1650 lines
41 KiB
Plaintext
1650 lines
41 KiB
Plaintext
SPEED-AMP-MIB DEFINITIONS ::= BEGIN
|
|
|
|
--*****************************************************************************************
|
|
--***** Version History ***************************************************************
|
|
--=========================================================================================
|
|
|
|
--V0.0 14.04.2009 GD: Erste Version SPEED-AMP-MIB
|
|
--V1.0 18.06.2009 GD: ueberarbeitete Version Als Referenz für Implementierung in SNMP
|
|
--V1.1 25.08.2009 GD: Alias Werte hinzugefügt, Umrechnungswerte für ananloge Parameter ergaenzt
|
|
-- Supported Modules:
|
|
-- SPEED-AMPLIFIER
|
|
--*****************************************************************************************
|
|
|
|
IMPORTS
|
|
DisplayString FROM RFC1213-MIB
|
|
OBJECT-TYPE FROM RFC-1212
|
|
TRAP-TYPE FROM RFC-1215
|
|
enterprises, IpAddress, TimeTicks, MODULE-IDENTITY FROM SNMPv2-SMI
|
|
PanDacom FROM PanDacom-MIB
|
|
nmSPEEDCARRIER, amplifier FROM SPEEDCARRIER-MIB
|
|
; -- END of IMPORTS
|
|
|
|
--*******************************************************************
|
|
|
|
speedAmp MODULE-IDENTITY
|
|
LAST-UPDATED "1312120000Z"
|
|
ORGANIZATION "Pan Dacom Direkt GmbH"
|
|
CONTACT-INFO
|
|
"Pan Dacom Direkt GmbH
|
|
Dreieich Plaza 1B
|
|
63303 Dreieich
|
|
Germany
|
|
Tel. : +49 6103/932-333
|
|
Fax. : +49 6103/932-444
|
|
email: kontakt@pandacomdirekt.de
|
|
web : www.pandacomdirekt.de"
|
|
DESCRIPTION "Revision 1.0"
|
|
|
|
REVISION "1312120000Z"
|
|
DESCRIPTION "Revision 5.2.0
|
|
- change of table indexes
|
|
- corrective actions "
|
|
::= { amplifier 1 }
|
|
|
|
--*******************************************************************
|
|
|
|
speedAmpModuleOverviewTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpModuleOverviewEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Speed-Amplifier Module Overview Table"
|
|
::= { speedAmp 1 }
|
|
|
|
speedAmpModuleOverviewEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpModuleOverviewEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Overview Entries"
|
|
INDEX { speedAmpMSlot }
|
|
::= { speedAmpModuleOverviewTable 1 }
|
|
|
|
SpeedAmpModuleOverviewEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSlot INTEGER,
|
|
speedAmpMDevice INTEGER,
|
|
speedAmpMStatus INTEGER,
|
|
speedAmpMSysUpTime TimeTicks,
|
|
speedAmpMTemp INTEGER,
|
|
speedAmpMAlarmState INTEGER,
|
|
speedAmpMSerialNumber DisplayString
|
|
}
|
|
|
|
speedAmpMSlot OBJECT-TYPE
|
|
SYNTAX INTEGER (1..17)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Slot number in Carrier"
|
|
::= { speedAmpModuleOverviewEntry 2 }
|
|
|
|
speedAmpMDevice OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable (0),
|
|
other(1),
|
|
preamp14(2),
|
|
booster17(3),
|
|
booster17OSC(4),
|
|
booster23OSC(5),
|
|
inline17(6),
|
|
inline23(7),
|
|
ramanMaster10(8),
|
|
ramanMaster15(9),
|
|
ramanSlave10(10),
|
|
ramanSlave15(11),
|
|
ramanStandalone10(12),
|
|
ramanStandalone15(13),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "Module DeviceType"
|
|
::= { speedAmpModuleOverviewEntry 3 }
|
|
|
|
speedAmpMStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable (0),
|
|
running (1),
|
|
resetSoftware (2),
|
|
resetConfig (3),
|
|
resetCAN (4),
|
|
resetHardware (5),
|
|
resetStatistic(6),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "Reset States of Module"
|
|
::= { speedAmpModuleOverviewEntry 4 }
|
|
|
|
speedAmpMSysUpTime OBJECT-TYPE
|
|
SYNTAX TimeTicks
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"System Up Time in Seconds"
|
|
::= { speedAmpModuleOverviewEntry 5 }
|
|
|
|
speedAmpMTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Temperature"
|
|
::= { speedAmpModuleOverviewEntry 6 }
|
|
|
|
speedAmpMAlarmState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable (0),
|
|
noAlarm (1),
|
|
activeAlarms (2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Alarm States, if there are active see Event-Table"
|
|
::= { speedAmpModuleOverviewEntry 7 }
|
|
|
|
speedAmpMSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Modules Serial Number"
|
|
::= { speedAmpModuleOverviewEntry 8 }
|
|
|
|
-- *********************************
|
|
-- speedAmpModuleImagesOverview
|
|
|
|
speedAmpModuleImagesOverviewTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpModuleImagesOverviewEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Module Images Table"
|
|
::= { speedAmp 2 }
|
|
|
|
speedAmpModuleImagesOverviewEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpModuleImagesOverviewEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Images Overview Entries"
|
|
INDEX { speedAmpMSlot }
|
|
::= { speedAmpModuleImagesOverviewTable 1 }
|
|
|
|
SpeedAmpModuleImagesOverviewEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSlot INTEGER,
|
|
speedAmpSwKernelImage DisplayString,
|
|
speedAmpSwAppImage DisplayString,
|
|
speedAmpSwUploadStatus INTEGER,
|
|
speedAmpSwUpdateStatus INTEGER,
|
|
speedAmpHwVersion DisplayString
|
|
}
|
|
|
|
speedAmpSwKernelImage OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identification of Bootimage"
|
|
::= { speedAmpModuleImagesOverviewEntry 3 }
|
|
|
|
speedAmpSwAppImage OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identification of Application Image1"
|
|
::= { speedAmpModuleImagesOverviewEntry 4 }
|
|
|
|
speedAmpSwUploadStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable (0),
|
|
ready (1),
|
|
startUpload (2),
|
|
uploadActive (3),
|
|
uploadFailure (4),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Control and Status of UploadProcedure"
|
|
::= { speedAmpModuleImagesOverviewEntry 5 }
|
|
|
|
|
|
speedAmpSwUpdateStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable (0),
|
|
idle (1),
|
|
activateKernel (2),
|
|
activateApplication (3),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"activates SW-Image after netxt reset"
|
|
::= { speedAmpModuleImagesOverviewEntry 6 }
|
|
|
|
speedAmpHwVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Identification of Hardware Version"
|
|
::= { speedAmpModuleImagesOverviewEntry 7 }
|
|
|
|
-- *********************************
|
|
-- SpeedAmpModuleBoardConfig
|
|
|
|
speedAmpModuleBoardConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpModuleBoardConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Module config Table"
|
|
::= { speedAmp 3 }
|
|
|
|
speedAmpModuleBoardConfigEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpModuleBoardConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Overview Entries"
|
|
INDEX { speedAmpMSlot }
|
|
::= { speedAmpModuleBoardConfigTable 1 }
|
|
|
|
SpeedAmpModuleBoardConfigEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSlot INTEGER,
|
|
speedAmpTemperatureHighWarning INTEGER,
|
|
speedAmpTemperatureHighAlarm INTEGER
|
|
}
|
|
|
|
speedAmpTemperatureHighWarning OBJECT-TYPE
|
|
SYNTAX INTEGER(5..60)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Warning Level for Module ambient Temperature (5 - 60 degree Celsius)"
|
|
::= { speedAmpModuleBoardConfigEntry 3 }
|
|
|
|
speedAmpTemperatureHighAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Alarm Level for Module ambient Temperature"
|
|
::= { speedAmpModuleBoardConfigEntry 4 }
|
|
|
|
-- ****************************
|
|
|
|
speedAmpModuleNetworkParameterTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpModuleNetworkParameterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Module Network Parameter Table"
|
|
::= { speedAmp 4 }
|
|
|
|
speedAmpModuleNetworkParameterEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpModuleNetworkParameterEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Network Parameter Entries"
|
|
INDEX { speedAmpMSlot }
|
|
::= { speedAmpModuleNetworkParameterTable 1 }
|
|
|
|
SpeedAmpModuleNetworkParameterEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSlot INTEGER,
|
|
speedAmpMNetworkAdress IpAddress,
|
|
speedAmpMNetworkMask IpAddress,
|
|
speedAmpMNetworkGateway IpAddress,
|
|
speedAmpMNetworkSnmpTrapSink1 IpAddress,
|
|
speedAmpMNetworkSnmpTrapSink2 IpAddress,
|
|
speedAmpMNetworkSnmpTrapSink3 IpAddress,
|
|
speedAmpMNetworkSnmpTrapSink4 IpAddress,
|
|
speedAmpMNetworkSnmpTrapSink5 IpAddress,
|
|
speedAmpMNetworkSnmpReadCommunity DisplayString,
|
|
speedAmpMNetworkSnmpWriteCommunity DisplayString,
|
|
speedAmpMNetworkSysLocation DisplayString,
|
|
speedAmpMNetworkSnmpAgentStatus INTEGER,
|
|
speedAmpMNetworkHttpServerStatus INTEGER,
|
|
speedAmpMNetworkSysname DisplayString,
|
|
speedAmpNNetworkSyscontact DisplayString,
|
|
speedAmpMNetworkUserTimeout INTEGER,
|
|
speedAmpMNetworkAccess INTEGER
|
|
}
|
|
|
|
speedAmpMNetworkAdress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP-address of the Ethernet interface"
|
|
DEFVAL { 'c0a80065'H } -- 192.168.0.101
|
|
::= { speedAmpModuleNetworkParameterEntry 3 }
|
|
|
|
speedAmpMNetworkMask OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"IP-netmask of the Ethernet interface"
|
|
DEFVAL { 'ffffff00'H } -- 255.255.255.0
|
|
::= { speedAmpModuleNetworkParameterEntry 4 }
|
|
|
|
speedAmpMNetworkGateway OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"default gateway of the Ethernet interface"
|
|
DEFVAL { '00000000'H }
|
|
::= { speedAmpModuleNetworkParameterEntry 5 }
|
|
|
|
speedAmpMNetworkSnmpTrapSink1 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap destination 1 for SNMP traps. Clear value is 0.0.0.0"
|
|
DEFVAL { '00000000'H }
|
|
