6046 lines
231 KiB
Plaintext
6046 lines
231 KiB
Plaintext
TIMETRA-IEEE8021-CFM-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
Dot1agCfmInterfaceStatus,
|
|
Dot1agCfmLowestAlarmPri,
|
|
Dot1agCfmMDLevel,
|
|
Dot1agCfmMaintAssocName,
|
|
Dot1agCfmMaintDomainNameType,
|
|
Dot1agCfmMepId, Dot1agCfmMepIdOrZero,
|
|
Dot1agCfmMpDirection,
|
|
Dot1agCfmPortStatus, VlanId,
|
|
VlanIdOrNone, dot1agCfmDefaultMdEntry,
|
|
dot1agCfmMaCompEntry, dot1agCfmMaIndex,
|
|
dot1agCfmMaMepListEntry,
|
|
dot1agCfmMaNetEntry, dot1agCfmMdEntry,
|
|
dot1agCfmMdIndex, dot1agCfmMepDbEntry,
|
|
dot1agCfmMepEntry,
|
|
dot1agCfmMepIdentifier,
|
|
dot1agCfmMepTransmitLbmDestMacAddress,
|
|
dot1agCfmMepTransmitLtmSeqNumber
|
|
FROM IEEE8021-CFM-MIB
|
|
InterfaceIndex, InterfaceIndexOrZero
|
|
FROM IF-MIB
|
|
LldpChassisIdSubtype
|
|
FROM LLDP-MIB
|
|
MODULE-COMPLIANCE, NOTIFICATION-GROUP,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
Counter32, Gauge32, Integer32,
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE,
|
|
OBJECT-TYPE, Unsigned32
|
|
FROM SNMPv2-SMI
|
|
DateAndTime, DisplayString, MacAddress,
|
|
RowStatus, TEXTUAL-CONVENTION,
|
|
TimeInterval, TruthValue
|
|
FROM SNMPv2-TC
|
|
timetraSRMIBModules, tmnxSRConfs,
|
|
tmnxSRNotifyPrefix, tmnxSRObjs
|
|
FROM TIMETRA-GLOBAL-MIB
|
|
SdpId
|
|
FROM TIMETRA-SERV-MIB
|
|
TFCSet, TItemDescription, TLNamedItem,
|
|
TLNamedItemOrEmpty, TNamedItem,
|
|
TmnxCreateOrigin, TmnxEnabledDisabled,
|
|
TmnxServId
|
|
FROM TIMETRA-TC-MIB
|
|
;
|
|
|
|
timetraIEEE8021CfmMIBModule MODULE-IDENTITY
|
|
LAST-UPDATED "201603110000Z"
|
|
ORGANIZATION "Nokia"
|
|
CONTACT-INFO
|
|
"Nokia SROS Support
|
|
Web: http://www.nokia.com"
|
|
DESCRIPTION
|
|
"This document is the SNMP MIB module to manage and provision dot1ag
|
|
Connectivity Fault Management module functionality for the Nokia SROS
|
|
products. This includes extensions to the IEEE8021-CFM MIB.
|
|
|
|
Copyright 2008-2018 Nokia. All rights reserved. Reproduction of this
|
|
document is authorized on the condition that the foregoing copyright
|
|
notice is included.
|
|
|
|
This SNMP MIB module (Specification) embodies Nokia's
|
|
proprietary intellectual property. Nokia retains
|
|
all title and ownership in the Specification, including any
|
|
revisions.
|
|
|
|
Nokia grants all interested parties a non-exclusive license to use and
|
|
distribute an unmodified copy of this Specification in connection with
|
|
management of Nokia products, and without fee, provided this copyright
|
|
notice and license appear on all copies.
|
|
|
|
This Specification is supplied 'as is', and Nokia makes no warranty,
|
|
either express or implied, as to the use, operation, condition, or
|
|
performance of the Specification."
|
|
|
|
REVISION "201603110000Z"
|
|
DESCRIPTION
|
|
"Rev 15.0 11 Mar 2016 00:00
|
|
15.0 release of the TIMETRA-IEEE8021-CFM-MIB."
|
|
|
|
REVISION "201601010000Z"
|
|
DESCRIPTION
|
|
"Rev 14.0 1 Jan 2016 00:00
|
|
14.0 release of the TIMETRA-IEEE8021-CFM-MIB."
|
|
|
|
REVISION "201501010000Z"
|
|
DESCRIPTION
|
|
"Rev 13.0 1 Jan 2015 00:00
|
|
13.0 release of the TIMETRA-IEEE8021-CFM-MIB."
|
|
|
|
REVISION "201401010000Z"
|
|
DESCRIPTION
|
|
"Rev 12.0 1 Jan 2014 00:00
|
|
12.0 release of the TIMETRA-IEEE8021-CFM-MIB."
|
|
|
|
REVISION "201102010000Z"
|
|
DESCRIPTION
|
|
"Rev 9.0 1 Feb 2011 00:00
|
|
9.0 release of the TIMETRA-IEEE8021-CFM-MIB."
|
|
|
|
REVISION "200902280000Z"
|
|
DESCRIPTION
|
|
"Rev 7.0 28 Feb 2009 00:00
|
|
7.0 release of the TIMETRA-IEEE8021-CFM-MIB."
|
|
|
|
REVISION "200801010000Z"
|
|
DESCRIPTION
|
|
"Rev 1.0 01 Jan 2008 00:00
|
|
Initial version of the TIMETRA-IEEE8021-CFM-MIB."
|
|
|
|
::= { timetraSRMIBModules 52 }
|
|
|
|
Dot1agCfmStatisticOpcodeName ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An enumerated value indicating the CFM PDU Opcode to which a statistic
|
|
may be associated.
|
|
|
|
other(1) Indicates the CFM PDU type does not match
|
|
any other type explicitly detailed below.
|
|
|
|
ccm(2) Connectivity check messages.
|
|
|
|
lbr(3) Loopback response messages.
|
|
|
|
lbm(4) Loopback request messages.
|
|
|
|
ltr(5) Linktrace response messages.
|
|
|
|
ltm(6) Linktrace request messages.
|
|
|
|
ais(7) Alarm indication signal messages.
|
|
|
|
lck(8) Ethernet locked signal messages.
|
|
|
|
tst(9) Ethernet test signal messages.
|
|
|
|
laps(10) Linear automatic protection switching messages.
|
|
|
|
raps(11) Ring automatic protection switching messages.
|
|
|
|
mcc(12) Maintenance communications channel messages.
|
|
|
|
lmr(13) Ethernet loss measurement response messages.
|
|
|
|
lmm(14) Ethernet loss measurement messages.
|
|
|
|
odm(15) One way delay measurement messages.
|
|
|
|
dmr(16) Delay measurement response messages.
|
|
|
|
dmm(17) Delay measurement message.
|
|
|
|
exr(18) Ethernet experimental response messages.
|
|
|
|
exm(19) Ethernet experimental messages.
|
|
|
|
csf(20) Client signal fail messages.
|
|
|
|
vsr(21) Vendor specific response messages.
|
|
|
|
vsm(22) Vendor specific messages.
|
|
|
|
osl(23) One way synthetic loss measurement messages.
|
|
|
|
slr(24) Synthetic loss measurement response messages.
|
|
|
|
slm(25) Synthetic loss measurement messages.
|
|
|
|
gnm(26) Generic notification messages."
|
|
REFERENCE
|
|
"Y.1731 clauses 7 and 8"
|
|
SYNTAX INTEGER {
|
|
other (1),
|
|
ccm (2),
|
|
lbr (3),
|
|
lbm (4),
|
|
ltr (5),
|
|
ltm (6),
|
|
ais (7),
|
|
lck (8),
|
|
tst (9),
|
|
laps (10),
|
|
raps (11),
|
|
mcc (12),
|
|
lmr (13),
|
|
lmm (14),
|
|
odm (15),
|
|
dmr (16),
|
|
dmm (17),
|
|
exr (18),
|
|
exm (19),
|
|
csf (20),
|
|
vsr (21),
|
|
vsm (22),
|
|
osl (23),
|
|
slr (24),
|
|
slm (25),
|
|
gnm (26)
|
|
}
|
|
|
|
TmnxDot1agCfmMepFclty ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"TmnxDot1agCfmMepFclty is an enumerated integer that indicates the
|
|
facility type that a facility MEP has affected.
|
|
|
|
value indicates
|
|
-----------------------------------
|
|
port(1) physical port
|
|
lag (2) lag port
|
|
networkInterface(3) network interface
|
|
qinqPortTunnelSap(4) QinQ on physical port
|
|
qinqLagTunnelSap(5) QinQ on lag port"
|
|
SYNTAX INTEGER {
|
|
port (1),
|
|
lag (2),
|
|
networkInterface (3),
|
|
qinqPortTunnelSap (4),
|
|
qinqLagTunnelSap (5)
|
|
}
|
|
|
|
TmnxDot1agCfmMaintDomainNameOrEmpty ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The data type TmnxDot1agCfmMaintDomainNameOrEmpty specifies a generic
|
|
Maintenance Domain Name as described by IEEE8021-CFM-MIB
|
|
Dot1agCfmMaintDomainName.
|
|
|
|
In addition, a zero-length name is also accepted when IEEE8021-CFM-MIB
|
|
Dot1agCfmMaintDomainNameType value is set to 'none (1)'."
|
|
SYNTAX OCTET STRING (SIZE (0..43))
|
|
|
|
TmnxDot1agCfmMaintAssocNameType ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A value that represents a type (and thereby the format) of a
|
|
Dot1agCfmMaintAssocName. The values refer directly to the
|
|
Dot1agCfmMaintAssocNameType with the additional ituReserved(xx)
|
|
defined for iccBased(32). This is a refinement of the
|
|
Dot1agCfmMaintAssocNameType and follows the same rules and details as
|
|
it does.
|
|
|
|
ieeeReserved(0) Reserved for definition by IEEE 802.1
|
|
recommend to not use zero unless
|
|
absolutely needed.
|
|
primaryVid(1) Primary VLAN ID.
|
|
12 bits represented in a 2-octet integer:
|
|
- 4 least significant bits of the first
|
|
byte contains the 4 most significant
|
|
bits of the 12 bits primary VID
|
|
- second byte contains the 8 least
|
|
significant bits of the primary VID
|
|
|
|
0 1 2 3 4 5 6 7 8
|
|
+-+-+-+-+-+-+-+-+
|
|
|0 0 0 0| (MSB) |
|
|
+-+-+-+-+-+-+-+-+
|
|
| VID LSB |
|
|
+-+-+-+-+-+-+-+-+
|
|
|
|
charString(2) RFC2579 DisplayString, except that the
|
|
character codes 0-31 (decimal) are not
|
|
used. (1..45) octets
|
|
unsignedInt16(3) 2-octet integer/big endian
|
|
rfc2865VpnId(4) RFC 2685 VPN ID
|
|
3 octet VPN authority Organizationally
|
|
Unique Identifier followed by 4 octet VPN
|
|
index identifying VPN according to the OUI:
|
|
|
|
0 1 2 3 4 5 6 7 8
|
|
+-+-+-+-+-+-+-+-+
|
|
| VPN OUI (MSB) |
|
|
+-+-+-+-+-+-+-+-+
|
|
| VPN OUI |
|
|
+-+-+-+-+-+-+-+-+
|
|
| VPN OUI (LSB) |
|
|
+-+-+-+-+-+-+-+-+
|
|
|VPN Index (MSB)|
|
|
+-+-+-+-+-+-+-+-+
|
|
| VPN Index |
|
|
+-+-+-+-+-+-+-+-+
|
|
| VPN Index |
|
|
+-+-+-+-+-+-+-+-+
|
|
|VPN Index (LSB)|
|
|
+-+-+-+-+-+-+-+-+
|
|
iccBased(32) The ICC value for Y.1731.
|
|
It is taken from the ituReserved(xx) range of
|
|
the Dot1agCfmMaintAssocNameType."
|
|
SYNTAX INTEGER {
|
|
primaryVid (1),
|
|
charString (2),
|
|
unsignedInt16 (3),
|
|
rfc2865VpnId (4),
|
|
iccBased (32)
|
|
}
|
|
|
|
TmnxDot1agCfmMhfCreation ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates if the Management Entity can create MHFs. This is a
|
|
refinement of Dot1agCfmMhfCreation.
|
|
|
|
The valid values are:
|
|
|
|
defMHFnone(1) No MHFs can be created for this VID.
|
|
defMHFdefault(2) MHFs can be created on this VID on any
|
|
Bridge port through which this VID can
|
|
pass.
|
|
defMHFexplicit(3) MHFs can be created for this VID only on
|
|
Bridge ports through which this VID can
|
|
pass, and only if a MEP is created at some
|
|
lower MD Level.
|
|
defMHFstatic (32) multiple MHFs can be created on the
|
|
primary VID on any bridge port through
|
|
which this primary VID can pass,
|
|
provided that any existing MEP is
|
|
created at a lower MD level."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.5.1.3:c and 22.2.3"
|
|
SYNTAX INTEGER {
|
|
defMHFnone (1),
|
|
defMHFdefault (2),
|
|
defMHFexplicit (3),
|
|
defMHFstatic (32)
|
|
}
|
|
|
|
TmnxDot1agCfmIdPermission ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates what, if anything, is to be included in the Sender ID TLV
|
|
transmitted in CCMs, LBMs, LTMs, and LTRs.
|
|
|
|
This is a refinement of Dot1agCfmIdPermission.
|
|
|
|
The valid values are:
|
|
|
|
sendIdNone(1) The Sender ID TLV is not to be sent.
|
|
sendIdChassis(2) The Chassis ID Length, Chassis ID
|
|
Subtype, and Chassis ID fields of the
|
|
Sender ID TLV are to be sent."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.6.1.3:d and 21.5.3"
|
|
SYNTAX INTEGER {
|
|
sendIdNone (1),
|
|
sendIdChassis (2)
|
|
}
|
|
|
|
TmnxDot1agCfmCcmInterval ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Indicates the interval at which CCMs are sent by a MEP. The possible
|
|
values are:
|
|
|
|
interval300Hz(1) CCMs are sent every 3 1/3 milliseconds.
|
|
interval10ms(2) CCMs are sent every 10 milliseconds.
|
|
interval100ms(3) CCMs are sent every 100 milliseconds.
|
|
interval1s(4) CCMs are sent every 1 second.
|
|
interval10s(5) CCMs are sent every 10 seconds.
|
|
interval1min(6) CCMs are sent every minute.
|
|
interval10min(7) CCMs are sent every 10 minutes."
|
|
REFERENCE
|
|
"802.1ag clauses 12.14.6.1.3:e, 20.8.1 and 21.6.1.3"
|
|
SYNTAX INTEGER {
|
|
interval300Hz (1),
|
|
interval10ms (2),
|
|
interval100ms (3),
|
|
interval1s (4),
|
|
interval10s (5),
|
|
interval1min (6),
|
|
interval10min (7)
|
|
}
|
|
|
|
TmnxDot1agCfmMdIndexOrNone ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An object of type TmnxDot1agCfmMdIndexOrNone specifies a configurable
|
|
index value in the Maintenance Domain table, or indicates that no
|
|
index is specified.
|
|
|
|
Md-index zero (0) specifies that no index is set."
|
|
SYNTAX Unsigned32 (0 | 1..4294967295)
|
|
|
|
TmnxDot1agCfmMaIndexOrNone ::= TEXTUAL-CONVENTION
|
|
STATUS current
|
|
DESCRIPTION
|
|
"An object of type TmnxDot1agCfmMaIndexOrNone specifies a configurable
|
|
index value in the Maintenance Domain table, or indicates that no
|
|
index is specified.
|
|
|
|
Md-index zero (0) specifies that no index is set."
|
|
SYNTAX Unsigned32 (0 | 1..4294967295)
|
|
|
|
tmnxDot1agMIBObjs OBJECT IDENTIFIER ::= { tmnxSRObjs 52 }
|
|
|
|
tmnxDot1agCfmStack OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 1 }
|
|
|
|
tmnxDot1agCfmSdpBindStackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmSdpBindStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There is one CFM SDP-Bind Stack table per bridge. It permits the
|
|
retrieval of information about the Maintenance Points configured on
|
|
any given SDP bindings."
|
|
REFERENCE
|
|
"802.1ag clauses 12.14.2"
|
|
::= { tmnxDot1agCfmStack 1 }
|
|
|
|
tmnxDot1agCfmSdpBindStackEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmSdpBindStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the tmnxDot1agCfmSdpBindStackTable. This row
|
|
behaves exactly like the dot1agCfmStackEntry row."
|
|
INDEX {
|
|
tmnxDot1agCfmSdpBindStackSdpId,
|
|
tmnxDot1agCfmSdpBindStackVcId,
|
|
tmnxDot1agCfmSdpBindStackMdLevel,
|
|
tmnxDot1agCfmSdpBindStackDirection
|
|
}
|
|
::= { tmnxDot1agCfmSdpBindStackTable 1 }
|
|
|
|
TmnxDot1agCfmSdpBindStackEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmSdpBindStackSdpId SdpId,
|
|
tmnxDot1agCfmSdpBindStackVcId Unsigned32,
|
|
tmnxDot1agCfmSdpBindStackMdLevel Dot1agCfmMDLevel,
|
|
tmnxDot1agCfmSdpBindStackDirection Dot1agCfmMpDirection,
|
|
tmnxDot1agCfmSdpBindStackMdIndex Unsigned32,
|
|
tmnxDot1agCfmSdpBindStackMaIndex Unsigned32,
|
|
tmnxDot1agCfmSdpBindStackMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmSdpBindStackMacAddress MacAddress
|
|
}
|
|
|
|
tmnxDot1agCfmSdpBindStackSdpId OBJECT-TYPE
|
|
SYNTAX SdpId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpBindStackSdpId specifies the Bridge Port
|
|
or aggregated port on which MEPs or MHFs might be configured."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:a"
|
|
::= { tmnxDot1agCfmSdpBindStackEntry 1 }
|
|
|
|
tmnxDot1agCfmSdpBindStackVcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpBindStackVcId specifies, along with
|
|
tmnxDot1agCfmSdpBindStackSdpId, the SDP Binding for the bridge."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:d"
|
|
::= { tmnxDot1agCfmSdpBindStackEntry 2 }
|
|
|
|
tmnxDot1agCfmSdpBindStackMdLevel OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMDLevel
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpBindStackMdLevel specifies the MD Level
|
|
of the Maintenance Point."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:b"
|
|
::= { tmnxDot1agCfmSdpBindStackEntry 3 }
|
|
|
|
tmnxDot1agCfmSdpBindStackDirection OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMpDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpBindStackDirection specifies the
|
|
Direction in which the MP faces on the Bridge Port"
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:c"
|
|
::= { tmnxDot1agCfmSdpBindStackEntry 4 }
|
|
|
|
tmnxDot1agCfmSdpBindStackMdIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpBindStackMdIndex indicates the index of
|
|
the Maintenance Domain in the dot1agCfmMdTable to which the MP is
|
|
associated, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:b"
|
|
::= { tmnxDot1agCfmSdpBindStackEntry 5 }
|
|
|
|
tmnxDot1agCfmSdpBindStackMaIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpBindStackMaIndex indicates the index of
|
|
the MA in the dot1agCfmMaNetTable and dot1agCfmMaCompTable to which
|
|
the MP is associated, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:c"
|
|
::= { tmnxDot1agCfmSdpBindStackEntry 6 }
|
|
|
|
tmnxDot1agCfmSdpBindStackMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpBindStackMepId indicates if an MEP is
|
|
configured, the MEPID, else 0"
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:d"
|
|
::= { tmnxDot1agCfmSdpBindStackEntry 7 }
|
|
|
|
tmnxDot1agCfmSdpBindStackMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpBindStackMacAddress indicates the MAC
|
|
address of the MP."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:e"
|
|
::= { tmnxDot1agCfmSdpBindStackEntry 8 }
|
|
|
|
tmnxDot1agCfmStackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There is one CFM Stack table per bridge. It permits the retrieval of
|
|
information about the Maintenance Points configured on any given
|
|
interface."
|
|
REFERENCE
|
|
"802.1ag clauses 12.14.2"
|
|
::= { tmnxDot1agCfmStack 2 }
|
|
|
|
tmnxDot1agCfmStackEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Stack table entry"
|
|
INDEX {
|
|
tmnxDot1agCfmStackifIndex,
|
|
tmnxDot1agCfmStackVlanIdOrNone,
|
|
tmnxDot1agCfmStackMdLevel,
|
|
tmnxDot1agCfmStackDirection
|
|
}
|
|
::= { tmnxDot1agCfmStackTable 1 }
|
|
|
|
TmnxDot1agCfmStackEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmStackifIndex InterfaceIndex,
|
|
tmnxDot1agCfmStackVlanIdOrNone Unsigned32,
|
|
tmnxDot1agCfmStackMdLevel Dot1agCfmMDLevel,
|
|
tmnxDot1agCfmStackDirection Dot1agCfmMpDirection,
|
|
tmnxDot1agCfmStackMdIndex Unsigned32,
|
|
tmnxDot1agCfmStackMaIndex Unsigned32,
|
|
tmnxDot1agCfmStackMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmStackMacAddress MacAddress,
|
|
tmnxDot1agCfmStackMPType INTEGER
|
|
}
|
|
|
|
tmnxDot1agCfmStackifIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the Bridge Port or aggregated port
|
|
on which MEPs or MHFs might be configured.
|
|
|
|
Upon a restart of the system, the system SHALL, if necessary,
|
|
change the value of this variable, and rearrange the
|
|
dot1agCfmStackTable, so that it indexes the entry in the
|
|
interface table with the same value of ifAlias that it
|
|
indexed before the system restart. If no such entry exists,
|
|
then the system SHALL delete all entries in the
|
|
dot1agCfmStackTable with the interface index."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:a"
|
|
::= { tmnxDot1agCfmStackEntry 1 }
|
|
|
|
tmnxDot1agCfmStackVlanIdOrNone OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID to which the MP is attached, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clauses 12.14.2.1.2:d, 22.1.7"
|
|
::= { tmnxDot1agCfmStackEntry 2 }
|
|
|
|
tmnxDot1agCfmStackMdLevel OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMDLevel
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MD Level of the Maintenance Point."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:b"
|
|
::= { tmnxDot1agCfmStackEntry 3 }
|
|
|
|
tmnxDot1agCfmStackDirection OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMpDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Direction in which the MP faces on the Bridge Port"
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:c"
|
|
::= { tmnxDot1agCfmStackEntry 4 }
|
|
|
|
tmnxDot1agCfmStackMdIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the Maintenance Domain in the dot1agCfmMdTable to which
|
|
the MP is associated, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:b"
|
|
::= { tmnxDot1agCfmStackEntry 5 }
|
|
|
|
tmnxDot1agCfmStackMaIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the MA in the dot1agCfmMaNetTable and
|
|
dot1agCfmMaCompTable to which the MP is associated, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:c"
|
|
::= { tmnxDot1agCfmStackEntry 6 }
|
|
|
|
tmnxDot1agCfmStackMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If an MEP is configured, the MEPID, else 0"
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:d"
|
|
::= { tmnxDot1agCfmStackEntry 7 }
|
|
|
|
tmnxDot1agCfmStackMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC address of the MP."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:e"
|
|
::= { tmnxDot1agCfmStackEntry 8 }
|
|
|
|
tmnxDot1agCfmStackMPType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
sap (1),
|
|
ethTun (2),
|
|
ethRing (3),
|
|
facPort (4),
|
|
facInterface (5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmStackMPType indicates the entity that the
|
|
MP is configured on:
|
|
sap(1) MP is configured on a SAP
|
|
ethTun(2) MP is configured on an ethernet-tunnel
|
|
ethRing(3) MP is configured on an ethernet-ring
|
|
facPort(4) MP is configured on a facility port
|
|
facInterface(5) MP is configured on a facility interface"
|
|
::= { tmnxDot1agCfmStackEntry 9 }
|
|
|
|
tmnxDot1agCfmVStackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmVStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There is one CFM Virtual Stack entry per service. It permits the
|
|
retrieval of information about the Maintenance Points configured on
|
|
any given virtual Maintenance Association End Point (MEP)."
|
|
REFERENCE
|
|
"802.1ag clauses 12.14.2"
|
|
::= { tmnxDot1agCfmStack 3 }
|
|
|
|
tmnxDot1agCfmVStackEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmVStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the tmnxDot1agCfmVStackTable.
|
|
|
|
There exists one row for each configured virtual MEP in the system.
|
|
Rows are created and destroyed based on the existence of a virtual
|
|
MEP."
|
|
INDEX {
|
|
tmnxDot1agCfmVStackSvcId,
|
|
tmnxDot1agCfmVStackMdLevel,
|
|
tmnxDot1agCfmVStackDirection
|
|
}
|
|
::= { tmnxDot1agCfmVStackTable 1 }
|
|
|
|
TmnxDot1agCfmVStackEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmVStackSvcId TmnxServId,
|
|
tmnxDot1agCfmVStackMdLevel Dot1agCfmMDLevel,
|
|
tmnxDot1agCfmVStackDirection Dot1agCfmMpDirection,
|
|
tmnxDot1agCfmVStackMdIndex Unsigned32,
|
|
tmnxDot1agCfmVStackMaIndex Unsigned32,
|
|
tmnxDot1agCfmVStackMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmVStackMacAddress MacAddress
|
|
}
|
|
|
|
tmnxDot1agCfmVStackSvcId OBJECT-TYPE
|
|
SYNTAX TmnxServId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmVStackSvcId specifies the service on which
|
|
MEPs might be configured."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:a"
|
|
::= { tmnxDot1agCfmVStackEntry 1 }
|
|
|
|
tmnxDot1agCfmVStackMdLevel OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMDLevel
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmVStackMdLevel specifies the Maintenance
|
|
Domain (MD) Level of the Maintenance Point."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:b"
|
|
::= { tmnxDot1agCfmVStackEntry 2 }
|
|
|
|
tmnxDot1agCfmVStackDirection OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMpDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmVStackDirection specifies the direction in
|
|
which the Maintenance Point (MP) faces on the service."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:c"
|
|
::= { tmnxDot1agCfmVStackEntry 3 }
|
|
|
|
tmnxDot1agCfmVStackMdIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmVStackMdIndex indicates the index of the
|
|
Maintenance Domain in the dot1agCfmMdTable to which the Maintenance
|
|
Point (MP) is associated, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:b"
|
|
::= { tmnxDot1agCfmVStackEntry 4 }
|
|
|
|
tmnxDot1agCfmVStackMaIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmVStackMaIndex indicates the index of the
|
|
Maintenance Association (MA) in the dot1agCfmMaNetTable and
|
|
dot1agCfmMaCompTable to which the Maintenance Point (MP) is
|
|
associated, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:c"
|
|
::= { tmnxDot1agCfmVStackEntry 5 }
|
|
|
|
tmnxDot1agCfmVStackMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmVStackMepId indicates if an MEP is
|
|
configured, the MEPID, else 0."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:d"
|
|
::= { tmnxDot1agCfmVStackEntry 6 }
|
|
|
|
tmnxDot1agCfmVStackMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmVStackMacAddress indicates the MAC address
|
|
of the MP."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:e"
|
|
::= { tmnxDot1agCfmVStackEntry 7 }
|
|
|
|
tmnxDot1agCfmPVStackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmPVStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"There is one CFM Stack table per bridge. It permits the retrieval of
|
|
information about the Maintenance Points (MP) configured on any given
|
|
interface."
