-- powertek iPoManIII MIB
-- MIB for PWT Products
--
-- { iso org(3) dod(6) internet(1) private(4) enterprises(1) powertek(42610)
-- product(1) pdu(4) pwt(4)
-- ==============================================================================================
---
--- Revision History
---
--- v0.10 14-Feb-2014 ChainLiu/Ingrasys Created
--- v0.11 11-Mar-2014 JimmyYang/Ingrasys Modified
--- v0.12 01-Sep-2014 ChainLiu/Ingrasys Add outlets control
--- v0.13 24-Nov-2014 ChainLiu/Ingrasys Modified
--- v0.14 19-May-2015 ChainLiu/Ingrasys Modified
--- v0.15 12-Aug-2015 ChainLiu Modified
--- v0.16 18-Jul-2016 EthanHsu/FIT, Added total current threshold and residual current trap
--- v0.17 18-Oct-2016 JimmyYang/FIT, Added RCM alarm threshold and modify residual current trap.
--- v0.18 17-May-2017 JimmyYang/FIT, Fixed mail & trap description string length bug.
--- v1.00 31-Jul-2017 CainLiu/FIT, Add the mib id of outlet voltage.
--- v2.00 31-Aug-2017 CainLiu/FIT, Modified the file for 8 Daisy Chain.
--- v2.01 17-Nov-2017 CainLiu/FIT, Add the mibs for load balance.
--- v2.02 25-Jun-2017 JimmyYang/FIT, Add the mibs for external EMD.
--- v2.03 29-Jun-2017 JimmyYang/FIT, Fixd the mibs bug for external EMD/EMD.
--- v2.10 10-Sep-2018 JimmyYang/FIT, Integrate SNMP EMD & EMD board.
--- v2.11 28-Nov-2018 JimmyYang/FIT, Add AC fail/restore trap for ATS.
--- v2.12 20-Jun-2019 JimmyYang/FIT, Add phase[1,2,3] energy clean.
--- v2.13 11-Sep-2020 JimmyYang/FIT, Add inlet's frequency, Add inlet's reactive energy.
--- v2.14 24-Sep-2020 JimmyYang/FIT, Add inlet's reactive power.
-- ==============================================================================================
PWTv1-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
TRAP-TYPE
FROM RFC-1215;
powertek OBJECT IDENTIFIER ::= { enterprises 42610 }
product OBJECT IDENTIFIER ::= { powertek 1 }
pdu OBJECT IDENTIFIER ::= { product 4 }
pwt OBJECT IDENTIFIER ::= { pdu 4 }
pduObjects OBJECT IDENTIFIER ::= { pwt 1 }
pduTraps OBJECT IDENTIFIER ::= { pwt 2 }
pduIdent OBJECT IDENTIFIER ::= { pduObjects 1 }
pduNetwork OBJECT IDENTIFIER ::= { pduObjects 2 }
pduSystem OBJECT IDENTIFIER ::= { pduObjects 3 }
pduSNMP OBJECT IDENTIFIER ::= { pduObjects 4 }
pduEmail OBJECT IDENTIFIER ::= { pduObjects 5 }
pduPwrMonitoring OBJECT IDENTIFIER ::= { pduObjects 6 }
pduEnvMonitoring OBJECT IDENTIFIER ::= { pduObjects 7 }
-- ===========================================================================
--
-- pduIdent
--
-- pdu Identification Group
--
-- ===========================================================================
pduIdentAgentSoftwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The firmware version of the device."
::= { pduIdent 1 }
pduIdentSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A Model of this device."
::= { pduIdent 2 }
pduNetworkTcpip OBJECT IDENTIFIER ::= { pduNetwork 1 }
-- ===========================================================================
--
-- pduNetworkTcpip
--
-- Network Configuration Group of the device.
--
-- ===========================================================================
pduNetworkTcpipDhcpControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable DHCP protocol"
::= { pduNetworkTcpip 1 }
pduNetworkTcpipIpv4 OBJECT IDENTIFIER ::= { pduNetworkTcpip 2 }
-- ===========================================================================
--
-- pduNetworkTcpipIpv4
--
-- Ip address Configuration Group of the device.
--
-- ===========================================================================
pduNetworkTcpipIpv4Address OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ip address that NMS can identify the managed device."
::= { pduNetworkTcpipIpv4 1}
pduNetworkTcpipIpv4Gateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The default gateway that allow device managed through routers."
::= { pduNetworkTcpipIpv4 2}
pduNetworkTcpipIpv4Subnet OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Internet address subnet mask"
::= { pduNetworkTcpipIpv4 3}
pduNetworkTcpipIpv4PrimaryDNS OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Internet address of Primary DNS Server"
::= { pduNetworkTcpipIpv4 4}
pduNetworkTcpipIpv4SecondaryDNS OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Internet address of Secondary DNS"
::= { pduNetworkTcpipIpv4 5}
pduNetworkTcpipIpv6 OBJECT IDENTIFIER ::= { pduNetworkTcpip 3 }
-- ===========================================================================
--
-- pduNetworkTcpipIpv6
--
-- Ip address Configuration Group of the device.
--
-- ===========================================================================
pduNetworkTcpipIpv6Control OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable IPv6 protocol"
::= { pduNetworkTcpipIpv6 1 }
pduNetworkTcpipIpv6AutoConfig OBJECT-TYPE
SYNTAX INTEGER {
auto(1),
manual(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"IPv6 Auto-config or Maual setting"
::= { pduNetworkTcpipIpv6 2 }
pduNetworkTcpipIpv6Address OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ipv6 address that NMS can identify the managed device."
::= { pduNetworkTcpipIpv6 3}
pduNetworkTcpipIpv6Prefix OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The prefix length for ipv6 address."
::= { pduNetworkTcpipIpv6 4}
pduNetworkTcpipIpv6Router OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The default gateway that allow device managed through routers."
::= { pduNetworkTcpipIpv6 5}
pduNetworkTcpipIpv6PrimaryDNS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Internet address of Primary DNS Server"
::= { pduNetworkTcpipIpv6 6}
pduNetworkTcpipIpv6SecondaryDNS OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Internet address of Secondary DNS"
::= { pduNetworkTcpipIpv6 7}
pduNetworkSecurity OBJECT IDENTIFIER ::= { pduNetwork 2 }
-- ===========================================================================
--
-- pduNetworkSecurity
--
-- Network Security Group of the device.
--
-- ===========================================================================
pduNetworkSecurityControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable Network Access Protection"
::= { pduNetworkSecurity 1 }
pduNetworkSecuritySsh OBJECT IDENTIFIER ::= { pduNetworkSecurity 2 }
-- ===========================================================================
--
-- pduNetworkSecuritySsh
--
-- SSH Security Group Group of the device.
--
-- ===========================================================================
pduNetworkSecuritySshControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable SSH Access Protection"
::= { pduNetworkSecuritySsh 1 }
pduNetworkSecuritySshInterval OBJECT-TYPE
SYNTAX INTEGER {
oneMinute(1),
fiveMinutes(2),
tenMinutes(3),
thirtyMinutes(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Detecting Interval of SSH Access Protection"
::= { pduNetworkSecuritySsh 2 }
pduNetworkSecuritySshFailTimes OBJECT-TYPE
SYNTAX INTEGER {
five(1),
ten(2),
twenty(3),
thirty(4),
hundred(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unsuccessful attempts of SSH Access Protection"
::= { pduNetworkSecuritySsh 3 }
pduNetworkSecuritySshBlock OBJECT-TYPE
SYNTAX INTEGER {
fiveMinutes(1),
thirtyMinutes(2),
oneHour(3),
oneDay(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Block Time of SSH Access Protection"
::= { pduNetworkSecuritySsh 4 }
pduNetworkSecuritySnmp OBJECT IDENTIFIER ::= { pduNetworkSecurity 3 }
-- ===========================================================================
--
-- pduNetworkSecuritySnmp
--
-- SNMP Security Group Group of the device.
--
-- ===========================================================================
pduNetworkSecuritySnmpControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable SNMP Access Protection"
::= { pduNetworkSecuritySnmp 1 }
pduNetworkSecuritySnmpInterval OBJECT-TYPE
SYNTAX INTEGER {
oneMinute(1),
fiveMinutes(2),
tenMinutes(3),
thirtyMinutes(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Detecting Interval of SNMP Access Protection"
::= { pduNetworkSecuritySnmp 2 }
pduNetworkSecuritySnmpFailTimes OBJECT-TYPE
SYNTAX INTEGER {
five(1),
ten(2),
twenty(3),
thirty(4),
hundred(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unsuccessful attempts of SNMP Access Protection"
::= { pduNetworkSecuritySnmp 3 }
pduNetworkSecuritySnmpBlock OBJECT-TYPE
SYNTAX INTEGER {
fiveMinutes(1),
thirtyMinutes(2),
oneHour(3),
oneDay(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Block Time of SNMP Access Protection"
::= { pduNetworkSecuritySnmp 4 }
pduNetworkSecurityHttp OBJECT IDENTIFIER ::= { pduNetworkSecurity 4 }
-- ===========================================================================
--
-- pduNetworkSecurityHttp
--
-- HTTP Security Group Group of the device.
--
-- ===========================================================================
pduNetworkSecurityHttpControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable HTTP Access Protection"
::= { pduNetworkSecurityHttp 1 }
pduNetworkSecurityHttpInterval OBJECT-TYPE
SYNTAX INTEGER {
oneMinute(1),
fiveMinutes(2),
tenMinutes(3),
thirtyMinutes(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Detecting Interval of HTTP Access Protection"
::= { pduNetworkSecurityHttp 2 }
pduNetworkSecurityHttpFailTimes OBJECT-TYPE
SYNTAX INTEGER {
five(1),
ten(2),
twenty(3),
thirty(4),
hundred(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unsuccessful attempts of HTTP Access Protection"
::= { pduNetworkSecurityHttp 3 }
pduNetworkSecurityHttpBlock OBJECT-TYPE
SYNTAX INTEGER {
fiveMinutes(1),
thirtyMinutes(2),
oneHour(3),
oneDay(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Block Time of HTTP Access Protection"
::= { pduNetworkSecurityHttp 4 }
pduNetworkService OBJECT IDENTIFIER ::= { pduNetwork 3 }
-- ===========================================================================
--
-- pduNetworkService
--
-- Network Service Group of the device.
--
-- ===========================================================================
pduNetworkServiceSsh OBJECT IDENTIFIER ::= { pduNetworkService 1 }
-- ===========================================================================
--
-- pduNetworkServiceSsh
--
-- SSH Service Group of the device.
--
-- ===========================================================================
pduNetworkServiceSshControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable SSH Server Service"
::= { pduNetworkServiceSsh 1 }
pduNetworkServiceSshPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Port Number of SSH Server Service"
::= { pduNetworkServiceSsh 2 }
pduNetworkServiceSsl OBJECT IDENTIFIER ::= { pduNetworkService 2 }
-- ===========================================================================
--
-- pduNetworkServiceSsl
--
-- HTTPs Service Group of the device.
--
-- ===========================================================================
pduNetworkServiceSslControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable HTTPs Server Service"
::= { pduNetworkServiceSsl 1 }
pduNetworkServiceSslPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Port Number of HTTPs Server Service"
::= { pduNetworkServiceSsl 2 }
pduNetworkServiceSslForce OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force use HTTPs Server Service only."
::= { pduNetworkServiceSsl 3 }
pduNetworkServicePingControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable to response to PING request."
