Observium_CE/mibs/mellanox/MELLANOX-POWER-CYCLE-MIB

78 lines
2.0 KiB
Plaintext

MELLANOX-POWER-CYCLE-MIB DEFINITIONS ::= BEGIN
IMPORTS
NOTIFICATION-TYPE, MODULE-IDENTITY, OBJECT-TYPE, Integer32
FROM SNMPv2-SMI
mellanoxPowerCycle
FROM MELLANOX-SMI-MIB;
-- Mellanox Power Cycle MIB
mellanoxPowerCycleMib MODULE-IDENTITY
LAST-UPDATED "201806040000Z"
ORGANIZATION
"Mellanox Technologies, Inc."
CONTACT-INFO
"
Mellanox Technologies, Inc.
350 Oakmead Parkway, Suite 100
Sunnyvale, CA 94085
Tel: 408-970-3400
Fax: 408-970-3403
E-mail: info@mellanox.com
"
DESCRIPTION
"Mellanox PowerCycle MIB"
REVISION "201806040000Z"
DESCRIPTION
"Added planned reload traps"
::= { mellanoxPowerCycle 1 }
mellanoxPowerCycleMibObjects OBJECT IDENTIFIER ::= { mellanoxPowerCycleMib 1 }
mellanoxPowerCycleCmd OBJECT IDENTIFIER ::= { mellanoxPowerCycleMibObjects 2 }
mellanoxPowerCycleNotifications OBJECT IDENTIFIER ::= { mellanoxPowerCycleMibObjects 3 }
mellanoxPowerCycleCmdExecute OBJECT-TYPE
SYNTAX INTEGER {
mellanoxPowerCycleCmdExecuteReload (1),
mellanoxPowerCycleCmdExecuteReloadDiscard (2),
mellanoxPowerCycleCmdExecuteReloadForce (3),
mellanoxPowerCycleCmdExecuteReloadSlave (4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The operation to execute
Setting this value will initiate the operation"
::= { mellanoxPowerCycleCmd 1 }
mellanoxPowerCycleCmdStatus OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The status of the operation:
0: No operation
1-100: progress percentage
101: success
>200: failure"
::= { mellanoxPowerCycleCmd 2 }
mellanoxPowerCycleCmdStatusString OBJECT-TYPE
SYNTAX OCTET STRING
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"String value describing the operation status or error"
::= { mellanoxPowerCycleCmd 3 }
mellanoxPowerCyclePlannedReload NOTIFICATION-TYPE
STATUS current
DESCRIPTION
"Device has resumed after a planned reload operation"
::= { mellanoxPowerCycleNotifications 1 }
END