TIMETRA-OES-HARDWARE-MIB DEFINITIONS ::= BEGIN
|
|
|
|
-- (c) Copyright 2013-2016 Nokia. All rights reserved.
|
|
-- This software is the confidential and proprietary property of
|
|
-- Nokia and may only be used in accordance with the
|
|
-- terms of the license agreement provided with this software.
|
|
|
|
IMPORTS
|
|
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
|
|
|
|
OBJECT-TYPE, MODULE-IDENTITY,
|
|
NOTIFICATION-TYPE, Unsigned32,
|
|
Integer32, Counter64, Gauge32,
|
|
Counter32 FROM SNMPv2-SMI
|
|
|
|
MODULE-COMPLIANCE, OBJECT-GROUP,
|
|
NOTIFICATION-GROUP FROM SNMPv2-CONF
|
|
|
|
TEXTUAL-CONVENTION, DateAndTime,
|
|
DisplayString, RowStatus,
|
|
TruthValue, TimeStamp FROM SNMPv2-TC
|
|
|
|
TmnxHwIndex, tmnxHwIndex,
|
|
TmnxPhysChassisIndex, TmnxLEDState,
|
|
TmnxCardRebootType, TmnxDeviceState,
|
|
tmnxHwClass FROM TIMETRA-CHASSIS-MIB
|
|
|
|
TmnxActionType, TmnxAdminState,
|
|
TmnxOperState, TNamedItemOrEmpty,
|
|
TItemDescription, TNamedItem FROM TIMETRA-TC-MIB
|
|
|
|
ifIndex FROM IF-MIB
|
|
|
|
tmnxSRObjs,tmnxSRConfs,
|
|
tmnxSRNotifyPrefix, timetraSRMIBModules FROM TIMETRA-GLOBAL-MIB
|
|
|
|
tmnxPortNotifyPortId,
|
|
TmnxPortOperStatus FROM TIMETRA-PORT-MIB
|
|
;
|
|
|
|
timetraOesHardwareMIBModule MODULE-IDENTITY
|
|
LAST-UPDATED "201308010000Z"
|
|
ORGANIZATION "Nokia"
|
|
CONTACT-INFO
|
|
"Nokia SROS Support
|
|
Web: http://www.nokia.com"
|
|
DESCRIPTION
|
|
"This document is the SNMP MIB module to manage and provision the
|
|
Optical Extension Shelf (OES) hardware components of the Nokia
|
|
SROS device.
|
|
|
|
Copyright (c) 2013-2016 Nokia. All rights reserved.
|
|
Reproduction of this document is authorized on the condition that
|
|
the foregoing copyright notice is included.
|
|
|
|
This SNMP MIB module (Specification) embodies Nokia's
|
|
proprietary intellectual property. Nokia retains
|
|
all title and ownership in the Specification, including any
|
|
revisions.
|
|
|
|
Nokia grants all interested parties a non-exclusive
|
|
license to use and distribute an unmodified copy of this
|
|
Specification in connection with management of Nokia
|
|
products, and without fee, provided this copyright notice and
|
|
license appear on all copies.
|
|
|
|
This Specification is supplied 'as is', and Nokia
|
|
makes no warranty, either express or implied, as to the use,
|
|
operation, condition, or performance of the Specification."
|
|
|
|
--
|
|
-- Revision History
|
|
--
|
|
REVISION "201308010000Z"
|
|
DESCRIPTION "Rev 1.0 05 Sep 2013 00:00
|
|
Initial release of the TIMETRA-OES-HARDWARE-MIB."
|
|
|
|
::= { timetraSRMIBModules 99 }
|
|
|
|
tmnxOesHwObjs OBJECT IDENTIFIER ::= { tmnxSRObjs 99 }
|
|
tmnxOesHwMIBNotifyPrefix OBJECT IDENTIFIER ::= { tmnxSRNotifyPrefix 99 }
|
|
tmnxOesHwConformance OBJECT IDENTIFIER ::= { tmnxSRConfs 99 }
|
|
|
|
-- Object Groups in the Nokia OES MIB Module
|
|
tmnxOesChassisObjs OBJECT IDENTIFIER ::= { tmnxOesHwObjs 1 }
|
|
tmnxOesCardObjs OBJECT IDENTIFIER ::= { tmnxOesHwObjs 2 }
|
|
tmnxOesPortObjs OBJECT IDENTIFIER ::= { tmnxOesHwObjs 3 }
|
|
tmnxOesHwNotifyObjs OBJECT IDENTIFIER ::= { tmnxOesHwObjs 4 }
|
|
|
|
-- Notification Groups in the Nokia OES MIB Module
|
|
tmnxOesHwNotifications OBJECT IDENTIFIER ::= { tmnxOesHwMIBNotifyPrefix 1 }
|
|
|
|
-- Compliance Groups in the Nokia OES MIB Module
|
|
tmnxOesHwCompliances OBJECT IDENTIFIER ::= { tmnxOesHwConformance 1 }
|
|
tmnxOesHwGroups OBJECT IDENTIFIER ::= { tmnxOesHwConformance 2 }
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- TIMETRA-OES-HARDWARE-MIB Textual Conventions
|
|
--
|
|
TmnxOesCardHFD ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesCardHFD specifies ..."
|
|
SYNTAX SnmpAdminString (SIZE(0..2))
|
|
|
|
TmnxOesHwMktPartNo ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesHwMktPartNo specifies ..."
|
|
SYNTAX SnmpAdminString (SIZE(0..20))
|
|
|
|
TmnxOesHwSWGenLoadName ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesHwSWGenLoadName specifies ..."
|
|
SYNTAX SnmpAdminString (SIZE(0..20))
|
|
|
|
TmnxOesHwLEDColorType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesHwLEDColorType specifies ..."
|
|
SYNTAX INTEGER {
|
|
unknown(1),
|
|
off(2),
|
|
red(3),
|
|
green(4),
|
|
orange(5)
|
|
}
|
|
|
|
TmnxOesHwLEDStateType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesHwLEDStateType specifies ..."
