656 lines
28 KiB
Plaintext
656 lines
28 KiB
Plaintext
AFFIRMED-TEMS-NOTIFICATION-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
|
|
MODULE-IDENTITY, NOTIFICATION-TYPE, IpAddress FROM SNMPv2-SMI
|
|
TEXTUAL-CONVENTION,DisplayString, TruthValue,DateAndTime FROM SNMPv2-TC
|
|
AlarmLevel, AlarmLevelString FROM AFFIRMED-TEMS-TC-MIB
|
|
affirmedSnmpNotifications FROM AFFIRMED-TEMS-SNMP-MIB
|
|
temsServerPerfMetric, temsServerPerfMetricCollectedValue,
|
|
perfMetricCriticalThreshold, perfMetricMajorThreshold,
|
|
perfMetricMinorThreshold, perfMetricClearThreshold FROM AFFIRMED-TEMS-OBJECTS-MIB;
|
|
|
|
affirmedTemsNotifications MODULE-IDENTITY
|
|
LAST-UPDATED "201504091104Z"
|
|
ORGANIZATION "Affirmed Networks"
|
|
CONTACT-INFO "affirmed@affirmednetworks.com"
|
|
DESCRIPTION "Management Information for notification/alarming the NB NMS / OSS Systems."
|
|
REVISION "201504091104Z"
|
|
DESCRIPTION "NorthBound Notification MIB for ANMS Release"
|
|
::= { affirmedSnmpNotifications 1 }
|
|
|
|
--
|
|
-- Notification Config
|
|
--
|
|
notificationConfig OBJECT IDENTIFIER ::= { affirmedTemsNotifications 1 }
|
|
|
|
suppressAlarms OBJECT-TYPE
|
|
SYNTAX TruthValue
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION "This is used to request the EMS Server to stop sending alarms to All the Managers."
|
|
DEFVAL { false }
|
|
::= { notificationConfig 1}
|
|
|
|
--
|
|
-- Fault and Alarm object define
|
|
--
|
|
notificationObjects OBJECT IDENTIFIER ::= { affirmedTemsNotifications 2 }
|
|
|
|
temsServerTimeStamp OBJECT-TYPE
|
|
SYNTAX DateAndTime
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This object specifies Time at which the Alarm is triggered by the Mgmt Server"
|
|
::= { notificationObjects 1 }
|
|
|
|
alarmSeverity OBJECT-TYPE
|
|
SYNTAX AlarmLevelString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This object indicates the severity of alarm. Clear severity will be used
|
|
to clear the previously raised alarm"
|
|
::= { notificationObjects 2 }
|
|
|
|
alarmDiagnosticData OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This is used as a place holder to include detailed alarm message"
|
|
::= { notificationObjects 3 }
|
|
|
|
networkElementIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This is used to indicate the IP-Address of the Network Element serving
|
|
as the root cause of the problem. However, if the trap is generated by the Mgmt Server
|
|
itself, this may contain the IP-Address of the Mgmt Server."
|
|
::= { notificationObjects 4 }
|
|
|
|
networkElementSoftwareVersion OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Indicates the current software version of the Network Element being Managed"
|
|
::= { notificationObjects 5 }
|
|
|
|
cliUserName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Indicates the User Name used to open the CLI Session with the Network Element"
|
|
::= { notificationObjects 6 }
|
|
|
|
notificationAddress OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Indicates the E-Mail Address used for Notification"
|
|
::= { notificationObjects 7 }
|
|
|
|
sourceComponent OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Indicates the Component within the Router / Switch responsible for the problem. It is represented in Shelf-Slot-Port format"
|
|
::= { notificationObjects 8 }
|
|
|
|
alarmCategory OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Category Assigned for the Alarm. Used as a place holder to differentiate different types of
|
|
Traps that can be raised from the same component of the equipment"
|
|
::= { notificationObjects 9 }
|
|
|
|
emsNodeIPAddress OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This is used to indicate the IP-Address of the EMS node for
|
|
EMS cluster state change notifications."
|
|
::= { notificationObjects 10 }
|
|
|
|
emsClusterChangeNotificationData OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Includes information about the current state of the EMS cluster.
|
|
This is included with the EMS cluster state change notifications."
