-- Copyright (C) 2005 Paradyne Corporation.
|
|
-- ===============================================================
|
|
|
|
PDN-ADSL-SELT-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE, Integer32, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
OBJECT-GROUP, MODULE-COMPLIANCE
|
|
FROM SNMPv2-CONF
|
|
TEXTUAL-CONVENTION
|
|
FROM SNMPv2-TC
|
|
ifIndex
|
|
FROM IF-MIB
|
|
pdn-interfaces
|
|
FROM PDN-HEADER-MIB;
|
|
|
|
pdnAdslSeltMIB MODULE-IDENTITY
|
|
LAST-UPDATED "200403280000Z" -- March 28, 2005
|
|
ORGANIZATION "Paradyne Networks
|
|
MIB Working Group
|
|
Other information about group editing the MIB"
|
|
CONTACT-INFO "Paradyne Networks, Inc.
|
|
8545 126th Avenue North
|
|
Largo, FL 33733
|
|
www.paradyne.com
|
|
|
|
General Comments to: mibwg_team@paradyne.com
|
|
|
|
Editors
|
|
Jesus Pinto,
|
|
Clay Sikes"
|
|
|
|
DESCRIPTION
|
|
"This MIB module defines a portion of the management information base
|
|
(MIB) for managing configuration and monitoring results of SELT
|
|
(Single Ended Line Test) tests over ADSL interfaces.
|
|
|
|
At the time this MIB was defined, the IETF ADSL MIB Working does
|
|
not have any work on the 'standard' MIBs planned and/or has not produced
|
|
a schedule to address G.SELT needs. As a result, these objects may
|
|
be a `temporary' solution until MIBs/Objects are defined
|
|
meet the needs of ADSL SELT testing.
|
|
|
|
=====================================================================
|
|
== ==
|
|
== Copyright (C) 2005 Paradyne Corporation. ==
|
|
== ==
|
|
====================================================================="
|
|
|
|
REVISION "200503280000Z" -- March 28, 2005
|
|
DESCRIPTION "Added clearResults(4) to pdnAdslSeltCmd to allow an entry in
|
|
the pdnAdslSeltLcTable or the pdnAdslSeltLnfTable to be removed.
|
|
Added resultsCleared(5) to pdnAdslSeltStatus to indicate that
|
|
clearResults(4) have been executed."
|
|
|
|
REVISION "200503100000Z" -- March 10, 2005
|
|
DESCRIPTION "Added notStarted(4) to pdnAdslSeltStatus. This solves the
|
|
problem of what to return when the pdnAdslSeltTable is walked
|
|
prior to a test being run on an interface."
|
|
|
|
REVISION "200412020000Z" -- Dec 02, 2004
|
|
DESCRIPTION "Initial release."
|
|
|
|
|
|
::= { pdn-interfaces 31 }
|
|
|
|
--
|
|
-- Define groups for Notifications, MIB Objects, Accessible for
|
|
-- Notifications (AFNs), and Conformance.
|
|
-- These may just be place holders.
|
|
--
|
|
pdnAdslSeltNotifications OBJECT IDENTIFIER ::= { pdnAdslSeltMIB 0 }
|
|
pdnAdslSeltObjects OBJECT IDENTIFIER ::= { pdnAdslSeltMIB 1 }
|
|
pdnAdslSeltAFNs OBJECT IDENTIFIER ::= { pdnAdslSeltMIB 2 }
|
|
pdnAdslSeltConformance OBJECT IDENTIFIER ::= { pdnAdslSeltMIB 3 }
|
|
|
|
|
|
-- =============================================================================
|
|
-- == Textual Conventions ==
|
|
-- =============================================================================
|
|
|
|
PdnSeltTypes ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This textual convention defines the SELT test types
|
|
available for configuration."