::= { pduNetworkService 3 }
pduNetworkServiceRadius OBJECT IDENTIFIER ::= { pduNetworkService 4 }
-- ===========================================================================
--
-- pduNetworkServiceRadius
--
-- RADIUS Client Service Group of the device.
--
-- ===========================================================================
pduNetworkServiceRadiusControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable RADIUS Client Service"
::= { pduNetworkServiceRadius 1 }
pduNetworkServiceRadiusIp OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Address of RADIUS Client Service"
::= { pduNetworkServiceRadius 2 }
pduNetworkServiceRadiusPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Port Number of RADIUS Client Service"
::= { pduNetworkServiceRadius 3 }
pduNetworkServiceRadiusSecretKey OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Secret Key of RADIUS Client Service"
::= { pduNetworkServiceRadius 4 }
pduNetworkServiceRadiusTimeout OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Timeout Interval of RADIUS Client Service in seconds"
::= { pduNetworkServiceRadius 5 }
pduNetworkServiceRadiusRetry OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Retry Times of RADIUS Client Service"
::= { pduNetworkServiceRadius 6 }
-- ===========================================================================
--
-- pduSystem
--
-- System Management Group of the device.
--
-- ===========================================================================
pduSystemName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of system."
::= { pduSystem 1 }
pduSystemContact OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The contact of system."
::= { pduSystem 2 }
pduSystemLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The location of system."
::= { pduSystem 3 }
pduSystemLogInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Log Interval of device"
::= { pduSystem 4 }
pduSystemWebRefresh OBJECT-TYPE
SYNTAX INTEGER (3..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Web Refresh Interval of device"
::= { pduSystem 5 }
pduSystemTime OBJECT IDENTIFIER ::= { pduSystem 6 }
-- ===========================================================================
--
-- pduSystemTime
--
-- Date/Time Configuration Group of the device.
--
-- ===========================================================================
pduSystemTimeDisplay OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date/time in agent"
::= { pduSystemTime 1 }
pduSystemTimeZone OBJECT-TYPE
SYNTAX INTEGER {
gMT-1200InternationalDateLineWest(1),
gMT-1200Eniwetok-Kwajalein(2),
gMT-1100MidwayIsland-Samoa(3),
gMT-1000Hawaii(4),
gMT-0900Alaska(5),
gMT-0800PacificTime-Tijuana(6),
gMT-0700Arizona-MountainTime(7),
gMT-0700Chihuahua-LaPaz-Mazatlan(8),
gMT-0700MountainTime(9),
gMT-0600CentralAmerica(10),
gMT-0600CentralTime(11),
gMT-0600Guadalajara-MexicoCity-Monterrey(12),
gMT-0600Saskatchewan(13),
gMT-0500Bogota-Lima-Quito(14),
gMT-0500EasternTime(15),
gMT-0500Indiana(16),
gMT-0400AtlanticTime(17),
gMT-0400Caracas-LaPaz(18),
gMT-0400Santiago(19),
gMT-0330Newfoundland(20),
gMT-0300Brasilia(21),
gMT-0300BuenosAires-Georgetown(22),
gMT-0300Greenland(23),
gMT-0200Mid-Atlantic(24),
gMT-0100Azores(25),
gMT-0100CapeVerdeIs(26),
gMT-0000Casablanca-Monrovia(27),
gMT-0000GreenwichMeanTime-Dublin-Edinburgh-Lisbon-London(28),
gMT0100Amsterdam-Berlin-Bern-Rome-Stockholm-Vienna(29),
gMT0100Belgrade-Bratislava-Budapest-Ljubljana-Prague(30),
gMT0100Brussels-Copenhagen-Madrid-Paris(31),
gMT0100Sarajevo-Skopje-Warsaw-Zagreb(32),
gMT0100WestCentralAfrica(33),
gMT0200Athens-Istanbul-Minsk(34),
gMT0200Bucharest(35),
gMT0200Cairo(36),
gMT0200Harare-Pretoria(37),
gMT0200Helsinki-Kyiv-Riga-Sofia-Tallinn-Vilnius(38),
gMT0200Jerusalem(39),
gMT0300Baghdad(40),
gMT0300Kuwait-Riyadh(41),
gMT0300Moscow-StPetersburg-Volgograd(42),
gMT0300Nairobi(43),
gMT0330Tehran(44),
gMT0400AbuDhabi-Muscat(45),
gMT0400Baku-Tbilisi-Yerevan(46),
gMT0430Kabul(47),
gMT0500Ekaterinburg(48),
gMT0500Islamabad-Karachi-Tashkent(49),
gMT0530Bombay-Calcutta(50),
gMT0530Chennai-Kolkata-Mumbai-NewDelhi(51),
gMT0545Kathmandu(52),
gMT0600Almaty-Novosibirsk(53),
gMT0600Astana-Dhaka(54),
gMT0600SriJayawardenepura(55),
gMT0630Rangoon(56),
gMT0700Bangkok-Hanoi-Jakarta(57),
gMT0700Krasnoyarsk(58),
gMT0800Beijing-Chongqing-HongKong-Urumqi(59),
gMT0800Irkutsk-UlaanBataar(60),
gMT0800KualaLumpur-Singapore(61),
gMT0800Perth(62),
gMT0800Taipei(63),
gMT0900Osaka-Sapporo-Tokyo(64),
gMT0900Seoul(65),
gMT0900Yakutsk(66),
gMT0930Adelaide(67),
gMT0930Darwin(68),
gMT1000Brisbane(69),
gMT1000Canberra-Melbourne-Sydney(70),
gMT1000Guam-PortMoresby(71),
gMT1000Hobart(72),
gMT1000Vladivostok(73),
gMT1100Magadan-SolomonIs-NewCaledonia(74),
gMT1200Auckland-Wellington(75),
gMT1200Fiji-Kamchatka-MarshallIs(76),
gMT1300NukuAlofa(77)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time Zone to use when synchronize with NTP server."
::= { pduSystemTime 2 }
pduSystemTimeFormat OBJECT-TYPE
SYNTAX INTEGER {
ddmmyyyy(1),
mmddyyyy(2),
yyyymmdd(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Date Format"
::= { pduSystemTime 3 }
pduSystemTimeSetting OBJECT-TYPE
SYNTAX INTEGER {
twentyFourHrFormat(1),
twelveHrFormat(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Time Setting"
::= { pduSystemTime 4 }
pduSystemTimeDayLightSaving OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable the Day Light Saving when synchronize with NTP server."
::= { pduSystemTime 5 }
pduSystemTimeManual OBJECT IDENTIFIER ::= { pduSystemTime 6 }
-- ===========================================================================
--
-- pduSystemTimeManual
--
-- Manual Time Setting Configuration Group of the device.
--
-- ===========================================================================
pduSystemTimeManualDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (10..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The date in agent, format is (dd/mm/yyyy)"
::= { pduSystemTimeManual 1 }
pduSystemTimeManualTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (8..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time in agent, format is (hh:mm:ss)"
::= { pduSystemTimeManual 2 }
pduSystemTimeNtp OBJECT IDENTIFIER ::= { pduSystemTime 7 }
-- ===========================================================================
--
-- pduSystemTimeNtp
--
-- NTP Configuration Group of the device.
--
-- ===========================================================================
pduSystemTimeNtpControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or disable the agent to synchronize date/time with NTP server."
::= { pduSystemTimeNtp 1 }
pduSystemTimeNtpServer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The ip address of NTP server."
::= { pduSystemTimeNtp 2 }
pduSystemTimeNtpSyncInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Sync Interval with NTP server."
::= { pduSystemTimeNtp 3 }
pduSystemTimeNtpSyncUnit OBJECT-TYPE
SYNTAX INTEGER {
day(1),
month(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Unit of Sync Interval"
::= { pduSystemTimeNtp 4 }
pduSystemResetToDefault OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
reset(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset the parameter of PDU to default."
::= { pduSystem 7 }
pduSystemReboot OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
reboot(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reboot the system of PDU."
::= { pduSystem 8 }
-- ===========================================================================
--
-- pduSNMP
--
-- SNMP Configuration Group of the device.
--
-- ===========================================================================
pduSnmpControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable SNMP protocol."
::= { pduSNMP 1 }
pduSnmpPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The UDP port for SNMP."
::= { pduSNMP 2}
pduSnmpVersion OBJECT-TYPE
SYNTAX INTEGER {
v1(1),
v2(2),
v3(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Set SNMP version."
::= { pduSNMP 3 }
pduSnmpTrapsReceiversTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduSnmpTrapsReceiversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of managers to send traps to. The number of
entries is given by the value of pduSnmpNumTrapReceivers"
::= { pduSNMP 4}
pduSnmpTrapsReceiversEntry OBJECT-TYPE
SYNTAX PduSnmpTrapsReceiversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The managers to send traps to."
INDEX { trapsIndex}
::= { pduSnmpTrapsReceiversTable 1 }
PduSnmpTrapsReceiversEntry ::=
SEQUENCE {
trapsIndex
INTEGER,
trapsReceiverAddr
DisplayString,
receiverEventLevel
INTEGER,
receiverSnmpVer
INTEGER,
receiverDescription
DisplayString
}
trapsIndex OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to a trap receiver entry."
::= { pduSnmpTrapsReceiversEntry 1 }
trapsReceiverAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address of the manager to send a trap to."
::= { pduSnmpTrapsReceiversEntry 2 }
receiverEventLevel OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
warning(2),
informational(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The severity level of traps to be received by this manager."
::= { pduSnmpTrapsReceiversEntry 3 }
receiverSnmpVer OBJECT-TYPE
SYNTAX INTEGER {
v1(1),
v2(2),
v3(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The SNMP Trap version of trap receivers."
::= { pduSnmpTrapsReceiversEntry 4 }
receiverDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of trap receivers"
::= { pduSnmpTrapsReceiversEntry 5 }
-- ===========================================================================
--
-- pduEmail
--
-- Email Configuration Group of the device.
--
-- ===========================================================================
pduEmailServer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The address of Email server."
::= { pduEmail 1 }
pduEmailPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The UDP port for Email Server."
::= { pduEmail 2}
pduEmailSenderEmail OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..63))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The sender's Email address"
::= { pduEmail 3 }
pduEmailPrefix OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The prefix string of mail subject"
::= { pduEmail 4 }
pduEmailAuthControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable SMTP Authentication."
::= { pduEmail 5 }
pduEmailAuthUsername OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user name of SMTP Authentication"
::= { pduEmail 6 }
pduEmailAuthPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The password of SMTP Authentication"
::= { pduEmail 7 }
pduEmailReceiversTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduEmailReceiversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of managers to send email notification to."
::= { pduEmail 8}
pduEmailReceiversEntry OBJECT-TYPE
SYNTAX PduEmailReceiversEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The managers to send email notification to."
INDEX { mailRecvIndex}
::= { pduEmailReceiversTable 1 }
PduEmailReceiversEntry ::=
SEQUENCE {
mailRecvIndex
INTEGER,
mailRecvReceiverAddr
DisplayString,
mailRecvEmailType
INTEGER,
mailRecvEventLevel
INTEGER,
mailRecvDescription
DisplayString
}
mailRecvIndex OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to a email notification receiver entry."
::= { pduEmailReceiversEntry 1 }
mailRecvReceiverAddr OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..63))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Email address of the manager to send a email notification to."
::= { pduEmailReceiversEntry 2 }
mailRecvEmailType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
events(2),
status(3),
both(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Email Type of email notification receivers."