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
solid (2),
|
|
fastBlink (3),
|
|
slowBlink (4)
|
|
}
|
|
|
|
TmnxOesSlotNumber ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesSlotNumber specifies a unique index that identifies a physical
|
|
slot number within an OES chassis."
|
|
SYNTAX Unsigned32 (1..40)
|
|
|
|
TmnxOesChassisType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesChassisType specifies an Nokia SR OES chassis type."
|
|
SYNTAX Unsigned32
|
|
|
|
TmnxOesCardType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesCardType specifies an Nokia SR OES card type."
|
|
SYNTAX Unsigned32
|
|
|
|
TmnxOesCardSuppType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxCardSuppType specifies the valid card types supported for a
|
|
specific card slot. When multiple bits are set, it can be used to
|
|
identify a set or list of card types.
|
|
|
|
Some example card types:
|
|
|
|
112SCA1 -- 112G Single Port Tunable
|
|
112SNA1 -- 112G Single Port Tunable Coherent
|
|
130SCA1 -- 130G Single Port Tunable
|
|
EC -- Equipment Controller"
|
|
SYNTAX BITS {
|
|
invalid-card-type (0),
|
|
unassigned (1),
|
|
oes-supp-card-type-2 (2),
|
|
oes-supp-card-type-3 (3),
|
|
oes-supp-card-type-4 (4),
|
|
oes-supp-card-type-5 (5),
|
|
oes-supp-card-type-6 (6),
|
|
oes-supp-card-type-7 (7),
|
|
oes-supp-card-type-8 (8)
|
|
}
|
|
|
|
TmnxOesCmnEqpPortNumber ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxOesCmnEqpPortNumber specifies a unique index that identifies a
|
|
physical port number within an OES chassis common equipment slot."
|
|
SYNTAX Unsigned32
|
|
|
|
TmnxOesPortErrorStatus ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The TmnxOesPortErrorStatus is a bitmask which describes error
|
|
conditions that can be raised/cleared on an OES port.
|
|
|
|
The possible values are:
|
|
deviceFailure (0) - generic port device failure.
|
|
transmissionFailure (1) - port transmission failure."
|
|
SYNTAX BITS {
|
|
deviceFailure (0),
|
|
transmissionFailure (1)
|
|
}
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- TIMETRA-OES-HARDWARE-MIB Global Configuration Objects
|
|
--
|
|
tmnxOesChassisTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesChassisTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The chassis type table has an entry for each Nokia SROS EOS
|
|
series chassis model."
|
|
::= { tmnxOesChassisObjs 1 }
|
|
|
|
tmnxOesChassisTypeEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesChassisTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an Nokia SROS OES series chassis
|
|
model. Rows in this table are created by the agent at initialization
|
|
and cannot be created or destroyed by SNMP Get or Set requests."
|
|
INDEX { tmnxOesChassisTypeIndex }
|
|
::= { tmnxOesChassisTypeTable 1 }
|
|
|
|
TmnxOesChassisTypeEntry ::= SEQUENCE {
|
|
tmnxOesChassisTypeIndex TmnxOesChassisType,
|
|
tmnxOesChassisTypeName TNamedItemOrEmpty,
|
|
tmnxOesChassisTypeDescription TItemDescription,
|
|
tmnxOesChassisTypeStatus TruthValue
|
|
}
|
|
|
|
tmnxOesChassisTypeIndex OBJECT-TYPE
|
|
SYNTAX TmnxOesChassisType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisTypeIndex specifies the type of
|
|
Nokia SROS series OES chassis model."
|
|
::= { tmnxOesChassisTypeEntry 1 }
|
|
|
|
tmnxOesChassisTypeName OBJECT-TYPE
|
|
SYNTAX TNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisTypeName indicates the administrative name
|
|
that identifies this type of Nokia SROS series OES chassis
|
|
model. This name string may be used in CLI commands to specify a
|
|
particular OES chassis model type."
|
|
::= { tmnxOesChassisTypeEntry 2 }
|
|
|
|
tmnxOesChassisTypeDescription OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisTypeDescription indicates the detailed
|
|
description of this Nokia SROS series OES chassis model."
|
|
::= { tmnxOesChassisTypeEntry 3 }
|
|
|
|
tmnxOesChassisTypeStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisTypeStatus indicates the chassis type
|
|
support. When tmnxOesChassisTypeStatus has a value of 'true' it
|
|
indicates that this chassis model is supported in this revision of the
|
|
management software. When it has a value of 'false' there is no
|
|
support."
|
|
::= { tmnxOesChassisTypeEntry 4 }
|
|
|
|
tmnxOesChassisLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisLastChange indicates the time, since
|
|
system startup, when tmnxOesChassisTable last changed configuration."
|
|
::= { tmnxOesChassisObjs 2 }
|
|
|
|
tmnxOesChassisTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesChassisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxOesChassisTable contains configuration information for
|
|
OES chassis."
|
|
::= { tmnxOesChassisObjs 3 }
|
|
|
|
tmnxOesChassisEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesChassisEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxOesChassisEntry consists of the configurable objects for
|
|
a given OES chassis."
|
|
INDEX { tmnxOesChassisNumber }
|
|
::= { tmnxOesChassisTable 1 }
|
|
|
|
TmnxOesChassisEntry ::= SEQUENCE {
|
|
tmnxOesChassisNumber TmnxPhysChassisIndex,
|
|
tmnxOesChassisRowStatus RowStatus,
|
|
tmnxOesChassisRowLastChanged TimeStamp,
|
|
tmnxOesChassisAssignedType TmnxOesChassisType,
|
|
tmnxOesChassisEquippedType TmnxOesChassisType,
|
|
tmnxOesChassisActivitySwitch TmnxActionType,
|
|
tmnxOesChassisHwEntryIndex TmnxHwIndex
|
|
}
|
|
|
|
tmnxOesChassisNumber OBJECT-TYPE
|
|
SYNTAX TmnxPhysChassisIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisNumber specifies a unique value which
|
|
identifies the OES chassis."
|
|
::= { tmnxOesChassisEntry 1 }
|
|
|
|
tmnxOesChassisRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisRowStatus specifies the row status.
|
|
It allows the creation and deletion of rows in tmnxOesChassisTable.
|
|
|
|
When creating an OES Chassis entry, tmnxOesChassisRowStatus and
|
|
tmnxOesChassisAssignedType must be set together in the same SNMP SET
|
|
request PDU."
|
|
::= { tmnxOesChassisEntry 2 }
|
|
|
|
tmnxOesChassisRowLastChanged OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisRowLastChanged indicates the time this row
|
|
was last changed."
|
|
::= { tmnxOesChassisEntry 3 }
|
|
|
|
tmnxOesChassisAssignedType OBJECT-TYPE
|
|
SYNTAX TmnxOesChassisType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisAssignedType specifies the administratively
|
|
assigned type of the OES chassis.
|
|
|
|
tmnxOesChassisRowStatus and tmnxOesChassisAssignedType must be set
|
|
together in the same SNMP SET request PDU."
|
|
DEFVAL { 1 }
|
|
::= { tmnxOesChassisEntry 4 }
|
|
|
|
tmnxOesChassisEquippedType OBJECT-TYPE
|
|
SYNTAX TmnxOesChassisType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisEquippedType indicates the OES chassis type
|
|
that is equipped."
|
|
::= { tmnxOesChassisEntry 5 }
|
|
|
|
tmnxOesChassisActivitySwitch OBJECT-TYPE
|
|
SYNTAX TmnxActionType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesChassisActivitySwitch specifies the activity switch
|
|
action for the OES chassis. When the value is set to 'doAction (1)',
|
|
the OES chassis causes an activity switchover between this chassis's
|
|
controller (i.e. EC) cards."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxOesChassisEntry 6 }
|
|
|
|
tmnxOesChassisHwEntryIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value is a unique index that identifies
|
|
common management information for Nokia SROS series
|
|
manufactured hardware components within the specified chassis."