::= { speedAmpModuleNetworkParameterEntry 6 }
|
|
|
|
speedAmpMNetworkSnmpTrapSink2 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap destination 2 for SNMP traps. Clear value is 0.0.0.0"
|
|
DEFVAL { '00000000'H }
|
|
::= { speedAmpModuleNetworkParameterEntry 7 }
|
|
|
|
speedAmpMNetworkSnmpTrapSink3 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap destination 3 for SNMP traps. Clear value is 0.0.0.0"
|
|
DEFVAL { '00000000'H }
|
|
::= { speedAmpModuleNetworkParameterEntry 8 }
|
|
|
|
speedAmpMNetworkSnmpTrapSink4 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap destination 4 for SNMP traps. Clear value is 0.0.0.0"
|
|
DEFVAL { '00000000'H }
|
|
::= { speedAmpModuleNetworkParameterEntry 9 }
|
|
|
|
speedAmpMNetworkSnmpTrapSink5 OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Trap destination 5 for SNMP traps. Clear value is 0.0.0.0"
|
|
DEFVAL { '00000000'H }
|
|
::= { speedAmpModuleNetworkParameterEntry 10 }
|
|
|
|
speedAmpMNetworkSnmpReadCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP read community name"
|
|
DEFVAL { "public" }
|
|
::= { speedAmpModuleNetworkParameterEntry 11 }
|
|
|
|
speedAmpMNetworkSnmpWriteCommunity OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SNMP write community name"
|
|
DEFVAL { "private" }
|
|
::= { speedAmpModuleNetworkParameterEntry 12 }
|
|
|
|
speedAmpMNetworkSysLocation OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"location of the SPEED-Amplifier System"
|
|
DEFVAL { "serverroom" }
|
|
::= { speedAmpModuleNetworkParameterEntry 13 }
|
|
|
|
speedAmpMNetworkSnmpAgentStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
down(1),
|
|
up(2),
|
|
notImplemented(254),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Snmp-Agent operational status"
|
|
::= { speedAmpModuleNetworkParameterEntry 14 }
|
|
|
|
speedAmpMNetworkHttpServerStatus OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
down(1),
|
|
up(2),
|
|
notImplemented(254),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Snmp-Agent operational status"
|
|
::= { speedAmpModuleNetworkParameterEntry 15 }
|
|
|
|
speedAmpMNetworkSysname OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"location of the SPEED-Amplifier System"
|
|
DEFVAL { "serverroom" }
|
|
::= { speedAmpModuleNetworkParameterEntry 16 }
|
|
|
|
speedAmpNNetworkSyscontact OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"location of the SPEED-Amplifier System"
|
|
DEFVAL { "serverroom" }
|
|
::= { speedAmpModuleNetworkParameterEntry 17 }
|
|
|
|
speedAmpMNetworkUserTimeout OBJECT-TYPE
|
|
SYNTAX INTEGER (120..3600)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Command line access mode"
|
|
::= { speedAmpModuleNetworkParameterEntry 18 }
|
|
|
|
speedAmpMNetworkAccess OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notavailable(0),
|
|
off(1),
|
|
telnet(2),
|
|
ssh2(3),
|
|
notImplemented(254),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Command line access mode"
|
|
::= { speedAmpModuleNetworkParameterEntry 19 }
|
|
|
|
-- ****************************
|
|
-- SpeedAmpModuleEthPortOverview
|
|
speedAmpModuleEthPortOverviewTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpModuleEthPortOverviewEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Module Ethernet port overview table"
|
|
::= { speedAmp 5 }
|
|
|
|
speedAmpModuleEthPortOverviewEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpModuleEthPortOverviewEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"port overview entries"
|
|
INDEX { speedAmpIndex }
|
|
::= { speedAmpModuleEthPortOverviewTable 1 }
|
|
|
|
SpeedAmpModuleEthPortOverviewEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpIndex INTEGER,
|
|
speedAmpMEthSlot INTEGER,
|
|
speedAmpMEthPort INTEGER,
|
|
speedAmpMEthPortname DisplayString,
|
|
speedAmpMEthPortAdminState INTEGER,
|
|
speedAmpMEthPortOperState INTEGER,
|
|
speedAmpMEthPortMode INTEGER,
|
|
speedAmpMEthSFPState INTEGER,
|
|
speedAmpMEthPortRxPackets INTEGER,
|
|
speedAmpMEthPortTxPackets INTEGER,
|
|
speedAmpMEthErrors INTEGER
|
|
}
|
|
|
|
speedAmpIndex OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1800)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION "SPEED AMP Module Index"
|
|
::= { speedAmpModuleEthPortOverviewEntry 1 }
|
|
|
|
speedAmpMEthSlot OBJECT-TYPE
|
|
SYNTAX INTEGER (1..17)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"number of Module Eth port"
|
|
::= { speedAmpModuleEthPortOverviewEntry 2 }
|
|
|
|
speedAmpMEthPort OBJECT-TYPE
|
|
SYNTAX INTEGER (0..5)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"number of Module Eth port"
|
|
::= { speedAmpModuleEthPortOverviewEntry 3 }
|
|
|
|
speedAmpMEthPortname OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Port description or port name."