::= { pduEmailReceiversEntry 3 }
mailRecvEventLevel OBJECT-TYPE
SYNTAX INTEGER {
critical(1),
warning(2),
informational(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The severity level of email notification to be received by this manager."
::= { pduEmailReceiversEntry 4 }
mailRecvDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..31))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Description of email notification receivers"
::= { pduEmailReceiversEntry 5 }
pduPwrMonitoringInlet OBJECT IDENTIFIER ::= { pduPwrMonitoring 1 }
-- ===========================================================================
--
-- pduPwrMonitoringInlet
--
-- Inlet Management Group of the device.
--
-- ===========================================================================
pduPwrMonitoringInletNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Inlet."
::= { pduPwrMonitoringInlet 1}
-- ===========================================================================
--
-- pduPwrMonitoringInletStatusTable
--
-- Inlet Status Group
--
-- ===========================================================================
pduPwrMonitoringInletStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringInletStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of Inlet."
::= { pduPwrMonitoringInlet 2}
pduPwrMonitoringInletStatusEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringInletStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of Inlet."
INDEX { inletIndex}
::= { pduPwrMonitoringInletStatusTable 1 }
PduPwrMonitoringInletStatusEntry ::=
SEQUENCE {
inletIndex
INTEGER,
inletPowerAll
INTEGER,
inletResetFrom
DisplayString,
inletEnergy
INTEGER,
inletStatus
INTEGER,
inletCurrPhase1b1
INTEGER,
inletCurrPhase2b1
INTEGER,
inletCurrPhase3b1
INTEGER,
inletCurrPhase1b2
INTEGER,
inletCurrPhase2b2
INTEGER,
inletCurrPhase3b2
INTEGER,
inletCurrPhase1
INTEGER,
inletCurrPhase2
INTEGER,
inletCurrPhase3
INTEGER,
inletVoltPhase1
INTEGER,
inletVoltPhase2
INTEGER,
inletVoltPhase3
INTEGER,
inletPwrFactorPhase1b1
INTEGER,
inletPwrFactorPhase2b1
INTEGER,
inletPwrFactorPhase3b1
INTEGER,
inletPwrFactorPhase1b2
INTEGER,
inletPwrFactorPhase2b2
INTEGER,
inletPwrFactorPhase3b2
INTEGER,
inletPowerPhase1b1
INTEGER,
inletPowerPhase2b1
INTEGER,
inletPowerPhase3b1
INTEGER,
inletPowerPhase1b2
INTEGER,
inletPowerPhase2b2
INTEGER,
inletPowerPhase3b2
INTEGER,
inletPowerPhase1
INTEGER,
inletPowerPhase2
INTEGER,
inletPowerPhase3
INTEGER,
inletStatusPhase1
INTEGER,
inletStatusPhase2
INTEGER,
inletStatusPhase3
INTEGER,
inletAppPowerPhase1b1
INTEGER,
inletAppPowerPhase2b1
INTEGER,
inletAppPowerPhase3b1
INTEGER,
inletAppPowerPhase1b2
INTEGER,
inletAppPowerPhase2b2
INTEGER,
inletAppPowerPhase3b2
INTEGER,
inletAppPowerPhase1
INTEGER,
inletAppPowerPhase2
INTEGER,
inletAppPowerPhase3
INTEGER,
inletAppRcmCurrent
INTEGER,
inletLoadBalance
INTEGER,
inletLoadBalanceStatus
INTEGER,
inletResetFromPhase1
DisplayString,
inletEnergyPhase1
INTEGER,
inletResetFromPhase2
DisplayString,
inletEnergyPhase2
INTEGER,
inletResetFromPhase3
DisplayString,
inletEnergyPhase3
INTEGER,
inletFreqPhase1
INTEGER,
inletFreqPhase2
INTEGER,
inletFreqPhase3
INTEGER,
inletReactiveResetFrom
DisplayString,
inletReactiveEnergy
INTEGER,
inletReactiveResetFromPhase1
DisplayString,
inletReactiveEnergyPhase1
INTEGER,
inletReactiveResetFromPhase2
DisplayString,
inletReactiveEnergyPhase2
INTEGER,
inletReactiveResetFromPhase3
DisplayString,
inletReactiveEnergyPhase3
INTEGER,
inletVarPowerPhase1b1
INTEGER,
inletVarPowerPhase2b1
INTEGER,
inletVarPowerPhase3b1
INTEGER,
inletVarPowerPhase1b2
INTEGER,
inletVarPowerPhase2b2
INTEGER,
inletVarPowerPhase3b2
INTEGER,
inletVarPowerPhase1
INTEGER,
inletVarPowerPhase2
INTEGER,
inletVarPowerPhase3
INTEGER
}
inletIndex OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to Inlet status entry."
::= { pduPwrMonitoringInletStatusEntry 1 }
inletPowerAll OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total power of inlet."
::= { pduPwrMonitoringInletStatusEntry 2 }
inletResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of inlet."
::= { pduPwrMonitoringInletStatusEntry 3 }
inletEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total energy of inlet."
::= { pduPwrMonitoringInletStatusEntry 4 }
inletStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Status of inlet power."
::= { pduPwrMonitoringInletStatusEntry 5 }
inletCurrPhase1b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b1 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 6 }
inletCurrPhase2b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b1 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 7 }
inletCurrPhase3b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b1 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 8 }
inletCurrPhase1b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b2 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 9 }
inletCurrPhase2b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b2 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 10 }
inletCurrPhase3b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b2 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 11 }
inletCurrPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 12 }
inletCurrPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 13 }
inletCurrPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3 current of inlet."
::= { pduPwrMonitoringInletStatusEntry 14 }
inletVoltPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 voltage of inlet."
::= { pduPwrMonitoringInletStatusEntry 15 }
inletVoltPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2 voltage of inlet."
::= { pduPwrMonitoringInletStatusEntry 16 }
inletVoltPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3 voltage of inlet."
::= { pduPwrMonitoringInletStatusEntry 17 }
inletPwrFactorPhase1b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b1 power factor of inlet."
::= { pduPwrMonitoringInletStatusEntry 18 }
inletPwrFactorPhase2b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b1 power factor of inlet."
::= { pduPwrMonitoringInletStatusEntry 19 }
inletPwrFactorPhase3b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b1 power factor of inlet."
::= { pduPwrMonitoringInletStatusEntry 20 }
inletPwrFactorPhase1b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b2 power factor of inlet."
::= { pduPwrMonitoringInletStatusEntry 21 }
inletPwrFactorPhase2b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b2 power factor of inlet."
::= { pduPwrMonitoringInletStatusEntry 22 }
inletPwrFactorPhase3b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b2 power factor of inlet."
::= { pduPwrMonitoringInletStatusEntry 23 }
inletPowerPhase1b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b1 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 24 }
inletPowerPhase2b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b1 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 25 }
inletPowerPhase3b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b1 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 26 }
inletPowerPhase1b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b2 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 27 }
inletPowerPhase2b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b2 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 28 }
inletPowerPhase3b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b2 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 29 }
inletPowerPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 30 }
inletPowerPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 31 }
inletPowerPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3 active power of inlet."
::= { pduPwrMonitoringInletStatusEntry 32 }
inletStatusPhase1 OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 status of inlet."
::= { pduPwrMonitoringInletStatusEntry 33 }
inletStatusPhase2 OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2 status of inlet."
::= { pduPwrMonitoringInletStatusEntry 34 }
inletStatusPhase3 OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3 status of inlet."
::= { pduPwrMonitoringInletStatusEntry 35 }
inletAppPowerPhase1b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b1 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 36 }
inletAppPowerPhase2b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b1 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 37 }
inletAppPowerPhase3b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b1 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 38 }
inletAppPowerPhase1b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b2 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 39 }
inletAppPowerPhase2b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b2 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 40 }
inletAppPowerPhase3b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b2 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 41 }
inletAppPowerPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 42 }
inletAppPowerPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 43 }
inletAppPowerPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3 apparent power of inlet."
::= { pduPwrMonitoringInletStatusEntry 44 }
inletAppRcmCurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1mA"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The RCM leackage current of inlet."
::= { pduPwrMonitoringInletStatusEntry 45 }
inletLoadBalance OBJECT-TYPE
SYNTAX INTEGER
UNITS "1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The load balance of inlet."
::= { pduPwrMonitoringInletStatusEntry 46 }
inletLoadBalanceStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The load balance of status inlet."
::= { pduPwrMonitoringInletStatusEntry 47 }
inletResetFromPhase1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset phase1 date of inlet."
::= { pduPwrMonitoringInletStatusEntry 48 }
inletEnergyPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 energy of inlet."
::= { pduPwrMonitoringInletStatusEntry 49 }
inletResetFromPhase2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset phase2 date of inlet."
::= { pduPwrMonitoringInletStatusEntry 50 }
inletEnergyPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2 energy of inlet."
::= { pduPwrMonitoringInletStatusEntry 51 }
inletResetFromPhase3 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset phase3 date of inlet."
::= { pduPwrMonitoringInletStatusEntry 52 }
inletEnergyPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3 energy of inlet."
::= { pduPwrMonitoringInletStatusEntry 53 }
inletFreqPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01HZ"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 frequency of inlet."
::= { pduPwrMonitoringInletStatusEntry 54 }
inletFreqPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01HZ"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2 frequency of inlet."
::= { pduPwrMonitoringInletStatusEntry 55 }
inletFreqPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01HZ"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3 frequency of inlet."
::= { pduPwrMonitoringInletStatusEntry 56 }
inletReactiveResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset reactive date of inlet."
::= { pduPwrMonitoringInletStatusEntry 57 }
inletReactiveEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total reactive energy of inlet."
::= { pduPwrMonitoringInletStatusEntry 58 }
inletReactiveResetFromPhase1 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset phase1 reactive date of inlet."
::= { pduPwrMonitoringInletStatusEntry 59 }
inletReactiveEnergyPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 reactive energy of inlet."
::= { pduPwrMonitoringInletStatusEntry 60 }
inletReactiveResetFromPhase2 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset phase1 reactive date of inlet."
::= { pduPwrMonitoringInletStatusEntry 61 }
inletReactiveEnergyPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 reactive energy of inlet."
::= { pduPwrMonitoringInletStatusEntry 62 }
inletReactiveResetFromPhase3 OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset phase1 reactive date of inlet."
::= { pduPwrMonitoringInletStatusEntry 63 }
inletReactiveEnergyPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 reactive energy of inlet."
::= { pduPwrMonitoringInletStatusEntry 64 }
inletVarPowerPhase1b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b1 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 65 }
inletVarPowerPhase2b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b1 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 66 }
inletVarPowerPhase3b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b1 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 67 }
inletVarPowerPhase1b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1b2 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 68 }
inletVarPowerPhase2b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2b2 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 69 }
inletVarPowerPhase3b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3b2 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 70 }
inletVarPowerPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase1 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 71 }
inletVarPowerPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase2 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 72 }
inletVarPowerPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The phase3 reactive power of inlet."
::= { pduPwrMonitoringInletStatusEntry 73 }
-- ===========================================================================
--
-- pduPwrMonitoringInletCfgTable
--
-- Inlet Configuration Group
--
-- ===========================================================================
pduPwrMonitoringInletCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringInletCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to configure thresholds of inlet."
::= { pduPwrMonitoringInlet 3}
pduPwrMonitoringInletCfgEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringInletCfgEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to configure thresholds of inlet."