|
|
REFERENCE
|
|
"802.1ag clauses 12.14.2"
|
|
::= { tmnxDot1agCfmStack 4 }
|
|
|
|
tmnxDot1agCfmPVStackEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmPVStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Primary VLAN-ID Stack table entry. Entries in this table are MEPs
|
|
configured to use the primary VLAN-ID of the Maintenance Association
|
|
(MA)."
|
|
INDEX {
|
|
tmnxDot1agCfmPVStackifIndex,
|
|
tmnxDot1agCfmPVStackVlanIdOrNone,
|
|
tmnxDot1agCfmPVStackPriVlanId,
|
|
tmnxDot1agCfmPVStackMdLevel,
|
|
tmnxDot1agCfmPVStackDirection
|
|
}
|
|
::= { tmnxDot1agCfmPVStackTable 1 }
|
|
|
|
TmnxDot1agCfmPVStackEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmPVStackifIndex InterfaceIndex,
|
|
tmnxDot1agCfmPVStackVlanIdOrNone Unsigned32,
|
|
tmnxDot1agCfmPVStackPriVlanId Unsigned32,
|
|
tmnxDot1agCfmPVStackMdLevel Dot1agCfmMDLevel,
|
|
tmnxDot1agCfmPVStackDirection Dot1agCfmMpDirection,
|
|
tmnxDot1agCfmPVStackMdIndex Unsigned32,
|
|
tmnxDot1agCfmPVStackMaIndex Unsigned32,
|
|
tmnxDot1agCfmPVStackMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmPVStackMacAddress MacAddress
|
|
}
|
|
|
|
tmnxDot1agCfmPVStackifIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the Bridge Port or aggregated port
|
|
on which MEPs or MHFs might be configured."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:a"
|
|
::= { tmnxDot1agCfmPVStackEntry 1 }
|
|
|
|
tmnxDot1agCfmPVStackVlanIdOrNone OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID to which the MP is attached, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clauses 12.14.2.1.2:d, 22.1.7"
|
|
::= { tmnxDot1agCfmPVStackEntry 2 }
|
|
|
|
tmnxDot1agCfmPVStackPriVlanId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The Primary VLAN ID with which the Maintenance Association is
|
|
associated."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.6.1.3:b"
|
|
::= { tmnxDot1agCfmPVStackEntry 3 }
|
|
|
|
tmnxDot1agCfmPVStackMdLevel OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMDLevel
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MD Level of the Maintenance Point."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:b"
|
|
::= { tmnxDot1agCfmPVStackEntry 4 }
|
|
|
|
tmnxDot1agCfmPVStackDirection OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMpDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Direction in which the MP faces on the Bridge Port"
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:c"
|
|
::= { tmnxDot1agCfmPVStackEntry 5 }
|
|
|
|
tmnxDot1agCfmPVStackMdIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the Maintenance Domain in the dot1agCfmMdTable to which
|
|
the MP is associated, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:b"
|
|
::= { tmnxDot1agCfmPVStackEntry 6 }
|
|
|
|
tmnxDot1agCfmPVStackMaIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The index of the MA in the dot1agCfmMaNetTable and
|
|
dot1agCfmMaCompTable to which the MP is associated, or 0, if none."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:c"
|
|
::= { tmnxDot1agCfmPVStackEntry 7 }
|
|
|
|
tmnxDot1agCfmPVStackMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"If an MEP is configured, the MEPID, else 0"
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:d"
|
|
::= { tmnxDot1agCfmPVStackEntry 8 }
|
|
|
|
tmnxDot1agCfmPVStackMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"MAC address of the MP."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.3:e"
|
|
::= { tmnxDot1agCfmPVStackEntry 9 }
|
|
|
|
tmnxDot1agCfmSdpPVStackTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmSdpPVStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmSdpPVStackTable contains a read-only copy of the locally
|
|
configured information for Maintenance Points (MPs) hosted by Service
|
|
Delivery Point (SDP) bindings with Ethernet CFM Primary VLAN support
|
|
enabled.
|
|
|
|
The table is modeled after IEEE8021-CFM-MIB::dot1agCfmStackTable (with
|
|
extensions for SDP binding support and Primary VLAN support).
|
|
|
|
tmnxDot1agCfmPVStackTable is the equivalent table for Service Access
|
|
Points (SAPs)."
|
|
REFERENCE
|
|
"IEEE Std 802.1Q-2014, 'Bridges and Bridged Networks', Section 12.14.2,
|
|
'CFM Stack managed object'."
|
|
::= { tmnxDot1agCfmStack 5 }
|
|
|
|
tmnxDot1agCfmSdpPVStackEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmSdpPVStackEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmSdpPVStackEntry contains a read-only copy of the locally
|
|
configured information for an MP direction (e.g. MEPID=1, domain=2,
|
|
association=3, direction=down), if a) the MP direction is hosted by an
|
|
SDP binding, and b) the MP direction has Primary VLAN support enabled.
|
|
|
|
A row is created by SROS when an MP direction (hosted by an SDP
|
|
binding) has Primary VLAN support enabled.
|
|
|
|
A row is destroyed by SROS when an MP direction (hosted by an SDP
|
|
binding) is destroyed (provided the MP direction had Primary VLAN
|
|
support enabled)."
|
|
REFERENCE
|
|
"IEEE Std 802.1Q-2014, 'Bridges and Bridged Networks', Section 3,
|
|
'Definitions'."
|
|
INDEX {
|
|
tmnxDot1agCfmSdpPVStackSdpId,
|
|
tmnxDot1agCfmSdpPVStackVcId,
|
|
tmnxDot1agCfmSdpPVStackPriVlanId,
|
|
tmnxDot1agCfmSdpPVStackMdLevel,
|
|
tmnxDot1agCfmSdpPVStackDirection
|
|
}
|
|
::= { tmnxDot1agCfmSdpPVStackTable 1 }
|
|
|
|
TmnxDot1agCfmSdpPVStackEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmSdpPVStackSdpId SdpId,
|
|
tmnxDot1agCfmSdpPVStackVcId Unsigned32,
|
|
tmnxDot1agCfmSdpPVStackPriVlanId VlanId,
|
|
tmnxDot1agCfmSdpPVStackMdLevel Dot1agCfmMDLevel,
|
|
tmnxDot1agCfmSdpPVStackDirection Dot1agCfmMpDirection,
|
|
tmnxDot1agCfmSdpPVStackMdIndex Unsigned32,
|
|
tmnxDot1agCfmSdpPVStackMaIndex Unsigned32,
|
|
tmnxDot1agCfmSdpPVStackMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmSdpPVStackMacAddr MacAddress
|
|
}
|
|
|
|
tmnxDot1agCfmSdpPVStackSdpId OBJECT-TYPE
|
|
SYNTAX SdpId (1..32767)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackSdpId specifies the SDP identifier
|
|
index of the row."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 1 }
|
|
|
|
tmnxDot1agCfmSdpPVStackVcId OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..4294967295)
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackVcId specifies the Virtual Circuit
|
|
(VC) identifier index of the row. Together,
|
|
tmnxDot1agCfmSdpPVStackSdpId and tmnxDot1agCfmSdpPVStackVcId identify
|
|
an SDP binding."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 2 }
|
|
|
|
tmnxDot1agCfmSdpPVStackPriVlanId OBJECT-TYPE
|
|
SYNTAX VlanId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackPriVlanId specifies the Primary
|
|
VLAN identifier index of the row."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 3 }
|
|
|
|
tmnxDot1agCfmSdpPVStackMdLevel OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMDLevel
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackMdLevel specifies the Maintenance
|
|
Domain Level index of the row."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 4 }
|
|
|
|
tmnxDot1agCfmSdpPVStackDirection OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMpDirection
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackDirection specifies the MP
|
|
direction index (e.g. 'down(1)') of the row."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 5 }
|
|
|
|
tmnxDot1agCfmSdpPVStackMdIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackMdIndex indicates the Maintenance
|
|
Domain for the specified MP direction.
|
|
|
|
Zero is returned in the case of a MIP created using a default domain
|
|
with dot1agCfmDefaultMdMhfCreation set to 'defMHFdefault(2)' or
|
|
'defMHFexplicit(3)'."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 6 }
|
|
|
|
tmnxDot1agCfmSdpPVStackMaIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackMaIndex indicates the Maintenance
|
|
Association for the specified MP direction.
|
|
|
|
Zero is returned in the case of a MIP created using a default domain
|
|
with dot1agCfmDefaultMdMhfCreation set to 'defMHFdefault(2)' or
|
|
'defMHFexplicit(3)'."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 7 }
|
|
|
|
tmnxDot1agCfmSdpPVStackMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackMepId indicates the MEPID for the
|
|
specified MP direction.
|
|
|
|
Zero indicates the MP is a MIP."
|
|
REFERENCE
|
|
"IEEE Std 802.1Q-2014, 'Bridges and Bridged Networks', Section 3,
|
|
'Definitions'."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 8 }
|
|
|
|
tmnxDot1agCfmSdpPVStackMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpPVStackMacAddr indicates the MAC address
|
|
for the specified MP direction.
|
|
|
|
If no MAC address has been locally configured against the MP
|
|
direction, the all-zeros MAC address is returned."
|
|
::= { tmnxDot1agCfmSdpPVStackEntry 9 }
|
|
|
|
tmnxDot1agCfmGlobalObjs OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 2 }
|
|
|
|
tmnxDot1agCfmMcLagConfigGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 1 }
|
|
|
|
tmnxDot1agCfmMcLagStdbyInactive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMcLagStdbyInactive specifies whether or not
|
|
ETH-CFM MEPs configured on Multi-Chassis LAG ports are aware of MC-LAG
|
|
port active/standby states.
|
|
|
|
When this object is 'true (1)', MEPs configured on a Multi-Chassis LAG
|
|
port will act as if they are administratively shutdown if running on a
|
|
standby port, and will only be operational on an active MC-LAG port.
|
|
|
|
When this object is 'false (2)', MEPs configured on a Multi-Chassis
|
|
LAG port will operate regardless of the MC-LAG port active and standby
|
|
states."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMcLagConfigGroup 1 }
|
|
|
|
tmnxDot1agCfmMcLagPropHoldTime OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..60)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMcLagPropHoldTime specifies the duration, in
|
|
seconds, of a timer that is activated when an MC-LAG port or protocol
|
|
changes state. While the timer is active, no fault set or clear is
|
|
propagated to the MC-LAG SAP's CFM MEP.
|
|
|
|
The outstanding hold time can be monitored by polling the value of
|
|
sapEthCfmMcLagPropHoldTimeRemain for a particular SAP. When set to
|
|
the value zero (0), no delay in response to a port or protocol change
|
|
will be observed.
|
|
|
|
This object is meaningful only when tmnxDot1agCfmMcLagStdbyInactive is
|
|
set to the value 'enabled (1)', otherwise an SNMP Set operation will
|
|
result in an inconsistentValue error and the result of an SNMP Get
|
|
operation will be undefined."
|
|
DEFVAL { 1 }
|
|
::= { tmnxDot1agCfmMcLagConfigGroup 2 }
|
|
|
|
tmnxDot1agCfmSLMConfigGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 2 }
|
|
|
|
tmnxDot1agCfmSLMInactivityTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (10..100)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSLMInactivityTimer specifies the duration,
|
|
in seconds, that the system will maintain Synthetic Loss Measurement
|
|
(SLM) reply (SLR) data for individual two-way tests in the absence of
|
|
receiving SLM frames.
|
|
|
|
The system may be blocked in responding to new two-way SLM tests due
|
|
to an excessive inactive timer duration. In this case, reducing this
|
|
object's value, thus reducing the retention time for existing latent
|
|
SLR test data, will help free test resources allowing the system to
|
|
respond to new two-way SLM tests."
|
|
REFERENCE
|
|
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)
|
|
Section 8.2 Note 2."
|
|
DEFVAL { 100 }
|
|
::= { tmnxDot1agCfmSLMConfigGroup 1 }
|
|
|
|
tmnxDot1agCfmStatisticsGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 3 }
|
|
|
|
tmnxDot1agCfmGlobalPacketStats OBJECT IDENTIFIER ::= { tmnxDot1agCfmStatisticsGroup 1 }
|
|
|
|
tmnxDot1agCfmGlobalPacketRxCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmGlobalPacketRxCount indicates the number of
|
|
received ETH-CFM packets."
|
|
::= { tmnxDot1agCfmGlobalPacketStats 1 }
|
|
|
|
tmnxDot1agCfmGlobalPacketTxCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmGlobalPacketTxCount indicates the number of
|
|
transmitted ETH-CFM packets."
|
|
::= { tmnxDot1agCfmGlobalPacketStats 2 }
|
|
|
|
tmnxDot1agCfmGlobalPacketDropped OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmGlobalPacketDropped indicates the number of
|
|
packets dropped by ETH-CFM. A packet is dropped because of resource
|
|
contention."
|
|
::= { tmnxDot1agCfmGlobalPacketStats 3 }
|
|
|
|
tmnxDot1agCfmGlobalPacketDiscard OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmGlobalPacketDiscard indicates the number of
|
|
packets discarded by ETH-CFM. A packet may be discarded for several
|
|
reasons including, but not limited to, malformed PDU, invalid TLVs,
|
|
MEP admin down, etc."
|
|
::= { tmnxDot1agCfmGlobalPacketStats 4 }
|
|
|
|
tmnxDot1agCfmGlobalAisTxActive OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "sessions"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmGlobalAisTxActive indicates the number of
|
|
sessions where fault (AIS or other) is actively being transmitted."
|
|
::= { tmnxDot1agCfmGlobalPacketStats 5 }
|
|
|
|
tmnxDot1agCfmGlobalAisTxFail OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "sessions"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmGlobalAisTxFail indicates the number of
|
|
sessions where fault (AIS or other) can't be transmitted due to lack
|
|
of resources."
|
|
::= { tmnxDot1agCfmGlobalPacketStats 6 }
|
|
|
|
tmnxDot1agCfmComponentLimitTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmComponentLimitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmComponentLimitTable stores the current resource
|
|
counts as well as their resource limits for Ethernet Connectivity
|
|
Fault Management (ETH-CFM) components in the SROS series system."
|
|
::= { tmnxDot1agCfmStatisticsGroup 2 }
|
|
|
|
tmnxDot1agCfmComponentLimitEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmComponentLimitEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmComponentLimitEntry consists of the resource limits
|
|
for a particular component of ETH-CFM.
|
|
|
|
Rows are managed by the system and can not be created or destroyed
|
|
using SNMP set requests."
|
|
INDEX {
|
|
tmnxDot1agCfmCompMajorIndex,
|
|
tmnxDot1agCfmCompMinorIndex
|
|
}
|
|
::= { tmnxDot1agCfmComponentLimitTable 1 }
|
|
|
|
TmnxDot1agCfmComponentLimitEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmCompMajorIndex Unsigned32,
|
|
tmnxDot1agCfmCompMinorIndex Unsigned32,
|
|
tmnxDot1agCfmCompName TNamedItem,
|
|
tmnxDot1agCfmCompResourceUsage Unsigned32,
|
|
tmnxDot1agCfmCompResourceLimit Unsigned32
|
|
}
|
|
|
|
tmnxDot1agCfmCompMajorIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmCompMajorIndex specifies the major
|
|
identifier of the ETH-CFM component."
|
|
::= { tmnxDot1agCfmComponentLimitEntry 1 }
|
|
|
|
tmnxDot1agCfmCompMinorIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmCompMinorIndex specifies the minor
|
|
identifier of the ETH-CFM component."
|
|
::= { tmnxDot1agCfmComponentLimitEntry 2 }
|
|
|
|
tmnxDot1agCfmCompName OBJECT-TYPE
|
|
SYNTAX TNamedItem
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmCompName indicates the name of the ETH-CFM
|
|
component."
|
|
::= { tmnxDot1agCfmComponentLimitEntry 3 }
|
|
|
|
tmnxDot1agCfmCompResourceUsage OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmCompResourceUsage indicates the current
|
|
resource usage for the ETH-CFM component."
|
|
::= { tmnxDot1agCfmComponentLimitEntry 4 }
|
|
|
|
tmnxDot1agCfmCompResourceLimit OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmCompResourceLimit indicates the maximum
|
|
resource usage limit for the ETH-CFM component for the SROS series
|
|
system."
|
|
::= { tmnxDot1agCfmComponentLimitEntry 5 }
|
|
|
|
tmnxDot1agCfmGlobalOpcodeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmGlobalOpcodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmGlobalOpcodeTable consists of global statistics that are
|
|
kept in the receive and transmit direction on the node for each CFM
|
|
PDU Opcode."
|
|
REFERENCE
|
|
"Y.1731 clauses 8 and 9"
|
|
::= { tmnxDot1agCfmStatisticsGroup 3 }
|
|
|
|
tmnxDot1agCfmGlobalOpcodeEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmGlobalOpcodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Global Opcode Stats Table entry."
|
|
INDEX { tmnxDot1agCfmGlobalOpcode }
|
|
::= { tmnxDot1agCfmGlobalOpcodeTable 1 }
|
|
|
|
TmnxDot1agCfmGlobalOpcodeEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmGlobalOpcode Dot1agCfmStatisticOpcodeName,
|
|
tmnxDot1agCfmGlobalOpcodeRx Counter32,
|
|
tmnxDot1agCfmGlobalOpcodeTx Counter32
|
|
}
|
|
|
|
tmnxDot1agCfmGlobalOpcode OBJECT-TYPE
|
|
SYNTAX Dot1agCfmStatisticOpcodeName
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Integer that defines which CFM PDU Opcode the statistics refer to."
|
|
::= { tmnxDot1agCfmGlobalOpcodeEntry 1 }
|
|
|
|
tmnxDot1agCfmGlobalOpcodeRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of PDUs received on the node with the specified
|
|
Opcode."
|
|
::= { tmnxDot1agCfmGlobalOpcodeEntry 2 }
|
|
|
|
tmnxDot1agCfmGlobalOpcodeTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of PDUs transmitted from the node with the specified
|
|
Opcode."
|
|
::= { tmnxDot1agCfmGlobalOpcodeEntry 3 }
|
|
|
|
tmnxDot1agCfmSystemScalarsGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 4 }
|
|
|
|
tmnxDot1agCfmGraceTxEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmGraceTxEnable specifies whether or not grace
|
|
period notifications will be sent to the ETH-CFM remote MEP peers. The
|
|
value 'true' enables grace period notifications, and the value 'false'
|
|
suppresses the notifications.
|
|
|
|
During an outage, the modification of this object from 'true' to
|
|
'false' will cause an immediate clear of all grace period
|
|
notifications, after which no further notifications will be sent. A
|
|
modification of this object from 'false' to 'true' will not enable the
|
|
transmission of grace period for any outages currently in progress but
|
|
will take effect for subsequent outages."
|
|
DEFVAL { true }
|
|
::= { tmnxDot1agCfmSystemScalarsGroup 1 }
|
|
|
|
tmnxDot1agCfmGracePeriod OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmGracePeriod indicates whether or not the
|
|
node is locally executing a grace period. A value of 'true' indicates
|
|
that all peer timeouts are extended locally and eligible MEPs are
|
|
transmitting grace period information. A value of 'false' indicates
|
|
no grace period information is transmitted and standard values are
|
|
used for timing out remote peers.
|
|
|
|
Note that for a local MEP to be eligible for grace period transmission
|
|
it must be admin up and ccm-enabled. Additionally, for any
|
|
transmission to occur tmnxDot1agCfmGraceTxEnable must be set to
|
|
'true'."
|
|
::= { tmnxDot1agCfmSystemScalarsGroup 2 }
|
|
|
|
tmnxDot1agCfmSenderIdType OBJECT-TYPE
|
|
SYNTAX LldpChassisIdSubtype
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSenderIdType specifies the type of sender
|
|
identification that is transmitted in CFM PDUs generated from this
|
|
system.
|
|
|
|
The value of 'chassisComponent (1)' indicates that the system's name
|
|
(TIMETRA-CHASSIS-MIB::tmnxChassisName) is inserted in transmitted
|
|
PDUs, while 'local (7)' indicates that the value as defined in
|
|
tmnxDot1agCfmSenderIdName is transmitted."
|
|
DEFVAL { chassisComponent }
|
|
::= { tmnxDot1agCfmSystemScalarsGroup 3 }
|
|
|
|
tmnxDot1agCfmSenderIdName OBJECT-TYPE
|
|
SYNTAX OCTET STRING (SIZE (0..45))
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSenderIdName specifies the locally defined
|
|
sender-id name that is inserted in all CFM transmitted PDUs. The value
|
|
of this object is only meaningful if the value of
|
|
tmnxDot1agCfmSenderIdType is set to the value 'local (7)'. Otherwise
|
|
the value of this object MUST be the empty string.
|
|
|
|
The value of this object MUST be set to a non-empty string in the same
|
|
SNMP PDU as the modification of tmnxDot1agCfmSenderIdType when the
|
|
type is assigned to the value 'local (7)'. Modification of the type
|
|
away from 'local (7)' will automatically reset the value to its
|
|
default value."
|
|
DEFVAL { "" }
|
|
::= { tmnxDot1agCfmSystemScalarsGroup 4 }
|
|
|
|
tmnxDot1agAutoIndexGroup OBJECT IDENTIFIER ::= { tmnxDot1agCfmGlobalObjs 5 }
|
|
|
|
tmnxDot1agAutoMdIndexRangeStart OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMdIndexOrNone
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agAutoMdIndexRangeStart specifies start of the CFM
|
|
Maintenance Domain index range to be used in model-driven user
|
|
interfaces"
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agAutoIndexGroup 1 }
|
|
|
|
tmnxDot1agAutoMdIndexRangeEnd OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMdIndexOrNone
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agAutoMdIndexRangeEnd specifies end of the CFM Maintenance
|
|
Domain index range to be used in model-driven user interfaces."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agAutoIndexGroup 2 }
|
|
|
|
tmnxDot1agAutoMaIndexRangeStart OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaIndexOrNone
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agAutoMaIndexRangeStart specifies the start of the CFM
|
|
Maintenance Association index range to be used in model-driven user
|
|
interfaces"
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agAutoIndexGroup 3 }
|
|
|
|
tmnxDot1agAutoMaIndexRangeEnd OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaIndexOrNone
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agAutoMaIndexRangeEnd specifies the end of the CFM
|
|
Maintenance Association index range to be used in model-driven user
|
|
interfaces."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agAutoIndexGroup 4 }
|
|
|
|
tmnxDot1agCfmManagementObjects OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 3 }
|
|
|
|
tmnxDot1agCfmMepMgmtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepMgmtTable manages the row creation and deletion of
|
|
dot1agCfmMepTable rows. This table replaces the standard row creation
|
|
model for Dot1ag CFM MEPs to better facilitate Nokia SROS series
|
|
requirements. The use of writing to the
|
|
IEEE-8021-CFM-MIB::dot1agCfmMepRowStatus object is deprecated and
|
|
should be discouraged in favor of this table."
|
|
::= { tmnxDot1agCfmManagementObjects 1 }
|
|
|
|
tmnxDot1agCfmMepMgmtEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepMgmtEntry consists of the configuration objects
|
|
used for the purpose of row creation for Nokia SROS Dot1ag MEPs. To
|
|
create a MEP one must specify its type and endpoint association."
|
|
AUGMENTS { dot1agCfmMepEntry }
|
|
::= { tmnxDot1agCfmMepMgmtTable 1 }
|
|
|
|
TmnxDot1agCfmMepMgmtEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepMgmtRowStatus RowStatus,
|
|
tmnxDot1agCfmMepMgmtType INTEGER,
|
|
tmnxDot1agCfmMepMgmtServiceId TmnxServId,
|
|
tmnxDot1agCfmMepMgmtIfIndex InterfaceIndexOrZero,
|
|
tmnxDot1agCfmMepMgmtPrimaryVid Unsigned32,
|
|
tmnxDot1agCfmMepMgmtSdpId SdpId,
|
|
tmnxDot1agCfmMepMgmtVcId Unsigned32,
|
|
tmnxDot1agCfmMepMgmtFcltyIfIndex InterfaceIndexOrZero,
|
|
tmnxDot1agCfmMepMgmtFcltyVlanId VlanIdOrNone,
|
|
tmnxDot1agCfmMepMgmtDirection Dot1agCfmMpDirection
|
|
}
|
|
|
|
tmnxDot1agCfmMepMgmtRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtRowStatus specifies the row status of
|
|
the dot1ag CFM MEP. This object replaces the use of the
|
|
IEEE-8021-CFM-MIB::dot1agCfmMepRowStatus object."
|
|
::= { tmnxDot1agCfmMepMgmtEntry 1 }
|
|
|
|
tmnxDot1agCfmMepMgmtType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
default (0),
|
|
facilityPort (1),
|
|
facilityInterface (2),
|
|
sapPrimaryVlan (3),
|
|
sdpPrimaryVlan (4)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtType specifies the type of the
|
|
specified MEP.
|
|
|
|
Code Points
|
|
-----------
|
|
default(0)
|
|
The MEP resides on a Service Access Point (SAP) or Service Delivery
|
|
Point (SDP) binding. The MEP has primary VLAN processing disabled.
|
|
OR
|
|
The MEP resides on a service.
|
|
facilityPort(1)
|
|
The MEP resides on a port or a Link Aggregation Group (LAG).
|
|
facilityInterface(2)
|
|
The MEP resides on a router interface.
|
|
sapPrimaryVlan(3)
|
|
The MEP resides on a SAP. The MEP has primary VLAN processing
|
|
enabled. This code point is rejected if the MEP's
|
|
IEEE8021-CFM-MIB::dot1agCfmMaCompPrimaryVlanId is zero.
|
|
sdpPrimaryVlan(4)
|
|
The MEP resides on an SDP binding. The MEP has primary VLAN
|
|
processing enabled. This code point is rejected if the MEP's
|
|
IEEE8021-CFM-MIB::dot1agCfmMaCompPrimaryVlanId is zero.
|
|
|
|
This object must be specified during row creation."
|
|
DEFVAL { default }
|
|
::= { tmnxDot1agCfmMepMgmtEntry 2 }
|
|
|
|
tmnxDot1agCfmMepMgmtServiceId OBJECT-TYPE
|
|
SYNTAX TmnxServId
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtServiceId specifies the service to
|
|
which the virtual MEP is attached.
|
|
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepSvcId.
|
|
|
|
This object may be specified during row creation when
|
|
tmnxDot1agCfmMepMgmtType is set to the value 'default'."
|
|
::= { tmnxDot1agCfmMepMgmtEntry 3 }
|
|
|
|
tmnxDot1agCfmMepMgmtIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtIfIndex specifies, along with
|
|
tmnxDot1agCfmMepMgmtPrimaryVid, the interface index of the interface
|
|
to which the MEP is attached.