|
|
::= { tmnxOesChassisEntry 7 }
|
|
|
|
tmnxOesPFTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesPFEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table tmnxOesPFTable contains information about the OES
|
|
power filter cards."
|
|
::= { tmnxOesChassisObjs 4 }
|
|
|
|
tmnxOesPFEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesPFEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in tmnxOesPFTable is created/destroyed by the SYSTEM when there
|
|
is a row created/destroyed in the tmnxHwTable for an OES power
|
|
filter card."
|
|
INDEX { tmnxOesChassisNumber,
|
|
tmnxOesSlotNumber }
|
|
::= { tmnxOesPFTable 1 }
|
|
|
|
TmnxOesPFEntry ::= SEQUENCE {
|
|
tmnxOesSlotNumber TmnxOesSlotNumber,
|
|
tmnxOesPFType INTEGER,
|
|
tmnxOesPFAmpRating Unsigned32,
|
|
tmnxOesPFInputCurrent Unsigned32,
|
|
tmnxOesPFInputVoltage Unsigned32,
|
|
tmnxOesPFInputPower Unsigned32,
|
|
tmnxOesPFClkA Unsigned32,
|
|
tmnxOesPFClkB Unsigned32,
|
|
tmnxOesPFClkDelta Integer32,
|
|
tmnxOesPFState TmnxDeviceState,
|
|
tmnxOesPFHwIndex TmnxHwIndex
|
|
}
|
|
|
|
tmnxOesSlotNumber OBJECT-TYPE
|
|
SYNTAX TmnxOesSlotNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesSlotNumber specifies the slot number of an OES
|
|
power filter card."
|
|
::= { tmnxOesPFEntry 1 }
|
|
|
|
tmnxOesPFType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ac (1),
|
|
dc (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFType indicates the type of an OES power filter
|
|
card."
|
|
::= { tmnxOesPFEntry 2 }
|
|
|
|
tmnxOesPFAmpRating OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "deci-amps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFAmpRating indicates the amperage rating of an OES
|
|
power filter."
|
|
::= { tmnxOesPFEntry 3 }
|
|
|
|
tmnxOesPFInputCurrent OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milli-amps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFInputCurrent indicates the input current of an
|
|
OES power filter."
|
|
::= { tmnxOesPFEntry 4 }
|
|
|
|
tmnxOesPFInputVoltage OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "milli-volts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFInputVoltage indicates the input voltage of an
|
|
OES power filter."
|
|
::= { tmnxOesPFEntry 5 }
|
|
|
|
tmnxOesPFInputPower OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "watts"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFInputPower indicates the input power of an OES
|
|
power filter."
|
|
::= { tmnxOesPFEntry 6 }
|
|
|
|
tmnxOesPFClkA OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "1/10 parts-per-million"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFClkA indicates the frequency offset
|
|
of clock A of the OES power filter."
|
|
::= { tmnxOesPFEntry 7 }
|
|
|
|
tmnxOesPFClkB OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "1/10 parts-per-million"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFClkB indicates the frequency offset
|
|
of clock B of the OES power filter."
|
|
::= { tmnxOesPFEntry 8 }
|
|
|
|
tmnxOesPFClkDelta OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "1/10 parts-per-million"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFClkDelta indicates the difference between
|
|
the frequency offset of clock A and that of clock B"
|
|
::= { tmnxOesPFEntry 9 }
|
|
|
|
tmnxOesPFState OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFState indicates an OES power filter's operational
|
|
|
|
state."
|
|
::= { tmnxOesPFEntry 10 }
|
|
|
|
tmnxOesPFHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPFHwIndex indicates a unique index of common
|
|
management information for hardware components within the specified
|
|
chassis."
|
|
::= { tmnxOesPFEntry 11 }
|
|
|
|
tmnxOesFanLastChg OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of sysUpTime when tmnxOesFanTable was last changed."
|
|
::= { tmnxOesChassisObjs 5 }
|
|
|
|
tmnxOesFanTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table tmnxOesFanTable contains the information pertaining
|
|
to the fan tray(s) of OES chassis."
|
|
::= { tmnxOesChassisObjs 6 }
|
|
|
|
tmnxOesFanEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesFanEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rows in tmnxOesFanTable are created/destroyed by the SYSTEM when
|
|
tmnxOesChassisEntry rows are created/destroyed. Only certain slots
|
|
can contain a fan in each OES chassis type."
|
|
INDEX { tmnxOesChassisNumber,
|
|
tmnxOesFanSlotNumber }
|
|
::= { tmnxOesFanTable 1 }
|
|
|
|
TmnxOesFanEntry ::= SEQUENCE {
|
|
tmnxOesFanSlotNumber TmnxOesSlotNumber,
|
|
tmnxOesFanState TmnxDeviceState,
|
|
tmnxOesFanSpeedControl INTEGER,
|
|
tmnxOesFanHwIndex TmnxHwIndex
|
|
}
|
|
|
|
tmnxOesFanSlotNumber OBJECT-TYPE
|
|
SYNTAX TmnxOesSlotNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesFanSlotNumber specifies the slot number of the
|
|
fan in OES chassis."
|
|
::= { tmnxOesFanEntry 1 }
|
|
|
|
tmnxOesFanState OBJECT-TYPE
|
|
SYNTAX TmnxDeviceState
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesFanState indicates the fan's operational state."
|
|
::= { tmnxOesFanEntry 2 }
|
|
|
|
tmnxOesFanSpeedControl OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
normal (1),
|
|
maximum (2)
|
|
}
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesFanSpeedControl specifies the level of the fan
|
|
speed."
|
|
DEFVAL { normal }
|
|
::= { tmnxOesFanEntry 3 }
|
|
|
|
tmnxOesFanHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesFanHwIndex indicates a unique index that
|
|
identifies common management information for Nokia SROS
|
|
series manufactured hardware components within the specified chassis."
|
|
::= { tmnxOesFanEntry 4 }
|
|
|
|
tmnxOesCardTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesCardTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The card type table has an entry for each Nokia SROS EOS
|
|
series card model."
|
|
::= { tmnxOesCardObjs 1 }
|
|
|
|
tmnxOesCardTypeEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesCardTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an Nokia SROS series Card model.
|
|
Rows in this table are created by the agent at initialization and
|
|
cannot be created or destroyed by SNMP Get or Set requests."
|
|
INDEX { tmnxOesCardTypeIndex }
|
|
::= { tmnxOesCardTypeTable 1 }
|
|
|
|
TmnxOesCardTypeEntry ::= SEQUENCE {
|
|
tmnxOesCardTypeIndex TmnxOesCardType,
|
|
tmnxOesCardTypeName SnmpAdminString,
|
|
tmnxOesCardTypeDescription SnmpAdminString,
|
|
tmnxOesCardTypeStatus TruthValue,
|
|
tmnxOesCardTypeHeight Unsigned32,
|
|
tmnxOesCardTypeWidth Unsigned32,
|
|
tmnxOesCardTypeNumPorts Unsigned32
|
|
}
|
|
|
|
tmnxOesCardTypeIndex OBJECT-TYPE
|
|
SYNTAX TmnxOesCardType
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The unique index value which identifies this type of Nokia
|
|
SROS series OES card model."