INDEX { inletCfgIndex}
::= { pduPwrMonitoringInletCfgTable 1 }
PduPwrMonitoringInletCfgEntry ::=
SEQUENCE {
inletCfgIndex
INTEGER,
inletCfgLoadCritical
INTEGER,
inletCfgLoadWarning
INTEGER,
inletCfgCurrCritPhase1b1
INTEGER,
inletCfgCurrCritPhase2b1
INTEGER,
inletCfgCurrCritPhase3b1
INTEGER,
inletCfgCurrCritPhase1b2
INTEGER,
inletCfgCurrCritPhase2b2
INTEGER,
inletCfgCurrCritPhase3b2
INTEGER,
inletCfgCurrWarnPhase1b1
INTEGER,
inletCfgCurrWarnPhase2b1
INTEGER,
inletCfgCurrWarnPhase3b1
INTEGER,
inletCfgCurrWarnPhase1b2
INTEGER,
inletCfgCurrWarnPhase2b2
INTEGER,
inletCfgCurrWarnPhase3b2
INTEGER,
inletCfgVoltCritPhase1
INTEGER,
inletCfgVoltCritPhase2
INTEGER,
inletCfgVoltCritPhase3
INTEGER,
inletCfgVoltWarnPhase1
INTEGER,
inletCfgVoltWarnPhase2
INTEGER,
inletCfgVoltWarnPhase3
INTEGER,
inletCfgTotalCurrCritPhase1
INTEGER,
inletCfgTotalCurrCritPhase2
INTEGER,
inletCfgTotalCurrCritPhase3
INTEGER,
inletCfgTotalCurrWarnPhase1
INTEGER,
inletCfgTotalCurrWarnPhase2
INTEGER,
inletCfgTotalCurrWarnPhase3
INTEGER,
inletCfgRcmCurrThreshold
INTEGER,
inletCfgLoadBalanceCrit
INTEGER,
inletCfgLoadBalanceWarn
INTEGER
}
inletCfgIndex OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to inlet configuration entry."
::= { pduPwrMonitoringInletCfgEntry 1 }
inletCfgLoadCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1kW"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of inlet load."
::= { pduPwrMonitoringInletCfgEntry 2 }
inletCfgLoadWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1kW"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of inlet load."
::= { pduPwrMonitoringInletCfgEntry 3 }
inletCfgCurrCritPhase1b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse1b1 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 4 }
inletCfgCurrCritPhase2b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse2b1 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 5 }
inletCfgCurrCritPhase3b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse3b1 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 6 }
inletCfgCurrCritPhase1b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse1b2 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 7 }
inletCfgCurrCritPhase2b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse2b2 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 8 }
inletCfgCurrCritPhase3b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse3b2 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 9 }
inletCfgCurrWarnPhase1b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse1b1 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 10 }
inletCfgCurrWarnPhase2b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse2b1 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 11 }
inletCfgCurrWarnPhase3b1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse3b1 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 12 }
inletCfgCurrWarnPhase1b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse1b2 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 13 }
inletCfgCurrWarnPhase2b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse2b2 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 14 }
inletCfgCurrWarnPhase3b2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse3b2 current of inlet."
::= { pduPwrMonitoringInletCfgEntry 15 }
inletCfgVoltCritPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse1 voltage of inlet."
::= { pduPwrMonitoringInletCfgEntry 16 }
inletCfgVoltCritPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse2 voltage of inlet."
::= { pduPwrMonitoringInletCfgEntry 17 }
inletCfgVoltCritPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse3 voltage of inlet."
::= { pduPwrMonitoringInletCfgEntry 18 }
inletCfgVoltWarnPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse1 voltage of inlet."
::= { pduPwrMonitoringInletCfgEntry 19 }
inletCfgVoltWarnPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse2 voltage of inlet."
::= { pduPwrMonitoringInletCfgEntry 20 }
inletCfgVoltWarnPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse3 voltage of inlet."
::= { pduPwrMonitoringInletCfgEntry 21 }
inletCfgTotalCurrCritPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse1 total current of inlet."
::= { pduPwrMonitoringInletCfgEntry 22 }
inletCfgTotalCurrCritPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse2 total current of inlet."
::= { pduPwrMonitoringInletCfgEntry 23 }
inletCfgTotalCurrCritPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of pahse3 total current of inlet."
::= { pduPwrMonitoringInletCfgEntry 24 }
inletCfgTotalCurrWarnPhase1 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse1 total current of inlet."
::= { pduPwrMonitoringInletCfgEntry 25 }
inletCfgTotalCurrWarnPhase2 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse2 total current of inlet."
::= { pduPwrMonitoringInletCfgEntry 26 }
inletCfgTotalCurrWarnPhase3 OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of pahse3 total current of inlet."
::= { pduPwrMonitoringInletCfgEntry 27 }
inletCfgRcmCurrThreshold OBJECT-TYPE
SYNTAX INTEGER
UNITS "1mA"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The RCM Alarm threshold of inlet."
::= { pduPwrMonitoringInletCfgEntry 28 }
inletCfgLoadBalanceCrit OBJECT-TYPE
SYNTAX INTEGER
UNITS "1%"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of load balance of inlet."
::= { pduPwrMonitoringInletCfgEntry 29 }
inletCfgLoadBalanceWarn OBJECT-TYPE
SYNTAX INTEGER
UNITS "1%"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of load balance of inlet."
::= { pduPwrMonitoringInletCfgEntry 30 }
pduPwrMonitoringOutlet OBJECT IDENTIFIER ::= { pduPwrMonitoring 2 }
-- ===========================================================================
--
-- pduPwrMonitoringOutlet
--
-- Outlet Management Group of the device.
--
-- ===========================================================================
pduPwrMonitoringOutletPduA OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 1 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduA
--
-- Outlet of Device1 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduA OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PduA Outlet."
::= { pduPwrMonitoringOutletPduA 1}
-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduA
--
-- Outlet of Device1 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduA OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduAEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduA outlet."
::= { pduPwrMonitoringOutletPduA 2}
pduPwrMonitoringOutletStatusPduAEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletStatusPduAEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduA outlet."
INDEX { outletPduAIndex}
::= { pduPwrMonitoringOutletStatusTablePduA 1 }
PduPwrMonitoringOutletStatusPduAEntry ::=
SEQUENCE {
outletPduAIndex
INTEGER,
outletPduAState
INTEGER,
outletPduACurrent
INTEGER,
outletPduAPwrFactor
INTEGER,
outletPduAPower
INTEGER,
outletPduAEnergy
INTEGER,
outletPduAResetFrom
DisplayString,
outletPduAStatus
INTEGER,
outletPduAAppPower
INTEGER,
outletPduAVoltage
INTEGER
}
outletPduAIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet status of PduA."
::= { pduPwrMonitoringOutletStatusPduAEntry 1 }
outletPduAState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 2 }
outletPduACurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 3 }
outletPduAPwrFactor OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power factor of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 4 }
outletPduAPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The active power of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 5 }
outletPduAEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The energy of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 6 }
outletPduAResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 7 }
outletPduAStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 8 }
outletPduAAppPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The apparent power of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 9 }
outletPduAVoltage OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of PduA outlet."
::= { pduPwrMonitoringOutletStatusPduAEntry 10 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduA
--
-- Outlet of Device1 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduA OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduAEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduA outlet."
::= { pduPwrMonitoringOutletPduA 3}
pduPwrMonitoringOutletCfgPduAEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCfgPduAEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduA outlet."
INDEX { outletCfgPduAIndex}
::= { pduPwrMonitoringOutletCfgTablePduA 1 }
PduPwrMonitoringOutletCfgPduAEntry ::=
SEQUENCE {
outletCfgPduAIndex
INTEGER,
outletCfgPduAName
DisplayString,
outletCfgPduADelayOnStatus
INTEGER,
outletCfgPduADelayOnTime
INTEGER,
outletCfgPduADelayOffStatus
INTEGER,
outletCfgPduADelayOffTime
INTEGER,
outletCfgPduAReboot
INTEGER,
outletCfgPduAOverCurrCritical
INTEGER,
outletCfgPduAOverCurrWarning
INTEGER,
outletCfgPduAOverPwrCritical
INTEGER,
outletCfgPduAOverPwrWarning
INTEGER
}
outletCfgPduAIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet configuration of PduA."
::= { pduPwrMonitoringOutletCfgPduAEntry 1 }
outletCfgPduAName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name for outlet of PduA."
::= { pduPwrMonitoringOutletCfgPduAEntry 2 }
outletCfgPduADelayOnStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On status of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 3 }
outletCfgPduADelayOnTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On time of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 4 }
outletCfgPduADelayOffStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off status of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 5 }
outletCfgPduADelayOffTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off time of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 6 }
outletCfgPduAReboot OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On reboot duration of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 7 }
outletCfgPduAOverCurrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of current of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 8 }
outletCfgPduAOverCurrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of current of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 9 }
outletCfgPduAOverPwrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of power of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 10 }
outletCfgPduAOverPwrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of power of PduA outlet."
::= { pduPwrMonitoringOutletCfgPduAEntry 11 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduA
--
-- Outlet of Device1 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduA OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduAEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduA outlet."
::= { pduPwrMonitoringOutletPduA 4}
pduPwrMonitoringOutletCtlPduAEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCtlPduAEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduA outlet."
INDEX { outletCtlPduAIndex}
::= { pduPwrMonitoringOutletCtlTablePduA 1 }
PduPwrMonitoringOutletCtlPduAEntry ::=
SEQUENCE {
outletCtlPduAIndex
INTEGER,
outletCtlPduAControl
INTEGER
}
outletCtlPduAIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet control of PduA."
::= { pduPwrMonitoringOutletCtlPduAEntry 1 }
outletCtlPduAControl OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
immediateOn(2),
delayedOn(3),
immediateOff(4),
delayedOff(5),
immediateCycle(6),
delayedCycle(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control-type of PduA outlet."
::= { pduPwrMonitoringOutletCtlPduAEntry 2 }
pduPwrMonitoringOutletPduB OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 2 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduB
--
-- Outlet of Device2 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduB OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PduB Outlet."
::= { pduPwrMonitoringOutletPduB 1}
-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduB
--
-- Outlet of Device2 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduB OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduBEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduB outlet."
::= { pduPwrMonitoringOutletPduB 2}
pduPwrMonitoringOutletStatusPduBEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletStatusPduBEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduB outlet."
INDEX { outletPduBIndex}
::= { pduPwrMonitoringOutletStatusTablePduB 1 }
PduPwrMonitoringOutletStatusPduBEntry ::=
SEQUENCE {
outletPduBIndex
INTEGER,
outletPduBState
INTEGER,
outletPduBCurrent
INTEGER,
outletPduBPwrFactor
INTEGER,
outletPduBPower
INTEGER,
outletPduBEnergy
INTEGER,
outletPduBResetFrom
DisplayString,
outletPduBStatus
INTEGER,
outletPduBAppPower
INTEGER,
outletPduBVoltage
INTEGER
}
outletPduBIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet status of PduB."
::= { pduPwrMonitoringOutletStatusPduBEntry 1 }
outletPduBState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 2 }
outletPduBCurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 3 }
outletPduBPwrFactor OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power factor of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 4 }
outletPduBPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The active power of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 5 }
outletPduBEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The energy of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 6 }
outletPduBResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 7 }
outletPduBStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 8 }
outletPduBAppPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The apparent power of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 9 }
outletPduBVoltage OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of PduB outlet."
::= { pduPwrMonitoringOutletStatusPduBEntry 10 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduB
--
-- Outlet of Device2 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduB OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduBEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduB outlet."