|
|
|
|
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMepIfIndex.
|
|
|
|
This object may be specified during row creation when
|
|
tmnxDot1agCfmMepMgmtType is set to either the value 'default' or
|
|
'sapPrimaryVlan'."
|
|
::= { tmnxDot1agCfmMepMgmtEntry 4 }
|
|
|
|
tmnxDot1agCfmMepMgmtPrimaryVid OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtPrimaryVid specifies, along with
|
|
tmnxDot1agCfmMepMgmtIfIndex, the Primary VID of the MEP.
|
|
|
|
This object refers directly to
|
|
IEEE8021-CFM-MIB::dot1agCfmMepPrimaryVid.
|
|
|
|
This object must be specified during row creation when
|
|
tmnxDot1agCfmMepMgmtIfIndex is specified."
|
|
::= { tmnxDot1agCfmMepMgmtEntry 5 }
|
|
|
|
tmnxDot1agCfmMepMgmtSdpId OBJECT-TYPE
|
|
SYNTAX SdpId
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtSdpId specifies, along with
|
|
tmnxDot1agCfmMepMgmtVcId, the SDP-Binding to which the MEP is
|
|
attached.
|
|
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepSdpId.
|
|
|
|
This object may be specified during row creation when
|
|
tmnxDot1agCfmMepMgmtType is set to the value 'default'."
|
|
::= { tmnxDot1agCfmMepMgmtEntry 6 }
|
|
|
|
tmnxDot1agCfmMepMgmtVcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtVcId specifies, along with
|
|
tmnxDot1agCfmMepMgmtSdpId, the SDP-Binding to which the MEP is
|
|
attached.
|
|
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepVcId.
|
|
|
|
This object must be specified during row creation when
|
|
tmnxDot1agCfmMepMgmtSdpId is specified."
|
|
::= { tmnxDot1agCfmMepMgmtEntry 7 }
|
|
|
|
tmnxDot1agCfmMepMgmtFcltyIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtFcltyIfIndex specifies, along with
|
|
tmnxDot1agCfmMepMgmtFcltyVlanId, the port or interface to which this
|
|
MEP is attached.
|
|
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepFacilityIfIndex.
|
|
|
|
This object must be specified during row creation when
|
|
tmnxDot1agCfmMepMgmtType is set to a 'facility' value."
|
|
::= { tmnxDot1agCfmMepMgmtEntry 8 }
|
|
|
|
tmnxDot1agCfmMepMgmtFcltyVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrNone
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtFcltyVlanId specifies, along with
|
|
tmnxDot1agCfmMepMgmtFcltyIfIndex, the port or interface to which this
|
|
MEP is attached.
|
|
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMepFacilityVlanId.
|
|
|
|
This object must be specified during row creation when
|
|
tmnxDot1agCfmMepMgmtFcltyIfIndex is specified."
|
|
::= { tmnxDot1agCfmMepMgmtEntry 9 }
|
|
|
|
tmnxDot1agCfmMepMgmtDirection OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMpDirection
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMgmtDirection specifies the direction in
|
|
which the MEP faces on the Bridge port.
|
|
|
|
This object refers directly to
|
|
IEEE8021-CFM-MIB::dot1agCfmMepDirection.
|
|
|
|
This object applies to any MEP type as specified by the object
|
|
tmnxDot1agCfmMepMgmtType."
|
|
DEFVAL { down }
|
|
::= { tmnxDot1agCfmMepMgmtEntry 50 }
|
|
|
|
tmnxDot1agCfmMd OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 5 }
|
|
|
|
tmnxDot1agCfmMdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMdTable extends the functionality of the
|
|
dot1agCfmMdTable for the SROS series systems."
|
|
::= { tmnxDot1agCfmMd 1 }
|
|
|
|
tmnxDot1agCfmMdEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMdEntry consists of the objects used to enhance the
|
|
Maintenance Domain functionality.
|
|
|
|
Use of AUGMENTS clause implies a one-to-one dependent relationship
|
|
between the base table, dot1agCfmMdTable, and the augmenting table,
|
|
tmnxDot1agCfmMdTable. This in effect extends the dot1agCfmMdTable with
|
|
additional columns.
|
|
|
|
Creation (or deletion) of a row in the dot1agCfmMdTable results in the
|
|
same fate for the row in the tmnxDot1agCfmMdTable."
|
|
AUGMENTS { dot1agCfmMdEntry }
|
|
::= { tmnxDot1agCfmMdTable 1 }
|
|
|
|
TmnxDot1agCfmMdEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMdCreationOrigin TmnxCreateOrigin,
|
|
tmnxDot1agCfmMdAdminName TLNamedItemOrEmpty
|
|
}
|
|
|
|
tmnxDot1agCfmMdCreationOrigin OBJECT-TYPE
|
|
SYNTAX TmnxCreateOrigin
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMdCreationOrigin indicates the mechanism
|
|
which created this CFM Maintenance Domain."
|
|
::= { tmnxDot1agCfmMdEntry 1 }
|
|
|
|
tmnxDot1agCfmMdAdminName OBJECT-TYPE
|
|
SYNTAX TLNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMdAdminName indicates a name that can be
|
|
used to uniquely identify a CFM Maintenance Domain. Historically, only
|
|
the arbitrary integer index, dot1agCfmMdIndex, would be used for this
|
|
purpose. A string provides greater flexibility and allows some amount
|
|
of context to also be included."
|
|
DEFVAL { ''H }
|
|
::= { tmnxDot1agCfmMdEntry 2 }
|
|
|
|
tmnxDot1agCfmMa OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 6 }
|
|
|
|
tmnxDot1agCfmMaNetTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMaNetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaNetTable AUGMENTS the standard MIB table,
|
|
dot1agCfmMaNetTable. This table is used to enhance Maintenance
|
|
Association functionality for Ethernet Connectivity Fault Management
|
|
(ETH-CFM)."
|
|
::= { tmnxDot1agCfmMa 1 }
|
|
|
|
tmnxDot1agCfmMaNetEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaNetEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaNetEntry consists of the configuration objects used
|
|
to enhance the Maintenance Association functionality."
|
|
AUGMENTS { dot1agCfmMaNetEntry }
|
|
::= { tmnxDot1agCfmMaNetTable 1 }
|
|
|
|
TmnxDot1agCfmMaNetEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMaNetHoldDownTimer Unsigned32,
|
|
tmnxDot1agCfmMaNetTotalMEPCount Counter32,
|
|
tmnxDot1agCfmMaNetAutoDiscAdmin TruthValue,
|
|
tmnxDot1agCfmMaNetIdPermission TmnxDot1agCfmIdPermission,
|
|
tmnxDot1agCfmMaNetAdminName TLNamedItemOrEmpty
|
|
}
|
|
|
|
tmnxDot1agCfmMaNetHoldDownTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 1..1000)
|
|
UNITS "centiseconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaNetHoldDownTimer specifies the time, in
|
|
centiseconds, that a MEP in the association will delay declaring a
|
|
fault. This delay is added on to the existing
|
|
3.5 * dot1agCfmMaNetCcmInterval value used to determine if a
|
|
connectivity fault to the peer should be raised.
|
|
|
|
A value of zero (0) indicates that no additional delay should be added
|
|
to the existing 3.5 * dot1agCfmMaNetCcmInterval value."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMaNetEntry 1 }
|
|
|
|
tmnxDot1agCfmMaNetTotalMEPCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaNetTotalMEPCount indicates the number of
|
|
unique MEPs configured (both local and remote) that are associated
|
|
with this MA.
|
|
|
|
When the number of MEPs exceed the normal MA limits, the MA is
|
|
considered to be an extended MA and will use a resource from the
|
|
'Extended MA' resource entry in tmnxDot1agCfmComponentLimitTable."
|
|
::= { tmnxDot1agCfmMaNetEntry 2 }
|
|
|
|
tmnxDot1agCfmMaNetAutoDiscAdmin OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaNetAutoDiscAdmin specifies if remote MEP
|
|
automatic discovery is enabled in the association. A value of 'true'
|
|
indicates that a new remote MEP entry will be added to the
|
|
dot1agCfmMepDbTable when the node receives a CCM PDU from a remote
|
|
MEP that is not yet in that table (up to the maximum limit of MEPs
|
|
allowed in the association). A value of 'false' indicates that remote
|
|
MEPs must be manually configured in the association
|
|
dot1agCfmMaMepListTable before being added to the association
|
|
dot1agCfmMepDbTable."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMaNetEntry 3 }
|
|
|
|
tmnxDot1agCfmMaNetIdPermission OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmIdPermission
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"Enumerated value indicating what, if anything, is to be included in
|
|
the Sender ID TLV (21.5.3) transmitted by MPs configured in this MA.
|
|
This object is configurable on MA entries that do not consist of
|
|
component entries."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.6.1.3:d"
|
|
DEFVAL { sendIdNone }
|
|
::= { tmnxDot1agCfmMaNetEntry 4 }
|
|
|
|
tmnxDot1agCfmMaNetAdminName OBJECT-TYPE
|
|
SYNTAX TLNamedItemOrEmpty
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaNetAdminName indicates a name that can be
|
|
used to uniquely identify a CFM Maintenance Association. Historically,
|
|
only the arbitrary integer index, dot1agCfmMaIndex, would be used for
|
|
this purpose. A string provides greater flexibility and allows some
|
|
amount of context to also be included."
|
|
DEFVAL { ''H }
|
|
::= { tmnxDot1agCfmMaNetEntry 5 }
|
|
|
|
tmnxDot1agCfmMaCompTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMaCompEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaCompTable AUGMENTS the standard MIB table,
|
|
dot1agCfmMaCompTable. This table is used to enhance Maintenance
|
|
Association functionality for Ethernet Connectivity Fault Management
|
|
(ETH-CFM)."
|
|
::= { tmnxDot1agCfmMa 2 }
|
|
|
|
tmnxDot1agCfmMaCompEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaCompEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaCompEntry consists of the configuration objects
|
|
used to enhance the Maintenance Association functionality."
|
|
AUGMENTS { dot1agCfmMaCompEntry }
|
|
::= { tmnxDot1agCfmMaCompTable 1 }
|
|
|
|
TmnxDot1agCfmMaCompEntry ::= SEQUENCE
|
|
{ tmnxDot1agCfmMaCompMipLtrPrio Unsigned32 }
|
|
|
|
tmnxDot1agCfmMaCompMipLtrPrio OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaCompMipLtrPrio specifies at what priority
|
|
the link-trace response frames should be transmitted for a MIP
|
|
request."
|
|
DEFVAL { 7 }
|
|
::= { tmnxDot1agCfmMaCompEntry 1 }
|
|
|
|
tmnxDot1agCfmMaMepListTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMaMepListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaMepListTable extends the functionality of the
|
|
dot1agCfmMaMepListTable for the SROS series systems."
|
|
::= { tmnxDot1agCfmMa 3 }
|
|
|
|
tmnxDot1agCfmMaMepListEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaMepListEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaMepListEntry augments the standard MIB entry for
|
|
the purpose of extending functionality for the SROS series systems for
|
|
the Dot1ag CFM MEP Lists. Rows are created and destroyed by the system
|
|
through the row status field in dot1agCfmMaMepListEntry."
|
|
AUGMENTS { dot1agCfmMaMepListEntry }
|
|
::= { tmnxDot1agCfmMaMepListTable 1 }
|
|
|
|
TmnxDot1agCfmMaMepListEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMaMepListMacAddress MacAddress,
|
|
tmnxDot1agCfmMaMepListAutoDiscvd TruthValue
|
|
}
|
|
|
|
tmnxDot1agCfmMaMepListMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMepListMacAddress specifies the target
|
|
unicast MAC address used for transmitting CFM packets to the remote
|
|
MEPs for the specified MEPID.
|
|
|
|
Setting a unicast MAC address restricts the number of MEPIDs that can
|
|
be configured for an individual MA to a maximum of one (1). Setting
|
|
the address back to the default value will remove this restriction and
|
|
will result in the regular CCM multicast address being used. This
|
|
value cannot be set to any multicast or broadcast address."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMaMepListEntry 1 }
|
|
|
|
tmnxDot1agCfmMaMepListAutoDiscvd OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMepListAutoDiscvd specifies whether or not
|
|
the remote peer was automatically discovered ('true') or not. Auto-
|
|
discovered remote peers are created by the system only and are of a
|
|
'volatile' storage type. Specifying the value of 'false' will mark an
|
|
auto-discovered remote peer as permanently configured.
|
|
|
|
To reset a configured remote peer to auto-discovered a manager must
|
|
destroy the corresponding dot1agCfmMaMepListEntry."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMaMepListEntry 2 }
|
|
|
|
tmnxDot1agCfmMep OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 7 }
|
|
|
|
tmnxDot1agCfmMepTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This table augments the Maintenance Association End Point (MEP) table
|
|
of the IEEE8021-CFM-MIB."
|
|
::= { tmnxDot1agCfmMep 1 }
|
|
|
|
tmnxDot1agCfmMepEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the tmnxDot1agCfmMepTable. This row exists only if
|
|
the association dot1agCfmMepEntry is active."
|
|
AUGMENTS { dot1agCfmMepEntry }
|
|
::= { tmnxDot1agCfmMepTable 1 }
|
|
|
|
TmnxDot1agCfmMepEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepSdpId SdpId,
|
|
tmnxDot1agCfmMepVcId Unsigned32,
|
|
tmnxDot1agCfmMepMacAddress MacAddress,
|
|
tmnxDot1agCfmMepAisEnable TruthValue,
|
|
tmnxDot1agCfmMepAisMegLevel BITS,
|
|
tmnxDot1agCfmMepAisPriority Unsigned32,
|
|
tmnxDot1agCfmMepAisInterval Unsigned32,
|
|
tmnxDot1agCfmMepEthRxAisInterval Unsigned32,
|
|
tmnxDot1agCfmMepEthRxAis TruthValue,
|
|
tmnxDot1agCfmMepEthAisTxCount Counter32,
|
|
tmnxDot1agCfmMepEthTestEnable TruthValue,
|
|
tmnxDot1agCfmMepEthTestPattern INTEGER,
|
|
tmnxDot1agCfmMepEthTestMacAddr MacAddress,
|
|
tmnxDot1agCfmMepEthTestDataLen Unsigned32,
|
|
tmnxDot1agCfmMepEthTestPriority Unsigned32,
|
|
tmnxDot1agCfmMepOWDTMacAddress MacAddress,
|
|
tmnxDot1agCfmMepOWDTPriority Unsigned32,
|
|
tmnxDot1agCfmMepTWDTMacAddress MacAddress,
|
|
tmnxDot1agCfmMepTWDTPriority Unsigned32,
|
|
tmnxDot1agCfmMepSvcId TmnxServId,
|
|
tmnxDot1agCfmMepControlMep TruthValue,
|
|
tmnxDot1agCfmMepEthTestThreshold Unsigned32,
|
|
tmnxDot1agCfmMepOWDTThreshold Unsigned32,
|
|
tmnxDot1agCfmMepFaultPropagation INTEGER,
|
|
tmnxDot1agCfmMepFacilityIfIndex InterfaceIndexOrZero,
|
|
tmnxDot1agCfmMepFacilityVlanId VlanIdOrNone,
|
|
tmnxDot1agCfmMepFacilityType INTEGER,
|
|
tmnxDot1agCfmMepFcltyFaultNotify TruthValue,
|
|
tmnxDot1agCfmMepDescription TItemDescription,
|
|
tmnxDot1agCfmMepMcLagInactive INTEGER,
|
|
tmnxDot1agCfmMepCcmPaddingSize Unsigned32,
|
|
tmnxDot1agCfmMepCcmIgnoreTLVs BITS,
|
|
tmnxDot1agCfmMepCsfEnable TruthValue,
|
|
tmnxDot1agCfmMepCsfRxMultiplier Unsigned32,
|
|
tmnxDot1agCfmMepCsfRxState INTEGER,
|
|
tmnxDot1agCfmMepCsfRxInterval Unsigned32,
|
|
tmnxDot1agCfmMepCsfRxCount Counter32,
|
|
tmnxDot1agCfmMepEthAisTxFail Counter32,
|
|
tmnxDot1agCfmMepTxLbmTimeout Unsigned32,
|
|
tmnxDot1agCfmMepTxLbmInterval Unsigned32,
|
|
tmnxDot1agCfmMepLbmPaddingSize Unsigned32,
|
|
tmnxDot1agCfmMepIfSupportEnable TruthValue,
|
|
tmnxDot1agCfmMepAisLowPrioDef Dot1agCfmLowestAlarmPri,
|
|
tmnxDot1agCfmMepCollectLmmStats TruthValue,
|
|
tmnxDot1agCfmMepCreationOrigin TmnxCreateOrigin,
|
|
tmnxDot1agCfmMepEthTestTargMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmMepEthTestLstDstMac MacAddress,
|
|
tmnxDot1agCfmMepOWDTTargetMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmMepOWDTLstDstMac MacAddress,
|
|
tmnxDot1agCfmMepTWDTTargetMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmMepTWDTLstDstMac MacAddress,
|
|
tmnxDot1agCfmMepCollLmmFcSts TFCSet,
|
|
tmnxDot1agCfmMepCollLmmFcStsInP TFCSet,
|
|
tmnxDot1agCfmMepTxEthVsmGrace TruthValue,
|
|
tmnxDot1agCfmMepRxEthVsmGrace TruthValue,
|
|
tmnxDot1agCfmMepTxEthEd TruthValue,
|
|
tmnxDot1agCfmMepRxEthEd TruthValue,
|
|
tmnxDot1agCfmMepEthEdMaxDurRx Unsigned32,
|
|
tmnxDot1agCfmMepEthEdPriority Integer32,
|
|
tmnxDot1agCfmMepLbmSvcActResp TruthValue,
|
|
tmnxDot1agCfmMepEthBnReceive TruthValue,
|
|
tmnxDot1agCfmMepEthBnRxUpdPacing Unsigned32,
|
|
tmnxDot1agCfmMepInstallMep TruthValue
|
|
}
|
|
|
|
tmnxDot1agCfmMepSdpId OBJECT-TYPE
|
|
SYNTAX SdpId
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSdpId specifies, along with the
|
|
tmnxDot1agCfmMepVcId, the SDP-Binding within a bridge port, to which
|
|
the MEP is attached.
|
|
|
|
This object is applicable to SDP-Bindings only, and MUST be set to the
|
|
null ID (0) when dot1agCfmMepIfIndex, dot1agCfmMepPrimaryVid,
|
|
tmnxDot1agCfmMepSvcId, tmnxDot1agCfmMepFacilityIfIndex,
|
|
tmnxDot1agCfmMepFacilityVlanId, or tmnxDot1agCfmMepFacilityType is
|
|
non-zero. When this object is applicable (non-zero), the above objects
|
|
MUST be set to zero (0).
|
|
|
|
Once set, this object can not be modified."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:a"
|
|
::= { tmnxDot1agCfmMepEntry 1 }
|
|
|
|
tmnxDot1agCfmMepVcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepVcId specifies, along with
|
|
tmnxDot1agCfmMepSdpId, the SDP Binding for the bridge.
|
|
|
|
tmnxDot1agCfmMepVcId is applicable to SDP-Bindings only, and MUST be
|
|
set to zero (0) when dot1agCfmMepIfIndex, dot1agCfmMepPrimaryVid
|
|
tmnxDot1agCfmMepSvcId, tmnxDot1agCfmMepFacilityIfIndex,
|
|
tmnxDot1agCfmMepFacilityVlanId, or tmnxDot1agCfmMepFacilityType is
|
|
non-zero. When this object is applicable (non-zero), the above objects
|
|
MUST be set to zero (0).
|
|
|
|
Once set, this object can not be modified."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.2.1.2:d"
|
|
::= { tmnxDot1agCfmMepEntry 2 }
|
|
|
|
tmnxDot1agCfmMepMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMacAddress specifies the MAC address that
|
|
is assigned to dot1agCfmMepMacAddress."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.7.1.3:i and 19.4"
|
|
::= { tmnxDot1agCfmMepEntry 3 }
|
|
|
|
tmnxDot1agCfmMepAisEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepAisEnable specifies whether AIS frames
|
|
are generated from the Maintenance Entity Group (MEG)."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 4 }
|
|
|
|
tmnxDot1agCfmMepAisMegLevel OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
level1 (0),
|
|
level2 (1),
|
|
level3 (2),
|
|
level4 (3),
|
|
level5 (4),
|
|
level6 (5),
|
|
level7 (6)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepAisMegLevel specifies the levels that
|
|
should be notified to suppress alarms resulting from defect conditions
|
|
detected by the MEP."
|
|
DEFVAL { {} }
|
|
::= { tmnxDot1agCfmMepEntry 5 }
|
|
|
|
tmnxDot1agCfmMepAisPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepAisPriority specifies at what priority
|
|
the AIS frames should be transmitted."
|
|
DEFVAL { 7 }
|
|
::= { tmnxDot1agCfmMepEntry 6 }
|
|
|
|
tmnxDot1agCfmMepAisInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1 | 60)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepAisInterval specifies at what intervals
|
|
to transmit AIS frames."
|
|
DEFVAL { 1 }
|
|
::= { tmnxDot1agCfmMepEntry 7 }
|
|
|
|
tmnxDot1agCfmMepEthRxAisInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1 | 60)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthRxAisInterval indicates the AIS
|
|
Interval received in the last AIS Frame."
|
|
DEFVAL { 1 }
|
|
::= { tmnxDot1agCfmMepEntry 8 }
|
|
|
|
tmnxDot1agCfmMepEthRxAis OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthRxAis indicates the MEP is receiving
|
|
AIS test frames from one or more of its sub-layer MEPs."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 9 }
|
|
|
|
tmnxDot1agCfmMepEthAisTxCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthAisTxCount indicates number of AIS
|
|
frames transmitted on the MEP."
|
|
::= { tmnxDot1agCfmMepEntry 10 }
|
|
|
|
tmnxDot1agCfmMepEthTestEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthTestEnable specifies whether Ethernet
|
|
test frames are to be generated on transmission or processed on
|
|
reception. If this object is set to 'false', then
|
|
tmnxDot1agCfmMepEthTestPattern is undefined.
|
|
|
|
When this object is set to 'true', tmnxDot1agCfmMepEthTestPattern is
|
|
reset to its default value, unless tmnxDot1agCfmMepEthTestPattern is
|
|
set to a specific value in the same SNMP PDU."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 11 }
|
|
|
|
tmnxDot1agCfmMepEthTestPattern OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
allZerosNoCrc (0),
|
|
allZerosCrc (1),
|
|
prbsNoCrc (2),
|
|
prbsCrc (3),
|
|
allOnesNoCrc (4),
|
|
allOnesCrc (5)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthTestPattern specifies the data-content
|
|
of the AIS test frames. 'allZerosNoCrc (0)' and 'allZerosCrc (1)'
|
|
specifies the data content as all zero values (without and with CRC
|
|
calculations respectively). 'prbsNoCrc (3) and 'prbsCrc (4) specifies
|
|
the data content as pseudo random bit sequence (without and with CRC
|
|
calculations respectively). 'allOnesNoCrc (4)' and 'allOnesCrc (5)',
|
|
specifies the data content as all ones (without and with CRC
|
|
calculations respectively).
|
|
|
|
This object is only applicable if tmnxDot1agCfmMepEthTestEnable is set
|
|
to 'true'."
|
|
DEFVAL { allZerosNoCrc }
|
|
::= { tmnxDot1agCfmMepEntry 12 }
|
|
|
|
tmnxDot1agCfmMepEthTestMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthTestMacAddr specifies the MAC address
|
|
of the target to whom the Eth-test frames are sent.
|
|
|
|
Setting this object will trigger the test frame to be sent. Once the
|
|
test is complete, the object will revert to the default value,
|
|
indicating that another test is possible."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepEntry 13 }
|
|
|
|
tmnxDot1agCfmMepEthTestDataLen OBJECT-TYPE
|
|
SYNTAX Unsigned32 (64..1500)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthTestDataLen specifies the length of
|
|
the data sent in an Eth-test frame. The contents of the data is
|
|
specified by the tmnxDot1agCfmMepEthTestPattern object."
|
|
DEFVAL { 64 }
|
|
::= { tmnxDot1agCfmMepEntry 14 }
|
|
|
|
tmnxDot1agCfmMepEthTestPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthTestPriority specifies the priority
|
|
used in generating Eth-Test frames."
|
|
DEFVAL { 7 }
|
|
::= { tmnxDot1agCfmMepEntry 15 }
|
|
|
|
tmnxDot1agCfmMepOWDTMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepOWDTMacAddress specifies the MAC address
|
|
used as a target for the One-Way-Delay Test (OWDT).
|
|
|
|
Setting this object will trigger a One-Way-Delay test to the specified
|
|
MAC address.
|
|
|
|
Upon completion of the test, the MacAddress will revert to its default
|
|
value, indicating that another test is possible."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepEntry 16 }
|
|
|
|
tmnxDot1agCfmMepOWDTPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepOWDTPriority specifies the priority used
|
|
in the generated test frame for the One-Way-Delay test."
|
|
DEFVAL { 7 }
|
|
::= { tmnxDot1agCfmMepEntry 17 }
|
|
|
|
tmnxDot1agCfmMepTWDTMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTWDTMacAddress specifies the MAC address
|
|
used as a target for the Two-Way-Delay Test (TWDT).
|
|
|
|
Setting this object will trigger a Two-Way-Delay test to the specified
|
|
MAC address.
|
|
|
|
Upon completion of the test, the MacAddress will revert to its default
|
|
value, indicating that another test is possible."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepEntry 18 }
|
|
|
|
tmnxDot1agCfmMepTWDTPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTWDTPriority specifies the priority used
|
|
in the generated test frame for the Two-Way-Delay test."
|
|
DEFVAL { 7 }
|
|
::= { tmnxDot1agCfmMepEntry 19 }
|
|
|
|
tmnxDot1agCfmMepSvcId OBJECT-TYPE
|
|
SYNTAX TmnxServId
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSvcId specifies the service to which the
|
|
virtual MEP is attached.
|
|
|
|
tmnxDot1agCfmMepSvcId is applicable to virtual MEPs only, and MUST
|
|
be set to zero (0) when dot1agCfmMepIfIndex, dot1agCfmMepPrimaryVid,
|
|
tmnxDot1agCfmMepSdpId, tmnxDot1agCfmMepVcId,
|
|
tmnxDot1agCfmMepFacilityIfIndex, tmnxDot1agCfmMepFacilityVlanId, or
|
|
tmnxDot1agCfmMepFacilityType is non-zero. When this object is
|
|
applicable (non-zero), the above objects MUST be set to zero (0).
|
|
|
|
Once set, this object can not be modified."
