NEWTEC-MORFBUC-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-IDENTITY,
OBJECT-TYPE
FROM SNMPv2-SMI
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
NtcAlarmState
FROM NEWTEC-TC-MIB
ntcFunction
FROM NEWTEC-MAIN-MIB;
--
-- Module Identification
--
ntcMoRfBlockUpConv MODULE-IDENTITY
LAST-UPDATED "201605170900Z"
ORGANIZATION "Newtec Cy"
CONTACT-INFO
"Newtec Cy
Postal: Newtec Cy
Laarstraat 5
B-9100 Sint-Niklaas
Belgium
Tel: +32 3 780 65 00
Fax: +32 3 780 65 49
Web: www.newtec.be
E-mail: techsupport@newtec.be"
DESCRIPTION
"Newtec modular RF block upconvertor MIB containing definitions for the
convertor functionality."
REVISION "201605170900Z"
DESCRIPTION
"Initial release for M6100 R2.8"
::= { ntcFunction 10000 }
--
-- Top-Level Structure
--
-- ntcMoRfBlockUpConv content
ntcMoRfBucObjects OBJECT-IDENTITY
STATUS current
DESCRIPTION "Container holding ntcMoRfBucObjects definitions."
::= { ntcMoRfBlockUpConv 1 }
ntcMoRfBucConformance OBJECT-IDENTITY
STATUS current
DESCRIPTION "Conformance requirements."
::= { ntcMoRfBlockUpConv 2 }
-- ntcMoRfBucObjects content
ntcMoRfBucAlarm OBJECT-IDENTITY
STATUS current
DESCRIPTION "Container holding ntcMoRfBucAlarm definitions."
::= { ntcMoRfBucObjects 1 }
-- ntcMoRfBucConformance content
ntcMoRfBucConfCompliance OBJECT-IDENTITY
STATUS current
DESCRIPTION "Device compliance statements."
::= { ntcMoRfBucConformance 1 }
ntcMoRfBucConfGroup OBJECT-IDENTITY
STATUS current
DESCRIPTION "Groups used by device compliance statements."
::= { ntcMoRfBucConformance 2 }
--
-- Managed Objects
--
ntcMoRfBucHardware OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm is raised when the converter is not working correctly due to
hardware failures on the converter module This variable indicates the current
status of the alarm."
::= { ntcMoRfBucAlarm 1 }
ntcMoRfBucCommunication OBJECT-TYPE
SYNTAX NtcAlarmState
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This alarm is raised when the converter is not working correctly due to
communication failures on the converter module This variable indicates the
current status of the alarm."
::= { ntcMoRfBucAlarm 2 }
--
-- Module Conformance
--
ntcMoRfBucConfGrpV1Standard OBJECT-GROUP
OBJECTS {
ntcMoRfBucHardware,
ntcMoRfBucCommunication
}
STATUS current
DESCRIPTION
"Managed objects that constitute version 1 of a system device with standard capabilities."
::= { ntcMoRfBucConfGroup 1}
ntcMoRfBucConfCompV1Standard MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Compliance statement for Newtec device MIB implementations."
MODULE -- this module
MANDATORY-GROUPS
{
ntcMoRfBucConfGrpV1Standard
}
::= { ntcMoRfBucConfCompliance 1 }
END