|
|
::= { speedAmpModuleEthPortOverviewEntry 4 }
|
|
|
|
speedAmpMEthPortAdminState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
adminDown(1),
|
|
adminUp(2),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"administrativ port status"
|
|
::= { speedAmpModuleEthPortOverviewEntry 5 }
|
|
|
|
speedAmpMEthPortOperState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
down(1),
|
|
up(2),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Eth Port operational status"
|
|
::= { speedAmpModuleEthPortOverviewEntry 6 }
|
|
|
|
speedAmpMEthPortMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
autoneg(1),
|
|
hdx10(2),
|
|
fdx10(3),
|
|
hdx100(4),
|
|
fdx100(5),
|
|
hdlc(6),
|
|
rmii(7),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Eth Port Configuration Mode."
|
|
::= { speedAmpModuleEthPortOverviewEntry 7 }
|
|
|
|
speedAmpMEthSFPState OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
sfpOperDown(1),
|
|
sfpOperUp(2),
|
|
sfpTxFault(3),
|
|
sfpInstalled(4),
|
|
sfpRemoved(5),
|
|
sfpNotPossible(6),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP installed / alarm status"
|
|
::= { speedAmpModuleEthPortOverviewEntry 8 }
|
|
|
|
speedAmpMEthPortRxPackets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Eth Port received Packets"
|
|
::= { speedAmpModuleEthPortOverviewEntry 9 }
|
|
|
|
speedAmpMEthPortTxPackets OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Eth Port transmitted Packets"
|
|
::= { speedAmpModuleEthPortOverviewEntry 10 }
|
|
|
|
speedAmpMEthErrors OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Eth Port received Errors"
|
|
::= { speedAmpModuleEthPortOverviewEntry 11 }
|
|
|
|
|
|
--********************************************
|
|
-- SpeedAmpModuleEthPortConfig
|
|
|
|
speedAmpMEthPortConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpMEthPortConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-Amplifier Module Ethernet port config table"
|
|
::= { speedAmp 6 }
|
|
|
|
speedAmpMEthPortConfigEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpMEthPortConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"port config Entries"
|
|
INDEX { speedAmpIndex }
|
|
::= { speedAmpMEthPortConfigTable 1 }
|
|
|
|
SpeedAmpMEthPortConfigEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMEthSlot INTEGER,
|
|
speedAmpMEthPort INTEGER,
|
|
speedAmpMEthPCfgAdminConfig INTEGER,
|
|
speedAmpMEthPCfgDescription DisplayString,
|
|
speedAmpMEthPCfgMode INTEGER,
|
|
speedAmpMEthPCfgAlarmReporting INTEGER,
|
|
speedAmpMEthPCfgAlarmSchedule INTEGER
|
|
}
|
|
|
|
speedAmpMEthPCfgAdminConfig OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
adminDown(1),
|
|
adminUp(2),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Ethernet port administrative configuration. Only ports 1..4 are configurable."
|
|
::= { speedAmpMEthPortConfigEntry 4 }
|
|
|
|
speedAmpMEthPCfgDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Ethernet port description. Only ports 1..3 are configurable."
|
|
::= { speedAmpMEthPortConfigEntry 5 }
|
|
|
|
speedAmpMEthPCfgMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
autoneg(1),
|
|
fix10HDX(2),
|
|
fix10FDX(3),
|
|
fix100HDX(4),
|
|
fix100FDX(5),
|
|
fixhdlc(6),
|
|
fixrmii(7),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module Ethernet Port Configuration. Only ports 1 and 2 are configurable."
|
|
::= { speedAmpMEthPortConfigEntry 6 }
|
|
|
|
speedAmpMEthPCfgAlarmReporting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
alarmReportingEnabled(1),
|
|
alarmReportingDisabledbySchedule(2),
|
|
alarmReportingDisabledPermanent(3),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet port alarm deactivation. Only applicable for user SFP!"
|
|
::= { speedAmpMEthPortConfigEntry 7 }
|
|
|
|
speedAmpMEthPCfgAlarmSchedule OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1200)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Ethernet port alarm deactivation schedule. Value in hours. After this time has elapsed, the alarms are active again. Only applicable for user SFP!"