|
|
::= { tmnxDot1agCfmMepEntry 20 }
|
|
|
|
tmnxDot1agCfmMepControlMep OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepControlMep specifies whether or not the
|
|
operational state of the MEP is used by the management entity over
|
|
which this MEP is configured."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 21 }
|
|
|
|
tmnxDot1agCfmMepEthTestThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..11840)
|
|
UNITS "bit errors"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthTestThreshold specifies when a
|
|
tmnxDot1agCfmMepEthTestComplete notification is sent. If
|
|
tmnxDot1agCfmMepEthTestThreshold is set to zero (0), a notification is
|
|
sent on the completion of any test for this MEP. Otherwise the
|
|
threshold must be exceeded and/or CRC failures must be detected to
|
|
send the notification."
|
|
DEFVAL { 1 }
|
|
::= { tmnxDot1agCfmMepEntry 22 }
|
|
|
|
tmnxDot1agCfmMepOWDTThreshold OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepOWDTThreshold specifies when a
|
|
tmnxDot1agCfmMepDMTestComplete notification is sent for a
|
|
one-way-delay test. If tmnxDot1agCfmMepOWDTThreshold is set to zero
|
|
(0), a notification is sent on the completion of any
|
|
one-way-delay-test for this MEP. Otherwise the threshold must be
|
|
exceeded to send the notification."
|
|
DEFVAL { 3 }
|
|
::= { tmnxDot1agCfmMepEntry 23 }
|
|
|
|
tmnxDot1agCfmMepFaultPropagation OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disabled (0),
|
|
useIfStatusTLV (1),
|
|
suspendCCM (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFaultPropagation specifies what action
|
|
should be taken by the MEP if a fault is detected in the service
|
|
containing the MEP. It also specifies if the MEP should propagate
|
|
a fault that it has detected into the service.
|
|
|
|
When this object is set to 'disabled (0)', no additional fault
|
|
propagation will occur. When this object is set to 'useIfStatusTLV
|
|
(1)', the MEP will send an interface status TLV in the next CCM
|
|
indicating fault when fault is detected, even if the MEP itself has
|
|
not detected a fault. When this object is set to 'suspendCCM (2)',
|
|
faults will be propagated by stopping the regular CCM transmissions
|
|
entirely. Once the fault is cleared, the regular CCM transmissions
|
|
will resume. Additionally, when the value of
|
|
tmnxDot1agCfmMepFaultPropagation is different than 'disabled (0)', a
|
|
defect detected by the MEP will be propagated into the service."
|
|
DEFVAL { disabled }
|
|
::= { tmnxDot1agCfmMepEntry 24 }
|
|
|
|
tmnxDot1agCfmMepFacilityIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndexOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFacilityIfIndex specifies, along with
|
|
tmnxDot1agCfmMepFacilityVlanId and tmnxDot1agCfmMepFacilityType, the
|
|
port or interface associated with this MEP.
|
|
|
|
The tmnxDot1agCfmMepFacilityIfIndex is applicable to facility MEPs
|
|
only, and MUST be set to zero (0) when dot1agCfmMepIfIndex,
|
|
dot1agCfmMepPrimaryVid, tmnxDot1agCfmMepSdpId, tmnxDot1agCfmMepVcId,
|
|
or tmnxDot1agCfmMepSvcId is non-zero. When this object is applicable
|
|
(non-zero), the above objects MUST be set to zero (0).
|
|
|
|
Once set, this object can not be modified."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 25 }
|
|
|
|
tmnxDot1agCfmMepFacilityVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrNone
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFacilityVlanId specifies, along with
|
|
tmnxDot1agCfmMepFacilityIfIndex and tmnxDot1agCfmMepFacilityType, the
|
|
encapsulation value of the port or interface associated with this MEP.
|
|
|
|
The tmnxDot1agCfmMepFacilityVlanId is applicable to facility MEPs
|
|
only, and MUST be set to zero (0) when dot1agCfmMepIfIndex,
|
|
dot1agCfmMepPrimaryVid, tmnxDot1agCfmMepSdpId, tmnxDot1agCfmMepVcId,
|
|
or tmnxDot1agCfmMepSvcId is non-zero. When this object is applicable
|
|
(non-zero), the above objects MUST be set to zero (0).
|
|
|
|
Once set, this object can not be modified."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 26 }
|
|
|
|
tmnxDot1agCfmMepFacilityType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
nonFacilityType (0),
|
|
port (1),
|
|
interface (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFacilityType specifies, along with
|
|
tmnxDot1agCfmMepFacilityIfIndex and tmnxDot1agCfmMepFacilityVlanId,
|
|
whether the port or interface is associated with this MEP.
|
|
|
|
The tmnxDot1agCfmMepFacilityType is applicable to facility MEPs only,
|
|
and MUST be set to 'nonFacilityType (0)' when dot1agCfmMepIfIndex,
|
|
dot1agCfmMepPrimaryVid, tmnxDot1agCfmMepSdpId, tmnxDot1agCfmMepVcId,
|
|
or tmnxDot1agCfmMepSvcId is non-zero. When this object is applicable
|
|
(non-zero), the above objects MUST be set to zero (0).
|
|
|
|
Once set, this object can not be modified."
|
|
DEFVAL { nonFacilityType }
|
|
::= { tmnxDot1agCfmMepEntry 27 }
|
|
|
|
tmnxDot1agCfmMepFcltyFaultNotify OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFcltyFaultNotify specifies whether or not
|
|
a fault detected on this Facility MEP will notify the port or facility
|
|
tunnel associated to this MEP.
|
|
|
|
This object pertains to Facility MEPs only. Attempting to change this
|
|
object away from its default for a non-facility MEP will result in an
|
|
'inconsistentValue' error."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 28 }
|
|
|
|
tmnxDot1agCfmMepDescription OBJECT-TYPE
|
|
SYNTAX TItemDescription
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepDescription specifies a user supplied
|
|
detailed description for this ETH-CFM MEP."
|
|
DEFVAL { "" }
|
|
::= { tmnxDot1agCfmMepEntry 29 }
|
|
|
|
tmnxDot1agCfmMepMcLagInactive OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
notApplicable (0),
|
|
standby (1),
|
|
active (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepMcLagInactive indicates whether or not the
|
|
MEP is inactive, 'standby (2)', due to the MC-LAG standby state. The
|
|
value of tmnxDot1agCfmMcLagStdbyInactive must be set to 'true (1)' for
|
|
this object to have meaning and return anything other than
|
|
'notApplicable (0)'."
|
|
::= { tmnxDot1agCfmMepEntry 30 }
|
|
|
|
tmnxDot1agCfmMepCcmPaddingSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 3..1500)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCcmPaddingSize specifies the number of
|
|
additional octets inserted into the CCM PDU for the Data TLV padding.
|
|
If tmnxDot1agCfmMepCcmPaddingSize is set to zero (0), no Data TLV will
|
|
be added to the CCM PDUs."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 31 }
|
|
|
|
tmnxDot1agCfmMepCcmIgnoreTLVs OBJECT-TYPE
|
|
SYNTAX BITS {
|
|
interfaceStatus (0),
|
|
portStatus (1)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCcmIgnoreTLVs specifies the set of TLVs
|
|
that are received in a CCM PDU for the Remote MEP state machine of the
|
|
MEP that will be validated for format correctness but their values
|
|
will be ignored and marked 'Absent' by ETH-CFM."
|
|
DEFVAL { {} }
|
|
::= { tmnxDot1agCfmMepEntry 32 }
|
|
|
|
tmnxDot1agCfmMepCsfEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCsfEnable specifies whether received CSF
|
|
(Client Signal Fault) frames are processed by the Maintenance Entity
|
|
Group (MEG)."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 33 }
|
|
|
|
tmnxDot1agCfmMepCsfRxMultiplier OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 20..300)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCsfRxMultiplier specifies the receive
|
|
period multiplier used for timing out CSF, in increments of 5.
|
|
|
|
To calculate the timeout period of CSF frames the following formula is
|
|
used:
|
|
|
|
(CSF-rx-interval X multiplier) / 10
|
|
|
|
The default multiplier, therefore, is 3.5 times the interval."
|
|
DEFVAL { 35 }
|
|
::= { tmnxDot1agCfmMepEntry 34 }
|
|
|
|
tmnxDot1agCfmMepCsfRxState OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
los (0),
|
|
ais (1),
|
|
rdi (2),
|
|
dci (3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCsfRxState indicates the state of the
|
|
received CSF frames for the MEP.
|
|
The values are:
|
|
los (0) - Client Loss of Signal
|
|
ais (1) - Client Forward Defect Indication
|
|
rdi (2) - Client Reverse Defect Indication
|
|
dci (3) - Client Defect Clear Indication"
|
|
DEFVAL { dci }
|
|
::= { tmnxDot1agCfmMepEntry 35 }
|
|
|
|
tmnxDot1agCfmMepCsfRxInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1 | 60)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCsfRxInterval indicates the CSF Interval
|
|
received in the most recent CSF frame."
|
|
DEFVAL { 1 }
|
|
::= { tmnxDot1agCfmMepEntry 36 }
|
|
|
|
tmnxDot1agCfmMepCsfRxCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCsfRxCount indicates the number of CSF
|
|
frames received on the MEP since the time CSF was enabled."
|
|
::= { tmnxDot1agCfmMepEntry 37 }
|
|
|
|
tmnxDot1agCfmMepEthAisTxFail OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthAisTxFail indicates the number of AIS
|
|
frames the MEP failed to transmit due to resource limitations."
|
|
::= { tmnxDot1agCfmMepEntry 38 }
|
|
|
|
tmnxDot1agCfmMepTxLbmTimeout OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..10)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTxLbmTimeout specifies the duration, in
|
|
seconds, before a loopback PDU sent by the node is considered to be
|
|
timed out."
|
|
DEFVAL { 5 }
|
|
::= { tmnxDot1agCfmMepEntry 39 }
|
|
|
|
tmnxDot1agCfmMepTxLbmInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 1..600)
|
|
UNITS "deciseconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTxLbmInterval specifies the duration,
|
|
in deciseconds, between loopback PDU transmissions. A value of zero
|
|
is only valid if there are 5 or fewer loopbacks in the test (as defined
|
|
by dot1agCfmMepTransmitLbmMessages)."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 40 }
|
|
|
|
tmnxDot1agCfmMepLbmPaddingSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 3..9778)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepLbmPaddingSize specifies the number of
|
|
additional octets inserted into the LBM PDU for the Data TLV padding.
|
|
If tmnxDot1agCfmMepLbmPaddingSize is set to zero (0), no Data TLV will
|
|
be added to the LBM PDUs. Note that setting this value is mutually
|
|
exclusive with setting dot1agCfmMepTransmitLbmDataTlv."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 41 }
|
|
|
|
tmnxDot1agCfmMepIfSupportEnable OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepIfSupportEnable specifies whether or not
|
|
the MEP will generate AIS PDUs when the endpoint associated to this
|
|
MEP is down regardless of CCM failures."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 42 }
|
|
|
|
tmnxDot1agCfmMepAisLowPrioDef OBJECT-TYPE
|
|
SYNTAX Dot1agCfmLowestAlarmPri
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepAisLowPrioDef specifies the lowest
|
|
priority defect that is allowed to generate an AIS frame.
|
|
|
|
When this object is 'allDef (1)', AIS frame generation will be
|
|
triggered for any defect in the CCM state machine.
|
|
|
|
When this object is 'macRemErrXcon (2)', AIS frame generation will be
|
|
triggered for defMACstatus defect and any defect higher than
|
|
defMACstatus."
|
|
DEFVAL { allDef }
|
|
::= { tmnxDot1agCfmMepEntry 43 }
|
|
|
|
tmnxDot1agCfmMepCollectLmmStats OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCollectLmmStats specifies whether or not
|
|
to compute the Y.1731 Ethernet Loss Measurement (ETH-LM) RxFCl and
|
|
TxFCl service frame counters for the specified MEP. Note that when
|
|
tmnxDot1agCfmMepCollectLmmStats is set to 'true', all data traffic
|
|
regardless of forwarding class level, both in and out of profile, will
|
|
be aggregated to a single stat counter.
|
|
|
|
Configuration of tmnxDot1agCfmMepCollectLmmStats is mutually exclusive
|
|
with the forwarding class level aware objects
|
|
tmnxDot1agCfmMepCollLmmFcSts and tmnxDot1agCfmMepCollLmmFcStsInP.
|
|
|
|
The RxFCl and TxFCl counters are used by ETH-LM tests. An ETH-LM test
|
|
is created using TIMETRA-OAM-PM-MIB::tmnxOamPmCfgLossLmmRowStatus."
|
|
REFERENCE
|
|
"ITU-T G.8013/Y.1731, 'OAM functions and mechanisms for Ethernet based
|
|
networks', 11/2013, Section 8.1 'Frame loss measurement (ETH-LM)'."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 44 }
|
|
|
|
tmnxDot1agCfmMepCreationOrigin OBJECT-TYPE
|
|
SYNTAX TmnxCreateOrigin
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCreationOrigin indicates the mechanism
|
|
which created this entry."
|
|
::= { tmnxDot1agCfmMepEntry 45 }
|
|
|
|
tmnxDot1agCfmMepEthTestTargMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthTestTargMepId specifies the
|
|
Maintenance association End Point Identifier (MepId) of another MEP in
|
|
the same Maintenance Association that the Eth-Test frames will be sent
|
|
to. If the tmnxDot1agCfmMepEthTestTargMepId is set then a local lookup
|
|
for the target MEP destination MAC address will be performed when the
|
|
test is started. Note that a valid target destination MAC address must
|
|
be found for proper execution of the Eth test if the
|
|
tmnxDot1agCfmMepEthTestTargMepId is being used as the input for the
|
|
test. The tmnxDot1agCfmMepEthTestTargMepId cannot be set if the
|
|
tmnxDot1agCfmMepEthTestMacAddr is set to a non-zero value.
|
|
|
|
Setting this object will trigger the test frame to be sent. Once the
|
|
test is complete, the object will revert to the default value,
|
|
indicating that another test is possible."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 46 }
|
|
|
|
tmnxDot1agCfmMepEthTestLstDstMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthTestLstDstMac indicates the
|
|
destination MAC address used in the most recent Eth-Test. If there
|
|
is no information about a previous test run, or if the test was not
|
|
able to be initiated properly, tmnxDot1agCfmMepEthTestLstDstMac will
|
|
have a value of all zeros. If the Eth-Test was initiated properly,
|
|
then the unicast MAC address that was used as the destination for the
|
|
most recent test PDU will be stored in
|
|
tmnxDot1agCfmMepEthTestLstDstMac."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepEntry 47 }
|
|
|
|
tmnxDot1agCfmMepOWDTTargetMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepOWDTTargetMepId specifies the Maintenance
|
|
association End Point Identifier (MepId) of another MEP in the same
|
|
Maintenance Association that the One-Way-Delay Test frames will be
|
|
sent to. If the tmnxDot1agCfmMepOWDTTargetMepId is set then a local
|
|
lookup for the target MEP destination MAC address will be performed
|
|
when the test is started. Note that a valid target destination MAC
|
|
address must be found for proper execution of the one-way-delay-test
|
|
if the tmnxDot1agCfmMepOWDTTargetMepId is being used as the input for
|
|
the test. The tmnxDot1agCfmMepOWDTTargetMepId cannot be set if the
|
|
tmnxDot1agCfmMepOWDTMacAddress is set to a non-zero value.
|
|
|
|
Setting this object will trigger the test frame to be sent. Once the
|
|
test is complete, the object will revert to the default value,
|
|
indicating that another test is possible."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 48 }
|
|
|
|
tmnxDot1agCfmMepOWDTLstDstMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepOWDTLstDstMac indicates the
|
|
destination MAC addressed used in the most recent One-Way-Delay Test.
|
|
If there is no information about a previous test run, or if the test
|
|
was not able to be initiated properly, tmnxDot1agCfmMepOWDTLstDstMac
|
|
will have a value of all zeros. If the One-Way-Delay Test was
|
|
initiated properly, then the unicast MAC address that was used as the
|
|
destination for the most recent test PDU will be stored in
|
|
tmnxDot1agCfmMepOWDTLstDstMac."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepEntry 49 }
|
|
|
|
tmnxDot1agCfmMepTWDTTargetMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTWDTTargetMepId specifies the Maintenance
|
|
association End Point Identifier (MepId) of another MEP in the same
|
|
Maintenance Association that the Two-Way-Delay Test frames will be
|
|
sent to. If the tmnxDot1agCfmMepTWDTTargetMepId is set then a local
|
|
lookup for the target MEP destination MAC address will be performed
|
|
when the test is started. Note that a valid target destination MAC
|
|
address must be found for proper execution of the two-way-delay-test
|
|
if the tmnxDot1agCfmMepTWDTTargetMepId is being used as the input for
|
|
the test. The tmnxDot1agCfmMepTWDTTargetMepId cannot be set if the
|
|
tmnxDot1agCfmMepTWDTMacAddress is set to a non-zero value.
|
|
|
|
Setting this object will trigger the test frame to be sent. Once the
|
|
test is complete, the object will revert to the default value,
|
|
indicating that another test is possible."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 50 }
|
|
|
|
tmnxDot1agCfmMepTWDTLstDstMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTWDTLstDstMac indicates the
|
|
destination MAC addressed used in the most recent Two-Way-Delay Test.
|
|
If there is no information about a previous test run, or if the test
|
|
was not able to be initiated properly, tmnxDot1agCfmMepTWDTLstDstMac
|
|
will have a value of all zeros. If the Two-Way-Delay Test was
|
|
initiated properly, then the unicast MAC address that was used as the
|
|
destination for the most recent test PDU will be stored in
|
|
tmnxDot1agCfmMepTWDTLstDstMac."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepEntry 51 }
|
|
|
|
tmnxDot1agCfmMepCollLmmFcSts OBJECT-TYPE
|
|
SYNTAX TFCSet
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCollLmmFcSts specifies which forwarding
|
|
class levels (in and out of profile combined) have enabled the
|
|
computation for Y.1731 Ethernet Loss Measurement (ETH-LM) RxFCl and
|
|
TxFCl service frame counters for the specified MEP. If the bit
|
|
corresponding to a forwarding class level is set, then a unique
|
|
counter will be used to track all the combined in and out of profile
|
|
traffic associated with that forwarding class.
|
|
|
|
Note that no tmnxDot1agCfmMepCollLmmFcSts bits can be set if
|
|
tmnxDot1agCfmMepCollectLmmStats is set to 'true' as the two are
|
|
mutually exclusive.
|
|
|
|
The RxFCl and TxFCl counters are used by ETH-LM tests. An ETH-LM test
|
|
is created using TIMETRA-OAM-PM-MIB::tmnxOamPmCfgLossLmmRowStatus."
|
|
REFERENCE
|
|
"ITU-T G.8013/Y.1731, 'OAM functions and mechanisms for Ethernet based
|
|
networks', 11/2013, Section 8.1 'Frame loss measurement (ETH-LM)'."
|
|
DEFVAL { {} }
|
|
::= { tmnxDot1agCfmMepEntry 52 }
|
|
|
|
tmnxDot1agCfmMepCollLmmFcStsInP OBJECT-TYPE
|
|
SYNTAX TFCSet
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCollLmmFcStsInP specifies which
|
|
forwarding class levels (in profile only) have enabled the computation
|
|
for Y.1731 Ethernet Loss Measurement (ETH-LM) RxFCl and TxFCl service
|
|
frame counters for the specified MEP. If the bit corresponding to a
|
|
forwarding class level is set, then a unique counter will be used to
|
|
track only all the in profile data traffic that is associated with
|
|
that forwarding class.
|
|
|
|
Note that no tmnxDot1agCfmMepCollLmmFcStsInP bits can be set if
|
|
tmnxDot1agCfmMepCollectLmmStats is set to 'true' as the two are
|
|
mutually exclusive.
|
|
|
|
The RxFCl and TxFCl counters are used by ETH-LM tests. An ETH-LM test
|
|
is created using TIMETRA-OAM-PM-MIB::tmnxOamPmCfgLossLmmRowStatus."
|
|
REFERENCE
|
|
"ITU-T G.8013/Y.1731, 'OAM functions and mechanisms for Ethernet based
|
|
networks', 11/2013, Section 8.1 'Frame loss measurement (ETH-LM)'."
|
|
DEFVAL { {} }
|
|
::= { tmnxDot1agCfmMepEntry 53 }
|
|
|
|
tmnxDot1agCfmMepTxEthVsmGrace OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTxEthVsmGrace specifies whether or not
|
|
Vendor Specific Message (VSM) grace period notifications will be sent
|
|
to the ETH-CFM remote MEP peers of this local MEP. The value 'true
|
|
(1)' enables grace period notifications, and the value 'false (2)'
|
|
suppresses the notifications.
|
|
|
|
During an outage, the modification of this object from 'true (1)' to
|
|
'false (2)' will cause an immediate clear of all grace period
|
|
notifications, after which no further notifications will be sent. A
|
|
modification of this object from 'false (2)' to 'true (1)' will not
|
|
enable the transmission of VSM grace period for any outages currently
|
|
in progress but will take effect for subsequent outages.
|
|
|
|
Note that this value is mutually exclusive to tmnxDot1agCfmMepTxEthEd,
|
|
and only one of the two can be enabled at any time."
|
|
DEFVAL { true }
|
|
::= { tmnxDot1agCfmMepEntry 54 }
|
|
|
|
tmnxDot1agCfmMepRxEthVsmGrace OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepRxEthVsmGrace specifies whether or not
|
|
VSM grace period notifications that are received on the local MEP
|
|
will be processed. The value 'true (1)' enables grace period
|
|
notification processing, and the value 'false (2)' disables
|
|
processing and causes any received VSM grace period notifications to
|
|
be ignored."
|
|
DEFVAL { true }
|
|
::= { tmnxDot1agCfmMepEntry 55 }
|
|
|
|
tmnxDot1agCfmMepTxEthEd OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTxEthEd specifies whether or not Ethernet
|
|
Expect Defect (ETH-ED) PDUs will be sent to the ETH-CFM remote MEP
|
|
peers of this local MEP. The value 'true (1)' enables ETH-ED PDU
|
|
transmission, and the value 'false (2)' suppresses transmissions.
|
|
|
|
During an outage, the modification of this object from 'true (1)' to
|
|
'false (2)' will cause an immediate clear of the ETH-ED PDU
|
|
transmission state, after which no further notifications will be sent.
|
|
A modification of this object from 'false (2)' to 'true (1)' will not
|
|
enable the transmission of ETH-ED for any outages currently in
|
|
progress, but will take effect for subsequent outages.
|
|
|
|
Note that this value is mutually exclusive to
|
|
tmnxDot1agCfmMepTxEthVsmGrace, and only one of the two can be enabled
|
|
at any time."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 56 }
|
|
|
|
tmnxDot1agCfmMepRxEthEd OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepRxEthEd specifies whether or not ETH-ED
|
|
PDUs that are received on the local MEP will be processed. The value
|
|
'true (1)' enables ETH-ED PDU processing, and the value 'false (2)'
|
|
disables processing and causes received MCC-ED notifications to be
|
|
ignored."
|
|
DEFVAL { true }
|
|
::= { tmnxDot1agCfmMepEntry 57 }
|
|
|
|
tmnxDot1agCfmMepEthEdMaxDurRx OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..86400)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthEdMaxDurRx specifies the maximum
|
|
Expected Duration value, in seconds, that will be used to track a peer
|
|
MEP outage. This value limits the size of the received ETH-ED expected
|
|
defect window to the lesser of the received value from the peer, or
|
|
the value of tmnxDot1agCfmMepEthEdMaxDurRx. A value of zero (0)
|
|
specifies that the received defect window advertised by the peer will
|
|
be used."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepEntry 58 }
|
|
|
|
tmnxDot1agCfmMepEthEdPriority OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthEdPriority specifies the priority
|
|
value for ETH-ED PDUs transmitted by the MEP.
|
|
|
|
If this object has the value '-1', the priority of this entry is
|
|
deferred to the dot1agCfmMepCcmLtmPriority associated with this MEP."
|
|
DEFVAL { -1 }
|
|
::= { tmnxDot1agCfmMepEntry 59 }
|
|
|
|
tmnxDot1agCfmMepLbmSvcActResp OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepLbmSvcActResp specifies whether or not
|
|
the MEP is capable of processing service activation streams
|
|
encapsulated in the ETH-CFM request Loopback Message (LBM).
|
|
|
|
When the value of this object is 'true (1)', additional resources will
|
|
be allocated to allow the MEP to respond to high bandwidth requests,
|
|
which are typically service activation requests, encapsulated in the
|
|
ETH-LBM format. While this object is 'true (1)' the MEP will not
|
|
validate any type-length-value (TLV)s and will not increment or
|
|
compute any loopback statistics.
|
|
|
|
When this object is 'false (2)', the MEP LBMs are reverted to standard
|
|
processing."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 60 }
|
|
|
|
tmnxDot1agCfmMepEthBnReceive OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnReceive specifies whether or not the
|
|
reception and processing of Eth-BN (Ethernet Bandwidth Notification)
|
|
PDUs is enabled.
|
|
|
|
The value 'true (1)' specifies that the reception and processing is
|
|
enabled."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 61 }
|
|
|
|
tmnxDot1agCfmMepEthBnRxUpdPacing OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..600)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnRxUpdPacing specifies the pacing of
|
|
the messages from the Eth-CFM subsystem to the QoS subsystem. The
|
|
updates will be held by the Eth-CFM subsystem, but the sending of the
|
|
most recent update will be held until the expiration of the pacing
|
|
timer."
|
|
DEFVAL { 5 }
|
|
::= { tmnxDot1agCfmMepEntry 62 }
|
|
|
|
tmnxDot1agCfmMepInstallMep OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepInstallMep specifies whether or not the
|
|
MEP is installed in the forwarding plane and runs any of the Eth-CFM
|
|
State Machines.
|
|
|
|
When the value of this object is set to 'true (1)', the administrative
|
|
state of the MEP can be enabled.
|
|
|
|
When the value of this object is 'false (2)', the MEP will not
|
|
terminate ETH-CFM PDUs at any level in any direction. In addition, the
|
|
MEPs administative state must also be disabled.
|
|
|
|
The MEP must be administratively down in order to change the value of
|
|
this object."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepEntry 63 }
|
|
|
|
tmnxDot1agCfmMepEthTestRsltTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepEthTestRsltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepEthTestRsltTable indicates the results of all
|
|
eth-tests indexed by the originating MAC addresses.
|
|
|
|
This table is not persistent over reboots of the chassis."
|
|
::= { tmnxDot1agCfmMep 2 }
|
|
|
|
tmnxDot1agCfmMepEthTestRsltEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepEthTestRsltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MEG result table."
|
|
INDEX {
|
|
dot1agCfmMdIndex,
|
|
dot1agCfmMaIndex,
|
|
dot1agCfmMepIdentifier,
|
|
tmnxDot1agCfmMepSrcMacAddress
|
|
}
|
|
::= { tmnxDot1agCfmMepEthTestRsltTable 1 }
|
|
|
|
TmnxDot1agCfmMepEthTestRsltEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepSrcMacAddress MacAddress,
|
|
tmnxDot1agCfmMepFrameCount Counter32,
|
|
tmnxDot1agCfmMepByteCount Counter32,
|
|
tmnxDot1agCfmMepFailedBits Counter32,
|
|
tmnxDot1agCfmMepCrcFailures Counter32,
|
|
tmnxDot1agCfmMepCurrByteCount Gauge32,
|
|
tmnxDot1agCfmMepCurrFailedBits Gauge32,
|
|
tmnxDot1agCfmMepCurrCrcFailures TruthValue
|
|
}
|
|
|
|
tmnxDot1agCfmMepSrcMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSrcMacAddress indicates the MAC address
|
|
of the issuer of the eth-test."
