1038 lines
31 KiB
Plaintext
1038 lines
31 KiB
Plaintext
-- ****************************************************************************
|
|
-- ****************************************************************************
|
|
-- Copyright(c) 2004 Mediatrix Telecom, Inc.
|
|
-- NOTICE:
|
|
-- This document contains information that is confidential and proprietary
|
|
-- to Mediatrix Telecom, Inc.
|
|
-- Mediatrix Telecom, Inc. reserves all rights to this document as well as
|
|
-- to the Intellectual Property of the document and the technology and
|
|
-- know-how that it includes and represents.
|
|
-- This publication cannot be reproduced, neither in whole nor in part in
|
|
-- any form whatsoever without written prior approval by
|
|
-- Mediatrix Telecom, Inc.
|
|
-- Mediatrix Telecom, Inc. reserves the right to revise this publication
|
|
-- and make changes at any time and without the obligation to notify any
|
|
-- person and/or entity of such revisions and/or changes.
|
|
-- ****************************************************************************
|
|
-- ****************************************************************************
|
|
|
|
MX-HARDWARE-MIB
|
|
DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
MODULE-IDENTITY,
|
|
OBJECT-TYPE,
|
|
Unsigned32,
|
|
Integer32
|
|
FROM SNMPv2-SMI
|
|
MODULE-COMPLIANCE,
|
|
OBJECT-GROUP
|
|
FROM SNMPv2-CONF
|
|
MxEnableState,
|
|
MxActivationState,
|
|
MxIpHostName,
|
|
MxIpAddress,
|
|
MxIpPort,
|
|
MxAdvancedIpPort,
|
|
MxIpSubnetMask,
|
|
MxDigitMap
|
|
FROM MX-TC
|
|
MxUInt64,
|
|
MxFloat32,
|
|
MxIpHostNamePort,
|
|
MxIpAddr,
|
|
MxIpAddrPort,
|
|
MxIpAddrMask,
|
|
MxUri,
|
|
MxUrl
|
|
FROM MX-TC2
|
|
mediatrixHardware
|
|
FROM MX-SMI2;
|
|
|
|
hardwareMIB MODULE-IDENTITY
|
|
LAST-UPDATED "1910210000Z"
|
|
ORGANIZATION " Mediatrix Telecom, Inc. "
|
|
CONTACT-INFO " Mediatrix Telecom, Inc.
|
|
4229, Garlock Street
|
|
Sherbrooke (Quebec)
|
|
Canada
|
|
Phone: (819) 829-8749
|
|
"
|
|
DESCRIPTION " Hardware
|
|
|
|
The Hardware component manages the mainboard and the extension
|
|
cards.
|
|
"
|
|
::= { mediatrixHardware 40000 }
|
|
|
|
hardwareMIBObjects OBJECT IDENTIFIER ::= { hardwareMIB 1 }
|
|
|
|
-- Scalar:Reset/Default Button Management
|
|
|
|
resetButtonManagement OBJECT-TYPE
|
|
SYNTAX INTEGER { all(100) , disablePartialReset(200) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Reset/Default Button Management
|
|
|
|
Configures the actions allowed on the reset/default button.
|
|
|
|
* All: All the actions are allowed: reset, partial reset, and
|
|
factory reset.
|
|
* DisablePartialReset: All actions are allowed except the
|
|
partial reset.
|
|
|
|
The reset action restarts the unit.
|
|
|
|
The partial reset action provides a way to contact the unit in a
|
|
known and static state while keeping most of the configuration
|
|
unchanged.
|
|
|
|
The factory reset action reverts the unit back to its default
|
|
factory settings.
|
|
|
|
For more details, search for the Partial Reset documentation in
|
|
the Media5 Documentation Portal (https://
|
|
documentation.media5corp.com).
|
|
|
|
"
|
|
DEFVAL { all }
|
|
::= { hardwareMIBObjects 100 }
|
|
|
|
-- Scalar:Force DSP resynchronisation
|
|
|
|
interopForceDspResync OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(100) , enable(200) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Force DSP resynchronisation
|
|
|
|
Force DSP resynchronisation for 3XXX PRI cards and 4108-16-24
|
|
platforms.
