTable
from RFC1493 with reduced information.
This table index is known to the NMS and
this way the needed information can be received
by just one Get command, instead of searching
the entire dot1dBasePortTable (where it is an
attribute). "
::= { radBridgeStatus 1 }
radBridgeInvBasePortEntry OBJECT-TYPE
SYNTAX RadBridgeInvBasePortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The bridge port number for each bridge port
interface index."
INDEX { radBridgeInvBasePortIfIndex }
::= { radBridgeInvBasePortTable 1 }
RadBridgeInvBasePortEntry ::=
SEQUENCE {
radBridgeInvBasePortIfIndex Integer32,
radBridgeInvBasePort Integer32
}
radBridgeInvBasePortIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The value of the instance of the ifIndex object,
defined in MIB-II, for the interface corresponding
to this Bridge port."
::= { radBridgeInvBasePortEntry 1 }
radBridgeInvBasePort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Bridge port number."
::= { radBridgeInvBasePortEntry 2 }
-- END --
-- file :v:\doc\rdv\mib\ver495\radsonet.txt
--
-- RAD-SONET-MIB DEFINITIONS ::= BEGIN
--Title: RAD-SONET MIB ver495
--
-- IMPORTS
-- Gauge32 FROM RFC1155-SMI
-- ifIndex FROM RFC1213-MIB
-- OBJECT-TYPE FROM RFC-1212
-- radWan FROM RAD-GEN-MIB;
-- RAD-SONET MIB
--Title: RAD's SONET INTERFACE MIB
--Version: 1.0
--Date: 13.10.96
--By: Yair Arian
--File: sonet.mib
--
--Last update: 25-Septemper-2002 by Yig'al Hachmon
sonetInterface OBJECT IDENTIFIER ::= {diverseIfWanGen 2}
prtSonetPerfHistory OBJECT IDENTIFIER ::= {sonetInterface 1}
-- The SONET Medium Table
prtSonetMediumTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetMediumEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET Medium table."
::= { prtSonetPerfHistory 1 }
prtSonetMediumEntry OBJECT-TYPE
SYNTAX PrtSonetMediumEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Medium table. ifIndex of the
lowest SONET layer of type sonet(39)."
INDEX { ifIndex }
::= { prtSonetMediumTable 1 }
PrtSonetMediumEntry ::=
SEQUENCE {
prtSonetMediumTimeElapsed
Integer32,
prtSonetMediumValidIntervals
Integer32
}
prtSonetMediumTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the near end current error-
measurement period."
::= { prtSonetMediumEntry 1 }
prtSonetMediumValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous near end intervals for
which valid data was collected. The value will be
96 unless the interface was brought online within
the last 24 hours, in which case the value will be
the number of complete 15 minute near end
intervals since the interface has been online."
::= { prtSonetMediumEntry 2 }
-- The SONET Section/Line Current Table
-- The SONET Section/Line Current table contains various statistics being
-- collected for the current 15 minute interval.
prtSonetSectionLineCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSectionLineCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET Section/Line Current table."
::= { prtSonetPerfHistory 2 }
prtSectionLineCurrentEntry OBJECT-TYPE
SYNTAX PrtSectionLineCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Section/Line Current table.
ifIndex of the section/line SONET layer of type
sonet(39)."
INDEX { ifIndex }
::= { prtSonetSectionLineCurrentTable 1 }
PrtSectionLineCurrentEntry ::=
SEQUENCE {
prtSonetCurrentLOS
Gauge32,
prtSonetCurrentLOF
Gauge32,
prtSonetCurrentLineAIS
Gauge32,
prtSonetCurrentLineFERF
Gauge32,
prtSonetCurrentSectionBIP
Gauge32,
prtSonetCurrentLineBIP
Gauge32,
prtSonetCurrentLineFEBE
Gauge32,
prtSonetCurrentUAS
Gauge32,
prtSonetCurrentSES
Gauge32,
prtSonetCurrentES
Gauge32,
prtSonetCurrentStatus
OCTET STRING,
prtSonetCurrentLSV
Gauge32
}
prtSonetCurrentLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds, encountered by a SONET interface in
the current 15 minute interval."
::= { prtSectionLineCurrentEntry 1 }
prtSonetCurrentLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 2 }
prtSonetCurrentLineAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line AIS
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 3 }
prtSonetCurrentLineFERF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
FERF seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 4 }
prtSonetCurrentSectionBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Section
BIP errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 5 }
prtSonetCurrentLineBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
BIP errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 6 }
prtSonetCurrentLineFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
FEBE errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 7 }
prtSonetCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS
encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 8 }
prtSonetCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a SONET
interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 9 }
prtSonetCurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds, encountered by a
SONET interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 10 }
prtSonetCurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - O.K.
1 - The link has been switched by a redundancy mechanism.
2 - Module is in/out.
4 - Empty - card is out."
::= { prtSectionLineCurrentEntry 11 }
prtSonetCurrentLSV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LSV
seconds (Line Symbol Violation), encountered by a
SONET interface in the current 15 minute interval."
::= { prtSectionLineCurrentEntry 12 }
-- The SONET Section/Line interface Interval
-- The SONET Section/Line Interval Table contains various statistics
-- collected by the Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
prtSonetSectionLineIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSectionLineIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Section/Line Interval table."
::= { prtSonetPerfHistory 3 }
prtSectionLineIntervalEntry OBJECT-TYPE
SYNTAX PrtSectionLineIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Section/Line Interval table.
ifIndex of the section/line SONET layer of type
sonet(39)."
INDEX { ifIndex, prtSonetLineIntervalNumber }
::= { prtSonetSectionLineIntervalTable 1 }
PrtSectionLineIntervalEntry ::=
SEQUENCE {
prtSonetLineIntervalNumber
Integer32,
prtSonetIntervalLOS
Gauge32,
prtSonetIntervalLOF
Gauge32,
prtSonetIntervalLineAIS
Gauge32,
prtSonetIntervalLineFERF
Gauge32,
prtSonetIntervalSectionBIP
Gauge32,
prtSonetIntervalLineBIP
Gauge32,
prtSonetIntervalLineFEBE
Gauge32,
prtSonetIntervalUAS
Gauge32,
prtSonetIntervalSES
Gauge32,
prtSonetIntervalES
Gauge32,
prtSonetIntervalStatus
OCTET STRING,
prtSonetIntervalLSV
Gauge32 }
prtSonetLineIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { prtSectionLineIntervalEntry 1 }
prtSonetIntervalLOS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOS
seconds , encountered by a SONET interface in
one of the previous 96, individual 15 minute,
intervals."
::= { prtSectionLineIntervalEntry 2 }
prtSonetIntervalLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOF
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 3 }
prtSonetIntervalLineAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
AIS seconds, encountered by a SONET
interface in one of the previous 96,
individual 15 minute, intervals."
::= { prtSectionLineIntervalEntry 4 }
prtSonetIntervalLineFERF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
FERF seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 5 }
prtSonetIntervalSectionBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Section
BIP errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 6 }
prtSonetIntervalLineBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
BIP errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 7 }
prtSonetIntervalLineFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Line
FEBE errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 8 }
prtSonetIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of UAS
encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 9 }
prtSonetIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SES
encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 10 }
prtSonetIntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Errored Seconds, encountered by a
SONET interface in one of the previous 96, individual 15
minute, intervals."
::= { prtSectionLineIntervalEntry 11 }
prtSonetIntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The statuses of the current interval:
0 - O.K.
1 - The link has been switched by a redundancy mechanism.
2 - Module is in/out.
4 - Empty - card is out."
::= { prtSectionLineIntervalEntry 12 }
prtSonetIntervalLSV OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LSV seconds
(Line Symbol Violation), encountered by a SONET interface
in one of the previous 96, individual 15 minute, intervals."
::= { prtSectionLineIntervalEntry 13 }
-- The SONET Path Current Table
-- The SONET Path Current table contains various statistics being
-- collected for the current 15 minute interval.
prtSonetPathCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET Path Current table."
::= { prtSonetPerfHistory 4 }
prtPathCurrentEntry OBJECT-TYPE
SYNTAX PrtPathCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Path Current table.
ifIndex of the Path SONET layer of type
sonetPath(50)."
INDEX { ifIndex }
::= { prtSonetPathCurrentTable 1 }
PrtPathCurrentEntry ::=
SEQUENCE {
prtSonetCurrentPathAIS
Gauge32,
prtSonetCurrentPathFERF
Gauge32,
prtSonetCurrentLOP
Gauge32,
prtSonetCurrentSLM
Gauge32,
prtSonetCurrentLOC
Gauge32,
prtSonetCurrentPathBIP
Gauge32,
prtSonetCurrentPathFEBE
Gauge32
}
prtSonetCurrentPathAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path AIS
seconds, encountered by a SONET interface in
the current 15 minute interval."
::= { prtPathCurrentEntry 1 }
prtSonetCurrentPathFERF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path FERF
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 2 }
prtSonetCurrentLOP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number LOP
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 3 }
prtSonetCurrentSLM OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SLM
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 4 }
prtSonetCurrentLOC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOC
seconds, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 5 }
prtSonetCurrentPathBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
BIP errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 6 }
prtSonetCurrentPathFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
FEBE errors, encountered by a SONET
interface in the current 15 minute interval."
::= { prtPathCurrentEntry 7 }
-- The SONET Path interface Interval
-- The SONET Path Interval Table contains various statistics
-- collected by the Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
prtSonetPathIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtPathIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Path Interval table."
::= { prtSonetPerfHistory 5 }
prtPathIntervalEntry OBJECT-TYPE
SYNTAX PrtPathIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET Path Interval table."
INDEX { ifIndex, prtSonetPathIntervalNumber }
::= { prtSonetPathIntervalTable 1 }
PrtPathIntervalEntry ::=
SEQUENCE {
prtSonetPathIntervalNumber
Integer32,
prtSonetIntervalPathAIS
Gauge32,
prtSonetIntervalPathFERF
Gauge32,
prtSonetIntervalLOP
Gauge32,
prtSonetIntervalSLM
Gauge32,
prtSonetIntervalLOC
Gauge32,
prtSonetIntervalPathBIP
Gauge32,
prtSonetIntervalPathFEBE
Gauge32
}
prtSonetPathIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { prtPathIntervalEntry 1 }
prtSonetIntervalPathAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
AIS seconds , encountered by a SONET interface in
one of the previous 96, individual 15 minute,
intervals."
::= { prtPathIntervalEntry 2 }
prtSonetIntervalPathFERF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
FERF seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 3 }
prtSonetIntervalLOP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOP
seconds, encountered by a SONET
interface in one of the previous 96,
individual 15 minute, intervals."
::= { prtPathIntervalEntry 4 }
prtSonetIntervalSLM OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SLM
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 5 }
prtSonetIntervalLOC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of LOC
seconds, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 6 }
prtSonetIntervalPathBIP OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
BIP errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 7 }
prtSonetIntervalPathFEBE OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Path
FEBE errors, encountered by a SONET
interface in one of the previous 96, individual 15
minute, intervals."
::= { prtPathIntervalEntry 8 }
virtualIfStatistics OBJECT IDENTIFIER ::= { prtSonetPerfHistory 6}
-- the Virtual Interface Current Table
virtualIfCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface Current table."
::= { virtualIfStatistics 1 }
virtualIfCurrentEntry OBJECT-TYPE
SYNTAX VirtualIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface Current table."
INDEX { ifIndex }
::= { virtualIfCurrentTable 1 }
VirtualIfCurrentEntry ::=
SEQUENCE {
virtualIfCurrentMinActiveVC Integer32,
virtualIfCurrentMaxActiveVC Integer32,
virtualIfCurrentRxFrames Counter64,
virtualIfCurrentTxFrames Counter64,
virtualIfCurrentRxAbortFrames PerfCurrentCount,
virtualIfCurrentTxAbortFrames PerfCurrentCount,
virtualIfCurrentMinLengthViolation PerfCurrentCount,
virtualIfCurrentMaxLengthViolation PerfCurrentCount,
virtualIfCurrentFcsError PerfCurrentCount,
virtualIfCurrentByteDestuffingViolation PerfCurrentCount,
virtualIfCurrentAdressMismatch PerfCurrentCount,
virtualIfCurrentControlMismatch PerfCurrentCount,
virtualIfCurrentActiveVC Integer32
}
virtualIfCurrentMinActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the minimum number of active virtual containers (VCs)
of the Virtual Concatenation Group in the current 15-minute interval."
::= { virtualIfCurrentEntry 1 }
virtualIfCurrentMaxActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..63)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the maximum number of active virtual containers (VCs)
of the Virtual Concatenation Group in the current 15-minute interval."
::= {virtualIfCurrentEntry 2 }
virtualIfCurrentRxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of frames received from STS-3/STM-1
by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 3}
virtualIfCurrentTxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of frames transmitted to STS-3/STM-1
by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 4 }
virtualIfCurrentRxAbortFrames OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Received Aborted frames
encountered by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 5 }
virtualIfCurrentTxAbortFrames OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Transmitted Aborted frames
encountered by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 6 }
virtualIfCurrentMinLengthViolation OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Rx payload Min Length Violation frames encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfCurrentEntry 7 }
virtualIfCurrentMaxLengthViolation OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Rx payload Max Length Violation frames
encountered by a Virtual Interface in the current 15-minute interval."
::= { virtualIfCurrentEntry 8 }
virtualIfCurrentFcsError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter is associated with the number of
Frame Check Sequence errors encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfCurrentEntry 9 }
virtualIfCurrentByteDestuffingViolation OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Byte De-stuffing Violations encountered by a Virtual Interface
in the current 15-minute interval."
::= {virtualIfCurrentEntry 10 }
virtualIfCurrentAdressMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Adress Mismatch encountered by a Virtual Interface
in the current 15-minute interval."
::= {virtualIfCurrentEntry 11 }
virtualIfCurrentControlMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Control Mismatch encountered by a Virtual Interface
in the current 15-minute interval."
::= {virtualIfCurrentEntry 12 }
virtualIfCurrentActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the number of active virtual containers (VCs)
of the Virtual Concatenation Group in the current 15-minute interval."
::= {virtualIfCurrentEntry 13 }
-- the Virtual Interface Interval Table
-- The Virtual Interface Interval Table
-- contains various statistics collected over a maximum
-- of the previous 24 hours of operation.
-- The past 24 hours may be broken into 96
-- completed 15 minute intervals.
virtualIfIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface Interval table."
::= { virtualIfStatistics 2 }
virtualIfIntervalEntry OBJECT-TYPE
SYNTAX VirtualIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface Interval table."
INDEX { ifIndex, virtualIfIntervalNumber }
::= { virtualIfIntervalTable 1 }
VirtualIfIntervalEntry ::=
SEQUENCE {
virtualIfIntervalNumber Integer32,
virtualIfIntervalMinActiveVC Integer32,
virtualIfIntervalMaxActiveVC Integer32,
virtualIfIntervalRxFrames Counter64,
virtualIfIntervalTxFrames Counter64,
virtualIfIntervalRxAbortFrames PerfIntervalCount,
virtualIfIntervalTxAbortFrames PerfIntervalCount,
virtualIfIntervalMinLengthViolation PerfIntervalCount,
virtualIfIntervalMaxLengthViolation PerfIntervalCount,
virtualIfIntervalFcsError PerfIntervalCount,
virtualIfIntervalByteDestuffingViolation PerfIntervalCount,
virtualIfIntervalAdressMismatch PerfIntervalCount,
virtualIfIntervalControlMismatch PerfIntervalCount,
virtualIfIntervalBelowMinThreshold PerfIntervalCount
}
virtualIfIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified by N-1."
::= { virtualIfIntervalEntry 1 }
virtualIfIntervalMinActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the minimum number of
active virtual containers (VCs) of the Virtual Concatenation Group, in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 2 }
virtualIfIntervalMaxActiveVC OBJECT-TYPE
SYNTAX Integer32 (1..64)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object holds the maximum number of
active virtual containers (VCs) of the Virtual Concatenation Group, in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 3 }
virtualIfIntervalRxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames received from STS-3/STM-1 by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 4 }
virtualIfIntervalTxFrames OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames transmitted to STS-3/STM-1 by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 5 }
virtualIfIntervalRxAbortFrames OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Received Abort frames encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= {virtualIfIntervalEntry 6 }
virtualIfIntervalTxAbortFrames OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Transmitted Abort frames encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 7 }
virtualIfIntervalMinLengthViolation OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Rx payload Min Length Violation frames
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 8 }
virtualIfIntervalMaxLengthViolation OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Rx payload Max Length Violation frames
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 9 }
virtualIfIntervalFcsError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Frame Check Sequence errors encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 10 }
virtualIfIntervalByteDestuffingViolation OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Byte De-stuffing Violations
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 11 }
virtualIfIntervalAdressMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Address Mismatch encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 12 }
virtualIfIntervalControlMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
Control mismatch encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 13 }
virtualIfIntervalBelowMinThreshold OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
seconds that number of active VCs was below minimum threshold
defined by vcGroupCnfgNoOfVCs,
encountered by Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfIntervalEntry 14 }
-- the Virtual Interface LAPS Current Table
virtualIfLAPSCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcGroupLAPSCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface LAPS Current table."
::= { virtualIfStatistics 3 }
virtualIfLAPSCurrentEntry OBJECT-TYPE
SYNTAX VcGroupLAPSCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
LAPS Current table."
INDEX { ifIndex }
::= { virtualIfLAPSCurrentTable 1 }
VcGroupLAPSCurrentEntry ::=
SEQUENCE {
virtualIfLAPSCurrentSapiMismatch PerfCurrentCount
}
virtualIfLAPSCurrentSapiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received SAPI field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPSCurrentEntry 1 }
-- the Virtual Interface LAPS Interval Table
-- The Virtual Interface LAPS Interval Table
-- contains various statistics collected over a maximum
-- of the previous 24 hours of operation.
-- The past 24 hours may be broken into 96
-- completed 15 minute intervals.
virtualIfLAPSIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfLAPSIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface LAPS table."
::= { virtualIfStatistics 4 }
virtualIfLAPSIntervalEntry OBJECT-TYPE
SYNTAX VirtualIfLAPSIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
LAPS Interval table."
INDEX { ifIndex, virtualIfIntervalNumber }
::= { virtualIfLAPSIntervalTable 1 }
VirtualIfLAPSIntervalEntry ::=
SEQUENCE {
virtualIfLAPSIntervalSapiMismatch PerfIntervalCount
}
virtualIfLAPSIntervalSapiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received SAPI field mismatch
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPSIntervalEntry 1 }
-- the Virtual Interface LAPF Current Table
virtualIfLAPFCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfLAPFCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface LAPF Current table."
::= { virtualIfStatistics 5 }
virtualIfLAPFCurrentEntry OBJECT-TYPE
SYNTAX VirtualIfLAPFCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
LAPF Current table."
INDEX { ifIndex }
::= { virtualIfLAPFCurrentTable 1 }
VirtualIfLAPFCurrentEntry ::=
SEQUENCE {
virtualIfLAPFCurrentNlpidMismatch PerfCurrentCount,
virtualIfLAPFCurrentOuiMismatch PerfCurrentCount,
virtualIfLAPFCurrentPidMismatch PerfCurrentCount,
virtualIfLAPFCurrentDlciMismatch PerfCurrentCount,
virtualIfLAPFCurrentMacRxFrames PerfCurrentCount,
virtualIfLAPFCurrentMacTxFrames PerfCurrentCount
}
virtualIfLAPFCurrentNlpidMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received NLPID field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 1 }
virtualIfLAPFCurrentOuiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received OUI field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 2 }
virtualIfLAPFCurrentPidMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received PID field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 3 }
virtualIfLAPFCurrentDlciMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received DLCI field mismatch
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 4 }
virtualIfLAPFCurrentMacRxFrames OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames received from LAN
by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 5 }
virtualIfLAPFCurrentMacTxFrames OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames transmitted to LAN
by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfLAPFCurrentEntry 6 }
-- the Virtual Interface LAPF Interval Table
-- The Virtual Interface LAPF Interval Table
-- contains various statistics collected over a maximum
-- of the previous 24 hours of operation.
-- The past 24 hours may be broken into 96
-- completed 15 minute intervals.
virtualIfLAPFIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfLAPFIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface LAPF Interval table."
::= { virtualIfStatistics 6 }
virtualIfLAPFIntervalEntry OBJECT-TYPE
SYNTAX VirtualIfLAPFIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface Interval table."
INDEX { ifIndex, virtualIfIntervalNumber }
::= { virtualIfLAPFIntervalTable 1 }
VirtualIfLAPFIntervalEntry ::=
SEQUENCE {
virtualIfLAPFIntervalNlpidMismatch PerfIntervalCount,
virtualIfLAPFIntervalOuiMismatch PerfIntervalCount,
virtualIfLAPFIntervalPidMismatch PerfIntervalCount,
virtualIfLAPFIntervalDlciMismatch PerfIntervalCount,
virtualIfLAPFIntervalMacRxFrames PerfIntervalCount,
virtualIfLAPFIntervalMacTxFrames PerfIntervalCount
}
virtualIfLAPFIntervalNlpidMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received NLPID field mismatch
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 1 }
virtualIfLAPFIntervalOuiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received OUI field mismatch
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 2 }
virtualIfLAPFIntervalPidMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received PID field mismatch
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 3 }
virtualIfLAPFIntervalDlciMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received DLCI field mismatch
by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 4 }
virtualIfLAPFIntervalMacRxFrames OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames received from LAN
by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 5 }
virtualIfLAPFIntervalMacTxFrames OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
frames transmitted to LAN
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfLAPFIntervalEntry 6 }
-- the Virtual Interface GFP Current Table
virtualIfGFPCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfGFPCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface GFP Current table."
::= { virtualIfStatistics 7 }
virtualIfGFPCurrentEntry OBJECT-TYPE
SYNTAX VirtualIfGFPCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
GFP Current table."
INDEX { ifIndex }
::= { virtualIfGFPCurrentTable 1 }
VirtualIfGFPCurrentEntry ::=
SEQUENCE {
virtualIfGFPCurrentIdleFrameError PerfCurrentCount,
virtualIfGFPCurrentCHecSbError PerfCurrentCount,
virtualIfGFPCurrentPtiMismatch PerfCurrentCount,
virtualIfGFPCurrentExiMismatch PerfCurrentCount,
virtualIfGFPCurrentUpiMismatch PerfCurrentCount,
virtualIfGFPCurrentTHecSbError PerfCurrentCount,
virtualIfGFPCurrentTHecMbError PerfCurrentCount,
virtualIfGFPCurrentCidMismatch PerfCurrentCount,
virtualIfGFPCurrentEHecSbError PerfCurrentCount,
virtualIfGFPCurrentEHecMbError PerfCurrentCount
}
virtualIfGFPCurrentIdleFrameError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP IDLE frames that are
detected to be in error,
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 1}
virtualIfGFPCurrentCHecSbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to have
single-bit errors in the Core
header (i.e. cHEC field) only,
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 2 }
virtualIfGFPCurrentPtiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
rreceived GFP frames that are detected with
a mismatch on the PTI field
(i.e. value of PTI is not equal to
Client Data or Management frame),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 3 }
virtualIfGFPCurrentExiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected with
a mismatch on the EXI field
(i.e. value of EXI is not equal
to NULL or LINEAR modes),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 4 }
virtualIfGFPCurrentUpiMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected with a
mismatch on the UPI field
(i.e. value of EXI is not equal to 00000001),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 5 }
virtualIfGFPCurrentTHecSbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected
to only have single-bit errors in the Type header
(i.e. tHEC field),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 6 }
virtualIfGFPCurrentTHecMbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to
only have multi-bit errors in the
Type header (i.e. tHEC field),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 7 }
virtualIfGFPCurrentCidMismatch OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to have a
mismatch/unsupported value in the CID field only,
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 8 }
virtualIfGFPCurrentEHecSbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected
to only have single-bit errors
in the Extension header (i.e. eHEC field),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 9 }
virtualIfGFPCurrentEHecMbError OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to only
have single-bit errors in the
Extension header (i.e. eHEC field),
encountered by a Virtual Interface
in the current 15-minute interval."
::= { virtualIfGFPCurrentEntry 10 }
-- the Virtual Interface GFP Interval Table
-- The Virtual Interface GFP Interval Table
-- contains various statistics collected over a maximum
-- of the previous 24 hours of operation.
-- The past 24 hours may be broken into 96
-- completed 15 minute intervals.
virtualIfGFPIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF VirtualIfGFPIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Interface GFP Interval table."
::= { virtualIfStatistics 8 }
virtualIfGFPIntervalEntry OBJECT-TYPE
SYNTAX VirtualIfGFPIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Interface
GFP Interval table."
INDEX { ifIndex, virtualIfIntervalNumber }
::= { virtualIfGFPIntervalTable 1 }
VirtualIfGFPIntervalEntry ::=
SEQUENCE {
virtualIfGFPIntervalIdleFrameError PerfIntervalCount,
virtualIfGFPIntervalCHecSbError PerfIntervalCount,
virtualIfGFPIntervalPtiMismatch PerfIntervalCount,
virtualIfGFPIntervalExiMismatch PerfIntervalCount,
virtualIfGFPIntervalUpiMismatch PerfIntervalCount,
virtualIfGFPIntervalTHecSbError PerfIntervalCount,
virtualIfGFPIntervalTHecMbError PerfIntervalCount,
virtualIfGFPIntervalCidMismatch PerfIntervalCount,
virtualIfGFPIntervalEHecSbError PerfIntervalCount,
virtualIfGFPIntervalEHecMbError PerfIntervalCount
}
virtualIfGFPIntervalIdleFrameError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP IDLE frames that are detected to be in error,
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 1 }
virtualIfGFPIntervalCHecSbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to have
single-bit errors in the Core header (i.e. cHEC field) only,
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 2 }
virtualIfGFPIntervalPtiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
rreceived GFP frames that are detected with
a mismatch on the PTI field (i.e. value of PTI
is not equal to Client Data or Management frame),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 3 }
virtualIfGFPIntervalExiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected with
a mismatch on the EXI field (i.e. value of EXI is not
equal to NULL or LINEAR modes),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 4 }
virtualIfGFPIntervalUpiMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected with a
mismatch on the UPI field (i.e. value of EXI
is not equal to 00000001),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 5 }
virtualIfGFPIntervalTHecSbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to only have
single-bit errors in the Type header (i.e. tHEC field),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 6 }
virtualIfGFPIntervalTHecMbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated withthe number of
received GFP frames that are detected to only have
multi-bit errors in the Type header (i.e. tHEC field),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 7 }
virtualIfGFPIntervalCidMismatch OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected to have a
mismatch/unsupported value in the CID field only,
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 8 }
virtualIfGFPIntervalEHecSbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the number of
received GFP frames that are detected
to only have single-bit errors
in the Extension header (i.e. eHEC field),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 9 }
virtualIfGFPIntervalEHecMbError OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This counter is associated with the the number of
received GFP frames that are detected to only have
multi-bit errors in the Extension header (i.e. eHEC field),
encountered by a Virtual Interface in a
particular 15-minute interval in the past 24 hours."
::= { virtualIfGFPIntervalEntry 10 }
prtSonetConfig OBJECT IDENTIFIER ::= {sonetInterface 2}
prtSonetGen OBJECT IDENTIFIER ::= {prtSonetConfig 1}
prtSonetGenTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet/SDH general port configuration table."
::= { prtSonetGen 1}
prtSonetGenEntry OBJECT-TYPE
SYNTAX PrtSonetGenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the Sonet/SDH general port configuration table."
INDEX { prtSonetGenCnfgIdx, prtSonetGenIdx }
::= { prtSonetGenTable 1}
PrtSonetGenEntry ::=
SEQUENCE {
prtSonetGenCnfgIdx
Integer32,
prtSonetGenIdx
Integer32,
prtSonetGenSdThreshold
INTEGER,
prtSonetGenEedThreshold
INTEGER,
prtSonetGenBerEnable
INTEGER
}
prtSonetGenCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetGenEntry 1}
prtSonetGenIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetGenEntry 2}
prtSonetGenSdThreshold OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
n3 (3),
n4 (4),
n5 (5),
n6 (6),
n7 (7),
n8 (8),
n9 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"SD=Signal Degraded Threshold. Units: [10E-].
The threshold is 10E-x relative to the frequency of the data flow.
x=3, 4, 5, 6, 7, 8, 9.
n3= 10E-3
n4= 10E-4
n5= 10E-5
n6= 10E-6
n7= 10E-7
n8= 10E-8
n9= 10E-9 ."
::= { prtSonetGenEntry 3 }
prtSonetGenEedThreshold OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
n3 (3),
n4 (4),
n5 (5),
n6 (6),
n7 (7),
n8 (8),
n9 (9)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"EED=Excessive Error Defect Threshold. Units: [10E-].
The threshold is 10E-x relative to the frequency of the data flow.
x=3, 4, 5, 6, 7, 8, 9.
n3= 10E-3
n4= 10E-4
n5= 10E-5
n6= 10E-6
n7= 10E-7
n8= 10E-8
n9= 10E-9 ."
::= { prtSonetGenEntry 4 }
prtSonetGenBerEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Controls the activation of the Line Ber (Bit Error Rate), means whether
SD and EED threshold parameters will be enabled."
::= { prtSonetGenEntry 5 }
--STM-1 ports
prtSonetStm1 OBJECT IDENTIFIER ::= {prtSonetConfig 2}
prtSonetStm1Table OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetStm1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet/SDH STM-1 port configuration table."
::= { prtSonetStm1 1}
prtSonetStm1Entry OBJECT-TYPE
SYNTAX PrtSonetStm1Entry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the Sonet/SDH STM-1 port configuration table."
INDEX { prtSonetStm1CnfgIdx, prtSonetStm1Idx }
::= { prtSonetStm1Table 1}
PrtSonetStm1Entry ::=
SEQUENCE {
prtSonetStm1CnfgIdx
Integer32,
prtSonetStm1Idx
Integer32,
prtSonetStm1ClockSrc
INTEGER,
prtSonetStm1DccMode
INTEGER,
prtSonetStm1RoutingProt
INTEGER,
prtSonetStm1MngProt
INTEGER,
prtSonetStm1OperationalMode
INTEGER,
prtSonetStm1VoiceChannel
INTEGER
}
prtSonetStm1CnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetStm1Entry 1}
prtSonetStm1Idx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetStm1Entry 2}
prtSonetStm1ClockSrc OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
internal (2),
lbt (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock Source of the STM-1 port.
lbt = Loop Back Timing."
::= { prtSonetStm1Entry 3 }
prtSonetStm1DccMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
none (2),
d1ToD3 (3),
d4ToD12 (4),
d1 (5),
d2 (6),
d3 (7),
d4 (8),
d5 (9),
d6 (10),
d7 (11),
d8 (12),
d9 (13),
d10 (14),
d11 (15),
d12 (16)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DCC Mode. DCC=Data Communication Channel.
d1ToD3 = D1-D3 bytes are used (RS=Regeneration Section).
d4ToD12= D4-D12 bytes are used (MS=Multiplexing Section).
d1.... d12 enable user to select single DCC byte "
::= { prtSonetStm1Entry 4 }
prtSonetStm1RoutingProt OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
none (2),
proprietary (3),
rip2 (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Routing Protocol."
::= { prtSonetStm1Entry 5 }
prtSonetStm1MngProt OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
-- none (2)
proprietary (3),
-- rip2 (4)
ppp (5),
frameRelay (6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Management Protocol over DCC: Proprietary, PPP or Frame Relay."
::= { prtSonetStm1Entry 6 }
prtSonetStm1OperationalMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
terminal (2),
linear (3),
linearProtection (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Operational Mode.
linear - cannot be selected when there is Redundancy between the
STM-1 ports."
::= { prtSonetStm1Entry 7 }
prtSonetStm1VoiceChannel OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
none (2),
e1Byte (3),
e2Byte (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter enable user to select whether
voice channel will be transferred using E1 byte, E2 Byte, or not at all."
::= { prtSonetStm1Entry 8 }
--SONET/SDH VC-3, VC-4 and VC-12 ports parameters
prtSonetVc OBJECT IDENTIFIER ::= {prtSonetConfig 3}
prtSonetVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Sonet/SDH VC port configuration table."
::= { prtSonetVc 1}
prtSonetVcEntry OBJECT-TYPE
SYNTAX PrtSonetVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
" An entry in the Sonet/SDH VC port configuration table."
INDEX { prtSonetVcCnfgIdx, prtSonetVcIdx }
::= { prtSonetVcTable 1}
PrtSonetVcEntry ::=
SEQUENCE {
prtSonetVcCnfgIdx
Integer32,
prtSonetVcIdx
Integer32,
prtSonetVcJTxPathTraceEnable
INTEGER,
prtSonetVcJRxPathTraceEnable
INTEGER,
prtSonetVcJPathTrace
DisplayString,
prtSonetVcConnect
INTEGER
}
prtSonetVcCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetVcEntry 1}
prtSonetVcIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetVcEntry 2}
prtSonetVcJTxPathTraceEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable Transmitting Jy Path Trace. y=1, 2:
J1 - for VC-4 layer
J2 - for VC-12 layer."
::= { prtSonetVcEntry 3 }
prtSonetVcJRxPathTraceEnable OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable checking Jy Path Trace. y=1, 2:
J1 - for VC-4 layer
J2 - for VC-12 layer."
::= { prtSonetVcEntry 4 }
prtSonetVcJPathTrace OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..16))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Jy Path Trace. y=1, 2:
J1 - for VC-4 layer
J2 - for VC-12 layer.
This object is applicable only if one of the previous 2 objects is 'enable'."
::= { prtSonetVcEntry 5 }
prtSonetVcConnect OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Connect VCn (n - 11,12,2,3,4) port (yes/no)."
::= { prtSonetVcEntry 6 }
--TU-12 (within VC-4) Connect Table
prtSonetTuTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetTuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table's Objects is valid only
for the TmpCnfg entry (Scratch)."
::= { prtSonetVc 2}
prtSonetTuEntry OBJECT-TYPE
SYNTAX PrtSonetTuEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {prtSonetTuCnfgIdx, prtSonetTuPrtIdx, prtSonetTuIdx, prtSonetTuConPrtIdx }
::= { prtSonetTuTable 1}
PrtSonetTuEntry ::=
SEQUENCE {
prtSonetTuCnfgIdx Integer32,
prtSonetTuPrtIdx Integer32,
prtSonetTuIdx Integer32,
prtSonetTuConPrtIdx Integer32,
prtSonetTuType INTEGER,
prtSonetTuMode INTEGER,
prtSonetTuRowStatus RowStatus
}
prtSonetTuCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetTuEntry 1}
prtSonetTuPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For port numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetTuEntry 2}
prtSonetTuIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique TU (Tributary Unit) within VC-4.
The valid TUs are 1..63."
::= { prtSonetTuEntry 3}
prtSonetTuConPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the connected port, when prtSonetTuType=connect.
For port numbering, see product's spec.
