Observium_CE/mibs/nortel/RC-SLPP-MIB

496 lines
17 KiB
Plaintext

RC-SLPP-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, Integer32, NOTIFICATION-TYPE,
Unsigned32
FROM SNMPv2-SMI
TruthValue, MacAddress, RowStatus
FROM SNMPv2-TC
InterfaceIndex
FROM IF-MIB
rcSlpp, PortSet
FROM RAPID-CITY;
rcSlppMib MODULE-IDENTITY
LAST-UPDATED "202011120000Z"
ORGANIZATION "Bay Networks, Rapid-City Group"
CONTACT-INFO "Yu-Ten Lee
Postal: Nortel Networks, Inc.
4655 Great America Parkway
Santa Clara, CA 95052-8185
Tel: 408-495-2560
Fax: 408-495-6680
E-mail: ylee@nortelnetworks.com"
DESCRIPTION "Enterprise MIB for SLPP"
REVISION "202011120000Z" -- 12 Nov 2020
DESCRIPTION "Version 18: Correct BITS range to start from 0 for rcSlppPortGuardOrigin"
REVISION "202011020000Z" -- 02 Nov 2020
DESCRIPTION "Version 17: Added rcSlppPortGuardOrigin"
REVISION "201210080000Z" -- 08 October 2012
DESCRIPTION "Version 16: Changed default value for rcSlppEtherType from '8104'h to '8102'h"
REVISION "201110060000Z" -- 06 October 2011
DESCRIPTION "Version 15: Added rcSlppPortTimeToClrPktRxCount,
rcSlppPortRemainingTimeToClrPktRxCount,
rcSlppPortClearPktRxCount."
REVISION "201011100000Z" -- 10 November 2010
DESCRIPTION "Version 14: Added rcSlppPortGuardStatus,
rcSlppPortGuardTimerCount,
rcSlppGuardPortIfIndex."
REVISION "201010120000Z" -- 12 October 2010
DESCRIPTION "Version 13: Additional support for slpp guard feature."
REVISION "201009280000Z" -- 28 September 2010
DESCRIPTION "Version 12: Added support for slpp guard feature."
REVISION "200911090000Z" -- 09 November 2009
DESCRIPTION "Version 11: Added rcnSlppLoopOnDiffVlan."
REVISION "200806180001Z" -- 18 Jun 2008
DESCRIPTION "Version 10: Added rcSlppUniPorts, rcSlppPortPktRxCount.
Added range for rcSlppEtherType."
REVISION "200806180000Z" -- 18 Jun 2008
DESCRIPTION "Version 9: Change rcSlppPortPktRxThreshold in SEQUENCE of
RcSlppPortEntry SYNTAX from INTEGER to Integer32."
REVISION "200708240000Z" -- 24 August 2007
DESCRIPTION "Version 8: Added rcSlppTimeout."
REVISION "200606040000Z" -- 04 June 2006
DESCRIPTION "Version 7: Added rcnSlppPortDownEventNew and two new notification objects."
REVISION "200605010000Z" -- 01 May 2006
DESCRIPTION "Version 6: Updated rcSlppPortPktRxThreshold and rcSlppPortSlppEnable to have
DEFVAL. Update made on behalf of Yi Zhang, ERS8600 submit #9468."
REVISION "200604280000Z" -- 28 April 2006
DESCRIPTION "Version 5: Updated rcSlppPortPktRxThreshold to read Integer32 (1..500).
Update made on behalf of Yi Zhang, ERS8600 submit #9240."
REVISION "200603300000Z" -- 30 March 2006
DESCRIPTION "Version 4: Added rcSlppPortIncomingVlanId and rcSlppPortSrcNodeType.
Update made on behalf of Yi Zhang, ERS8600 submit #8286."
REVISION "200603160000Z" -- 16 March 2006
DESCRIPTION "Version 3: Updated rcSlppPortPktRxThreshold to read Integer32 (1..20).
Update made on behalf of Yi Zhang, ERS8600 submit #8198."
REVISION "200508300000Z" -- 30 Aug 2005
DESCRIPTION "Version 2: Added rcSlppPortSlppEnable and RowStatus to the vlan
and port tables. Also, updated the range for objects rcSlppTransmissionInterval and
rcSlppPortPktRxThreshold."
REVISION "200507290000Z" -- 29 July 2005
DESCRIPTION "Version 1: Initial version"
::= { rcSlpp 1 }
rcSlppNotifications OBJECT IDENTIFIER ::= { rcSlppMib 0 }
rcSlppObjects OBJECT IDENTIFIER ::= { rcSlppMib 1 }
rcSlppNotificationObjects OBJECT IDENTIFIER ::= { rcSlppMib 2 }
-- --------------------------------------------------
-- Scalar Objects
-- --------------------------------------------------
rcSlppScalars OBJECT IDENTIFIER ::= { rcSlppObjects 1 }
rcSlppGlobalEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Global enable/disable for the simple loop prevention protocol."