|
|
"
|
|
DEFVAL { disable }
|
|
::= { hardwareMIBObjects 200 }
|
|
|
|
-- ****************************************************************************
|
|
|
|
-- Group:Fxs
|
|
|
|
-- ****************************************************************************
|
|
|
|
fxs OBJECT IDENTIFIER
|
|
::= { hardwareMIBObjects 1000 }
|
|
-- Scalar:Ring Management
|
|
|
|
ringManagement OBJECT-TYPE
|
|
SYNTAX INTEGER { cascade(100) , simultaneous(200) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Ring Management
|
|
|
|
Configures how the ring pulse is sent on FXS ports.
|
|
|
|
* Cascade: FXS ports are prevented from ringing at the same
|
|
time in order to reduce the peak power usage of the
|
|
device.
|
|
* Simultaneous: All ports ring at the same time.
|
|
|
|
Note: This parameter is only used by the Mx4102 platform.
|
|
|
|
"
|
|
DEFVAL { cascade }
|
|
::= { fxs 100 }
|
|
|
|
-- End of group:Fxs
|
|
|
|
-- ****************************************************************************
|
|
|
|
-- Group:Pri
|
|
|
|
-- ****************************************************************************
|
|
|
|
pri OBJECT IDENTIFIER
|
|
::= { hardwareMIBObjects 2000 }
|
|
-- ***************************************************************
|
|
|
|
-- Table:PRI Ports Status
|
|
|
|
-- ***************************************************************
|
|
|
|
portsStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortsStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " PRI Ports Status
|
|
|
|
This table displays the status of each PRI port.
|
|
"
|
|
::= { pri 100 }
|
|
portsStatusEntry OBJECT-TYPE
|
|
SYNTAX PortsStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " A row in table PRI Ports Status. "
|
|
INDEX {
|
|
portsStatusPort
|
|
}
|
|
|
|
::= { portsStatusTable 1 }
|
|
|
|
PortsStatusEntry ::= SEQUENCE
|
|
{
|
|
portsStatusPort OCTET STRING,
|
|
portsStatusLineType INTEGER,
|
|
portsStatusSignaling INTEGER
|
|
}
|
|
|
|
-- Index:Port
|
|
|
|
portsStatusPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Port
|
|
|
|
Indicates the name of the port.
|
|
"
|
|
::= { portsStatusEntry 100 }
|
|
|
|
-- Columnar:Line Type
|
|
|
|
portsStatusLineType OBJECT-TYPE
|
|
SYNTAX INTEGER { e1(100) , t1(200) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Line Type
|
|
|
|
Defines the line type.
|
|
"
|
|
::= { portsStatusEntry 300 }
|
|
|
|
-- Columnar:Signaling
|
|
|
|
portsStatusSignaling OBJECT-TYPE
|
|
SYNTAX INTEGER { isdn(100) , r2(200) , eam(300) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Signaling
|
|
|
|
Defines the signaling protocol used by this port.
|
|
"
|
|
::= { portsStatusEntry 400 }
|
|
|
|
-- End of table:PRI Ports Status
|
|
|
|
-- ***************************************************************************
|
|
|
|
-- Table:PRI Ports Configuration
|
|
|
|
-- ***************************************************************************
|
|
|
|
portsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF PortsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " PRI Ports Configuration
|
|
|
|
The settings of each PRI port are configured in this table.
|
|
"
|
|
::= { pri 200 }
|
|
portsEntry OBJECT-TYPE
|
|
SYNTAX PortsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " A row in table PRI Ports Configuration. "
|
|
INDEX {
|
|
portsPort
|
|
}
|
|
|
|
::= { portsTable 1 }
|
|
|
|
PortsEntry ::= SEQUENCE
|
|
{
|
|
portsPort OCTET STRING,
|
|
portsLineType INTEGER,
|
|
portsSignaling INTEGER
|
|
}
|
|
|
|
-- Index:Port
|
|
|
|
portsPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Port
|
|
|
|
Indicates the name of the port.
|
|
"
|
|
::= { portsEntry 100 }
|
|
|
|
-- Columnar:Line Type
|
|
|
|
portsLineType OBJECT-TYPE
|
|
SYNTAX INTEGER { e1(100) , t1(200) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Line Type
|
|
|
|
Defines the line type.