|
|
|
|
SYNTAX INTEGER {
|
|
loopCharacterization (1), -- Loop Characterization
|
|
loopNoiseFloor (2) -- Loop noise floor
|
|
}
|
|
|
|
-- =============================================================================
|
|
-- == MIB Objects ==
|
|
-- =============================================================================
|
|
|
|
pdnAdslSeltWireSize OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
awg (1), -- AWG
|
|
metric (2), -- Metric
|
|
metricJapan (3) -- Metric Japan
|
|
}
|
|
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object permits the selection of the metric unit
|
|
to be used when reporting SELT test results.
|
|
(i.e for AWG results are in feet and for
|
|
metric/metricJapan results are in meters).
|
|
|
|
This configuration parameter applies to all the SELT
|
|
tests run in the device.
|
|
"
|
|
::= { pdnAdslSeltObjects 1 }
|
|
|
|
|
|
-- =================================================
|
|
-- == G.Selt (Single Ended Line Test) Configuration
|
|
-- ==
|
|
-- == This section defines the tables requires to
|
|
-- == support the SELT feature in the system.
|
|
-- ==
|
|
-- == For now, we require Loop Characterization and
|
|
-- == Loop Noise Floor Measurement Tests. Both tests
|
|
-- == types can be started/stopped via a common table
|
|
-- == described below
|
|
--
|
|
-- ================================================
|
|
pdnAdslSeltTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAdslSeltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table allows initiation/termination of
|
|
SELT Tests."
|
|
::= { pdnAdslSeltObjects 2 }
|
|
|
|
pdnAdslSeltEntry OBJECT-TYPE
|
|
SYNTAX PdnAdslSeltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Each entry represents an instance of a SELT test
|
|
currently running or ever run (since last system reset)
|
|
on an ADSL interface.
|
|
|
|
There should be entries in this table for every
|
|
active running tests and test that are in the process
|
|
of being stopped or have terminated already.
|
|
|
|
There should be no entries for ADSL interfaces that
|
|
have not run a test since last since reset; thus,
|
|
the agent should return NO_SUCH_NAME for those cases.
|
|
"
|
|
INDEX { ifIndex, pdnAdslSeltType }
|
|
::= { pdnAdslSeltTable 1 }
|
|
|
|
PdnAdslSeltEntry ::=
|
|
SEQUENCE {
|
|
pdnAdslSeltType PdnSeltTypes,
|
|
pdnAdslSeltCmd INTEGER,
|
|
pdnAdslSeltStatus INTEGER,
|
|
pdnAdslSeltDuration Unsigned32,
|
|
pdnAdslSeltTimeLeft Unsigned32
|
|
}
|
|
|
|
pdnAdslSeltType OBJECT-TYPE
|
|
SYNTAX PdnSeltTypes
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object is used to specify the SELT test type
|
|
that will be initiated.
|
|
|
|
If a SELT Test is already running on the ADSL interface,
|
|
writing to this object is prohibited by the agent until
|
|
the previous test is completed or terminated.
|
|
"
|
|
::= { pdnAdslSeltEntry 1 }
|
|
|
|
pdnAdslSeltCmd OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noOp (1), -- used when reading the object
|
|
start (2), -- start test
|
|
stop (3), -- stop an initiated test
|
|
clearResults (4) -- clears the results for the
|
|
-- pdnAdslSeltType
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object corresponds to the list of test operations
|
|
that can be performed.
|
|
|
|
The possible values are noOp(1), start(2), stop(3), or
|
|
clearResults(4).
|
|
|
|
Reading this object will always return the value 'noOp (1)'.
|
|
|
|
If SELT test is already running on an ADSL interface,
|
|
the only possible test command is 'stop (1)'.
|
|
|
|
The clearResults(4) command clears test results by removing
|
|
and entry in the pdnAdslSeltLcTable or the
|
|
pdnAdslSeltLnfTable. After the execution of this command,
|
|
the appropriate value for pdnAdslSeltStatus would be
|
|
resultsCleared(5).
|
|
"
|
|
::= { pdnAdslSeltEntry 2 }
|
|
|
|
pdnAdslSeltStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inProgress (1),
|
|
stoppedInProgress (2),
|
|
complete (3),
|
|
notStarted (4),
|
|
resultsCleared (5)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object provides status about any SELT test
|
|
running or ever run (since last reset) on an ADSL
|
|
interface. This object can be read by NMS managers
|
|
to determine the status of a test; that is:
|
|
|
|
inProgress (1) - if the test is currently running.