For some products, the numbering can equal ifIndex.
notApplicable - will be indicated as 100."
::= {prtSonetTuEntry 4}
prtSonetTuType OBJECT-TYPE
SYNTAX INTEGER
{
connect (2),
bypass (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of TU (Tributary Unit).
connect - connected to one of the E1 ports.
bypass - bypassed to the other VC4 port.
TUs that are not connected or bypassed, will not exist in this table."
::= { prtSonetTuEntry 5}
prtSonetTuMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
addAndDrop (2),
add (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"TU Mode of connection.
addAndDrop - Add & Drop
add - Add (TU receives from the E1 ports)."
::= { prtSonetTuEntry 6}
prtSonetTuRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { prtSonetTuEntry 7}
-- SDH Cross Connect Table
-- May be used also for SONET
prtSonetXConnect OBJECT IDENTIFIER ::= {sonetInterface 3}
prtSonetXConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrtSonetXConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The write operation into the Table's Objects is valid only
for the TmpCnfg entry (Scratch)."
::= { prtSonetXConnect 1}
prtSonetXConnectEntry OBJECT-TYPE
SYNTAX PrtSonetXConnectEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {
prtSonetXConnectCnfgIdx,
prtSonetXConnectPrtIdx,
prtSonetXConnectConPrtIdx,
prtSonetXConnectAUGIdx,
prtSonetXConnectTUG3Idx,
prtSonetXConnectTUG2Idx,
prtSonetXConnectTUnIdx
}
::= { prtSonetXConnectTable 1}
PrtSonetXConnectEntry ::=
SEQUENCE {
prtSonetXConnectCnfgIdx Integer32,
prtSonetXConnectPrtIdx Integer32,
prtSonetXConnectConPrtIdx Integer32,
prtSonetXConnectAUGIdx Integer32,
prtSonetXConnectTUG3Idx Integer32,
prtSonetXConnectTUG2Idx Integer32,
prtSonetXConnectTUnIdx Integer32,
prtSonetXConnectRowStatus RowStatus,
prtSonetXConnectDirection INTEGER,
prtSonetXConnectTuNumber INTEGER
}
prtSonetXConnectCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { prtSonetXConnectEntry 1}
prtSonetXConnectPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique port or interface number.
For port numbering, see product's spec.
For some products, the numbering can equal ifIndex."
::= { prtSonetXConnectEntry 2}
prtSonetXConnectConPrtIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the connected port.
For port numbering, see product's spec.
For some products, the numbering can equal ifIndex.
notApplicable - will be indicated as 255."
::= {prtSonetXConnectEntry 3}
prtSonetXConnectAUGIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates an AUG (Administrative Unit Group) within STM-N.
The valid AUGs values are:
1 for STM-1
1...4 for STM-4,
1..16 for STM-16 and
1..64 for STM-64 (STM-64)
255 designates NA."
::= { prtSonetXConnectEntry 4}
prtSonetXConnectTUG3Idx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a TUG-3 (Tributary Unit Group 3) within VC-4.
The valid TUG3s are values are 1..3. and 255 which designates NA "
::= { prtSonetXConnectEntry 5}
prtSonetXConnectTUG2Idx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a TUG2 (Tributary Unit Group 2 ) within VC-3.
The valid TUG2's values are 1..7 and 255 which designates NA "
::= { prtSonetXConnectEntry 6}
prtSonetXConnectTUnIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a TUn within TUG-2 or TUG-3
(Tributary Unit n, where n is 2, 12 or 11 within TUG-2,
or 3 within TUG-3)
valid values are
1 for TU-2
1 for TU-3
1..4 for TU-11
1..3 for TU-12
255 designates NA"
::= { prtSonetXConnectEntry 7}
prtSonetXConnectRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { prtSonetXConnectEntry 8}
prtSonetXConnectDirection OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
rx (2),
tx (3),
both (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"TU direction of connection.
rx=Drop
tx=Add
both = Add & Drop "
::= { prtSonetXConnectEntry 9}
prtSonetXConnectTuNumber OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
tu2 (2),
tu3 (3),
tu11 (4),
tu12 (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates which TU is used in prtSonetXConnectTUnIdx "
::= { prtSonetXConnectEntry 10}
prtVcGroupCnfg OBJECT IDENTIFIER ::= {prtSonetConfig 4}
vcGroupCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcGroupCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Concatenation Group configuration table."
::= { prtVcGroupCnfg 1 }
vcGroupCnfgEntry OBJECT-TYPE
SYNTAX VcGroupCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Concatenation Group
configuration table."
INDEX { vcGroupCnfgIdx,vcGroupCnfgNumber}
::= { vcGroupCnfgTable 1 }
VcGroupCnfgEntry ::=
SEQUENCE {
vcGroupCnfgIdx Integer32,
vcGroupCnfgNumber Integer32,
vcGroupCnfgRowStatus RowStatus,
vcGroupCnfgVcType INTEGER,
vcGroupCnfgNoOfVCs Integer32,
vcGroupCnfgLCAS INTEGER,
vcGroupCnfgEncapsulation INTEGER,
vcGroupCnfgGroupIfIndex InterfaceIndex,
vcGroupCnfgRip2 INTEGER,
vcGroupCnfgGfpChId Integer32
}
vcGroupCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Idx of the Config being accessed.
Idx of 255 relates to the Temporary (Scratch) Config.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { vcGroupCnfgEntry 1}
vcGroupCnfgNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Virtual Concatenation Group Number.
For FCD=155 up to four groups are defined
valid values are 1..4"
::= { vcGroupCnfgEntry 2}
vcGroupCnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { vcGroupCnfgEntry 3}
vcGroupCnfgVcType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
vc12 (2), --SDH
vc3 (3), --SDH
vc4 (4), --SDH
vt1dot5 (5), --SONET VT1.5
sts1 (6) --SONET STS-1 /SPE
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User may select type of SDH Virtual Containers (VC)
(SONET Virtual Tributaries VT ) to be concatenated
in this Virtual Concatenation Group.
For SDH, values 2,3,4 are valid.
For SONET, values 5 and 6 are valid."
::= { vcGroupCnfgEntry 4}
vcGroupCnfgNoOfVCs OBJECT-TYPE
SYNTAX Integer32 (0..84)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"User may select number of Virtual Containers (VC)
(SONET Virtual Tributaries VT ) to be concatenated
in this Virtual Concatenation Group.
Valid range for this number depends on
type VC selected by vcGroupCnfgVCType
For SDH, up to 63 VC12, or
up to 3 VC3, or
1 VC4 are valid
For SONET, up to 84 VT1.5 without LCAS,
or 64 VT1.5 under LCAS control.
or up tp 3 STS-1/SPE, or
1 STS-3"
::= { vcGroupCnfgEntry 5}
vcGroupCnfgLCAS OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
lcasNotActive (2),
lcasActive (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls Link Capacity Adjustment
Scheme (LCAS) activation."
::= { vcGroupCnfgEntry 6}
vcGroupCnfgEncapsulation OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
laps (2), -- Link access protocol S
lapf (3), -- Link access protocol F (Frame relay)
gfp (4) -- Generic Framing Procedure
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables user to select encapsulation method."
::= { vcGroupCnfgEntry 7}
vcGroupCnfgGroupIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ifIndex assigend to this group."
::= { vcGroupCnfgEntry 8}
vcGroupCnfgRip2 OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object controls RIP 2.
User may select to send RIP 2 message over
selected group or not"
::= { vcGroupCnfgEntry 9}
vcGroupCnfgGfpChId OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Generic Framing Procedure (GFP) Channel ID,
Valid only when vcGroupCnfgEncapsulation = gfp (4)
Valid values are 0x00 - oxFF (hex) "
::= { vcGroupCnfgEntry 10}
vcgGfpMuxCnfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF VcgGfpMuxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Virtual Concatenation Group GFP Mux configuration table."
::= { prtVcGroupCnfg 2 }
-- This table defines multiplexing scheme for GFP mux of
-- Virtual Concatenation Groups:
-- Primary group, Secondary group/s and bandwidth allocation
-- to each group.
vcgGfpMuxCnfgEntry OBJECT-TYPE
SYNTAX VcgGfpMuxCnfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Virtual Concatenation Group GFP Mux
configuration table."
INDEX { vcgGfpMuxCnfgIdx,vcgGfpMuxCnfgMuxNumber}
::= { vcgGfpMuxCnfgTable 1 }
VcgGfpMuxCnfgEntry ::=
SEQUENCE {
vcgGfpMuxCnfgIdx Integer32,
vcgGfpMuxCnfgMuxNumber Integer32,
vcgGfpMuxCnfgRowStatus RowStatus,
vcgGfpMuxCnfgMuxName SnmpAdminString,
vcgGfpMuxCnfgPrimeGroup Integer32,
vcgGfpMuxCnfgGrpBwAlloc OCTET STRING
}
vcgGfpMuxCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object indicates the Index of the configuration being accessed.
Index of 255 relates to the Temporary (Scratch) coninguration.
For products that support several configurations, Set can be performed
only to the Temporary Config (=255). "
::= { vcgGfpMuxCnfgEntry 1}
vcgGfpMuxCnfgMuxNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Virtual Concatenation Group GFP Mux Number.
For FCD=155 up to 2 GFP muxes can be created."
::= { vcgGfpMuxCnfgEntry 2}
vcgGfpMuxCnfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { vcgGfpMuxCnfgEntry 3}
vcgGfpMuxCnfgMuxName OBJECT-TYPE
SYNTAX SnmpAdminString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Virtual Concatenation Group, GFP Mux name."
::= { vcgGfpMuxCnfgEntry 4}
vcgGfpMuxCnfgPrimeGroup OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Index of Virtual Concatenation Group used as
Primary for the GFP mux created
for FCD 155 four Virtual Concatenation Group are defined:
1 -> Virtual Concatenation Group 1
2 -> Virtual Concatenation Group 2
3 -> Virtual Concatenation Group 3
4 -> Virtual Concatenation Group 4"
::= { vcgGfpMuxCnfgEntry 5}
vcgGfpMuxCnfgGrpBwAlloc OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the allocated bandwidth (BW) to each
Virtual Concatenation Group (VCG).
Each nibble indicates BW percentage, in 12.5% steps,
assigned to a group.
For FCD-155, there are 4 VCGs.
One VCG is identified as primary group by vcGfpMuxConfPrimeGroup.
Other VCGs may be secondaries.
VCG with allocated BW value of zero does not belong to the GFPmux
defined by GFP Mux number.
________________________________________
| Octet 0 | Octet 1 |
|Nibble 4 Nibble 3| Nibble 2| Nibble 1|
MSB | 7 6 5 4 | 3 2 1 0 | 7 6 5 4 | 3 2 1 0 | LSB
VCG1 VCG2 VCG 3 VCG4
Nibble value - BW Percentage
(0...7) (0 ...87.5%)
1 0001 12.5 %
2 0010 25%
3 0011 37.5
.....
7 0111 87.5%
at least one nibble must be greater that zero.
Sum of alloacted BW must be 100%.
Primary VCG BW must be greater than zero."
::= { vcgGfpMuxCnfgEntry 6}
-- END--
-- file :v:\doc\rdv\mib\ver495\atm\NtePrtCo.txt
--
-- *************************
-- file : NtePrtConfg.txt
--
--Version: 1.0
--Date: 12.11.97
--By: Ilana Schvetz
--File: v:\doc\rdv\mib\ver495\atm\NtePrtConfg.txt
--Last Update: 15-Feb-04 by Yig'al Hachmon (back to original 495)
-- Copyright 1997 RAD Data Communications, Ltd.
-- All Rights Reserved.
atmNte OBJECT IDENTIFIER ::= { radAtm 3 }
atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 }
atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 }
atmNteEvents OBJECT-IDENTITY
STATUS current
DESCRIPTION
"The events for RAD ATM products."
::= { atmNte 0 }
atmNteConfIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteConfIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Physical interface configuration table."
::= { atmNtePrtConfig 1 }
atmNteConfIfEntry OBJECT-TYPE
SYNTAX AtmNteConfIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Physical interface configuration table.
The ifIndex is of the lowest physical layer."
INDEX { ifIndex}
::= { atmNteConfIfTable 1 }
AtmNteConfIfEntry ::=
SEQUENCE {
atmConfIfTransmitClk
INTEGER,
atmConfIfLoopback
INTEGER,
atmConfIfFrameType
INTEGER,
atmConfIfCardType
INTEGER,
atmConfAtmIfVpiVciLimit
INTEGER,
atmConfIfHwFeatures
INTEGER,
atmConfIfOutputRate
Integer32,
atmConfIfInputRate
Integer32,
atmConfAlarmForwarding
INTEGER,
atmConfIfAllocatedBw
Integer32,
atmConfIfLowerVpi
Integer32,
atmConfIfOamMode
INTEGER
}
atmConfIfTransmitClk OBJECT-TYPE
SYNTAX INTEGER { internal(2), external(3), loopback(4), adaptive(5) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The transmit clock of the port."
::= { atmNteConfIfEntry 1 }
atmConfIfLoopback OBJECT-TYPE
SYNTAX INTEGER { internal(2), external(3), disable(4) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Interface Loopback."
::= { atmNteConfIfEntry 2 }
atmConfIfFrameType OBJECT-TYPE
SYNTAX INTEGER {
other (1),
sonet (2),
sdh (3),
direct (4),
plcpInternal (5),
plcpExternal (6),
e3 (7),
ethCrcTrans (8),
ethCrcNotTrans (9),
directNoScrmbling (10),
plcpInternalNoScrmbling (11),
plcpExternalNoScrmbling (12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The frame type. Valid values for a 155M interface:
sonet(2), sdh(3). Valid values for a T3 interface:
direct(4), plcpInternal(5), plcpExternal(6),
directNoScrmbling(10), plcpInternalNoScrmbling(11),
plcpExternalNoScrmbling(12). Valid values for Ethernet
interface: ethCrcTrans (8), ethCrcNotTrans(9).
(DS1 interfaces frame type is specified in the DSX1 mib)."
::= { atmNteConfIfEntry 3 }
atmConfIfCardType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
sc13m-155(2),
st13s-155(3),
st13l-155(4),
utp-155(5),
cx-bnc-155(6),
e3(7),
t3(8),
e1(9),
e1-ltu(10),
fc13l-155(11),
fc13lh-155(12),
fc15lh-155(13),
fc13l-e3(14),
fc13lh-e3(15),
fc15lh-e3(16),
fc13l-t3(17),
fc13lh-t3(18),
fc15lh-t3(19)
}
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION
"The card type."
::= { atmNteConfIfEntry 4 }
atmConfAtmIfVpiVciLimit OBJECT-TYPE
SYNTAX INTEGER {
bits15(2),
bits17(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The limit on the sum of the VPI+VCI bits for this interface."
::= { atmNteConfIfEntry 5 }
atmConfIfHwFeatures OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"HW features command."
::= { atmNteConfIfEntry 6 }
atmConfIfOutputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the output rate in cells/sec, which is
supported per port. Successfully setting this parameter
is dependent on all other ports values calculations,
which are described in the NMS SRS."
::= { atmNteConfIfEntry 7 }
atmConfIfInputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter indicates the input rate in cells/sec, which is
supported per port. Successfully setting this parameter
is dependent on all other ports values calculations,
which are described in the NMS SRS."
::= { atmNteConfIfEntry 8 }
atmConfAlarmForwarding OBJECT-TYPE
SYNTAX INTEGER { disable(2), enable(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enables Path AIS Alarm forwarding upon a failure detection. The
following might be considered as a failure: LOS, LOF, LOC, SLM,
LOP, Path AIS and Line AIS.
disable(2) - will not forward an alarm upon a failure on this port.
enable(3) - will forward an alarm upon a failure on this port."
::= { atmNteConfIfEntry 9 }
atmConfIfAllocatedBw OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total VC Bandwidth Allocation."
::= { atmNteConfIfEntry 10 }
atmConfIfLowerVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Lower possible VPI."
::= { atmNteConfIfEntry 11 }
atmConfIfOamMode OBJECT-TYPE
SYNTAX INTEGER {
-- intermediate(1),
segmentTermination(2),
endToEndTermination(3)
-- vpEndToEndVcSegment(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM support Mode, which determines the
interface's location in a segment wise."
::= { atmNteConfIfEntry 12 }
atmNteAlarmIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteAlarmIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The interface Alarm table."
::= { atmNtePrtConfig 2 }
atmNteAlarmIfEntry OBJECT-TYPE
SYNTAX AtmNteAlarmIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the interface Alarm table."
INDEX { ifIndex}
::= { atmNteAlarmIfTable 1 }
AtmNteAlarmIfEntry ::=
SEQUENCE {
atmInterfaceActiveAlarms
Integer32,
atmThresholdSectionBIP
Integer32,
atmThresholdLineBIP
Integer32,
atmThresholdLineFEBE
Integer32,
atmThresholdPathBIP
Integer32,
atmThresholdPathFEBE
Integer32,
atmThresholdErroredCells
Integer32,
atmThresholdLostCells
Integer32,
atmThresholdMisinsertedCells
Integer32,
atmInterfaceAlarmStatus
INTEGER,
atmInterfaceMaskAlarms
Integer32
}
atmInterfaceActiveAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bit String of the active alarms on this interface.
An up bit (1) means there is an active alarm of this
type. A down bit (0) means there is no such alarm.
The meaning of the bits is as follows:
1 - LOS
2 - LOF
3 - Line AIS (SONET)/ PLCP LOF (DS3)
4 - LOP
5 - Path AIS
6 - SLM
7 - LCD
8 - Line RDI (SONET)/ PLCP Yellow (DS3)
9 - Path RDI (SONET)/ RDI (DS3)
10 - Section BIP (SONET)/ P1/P2 (DS3) > Threshold
11 - Line BIP (SONET)/ PLCP BIP (DS3) > Threshold
12 - Line FEBE (SONET)/ PLCP FEBE (DS3) > Threshold
13 - Path BIP > Threshold
14 - Path FEBE > Threshold
15 - HW Failure
"
::= { atmNteAlarmIfEntry 1 }
atmThresholdSectionBIP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Section BIPs are greater than this threshold,
an active alarm is raised. N/A for ds3/e3 interface."
::= { atmNteAlarmIfEntry 2 }
atmThresholdLineBIP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Line BIPs are greater than this threshold,
an active alarm is raised. N/A for ds3/e3 interface."
::= { atmNteAlarmIfEntry 3 }
atmThresholdLineFEBE OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Line FEBEs are greater than this threshold,
an active alarm is raised. N/A for ds3/e3 interface."
::= { atmNteAlarmIfEntry 4 }
atmThresholdPathBIP OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Path BIPs are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 5 }
atmThresholdPathFEBE OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Path FEBEs are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 6 }
atmThresholdErroredCells OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Errored Cells are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 7 }
atmThresholdLostCells OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Lost Cells are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 8 }
atmThresholdMisinsertedCells OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When Misinserted Cells are greater than this threshold,
an active alarm is raised."
::= { atmNteAlarmIfEntry 9 }
atmInterfaceAlarmStatus OBJECT-TYPE
SYNTAX INTEGER { off(2),
on(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The variable is on(3) when there is any active alarm
on this interface."
::= { atmNteAlarmIfEntry 10 }
atmInterfaceMaskAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A Bit String of alarms mask on this interface.
An up bit (1) means that the respective alarm is masked.
A down bit (0) means no mask.
The mask is supported for the following alarms:
1 - LOS
"
::= { atmNteAlarmIfEntry 11 }
atmNteConfVpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteConfVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP configuration table.
The table is an extension to the atmVplTable of
RFC-1695."
::= { atmNtePrtConfig 3 }
atmNteConfVpEntry OBJECT-TYPE
SYNTAX AtmNteConfVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP configuration table.
ifIndex of the ATM layer."
INDEX { ifIndex, atmVplVpi }
::= { atmNteConfVpTable 1 }
AtmNteConfVpEntry ::=
SEQUENCE {
atmConfVpPolicing INTEGER,
atmConfVpCCAdminStatus INTEGER,
atmConfVpLoopbackAdminStatus INTEGER,
atmConfVpLoopbackSinkAddress OCTET STRING,
atmConfVpCongestionControl OCTET STRING,
atmConfVpCCDirection INTEGER,
atmConfVpCreationTime DateAndTime,
atmConfVpOamSupport INTEGER,
atmConfVpCCOperStatus INTEGER,
atmConfVpLoopbackTraffic INTEGER,
atmConfVpLoopbackFailureInd INTEGER,
atmConfVpLoopbackFailureThreshold Integer32,
atmConfVpOamDirection INTEGER
}
atmConfVpPolicing OBJECT-TYPE
SYNTAX INTEGER {
none(1),
police(2),
monitor(3),
shaping(4),
policingAndShaping(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Policing method desired for this VPL."
::= { atmNteConfVpEntry 1 }
atmConfVpCCAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up (2),
down (3),
source(4), -- agent send Oam CC cells
sink (5), -- agent check received Oam CC cells
listenToActivationCells (6),
originateActivationCells(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"up(2) - Activate Continuity Check (CC).
down(3) - Deactivate CC.
source(4) - Activate OAM CC(Continuity Check) of local agent
( start sending Oam cells to the remote side ).
sink(5) - Activate CC of remote agent ( start receiving Oam cells from
remote side ).
listenToActivationCells (6) - Passive listener till gets an activation request
originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection."
::= {atmNteConfVpEntry 2}
atmConfVpLoopbackAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(2),
down(3),
llid(4),
segment(5),
endToEnd(6),
segmentLlid(7),
endToEndLlid(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"up(2) - Start loopback OAM cells.
down(3) - Stop sending loopback OAM cells.
For ace2002:
up(2) - Transmitting LB cells with llid all ones
(i.e. FFFF..FF)
down(3) - Not transmitting LB cells.
llid(4) - Transmitting LB cells with llid indicated
in the address field.
segment(5) - Transmitting Segment LB cells with llid
all ones.
endToEnd(6) - Transmitting End to End LB cells with llid
all ones.
segmentLlid(7) - Transmitting Segment LB cells with
llid indicated in the address field.
endToEndLlid(8) - Transmitting LB cells with llid
indicated in the address field.
This parameter value might be in conflict with
atmConfVpOamSupport value, since this parameter is for LB,
while atmConfVpOamSupport is for any other OAM cells."
::= {atmNteConfVpEntry 3}
atmConfVpLoopbackSinkAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination address.
For ace101: 2 bytes are used.
For ace2002: 16 bytes are used."
::= {atmNteConfVpEntry 4}
atmConfVpCongestionControl OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Each bit indicates a selection of one option
as the following description. All combinations
are possible and legal.
The codes are:
1 - EPD
2 - CLP
4 - EFCI"
::= {atmNteConfVpEntry 5}
atmConfVpCCDirection OBJECT-TYPE
SYNTAX INTEGER {
both (2),
source(4),
sink (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"both(2) - Agent send OAM CC cells and check received OAM CC cells
source(4)- Agent send OAM CC cells.
sink(5) - Agent checks received OAM CC cells."
::= {atmNteConfVpEntry 6}
atmConfVpCreationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A date-time in which the VP was created."
::= { atmNteConfVpEntry 7 }
atmConfVpOamSupport OBJECT-TYPE
SYNTAX INTEGER {
intermediate(1),
segmentTermination(2),
endToEndTermination(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM support mode, which determines the device location
in a segment wise."
::= { atmNteConfVpEntry 8 }
atmConfVpCCOperStatus OBJECT-TYPE
SYNTAX INTEGER {
initial (1),
source(4),
sink (5),
both (8),
timeout (9),
denied (10),
conflict (11),
manual (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"
initial(1) - The CC activation process is not started.
source(4) - Agent sends OAM CC cells.
sink(5) - Agent checks received OAM CC cells.
both (8) - OAM CC of local and remote agents activation.
timeout (9) - Timeout occured on receiving answer from
the remote agent.
denied (10) - CC activation process rejected by remote agent.
conflict (11) - local and remote sides requested activation
simultaneously.
manual (12) - OAM CC of local agent activated manually.
"
::= {atmNteConfVpEntry 9}
atmConfVpLoopbackTraffic OBJECT-TYPE
SYNTAX INTEGER { off(2), on(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter has both command and status meanings:
off(2) - Set to 'Off' will Stop traffic loop. Getting this
value means that the loop is not running.
on (3) - Set to 'On' will start traffic loop. Getting
this value means that the loop is currently running."
::= {atmNteConfVpEntry 10}
atmConfVpLoopbackFailureInd OBJECT-TYPE
SYNTAX INTEGER {
disabled(2),
segmentAis(3),
segmentRdi(4),
segmentAisAndRdi(5),
endToEndAis(6),
endToEndRdi(7),
endToEndAisAndRdi(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows user to define the Indication that will be created upon
a LB cell failure.
disabled(2) - no indication will be created.
segmentAis(3) - will cause Tx of a segment AIS.
segmentRdi(4) - will cause Tx of a segment RDI.
segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI.
endToEndAis(6) - will cause Tx of an End to End AIS.
endToEndRdi(7) - will cause Tx of an End to End RDI.
endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI.
Default: disabled(2)."
::= {atmNteConfVpEntry 11}
atmConfVpLoopbackFailureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the LB failures before starting transmission of the
Indication defined by atmConfVcLoopbackFailureInd.
Range: 1..16. Default: 1."
::= {atmNteConfVpEntry 12}
atmConfVpOamDirection OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
downStream (2),
upStream (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The direction of OAM cell insertion.
downStream(2) - The OAM cell will be inserted in downStream.
upStream(3) - The OAM cell will be inserted in upStream."
::= {atmNteConfVpEntry 13}
--Alarm Table
atmNteAlarmVpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteAlarmVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP Alarm table."
::= { atmNtePrtConfig 5 }
atmNteAlarmVpEntry OBJECT-TYPE
SYNTAX AtmNteAlarmVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP Alarm table.
ifIndex of the ATM layer."
INDEX { ifIndex, atmNteVpAlarmVpi}
::= { atmNteAlarmVpTable 1 }
AtmNteAlarmVpEntry ::=
SEQUENCE {
atmNteVpAlarmVpi
Integer32,
atmNteVpActiveAlarms
Integer32
}
atmNteVpAlarmVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI on which there is an active alarm."
::= { atmNteAlarmVpEntry 1 }
atmNteVpActiveAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bit String of the active alarms on this VP.
An up bit (1) means there is an active alarm of this
type. A down bit (0) means there is no such alarm.
The meaning of the bits is as follows:
1 - VP AIS
2 - VP Loss Of Continuity
3 - VP RDI Reception
4 - VP Errored Cells > Threshold
5 - VP Lost Cells > Threshold
6 - VP Misinserted Cells > Threshold
9 - VP Loopback Failure
"
::= { atmNteAlarmVpEntry 2 }
atmNteAlarmVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteAlarmVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC Alarm table."
::= { atmNtePrtConfig 6 }
atmNteAlarmVcEntry OBJECT-TYPE
SYNTAX AtmNteAlarmVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC Alarm table.
ifIndex of the ATM layer."
INDEX { ifIndex, atmNteVcAlarmVpi, atmNteVcAlarmVci}
::= { atmNteAlarmVcTable 1 }
AtmNteAlarmVcEntry ::=
SEQUENCE {
atmNteVcAlarmVpi
Integer32,
atmNteVcAlarmVci
Integer32,
atmNteVcActiveAlarms
Integer32
}
atmNteVcAlarmVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VC on which there is an active alarm."
::= { atmNteAlarmVcEntry 1 }
atmNteVcAlarmVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VC on which there is an active alarm."
::= { atmNteAlarmVcEntry 2 }
atmNteVcActiveAlarms OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A Bit String of the active alarms on this VC.
An up bit (1) means there is an active alarm of this
type. A down bit (0) means there is no such alarm.
The meaning of the bits is as follows:
1 - VC AIS
2 - VC Loss Of Continuity
3 - VC RDI
4 - VC Errored Cells > Threshold
5 - VC Lost Cells > Threshold
6 - VC Misinserted Cells > Threshold
7 - Tx VC AIS
8 - Tx VC RDI
9 - VC Loopback Failure
"
::= { atmNteAlarmVcEntry 3 }
--
-- file :v:\doc\rdv\mib\ver495\atm\confVcTa.txt
--
-- file : ConfVcTable.txt
--
--Version: 1.0
--Date: 12.11.97
--By: Ilana Schvetz
--File: v:\doc\rdv\mib\ver495\atm\ConfVcTable.txt
--Last Update: 15-Dec-02 by Shay Harari.
-- *******************************************************
-- Configuration Vc Table
-- *******************************************************
--atmNte OBJECT IDENTIFIER ::= { radAtm 3 }
--atmNtePrt OBJECT IDENTIFIER ::= { atmNte 2 }
--atmNtePrtConfig OBJECT IDENTIFIER ::= { atmNtePrt 1 }
atmNteConfVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteConfVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC configuration table.
The table is an extension to the atmVclTable of
RFC-1695."
::= { atmNtePrtConfig 4 }
atmNteConfVcEntry OBJECT-TYPE
SYNTAX AtmNteConfVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC configuration table.
ifIndex of the ATM layer."
INDEX { ifIndex , atmVclVpi, atmVclVci}
::= { atmNteConfVcTable 1 }
AtmNteConfVcEntry ::=
SEQUENCE {
atmConfVcPolicing INTEGER,
atmConfVcCCAdminStatus INTEGER,
atmConfVcLoopbackAdminStatus INTEGER,
atmConfVcLoopbackSinkAddress OCTET STRING,
atmConfVcCongestionControl OCTET STRING,
atmConfVcCCDirection INTEGER,
atmConfVcCreationTime DateAndTime,
atmConfVcOamSupport INTEGER,
atmConfVcCCActivationCtrl INTEGER,
atmConfVcCCOperStatus INTEGER,
atmConfVcLoopbackTraffic INTEGER,
atmConfVcLoopbackFailureInd INTEGER,
atmConfVcLoopbackFailureThreshold Integer32,
atmConfVcOamDirection INTEGER,
atmConfVcName DisplayString,
atmConfVcConnected INTEGER
}
atmConfVcPolicing OBJECT-TYPE
SYNTAX INTEGER {
none(1),
police(2),
monitor(3),
shaping(4),
policingAndShaping(5),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Policing method desired for this VCL."
::= { atmNteConfVcEntry 1 }
atmConfVcCCAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(2),
down(3),
source(4), -- agent send Oam CC cells
sink(5), -- agent check received Oam CC cells
listenToActivationCells (6),
originateActivationCells(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"up(2) - Activate Continuity Check (CC).
down(3) - Deactivate CC.
source(4) - Activate OAM CC(Continuity Check) of local agent
( start sending Oam cells to the remote side ).
sink(5) - Activate CC of remote agent ( start receiving Oam cells from
remote side).
listenToActivationCells (6) - Passive listener till gets an activation request
originateActivationCells(7) - Sands Activation cell according to atmConfVcCCDirection."
::= {atmNteConfVcEntry 2}
atmConfVcLoopbackAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up(2),
down(3),
llid(4),
segment(5),
endToEnd(6),
segmentLlid(7),
endToEndLlid(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"up(2) - Start loopback OAM cells.
down(3) - Stop sending loopback OAM cells.
For ace2002:
up(2) - Transmitting LB cells with llid all ones
(i.e. FFFF..FF)
down(3) - Not transmitting LB cells.
llid(4) - Transmitting LB cells with llid indicated
in the address field.
segment(5) - Transmitting Segment LB cells with llid
all ones.
endToEnd(6) - Transmitting End to End LB cells with llid
all ones.
segmentLlid(7) - Transmitting Segment LB cells with
llid indicated in the address field.
endToEndLlid(8) - Transmitting LB cells with llid
indicated in the address field.
This parameter value might be in conflict with
atmConfVcOamSupport value, since this parameter is for LB,
while atmConfVcOamSupport is for any other OAM cells."
::= {atmNteConfVcEntry 3}
atmConfVcLoopbackSinkAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination address.
For ace101: 2 bytes are used.
For ace2002: 16 bytes are used."
::= {atmNteConfVcEntry 4}
atmConfVcCongestionControl OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Each bit indicates a selection of one option
as the following description. All combinations
are possible and legal.
The codes are:
1 - EPD
2 - CLP
4 - EFCI.
For ace2002:
1 - Packet Discard."
::= {atmNteConfVcEntry 5}
atmConfVcCCDirection OBJECT-TYPE
SYNTAX INTEGER {
both (2),
none (3),
source(4),
sink (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"both(2) - Agent send OAM CC cells and check receivev OAM CC cells
none(3) - Agent does not send and does not check received OAM CC cells.
source(4)- Agent send OAM CC cells.
sink(5) - Agent checks received OAM CC cells."
::= {atmNteConfVcEntry 6}
atmConfVcCreationTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A date-time in which the VC was created."
::= { atmNteConfVcEntry 7 }
atmConfVcOamSupport OBJECT-TYPE
SYNTAX INTEGER {
intermediate(1),
segmentTermination(2),
endToEndTermination(3),
segmentAndEndToEnd(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM support mode, which determines the device location
in a segment wise.
segmentAndEndToEnd - In this mode the OAM cells are generated
before the ABM (ATM Buffer Manager), so
that the PCR and CDVT will not be affected."
::= { atmNteConfVcEntry 8 }
atmConfVcCCActivationCtrl OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
activator(2),
listener(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"manual(1) - CC Activation process is disable
activator(2) - ACE-101 initiate CC Activation process
listener(3) - ACE-101 wait to CC Activation request from remote side."
::= { atmNteConfVcEntry 9 }
atmConfVcCCOperStatus OBJECT-TYPE
SYNTAX INTEGER {
initial(1),
up(2),
down(3),
source(4), -- agent send Oam CC cells
sink(5), -- agent check received Oam CC cells
both (8),
timeout (9),
denied (10),
conflict (11),
manual (12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"initial (1) - The CC activation process is not started.
up (2) - Continuity Check (CC) activated.
down (3) - CC deactivated.
source (4) - OAM CC(Continuity Check) of local agent activated.
sink (5) - OAM CC of remote agent activated.
both (8) - OAM CC of local and remote agents activation.
timeout (9) - Timeout occured on receiving answer from
the remote agent.
denied (10) - CC activation process rejected by remote agent.
conflict (11) - local and remote sides requested activation
simultaneously.
manual (12) - OAM CC of local agent activated manually.
"
::= { atmNteConfVcEntry 10 }
atmConfVcLoopbackTraffic OBJECT-TYPE
SYNTAX INTEGER { off(2), on(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter has both command and status meanings:
off(2) - Set to 'Off' will Stop traffic loop. Getting this
value means that the loop is not running.
on (3) - Set to 'On' will start traffic loop. Getting
this value means that the loop is currently running."