::= { pduPwrMonitoringOutletPduB 3}
pduPwrMonitoringOutletCfgPduBEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCfgPduBEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduB outlet."
INDEX { outletCfgPduBIndex}
::= { pduPwrMonitoringOutletCfgTablePduB 1 }
PduPwrMonitoringOutletCfgPduBEntry ::=
SEQUENCE {
outletCfgPduBIndex
INTEGER,
outletCfgPduBName
DisplayString,
outletCfgPduBDelayOnStatus
INTEGER,
outletCfgPduBDelayOnTime
INTEGER,
outletCfgPduBDelayOffStatus
INTEGER,
outletCfgPduBDelayOffTime
INTEGER,
outletCfgPduBReboot
INTEGER,
outletCfgPduBOverCurrCritical
INTEGER,
outletCfgPduBOverCurrWarning
INTEGER,
outletCfgPduBOverPwrCritical
INTEGER,
outletCfgPduBOverPwrWarning
INTEGER
}
outletCfgPduBIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet configuration of PduB."
::= { pduPwrMonitoringOutletCfgPduBEntry 1 }
outletCfgPduBName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name for outlet of PduB."
::= { pduPwrMonitoringOutletCfgPduBEntry 2 }
outletCfgPduBDelayOnStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On status of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 3 }
outletCfgPduBDelayOnTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On time of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 4 }
outletCfgPduBDelayOffStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off status of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 5 }
outletCfgPduBDelayOffTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off time of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 6 }
outletCfgPduBReboot OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On reboot duration of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 7 }
outletCfgPduBOverCurrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of current of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 8 }
outletCfgPduBOverCurrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of current of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 9 }
outletCfgPduBOverPwrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of power of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 10 }
outletCfgPduBOverPwrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of power of PduB outlet."
::= { pduPwrMonitoringOutletCfgPduBEntry 11 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduB
--
-- Outlet of Device2 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduB OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduBEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduB outlet."
::= { pduPwrMonitoringOutletPduB 4}
pduPwrMonitoringOutletCtlPduBEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCtlPduBEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduB outlet."
INDEX { outletCtlPduBIndex}
::= { pduPwrMonitoringOutletCtlTablePduB 1 }
PduPwrMonitoringOutletCtlPduBEntry ::=
SEQUENCE {
outletCtlPduBIndex
INTEGER,
outletCtlPduBControl
INTEGER
}
outletCtlPduBIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet control of PduB."
::= { pduPwrMonitoringOutletCtlPduBEntry 1 }
outletCtlPduBControl OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
immediateOn(2),
delayedOn(3),
immediateOff(4),
delayedOff(5),
immediateCycle(6),
delayedCycle(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control-type of PduB outlet."
::= { pduPwrMonitoringOutletCtlPduBEntry 2 }
pduPwrMonitoringOutletPduC OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 3 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduC
--
-- Outlet of Device3 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PduC Outlet."
::= { pduPwrMonitoringOutletPduC 1}
-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduC
--
-- Outlet of Device3 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduC OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduC outlet."
::= { pduPwrMonitoringOutletPduC 2}
pduPwrMonitoringOutletStatusPduCEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletStatusPduCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduC outlet."
INDEX { outletPduCIndex}
::= { pduPwrMonitoringOutletStatusTablePduC 1 }
PduPwrMonitoringOutletStatusPduCEntry ::=
SEQUENCE {
outletPduCIndex
INTEGER,
outletPduCState
INTEGER,
outletPduCCurrent
INTEGER,
outletPduCPwrFactor
INTEGER,
outletPduCPower
INTEGER,
outletPduCEnergy
INTEGER,
outletPduCResetFrom
DisplayString,
outletPduCStatus
INTEGER,
outletPduCAppPower
INTEGER,
outletPduCVoltage
INTEGER
}
outletPduCIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet status of PduC."
::= { pduPwrMonitoringOutletStatusPduCEntry 1 }
outletPduCState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 2 }
outletPduCCurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 3 }
outletPduCPwrFactor OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power factor of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 4 }
outletPduCPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The active power of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 5 }
outletPduCEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The energy of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 6 }
outletPduCResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 7 }
outletPduCStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 8 }
outletPduCAppPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The apparent power of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 9 }
outletPduCVoltage OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of PduC outlet."
::= { pduPwrMonitoringOutletStatusPduCEntry 10 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduC
--
-- Outlet of Device3 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduC OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduC outlet."
::= { pduPwrMonitoringOutletPduC 3}
pduPwrMonitoringOutletCfgPduCEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCfgPduCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduC outlet."
INDEX { outletCfgPduCIndex}
::= { pduPwrMonitoringOutletCfgTablePduC 1 }
PduPwrMonitoringOutletCfgPduCEntry ::=
SEQUENCE {
outletCfgPduCIndex
INTEGER,
outletCfgPduCName
DisplayString,
outletCfgPduCDelayOnStatus
INTEGER,
outletCfgPduCDelayOnTime
INTEGER,
outletCfgPduCDelayOffStatus
INTEGER,
outletCfgPduCDelayOffTime
INTEGER,
outletCfgPduCReboot
INTEGER,
outletCfgPduCOverCurrCritical
INTEGER,
outletCfgPduCOverCurrWarning
INTEGER,
outletCfgPduCOverPwrCritical
INTEGER,
outletCfgPduCOverPwrWarning
INTEGER
}
outletCfgPduCIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet configuration of PduC."
::= { pduPwrMonitoringOutletCfgPduCEntry 1 }
outletCfgPduCName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name for outlet of PduC."
::= { pduPwrMonitoringOutletCfgPduCEntry 2 }
outletCfgPduCDelayOnStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On status of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 3 }
outletCfgPduCDelayOnTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On time of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 4 }
outletCfgPduCDelayOffStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off status of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 5 }
outletCfgPduCDelayOffTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off time of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 6 }
outletCfgPduCReboot OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On reboot duration of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 7 }
outletCfgPduCOverCurrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of current of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 8 }
outletCfgPduCOverCurrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of current of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 9 }
outletCfgPduCOverPwrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of power of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 10 }
outletCfgPduCOverPwrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of power of PduC outlet."
::= { pduPwrMonitoringOutletCfgPduCEntry 11 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduC
--
-- Outlet of Device3 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduC OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduC outlet."
::= { pduPwrMonitoringOutletPduC 4}
pduPwrMonitoringOutletCtlPduCEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCtlPduCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduC outlet."
INDEX { outletCtlPduCIndex}
::= { pduPwrMonitoringOutletCtlTablePduC 1 }
PduPwrMonitoringOutletCtlPduCEntry ::=
SEQUENCE {
outletCtlPduCIndex
INTEGER,
outletCtlPduCControl
INTEGER
}
outletCtlPduCIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet control of PduC."
::= { pduPwrMonitoringOutletCtlPduCEntry 1 }
outletCtlPduCControl OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
immediateOn(2),
delayedOn(3),
immediateOff(4),
delayedOff(5),
immediateCycle(6),
delayedCycle(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control-type of PduC outlet."
::= { pduPwrMonitoringOutletCtlPduCEntry 2 }
pduPwrMonitoringOutletPduD OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 4 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduD
--
-- Outlet of Device4 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduD OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PduD Outlet."
::= { pduPwrMonitoringOutletPduD 1}
-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduD
--
-- Outlet of Device4 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduD OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduD outlet."
::= { pduPwrMonitoringOutletPduD 2}
pduPwrMonitoringOutletStatusPduDEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletStatusPduDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduD outlet."
INDEX { outletPduDIndex}
::= { pduPwrMonitoringOutletStatusTablePduD 1 }
PduPwrMonitoringOutletStatusPduDEntry ::=
SEQUENCE {
outletPduDIndex
INTEGER,
outletPduDState
INTEGER,
outletPduDCurrent
INTEGER,
outletPduDPwrFactor
INTEGER,
outletPduDPower
INTEGER,
outletPduDEnergy
INTEGER,
outletPduDResetFrom
DisplayString,
outletPduDStatus
INTEGER,
outletPduDAppPower
INTEGER,
outletPduDVoltage
INTEGER
}
outletPduDIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet status of PduD."
::= { pduPwrMonitoringOutletStatusPduDEntry 1 }
outletPduDState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 2 }
outletPduDCurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 3 }
outletPduDPwrFactor OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power factor of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 4 }
outletPduDPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The active power of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 5 }
outletPduDEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The energy of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 6 }
outletPduDResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 7 }
outletPduDStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 8 }
outletPduDAppPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The apparent power of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 9 }
outletPduDVoltage OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of PduD outlet."
::= { pduPwrMonitoringOutletStatusPduDEntry 10 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduD
--
-- Outlet of Device4 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduD OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduD outlet."
::= { pduPwrMonitoringOutletPduD 3}
pduPwrMonitoringOutletCfgPduDEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCfgPduDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduD outlet."
INDEX { outletCfgPduDIndex}
::= { pduPwrMonitoringOutletCfgTablePduD 1 }
PduPwrMonitoringOutletCfgPduDEntry ::=
SEQUENCE {
outletCfgPduDIndex
INTEGER,
outletCfgPduDName
DisplayString,
outletCfgPduDDelayOnStatus
INTEGER,
outletCfgPduDDelayOnTime
INTEGER,
outletCfgPduDDelayOffStatus
INTEGER,
outletCfgPduDDelayOffTime
INTEGER,
outletCfgPduDReboot
INTEGER,
outletCfgPduDOverCurrCritical
INTEGER,
outletCfgPduDOverCurrWarning
INTEGER,
outletCfgPduDOverPwrCritical
INTEGER,
outletCfgPduDOverPwrWarning
INTEGER
}
outletCfgPduDIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet configuration of PduD."
::= { pduPwrMonitoringOutletCfgPduDEntry 1 }
outletCfgPduDName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name for outlet of PduD."
::= { pduPwrMonitoringOutletCfgPduDEntry 2 }
outletCfgPduDDelayOnStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On status of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 3 }
outletCfgPduDDelayOnTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On time of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 4 }
outletCfgPduDDelayOffStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off status of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 5 }
outletCfgPduDDelayOffTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off time of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 6 }
outletCfgPduDReboot OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On reboot duration of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 7 }
outletCfgPduDOverCurrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of current of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 8 }
outletCfgPduDOverCurrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of current of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 9 }
outletCfgPduDOverPwrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of power of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 10 }
outletCfgPduDOverPwrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of power of PduD outlet."
::= { pduPwrMonitoringOutletCfgPduDEntry 11 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduD
--
-- Outlet of Device4 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduD OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduD outlet."
::= { pduPwrMonitoringOutletPduD 4}
pduPwrMonitoringOutletCtlPduDEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCtlPduDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduD outlet."
INDEX { outletCtlPduDIndex}
::= { pduPwrMonitoringOutletCtlTablePduD 1 }
PduPwrMonitoringOutletCtlPduDEntry ::=
SEQUENCE {
outletCtlPduDIndex
INTEGER,
outletCtlPduDControl
INTEGER
}
outletCtlPduDIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet control of PduD."
::= { pduPwrMonitoringOutletCtlPduDEntry 1 }
outletCtlPduDControl OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
immediateOn(2),
delayedOn(3),
immediateOff(4),
delayedOff(5),
immediateCycle(6),
delayedCycle(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control-type of PduD outlet."
::= { pduPwrMonitoringOutletCtlPduDEntry 2 }
pduPwrMonitoringOutletPduE OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 5 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduE
--
-- Outlet of Device5 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduE OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PduE Outlet."