|
|
|
|
* T1: DS1 T-Carrier Signaling
|
|
* E1: E1 E-Carrier Signaling
|
|
|
|
Note: The value T1 is not valid when the Ports.Signaling
|
|
parameter is set to R2.
|
|
|
|
"
|
|
DEFVAL { e1 }
|
|
::= { portsEntry 300 }
|
|
|
|
-- Columnar:Signaling
|
|
|
|
portsSignaling OBJECT-TYPE
|
|
SYNTAX INTEGER { isdn(100) , r2(200) , eam(300) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Signaling
|
|
|
|
Defines the signaling protocol used by this port.
|
|
|
|
* Isdn: Integrated Services Digital Network
|
|
* R2: E1-R2 CAS signaling protocol.
|
|
* Eam: E&M CAS signaling protocol.
|
|
|
|
Note: The value R2 is not valid when the Ports.LineType
|
|
parameter is set to T1.
|
|
|
|
"
|
|
DEFVAL { isdn }
|
|
::= { portsEntry 400 }
|
|
|
|
-- End of table:PRI Ports Configuration
|
|
|
|
-- ***************************************************************************
|
|
|
|
-- Group:PRI Statistics Group
|
|
|
|
-- ***************************************************************************
|
|
|
|
statisticsGroup OBJECT IDENTIFIER
|
|
::= { pri 1000 }
|
|
-- ***************************************************************************
|
|
|
|
-- Table:
|
|
|
|
-- ***************************************************************************
|
|
|
|
statsInfoTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF StatsInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION "
|
|
|
|
Statistics table of each PRI port.
|
|
"
|
|
::= { statisticsGroup 100 }
|
|
statsInfoEntry OBJECT-TYPE
|
|
SYNTAX StatsInfoEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " A row in table . "
|
|
INDEX {
|
|
statsInfoPort
|
|
}
|
|
|
|
::= { statsInfoTable 1 }
|
|
|
|
StatsInfoEntry ::= SEQUENCE
|
|
{
|
|
statsInfoPort OCTET STRING,
|
|
statsInfoFramesTransmitted Unsigned32,
|
|
statsInfoFramesReceived Unsigned32,
|
|
statsInfoOctetsTransmitted Unsigned32,
|
|
statsInfoOctetsReceived Unsigned32,
|
|
statsInfoFcsErrors Unsigned32,
|
|
statsInfoFramesDropped Unsigned32,
|
|
statsInfoOctetsDropped Unsigned32,
|
|
statsInfoNegativeFrameSlipsTransmitted Unsigned32,
|
|
statsInfoNegativeFrameSlipsReceived Unsigned32,
|
|
statsInfoPositiveFrameSlipsTransmitted Unsigned32,
|
|
statsInfoPositiveFrameSlipsReceived Unsigned32,
|
|
statsInfoFramingErrors Unsigned32,
|
|
statsInfoCodeViolations Unsigned32,
|
|
statsInfoCRCErrors Unsigned32,
|
|
statsInfoEBitErrors Unsigned32,
|
|
statsInfoBlockErrors Unsigned32,
|
|
statsInfoResetStats INTEGER
|
|
}
|
|
|
|
-- Index:Port
|
|
|
|
statsInfoPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Port
|
|
|
|
The name of the port.
|
|
"
|
|
::= { statsInfoEntry 100 }
|
|
|
|
-- Columnar:Negative Frame Slips Received
|
|
|
|
statsInfoNegativeFrameSlipsReceived OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Negative Frame Slips Received
|
|
|
|
A frame is skipped when the frequency of the received route
|
|
clock is greater than the frequency of the receive system
|
|
interface working clock (2.048 MHz on E1 or 1.544 MHz on T1).
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 1000 }
|
|
|
|
-- Row command:Reset Stats
|
|
|
|
statsInfoResetStats OBJECT-TYPE
|
|
SYNTAX INTEGER { noOp(0), resetStats(10) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Reset Stats
|
|
|
|
Resets all statistics for the specified interface.
|
|
"
|
|
DEFVAL { noOp }
|
|
::= { statsInfoEntry 10000 }
|
|
|
|
-- Columnar:Positive Frame Slips Transmitted
|
|
|
|
statsInfoPositiveFrameSlipsTransmitted OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Positive Frame Slips Transmitted
|
|
|
|
A frame is repeated when the frequency of the transmit clock
|
|
is less than the frequency of the transmit system interface
|
|
working clock (2.048 MHz on E1 or 1.544 MHz on T1).
