Observium_CE/mibs/nortel/NORTEL-OME40G-PRTN-MIB

254 lines
4.8 KiB
Plaintext

NORTEL-OME40G-PRTN-MIB DEFINITIONS ::= BEGIN
IMPORTS
nnOme40G FROM NORTEL-OME40G-MIB
DisplayString FROM RFC1213-MIB
RowStatus FROM SNMPv2-TC
ifIndex FROM IF-MIB
InterfaceIndex FROM IF-MIB
entPhysicalIndex FROM ENTITY-MIB
MODULE-IDENTITY,
OBJECT-TYPE,
OBJECT-IDENTITY FROM SNMPv2-SMI;
nnOme40GProtection MODULE-IDENTITY
LAST-UPDATED "200802070000Z"
ORGANIZATION "Nortel"
CONTACT-INFO
" 7035 Ridge Road
Hanover, Maryland 21076
United States
Toll-free: +1-800-921-1144
Phone: +1-410-694-5700
Fax: +1-410-694-5750
www.ciena.com "
DESCRIPTION
"Optical Multiservice Edge (ome)
This Module is for 40G protection"
--Revision history
REVISION "200702020000Z"
DESCRIPTION "Initial Version - created for OME6500 REL 5.1"
REVISION "200802070000Z"
DESCRIPTION "Updating row formatting OME6500 REL 5.11"
::= { nnOme40G 3 }
nnOme40Gotm3Protection OBJECT IDENTIFIER ::= { nnOme40GProtection 1 }
nnOTM3protectionGroupTable OBJECT-TYPE
SYNTAX SEQUENCE OF NnOTM3protectionGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { nnOme40Gotm3Protection 1 }
nnOTM3protectionGroupEntry OBJECT-TYPE
SYNTAX NnOTM3protectionGroupEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX { workingIfIndex, protectionIfIndex }
::= { nnOTM3protectionGroupTable 1 }
NnOTM3protectionGroupEntry ::=
SEQUENCE {
workingIfIndex
InterfaceIndex,
protectionIfIndex
InterfaceIndex,
ptRowStatus
RowStatus,
protectionSwitchDir
INTEGER,
protectionScheme
INTEGER,
waitToRestore
INTEGER,
revertive
INTEGER,
remoteStandardMode
INTEGER,
routeDiversity
INTEGER
}
workingIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION "working interface type"
::= { nnOTM3protectionGroupEntry 1 }
protectionIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-create
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionGroupEntry 2 }
ptRowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-write
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionGroupEntry 3 }
protectionSwitchDir OBJECT-TYPE
SYNTAX INTEGER {
bidirectional(1),
unidirectional(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionGroupEntry 4 }
protectionScheme OBJECT-TYPE
SYNTAX INTEGER {
one-plus-one(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionGroupEntry 5 }
waitToRestore OBJECT-TYPE
SYNTAX INTEGER {
one-minute(1),
two-minutes(2),
three-minutes(3),
four-minutes(4),
five-minutes(5),
six-minutes(6),
seven-minutes(7),
eight-minutes(8),
nine-minutes(9),
ten-minutes(10),
eleven-minutes(11),
twelve-minutes(12)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionGroupEntry 6 }
revertive OBJECT-TYPE
SYNTAX INTEGER {
yes(1),
no(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionGroupEntry 7 }
remoteStandardMode OBJECT-TYPE
SYNTAX INTEGER {
otn-g-873-1(1)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionGroupEntry 8 }
routeDiversity OBJECT-TYPE
SYNTAX INTEGER {
off(0)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionGroupEntry 9 }
nnOTM3protectionSwitchTable OBJECT-TYPE
SYNTAX SEQUENCE OF NnOTM3protectionSwitchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
::= { nnOme40Gotm3Protection 2 }
nnOTM3protectionSwitchEntry OBJECT-TYPE
SYNTAX NnOTM3protectionSwitchEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION ""
INDEX { ifIndex }
::= { nnOTM3protectionSwitchTable 1 }
NnOTM3protectionSwitchEntry ::=
SEQUENCE {
switchCommand
INTEGER,
switchStatus
INTEGER,
endInitiatingSwitch
INTEGER,
reasonForAutoSwitch
INTEGER
}
switchCommand OBJECT-TYPE
SYNTAX INTEGER {
man(1),
frcd(2),
lockout(3),
release(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionSwitchEntry 1 }
switchStatus OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
auto(2),
man(3),
frcd(4),
lockout(5)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionSwitchEntry 2 }
endInitiatingSwitch OBJECT-TYPE
SYNTAX INTEGER {
remote(1),
local(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionSwitchEntry 3 }
reasonForAutoSwitch OBJECT-TYPE
SYNTAX INTEGER {
sigok(1),
sf(2),
sd(3),
eber(4),
eqpfl(5),
facoos(6),
eqpoos(7),
osc(8),
wr(9)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION ""
::= { nnOTM3protectionSwitchEntry 4 }
END