|
|
::= { tmnxOesCardTypeEntry 1 }
|
|
|
|
tmnxOesCardTypeName OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..31))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The administrative name that identifies this type of Nokia
|
|
SROS series OES card model. This name string may be used in
|
|
CLI commands to specify a particular card model type."
|
|
::= { tmnxOesCardTypeEntry 2 }
|
|
|
|
tmnxOesCardTypeDescription OBJECT-TYPE
|
|
SYNTAX SnmpAdminString (SIZE(0..255))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A detailed description of this Nokia SROS series OES card
|
|
model."
|
|
::= { tmnxOesCardTypeEntry 3 }
|
|
|
|
tmnxOesCardTypeStatus OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"When tmnxOesCardTypeStatus has a value of 'true' it indicates that
|
|
this card model is supported in this revision of the management
|
|
software. When it has a value of 'false' there is no support."
|
|
::= { tmnxOesCardTypeEntry 4 }
|
|
|
|
tmnxOesCardTypeHeight OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value indicates the number of vertical slots this card type
|
|
occupies."
|
|
::= { tmnxOesCardTypeEntry 5 }
|
|
|
|
tmnxOesCardTypeWidth OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value indicates the number of horizontal slots this card type
|
|
occupies."
|
|
::= { tmnxOesCardTypeEntry 6 }
|
|
|
|
tmnxOesCardTypeNumPorts OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value indicates the number of ports that this card type contains."
|
|
::= { tmnxOesCardTypeEntry 7 }
|
|
|
|
tmnxOesCardLastChange OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCardLastChange indicates the time since system
|
|
startup this table was last changed."
|
|
::= { tmnxOesCardObjs 2 }
|
|
|
|
tmnxOesCardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxOesCardTable has an entry for each OES card slot in
|
|
each chassis."
|
|
::= { tmnxOesCardObjs 3 }
|
|
|
|
tmnxOesCardEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Each row entry represents an OES card slot in an OES chassis in
|
|
the system. Entries cannot be created and deleted via
|
|
SNMP SET operations. When tmnxOesChassisEntry is created,
|
|
a tmnxOesCardEntry is created for each OES card slot in that
|
|
chassis."
|
|
INDEX { tmnxOesChassisNumber,
|
|
tmnxOesSlotNumber }
|
|
::= { tmnxOesCardTable 1 }
|
|
|
|
TmnxOesCardEntry ::= SEQUENCE {
|
|
tmnxOesCardAssignedType TmnxOesCardType,
|
|
tmnxOesCardEquippedType TmnxOesCardType,
|
|
tmnxOesCardSupportedTypes TmnxOesCardSuppType,
|
|
tmnxOesCardReboot TmnxCardRebootType,
|
|
tmnxOesCardHwEntryIndex TmnxHwIndex,
|
|
tmnxOesCardRowLastChanged TimeStamp,
|
|
tmnxOesCardMemorySize Unsigned32
|
|
}
|
|
|
|
tmnxOesCardAssignedType OBJECT-TYPE
|
|
SYNTAX TmnxOesCardType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCardAssignedType specifies the administratively
|
|
assigned OES card type that should occupy this fabric slot in this
|
|
chassis."
|
|
DEFVAL { 2 }
|
|
::= { tmnxOesCardEntry 1 }
|
|
|
|
tmnxOesCardEquippedType OBJECT-TYPE
|
|
SYNTAX TmnxOesCardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCardEquippedType indicates the OES card type that
|
|
is physically inserted into this slot in this chassis."
|
|
::= { tmnxOesCardEntry 2 }
|
|
|
|
tmnxOesCardSupportedTypes OBJECT-TYPE
|
|
SYNTAX TmnxOesCardSuppType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCardSupportedTypes indicates what OES card types
|
|
can be configured in this slot in this chassis."
|
|
::= { tmnxOesCardEntry 3 }
|
|
|
|
tmnxOesCardReboot OBJECT-TYPE
|
|
SYNTAX TmnxCardRebootType
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCardReboot specifies the reboot type and
|
|
executes the reboot. Setting this variable to 'cardReboot' causes
|
|
the OES card to execute a soft-reboot. Setting this variable to
|
|
'cardPowerCycle' causes the OES card to turn off and turn on power
|
|
to the card initiating a hard-reboot."
|
|
DEFVAL { notApplicable }
|
|
::= { tmnxOesCardEntry 4 }
|
|
|
|
tmnxOesCardHwEntryIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCardHwEntryIndex indicates a unique index that
|
|
identifies common management information for Nokia SROS
|
|
series manufactured hardware components within the specified chassis."
|
|
::= { tmnxOesCardEntry 5 }
|
|
|
|
tmnxOesCardRowLastChanged OBJECT-TYPE
|
|
SYNTAX TimeStamp
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCardRowLastChanged indicates the time since system
|
|
startup this row was last changed."
|
|
::= { tmnxOesCardEntry 6 }
|
|
|
|
tmnxOesCardMemorySize OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "Giga-bytes"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCardMemorySize indicates the amount of memory
|
|
populated on this OES card."
|
|
::= { tmnxOesCardEntry 7 }
|
|
|
|
tmnxOesControlCardTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesControlCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table tmnxOesControlCardTable contains information pertaining to
|
|
the OES equipment controller (EC)."
|
|
::= { tmnxOesCardObjs 4 }
|
|
|
|
tmnxOesControlCardEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesControlCardEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in tmnxOesControlCardTable is created/destroyed by the SYSTEM
|
|
when there is a row created/destroyed in tmnxOesChassisTable for each
|
|
OES chassis."
|
|
INDEX { tmnxOesChassisNumber,
|
|
tmnxOesSlotNumber }
|
|
::= { tmnxOesControlCardTable 1 }
|
|
|
|
TmnxOesControlCardEntry ::= SEQUENCE {
|
|
tmnxOesControlCardActState INTEGER,
|
|
tmnxOesControlCardHwIndex TmnxHwIndex
|
|
}
|
|
|
|
tmnxOesControlCardActState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
unknown (1),
|
|
active (2),
|
|
standby (3),
|
|
unequipped (4)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesControlCardActState indicates whether or not
|
|
this control card is active."
|
|
::= { tmnxOesControlCardEntry 1 }
|
|
|
|
tmnxOesControlCardHwIndex OBJECT-TYPE
|
|
SYNTAX TmnxHwIndex
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesControlCardHwIndex indicates a unique index that
|
|
identifies common management information for Nokia SROS
|
|
series manufactured hardware components within the specified chassis."