::= {atmNteConfVcEntry 11}
atmConfVcLoopbackFailureInd OBJECT-TYPE
SYNTAX INTEGER {
disabled(2),
segmentAis(3),
segmentRdi(4),
segmentAisAndRdi(5),
endToEndAis(6),
endToEndRdi(7),
endToEndAisAndRdi(8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows user to define the Indication that will be created upon
a LB cell failure.
disabled(2) - no indication will be created.
segmentAis(3) - will cause Tx of a segment AIS.
segmentRdi(4) - will cause Tx of a segment RDI.
segmentAisAndRdi(5) - will cause Tx of a segment AIS & RDI.
endToEndAis(6) - will cause Tx of an End to End AIS.
endToEndRdi(7) - will cause Tx of an End to End RDI.
endToEndAisAndRdi(8) - will cause Tx of an End to End AIS & RDI.
Default: disabled(2)."
::= {atmNteConfVcEntry 12}
atmConfVcLoopbackFailureThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of the LB failures before starting transmission of the
Indication defined by atmConfVcLoopbackFailureInd.
Range: 1..16. Default: 1."
::= {atmNteConfVcEntry 13}
atmConfVcOamDirection OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
downStream (2),
upStream (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The direction of OAM cell insertion.
downStream(2) - The OAM cell will be inserted in downStream.
upStream(3) - The OAM cell will be inserted in upStream."
::= {atmNteConfVcEntry 14}
atmConfVcName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VC Name."
::= {atmNteConfVcEntry 15}
atmConfVcConnected OBJECT-TYPE
SYNTAX INTEGER {
notConnected(1),
mng(2),
bridgePort(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates whether this VC is connected."
::= {atmNteConfVcEntry 16}
--
-- file :v:\doc\rdv\mib\ver485\atm\radima.txt
--
-- RAD-IMA-MIB DEFINITIONS ::= BEGIN
--Title: RAD-IMA MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.
-- IMPORTS
-- OBJECT-TYPE FROM RFC-1212
-- radWan FROM RAD-GEN-MIB;
-- RAD-IMA MIB
--Title: RAD's IMA INTERFACE MIB
--Version: 1.0
--Date: 15.09.98
--By: Ilana Schvetz
--File: radima.mib
-- Last Update 20.01.02 by Ilana Schvetz
radAtmIma OBJECT IDENTIFIER ::= {radAtm 5}
imaPrimaryClk OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
link1(2),
link2(3),
link3(4),
link4(5),
automatic(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source to be transmitted to the user side,
where user module is in 'External' clock source."
::= { radAtmIma 1 }
-- An extension to the Link Table
imaXLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF ImaXLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IMA Link Status and Configuration table.
This table contains additional objects for the link table."
::= { radAtmIma 2 }
imaXLinkEntry OBJECT-TYPE
SYNTAX ImaXLinkEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the IMA Link table."
-- AUGMENTS { imaLinkTable }
INDEX { imaLinkIfIndex }
::= { imaXLinkTable 1 }
ImaXLinkEntry ::=
SEQUENCE {
imaLinkDirection INTEGER,
imaLinkItcLBClkSrc INTEGER
}
imaLinkDirection OBJECT-TYPE
SYNTAX INTEGER {
rx(1),
tx(2),
both(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"the Link direction."
-- DEFAULT { both }
::= { imaXLinkEntry 1 }
imaLinkItcLBClkSrc OBJECT-TYPE
SYNTAX INTEGER {
link1(1),
link2(2),
link3(3),
link4(4),
internal (5),
external (6),
automatic(7),
loopback (8)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clock source for the current Tx-line."
::= { imaXLinkEntry 2 }
-- An extension to the Group Table
imaXGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF ImaXGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IMA group Status and Configuration table.
This table contains additional objects for the Group table."
::= { radAtmIma 3 }
imaXGroupEntry OBJECT-TYPE
SYNTAX ImaXGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the IMA Group table."
-- AUGMENTS { imaGroupTable }
INDEX { imaGroupIndex }
::= { imaXGroupTable 1 }
ImaXGroupEntry ::=
SEQUENCE {
imaGroupVersion INTEGER,
imaGroupCtcTxClkSrc INTEGER,
imaGroupCtcTxClkSrcPort Integer32
}
imaGroupVersion OBJECT-TYPE
SYNTAX INTEGER {
ver10(1),
ver11(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"IMA Version."
::= { imaXGroupEntry 1 }
imaGroupCtcTxClkSrc OBJECT-TYPE
SYNTAX INTEGER {
link1 (1),
link2 (2),
link3 (3),
link4 (4),
internal (5),
external (6),
automatic (7),
loopback (8),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The source of the transmitted, common, Clock Source.
Applicable if imaGroupNeTxClkMode=ctc(1).
Automatic - Dynamic source, taken from the currently reference link.
Internal - taken from the Internal clock on card.
Loopback - Looped back from one of the ports. In this case a specific
port should be selected for imaGroupCtcTxClkSrcPort parameter.
Link N - Clock will be looped from one of the links."
::= { imaXGroupEntry 2 }
imaGroupCtcTxClkSrcPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter is valid only when imaGroupCtcTxClkSrc=loopback.
The value may be any port identifier."
::= { imaXGroupEntry 3 }
-- IMA Traps
--NOTIFICATIONS
atmImaGroupStatusChangeTrap NOTIFICATION-TYPE
OBJECTS { imaGroupFailureStatus }
STATUS current
DESCRIPTION
"This trap indicates IMA Group status change."
::= { radSysAtmEvents 80 }
--
-- file :v:\doc\rdv\mib\ver495\radhdlc.txt
--
-- RAD-HDLC-MIB DEFINITIONS ::= BEGIN
--Title: RAD-HDLC MIB
--
-- Copyright 1998 RAD Data Communications, Ltd.
-- All Rights Reserved.
--Title: RAD's HDLC MIB
--Version: 1.0
--Date: 15.09.98
--By: Ilana Schvetz
--File: radhdlc.mib
--
-- Last Update: 09-Oct-02 By Ilana Schvetz
hdlcMibObjects OBJECT IDENTIFIER ::= {diverseIfWanGen 5}
hdlcTable OBJECT-TYPE
SYNTAX SEQUENCE OF HdlcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDLC configuration table."
::= { hdlcMibObjects 1 }
hdlcEntry OBJECT-TYPE
SYNTAX HdlcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Defines the contents of each line in the RAD HDLC Table."
INDEX { ifIndex }
::= { hdlcTable 1 }
HdlcEntry ::=
SEQUENCE {
hdlcProtocol INTEGER,
hdlcRateResolution INTEGER,
hdlcTxClockSource INTEGER,
hdlcTerminalMode INTEGER,
hdlcLoopbackState INTEGER,
hdlcTxClockPolarity INTEGER,
hdlcFlowControl INTEGER,
hdlcLineRate Integer32,
hdlcRxClockMode INTEGER,
hdlcLOF Gauge32,
hdlcRxClockPolarity INTEGER
}
hdlcProtocol OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
v35(2),
x21(3),
rs530(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The HDLC protocol type
V35 - HDLC encapsulated over V35
X21 - HDLC encapsulated over X21
RS530 - HDLC encapsulated over RS530"
::= { hdlcEntry 1 }
hdlcRateResolution OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
nx56Kbps(2),
nx64Kbps(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { hdlcEntry 2 }
hdlcTxClockSource OBJECT-TYPE
SYNTAX INTEGER {
internal(1),
external(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The baud rate of the internal clock."
::= { hdlcEntry 3 }
hdlcTerminalMode OBJECT-TYPE
SYNTAX INTEGER {
dce(1),
dte(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"."
::= { hdlcEntry 4 }
hdlcLoopbackState OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
internal(2),
external(3),
disable(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"internal - All data coming from the
network port is looped back
external - All data comming from the line is
looped back."
::= { hdlcEntry 5 }
hdlcTxClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
inverse(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"normal - The transmitted data is sampled at the middle of bit time
inverse - The transmitted data is sampled at the end of the bit time
(high data rate/long cable)."
::= { hdlcEntry 6 }
hdlcFlowControl OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Enable/Disable the CTS/RTS flow control signals."
::= { hdlcEntry 7 }
hdlcLineRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The rate values for HDLC are n*56/64Kbps, where 1<=n<=32, 64, 128
and the following values: 1544, 3088, 6176.
The rate values for HSSI is nMbps, where 1<=n<=52."
::= { hdlcEntry 8 }
hdlcRxClockMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
internal (2),
external (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"."
::= { hdlcEntry 9 }
hdlcLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total number of seconds the port is in Loss Of Frame state."
::= { hdlcEntry 10 }
hdlcRxClockPolarity OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
inverse(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"normal - The received data is sampled at the middle of bit time
inverse - The received data is sampled at the end of the bit time
(high data rate/long cable)."
::= { hdlcEntry 11 }
hdlcPerformance OBJECT IDENTIFIER ::= {hdlcMibObjects 2}
hdlcCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF HdlcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDLC Current table."
::= { hdlcPerformance 1 }
hdlcCurrentEntry OBJECT-TYPE
SYNTAX HdlcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the HDLC Current table."
INDEX { hdlcCurrentIfIndex }
::= { hdlcCurrentTable 1 }
HdlcCurrentEntry ::=
SEQUENCE {
hdlcCurrentIfIndex
Integer32,
hdlcCurrentStatus
OCTET STRING,
hdlcCurrentLOF
Gauge32,
hdlcCurrentInFrames
Gauge32,
hdlcCurrentInErrors
Gauge32,
hdlcCurrentOutFrames
Gauge32,
hdlcCurrentAbortedFrames
Gauge32,
hdlcCurrentLengthError
Gauge32
}
hdlcCurrentIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the HDLC interface.
It may be ifIndex."
::= { hdlcCurrentEntry 1 }
hdlcCurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { hdlcCurrentEntry 2 }
hdlcCurrentLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of seconds the
port is in Loss Of Frame state, encountered
by the HDLC interface in the current 15 minute interval."
::= { hdlcCurrentEntry 3 }
hdlcCurrentInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the HDLC interface in the current 15 minute
interval."
::= { hdlcCurrentEntry 4 }
hdlcCurrentInErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored received
frames, encountered by the HDLC interface in the current 15
minute interval."
::= { hdlcCurrentEntry 5 }
hdlcCurrentOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the HDLC interface in the current 15 minute
interval."
::= { hdlcCurrentEntry 6 }
hdlcCurrentAbortedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames, in which
at least seven consecutive '1'-s (Abort sequence) were
encountered by the HDLC interface in the current 15 minute
interval."
::= { hdlcCurrentEntry 7 }
hdlcCurrentLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the HDLC interface in the
current 15 minute interval."
::= { hdlcCurrentEntry 8 }
--Interval Table
hdlcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF HdlcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The HDLC Interval table."
::= { hdlcPerformance 2 }
hdlcIntervalEntry OBJECT-TYPE
SYNTAX HdlcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the HDLC Interval table."
INDEX { hdlcIntervalIfIndex, hdlcIntervalNumber }
::= { hdlcIntervalTable 1 }
HdlcIntervalEntry ::=
SEQUENCE {
hdlcIntervalIfIndex
Integer32,
hdlcIntervalNumber
Integer32,
hdlcIntervalStatus
OCTET STRING,
hdlcIntervalLOF
Gauge32,
hdlcIntervalInFrames
Gauge32,
hdlcIntervalInErrors
Gauge32,
hdlcIntervalOutFrames
Gauge32,
hdlcIntervalAbortedFrames
Gauge32,
hdlcIntervalLengthError
Gauge32
}
hdlcIntervalIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the HDLC interface.
It may be ifIndex."
::= { hdlcIntervalEntry 1 }
hdlcIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { hdlcIntervalEntry 2 }
hdlcIntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { hdlcIntervalEntry 3 }
hdlcIntervalLOF OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of seconds the
port is in Loss Of Frame state, encountered by an HDLC
interface in one of the previous 96, individual 15 minute,
intervals."
::= { hdlcIntervalEntry 4 }
hdlcIntervalInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the HDLC interface in one of the previous 96,
individual 15 minute, intervals."
::= { hdlcIntervalEntry 5 }
hdlcIntervalInErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored received
frames, encountered by the HDLC interface in one of the
previous 96, individual 15 minute, intervals."
::= { hdlcIntervalEntry 6 }
hdlcIntervalOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
frames, encountered by the HDLC interface in one of
the previous 96, individual 15 minute, intervals."
::= { hdlcIntervalEntry 7 }
hdlcIntervalAbortedFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames, in which
at least seven consecutive '1'-s (Abort sequence) were
encountered by the HDLC interface in one of the previous 96,
individual 15 minute, intervals."
::= { hdlcIntervalEntry 8 }
hdlcIntervalLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the HDLC interface in
one of the previous 96, individual 15 minute, intervals."
::= { hdlcIntervalEntry 9 }
--
-- file :v:\doc\rdv\mib\ver525\atm\ace101.txt
--
--
-- file :v:\doc\rdv\mib\ver525\ATM\ace101.txt
--RAD-ARC-MIB
-- DEFINITIONS ::= BEGIN
--Title: RAD-ACE MIB
--
-- IMPORTS
-- Gauge32, IpAddress FROM RFC1155-SMI
-- ifIndex FROM IF-MIB
-- OBJECT-TYPE FROM RFC-1212
-- TRAP-TYPE FROM RFC-1215
-- radAtm, agnLed, agnIndication FROM RAD-GEN-MIB
-- RowStatus FROM SNMPv2-TC
-- atmVplVpi, atmVclVpi, atmVclVci FROM ATM-MIB;
-- RAD-ACE MIB
--Title: RAD's ARC ATM PRODUCT MIB
--Version: 1.0
--Date: 24.9.96
--By: Yair Arian
--File: arc.mib
--
--Last update: 19-Dec-2005 by Ilana Schvetz
atmGen OBJECT IDENTIFIER ::= {radAtm 2}
atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1}
atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1}
-- aal5VccXTable ::= { atmIfPerformance 4 } in aal5.txt
atmIfDataTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM interface Data table."
::= { atmIfPerformance 1 }
atmIfDataEntry OBJECT-TYPE
SYNTAX AtmIfDataEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM interface Data table."
INDEX { ifIndex }
::= { atmIfDataTable 1 }
AtmIfDataEntry ::=
SEQUENCE {
atmIfTimeElapsed
Integer32,
atmIfValidIntervals
Integer32
}
atmIfTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (0..899)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since
the beginning of the near end current error-
measurement period."
::= { atmIfDataEntry 1 }
atmIfValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous near end intervals for
which valid data was collected. The value will be
96 unless the interface was brought online within
the last 24 hours, in which case the value will be
the number of complete 15 minute near end
intervals since the interface has been online."
::= { atmIfDataEntry 2 }
-- the ATM interface Current
-- The ATM interface current table contains various statistics being
-- collected for the current 15 minute interval.
atmIfCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM interface Current table."
::= { atmIfPerformance 2 }
atmIfCurrentEntry OBJECT-TYPE
SYNTAX AtmIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM interface Current table."
INDEX { ifIndex }
::= { atmIfCurrentTable 1 }
AtmIfCurrentEntry ::=
SEQUENCE {
atmIfCurrentTxCells
Gauge32,
atmIfCurrentRxCells
Gauge32,
atmIfCurrentCorrectedHecs
Gauge32,
atmIfCurrentUncorrectedHecs
Gauge32,
atmIfCurrentHecErrorSeconds
Gauge32
}
atmIfCurrentTxCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells, encountered by an ATM interface in
the current 15 minute interval."
::= { atmIfCurrentEntry 1 }
atmIfCurrentRxCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by an ATM
interface in the current 15 minute interval."
::= { atmIfCurrentEntry 2 }
atmIfCurrentCorrectedHecs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells with
corrected HEC errors, encountered by an
ATM interface in the current 15 minute
interval."
::= { atmIfCurrentEntry 3 }
atmIfCurrentUncorrectedHecs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells with
uncorrected HEC errors, encountered by an ATM
interface in the current 15 minute interval."
::= { atmIfCurrentEntry 4 }
atmIfCurrentHecErrorSeconds OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of seconds with
HEC errors, encountered by an ATM interface in
the current 15 minute interval."
::= { atmIfCurrentEntry 5 }
-- the ATM interface Interval
-- The ATM interface Interval Table contains various statistics
-- collected by each ATM Interface over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmIfIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM interface Interval table."
::= { atmIfPerformance 3 }
atmIfIntervalEntry OBJECT-TYPE
SYNTAX AtmIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM interface Interval table."
INDEX { ifIndex, atmIfIntervalNumber }
::= { atmIfIntervalTable 1 }
AtmIfIntervalEntry ::=
SEQUENCE {
atmIfIntervalNumber
Integer32,
atmIfIntervalTxCells
Gauge32,
atmIfIntervalRxCells
Gauge32,
atmIfIntervalCorrectedHecs
Gauge32,
atmIfIntervalUncorrectedHecs
Gauge32,
atmIfIntervalHecErrorSeconds
Gauge32
}
atmIfIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmIfIntervalEntry 1 }
atmIfIntervalTxCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells , encountered by an ATM interface in
one of the previous 96, individual 15 minute,
intervals."
::= { atmIfIntervalEntry 2 }
atmIfIntervalRxCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by an ATM
interface in one of the previous 96, individual 15
minute, intervals."
::= { atmIfIntervalEntry 3 }
atmIfIntervalCorrectedHecs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells with
corrected HEC errors, encountered by an
ATM interface in one of the previous 96,
individual 15 minute, intervals."
::= { atmIfIntervalEntry 4 }
atmIfIntervalUncorrectedHecs OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells with
uncorrected HEC errors, encountered by an ATM
interface in one of the previous 96, individual 15
minute, intervals."
::= { atmIfIntervalEntry 5 }
atmIfIntervalHecErrorSeconds OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of seconds with
HEC errors, encountered by an ATM interface in one of
the previous 96, individual 15 minute, intervals."
::= { atmIfIntervalEntry 6 }
atmPvcPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 2}
atmVpPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 1}
-- the ATM VP Current
-- The ATM VP current table contains various statistics being
-- collected for the current 15 minute interval.
atmVpCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP Current table."
::= { atmVpPerformance 1 }
atmVpCurrentEntry OBJECT-TYPE
SYNTAX AtmVpCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP Current table."
INDEX { ifIndex, atmVpCurrentVpi }
::= { atmVpCurrentTable 1 }
AtmVpCurrentEntry ::=
SEQUENCE {
atmVpCurrentVpi
Integer32,
atmVpCurrentRxCellsClp01
Gauge32,
atmVpCurrentRxCellsClp0
Gauge32,
atmVpCurrentGcra0Violations
Gauge32,
atmVpCurrentGcra1Violations
Gauge32,
atmVpCurrentRxAIS
Gauge32,
atmVpCurrentTxAIS
Gauge32,
atmVpCurrentRxRDI
Gauge32,
atmVpCurrentTxRDI
Gauge32,
atmVpCurrentContinuityLoss
Gauge32,
atmVpCurrentUAS
Gauge32,
atmVpCurrentSES
Gauge32,
atmVpCurrentCDC
Gauge32,
atmVpCurrentTotalDiscards
Gauge32,
atmVpCurrentClp0Discards
Gauge32,
atmVpCurrentTotalCellOuts
Gauge32,
atmVpCurrentClp0CellOuts
Gauge32,
atmVpCurrentTaggedOuts
Gauge32,
atmVpCurrentPCR
Gauge32,
atmVpCurrentSCR
Gauge32,
atmVpCurrentMCR
Gauge32,
atmVpCurrentShaperTotalDiscards
Gauge32,
atmVpCurrentShaperClp0Discards
Gauge32,
atmVpCurrentShaperClp1Discards
Gauge32
}
atmVpCurrentVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VPL."
::= { atmVpCurrentEntry 1 }
atmVpCurrentRxCellsClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells, encountered by the VPL of this ATM interface in
the current 15 minute interval."
::= { atmVpCurrentEntry 2 }
atmVpCurrentRxCellsClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 3 }
atmVpCurrentGcra0Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells
violating GCRA0, encountered by the VPL of this
ATM interface in the current 15 minute
interval."
::= { atmVpCurrentEntry 4 }
atmVpCurrentGcra1Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells
violating GCRA1, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 5 }
atmVpCurrentRxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
AIS cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 6 }
atmVpCurrentTxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
AIS cells, encountered by the VPL of this ATM
interface in the current 15 minute interval. Not Supported
in the first phase."
::= { atmVpCurrentEntry 7 }
atmVpCurrentRxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
RDI cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 8 }
atmVpCurrentTxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
RDI cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 9 }
atmVpCurrentContinuityLoss OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of loss of
continuity cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 10 }
atmVpCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 11 }
atmVpCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severerly Errored
Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpCurrentEntry 12 }
atmVpCurrentCDC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of cells dropped in the current 15 minute interval
of the VP connection."
::= { atmVpCurrentEntry 13 }
atmVpCurrentTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1."
::= { atmVpCurrentEntry 14 }
atmVpCurrentClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with
CLP=0 and discarded by the traffic policing
entity."
::= { atmVpCurrentEntry 15 }
atmVpCurrentTotalCellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
by this VPL. This includes both CLP=0 and CLP=1
cells."
::= { atmVpCurrentEntry 16 }
atmVpCurrentClp0CellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
with CLP=0 by this VPL."
::= { atmVpCurrentEntry 17 }
atmVpCurrentTaggedOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VPL."
::= { atmVpCurrentEntry 18 }
atmVpCurrentPCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum traffic rate encountered in the
last interval of the VP connection (monitored once a second)."
::= { atmVpCurrentEntry 19 }
atmVpCurrentSCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average traffic rate during the last interval of the VP
connection."
::= { atmVpCurrentEntry 20 }
atmVpCurrentMCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MCR - The minimum traffic rate encountered in the last
interval of the VP connection (monitored once a second)."
::= { atmVpCurrentEntry 21 }
atmVpCurrentShaperTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells (CLP0 and CLP1) discarded
due to congestion by the traffic shaper."
::= { atmVpCurrentEntry 22 }
atmVpCurrentShaperClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP0 cells discarded
due to congestion by the traffic shaper."
::= { atmVpCurrentEntry 23 }
atmVpCurrentShaperClp1Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP1 cells discarded
due to congestion by the traffic shaper."
::= { atmVpCurrentEntry 24 }
-- The ATM VP current table for Performance Management
-- which contains various statistics being
-- collected for the current 15 minute interval.
atmVpPMCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP Current table for Performance Management."
::= { atmVpPerformance 2 }
atmVpPMCurrentEntry OBJECT-TYPE
SYNTAX AtmVpPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP Current table for Performance
Management."
INDEX { ifIndex, atmVpPMCurrentVpi, atmVpPMCurrentDir }
::= { atmVpPMCurrentTable 1 }
AtmVpPMCurrentEntry ::=
SEQUENCE {
atmVpPMCurrentDir
INTEGER,
atmVpPMCurrentVpi
Integer32,
atmVpPMCurrentTxClp01
Gauge32,
atmVpPMCurrentTxClp0
Gauge32,
atmVpPMCurrentRxClp01
Gauge32,
atmVpPMCurrentRxClp0
Gauge32,
atmVpPMCurrentErroredCells
Gauge32,
atmVpPMCurrentLostCells
Gauge32,
atmVpPMCurrentMisinsertedCells
Gauge32,
atmVpPMCurrentECB
Gauge32,
atmVpPMCurrentSECB
Gauge32,
atmVpPMCurrentES
Gauge32,
atmVpPMCurrentSES
Gauge32,
atmVpPMCurrentUAS
Gauge32,
atmVpPMCurrentIntervalQuality
INTEGER,
atmVpPMCurrentLastDayQuality
INTEGER
}
atmVpPMCurrentVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VPL."
::= { atmVpPMCurrentEntry 1 }
atmVpPMCurrentDir OBJECT-TYPE
SYNTAX INTEGER {forward(2), backward(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of performance management."
::= { atmVpPMCurrentEntry 2 }
atmVpPMCurrentTxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0+1 cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 3 }
atmVpPMCurrentTxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0 cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 4 }
atmVpPMCurrentRxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0+1 cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 5 }
atmVpPMCurrentRxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0 cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 6 }
atmVpPMCurrentErroredCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of errored
cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 7 }
atmVpPMCurrentLostCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of lost
cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 8 }
atmVpPMCurrentMisinsertedCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of misinserted
cells, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 9 }
atmVpPMCurrentECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of ECB,
encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 10 }
atmVpPMCurrentSECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SECB,
encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 11 }
atmVpPMCurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Errored Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 12 }
atmVpPMCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 13 }
atmVpPMCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by the VPL of this ATM
interface in the current 15 minute interval."
::= { atmVpPMCurrentEntry 14 }
atmVpPMCurrentIntervalQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), unacceptable(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per interval is superior to
the atmNteUPLTCR value, the quality of service of
the interval is declared as unacceptable."
DEFVAL { normal }
::= { atmVpPMCurrentEntry 15 }
atmVpPMCurrentLastDayQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), degraded(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per 24 hours is superior to
the atmNteDPLTCR value, the quality of service of
the day is declared as degraded."
DEFVAL { normal }
::= { atmVpPMCurrentEntry 16 }
-- the ATM VP Interval
-- The ATM VP Interval Table contains various statistics
-- collected by each ATM Interface/VP over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmVpIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Vp Interval table."
::= { atmVpPerformance 3 }
atmVpIntervalEntry OBJECT-TYPE
SYNTAX AtmVpIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vp Interval table."
INDEX { ifIndex, atmVpIntervalVpi,
atmVpIntervalNumber }
::= { atmVpIntervalTable 1 }
AtmVpIntervalEntry ::=
SEQUENCE {
atmVpIntervalVpi
Integer32,
atmVpIntervalNumber
Integer32,
atmVpIntervalRxCellsClp01
Gauge32,
atmVpIntervalRxCellsClp0
Gauge32,
atmVpIntervalGcra0Violations
Gauge32,
atmVpIntervalGcra1Violations
Gauge32,
atmVpIntervalRxAIS
Gauge32,
atmVpIntervalTxAIS
Gauge32,
atmVpIntervalRxRDI
Gauge32,
atmVpIntervalTxRDI
Gauge32,
atmVpIntervalContinuityLoss
Gauge32,
atmVpIntervalUAS
Gauge32,
atmVpIntervalSES
Gauge32,
atmVpIntervalCDC
Gauge32,
atmVpIntervalTotalDiscards
Gauge32,
atmVpIntervalClp0Discards
Gauge32,
atmVpIntervalTotalCellOuts
Gauge32,
atmVpIntervalClp0CellOuts
Gauge32,
atmVpIntervalTaggedOuts
Gauge32,
atmVpIntervalPCR
Gauge32,
atmVpIntervalSCR
Gauge32,
atmVpIntervalMCR
Gauge32,
atmVpIntervalShaperTotalDiscards
Gauge32,
atmVpIntervalShaperClp0Discards
Gauge32,
atmVpIntervalShaperClp1Discards
Gauge32
}
atmVpIntervalVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VPL."
::= { atmVpIntervalEntry 1 }
atmVpIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmVpIntervalEntry 2 }
atmVpIntervalRxCellsClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells , encountered by an ATM interface/VP in
one of the previous 96, individual 15 minute,
intervals."
::= { atmVpIntervalEntry 3 }
atmVpIntervalRxCellsClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 4 }
atmVpIntervalGcra0Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
cells violating GCRA0, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 5 }
atmVpIntervalGcra1Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
cells violating GCRA1, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 6 }
atmVpIntervalRxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
AIS cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 7 }
atmVpIntervalTxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
AIS cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals. Not supported in the first phase."
::= { atmVpIntervalEntry 8 }
atmVpIntervalRxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
RDI cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 9 }
atmVpIntervalTxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
RDI cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 10 }
atmVpIntervalContinuityLoss OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Continuity
Loss cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 11 }
atmVpIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 12 }
atmVpIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severerly Errored
Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpIntervalEntry 13 }
atmVpIntervalCDC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of cells dropped in the 15 minute interval
of the VP connection."
::= { atmVpIntervalEntry 14 }
atmVpIntervalTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1."
::= { atmVpIntervalEntry 15 }
atmVpIntervalClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with
CLP=0 an discarded by the traffic policing
entity."
::= { atmVpIntervalEntry 16 }
atmVpIntervalTotalCellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
by this VPL. This includes both CLP=0 and CLP=1
cells."
::= { atmVpIntervalEntry 17 }
atmVpIntervalClp0CellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
with CLP=0 by this VPL."
::= { atmVpIntervalEntry 18 }
atmVpIntervalTaggedOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VPL."
::= { atmVpIntervalEntry 19 }
atmVpIntervalPCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum traffic rate encountered in the last
interval of the VP connection (monitored once a second)
encountered by an ATM interface/VP in one of the previous
96, individual 15 minute, intervals."
::= { atmVpIntervalEntry 20 }
atmVpIntervalSCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average traffic rate during the last interval of the
VP connection , encountered by an ATM interface/VP in one
of the previous 96, individual 15 minute, intervals."
::= { atmVpIntervalEntry 21 }
atmVpIntervalMCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MCR - The minimum traffic rate encountered in the last
interval of the VP connection (monitored once a second)
encountered by an ATM interface/VP in one of the previous
96, individual 15 minute, intervals."
::= { atmVpIntervalEntry 22 }
atmVpIntervalShaperTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells (CLP0 and CLP1) discarded
due to congestion by the traffic shaper."
::= { atmVpIntervalEntry 23 }
atmVpIntervalShaperClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP0 cells discarded
due to congestion by the traffic shaper."
::= { atmVpIntervalEntry 24 }
atmVpIntervalShaperClp1Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP1 cells discarded
due to congestion by the traffic shaper."
::= { atmVpIntervalEntry 25 }
-- The ATM VP Interval Table for Performance Management
-- contains various statistics
-- collected by each ATM Interface/VP over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmVpPMIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Vp Interval table for Performance Management."
::= { atmVpPerformance 4 }
atmVpPMIntervalEntry OBJECT-TYPE
SYNTAX AtmVpPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vp Interval table for Performance
Management."
INDEX { ifIndex, atmVpPMIntervalVpi, atmVpPMIntervalDir, atmVpPMIntervalNumber }
::= { atmVpPMIntervalTable 1 }
AtmVpPMIntervalEntry ::=
SEQUENCE {
atmVpPMIntervalVpi
Integer32,
atmVpPMIntervalDir
INTEGER,
atmVpPMIntervalNumber
Integer32,
atmVpPMIntervalTxClp01
Gauge32,
atmVpPMIntervalTxClp0
Gauge32,
atmVpPMIntervalRxClp01
Gauge32,
atmVpPMIntervalRxClp0
Gauge32,
atmVpPMIntervalErroredCells
Gauge32,
atmVpPMIntervalLostCells
Gauge32,
atmVpPMIntervalMisinsertedCells
Gauge32,
atmVpPMIntervalECB
Gauge32,
atmVpPMIntervalSECB
Gauge32,
atmVpPMIntervalES
Gauge32,
atmVpPMIntervalSES
Gauge32,
atmVpPMIntervalUAS
Gauge32,
atmVpPMIntervalQuality
INTEGER,
atmVpPMIntervalLastDayQuality
INTEGER
}
atmVpPMIntervalVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VPL."
::= { atmVpPMIntervalEntry 1 }
atmVpPMIntervalDir OBJECT-TYPE
SYNTAX INTEGER {forward(2),
backward(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of performance management."
::= { atmVpPMIntervalEntry 2 }
atmVpPMIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmVpPMIntervalEntry 3 }
atmVpPMIntervalTxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0+1 cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 4 }
atmVpPMIntervalTxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0 cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 5 }
atmVpPMIntervalRxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0+1 cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 6 }
atmVpPMIntervalRxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0 cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 7 }
atmVpPMIntervalErroredCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 8 }
atmVpPMIntervalLostCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Lost
cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 9 }
atmVpPMIntervalMisinsertedCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Misinserted
cells, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 10 }
atmVpPMIntervalECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of ECBs
encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 11 }
atmVpPMIntervalSECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SECBs
encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 12 }
atmVpPMIntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 13 }
atmVpPMIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 14 }
atmVpPMIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by an ATM
interface/VP in one of the previous 96, individual 15
minute, intervals."
::= { atmVpPMIntervalEntry 15 }
atmVpPMIntervalQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), unacceptable(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per interval is superior to
the atmNteUPLTCR value, the quality of service of
the interval is declared as unacceptable."
DEFVAL { normal }
::= { atmVpPMIntervalEntry 16}
atmVpPMIntervalLastDayQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), degraded(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per 24 hours is superior to
the atmNteDPLTCR value, the quality of service of
the day is declared as degraded."
DEFVAL { normal }
::= { atmVpPMIntervalEntry 17}
-- VP QoS Table
atmVpQoSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The VP QoS table."
::= { atmVpPerformance 5 }
atmVpQoSEntry OBJECT-TYPE
SYNTAX AtmVpQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { ifIndex, atmVplVpi, atmVpQoSPeriodRef }
::= { atmVpQoSTable 1 }
AtmVpQoSEntry ::=
SEQUENCE {
atmVpQoSPeriodRef INTEGER,
atmVpQoSElapsedTime Integer32,
atmVpQoSUAS Gauge32
}
atmVpQoSPeriodRef OBJECT-TYPE
SYNTAX INTEGER {
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
2 objects refer to.
currentPeriod - the period since last systemResetAllStatsCmd received or
since Start-up (if no systemResetAllStatsCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
- If only one command occurred since Start-up: the period between
Start-up and last command.
- If no command occurred since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { atmVpQoSEntry 1 }
atmVpQoSElapsedTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed Time in seconds.
- for atmVpQoSPeriodRef = currentPeriod:
The period since last systemResetAllStatsCmd received or since Start-up
(if no systemResetAllStatsCmd was received since Start-up) until now.
- for atmVpQoSPeriodRef = lastPeriod:
The value of atmVpQoSElapsedTime when last systemResetAllStatsCmd
was received."
::= { atmVpQoSEntry 2 }
atmVpQoSUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Unavailable Seconds for the reference period (atmVpQoSPeriodRef)."
::= { atmVpQoSEntry 3 }
-- VP PM QoS Table
atmVpPMQoSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpPMQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The PM VP QoS table."
::= { atmVpPerformance 6 }
atmVpPMQoSEntry OBJECT-TYPE
SYNTAX AtmVpPMQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { ifIndex, atmVplVpi, atmVpPMQoSDirection ,atmVpPMQoSPeriodRef }
::= { atmVpPMQoSTable 1 }
AtmVpPMQoSEntry ::=
SEQUENCE {
atmVpPMQoSDirection INTEGER,
atmVpPMQoSPeriodRef INTEGER,
atmVpPMQoSCLR Gauge32,
atmVpPMQoSCER Gauge32,
atmVpPMQoSCMR Gauge32
}
atmVpPMQoSDirection OBJECT-TYPE
SYNTAX INTEGER
{
forward (2),
backward (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of performance management."
::= { atmVpPMQoSEntry 1 }
atmVpPMQoSPeriodRef OBJECT-TYPE
SYNTAX INTEGER
{
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
5 objects refer to.
currentPeriod - the period since last systemResetAllStatsCmd received or
since Start-up (if no systemResetAllStatsCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
- If only one command occurred since Start-up: the period between
Start-up and last command.