|
|
|
|
stoppedInProgress (2) - if a request to stop the test
|
|
is still in progress.
|
|
|
|
complete (3) - if the test has been run at least
|
|
once since system reset and has
|
|
completed.
|
|
|
|
notStarted (4) - if the test has not been run on
|
|
this interface since last system
|
|
reset.
|
|
|
|
resultsCleared (5) - if the entry in the test results table,
|
|
Lc or Lnf, was removed as the result
|
|
of the execution of the clearResults(4)
|
|
pdnAdslSeltCmd.
|
|
"
|
|
::= { pdnAdslSeltEntry 3 }
|
|
|
|
|
|
pdnAdslSeltDuration OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This object provides the approximate time in Seconds that
|
|
the SELT test measurement will take.
|
|
|
|
This object should return 0 if no test is actively
|
|
running on the ADSL interface specified.
|
|
"
|
|
::= { pdnAdslSeltEntry 4 }
|
|
|
|
pdnAdslSeltTimeLeft OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object provides the approximate time left in Seconds
|
|
for the test running on this ADSL interface.
|
|
|
|
This object should return 0 if no test is actively
|
|
running on the ADSL interface specified.
|
|
"
|
|
::= { pdnAdslSeltEntry 5 }
|
|
|
|
|
|
-- =================================================
|
|
-- == G.Selt (Single Ended Line Test) Results
|
|
-- ==
|
|
-- == LOOP CHARACTERIZATION (Lc) Results Table
|
|
-- ==
|
|
-- == This table is used to post results from an
|
|
-- == initiated Loop Characterization test.
|
|
--
|
|
-- ================================================
|
|
pdnAdslSeltLcTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAdslSeltLcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table post results for loop
|
|
characterization tests completed.
|
|
"
|
|
::= { pdnAdslSeltObjects 3 }
|
|
|
|
pdnAdslSeltLcEntry OBJECT-TYPE
|
|
SYNTAX PdnAdslSeltLcEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Each entry represents the results of a loop
|
|
characterization test performed over an ADSL interface.
|
|
"
|
|
INDEX { ifIndex, pdnAdslSeltLcSegmentIndex }
|
|
::= { pdnAdslSeltLcTable 1 }
|
|
|
|
PdnAdslSeltLcEntry ::=
|
|
SEQUENCE {
|
|
pdnAdslSeltLcSegmentIndex Integer32,
|
|
pdnAdslSeltLcSegmentLength Integer32,
|
|
pdnAdslSeltLcSegmentGauge INTEGER,
|
|
pdnAdslSeltLcSegmentType INTEGER
|
|
}
|
|
|
|
pdnAdslSeltLcSegmentIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..9)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the index of the segment being reported.
|
|
From no segments to a possible of 10 segments could be
|
|
identified in the loop topology.
|
|
"
|
|
::= { pdnAdslSeltLcEntry 1 }
|
|
|
|
pdnAdslSeltLcSegmentLength OBJECT-TYPE
|
|
SYNTAX Integer32(0..65534)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates an estimate of the segment Length
|
|
being reported
|
|
"
|
|
::= { pdnAdslSeltLcEntry 2 }
|
|
|
|
pdnAdslSeltLcSegmentGauge OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
|
|
--AWG--
|
|
awg26 (2),
|
|
awg24 (3),
|
|
awg22 (4),
|
|
awg19 (5),
|
|
|
|
--Metric--
|
|
metric32 (10), -- (0.32mm)
|
|
metric40 (11), -- (0.40mm)
|
|
metric50 (12), -- (0.50mm)
|
|
metric63 (13), -- (0.63mm)
|
|
metric90 (14), -- (0.90mm)
|
|
|
|
--Metric/Japan--
|
|
metricJapan32 (20), -- (0.32mm)
|
|
metricJapan40 (21), -- (0.40mm)
|
|
metricJapan50 (22), -- (0.50mm)
|
|
metricJapan65 (23), -- (0.65mm)
|
|
metricJapan90 (24) -- (0.90mm)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the estimated Gauge of the segment
|
|
being reported. The gauge reported back is based on the
|
|
pdnAdslSeltWireSizeWireSize configuration parameter passed
|
|
when the test is started.