|
|
::= { tmnxOesControlCardEntry 2 }
|
|
|
|
-- Common equipment port table
|
|
|
|
tmnxOesCmnEqpPortTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesCmnEqpPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table tmnxOesCmnEqpPortTable contains the information pertaining
|
|
to the ports of the common equipment cards of the OES chassis. The
|
|
common equipment represents the hardware which includes the shelf,
|
|
shelf controller, user panel (USPNL), equipment controller (EC), first
|
|
level controller (FLC), PSS power distribution units, power filter
|
|
card (PFD), fans, etc."
|
|
::= { tmnxOesPortObjs 1 }
|
|
|
|
tmnxOesCmnEqpPortEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesCmnEqpPortEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Row in tmnxOesCmnEqpPortTable is created/destroyed by the SYSTEM
|
|
when there is a row created/destroyed in the tmnxHwTable for each OES
|
|
common equipment, e.g. equipment controller (EC) and user panel."
|
|
INDEX { tmnxOesChassisNumber,
|
|
tmnxOesSlotNumber,
|
|
tmnxOesCmnEqpPortNumber}
|
|
::= { tmnxOesCmnEqpPortTable 1}
|
|
|
|
TmnxOesCmnEqpPortEntry ::= SEQUENCE {
|
|
tmnxOesCmnEqpPortNumber TmnxOesCmnEqpPortNumber,
|
|
tmnxOesCmnEqpPortCardType TmnxOesCardType,
|
|
tmnxOesCmnEqpPortOperStatus TmnxPortOperStatus
|
|
}
|
|
|
|
tmnxOesCmnEqpPortNumber OBJECT-TYPE
|
|
SYNTAX TmnxOesCmnEqpPortNumber
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCmnEqpPortNumber specifies the index of the
|
|
tmnxOesCmnEqpPortTable table. It is a number that represents
|
|
a port of the common equipment card uniquely within the card. This
|
|
index along with the other indexes of the table are used to map this
|
|
port uniquely within the equipment cards in an OES chassis."
|
|
::= { tmnxOesCmnEqpPortEntry 1 }
|
|
|
|
tmnxOesCmnEqpPortCardType OBJECT-TYPE
|
|
SYNTAX TmnxOesCardType
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCmnEqpPortCardType indicates the type of the
|
|
common equipment card that the port belongs to."
|
|
::= { tmnxOesCmnEqpPortEntry 2 }
|
|
|
|
tmnxOesCmnEqpPortOperStatus OBJECT-TYPE
|
|
SYNTAX TmnxPortOperStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCmnEqpPortOperStatus indicates the operational
|
|
status of the port of the OES common equipment card."
|
|
::= { tmnxOesCmnEqpPortEntry 3 }
|
|
|
|
-- Common equipment port type table
|
|
|
|
tmnxOesCmnEqpPortTypeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxOesCmnEqpPortTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The table tmnxOesCmnEqpPortTypeTable contains the information
|
|
pertaining to the type of the ports of the common equipment cards,
|
|
e.g. equipment control (EC) and user panel, of the OES chassis."
|
|
::= { tmnxOesPortObjs 2 }
|
|
|
|
tmnxOesCmnEqpPortTypeEntry OBJECT-TYPE
|
|
SYNTAX TmnxOesCmnEqpPortTypeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Rows in table tmnxOesCmnEqpPortTypeEntry are created by the SYSTEM at
|
|
initialization and can not be created or destroyed by SNMP
|
|
set requests. Each row represents an OES port within a common
|
|
equipment OES card of a certain type."
|
|
INDEX {tmnxOesCardTypeIndex, tmnxOesCmnEqpPortNumber }
|
|
::= { tmnxOesCmnEqpPortTypeTable 1 }
|
|
|
|
TmnxOesCmnEqpPortTypeEntry ::= SEQUENCE {
|
|
tmnxOesCmnEqpPortTypeName TNamedItem,
|
|
tmnxOesCmnEqpPortTypeDescr TItemDescription
|
|
}
|
|
|
|
tmnxOesCmnEqpPortTypeName OBJECT-TYPE
|
|
SYNTAX TNamedItem
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCmnEqpPortTypeName indicates the administrative
|
|
name that describes the OES common equipment port type."
|
|
::= { tmnxOesCmnEqpPortTypeEntry 1 }
|
|
|
|
tmnxOesCmnEqpPortTypeDescr OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesCmnEqpPortTypeDescr indicates the detailed
|
|
description of the OES common equipment port type."
|
|
::= { tmnxOesCmnEqpPortTypeEntry 2 }
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- TIMETRA-OES-HARDWARE-MIB Notification Objects
|
|
--
|
|
tmnxOesNotifyFailureReason OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesNotifyFailureReason is used by OES card or common
|
|
equipment failure notifications to indicate the reason of failure."
|
|
::= { tmnxOesHwNotifyObjs 1 }
|
|
|
|
tmnxOesPortNotifyError OBJECT-TYPE
|
|
SYNTAX TmnxOesPortErrorStatus
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxOesPortNotifyError indicates the error conditions
|
|
on this OES port."
|
|
::= { tmnxOesHwNotifyObjs 2 }
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- TIMETRA-OES-HARDWARE-MIB Notifications
|
|
--
|
|
tmnxOesCtlCardPortDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxOesCmnEqpPortOperStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesCtlCardPortDown notification is generated when a
|
|
port (e.g. ES 1 or AUX) on an OES Control Card (e.g. EC card) is not
|
|
operational. The reason may be a misconnected, disconnected or faulty
|
|
cable, a faulty port or Control Card.
|
|
|
|
[EFFECT] If an ES (Extension Shelf) port is down then one of the
|
|
control plane communication paths between EC (Equipment Controller)
|
|
cards in different OES Chassis is not available. The control
|
|
communications with one or more OES subtending chassis may be
|
|
affected rendering the Chassis unmanageable. Other control paths
|
|
may be available.
|
|
|
|
If an AUX port is down then one of the control plane communication
|
|
paths between the router and the OES Master Chassis is not available
|
|
and control communications with the OES may be affected rendering
|
|
the OES unmanageable. Other control paths may be available.
|
|
|
|
[RECOVERY] Check that the cable is correctly connected and test the
|
|
cable."
|
|
::= { tmnxOesHwNotifications 1 }
|
|
|
|
tmnxOesCtlCardPortUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxOesCmnEqpPortOperStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesCtlCardPortUp notification is generated when the
|
|
port on the OES Control Card (e.g. EC card) is operational.
|
|
|
|
[EFFECT] If an ES port is up then a control plane communication path
|
|
between EC cards in different OES Chassis has been established.
|
|
|
|
If an AUX port is up then a control plane communication path between
|
|
the router and the OES Master Chassis has been established and the OES
|
|
can be managed by the router.
|
|
|
|
[RECOVERY] No recovery required"
|
|
::= { tmnxOesHwNotifications 2 }
|
|
|
|
|
|
tmnxOesUsrpnlPortDown NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxOesCmnEqpPortOperStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesUsrpnlPortDown notification is generated when
|
|
a port (E1 or E2) on an OES USRPNL card is not operational. The
|
|
reason may be a misconnected, disconnected or faulty cable, or a
|
|
faulty port or USRPNL.