::= { pduPwrMonitoringOutletPduE 1}
-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduE
--
-- Outlet of Device5 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduE OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduEEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduE outlet."
::= { pduPwrMonitoringOutletPduE 2}
pduPwrMonitoringOutletStatusPduEEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletStatusPduEEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduE outlet."
INDEX { outletPduEIndex}
::= { pduPwrMonitoringOutletStatusTablePduE 1 }
PduPwrMonitoringOutletStatusPduEEntry ::=
SEQUENCE {
outletPduEIndex
INTEGER,
outletPduEState
INTEGER,
outletPduECurrent
INTEGER,
outletPduEPwrFactor
INTEGER,
outletPduEPower
INTEGER,
outletPduEEnergy
INTEGER,
outletPduEResetFrom
DisplayString,
outletPduEStatus
INTEGER,
outletPduEAppPower
INTEGER,
outletPduEVoltage
INTEGER
}
outletPduEIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet status of PduE."
::= { pduPwrMonitoringOutletStatusPduEEntry 1 }
outletPduEState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 2 }
outletPduECurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 3 }
outletPduEPwrFactor OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power factor of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 4 }
outletPduEPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The active power of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 5 }
outletPduEEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The energy of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 6 }
outletPduEResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 7 }
outletPduEStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 8 }
outletPduEAppPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The apparent power of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 9 }
outletPduEVoltage OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of PduE outlet."
::= { pduPwrMonitoringOutletStatusPduEEntry 10 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduE
--
-- Outlet of Device5 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduE OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduEEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduE outlet."
::= { pduPwrMonitoringOutletPduE 3}
pduPwrMonitoringOutletCfgPduEEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCfgPduEEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduE outlet."
INDEX { outletCfgPduEIndex}
::= { pduPwrMonitoringOutletCfgTablePduE 1 }
PduPwrMonitoringOutletCfgPduEEntry ::=
SEQUENCE {
outletCfgPduEIndex
INTEGER,
outletCfgPduEName
DisplayString,
outletCfgPduEDelayOnStatus
INTEGER,
outletCfgPduEDelayOnTime
INTEGER,
outletCfgPduEDelayOffStatus
INTEGER,
outletCfgPduEDelayOffTime
INTEGER,
outletCfgPduEReboot
INTEGER,
outletCfgPduEOverCurrCritical
INTEGER,
outletCfgPduEOverCurrWarning
INTEGER,
outletCfgPduEOverPwrCritical
INTEGER,
outletCfgPduEOverPwrWarning
INTEGER
}
outletCfgPduEIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet configuration of PduE."
::= { pduPwrMonitoringOutletCfgPduEEntry 1 }
outletCfgPduEName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name for outlet of PduE."
::= { pduPwrMonitoringOutletCfgPduEEntry 2 }
outletCfgPduEDelayOnStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On status of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 3 }
outletCfgPduEDelayOnTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On time of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 4 }
outletCfgPduEDelayOffStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off status of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 5 }
outletCfgPduEDelayOffTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off time of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 6 }
outletCfgPduEReboot OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On reboot duration of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 7 }
outletCfgPduEOverCurrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of current of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 8 }
outletCfgPduEOverCurrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of current of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 9 }
outletCfgPduEOverPwrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of power of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 10 }
outletCfgPduEOverPwrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of power of PduE outlet."
::= { pduPwrMonitoringOutletCfgPduEEntry 11 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduE
--
-- Outlet of Device5 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduE OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduEEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduE outlet."
::= { pduPwrMonitoringOutletPduE 4}
pduPwrMonitoringOutletCtlPduEEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCtlPduEEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduE outlet."
INDEX { outletCtlPduEIndex}
::= { pduPwrMonitoringOutletCtlTablePduE 1 }
PduPwrMonitoringOutletCtlPduEEntry ::=
SEQUENCE {
outletCtlPduEIndex
INTEGER,
outletCtlPduEControl
INTEGER
}
outletCtlPduEIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet control of PduE."
::= { pduPwrMonitoringOutletCtlPduEEntry 1 }
outletCtlPduEControl OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
immediateOn(2),
delayedOn(3),
immediateOff(4),
delayedOff(5),
immediateCycle(6),
delayedCycle(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control-type of PduE outlet."
::= { pduPwrMonitoringOutletCtlPduEEntry 2 }
pduPwrMonitoringOutletPduF OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 6 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduF
--
-- Outlet of Device6 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduF OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PduF Outlet."
::= { pduPwrMonitoringOutletPduF 1}
-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduF
--
-- Outlet of Device6 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduF OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduFEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduF outlet."
::= { pduPwrMonitoringOutletPduF 2}
pduPwrMonitoringOutletStatusPduFEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletStatusPduFEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduF outlet."
INDEX { outletPduFIndex}
::= { pduPwrMonitoringOutletStatusTablePduF 1 }
PduPwrMonitoringOutletStatusPduFEntry ::=
SEQUENCE {
outletPduFIndex
INTEGER,
outletPduFState
INTEGER,
outletPduFCurrent
INTEGER,
outletPduFPwrFactor
INTEGER,
outletPduFPower
INTEGER,
outletPduFEnergy
INTEGER,
outletPduFResetFrom
DisplayString,
outletPduFStatus
INTEGER,
outletPduFAppPower
INTEGER,
outletPduFVoltage
INTEGER
}
outletPduFIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet status of PduF."
::= { pduPwrMonitoringOutletStatusPduFEntry 1 }
outletPduFState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 2 }
outletPduFCurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 3 }
outletPduFPwrFactor OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power factor of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 4 }
outletPduFPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The active power of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 5 }
outletPduFEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The energy of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 6 }
outletPduFResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 7 }
outletPduFStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 8 }
outletPduFAppPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The apparent power of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 9 }
outletPduFVoltage OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of PduF outlet."
::= { pduPwrMonitoringOutletStatusPduFEntry 10 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduF
--
-- Outlet of Device6 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduF OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduFEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduF outlet."
::= { pduPwrMonitoringOutletPduF 3}
pduPwrMonitoringOutletCfgPduFEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCfgPduFEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduF outlet."
INDEX { outletCfgPduFIndex}
::= { pduPwrMonitoringOutletCfgTablePduF 1 }
PduPwrMonitoringOutletCfgPduFEntry ::=
SEQUENCE {
outletCfgPduFIndex
INTEGER,
outletCfgPduFName
DisplayString,
outletCfgPduFDelayOnStatus
INTEGER,
outletCfgPduFDelayOnTime
INTEGER,
outletCfgPduFDelayOffStatus
INTEGER,
outletCfgPduFDelayOffTime
INTEGER,
outletCfgPduFReboot
INTEGER,
outletCfgPduFOverCurrCritical
INTEGER,
outletCfgPduFOverCurrWarning
INTEGER,
outletCfgPduFOverPwrCritical
INTEGER,
outletCfgPduFOverPwrWarning
INTEGER
}
outletCfgPduFIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet configuration of PduF."
::= { pduPwrMonitoringOutletCfgPduFEntry 1 }
outletCfgPduFName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name for outlet of PduF."
::= { pduPwrMonitoringOutletCfgPduFEntry 2 }
outletCfgPduFDelayOnStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On status of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 3 }
outletCfgPduFDelayOnTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On time of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 4 }
outletCfgPduFDelayOffStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off status of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 5 }
outletCfgPduFDelayOffTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off time of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 6 }
outletCfgPduFReboot OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On reboot duration of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 7 }
outletCfgPduFOverCurrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of current of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 8 }
outletCfgPduFOverCurrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of current of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 9 }
outletCfgPduFOverPwrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of power of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 10 }
outletCfgPduFOverPwrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of power of PduF outlet."
::= { pduPwrMonitoringOutletCfgPduFEntry 11 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduF
--
-- Outlet of Device6 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduF OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduFEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduF outlet."
::= { pduPwrMonitoringOutletPduF 4}
pduPwrMonitoringOutletCtlPduFEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCtlPduFEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduF outlet."
INDEX { outletCtlPduFIndex}
::= { pduPwrMonitoringOutletCtlTablePduF 1 }
PduPwrMonitoringOutletCtlPduFEntry ::=
SEQUENCE {
outletCtlPduFIndex
INTEGER,
outletCtlPduFControl
INTEGER
}
outletCtlPduFIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet control of PduF."
::= { pduPwrMonitoringOutletCtlPduFEntry 1 }
outletCtlPduFControl OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
immediateOn(2),
delayedOn(3),
immediateOff(4),
delayedOff(5),
immediateCycle(6),
delayedCycle(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control-type of PduF outlet."
::= { pduPwrMonitoringOutletCtlPduFEntry 2 }
pduPwrMonitoringOutletPduG OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 7 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduG
--
-- Outlet of Device7 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduG OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PduG Outlet."
::= { pduPwrMonitoringOutletPduG 1}
-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduG
--
-- Outlet of Device7 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduG OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduG outlet."
::= { pduPwrMonitoringOutletPduG 2}
pduPwrMonitoringOutletStatusPduGEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletStatusPduGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduG outlet."
INDEX { outletPduGIndex}
::= { pduPwrMonitoringOutletStatusTablePduG 1 }
PduPwrMonitoringOutletStatusPduGEntry ::=
SEQUENCE {
outletPduGIndex
INTEGER,
outletPduGState
INTEGER,
outletPduGCurrent
INTEGER,
outletPduGPwrFactor
INTEGER,
outletPduGPower
INTEGER,
outletPduGEnergy
INTEGER,
outletPduGResetFrom
DisplayString,
outletPduGStatus
INTEGER,
outletPduGAppPower
INTEGER,
outletPduGVoltage
INTEGER
}
outletPduGIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet status of PduG."
::= { pduPwrMonitoringOutletStatusPduGEntry 1 }
outletPduGState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 2 }
outletPduGCurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 3 }
outletPduGPwrFactor OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power factor of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 4 }
outletPduGPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The active power of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 5 }
outletPduGEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The energy of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 6 }
outletPduGResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 7 }
outletPduGStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 8 }
outletPduGAppPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The apparent power of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 9 }
outletPduGVoltage OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of PduG outlet."
::= { pduPwrMonitoringOutletStatusPduGEntry 10 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduG
--
-- Outlet of Device7 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduG OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduG outlet."
::= { pduPwrMonitoringOutletPduG 3}
pduPwrMonitoringOutletCfgPduGEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCfgPduGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduG outlet."
INDEX { outletCfgPduGIndex}
::= { pduPwrMonitoringOutletCfgTablePduG 1 }
PduPwrMonitoringOutletCfgPduGEntry ::=
SEQUENCE {
outletCfgPduGIndex
INTEGER,
outletCfgPduGName
DisplayString,
outletCfgPduGDelayOnStatus
INTEGER,
outletCfgPduGDelayOnTime
INTEGER,
outletCfgPduGDelayOffStatus
INTEGER,
outletCfgPduGDelayOffTime
INTEGER,
outletCfgPduGReboot
INTEGER,
outletCfgPduGOverCurrCritical
INTEGER,
outletCfgPduGOverCurrWarning
INTEGER,
outletCfgPduGOverPwrCritical
INTEGER,
outletCfgPduGOverPwrWarning
INTEGER
}
outletCfgPduGIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet configuration of PduG."
::= { pduPwrMonitoringOutletCfgPduGEntry 1 }
outletCfgPduGName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name for outlet of PduG."