|
|
"
|
|
::= { pdnAdslSeltLcEntry 3 }
|
|
|
|
pdnAdslSeltLcSegmentType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notPresent (1),
|
|
inline (2),
|
|
bridgeTap (3)
|
|
}
|
|
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the segment type being reported.
|
|
"
|
|
::= { pdnAdslSeltLcEntry 4 }
|
|
|
|
-- =================================================
|
|
-- == G.Selt (Single Ended Line Test) Results
|
|
-- ==
|
|
-- == LOOP NOISE FLOOR (Lnf) Results Table
|
|
-- ==
|
|
-- == This table is used to post results from an
|
|
-- == initiated Loop Noise Floor test.
|
|
--
|
|
-- ================================================
|
|
pdnAdslSeltLnfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PdnAdslSeltLnfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "This table post results for loop
|
|
noise floor tests completed.
|
|
"
|
|
::= { pdnAdslSeltObjects 4 }
|
|
|
|
pdnAdslSeltLnfEntry OBJECT-TYPE
|
|
SYNTAX PdnAdslSeltLnfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Each entry represents the results of a Loop
|
|
Noise Floor test performed over an ADSL interface.
|
|
"
|
|
INDEX { ifIndex, pdnAdslSeltLnfSubCarrierIndex }
|
|
::= { pdnAdslSeltLnfTable 1 }
|
|
|
|
PdnAdslSeltLnfEntry ::=
|
|
SEQUENCE {
|
|
pdnAdslSeltLnfSubCarrierIndex Integer32,
|
|
pdnAdslSeltLnfPeakPsd Integer32,
|
|
pdnAdslSeltLnfTotalPsd Integer32,
|
|
pdnAdslSeltLnfSignalPsd Integer32
|
|
}
|
|
|
|
pdnAdslSeltLnfSubCarrierIndex OBJECT-TYPE
|
|
SYNTAX Integer32(0..63)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "Identifies a row in the table based on a subcarrier.
|
|
The subcarrier index ranges from 0 to NSCus-1
|
|
(NSC is Number of Subcarriers) as specified in G.997.1
|
|
where NSCus is the higher subcarrier that can be transmitted
|
|
in the upstream direction. Please refer to the corresponding
|
|
ITU recommendation for specific values of NSCus.
|
|
The `ADSL Values for NSC' comment above lists those
|
|
recommendations."
|
|
::= { pdnAdslSeltLnfEntry 1 }
|
|
|
|
pdnAdslSeltLnfPeakPsd OBJECT-TYPE
|
|
SYNTAX Integer32(0..65534)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the peak Psd of the tone indicated by
|
|
the sub-carrier index.
|
|
|
|
The value returned by the agent for this object is
|
|
expressed in units of 1/256 dBm.
|
|
"
|
|
::= { pdnAdslSeltLnfEntry 2 }
|
|
|
|
pdnAdslSeltLnfTotalPsd OBJECT-TYPE
|
|
SYNTAX Integer32(0..65534)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the total Psd of the tone indicated by
|
|
the sub-carrier index.
|
|
|
|
The value returned by the agent for this object is
|
|
expressed in units of 1/256 dBm.
|
|
"
|
|
::= { pdnAdslSeltLnfEntry 3 }
|
|
|
|
pdnAdslSeltLnfSignalPsd OBJECT-TYPE
|
|
SYNTAX Integer32(0..65534)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the signal Psd of the tone indicated by
|
|
the sub-carrier index.
|
|
|
|
The value returned by the agent for this object is
|
|
expressed in units of 1/256 dBm.
