-- MAIPU-FRAMERELAY.mib: Maipu enterprise device Frame-Relay MIB file
|
|
--
|
|
--version 1.0.0.0, Feb 15, 2001 Huanglulu
|
|
--
|
|
-- Copyright (c) by Maipu DataComm Inc.
|
|
-- All rights reserved.
|
|
--
|
|
-- *****************************************************************
|
|
--
|
|
|
|
MAIPU-FR-MIB DEFINITIONS ::= BEGIN
|
|
|
|
IMPORTS
|
|
RowStatus, DisplayString FROM SNMPv2-TC
|
|
MODULE-IDENTITY, OBJECT-TYPE,
|
|
IpAddress, OBJECT-IDENTITY, Counter32 FROM SNMPv2-SMI
|
|
mpMgmt FROM MAIPU-SMI;
|
|
|
|
mpFrMib MODULE-IDENTITY
|
|
LAST-UPDATED "0102160000Z"
|
|
ORGANIZATION "Maipu DataComm"
|
|
CONTACT-INFO
|
|
" Maipu DataComm
|
|
Customer Service
|
|
|
|
Postal: Consulate Drive
|
|
Chengdu, Sichuan 610041
|
|
China
|
|
|
|
Tel: 86-028-5161006
|
|
|
|
E-mail: office@maipu.com"
|
|
DESCRIPTION
|
|
"The assignments for Maipu router's MIB of Frame-Relay infomation!"
|
|
::= {mpMgmt 6 }
|
|
|
|
frIfMib OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口上的帧中继协议."
|
|
::= { mpFrMib 1 }
|
|
|
|
frPvcMib OBJECT-IDENTITY
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口上的帧中继PVC."
|
|
::= { mpFrMib 2 }
|
|
|
|
--frMapMib OBJECT-IDENTITY
|
|
-- STATUS current
|
|
-- DESCRIPTION
|
|
-- "接口上的帧中继地址映射."
|
|
-- ::= { mpFrMib 3 }
|
|
|
|
--//***********if configure********//
|
|
frConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继协议的接口配置表."
|
|
::= { frIfMib 1 }
|
|
|
|
frConfEntry OBJECT-TYPE
|
|
SYNTAX FrConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继协议的接口配置表条目."
|
|
INDEX { frConfIfIndex }
|
|
::= { frConfTable 1 }
|
|
|
|
FrConfEntry ::=
|
|
SEQUENCE {
|
|
frConfIfIndex
|
|
INTEGER,
|
|
frConfIfType
|
|
INTEGER,
|
|
frConfIfStatus
|
|
RowStatus
|
|
}
|
|
|
|
frConfIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"配置帧中继协议的接口的接口索引,与ifIndex相同."
|
|
::= { frConfEntry 1 }
|
|
|
|
frConfIfType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
dte(1),
|
|
dce(2),
|
|
nni(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继接口的工作方式."
|
|
DEFVAL { dte }
|
|
::= { frConfEntry 2 }
|
|
|
|
frConfIfStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继接口配置表行状态."
|
|
::= { frConfEntry 3 }
|
|
|
|
--//***********frLmi configuration********//
|
|
frLmiConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrLmiConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继LMI协议接口配置表."
|
|
::= { frIfMib 2 }
|
|
|
|
frLmiConfEntry OBJECT-TYPE
|
|
SYNTAX FrLmiConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继LMI协议的接口配置表条目."
|
|
INDEX { frLmiConfIfIndex }
|
|
::= { frLmiConfTable 1 }
|
|
|
|
FrLmiConfEntry ::=
|
|
SEQUENCE {
|
|
frLmiConfIfIndex
|
|
INTEGER,
|
|
frLmiType
|
|
INTEGER,
|
|
frLmiN391Dte
|
|
INTEGER,
|
|
frLmiN392Dte
|
|
INTEGER,
|
|
frLmiN393Dte
|
|
INTEGER,
|
|
frLmiN392Dce
|
|
INTEGER,
|
|
frLmiN393Dce
|
|
INTEGER,
|
|
frLmiT392Dce
|
|
INTEGER,
|
|
frLmiKeepalive
|
|
INTEGER,
|
|
frLmiConfStatus
|
|
RowStatus
|
|
}
|
|
|
|
frLmiConfIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继lmi协议的接口索引,与ifIndex相同."
|
|
::= { frLmiConfEntry 1 }
|
|
|
|
frLmiType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ansi(1),
|
|
q933a(2),
|
|
lmi(3)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继lmi方式."