- If no command occurred since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { atmVpPMQoSEntry 2 }
atmVpPMQoSCLR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Loss Ratio counter for the reference period (atmVpPMQoSPeriodRef)-
defined in accordance with I.356 , in %.
The value will be multipuled by 100."
::= { atmVpPMQoSEntry 3 }
atmVpPMQoSCER OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Error Ratio counter for the reference period (atmVpPMQoSPeriodRef)
defined in accordance with I.356 , in %.
The value will be multipuled by 100."
::= { atmVpPMQoSEntry 4 }
atmVpPMQoSCMR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Misinsertion Ratio counter for the reference period (atmVpPMQoSPeriodRef)
defined in accordance with I.356 , cells/sec ."
::= { atmVpPMQoSEntry 5 }
--VP Shaper Statistics Table
atmVpShaperStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpShaperStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP shaper statistics table."
::= { atmVpPerformance 7 }
atmVpShaperStatEntry OBJECT-TYPE
SYNTAX AtmVpShaperStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP shaper statistics table."
INDEX { ifIndex, atmVplVpi }
::= { atmVpShaperStatTable 1 }
AtmVpShaperStatEntry ::=
SEQUENCE {
atmVpShaperDiscarded Counter32,
atmVpShaperOccupation Integer32,
atmVpShaperMaxOccupation Integer32,
atmVpShaperLevel INTEGER,
atmVpShaperEpdDropped Counter32,
atmVpShaperTotalEpdDropped Counter32
}
atmVpShaperDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that were discarded in the shaper on that VPC due
to buffer overflow.
This counter counts till it reaches its MAX value (20 bits) and then
rolls over."
::= { atmVpShaperStatEntry 1 }
atmVpShaperOccupation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that are currently stored in the buffer.
This parameter is limited to 20 bits."
::= { atmVpShaperStatEntry 2}
atmVpShaperMaxOccupation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum number of Cells that were stored in the buffer,
since this VP was activated. This parameter is limited to 20 bits."
::= { atmVpShaperStatEntry 3}
atmVpShaperLevel OBJECT-TYPE
SYNTAX INTEGER {
empty (1),
full (2),
below (3),
above (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The occupation of the buffer according to a predefined threshold.
empty - buffer is Empty
full - buffer is Full
below - buffer is Below the threshold
above - buffer is Above the threshold. This is also the trigger to
start EPD\PPD mechanism, if set for the VPC."
::= { atmVpShaperStatEntry 4}
atmVpShaperEpdDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that were dropped in the shaper on that VPC
due to EPD\PPD mechanism in the last second.
This parameter is limited to 24 bits.
Applicable for a EPD/PPD VP only."
::= { atmVpShaperStatEntry 5}
atmVpShaperTotalEpdDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Total number of Cells that were dropped in the shaper on that
VPC due to EPD\PPD mechanism in the last 15 minutes. This counter
automatically reset itself every 15 minutes.
Applicable for a EPD/PPD VP only."
::= { atmVpShaperStatEntry 6}
atmVcPerformance OBJECT IDENTIFIER ::= {atmPvcPerformance 2}
-- the ATM VC Current
-- The ATM VC current table contains various statistics being
-- collected for the current 15 minute interval.
atmVcCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC Current table."
::= { atmVcPerformance 1 }
atmVcCurrentEntry OBJECT-TYPE
SYNTAX AtmVcCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC Current table."
INDEX { ifIndex, atmVcCurrentVpi, atmVcCurrentVci }
::= { atmVcCurrentTable 1 }
AtmVcCurrentEntry ::=
SEQUENCE {
atmVcCurrentVpi
Integer32,
atmVcCurrentVci
Integer32,
atmVcCurrentRxCellsClp01
Gauge32,
atmVcCurrentRxCellsClp0
Gauge32,
atmVcCurrentGcra0Violations
Gauge32,
atmVcCurrentGcra1Violations
Gauge32,
atmVcCurrentRxAIS
Gauge32,
atmVcCurrentTxAIS
Gauge32,
atmVcCurrentRxRDI
Gauge32,
atmVcCurrentTxRDI
Gauge32,
atmVcCurrentContinuityLoss
Gauge32,
atmVcCurrentUAS
Gauge32,
atmVcCurrentSES
Gauge32,
atmVcCurrentCDC
Gauge32,
atmVcCurrentTotalDiscards
Gauge32,
atmVcCurrentClp0Discards
Gauge32,
atmVcCurrentTotalCellOuts
Gauge32,
atmVcCurrentClp0CellOuts
Gauge32,
atmVcCurrentTaggedOuts
Gauge32,
atmVcCurrentPCR
Gauge32,
atmVcCurrentSCR
Gauge32,
atmVcCurrentMCR
Gauge32,
atmVcCurrentShaperTotalDiscards
Gauge32,
atmVcCurrentShaperClp0Discards
Gauge32,
atmVcCurrentShaperClp1Discards
Gauge32
}
atmVcCurrentVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VCL."
::= { atmVcCurrentEntry 1 }
atmVcCurrentVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VCL."
::= { atmVcCurrentEntry 2 }
atmVcCurrentRxCellsClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells, encountered by the VCL of this ATM interface in
the current 15 minute interval."
::= { atmVcCurrentEntry 3 }
atmVcCurrentRxCellsClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 4 }
atmVcCurrentGcra0Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells
violating GCRA0, encountered by the VCL of this
ATM interface in the current 15 minute
interval."
::= { atmVcCurrentEntry 5 }
atmVcCurrentGcra1Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of cells
violating GCRA1, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 6 }
atmVcCurrentRxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
AIS cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 7 }
atmVcCurrentTxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
AIS cells, encountered by the VCL of this ATM
interface in the current 15 minute interval. Not Supported
in the first phase."
::= { atmVcCurrentEntry 8 }
atmVcCurrentRxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
RDI cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 9 }
atmVcCurrentTxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
RDI cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 10 }
atmVcCurrentContinuityLoss OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of loss of
continuity cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 11 }
atmVcCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 12 }
atmVcCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severerly Errored
Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcCurrentEntry 13 }
atmVcCurrentCDC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of cells dropped in the current 15 minute interval
of the VC connection."
::= { atmVcCurrentEntry 14 }
atmVcCurrentTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1."
::= { atmVcCurrentEntry 15 }
atmVcCurrentClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with
CLP=0 an discarded by the traffic policing
entity."
::= { atmVcCurrentEntry 16 }
atmVcCurrentTotalCellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
by this VPL. This includes both CLP=0 and CLP=1
cells."
::= { atmVcCurrentEntry 17 }
atmVcCurrentClp0CellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
with CLP=0 by this VPL."
::= { atmVcCurrentEntry 18 }
atmVcCurrentTaggedOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VPL."
::= { atmVcCurrentEntry 19 }
atmVcCurrentPCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum traffic rate encountered in the last
interval of the VC connection (monitored once a second)."
::= { atmVcCurrentEntry 20 }
atmVcCurrentSCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average traffic rate during the last interval
of the VC connection."
::= { atmVcCurrentEntry 21 }
atmVcCurrentMCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MCR - The minimum traffic rate encountered in the last
interval of the VC connection (monitored once a second)."
::= { atmVcCurrentEntry 22 }
atmVcCurrentShaperTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells (CLP0 and CLP1) discarded
due to congestion by the traffic shaper."
::= { atmVcCurrentEntry 23 }
atmVcCurrentShaperClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP0 cells discarded
due to congestion by the traffic shaper."
::= { atmVcCurrentEntry 24 }
atmVcCurrentShaperClp1Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP1 cells discarded
due to congestion by the traffic shaper."
::= { atmVcCurrentEntry 25 }
-- The ATM VC current table for Performance Management
-- which contains various statistics being
-- collected for the current 15 minute interval.
atmVcPMCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC Current table for Performance Management."
::= { atmVcPerformance 2 }
atmVcPMCurrentEntry OBJECT-TYPE
SYNTAX AtmVcPMCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC Current table for Performance
Management."
INDEX { ifIndex, atmVcPMCurrentVpi,
atmVcPMCurrentVci, atmVcPMCurrentDir }
::= { atmVcPMCurrentTable 1 }
AtmVcPMCurrentEntry ::=
SEQUENCE {
atmVcPMCurrentVpi
Integer32,
atmVcPMCurrentVci
Integer32,
atmVcPMCurrentDir
Integer32,
atmVcPMCurrentTxClp01
Gauge32,
atmVcPMCurrentTxClp0
Gauge32,
atmVcPMCurrentRxClp01
Gauge32,
atmVcPMCurrentRxClp0
Gauge32,
atmVcPMCurrentErroredCells
Gauge32,
atmVcPMCurrentLostCells
Gauge32,
atmVcPMCurrentMisinsertedCells
Gauge32,
atmVcPMCurrentECB
Gauge32,
atmVcPMCurrentSECB
Gauge32,
atmVcPMCurrentES
Gauge32,
atmVcPMCurrentSES
Gauge32,
atmVcPMCurrentUAS
Gauge32,
atmVcPMCurrentIntervalQuality
INTEGER,
atmVcPMCurrentLastDayQuality
INTEGER
}
atmVcPMCurrentVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VCL."
::= { atmVcPMCurrentEntry 1 }
atmVcPMCurrentVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VCL."
::= { atmVcPMCurrentEntry 2 }
atmVcPMCurrentDir OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of Performance Management."
::= { atmVcPMCurrentEntry 3 }
atmVcPMCurrentTxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0+1 cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 4 }
atmVcPMCurrentTxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0 cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 5 }
atmVcPMCurrentRxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0+1 cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 6 }
atmVcPMCurrentRxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0 cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 7 }
atmVcPMCurrentErroredCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of errored
cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 8 }
atmVcPMCurrentLostCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of lost
cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 9 }
atmVcPMCurrentMisinsertedCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of misinserted
cells, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 10 }
atmVcPMCurrentECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of ECBs
encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 11 }
atmVcPMCurrentSECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SECBs
encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 12 }
atmVcPMCurrentES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Errored Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 13 }
atmVcPMCurrentSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 14 }
atmVcPMCurrentUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by the VCL of this ATM
interface in the current 15 minute interval."
::= { atmVcPMCurrentEntry 15 }
atmVcPMCurrentIntervalQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), unacceptable(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per interval is superior to
the atmNteUPLTCR value, the quality of service of
the interval is declared as unacceptable."
DEFVAL { normal }
::= { atmVcPMCurrentEntry 16 }
atmVcPMCurrentLastDayQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), degraded(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per 24 hours is superior to
the atmNteDPLTCR value, the quality of service of
the day is declared as degraded."
DEFVAL { normal }
::= { atmVcPMCurrentEntry 17 }
-- the ATM VC Interval
-- The ATM VC Interval Table contains various statistics
-- collected by each ATM Interface/VC over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmVcIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Vc Interval table."
::= { atmVcPerformance 3 }
atmVcIntervalEntry OBJECT-TYPE
SYNTAX AtmVcIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vc Interval table."
INDEX { ifIndex, atmVcIntervalVpi,
atmVcIntervalVci, atmVcIntervalNumber }
::= { atmVcIntervalTable 1 }
AtmVcIntervalEntry ::=
SEQUENCE {
atmVcIntervalVpi
Integer32,
atmVcIntervalVci
Integer32,
atmVcIntervalNumber
Integer32,
atmVcIntervalRxCellsClp01
Gauge32,
atmVcIntervalRxCellsClp0
Gauge32,
atmVcIntervalGcra0Violations
Gauge32,
atmVcIntervalGcra1Violations
Gauge32,
atmVcIntervalRxAIS
Gauge32,
atmVcIntervalTxAIS
Gauge32,
atmVcIntervalRxRDI
Gauge32,
atmVcIntervalTxRDI
Gauge32,
atmVcIntervalContinuityLoss
Gauge32,
atmVcIntervalUAS
Gauge32,
atmVcIntervalSES
Gauge32,
atmVcIntervalCDC
Gauge32,
atmVcIntervalTotalDiscards
Gauge32,
atmVcIntervalClp0Discards
Gauge32,
atmVcIntervalTotalCellOuts
Gauge32,
atmVcIntervalClp0CellOuts
Gauge32,
atmVcIntervalTaggedOuts
Gauge32,
atmVcIntervalPCR
Gauge32,
atmVcIntervalSCR
Gauge32,
atmVcIntervalMCR
Gauge32,
atmVcIntervalShaperTotalDiscards
Gauge32,
atmVcIntervalShaperClp0Discards
Gauge32,
atmVcIntervalShaperClp1Discards
Gauge32
}
atmVcIntervalVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VCL."
::= { atmVcIntervalEntry 1 }
atmVcIntervalVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VCL."
::= { atmVcIntervalEntry 2 }
atmVcIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmVcIntervalEntry 3 }
atmVcIntervalRxCellsClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
cells , encountered by an ATM interface/VC in
one of the previous 96, individual 15 minute,
intervals."
::= { atmVcIntervalEntry 4 }
atmVcIntervalRxCellsClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 5 }
atmVcIntervalGcra0Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
cells violating GCRA0, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 6 }
atmVcIntervalGcra1Violations OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
cells violating GCRA1, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 7 }
atmVcIntervalRxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
AIS cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 8 }
atmVcIntervalTxAIS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
AIS cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals. Not supported in the first phase."
::= { atmVcIntervalEntry 9 }
atmVcIntervalRxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
RDI cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 10 }
atmVcIntervalTxRDI OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
RDI cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 11 }
atmVcIntervalContinuityLoss OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Continuity
Loss cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 12 }
atmVcIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 13 }
atmVcIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severerly Errored
Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcIntervalEntry 14 }
atmVcIntervalCDC OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Amount of cells dropped in the 15 minute interval
of the VC connection."
::= { atmVcIntervalEntry 15 }
atmVcIntervalTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells discarded by
the traffic policing entity. This includes cells
originally received with CLP=0 and CLP=1."
::= { atmVcIntervalEntry 16 }
atmVcIntervalClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells received with
CLP=0 an discarded by the traffic policing
entity."
::= { atmVcIntervalEntry 17 }
atmVcIntervalTotalCellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
by this VPL. This includes both CLP=0 and CLP=1
cells."
::= { atmVcIntervalEntry 18 }
atmVcIntervalClp0CellOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells transmitted
with CLP=0 by this VPL."
::= { atmVcIntervalEntry 19 }
atmVcIntervalTaggedOuts OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of valid ATM cells tagged by the
traffic policing entity from CLP=0 to CLP=1 and
transmitted by this VPL."
::= { atmVcIntervalEntry 20 }
atmVcIntervalPCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum traffic rate encountered in the
last interval of the VC connection (monitored once a second)
encountered by an ATM interface/VC in one of the previous 96,
individual 15 minute, intervals."
::= { atmVcIntervalEntry 21 }
atmVcIntervalSCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The average traffic rate during the last interval
of the VC connection, encountered by an ATM interface/VC
in one of the previous 96, individual 15 minute, intervals."
::= { atmVcIntervalEntry 22 }
atmVcIntervalMCR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"MCR - The minimum traffic rate encountered in the last
interval of the VC connection (monitored once a second)
encountered by an ATM interface/VC in one of the previous 96,
individual 15 minute, intervals."
::= { atmVcIntervalEntry 23 }
atmVcIntervalShaperTotalDiscards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of cells (CLP0 and CLP1) discarded
due to congestion by the traffic shaper."
::= { atmVcIntervalEntry 24 }
atmVcIntervalShaperClp0Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP0 cells discarded
due to congestion by the traffic shaper."
::= { atmVcIntervalEntry 25 }
atmVcIntervalShaperClp1Discards OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of CLP1 cells discarded
due to congestion by the traffic shaper."
::= { atmVcIntervalEntry 26 }
-- The ATM VC Interval Table for Performance Management
-- which contains various statistics
-- collected by each ATM Interface/VC over the previous 24
-- hours of operation. The past 24 hours are broken into 96
-- completed 15 minute intervals.
atmVcPMIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM Vc Interval table for Performance Management."
::= { atmVcPerformance 4 }
--atmCESAAL1StatsTable OBJECT IDENTIFIER ::= {atmVcPerformance 5} (see hybCES.txt)
atmVcPMIntervalEntry OBJECT-TYPE
SYNTAX AtmVcPMIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM Vc Interval table for Performance
Management."
INDEX { ifIndex, atmVcPMIntervalVpi,
atmVcPMIntervalVci, atmVcPMIntervalDir, atmVcPMIntervalNumber }
::= { atmVcPMIntervalTable 1 }
AtmVcPMIntervalEntry ::=
SEQUENCE {
atmVcPMIntervalVpi
Integer32,
atmVcPMIntervalVci
Integer32,
atmVcPMIntervalDir
INTEGER,
atmVcPMIntervalNumber
Integer32,
atmVcPMIntervalTxClp01
Gauge32,
atmVcPMIntervalTxClp0
Gauge32,
atmVcPMIntervalRxClp01
Gauge32,
atmVcPMIntervalRxClp0
Gauge32,
atmVcPMIntervalErroredCells
Gauge32,
atmVcPMIntervalLostCells
Gauge32,
atmVcPMIntervalMisinsertedCells
Gauge32,
atmVcPMIntervalECB
Gauge32,
atmVcPMIntervalSECB
Gauge32,
atmVcPMIntervalES
Gauge32,
atmVcPMIntervalSES
Gauge32,
atmVcPMIntervalUAS
Gauge32,
atmVcPMIntervalQuality
INTEGER,
atmVcPMIntervalLastDayQuality
INTEGER
}
atmVcPMIntervalVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the VCL."
::= { atmVcPMIntervalEntry 1 }
atmVcPMIntervalVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the VCL."
::= { atmVcPMIntervalEntry 2 }
atmVcPMIntervalDir OBJECT-TYPE
SYNTAX INTEGER {forward(2),
backward(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of Performance Management."
::= { atmVcPMIntervalEntry 3 }
atmVcPMIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmVcPMIntervalEntry 4 }
atmVcPMIntervalTxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0+1 cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 5 }
atmVcPMIntervalTxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted
CLP 0 cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 6 }
atmVcPMIntervalRxClp01 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0+1 cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 7 }
atmVcPMIntervalRxClp0 OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received
CLP 0 cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 8 }
atmVcPMIntervalErroredCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 9 }
atmVcPMIntervalLostCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Lost
cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 10 }
atmVcPMIntervalMisinsertedCells OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Misinserted
cells, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 11 }
atmVcPMIntervalECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of ECBs
encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 12 }
atmVcPMIntervalSECB OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of SECBs
encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 13 }
atmVcPMIntervalES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 14 }
atmVcPMIntervalSES OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Severely
Errored Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 15 }
atmVcPMIntervalUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Unavailable
Seconds, encountered by an ATM
interface/VC in one of the previous 96, individual 15
minute, intervals."
::= { atmVcPMIntervalEntry 16 }
atmVcPMIntervalQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), unacceptable(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per interval is superior to
the atmNteUPLTCR value, the quality of service of
the interval is declared as unacceptable."
DEFVAL { normal }
::= { atmVcPMIntervalEntry 17}
atmVcPMIntervalLastDayQuality OBJECT-TYPE
SYNTAX INTEGER { normal(2), degraded(4) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" If the number of errors per 24 hours is superior to
the atmNteDPLTCR value, the quality of service of
the day is declared as degraded."
DEFVAL { normal }
::= { atmVcPMIntervalEntry 18}
-- VC QoS Table
atmVcQoSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VP QoS table."
::= { atmVcPerformance 6 }
atmVcQoSEntry OBJECT-TYPE
SYNTAX AtmVcQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VP table."
INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcQoSPeriodRef }
::= { atmVcQoSTable 1 }
AtmVcQoSEntry ::=
SEQUENCE {
atmVcQoSPeriodRef INTEGER,
atmVcQoSElapsedTime Integer32,
atmVcQoSUAS Gauge32
}
atmVcQoSPeriodRef OBJECT-TYPE
SYNTAX INTEGER
{
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
2 objects refer to.
currentPeriod - the period since last systemResetAllStatsCmd received or
since Start-up (if no systemResetAllStatsCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
- If only one command occurred since Start-up: the period between
Start-up and last command.
- If no command occurred since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { atmVcQoSEntry 1 }
atmVcQoSElapsedTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Elapsed Time in seconds.
- for atmVcQoSPeriodRef = currentPeriod:
The period since last systemResetAllStatsCmd received or since Start-up
(if no systemResetAllStatsCmd was received since Start-up) until now.
- for atmVcQoSPeriodRef = lastPeriod:
The value of atmVcQoSElapsedTime when last systemResetAllStatsCmd
was received."
::= { atmVcQoSEntry 2 }
atmVcQoSUAS OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of Unavailable Seconds for the reference period (atmVcQoSPeriodRef)."
::= { atmVcQoSEntry 3 }
-- VC PM QoS Table
atmVcPMQoSTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcPMQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The PM VC QoS table."
::= { atmVcPerformance 7 }
atmVcPMQoSEntry OBJECT-TYPE
SYNTAX AtmVcPMQoSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the VC PM QoS table."
INDEX { ifIndex, atmVclVpi, atmVclVci, atmVcPMQoSDirection ,atmVcPMQoSPeriodRef }
::= { atmVcPMQoSTable 1 }
AtmVcPMQoSEntry ::=
SEQUENCE {
atmVcPMQoSDirection INTEGER,
atmVcPMQoSPeriodRef INTEGER,
atmVcPMQoSCLR Gauge32,
atmVcPMQoSCER Gauge32,
atmVcPMQoSCMR Gauge32
}
atmVcPMQoSDirection OBJECT-TYPE
SYNTAX INTEGER
{
forward(2),
backward(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The direction of performance management."
::= { atmVcPMQoSEntry 1 }
atmVcPMQoSPeriodRef OBJECT-TYPE
SYNTAX INTEGER
{
currentPeriod (1),
lastPeriod (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object is an index that specifies which period of time, the next
5 objects refer to.
currentPeriod - the period since last systemResetAllStatsCmd received or
since Start-up (if no systemResetAllStatsCmd was received since
Start-up) until now.
lastPeriod - the period between last two commands of systemResetAllStatsCmd.
- If only one command occurred since Start-up: the period between
Start-up and last command.
- If no command occurred since Start-up: this period will not
actually exist. In this case, he following 5 objects will be 0."
::= { atmVcPMQoSEntry 2 }
atmVcPMQoSCLR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Loss Ratio counter for the reference period (atmVcPMQoSPeriodRef)-
defined in accordance with I.356 , in %.
The value will be multipuled by 100."
::= { atmVcPMQoSEntry 3 }
atmVcPMQoSCER OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Error Ratio counter for the reference period (atmVcPMQoSPeriodRef)
defined in accordance with I.356 , in %.
The value will be multipuled by 100."
::= { atmVcPMQoSEntry 4 }
atmVcPMQoSCMR OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Miss-insertion Ratio counter for the reference period (atmVcPMQoSPeriodRef)
defined in accordance with I.356 , cells/sec ."
::= { atmVcPMQoSEntry 5 }
--VC Shaper Statistics Table
atmVcShaperStatTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcShaperStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ATM VC shaper statistics table."
::= { atmVcPerformance 8 }
atmVcShaperStatEntry OBJECT-TYPE
SYNTAX AtmVcShaperStatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the ATM VC shaper statistics table."
INDEX { ifIndex, atmVclVpi, atmVclVci }
::= { atmVcShaperStatTable 1 }
AtmVcShaperStatEntry ::=
SEQUENCE {
atmVcShaperDiscarded Counter32,
atmVcShaperOccupation Integer32,
atmVcShaperMaxOccupation Integer32,
atmVcShaperLevel INTEGER,
atmVcShaperEpdDropped Counter32,
atmVcShaperTotalEpdDropped Counter32
}
atmVcShaperDiscarded OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that were discarded in the shaper on that VCC due
to buffer overflow. This counter counts till it reaches its MAX value
(20 bits) and then rolls over."
::= { atmVcShaperStatEntry 1 }
atmVcShaperOccupation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that are currently stored in the buffer.
This parameter is limited to 20 bits."
::= { atmVcShaperStatEntry 2}
atmVcShaperMaxOccupation OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Maximum number of Cells that were stored in the buffer,
since this VC was activated. This parameter is limited to 20 bits."
::= { atmVcShaperStatEntry 3}
atmVcShaperLevel OBJECT-TYPE
SYNTAX INTEGER {
empty (1),
full (2),
below (3),
above (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The occupation of the buffer according to a predefined threshold.
empty - buffer is Empty
full - buffer is Full
below - buffer is Below the threshold
above - buffer is Above the threshold. This is also the trigger to
start EPD\PPD mechanism, if set for the VCC."
::= { atmVcShaperStatEntry 4}
atmVcShaperEpdDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of Cells that were dropped in the shaper on that VCC
due to EPD\PPD mechanism in the last second.
This parameter is limited to 24 bits.
Applicable for a EPD/PPD VC only."
::= { atmVcShaperStatEntry 5}
atmVcShaperTotalEpdDropped OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Total number of Cells that were dropped in the shaper on that
VPC due to EPD\PPD mechanism in the last 15 minutes. This counter
automatically reset itself every 15 minutes.
Applicable for a EPD/PPD VC only."
::= { atmVcShaperStatEntry 6}
-- New
-- The agent will keep in this group the date & time corresponding to each interval.
atmIntervalDateTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIntervalDateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The agent will keep in this group the date & time
corresponding to each interval."
::= {atmPerfHistory 3}
atmIntervalDateEntry OBJECT-TYPE
SYNTAX AtmIntervalDateEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The date & time for the given interval."
INDEX { atmIntervalDateInterval }
::= { atmIntervalDateTable 1 }
AtmIntervalDateEntry ::=
SEQUENCE {
atmIntervalDateInterval
Integer32,
atmIntervalDateDate
DisplayString,
atmIntervalDateTime
DisplayString
}
atmIntervalDateInterval OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The interval number defining this entry."
::= { atmIntervalDateEntry 1}
atmIntervalDateDate OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date corresponding to this interval."
::= { atmIntervalDateEntry 2}
atmIntervalDateTime OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time corresponding to this interval."
::= { atmIntervalDateEntry 3}
--atmNte OBJECT IDENTIFIER ::= {radAtm 3}
atmNteSys OBJECT IDENTIFIER ::= {atmNte 1}
atmNteSysConfig OBJECT IDENTIFIER ::= {atmNteSys 1}
atmNteManagerTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Manager Table includes all the NMSs that
receive traps from this agent. A single manager
can receive traps on more than one PVC. The agent
will set implicitly the correct ifIndex, VPI, VCI
values to all relevant entries in the table when
the user changes them for one of the PVCs."
::= { atmNteSysConfig 1 }
atmNteManagerEntry OBJECT-TYPE
SYNTAX AtmNteManagerEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single manager and the PVC for receiving traps."
INDEX { atmNteManagerIP, atmNteManagerPvc}
::= { atmNteManagerTable 1 }
AtmNteManagerEntry ::=
SEQUENCE {
atmNteManagerIP
IpAddress,
atmNteManagerPvc
Integer32,
atmNteManagerIfIndex
Integer32,
atmNteManagerVpi
Integer32,
atmNteManagerVci
Integer32,
atmNteManagerTrapMask
Integer32,
atmNteManagerRowStatus
RowStatus,
atmNteManagerNextHop
IpAddress,
atmNteManagerVlanSupport
INTEGER,
atmNteManagerVlanIdentifier
Integer32,
atmNteManagerVlanFramePriority
Integer32,
atmNteManagerAlarmTrapMask
OCTET STRING,
atmNteManagerConfigPorts
Integer32
}
atmNteManagerIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address of the NMS."
::= { atmNteManagerEntry 1 }
atmNteManagerPvc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A PVC index. The range is 1..8. There are four PVCs
on the User Port and four PVCs on the Network Port.
The default VPI, VCI values are specified below."
::= { atmNteManagerEntry 2 }
atmNteManagerIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ATM interface index of the management port."
::= { atmNteManagerEntry 3 }
atmNteManagerVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VPI of the management VCL. Default: 0."
::= { atmNteManagerEntry 4 }
atmNteManagerVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VCI of the management VCL. Defaults: 32,33,34,35."
::= { atmNteManagerEntry 5 }
atmNteManagerTrapMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this attribute determines the type of traps the
agent should mask and not send to this NMS. The
value is differently determined for different products. There are
mainly two methods:
- an integer number, specifying the traps' severity.
- a sum of 2**n, where n is a bit assigned to a certain
masked trap group.
User should consult the product specification, to find out
the method employed."
::= { atmNteManagerEntry 6 }
atmNteManagerRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= {atmNteManagerEntry 7}
atmNteManagerNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is relevant to Ethernet out of band
host only (PVC=10).
The Next Hop IP address of the entry route."
::= { atmNteManagerEntry 8 }
atmNteManagerVlanSupport OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN support (Tagging).
no - No support to VLAN.
yes - 4 VLAN bytes will be added to the frame."
::= { atmNteManagerEntry 9}
atmNteManagerVlanIdentifier OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN ID. Range is 0..4095."
::= { atmNteManagerEntry 10 }
atmNteManagerVlanFramePriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN Frame priority.Range is 0..7."
::= { atmNteManagerEntry 11 }
atmNteManagerAlarmTrapMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The value of this object determines the alarm traps that the
agent should mask and not send to this NMS.
The value is an Octet String, where each bit is assigned to a certain
trap.
If the bit = 1, the trap will be masked.
If the bit = 0, the trap will not be masked.
More details on the masked traps exist in the product specification.
For products that do not mask specific traps, the value of the bits will be 0."
::= { atmNteManagerEntry 12 }
atmNteManagerConfigPorts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable defines from which port/s this manager can configure the device.
For IPmux 11 the value of this variable will be according to the ports
combination:
Network =1
User1=2
User2=4
(For Example: All ports = 7)."
::= { atmNteManagerEntry 13 }
atmNteUPLTCR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Unacceptable ES Limit threshold for Performance Management."
::= {atmNteSysConfig 2}
atmNteDPLTCR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Degraded ES Limit threshold for Performance Management."
::= {atmNteSysConfig 3}
atmNteSysLogClearAll OBJECT-TYPE
SYNTAX INTEGER { off(2), clear(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the variable to clear(3) removes all entries in the
Log Buffer of the agent. The agent will immediately reset
the variable to off(2)."
::= {atmNteSysConfig 4}
atmNteUSESLTCR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Unacceptable SES Limit threshold for Performance Management."
::= {atmNteSysConfig 5}
atmNteDSESLTCR OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Degraded ES Limit threshold for Performance Management."
::= {atmNteSysConfig 6}
atmNteProtection OBJECT IDENTIFIER ::= { atmNteSysConfig 8 }
atmNteProtectionMode OBJECT-TYPE
SYNTAX INTEGER {
off (1),
mspOn (2),
pathOn (3),
mspUniOn (4),
mspOneToN (5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Protection Mode.
MspOn - Multiplex section protection.
pathOn - High order path protection.
mspUniOn - Multiplex section Uni-directional protection.
mspOneToN - Multiplex section protection."
::= { atmNteProtection 1 }
atmNteProtectionWorkingLink OBJECT-TYPE
SYNTAX INTEGER {
trunk1(2),
trunk2(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects the working link when atmNteProtectionMode is off."
::= { atmNteProtection 2 }
atmNteProtectionSwitchLink OBJECT-TYPE
SYNTAX INTEGER {
off(1),
forceSwitch(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ForceSwitch - will force Switching from the working link to the backup link.
Afterwards the agent will set atmNteProtectionSwitchLink back to off(1).
atmNteProtectionMode must be either mspOn or pathOn."
::= { atmNteProtection 3 }
atmNteConfOam OBJECT IDENTIFIER ::= { atmNteSysConfig 9 }
atmNteConfOamSupport OBJECT-TYPE
SYNTAX INTEGER {
intermediate(1),
segmentTermination(2),
endToEndTermination(3),
vpEndToEndVcSegment(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"OAM support mode, which determines the device location
in a segment wise."
::= { atmNteConfOam 1 }
atmNteConfOamTransmission OBJECT IDENTIFIER ::= { atmNteConfOam 2 }
atmNteConfOamAIS OBJECT-TYPE
SYNTAX INTEGER {
none(1),
user(2),
network(3),
both(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines if a F4 segment OAM cell is transmitted due
to problems in the other port, i.e. physical layer
alarm or F4 defect. This is valid only when the ACE101
has ATM UNI interfaces in both sides and is configured
for 'Non-Intrusive' mode.
none - AIS is not sent to any of the ports.
user - F4 AIS will be sent toward the user when defect
is detected in the network port.
network - F4 AIS will be sent toward the network when
defect is detected in the user port.
both - F4 AIS will be sent toward the network when defect
is detected in the user port and toward the user
when defect is detected in the network port."
::= { atmNteConfOamTransmission 1 }
atmNteConfOamRDI OBJECT-TYPE
SYNTAX INTEGER {
none(1),
user(2),
network(3),
both(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Defines if an F4 OAM RDI cell is transmitted due to
physical layer problems in the port (in addition to
F4 RDI cells transmitted due to ATM layer problems).
The type of F4 RDI (Segment or End-to-End) is according
to the ACE-101 OAM mode.
For example, If it is enabled for Network port, then
physical layer defect will initiate the transmission
of F4 RDI cell back to the trunk."
::= { atmNteConfOamTransmission 2 }
atmNteConfOamAddressing OBJECT IDENTIFIER ::= { atmNteConfOam 3 }
atmNteConfLoopbackAddMode OBJECT-TYPE
SYNTAX INTEGER{
off(1),
on(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Loopback addressing mode.
on - will enable loopback addressing.
off - will disable loopback addressing."
::= { atmNteConfOamAddressing 1 }
atmNteConfLoopbackSourceAdd OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2..20))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Loopback source address. This field is relevant when
atmNteConfOamAddMode is on."
::= { atmNteConfOamAddressing 2 }
--OAM Table
atmNteConfOamIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteConfOamIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"OAM support per ATM interface."
::= { atmNteConfOam 4 }
atmNteConfOamIfEntry OBJECT-TYPE
SYNTAX AtmNteConfOamIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { ifIndex }
::= { atmNteConfOamIfTable 1 }
AtmNteConfOamIfEntry ::=
SEQUENCE {
atmNteConfOamIfAisRdi INTEGER
}
atmNteConfOamIfAisRdi OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter controls the generation of F4/F5
AIS and RDI due to lower order problems such as physical
layer problems.
For AIS: Defines if F4/F5 AIS cell is transmitted due
to problems such as physical layer alarm or F4/F5 defect.
This is applicable for all ports .
off - Problems in this port will not trigger F4/F5 AIS
transmition to the ajacent port (e.g. from USER to
NETWORK) of a VPC/VCC.
on - Problems in this port will trigger F4/F5 AIS
transmition to the ajacent port (e.g. from USER
to NETWORK) of a VPC/VCC.
For RDI: Defines if F4/F5 RDI cell will be transmitted due to
physical layer problems in that port (in addition to
F4/F5 RDI cells transmitted due to ATM layer problems).