|
|
::= { tmnxDot1agCfmMepEthTestRsltEntry 1 }
|
|
|
|
tmnxDot1agCfmMepFrameCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFrameCount indicates the number of frames
|
|
received from the issuer of the eth-test."
|
|
::= { tmnxDot1agCfmMepEthTestRsltEntry 2 }
|
|
|
|
tmnxDot1agCfmMepByteCount OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepByteCount indicates the number of bytes
|
|
received from the issuer of the eth-test."
|
|
::= { tmnxDot1agCfmMepEthTestRsltEntry 3 }
|
|
|
|
tmnxDot1agCfmMepFailedBits OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFailedBits indicates the accumulated
|
|
number of bits that did not match the test pattern in all received
|
|
Eth-Tst frames since tmnxDot1agCfmMepEthTestEnable is configured from
|
|
'false' to 'true'."
|
|
::= { tmnxDot1agCfmMepEthTestRsltEntry 4 }
|
|
|
|
tmnxDot1agCfmMepCrcFailures OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCrcFailures indicates the accumulated
|
|
number of CRC checksum failures."
|
|
::= { tmnxDot1agCfmMepEthTestRsltEntry 5 }
|
|
|
|
tmnxDot1agCfmMepCurrByteCount OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCurrByteCount indicates the number of
|
|
bytes contained in the most recently received Eth-Tst frame Test TLV."
|
|
::= { tmnxDot1agCfmMepEthTestRsltEntry 6 }
|
|
|
|
tmnxDot1agCfmMepCurrFailedBits OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCurrFailedBits indicates the number of
|
|
bits that did not match the test pattern in the most recently received
|
|
Eth-Tst frame."
|
|
::= { tmnxDot1agCfmMepEthTestRsltEntry 7 }
|
|
|
|
tmnxDot1agCfmMepCurrCrcFailures OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCurrCrcFailures indicates that CRC errors
|
|
were detected in the most recently received Eth-Tst frame."
|
|
::= { tmnxDot1agCfmMepEthTestRsltEntry 8 }
|
|
|
|
tmnxDot1agCfmMepDelayRsltTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepDelayRsltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepDelayRsltTable indicates the results of all the
|
|
One-Way/Two-Way Delay Tests from the originating MAC addresses.
|
|
|
|
This table is not persistent over reboots of the chassis."
|
|
::= { tmnxDot1agCfmMep 3 }
|
|
|
|
tmnxDot1agCfmMepDelayRsltEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepDelayRsltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MEG result table."
|
|
INDEX {
|
|
dot1agCfmMdIndex,
|
|
dot1agCfmMaIndex,
|
|
dot1agCfmMepIdentifier,
|
|
tmnxDot1agCfmMepDelaySrcMacAddr,
|
|
tmnxDot1agCfmMepDelayTestType
|
|
}
|
|
::= { tmnxDot1agCfmMepDelayRsltTable 1 }
|
|
|
|
TmnxDot1agCfmMepDelayRsltEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepDelaySrcMacAddr MacAddress,
|
|
tmnxDot1agCfmMepDelayTestType INTEGER,
|
|
tmnxDot1agCfmMepDelayTestDelay Integer32,
|
|
tmnxDot1agCfmMepDelayVariation Unsigned32
|
|
}
|
|
|
|
tmnxDot1agCfmMepDelaySrcMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepDelaySrcMacAddr indicates the source MAC
|
|
address of the issuer of the test."
|
|
::= { tmnxDot1agCfmMepDelayRsltEntry 1 }
|
|
|
|
tmnxDot1agCfmMepDelayTestType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oneWayTest (1),
|
|
twoWayTest (2)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepDelayTestType indicates the type of test
|
|
this row details."
|
|
::= { tmnxDot1agCfmMepDelayRsltEntry 2 }
|
|
|
|
tmnxDot1agCfmMepDelayTestDelay OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepDelayTestDelay indicates the amount of
|
|
time, measured in microseconds, from when the test-frame was
|
|
transmitted to the time it was received minus the local processing
|
|
time taken by the remote system."
|
|
::= { tmnxDot1agCfmMepDelayRsltEntry 3 }
|
|
|
|
tmnxDot1agCfmMepDelayVariation OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "microseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepDelayVariation indicates the amount of
|
|
time delay variation, measured in microseconds, from the two most
|
|
recent time delay measurements"
|
|
::= { tmnxDot1agCfmMepDelayRsltEntry 4 }
|
|
|
|
tmnxDot1agCfmMepSlmTWTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepSlmTWTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepSlmTWTestTable consists of the MEP configuration for
|
|
issuing individual Synthetic Loss Measurement tests."
|
|
REFERENCE
|
|
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
|
|
::= { tmnxDot1agCfmMep 4 }
|
|
|
|
tmnxDot1agCfmMepSlmTWTestEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepSlmTWTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepSlmTWTestEntry contains the configuration for
|
|
generating Synthetic Loss Measurement (SLM) Tests for a particular
|
|
MEP. A row exists for each row in the dot1agCfmMepTable, and is
|
|
destroyed automatically with the removal of a row in the
|
|
dot1agCfmMepTable.
|
|
|
|
Results from a two-way SLM test are reported in
|
|
tmnxDot1agCfmMepSlmTestRsltTable with the tmnxDot1agCfmMepSlmTestType
|
|
set to 'twoWayTest (2)'."
|
|
AUGMENTS { dot1agCfmMepEntry }
|
|
::= { tmnxDot1agCfmMepSlmTWTestTable 1 }
|
|
|
|
TmnxDot1agCfmMepSlmTWTestEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepSlmTWTestStatus TmnxEnabledDisabled,
|
|
tmnxDot1agCfmMepSlmTWTestId Unsigned32,
|
|
tmnxDot1agCfmMepSlmTWMacAddress MacAddress,
|
|
tmnxDot1agCfmMepSlmTWPriority Unsigned32,
|
|
tmnxDot1agCfmMepSlmTWInterval Unsigned32,
|
|
tmnxDot1agCfmMepSlmTWTimeout Unsigned32,
|
|
tmnxDot1agCfmMepSlmTWDataSize Unsigned32,
|
|
tmnxDot1agCfmMepSlmTWSendCount Unsigned32,
|
|
tmnxDot1agCfmMepSlmTWIntrvlUnits INTEGER,
|
|
tmnxDot1agCfmMepSlmTWTargetMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmMepSlmTWLstDstMac MacAddress
|
|
}
|
|
|
|
tmnxDot1agCfmMepSlmTWTestStatus OBJECT-TYPE
|
|
SYNTAX TmnxEnabledDisabled
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWTestStatus specifies the operational
|
|
state of the two-way Synthetic Loss Measurement (SLM) test.
|
|
|
|
To issue a two-way SLM test the user must issue an SNMP SET on this
|
|
object with a value 'enabled (1)'. To abort the two-way SLM test issue
|
|
an SNMP SET on this object with the value 'disabled (2)'.
|
|
|
|
A read on this object represents the current state of the two-way SLM
|
|
test:
|
|
enabled (1) - The test is actively running, and attempts at
|
|
modifying any two-way SLM object will be rejected
|
|
disabled (2) - The test is not running.
|
|
|
|
Once the test is complete this object will revert to the default value
|
|
'disabled (2)'."
|
|
DEFVAL { disabled }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 1 }
|
|
|
|
tmnxDot1agCfmMepSlmTWTestId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWTestId indicates the test identifier
|
|
used to initiate the two-way Synthetic Loss Measurement (SLM) test."
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 2 }
|
|
|
|
tmnxDot1agCfmMepSlmTWMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWMacAddress specifies the MAC address
|
|
used as a target for the two-way Synthetic Loss Measurement (SLM)
|
|
test.
|
|
|
|
This object MUST be set to a valid MAC Address for proper execution of
|
|
the two-way SLM test if tmnxDot1agCfmMepSlmTWTargetMepId is set to
|
|
zero (0)."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 3 }
|
|
|
|
tmnxDot1agCfmMepSlmTWPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWPriority specifies the priority used
|
|
in the generated test frame for the two-way Synthetic Loss Measurement
|
|
(SLM) test."
|
|
DEFVAL { 7 }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 4 }
|
|
|
|
tmnxDot1agCfmMepSlmTWInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..90)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWInterval, in conjunction with
|
|
tmnxDot1agCfmMepSlmTWIntrvlUnits, specifies the interval between
|
|
Synthetic Loss Measurement (SLM) messages sent by the two-way SLM
|
|
test. For example, if tmnxDot1agCfmMepSlmTWInterval has the value 90,
|
|
and tmnxDot1agCfmMepSlmTWIntrvlUnits has the value 'centiseconds(2)',
|
|
the interval between SLM messages is 0.9 seconds.
|
|
|
|
The tmnxDot1agCfmMepSlmTWInterval and tmnxDot1agCfmMepSlmTWIntrvlUnits
|
|
pair provide support for the following intervals:
|
|
0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, 0.9 seconds;
|
|
1, 2, 3, 4, 5, 6, 7, 8, 9, 10 seconds."
|
|
DEFVAL { 5 }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 5 }
|
|
|
|
tmnxDot1agCfmMepSlmTWTimeout OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..10)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWTimeout specifies the timeout value,
|
|
in seconds, to wait for a Synthetic Loss Measurement (SLM) message to
|
|
reply for the two-way SLM test. Upon expiration of the timeout period,
|
|
the agent assumes that the message response will not be received. Any
|
|
response received after the timeout period has expired is silently
|
|
discarded."
|
|
DEFVAL { 5 }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 6 }
|
|
|
|
tmnxDot1agCfmMepSlmTWDataSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1500)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWDataSize specifies the data size, in
|
|
bytes, contained in the padding TLV for the two-way Synthetic Loss
|
|
Measurement (SLM) test. A value of zero (0) specifies that no padding
|
|
TLV is inserted in the SLM packet. Any non-zero value will increase
|
|
the packet size by the specified data size plus 3 bytes for the TLV
|
|
header."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 7 }
|
|
|
|
tmnxDot1agCfmMepSlmTWSendCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..1000)
|
|
UNITS "packets"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWSendCount specifies the number of
|
|
Synthetic Loss Measurement (SLM) packets to send during the two-way
|
|
SLM test."
|
|
DEFVAL { 1 }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 8 }
|
|
|
|
tmnxDot1agCfmMepSlmTWIntrvlUnits OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
seconds (1),
|
|
centiseconds (2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWIntrvlUnits, in conjunction with
|
|
tmnxDot1agCfmMepSlmTWInterval, specifies the interval between Synthetic
|
|
Loss Measurement (SLM) messages sent by the two-way SLM test. For
|
|
example, if tmnxDot1agCfmMepSlmTWInterval has the value 90, and
|
|
tmnxDot1agCfmMepSlmTWIntrvlUnits has the value 'centiseconds(2)', the
|
|
interval between SLM messages is 0.9 seconds.
|
|
|
|
The intervals supported are shown in the tmnxDot1agCfmMepSlmTWInterval
|
|
DESCRIPTION clause."
|
|
DEFVAL { seconds }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 9 }
|
|
|
|
tmnxDot1agCfmMepSlmTWTargetMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWTargetMepId specifies the
|
|
Maintenance association End Point Identifier (MepId) of another MEP
|
|
in the same Maintenance Association that the Synthetic Loss
|
|
Measurement (SLM) messages should be directed to. If the
|
|
tmnxDot1agCfmMepSlmTWTargetMepId is set then a local lookup for the
|
|
target MEP destination MAC address will be performed when the test is
|
|
started. Note that a valid target destination MAC address must be
|
|
found for proper execution of the two-way SLM test if the
|
|
tmnxDot1agCfmMepSlmTWTargetMepId is being used as the input for the
|
|
test. The tmnxDot1agCfmMepSlmTWTargetMepId cannot be set if the
|
|
tmnxDot1agCfmMepSlmTWMacAddress is set to a non-zero value."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 10 }
|
|
|
|
tmnxDot1agCfmMepSlmTWLstDstMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTWLstDstMac indicates the
|
|
destination MAC addressed used in the most recent two-way SLM Test.
|
|
If there is no information about a previous test run, or if the test
|
|
was not able to be initiated properly, tmnxDot1agCfmMepSlmTWLstDstMac
|
|
will have a value of all zeros. If the two-way SLM Test was initiated
|
|
properly, then the unicast MAC address that was used as the
|
|
destination for the most recent test PDU will be stored in
|
|
tmnxDot1agCfmMepSlmTWLstDstMac."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepSlmTWTestEntry 11 }
|
|
|
|
tmnxDot1agCfmMepSlmOWTestTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepSlmOWTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepSlmOWTestTable consists of the MEP configuration for
|
|
issuing individual Synthetic Loss Measurement one-way tests."
|
|
REFERENCE
|
|
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
|
|
::= { tmnxDot1agCfmMep 5 }
|
|
|
|
tmnxDot1agCfmMepSlmOWTestEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepSlmOWTestEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepSlmOWTestEntry contains the configuration for
|
|
generating Synthetic Loss Measurement (SLM) Tests for a particular
|
|
MEP. A row exists for each row in the dot1agCfmMepTable, and is
|
|
destroyed automatically with the removal of a row in the
|
|
dot1agCfmMepTable.
|
|
|
|
Results from a one-way SLM test are reported in
|
|
tmnxDot1agCfmMepSlmTestRsltTable with tmnxDot1agCfmMepSlmTestType set
|
|
to 'oneWayTest (1)'."
|
|
AUGMENTS { dot1agCfmMepEntry }
|
|
::= { tmnxDot1agCfmMepSlmOWTestTable 1 }
|
|
|
|
TmnxDot1agCfmMepSlmOWTestEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepSlmOWTestStatus TmnxEnabledDisabled,
|
|
tmnxDot1agCfmMepSlmOWTestId Unsigned32,
|
|
tmnxDot1agCfmMepSlmOWMacAddress MacAddress,
|
|
tmnxDot1agCfmMepSlmOWPriority Unsigned32,
|
|
tmnxDot1agCfmMepSlmOWInterval Unsigned32,
|
|
tmnxDot1agCfmMepSlmOWDataSize Unsigned32,
|
|
tmnxDot1agCfmMepSlmOWSendCount Unsigned32,
|
|
tmnxDot1agCfmMepSlmOWTargetMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmMepSlmOWLstDstMac MacAddress
|
|
}
|
|
|
|
tmnxDot1agCfmMepSlmOWTestStatus OBJECT-TYPE
|
|
SYNTAX TmnxEnabledDisabled
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWTestStatus specifies the operational
|
|
state of the one-way Synthetic Loss Measurement (SLM) test.
|
|
|
|
To issue a one-way SLM test the user must issue an SNMP SET on this
|
|
object with a value 'enabled (1)'. To abort the one-way SLM test issue
|
|
an SNMP SET on this object with the value 'disabled (2)'.
|
|
|
|
A read on this object represents the current state of the one-way SLM
|
|
test:
|
|
enabled (1) - The test is actively running, and attempts at
|
|
modifying any one-way SLM object will be rejected
|
|
disabled (2) - The test is not running.
|
|
|
|
Once the test is complete this object will revert to the default value
|
|
'disabled (2)'."
|
|
DEFVAL { disabled }
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 1 }
|
|
|
|
tmnxDot1agCfmMepSlmOWTestId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWTestId indicates the test identifier
|
|
used to initiate the one-way Synthetic Loss Measurement (SLM) test."
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 2 }
|
|
|
|
tmnxDot1agCfmMepSlmOWMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWMacAddress specifies the MAC address
|
|
used as a target for the one-way Synthetic Loss Measurement (SLM)
|
|
Test.
|
|
|
|
This object MUST be set to a valid MAC Address for proper execution of
|
|
the one-way SLM test if tmnxDot1agCfmMepSlmOWTargetMepId is set to
|
|
zero (0)."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 3 }
|
|
|
|
tmnxDot1agCfmMepSlmOWPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWPriority specifies the priority used
|
|
in the generated test frame for the one-way Synthetic Loss Measurement
|
|
(SLM) test."
|
|
DEFVAL { 7 }
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 4 }
|
|
|
|
tmnxDot1agCfmMepSlmOWInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..10)
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWInterval specifies the delay, in
|
|
seconds, between Synthetic Loss Measurement (SLM) messages for the
|
|
one-way SLM test."
|
|
DEFVAL { 5 }
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 5 }
|
|
|
|
tmnxDot1agCfmMepSlmOWDataSize OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..1500)
|
|
UNITS "bytes"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWDataSize specifies the data size, in
|
|
bytes, contained in the padding TLV for the one-way Synthetic Loss
|
|
Measurement (SLM) test. A value of zero (0) specifies that no padding
|
|
TLV is inserted in the SLM packet. Any non-zero value will increase
|
|
the packet size by the specified data size plus 3 bytes for the TLV
|
|
header."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 6 }
|
|
|
|
tmnxDot1agCfmMepSlmOWSendCount OBJECT-TYPE
|
|
SYNTAX Unsigned32 (1..100)
|
|
UNITS "packets"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWSendCount specifies the number of
|
|
Synthetic Loss Measurement (SLM) packets to send consecutively during
|
|
the one-way SLM test."
|
|
DEFVAL { 1 }
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 7 }
|
|
|
|
tmnxDot1agCfmMepSlmOWTargetMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWTargetMepId specifies the
|
|
Maintenance association End Point Identifier (MepId) of another MEP
|
|
in the same Maintenance Association that the Synthetic Loss
|
|
Measurement (SLM) messages should be directed to. If the
|
|
tmnxDot1agCfmMepSlmOWTargetMepId is set then a local lookup for the
|
|
target MEP destination MAC address will be performed when the test is
|
|
started. Note that a valid target destination MAC address must be
|
|
found for proper execution of the one-way SLM test if the
|
|
tmnxDot1agCfmMepSlmOWTargetMepId is being used as the input for the
|
|
test. The tmnxDot1agCfmMepSlmOWTargetMepId cannot be set if the
|
|
tmnxDot1agCfmMepSlmOWMacAddress is set to a non-zero value."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 8 }
|
|
|
|
tmnxDot1agCfmMepSlmOWLstDstMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmOWLstDstMac indicates the
|
|
destination MAC addressed used in the most recent one-way SLM Test.
|
|
If there is no information about a previous test run, or if the test
|
|
was not able to be initiated properly, tmnxDot1agCfmMepSlmOWLstDstMac
|
|
will have a value of all zeros. If the one-way SLM Test was initiated
|
|
properly, then the unicast MAC address that was used as the
|
|
destination for the most recent test PDU will be stored in
|
|
tmnxDot1agCfmMepSlmOWLstDstMac."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmMepSlmOWTestEntry 9 }
|
|
|
|
tmnxDot1agCfmMepSlmTestRsltTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepSlmTestRsltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepSlmTestRsltTable consists of the results of manually
|
|
triggered Synthetic Loss Measurement tests."
|
|
::= { tmnxDot1agCfmMep 6 }
|
|
|
|
tmnxDot1agCfmMepSlmTestRsltEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepSlmTestRsltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepSlmTestRsltEntry contains the results of a manually
|
|
triggered Synthetic Loss Measurement (SLM) test for a particular MEP.
|
|
Rows are auto-generated by the system based on the issuing of a SLM
|
|
test."
|
|
INDEX {
|
|
dot1agCfmMdIndex,
|
|
dot1agCfmMaIndex,
|
|
dot1agCfmMepIdentifier,
|
|
tmnxDot1agCfmMepSlmTestType,
|
|
tmnxDot1agCfmMepSlmRemoteMacAddr
|
|
}
|
|
::= { tmnxDot1agCfmMepSlmTestRsltTable 1 }
|
|
|
|
TmnxDot1agCfmMepSlmTestRsltEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepSlmTestType INTEGER,
|
|
tmnxDot1agCfmMepSlmRemoteMacAddr MacAddress,
|
|
tmnxDot1agCfmMepSlmTestId Unsigned32,
|
|
tmnxDot1agCfmMepSlmRemoteMepId Dot1agCfmMepIdOrZero,
|
|
tmnxDot1agCfmMepSlmLastTxSeqF Unsigned32,
|
|
tmnxDot1agCfmMepSlmPacketIn Counter32,
|
|
tmnxDot1agCfmMepSlmPacketLossIn Integer32,
|
|
tmnxDot1agCfmMepSlmPacketLossOut Integer32,
|
|
tmnxDot1agCfmMepSlmPacketUnack Gauge32
|
|
}
|
|
|
|
tmnxDot1agCfmMepSlmTestType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
oneWayTest (1),
|
|
twoWayTest (2)
|
|
}
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTestType specifies whether the row for
|
|
this Synthetic Loss Measurement (SLM) test refers to a two-way SLM
|
|
test."
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 1 }
|
|
|
|
tmnxDot1agCfmMepSlmRemoteMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmRemoteMacAddr specifies the source MAC
|
|
address of the remote node involved in the test."
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 2 }
|
|
|
|
tmnxDot1agCfmMepSlmTestId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmTestId indicates the test identifier
|
|
that was used to initiate the Synthetic Loss Measurement (SLM) test."
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 3 }
|
|
|
|
tmnxDot1agCfmMepSlmRemoteMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepIdOrZero
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmRemoteMepId indicates the MEP
|
|
Identifier of the remote node involved in the test.
|
|
|
|
Zero indicates that the remote node did not provide a MEP Identifier.
|
|
For example, zero is returned if the local node timed out while
|
|
waiting for a probe response for each probe sent for the test."
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 4 }
|
|
|
|
tmnxDot1agCfmMepSlmLastTxSeqF OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmLastTxSeqF indicates the last received
|
|
sequence number on the local node, transmitted by the remote node."
|
|
REFERENCE
|
|
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 5 }
|
|
|
|
tmnxDot1agCfmMepSlmPacketIn OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmPacketIn indicates the number of
|
|
packets received during the execution of the test."
|
|
REFERENCE
|
|
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 6 }
|
|
|
|
tmnxDot1agCfmMepSlmPacketLossIn OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmPacketLossIn indicates the number of
|
|
packets transmitted from the remote node but not received on the local
|
|
node during the execution of the test."
|
|
REFERENCE
|
|
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 7 }
|
|
|
|
tmnxDot1agCfmMepSlmPacketLossOut OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmPacketLossOut indicates the number of
|
|
packets transmitted from the local node but not received on the remote
|
|
node during the execution of the test."
|
|
REFERENCE
|
|
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 8 }
|
|
|
|
tmnxDot1agCfmMepSlmPacketUnack OBJECT-TYPE
|
|
SYNTAX Gauge32
|
|
UNITS "packets"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepSlmPacketUnack indicates the number of
|
|
unacknowledged lost packets during the execution of the test."
|
|
REFERENCE
|
|
"ITU-T Y.1731 Ethernet Synthetic Frame Loss Measurement (ETH-SLM)"
|
|
::= { tmnxDot1agCfmMepSlmTestRsltEntry 9 }
|
|
|
|
tmnxDot1agCfmMepMcstLbmRsltTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepMcstLbmRsltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepMcstLbmRsltTable consists of the results of manually
|
|
triggered ETH-CFM loopback tests where the value of
|
|
dot1agCfmMepTransmitLbmDestMacAddress was set to the multicast MAC
|
|
address for the MEP.
|
|
|
|
Only one result set per MEP is retained."
|
|
::= { tmnxDot1agCfmMep 7 }
|
|
|
|
tmnxDot1agCfmMepMcstLbmRsltEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepMcstLbmRsltEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepMcstLbmRsltEntry contains an individual message
|
|
response to a manually triggered loopback test.
|
|
|
|
A row is auto-generated by the system upon receipt of a valid loopback
|
|
response that matches a multicast loopback test in progress."
|
|
INDEX {
|
|
dot1agCfmMdIndex,
|
|
dot1agCfmMaIndex,
|
|
dot1agCfmMepIdentifier,
|
|
tmnxDot1agCfmMepLbmRemoteMepMac,
|
|
tmnxDot1agCfmMepLbmSeqNumber,
|
|
tmnxDot1agCfmMepLbmRxIndex
|
|
}
|
|
::= { tmnxDot1agCfmMepMcstLbmRsltTable 1 }
|
|
|
|
TmnxDot1agCfmMepMcstLbmRsltEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepLbmRemoteMepMac MacAddress,
|
|
tmnxDot1agCfmMepLbmSeqNumber Unsigned32,
|
|
tmnxDot1agCfmMepLbmRxIndex Unsigned32
|
|
}
|
|
|
|
tmnxDot1agCfmMepLbmRemoteMepMac OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepLbmRemoteMepMac specifies the MAC address
|
|
of the remote MEP responding to the multicast loopback message."
|
|
::= { tmnxDot1agCfmMepMcstLbmRsltEntry 1 }
|
|
|
|
tmnxDot1agCfmMepLbmSeqNumber OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepLbmSeqNumber specifies the sequence
|
|
number contained within the reply message."
|
|
::= { tmnxDot1agCfmMepMcstLbmRsltEntry 2 }
|
|
|
|
tmnxDot1agCfmMepLbmRxIndex OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepLbmRxIndex indicates the order in which
|
|
the reply was received for the corresponding remote MAC address. It
|
|
is locally assigned and can be used to detect out of order responses."
|
|
::= { tmnxDot1agCfmMepMcstLbmRsltEntry 3 }
|
|
|
|
tmnxDot1agCfmMepDbTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepDbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepDbTable is an augmented table for the standard
|
|
IEEE8021-CFM table dot1agCfmMepDbTable."
|
|
::= { tmnxDot1agCfmMep 8 }
|
|
|
|
tmnxDot1agCfmMepDbEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepDbEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepDbEntry is an augmented conceptual row in the
|
|
dot1agCfmMepDbTable. Objects defined in this row extend the
|
|
functionality of the base row.
|
|
|
|
Creation and deletion of rows in this table is managed through the
|
|
base table."
|
|
AUGMENTS { dot1agCfmMepDbEntry }
|
|
::= { tmnxDot1agCfmMepDbTable 1 }
|
|
|
|
TmnxDot1agCfmMepDbEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepDbGraceRx TruthValue,
|
|
tmnxDot1agCfmMepDbMccEdRx TruthValue
|
|
}
|
|
|
|
tmnxDot1agCfmMepDbGraceRx OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepDbGraceRx indicates whether the remote
|
|
peer is transmitting a grace period notification or not."
|
|
::= { tmnxDot1agCfmMepDbEntry 1 }
|
|
|
|
tmnxDot1agCfmMepDbMccEdRx OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepDbMccEdRx indicates whether the remote
|
|
peer is transmitting MCC-ED notifications or not."