::= { pduPwrMonitoringOutletCfgPduGEntry 2 }
outletCfgPduGDelayOnStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On status of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 3 }
outletCfgPduGDelayOnTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On time of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 4 }
outletCfgPduGDelayOffStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off status of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 5 }
outletCfgPduGDelayOffTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off time of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 6 }
outletCfgPduGReboot OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On reboot duration of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 7 }
outletCfgPduGOverCurrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of current of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 8 }
outletCfgPduGOverCurrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of current of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 9 }
outletCfgPduGOverPwrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of power of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 10 }
outletCfgPduGOverPwrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of power of PduG outlet."
::= { pduPwrMonitoringOutletCfgPduGEntry 11 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduG
--
-- Outlet of Device7 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduG OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduG outlet."
::= { pduPwrMonitoringOutletPduG 4}
pduPwrMonitoringOutletCtlPduGEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCtlPduGEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduG outlet."
INDEX { outletCtlPduGIndex}
::= { pduPwrMonitoringOutletCtlTablePduG 1 }
PduPwrMonitoringOutletCtlPduGEntry ::=
SEQUENCE {
outletCtlPduGIndex
INTEGER,
outletCtlPduGControl
INTEGER
}
outletCtlPduGIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet control of PduG."
::= { pduPwrMonitoringOutletCtlPduGEntry 1 }
outletCtlPduGControl OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
immediateOn(2),
delayedOn(3),
immediateOff(4),
delayedOff(5),
immediateCycle(6),
delayedCycle(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control-type of PduG outlet."
::= { pduPwrMonitoringOutletCtlPduGEntry 2 }
pduPwrMonitoringOutletPduH OBJECT IDENTIFIER ::= { pduPwrMonitoringOutlet 8 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletPduH
--
-- Outlet of Device8 management Group.
--
-- ===========================================================================
pduPwrMonitoringOutletNumPduH OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PduH Outlet."
::= { pduPwrMonitoringOutletPduH 1}
-- ===========================================================================
--
-- pduPwrMonitoringOutletStatusTablePduH
--
-- Outlet of Device8 Status Group.
--
-- ===========================================================================
pduPwrMonitoringOutletStatusTablePduH OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletStatusPduHEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduH outlet."
::= { pduPwrMonitoringOutletPduH 2}
pduPwrMonitoringOutletStatusPduHEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletStatusPduHEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of PduH outlet."
INDEX { outletPduHIndex}
::= { pduPwrMonitoringOutletStatusTablePduH 1 }
PduPwrMonitoringOutletStatusPduHEntry ::=
SEQUENCE {
outletPduHIndex
INTEGER,
outletPduHState
INTEGER,
outletPduHCurrent
INTEGER,
outletPduHPwrFactor
INTEGER,
outletPduHPower
INTEGER,
outletPduHEnergy
INTEGER,
outletPduHResetFrom
DisplayString,
outletPduHStatus
INTEGER,
outletPduHAppPower
INTEGER,
outletPduHVoltage
INTEGER
}
outletPduHIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet status of PduH."
::= { pduPwrMonitoringOutletStatusPduHEntry 1 }
outletPduHState OBJECT-TYPE
SYNTAX INTEGER {
off(1),
on(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 2 }
outletPduHCurrent OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.01A"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 3 }
outletPduHPwrFactor OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The power factor of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 4 }
outletPduHPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The active power of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 5 }
outletPduHEnergy OBJECT-TYPE
SYNTAX INTEGER
UNITS "KWh"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The energy of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 6 }
outletPduHResetFrom OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The reset date of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 7 }
outletPduHStatus OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 8 }
outletPduHAppPower OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1W"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The apparent power of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 9 }
outletPduHVoltage OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1V"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The voltage of PduH outlet."
::= { pduPwrMonitoringOutletStatusPduHEntry 10 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCfgTablePduH
--
-- Outlet of Device8 Configuration Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCfgTablePduH OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCfgPduHEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduH outlet."
::= { pduPwrMonitoringOutletPduH 3}
pduPwrMonitoringOutletCfgPduHEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCfgPduHEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configuration of PduH outlet."
INDEX { outletCfgPduHIndex}
::= { pduPwrMonitoringOutletCfgTablePduH 1 }
PduPwrMonitoringOutletCfgPduHEntry ::=
SEQUENCE {
outletCfgPduHIndex
INTEGER,
outletCfgPduHName
DisplayString,
outletCfgPduHDelayOnStatus
INTEGER,
outletCfgPduHDelayOnTime
INTEGER,
outletCfgPduHDelayOffStatus
INTEGER,
outletCfgPduHDelayOffTime
INTEGER,
outletCfgPduHReboot
INTEGER,
outletCfgPduHOverCurrCritical
INTEGER,
outletCfgPduHOverCurrWarning
INTEGER,
outletCfgPduHOverPwrCritical
INTEGER,
outletCfgPduHOverPwrWarning
INTEGER
}
outletCfgPduHIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet configuration of PduH."
::= { pduPwrMonitoringOutletCfgPduHEntry 1 }
outletCfgPduHName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name for outlet of PduH."
::= { pduPwrMonitoringOutletCfgPduHEntry 2 }
outletCfgPduHDelayOnStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On status of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 3 }
outletCfgPduHDelayOnTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On time of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 4 }
outletCfgPduHDelayOffStatus OBJECT-TYPE
SYNTAX INTEGER {
nodelay(1),
delay(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off status of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 5 }
outletCfgPduHDelayOffTime OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay Off time of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 6 }
outletCfgPduHReboot OBJECT-TYPE
SYNTAX INTEGER
UNITS "seconds"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Delay On reboot duration of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 7 }
outletCfgPduHOverCurrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of current of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 8 }
outletCfgPduHOverCurrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1A"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of current of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 9 }
outletCfgPduHOverPwrCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Critical Threshold of power of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 10 }
outletCfgPduHOverPwrWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "1W"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Warning Threshold of power of PduH outlet."
::= { pduPwrMonitoringOutletCfgPduHEntry 11 }
-- ===========================================================================
--
-- pduPwrMonitoringOutletCtlTablePduH
--
-- Outlet of Device8 Control Group.
--
-- ===========================================================================
pduPwrMonitoringOutletCtlTablePduH OBJECT-TYPE
SYNTAX SEQUENCE OF PduPwrMonitoringOutletCtlPduHEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduH outlet."
::= { pduPwrMonitoringOutletPduH 4}
pduPwrMonitoringOutletCtlPduHEntry OBJECT-TYPE
SYNTAX PduPwrMonitoringOutletCtlPduHEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display control of PduH outlet."
INDEX { outletCtlPduHIndex}
::= { pduPwrMonitoringOutletCtlTablePduH 1 }
PduPwrMonitoringOutletCtlPduHEntry ::=
SEQUENCE {
outletCtlPduHIndex
INTEGER,
outletCtlPduHControl
INTEGER
}
outletCtlPduHIndex OBJECT-TYPE
SYNTAX INTEGER (0..41)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to outlet control of PduH."
::= { pduPwrMonitoringOutletCtlPduHEntry 1 }
outletCtlPduHControl OBJECT-TYPE
SYNTAX INTEGER {
nothing(1),
immediateOn(2),
delayedOn(3),
immediateOff(4),
delayedOff(5),
immediateCycle(6),
delayedCycle(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control-type of PduH outlet."
::= { pduPwrMonitoringOutletCtlPduHEntry 2 }
-- ===========================================================================
--
-- PduEnvMonitoringStatus
--
-- Emd Status Group.
--
-- ===========================================================================
pduEmdStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduEnvMonitoringStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of EMD."
::= { pduEnvMonitoring 1 }
pduEnvMonitoringStatus OBJECT-TYPE
SYNTAX PduEnvMonitoringStatus
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display status of EMD."
INDEX { pduEnvStatusIndex}
::= { pduEmdStatusTable 1 }
PduEnvMonitoringStatus ::=
SEQUENCE {
pduEnvStatusIndex
INTEGER,
pduEnvMonitoringTemp
INTEGER,
pduEnvMonitoringHumi
INTEGER,
pduEnvMonitoringTempAlarm
INTEGER,
pduEnvMonitoringHumiAlarm
INTEGER,
pduEnvMonitoringAlarm1
INTEGER,
pduEnvMonitoringAlarm2
INTEGER
}
pduEnvStatusIndex OBJECT-TYPE
SYNTAX INTEGER (0..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to EMD status entry."
::= { pduEnvMonitoringStatus 1 }
pduEnvMonitoringTemp OBJECT-TYPE
SYNTAX INTEGER
UNITS "degC"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The temperature of EMD."
::= { pduEnvMonitoringStatus 2 }
pduEnvMonitoringHumi OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The humidity of EMD."
::= { pduEnvMonitoringStatus 3 }
pduEnvMonitoringTempAlarm OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The temperature status of EMD."
::= { pduEnvMonitoringStatus 4 }
pduEnvMonitoringHumiAlarm OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
warning(2),
critical(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The humidity status of EMD."
::= { pduEnvMonitoringStatus 5 }
pduEnvMonitoringAlarm1 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
inactive(2),
active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The alarm-1 status of EMD."
::= { pduEnvMonitoringStatus 6 }
pduEnvMonitoringAlarm2 OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
inactive(2),
active(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The alarm-2 status of EMD."
::= { pduEnvMonitoringStatus 7 }
-- ===========================================================================
--
-- PduEnvMonitoringCfg
--
-- Emd Configuration Group.
--
-- ===========================================================================
pduEmdCfgTable OBJECT-TYPE
SYNTAX SEQUENCE OF PduEnvMonitoringCfg
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configure of EMD."
::= { pduEnvMonitoring 2 }
pduEnvMonitoringCfg OBJECT-TYPE
SYNTAX PduEnvMonitoringCfg
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list to display configure of EMD."
INDEX { pduEnvCfgIndex }
::= { pduEmdCfgTable 1 }
PduEnvMonitoringCfg ::=
SEQUENCE {
pduEnvCfgIndex
INTEGER,
pduEnvMonitoringControl
INTEGER,
pduEnvMonitoringTempHighCritical
INTEGER,
pduEnvMonitoringTempHighWarning
INTEGER,
pduEnvMonitoringTempLowCritical
INTEGER,
pduEnvMonitoringTempLowWarning
INTEGER,
pduEnvMonitoringTempHystersis
INTEGER,
pduEnvMonitoringTempOffset
INTEGER,
pduEnvMonitoringHumiHighCritical
INTEGER,
pduEnvMonitoringHumiHighWarning
INTEGER,
pduEnvMonitoringHumiLowCritical
INTEGER,
pduEnvMonitoringHumiLowWarning
INTEGER,
pduEnvMonitoringHumiHystersis
INTEGER,
pduEnvMonitoringHumiOffset
INTEGER,
pduEnvMonitoringAlarm1Setup
INTEGER,
pduEnvMonitoringAlarm2Setup
INTEGER
}
pduEnvCfgIndex OBJECT-TYPE
SYNTAX INTEGER (0..3)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index to EMD configure entry."
::= { pduEnvMonitoringCfg 1 }
pduEnvMonitoringControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/disable the EMD alarm configuration."
::= { pduEnvMonitoringCfg 2 }
pduEnvMonitoringTempHighCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "degC"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The High Critical Threshold of temperature of EMD."
::= { pduEnvMonitoringCfg 3 }
pduEnvMonitoringTempHighWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "degC"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The High Warning Threshold of temperature of EMD."
::= { pduEnvMonitoringCfg 4 }
pduEnvMonitoringTempLowCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "degC"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Low Critical Threshold of temperature of EMD."
