Observium_CE/mibs/opengear/OG-OMTELEM-MIB

1113 lines
28 KiB
Plaintext

-- =====================================================================
-- == OG-OMSTATUS-MIB: ==
-- == Opengear Operation Manager Status Management Information Base ==
-- == ==
-- == (c) Copyright 2020 Opengear Inc. ==
-- =====================================================================
OG-OMTELEM-MIB DEFINITIONS ::= BEGIN
IMPORTS
ogMgmt
FROM OG-SMI-MIB
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
Counter32, Counter64, Integer32, MODULE-IDENTITY, OBJECT-TYPE
FROM SNMPv2-SMI
DateAndTime, DisplayString
FROM SNMPv2-TC;
ogOmTelem MODULE-IDENTITY
LAST-UPDATED "202311130934Z"
ORGANIZATION
"Opengear Inc."
CONTACT-INFO
"Opengear Inc.
630 West 9560 South, Suite A,
Sandy, UT 84070
support@opengear.com"
DESCRIPTION
"Opengear Operation Manager Telemetry MIB"
REVISION "202311130934Z"
DESCRIPTION
"Update Opengear Telemetry MIB for version 23.12.0.
- Add lteNr5g and nr5g enum values to accessTechnology leaf."
REVISION "202103121454Z"
DESCRIPTION
"added lastActiveTime to cell-uim submodule"
REVISION "202008041454Z"
DESCRIPTION
"Initial revision"
::= { ogMgmt 19 }
ogOmSystem OBJECT IDENTIFIER ::= { ogOmTelem 1 }
ogOmSystemHostName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current host name (if applicable)."
::= { ogOmSystem 1 }
ogOmSystemSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current serial number (if applicable)."
::= { ogOmSystem 2 }
ogOmSystemFirmwareVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current device firmware."
::= { ogOmSystem 3 }
ogOmSystemVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The device vendor."
::= { ogOmSystem 4 }
ogOmSystemModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The device model."
::= { ogOmSystem 5 }
ogOmSerialPort OBJECT IDENTIFIER ::= { ogOmTelem 2 }
ogOmSerialPortCount OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The number of serial ports"
::= { ogOmSerialPort 1 }
ogOmSerialPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Operations Manager Serial Port table structure."
::= { ogOmSerialPort 2 }
ogOmSerialPortEntry OBJECT-TYPE
SYNTAX SerialPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A serial port status table entry."
INDEX { ogOmSerialPortIndex }
::= { ogOmSerialPortTable 1 }
SerialPortEntry ::= SEQUENCE {
ogOmSerialPortIndex Integer32,
ogOmSerialPortLabel DisplayString,
ogOmSerialPortSpeed Integer32,
ogOmSerialPortDataBits Integer32,
ogOmSerialPortParity INTEGER,
ogOmSerialPortStopBits INTEGER,
ogOmSerialPortFlowControl INTEGER,
ogOmSerialPortMode INTEGER,
ogOmSerialPortPinout INTEGER,
ogOmSerialPortLogLevel INTEGER,
ogOmSerialPortRxBytes Counter64,
ogOmSerialPortTxBytes Counter64,
ogOmSerialPortFramingErrors Counter64,
ogOmSerialPortParityErrors Counter64,
ogOmSerialPortOverrunErrors Counter64,
ogOmSerialPortBreaks Counter64,
ogOmSerialPortDCD INTEGER,
ogOmSerialPortDTR INTEGER,
ogOmSerialPortDSR INTEGER,
ogOmSerialPortCTS INTEGER,
ogOmSerialPortRTS INTEGER
}
ogOmSerialPortIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the serial port table of this status"
::= { ogOmSerialPortEntry 1 }
ogOmSerialPortLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port descriptive name"
::= { ogOmSerialPortEntry 2 }
ogOmSerialPortSpeed OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port speed in bits per second"
::= { ogOmSerialPortEntry 3 }
ogOmSerialPortDataBits OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port character size"
::= { ogOmSerialPortEntry 4 }
ogOmSerialPortParity OBJECT-TYPE
SYNTAX INTEGER {
none(1),
odd(2),
even(3),
mark(4),
space(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port parity"
::= { ogOmSerialPortEntry 5 }
ogOmSerialPortStopBits OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
oneAndAHalf(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port number of stop bits"
::= { ogOmSerialPortEntry 6 }
ogOmSerialPortFlowControl OBJECT-TYPE
SYNTAX INTEGER {
none(1),
hardware(2),
software(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port flow control type"
::= { ogOmSerialPortEntry 7 }
ogOmSerialPortMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
localConsole(2),
consoleServer(3),
bridge(4),
terminalServer(5),
reserved(6),
pduDevice(7),
unknown(8)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port operational mode type"
::= { ogOmSerialPortEntry 8 }
ogOmSerialPortPinout OBJECT-TYPE
SYNTAX INTEGER {
x1(1),
x2(2),
usb(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port pinout type"
::= { ogOmSerialPortEntry 9 }
ogOmSerialPortLogLevel OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
connect(2),
inputAndOutput(3),
inputOnly(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port logging level"
::= { ogOmSerialPortEntry 10 }
ogOmSerialPortRxBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port bytes received"
::= { ogOmSerialPortEntry 11 }
ogOmSerialPortTxBytes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port bytes transmitted"
::= { ogOmSerialPortEntry 12 }
ogOmSerialPortFramingErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port framing error total."