|
|
::= { tmnxDot1agCfmMepDbEntry 2 }
|
|
|
|
tmnxDot1agCfmMepOpcodeTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepOpcodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmMepOpcodeTable consists of statistics that are kept in
|
|
the receive and transmit direction on a MEP for each CFM PDU Opcode."
|
|
REFERENCE
|
|
"Y.1731 clauses 8 and 9"
|
|
::= { tmnxDot1agCfmMep 9 }
|
|
|
|
tmnxDot1agCfmMepOpcodeEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepOpcodeEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A Mep Opcode Stats Table entry."
|
|
INDEX {
|
|
dot1agCfmMdIndex,
|
|
dot1agCfmMaIndex,
|
|
dot1agCfmMepIdentifier,
|
|
tmnxDot1agCfmMepOpcode
|
|
}
|
|
::= { tmnxDot1agCfmMepOpcodeTable 1 }
|
|
|
|
TmnxDot1agCfmMepOpcodeEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepOpcode Dot1agCfmStatisticOpcodeName,
|
|
tmnxDot1agCfmMepOpcodeRx Counter32,
|
|
tmnxDot1agCfmMepOpcodeTx Counter32
|
|
}
|
|
|
|
tmnxDot1agCfmMepOpcode OBJECT-TYPE
|
|
SYNTAX Dot1agCfmStatisticOpcodeName
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepOpcode specifies the CFM PDU Opcode to
|
|
which the statistics refer."
|
|
::= { tmnxDot1agCfmMepOpcodeEntry 1 }
|
|
|
|
tmnxDot1agCfmMepOpcodeRx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of PDUs received on the MEP with the specified
|
|
Opcode."
|
|
::= { tmnxDot1agCfmMepOpcodeEntry 2 }
|
|
|
|
tmnxDot1agCfmMepOpcodeTx OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The total number of PDUs transmitted from the MEP with the specified
|
|
Opcode."
|
|
::= { tmnxDot1agCfmMepOpcodeEntry 3 }
|
|
|
|
tmnxDot1agCfmMepExtOpTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMepExtOpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MEP Extended Operational Table augments the Maintenance
|
|
Association End Point (MEP) table of the IEEE8021-CFM-MIB,
|
|
dot1agCfmMepTable.
|
|
|
|
This table is a continuation from the Nokia SROS product series CFM
|
|
Mep table, tmnxDot1agCfmMepTable. It is intended for read-only
|
|
objects."
|
|
::= { tmnxDot1agCfmMep 10 }
|
|
|
|
tmnxDot1agCfmMepExtOpEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepExtOpEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A conceptual row in the tmnxDot1agCfmMepExtOpTable. This row exists
|
|
only if the association dot1agCfmMepEntry is active."
|
|
AUGMENTS { dot1agCfmMepEntry }
|
|
::= { tmnxDot1agCfmMepExtOpTable 1 }
|
|
|
|
TmnxDot1agCfmMepExtOpEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMepOpRxPeerGrace TruthValue,
|
|
tmnxDot1agCfmMepCcmTxRdi TruthValue,
|
|
tmnxDot1agCfmMepCcmTxPortStatus Dot1agCfmPortStatus,
|
|
tmnxDot1agCfmMepCcmTxIfStatus Dot1agCfmInterfaceStatus,
|
|
tmnxDot1agCfmMepTxAis INTEGER,
|
|
tmnxDot1agCfmMepTxGrace INTEGER,
|
|
tmnxDot1agCfmMepTxCcm INTEGER,
|
|
tmnxDot1agCfmMepEthBnNominalBw Integer32,
|
|
tmnxDot1agCfmMepEthBnCurrentBw Integer32,
|
|
tmnxDot1agCfmMepEthBnReportedBw Integer32,
|
|
tmnxDot1agCfmMepEthBnLastReport DateAndTime,
|
|
tmnxDot1agCfmMepEthBnUpdPacTimer TimeInterval,
|
|
tmnxDot1agCfmMepEthBnPortId Unsigned32,
|
|
tmnxDot1agCfmMepEthBnRxInterval Unsigned32
|
|
}
|
|
|
|
tmnxDot1agCfmMepOpRxPeerGrace OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepOpRxPeerGrace indicates whether the local
|
|
MEP is receiving and processing grace notifications from one or more
|
|
peer MEPs. A value of 'true (1)' indicates the local MEP is
|
|
receiving and processing grace from at least one peer MEP. A value
|
|
of 'false (2)' indicates that no peer grace notifications are being
|
|
received and processed."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMepExtOpEntry 1 }
|
|
|
|
tmnxDot1agCfmMepCcmTxRdi OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCcmTxRdi indicates whether or not the
|
|
Remote Defect Indication (RDI) bit was set on the most recent
|
|
Connectivity Check Message (CCM) transmission from the local MEP.
|
|
|
|
If the value of dot1agCfmMepActive or dot1agCfmMepCciEnabled is set to
|
|
'false (2)', or if the RDI bit was not set in the most recent
|
|
transmission, then tmnxDot1agCfmMepCcmTxRdi will return a value of
|
|
'false (2)'."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 2 }
|
|
|
|
tmnxDot1agCfmMepCcmTxPortStatus OBJECT-TYPE
|
|
SYNTAX Dot1agCfmPortStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCcmTxPortStatus indicates the port status
|
|
TLV information included in the most recent Connectivity Check Message
|
|
(CCM) transmission from the local MEP.
|
|
|
|
If the value of dot1agCfmMepActive or dot1agCfmMepCciEnabled value is
|
|
set to 'false (2)', or if no port status TLV was included in the most
|
|
recent transmission, then tmnxDot1agCfmMepCcmTxPortStatus will return
|
|
a value of 'psNoPortStateTLV (0)'."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 3 }
|
|
|
|
tmnxDot1agCfmMepCcmTxIfStatus OBJECT-TYPE
|
|
SYNTAX Dot1agCfmInterfaceStatus
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepCcmTxIfStatus indicates the interface
|
|
status TLV information included in the most recent Connectivity Check
|
|
Message (CCM) transmission from the local MEP.
|
|
|
|
If the value of dot1agCfmMepActive or dot1agCfmMepCciEnabled value is
|
|
set to 'false (2)', or if no interface status TLV was included in the
|
|
most recent transmission, then tmnxDot1agCfmMepCcmTxIfStatus will
|
|
return a value of 'isNoInterfaceStatusTLV (0)'."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 4 }
|
|
|
|
tmnxDot1agCfmMepTxAis OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTransmit (0),
|
|
transmit (1),
|
|
pending (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTxAis indicates the state of the MEP AIS
|
|
PDU transmission.
|
|
|
|
Values:
|
|
noTransmit (0) - no AIS PDUs are being transmitted by the MEP
|
|
transmit (1) - MEP is currently transmitting AIS PDUs
|
|
pending (2) - MEP should be transmitting AIS PDUs but cannot due
|
|
to lack of resources or some other reason"
|
|
::= { tmnxDot1agCfmMepExtOpEntry 5 }
|
|
|
|
tmnxDot1agCfmMepTxGrace OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTransmit (0),
|
|
grace (1),
|
|
ethEd (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTxGrace indicates the state of the MEP
|
|
grace period PDU transmission.
|
|
|
|
Values:
|
|
noTransmit (0) - no grace PDUs are being transmitted by the MEP
|
|
grace (1) - MEP is currently transmitting grace period PDUs
|
|
eth-ed (2) - MEP is currently transmitting Ethernet Expected
|
|
Defect (ETH-ED) PDUs"
|
|
::= { tmnxDot1agCfmMepExtOpEntry 6 }
|
|
|
|
tmnxDot1agCfmMepTxCcm OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
noTransmit (0),
|
|
transmit (1),
|
|
suppressed (2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepTxCcm indicates the state of the MEP CCM
|
|
PDU transmission.
|
|
|
|
Values:
|
|
noTransmit (0) - no CCM PDUs are being transmitted by the MEP
|
|
transmit (1) - MEP is currently transmitting CCM PDUs
|
|
suppressed (2) - MEP should be transmitting CCM PDUs but is suppressing
|
|
them due to an internal condition"
|
|
::= { tmnxDot1agCfmMepExtOpEntry 7 }
|
|
|
|
tmnxDot1agCfmMepEthBnNominalBw OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "megabps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnNominalBw indicates the data rate
|
|
received in the ETH-BN PDU. It is the nominal egress rate of the
|
|
physical port of the facility MEP.
|
|
|
|
A value of '-1' indicates that the rate value is not available."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 8 }
|
|
|
|
tmnxDot1agCfmMepEthBnCurrentBw OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "megabps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnCurrentBw indicates the bandwidth of
|
|
the outdoor radio link. It is received in the ETH-BN PDU. The value
|
|
advises the physical port to change its egress rate.
|
|
|
|
A value of '-1' indicates that the rate value is not available."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 9 }
|
|
|
|
tmnxDot1agCfmMepEthBnReportedBw OBJECT-TYPE
|
|
SYNTAX Integer32
|
|
UNITS "megabps"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnReportedBw indicates the most recent
|
|
egress rate that the MEP reported to its port. The most recently
|
|
received current bandwidth in an ETH-BN message is marked as the
|
|
tmnxDot1agCfmMepEthBnReportedBw when the timer specified by
|
|
tmnxDot1agCfmMepEthBnRxUpdPacing expires.
|
|
|
|
A value of '-1' indicates that the rate value is not available."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 10 }
|
|
|
|
tmnxDot1agCfmMepEthBnLastReport OBJECT-TYPE
|
|
SYNTAX DateAndTime (SIZE (11))
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnLastReport indicates when the most
|
|
recent tmnxDot1agCfmMepEthBnReportedBw was sent to the MEP's port."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 11 }
|
|
|
|
tmnxDot1agCfmMepEthBnUpdPacTimer OBJECT-TYPE
|
|
SYNTAX TimeInterval
|
|
UNITS "centiseconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnUpdPacTimer indicates the time
|
|
interval, in centiseconds, until the next
|
|
tmnxDot1agCfmMepEthBnReportedBw value is sent to the MEP's port."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 12 }
|
|
|
|
tmnxDot1agCfmMepEthBnPortId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnPortId indicates the port id
|
|
received in the ETH-BN PDU."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 13 }
|
|
|
|
tmnxDot1agCfmMepEthBnRxInterval OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
UNITS "seconds"
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepEthBnRxInterval indicates the interval,
|
|
in seconds, between reception of ETH-BN PDUs."
|
|
::= { tmnxDot1agCfmMepExtOpEntry 14 }
|
|
|
|
tmnxDot1agCfmMip OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 8 }
|
|
|
|
tmnxDot1agCfmSapMipTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmSapMipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"A row in the tmnxDot1agCfmSapMipTable indicates that the specified SAP
|
|
may have a MIP created on the endpoint."
|
|
::= { tmnxDot1agCfmMip 1 }
|
|
|
|
tmnxDot1agCfmSapMipEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmSapMipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The MIP (SAP) entry"
|
|
INDEX {
|
|
tmnxDot1agCfmSapMipIfIndex,
|
|
tmnxDot1agCfmSapMipVlanIdOrNone,
|
|
tmnxDot1agCfmSapMipPrimaryVlanId
|
|
}
|
|
::= { tmnxDot1agCfmSapMipTable 1 }
|
|
|
|
TmnxDot1agCfmSapMipEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmSapMipIfIndex InterfaceIndex,
|
|
tmnxDot1agCfmSapMipVlanIdOrNone Unsigned32,
|
|
tmnxDot1agCfmSapMipRowStatus RowStatus,
|
|
tmnxDot1agCfmSapMipSrcMacAddress MacAddress,
|
|
tmnxDot1agCfmSapMipPrimaryVlanId VlanIdOrNone
|
|
}
|
|
|
|
tmnxDot1agCfmSapMipIfIndex OBJECT-TYPE
|
|
SYNTAX InterfaceIndex
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"This object represents the Bridge Port or aggregated port
|
|
on which MEPs or MHFs might be configured."
|
|
::= { tmnxDot1agCfmSapMipEntry 1 }
|
|
|
|
tmnxDot1agCfmSapMipVlanIdOrNone OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"VLAN ID to which the MIP is attached, or 0, if none."
|
|
::= { tmnxDot1agCfmSapMipEntry 2 }
|
|
|
|
tmnxDot1agCfmSapMipRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmSapMipRowStatus specifies the ability to enable MIP
|
|
creation under a SAP. Existing MIPs associated with the SAP may be
|
|
viewed via the tmnxDot1agCfmStackTable."
|
|
::= { tmnxDot1agCfmSapMipEntry 3 }
|
|
|
|
tmnxDot1agCfmSapMipSrcMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSapMipSrcMacAddress specifies the source MAC
|
|
address used by the MIP.
|
|
|
|
By default, the MAC address is the MAC address of the SAP."
|
|
::= { tmnxDot1agCfmSapMipEntry 4 }
|
|
|
|
tmnxDot1agCfmSapMipPrimaryVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrNone
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSapMipPrimaryVlanId specifies primary VLAN
|
|
ID used by the MIP. A value of zero '(0)' specifies a non-primary vlan
|
|
MIP."
|
|
::= { tmnxDot1agCfmSapMipEntry 5 }
|
|
|
|
tmnxDot1agCfmSdpMipTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmSdpMipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmSdpMipTable contains the configuration information for
|
|
Maintenance domain Intermediate Points (MIPs) associated with Service
|
|
Delivery Point (SDP) bindings and primary Virtual Local Area Networks
|
|
(VLANs)."
|
|
::= { tmnxDot1agCfmMip 2 }
|
|
|
|
tmnxDot1agCfmSdpMipEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmSdpMipEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"tmnxDot1agCfmSdpMipEntry contains configuration information for a MIP.
|
|
|
|
If the primary Virtual Local Area Network (VLAN) index of the row (i.e.
|
|
tmnxDot1agCfmSdpMipPrimaryVlanId) is zero, the MIP is configured
|
|
against an SDP binding. Otherwise, the MIP is configured against an
|
|
SDP binding and a Primary VLAN identifier.
|
|
|
|
Rows are created or destroyed using tmnxDot1agCfmSdpMipRowStatus."
|
|
INDEX {
|
|
tmnxDot1agCfmSdpMipSvcId,
|
|
tmnxDot1agCfmSdpMipSdpId,
|
|
tmnxDot1agCfmSdpMipVcId,
|
|
tmnxDot1agCfmSdpMipPrimaryVlanId
|
|
}
|
|
::= { tmnxDot1agCfmSdpMipTable 1 }
|
|
|
|
TmnxDot1agCfmSdpMipEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmSdpMipSvcId TmnxServId,
|
|
tmnxDot1agCfmSdpMipSdpId SdpId,
|
|
tmnxDot1agCfmSdpMipVcId Unsigned32,
|
|
tmnxDot1agCfmSdpMipRowStatus RowStatus,
|
|
tmnxDot1agCfmSdpMipSrcMacAddress MacAddress,
|
|
tmnxDot1agCfmSdpMipPrimaryVlanId VlanIdOrNone
|
|
}
|
|
|
|
tmnxDot1agCfmSdpMipSvcId OBJECT-TYPE
|
|
SYNTAX TmnxServId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpMipSvcId specifies the service identifier
|
|
index of the row."
|
|
::= { tmnxDot1agCfmSdpMipEntry 1 }
|
|
|
|
tmnxDot1agCfmSdpMipSdpId OBJECT-TYPE
|
|
SYNTAX SdpId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpMipSdpId specifies the SDP identifier
|
|
index of the row."
|
|
::= { tmnxDot1agCfmSdpMipEntry 2 }
|
|
|
|
tmnxDot1agCfmSdpMipVcId OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpMipVcId specifies the Virtual Circuit
|
|
(VC) identifier index of the row."
|
|
::= { tmnxDot1agCfmSdpMipEntry 3 }
|
|
|
|
tmnxDot1agCfmSdpMipRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpMipRowStatus specifies the status of the
|
|
row. Creating/destroying a row creates/destroys a MIP."
|
|
::= { tmnxDot1agCfmSdpMipEntry 4 }
|
|
|
|
tmnxDot1agCfmSdpMipSrcMacAddress OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpMipSrcMacAddress specifies the source MAC
|
|
address used by the MIP.
|
|
|
|
When the all-zeros MAC address is configured, SROS uses the chassis
|
|
MAC address (i.e. TIMETRA-CHASSIS-MIB::tmnxChassisBaseMacAddress) as
|
|
the MIP's source MAC address."
|
|
DEFVAL { '000000000000'H }
|
|
::= { tmnxDot1agCfmSdpMipEntry 5 }
|
|
|
|
tmnxDot1agCfmSdpMipPrimaryVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrNone
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmSdpMipPrimaryVlanId specifies the Primary
|
|
VLAN identifier index of the row.
|
|
|
|
The tmnxDot1agCfmSdpMipEntry DESCRIPTION clause describes the
|
|
tmnxDot1agCfmSdpMipPrimaryVlanId = 0 case.
|
|
|
|
This index was added to the table in SROS release 15.0 R1."
|
|
::= { tmnxDot1agCfmSdpMipEntry 6 }
|
|
|
|
tmnxDot1agCfmNotificationObjs OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 9 }
|
|
|
|
tmnxDot1agCfmNotifySvcId OBJECT-TYPE
|
|
SYNTAX TmnxServId
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmNotifySvcId is used in notifications when a row
|
|
consisting of the service identifier may not exist when the trap is
|
|
issued."
|
|
::= { tmnxDot1agCfmNotificationObjs 1 }
|
|
|
|
tmnxDot1agCfmMepFcltyType OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMepFclty
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFcltyType indicates the type of facility
|
|
that a facility MEP has affected via a raised or cleared event."
|
|
::= { tmnxDot1agCfmNotificationObjs 2 }
|
|
|
|
tmnxDot1agCfmMepFcltyInstance OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMepFcltyInstance indicates the specific
|
|
facility instance that a facility MEP has affected via a raised or
|
|
cleared event.
|
|
|
|
This value is used in combination with its tmnxDot1agCfmMepFcltyType.
|
|
|
|
The possible facility types and instance forms are described in the
|
|
following table:
|
|
|
|
Facility Type | Facility Instance
|
|
---------------------------------------------
|
|
port | slot/mda/port
|
|
lag | lag-id
|
|
networkInterface | interface name
|
|
qinqPortTunnelSap | sap-id
|
|
qinqLagTunnelSap | sap-id
|
|
|
|
The combined value will appear as in the following examples:
|
|
port 7/2/2
|
|
lag 1
|
|
networkInterface test
|
|
qinqPortTunnelSap 2/2/2:100.*
|
|
qinqLagTunnelSap lag-1:100.*
|
|
|
|
When a facility fault occurs on a QinQ port or lag, the sap executing
|
|
the CFM functional test, the sap will be included as part of the
|
|
event log message. However, QinQ facility tunnel MEPs on the sap are
|
|
only the detection point for the defect / clear condition. The QinQ
|
|
facility tunnel is port or lag based and a representative outer tag."
|
|
::= { tmnxDot1agCfmNotificationObjs 3 }
|
|
|
|
tmnxDot1agCfmDefaultMd OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 10 }
|
|
|
|
tmnxDot1agCfmDfltMdDefMipLtrPrio OBJECT-TYPE
|
|
SYNTAX Integer32 (0..7)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmDfltMdDefMipLtrPrio indicates at what
|
|
priority the link-trace response frames should be transmitted for a
|
|
MIP request, for each tmnxDot1agCfmDefaultMdEntry whose
|
|
tmnxDot1agCfmDefaultMdMipLtrPrio object contains the value '-1'.
|
|
|
|
This object defaults to, and only supports the value '7'."
|
|
::= { tmnxDot1agCfmDefaultMd 1 }
|
|
|
|
tmnxDot1agCfmDefaultMdTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmDefaultMdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmDefaultMdTable AUGMENTS the standard MIB table,
|
|
dot1agCfmDefaultMdTable. This table is used to enhance the Default
|
|
Maintenance Domain functionality for Ethernet Connectivity Fault
|
|
Management (Eth-CFM)."
|
|
::= { tmnxDot1agCfmDefaultMd 2 }
|
|
|
|
tmnxDot1agCfmDefaultMdEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmDefaultMdEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmDefaultMdEntry consists of the configuration objects
|
|
used to enhance the Default Maintenance Domain functionality."
|
|
AUGMENTS { dot1agCfmDefaultMdEntry }
|
|
::= { tmnxDot1agCfmDefaultMdTable 1 }
|
|
|
|
TmnxDot1agCfmDefaultMdEntry ::= SEQUENCE
|
|
{ tmnxDot1agCfmDefaultMdMipLtrPrio Integer32 }
|
|
|
|
tmnxDot1agCfmDefaultMdMipLtrPrio OBJECT-TYPE
|
|
SYNTAX Integer32 (-1 | 0..7)
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmDefaultMdMipLtrPrio specifies at what
|
|
priority the link-trace response frames should be transmitted for a
|
|
MIP request.
|
|
|
|
If this object has the value '-1', the priority of this entry is
|
|
deferred to tmnxDot1agCfmDfltMdDefMipLtrPrio."
|
|
DEFVAL { -1 }
|
|
::= { tmnxDot1agCfmDefaultMdEntry 1 }
|
|
|
|
tmnxDot1agLearnedRemoteMacObjs OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 11 }
|
|
|
|
tmnxDot1agCfmLearnedRmtMacTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmLearnedRmtMacEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmLearnedRmtMacTable stores the remote MEP MAC
|
|
addresses that have been learned when receiving CCM PDUs on a local
|
|
MEP."
|
|
::= { tmnxDot1agLearnedRemoteMacObjs 1 }
|
|
|
|
tmnxDot1agCfmLearnedRmtMacEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmLearnedRmtMacEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmLearnedRmtMacEntry consists of the remote MEP MAC
|
|
address that has been learned by a local MEP as well as information
|
|
about the state of the remote MEP MAC address.
|
|
|
|
Rows are managed by the system and can not be created or destroyed
|
|
using SNMP set requests."
|
|
INDEX {
|
|
dot1agCfmMdIndex,
|
|
dot1agCfmMaIndex,
|
|
dot1agCfmMepIdentifier,
|
|
tmnxDot1agCfmLearnedRmtMepId
|
|
}
|
|
::= { tmnxDot1agCfmLearnedRmtMacTable 1 }
|
|
|
|
TmnxDot1agCfmLearnedRmtMacEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmLearnedRmtMepId Dot1agCfmMepId,
|
|
tmnxDot1agCfmLearnedRmtMacAddr MacAddress,
|
|
tmnxDot1agCfmLearnedRmtStaleFlag TruthValue,
|
|
tmnxDot1agCfmLearnedRmtChngdFlag TruthValue
|
|
}
|
|
|
|
tmnxDot1agCfmLearnedRmtMepId OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMepId
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmLearnedRmtMepId indicates the remote MEP
|
|
identifier associated with the entry."
|
|
::= { tmnxDot1agCfmLearnedRmtMacEntry 1 }
|
|
|
|
tmnxDot1agCfmLearnedRmtMacAddr OBJECT-TYPE
|
|
SYNTAX MacAddress
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmLearnedRmtMacAddr indicates the source MAC
|
|
address used by the remote MEP in the most recently received CCM PDU."
|
|
::= { tmnxDot1agCfmLearnedRmtMacEntry 2 }
|
|
|
|
tmnxDot1agCfmLearnedRmtStaleFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmLearnedRmtStaleFlag indicates if the learned
|
|
MAC entry for this remote MEP matches the entry found in the
|
|
dot1agCfmMepDbTable.
|
|
|
|
The value 'false' indicates that the MAC address matches the entry
|
|
found in both the tables for the same local and remote MEP values and
|
|
therefore is not considered stale.
|
|
|
|
The value 'true' indicates either the entries do not match, or there
|
|
is no equivalent entry for the remote MEP in the dot1agCfmMepDbTable
|
|
so the learned remote MAC address in this table is considered stale."
|
|
::= { tmnxDot1agCfmLearnedRmtMacEntry 3 }
|
|
|
|
tmnxDot1agCfmLearnedRmtChngdFlag OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmLearnedRmtChngdFlag indicates if the learned
|
|
MAC entry for this remote MEP has been modified in the last CCM
|
|
interval of the local MEP.
|
|
|
|
The value 'true' indicates that the local MEP received a CCM from the
|
|
remote MEP with a MAC address that does not match the address in the
|
|
tmnxDot1agCfmLearnedRmtMacAddr from the last CCM interval of the local
|
|
MEP. The new address will be stored in tmnxDot1agCfmLearnedRmtMacAddr.
|
|
|
|
The value 'false' indicates a new entry or an entry where
|
|
tmnxDot1agCfmLearnedRmtMacAddr has not changed in over one CCM
|
|
interval.
|
|
|
|
This object can be used to detect if a remote MEP MAC address has
|
|
recently changed. This may help detect configuration changes of
|
|
remote MEP MAC addresses, or possibly duplicate remote MEPs configured
|
|
in the network."
|
|
::= { tmnxDot1agCfmLearnedRmtMacEntry 4 }
|
|
|
|
tmnxDot1agCfmMdMgmt OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 12 }
|
|
|
|
tmnxDot1agCfmMdMgmtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMdMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMdMgmtTable manages the row creation and deletion of
|
|
dot1agCfmMdTable rows. This table replaces the standard row creation
|
|
model for Dot1ag CFM Maintenance Domains to better facilitate Nokia
|
|
SROS series requirements. The use of writing to the
|
|
IEEE-8021-CFM-MIB::dot1agCfmMdRowStatus object is deprecated and
|
|
should be discouraged in favor of this table."
|
|
::= { tmnxDot1agCfmMdMgmt 1 }
|
|
|
|
tmnxDot1agCfmMdMgmtEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMdMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMdMgmtEntry consists of the configuration objects
|
|
used for the purpose of row creation for Nokia SROS Dot1ag Maintenance
|
|
Domains."
|
|
AUGMENTS { dot1agCfmMdEntry }
|
|
::= { tmnxDot1agCfmMdMgmtTable 1 }
|
|
|
|
TmnxDot1agCfmMdMgmtEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMdMgmtRowStatus RowStatus,
|
|
tmnxDot1agCfmMdMgmtFormat Dot1agCfmMaintDomainNameType,
|
|
tmnxDot1agCfmMdMgmtName TmnxDot1agCfmMaintDomainNameOrEmpty,
|
|
tmnxDot1agCfmMdMgmtMdLevel Dot1agCfmMDLevel,
|
|
tmnxDot1agCfmMdMgmtAdminName TLNamedItemOrEmpty
|
|
}
|
|
|
|
tmnxDot1agCfmMdMgmtRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMdMgmtRowStatus specifies the row status of
|
|
the dot1ag CFM MEP. This object replaces the use of the
|
|
IEEE-8021-CFM-MIB::dot1agCfmMdRowStatus object."
|
|
::= { tmnxDot1agCfmMdMgmtEntry 1 }
|
|
|
|
tmnxDot1agCfmMdMgmtFormat OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMaintDomainNameType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMdMgmtFormat specifies the type (and thereby
|
|
format) of the Maintenance Domain Name.
|
|
|
|
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMdFormat.
|
|
|
|
This object may be specified only during row creation."