|
|
|
|
[EFFECT] If an E1 or E2 port is down then one of the control plane
|
|
communication paths between the router and the OES Master Chassis is
|
|
not available. The control communications with the OES may be affected
|
|
rendering the OES chassis unmanageable. Other control communications
|
|
paths may be available.
|
|
|
|
[RECOVERY] Check that the cable is correctly connected and test the
|
|
cable."
|
|
::= { tmnxOesHwNotifications 3 }
|
|
|
|
tmnxOesUsrpnlPortUp NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxOesCmnEqpPortOperStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesUsrpnlPortUp notification is generated when the
|
|
OES USRPNL port is now operational.
|
|
|
|
[EFFECT] If an E1 or E2 port is up then a control plane communication
|
|
path between the router and the OES Master Chassis has been established
|
|
and the OES can be managed by the router.
|
|
|
|
[RECOVERY] No recovery required."
|
|
::= { tmnxOesHwNotifications 4 }
|
|
|
|
tmnxOesFanRemoved NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanRemoved notification is generated when the OES
|
|
fan unit is removed from its slot in the OES chassis.
|
|
|
|
[EFFECT] The function of OES fan unit is not available.
|
|
|
|
[RECOVERY] Insert OES fan unit into its slot."
|
|
::= { tmnxOesHwNotifications 5 }
|
|
|
|
tmnxOesFanInserted NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanInserted notification is generated when the OES
|
|
fan unit is inserted into its slot in the OES chassis.
|
|
|
|
[EFFECT] The OES chassis is now equipped with a fan unit.
|
|
|
|
[RECOVERY] No recovery required."
|
|
::= { tmnxOesHwNotifications 6 }
|
|
|
|
tmnxOesFan32HReqd NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFan32HReqd notification is generated when the
|
|
OES chassis in a PSS32 shelf requires high speed fan (FAN32H), but the
|
|
fan inserted is not the right type.
|
|
|
|
[EFFECT] The OES chassis is not operating with required fan type.
|
|
|
|
[RECOVERY] Replace the OES fan unit with the correct one for 1830
|
|
PSS32 shelf."
|
|
::= { tmnxOesHwNotifications 7 }
|
|
|
|
tmnxOesFan32HReqdClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFan32HReqdClear notification is generated when the
|
|
OES chassis is equipped with FAN32H or when the alarmed fan unit with
|
|
tmnxOesFan32HReqd condition is removed from the slot.
|
|
|
|
[EFFECT] The OES chassis is operating with required fan type for 1830
|
|
PSS32 shelf (FAN32H), or the incorrect fan unit has been removed.
|
|
|
|
[RECOVERY] No recovery required."
|
|
::= { tmnxOesHwNotifications 8 }
|
|
|
|
tmnxOesFanFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass,
|
|
tmnxOesFanState,
|
|
tmnxOesNotifyFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanFailure notification is generated when the fan
|
|
unit in an OES chassis has failed. tmnxOesNotifyFailureReason contains
|
|
the reason for fan failure.
|
|
|
|
[EFFECT] The fan unit in the OES chassis is out of service.
|
|
|
|
[RECOVERY] If the condition causing fan failure can not be removed,
|
|
replace the faulty fan unit."
|
|
::= { tmnxOesHwNotifications 9 }
|
|
|
|
tmnxOesFanFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass,
|
|
tmnxOesFanState,
|
|
tmnxOesNotifyFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanFailureClear notification is generated when fan
|
|
failure in an OES chassis is cleared. tmnxOesNotifyFailureReason contains
|
|
the reason for fan failure being cleared.
|
|
|
|
[EFFECT] The fan unit in the OES chassis is in service.
|
|
|
|
[RECOVERY] No recovery required."
|
|
::= { tmnxOesHwNotifications 10 }
|
|
|
|
tmnxOesPowerSupplyRemoved NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesPowerSupplyRemoved notification is generated when
|
|
an OES power supply unit is removed from its slot in the OES chassis.
|
|
|
|
[EFFECT] The power supply unit is not present in the indicated OES
|
|
chassis slot.
|
|
|
|
[RECOVERY] Insert OES power supply unit into its slot."
|
|
::= { tmnxOesHwNotifications 11 }
|
|
|
|
tmnxOesPowerSupplyInserted NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesPowerSupplyInserted notification is generated when
|
|
the OES power supply unit is inserted into its slot in the OES chassis.
|
|
|
|
[EFFECT] The indicated slot of the OES chassis is now equipped with
|
|
the power supply unit.
|
|
|
|
[RECOVERY] No recovery required."
|
|
::= { tmnxOesHwNotifications 12 }
|
|
|
|
tmnxOesPowerSupplyFailure NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass,
|
|
tmnxOesPFState,
|
|
tmnxOesNotifyFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesPowerSupplyFailure notification is generated when
|
|
the power supply unit in the indicated slot of the OES chassis has
|
|
failed. tmnxOesNotifyFailureReason contains the reason for the failure.
|
|
|
|
[EFFECT] The indicated OES power supply unit is out of service.
|
|
|
|
[RECOVERY] If the condition causing the power supply failure can not
|
|
be removed, replace the faulty power supply unit."
|
|
::= { tmnxOesHwNotifications 13 }
|
|
|
|
tmnxOesPowerSupplyFailureClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass,
|
|
tmnxOesPFState,
|
|
tmnxOesNotifyFailureReason
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesPowerSupplyFailureClear notification is generated
|
|
when the power supply failure in the indicated slot of the OES chassis
|
|
is cleared. tmnxOesNotifyFailureReason contains the reason for the
|
|
power supply failure being cleared.
|
|
|
|
[EFFECT] The indicated power supply unit in the OES chassis is
|
|
in service.
|
|
|
|
[RECOVERY] No recovery required."
|
|
::= { tmnxOesHwNotifications 14 }
|
|
|
|
tmnxOesPortError NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxPortNotifyPortId,
|
|
tmnxOesPortNotifyError
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesPortError notification is generated when an error
|
|
condition listed in tmnxOesPortNotifyError is detected on the OES port.
|
|
|
|
[EFFECT] The OES port is experiencing errors that could be service affecting.
|
|
|
|
[RECOVERY] tmnxOesPortError is cleared by taking the port out of
|
|
service, eg. shutdown, or try a soft reset, hard reset, then replacement
|
|
of the card if the error condition persists."
|
|
::= { tmnxOesHwNotifications 15 }
|
|
|
|
tmnxOesPortErrorClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxPortNotifyPortId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesPortErrorClear notification is generated when
|
|
all error conditions on the OES port are cleared.
|
|
|
|
[EFFECT] The OES port error conditions are cleared.
|
|
|
|
[RECOVERY] No recovery required."
|
|
::= { tmnxOesHwNotifications 16 }
|
|
|
|
tmnxOesCtlCardActivityChange NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesCtlCardActivityChange notification is generated
|
|
when the active Equipment Controller has changed to the card
|
|
specified by the tmnxHwIndex.