DEFVAL { false }
::= { rcSlppScalars 1 }
rcSlppTransmissionInterval OBJECT-TYPE
SYNTAX Integer32 (500..5000)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "The interval (in milliseconds) for which loop detection occurs."
DEFVAL { 500 }
::= { rcSlppScalars 2 }
rcSlppEtherType OBJECT-TYPE
SYNTAX Integer32(1..'FFFF'h)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SLPP Protocol Identification. The value is normally in Hex."
DEFVAL { '8102'h }
::= { rcSlppScalars 3 }
rcSlppTimeout OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This value specifies the time period for which a port
will remain disabled. When SLPP disables a port, after
this time period expires, the port will become
re-enabled. A value of 0 means ports will never
be re-enabled."
DEFVAL { 0 }
::= { rcSlppScalars 4 }
rcSlppUniPorts OBJECT-TYPE
SYNTAX PortSet
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Contains UNI ports added under SLPP global config"
::= { rcSlppScalars 5 }
rcSlppGuardEtherType OBJECT-TYPE
SYNTAX Integer32(1..'FFFF'h)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "SLPP Guard ether type."
DEFVAL { '8102'h }
::= { rcSlppScalars 6 }
-- --------------------------------------------------
-- rcSlppVlanTable
-- --------------------------------------------------
rcSlppVlanTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlppVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of VLANs for which simple loop detection occur on."
::= { rcSlppObjects 2 }
rcSlppVlanEntry OBJECT-TYPE
SYNTAX RcSlppVlanEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "SLPP VLAN entry. "
INDEX { rcSlppVlanVlanId }
::= { rcSlppVlanTable 1 }
RcSlppVlanEntry ::= SEQUENCE {
rcSlppVlanVlanId Integer32,
rcSlppVlanSlppEnable TruthValue,
rcSlppVlanRowStatus RowStatus
}
rcSlppVlanVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Vlan id for which simple loop detection occurs on."
::= { rcSlppVlanEntry 1 }
rcSlppVlanSlppEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Flag to indicate whether the VLAN entry is active or not for SLPP."
::= { rcSlppVlanEntry 2 }
rcSlppVlanRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to create/delete entries."
::= { rcSlppVlanEntry 3}
-- --------------------------------------------------
-- rcSlppPortTable
-- --------------------------------------------------
rcSlppPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF RcSlppPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Table of ports for which simple loop detection occurs on."
::= { rcSlppObjects 3 }
rcSlppPortEntry OBJECT-TYPE
SYNTAX RcSlppPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "SLPP Port entry. "
INDEX { rcSlppPortIfIndex }
::= { rcSlppPortTable 1 }
RcSlppPortEntry ::= SEQUENCE {
rcSlppPortIfIndex InterfaceIndex,
rcSlppPortPktRxThreshold Integer32,
rcSlppPortSlppEnable TruthValue,
rcSlppPortRowStatus RowStatus,
rcSlppPortIncomingVlanId Integer32,
rcSlppPortSrcNodeType INTEGER,
rcSlppPortPktRxCount Integer32,
rcSlppPortGuardEnable TruthValue,
rcSlppPortGuardTimeout Integer32,
rcSlppPortGuardStatus INTEGER,
rcSlppPortGuardTimerCount Integer32,
rcSlppPortTimeToClrPktRxCount Unsigned32,
rcSlppPortRemainingTimeToClrPktRxCount Unsigned32,
rcSlppPortClearPktRxCount TruthValue,
rcSlppPortGuardOrigin BITS
}
rcSlppPortIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Port on which simple loop detection occurs on."
::= { rcSlppPortEntry 1 }
rcSlppPortPktRxThreshold OBJECT-TYPE
SYNTAX Integer32 (1..500)
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Once the number of SLPP packets received on this port reaches this threshold
action will be taken. Normally, the port will be shutdown."
DEFVAL { 1 }
::= { rcSlppPortEntry 2 }
rcSlppPortSlppEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION "Flag to indicate whether the port entry is active or not for SLPP."
DEFVAL { false }
::= { rcSlppPortEntry 3 }
rcSlppPortRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION "Used to create/delete entries."
::= { rcSlppPortEntry 4 }
rcSlppPortIncomingVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Vlan id of the classified packet on the port brought down by
SLPP."
::= { rcSlppPortEntry 5 }
rcSlppPortSrcNodeType OBJECT-TYPE
SYNTAX INTEGER {
none(0),
local(1),
peer(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The src node type of the received slpp Pkt."
::= { rcSlppPortEntry 6 }
rcSlppPortPktRxCount OBJECT-TYPE
SYNTAX Integer32 (1..500)
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Total number of SLPP packets received on the port"
::= { rcSlppPortEntry 7 }
rcSlppPortGuardEnable OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Flag to indicate if SLPP-guard is enabled on the port."
::= { rcSlppPortEntry 8 }
rcSlppPortGuardTimeout OBJECT-TYPE
SYNTAX Integer32 (0|10..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This value specifies the time period for which a port will remain
disabled. When SLPP-guard disables a port, after this time period
expires, the port will become re-enabled. A value of 0 means ports
will never be re-enabled."