|
|
DEFVAL { ansi }
|
|
::= { frLmiConfEntry 2 }
|
|
|
|
frLmiN391Dte OBJECT-TYPE
|
|
SYNTAX INTEGER (1..255)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"请求PVC状态的计数器."
|
|
::= { frLmiConfEntry 3 }
|
|
|
|
frLmiN392Dte OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DTE错误阈值."
|
|
::= { frLmiConfEntry 4 }
|
|
|
|
frLmiN393Dte OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DTE事件计数器.这个值不能小于frN392Dte."
|
|
::= { frLmiConfEntry 5 }
|
|
|
|
frLmiN392Dce OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DCE错误阈值."
|
|
::= { frLmiConfEntry 6 }
|
|
|
|
frLmiN393Dce OBJECT-TYPE
|
|
SYNTAX INTEGER (1..10)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DCE事件计数器.这个值不能小于frN392Dce."
|
|
::= { frLmiConfEntry 7 }
|
|
|
|
frLmiT392Dce OBJECT-TYPE
|
|
SYNTAX INTEGER (5..30)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"DCE轮询定时器."
|
|
::= { frLmiConfEntry 8 }
|
|
|
|
frLmiKeepalive OBJECT-TYPE
|
|
SYNTAX INTEGER (0..32767)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"发送保活帧的间隔时间,为0则表示不发送保活帧."
|
|
::= { frLmiConfEntry 9 }
|
|
|
|
frLmiConfStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继LMI协议行状态."
|
|
::= { frLmiConfEntry 10 }
|
|
|
|
--//***********frLmi statistics*****************
|
|
frLmiStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrLmiStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继LMI协议的统计表."
|
|
::= { frIfMib 3 }
|
|
|
|
frLmiStatEntry OBJECT-TYPE
|
|
SYNTAX FrLmiStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继LMI协议统计表条目."
|
|
INDEX { frLmiStatIfIndex }
|
|
::= { frLmiStatTable 1 }
|
|
|
|
FrLmiStatEntry ::=
|
|
SEQUENCE {
|
|
frLmiStatIfIndex
|
|
INTEGER,
|
|
frLmiStEnqSent
|
|
Counter32,
|
|
frLmiStMsgRecv
|
|
Counter32,
|
|
frLmiStTimeout
|
|
Counter32,
|
|
frLmiStEnqRecv
|
|
Counter32,
|
|
frLmiStMsgSent
|
|
Counter32,
|
|
frLmiStEnqTimeout
|
|
Counter32
|
|
}
|
|
|
|
frLmiStatIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继LMI协议统计表的索引,用ifIndex值."
|
|
::= { frLmiStatEntry 1 }
|
|
|
|
frLmiStEnqSent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"发送的状态请求报文的数目"
|
|
::= { frLmiStatEntry 2 }
|
|
|
|
frLmiStMsgRecv OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"收到的状态相应报文的数目"
|
|
::= { frLmiStatEntry 3 }
|
|
|
|
frLmiStTimeout OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"状态请求报文超时的数目"
|
|
::= { frLmiStatEntry 4 }
|
|
|
|
frLmiStEnqRecv OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"收到的状态请求报文的数目"
|
|
::= { frLmiStatEntry 5 }
|
|
|
|
frLmiStMsgSent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"发送的状态相应报文的数目"
|
|
::= { frLmiStatEntry 6 }
|
|
|
|
frLmiStEnqTimeout OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"状态相应报文超时的数目"
|
|
::= { frLmiStatEntry 7 }
|
|
|
|
--//************frInarp configuration*****************
|
|
frInarpConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrInarpConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继InArp协议配置表."
|
|
::= { frIfMib 4 }
|
|
|
|
frInarpConfEntry OBJECT-TYPE
|
|
SYNTAX FrInarpConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继InArp协议配置表条目."
|
|
INDEX { frInarpConfIfIndex }
|
|
::= { frInarpConfTable 1 }
|
|
|
|
FrInarpConfEntry ::=
|
|
SEQUENCE {
|
|
frInarpConfIfIndex
|
|
INTEGER,
|
|
frInarpEnable
|
|
INTEGER,
|
|
frInarpInterval
|
|
INTEGER,
|
|
frInarpUpdate
|
|
INTEGER,
|
|
frInarpStatus
|
|
RowStatus
|
|
}
|
|
|
|
frInarpConfIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"配置InArp协议的接口的索引,与ifIndex相同."