For example, If it is enabled for Network port, then
physical layer defect will initiate the transmission
of F4/F5 RDI cell back to the trunk.
The type of F4/F5 (Segment or End-to-End) is according
to the configuration of the VPC/VCC."
::= { atmNteConfOamIfEntry 1 }
atmNteConfCAC OBJECT IDENTIFIER ::= { atmNteSysConfig 10 }
atmNteConfCACMode OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"CAC support mode.
For ACE2002, the following are the applicable values:
disable(1), enable(2), 10 - 1000."
::= { atmNteConfCAC 1 }
atmNteHostIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteHostIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Host IP interface table."
::= { atmNteSysConfig 11 }
atmNteHostIfEntry OBJECT-TYPE
SYNTAX AtmNteHostIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { atmNteHostPvcIndex }
::= { atmNteHostIfTable 1 }
AtmNteHostIfEntry ::=
SEQUENCE {
atmNteHostPvcIndex
Integer32,
atmNteHostIP
IpAddress,
atmNteHostMask
IpAddress,
atmNteHostAtmIfIndex
Integer32,
atmNteHostVpi
Integer32,
atmNteHostVci
Integer32,
atmNteHostRowStatus
RowStatus,
atmNteHostRdnVpi
Integer32,
atmNteHostRdnVci
Integer32,
atmNteHostDefaultNextHop
IpAddress,
atmNteHostVlanTagging
INTEGER,
atmNteHostDefaultVlanID
Integer32,
atmNteHostDefaultVlanPriority
Integer32
}
atmNteHostPvcIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A PVC index. The range is 1..10."
::= { atmNteHostIfEntry 1 }
atmNteHostIP OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface IP address."
::= { atmNteHostIfEntry 2 }
atmNteHostMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface subnet mask."
::= { atmNteHostIfEntry 3 }
atmNteHostAtmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ATM interface index. Will be 1
for user port, and 2 for network port."
::= { atmNteHostIfEntry 4 }
atmNteHostVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VPI of the PVC connected to that host interface."
::= { atmNteHostIfEntry 5 }
atmNteHostVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VCI of the PVC connected to that host interface."
::= { atmNteHostIfEntry 6 }
atmNteHostRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { atmNteHostIfEntry 7 }
atmNteHostRdnVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VPI of the redundant management VCL.
This parameter is applicable only if atmNteRdnManagement=enable(3). "
::= { atmNteHostIfEntry 8 }
atmNteHostRdnVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VCI of the redundant management VCL.
This parameter is applicable only if atmNteRdnManagement=enable(3). "
::= { atmNteHostIfEntry 9 }
atmNteHostDefaultNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The host interface Default Next Hop address.
This address will be used as default next hop for
every Bundle mapped to this Host."
::= { atmNteHostIfEntry 10 }
atmNteHostVlanTagging OBJECT-TYPE
SYNTAX INTEGER {
no (2),
yes (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"VLAN Tag support.
no - No support to VLAN.
yes - 4 VLAN bytes will be added
to each frame connected to this Host."
::= { atmNteHostIfEntry 11 }
atmNteHostDefaultVlanID OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default VLAN ID of this Host."
::= { atmNteHostIfEntry 12 }
atmNteHostDefaultVlanPriority OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Default VLAN priority for this Host."
::= { atmNteHostIfEntry 13 }
atmNteShaperMode OBJECT-TYPE
SYNTAX INTEGER {
normal (1),
group (2),
aggregate (3),
vpInbandMng (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Shaper Mode.
vpInbandMng - Vcc within a Vp for management."
::= { atmNteSysConfig 12 }
atmNteOutputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Aggregate shaping output rate in Cells per Seconds units.
Default value is the Network port rate."
::= { atmNteSysConfig 13 }
atmNteTosMode OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"TOS Mode."
::= { atmNteSysConfig 14 }
atmNteTosMask OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determines the seqence of bits that will be used for TOS.
For ACE101 this parameter is applicable only if atmNteTosMode = enable.
Valid only for IP-TOS process."
::= { atmNteSysConfig 15 }
atmNteTosHighPriority OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(8))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Priorities options are High or Low.
High priority will be represented by bit = 1.
Low priority will be represented by bit = 0.
Each TOS value will be represented by the bit location.
For example, the string for TOS 2, 9, 15 with High priority,
will be:
|0000 0000|... ...|0000 0000|1000 0010|0000 0100|
...98 7654 3210 (Bit #)
8 ... 3 2 1 (Byte #)."
::= { atmNteSysConfig 16 }
atmNtePlugAndPlayActivity OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
offline (2),
online (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Activity control for Manager Plug And Play.
disable - disable the feature.
offline - Automatic learn IP address into offline memory.
online - Automatic learn IP address into online memory. "
::= { atmNteSysConfig 17 }
atmNteSlotUsage OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
user (2),
network (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Applicable to ace2002. Slot 2 might be configured
as user slot or as network slot."
::= { atmNteSysConfig 18 }
atmNteConnectionsMaxNumber OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
max1024 (2),
max2048 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The MAX number of connections supported by system.
Setting this parameter will affect the number of MAX intervals supported.
This parameter will affect the system only after reset.
Changing this parameter from high value to a low value, will be accepted by agent
only if the actual used connection <= the desired connection Max number.
Applicable to ace2002. "
::= { atmNteSysConfig 19 }
atmNteDefaultVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Vpi for management."
::= { atmNteSysConfig 20 }
atmNteDefaultVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Vci for management."
::= { atmNteSysConfig 21 }
atmNteReservedVpi OBJECT-TYPE
SYNTAX Integer32 (0..255)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Internal use VPI, where shaperMode=vpInbandMng."
::= { atmNteSysConfig 22 }
atmNteRdnManagement OBJECT-TYPE
SYNTAX INTEGER {
disabled (2),
enabled (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The redundancy management status."
::= { atmNteSysConfig 23 }
atmNtePlugAndPlayIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The ifIndex of the Plug and Play VCC."
::= { atmNteSysConfig 24 }
atmNteLoopbackTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Loopback state timeout in minutes. A value of
zero means no timeout (for ever). Default is 5 min."
::= { atmNteSysConfig 25 }
atmNteOamTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is a static table, which is created by agent once
upon initialization. The created entries are actually, only the
supported OAM features.
This table enables addition of new features by adding new entries
rather than adding scalar parameters.
An OAM feature is defined by the indexes values combination."
::= { atmNteSysConfig 26 }
atmNteOamEntry OBJECT-TYPE
SYNTAX AtmNteOamEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the OAM table.
Each entry in this table will indicate a special OAM."
INDEX {atmNteOamMode, atmNteOamCellType, atmNteOamLevel}
::= { atmNteOamTable 1 }
AtmNteOamEntry ::=
SEQUENCE {
atmNteOamMode
INTEGER,
atmNteOamCellType
INTEGER,
atmNteOamLevel
INTEGER,
atmNteOamEnable
INTEGER
}
atmNteOamMode OBJECT-TYPE
SYNTAX INTEGER
{
endToEnd (1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The OAM cell path.
endToEnd(1) - the entire path."
::= { atmNteOamEntry 1 }
atmNteOamCellType OBJECT-TYPE
SYNTAX INTEGER
{
aisAndRdi (1),
loopback (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates a unique Indication Signal.
aisAndRdi(1) - Alarm Indication Signal (AIS) and
Remote Defect Indication (RDI) cell.
loopback(2) - Loopback cell."
::= { atmNteOamEntry 2 }
atmNteOamLevel OBJECT-TYPE
SYNTAX INTEGER
{
-- f4 (2),
f5 (3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The level of the OAM cell.
-- f4 (2) - VP level,
f5 (3) - VC level."
::= { atmNteOamEntry 3 }
atmNteOamEnable OBJECT-TYPE
SYNTAX INTEGER
{
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determines if the specified OAM cells
will be enabled."
::= { atmNteOamEntry 4 }
atmNteDefaultLoopbackThreshold OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Default OAM Loopback Failure Threshold value
that will be used for configuration."
::= { atmNteSysConfig 27 }
atmNteMaxBurstSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Maximum allowed burst size (cell units).
This object is applicable for each Physical port."
::= { atmNteSysConfig 28 }
atmNteGranularityFactor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter affects the granularity of the guaranteed
Rate (SCR+MCR) in spaced connection (cell/sec units).
It is also defines the minimum guaranteed rate in spaced
connection."
::= { atmNteSysConfig 29 }
atmNteTotalInputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the total input rate of the
device in cells/sec."
::= { atmNteSysConfig 30 }
atmNteTotalOutputRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates the total output rate of the
device in cells/sec."
::= { atmNteSysConfig 31 }
atmAlarmForwardingTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmAlarmForwardingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Alarm Forwarding Mechanism will be operated
for this table entries."
::= { atmNteSysConfig 32 }
atmAlarmForwardingEntry OBJECT-TYPE
SYNTAX AtmAlarmForwardingEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table is a pair of ports that
the Alarm Forwarding Mechanism is determined for."
INDEX { atmAlarmForwardingFailPort, atmAlarmForwardingToPort }
::= { atmAlarmForwardingTable 1 }
AtmAlarmForwardingEntry ::=
SEQUENCE {
atmAlarmForwardingFailPort
Integer32,
atmAlarmForwardingToPort
Integer32,
atmAlarmForwardingRowStatus
RowStatus,
atmAlarmForwardingFailureLevel
BITS,
atmAlarmForwardingRecoveryMode
INTEGER,
atmAlarmForwardingRecoveryCommand
INTEGER,
atmAlarmForwardingTimeFilterWindow
Unsigned32
}
atmAlarmForwardingFailPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index of the port on which a fail occurs."
::= { atmAlarmForwardingEntry 1 }
atmAlarmForwardingToPort OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An Index of the port that will be affected
upon the failure of the atmAlarmForwardingFailPort."
::= { atmAlarmForwardingEntry 2 }
atmAlarmForwardingRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= { atmAlarmForwardingEntry 3 }
atmAlarmForwardingFailureLevel OBJECT-TYPE
SYNTAX BITS{
physical (0),
atm (1)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the level of failure
that will operate the Alarm Forwarding Mechanism."
::= { atmAlarmForwardingEntry 4 }
atmAlarmForwardingRecoveryMode OBJECT-TYPE
SYNTAX INTEGER {
manual (1),
automatic (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the Recovery Mode.
manual - The user should stop the RDI transmission
by using the atmAlarmForwardingRecoveryCommand.
automatic - The RDI transmission will be automatically
stopped upon atmAlarmForwardingFailPort
recovery."
::= { atmAlarmForwardingEntry 5 }
atmAlarmForwardingRecoveryCommand OBJECT-TYPE
SYNTAX INTEGER {
off (2),
on (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is a command. It is applicable when
atmAlarmForwardingRecoveryMode = manual.
on - Will stop the RDI transmission. After setting to 'On'
the agent will set this parameter back to 'Off'."
::= { atmAlarmForwardingEntry 6 }
atmAlarmForwardingTimeFilterWindow OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter determines the Time Filter Window, meaning:
how much time (in seconds) should the alarm exist
in order to start the Alarm Forwarding operation."
::= { atmAlarmForwardingEntry 7 }
atmSysConfigCellTest OBJECT IDENTIFIER ::= { atmNteSysConfig 33 }
atmSysConfigCellTestPort OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An Index of the port on which the cell test
will be sent."
::= { atmSysConfigCellTest 1 }
atmSysConfigCellTestVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VPI on which the cell test will be sent."
::= { atmSysConfigCellTest 2 }
atmSysConfigCellTestVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The VCI on which the cell test will be sent."
::= { atmSysConfigCellTest 3 }
atmSysConfigCellTestPti OBJECT-TYPE
SYNTAX INTEGER {
user (1),
oamSegment (2),
oamEndToEnd (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The cell type."
::= { atmSysConfigCellTest 4 }
atmSysConfigCellTestClp OBJECT-TYPE
SYNTAX INTEGER {
clp0 (1),
clp1 (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The type of the Cell."
::= { atmSysConfigCellTest 5 }
atmSysConfigCellTestOamType OBJECT-TYPE
SYNTAX INTEGER {
ais (1),
rdi (2),
cc (3),
lb (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The OAM type of the Cell. This object is applicable
if atmSysConfigCellTestPti = oamSegment/oamEndToEnd ."
::= { atmSysConfigCellTest 6 }
atmSysConfigCellTestPayload OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The payload of the cell. For OAM cell the payload
is set automatically to 6A."
::= { atmSysConfigCellTest 7 }
atmSysConfigCellTestQuantity OBJECT-TYPE
SYNTAX Integer32 (1..10000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Quantity of cells to send."
::= { atmSysConfigCellTest 8 }
atmSysConfigCellTestSendCmd OBJECT-TYPE
SYNTAX INTEGER {
off (2),
send (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the variable to send(3) perfroms cell test.
The agent will immediately reset the variable to off(2)."
::= { atmSysConfigCellTest 9 }
-- The ATM VP Cross Connect Extension Table
atmVpCrossConnectExtenTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpCrossConnectExtenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An extension to the ATM VP Cross Connect table
(RFC2515 - atmVpCrossConnectTable)."
::= { atmNteSysConfig 34 }
atmVpCrossConnectExtenEntry OBJECT-TYPE
SYNTAX AtmVpCrossConnectExtenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
AUGMENTS { atmVpCrossConnectEntry }
::= { atmVpCrossConnectExtenTable 1 }
AtmVpCrossConnectExtenEntry ::= SEQUENCE {
atmVpCrossConnectName SnmpAdminString
}
atmVpCrossConnectName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Connection's name."
::= { atmVpCrossConnectExtenEntry 1 }
-- The ATM VC Cross Connect Extension Table
atmVcCrossConnectExtenTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcCrossConnectExtenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An extension to the ATM VC Cross Connect table
(RFC2515 - atmVcCrossConnectTable)."
::= { atmNteSysConfig 35 }
atmVcCrossConnectExtenEntry OBJECT-TYPE
SYNTAX AtmVcCrossConnectExtenEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
AUGMENTS { atmVcCrossConnectEntry }
::= { atmVcCrossConnectExtenTable 1 }
AtmVcCrossConnectExtenEntry ::= SEQUENCE {
atmVcCrossConnectName SnmpAdminString
}
atmVcCrossConnectName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..64))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Connection's name."
::= { atmVcCrossConnectExtenEntry 1 }
-- The Congestion Thresholds Configuration Table
atmCongestionThresholdTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCongestionThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Congestion Thresholds Configuration Table."
::= { atmNteSysConfig 36 }
atmCongestionThresholdEntry OBJECT-TYPE
SYNTAX AtmCongestionThresholdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the table."
INDEX { atmCongestionThresholdType, atmCongestionThresholdServiceCategory }
::= { atmCongestionThresholdTable 1 }
AtmCongestionThresholdEntry ::= SEQUENCE {
atmCongestionThresholdType INTEGER,
atmCongestionThresholdServiceCategory INTEGER,
atmCongestionThresholdValue Integer32
}
atmCongestionThresholdType OBJECT-TYPE
SYNTAX INTEGER
{
global (1),
clp01 (2),
clp1Upper (3),
clp1Lower (4)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Congestion Threshold Type."
::= { atmCongestionThresholdEntry 1 }
atmCongestionThresholdServiceCategory OBJECT-TYPE
SYNTAX INTEGER
{
cbr (1),
rtVbr (2),
ubrPlus (3),
ubr (4)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Congestion Threshold Service Category."
::= { atmCongestionThresholdEntry 2 }
atmCongestionThresholdValue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Congestion Threshold Value."
::= { atmCongestionThresholdEntry 3 }
atmNteQosMode OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
multipleVc (2),
singleVc (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the QoS Mode.
disable(1) - QoS is disabled.
multipleVc(2) - QoS is enabled and
multiple VCs can be bound per bridge port.
singleVc(3) - QoS is enabled and
only single VC can be bound per bridge port."
::= { atmNteSysConfig 37 }
atmNteSysInfo OBJECT IDENTIFIER ::= {atmNteSys 2}
atmNteIdTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The IDs of the cards and of the system."
::= { atmNteSysInfo 1 }
atmNteIdEntry OBJECT-TYPE
SYNTAX AtmNteIdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { atmNteIdIndex}
::= { atmNteIdTable 1 }
AtmNteIdEntry ::=
SEQUENCE {
atmNteIdIndex
Integer32,
atmNteUnitId
Integer32,
atmNteUnitVersion
DisplayString,
atmNteCardType
INTEGER,
atmNteCardStatus
INTEGER,
atmNteCardCmd
INTEGER,
atmNteProgCardType
INTEGER
}
atmNteIdIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An Index of the Unit ID table.
The following units have IDs in this table:
1 - System
2 - ATM Board
3 - User Card
4 - Trunk 1 card
5 - Trunk 2 card
6 - Shaper
7 - Clock Unit
8 - Slot 1 card
9 - Slot 2 card
10 - Slot 3 card
11 - Slot 4 card
12 - Fan1
13 - Fan2
14 - Control Unit."
::= { atmNteIdEntry 1 }
atmNteUnitId OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ID of the Unit.
For index = 6, the id will describe the validity
of a shaper in the system: 0 - Shaper Not exist
1 - Shaper exist.
For index = 7, the id will describe the validity
of a clock in the system: 0 - Clock Not exist
1 - Clock exist.
2- Clock exist but failed.
For index = 12,13 the id will describe the functionality
of a FAN1 : 0 - OK
1 - Failed."
::= { atmNteIdEntry 2 }
atmNteUnitVersion OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Hardware and Software version
of the module."
::= { atmNteIdEntry 3 }
atmNteCardType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
sc13mR155 (2),
st13sR155 (3),
st13lR155 (4),
utpR155 (5),
cxBncR155 (6),
e3 (7),
t3 (8),
e1 (9),
e1Ltu (10),
fc13lR155 (11),
fc13lhR155 (12),
fc15lhR155 (13),
fc13lE3 (14),
fc13lhE3 (15),
fc15lhE3 (16),
fc13lT3 (17),
fc13lhT3 (18),
fc15lhT3 (19),
t1 (20),
eth (21),
ethE1CesBnc (22),
ethE1CesRj45 (23),
ethT1CesRj45 (24),
e1CesRj45 (25),
e1CesBnc (26),
t1CesRj45 (27),
e14Ces (28),
e14CesRj45 (29),
t14CesRj45 (30),
hdlc4port (31),
hdlcE14CesBnc (32),
hdlcE14CesRj45 (33),
hdlcT14CesRj45 (34),
e1Rj45 (35),
e1Bnc (36),
ethE14CesBnc (37),
ethE14CesRj45 (38),
ethT14CesRj45 (39),
hdlc1portHssi (40),
hdlcHssiE14CesBnc (41),
hdlcHssiE14CesRj45 (42),
hdlcHssiT14CesRj45 (43),
e14ImaRj45 (44),
e14ImaBnc (45),
t14ImaRj45 (46),
ethE3CesBnc (47),
ethT3CesBnc (48),
smSf1R155 (49),
smSf2R155 (50),
sc13sR155 (51),
sc13lR155 (52),
utp25 (53),
sc13lhR155 (54),
sc15lhR155 (55),
sc13ljR155 (56),
sc13lhjR155 (57),
sc15lhjR155 (58),
e18Ces (59),
e18CesRj45 (60),
t18CesRj45 (61),
sc13mR622 (62),
-- st13sR622 (63),
-- st13lR622 (64),
-- utpR622 (65),
-- cxBncR622 (66),
-- fc13lR622 (67),
-- fc13lhR622 (68),
-- fc15lhR622 (69),
-- smSf1R622 (70),
-- smSf2R622 (71),
-- sc13sR622 (72),
sc13lR622 (73),
sc13lhR622 (74),
sc15lhR622 (75),
fr4Port (76),
t3j (77),
fr1Port (78),
hdlc1Port (79),
sc13mR155D (80),
sc13lR155D (81),
fc13lR155D (82),
st13lR155D (83),
sc13lhR155D (84),
fc13lhR155D (85),
st13lhR155D (86),
e18ImaBnc (87),
e18ImaRj45 (88),
t18ImaRj45 (89),
lanUtpE (90),
lanLc13lE (91),
lanLc13mE (92),
e14ImaRj45CfgMode (93),
e14ImaBncCfgMode (94),
t14ImaRj45CfgMode (95),
sc13mR155R (96), --Dual for Redundancy
sc13lR155R (97), --Dual for Redundancy
fc13lR155R (98), --Dual for Redundancy
st13lR155R (99), --Dual for Redundancy
sc13lhR155R (100), --Dual for Redundancy
fc13lhR155R (101), --Dual for Redundancy
st13lhR155R (102), --Dual for Redundancy
fEthUtpD (103),
fEthSmD (104),
fEthMmD (105),
e14CesRj45Unbal (106),
sc13mR155n (107),
sc13lR155n (108),
sc13lhR155n (109),
sc15lhR155n (110),
fc13lR155n (111),
fc13lhR155n (112),
fc15lhR155n (113),
st13lR155n (114),
lanUtp (115),
lanLc13l (116),
lanLc13m (117),
e1FrHdlc (118),
e1FrHdlcUnbal (119),
t1FrHdlc (120),
channelizedT3 (121), --for IP-MUX16
fc15lhR155D (122), --Dual STM-1
sc15lhR155D (123), --Dual STM-1
smSf1R155D (124), --Dual STM-1
smSf2R155D (125), --Dual STM-1
smSf3R155D (126), --Dual STM-1
fc15lhR155R (127), --Dual for Redundancy
sc15lhR155R (128), --Dual for Redundancy
smSf1R155R (129), --Dual for Redundancy
smSf2R155R (130), --Dual for Redundancy
smSf3R155R (131), --Dual for Redundancy
st13lhR155n (132), --New STM-1
smSf1R155n (133), --New STM-1
smSf2R155n (134), --New STM-1
smSf3R155n (135), --New STM-1
t18CesNg (136),
e18CesUnbalNg (137),
e18CesBalNg (138),
t14CesNg (139),
e14CesUnbalNg (140),
e14CesBalNg (141),
t18ImaUniNg (142),
e18ImaUniUnbalNg(143),
e18ImaUniBalNg (144),
t14ImaUniNg (145),
e14ImaUniUnbalNg(146),
e14ImaUniBalNg (147),
t1Ces (148),
e1CesUnbal (149),
e1CesBal (150),
switchedLan (151), --LAN card with ETH switch (usually 4 ports)
channelizedSts1 (152), --Channelized STS1 card (for IP-MUX16)
st13mR155 (153),
st13lhR155 (154),
st15lhR155 (155),
gigabitEthUtp (156),
gigabitEthSfp (157),
fastEthUtp (158),
main (251),
control (252),
fan (253),
unknown (254),
empty (255)
-- values 1000 and up are reserved
-- (used by atmNteProgCardType)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The card type."
::= { atmNteIdEntry 4 }
atmNteCardStatus OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
notActive (2),
active (3),
inProgress (4),
empty (5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Status of the card in the selected slot.
notActive - Connections are in NotReady state. No configuration is
available for the card. The access to the card HW is blocked.
This state is relevant for an extracted card, and for a case
in which the card was deactivated.
active - The module installed and functions. A card that in this state
can be configured.
inProgress - The status during proccessing of a command from atmNteCardCmd.
empty - No information is valid for the selected slot. This status is
relevant to a case in which the card configaration was deleted,
or in case in which a slot was empty since the device startup."
::= { atmNteIdEntry 5 }
atmNteCardCmd OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
deleteConfig (2),
deactivate (3),
activate (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Command on the card that is installed in the selected slot.
The commands are applicable according to the value of atmNteCardStatus.
See the specification document for details.
deleteConfig - Deletes the card configuration.
deactivate - All the connections state will be changed to NotReady. The card
configuration will be blocked.
activate - Does the same as done upon card insertion: Initiates the relevant
parameters, activates the physical layer, ATM layer and logical
layer."
::= { atmNteIdEntry 6 }
atmNteProgCardType OBJECT-TYPE
SYNTAX INTEGER {
-- values 1...1000 (if needed) should be used
-- the same as in atmNteCardType
main (251),
control (252),
fan (253),
empty (255),
atm155 (1001),
eth (1002)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The programmed card type."
::= { atmNteIdEntry 7 }
atmSysPSunits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of power supply units."
::= { atmNteSysInfo 2 }
atmSysPSunitsInUse OBJECT-TYPE
SYNTAX INTEGER { ps1(2), ps2(3) }
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The main power supply in this unit."
::= { atmNteSysInfo 3 }
atmSysFanUnits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of fan units."
::= { atmNteSysInfo 4 }
atmSysNetPrts OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of network ports."
::= { atmNteSysInfo 5 }
atmSysNetPrtInUse OBJECT-TYPE
SYNTAX INTEGER {
trunk1(2),
trunk2(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The network port in use."
::= { atmNteSysInfo 6 }
atmNteBridgingMode OBJECT-TYPE
SYNTAX INTEGER {
accessOnly(1),
accessAndSwitching (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bridging mode can be one of the following:
ATM <> Ethernet - Bridging is between the Ethernet
port and the ATM port (there is no bridging between VCs).
ATM <> Ethernet + ATM - Bridging is done both between
the Ethernet port and the ATM port and also between VCs."
::= { atmNteSysInfo 7}
atmSysStats OBJECT IDENTIFIER ::= { atmNteSysInfo 8 }
atmSysCurrentCdc OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Seconds in which cells dropped was occured in
the current 15 minutes interval."
::= { atmSysStats 1 }
atmSysIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmSysIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The system level Interval table."
::= { atmSysStats 2 }
atmSysIntervalEntry OBJECT-TYPE
SYNTAX AtmSysIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"."
INDEX { atmSysIntervalNumber }
::= { atmSysIntervalTable 1 }
AtmSysIntervalEntry ::=
SEQUENCE {
atmSysIntervalNumber
Integer32,
atmSysIntervalCdc
Gauge32
}
atmSysIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals are valid)."
::= { atmSysIntervalEntry 1 }
atmSysIntervalCdc OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Seconds in which cells dropped was occured in
15 minutes interval."
::= { atmSysIntervalEntry 2 }
atmNteEventType OBJECT-TYPE
SYNTAX INTEGER {
ps1NotActive (3),
ps1Active (4),
ps2NotActive (5),
ps2Active (6),
heatAlarmOff (7),
heatAlarmOn (8),
inputAlarm1Off (9),
inputAlarm1On (10),
inputAlarm2Off (11),
inputAlarm2On (12),
inputAlarm3Off (13),
inputAlarm3On (14),
inputAlarm4Off (15),
inputAlarm4On (16),
fan1Ok (17),
fan1Fail (18),
fan2Ok (19),
fan2Fail (20),
invalidLogin (21),
validLogin (22),
powerFailure (23),
writeToFlashFailure (24)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter identifies the event.
On - the problem exist.
Off - the problem not exist.
InvalidLogin - Invalid login on local console.
CorrectLogin - Successful login operation."
::= { atmNteSysInfo 9 }
atmNteIntervalMaxNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The MAX number of connections intervals supported by system.
This parameter value is a function of atmNteConnectionsMaxNumber
parameter.
This parameter should affect the threshold values selected by user.
Applicable to ace2002."
::= { atmNteSysInfo 10 }
atmNteAlarmType OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable(1),
ais(2),
rdi(3),
continuityLoss(4),
loopback(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the type of the alarm."
::= { atmNteSysInfo 11 }
atmNteLevel OBJECT-TYPE
SYNTAX INTEGER
{
vp(2),
vc(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies the ATM level."
::= { atmNteSysInfo 12 }
atmNteConnectionsNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object specifies a quantity of connections."
::= { atmNteSysInfo 13 }
atmNteTotalLb OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter counts the total number of end-points
that were configured with Loopback (LB)."
::= { atmNteSysInfo 14 }
atmNteTotalCc OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter counts the total number of end-points
that were configured with Continuity Check (CC)."
::= { atmNteSysInfo 15 }
atmNteTotalPm OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter counts the total number of end-points
that were configured with PM."
::= { atmNteSysInfo 16 }
--atmNtePrt OBJECT IDENTIFIER ::= {atmNte 2}
-- Changed
atmNteLoopback OBJECT IDENTIFIER ::= {atmNtePrt 2}
-- The loopback test consists of inserting special OAM cells. This test is started and stopped
-- upon operator request (by using MIB item atmVpConfLoopbackAdminStatus).
-- There are two tables per VP and two tables per VC: the measurements of the current 15 minutes,
-- and the measurement of the last 96 periods of 15 minutes.
atmLoopbackVpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLoopbackVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for an OAM VP loopback test."
::= {atmNteLoopback 1 }
atmLoopbackVpEntry OBJECT-TYPE
SYNTAX AtmLoopbackVpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table atmLoopbackVpTable."
INDEX {atmLoopbackVpIfIndex,atmLoopbackVpVpi}
::= {atmLoopbackVpTable 1}
AtmLoopbackVpEntry ::=
SEQUENCE {
atmLoopbackVpIfIndex Integer32,
atmLoopbackVpVpi Integer32,
atmLoopbackVpOperStatus INTEGER,
atmLoopbackVpCDV Integer32,
atmLoopbackVpAverageDelay Integer32,
atmLoopbackVpMaxDelay Integer32,
atmLoopbackVpMinDelay Integer32,
atmLoopbackVpErrSessions Integer32
}
atmLoopbackVpIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmLoopbackVpEntry 1}
atmLoopbackVpVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the OAM VPL."
::= {atmLoopbackVpEntry 2}
atmLoopbackVpOperStatus OBJECT-TYPE
SYNTAX INTEGER {
noActive(1),
inProgress(2),
failed(3),
endSuccessfully(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"-noActive(1) means that the loopback test has not been activated for this VP.
-inProgress(2) means that the test has been activated and there is currently no problem.
-failed(3) means there was problem during the test or after having stopped it
-endSuccessfully(4) means that the test was stopped and all was OK."
::= {atmLoopbackVpEntry 3}
atmLoopbackVpCDV OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Delay Variation for this sampling."
::= {atmLoopbackVpEntry 4}
atmLoopbackVpAverageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Average delay without including lost cells."
::= {atmLoopbackVpEntry 5}
atmLoopbackVpMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum delay without including lost cells."
::= {atmLoopbackVpEntry 6}
atmLoopbackVpMinDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Minimum delay."
::= {atmLoopbackVpEntry 7}
atmLoopbackVpErrSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errored Sessions. Will be updated once in 5 seconds."
::= {atmLoopbackVpEntry 8}
atmLoopbackVcTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLoopbackVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for an OAM VC loopback test."
::= {atmNteLoopback 2 }
atmLoopbackVcEntry OBJECT-TYPE
SYNTAX AtmLoopbackVcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmLoopbackVcIfIndex,atmLoopbackVcVpi,atmLoopbackVcVci}
::= {atmLoopbackVcTable 1}
AtmLoopbackVcEntry ::=
SEQUENCE {
atmLoopbackVcIfIndex Integer32,
atmLoopbackVcVpi Integer32,
atmLoopbackVcVci Integer32,
atmLoopbackVcOperStatus INTEGER,
atmLoopbackVcCDV Integer32,
atmLoopbackVcAverageDelay Integer32,
atmLoopbackVcMaxDelay Integer32,
atmLoopbackVcMinDelay Integer32,
atmLoopbackVcErrSessions Integer32
}
atmLoopbackVcIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmLoopbackVcEntry 1}
atmLoopbackVcVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the OAM VCL."
::= {atmLoopbackVcEntry 2}
atmLoopbackVcVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the OAM VCL."
::= {atmLoopbackVcEntry 3}
atmLoopbackVcOperStatus OBJECT-TYPE
SYNTAX INTEGER {
noActive(1),
inProgress(2),
failed(3),
endSuccessfully(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"-noActive(1) means that the loopback test has not been activated for this VP.
-inProgress(2) means that the test has been activated and there is currently no problem.
-failed(3) means there was problem during the test or after having stopped it
-endSuccessfully(4) means that the test was stopped and all was OK."
::= {atmLoopbackVcEntry 4}
atmLoopbackVcCDV OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Delay Variation for this sampling."
::= {atmLoopbackVcEntry 5}
atmLoopbackVcAverageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Average delay without including lost cells."
::= {atmLoopbackVcEntry 6}
atmLoopbackVcMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum delay without including lost cells."
::= {atmLoopbackVcEntry 7}
atmLoopbackVcMinDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum delay."
::= {atmLoopbackVcEntry 8}
atmLoopbackVcErrSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errored Sessions. Will be updated once in 5 seconds."
::= {atmLoopbackVcEntry 9}
-- Entirely New
atmLoopbackVpIvlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLoopbackVpIvlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for an OAM VP loopback test,
according interval number."
::= {atmNteLoopback 3 }
atmLoopbackVpIvlEntry OBJECT-TYPE
SYNTAX AtmLoopbackVpIvlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX { atmLoopbackVpIvlIfIndex, atmLoopbackVpIvlVpi, atmLoopbackVpIvlIvl }
::= { atmLoopbackVpIvlTable 1}
AtmLoopbackVpIvlEntry ::=
SEQUENCE {
atmLoopbackVpIvlIfIndex Integer32,
atmLoopbackVpIvlVpi Integer32,
atmLoopbackVpIvlIvl Integer32,
atmLoopbackVpIvlOperStatus INTEGER,
atmLoopbackVpIvlCDV Integer32,
atmLoopbackVpIvlAverageDelay Integer32,
atmLoopbackVpIvlMaxDelay Integer32,
atmLoopbackVpIvlMinDelay Integer32,
atmLoopbackVpIvlErrSessions Integer32
}
atmLoopbackVpIvlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= { atmLoopbackVpIvlEntry 1}
atmLoopbackVpIvlVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the OAM VPL."
::= { atmLoopbackVpIvlEntry 2}
atmLoopbackVpIvlIvl OBJECT-TYPE
SYNTAX Integer32(1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The relevant interval number."
::= { atmLoopbackVpIvlEntry 3}
atmLoopbackVpIvlOperStatus OBJECT-TYPE
SYNTAX INTEGER {
noActive(1),
inProgress(2),
failed(3),
endSuccessfully(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"-noActive(1) means that the loopback test has not been activated for this VP during this interval.
-inProgress(2) has no meaning for an ended interval.
-failed(3) means there was problem during the test or after having stopped it
-endSuccessfully(4) means that the test was OK."
::= { atmLoopbackVpIvlEntry 4}
atmLoopbackVpIvlCDV OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Delay Variation for this interval."
::= { atmLoopbackVpIvlEntry 5}
atmLoopbackVpIvlAverageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Average delay without including lost cells for this interval."
::= { atmLoopbackVpIvlEntry 6}
atmLoopbackVpIvlMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum delay without including lost cells for this interval."
::= { atmLoopbackVpIvlEntry 7}
atmLoopbackVpIvlMinDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum delay for this interval."
::= {atmLoopbackVpIvlEntry 8}
atmLoopbackVpIvlErrSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errored Sessions. Will be updated once in 5 seconds."
::= {atmLoopbackVpIvlEntry 9}
atmLoopbackVcIvlTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLoopbackVcIvlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for an OAM VC loopback test."