::= { ogOmSerialPortEntry 13 }
ogOmSerialPortParityErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port parity error total."
::= { ogOmSerialPortEntry 14 }
ogOmSerialPortOverrunErrors OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port Overrun Error total."
::= { ogOmSerialPortEntry 15 }
ogOmSerialPortBreaks OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port break total"
::= { ogOmSerialPortEntry 16 }
ogOmSerialPortDCD OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DCD signal."
::= { ogOmSerialPortEntry 17 }
ogOmSerialPortDTR OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DTR signal."
::= { ogOmSerialPortEntry 18 }
ogOmSerialPortDSR OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the DSR signal."
::= { ogOmSerialPortEntry 19 }
ogOmSerialPortCTS OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the CTS signal."
::= { ogOmSerialPortEntry 20 }
ogOmSerialPortRTS OBJECT-TYPE
SYNTAX INTEGER {
unknown(0),
on(1),
off(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the RTS signal."
::= { ogOmSerialPortEntry 21 }
ogOmSerialUser OBJECT IDENTIFIER ::= { ogOmTelem 3 }
ogOmSerialUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF SerialUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Operations Manager Serial Console User table entry structure."
::= { ogOmSerialUser 1 }
ogOmSerialUserEntry OBJECT-TYPE
SYNTAX SerialUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user logged in on the serial port"
INDEX { ogOmSerialUserIndex }
::= { ogOmSerialUserTable 1 }
SerialUserEntry ::= SEQUENCE {
ogOmSerialUserIndex Integer32,
ogOmSerialUserStartTime DateAndTime,
ogOmSerialUserPortNumber Integer32,
ogOmSerialUserPortLabel DisplayString,
ogOmSerialUserName DisplayString
}
ogOmSerialUserIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the serial port active users table"
::= { ogOmSerialUserEntry 1 }
ogOmSerialUserStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The time and date the user session started."
::= { ogOmSerialUserEntry 2 }
ogOmSerialUserPortNumber OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Serial port number"
::= { ogOmSerialUserEntry 3 }
ogOmSerialUserPortLabel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The readable label for the serial port."
::= { ogOmSerialUserEntry 4 }
ogOmSerialUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the user logged in on the port."
::= { ogOmSerialUserEntry 5 }
ogOmWebUser OBJECT IDENTIFIER ::= { ogOmTelem 4 }
ogOmWebUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF WebUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Operations Manager Web UI User table structure."
::= { ogOmWebUser 1 }
ogOmWebUserEntry OBJECT-TYPE
SYNTAX WebUserEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A user logged in to the Web Interface"
INDEX { ogOmWebUserIndex }
::= { ogOmWebUserTable 1 }
WebUserEntry ::= SEQUENCE {
ogOmWebUserIndex Integer32,
ogOmWebUserStartTime DateAndTime,
ogOmWebUserName DisplayString,
ogOmWebUserSourceAddress DisplayString,
ogOmWebUserSourcePort Integer32
}
ogOmWebUserIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index within the Web Interface users table"
::= { ogOmWebUserEntry 1 }
ogOmWebUserStartTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The web users session start date and time."
::= { ogOmWebUserEntry 2 }
ogOmWebUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The web users active username."
::= { ogOmWebUserEntry 3 }
ogOmWebUserSourceAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The web users source address."
::= { ogOmWebUserEntry 4 }
ogOmWebUserSourcePort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The web users source tcp port."
::= { ogOmWebUserEntry 5 }
ogOmCellular OBJECT IDENTIFIER ::= { ogOmTelem 5 }
ogOmCellularTable OBJECT-TYPE
SYNTAX SEQUENCE OF CellularEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Operations Manager Cellular modem table structure."