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 1100 }
|
|
|
|
-- Columnar:Positive Frame Slips Received
|
|
|
|
statsInfoPositiveFrameSlipsReceived OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Positive Frame Slips Received
|
|
|
|
A frame is repeated when the frequency of the receive route
|
|
clock is less than the frequency of the receive system
|
|
interface working clock (2.048 MHz on E1 or 1.544 MHz on T1).
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 1200 }
|
|
|
|
-- Columnar:Framing Error
|
|
|
|
statsInfoFramingErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Framing Error
|
|
|
|
The framing error count indicates that a FAS (Frame Alignment
|
|
Signal) word has been received with an error.
|
|
|
|
The FAS-bits are present in every even frame of timeslot 0 on
|
|
E1.
|
|
|
|
The FAS-bits are present in ESF format on T1.
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 1300 }
|
|
|
|
-- Columnar:Code Violations
|
|
|
|
statsInfoCodeViolations OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Code Violations
|
|
|
|
The code violations count indicates that an encoding error on
|
|
the PCM line has been detected.
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 1400 }
|
|
|
|
-- Columnar:CRC Errors
|
|
|
|
statsInfoCRCErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " CRC Errors
|
|
|
|
The CRC errors count is incremented when a multiframe has
|
|
been received with a CRC error.
|
|
|
|
On E1, this counter is only available with the CRC line
|
|
framing format.
|
|
|
|
On T1, this counter is only available with the ESF line
|
|
framing format.
|
|
|
|
"
|
|
::= { statsInfoEntry 1500 }
|
|
|
|
-- Columnar:E-Bit Error
|
|
|
|
statsInfoEBitErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " E-Bit Error
|
|
|
|
The E-Bit error count gives information about the outgoing
|
|
transmit PCM line if the E-bits are used by the remote end
|
|
for submultiframe error indication. Incrementing is only
|
|
possible in the multiframe synchronous state.
|
|
|
|
Due to signaling requirements, the E-bits of frame 13 and
|
|
frame 15 of the CRC multiframe can be used to indicate an
|
|
error in a received submultiframes:
|
|
|
|
* Submultiframe I status E-bit located in frame 13
|
|
* Submultiframe II status E-bit located in frame 15
|
|
* no CRC error: E = 1
|
|
* CRC error: E = 0
|
|
|
|
This value is only available in E1.
|
|
|
|
"
|
|
::= { statsInfoEntry 1600 }
|
|
|
|
-- Columnar:Block Error
|
|
|
|
statsInfoBlockErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Block Error
|
|
|
|
The Block Error count is incremented once per multiframe if a
|
|
multiframe has been received with a CRC error or if a bad
|
|
frame alignment has been detected.
|
|
|
|
This value is only available for ESF format on T1 only.
|
|
|
|
"
|
|
::= { statsInfoEntry 1700 }
|
|
|
|
-- Columnar:Frames Transmitted
|
|
|
|
statsInfoFramesTransmitted OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Frames Transmitted
|
|
|
|
Number of HDLC frames transmitted.
|
|
|
|
Note: Frames do not refer to the structure defined in I.431.
|
|
|
|
"
|
|
::= { statsInfoEntry 200 }
|
|
|
|
-- Columnar:Frames Received
|
|
|
|
statsInfoFramesReceived OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Frames Received
|
|
|
|
Number of HDLC frames received.
|
|
|
|
Note: Frames do not refer to the structure defined in I.431.
|
|
|
|
"
|
|
::= { statsInfoEntry 300 }
|
|
|
|
-- Columnar:Octets Transmitted
|
|
|
|
statsInfoOctetsTransmitted OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Octets Transmitted
|
|
|
|
Number of octets transmitted. This value is obtained by
|
|
cumulating the octets transmitted in the HDLC frames.
|
|
|
|
Note: Frames do not refer to the structure defined in I.431.
|
|
|
|
"
|
|
::= { statsInfoEntry 400 }
|
|
|
|
-- Columnar:Octets Received
|
|
|
|
statsInfoOctetsReceived OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Octets Received
|
|
|
|
Number of octets received. This value is obtained by
|
|
cumulating the octets received in the HDLC frames.