::= {atmNteLoopback 4 }
atmLoopbackVcIvlEntry OBJECT-TYPE
SYNTAX AtmLoopbackVcIvlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmLoopbackVcIvlIfIndex, atmLoopbackVcIvlVpi, atmLoopbackVcIvlVci, atmLoopbackVcIvlIvl }
::= {atmLoopbackVcIvlTable 1}
AtmLoopbackVcIvlEntry ::=
SEQUENCE {
atmLoopbackVcIvlIfIndex Integer32,
atmLoopbackVcIvlVpi Integer32,
atmLoopbackVcIvlVci Integer32,
atmLoopbackVcIvlIvl Integer32,
atmLoopbackVcIvlOperStatus INTEGER,
atmLoopbackVcIvlCDV Integer32,
atmLoopbackVcIvlAverageDelay Integer32,
atmLoopbackVcIvlMaxDelay Integer32,
atmLoopbackVcIvlMinDelay Integer32,
atmLoopbackVcIvlErrSessions Integer32
}
atmLoopbackVcIvlIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmLoopbackVcIvlEntry 1}
atmLoopbackVcIvlVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the OAM VCL."
::= {atmLoopbackVcIvlEntry 2}
atmLoopbackVcIvlVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the OAM VCL."
::= {atmLoopbackVcIvlEntry 3}
atmLoopbackVcIvlIvl OBJECT-TYPE
SYNTAX Integer32(1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The relevant interval number."
::= {atmLoopbackVcIvlEntry 4}
atmLoopbackVcIvlOperStatus OBJECT-TYPE
SYNTAX INTEGER {
noActive(1),
inProgress(2),
failed(3),
endSuccessfully(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"-noActive(1) means that the loopback test has not been activated for this VC during this interval.
-inProgress(2) has no meaning per interval.
-failed(3) means there was problem for this test during this interval.
-endSuccessfully(4) means that the test was OK."
::= {atmLoopbackVcIvlEntry 5}
atmLoopbackVcIvlCDV OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Cell Delay Variation for this interval."
::= {atmLoopbackVcIvlEntry 6}
atmLoopbackVcIvlAverageDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" Average delay without including lost cells."
::= {atmLoopbackVcIvlEntry 7}
atmLoopbackVcIvlMaxDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The maximum delay without including lost cells."
::= {atmLoopbackVcIvlEntry 8}
atmLoopbackVcIvlMinDelay OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The minimum delay."
::= {atmLoopbackVcIvlEntry 9}
atmLoopbackVcIvlErrSessions OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Errored Sessions. Will be updated once in 5 seconds."
::= {atmLoopbackVcIvlEntry 10}
atmNtePM OBJECT IDENTIFIER ::= {atmNtePrt 3}
atmVpPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVpPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for VP performance monitoring."
::= {atmNtePM 1 }
atmVpPmEntry OBJECT-TYPE
SYNTAX AtmVpPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmVpPmIfIndex,atmVpPmVpi}
::= {atmVpPmTable 1}
AtmVpPmEntry ::=
SEQUENCE {
atmVpPmIfIndex Integer32,
atmVpPmVpi Integer32,
atmVpPmAdminStatus INTEGER,
atmVpPmDirection INTEGER,
atmVpPmBlockSize Integer32,
atmVpPmRowStatus RowStatus,
atmVpPmSink INTEGER,
atmVpPmSource INTEGER
}
atmVpPmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmVpPmEntry 1}
atmVpPmVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the Performance Monitoring VPL."
::= {atmVpPmEntry 2}
atmVpPmAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up (2),
down(3),
listenToActivationCells (4),
originateActivationCells (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"up(2) - Activate PM.
down(3) - Deactivate PM.
listenToActivationCells(4) - .
originateActivationCells(5) - ."
::= {atmVpPmEntry 3}
atmVpPmDirection OBJECT-TYPE
SYNTAX INTEGER {
source(2),
destination(3),
bidirectional(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The direction of PM."
::= {atmVpPmEntry 4}
atmVpPmBlockSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096,
8192, 16384, 32768."
::= {atmVpPmEntry 5}
atmVpPmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= {atmVpPmEntry 6}
atmVpPmSink OBJECT-TYPE
SYNTAX INTEGER {
off (1),
fwd (2),
fwdAndBwdReport(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"off (1) - Deactivate PM.
fwd (2) - Activate Forward PM only.
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
::= {atmVpPmEntry 7}
atmVpPmSource OBJECT-TYPE
SYNTAX INTEGER {
off (1),
fwd (2),
fwdAndBwdReport(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"off (1) - Deactivate PM.
fwd (2) - Activate Forward PM only.
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
::= {atmVpPmEntry 8}
atmVcPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmVcPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains parameters for VC performance monitoring."
::= {atmNtePM 2 }
atmVcPmEntry OBJECT-TYPE
SYNTAX AtmVcPmEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmVcPmIfIndex,atmVcPmVpi,atmVcPmVci}
::= {atmVcPmTable 1}
AtmVcPmEntry ::=
SEQUENCE {
atmVcPmIfIndex Integer32,
atmVcPmVpi Integer32,
atmVcPmVci Integer32,
atmVcPmAdminStatus INTEGER,
atmVcPmDirection INTEGER,
atmVcPmBlockSize Integer32,
atmVcPmRowStatus RowStatus,
atmVcPmSink INTEGER,
atmVcPmSource INTEGER
}
atmVcPmIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface index of the ATM layer."
::= {atmVcPmEntry 1}
atmVcPmVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VPI of the Performance Monitoring VCL."
::= {atmVcPmEntry 2}
atmVcPmVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The VCI of the PM VCL."
::= {atmVcPmEntry 3}
atmVcPmAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
up (2),
down(3),
listenToActivationCells (4),
originateActivationCells (5)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"up(2) - Activate PM.
down(3) - Deactivate PM.
listenToActivationCells(4) - .
originateActivationCells(5) - ."
::= {atmVcPmEntry 4}
atmVcPmDirection OBJECT-TYPE
SYNTAX INTEGER { source(2), destination(3), bidirectional(4) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The direction of PM."
::= {atmVcPmEntry 5}
atmVcPmBlockSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Valid block sizes (in cells): 128, 256, 512, 1024, 2048, 4096,
8192, 16384, 32768."
::= {atmVcPmEntry 6}
atmVcPmRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table."
::= {atmVcPmEntry 7}
atmVcPmSink OBJECT-TYPE
SYNTAX INTEGER {
off (1),
fwd (2),
fwdAndBwdReport(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"off (1) - Deactivate PM.
fwd (2) - Activate Forward PM only.
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
::= {atmVcPmEntry 8}
atmVcPmSource OBJECT-TYPE
SYNTAX INTEGER {
off (1),
fwd (2),
fwdAndBwdReport(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"off (1) - Deactivate PM.
fwd (2) - Activate Forward PM only.
fwdAndBwdReport(3) - Activate Forward PM and Backward reporting."
::= {atmVcPmEntry 9}
atmNteMdl OBJECT IDENTIFIER ::= {atmNte 3}
atmNteMdlConfig OBJECT IDENTIFIER ::= {atmNteMdl 1}
atmNteMdlConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmNteMdlConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Module configuration table."
::= { atmNteMdlConfig 1 }
atmNteMdlConfigEntry OBJECT-TYPE
SYNTAX AtmNteMdlConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"There is an entry in this table just for those modules that have
parameters that are relevant to module level only."
INDEX {atmNteMdlSlotIndex}
::= {atmNteMdlConfigTable 1}
AtmNteMdlConfigEntry ::=
SEQUENCE {
atmNteMdlSlotIndex Integer32,
atmNteMdlPrtCpuSharing INTEGER,
atmNteMdlInputPriorityMechanism INTEGER
}
atmNteMdlSlotIndex OBJECT-TYPE
SYNTAX Integer32 (1..4)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The slot number."
::= { atmNteMdlConfigEntry 1}
atmNteMdlPrtCpuSharing OBJECT-TYPE
SYNTAX INTEGER {
equal (2),
port1 (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object lets the user decide what will be the CPU sharing
between the ports of the module. This object is applicable for
modules in which the same CPU handles the traffic of all ports.
equal - All ports will have the same CPU resource.
port1 - Port 1 will have higher priority than the other ports."
::= {atmNteMdlConfigEntry 2}
atmNteMdlInputPriorityMechanism OBJECT-TYPE
SYNTAX INTEGER {
disabled (2),
enabled (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object allows the user to Enable/Disable the Input priority mechanism.
This object is applicable for modules with more than one port, in which the
total ports input may be greater than the port output.
disabled - all LAN VCCs will be transmitted through the same queue (queue 1).
Upon congestion frames will be dropped randomly.
enabled - the user should configure each port/connection priority. Upon
congestion frames will be dropped according to priority."
::= {atmNteMdlConfigEntry 3}
atmGenSystem OBJECT IDENTIFIER ::= {atmGen 2}
--atmGenModules OBJECT IDENTIFIER ::= {atmGen 3} located in ace2002.txt
atmGenSysGen OBJECT IDENTIFIER ::= {atmGenSystem 1}
-- The self test table
atmGenSysSelfTestTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmGenSysSelfTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table containing the results of the initial testing of the device."
::= { atmGenSysGen 1 }
atmGenSysSelfTestEntry OBJECT-TYPE
SYNTAX AtmGenSysSelfTestEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmGenSysSelfTestIndex}
::= {atmGenSysSelfTestTable 1}
AtmGenSysSelfTestEntry ::=
SEQUENCE {
atmGenSysSelfTestIndex Integer32,
atmGenSysSelfTestResult DisplayString
}
atmGenSysSelfTestIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A running index for the table."
::= { atmGenSysSelfTestEntry 1}
atmGenSysSelfTestResult OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The results of the initial testing of the device."
::= { atmGenSysSelfTestEntry 2}
-- The Log clear all
atmGenSysLogClearAll OBJECT-TYPE
SYNTAX INTEGER { off(2),clear(3)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting the variable to clear(3) removes all entries in the
Log Buffer of the agent. The agent will immediately
reset the variable to off(2)."
::= { atmGenSysGen 2}
-- The Log table
atmGenSysLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmGenSysLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A copy of the log buffer."
::= { atmGenSysGen 3 }
atmGenSysLogEntry OBJECT-TYPE
SYNTAX AtmGenSysLogEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {atmGenSysLogIndex}
::= {atmGenSysLogTable 1}
AtmGenSysLogEntry ::=
SEQUENCE {
atmGenSysLogIndex Integer32,
atmGenSysLogMessage DisplayString
}
atmGenSysLogIndex OBJECT-TYPE
SYNTAX Integer32 (1..2048)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the log buffer."
::= { atmGenSysLogEntry 1}
atmGenSysLogMessage OBJECT-TYPE
SYNTAX DisplayString (SIZE(80))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The log buffer entry message text."
::= { atmGenSysLogEntry 2}
-- Set to default configuration
atmGenSysSetDefaultConfg OBJECT-TYPE
SYNTAX INTEGER { off(2), on(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When set to on(3), the agent will set all the configuration parameters
to their default values. The variable is then reset to off(2)
by the agent. The agent must be reset for the default configuration
to apply."
::= {atmGenSysGen 4}
-- A Cross Reference table for connections between tables.
atmGenSysCxRefTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmGenSysCxRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Cross Reference table. The table maintains
an index of an object which is also the table index,
and a counter that indicates how many times this
object was referenced.
When using this table for more than one referenced table,
which uses the same range of indexes, then the index
should be shifted by a unique offset per table.
In ACE2002 this table is used for TD and for FR Desc. Thus,
the index for FR Descriptor is: FR Descriptor index + offset.
The offset is described in the ACE2002 NMS SRS."
::= {atmGenSysGen 5}
atmGenSysCxRefEntry OBJECT-TYPE
SYNTAX AtmGenSysCxRefEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries will be added by the agent upon
an entry addition in the referenced tables
(TD table, FR Descriptor etc.)"
INDEX { atmGenSysCxRefIndex }
::= { atmGenSysCxRefTable 1 }
AtmGenSysCxRefEntry ::=
SEQUENCE {
atmGenSysCxRefIndex
Integer32,
atmGenSysCxRefCounter
Gauge32
}
atmGenSysCxRefIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index specifies an entry in the table of the object."
::= { atmGenSysCxRefEntry 1 }
atmGenSysCxRefCounter OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter counts the number of references
that have been made to the object ."
::= { atmGenSysCxRefEntry 2 }
-- Traps
-- System Layer Traps
atmAceStatusChange NOTIFICATION-TYPE
OBJECTS {agnLed,agnIndication}
STATUS current
DESCRIPTION
"The trap is sent every time there is a change in
the state of one of the LEDs."
::= { atmNteEvents 1 }
atmAceAlarmTrap NOTIFICATION-TYPE
OBJECTS {atmInterfaceAlarmStatus}
STATUS current
DESCRIPTION
"The trap is sent whenever there is a transition from a no alarm
state to a state with at least one active alarm. An active alarm
state exists if:
1) The atmInterfaceActiveAlarms vector is different than 0.
2) The atmNteAlarmVpTable contains entries.
3) The atmNteAlarmVcTable contains entries.
The trap is also sent when a transition into the no alarm state
occurs.
The second variable will be atmInterfaceActiveAlarms to
indicate the kind of the alarm.
The trap is not sent more than once in a 10 second interval."
::= { atmNteEvents 2 }
atmAceModuleChangeTrap NOTIFICATION-TYPE
OBJECTS {ifIndex}
STATUS current
DESCRIPTION
"The trap is sent every time a module is changed (Hot swapping).
The second variable will be atmNteCardType to indicate the
type of card that was inserted. The value empty(255) indicates that
a card was taken out."
::= { atmNteEvents 3 }
atmAceRedundancyTrap NOTIFICATION-TYPE
OBJECTS {ifIndex }
STATUS current
DESCRIPTION
"The trap is sent upon change in link as a result of redundancy.
The ifIndex parameter indicates the current active link."
::= { atmNteEvents 4 }
atmAceModuleMismatchTrap NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"The trap is sent upon starting or stopping of
a module mismatch state.
A possible mismatch is when the inserted module is other
than the programmed one."
::= { atmNteEvents 5 }
atmAceSystemTrap NOTIFICATION-TYPE
OBJECTS { atmNteEventType, agnLed, alarmSeverity }
STATUS current
DESCRIPTION
"This trap alerts of major problems in the device."
::= { radSysAtmEvents 6 }
atmAceAlarmForwardingTrap NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState }
STATUS current
DESCRIPTION
"This trap is sent upon starting or stopping Alarm
Forwarding Mechanism."
::= { radSysAtmEvents 7 }
atmAceDateAndTimeRequest NOTIFICATION-TYPE
-- OBJECTS { sysObjectID }
STATUS current
DESCRIPTION
"This trap is sent upon restart. It will send sysObjectID variable.
Upon recieving this trap the NMS will set the device's date and time.
This trap's purpose is to fix a problem in ACE2002, ACE-2002E, ACE-202.
The problem is that the Date and Time is stored in the NVRAM,
and when the NVRAM's battery is empty, the device loses this information."
::= { radSysAtmEvents 8 }
-- Alarms Traps
atmAceAlarmLOS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss Of Signal."
::= { radSysAtmEvents 16 }
atmAceAlarmLOF NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss Of Frame."
::= { radSysAtmEvents 17 }
atmAceAlarmLCD NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss of Cell Delineation."
::= { radSysAtmEvents 18 }
atmAceAlarmSLM NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Signal Line Mismatch."
::= { radSysAtmEvents 19 }
atmAceAlarmLOP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss of Pointer."
::= { radSysAtmEvents 20 }
atmAceAlarmLineAIS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Line AIS."
::= { radSysAtmEvents 21 }
atmAceAlarmPathAIS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Path AIS."
::= { radSysAtmEvents 22 }
atmAceAlarmLineRDI NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Line RDI."
::= { radSysAtmEvents 23 }
atmAceAlarmPathRDI NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Path RDIand Path RAI(Yellow) for
DS1 interfaces."
::= { radSysAtmEvents 24 }
atmAceAlarmSectionBIP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Section Bit Interleave Parity."
::= { radSysAtmEvents 25 }
atmAceAlarmLineBIP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Line Bit Interleave Parity."
::= { radSysAtmEvents 26 }
atmAceAlarmPathBIP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Path Bit Interleave Parity."
::= { radSysAtmEvents 27 }
atmAceAlarmLineFEBE NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Line Far End Block Error."
::= { radSysAtmEvents 28 }
atmAceAlarmPathFEBE NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Path Far End Block Error."
::= { radSysAtmEvents 29 }
atmAceAlarmPlcpLOF NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 PLCP Loss Of Frame."
::= { radSysAtmEvents 30 }
atmAceAlarmPlcpYELLOW NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 Plcp Yellow."
::= { radSysAtmEvents 31 }
atmAceAlarmPlcpBIP NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 Plcp Bit Interleave Parity."
::= { radSysAtmEvents 32 }
atmAceAlarmPlcpFEBE NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 Plcp Far End Block Error."
::= { radSysAtmEvents 33 }
atmAceAlarmPlcpP1P2 NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates T3 Plcp Parity errors in P1/P2 bytes."
::= { radSysAtmEvents 34 }
atmAceAlarmUAS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon UAS start or end per port."
::= { radSysAtmEvents 35 }
atmAceAlarmCluster NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, atmNteAlarmType, atmNteLevel }
STATUS current
DESCRIPTION
"This trap is sent upon atmNteAlarmType start or end,
for a cluster of VPs/VCs (according to atmNteLevel) with
the same alarm on the same physical port.
This trap replaces sending the same alarm for a big
quantity (the quantity described in the product
specification document) of VPs/VCs in order to prevent
flooding the NMS and the network with traps."
::= { radSysAtmEvents 36 }
atmAceHwFailure NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon HW failure per port."
::= { radSysAtmEvents 37 }
atmAceUnavailableBwTrap NOTIFICATION-TYPE
OBJECTS { alarmSeverity, ifAlias, atmConfIfInputRate, atmConfIfOutputRate }
STATUS current
DESCRIPTION
"This trap is sent when Bandwidth allocation is > max possible
value for the installed card.
For ACE2002 this trap will be sent for the following cases:
Card insertion - if the total Input and/or Output Bandwidth is over
allocated, then the specific card rate will be set to 0 and this trap
will be sent with the Input/Output rates values.
Upgrade from former version - when an over allocated Bandwidth is detected,
this trap will be sent with atmConfIfInputRate=atmConfIfOutputRate=0xFFFFFFFF."
::= { radSysAtmEvents 38 }
--
-- OAM LOOPBACK
-- atmAceOAMLoopBackCellRx NOTIFICATION-TYPE
-- OBJECTS { alarmSeverity, alarmState,ifAlias }
-- STATUS current
-- DESCRIPTION
-- "This Trap indicates that a loopback has
-- been activated on device ATM uplink interface
-- by the remote ATM equipment, by means of OAM cells"
-- ::= { radSysAtmEvents 39 }
--
--
-- OAM LOOPBACK
-- atmAceOAMLoopBackCellTx NOTIFICATION-TYPE
-- OBJECTS { alarmSeverity, alarmState,ifAlias }
-- STATUS current
-- DESCRIPTION
-- "This Trap indicates that a loopback has
-- been initiated by local device on ATM uplink interface
-- towards remote ATM equipment, by sending OAM cells."
-- ::= { radSysAtmEvents 15 }
-- VP Layer Traps
-- atmVplVpi have MAX-ACCESS "not-accessible"
-- and cannot be referenced from NOTIFICATION-TYPE clause
-- in SMIV2 so they where removed from following caluses.
-- Dovi Korngut (28/6/00).
atmAceAlarmVpContinuityLoss NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss of Continuity Check on a VP Connection."
::= { radSysAtmEvents 40 }
atmAceAlarmVpAISReception NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates AIS Reception on a VP Connection."
::= { radSysAtmEvents 41 }
atmAceAlarmVpRDIReception NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates RDI Reception on a VP Connection."
::= { radSysAtmEvents 42 }
atmAceAlarmVpErroredCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Errored Cells on a VP Connection reported by PM."
::= { radSysAtmEvents 43 }
atmAceAlarmVpLostCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Lost Cells on a VP Connection reported by PM."
::= { radSysAtmEvents 44 }
atmAceAlarmVpMisinsertedCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Misinserted Cells on a VP Connection
reported by PM."
::= { radSysAtmEvents 45 }
atmAceAlarmVpUAS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon UAS start or end per VP."
::= { radSysAtmEvents 46 }
atmAceAlarmVpLoopback NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon OAM LoopBack fail status per VP."
::= { radSysAtmEvents 47 }
atmAceAlarmVpGCRAViolation NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates GCRA violation on a VP Connection
reported by UPC device."
::= { radSysAtmEvents 48 }
-- VC Layer Traps
-- atmVclVpi and atmVclVci have MAX-ACCESS "not-accessible"
-- and cannot be referenced from NOTIFICATION-TYPE clause
-- in SMIV2 so they where removed from following caluses.
-- Dovi Korngut (28/6/00).
atmAceAlarmVcContinuityLoss NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Loss of Continuity Check on a VC Connection."
::= { radSysAtmEvents 56 }
atmAceAlarmVcAISReception NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates AIS Reception on a VC."
::= { radSysAtmEvents 57 }
atmAceAlarmVcRDIReception NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates RDI Reception on a VC Connection."
::= { radSysAtmEvents 58 }
atmAceAlarmVcErroredCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Errored Cells on a VC Connection reported by PM."
::= { radSysAtmEvents 59 }
atmAceAlarmVcLostCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Lost Cells on a VC Connection reported by PM."
::= { radSysAtmEvents 60 }
atmAceAlarmVcMisinsertedCells NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates Misinserted Cells on a VC Connection reported
by PM."
::= { radSysAtmEvents 61 }
atmAceAlarmVcUnexpectedCell NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates an unexpected cell from user or network port."
::= { radSysAtmEvents 62 }
atmAceAlarmVcUAS NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon UAS start or end per VC."
::= { radSysAtmEvents 63 }
atmAceAlarmVcLoopback NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap is sent upon OAM LoopBack fail status per VC."
::= { radSysAtmEvents 64 }
atmAceAlarmVcGCRAViolation NOTIFICATION-TYPE
OBJECTS { alarmSeverity, alarmState, ifAlias }
STATUS current
DESCRIPTION
"This trap indicates GCRA violation on a VC Connection
reported by UPC device."
::= { radSysAtmEvents 65 }
-- number 80 and up are saved for IMA traps
-- END
-- SENDING OAM VC-AIS CELLS ??
-- This message appears when the LA-110 starts/stop
-- transmitting OAM cells of type VC-AIS to the
-- ATM network the alarm description
-- will be followed with the relevant VP/VC
--
-- SENDING OAM VC-RDI CELLS ???
-- This message appears when the LA-110 start/stop
-- transmitting OAM cells of type VC-RDI to the
-- ATM network the alarm description will be
-- followed with the relevant VP/VC
--
--
-- file :v:\doc\rdv\mib\ver485\ipRouter.txt
--
--Version: 1.0
--Date: 31.01.99
--By: Ilana Schvetz
--File: ipRouter.txt
--
--Last Update: Ilana Schvetz 09/01/02
--radRouter OBJECT IDENTIFIER ::= { rad 11 }
--rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
ipRouter OBJECT IDENTIFIER ::= { rtrBridge 3 }
rtrIfIpTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIfIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Router interfaces table."
::= { ipRouter 1 }
rtrIfIpEntry OBJECT-TYPE
SYNTAX RtrIfIpEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table rtrIfIpTable."
INDEX { rtrIfIp }
::= { rtrIfIpTable 1 }
RtrIfIpEntry ::=
SEQUENCE {
rtrIfIp IpAddress,
rtrIfRowStatus RowStatus,
rtrIfIpMask IpAddress,
rtrIfIndex Integer32,
rtrIfMng INTEGER,
rtrIfVlanId VlanIndex
}
rtrIfIp OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP Address."
::= { rtrIfIpEntry 1 }
rtrIfRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"."
::= { rtrIfIpEntry 2 }
rtrIfIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP mask Address."
::= { rtrIfIpEntry 3 }
rtrIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The ifIndex connection, on which the IP is determined."
::= { rtrIfIpEntry 4 }
rtrIfMng OBJECT-TYPE
SYNTAX INTEGER {
no (1),
yes (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"An IP interface might be determined as a management
connection (under the product limitations)."
::= { rtrIfIpEntry 5 }
rtrIfVlanId OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VLAN ID assigned to Tagged frames transmitted
from this port.
The value inserted should be a defined VLAN."
::= { rtrIfIpEntry 6 }
-- Brouter Table
brtrIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrtrIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LAN interface table."
::= { ipRouter 2 }
brtrIfEntry OBJECT-TYPE
SYNTAX BrtrIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries of this table will be created by agent."
INDEX { brtrIfIndex }
::= { brtrIfTable 1 }
BrtrIfEntry ::=
SEQUENCE {
brtrIfIndex Integer32,
brtrIfMode INTEGER,
brtrIfMaxFrameSize Integer32
}
brtrIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the interface (LAN or ATM)."
::= { brtrIfEntry 1 }
brtrIfMode OBJECT-TYPE
SYNTAX INTEGER {
bridge (1),
router (2),
brouter (3),
off (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Connection Mode."
::= { brtrIfEntry 2 }
brtrIfMaxFrameSize OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Frame Max Size."
::= { brtrIfEntry 3 }
rtrArpAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ARP Aging Time. Applicable for a Router Mode
and for a Brouter Mode."
::= { ipRouter 3 }
-- Brouter LAN If table
brtrLanIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF BrtrLanIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"LAN interface table."
::= { ipRouter 4 }
brtrLanIfEntry OBJECT-TYPE
SYNTAX BrtrLanIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The entries of this table will be created by agent ."
INDEX { brtrLanIfIndex }
::= { brtrLanIfTable 1 }
BrtrLanIfEntry ::=
SEQUENCE {
brtrLanIfIndex Integer32,
brtrLanIpAddress IpAddress,
brtrLanIpMask IpAddress,
brtrLanMaxRateEnable INTEGER,
brtrLanMaxRate Integer32,
brtrLanMng INTEGER,
brtrLanDefaultRouter IpAddress
}
brtrLanIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the LAN entity (physical interface)."
::= { brtrLanIfEntry 1 }
brtrLanIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Host IP address. Applicable for bridge mode connection only."
::= { brtrLanIfEntry 2 }
brtrLanIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Host IP Mask. Applicable for bridge mode connection only."
::= { brtrLanIfEntry 3 }
brtrLanMaxRateEnable OBJECT-TYPE
SYNTAX INTEGER {
disable (1),
enable (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter determines the HW ability of the LAN
card according to HW."
::= { brtrLanIfEntry 4 }
brtrLanMaxRate OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Max Rate."
::= { brtrLanIfEntry 5 }
brtrLanMng OBJECT-TYPE
SYNTAX INTEGER {
no (1),
yes (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An IP interface might be determined as a management
connection (under the product limitations)."
::= { brtrLanIfEntry 6 }
brtrLanDefaultRouter OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Default Router's (Gateway's) IP Address.
For each LAN interface there may be a different Default Router."
::= { brtrLanIfEntry 7 }
rtrIsdnIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIsdnIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ISDN parameters that do not appear in the standard MIBs."
::= { ipRouter 5 }
rtrIsdnIfEntry OBJECT-TYPE
SYNTAX RtrIsdnIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Entries for ISDN parameters that do not appear in the standard MIBs."
AUGMENTS { isdnSignalingEntry }
-- INDEX { isdnSignalingIndex }
::= { rtrIsdnIfTable 1 }
RtrIsdnIfEntry ::=
SEQUENCE {
rtrIsdnIfMinNumBchans Integer32,
rtrIsdnIfMaxNumBchans Integer32
}
rtrIsdnIfMinNumBchans OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Minimum number of B channels that the ISDN Dialer of the router will use
for Dialing out.
This parameter will be used for the BOD (Bandwidth On Demand) feature.
Dial up on B channels is according to the need of bandwidth for router
data transfer. Voice calls have a higher priority than router data.
In case of few time slots the voice calls will cause disconnection of
data channels up to the limit of minimum number of B channels."
::= { rtrIsdnIfEntry 1 }
rtrIsdnIfMaxNumBchans OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Maximum number of B channels that the ISDN Dialer of the router will use
for Dialing out.
This parameter will be used for the BOD (Bandwidth On Demand) feature.
Dial up on B channels is according to the need of bandwidth for router
data transfer. Voice calls have a higher priority than router data.
No more than MAX B channels will be used by the ISDN dialer."
::= {rtrIsdnIfEntry 2 }
rtrLcrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrLcrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Least Cost Routing Table.
The user will be able to set a prefix for an outgoing number
that arrives with a predefined prefix in order to redirect
the number for the LCR process to be achieved."
::= { ipRouter 6 }
rtrLcrEntry OBJECT-TYPE
SYNTAX RtrLcrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Least Cost Routing Entry."
INDEX { ifIndex, rtrLcrOutIfIndex }
::= { rtrLcrTable 1 }
RtrLcrEntry ::=
SEQUENCE {
rtrLcrOutIfIndex InterfaceIndex,
rtrLcrRowStatus RowStatus,
rtrLcrInPrefix DisplayString,
rtrLcrOutPrefix DisplayString
}
rtrLcrOutIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The outgoing interface Number of the current route.
The incoming interface number is the value of ifIndex."
::= { rtrLcrEntry 1 }
rtrLcrRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Row Status for adding/destroying rows."
::= { rtrLcrEntry 2 }
rtrLcrInPrefix OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This prefix is part of the called number existing in the incoming packet."
::= {rtrLcrEntry 3 }
rtrLcrOutPrefix OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This prefix will be inserted into the outgoing packet."
::= {rtrLcrEntry 4 }
--radRouter OBJECT IDENTIFIER ::= { rad 11 }
multicastGen OBJECT IDENTIFIER ::= { radRouter 8 } -- General Multicast Parameters
multicastMode OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
wanToLan (3),
wanToLanIgmp (4),
lanToWan (5),
bidirectional(6),
transparent(7)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"According to this mode the packets will be forwarded.
If disable (2) is selected, there will be no multicast."
::= { multicastGen 1 }
--
-- file :v:\doc\rdv\mib\ver485\clksrc.txt
--
-- file : clksrc.txt
--
-- available for ACE2002. This file is part of dxc.txt.
--Version: 1.0
--Date: 9.7.00
--By: Ilana Schvetz
--File: v:\doc\rdv\mib\ver485\clksrc.txt
--Last Update: 25.11.01 by Ilana
-- Copyright 1997 RAD Data Communications, Ltd.
-- All Rights Reserved.
dacsMux OBJECT IDENTIFIER ::= {radWan 3}
systemDacsMux OBJECT IDENTIFIER ::= {dacsMux 1}
sysStatus OBJECT IDENTIFIER ::= {systemDacsMux 3}
sysConfig OBJECT IDENTIFIER ::= {systemDacsMux 6}
sysSClkSrc OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback(2),
internal(3),
ml (4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This entry indicates the source of the system clock."
::= { sysStatus 7 }
--System Configuration Parameters
sysCClkSrcTable OBJECT-TYPE
SYNTAX SEQUENCE OF SysCClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"All the entries of this table are identical (have the
same value) for all the configurations (1..255) except
the TmpCnfg.
The write operation into the Table Objects is valid only
for the TmpCnfg entry."
::= { sysConfig 1}
sysCClkSrcEntry OBJECT-TYPE
SYNTAX SysCClkSrcEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {sysCClkCnfgIdx, sysCClkSrcIdx}
::= { sysCClkSrcTable 1}
SysCClkSrcEntry ::=
SEQUENCE {
sysCClkCnfgIdx Integer32,
sysCClkSrcIdx INTEGER,
sysCClkSrcMode INTEGER,
sysCClkSrcPrt Integer32,
sysCClkStationFreq INTEGER,
sysCClkRevertiveTimeout Integer32
}
sysCClkCnfgIdx OBJECT-TYPE
SYNTAX Integer32 (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This attribute indicates the Idx of the Cnfg(1..255) being
accessed ; Idx of 255 relates to the TmpCnfg."
::= { sysCClkSrcEntry 1}
-- In phase I of DXC and FCD, only the values 1 (Cnfg1) and 255
-- (temp) are valid.
sysCClkSrcIdx OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
fallback (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"An index in the table. There are only two entries in the
table.
master - refers Master clock parameters
fallback - refers Fallback clock parameters"
::= { sysCClkSrcEntry 2}
sysCClkSrcMode OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
internal (2),
rxClk (3),
station (4),
lbt (5),
ntr (6),
adaptive (7),
notApplicable (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the source the nodal timing is
locked to.
none - is an invalid option for Master clock.
internal - is an invalid option for Fallback clock .
station - is an invalid option for a stand-alone unit.
lbt - loop-back timing
ntr - A system locked reference clock
adaptive - clcok locking is achieved by altering the clock
according to the data load
notApplicable - for ML source of Kmux or ML Timing
combinations when Master/Fallback clock are
not applicable."
::= { sysCClkSrcEntry 3}
sysCClkSrcPrt OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry is valid only when working in rxClk mode.
For ACE2002 in case of invalid entry the return value
will be 0.
For other products in case of invalid entry the return
value will be 9999.
The valid port number depends on the IO slot no., the
installed card type and the port type: outside, inside,
SP.
* The SP ports will be numbered as follows:
- SP port 1 : 1
- SP port 2 : 2
For external ports the convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in odd numbers:
port1 = 1
port2 = 3
port3 = 5
etc...
Example: port2 of IO slot 11 will be: 213 .
For internal ports the convention used will be (for DXC):
- first two digits will be: (IO slot number+10)
- last one/two digits will be the port number within the
card, in even numbers:
port1 = 2
port2 = 4
port3 = 6
etc...
Example: port2 of IO slot 11 will be: 214 .
For Kmux, the port will be according to : Slot*100+Ch.
For ACE2002 and LA140, the port will be ifIndex."
::= { sysCClkSrcEntry 4}
sysCClkStationFreq OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
f1544Khz (2),
f2048Khz (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This entry indicates the frequency of the station clock
when the source is 'station'.
The value will be applicable only when the sysCClkSrcMode is
'station'. "
::= { sysCClkSrcEntry 5}
sysCClkRevertiveTimeout OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time in seconds in which the system will monitor the higher
level clock source, before decision to revert to that clock.
In case the time is zero, revertive mode will be disabled."
::= { sysCClkSrcEntry 6}
--
-- file :v:\doc\rdv\mib\ver495\sub_rtr.txt
--
-- version 4.95
-- file :sub_rtr.txt
--
--RTR-MIB
--
--Last update: 30-Apr-2003 by Shay Harari
--radRouter OBJECT IDENTIFIER ::= { rad 11 } RAD Router
-- ************************************************
-- Interfaces Group
-- Link Layer (layer 2) Configuration MIB
-- ************************************************
-- The following MIB group is used by the Management/Configuration
-- station to configure the device interfaces,
-- physicals as well as virtuals.