|
|
DEFVAL { charString }
|
|
::= { tmnxDot1agCfmMdMgmtEntry 2 }
|
|
|
|
tmnxDot1agCfmMdMgmtName OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaintDomainNameOrEmpty
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMdMgmtName specifies the Maintenance Domain
|
|
name. The type/format of this object is determined by the value of the
|
|
dot1agCfmMdNameType object.
|
|
|
|
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMdName.
|
|
|
|
This object may be specified only during row creation."
|
|
DEFVAL { '44454641554c54'H }
|
|
::= { tmnxDot1agCfmMdMgmtEntry 3 }
|
|
|
|
tmnxDot1agCfmMdMgmtMdLevel OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMDLevel
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMdMgmtMdLevel specifies the Maintenance
|
|
Domain level.
|
|
|
|
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMdMdLevel.
|
|
|
|
This object may be specified only during row creation."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMdMgmtEntry 4 }
|
|
|
|
tmnxDot1agCfmMdMgmtAdminName OBJECT-TYPE
|
|
SYNTAX TLNamedItemOrEmpty
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMdMgmtAdminName specifies a name that can be
|
|
used to uniquely identify a CFM Maintenance Domain. Historically, only
|
|
the arbitrary integer index, dot1agCfmMdIndex, would be used for this
|
|
purpose. A string provides greater flexibility and allows some amount
|
|
of context to also be included.
|
|
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMdAdminName.
|
|
|
|
This object must be specified during row creation."
|
|
DEFVAL { ''H }
|
|
::= { tmnxDot1agCfmMdMgmtEntry 5 }
|
|
|
|
tmnxDot1agCfmMaMgmt OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 13 }
|
|
|
|
tmnxDot1agCfmMaMgmtTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMaMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaMgmtTable manages the row creation and deletion of
|
|
dot1agCfmMaNetTable rows. This table replaces the standard row
|
|
creation model for Dot1ag CFM Maintenance Domain Associations to
|
|
better facilitate Nokia SROS series requirements. The use of writing
|
|
to the IEEE-8021-CFM-MIB::dot1agCfmMaNetRowStatus object is deprecated
|
|
and should be discouraged in favor of this table."
|
|
::= { tmnxDot1agCfmMaMgmt 1 }
|
|
|
|
tmnxDot1agCfmMaMgmtEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaMgmtEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaMgmtEntry consists of the configuration objects
|
|
used for the purpose of row creation for Nokia SROS Dot1ag Maintenance
|
|
Domain Associations."
|
|
AUGMENTS { dot1agCfmMaNetEntry }
|
|
::= { tmnxDot1agCfmMaMgmtTable 1 }
|
|
|
|
TmnxDot1agCfmMaMgmtEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMaMgmtRowStatus RowStatus,
|
|
tmnxDot1agCfmMaMgmtFormat TmnxDot1agCfmMaintAssocNameType,
|
|
tmnxDot1agCfmMaMgmtName Dot1agCfmMaintAssocName,
|
|
tmnxDot1agCfmMaMgmtCcmInterval TmnxDot1agCfmCcmInterval,
|
|
tmnxDot1agCfmMaMgmtAdminName TLNamedItemOrEmpty,
|
|
tmnxDot1agCfmMaMgmtHoldDownTimer Unsigned32,
|
|
tmnxDot1agCfmMaMgmtAutoDiscAdmin TruthValue,
|
|
tmnxDot1agCfmMaMgmtIdPermission TmnxDot1agCfmIdPermission
|
|
}
|
|
|
|
tmnxDot1agCfmMaMgmtRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMgmtRowStatus specifies the row status of
|
|
the dot1ag CFM Maintenance Association. This object replaces the use
|
|
of the IEEE-8021-CFM-MIB::dot1agCfmMaNetRowStatus object."
|
|
::= { tmnxDot1agCfmMaMgmtEntry 1 }
|
|
|
|
tmnxDot1agCfmMaMgmtFormat OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaintAssocNameType
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMgmtFormat specifies the type (and thereby
|
|
format) of the Maintenance Association Name.
|
|
|
|
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMaNetFormat.
|
|
|
|
This object may be specified only during row creation."
|
|
::= { tmnxDot1agCfmMaMgmtEntry 2 }
|
|
|
|
tmnxDot1agCfmMaMgmtName OBJECT-TYPE
|
|
SYNTAX Dot1agCfmMaintAssocName
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMgmtName specifies the Short Maintenance
|
|
Association name. The type/format of this object is determined by the
|
|
value of the dot1agCfmMaNetNameType object. This name must be unique
|
|
within a maintenance domain.
|
|
|
|
This object refers directly to IEEE8021-CFM-MIB::dot1agCfmMaNetName.
|
|
|
|
This object may be specified only during row creation."
|
|
::= { tmnxDot1agCfmMaMgmtEntry 3 }
|
|
|
|
tmnxDot1agCfmMaMgmtCcmInterval OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmCcmInterval
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMgmtCcmInterval specifies the interval
|
|
between CCM transmissions to be used by all MEPs in the MA.
|
|
|
|
This object refers directly to
|
|
IEEE8021-CFM-MIB::dot1agCfmMaNetCcmInterval."
|
|
DEFVAL { interval10s }
|
|
::= { tmnxDot1agCfmMaMgmtEntry 4 }
|
|
|
|
tmnxDot1agCfmMaMgmtAdminName OBJECT-TYPE
|
|
SYNTAX TLNamedItemOrEmpty
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMgmtAdminName specifies a name that can be
|
|
used to uniquely identify a CFM Maintenance Association. Historically,
|
|
only the arbitrary integer index, dot1agCfmMaIndex, would be used for
|
|
this purpose. A string provides greater flexibility and allows some
|
|
amount of context to also be included.
|
|
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaNetAdminName.
|
|
|
|
This object must be specified during row creation."
|
|
DEFVAL { ''H }
|
|
::= { tmnxDot1agCfmMaMgmtEntry 5 }
|
|
|
|
tmnxDot1agCfmMaMgmtHoldDownTimer OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0 | 1..1000)
|
|
UNITS "centiseconds"
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMgmtHoldDownTimer specifies the time, in
|
|
centiseconds, that a MEP in the association will delay declaring a
|
|
fault. This delay is added on to the existing
|
|
3.5 * dot1agCfmMaNetCcmInterval value used to determine if a
|
|
connectivity fault to the peer should be raised.
|
|
|
|
A value of zero (0) indicates that no additional delay should be added
|
|
to the existing 3.5 * dot1agCfmMaNetCcmInterval value.
|
|
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaNetHoldDownTimer."
|
|
DEFVAL { 0 }
|
|
::= { tmnxDot1agCfmMaMgmtEntry 6 }
|
|
|
|
tmnxDot1agCfmMaMgmtAutoDiscAdmin OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMgmtAutoDiscAdmin specifies if remote MEP
|
|
automatic discovery is enabled in the association. A value of 'true'
|
|
indicates that a new remote MEP entry will be added to the
|
|
dot1agCfmMepDbTable when the node receives a CCM PDU from a remote
|
|
MEP that is not yet in that table (up to the maximum limit of MEPs
|
|
allowed in the association). A value of 'false' indicates that remote
|
|
MEPs must be manually configured in the association
|
|
dot1agCfmMaMepListTable before being added to the association
|
|
dot1agCfmMepDbTable.
|
|
This object refers directly to
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaNetAutoDiscAdmin."
|
|
DEFVAL { false }
|
|
::= { tmnxDot1agCfmMaMgmtEntry 7 }
|
|
|
|
tmnxDot1agCfmMaMgmtIdPermission OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmIdPermission
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaMgmtIdPermission specifies what, if
|
|
anything, is to be included in the Sender ID TLV (21.5.3) transmitted
|
|
by MPs configured in this MA. This object is configurable on MA
|
|
entries that do not consist of component entries. This object refers
|
|
directly to TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaNetIdPermission."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.6.1.3:d"
|
|
DEFVAL { sendIdNone }
|
|
::= { tmnxDot1agCfmMaMgmtEntry 8 }
|
|
|
|
tmnxDot1agCfmMaBrName OBJECT IDENTIFIER ::= { tmnxDot1agMIBObjs 14 }
|
|
|
|
tmnxDot1agCfmMaBrNameTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF TmnxDot1agCfmMaBrNameEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaBrNameTable optionally replaces the standard row
|
|
creation model for Dot1ag CFM Maintenance Domain Association
|
|
Components. The tmnxDot1agCfmMaBrNameId allows for named references
|
|
linking to the bridging instance. The use of writing to the
|
|
IEEE-8021-CFM-MIB::dot1agCfmMaCompRowStatus object is mutually
|
|
exclusive from writing to the
|
|
TIMETRA-IEEE8021-CFM-MIB::tmnxDot1agCfmMaBrNameRowStatus."
|
|
::= { tmnxDot1agCfmMaBrName 1 }
|
|
|
|
tmnxDot1agCfmMaBrNameEntry OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMaBrNameEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMaBrNameEntry consists of the configuration objects
|
|
used for the purpose of row creation for Nokia SROS Dot1ag Maintenance
|
|
Domain Association Components using a name as a key."
|
|
INDEX {
|
|
tmnxDot1agCfmMaBrNameId,
|
|
dot1agCfmMdIndex,
|
|
dot1agCfmMaIndex
|
|
}
|
|
::= { tmnxDot1agCfmMaBrNameTable 1 }
|
|
|
|
TmnxDot1agCfmMaBrNameEntry ::= SEQUENCE
|
|
{
|
|
tmnxDot1agCfmMaBrNameId TLNamedItem,
|
|
tmnxDot1agCfmMaBrNamePVlanId VlanIdOrNone,
|
|
tmnxDot1agCfmMaBrNameMhfCreation TmnxDot1agCfmMhfCreation,
|
|
tmnxDot1agCfmMaBrNameIdPerm TmnxDot1agCfmIdPermission,
|
|
tmnxDot1agCfmMaBrNameMipLtrPrio Unsigned32,
|
|
tmnxDot1agCfmMaBrNameNumOfVids Unsigned32,
|
|
tmnxDot1agCfmMaBrNameRowStatus RowStatus
|
|
}
|
|
|
|
tmnxDot1agCfmMaBrNameId OBJECT-TYPE
|
|
SYNTAX TLNamedItem
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaBrNameId specifies a name that can be used
|
|
to uniquely identify a CFM Maintenance Association Component.
|
|
Historically, only the arbitrary integer index,
|
|
dot1agCfmMaComponentId, would be used for this purpose. A string
|
|
provides greater flexibility and allows some amount of context to also
|
|
be included."
|
|
::= { tmnxDot1agCfmMaBrNameEntry 1 }
|
|
|
|
tmnxDot1agCfmMaBrNamePVlanId OBJECT-TYPE
|
|
SYNTAX VlanIdOrNone
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaBrNamePVlanId specifies the Primary VLAN
|
|
ID with which the Maintenance Association is associated, or 0 if the
|
|
MA is not attached to any VID. If the MA is associated with more than
|
|
one VID, the dot1agCfmVlanTable lists them."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.6.1.3:b"
|
|
::= { tmnxDot1agCfmMaBrNameEntry 2 }
|
|
|
|
tmnxDot1agCfmMaBrNameMhfCreation OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmMhfCreation
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaBrNameMhfCreation specifies if the
|
|
Management entity can create MHFs (MIP Half Function) for this MA."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.6.1.3:c"
|
|
DEFVAL { defMHFnone }
|
|
::= { tmnxDot1agCfmMaBrNameEntry 3 }
|
|
|
|
tmnxDot1agCfmMaBrNameIdPerm OBJECT-TYPE
|
|
SYNTAX TmnxDot1agCfmIdPermission
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaBrNameIdPerm specifies what, if anything,
|
|
is to be included in the Sender ID TLV (21.5.3) transmitted by MPs
|
|
configured in this MA."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.6.1.3:d"
|
|
DEFVAL { sendIdNone }
|
|
::= { tmnxDot1agCfmMaBrNameEntry 4 }
|
|
|
|
tmnxDot1agCfmMaBrNameMipLtrPrio OBJECT-TYPE
|
|
SYNTAX Unsigned32 (0..7)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaBrNameMipLtrPrio specifies at what
|
|
priority the link-trace response frames should be transmitted for a
|
|
MIP request."
|
|
DEFVAL { 7 }
|
|
::= { tmnxDot1agCfmMaBrNameEntry 5 }
|
|
|
|
tmnxDot1agCfmMaBrNameNumOfVids OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaBrNameNumOfVids indicates the number of
|
|
VIDs associated with the MA."
|
|
REFERENCE
|
|
"802.1ag clause 12.14.6.1.3:b"
|
|
::= { tmnxDot1agCfmMaBrNameEntry 6 }
|
|
|
|
tmnxDot1agCfmMaBrNameRowStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The value of tmnxDot1agCfmMaBrNameRowStatus specifies the row status
|
|
of the dot1ag CFM Maintenance Association. This object optionally
|
|
replaces the use of the IEEE-8021-CFM-MIB::dot1agCfmMaCompRowStatus
|
|
object."
|
|
::= { tmnxDot1agCfmMaBrNameEntry 7 }
|
|
|
|
tmnxDot1agMIBConformance OBJECT IDENTIFIER ::= { tmnxSRConfs 52 }
|
|
|
|
tmnxDot1agCfmCompliances OBJECT IDENTIFIER ::= { tmnxDot1agMIBConformance 1 }
|
|
|
|
tmnxDot1agCfmCompliance MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for revision 1.0 of TIMETRA-IEEE8021-CFM-MIB."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmSdpBindStackGroup,
|
|
tmnxDot1agCfmMepGroup,
|
|
tmnxDot1agCfmSapStackGroup
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 1 }
|
|
|
|
tmnxDot1agCfmComplianceV7v0 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for revision 7.0 of the SROS system"
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmSdpBindStackGroup,
|
|
tmnxDot1agCfmSapStackGroup,
|
|
tmnxDot1agCfmNotificationGroup,
|
|
tmnxY1731CfmNotificationGroup,
|
|
tmnxDot1agCfmMipGroup,
|
|
tmnxDot1agCfmMipNotifyGroup,
|
|
tmnxDot1agCfmMepGroupV7v0
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 2 }
|
|
|
|
tmnxDot1agCfmComplianceV8v0 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for revision 8.0 of the SROS system"
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmSdpBindStackGroup,
|
|
tmnxDot1agCfmSapStackGroup,
|
|
tmnxDot1agCfmNotificationGroup,
|
|
tmnxY1731CfmNotificationGroup,
|
|
tmnxDot1agCfmMipNotifyGroup,
|
|
tmnxDot1agCfmMipGroupV8v0,
|
|
tmnxDot1agCfmMepGroupV7v0,
|
|
tmnxDot1agCfmMepGroupV8v0
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 3 }
|
|
|
|
tmnxDot1agCfmComplianceV9v0 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for revision 9.0 of the SROS system"
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmMaGroupV9v0,
|
|
tmnxDot1agCfmSdpBindStackGroup,
|
|
tmnxDot1agCfmSapStackGroup,
|
|
tmnxDot1agCfmNotificationGroup,
|
|
tmnxY1731CfmNotificationGroup,
|
|
tmnxDot1agCfmMipNotifyGroup,
|
|
tmnxDot1agCfmMipGroupV8v0,
|
|
tmnxDot1agCfmMepGroupV7v0,
|
|
tmnxDot1agCfmMepGroupV8v0,
|
|
tmnxDot1agCfmMepGroupV9v0,
|
|
tmnxDot1agCfmGlobalGroupV9v0,
|
|
tmnxDot1agCfmMepSlmGroupV9v0,
|
|
tmnxDot1agCfmMepSlmNotifyGroup,
|
|
tmnxDot1agCfmMepMcastLbmGroup
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 4 }
|
|
|
|
tmnxDot1agCfmComplianceV10v0 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for revision 10.0 of the SROS system"
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmGlobalGroupV9v0,
|
|
tmnxDot1agCfmMaGroupV9v0,
|
|
tmnxDot1agCfmMaGroupV10v0,
|
|
tmnxDot1agCfmMepGroupV7v0,
|
|
tmnxDot1agCfmMepGroupV8v0,
|
|
tmnxDot1agCfmMepGroupV9v0,
|
|
tmnxDot1agCfmMepGroupV10v0,
|
|
tmnxDot1agCfmMepMcastLbmGroup,
|
|
tmnxDot1agCfmMepSlmGroupV9v0,
|
|
tmnxDot1agCfmMepSlmNotifyGroup,
|
|
tmnxDot1agCfmMepSlmTWGroupV10v0,
|
|
tmnxDot1agCfmMipGroupV8v0,
|
|
tmnxDot1agCfmMipNotifyGroup,
|
|
tmnxDot1agCfmNotificationGroup,
|
|
tmnxDot1agCfmSapStackGroup,
|
|
tmnxDot1agCfmSdpBindStackGroup,
|
|
tmnxDot1agCfmStatsGroupV10v0,
|
|
tmnxY1731CfmNotificationGroup,
|
|
tmnxDot1agCfmGPGroupV10v0
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 5 }
|
|
|
|
tmnxDot1agCfmComplianceV11v0 MODULE-COMPLIANCE
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The compliance statement for revision 11.0 of the SROS system"
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmGlobalGroupV9v0,
|
|
tmnxDot1agCfmMaGroupV9v0,
|
|
tmnxDot1agCfmMaGroupV10v0,
|
|
tmnxDot1agCfmMaGroupV11v0,
|
|
tmnxDot1agCfmMepGroupV7v0,
|
|
tmnxDot1agCfmMepGroupV8v0,
|
|
tmnxDot1agCfmMepGroupV9v0,
|
|
tmnxDot1agCfmMepGroupV10v0,
|
|
tmnxDot1agCfmMepCSFGroupV11v0,
|
|
tmnxDot1agCfmMepMcastLbmGroup,
|
|
tmnxDot1agCfmMepSlmGroupV9v0,
|
|
tmnxDot1agCfmMepSlmNotifyGroup,
|
|
tmnxDot1agCfmMepSlmTWGroupV10v0,
|
|
tmnxDot1agCfmMipGroupV8v0,
|
|
tmnxDot1agCfmMipNotifyGroup,
|
|
tmnxDot1agCfmNotificationGroup,
|
|
tmnxDot1agCfmCSFNotifyGroupV11v0,
|
|
tmnxDot1agCfmSapStackGroup,
|
|
tmnxDot1agCfmSdpBindStackGroup,
|
|
tmnxDot1agCfmStatsGroupV10v0,
|
|
tmnxY1731CfmNotificationGroup,
|
|
tmnxDot1agCfmGPGroupV10v0,
|
|
tmnxDot1agCfmMEPMgmtGroupV11v0,
|
|
tmnxDot1agCfmMdGroupV11v0
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 6 }
|
|
|
|
tmnxDot1agCfmComplianceV12v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for revision 12.0 of the SROS system"
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmGlobalGroupV9v0,
|
|
tmnxDot1agCfmMaGroupV9v0,
|
|
tmnxDot1agCfmMaGroupV10v0,
|
|
tmnxDot1agCfmMaGroupV11v0,
|
|
tmnxDot1agCfmMaGroupV12v0,
|
|
tmnxDot1agCfmMepGroupV7v0,
|
|
tmnxDot1agCfmMepGroupV8v0,
|
|
tmnxDot1agCfmMepGroupV9v0,
|
|
tmnxDot1agCfmMepGroupV10v0,
|
|
tmnxDot1agCfmMepCSFGroupV11v0,
|
|
tmnxDot1agCfmMepGroupV12v0,
|
|
tmnxDot1agCfmMepMcastLbmGroup,
|
|
tmnxDot1agCfmMepSlmGroupV9v0,
|
|
tmnxDot1agCfmMepSlmNotifyGroup,
|
|
tmnxDot1agCfmMepSlmTWGroupV10v0,
|
|
tmnxDot1agCfmMipGroupV8v0,
|
|
tmnxDot1agCfmMipNotifyGroup,
|
|
tmnxDot1agCfmNotificationGroup,
|
|
tmnxDot1agCfmCSFNotifyGroupV11v0,
|
|
tmnxDot1agCfmSapStackGroup,
|
|
tmnxDot1agCfmSdpBindStackGroup,
|
|
tmnxDot1agCfmStatsGroupV10v0,
|
|
tmnxDot1agCfmStatsGroupV12v0,
|
|
tmnxY1731CfmNotificationGroup,
|
|
tmnxDot1agCfmGPGroupV10v0,
|
|
tmnxDot1agCfmMEPMgmtGroupV11v0,
|
|
tmnxDot1agCfmMdGroupV11v0,
|
|
tmnxDot1agCfmScalarsGroupV12v0
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 7 }
|
|
|
|
tmnxDot1agCfmComplianceV13v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the object groups added in SROS Release
|
|
13.0."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmMepGroupV13v0,
|
|
tmnxDot1agCfmXmppEnhGroup
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 8 }
|
|
|
|
tmnxDot1agCfmComplianceV14v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the management of Ethernet Connectivity
|
|
Fault Management (Eth-CFM) for release 14.0 on Nokia SROS series
|
|
systems."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmDefaultMdGroupV14v0,
|
|
tmnxDot1agNotifyObjsGroupV14v0,
|
|
tmnxDot1agCfmCLENotifyGroupV14v0
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 9 }
|
|
|
|
tmnxDot1agCfmComplianceV15v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the management of Ethernet Connectivity
|
|
Fault Management (Eth-CFM) for release 15.0 on Nokia SROS series
|
|
systems."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmMepGroupV15v0,
|
|
tmnxDot1agCfmTstMepIdGroupV15v0,
|
|
tmnxDot1agCfmLmmPerQosGroupV15v0,
|
|
tmnxDot1agCfmMccEdGroupV15v0,
|
|
tmnxDot1agCfmSdpPrimVLanGrpV15v0,
|
|
tmnxDot1agCfmLbmLbrMepGroupV15v0
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 10 }
|
|
|
|
tmnxDot1agCfmComplianceV15v1 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the management of Ethernet Connectivity
|
|
Fault Management (Eth-CFM) for release 15.1 on Nokia SROS series
|
|
systems."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmAdminNameGroup
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 11 }
|
|
|
|
tmnxDot1AgCfmComplianceV16v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the management of Ethernet Connectivity
|
|
Fault Management (Eth-CFM) for release 16.0 on Nokia SROS series
|
|
systems."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmEthBnGroup,
|
|
tmnxDot1agCfmMaBrNameGroup,
|
|
tmnxDot1agCfmAdminNameGroupExt,
|
|
tmnxDot1agCfmModelDrivenGroup
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 12 }
|
|
|
|
tmnxDot1agCfmComplianceV19v0 MODULE-COMPLIANCE
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The compliance statement for the management of Ethernet Connectivity
|
|
Fault Management (Eth-CFM) for release 19.5 on Nokia SROS series
|
|
systems."
|
|
MODULE
|
|
MANDATORY-GROUPS {
|
|
tmnxDot1agCfmMepIXRGroup
|
|
}
|
|
::= { tmnxDot1agCfmCompliances 13 }
|
|
|
|
tmnxDot1agCfmGroups OBJECT IDENTIFIER ::= { tmnxDot1agMIBConformance 2 }
|
|
|
|
tmnxDot1agCfmSdpBindStackGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmSdpBindStackMdIndex,
|
|
tmnxDot1agCfmSdpBindStackMaIndex,
|
|
tmnxDot1agCfmSdpBindStackMepId,
|
|
tmnxDot1agCfmSdpBindStackMacAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of dot1ag Stack Table applicable
|
|
to implementing SDP-Bindings."
|
|
::= { tmnxDot1agCfmGroups 1 }
|
|
|
|
tmnxDot1agCfmMepGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepSdpId,
|
|
tmnxDot1agCfmMepVcId,
|
|
tmnxDot1agCfmMepMacAddress
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The group of objects for management of dot1ag MEP Table applicable to
|
|
implementing SDP-Bindings."
|
|
::= { tmnxDot1agCfmGroups 2 }
|
|
|
|
tmnxDot1agCfmSapStackGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmStackMdIndex,
|
|
tmnxDot1agCfmStackMaIndex,
|
|
tmnxDot1agCfmStackMepId,
|
|
tmnxDot1agCfmStackMacAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of dot1ag Stack Table applicable
|
|
to implementing SAP on the SROS."
|
|
::= { tmnxDot1agCfmGroups 3 }
|
|
|
|
tmnxDot1agCfmNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxDot1agCfmMepLbmTestComplete,
|
|
tmnxDot1agCfmMepLtmTestComplete
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of dot1ag Notifications applicable
|
|
to implementing CFM on the SROS."
|
|
::= { tmnxDot1agCfmGroups 4 }
|
|
|
|
tmnxDot1agCfmMipGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmSapMipRowStatus,
|
|
tmnxDot1agCfmSdpMipRowStatus
|
|
}
|
|
STATUS obsolete
|
|
DESCRIPTION
|
|
"The group of objects for management of dot1ag MIP Tables applicable to
|
|
implementing MIPs."
|
|
::= { tmnxDot1agCfmGroups 5 }
|
|
|
|
tmnxDot1agCfmMepGroupV7v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepSdpId,
|
|
tmnxDot1agCfmMepVcId,
|
|
tmnxDot1agCfmMepMacAddress,
|
|
tmnxDot1agCfmMepAisEnable,
|
|
tmnxDot1agCfmMepAisMegLevel,
|
|
tmnxDot1agCfmMepAisPriority,
|
|
tmnxDot1agCfmMepAisInterval,
|
|
tmnxDot1agCfmMepEthTestEnable,
|
|
tmnxDot1agCfmMepEthTestPattern,
|
|
tmnxDot1agCfmMepEthRxAisInterval,
|
|
tmnxDot1agCfmMepEthRxAis,
|
|
tmnxDot1agCfmMepEthAisTxCount,
|
|
tmnxDot1agCfmMepEthTestMacAddr,
|
|
tmnxDot1agCfmMepEthTestDataLen,
|
|
tmnxDot1agCfmMepEthTestPriority,
|
|
tmnxDot1agCfmMepOWDTMacAddress,
|
|
tmnxDot1agCfmMepOWDTPriority,
|
|
tmnxDot1agCfmMepTWDTMacAddress,
|
|
tmnxDot1agCfmMepTWDTPriority,
|
|
tmnxDot1agCfmMepFrameCount,
|
|
tmnxDot1agCfmMepByteCount,
|
|
tmnxDot1agCfmMepFailedBits,
|
|
tmnxDot1agCfmMepCrcFailures,
|
|
tmnxDot1agCfmMepCurrByteCount,
|
|
tmnxDot1agCfmMepCurrFailedBits,
|
|
tmnxDot1agCfmMepCurrCrcFailures,
|
|
tmnxDot1agCfmMepDelayTestDelay,
|
|
tmnxDot1agCfmMepDelayVariation,
|
|
tmnxDot1agCfmMepSvcId,
|
|
tmnxDot1agCfmMepControlMep,
|
|
tmnxDot1agCfmMepEthTestThreshold,
|
|
tmnxDot1agCfmMepOWDTThreshold,
|
|
tmnxDot1agCfmVStackMdIndex,
|
|
tmnxDot1agCfmVStackMaIndex,
|
|
tmnxDot1agCfmVStackMepId,
|
|
tmnxDot1agCfmVStackMacAddress,
|
|
tmnxDot1agCfmStackMPType
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for managing dot1ag and Y.1731 tables applicable
|
|
to Virtual MEPs and MEGs on SROS R7.0, and enabling APS support."