::= { ogOmCellular 1 }
ogOmCellularEntry OBJECT-TYPE
SYNTAX CellularEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A cellular modem status entry."
INDEX { ogOmCellularIndex }
::= { ogOmCellularTable 1 }
CellularEntry ::= SEQUENCE {
ogOmCellularIndex Integer32,
ogOmCellularVendor DisplayString,
ogOmCellularModel DisplayString,
ogOmCellularEquipmentId DisplayString,
ogOmCellularFirmware DisplayString,
ogOmCellularState INTEGER,
ogOmCellularAccessTechnology INTEGER,
ogOmCellularActiveUim Counter32,
ogOmCellularUimFailoverState INTEGER
}
ogOmCellularIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the cellular modem status entry."
::= { ogOmCellularEntry 1 }
ogOmCellularVendor OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Manufacturer ID of Cellular Modem."
::= { ogOmCellularEntry 2 }
ogOmCellularModel OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Cellular Modem model name."
::= { ogOmCellularEntry 3 }
ogOmCellularEquipmentId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Cellular Modem Equipment Identifier (IMEI)."
::= { ogOmCellularEntry 4 }
ogOmCellularFirmware OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Cellular Modem firmware revision."
::= { ogOmCellularEntry 5 }
ogOmCellularState OBJECT-TYPE
SYNTAX INTEGER {
failed(1),
unknown(2),
initializing(3),
locked(4),
disabled(5),
disabling(6),
enabling(7),
enabled(8),
searching(9),
registered(10),
disconnecting(11),
connecting(12),
connected(13)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The overall current state of the modem."
::= { ogOmCellularEntry 6 }
ogOmCellularAccessTechnology OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
cdma(2),
evdo(3),
gsm(4),
umts(5),
lte(6),
gsmUmts(7),
gsmUmtsLte(8),
cdmaEvdo(9),
cdmaEvdoLte(10),
lteNr5g(11),
nr5g(12)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Radio Access Technology being used"
::= { ogOmCellularEntry 7 }
ogOmCellularActiveUim OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical UIM card slot number that is currently active."
::= { ogOmCellularEntry 8 }
ogOmCellularUimFailoverState OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
disabled(2),
enabled(3),
failingOver(4),
failedOver(5),
failingBack(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current UIM failover state"
::= { ogOmCellularEntry 9 }
ogOmCellUim OBJECT IDENTIFIER ::= { ogOmTelem 6 }
ogOmCellUimTable OBJECT-TYPE
SYNTAX SEQUENCE OF CellUimEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Operations Manager Cellular modem UIM table structure."
::= { ogOmCellUim 1 }
ogOmCellUimEntry OBJECT-TYPE
SYNTAX CellUimEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A cellular modem UIM status entry."
INDEX { ogOmCellUimIndex }
::= { ogOmCellUimTable 1 }
CellUimEntry ::= SEQUENCE {
ogOmCellUimIndex Integer32,
ogOmCellUimPhysicalSlot Counter32,
ogOmCellUimSlotState INTEGER,
ogOmCellUimCardState INTEGER,
ogOmCellUimIccid DisplayString,
ogOmCellUimImsi DisplayString,
ogOmCellUimOperatorName DisplayString,
ogOmCellUimApn DisplayString,
ogOmCellUimSignalQuality Integer32,
ogOmCellUimRssi Integer32,
ogOmCellUimConnectivityHealth INTEGER,
ogOmCellUimSignalHealth INTEGER,
ogOmCellUimLastUpdateTime DateAndTime,
ogOmCellUimLastActiveTime DateAndTime,
ogOmCellUimRoamingOperatorName DisplayString
}
ogOmCellUimIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the cellular modem UIM card."
::= { ogOmCellUimEntry 1 }
ogOmCellUimPhysicalSlot OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The physical UIM card slot number."
::= { ogOmCellUimEntry 2 }
ogOmCellUimSlotState OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
inactive(2),
active(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the Cellular Modem signal quality."
::= { ogOmCellUimEntry 3 }
ogOmCellUimCardState OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
absent(2),
present(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current UIM Card presence state."
::= { ogOmCellUimEntry 4 }
ogOmCellUimIccid OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The ICCID of the UIM card currently in use by this modem."
::= { ogOmCellUimEntry 5 }
ogOmCellUimImsi OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The IMSI of the UIM card currently in use by this modem."
::= { ogOmCellUimEntry 6 }
ogOmCellUimOperatorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the home network operator for this UIM card."
::= { ogOmCellUimEntry 7 }
ogOmCellUimApn OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The APN configured for this cellular modem UIM card."
