617 lines
17 KiB
Plaintext
617 lines
17 KiB
Plaintext
-- *****************************
|
|
-- * *
|
|
-- * ONEOS MIB *
|
|
-- * *
|
|
-- *****************************
|
|
--
|
|
-- ONEOS_MIB_STD_V05.1.R005_E001
|
|
--
|
|
-- Creation date : 22/01/2003
|
|
--
|
|
-- Compatibility with ONEOS_V31
|
|
--
|
|
-- Compatibility with ONEOS_V32
|
|
--
|
|
|
|
|
|
|
|
ONEACCESS-OAM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY, OBJECT-TYPE,Counter32,Unsigned32,Integer32,IpAddress
|
|
FROM SNMPv2-SMI
|
|
DisplayString
|
|
FROM RFC1213-MIB
|
|
MODULE-COMPLIANCE, OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
TimeStamp,TimeInterval
|
|
FROM SNMPv2-TC
|
|
InterfaceIndex, ifIndex
|
|
FROM IF-MIB
|
|
atmVclEntry
|
|
FROM ATM-MIB
|
|
oacExpIMAtmOamStatistics,oacMIBModules
|
|
FROM ONEACCESS-GLOBAL-REG;
|
|
--
|
|
--
|
|
oacOamMIBModule MODULE-IDENTITY
|
|
LAST-UPDATED "201110270000Z"
|
|
ORGANIZATION " OneAccess "
|
|
CONTACT-INFO
|
|
"Pascal KESTELOOT
|
|
Postal: ONE ACCESS
|
|
381 Avenue du Général de Gaulle
|
|
92140 Clamart, France
|
|
FRANCE
|
|
|
|
Tel: (+33) 01 41 87 70 00
|
|
Fax: (+33) 01 41 87 74 00
|
|
|
|
E-mail: pascal.kesteloot@oneaccess-net.com"
|
|
|
|
DESCRIPTION
|
|
"Contact updated"
|
|
REVISION "201110270000Z"
|
|
|
|
DESCRIPTION
|
|
"Fixed Minor correction added last revision."
|
|
REVISION "201007080001Z"
|
|
|
|
DESCRIPTION
|
|
"This MIB module describes IP ACL Management objects."
|
|
|
|
::= { oacMIBModules 673 }
|
|
--
|
|
--
|
|
oacAtmOamStatObjects OBJECT IDENTIFIER ::= { oacExpIMAtmOamStatistics 1 }
|
|
oacAtmOamStatNotifications OBJECT IDENTIFIER ::= { oacExpIMAtmOamStatistics 2 }
|
|
oacAtmOamStatConformance OBJECT IDENTIFIER ::= { oacExpIMAtmOamStatistics 3 }
|
|
|
|
--
|
|
--
|
|
oacAtmOamStatSwitch OBJECT IDENTIFIER ::= { oacAtmOamStatObjects 1 }
|
|
|
|
oacAtmOamSwitchMaxConnections OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Maximum number of authorised OAM configured connections"
|
|
::= { oacAtmOamStatSwitch 1 }
|
|
|
|
oacAtmOamSwitchSegLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable segment loopback on this switch"
|
|
::= { oacAtmOamStatSwitch 2 }
|
|
|
|
oacAtmOamSwitchEndLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable end to end loopback on this switch"
|
|
::= { oacAtmOamStatSwitch 3 }
|
|
|
|
oacAtmOamSwitchAisRdiEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable Remote Defect Indication OAM cell generation
|
|
if an Alarm Indication Signal OAM cell is received, or if a
|
|
defect is detected on the switch"
|
|
::= { oacAtmOamStatSwitch 4 }
|
|
|
|
oacAtmOamSwitchSegmentContinuityCheckEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable Segment Loss of Continuity cells defect on the pvc.
|
|
Enable generation of segment Continuity Check cells on the switch."
|
|
::= { oacAtmOamStatSwitch 5 }
|
|
|
|
oacAtmOamSwitchEndContinuityCheckEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable End to End Loss of Continuity cells defect on the pvc.
|
|
Enable generation of End to End Continuity Check cells on the switch."