|
|
::= { tmnxDot1agCfmGroups 6 }
|
|
|
|
tmnxY1731CfmNotificationGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxDot1agCfmMepEthTestComplete,
|
|
tmnxDot1agCfmMepDMTestComplete,
|
|
tmnxDot1agCfmMepAisStateChanged
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of Y.1731 Notifications applicable
|
|
to implementing CFM on the SROS."
|
|
::= { tmnxDot1agCfmGroups 7 }
|
|
|
|
tmnxDot1agCfmNotifyObjsGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmNotifySvcId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting notifications for revision 7.0 on
|
|
Nokia SROS series systems."
|
|
::= { tmnxDot1agCfmGroups 8 }
|
|
|
|
tmnxDot1agCfmMipNotifyGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxDot1agCfmMipEvaluation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of notification objects for management of dot1ag MIPs."
|
|
::= { tmnxDot1agCfmGroups 9 }
|
|
|
|
tmnxDot1agCfmV6v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 10 }
|
|
|
|
tmnxDot1agCfmV7v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 11 }
|
|
|
|
tmnxDot1agCfmV8v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 12 }
|
|
|
|
tmnxDot1agCfmMipGroupV8v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmSapMipRowStatus,
|
|
tmnxDot1agCfmSapMipSrcMacAddress,
|
|
tmnxDot1agCfmSdpMipRowStatus,
|
|
tmnxDot1agCfmSdpMipSrcMacAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of dot1ag MIP Tables applicable to
|
|
implementing MIPs for SROS release 8.0."
|
|
::= { tmnxDot1agCfmV8v0Groups 1 }
|
|
|
|
tmnxDot1agCfmMepGroupV8v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepFaultPropagation
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for managing dot1ag and Y.1731 tables applicable
|
|
to Virtual MEPs and MEGs on SROS R8.0, and enabling APS support."
|
|
::= { tmnxDot1agCfmV8v0Groups 2 }
|
|
|
|
tmnxDot1agCfmV9v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 13 }
|
|
|
|
tmnxDot1agCfmMaGroupV9v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMaNetHoldDownTimer
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of dot1ag and Y.1731 tables
|
|
applicable to enhancing Maintenance Associations for the SROS release
|
|
9.0."
|
|
::= { tmnxDot1agCfmV9v0Groups 1 }
|
|
|
|
tmnxDot1agCfmMepGroupV9v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepFacilityIfIndex,
|
|
tmnxDot1agCfmMepFacilityVlanId,
|
|
tmnxDot1agCfmMepFacilityType,
|
|
tmnxDot1agCfmMepFcltyFaultNotify,
|
|
tmnxDot1agCfmMepDescription,
|
|
tmnxDot1agCfmMepMcLagInactive
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of dot1ag and Y.1731 tables
|
|
applicable to implementing Facility MEPs for the SROS release 9.0."
|
|
::= { tmnxDot1agCfmV9v0Groups 2 }
|
|
|
|
tmnxDot1agCfmGlobalGroupV9v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMcLagStdbyInactive,
|
|
tmnxDot1agCfmMcLagPropHoldTime
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of global objects for enhancing dot1ag and Y.1731 features
|
|
with support for Multi-Chassis LAG ports for the SROS release 9.0."
|
|
::= { tmnxDot1agCfmV9v0Groups 3 }
|
|
|
|
tmnxDot1agCfmMepSlmGroupV9v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmSLMInactivityTimer,
|
|
tmnxDot1agCfmMepSlmTWTestStatus,
|
|
tmnxDot1agCfmMepSlmTWTestId,
|
|
tmnxDot1agCfmMepSlmTWMacAddress,
|
|
tmnxDot1agCfmMepSlmTWPriority,
|
|
tmnxDot1agCfmMepSlmTWInterval,
|
|
tmnxDot1agCfmMepSlmTWTimeout,
|
|
tmnxDot1agCfmMepSlmTWDataSize,
|
|
tmnxDot1agCfmMepSlmTWSendCount,
|
|
tmnxDot1agCfmMepSlmOWTestStatus,
|
|
tmnxDot1agCfmMepSlmOWTestId,
|
|
tmnxDot1agCfmMepSlmOWMacAddress,
|
|
tmnxDot1agCfmMepSlmOWPriority,
|
|
tmnxDot1agCfmMepSlmOWInterval,
|
|
tmnxDot1agCfmMepSlmOWDataSize,
|
|
tmnxDot1agCfmMepSlmOWSendCount,
|
|
tmnxDot1agCfmMepSlmTestId,
|
|
tmnxDot1agCfmMepSlmRemoteMepId,
|
|
tmnxDot1agCfmMepSlmLastTxSeqF,
|
|
tmnxDot1agCfmMepSlmPacketIn,
|
|
tmnxDot1agCfmMepSlmPacketLossIn,
|
|
tmnxDot1agCfmMepSlmPacketLossOut,
|
|
tmnxDot1agCfmMepSlmPacketUnack
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of Synthetic Loss Measurement
|
|
Tests for the SROS release 9.0."
|
|
::= { tmnxDot1agCfmV9v0Groups 4 }
|
|
|
|
tmnxDot1agCfmMepSlmNotifyGroup NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxDot1agCfmMepSLMTestComplete
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of notification objects for management of dot1ag Synthetic
|
|
Loss Measurement (SLM) test for the SROS release 9.0."
|
|
::= { tmnxDot1agCfmV9v0Groups 5 }
|
|
|
|
tmnxDot1agCfmMepMcastLbmGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepLbmRxIndex
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of multicast loopback tests for
|
|
the SROS release 9.0."
|
|
::= { tmnxDot1agCfmV9v0Groups 6 }
|
|
|
|
tmnxDot1agCfmV10v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 14 }
|
|
|
|
tmnxDot1agCfmMepSlmTWGroupV10v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepSlmTWIntrvlUnits
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects providing additional management options for
|
|
two-way SLM tests in SROS Release 10.0."
|
|
::= { tmnxDot1agCfmV10v0Groups 1 }
|
|
|
|
tmnxDot1agCfmMaGroupV10v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMaMepListMacAddress,
|
|
tmnxDot1agCfmMaNetTotalMEPCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
tables applicable to Maintenance Associations for the SROS release
|
|
10.0."
|
|
::= { tmnxDot1agCfmV10v0Groups 2 }
|
|
|
|
tmnxDot1agCfmMepGroupV10v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepCcmPaddingSize,
|
|
tmnxDot1agCfmMepCcmIgnoreTLVs,
|
|
tmnxDot1agCfmMepAisLowPrioDef
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
tables applicable to MEPs for the SROS release 10.0."
|
|
::= { tmnxDot1agCfmV10v0Groups 3 }
|
|
|
|
tmnxDot1agCfmStatsGroupV10v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmGlobalPacketRxCount,
|
|
tmnxDot1agCfmGlobalPacketTxCount,
|
|
tmnxDot1agCfmGlobalPacketDropped,
|
|
tmnxDot1agCfmGlobalPacketDiscard,
|
|
tmnxDot1agCfmCompName,
|
|
tmnxDot1agCfmCompResourceUsage,
|
|
tmnxDot1agCfmCompResourceLimit
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects reporting dot1ag and Y.1731 global statistics
|
|
applicable for the SROS release 10.0."
|
|
::= { tmnxDot1agCfmV10v0Groups 4 }
|
|
|
|
tmnxDot1agCfmGPGroupV10v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmGraceTxEnable,
|
|
tmnxDot1agCfmGracePeriod,
|
|
tmnxDot1agCfmMepDbGraceRx
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
tables applicable to Continuity Check and the grace period
|
|
notifications."
|
|
::= { tmnxDot1agCfmV10v0Groups 5 }
|
|
|
|
tmnxDot1agCfmV11v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 15 }
|
|
|
|
tmnxDot1agCfmMEPMgmtGroupV11v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepMgmtRowStatus,
|
|
tmnxDot1agCfmMepMgmtType,
|
|
tmnxDot1agCfmMepMgmtServiceId,
|
|
tmnxDot1agCfmMepMgmtIfIndex,
|
|
tmnxDot1agCfmMepMgmtPrimaryVid,
|
|
tmnxDot1agCfmMepMgmtSdpId,
|
|
tmnxDot1agCfmMepMgmtVcId,
|
|
tmnxDot1agCfmMepMgmtFcltyIfIndex,
|
|
tmnxDot1agCfmMepMgmtFcltyVlanId,
|
|
tmnxDot1agCfmMepMgmtDirection,
|
|
tmnxDot1agCfmPVStackMdIndex,
|
|
tmnxDot1agCfmPVStackMaIndex,
|
|
tmnxDot1agCfmPVStackMepId,
|
|
tmnxDot1agCfmPVStackMacAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
tables applicable to the row creation and deletion of MEPs."
|
|
::= { tmnxDot1agCfmV11v0Groups 1 }
|
|
|
|
tmnxDot1agCfmMaGroupV11v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMaCompMipLtrPrio
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
tables applicable to the Maintenance Association (MA)."
|
|
::= { tmnxDot1agCfmV11v0Groups 2 }
|
|
|
|
tmnxDot1agCfmMdGroupV11v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMdCreationOrigin
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
tables applicable to the Maintenance Domain (MD)."
|
|
::= { tmnxDot1agCfmV11v0Groups 3 }
|
|
|
|
tmnxDot1agCfmMepCSFGroupV11v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepCsfEnable,
|
|
tmnxDot1agCfmMepCsfRxMultiplier,
|
|
tmnxDot1agCfmMepCsfRxState,
|
|
tmnxDot1agCfmMepCsfRxInterval,
|
|
tmnxDot1agCfmMepCsfRxCount
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
MEP tables for the purpose of processing CSF (Client Signal Fault)
|
|
frames."
|
|
::= { tmnxDot1agCfmV11v0Groups 4 }
|
|
|
|
tmnxDot1agCfmCSFNotifyGroupV11v0 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxDot1agCfmMepCsfStateChanged
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional notifications for management of dot1ag and
|
|
Y.1731 MEP tables for the purpose of processing CSF (Client Signal
|
|
Fault) frames."
|
|
::= { tmnxDot1agCfmV11v0Groups 5 }
|
|
|
|
tmnxDot1agCfmV12v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 16 }
|
|
|
|
tmnxDot1agCfmMaGroupV12v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMaNetAutoDiscAdmin,
|
|
tmnxDot1agCfmMaMepListAutoDiscvd,
|
|
tmnxDot1agCfmMaNetIdPermission
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
tables applicable to Maintenance Associations for the SROS release
|
|
12.0."
|
|
::= { tmnxDot1agCfmV12v0Groups 1 }
|
|
|
|
tmnxDot1agCfmStatsGroupV12v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmGlobalOpcodeRx,
|
|
tmnxDot1agCfmGlobalOpcodeTx,
|
|
tmnxDot1agCfmGlobalAisTxActive,
|
|
tmnxDot1agCfmGlobalAisTxFail
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects reporting dot1ag and Y.1731 global
|
|
statistics applicable for the SROS release 12.0."
|
|
::= { tmnxDot1agCfmV12v0Groups 2 }
|
|
|
|
tmnxDot1agCfmMepGroupV12v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepOpcodeRx,
|
|
tmnxDot1agCfmMepOpcodeTx,
|
|
tmnxDot1agCfmMepEthAisTxFail,
|
|
tmnxDot1agCfmMepTxLbmTimeout,
|
|
tmnxDot1agCfmMepTxLbmInterval,
|
|
tmnxDot1agCfmMepLbmPaddingSize,
|
|
tmnxDot1agCfmMepIfSupportEnable
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
tables applicable to MEPs for the SROS release 12.0."
|
|
::= { tmnxDot1agCfmV12v0Groups 3 }
|
|
|
|
tmnxDot1agCfmScalarsGroupV12v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmSenderIdType,
|
|
tmnxDot1agCfmSenderIdName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
global configuration for the SROS release 12.0."
|
|
::= { tmnxDot1agCfmV12v0Groups 4 }
|
|
|
|
tmnxDot1agCfmV13v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 17 }
|
|
|
|
tmnxDot1agCfmMepGroupV13v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepCollectLmmStats
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for management of dot1ag and Y.1731
|
|
MEF tables for SROS release 13.0."
|
|
::= { tmnxDot1agCfmV13v0Groups 1 }
|
|
|
|
tmnxDot1agCfmXmppEnhGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepCreationOrigin
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects for XMPP support for fully dynamic
|
|
services for SROS release 13.0R4."
|
|
::= { tmnxDot1agCfmV13v0Groups 2 }
|
|
|
|
tmnxDot1agCfmV14v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 18 }
|
|
|
|
tmnxDot1agCfmDefaultMdGroupV14v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmDfltMdDefMipLtrPrio,
|
|
tmnxDot1agCfmDefaultMdMipLtrPrio
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects maintaining the Default Maintenance
|
|
Domain (MD) on Nokia SROS series systems for Release 14.0."
|
|
::= { tmnxDot1agCfmV14v0Groups 1 }
|
|
|
|
tmnxDot1agNotifyObjsGroupV14v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepFcltyType,
|
|
tmnxDot1agCfmMepFcltyInstance
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects for management of CFM Facility MEP correlation
|
|
log events for the SROS release 14.0."
|
|
::= { tmnxDot1agCfmV14v0Groups 2 }
|
|
|
|
tmnxDot1agCfmCLENotifyGroupV14v0 NOTIFICATION-GROUP
|
|
NOTIFICATIONS {
|
|
tmnxDot1agCfmMepFcltyFaultRaise,
|
|
tmnxDot1agCfmMepFcltyFaultClear
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of notifications for management of the CFM Facility MEP
|
|
correlation log events for the SROS release 14.0."
|
|
::= { tmnxDot1agCfmV14v0Groups 3 }
|
|
|
|
tmnxDot1agCfmV15v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 19 }
|
|
|
|
tmnxDot1agCfmMepGroupV15v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepCcmTxRdi,
|
|
tmnxDot1agCfmMepCcmTxPortStatus,
|
|
tmnxDot1agCfmMepCcmTxIfStatus,
|
|
tmnxDot1agCfmMepTxAis,
|
|
tmnxDot1agCfmMepTxGrace,
|
|
tmnxDot1agCfmMepTxCcm
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of additional objects maintaining the Maintenance
|
|
Association End Point (MEP) capabilities on Nokia SROS series systems
|
|
for Release 15.0."
|
|
::= { tmnxDot1agCfmV15v0Groups 1 }
|
|
|
|
tmnxDot1agCfmTstMepIdGroupV15v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepSlmOWTargetMepId,
|
|
tmnxDot1agCfmMepSlmOWLstDstMac,
|
|
tmnxDot1agCfmMepSlmTWTargetMepId,
|
|
tmnxDot1agCfmMepSlmTWLstDstMac,
|
|
tmnxDot1agCfmMepEthTestTargMepId,
|
|
tmnxDot1agCfmMepEthTestLstDstMac,
|
|
tmnxDot1agCfmMepOWDTTargetMepId,
|
|
tmnxDot1agCfmMepOWDTLstDstMac,
|
|
tmnxDot1agCfmMepTWDTTargetMepId,
|
|
tmnxDot1agCfmMepTWDTLstDstMac,
|
|
tmnxDot1agCfmLearnedRmtMacAddr,
|
|
tmnxDot1agCfmLearnedRmtStaleFlag,
|
|
tmnxDot1agCfmLearnedRmtChngdFlag
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects required to provide additional management options
|
|
to allow CFM testing to remote MepId in SROS Release 15.0."
|
|
::= { tmnxDot1agCfmV15v0Groups 2 }
|
|
|
|
tmnxDot1agCfmLmmPerQosGroupV15v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepCollLmmFcSts,
|
|
tmnxDot1agCfmMepCollLmmFcStsInP
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting the ETH-LMM per QoS Class feature on
|
|
Nokia SROS series systems for Release 15.0."
|
|
::= { tmnxDot1agCfmV15v0Groups 3 }
|
|
|
|
tmnxDot1agCfmMccEdGroupV15v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepTxEthVsmGrace,
|
|
tmnxDot1agCfmMepRxEthVsmGrace,
|
|
tmnxDot1agCfmMepTxEthEd,
|
|
tmnxDot1agCfmMepRxEthEd,
|
|
tmnxDot1agCfmMepEthEdMaxDurRx,
|
|
tmnxDot1agCfmMepEthEdPriority,
|
|
tmnxDot1agCfmMepDbMccEdRx,
|
|
tmnxDot1agCfmMepOpRxPeerGrace
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting the ETH-MCC Ethernet Defect (ED)
|
|
feature on Nokia SROS series systems for Release 15.0."
|
|
::= { tmnxDot1agCfmV15v0Groups 4 }
|
|
|
|
tmnxDot1agCfmSdpPrimVLanGrpV15v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmSdpPVStackMdIndex,
|
|
tmnxDot1agCfmSdpPVStackMaIndex,
|
|
tmnxDot1agCfmSdpPVStackMepId,
|
|
tmnxDot1agCfmSdpPVStackMacAddr
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting Primary VLANs on SDP bindings on Nokia
|
|
SROS series systems for Release 15.0."
|
|
::= { tmnxDot1agCfmV15v0Groups 5 }
|
|
|
|
tmnxDot1agCfmLbmLbrMepGroupV15v0 OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepLbmSvcActResp
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting LBM and LBR MEP Processing on the IOM
|
|
on Nokia SROS series systems for Release 15.0."
|
|
::= { tmnxDot1agCfmV15v0Groups 6 }
|
|
|
|
tmnxDot1agCfmAdminNameGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMdAdminName,
|
|
tmnxDot1agCfmMaNetAdminName,
|
|
tmnxDot1agCfmMdMgmtRowStatus,
|
|
tmnxDot1agCfmMdMgmtName,
|
|
tmnxDot1agCfmMdMgmtFormat,
|
|
tmnxDot1agCfmMdMgmtMdLevel,
|
|
tmnxDot1agCfmMdMgmtAdminName,
|
|
tmnxDot1agCfmMaMgmtRowStatus,
|
|
tmnxDot1agCfmMaMgmtFormat,
|
|
tmnxDot1agCfmMaMgmtName,
|
|
tmnxDot1agCfmMaMgmtCcmInterval,
|
|
tmnxDot1agCfmMaMgmtAdminName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting the addition of an admin name on Nokia
|
|
SROS series systems for Release 15.1."
|
|
::= { tmnxDot1agCfmV15v0Groups 7 }
|
|
|
|
tmnxDot1agCfmV16v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 20 }
|
|
|
|
tmnxDot1agCfmEthBnGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepEthBnReceive,
|
|
tmnxDot1agCfmMepEthBnRxUpdPacing,
|
|
tmnxDot1agCfmMepEthBnNominalBw,
|
|
tmnxDot1agCfmMepEthBnCurrentBw,
|
|
tmnxDot1agCfmMepEthBnReportedBw,
|
|
tmnxDot1agCfmMepEthBnLastReport,
|
|
tmnxDot1agCfmMepEthBnUpdPacTimer,
|
|
tmnxDot1agCfmMepEthBnPortId,
|
|
tmnxDot1agCfmMepEthBnRxInterval
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting the processing of Eth-BN messages on
|
|
Nokia SROS series systems in release 16.0."
|
|
::= { tmnxDot1agCfmV16v0Groups 1 }
|
|
|
|
tmnxDot1agCfmMaBrNameGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMaBrNamePVlanId,
|
|
tmnxDot1agCfmMaBrNameMhfCreation,
|
|
tmnxDot1agCfmMaBrNameIdPerm,
|
|
tmnxDot1agCfmMaBrNameMipLtrPrio,
|
|
tmnxDot1agCfmMaBrNameNumOfVids,
|
|
tmnxDot1agCfmMaBrNameRowStatus
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects supporting the addition of a configurable bridge
|
|
name on Nokia SROS series systems in release 16.0."
|
|
::= { tmnxDot1agCfmV16v0Groups 2 }
|
|
|
|
tmnxDot1agCfmAdminNameGroupExt OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMaMgmtHoldDownTimer,
|
|
tmnxDot1agCfmMaMgmtAutoDiscAdmin,
|
|
tmnxDot1agCfmMaMgmtIdPermission
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects added for additional support of admin name
|
|
management on Nokia SROS series systems for Release 16.0."
|
|
::= { tmnxDot1agCfmV16v0Groups 3 }
|
|
|
|
tmnxDot1agCfmModelDrivenGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agAutoMdIndexRangeStart,
|
|
tmnxDot1agAutoMdIndexRangeEnd,
|
|
tmnxDot1agAutoMaIndexRangeStart,
|
|
tmnxDot1agAutoMaIndexRangeEnd
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects added to support model driven mode on Nokia SROS
|
|
series systems in release 16.0."
|
|
::= { tmnxDot1agCfmV16v0Groups 4 }
|
|
|
|
tmnxDot1agCfmV19v0Groups OBJECT IDENTIFIER ::= { tmnxDot1agCfmGroups 21 }
|
|
|
|
tmnxDot1agCfmMepIXRGroup OBJECT-GROUP
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepInstallMep
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The group of objects added to support MEP forwarding plane
|
|
installation on Nokia SROS series systems in release 19.5."
|
|
::= { tmnxDot1agCfmV19v0Groups 1 }
|
|
|
|
tmnxDot1agNotificationsPrefix OBJECT IDENTIFIER ::= { tmnxSRNotifyPrefix 52 }
|
|
|
|
tmnxDot1agNotifications OBJECT IDENTIFIER ::= { tmnxDot1agNotificationsPrefix 0 }
|
|
|
|
tmnxDot1agCfmMepLbmTestComplete NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
dot1agCfmMepTransmitLbmDestMacAddress
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepLbmTestComplete notification indicates that a
|
|
loopback test has been issued and results are ready."
|
|
::= { tmnxDot1agNotifications 1 }
|
|
|
|
tmnxDot1agCfmMepLtmTestComplete NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
dot1agCfmMepTransmitLtmSeqNumber
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepLtmTestComplete notification indicates that a
|
|
linktrace test has been issued and results are ready. The
|
|
dot1agCfmMepTransmitLtmSeqNumber indicates the Transaction Identifier
|
|
to use to retrieve the Link-trace results."
|
|
::= { tmnxDot1agNotifications 2 }
|
|
|
|
tmnxDot1agCfmMepEthTestComplete NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepCurrByteCount,
|
|
tmnxDot1agCfmMepCurrFailedBits,
|
|
tmnxDot1agCfmMepCurrCrcFailures
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepEthTestComplete notification indicates that an
|
|
eth-test has been issued and results are ready. The
|
|
tmnxDot1agCfmMepCurrByteCount indicates the number of bytes contained
|
|
in the frame's Test TLV, and the tmnxDot1agCfmMepCurrFailedBits and
|
|
tmnxDot1agCfmMepCurrCrcFailures indicate the failure state of the
|
|
test. A value of Zero (0) for tmnxDot1agCfmMepCurrFailedBits and a
|
|
value of 'false (2)' for tmnxDot1agCfmMepCurrCrcFailures indicates a
|
|
successful test."
|
|
::= { tmnxDot1agNotifications 3 }
|
|
|
|
tmnxDot1agCfmMepDMTestComplete NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepDelayTestDelay
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepDMTestComplete notification indicates that a
|
|
One-Way-Delay-Test (OWDT) frame, or a Two-Way-Delay-Test (TWDT)
|
|
response was received. For an OWDT frame, traps are raised only when a
|
|
delay threshold of three seconds is exceeded."
|
|
::= { tmnxDot1agNotifications 4 }
|
|
|
|
tmnxDot1agCfmMepAisStateChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepEthRxAis
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepAisStateChanged notification is generated when a
|
|
MEP enters or exits an AIS state."
|
|
::= { tmnxDot1agNotifications 5 }
|
|
|
|
tmnxDot1agCfmMipEvaluation NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxDot1agCfmNotifySvcId
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMipEvaluation notification is generated when a
|
|
virtual MEP is created or deleted causing MIP reevaluation on the
|
|
service. On virtual MEP creation, any MIPs in the service will be
|
|
removed. On virtual MEP deletion, the MIPs are reevaluated."
|
|
::= { tmnxDot1agNotifications 6 }
|
|
|
|
tmnxDot1agCfmMepSLMTestComplete NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepSlmTestId,
|
|
tmnxDot1agCfmMepSlmRemoteMepId,
|
|
tmnxDot1agCfmMepSlmLastTxSeqF,
|
|
tmnxDot1agCfmMepSlmPacketIn,
|
|
tmnxDot1agCfmMepSlmPacketLossIn,
|
|
tmnxDot1agCfmMepSlmPacketLossOut,
|
|
tmnxDot1agCfmMepSlmPacketUnack
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepSLMTestComplete notification is generated when a
|
|
two-way Synthetic Loss Measurement (SLM) test is completed."
|
|
::= { tmnxDot1agNotifications 7 }
|
|
|
|
tmnxDot1agCfmMepCsfStateChanged NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepCsfRxState
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"The tmnxDot1agCfmMepCsfStateChanged notification is generated when a
|
|
MEP enters or exits a CSF state."
|
|
::= { tmnxDot1agNotifications 8 }
|
|
|
|
tmnxDot1agCfmMepFcltyFaultRaise NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepFcltyType,
|
|
tmnxDot1agCfmMepFcltyInstance
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxDot1agCfmMepFcltyFaultRaise notification is generated
|
|
when the associated facility MEP dot1agCfmMepHighestPrDefect has
|
|
increased.
|
|
|
|
[EFFECT] This notification can be used to correlate the ETH_CFM
|
|
dot1agCfmFaultAlarm event and the related IF-MIB::linkDown
|
|
notification caused by the failure of the facility MEP.
|
|
|
|
[RECOVERY] Follow the recovery for the dot1agCfmFaultAlarm and the
|
|
related IF-MIB::linkDown caused by the failure of the facility MEP."
|
|
::= { tmnxDot1agNotifications 9 }
|
|
|
|
tmnxDot1agCfmMepFcltyFaultClear NOTIFICATION-TYPE
|
|
OBJECTS {
|
|
tmnxDot1agCfmMepFcltyType,
|
|
tmnxDot1agCfmMepFcltyInstance
|
|
}
|
|
STATUS current
|
|
DESCRIPTION
|
|
"[CAUSE] The tmnxDot1agCfmMepFcltyFaultClear notification is generated
|
|
when the associated facility MEP has cleared an event affecting the
|
|
specific tmnxDot1agCfmMepFcltyType tmnxDot1agCfmMepFcltyInstance
|
|
combination over which it is configured.
|
|
|
|
[EFFECT] This notification can be used to correlate the ETH_CFM
|
|
dot1agCfmFaultAlarm event and the related IF-MIB::linkUp notification
|
|
caused by the facility MEP."
|
|
::= { tmnxDot1agNotifications 10 }
|
|
|
|
END
|