::= { ogOmCellUimEntry 8 }
ogOmCellUimSignalQuality OBJECT-TYPE
SYNTAX Integer32 (0..100)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Signal quality as a percent of the dominant access technology the device is using to communicate with the network."
::= { ogOmCellUimEntry 9 }
ogOmCellUimRssi OBJECT-TYPE
SYNTAX Integer32 (-99..99)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Received Signal Strength Indicator (RSSI) for the current Radio Access Technology if applicable."
::= { ogOmCellUimEntry 10 }
ogOmCellUimConnectivityHealth OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
bad(2),
good(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the Cellular Modem connectivity testing."
::= { ogOmCellUimEntry 11 }
ogOmCellUimSignalHealth OBJECT-TYPE
SYNTAX INTEGER {
unavailable(1),
bad(2),
moderate(3),
good(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current state of the Cellular Modem signal quality."
::= { ogOmCellUimEntry 12 }
ogOmCellUimLastUpdateTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time of the last UIM card status check."
::= { ogOmCellUimEntry 13 }
ogOmCellUimLastActiveTime OBJECT-TYPE
SYNTAX DateAndTime
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The date and time of the last UIM card activation."
::= { ogOmCellUimEntry 14 }
ogOmCellUimRoamingOperatorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The name of the roaming network operator for this UIM card."
::= { ogOmCellUimEntry 15 }
ogOmEnrollment OBJECT IDENTIFIER ::= { ogOmTelem 7 }
ogOmEnrollmentTable OBJECT-TYPE
SYNTAX SEQUENCE OF EnrollmentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Operations Manager Lighthouse Enrollment table structure."
::= { ogOmEnrollment 1 }
ogOmEnrollmentEntry OBJECT-TYPE
SYNTAX EnrollmentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Lighthouse Enrollment status entry."
INDEX { ogOmEnrollmentIndex }
::= { ogOmEnrollmentTable 1 }
EnrollmentEntry ::= SEQUENCE {
ogOmEnrollmentIndex Integer32,
ogOmEnrollmentAddress DisplayString,
ogOmEnrollmentPort Integer32,
ogOmEnrollmentBundle DisplayString,
ogOmEnrollmentStatus INTEGER
}
ogOmEnrollmentIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the Lighthouse Enrollment status entry."
::= { ogOmEnrollmentEntry 1 }
ogOmEnrollmentAddress OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Lighthouse Enrollment address."
::= { ogOmEnrollmentEntry 2 }
ogOmEnrollmentPort OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Lighthouse Enrollment TCP port."
::= { ogOmEnrollmentEntry 3 }
ogOmEnrollmentBundle OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Lighthouse Enrollment bundle."
::= { ogOmEnrollmentEntry 4 }
ogOmEnrollmentStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
enrolling(2),
connected(3),
disconnected(4),
registered(5),
failed(6)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current Lighthouse Enrollment status."
::= { ogOmEnrollmentEntry 5 }
ogOmPowerSupply OBJECT IDENTIFIER ::= { ogOmTelem 8 }
ogOmPowerSupplyTable OBJECT-TYPE
SYNTAX SEQUENCE OF PowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Operations Manager Power Supply table structure."
::= { ogOmPowerSupply 1 }
ogOmPowerSupplyEntry OBJECT-TYPE
SYNTAX PowerSupplyEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Power Supply status entry."
INDEX { ogOmPowerSupplyIndex }
::= { ogOmPowerSupplyTable 1 }
PowerSupplyEntry ::= SEQUENCE {
ogOmPowerSupplyIndex Integer32,
ogOmPowerSupplyName DisplayString,
ogOmPowerSupplyDevice DisplayString,
ogOmPowerSupplyInputVoltage Integer32,
ogOmPowerSupplyOutputCurrent Integer32,
ogOmPowerSupplyOutputPower Integer32
}
ogOmPowerSupplyIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the power supply status entry."
::= { ogOmPowerSupplyEntry 1 }
ogOmPowerSupplyName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Power Supply name."
::= { ogOmPowerSupplyEntry 2 }
ogOmPowerSupplyDevice OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Power Supply device."
::= { ogOmPowerSupplyEntry 3 }
ogOmPowerSupplyInputVoltage OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 volts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Power Supply input voltage."
::= { ogOmPowerSupplyEntry 4 }
ogOmPowerSupplyOutputCurrent OBJECT-TYPE
SYNTAX Integer32
UNITS "0.001 Amps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Power Supply output current."
::= { ogOmPowerSupplyEntry 5 }
ogOmPowerSupplyOutputPower OBJECT-TYPE
SYNTAX Integer32
UNITS "Watts"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Power Supply output power."