|
|
"
|
|
::= { pdnAdslSeltLnfEntry 4 }
|
|
|
|
-- =============================================================================
|
|
-- == Accessible for Notifications (AFNs) ==
|
|
-- =============================================================================
|
|
-- None defined
|
|
|
|
|
|
|
|
-- =============================================================================
|
|
-- == Traps/Notifications ==
|
|
-- =============================================================================
|
|
-- None defined
|
|
|
|
|
|
|
|
-- =============================================================================
|
|
-- == Conformance Information ==
|
|
-- =============================================================================
|
|
|
|
pdnAdslSeltCompliances OBJECT IDENTIFIER ::= { pdnAdslSeltConformance 1 }
|
|
pdnAdslSeltGroups OBJECT IDENTIFIER ::= { pdnAdslSeltConformance 2 }
|
|
|
|
|
|
-- ===========================
|
|
-- == Compliance Statements ==
|
|
-- ===========================
|
|
|
|
|
|
pdnAdslSeltMIBCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION "The compliance statement for the entities which
|
|
implement the pdnAdslSeltMIB."
|
|
MODULE -- this module
|
|
-- No mandatory groups are specified
|
|
|
|
GROUP pdnAdslSeltGroup
|
|
DESCRIPTION "The group associates the objects related to the
|
|
configuration of SELT tests in General."
|
|
|
|
GROUP pdnAdslSeltLcGroup
|
|
DESCRIPTION "The group associates the objects related to the
|
|
results of a Loop characterization SELT test."
|
|
|
|
GROUP pdnAdslSeltLnfGroup
|
|
DESCRIPTION "The group associates the objects related to the
|
|
results of a Loop Noise Floor SELT test."
|
|
|
|
|
|
-- All objects, if implemented, are expected to be implemented to the
|
|
-- maximal level as specified in their OBJECT-TYPE macro.
|
|
--
|
|
|
|
::= { pdnAdslSeltCompliances 1 }
|
|
|
|
|
|
-- ==========================
|
|
-- == Units of Conformance ==
|
|
-- ==========================
|
|
|
|
pdnAdslSeltObjGroups OBJECT IDENTIFIER ::= { pdnAdslSeltGroups 1 }
|
|
pdnAdslSeltAfnGroups OBJECT IDENTIFIER ::= { pdnAdslSeltGroups 2 }
|
|
pdnAdslSeltNtfyGroups OBJECT IDENTIFIER ::= { pdnAdslSeltGroups 3 }
|
|
|
|
-- ===================
|
|
-- == Object Groups ==
|
|
-- ===================
|
|
|
|
pdnAdslSeltGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAdslSeltCmd,
|
|
pdnAdslSeltStatus,
|
|
pdnAdslSeltWireSize,
|
|
pdnAdslSeltDuration,
|
|
pdnAdslSeltTimeLeft
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "General configuration of SELT tests."
|
|
|
|
::= { pdnAdslSeltObjGroups 1 }
|
|
|
|
pdnAdslSeltLcGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAdslSeltLcSegmentLength,
|
|
pdnAdslSeltLcSegmentGauge,
|
|
pdnAdslSeltLcSegmentType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Objects related to results posted for Loop
|
|
Characterization Test."
|
|
|
|
::= { pdnAdslSeltObjGroups 2 }
|
|
|
|
pdnAdslSeltLnfGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
pdnAdslSeltLnfPeakPsd,
|
|
pdnAdslSeltLnfTotalPsd,
|
|
pdnAdslSeltLnfSignalPsd
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Objects related to results posted for Loop
|
|
Signal Floor Test."
|
|
|
|
::= { pdnAdslSeltObjGroups 3 }
|
|
|
|
-- ==================================
|
|
-- == Accessible for Notify Groups ==
|
|
-- ==================================
|
|
-- None.
|
|
|
|
|
|
|
|
-- =========================
|
|
-- == Notification Groups ==
|
|
-- =========================
|
|
-- None.
|
|
|
|
|
|
|
|
-- =========
|
|
-- == END ==
|
|
-- =========
|
|
END
|