::= { rcSlppPortEntry 9 }
rcSlppPortGuardStatus OBJECT-TYPE
SYNTAX INTEGER {
none(1),
monitoring(2),
blocking(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The object indicates the SLPP-guard status of a port."
::= { rcSlppPortEntry 10 }
rcSlppPortGuardTimerCount OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This value specifies the time period that has passed since
a port was administratively disabled by SLPP-guard. When this
object reaches the timeout value (rcSlppPortGuardTimeout),
the port will become re-enabled."
::= { rcSlppPortEntry 11 }
rcSlppPortTimeToClrPktRxCount OBJECT-TYPE
SYNTAX Unsigned32 (1..86400)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Time to clear the SLPP Rx PDU counter. This has a
maximum value of 86400 seconds. The timer starts
when SLPP is enabled and port starts receiving SLPP
SLPP PDUs. When the time exceeds this configured value,
the SLPP Pkt Rx Count will be reset."
::= { rcSlppPortEntry 12 }
rcSlppPortRemainingTimeToClrPktRxCount OBJECT-TYPE
SYNTAX Unsigned32 (1..86400)
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Remaining time to clear the SLPP Rx PDU counter."
::= { rcSlppPortEntry 13 }
rcSlppPortClearPktRxCount OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Clear the SLPP Rx PDU counter."
::= { rcSlppPortEntry 14 }
rcSlppPortGuardOrigin OBJECT-TYPE
SYNTAX BITS {
config(0),
radius(1)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Indicates how slpp guard was configured.
Supported values:
config - set by user
radius - set by radius atribute"
::= { rcSlppPortEntry 15 }
-- --------------------------------------------------
-- Notification Objects
-- --------------------------------------------------
rcSlppIncomingVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Vlan id of the classified packet on the port brought down by SLPP."
::= { rcSlppNotificationObjects 1 }
rcSlppSrcMacAddress OBJECT-TYPE
SYNTAX MacAddress
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION
"Source MAC address in the classified packet on the port brought
down by SLPP."
::= { rcSlppNotificationObjects 2 }
rcSlppRxPortIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Port on which the SLPP packet is received."
::= { rcSlppNotificationObjects 3 }
rcSlppRxVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Vlan on which the SLPP packet is received."
::= { rcSlppNotificationObjects 4 }
rcSlppTxVlanId OBJECT-TYPE
SYNTAX Integer32 (1..4094)
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Vlan on which the SLPP packet is sent."
::= { rcSlppNotificationObjects 5 }
rcSlppGuardPortIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS accessible-for-notify
STATUS current
DESCRIPTION "Port on which the SLPP-guard packet is received."
::= { rcSlppNotificationObjects 6 }
-- ----------------------------------------------
-- Notifications
-- ----------------------------------------------
rcnSlppPortDownEvent NOTIFICATION-TYPE
OBJECTS { rcSlppPortSlppEnable,
rcSlppVlanSlppEnable,
rcSlppIncomingVlanId,
rcSlppSrcMacAddress }
STATUS obsolete
DESCRIPTION
"A port down event that has occurred due to SLPP. The user is
notified of the expected Vlan ID along with the Vlan ID and source
MAC address of the packet coming in on the port identified. The
first two objects can be used to lookup instance info for port id
and vlan id."
::= { rcSlppNotifications 1 }
rcnSlppPortDownEventNew NOTIFICATION-TYPE
OBJECTS { rcSlppRxPortIndex,
rcSlppRxVlanId,
rcSlppIncomingVlanId,
rcSlppSrcMacAddress }
STATUS current
DESCRIPTION
"A port down event that has occurred due to SLPP. The trap
includes the port and its Vlan which receives the packet, and
along with the Vlan ID and source MAC address of the packet coming in
on the port identified."
::= { rcSlppNotifications 2 }
rcnSlppLoopOnDiffVlan NOTIFICATION-TYPE
OBJECTS { rcSlppRxPortIndex,
rcSlppRxVlanId,
rcSlppTxVlanId,
rcSlppSrcMacAddress }
STATUS current
DESCRIPTION
"Indicates SLPP received its own packet but with the TX VLAN not
equal to the RX VLAN."
::= { rcSlppNotifications 3 }
rcnSlppGuardHoldDownExpired NOTIFICATION-TYPE
OBJECTS { rcSlppGuardPortIfIndex }
STATUS current
DESCRIPTION
"Indicates that the SLPP-guard hold-down timer has expired on a port
on which SLPP-guard is enabled, and the port has been re-enabled."
::= { rcSlppNotifications 4 }
rcnSlppGuardPacketReceived NOTIFICATION-TYPE
OBJECTS { rcSlppGuardPortIfIndex }
STATUS current
DESCRIPTION
"Indicates an SLPP packet has been received on a port on which
SLPP-guard is enabled. The port has been disabled."
::= { rcSlppNotifications 5 }
END