|
|
|
|
[EFFECT] The active Equipment Controller has moved to the previously
|
|
standby card.
|
|
|
|
[RECOVERY] No recovery is required."
|
|
::= { tmnxOesHwNotifications 17 }
|
|
|
|
tmnxOesFpgaFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFpgaFail notification is generated during an
|
|
out-of-service upgrade when the FPGA file downloaded to the card was
|
|
corrupt or the FPGA failed to program correctly.
|
|
|
|
[EFFECT] The OES card shall automatically cold reboot and the card
|
|
shall attempt to recover. While the condition exists the card remains
|
|
out-of-service.
|
|
|
|
[RECOVERY] If the card has rebooted and the condition did not clear,
|
|
then first reseat the card and see if the condition clears. If the
|
|
condition remains, then replace the card and follow the return and
|
|
repair process for the problem card."
|
|
::= { tmnxOesHwNotifications 18 }
|
|
|
|
tmnxOesFpgaFailClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFpgaFailClear notification is generated when the
|
|
FPGA is successfully programmed.
|
|
|
|
[EFFECT] The FPGA is successfully programmed.
|
|
|
|
[RECOVERY] No recovery is required."
|
|
::= { tmnxOesHwNotifications 19 }
|
|
|
|
tmnxOesFpgaTimeout NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFpgaTimeout notification is generated when the FPGA
|
|
file download and reprogramming took longer than expected (about 45
|
|
minutes).
|
|
|
|
[EFFECT] The FPGA on the indicated card was not reprogrammed in the
|
|
time window.
|
|
|
|
[RECOVERY] If the OES card is operational, wait for a maintenance window
|
|
and reset the OES card."
|
|
::= { tmnxOesHwNotifications 20 }
|
|
|
|
tmnxOesFpgaTimeoutClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFpgaTimeoutClear notification is generated
|
|
when the OES FPGA timeout condition is cleared.
|
|
|
|
[EFFECT] The FPGA is successfully programmed.
|
|
|
|
[RECOVERY] No recovery is required."
|
|
::= { tmnxOesHwNotifications 21 }
|
|
|
|
|
|
tmnxOesOptTrnspndrMiscFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesOptTrnspndrMiscFail notification is generated when
|
|
a non-service affecting hardware defect is detected on the card.
|
|
This condition may be declared on the card due to one of the
|
|
following causes:
|
|
1) Detection of line side transmitter laser bias or optical output
|
|
power nearing end-of-life.
|
|
2) Detection of line receiver ITLA (Integrated Tunable Laser
|
|
Assembly) laser bias or output power nearing end-of-life.
|
|
3) Detection of board-level Analog-to-Digital Conversion Digital
|
|
Signal Processor (ADC DSP) device defect.
|
|
4) A device-to-device interface communication problem.
|
|
|
|
[EFFECT] The tmnxOesOptTrnspndrMiscFail alarm indicates a lower
|
|
priority fault on the card that does not directly affect the
|
|
traffic currently flowing through the card. However, the card
|
|
should be replaced at the next available maintenance opportunity.
|
|
|
|
[RECOVERY] Replace the card."
|
|
::= { tmnxOesHwNotifications 22 }
|
|
|
|
tmnxOesCardDegraded NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesCardDegraded notification is generated when a fault
|
|
on the card has caused the system to declare a hardware failure.
|
|
This condition may be declared due to a failure in the SEEP or
|
|
another hardware failure, depending on the card type the alarm is
|
|
raised against.
|
|
|
|
[EFFECT] The tmnxOesCardDegraded alarm indicates a lower priority
|
|
fault on the card that does not directly affect the traffic
|
|
currently flowing through the device.
|
|
|
|
[RECOVERY] First attempt a soft reset of the card. If the card has
|
|
rebooted and the condition does not clear, then try a hard reset of
|
|
the card. If the card has rebooted and the condition does not clear,
|
|
then remove the card and re-insert it to see if the condition clears.
|
|
If the condition remains, then replace the card and follow the return
|
|
and repair process for the problem card."
|
|
::= { tmnxOesHwNotifications 23 }
|
|
|
|
tmnxOesFanSpeedHigh NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanSpeedHigh notification is generated when the fan
|
|
speed is too high, based upon the current shelf cooling requirements.
|
|
|
|
[EFFECT] The fans run faster than required.
|
|
|
|
[RECOVERY] Remove and re-insert the fan tray into the chassis. If the
|
|
alarm does not clear then replace the fan tray."
|
|
::= { tmnxOesHwNotifications 24 }
|
|
|
|
tmnxOesFanSpeedHighClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanSpeedHighClear notification is generated when
|
|
the conditions causing a tmnxOesFanSpeedHigh notification have been
|
|
cleared. Fan speed has returned to acceptable conditions.
|
|
|
|
[EFFECT] The fan speed is normal.
|
|
|
|
[RECOVERY] No recovery is required."
|
|
::= { tmnxOesHwNotifications 25 }
|
|
|
|
tmnxOesFanSpeedLow NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanSpeedLow notification is generated when the fan
|
|
speed is too low, based upon the current shelf cooling requirements.
|
|
|
|
[EFFECT] The fans run slower than required.
|
|
|
|
[RECOVERY] Check for airflow blockage or a dirty filter, and clear.
|
|
If no problems are found, replace the fan tray."
|
|
::= { tmnxOesHwNotifications 26 }
|
|
|
|
tmnxOesFanSpeedLowClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanSpeedLowClear notification is generated when the
|
|
conditions causing a tmnxOesFanSpeedLow notification have been cleared.
|
|
Fan speed has returned to acceptable conditions.
|
|
|
|
[EFFECT] The fan speed is normal.
|
|
|
|
[RECOVERY] No recovery is required."
|
|
|
|
::= { tmnxOesHwNotifications 27 }
|
|
|
|
tmnxOesTempLow NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesTempLow notification is generated when the card
|
|
has detected its temperature is below operational limits.
|
|
|
|
[EFFECT] The card performance may degrade or may not work as expected.
|
|
|
|
[RECOVERY] Ensure that no environmental issues exist where the network
|
|
element resides. Resolve any existing issues."
|
|
::= { tmnxOesHwNotifications 28 }
|
|
|
|
tmnxOesTempLowClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesFanSpeedLowClear notification is generated when the
|
|
card has indicated its temperature is within operational limits.
|
|
|
|
[EFFECT] The card resumes normal operation state.
|
|
|
|
[RECOVERY] No recovery is required."
|
|
|
|
::= { tmnxOesHwNotifications 29 }
|
|
|
|
tmnxOesRedundancyFail NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesRedundancyFail notification is generated when the
|
|
inactive equipment controller card in the OES is not providing
|
|
redundancy protection. In some cases this is a transitory alarm that
|
|
occurs as redundant Equipment Controllers discover one another and
|
|
synchronize. Typical causes for the persistence of this alarm are:
|
|
1) Irreconcilable database schemas.