::= { ogOmPowerSupplyEntry 6 }
ogOmTempSensor OBJECT IDENTIFIER ::= { ogOmTelem 9 }
ogOmTempSensorTable OBJECT-TYPE
SYNTAX SEQUENCE OF TempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Operations Manager Temperature Sensor table structure."
::= { ogOmTempSensor 1 }
ogOmTempSensorEntry OBJECT-TYPE
SYNTAX TempSensorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A Temperature Sensor status entry."
INDEX { ogOmTempSensorIndex }
::= { ogOmTempSensorTable 1 }
TempSensorEntry ::= SEQUENCE {
ogOmTempSensorIndex Integer32,
ogOmTempSensorName DisplayString,
ogOmTempSensorDevice DisplayString,
ogOmTempSensorValue Integer32
}
ogOmTempSensorIndex OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Index of the Temperature Sensor status entry."
::= { ogOmTempSensorEntry 1 }
ogOmTempSensorName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Temperature Sensor name."
::= { ogOmTempSensorEntry 2 }
ogOmTempSensorDevice OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Temperature Sensor device."
::= { ogOmTempSensorEntry 3 }
ogOmTempSensorValue OBJECT-TYPE
SYNTAX Integer32
UNITS "millidegrees Celsius"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Temperature Sensor value."
::= { ogOmTempSensorEntry 4 }
-- Conformance Information
ogOmConformance OBJECT IDENTIFIER ::= { ogOmTelem 65535 }
ogOmCompliances OBJECT IDENTIFIER ::= { ogOmConformance 1 }
ogOmGroups OBJECT IDENTIFIER ::= { ogOmConformance 2 }
-- Compliance Statements
ogOmCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for the ogOm MIB."
MODULE -- this module
MANDATORY-GROUPS {
ogOmBasicGroup
}
::= { ogOmCompliances 1 }
-- Units of Conformance
ogOmBasicGroup OBJECT-GROUP
OBJECTS {
ogOmSystemHostName,
ogOmSystemSerialNumber,
ogOmSystemFirmwareVersion,
ogOmSystemVendor,
ogOmSystemModel,
ogOmSerialPortCount,
ogOmSerialPortLabel,
ogOmSerialPortSpeed,
ogOmSerialPortDataBits,
ogOmSerialPortParity,
ogOmSerialPortStopBits,
ogOmSerialPortFlowControl,
ogOmSerialPortMode,
ogOmSerialPortPinout,
ogOmSerialPortLogLevel,
ogOmSerialPortRxBytes,
ogOmSerialPortTxBytes,
ogOmSerialPortFramingErrors,
ogOmSerialPortParityErrors,
ogOmSerialPortOverrunErrors,
ogOmSerialPortBreaks,
ogOmSerialPortDCD,
ogOmSerialPortDTR,
ogOmSerialPortDSR,
ogOmSerialPortCTS,
ogOmSerialPortRTS,
ogOmSerialUserStartTime,
ogOmSerialUserPortNumber,
ogOmSerialUserPortLabel,
ogOmSerialUserName,
ogOmWebUserStartTime,
ogOmWebUserName,
ogOmWebUserSourceAddress,
ogOmWebUserSourcePort,
ogOmCellularVendor,
ogOmCellularModel,
ogOmCellularEquipmentId,
ogOmCellularFirmware,
ogOmCellularState,
ogOmCellularAccessTechnology,
ogOmCellularActiveUim,
ogOmCellularUimFailoverState,
ogOmCellUimPhysicalSlot,
ogOmCellUimSlotState,
ogOmCellUimCardState,
ogOmCellUimIccid,
ogOmCellUimImsi,
ogOmCellUimOperatorName,
ogOmCellUimApn,
ogOmCellUimSignalQuality,
ogOmCellUimRssi,
ogOmCellUimConnectivityHealth,
ogOmCellUimSignalHealth,
ogOmCellUimLastUpdateTime,
ogOmCellUimLastActiveTime,
ogOmCellUimRoamingOperatorName,
ogOmEnrollmentAddress,
ogOmEnrollmentPort,
ogOmEnrollmentBundle,
ogOmEnrollmentStatus,
ogOmPowerSupplyName,
ogOmPowerSupplyDevice,
ogOmPowerSupplyInputVoltage,
ogOmPowerSupplyOutputCurrent,
ogOmPowerSupplyOutputPower,
ogOmTempSensorName,
ogOmTempSensorDevice,
ogOmTempSensorValue
}
STATUS current
DESCRIPTION
"A collection of ogOm related objects."
::= { ogOmGroups 1 }