|
|
::= { notificationObjects 11 }
|
|
|
|
vCenterOldStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This is used by vcenter to indicate the old status in the notification.Sample Values: Gray/Yellow"
|
|
::= { notificationObjects 12 }
|
|
|
|
vCenterNewStatus OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This is used by vcenter to indicate the new status in the notification.Sample Values: Gray/Yellow"
|
|
::= { notificationObjects 13 }
|
|
|
|
vCenterTargetObjectType OBJECT-TYPE
|
|
SYNTAX INTEGER { unknown(1), host(2), vm(3), other(4)}
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "This is the alarm target object type"
|
|
::= { notificationObjects 14 }
|
|
|
|
alarmRemedy OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "It is used to indicate the potential impact of the alarm and corrective action to remedy."
|
|
::= { notificationObjects 15 }
|
|
|
|
alarmAdditionalInfo OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "It contain semi-colon separated name/value pairs additional information."
|
|
::= { notificationObjects 16 }
|
|
|
|
alarmTrapOID OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "It is used to indicate Trap OID information."
|
|
::= { notificationObjects 17 }
|
|
|
|
elementHostName OBJECT-TYPE
|
|
SYNTAX DisplayString
|
|
MAX-ACCESS accessible-for-notify
|
|
STATUS current
|
|
DESCRIPTION "Includes information about the host name of the element."
|
|
::= { notificationObjects 18 }
|
|
|
|
temsNorthBoundNotifications OBJECT IDENTIFIER ::= { affirmedTemsNotifications 3 }
|
|
|
|
networkElementNotReachable NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever
|
|
a managed network element turns unreachable (ICMP)."
|
|
::= { temsNorthBoundNotifications 1 }
|
|
|
|
networkElementNotManageable NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever
|
|
a managed network element is reachable via ICMP but not reachable via the Management protocol (SNMP / TL1 )"
|
|
::= { temsNorthBoundNotifications 2 }
|
|
|
|
networkElementManageable NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to clear the
|
|
not manageable events raised previously."
|
|
::= { temsNorthBoundNotifications 3 }
|
|
|
|
unSupportedNetworkElementVersion NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
networkElementSoftwareVersion,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
|
|
encounters / discovers a Network element running an Unsupported software version."
|
|
::= { temsNorthBoundNotifications 4 }
|
|
|
|
cliLoginFailed NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
cliUserName,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
|
|
could not login to the CLI (or TL1) session of the Network Element using the supplied
|
|
Credentials"
|
|
::= { temsNorthBoundNotifications 5 }
|
|
|
|
alarmEmailNotificationFailure NOTIFICATION-TYPE
|
|
OBJECTS { notificationAddress,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) upon its
|
|
Failure to send the E-Mail Notification to NB Clients registered for E-Mail Notification"
|
|
::= { temsNorthBoundNotifications 6 }
|
|
|
|
dataCollectionFailure NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
temsServerPerfMetric,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Indicates a Failure during Data Collection.
|
|
NB managers can either ignore it (or) log-it."
|
|
::= { temsNorthBoundNotifications 7 }
|
|
|
|
temsServerPerfMetricCriticalTCA NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
temsServerPerfMetric,
|
|
temsServerPerfMetricCollectedValue,
|
|
perfMetricCriticalThreshold,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to report
|
|
a Critical Threshold Crossing Alert, whenever the Critical Threshold limit is
|
|
crossed for the current Performance Metric"
|
|
::= { temsNorthBoundNotifications 8 }
|
|
|
|
temsServerPerfMetricMajorTCA NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
temsServerPerfMetric,
|
|
temsServerPerfMetricCollectedValue,
|
|
perfMetricMajorThreshold,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to report
|
|
a Major Threshold Crossing Alert, whenever the Major Threshold limit is
|
|
crossed for the current Performance Metric"
|
|
::= { temsNorthBoundNotifications 9 }
|
|
|
|
temsServerPerfMetricMinorTCA NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
temsServerPerfMetric,
|
|
temsServerPerfMetricCollectedValue,
|
|
perfMetricMinorThreshold,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to report
|
|
a Minor Threshold Crossing Alert, whenever the Minor Threshold limit is
|
|
crossed for the current Performance Metric"
|
|
::= { temsNorthBoundNotifications 10 }
|
|
|
|
temsServerPerfMetricClearTCA NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
temsServerPerfMetric,
|
|
temsServerPerfMetricCollectedValue,
|
|
perfMetricClearThreshold,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to Clear
|
|
the previously raised Critical / Major / Minor TCA for this Performance Metric."
|
|
::= { temsNorthBoundNotifications 11 }
|
|
|
|
alarmFromNetworkElement NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
sourceComponent,
|
|
alarmCategory,
|
|
alarmSeverity,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmRemedy,
|
|
alarmAdditionalInfo,
|
|
alarmTrapOID,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to report
|
|
an Alarm Raised due to the occurrence of a trap from the Network Element.