|
|
|
|
Note: Frames do not refer to the structure defined in I.431.
|
|
|
|
"
|
|
::= { statsInfoEntry 500 }
|
|
|
|
-- Columnar:FCS Errors
|
|
|
|
statsInfoFcsErrors OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " FCS Errors
|
|
|
|
Frame check sequence (FCS) errors indicate that frames of
|
|
data are being corrupted during transmission. FCS error count
|
|
is the number of frames that were received with a bad
|
|
checksum (CRC value) in the HDLC frame. These frames are
|
|
dropped and not propagated to the upper layers.
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 600 }
|
|
|
|
-- Columnar:Frames Dropped
|
|
|
|
statsInfoFramesDropped OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Frames Dropped
|
|
|
|
Number of frames dropped. This value is obtained by
|
|
cumulating the number of frames dropped when transferring
|
|
data from the framer chip to the device internal buffer.
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 700 }
|
|
|
|
-- Columnar:Octets Dropped
|
|
|
|
statsInfoOctetsDropped OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Octets Dropped
|
|
|
|
Number of octets dropped. This value is obtained by
|
|
cumulating the number of octets dropped when transferring
|
|
data from the framer chip to the device internal buffer.
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 800 }
|
|
|
|
-- Columnar:Negative Frame Slips Transmitted
|
|
|
|
statsInfoNegativeFrameSlipsTransmitted OBJECT-TYPE
|
|
SYNTAX Unsigned32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Negative Frame Slips Transmitted
|
|
|
|
A frame is skipped when the frequency of the transmit clock
|
|
is greater than the frequency of the transmit system
|
|
interface working clock (2.048 MHz on E1 or 1.544 MHz on T1).
|
|
|
|
This value is available on E1 and T1.
|
|
|
|
"
|
|
::= { statsInfoEntry 900 }
|
|
|
|
-- End of table:
|
|
|
|
-- End of group:PRI Statistics Group
|
|
|
|
-- End of group:Pri
|
|
|
|
-- ****************************************************************************
|
|
|
|
-- Group:Bri
|
|
|
|
-- ****************************************************************************
|
|
|
|
bri OBJECT IDENTIFIER
|
|
::= { hardwareMIBObjects 3000 }
|
|
-- ***************************************************************************
|
|
|
|
-- Table:BRI Ports Status
|
|
|
|
-- ***************************************************************************
|
|
|
|
briPortsStatusTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BriPortsStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " BRI Ports Status
|
|
|
|
This table displays the status of each BRI port.
|
|
"
|
|
::= { bri 100 }
|
|
briPortsStatusEntry OBJECT-TYPE
|
|
SYNTAX BriPortsStatusEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " A row in table BRI Ports Status. "
|
|
INDEX {
|
|
briPortsStatusPort
|
|
}
|
|
|
|
::= { briPortsStatusTable 1 }
|
|
|
|
BriPortsStatusEntry ::= SEQUENCE
|
|
{
|
|
briPortsStatusPort OCTET STRING,
|
|
briPortsStatusPowerFeeding INTEGER
|
|
}
|
|
|
|
-- Index:Port
|
|
|
|
briPortsStatusPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Port
|
|
|
|
Indicates the name of the port.
|
|
"
|
|
::= { briPortsStatusEntry 100 }
|
|
|
|
-- Columnar:Power Feeding State
|
|
|
|
briPortsStatusPowerFeeding OBJECT-TYPE
|
|
SYNTAX INTEGER { on(100) , off(200) , unavailable(300) , unsupported
|
|
(400) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Power Feeding State
|
|
|
|
Indicates the state of the power feeding for the port.
|
|
|
|
* On: Power is fed to the line.
|
|
* Off: Power is not fed to the line.
|
|
* Unavailable: The power feeding feature is unavailable on
|
|
TE endpoints.
|
|
* Unsupported: The power feeding feature is not physically
|
|
supported on this port.
|
|
|
|
"
|
|
::= { briPortsStatusEntry 200 }
|
|
|
|
-- End of table:BRI Ports Status
|
|
|
|
-- ************************************************************************
|
|
|
|
-- Table:BRI Ports Configuration
|
|
|
|
-- ************************************************************************
|
|
|
|
briPortsTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF BriPortsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " BRI Ports Configuration
|
|
|
|
The settings of each BRI port are configured in this table.