|
|
::= { oacAtmOamStatSwitch 6 }
|
|
|
|
oacAtmOamSwitchOamCellsReceived OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received OAM cells on the switch"
|
|
::= { oacAtmOamStatSwitch 7 }
|
|
|
|
oacAtmOamSwitchOamCellsTransmitted OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of transmitted OAM cells on the switch"
|
|
::= { oacAtmOamStatSwitch 8 }
|
|
|
|
oacAtmOamSwitchCurrentConnections OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Current number of OAM configured connections"
|
|
::= { oacAtmOamStatSwitch 9 }
|
|
|
|
|
|
|
|
--
|
|
--
|
|
|
|
oacAtmOamVclTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OacAtmOamVclEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index into the table oacAtmOamVclTable"
|
|
::= { oacAtmOamStatObjects 2 }
|
|
|
|
oacAtmOamVclEntry OBJECT-TYPE
|
|
SYNTAX OacAtmOamVclEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index into the table oacAtmOamVclTable"
|
|
AUGMENTS {atmVclEntry}
|
|
::= { oacAtmOamVclTable 1 }
|
|
|
|
OacAtmOamVclEntry ::= SEQUENCE {
|
|
oacAtmOamVclPvcManage INTEGER,
|
|
oacAtmOamVclSegmentLoopback INTEGER,
|
|
oacAtmOamVclEndLoopback INTEGER,
|
|
oacAtmOamVclAisRdiEnable INTEGER,
|
|
oacAtmOamVclSegmentContinuityCheckEnable INTEGER,
|
|
oacAtmOamVclEndContinuityCheckEnable INTEGER,
|
|
oacAtmOamVclLoopbackTxInterval Integer32,
|
|
oacAtmOamVclLoopbackTxRetryFrequency Integer32,
|
|
oacAtmOamVclLoopbackTxRetryUpCount Integer32,
|
|
oacAtmOamVclLoopbackTxRetryDownCount Integer32,
|
|
oacAtmOamVclAlarmState Integer32,
|
|
oacAtmOamVclAlarmStateLastChange TimeStamp,
|
|
oacAtmOamVclAisRdiRetryDownCount Integer32,
|
|
oacAtmOamVclAisRdiRetryUpTimer Integer32,
|
|
oacAtmOamVclPvcIntrusive INTEGER
|
|
}
|
|
|
|
oacAtmOamVclPvcManage OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable OAM for Pvc management"
|
|
::= { oacAtmOamVclEntry 1 }
|
|
|
|
oacAtmOamVclSegmentLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable segment loopback on this virtual channel"
|
|
::= { oacAtmOamVclEntry 2 }
|
|
|
|
oacAtmOamVclEndLoopback OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable end to end loopback on this virtual channel"
|
|
::= { oacAtmOamVclEntry 3 }
|
|
|
|
oacAtmOamVclAisRdiEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable Remote Defect Indication
|
|
OAM cell generation if an Alarm
|
|
Indication Signal OAM cell is received,
|
|
or if a defect is detected on the PVC"
|
|
::= { oacAtmOamVclEntry 4 }
|
|
|
|
oacAtmOamVclSegmentContinuityCheckEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable Segment Loss of Continuity
|
|
cells detect on the PVC.Enable generation of
|
|
Segment Continuity Check
|
|
cells on the PVC."
|
|
::= { oacAtmOamVclEntry 5 }
|
|
|
|
oacAtmOamVclEndContinuityCheckEnable OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable End to End Loss of Continuity
|
|
cells detect on the PVC.Enable generation of
|
|
End to End Continuity Check
|
|
cells on the PVC."
|
|
::= { oacAtmOamVclEntry 6 }
|
|
|
|
|
|
oacAtmOamVclLoopbackTxInterval OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Frequency of OAM loopback cell
|
|
are generated on this virtual channel"
|
|
::= { oacAtmOamVclEntry 7}
|
|
|
|
oacAtmOamVclLoopbackTxRetryFrequency OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Frequency of OAM loopback cell
|
|
are generated on this virtual channel,
|
|
when a change has occured, that is to
|
|
say either no reception of the last
|
|
loopback cell, or reception of the
|
|
last loopback cell"
|
|
::= { oacAtmOamVclEntry 8}
|
|
|
|
oacAtmOamVclLoopbackTxRetryUpCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Counter of consecutive received loopback cells,
|
|
before vcl is considered as being up"
|
|
::= { oacAtmOamVclEntry 9}
|
|
|
|
oacAtmOamVclLoopbackTxRetryDownCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Counter of consecutive non received loopback cells,
|
|
before vcl is considered as being down"
|
|
::= { oacAtmOamVclEntry 10}
|
|
|
|
|
|
oacAtmOamVclAlarmState OBJECT-TYPE
|
|
SYNTAX Integer32 MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" This object indicates the current
|
|
alarm status of the VCL, when error monitoring
|
|
is activated on the VCL. Value indicates
|
|
the different alarm states tha the VCL can take.
|
|
Those alarms can be combined together.
|
|
The unknown state indicates that the
|
|
alarm status of this VCL cannot be determined.
|
|
cc_seg_loc(1),cc_ete_loc(2),
|
|
lb_seg_alarm(4),lb_ete_alarm(8),
|
|
ais_alarm(16),rdi_alarm(32),other(64)"
|
|
::= { oacAtmOamVclEntry 11 }
|
|
|
|
oacAtmOamVclAlarmStateLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" The value of sysUpTime object at the time this VCL
|
|
entered its current alarm status. If the current state
|
|
was entered prior to the last re-initialization of the
|
|
agent, then this object contains a zero value."