|
|
::= { speedAmpMEthPortConfigEntry 8 }
|
|
|
|
--***************************************
|
|
-- SpeedAmpModuleGeneralSFPInfos
|
|
|
|
speedAmpModuleGeneralSFPInfosTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpModuleGeneralSFPInfosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER SFP general information table"
|
|
::= { speedAmp 7 }
|
|
|
|
speedAmpModuleGeneralSFPInfosEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpModuleGeneralSFPInfosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module SFP general information Entries"
|
|
INDEX { speedAmpIndex }
|
|
::= { speedAmpModuleGeneralSFPInfosTable 1 }
|
|
|
|
SpeedAmpModuleGeneralSFPInfosEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSFPSlot INTEGER,
|
|
speedAmpMSFPPort INTEGER,
|
|
speedAmpSFPVendorName DisplayString,
|
|
speedAmpSFPPartNumber DisplayString,
|
|
speedAmpSFPSerialNumber DisplayString,
|
|
speedAmpSFPWavelength INTEGER,
|
|
speedAmpSFPDMIMode INTEGER,
|
|
speedAmpSFPPortType INTEGER
|
|
}
|
|
|
|
speedAmpMSFPSlot OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP slot"
|
|
::= { speedAmpModuleGeneralSFPInfosEntry 2 }
|
|
|
|
speedAmpMSFPPort OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP port"
|
|
::= { speedAmpModuleGeneralSFPInfosEntry 3 }
|
|
|
|
speedAmpSFPVendorName OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP vendor name"
|
|
::= { speedAmpModuleGeneralSFPInfosEntry 4 }
|
|
|
|
speedAmpSFPPartNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP part number"
|
|
::= { speedAmpModuleGeneralSFPInfosEntry 5 }
|
|
|
|
speedAmpSFPSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP serial number"
|
|
::= { speedAmpModuleGeneralSFPInfosEntry 6 }
|
|
|
|
speedAmpSFPWavelength OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP wavelength in units of 100*(value of 1nm)"
|
|
::= { speedAmpModuleGeneralSFPInfosEntry 7 }
|
|
|
|
speedAmpSFPDMIMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
sff8472V93(1),
|
|
sff8472V95(2),
|
|
sff8472V102(3),
|
|
sffVother(4),
|
|
notImplemented(254),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP DMI Type "
|
|
::= { speedAmpModuleGeneralSFPInfosEntry 8 }
|
|
|
|
speedAmpSFPPortType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
osc(1),
|
|
user(2),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP Port Type "
|
|
::= { speedAmpModuleGeneralSFPInfosEntry 9 }
|
|
|
|
-- ****************************************
|
|
-- SpeedAmpModuleSFPMessurement
|
|
|
|
speedAmpModuleSFPMessurementTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpModuleSFPMessurementEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER SFP messurement table"
|
|
::= { speedAmp 8 }
|
|
|
|
speedAmpModuleSFPMessurementEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpModuleSFPMessurementEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP messurement Entries"
|
|
INDEX { speedAmpIndex }
|
|
::= { speedAmpModuleSFPMessurementTable 1 }
|
|
|
|
SpeedAmpModuleSFPMessurementEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSFPSlot INTEGER,
|
|
speedAmpMSFPPort INTEGER,
|
|
speedAmpMSFPRXPower INTEGER,
|
|
speedAmpMSFPTXPower INTEGER,
|
|
speedAmpMSFPTXBias INTEGER,
|
|
speedAmpMSFPTemp INTEGER,
|
|
speedAmpMSFPPortType INTEGER
|
|
}
|
|
|
|
speedAmpMSFPRXPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP optical receive power in units of 10*(value of 1dbm)"
|
|
::= { speedAmpModuleSFPMessurementEntry 4 }
|
|
|
|
speedAmpMSFPTXPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP optical transmit power in units of 10*(value of 1dbm)"
|
|
::= { speedAmpModuleSFPMessurementEntry 5 }
|
|
|
|
speedAmpMSFPTXBias OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP TX Bias in units of 1mA "
|
|
::= { speedAmpModuleSFPMessurementEntry 6 }
|
|
|
|
speedAmpMSFPTemp OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP temperature in units of 1degree Centigrade"
|
|
::= { speedAmpModuleSFPMessurementEntry 7 }
|
|
|
|
speedAmpMSFPPortType OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
osc(1),
|
|
user(2),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SFP Port Type "
|
|
::= { speedAmpModuleSFPMessurementEntry 8 }
|
|
|
|
--***************************************
|
|
-- SpeedAmpDeviceGeneralInfos
|
|
|
|
speedAmpDevGeneralInfosTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpDevGeneralInfosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Amplifier device general information table"
|
|
::= { speedAmp 9 }
|
|
|
|
speedAmpDevGeneralInfosEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpDevGeneralInfosEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier device general information Entries"
|
|
INDEX { speedAmpMSlot }
|
|
::= { speedAmpDevGeneralInfosTable 1 }
|