|
|
Severity List includes Cleared. the Clear Alarm should clear the previous raise Alarm.
|
|
The combination of networkElementIPAddress, sourceComponent (if any), alarmCategory (if available)
|
|
and alarmSeverity shall be used to uniquely identify a specific root cause"
|
|
::= { temsNorthBoundNotifications 12 }
|
|
|
|
hotStandbyTakesOver NOTIFICATION-TYPE
|
|
OBJECTS { alarmDiagnosticData,
|
|
temsServerTimeStamp
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION "Indicates a Switchover of the Management server from primary to Standby Server.
|
|
Note: This alarm will be triggered only when the Management Server is deployed in a Primary - HotStandBy mode."
|
|
::= { temsNorthBoundNotifications 13 }
|
|
|
|
primaryServerisRestored NOTIFICATION-TYPE
|
|
OBJECTS { alarmDiagnosticData,
|
|
temsServerTimeStamp
|
|
}
|
|
STATUS deprecated
|
|
DESCRIPTION "Indicates that the Primary Management Server has been restored back in Service.
|
|
Note: This alarm will be triggered only when the Management Server is deployed in a Primary - HotStandBy mode."
|
|
::= { temsNorthBoundNotifications 14 }
|
|
|
|
alarmfromElementManagementSystem NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
sourceComponent,
|
|
alarmCategory,
|
|
alarmSeverity,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to report
|
|
an Alarm Raised due to the occurence of a trap from the Network Management System.
|
|
Severity List includes Cleared. the Clear Alarm should clear the previous raise Alarm.
|
|
The combination of networkElementIPAddress, sourceComponent (if any), alarmCategory (if available)
|
|
and alarmSeverity shall be used to uniquely identify a specific root cause"
|
|
::= { temsNorthBoundNotifications 15 }
|
|
|
|
|
|
geoRedundancyGroupMismatch NOTIFICATION-TYPE
|
|
OBJECTS { sourceComponent,
|
|
networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
alarmSeverity,
|
|
temsServerTimeStamp,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management server will send this notification to its NB clients (NMS / OSS) when it detects
|
|
mismatch information from EMS, active and standby network element
|
|
The networkElementIpAddress attribute is populated with the Mgmt Server IP address"
|
|
::= { temsNorthBoundNotifications 16 }
|
|
|
|
|
|
|
|
|
|
vnfScaleKpiMonitorAlarm NOTIFICATION-TYPE
|
|
OBJECTS { sourceComponent,
|
|
networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
alarmSeverity,
|
|
temsServerTimeStamp,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Dynamic VM capacity management KPI monitoring alarms.
|
|
Source is cluster[vclusterId]/<KPIName> where KPIName can be
|
|
DCMSession, WSMSession, ASMConn, ASMThruput.
|
|
Severity may be of one of the three values: MAJOR, CRITICAL, CLEARED
|
|
MAJOR The respective KPI is transitioned to one of the following states:
|
|
Underload threshold crossed for 80% of the duration or
|
|
Overload threshold crossed for 80% of the duration
|
|
CRITICAL The respective KPI is transitioned to one of the following states:
|
|
Underload condition
|
|
Overload condition
|
|
CLEARED The respective KPI is transitioned to one of the following states:
|
|
Normal condition, i.e. in neither underload nor overload condition
|
|
The networkElementIpAddress attribute is populated with the Mgmt Server IP address"
|
|
::= { temsNorthBoundNotifications 17 }
|
|
|
|
|
|
vnfScaleOutAlarm NOTIFICATION-TYPE
|
|
OBJECTS { sourceComponent,
|
|
networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
alarmSeverity,
|
|
temsServerTimeStamp,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Generated when VM scale out operation fails
|
|
Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL.
|
|
The networkElementIpAddress attribute is populated with the Mgmt Server IP address"
|
|
::= { temsNorthBoundNotifications 18 }
|
|
|
|
vnfScaleInAlarm NOTIFICATION-TYPE
|
|
OBJECTS { sourceComponent,
|
|
networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
alarmSeverity,
|
|
temsServerTimeStamp,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Generated when VM scale in operation fails
|
|
Source is cluster[vclusterId]/node[vnodeId]. Severity will be CRITICAL.