::= { pduEnvMonitoringCfg 5 }
pduEnvMonitoringTempLowWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "degC"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Low Warning Threshold of temperature of EMD."
::= { pduEnvMonitoringCfg 6 }
pduEnvMonitoringTempHystersis OBJECT-TYPE
SYNTAX INTEGER
UNITS "degC"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Hystersis of Temperature of EMD."
::= { pduEnvMonitoringCfg 7 }
pduEnvMonitoringTempOffset OBJECT-TYPE
SYNTAX INTEGER
UNITS "degC"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Offset of Temperature of EMD."
::= { pduEnvMonitoringCfg 8 }
pduEnvMonitoringHumiHighCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The High Crtitcal Threshold of humidity of EMD."
::= { pduEnvMonitoringCfg 9 }
pduEnvMonitoringHumiHighWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The High Warning Threshold of humidity of EMD."
::= { pduEnvMonitoringCfg 10 }
pduEnvMonitoringHumiLowCritical OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Low Crtitcal Threshold of humidity of EMD."
::= { pduEnvMonitoringCfg 11 }
pduEnvMonitoringHumiLowWarning OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Low Warning Threshold of humidity of EMD."
::= { pduEnvMonitoringCfg 12 }
pduEnvMonitoringHumiHystersis OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Hystersis of Humidity of EMD."
::= { pduEnvMonitoringCfg 13 }
pduEnvMonitoringHumiOffset OBJECT-TYPE
SYNTAX INTEGER
UNITS "0.1%"
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Ofset of Humidity of EMD."
::= { pduEnvMonitoringCfg 14 }
pduEnvMonitoringAlarm1Setup OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
no(2),
nc(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Alarm-1 setup of EMD."
::= { pduEnvMonitoringCfg 15 }
pduEnvMonitoringAlarm2Setup OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
no(2),
nc(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Alarm-2 setup of EMD."
::= { pduEnvMonitoringCfg 16 }
-- ===========================================================================
-- pduTraps
--
-- iPoManIII Trap group
-- ===========================================================================
-- This section defines the well-known notifications sent by
-- agents.
pduSystemColdBoot TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Cold boot."
::= 1
pduSystemWarmBoot TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Warm boot."
::= 2
pduSystemRestart TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: System restart."
::= 3
pduResetToDefault TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Parameters reset to default."
::= 4
pduFirmUpgrade TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Firmware upgrade."
::= 5
pduSystemLogClear TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: System log cleared."
::= 6
pduEventlogClear TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Event log cleared."
::= 7
pduInletHistoryClear TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet history log cleared."
::= 8
pduOutletHistoryClear TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet history log cleared."
::= 9
pduSystemTimeChangeUser TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Time changed by user."
::= 10
pduSystemTimeChangeNtp TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Time synced with NTP server."
::= 11
pduSystemTimeChangeRtc TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Time changed by RTC."
::= 12
pduMailTestPass TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Test mail pass."
::= 13
pduMailTestFail TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Test mail failed."
::= 14
pduMailSentPass TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Mail sent successfully."
::= 15
pduMailSentFail TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Mail sent failed."
::= 16
pduSystemCfgChange TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Parameter changed."
::= 17
pduSystemParamImport TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Import XML configuration."
::= 18
pduInletCommLost TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet communication lost."
::= 19
pduInletCommRestore TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet communication restore."
::= 20
pduOutletCommLost TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet communication lost."
::= 21
pduOutletCommRestore TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet communication restore"
::= 22
pduOutletOnUser TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet turned on by user."
::= 23
pduOutletOnSchedule TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet turned on by schedule."
::= 24
pduOutletOffUser TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet turned off by user."
::= 25
pduOutletOffSchedule TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet turned off by schedule."
::= 26
pduOutletRebootUser TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet reboot by user."
::= 27
pduOutletRebootSchedule TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet reboot by schedule."
::= 28
pduInletEnergyReset TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet active energy reset."
::= 29
pduOutletEnergyReset TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet energy reset."
::= 30
pduSetUser TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Assign outlet to user."
::= 31
pduDeletUser TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Delete user."
::= 32
pduUpgradeInletSuccess TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet upgrade successfully."
::= 33
pduUpgradeInletFail TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet upgrade fail."
::= 34
pduUpgradeOutletSuccess TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet upgrade successfully."
::= 35
pduUpgradeOutletFail TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet upgrade fail."
::= 36
pduEmdHistoryLogClear TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: EMD history log cleared."
::= 37
pduAccountResetDefault TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: The default accounts had been reset to default value."
::= 38
pduUpgradeExtEmdSuccess TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: External EMD board upgrade successfully."
::= 39
pduUpgradeExtEmdFail TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: External EMD board upgrade fail."
::= 40
pduGroupOutletChanged TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: The Administrator has changed the authority of Outlet Manager, the Grouping setting will be cleared synchronously."
::= 41
pduScheduleOutletChanged TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: The Administrator has changed the authority of Outlet Manager, the Schedule setting will be cleared synchronously."
::= 42
pduGroupChanged TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: The Outlet Manger has changed the setting of Outlet Grouping, the Schedule will be cleared synchronously."
::= 43
pduSnmpConflicts TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet polling issues due to SNMP conflicts."
::= 44
pduInletEnergyResetPhase1 TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase1 active energy reset."
::= 45
pduInletEnergyResetPhase2 TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase2 active energy reset."
::= 46
pduInletEnergyResetPhase3 TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase3 active energy reset."
::= 47
pduInletREnergyReset TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet reactive energy reset."
::= 48
pduInletREnergyResetPhase1 TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase1 reactive energy reset."
::= 49
pduInletREnergyResetPhase2 TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase2 reactive energy reset."
::= 50
pduInletREnergyResetPhase3 TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase3 reactive energy reset."
::= 51
pduEmdTempHighWarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Temperature had returned from high warning to normal."
::= 101
pduEmdTempHighWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Temperature was higher than high warning set point."
::= 102
pduEmdTempLowWarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Temperature had returned from low warning to normal."
::= 103
pduEmdTempLowWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Temperature was lower than low warning set point."
::= 104
pduEmdTempHighCritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Temperature had returned from high critical to high warning."
::= 105
pduEmdTempHighCritical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Temperature was higher than high critical set point."
::= 106
pduEmdTempLowCritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Temperature had returned from low critical to low warning."
::= 107
pduEmdTempLowCritical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Temperature was lower than low critical set point."
::= 108
pduEmdHumiHighWarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Humidity had returned from high warning to normal."
::= 109
pduEmdHumiHighWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Humidity was higher than high warning set point."
::= 110
pduEmdHumiLowWarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Humidity had returned from low warning to normal."
::= 111
pduEmdHumiLowWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Humidity was lower than low warning set point."
::= 112
pduEmdHumiHighCritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Humidity had returned from high critical to high warning."
::= 113
pduEmdHumiHighCritical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Humidity was higher than high critical set point."
::= 114
pduEmdHumiLowCritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Humidity had returned from low critical to low warning."
::= 115
pduEmdHumiLowCritical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Humidity was lower than low critical set point."
::= 116
pduEmdAlarm1NotActive TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Alarm-1 became inactive."
::= 117
pduEmdAlarm1Active TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Alarm-1 became active."
::= 118
pduEmdAlarm2NotActive TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Alarm-2 became inactive."
::= 119
pduEmdAlarm2Active TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Alarm-2 became active."
::= 120
pduRs485Online TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: RS485 Sensor was online."
::= 121
pduRs485Offline TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: RS485 Sensor was offline."
::= 122
pduInletLoadCritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet load had returned from critical to warning."
::= 123
pduInletLoadCritical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet load was higher than critical set point."
::= 124
pduInletLoadWarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet load had returned from warning to normal."
::= 125
pduInletLoadWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Inlet load was higher than warning set point."
::= 126
pduInletCurrPhase1CritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase1 current had returned from critical to warning."
::= 127
pduInletCurrPhase1Critical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet phase1 current was higher than critical set point."
::= 128
pduInletCurrPhase1WarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase1 current had returned from warning to normal."
::= 129
pduInletCurrPhase1Warn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Inlet phase1 current was higher than warning set point."
::= 130
pduInletCurrPhase2CritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase2 current had returned from critical to warning."
::= 131
pduInletCurrPhase2Critical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet phase2 current was higher than critical set point."
::= 132
pduInletCurrPhase2WarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase2 current had returned from warning to normal."
::= 133
pduInletCurrPhase2Warn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Inlet phase2 current was higher than warning set point."
::= 134
pduInletCurrPhase3CritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase3 current had returned from critical to warning."
::= 135
pduInletCurrPhase3Critical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet phase3 current was higher than critical set point."
::= 136
pduInletCurrPhase3WarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase3 current had returned from warning to normal."
::= 137
pduInletCurrPhase3Warn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Inlet phase3 current had returned from critical to warning."
::= 138
pduInletVoltPhase1CritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase1 voltage had returned from critical to warning."
::= 139
pduInletVoltPhase1Critical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet phase1 voltage was higher than critical set point."
::= 140
pduInletVoltPhase1WarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase1 voltage had returned from warning to normal."
::= 141
pduInletVoltPhase1Warn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Inlet phase1 voltage was higher than warning set point."
::= 142
pduInletVoltPhase2CritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase2 voltage had returned from critical to warning."
::= 143
pduInletVoltPhase2Critical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet phase2 voltage was higher than critical set point."
::= 144
pduInletVoltPhase2WarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase2 voltage had returned from warning to normal."
::= 145
pduInletVoltPhase2Warn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Inlet phase2 voltage was higher than warning set point."
::= 146
pduInletVoltPhase3CritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase3 voltage had returned from critical to warning."
::= 147
pduInletVoltPhase3Critical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet phase3 voltage was higher than critical set point."
::= 148
pduInletVoltPhase3WarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet phase3 voltage had returned from warning to normal."
::= 149
pduInletVoltPhase3Warn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Inlet phase3 voltage was higher than warning set point."
::= 150
pduOutletCurrCritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet current had returned from critical to warning."
::= 151
pduOutletCurrCritical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Outlet current was higher than critical set point."
::= 152
pduOutletCurrWarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet current had returned from warning to normal."
::= 153
pduOutletCurrWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Outlet current was higher than warning set point."
::= 154
pduOutletPwrCritTOWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet power had returned from critical to warning."
::= 155
pduOutletPwrCritical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Outlet power was higher than critical set point."
::= 156
pduOutletPwrWarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Outlet power had returned from warning to normal."
::= 157
pduOutletPwrWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Outlet power was higher than warning set point."
::= 158
pduAlarm1Disabled TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Alarm-1 became disabled."
::= 159
pduAlarm2Disabled TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Alarm-2 became disabled."
::= 160
pduIntetResidualCurrect1Occured TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet Residual current occurred."
::= 161
pduIntetResidualCurrect1Remove TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet Residual current removed."
::= 162
pduInletLoadBalanceCritToWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet load balance had returned from critical to warning."
::= 163
pduInletLoadBalanceCritical TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: Inlet load balance was higher than critical set point."
::= 164
pduInletLoadBalanceWarnToNormal TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Informational: Inlet load balance had returned from warning to normal."
::= 165
pduInletLoadBalanceWarn TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: Inlet load balance was higher than warning set point."
::= 166
pduInletAcFail TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Critical: INPUT AC fail."
::= 167
pduInletAcRestore TRAP-TYPE
ENTERPRISE pduTraps
DESCRIPTION
"Warning: INPUT AC restore."
::= 168