|
|
|
SpeedAmpDevGeneralInfosEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSlot INTEGER,
|
|
speedAmpDevSerialNumber DisplayString,
|
|
speedAmpDevConfiguration INTEGER,
|
|
speedAmpDevModuletype INTEGER,
|
|
speedAmpDevVersion DisplayString,
|
|
speedAmpDevVendor INTEGER,
|
|
speedAmpDevLinePortDescription DisplayString,
|
|
speedAmpDevClientPortDescription DisplayString
|
|
}
|
|
|
|
speedAmpDevSerialNumber OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Device Serial Number"
|
|
::= { speedAmpDevGeneralInfosEntry 3 }
|
|
|
|
speedAmpDevConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
confConstantPower(3),
|
|
confConstantGain(4),
|
|
confOFF(5),
|
|
confOther(6),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Device Configuration"
|
|
::= { speedAmpDevGeneralInfosEntry 4 }
|
|
|
|
speedAmpDevModuletype OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable (0),
|
|
other(1),
|
|
preamp14(2),
|
|
booster17(3),
|
|
booster17OSC(4),
|
|
booster23OSC(5),
|
|
inline17(6),
|
|
inline23(7),
|
|
ramanMaster10(8),
|
|
ramanMaster15(9),
|
|
ramanSlave10(10),
|
|
ramanSlave15(11),
|
|
ramanStandalone10(12),
|
|
ramanStandalone15(13),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Device Type"
|
|
::= { speedAmpDevGeneralInfosEntry 5 }
|
|
|
|
speedAmpDevVersion OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..17))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Device Version Code "
|
|
::= { speedAmpDevGeneralInfosEntry 6 }
|
|
|
|
speedAmpDevVendor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Device Vendor Code"
|
|
::= { speedAmpDevGeneralInfosEntry 7 }
|
|
|
|
speedAmpDevLinePortDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Optical Line Port Description String "
|
|
::= { speedAmpDevGeneralInfosEntry 8 }
|
|
|
|
speedAmpDevClientPortDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Optical Client Port Description String "
|
|
::= { speedAmpDevGeneralInfosEntry 9 }
|
|
|
|
--***************************************
|
|
-- SpeedAmpDeviceOverview
|
|
|
|
speedAmpDevOverviewTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpDevOverviewEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Amplifier device Overview table"
|
|
::= { speedAmp 10 }
|
|
|
|
speedAmpDevOverviewEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpDevOverviewEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier device Overview Entries"
|
|
INDEX { speedAmpMSlot }
|
|
::= { speedAmpDevOverviewTable 1 }
|
|
|
|
SpeedAmpDevOverviewEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSlot INTEGER,
|
|
speedAmpDevGain INTEGER,
|
|
speedAmpDevPumpCurrent INTEGER,
|
|
speedAmpDevPumpPower INTEGER,
|
|
speedAmpDevMode INTEGER,
|
|
speedAmpDevModeShutdown INTEGER,
|
|
speedAmpDevLosInputThreshold INTEGER,
|
|
speedAmpDevHighOutputThreshold INTEGER,
|
|
speedAmpDevAlarm INTEGER,
|
|
speedAmpDevCaseTemperature INTEGER,
|
|
speedAmpDevClientInputPower INTEGER,
|
|
speedAmpDevLineOutputPower INTEGER,
|
|
speedAmpDevBackreflectionThreshold INTEGER,
|
|
speedAmpDevShutdownThreshold INTEGER,
|
|
speedAmpDevBackreflectionRatio INTEGER
|
|
}
|
|
|
|
speedAmpDevGain OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier optical Gain in units of 100*(value of 1db)"
|
|
::= { speedAmpDevOverviewEntry 3 }
|
|
|
|
speedAmpDevPumpCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Pump Current in units of 10*(value of 1mA)"
|
|
::= { speedAmpDevOverviewEntry 4 }
|
|
|
|
speedAmpDevPumpPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Pump Power in units of 10*(value of 1mW)"
|
|
::= { speedAmpDevOverviewEntry 5 }
|
|
|
|
speedAmpDevMode OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
confConstantPower(3),
|
|
confConstantGain(4),
|
|
confOFF(5),
|
|
confOther(6),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Working Mode"
|
|
::= { speedAmpDevOverviewEntry 6 }
|
|
|
|
speedAmpDevModeShutdown OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable (0),
|
|
cfgAutoLaserShutdownOff (1),
|
|
cfgAutoLaserShutdownOn (2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Shutdown Mode"
|
|
::= { speedAmpDevOverviewEntry 7 }
|
|
|
|
speedAmpDevLosInputThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Loss of Input Power Threshold in units of 100*(value of 1dbm). Range: -45.00 to 0.00 dBm"
|
|
::= { speedAmpDevOverviewEntry 8 }
|
|
|
|
speedAmpDevHighOutputThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Output High Power Threshold in units of 100*(value of 1dbm)"
|
|
::= { speedAmpDevOverviewEntry 9 }
|
|
|
|
speedAmpDevAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
noAlarm (0),
|
|
unknown (254)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Alarm Status - Error code from amp module"
|
|