|
|
"
|
|
::= { bri 200 }
|
|
briPortsEntry OBJECT-TYPE
|
|
SYNTAX BriPortsEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION " A row in table BRI Ports Configuration. "
|
|
INDEX {
|
|
briPortsPort
|
|
}
|
|
|
|
::= { briPortsTable 1 }
|
|
|
|
BriPortsEntry ::= SEQUENCE
|
|
{
|
|
briPortsPort OCTET STRING,
|
|
briPortsPowerFeedingEnable MxEnableState
|
|
}
|
|
|
|
-- Index:Port
|
|
|
|
briPortsPort OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Port
|
|
|
|
Indicates the name of the port.
|
|
"
|
|
::= { briPortsEntry 100 }
|
|
|
|
-- Columnar:Power Feeding Enable
|
|
|
|
briPortsPowerFeedingEnable OBJECT-TYPE
|
|
SYNTAX MxEnableState
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Power Feeding Enable
|
|
|
|
Enables or disables the power feeding for the port.
|
|
"
|
|
DEFVAL { disable }
|
|
::= { briPortsEntry 200 }
|
|
|
|
-- End of table:BRI Ports Configuration
|
|
|
|
-- End of group:Bri
|
|
|
|
-- ****************************************************************************
|
|
|
|
-- Group:Clock Reference
|
|
|
|
-- ****************************************************************************
|
|
|
|
clockReference OBJECT IDENTIFIER
|
|
::= { hardwareMIBObjects 5000 }
|
|
-- Scalar:Clock Reference List
|
|
|
|
clockReferenceList OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Clock Reference List
|
|
|
|
List of available clock references.
|
|
|
|
The SYNCIN value means the internal clock is synchronised with
|
|
the SYNC IN port (on platforms equipped with this port).
|
|
|
|
"
|
|
::= { clockReference 100 }
|
|
|
|
-- Scalar:Clock Reference Source
|
|
|
|
clockReferenceSource OBJECT-TYPE
|
|
SYNTAX OCTET STRING ( SIZE(0..255) )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Clock Reference Source
|
|
|
|
Indicates the preferred synchronisation source(s) to use for
|
|
the internal clock. Refer to the ClockReferenceList parameter
|
|
for a list of available clock references for the platform.
|
|
|
|
When the value is empty, the platform will automatically
|
|
choose the synchronisation source.
|
|
|
|
When a source or a list of sources are specified, the internal
|
|
clock is synchronised with the first source that offers a
|
|
valid signal. The only exception is the SYNCIN port (not
|
|
present on all platforms), which is always used when
|
|
encountered in the list.
|
|
|
|
Depending on the platform, two string separators may be used:
|
|
|
|
* ',' (comma): List synchronisation sources, per priority
|
|
(Sentinel and G7 platforms only).
|
|
* ';' (semicolon): Adding a second synchronisation source
|
|
(3xxx platform only)
|
|
|
|
Examples:
|
|
|
|
* For 44xx: 'Bri1'
|
|
* For C7xx: 'BRI1, BRI2'
|
|
* For 3xxx: 'Slot2/E1T1'
|
|
* For 3xxx: 'Slot2/Bri0; Slot3/Bri2'
|
|
* For Sentinel 400: 'Slot1/E1T1, Slot2/BRI1, Slot2/BRI2,
|
|
SYNCIN'
|
|
* For Sentinel 100 and G7: 'BRI1, BRI2, PRI1, PRI2, SYNCIN'
|
|
* Any platform: ''
|
|
|
|
"
|
|
DEFVAL { "" }
|
|
::= { clockReference 200 }
|
|
|
|
-- Scalar:Current synchronisation Reference
|
|
|
|
clockReferenceStatus OBJECT-TYPE
|
|
SYNTAX OCTET STRING
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Current synchronisation Reference
|
|
|
|
Indicates the synchronisation source currently in use.
|
|
|
|
On the 3xxx platform, up to two clock reference statuses can
|
|
be displayed.
|
|
|
|
On all other platforms, only one clock reference status is
|
|
displayed.
|
|
|
|
The 'None' value means the internal clock is not synchronised.