|
|
The networkElementIpAddress attribute is populated with the Mgmt Server IP address"
|
|
::= { temsNorthBoundNotifications 19 }
|
|
|
|
|
|
emsClusterStatusChangeNotification NOTIFICATION-TYPE
|
|
OBJECTS { emsNodeIPAddress,
|
|
emsClusterChangeNotificationData,
|
|
alarmSeverity,
|
|
temsServerTimeStamp,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) upon its
|
|
detection of cluster status change"
|
|
::= { temsNorthBoundNotifications 20 }
|
|
|
|
|
|
alarmFromVCenter NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmCategory,
|
|
vCenterTargetObjectType,
|
|
vCenterOldStatus,
|
|
vCenterNewStatus,
|
|
alarmDiagnosticData,
|
|
sourceComponent,
|
|
temsServerTimeStamp,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to report
|
|
an Alarm Raised due to the occurence of a trap from VCenter Server"
|
|
::= { temsNorthBoundNotifications 21 }
|
|
|
|
cliLoginSuccess NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
cliUserName,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever it
|
|
could be login to the CLI (or TL1) session of the Network Element using the supplied
|
|
Credentials"
|
|
::= { temsNorthBoundNotifications 22 }
|
|
|
|
cliTemplateConfigFailed NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
sourceComponent,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever
|
|
cli template configuration failed."
|
|
::= { temsNorthBoundNotifications 23 }
|
|
|
|
cliTemplateConfigSuccess NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
sourceComponent,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever
|
|
cli template configuration succeeds."
|
|
::= { temsNorthBoundNotifications 24 }
|
|
|
|
alarmtriggeredCliTemplateConfigFailed NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
sourceComponent,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever
|
|
alarm triggered cli template configuration failed."
|
|
::= { temsNorthBoundNotifications 25 }
|
|
|
|
alarmtriggeredCliTemplateConfigSuccess NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
sourceComponent,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) whenever
|
|
alarm triggered cli template configuration succeeds."
|
|
::= { temsNorthBoundNotifications 26 }
|
|
|
|
alarmSnmpNotificationFailure NOTIFICATION-TYPE
|
|
OBJECTS { sourceComponent,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) upon its
|
|
Failure to forward the trap to NB Clients registered for Trap Forwarding."
|
|
::= { temsNorthBoundNotifications 27 }
|
|
|
|
masterSlaveStandbyNodeDown NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to reports that
|
|
in cluster topology standby node moved to down state."
|
|
::= { temsNorthBoundNotifications 28 }
|
|
|
|
masterSlaveStandbyNodeUp NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmSeverity,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its NB Clients (NMS / OSS) to reports that
|
|
in cluster topology standby node moved to up state."
|
|
::= { temsNorthBoundNotifications 29 }
|
|
|
|
NBHeartBeat NOTIFICATION-TYPE
|
|
OBJECTS {}
|
|
STATUS current
|
|
DESCRIPTION "Management Server will send this notification to its INFORM supported NB Clients to verify
|
|
the NB client alive status."
|
|
::= { temsNorthBoundNotifications 31 }
|
|
|
|
|
|
networkElementAutoUnmanage NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmCategory,
|
|
alarmSeverity,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
alarmRemedy,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Device has been automatically unmanaged due to authentication failure."
|
|
::= { temsNorthBoundNotifications 32 }
|
|
|
|
networkElementManage NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmCategory,
|
|
alarmSeverity,
|
|
alarmDiagnosticData,
|
|
temsServerTimeStamp,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "Device has been managed successfully."
|
|
::= { temsNorthBoundNotifications 33 }
|
|
|
|
CUPSConfigurationMismatch NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmSource,
|
|
alarmCategory,
|
|
alarmSeverity,
|
|
alarmMessage,
|
|
alarmUpdatedTime,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "CUPS Configuration mismatch found."
|
|
::= { temsNorthBoundNotifications 34 }
|
|
|
|
CUPSConfigurationMatch NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmSource,
|
|
alarmCategory,
|
|
alarmSeverity,
|
|
alarmMessage,
|
|
alarmClearedTime,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "CUPS Configuration mismatch cleared."
|
|
::= { temsNorthBoundNotifications 35 }
|
|
|
|
CUPSGroupCreationFailed NOTIFICATION-TYPE
|
|
OBJECTS { networkElementIPAddress,
|
|
alarmSource,
|
|
alarmCategory,
|
|
alarmSeverity,
|
|
alarmMessage,
|
|
alarmUpdatedTime,
|
|
elementHostName
|
|
}
|
|
STATUS current
|
|
DESCRIPTION "CUPS Group Creation Failed. Manually remove the config from CPlane."
|
|
::= { temsNorthBoundNotifications 36 }
|
|
|
|
END
|