::= { speedAmpDevOverviewEntry 10 }
|
|
|
|
speedAmpDevCaseTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier module case temperature (value of 1degree Centigrade)"
|
|
::= { speedAmpDevOverviewEntry 11 }
|
|
|
|
speedAmpDevClientInputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier optical client Input Power in units of 100*(value of 1dbm)"
|
|
::= { speedAmpDevOverviewEntry 12 }
|
|
|
|
speedAmpDevLineOutputPower OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier optical line Output Power in units of 100*(value of 1dbm)"
|
|
::= { speedAmpDevOverviewEntry 13 }
|
|
|
|
speedAmpDevBackreflectionThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"this value is only available for RAMAN Amplifier"
|
|
::= { speedAmpDevOverviewEntry 14 }
|
|
|
|
|
|
speedAmpDevShutdownThreshold OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"this value is only available for RAMAN Amplifier"
|
|
::= { speedAmpDevOverviewEntry 15 }
|
|
|
|
|
|
speedAmpDevBackreflectionRatio OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"this value is only available for RAMAN Amplifier"
|
|
::= { speedAmpDevOverviewEntry 16 }
|
|
|
|
-- *********************************
|
|
-- SpeedAmpDeviceConfig
|
|
|
|
speedAmpDevConfigTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpDevConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Dev Config Table"
|
|
::= { speedAmp 11 }
|
|
|
|
speedAmpDevConfigEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpDevConfigEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Device Configuration Entries"
|
|
INDEX { speedAmpMSlot }
|
|
::= { speedAmpDevConfigTable 1 }
|
|
|
|
SpeedAmpDevConfigEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSlot INTEGER,
|
|
speedAmpDevCfgGainValue INTEGER,
|
|
speedAmpDevCfgPoutValue INTEGER,
|
|
speedAmpDevCfgPumpPwr INTEGER,
|
|
speedAmpDevCfgModeValue INTEGER,
|
|
speedAmpDevCfgPowerSafetyModeValue INTEGER,
|
|
speedAmpDevCfgLosInputThresholdValue INTEGER,
|
|
speedAmpDevCfgLinePortDescription DisplayString,
|
|
speedAmpDevCfgClientPortDescription DisplayString,
|
|
speedAmpDevCfgAlarmReporting INTEGER,
|
|
speedAmpDevCfgAlarmSchedule INTEGER,
|
|
speedAmpDevCfgBackreflectionThresholdValue INTEGER
|
|
}
|
|
|
|
speedAmpDevCfgGainValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier optical Gain Value in units of 100*(value of 1db)"
|
|
::= { speedAmpDevConfigEntry 3}
|
|
|
|
speedAmpDevCfgPoutValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Optical Output Power in units of 100*(value of 1dbm)"
|
|
::= { speedAmpDevConfigEntry 4}
|
|
|
|
speedAmpDevCfgPumpPwr OBJECT-TYPE
|
|
SYNTAX INTEGER (0..660)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Only applicable for RAMAN amplifiers. Pump power in
|
|
units of mW. For RAMAN-10 amplifiers the valid range
|
|
is 0..440 mW."
|
|
::= { speedAmpDevConfigEntry 5}
|
|
|
|
speedAmpDevCfgModeValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
confConstantPower(3),
|
|
confConstantGain(4),
|
|
confOFF(5),
|
|
confOther(6),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Working Mode"
|
|
::= { speedAmpDevConfigEntry 6}
|
|
|
|
speedAmpDevCfgPowerSafetyModeValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable (0),
|
|
cfgAutoLaserShutdownOff (1),
|
|
cfgAutoLaserShutdownOn (2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Power Safety Mode. On EDFA amplifiers an power shutdown will be forced, if the input threshold is blow the limit. On RAMAN modules the power will be reduced, if the backreflectioon is to high."
|
|
::= { speedAmpDevConfigEntry 7}
|
|
|
|
speedAmpDevCfgLosInputThresholdValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier optical Input Value LOS Threshold in units of 100*(value of 1dbm)"
|
|
::= { speedAmpDevConfigEntry 8}
|
|
|
|
speedAmpDevCfgLinePortDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Optical Line Port Description String "
|
|
::= { speedAmpDevConfigEntry 9}
|
|
|
|
speedAmpDevCfgClientPortDescription OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE (0..32))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Optical Client Port Description String "
|
|
::= { speedAmpDevConfigEntry 10}
|
|
|
|
speedAmpDevCfgAlarmReporting OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailable(0),
|
|
alarmReportingEnabled(1),
|
|
alarmReportingDisabledbySchedule(2),
|
|
alarmReportingDisabledPermanent(3),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amp module alarm deactivation"
|
|
::= { speedAmpDevConfigEntry 11 }
|
|
|
|
speedAmpDevCfgAlarmSchedule OBJECT-TYPE
|
|
SYNTAX INTEGER (0..1200)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amp module alarm deactivation schedule. Value in hours. After this time has elapsed, the alarms are active again."