|
|
|
|
"
|
|
::= { clockReference 300 }
|
|
|
|
-- End of group:Clock Reference
|
|
|
|
-- ****************************************************************************
|
|
|
|
-- Group:Eth
|
|
|
|
-- ****************************************************************************
|
|
|
|
eth OBJECT IDENTIFIER
|
|
::= { hardwareMIBObjects 10000 }
|
|
-- Scalar:Ports Configuration
|
|
|
|
portsConfiguration OBJECT-TYPE
|
|
SYNTAX INTEGER { separate(100) , bridge(200) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Ports Configuration
|
|
|
|
Configures how each port provides a link interface.
|
|
|
|
* Separate: Each Ethernet port provides an independent link
|
|
interface. This is the required configuration for IP
|
|
Routing.
|
|
* Bridge: Both Ethernet ports are bridged together and
|
|
provide a single link interface.
|
|
|
|
Note: This feature is only available on units with a total of
|
|
2 Ethernet ports.
|
|
|
|
"
|
|
DEFVAL { separate }
|
|
::= { eth 100 }
|
|
|
|
-- Scalar:Kernel Network Priority
|
|
|
|
kernelNetworkPriority OBJECT-TYPE
|
|
SYNTAX Unsigned32 ( 0..100 )
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Kernel Network Priority
|
|
|
|
Controls the network priority in the kernel. The default value
|
|
is platform-dependent. This parameter should not be
|
|
altered, unless advised otherwise by a technical support
|
|
specialist.
|
|
"
|
|
DEFVAL { 10 }
|
|
::= { eth 200 }
|
|
|
|
-- End of group:Eth
|
|
|
|
-- **************************************
|
|
|
|
-- Group:Debug Group
|
|
|
|
-- **************************************
|
|
|
|
debugGroup OBJECT IDENTIFIER
|
|
::= { hardwareMIBObjects 50000 }
|
|
-- End of group:Debug Group
|
|
|
|
-- ****************************************************************************
|
|
|
|
-- Group:Notification Messages Configuration
|
|
|
|
-- ****************************************************************************
|
|
|
|
notificationsGroup OBJECT IDENTIFIER
|
|
::= { hardwareMIBObjects 60010 }
|
|
-- Scalar:Minimal Severity of Notification
|
|
|
|
minSeverity OBJECT-TYPE
|
|
SYNTAX INTEGER { disable(0) , debug(100) , info(200) , warning(300) ,
|
|
error(400) , critical (500) }
|
|
MAX-ACCESS read-write
|
|
STATUS current
|
|
DESCRIPTION " Minimal Severity of Notification
|
|
|
|
Sets the minimal severity to issue a notification message
|
|
incoming from this service.
|
|
|
|
* Disable: No notification is issued.
|
|
* Debug: All notification messages are issued.
|
|
* Info: Notification messages with a 'Informational' and
|
|
higher severity are issued.
|
|
* Warning: Notification messages with a 'Warning' and higher
|
|
severity are issued.
|
|
* Error: Notification messages with an 'Error' and higher
|
|
severity are issued.
|
|
* Critical: Notification messages with a 'Critical' severity
|
|
are issued.
|
|
|
|
"
|
|
DEFVAL { warning }
|
|
::= { notificationsGroup 100 }
|
|
|
|
-- End of group:Notification Messages Configuration
|
|
|
|
-- ****************************************************************************
|
|
|
|
-- Group:Configuration Settings
|
|
|
|
-- ****************************************************************************
|
|
|
|
configurationGroup OBJECT IDENTIFIER
|
|
::= { hardwareMIBObjects 60020 }
|
|
-- Scalar:Need Restart
|
|
|
|
needRestartInfo OBJECT-TYPE
|
|
SYNTAX INTEGER { no(0) , yes(100) }
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION " Need Restart
|
|
|
|
Indicates if the service needs to be restarted for the
|
|
configuration to fully take effect.
|
|
|
|
* Yes: Service needs to be restarted.
|
|
* No: Service does not need to be restarted.
|
|
|
|
Services can be restarted by using the
|
|
Scm.ServiceCommands.Restart command.
|
|
|
|
"
|
|
::= { configurationGroup 100 }
|
|
|
|
-- End of group:Configuration Settings
|
|
|
|
END
|