-- Each entry in the rtrDynamicIfConfigTable should have one of
-- the extended rtType.
-- It will also have a corresponding entry in the standard iftable.
-- The implementation uses these inputs to build the interface
-- layer of the device. The output is reflected in the
-- ifTable and ifStackTable which are implementation dependent.
rtrInterfaces OBJECT IDENTIFIER ::= { radRouter 1 }
RtrIfConfigTYPE ::= INTEGER
-- STATUS current
-- DESCRIPTION
-- "This type defines what type of sub-layer is used
-- in each entr of rtrDynamicIfConfigTable.
-- It should contain values from IANAifType
-- type for standard sub-layer, and values (starting from 999
-- decimal) for private sub-layers.
-- The values of the ifType field in ifTable should be taken
-- from IANAifType only."
{
other(1),
ethernetLan(6), -- From IANAifType
iso88023Csmacd(7),
tokenRingLan(9),
fddi(15),
basicISDN(20),
primaryISDN(21),
propPointToPoint(22), -- rndWAN
slip(28),
ppp(23), -- From IANAifType
frameRelay(32),
rs232(33),
atm(37),
x25ple(40),
v35(45),
fastEther(62), -- Fast Ethernet (100BaseT)
fastEtherFX(69), -- Fast Ethernet (100BaseFX)
virtualNet(500),
cod(1001), -- Rad/Rnd private
backUp(1002),
dialUp(1004),
b1isdn(1010),
b2isdn(1011),
ipBcst(1020),
ipPtp(1021),
ipxRaw(1022),
ipxEtType(1023),
ipxLlcSap(1024),
ipxLlcSnap(1025),
ipxPtp(1026),
brgUnder(1027),
wanDriver(1060),
ethernetDriver(1061),
tokenRingDriver(1062),
fddiDriver (1064), -- RAD private FDDI driver
virtualLan(1080),
unknown(1100)
}
rtrConfigIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrConfigIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of configured interfaces."
::= { rtrInterfaces 1 }
rtrConfigIfEntry OBJECT-TYPE
SYNTAX RtrConfigIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry defines a configured interface."
INDEX { rtrConfigIfIndex }
::= { rtrConfigIfTable 1 }
RtrConfigIfEntry ::= SEQUENCE {
rtrConfigIfIndex
InterfaceIndex,
rtrConfigIfType
RtrIfConfigTYPE,
rtrConfigIfName
DisplayString,
rtrConfigIfStatus
RowStatus
}
rtrConfigIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable uniquely identifies the interface.
It is used as a cross reference in other system tables"
::= { rtrConfigIfEntry 1 }
rtrConfigIfType OBJECT-TYPE
SYNTAX RtrIfConfigTYPE
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable identifies the type of the specific
entry in the rtrDynamicIfConfigTable.
This field is writable only at creation time
(i.e., when value of status is underCreation)."
::= { rtrConfigIfEntry 2 }
rtrConfigIfName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This variable provides a logical name to a specific entry in
rtrConfigIfTable. It is also used in identifying the Driver
interfaces."
::= { rtrConfigIfEntry 3 }
rtrConfigIfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the ConfigEntry. The choices are those
defined in SNMPv2-TC. Only: active, createAndWait, and destroy
will be used.
active - The conceptual row is available for use by the managed device.
createAndWait - A new instance of a conceptual row is desired, but
not to have it available for use by the managed device.
destroy - Delete all instances associated with an existing conceptual row."
::= { rtrConfigIfEntry 4 }
-- Router Interface Configuration Table
rtrIfCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIfCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Router Interface Configuration Table."
::= { rtrInterfaces 2 }
rtrIfCfgEntry OBJECT-TYPE
SYNTAX RtrIfCfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Router Interface Configuration Table."
INDEX { rtrIfCfgIndex, rtrIfCfgIpAddress }
::= { rtrIfCfgTable 1 }
RtrIfCfgEntry ::= SEQUENCE {
rtrIfCfgIndex
Integer32,
rtrIfCfgIpAddress
IpAddress,
rtrIfCfgRowStatus
RowStatus,
rtrIfCfgIpMask
IpAddress,
rtrIfCfgIfIndex
Integer32,
rtrIfCfgType
INTEGER,
rtrIfCfgVlanId
VlanIndex
}
rtrIfCfgIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Router Interface Index.
(In some cases it will be equal to the Router Interface ifIndex)."
::= { rtrIfCfgEntry 1 }
rtrIfCfgIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP Address of the Router Interface."
::= { rtrIfCfgEntry 2 }
rtrIfCfgRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries of this table."
::= { rtrIfCfgEntry 3 }
rtrIfCfgIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"IP Mask Address Router Interface."
::= { rtrIfCfgEntry 4 }
rtrIfCfgIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ifIndex of the device interface connected
to this Router Interface."
::= { rtrIfCfgEntry 5 }
rtrIfCfgType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
atm (2),
lis (3),
ethernet(4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The Router Interface Type.
atm - ATM router interface
lis - Logical IP Subnet router interface.
ethernet - Ethernet router interface. "
::= { rtrIfCfgEntry 6 }
rtrIfCfgVlanId OBJECT-TYPE
SYNTAX VlanIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The VLAN ID assigned to Tagged frames transmitted
from this Router Interface.
The value inserted should be a defined VLAN."
::= { rtrIfCfgEntry 7 }
-- **************** Interfaces Groups End *******************
-- **************** IP Groups ******************
-- IP Group
-- ************************************************
-- IP Interface Configuration MIB
-- ************************************************
ipSpec OBJECT IDENTIFIER ::= { radRouter 2 }
rtrIpAddrTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIpAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is parralel to MIB II IpAddrTable, and is used to
add/delete entries to/from that table. In addition it contains
private objects."
::= { ipSpec 1 }
rtrIpAddrEntry OBJECT-TYPE
SYNTAX RtrIpAddrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The addressing information for one of this
entity's IP addresses."
INDEX {rtrIpAdEntAddr}
::= { rtrIpAddrTable 1 }
RtrIpAddrEntry ::= SEQUENCE {
rtrIpAdEntAddr IpAddress,
rtrIpAdEntIfIndex Integer32,
rtrIpAdEntNetMask IpAddress,
rtrIpAdEntForwardIpBroadcast INTEGER,
rtrIpAdEntBackupAddr IpAddress,
rtrIpAdEntStatus RowStatus
}
rtrIpAdEntAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address to which this entry's addressing
information pertains."
::= { rtrIpAddrEntry 1 }
rtrIpAdEntIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The index value which uniquely identifies the
interface to which this entry is applicable. The
interface identified by a particular value of this
index is the same interface as identified by the
same value of ifIndex."
::= { rtrIpAddrEntry 2 }
rtrIpAdEntNetMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The subnet mask associated with the IP address of
this entry. The value of the mask is an IP
address with all the network bits set to 1 and all
the hosts bits set to 0."
::= { rtrIpAddrEntry 3 }
rtrIpAdEntForwardIpBroadcast OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" This variable controls forwarding of IP (sub)net-directed
broadcasts destined for an attached sub(net). "
DEFVAL { enable }
::= { rtrIpAddrEntry 4 }
rtrIpAdEntBackupAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" "
::= { rtrIpAddrEntry 5 }
rtrIpAdEntStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" The Status variable is used to create and destroy a Ip Addresses."
::= { rtrIpAddrEntry 6 }
icmpSpec OBJECT IDENTIFIER ::= { ipSpec 2 }
rtrIcmpGenErrMsgEnable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable controlls the ability to generate ICMP error messages"
DEFVAL { enable }
::= { icmpSpec 1 }
rtrIcmpRdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrIcmpRdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains ICMP Router Discovery parameters
configurated per IP interface."
::= {icmpSpec 2}
rtrIcmpRdEntry OBJECT-TYPE
SYNTAX RtrIcmpRdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The ICMP parameters configurated for IP interface."
INDEX {rtrIcmpRdIpAddr}
::= {rtrIcmpRdTable 1}
RtrIcmpRdEntry ::= SEQUENCE {
rtrIcmpRdIpAddr IpAddress,
rtrIcmpRdIpAdvertAddr IpAddress,
rtrIcmpRdMaxAdvertInterval Integer32,
rtrIcmpRdMinAdvertInterval Integer32,
rtrIcmpRdAdvertLifetime Integer32,
rtrIcmpRdAdvertise INTEGER,
rtrIcmpRdPreferenceLevel Integer32,
rtrIcmpRdEntStatus Integer32
}
rtrIcmpRdIpAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP address to which this entry's information pertains."
::= {rtrIcmpRdEntry 1}
rtrIcmpRdIpAdvertAddr OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" The IP destination address to be used for multicast
Router Advertisements sent from the interface. The
only permissible values are the all-systems multicast
address, 224.0.0.1, or the limited-broadcast address,
255.255.255.255."
-- DEFVAL {224.0.0.1}
::= {rtrIcmpRdEntry 2}
rtrIcmpRdMaxAdvertInterval OBJECT-TYPE
SYNTAX Integer32 (4..1800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum time allowed between sending multicast
Router Advertisements from the interface, in seconds.
Must be no less than 4 seconds and no greater than 1800
seconds."
DEFVAL {600}
::= {rtrIcmpRdEntry 3}
rtrIcmpRdMinAdvertInterval OBJECT-TYPE
SYNTAX Integer32 (3..1800)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The minimum time allowed between sending unsolicited
multicast Router Advertisements from the interface, in
seconds. Must be no less than 3 seconds and no greater
than rtrIcmpRdMaxAdvertInterval.
Default: 0.75 * rtrIcmpRdMaxAdvertInterval."
::= {rtrIcmpRdEntry 4}
rtrIcmpRdAdvertLifetime OBJECT-TYPE
SYNTAX Integer32 (4..9000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The maximum length of time that the advertised addresses
are to be considered as valid. Must be no less than
rtrIcmpRdMaxAdvertInterval and no greater than 9000 seconds.
Default: 3 * rtrIcmpRdMaxAdvertInterval."
::= {rtrIcmpRdEntry 5}
rtrIcmpRdAdvertise OBJECT-TYPE
SYNTAX INTEGER {
enable (1),
disable (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"A flag indicating whether or not the address is to be
advertised."
DEFVAL {enable}
::= {rtrIcmpRdEntry 6}
rtrIcmpRdPreferenceLevel OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The preferability of the address as a default router
address, relative to other router addresses on the same
subnet."
DEFVAL {0}
::= {rtrIcmpRdEntry 7}
rtrIcmpRdEntStatus OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting of any value to this object set values of
all fields to the default values."
::= {rtrIcmpRdEntry 8}
rip2Spec OBJECT IDENTIFIER ::= { ipSpec 3 }
rtrRip2IfConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrRip2IfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of rip2IfConfTable (RFC 1724 ,RIP 2).
It means that every time somebody creates/destroys a row in the
rip2IfConfTable, the same row should be automatically created/destroyed
in this table."
::= { rip2Spec 1 }
rtrRip2IfConfEntry OBJECT-TYPE
SYNTAX RtrRip2IfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in table rtrRip2IfConfTable."
INDEX { rtrRip2IfConfAddress }
::= { rtrRip2IfConfTable 1 }
RtrRip2IfConfEntry ::= SEQUENCE {
rtrRip2IfConfAddress IpAddress,
rtrRip2IfConfVirtualDis Integer32,
rtrRip2IfConfAutoSend INTEGER
}
rtrRip2IfConfAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The IP Address of this system on the indicated subnet. "
::= { rtrRip2IfConfEntry 1 }
rtrRip2IfConfVirtualDis OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"This variable defines the virtual number of hops assigned to
the interface specified by rtrIfIpAddrIndex. This enables
fine-tuning of the RIP routing algorithm."
DEFVAL { 1 }
::= { rtrRip2IfConfEntry 2 }
rtrRip2IfConfAutoSend OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS deprecated
DESCRIPTION
"When set to enable only the default route is sent through
the interface. When set to disable, regular RIPs are sent."
DEFVAL { disable }
::= { rtrRip2IfConfEntry 3 }
arpSpec OBJECT IDENTIFIER ::= { ipSpec 4 }
rtrArpDeleteTable OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Setting this object to any not-null value has the effect of deleting
all entries of the ARP table."
::= { arpSpec 1 }
rtrArpInactiveTimeOut OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable defines the maximum time period (in second) that can
pass between ARP requests concerning an entry in the ARP table.
After this time period, the entry is deleted from the table."
DEFVAL { 60000 }
::= { arpSpec 2 }
rtrArpProxy OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"When ARP Proxy is enabled, the router can respond to
ARP requests for nodes located on a different sub-net,
provided they are it its network table. The router responds
with its own MAC address.
When ARP Proxy is disabled, the router responds only
to ARP requests for its own IP addresses."
DEFVAL { disable }
::= { arpSpec 3 }
-- ****************************************
-- NAT Network Address Translation
-- *****************************************
rtrNat OBJECT IDENTIFIER ::= { ipSpec 5 }
rtrNatIfConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrNatIfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of interfaces which require separate NAT configuration."
::= {rtrNat 1}
rtrNatIfConfEntry OBJECT-TYPE
SYNTAX RtrNatIfConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A single routing domain in a single subnet."
INDEX { ifIndex, rtrNatIfVirtualAddress, rtrNatIfVirtualMask }
::= { rtrNatIfConfTable 1 }
RtrNatIfConfEntry ::=
SEQUENCE {
rtrNatIfVirtualAddress IpAddress,
rtrNatIfVirtualMask IpAddress,
rtrNatIfConfStatus RowStatus,
rtrNatIfRealAddress IpAddress,
rtrNatIfRealMask IpAddress,
rtrNatIfType INTEGER
}
rtrNatIfVirtualAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IP Address of the virtual subnet to be translated by the 'NAT box'
attached to this interface."
::= { rtrNatIfConfEntry 1 }
rtrNatIfVirtualMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The subnet Mask of the virtual subnet. "
::= { rtrNatIfConfEntry 2 }
rtrNatIfConfStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Writing 'destroy' has the effect of deleting this interface."
::= { rtrNatIfConfEntry 3 }
rtrNatIfRealAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" The IP Address of the real subnet which is used by 'NAT box' for translation."
::= { rtrNatIfConfEntry 4 }
rtrNatIfRealMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
" The subnet Mask of the real subnet."
::= { rtrNatIfConfEntry 5 }
rtrNatIfType OBJECT-TYPE
SYNTAX INTEGER {
static (1),
dynamic (2),
pat (3),
transparent (4)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"NAT type.
static - Translate a specific virtual IP network to a specific real IP
network. TCP, UDP and ICMP sessions originated both in real and
virtual networks will be translated.
dynamic - (Concurrent) Translate real IP network to larger or equal virtual
IP network. TCP, UDP and ICMP sessions originated in virtual
networks only can be translated and sessions originated in real
networks will be rejected. A session that starts in the NAT system
will be active until there will be no traffic for aging timeout
period.
pat - (Port Address Translation/ Single IP).
Translate one real IP address to virtual IP network. TCP, UDP and
ICMP sessions originated in virtual network only can be translated,
sessions originated in real network will be rejected. A session
that starts in the NAT system will be active until there will be no
traffic for aging timeout period.
transparent - In transparent mode all frames belonging to the defined IP
network will be forwarded with no translation: virtual = real."
::= { rtrNatIfConfEntry 6 }
-- *************************************
-- Port Address Translation
-- *************************************
rtrPatTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrPatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Port Address Translation (PAT - single IP NAT) configuration Table."
::= {rtrNat 2}
rtrPatEntry OBJECT-TYPE
SYNTAX RtrPatEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry describe unique mapping between real IP address,
range of ports and protocol, to local (virtual) IP address.
Ports are used in the TCP (rfc793) to name the ends of logical
connections which carry long term conversations.
For the purpose of providing services to unknown callers,
a service contact port is defined. "
INDEX { rtrPatIdx }
::= { rtrPatTable 1 }
RtrPatEntry ::=
SEQUENCE {
rtrPatIdx Integer32,
rtrPatRealAddress IpAddress,
rtrPatVirtualAddress IpAddress,
rtrPatLowestPort Integer32,
rtrPatHighestPort Integer32,
rtrPatProtocol INTEGER,
rtrPatStatus RowStatus
}
rtrPatIdx OBJECT-TYPE
SYNTAX Integer32 (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Running index for PAT table."
::= { rtrPatEntry 1 }
rtrPatRealAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The real IP Address used for translation "
::= { rtrPatEntry 2 }
rtrPatVirtualAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The virtual IP Address used for translation"
::= { rtrPatEntry 3 }
rtrPatLowestPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Lowest Port number for this PAT entry "
::= { rtrPatEntry 4 }
rtrPatHighestPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Highest Port number for this PAT entry "
::= { rtrPatEntry 5 }
rtrPatProtocol OBJECT-TYPE
SYNTAX INTEGER
{
tcp (6),
udp (17)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Protocol selected.
This Protocol and port range (lowest port - highest port)
define the application (FTP, Telnet, SMTP etc.).
Protocol enumaration numbers correspond to
IP header 'protocol' field "
::= { rtrPatEntry 6 }
rtrPatStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables creating and deleting
entries of the table."
::= { rtrPatEntry 7 }
-- ************************************************
-- FACS MIB
-- ************************************************
rtrFACS OBJECT IDENTIFIER ::= { radRouter 5 }
rtrFACSDefaultAction OBJECT-TYPE
SYNTAX INTEGER {
block(1),
forward(2),
blockAndReport(129)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Used to define the default action for the device, when no
FACS statements applicable to a given frame are defined."
-- DEFVAL { 1 }
::= { rtrFACS 1 }
rtrFACSActTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrFACSActEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of FACS action."
::= { rtrFACS 2 }
rtrFACSActEntry OBJECT-TYPE
SYNTAX RtrFACSActEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each rtrFACSActEntry consist of the following parameters"
INDEX {rtrFACSActType,
rtrFACSActIfIndex}
::= { rtrFACSActTable 1 }
RtrFACSActEntry ::= SEQUENCE {
rtrFACSActType INTEGER,
rtrFACSActIfIndex Integer32,
rtrFACSAction INTEGER,
rtrFACSActiveDB INTEGER
}
rtrFACSActType OBJECT-TYPE
SYNTAX INTEGER {
tx(1),
rx(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter indicates on which FACS Table the FACS
action will preform."
::= { rtrFACSActEntry 1 }
rtrFACSActIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface to which this FACS entry is applicable."
::= { rtrFACSActEntry 2 }
rtrFACSAction OBJECT-TYPE
SYNTAX INTEGER {
none(1),
eraseIP(2),
eraseDECnet(3),
eraseIPX(4),
eraseBrg(5),
replaceIP(6),
replaceIPX(8),
replaceBrg(9),
backupIP(10),
backupIPX(12),
backupBrg(13)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The management station that sends a SET request for one of these actions
with indexes rtrFACSType and rtrFACSIfIndex defines the type and the
interface Id for which all FACS statements are to be erased.
If no interface or no type is specified, all FACS statements for a
protocol are erased."
-- DEFVAL { 1 }
::= { rtrFACSActEntry 3 }
rtrFACSActiveDB OBJECT-TYPE
SYNTAX INTEGER {
active(1),
temporary(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter will point on which Facs DataBase the SNMP agent
read. The Active dataBase is Read Only. The user may change FACS
statements in the temporary DataBase and then write it to the
Active DB."
::= { rtrFACSActEntry 4}
rtrFACSTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrFACSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The table of FACS statment."
::= { rtrFACS 3 }
rtrFACSEntry OBJECT-TYPE
SYNTAX RtrFACSEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each FACS statment consists of the following parameters"
INDEX {rtrFACSIfIndex,
rtrFACSProtocolType,
rtrFACSType,
rtrFACSIndex }
::= { rtrFACSTable 1 }
RtrFACSEntry ::= SEQUENCE {
rtrFACSIfIndex Integer32,
rtrFACSProtocolType INTEGER,
rtrFACSType INTEGER,
rtrFACSIndex Integer32,
rtrFACSSrcAdd OCTET STRING ,
rtrFACSSrcAddMask OCTET STRING,
rtrFACSDesAdd OCTET STRING,
rtrFACSDesAddMask OCTET STRING,
rtrFACSOperation INTEGER,
rtrFACSNetFiltering INTEGER,
rtrFACSSocketNum Integer32,
rtrFACSMask1Id Integer32,
rtrFACSMask2Id Integer32,
rtrFACSStatus INTEGER
}
rtrFACSIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The interface to which this FACS entry is applicable.
For applications this variables is always 0."
::= { rtrFACSEntry 1 }
rtrFACSProtocolType OBJECT-TYPE
SYNTAX INTEGER{
ip(1),
ipx(2),
dec(3),
bridge(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter define the protocol the Security Access Control
is applicable."
::= { rtrFACSEntry 2 }
rtrFACSType OBJECT-TYPE
SYNTAX INTEGER {
tx(1),
rx(2),
cod(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" The Mode of in which this FACS statement operates.
For applications this variable is always rx(2)."
::= { rtrFACSEntry 3 }
rtrFACSIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Index to the FACS Table. "
::= { rtrFACSEntry 4 }
rtrFACSSrcAdd OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The size of the octet string will be according to the protocol type
defined in rtrFACSProtocolType."
::= { rtrFACSEntry 5 }
rtrFACSSrcAddMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Source-address mask ."
::= { rtrFACSEntry 6 }
rtrFACSDesAdd OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination-address The size of the octet string will be according to the
protocol type define in rtrFACSProtocolType ."
::= { rtrFACSEntry 7 }
rtrFACSDesAddMask OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Destination-address mask ."
::= { rtrFACSEntry 8 }
rtrFACSOperation OBJECT-TYPE
SYNTAX INTEGER {
block(1),
forward(2),
permit(3), -- For Connect On demand Only
deny(4), -- For Connect On demand Only
blockAndReport(129)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"... ."
::= { rtrFACSEntry 9 }
rtrFACSNetFiltering OBJECT-TYPE
SYNTAX INTEGER {
none(1),
l2multicast(2), --applicable for Bridge protocol
arp(3), --applicable for ip protocol
icmp(4), --applicable for ip protocol
ip(5), --applicable for ip protocol
udp(6), --applicable for ip protocol
tcp(7), --applicable for ip protocol
decnet(8), --applicable for decnet protocol
ipx(9) --applicable for ipx protocol
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"... ."
::= { rtrFACSEntry 10 }
rtrFACSSocketNum OBJECT-TYPE --applicable for ip,ipx protocol
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Port/socket number for different applications
0 is default meaning not applicable.
none(1),
ftp(21),
telnet(23),
smtp(25),
tftp(69),
snmp(161),
snmpTrap(162),
rip(520),
sapIPX(1106),
ripIPX(1107) "
::= { rtrFACSEntry 11}
rtrFACSMask1Id OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Index into RND mask table FACS/COD Type) ."
::= { rtrFACSEntry 12}
rtrFACSMask2Id OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" Index into RND mask table FACS/COD according to
the value of rtrFACSType ."
::= { rtrFACSEntry 13}
rtrFACSStatus OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
createRequest(2),
underCreation(3),
invalid(4) -- logically deleted
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The status of a table entry."
::= { rtrFACSEntry 14}
rtrFACSFrameData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..256))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Data from the frame that violated a FACS Filter."
::= { rtrFACS 4 }
-- **************** FACS Group Ends *******************
-- ************************************************
-- Bridge ports Configuration MIB
-- ************************************************
-- rtrBridge OBJECT IDENTIFIER ::= { radRouter 7 }
rtrBridgePortConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrBridgePortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Table of the bridge ports"
::= { rtrBridge 1 }
rtrBridgePortConfigEntry OBJECT-TYPE
SYNTAX RtrBridgePortConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry defines a bridge port "
INDEX { rtrBridgePortCIndex }
::= { rtrBridgePortConfigTable 1 }
RtrBridgePortConfigEntry ::= SEQUENCE {
rtrBridgePortCIndex
Integer32,
rtrBridgePortCIf
Integer32,
rtrBridgePortCStatus
RowStatus
}
rtrBridgePortCIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This is the index of the bridge port. It is the same
as 'dot1dBasePort' of the Bridge MIB."
::= {rtrBridgePortConfigEntry 1}
rtrBridgePortCIf OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The config ifIndex the bridge port is sitting on. "
::= {rtrBridgePortConfigEntry 2}
rtrBridgePortCStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The status of the RtrBridgePortConfigEntry.
Creating and destroying the bridge port is done by this
variable."
::= {rtrBridgePortConfigEntry 3}
radRouterConfig OBJECT IDENTIFIER ::= { radRouter 9 }
-- The Router's Configuration Table
rtrConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Router's Configuration table."
::= { radRouterConfig 1 }
rtrConfigEntry OBJECT-TYPE
SYNTAX RtrConfigEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Router's Configuration table."
INDEX { rtrConfigIndex }
::= { rtrConfigTable 1 }
RtrConfigEntry ::=
SEQUENCE {
rtrConfigIndex INTEGER,
-- 2 is NOT used
rtrConfigArpAgingTime Integer32,
-- 4 is NOT used
rtrConfigClassifierTosMask Integer32
}
rtrConfigIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Router's Index."
::= { rtrConfigEntry 1 }
-- { rtrConfigEntry 2 } is NOT used
rtrConfigArpAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"ARP Aging Time."
::= { rtrConfigEntry 3 }
-- { rtrConfigEntry 4 } is NOT used
rtrConfigClassifierTosMask OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Classifier's TOS Mask,
as follows:
0x1C for DTR -- rfc795
0x1E for Cisco
0xE0 for Precedence -- rfc795
0xFC for Diffserv
Else for Manual
."
::= { rtrConfigEntry 5 }
-- { radRouterConfig 2 } is NOT used
-- The Router's Forwarding Table
rtrFwdTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtrFwdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Router's Forwarding Table."
::= { radRouterConfig 3 }
rtrFwdEntry OBJECT-TYPE
SYNTAX RtrFwdEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Router's Forwarding table."
INDEX { rtrFwdIdx, rtrFwdIpAddress,
rtrFwdIpMask, rtrFwdRuleIdx }
::= { rtrFwdTable 1 }
RtrFwdEntry ::=
SEQUENCE {
rtrFwdIdx Integer32,
rtrFwdIpAddress IpAddress,
rtrFwdIpMask IpAddress,
rtrFwdRuleIdx Integer32,
rtrFwdRowStatus RowStatus,
rtrFwdNextHop IpAddress,
rtrFwdIfIndex Integer32,
rtrFwdType INTEGER,
rtrFwdProto INTEGER,
rtrFwdEthQueue Integer32,
rtrFwdMetric1 Integer32
}
rtrFwdIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Router Index."
::= { rtrFwdEntry 1 }
rtrFwdIpAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Destination IP Address."
::= { rtrFwdEntry 2 }
rtrFwdIpMask OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Mask IP address."
::= { rtrFwdEntry 3 }
rtrFwdRuleIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Rule's Number."
::= { rtrFwdEntry 4 }
rtrFwdRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables the user to
create/delete entries in this table.
Entry of Type rtrFwdType = staticRouting(3)
are created by the user.
Only this type of entries can be deleted by the user.
Entry of Type rtrFwdType = interface(2)
are created/deleted automatically by the Agent
when the user creates/deletes an interface of the Router."
::= { rtrFwdEntry 5 }
rtrFwdNextHop OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the IP Address of the Next Hop."
::= { rtrFwdEntry 6 }
rtrFwdIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the Interface Index."
::= { rtrFwdEntry 7 }
rtrFwdType OBJECT-TYPE
SYNTAX INTEGER {
other (1), -- not specified by this MIB
reject (2), -- route which discards traffic
local (3), -- local interface
remote (4) -- remote destination
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of route. Note that local(3) refers
to a route for which the next hop is the final
destination; remote(4) refers to a route for
which the next hop is not the final destina-
tion.
Routes which do not result in traffic forwarding or
rejection should not be displayed even if the
implementation keeps them stored internally.
reject (2) refers to a route which, if matched, discards
the message as unreachable. This is used in some
protocols as a means of correctly aggregating routes."
::= { rtrFwdEntry 8 }
rtrFwdProto OBJECT-TYPE
SYNTAX INTEGER {
other (1), -- not specified
local (2), -- local interface
netmgmt (3), -- static route
rip (8), -- Berkeley RIP or RIP-II
lis (41) -- Logical IP Subnet
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The routing mechanism via which this route was
learned. Inclusion of values for gateway routing
protocols is not intended to imply that
hosts should support those protocols."
::= { rtrFwdEntry 9 }
rtrFwdEthQueue OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the ETH Queue number."
::= { rtrFwdEntry 10 }
rtrFwdMetric1 OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The primary routing metric for this route.
The semantics of this metric are determined by
the routing-protocol specified in the route's
rtrFwdProto value. If this metric is not
used, its value should be set to -1."
DEFVAL { -1 }
::= { rtrFwdEntry 11 }
-- **************** Router Bridge Port Group Ends *******************
-- Traps
rtrFACSViolation NOTIFICATION-TYPE
OBJECTS { rtrFACSFrameData, rtrFACSProtocolType }
STATUS current
DESCRIPTION
"The trap is sent for every violation of a FACS filter."
::= { radSysRtrEvents 1 }
rtrSwDwnLoadTrap NOTIFICATION-TYPE
OBJECTS { fileName }
STATUS current
DESCRIPTION
"The trap is sent after the tftp download of the software
and before the decompression and reset operations."
::= { radSysRtrEvents 2 }
--
-- file :v:\doc\rdv\mib\ver495\atm\layer2.txt
--
--
-- file: v:\doc\rdv\mib\ver495\atm\layer2.txt
--
--RTR-MIB
--
--Last update: 25-Sep-2002
--By: Shay Harari
-- ************************************************
-- Link Layer (layer 2) MIB
-- ************************************************
atmLayer2 OBJECT IDENTIFIER ::= {radAtm 7}
atmLayer2XVclTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLayer2XVclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of VCL table, which is created
for each LAN VCC."
::= { atmLayer2 1 }
atmLayer2XVclEntry OBJECT-TYPE
SYNTAX AtmLayer2XVclEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmVclTable.
This table augments the RFC2515 VCL table."
AUGMENTS { atmVclEntry }
::= { atmLayer2XVclTable 1 }
AtmLayer2XVclEntry ::= SEQUENCE {
atmLayer2XVclConnMode INTEGER,
atmLayer2XVclGroupIdx Integer32
}
atmLayer2XVclConnMode OBJECT-TYPE
SYNTAX INTEGER {
main (1),
sub (2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Each valid LAN VCC is either Main or Sub.
This parameter is configured only once on creation of a LAN VCC.
It can not be changed after creation. In order to change the Mode,
user should delete the connection and create a new one.
main - A LAN VCC, which holds its own bridge port.
Bridge forwarding and Bridge learning is performed only on Main
VCCs.
For working on a transparent bridge, that doesn't perform
layer 2 priority mapping, a Main VCC should be opened, which
is the default connection Mode.
When working with layer 2 priority, a group of LAN VCCs should
be configured, where each group will be associated with only
one Main VCC.
A specific Main can not be used by more than one group.
sub - A LAN VCC is not part of the bridging mechanism.
A Sub VCC automatically inherit some general definitions from
Main VCC of its group: ATM Slot/Port and LAN Slot/Port.
Max number of Sub VCCs allowed per group is:
[Number of Priorities - 1]."
::= { atmLayer2XVclEntry 1 }
atmLayer2XVclGroupIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group identifier.
A VCC Group identifier = 0 if the VCC was not associated with a
group yet.
This value is updated according to the group identifier set by
atmLayer2GroupTable."
::= { atmLayer2XVclEntry 2 }
atmLayer2GroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLayer2GroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains groups and their members.
A group is a bundle of VCCs, which acts as different queues.
Main and Sub VCCs should have the same ATM slot and port,
and the same LAN slot and port.
Each group contains: 1 to <number of priorities> VCCs."
::= { atmLayer2 2 }
atmLayer2GroupEntry OBJECT-TYPE
SYNTAX AtmLayer2GroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmLayer2GroupTable.
The indexes: ifIndex, atmVclVpi and atmVclVci indicate
the Network ATM End-Point.
Upon a group creation, one Main VCC must be added first.
After the group was created, Sub VCCs may be added to the group."
INDEX { atmLayer2GroupIdx, ifIndex, atmVclVpi, atmVclVci }
::= { atmLayer2GroupTable 1 }
AtmLayer2GroupEntry ::= SEQUENCE {
atmLayer2GroupIdx Integer32,
atmLayer2GroupRowStatus RowStatus,
atmLayer2GroupConnMode INTEGER,
atmLayer2GroupConnPriority OCTET STRING,
atmLayer2GroupName SnmpAdminString
}
atmLayer2GroupIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group identifier.
0 is not a valid index."
::= { atmLayer2GroupEntry 1 }
atmLayer2GroupRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Creation/Deletion of rows in the table, and indication of the
entry's status."
::= {atmLayer2GroupEntry 2 }
atmLayer2GroupConnMode OBJECT-TYPE
SYNTAX INTEGER {
main (1),
sub (2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Each valid LAN VCC is either Main or Sub as configured in
atmLayer2XVclTable."
::= { atmLayer2GroupEntry 3 }
atmLayer2GroupConnPriority OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This parameter is configured by atmLayer2PriorityRx from
atmLayer2PriorityTable.
Each bit in the Octet represents a specific priority as follows:
MSB 7 6 5 4 3 2 1 0 LSB -> Priorities
|____________________|
1 0 0 1 0 0 0 1 -> Value
In this example, a certain VCC has several priorities: 0, 4 and 7."
::= { atmLayer2GroupEntry 4 }
atmLayer2GroupName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE (1..32))
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Group name. Configured by the user.
The name is unique per system.
For atmLayer2GroupIdx=0, the name will be null."
::= { atmLayer2GroupEntry 5 }
atmLayer2PriorityTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLayer2PriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table maps all priorities inside a group.
Several priorities might be mapped to the same VCC.
Upon priority change, the agent will update the VCCs of the
changed priority in this table, and will update -
atmLayer2GroupConnPriority parameter of both former and new owners
of the changed priority.
Changing a VCC value is actually a change of three parameters
simultaneously: atmLayer2PriorityIfIndex, atmLayer2PriorityVclVpi
and atmLayer2PriorityVclVci. Otherwise, the set will be rejected,
since there might be that such VCC doesn't exist in the specific
group."
::= { atmLayer2 3 }
atmLayer2PriorityEntry OBJECT-TYPE
SYNTAX AtmLayer2PriorityEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmLayer2PriorityTable.
Each entry is a Network ATM End-Point per priority.
Upon a group creation, all priorities are mapped to the Main VCC.
Number of entries per group is according to the number of
priorities enabled. (For example, for Max priorities = 8,
the agent will create 8 entries)."