|
|
::= { speedAmpDevConfigEntry 12 }
|
|
|
|
speedAmpDevCfgBackreflectionThresholdValue OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"this value is only available for RAMAN Amplifier"
|
|
::= { speedAmpDevConfigEntry 13 }
|
|
|
|
--***************************************
|
|
-- SpeedAmpDeviceAlarmTable
|
|
|
|
speedAmpDevAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpDevAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Amplifier device Alarm table"
|
|
::= { speedAmp 12 }
|
|
|
|
speedAmpDevAlarmEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpDevAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier device Alarm Entries"
|
|
INDEX { speedAmpMSlot }
|
|
::= { speedAmpDevAlarmTable 1 }
|
|
|
|
SpeedAmpDevAlarmEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSlot INTEGER,
|
|
speedAmpDevAlarmOpticalInput INTEGER,
|
|
speedAmpDevAlarmOpticalOutput INTEGER,
|
|
speedAmpDevAlarmModuleTemperature INTEGER,
|
|
speedAmpDevAlarmPumpTemperature INTEGER,
|
|
speedAmpDevAlarmPumpDriveCurrent INTEGER,
|
|
speedAmpDevAlarmSupplyVoltage INTEGER,
|
|
speedAmpDevAlarmAutoshutdown INTEGER,
|
|
speedAmpDevAlarmSecurityMonitor INTEGER,
|
|
speedAmpDevAlarmBackref INTEGER
|
|
}
|
|
|
|
speedAmpDevAlarmOpticalInput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable (0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier optical Input Value is under specified Threshold Value"
|
|
::= { speedAmpDevAlarmEntry 3 }
|
|
|
|
speedAmpDevAlarmOpticalOutput OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable (0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier optical Input Value is over specified Threshold Value"
|
|
::= { speedAmpDevAlarmEntry 4 }
|
|
|
|
speedAmpDevAlarmModuleTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable (0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Temperature Value is over specified Threshold Value"
|
|
::= { speedAmpDevAlarmEntry 5 }
|
|
|
|
speedAmpDevAlarmPumpTemperature OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable (0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Pump Temperature is out of specified Range"
|
|
::= { speedAmpDevAlarmEntry 6 }
|
|
|
|
speedAmpDevAlarmPumpDriveCurrent OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable (0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Pump Drive Current is out of specified Range"
|
|
::= { speedAmpDevAlarmEntry 7 }
|
|
|
|
speedAmpDevAlarmSupplyVoltage OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable (0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Supply voltage is out of specified Range"
|
|
::= { speedAmpDevAlarmEntry 8 }
|
|
|
|
speedAmpDevAlarmAutoshutdown OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable (0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Device Autoshutdown activated"
|
|
::= { speedAmpDevAlarmEntry 9 }
|
|
|
|
speedAmpDevAlarmSecurityMonitor OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable(0),
|
|
secmonready(1),
|
|
secmonhalted(2),
|
|
secmonfailure(3),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Status of SecurityMonitor"
|
|
::= { speedAmpDevAlarmEntry 10 }
|
|
|
|
speedAmpDevAlarmBackref OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable (0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown (255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Amplifier Device Alarm Backreflection"
|
|
::= { speedAmpDevAlarmEntry 11 }
|
|
|
|
--***************************************
|
|
-- SpeedAmpModuleSFPAlarmTable
|
|
|
|
speedAmpModuleSFPAlarmTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF SpeedAmpModuleSFPAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"SPEED-AMPLIFIER Module SFP Alarm table"
|
|
::= { speedAmp 13 }
|
|
|
|
speedAmpModuleSFPAlarmEntry OBJECT-TYPE
|
|
SYNTAX SpeedAmpModuleSFPAlarmEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module SFP Alarm Entries"
|
|
INDEX { speedAmpIndex }
|
|
::= { speedAmpModuleSFPAlarmTable 1 }
|
|
|
|
SpeedAmpModuleSFPAlarmEntry ::=
|
|
SEQUENCE
|
|
{
|
|
speedAmpMSFPSlot INTEGER,
|
|
speedAmpMSFPPort INTEGER,
|
|
speedAmpMSFPRxPowerAlarm INTEGER,
|
|
speedAmpMSFPTxPowerAlarm INTEGER,
|
|
speedAmpMSFPTxBiasAlarm INTEGER,
|
|
speedAmpMSFPTemperatureAlarm INTEGER,
|
|
speedAmpMSFPDWDMAlarm INTEGER
|
|
}
|
|
|
|
speedAmpMSFPRxPowerAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable(0),
|
|
noAlarm(1),
|
|
rxLowAlarm(2),
|
|
rxHighAlarm(3),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module SFP optical Rx Power is out of specified Range"
|
|
::= { speedAmpModuleSFPAlarmEntry 4 }
|
|
|
|
speedAmpMSFPTxPowerAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable(0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module SFP optical Tx Power is out of specified Range"
|
|
::= { speedAmpModuleSFPAlarmEntry 5 }
|
|
|
|
speedAmpMSFPTxBiasAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable(0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module SFP Bias Current is out of specified Range"
|
|
::= { speedAmpModuleSFPAlarmEntry 6 }
|
|
|
|
speedAmpMSFPTemperatureAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable(0),
|
|
noAlarm(1),
|
|
highWarning(2),
|
|
highAlarm(3),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Module SFP Temperature is out of specified Range"
|
|
::= { speedAmpModuleSFPAlarmEntry 7 }
|
|
|
|
speedAmpMSFPDWDMAlarm OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
{
|
|
notAvailiable(0),
|
|
noAlarm(1),
|
|
activeAlarm(2),
|
|
unknown(255)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DWDM SFP - DWDM Alarm"
|
|
::= { speedAmpModuleSFPAlarmEntry 8 }
|
|
|
|
|
|
END
|