|
|
::= { oacAtmOamVclEntry 12}
|
|
|
|
oacAtmOamVclAisRdiRetryDownCount OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of consecutive OAM AIS/RDI cells received.
|
|
The range is 3 to 60. The default is 3."
|
|
::= { oacAtmOamVclEntry 13}
|
|
|
|
oacAtmOamVclAisRdiRetryUpTimer OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of seconds with no OAM AIS/RDI cells received.
|
|
The range is 3 to 60 seconds . The default is 3 seconds."
|
|
::= { oacAtmOamVclEntry 14}
|
|
|
|
oacAtmOamVclPvcIntrusive OBJECT-TYPE
|
|
SYNTAX INTEGER { enable(1),disable(2)}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Enable OAM Intrusivity against Pvc"
|
|
::= { oacAtmOamVclEntry 15 }
|
|
--
|
|
--
|
|
|
|
oacAtmOamVclCountersTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF OacAtmOamVclCountersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index into table oacAtmOamVclCountersTable"
|
|
::= { oacAtmOamStatObjects 3 }
|
|
|
|
oacAtmOamVclCountersEntry OBJECT-TYPE
|
|
SYNTAX OacAtmOamVclCountersEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An index into table oacAtmOamVclCountersTable"
|
|
AUGMENTS {atmVclEntry}
|
|
::= { oacAtmOamVclCountersTable 1 }
|
|
|
|
OacAtmOamVclCountersEntry ::= SEQUENCE {
|
|
oacAtmOamVclOamCellsReceived Counter32,
|
|
oacAtmOamVclEndLoopbackIn Counter32,
|
|
oacAtmOamVclSegLoopbackIn Counter32,
|
|
oacAtmOamVclEndLoopIn Counter32,
|
|
oacAtmOamVclSegLoopIn Counter32,
|
|
oacAtmOamVclAisIn Counter32,
|
|
oacAtmOamVclRdiIn Counter32,
|
|
oacAtmOamVclSegCCIn Counter32,
|
|
oacAtmOamVclEndCCIn Counter32,
|
|
oacAtmOamVclOamCellsSent Counter32,
|
|
oacAtmOamVclEndLoopbackOut Counter32,
|
|
oacAtmOamVclSegLoopbackOut Counter32,
|
|
oacAtmOamVclEndLoopOut Counter32,
|
|
oacAtmOamVclSegLoopOut Counter32,
|
|
oacAtmOamVclAisOut Counter32,
|
|
oacAtmOamVclRdiOut Counter32,
|
|
oacAtmOamVclSegCCOut Counter32,
|
|
oacAtmOamVclEndCCOut Counter32,
|
|
oacAtmOamVclOamCellsDropped Counter32
|
|
}
|
|
|
|
oacAtmOamVclOamCellsReceived OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received oam cells"
|
|
::= { oacAtmOamVclCountersEntry 1 }
|
|
|
|
oacAtmOamVclEndLoopbackIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received non looped
|
|
end to end oam loopback cells "
|
|
::= { oacAtmOamVclCountersEntry 2 }
|
|
|
|
oacAtmOamVclSegLoopbackIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received non looped
|
|
segment oam loopback cells"
|
|
::= { oacAtmOamVclCountersEntry 3 }
|
|
|
|
oacAtmOamVclEndLoopIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received looped end
|
|
to end oam loopback cells"
|
|
::= { oacAtmOamVclCountersEntry 4 }
|
|
|
|
oacAtmOamVclSegLoopIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received looped segment
|
|
oam loopback cells"
|
|
::= { oacAtmOamVclCountersEntry 5 }
|
|
|
|
|
|
oacAtmOamVclAisIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received oam ais cells"
|
|
::= { oacAtmOamVclCountersEntry 6 }
|
|
|
|
oacAtmOamVclRdiIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received oam rdi cells"
|
|
::= { oacAtmOamVclCountersEntry 7 }
|
|
|
|
oacAtmOamVclSegCCIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received oam end to end continuity check cells"
|
|
::= { oacAtmOamVclCountersEntry 8 }
|
|
|
|
oacAtmOamVclEndCCIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received oam segment continuity check cells"
|
|
::= { oacAtmOamVclCountersEntry 9 }
|
|
|
|
oacAtmOamVclOamCellsSent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent oam cells"
|
|
::= { oacAtmOamVclCountersEntry 10 }
|
|
|
|
oacAtmOamVclEndLoopbackOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent non looped end to end oam loopback cells "
|
|
::= { oacAtmOamVclCountersEntry 11 }
|
|
|
|
oacAtmOamVclSegLoopbackOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent non looped segment oam loopback cells"
|
|
::= { oacAtmOamVclCountersEntry 12 }
|
|
|
|
oacAtmOamVclEndLoopOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent looped end to end oam loopback cells"
|
|
::= { oacAtmOamVclCountersEntry 13 }
|
|
|
|
oacAtmOamVclSegLoopOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent looped segment oam loopback cells"
|
|
::= { oacAtmOamVclCountersEntry 14 }
|
|
|
|
|
|
oacAtmOamVclAisOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent oam ais cells"
|
|
::= { oacAtmOamVclCountersEntry 15 }
|
|
|
|
oacAtmOamVclRdiOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent oam rdi cells"
|
|
::= { oacAtmOamVclCountersEntry 16 }
|
|
|
|
oacAtmOamVclSegCCOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent oam end to end continuity check cells"
|
|
::= { oacAtmOamVclCountersEntry 17 }
|
|
|
|
oacAtmOamVclEndCCOut OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of sent oam segment continuity check cells "
|
|
::= { oacAtmOamVclCountersEntry 18 }
|
|
|
|
oacAtmOamVclOamCellsDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
" Number of received oam cells that are ignored and dropped"
|
|
::= { oacAtmOamVclCountersEntry 19 }
|
|
|
|
|
|
|
|
--
|
|
--
|
|
|
|
oacAtmOamStatGroups OBJECT IDENTIFIER ::= { oacAtmOamStatConformance 1}
|
|
|
|
|
|
oacAtmOamStatCompliances OBJECT IDENTIFIER ::= { oacAtmOamStatConformance 2}
|
|
|
|
oacAtmOamStatCompliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for agents that support the
|
|
ONEACCESS-OAM-MIB."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS { oacAtmOamStatGeneralGroup
|
|
}
|
|
|
|
::= { oacAtmOamStatCompliances 1}
|
|
|
|
oacAtmOamStatGeneralGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
oacAtmOamSwitchMaxConnections,
|
|
oacAtmOamSwitchSegLoopback,
|
|
oacAtmOamSwitchEndLoopback,
|
|
oacAtmOamSwitchAisRdiEnable,
|
|
oacAtmOamSwitchSegmentContinuityCheckEnable,
|
|
oacAtmOamSwitchEndContinuityCheckEnable,
|
|
oacAtmOamSwitchOamCellsReceived,
|
|
oacAtmOamSwitchOamCellsTransmitted,
|
|
oacAtmOamSwitchCurrentConnections,
|
|
oacAtmOamVclPvcManage ,
|
|
oacAtmOamVclSegmentLoopback ,
|
|
oacAtmOamVclEndLoopback ,
|
|
oacAtmOamVclAisRdiEnable ,
|
|
oacAtmOamVclSegmentContinuityCheckEnable ,
|
|
oacAtmOamVclEndContinuityCheckEnable ,
|
|
oacAtmOamVclLoopbackTxInterval ,
|
|
oacAtmOamVclLoopbackTxRetryFrequency ,
|
|
oacAtmOamVclLoopbackTxRetryUpCount ,
|
|
oacAtmOamVclLoopbackTxRetryDownCount ,
|
|
oacAtmOamVclAlarmState ,
|
|
oacAtmOamVclAlarmStateLastChange ,
|
|
oacAtmOamVclAisRdiRetryDownCount ,
|
|
oacAtmOamVclAisRdiRetryUpTimer ,
|
|
oacAtmOamVclPvcIntrusive ,
|
|
oacAtmOamVclOamCellsReceived ,
|
|
oacAtmOamVclEndLoopbackIn ,
|
|
oacAtmOamVclSegLoopbackIn ,
|
|
oacAtmOamVclEndLoopIn ,
|
|
oacAtmOamVclSegLoopIn ,
|
|
oacAtmOamVclAisIn ,
|
|
oacAtmOamVclRdiIn ,
|
|
oacAtmOamVclSegCCIn ,
|
|
oacAtmOamVclEndCCIn ,
|
|
oacAtmOamVclOamCellsSent ,
|
|
oacAtmOamVclEndLoopbackOut ,
|
|
oacAtmOamVclSegLoopbackOut ,
|
|
oacAtmOamVclEndLoopOut ,
|
|
oacAtmOamVclSegLoopOut ,
|
|
oacAtmOamVclAisOut ,
|
|
oacAtmOamVclRdiOut ,
|
|
oacAtmOamVclSegCCOut ,
|
|
oacAtmOamVclEndCCOut ,
|
|
oacAtmOamVclOamCellsDropped
|
|
}
|
|
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This group is mandatory for all OAM entities."
|
|
::= { oacAtmOamStatGroups 1 }
|
|
|
|
|
|
END
|
|
--
|