INDEX { atmLayer2PriorityGroupIdx, atmLayer2PriorityRx }
::= { atmLayer2PriorityTable 1 }
AtmLayer2PriorityEntry ::= SEQUENCE {
atmLayer2PriorityGroupIdx Integer32,
atmLayer2PriorityRx INTEGER,
atmLayer2PriorityIfIndex InterfaceIndex,
atmLayer2PriorityVclVpi Integer32,
atmLayer2PriorityVclVci Integer32
}
atmLayer2PriorityGroupIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The group identifier."
::= { atmLayer2PriorityEntry 1 }
atmLayer2PriorityRx OBJECT-TYPE
SYNTAX INTEGER (1..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The priority values.
The used values are 0-7, but since this value is part of the index
of the table, and in order to avoid '0' as an index, the index syntax
is 1..8, but the real value is atmLayer2PriorityRx-1:
0 - for Low priority.
7 - for High priority."
::= { atmLayer2PriorityEntry 2 }
atmLayer2PriorityIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"ATM ifIndex of the network End-Point."
::= { atmLayer2PriorityEntry 3 }
atmLayer2PriorityVclVpi OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Vpi of the network End-Point."
::= { atmLayer2PriorityEntry 4 }
atmLayer2PriorityVclVci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"Vci of the network End-Point."
::= { atmLayer2PriorityEntry 5 }
atmLayer2GroupIndexNext OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object contains an appropriate value to
be used for atmLayer2GroupIdx when creating
entries in the atmLayer2GroupTable. The value
0 indicates that no unassigned entries are
available. To obtain the atmLayer2GroupIdx
value for a new entry, the manager gets
the current value of this object. The next index
will be of the first unassigned entry. It will be
provided by checking the assigned entries."
::= { atmLayer2 4 }
--VLAN
atmLayer2CfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmLayer2CfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Bridge configuration Table. This table supports multi-bridge
and bridge features within an ATM device."
::= { atmLayer2 5 }
atmLayer2CfgEntry OBJECT-TYPE
SYNTAX AtmLayer2CfgEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmLayer2CfgTable.
Each entry in this table contains the bridging attributes for
both Ethernet and ATM sides.
The interface index is the Ethernet port interface.
For Ace52: this object represents the Bridge ifIndex."
INDEX { ifIndex }
::= { atmLayer2CfgTable 1 }
AtmLayer2CfgEntry ::= SEQUENCE {
atmLayer2CfgBridgingMode INTEGER,
atmLayer2CfgVlanMode INTEGER,
atmLayer2CfgAtmAcceptableFrameType INTEGER,
atmLayer2CfgAtmIngressFiltering TruthValue,
atmLayer2CfgAtmTxFrameType INTEGER,
atmLayer2CfgEthAcceptableFrameType INTEGER,
atmLayer2CfgBridgeAction INTEGER,
atmLayer2CfgLearningMode INTEGER,
atmLayer2CfgAgingTime Integer32
}
atmLayer2CfgBridgingMode OBJECT-TYPE
SYNTAX INTEGER {
accessOnly(1),
accessAndSwitching (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Bridging mode can be one of the following:
ATM <> Ethernet - Bridging is between the Ethernet
port and the ATM port (there is no bridging between VCs).
ATM <> Ethernet + ATM - Bridging is done both between
the Ethernet port and the ATM port and also between VCs."
::= { atmLayer2CfgEntry 1 }
atmLayer2CfgVlanMode OBJECT-TYPE
SYNTAX INTEGER {
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"VLAN Mode. Upon Mode changing, all LAN VCCs will be deleted
by the agent from all tables that include LAN VCCs."
::= { atmLayer2CfgEntry 2 }
atmLayer2CfgAtmAcceptableFrameType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
admitAll (2),
admitOnlyVlanTagged (3),
admitOnlyUnTagged (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Frame Type that will be acceptable by the VCCs that
are associated with this Ethernet port.
Frames which don't match the selected type will be discarded.
admitAll - all frames will be accepted.
admitOnlyVlanTagged - only Tagged frames will be accepted.
admitOnlyUnTagged - only unTagged frames will be accepted."
::= { atmLayer2CfgEntry 3 }
atmLayer2CfgAtmIngressFiltering OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"For the VCCs that are associated with this Ethernet port,
when this is true(1) the device will discard incoming
frames for VLANs which do not include this Port in its
Member set. When false(2), the port will accept all
incoming frames."
::= { atmLayer2CfgEntry 4 }
atmLayer2CfgAtmTxFrameType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
unTagged (2),
tagged (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Frame Type that will be transmitted by the VCCs that
are associated with this Ethernet port.
unTagged - The transmitted frames will be unTagged.
tagged - The transmitted frames will be Tagged."
::= { atmLayer2CfgEntry 5 }
atmLayer2CfgEthAcceptableFrameType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable (1),
admitAll (2),
admitOnlyVlanTagged (3),
admitOnlyUnTagged (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The Frame Type that this Ethernet port will accept.
(for ACE-52: the Frame Type that this Bridge will accept)
This parameter is notApplicable for atmLayer2VlanMode=disable.
Frames which don't match the selected type will be discarded.
admitAll - all frames will be accepted.
admitOnlyVlanTagged - only Tagged frames will be accepted.
admitOnlyUnTagged - only unTagged frames will be accepted."
::= { atmLayer2CfgEntry 6 }
atmLayer2CfgBridgeAction OBJECT-TYPE
SYNTAX INTEGER {
deleteLanTable (7),
noOp (255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables to perform the specified action on the
selected port."
::= { atmLayer2CfgEntry 7 }
atmLayer2CfgLearningMode OBJECT-TYPE
SYNTAX INTEGER {
svl (1),
ivl (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object specifies the mode of the learning process of a bridge.
svl - Shared VLAN process. If an individual MAC Address is learned
in one VLAN, this information is used in forwarding decisions
taken for that address for all other VLANs.
ivl - Independent VLAN process. If an individual MAC Address is learned
in one VLAN, this information is not used in forwarding decisions
taken for that address for all other VLANs."
::= { atmLayer2CfgEntry 8 }
atmLayer2CfgAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout period in seconds for aging out
dynamically learned forwarding information."
::= { atmLayer2CfgEntry 9 }
--
-- file :v:\doc\rdv\mib\ver470\atm\frAtm.txt
--
--
-- file: v:\doc\rdv\mib\ver470\atm\frAtm.txt
--
--FR-ATM-IWF-X-MIB
--
--Last update: 28-Feb-2001
--By: Ilana Schvetz
--atmSuPortFr OBJECT IDENTIFIER ::= { atmSuPort 4 }
radAtmFr OBJECT IDENTIFIER ::= {radAtm 8}
frAtmIwfXConnectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrAtmIwfXConnectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of frAtmIwfXConnectionTable from
RFC2955."
::= { radAtmFr 1 }
frAtmIwfXConnectionEntry OBJECT-TYPE
SYNTAX FrAtmIwfXConnectionEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in frAtmIwfXConnectionTable.
This table augments the RFC2955."
AUGMENTS { frAtmIwfConnectionEntry }
::= { frAtmIwfXConnectionTable 1 }
FrAtmIwfXConnectionEntry ::= SEQUENCE {
frAtmIwfXConnMode INTEGER,
frAtmIwfXConnSscsDlci Integer32
}
frAtmIwfXConnMode OBJECT-TYPE
SYNTAX INTEGER { service(1), network(2) }
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"FR IWF Mode.
service - Service InterWorking (FRF.8),
network - Network InterWorking (FRF.5)."
::= { frAtmIwfXConnectionEntry 1 }
frAtmIwfXConnSscsDlci OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is relevant for
frAtmIwfXConnMode=network (FRF.5) only.
This parameter allow configuration of the
FR SSCS DLCI that is transferred to the
remote FR unit."
::= { frAtmIwfXConnectionEntry 2 }
--
-- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt
--
--
-- file :v:\doc\rdv\mib\ver495\atm\radaal5.txt
--
--Last update: 19-Nov-2002 by Ilana Schvetz
-- ATM-X-MIB DEFINITIONS ::= BEGIN
--
--atmGen OBJECT IDENTIFIER ::= {radAtm 2}
--atmPerfHistory OBJECT IDENTIFIER ::= {atmGen 1}
--atmIfPerformance OBJECT IDENTIFIER ::= {atmPerfHistory 1}
-- AAL5 Virtual Channel Connection Performance Statistics
-- Table
-- This table contains the AAL5 extension
-- performance statistics of a VCC at the
-- interface associated with an AAL5 entity in an ATM
-- host or ATM switch.
aal5VccXTable OBJECT-TYPE
SYNTAX SEQUENCE OF Aal5VccXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension to AAL5 VCC Table."
::= { atmIfPerformance 4 }
aal5VccXEntry OBJECT-TYPE
SYNTAX Aal5VccXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This list contains the additional AAL5 VCC
performance parameters and is indexed
by ifIndex values of AAL5 interfaces
and the associated VPI/VCI values."
AUGMENTS { aal5VccEntry }
::= { aal5VccXTable 1 }
Aal5VccXEntry ::= SEQUENCE {
aal5VccInFrames Counter32,
aal5VccOutFrames Counter32,
aal5VccUnknownProtocolFrames Counter32
}
aal5VccInFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames received via this interface."
::= { aal5VccXEntry 1 }
aal5VccOutFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The total number of frames transmitted out of the
interface."
::= { aal5VccXEntry 2 }
aal5VccUnknownProtocolFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of frames that were discarded due to unsupported
protocol encapsulation on this VCC."
::= { aal5VccXEntry 3 }
aal5VccCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF Aal5VccCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AAL5 Current table."
::= { atmIfPerformance 5 }
aal5VccCurrentEntry OBJECT-TYPE
SYNTAX Aal5VccCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the AAL5 Current table."
INDEX { ifIndex, aal5VccVpi, aal5VccVci }
::= { aal5VccCurrentTable 1 }
Aal5VccCurrentEntry
::= SEQUENCE {
aal5VccCurrentInFrames
Gauge32,
aal5VccCurrentOutFrames
Gauge32,
aal5VccCurrentUnknownProtocolFrames
Gauge32,
aal5VccCurrentCrcErrors
Gauge32,
aal5VccCurrentLengthError
Gauge32,
aal5VccCurrentInputCongestionDropped
Gauge32,
aal5VccCurrentOutputCongestionDropped
Gauge32
}
aal5VccCurrentInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the AAL5 interface in the current 15 minute
interval."
::= { aal5VccCurrentEntry 1 }
aal5VccCurrentOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the AAL5 interface in the current 15 minute
interval."
::= { aal5VccCurrentEntry 2 }
aal5VccCurrentUnknownProtocolFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames that were
discarded due to unsupported protocol encapsulation,
encountered by the AAL5 interface in the current 15 minute
interval."
::= { aal5VccCurrentEntry 3 }
aal5VccCurrentCrcErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AAL5 CPCS PDUs
received with CRC-32 errors, encountered by the AAL5
interface in the current 15 minute interval."
::= { aal5VccCurrentEntry 4 }
aal5VccCurrentLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the AAL5 interface in the
current 15 minute interval."
::= { aal5VccCurrentEntry 5 }
aal5VccCurrentInputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
dropped frames due to congestion, encountered by
the AAL5 interface on the Receive direction
in the current 15 minute interval."
::= { aal5VccCurrentEntry 6 }
aal5VccCurrentOutputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
dropped frames due to congestion, encountered by
the AAL5 interface on the Transmit direction
in the current 15 minute interval."
::= { aal5VccCurrentEntry 7 }
-- Interval Table
aal5VccIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Aal5VccIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AAL5 Interval table."
::= { atmIfPerformance 6 }
aal5VccIntervalEntry OBJECT-TYPE
SYNTAX Aal5VccIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the AAL5 Interval table."
INDEX { ifIndex, aal5VccVpi, aal5VccVci, aal5VccIntervalNumber }
::= { aal5VccIntervalTable 1 }
Aal5VccIntervalEntry
::= SEQUENCE {
aal5VccIntervalNumber
Integer32,
aal5VccIntervalInFrames
Gauge32,
aal5VccIntervalOutFrames
Gauge32,
aal5VccIntervalUnknownProtocolFrames
Gauge32,
aal5VccIntervalCrcErrors
Gauge32,
aal5VccIntervalLengthError
Gauge32,
aal5VccIntervalInputCongestionDropped
Gauge32,
aal5VccIntervalOutputCongestionDropped
Gauge32
}
aal5VccIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { aal5VccIntervalEntry 1 }
aal5VccIntervalInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the AAL5 interface in one of the previous
96, individual 15 minute, intervals."
::= { aal5VccIntervalEntry 2 }
aal5VccIntervalOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the AAL5 interface in in one of the previous
96, individual 15 minute, intervals."
::= { aal5VccIntervalEntry 3 }
aal5VccIntervalUnknownProtocolFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames that were
discarded due to unsupported protocol encapsulation,
encountered by the AAL5 interface in one of the previous
96, individual 15 minute, intervals."
::= { aal5VccIntervalEntry 4 }
aal5VccIntervalCrcErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of AAL5 CPCS PDUs
received with CRC-32 errors, encountered by the AAL5
interface in one of the previous 96, individual 15 minute,
intervals."
::= { aal5VccIntervalEntry 5 }
aal5VccIntervalLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the AAL5 interface in one
of the previous 96, individual 15 minute, intervals."
::= { aal5VccIntervalEntry 6 }
aal5VccIntervalInputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the AAL5 interface on
the Receive direction in one of the previous 96, individual
15 minute, intervals"
::= { aal5VccIntervalEntry 7 }
aal5VccIntervalOutputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the AAL5 interface on
the Transmit direction in one of the previous 96, individual
15 minute, intervals"
::= { aal5VccIntervalEntry 8 }
-- END
--
-- file :v:\doc\rdv\mib\ver495\ethif.txt
--
--01/08/2000
--By: Smadar Tauber
--s:\doc\rdv\mib\ver485\ethIf.txt
--File: ethIf.txt
--EthIf MIB - separated from mpmx.txt
--diverseIfWanGen OBJECT IDENTIFIER ::= {wanGen 6}
--Last update: 27-Jan-2003 by Shay Hararim
--
-- diverseIf - diverse NON-WAN interfaces of WAN products
--
--Ethernet Interface
ethIf OBJECT IDENTIFIER ::= {diverseIfWanGen 1} --Ethernet Interface
ethIfTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table."
::= { ethIf 1}
ethIfEntry OBJECT-TYPE
SYNTAX EthIfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in table."
INDEX {ethIfIdx}
::= {ethIfTable 1}
EthIfEntry ::=
SEQUENCE {
ethIfIdx Integer32,
ethMode INTEGER,
ethBridgingMode INTEGER,
ethEncapsulationCRCMode INTEGER,
ethBackPressure INTEGER,
ethLimit4 INTEGER,
ethSkipInitReset INTEGER,
ethMulticastBlock INTEGER,
ethBroadcastBlock INTEGER,
ethSpeed INTEGER,
ethRip2 INTEGER,
ethPortPriority INTEGER,
ethPortMngEnable INTEGER,
ethFlowCtrlMacAddress MacAddress
}
ethIfIdx OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A unique index of the ethernet interface/port."
::= {ethIfEntry 1}
ethMode OBJECT-TYPE
SYNTAX INTEGER
{
halfDuplex (1),
fullDuplex (2),
notApplicable(255)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the Ethernet mode of operation."
::= {ethIfEntry 2}
ethBridgingMode OBJECT-TYPE
SYNTAX INTEGER
{
filtered (1),
transparent (2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates the bridging mode of the Ethernet
interface. "
::= {ethIfEntry 3}
ethEncapsulationCRCMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
withCRC (2),
withoutCRC (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object define the encapsulation type requested for the
Ethernet interface. It indicates if we transfer the Ethernet
frame to the other side with or without the CRC. "
::= {ethIfEntry 4}
ethBackPressure OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to enable or disable Back pressure.
Back Pressure is a flow control parameter. "
::= {ethIfEntry 5}
ethLimit4 OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
disable (2),
enable (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter determine the Back off algorithm mode.
Every 4 following collisions the Framer will be thrown out
(4 times more than usuall)."
::= {ethIfEntry 6}
ethSkipInitReset OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
notSkip (2),
skip (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether read status on reset. "
::= {ethIfEntry 7}
ethMulticastBlock OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unBlock (2),
block (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to send multicast message to WAN from LAN or not. "
::= {ethIfEntry 8}
ethBroadcastBlock OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
unBlock (2),
block (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to send broadcast message to WAN from LAN or not."
::= {ethIfEntry 9}
ethSpeed OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
s10Mbps (2),
s100Mbps (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the line speed."
::= {ethIfEntry 10}
ethRip2 OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether to send RIP II message
to WAN from LAN or not"
::= {ethIfEntry 11}
ethPortPriority OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
none (2),
fixed (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines if priority is to
be considered for this Port."
::= {ethIfEntry 12}
ethPortMngEnable OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
no (2),
yes (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines whether management data can pass through this Port."
::= {ethIfEntry 13}
ethFlowCtrlMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"In case of flow control - transmit frame with this specific MAC address
to inform the other end to stop sending frames.
Default: 01.80.C2.00.00.01."
::= {ethIfEntry 14}
ethIfPerformance OBJECT IDENTIFIER ::= {ethIf 2}
ethIfCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Current table."
::= { ethIfPerformance 1}
ethIfCurrentEntry OBJECT-TYPE
SYNTAX EthIfCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet Current table."
INDEX {ethIfCurrentIndex}
::= {ethIfCurrentTable 1}
EthIfCurrentEntry ::=
SEQUENCE {
ethIfCurrentIndex
Integer32,
ethIfCurrentStatus
OCTET STRING,
ethIfCurrentInFrames
Gauge32,
ethIfCurrentInOctets
Gauge32,
ethIfCurrentAlignmentErrors
Gauge32,
ethIfCurrentFCSErrors
Gauge32,
ethIfCurrentLengthError
Gauge32,
ethIfCurrentOutFrames
Gauge32,
ethIfCurrentOutOctets
Gauge32,
ethIfCurrentSingleCollisionFrames
Gauge32,
ethIfCurrentMultipleCollisionFrames
Gauge32,
ethIfCurrentDeferredTransmissions
Gauge32,
ethIfCurrentLateCollisions
Gauge32,
ethIfCurrentCarrierSenseErrors
Gauge32,
ethIfCurrentInputCongestionDropped
Gauge32,
ethIfCurrentOutputCongestionDropped
Gauge32
}
ethIfCurrentIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Ethernet interface.
It may be ifIndex."
::= { ethIfCurrentEntry 1 }
ethIfCurrentStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { ethIfCurrentEntry 2 }
ethIfCurrentInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the Ethernet interface in the current 15 minute
interval."
::= { ethIfCurrentEntry 3 }
ethIfCurrentInOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received octets,
encountered by the Ethernet interface in the current 15 minute
interval."
::= { ethIfCurrentEntry 4 }
ethIfCurrentAlignmentErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
which are not complete (The result of dividing the number
of bits by 8 is not an Integer), encountered by the Ethernet
interface in the current 15 minute interval."
::= { ethIfCurrentEntry 5 }
ethIfCurrentFCSErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
that didn't pass the FCS test, encountered by the Ethernet
interface in the current 15 minute interval."
::= { ethIfCurrentEntry 6 }
ethIfCurrentLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the Ethernet interface in
the current 15 minute interval."
::= { ethIfCurrentEntry 7 }
ethIfCurrentOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the Ethernet interface in the current 15 minute
interval."
::= { ethIfCurrentEntry 8 }
ethIfCurrentOutOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted octets,
encountered by the Ethernet interface in the current 15 minute
interval."
::= { ethIfCurrentEntry 9 }
ethIfCurrentSingleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of successfully
transmitted frames for which transmission was inhibited by
exactly one collision, encountered by the Ethernet interface
in the current 15 minute interval."
::= { ethIfCurrentEntry 10 }
ethIfCurrentMultipleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of successfully
transmitted frames for which transmission was inhibited by
more than one collision, encountered by the Ethernet interface
in the current 15 minute interval."
::= { ethIfCurrentEntry 11 }
ethIfCurrentDeferredTransmissions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames
for which the first transmission attempt was delayed due to a
busy media, encountered by the Ethernet interface in the
current 15 minute interval."
::= { ethIfCurrentEntry 12 }
ethIfCurrentLateCollisions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times that a
collision was detected later than the first 64 bytes of the
frame, encountered by the Ethernet interface in the current
15 minute interval."
::= { ethIfCurrentEntry 13 }
ethIfCurrentCarrierSenseErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times that the
carrier sense condition was lost or never asserted when
attempting to transmit a frame, encountered by the Ethernet
interface in the current 15 minute interval."
::= { ethIfCurrentEntry 14 }
ethIfCurrentInputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of frames dropped
due to lack of buffers in ingress pool, encountered by
the Ethernet interface in the current 15 minute interval."
::= { ethIfCurrentEntry 15 }
ethIfCurrentOutputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the Transmit direction
to the Ethernet interface in the current 15 minute interval."
::= { ethIfCurrentEntry 16 }
--Interval Table
ethIfIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Interval table."
::= { ethIfPerformance 2 }
ethIfIntervalEntry OBJECT-TYPE
SYNTAX EthIfIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet Interval table."
INDEX { ethIfIntervalIndex, ethIfIntervalNumber }
::= {ethIfIntervalTable 1}
EthIfIntervalEntry ::=
SEQUENCE {
ethIfIntervalIndex
Integer32,
ethIfIntervalNumber
Integer32,
ethIfIntervalStatus
OCTET STRING,
ethIfIntervalInFrames
Gauge32,
ethIfIntervalInOctets
Gauge32,
ethIfIntervalAlignmentErrors
Gauge32,
ethIfIntervalFCSErrors
Gauge32,
ethIfIntervalLengthError
Gauge32,
ethIfIntervalOutFrames
Gauge32,
ethIfIntervalOutOctets
Gauge32,
ethIfIntervalSingleCollisionFrames
Gauge32,
ethIfIntervalMultipleCollisionFrames
Gauge32,
ethIfIntervalDeferredTransmissions
Gauge32,
ethIfIntervalLateCollisions
Gauge32,
ethIfIntervalCarrierSenseErrors
Gauge32,
ethIfIntervalInputCongestionDropped
Gauge32,
ethIfIntervalOutputCongestionDropped
Gauge32
}
ethIfIntervalIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the Ethernet interface.
It may be ifIndex."
::= { ethIfIntervalEntry 1 }
ethIfIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { ethIfIntervalEntry 2 }
ethIfIntervalStatus OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The statuses of the current interval:
0 - Valid.
1 - redundantLinkSwitch - the link has been switched
by a redundancy mechanism.
2 - discontinuity - module was partialy out.
4 - notValid - module is out."
::= { ethIfIntervalEntry 3 }
ethIfIntervalInFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
encountered by the Ethernet interface in one of the previous
96, individual 15 minute, intervals."
::= { ethIfIntervalEntry 4 }
ethIfIntervalInOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received octets,
encountered by the Ethernet interface in one of the previous
96, individual 15 minute, intervals."
::= { ethIfIntervalEntry 5 }
ethIfIntervalAlignmentErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames,
which are not complete (The result of dividing the number
of bits by 8 is not an Integer), encountered by the Ethernet
interface in one of the previous 96, individual 15 minute,
intervals."
::= { ethIfIntervalEntry 6 }
ethIfIntervalFCSErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
that didn't pass the FCS test, encountered by the Ethernet
interface in one of the previous 96, individual 15 minute,
intervals."
::= { ethIfIntervalEntry 7 }
ethIfIntervalLengthError OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received frames
with length error, encountered by the Ethernet interface in
one of the previous 96, individual 15 minute, intervals."
::= { ethIfIntervalEntry 8 }
ethIfIntervalOutFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames,
encountered by the Ethernet interface in one of the previous
96, individual 15 minute, intervals."
::= { ethIfIntervalEntry 9 }
ethIfIntervalOutOctets OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted octets,
encountered by the Ethernet interface in one of the previous
96, individual 15 minute, intervals."
::= { ethIfIntervalEntry 10 }
ethIfIntervalSingleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of successfully
transmitted frames for which transmission was inhibited by
exactly one collision, encountered by the Ethernet
interface in one of the previous 96, individual 15 minute,
intervals."
::= { ethIfIntervalEntry 11 }
ethIfIntervalMultipleCollisionFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of successfully
transmitted frames for which transmission was inhibited by
more than one collision, encountered by the Ethernet
interface in one of the previous 96, individual 15 minute,
intervals."
::= { ethIfIntervalEntry 12 }
ethIfIntervalDeferredTransmissions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted frames
for which the first transmission attempt was delayed due to a
busy media, encountered by the Ethernet interface in one of
the previous 96, individual 15 minute, intervals."
::= { ethIfIntervalEntry 13 }
ethIfIntervalLateCollisions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times that a
collision was detected later than the first 64 bytes of the
frame, encountered by the Ethernet interface in one of the
previous 96, individual 15 minute, intervals."
::= { ethIfIntervalEntry 14 }
ethIfIntervalCarrierSenseErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of times that the
carrier sense condition was lost or never asserted when
attempting to transmit a frame, encountered by the Ethernet
interface in one of the previous 96, individual 15 minute,
intervals."
::= { ethIfIntervalEntry 15 }
ethIfIntervalInputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the Receive direction
to the Ethernet interface in one of the previous 96, individual
15 minute, intervals."
::= { ethIfIntervalEntry 16 }
ethIfIntervalOutputCongestionDropped OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of dropped frames
due to a congestion, encountered by the Transmit direction
to the Ethernet interface in one of the previous 96, individual
15 minute, intervals."
::= { ethIfIntervalEntry 17 }
ethPerformanceMode OBJECT-TYPE
SYNTAX INTEGER
{
notApplicable (1),
countOK (2),
countFail (3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object indicates whether OK or Fail statistics will be counted."
::= {ethIfPerformance 3}
ethIfPerfTable OBJECT-TYPE
SYNTAX SEQUENCE OF EthIfPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Ethernet Performance table."
::= { ethIfPerformance 4}
ethIfPerfEntry OBJECT-TYPE
SYNTAX EthIfPerfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Ethernet Performance table."
INDEX {ethIfIdx}
::= {ethIfPerfTable 1}
EthIfPerfEntry ::=
SEQUENCE {
ethIfPerfInOkFrames
Gauge32,
ethIfPerfOutOkFrames
Gauge32,
ethIfPerfTotalCollisions
Gauge32
}
ethIfPerfInOkFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of received OK frames,
encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2)
or Reset Statistics was done."
::= { ethIfPerfEntry 1 }
ethIfPerfOutOkFrames OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of transmitted OK frames,
encountered by the Ethernet interface since ethPerformanceMode Set to countOK (2)
or Reset Statistics was done."
::= { ethIfPerfEntry 2 }
ethIfPerfTotalCollisions OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the total number of collisions
of any type encountered by the Ethernet interface since
ethPerformanceMode Set to countOK (2) or Reset Statistics was done"
::= { ethIfPerfEntry 3 }
--
-- file :v:\doc\rdv\mib\ver485\atm\atmCes.txt
--
--
-- File: v:\doc\rdv\mib\ver485\atm\atmCes.txt
-- Date: 17/01/02
-- By: Ilana Schvetz
-- Last Update: 17-Jan-02 By Ilana Schvetz
--
-- AAL1 statistics. An addition to ATMF-CES (ces.mib)
--
atmCes OBJECT IDENTIFIER ::= {radAtm 9}
atmCesPerformance OBJECT IDENTIFIER ::= {atmCes 1 }
atmCesAal1CurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCesAal1CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AAL1 Current table."
::= { atmCesPerformance 1 }
atmCesAal1CurrentEntry OBJECT-TYPE
SYNTAX AtmCesAal1CurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the AAL1 Current table."
INDEX { atmCesAal1CurrentIfIndex }
::= { atmCesAal1CurrentTable 1 }
AtmCesAal1CurrentEntry ::=
SEQUENCE {
atmCesAal1CurrentIfIndex
Integer32,
atmCesAal1CurrentSeqErrors
Gauge32,
atmCesAal1CurrentHdrErrors
Gauge32,
atmCesAal1CurrentPointerReframes
Gauge32,
atmCesAal1CurrentBufUnderflows
Gauge32,
atmCesAal1CurrentBufOverflows
Gauge32
}
atmCesAal1CurrentIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the AAL1 interface.
It may be ifIndex."
::= { atmCesAal1CurrentEntry 1 }
atmCesAal1CurrentSeqErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
cells due to wrong sequence number, encountered
by an AAL1 interface in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 2 }
atmCesAal1CurrentHdrErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
cells due to bad AAL1 header error (including correctable
and uncorrectable CRC, and bad parity), encountered
by an AAL1 interface in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 3 }
atmCesAal1CurrentPointerReframes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of events in
which a SDT pointer isn't where it is expected to be,
and must be reacquired, encountered by an AAL1 interface
in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 4 }
atmCesAal1CurrentBufUnderflows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of buffer
underflow events, encountered by an AAL1 interface
in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 5 }
atmCesAal1CurrentBufOverflows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of buffer
overflow events, encountered by an AAL1 interface
in the current 15 minute interval."
::= { atmCesAal1CurrentEntry 6 }
--Interval Table
atmCesAal1IntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCesAal1IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The AAL1 Interval table."
::= { atmCesPerformance 2 }
atmCesAal1IntervalEntry OBJECT-TYPE
SYNTAX AtmCesAal1IntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the AAL1 Interval table."
INDEX { atmCesAal1IntervalIfIndex, atmCesAal1IntervalNumber }
::= { atmCesAal1IntervalTable 1 }
AtmCesAal1IntervalEntry ::=
SEQUENCE {
atmCesAal1IntervalIfIndex
Integer32,
atmCesAal1IntervalNumber
Integer32,
atmCesAal1IntervalSeqErrors
Gauge32,
atmCesAal1IntervalHdrErrors
Gauge32,
atmCesAal1IntervalPointerReframes
Gauge32,
atmCesAal1IntervalBufUnderflows
Gauge32,
atmCesAal1IntervalBufOverflows
Gauge32
}
atmCesAal1IntervalIfIndex OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The index of the AAL1 interface.
It may be ifIndex."
::= { atmCesAal1IntervalEntry 1 }
atmCesAal1IntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A number between 1 and 96, where 1 is the most
recently completed 15 minute interval and 96 is
the least recently completed 15 minutes interval
(assuming that all 96 intervals exist)."
::= { atmCesAal1IntervalEntry 2 }
atmCesAal1IntervalSeqErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
cells due to wrong sequence number, encountered
by an AAL1 interface in one of the previous 96,
individual 15 minute, intervals."
::= { atmCesAal1IntervalEntry 3 }
atmCesAal1IntervalHdrErrors OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Discarded
cells due to bad AAL1 header error (including correctable
and uncorrectable CRC, plus bad parity), encountered
by an AAL1 interface in one of the previous 96,
individual 15 minute, intervals."
::= { atmCesAal1IntervalEntry 4 }
atmCesAal1IntervalPointerReframes OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of events in
which a SDT pointer isn't where it is expected to be,
and must be reacquired, encountered by an AAL1 interface
in one of the previous 96, individual 15 minute,
intervals."
::= { atmCesAal1IntervalEntry 5 }
atmCesAal1IntervalBufUnderflows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of buffer
underflow events, encountered by an AAL1 interface
in one of the previous 96, individual 15 minute,
intervals."
::= { atmCesAal1IntervalEntry 6 }
atmCesAal1IntervalBufOverflows OBJECT-TYPE
SYNTAX Gauge32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of buffer
overflow events, encountered by an AAL1 interface
in one of the previous 96, individual 15 minute,
intervals."
::= { atmCesAal1IntervalEntry 7 }
-- Extension for CES Configuration Table
atmCesConfiguration OBJECT IDENTIFIER ::= {atmCes 2 }
atmCesXConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmCesXConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of atmfCESConfTable table."
::= { atmCesConfiguration 1 }
atmCesXConfEntry OBJECT-TYPE
SYNTAX AtmCesXConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in atmfCESConfTable.
A new row is created in this table upon each new CES VCC creation."
AUGMENTS { atmfCESConfEntry }
::= { atmCesXConfTable 1 }
AtmCesXConfEntry ::= SEQUENCE {
atmCesXConfCBRMode INTEGER
}
atmCesXConfCBRMode OBJECT-TYPE
SYNTAX INTEGER {
normal (2),
spaced (3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter defines if to use Spaced or Normal CBR.
Normal - TD will be allocated from the policing range (described
in ACE2002 NMS SRS). The PCR is expanded with a constant
value of 30 cell/sec.
Spaced - TD will be allocated from the spacing range (described
in ACE2002 NMS SRS). The PCR and CDVT will be expanded
as described for Normal, and the CES traffic including
the OAM will be spaced out at the TD's PCR.
This mode is used to prevent CDVT violation due to OAM
cell insertion with the CES traffic."
::= { atmCesXConfEntry 1 }
--
-- file :v:\doc\rdv\mib\ver495\atm\atmRou~1.txt
--
--Version: 4.95
--
--First Version Date: 12-Aug-2002
--By: Shay Harari
--File: atmRouter.txt
--
--Last update: 20-Oct-2002
--By: Ilana Schvetz
radAtmRouter OBJECT IDENTIFIER ::= { radAtm 10 }
-- Extension of the ATM Logical IP Subnet Interface Mapping Table
-- ( ipoaLisIfMappingTable from RFC 2320 )
atmIpoaLisIfMappingXTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIpoaLisIfMappingXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table is an extension of a table
from RFC 2320: ipoaLisIfMappingTable -
The ATM Logical IP Subnet Interface Mapping Table."
::= { radAtmRouter 1 }
atmIpoaLisIfMappingXEntry OBJECT-TYPE
SYNTAX AtmIpoaLisIfMappingXEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Conceptual row in ipoaLisIfMappingTable."
AUGMENTS { ipoaLisIfMappingEntry }
::= { atmIpoaLisIfMappingXTable 1 }
AtmIpoaLisIfMappingXEntry ::= SEQUENCE {
atmIpoaLisIfMappingType
INTEGER,
atmIpoaLisIfMappingIPAddress
IpAddress
}
atmIpoaLisIfMappingType OBJECT-TYPE
SYNTAX INTEGER {
notApplicable(1),
static(2),
inAtmArp(3)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object indicates the Mapping Type."
::= { atmIpoaLisIfMappingXEntry 1 }
atmIpoaLisIfMappingIPAddress OBJECT-TYPE
SYNTAX IpAddress
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This parameter is applicable for
atmIpoaLisIfMappingTypeIP=static(2).
This parameter is the IP Address assigned
by the user when applicable."
::= { atmIpoaLisIfMappingXEntry 2 }
radAtmRtrInAtmArpInterval OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time interval (in seconds) between sending of
two InATMARP requests."
::= { radAtmRouter 2 }
radAtmRtrInAtmArpAgingTime OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The time (in seconds) that passes until an
entry is deleted, unless this entry
was previously updated by a new inATMARP
request or response.
This variable value should be greater than
the value of radAtmRtrInAtmArpInterval,
so that the entry won't be deleted before
an InATMARP request was sent."
::= { radAtmRouter 3 }