|
|
2) Inability to support system timing.
|
|
3) System timing is compromised. The inactive controller system
|
|
timing module is not reporting the same status as the active
|
|
controller or is reporting an error that the active controller
|
|
does not have.
|
|
4) Subshelf link missing.
|
|
Reasons that are generally transitory are:
|
|
1) Database not yet fully synchronized.
|
|
2) Software loads are not yet synchronized.
|
|
Some or all of these may apply when the alarm is raised.
|
|
|
|
[EFFECT] The OES is not protected against failure of the active
|
|
Equipment Controller.
|
|
|
|
[RECOVERY] Check for the Redundancy demerit in the detailed information
|
|
of the chassis indicated."
|
|
|
|
::= { tmnxOesHwNotifications 30 }
|
|
|
|
tmnxOesRedundancyReady NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesRedundancyReady notification is generated when the
|
|
equipment controller cards in the indicated OES chassis are providing
|
|
redundant protection. The equipment controller cards are synchronized.
|
|
|
|
[EFFECT] The equipment controller cards are synchronized.
|
|
|
|
[RECOVERY] No recovery is required."
|
|
|
|
::= { tmnxOesHwNotifications 31 }
|
|
|
|
tmnxOesCardFirmwareErr NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxHwClass
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxOesCardFirmwareErr is raised when
|
|
the device installed in the shelf has an EEPROM that does not contain
|
|
the correct or recognizable information.
|
|
|
|
[EFFECT] The card may demonstrate other alarms due to this condition.
|
|
|
|
[RECOVERY] Replace the card."
|
|
|
|
::= { tmnxOesHwNotifications 33 }
|
|
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- TIMETRA-OES-HARDWARE-MIB Compliance Statements
|
|
--
|
|
tmnxOesHwV14v0Compliance MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for management of OES
|
|
on Nokia SROS series systems for release 14.0."
|
|
MODULE -- this module
|
|
MANDATORY-GROUPS {
|
|
tmnxOesHwGroupV14v0,
|
|
tmnxOesHwNotifyObjsGroupV14v0,
|
|
tmnxOesHwNotificationGroupV14v0
|
|
}
|
|
::= { tmnxOesHwCompliances 1 }
|
|
|
|
--%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
|
|
--
|
|
-- TIMETRA-OES-HARDWARE-MIB Group Statements
|
|
--
|
|
tmnxOesHwV14v0Groups OBJECT IDENTIFIER ::= { tmnxOesHwGroups 1 }
|
|
|
|
tmnxOesHwGroupV14v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxOesChassisRowLastChanged,
|
|
tmnxOesChassisRowStatus,
|
|
tmnxOesChassisTypeName,
|
|
tmnxOesChassisTypeDescription,
|
|
tmnxOesChassisTypeStatus,
|
|
tmnxOesChassisLastChange,
|
|
tmnxOesChassisAssignedType,
|
|
tmnxOesChassisEquippedType,
|
|
tmnxOesChassisActivitySwitch,
|
|
tmnxOesChassisHwEntryIndex,
|
|
tmnxOesPFType,
|
|
tmnxOesPFAmpRating,
|
|
tmnxOesPFInputCurrent,
|
|
tmnxOesPFInputVoltage,
|
|
tmnxOesPFInputPower,
|
|
tmnxOesPFClkA,
|
|
tmnxOesPFClkB,
|
|
tmnxOesPFClkDelta,
|
|
tmnxOesPFState,
|
|
tmnxOesPFHwIndex,
|
|
tmnxOesFanLastChg,
|
|
tmnxOesFanState,
|
|
tmnxOesFanSpeedControl,
|
|
tmnxOesFanHwIndex,
|
|
tmnxOesCardTypeName,
|
|
tmnxOesCardTypeDescription,
|
|
tmnxOesCardTypeStatus,
|
|
tmnxOesCardTypeHeight,
|
|
tmnxOesCardTypeWidth,
|
|
tmnxOesCardTypeNumPorts,
|
|
tmnxOesCardLastChange,
|
|
tmnxOesCardAssignedType,
|
|
tmnxOesCardEquippedType,
|
|
tmnxOesCardSupportedTypes,
|
|
tmnxOesCardReboot,
|
|
tmnxOesCardHwEntryIndex,
|
|
tmnxOesCardRowLastChanged,
|
|
tmnxOesCardMemorySize,
|
|
tmnxOesControlCardActState,
|
|
tmnxOesControlCardHwIndex,
|
|
tmnxOesCmnEqpPortCardType,
|
|
tmnxOesCmnEqpPortOperStatus,
|
|
tmnxOesCmnEqpPortTypeDescr,
|
|
tmnxOesCmnEqpPortTypeName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting management of OES on Nokia
|
|
SROS series systems in release 14.0."
|
|
::= { tmnxOesHwV14v0Groups 1 }
|
|
|
|
tmnxOesHwNotifyObjsGroupV14v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxOesNotifyFailureReason,
|
|
tmnxOesPortNotifyError
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting OES notifications on Nokia
|
|
SROS series systems in release 14.0."
|
|
::= { tmnxOesHwV14v0Groups 2 }
|
|
|
|
tmnxOesHwNotificationGroupV14v0 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxOesCtlCardPortDown,
|
|
tmnxOesCtlCardPortUp,
|
|
tmnxOesUsrpnlPortDown,
|
|
tmnxOesUsrpnlPortUp,
|
|
tmnxOesFanRemoved,
|
|
tmnxOesFanInserted,
|
|
tmnxOesFan32HReqd,
|
|
tmnxOesFan32HReqdClear,
|
|
tmnxOesFanFailure,
|
|
tmnxOesFanFailureClear,
|
|
tmnxOesPowerSupplyRemoved,
|
|
tmnxOesPowerSupplyInserted,
|
|
tmnxOesPowerSupplyFailure,
|
|
tmnxOesPowerSupplyFailureClear,
|
|
tmnxOesPortError,
|
|
tmnxOesPortErrorClear,
|
|
tmnxOesCtlCardActivityChange,
|
|
tmnxOesFpgaFail,
|
|
tmnxOesFpgaFailClear,
|
|
tmnxOesFpgaTimeout,
|
|
tmnxOesFpgaTimeoutClear,
|
|
tmnxOesOptTrnspndrMiscFail,
|
|
tmnxOesCardDegraded,
|
|
tmnxOesFanSpeedHigh,
|
|
tmnxOesFanSpeedHighClear,
|
|
tmnxOesFanSpeedLow,
|
|
tmnxOesFanSpeedLowClear,
|
|
tmnxOesRedundancyFail,
|
|
tmnxOesRedundancyReady,
|
|
tmnxOesCardFirmwareErr,
|
|
tmnxOesTempLow,
|
|
tmnxOesTempLowClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of notifications supporting the OES hardware
|
|
capabilities on Nokia SROS series systems in release 14.0."
|
|
::= { tmnxOesHwV14v0Groups 3 }
|
|
|
|