|
|
::= { frInarpConfEntry 1 }
|
|
|
|
frInarpEnable OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
enable(1),
|
|
disable(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"是否在接口上启用InARP协议."
|
|
DEFVAL { disable }
|
|
::= { frInarpConfEntry 2 }
|
|
|
|
frInarpInterval OBJECT-TYPE
|
|
SYNTAX INTEGER (15..300)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"发送InARP请求的时间间隔."
|
|
::= { frInarpConfEntry 3 }
|
|
|
|
frInarpUpdate OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"是否周期性的更新动态地址映射."
|
|
DEFVAL { disable }
|
|
::= { frInarpConfEntry 4 }
|
|
|
|
frInarpStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继Inarp协议配置表行状态."
|
|
::= { frInarpConfEntry 5 }
|
|
|
|
--//************frInarp statistics*****************
|
|
frInarpStatTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrInarpStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继InArp协议统计表."
|
|
::= { frIfMib 5 }
|
|
|
|
frInarpStatEntry OBJECT-TYPE
|
|
SYNTAX FrInarpStatEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"帧中继InArp协议统计表条目."
|
|
INDEX { frInarpConfIfIndex }
|
|
::= { frInarpStatTable 1 }
|
|
|
|
FrInarpStatEntry ::=
|
|
SEQUENCE {
|
|
frInarpStatIfIndex
|
|
INTEGER,
|
|
frInarpReqSent
|
|
Counter32,
|
|
frInarpReqRecv
|
|
Counter32,
|
|
frInarpReplySent
|
|
Counter32,
|
|
frInarpReplyRecv
|
|
Counter32
|
|
}
|
|
|
|
frInarpStatIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"InArp统计表的索引,用接口的索引值,与ifIndex相同."
|
|
::= { frInarpStatEntry 1 }
|
|
|
|
frInarpReqSent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"发送的InArp请求数."
|
|
::= { frInarpStatEntry 2 }
|
|
|
|
frInarpReqRecv OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接收的InArp请求数."
|
|
::= { frInarpStatEntry 3 }
|
|
|
|
frInarpReplySent OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"发送的InArp应答数."
|
|
::= { frInarpStatEntry 4 }
|
|
|
|
frInarpReplyRecv OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接收的InArp应答数."
|
|
::= { frInarpStatEntry 5 }
|
|
|
|
--//*******fr pvc configuration**************
|
|
frPvcConfTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrPvcConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口上的PVC配置表."
|
|
::= { frPvcMib 1 }
|
|
|
|
frPvcConfEntry OBJECT-TYPE
|
|
SYNTAX FrPvcConfEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口上的数据链路标识表条目."
|
|
INDEX { frPvcConfIfIndex, frPvcConfDlci }
|
|
::= { frPvcConfTable 1 }
|
|
|
|
FrPvcConfEntry ::=
|
|
SEQUENCE {
|
|
frPvcConfIfIndex
|
|
INTEGER,
|
|
frPvcConfDlci
|
|
INTEGER,
|
|
frPvcIntf
|
|
DisplayString,
|
|
frPvcUsage
|
|
INTEGER,
|
|
frPvcStatus
|
|
INTEGER,
|
|
frPvcEncType
|
|
INTEGER,
|
|
frPvcMapIp
|
|
IpAddress,
|
|
frPvcMapType
|
|
INTEGER,
|
|
frPvcRouteOutIntf
|
|
DisplayString,
|
|
frPvcRouteOutDlci
|
|
INTEGER,
|
|
frPvcRouteStatus
|
|
INTEGER,
|
|
frPvcBroadcast
|
|
INTEGER,
|
|
frPvcNoInarpIp
|
|
INTEGER,
|
|
frPvcGetFromDce
|
|
INTEGER,
|
|
frPvcConfTableStatus
|
|
RowStatus
|
|
}
|
|
|
|
frPvcConfIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口索引,与ifIndex相同."
|
|
::= { frPvcConfEntry 1 }
|
|
|
|
frPvcConfDlci OBJECT-TYPE
|
|
SYNTAX INTEGER (16..1007)
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口上的数据链路标识dlci."
|
|
::= { frPvcConfEntry 2 }
|
|
|
|
frPvcIntf OBJECT-TYPE
|
|
SYNTAX DisplayString(SIZE(1..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC的接口名字."
|
|
::= { frPvcConfEntry 3 }
|
|
|
|
frPvcUsage OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
local(1),
|
|
switched(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC的用途."
|
|
DEFVAL { local }
|
|
::= { frPvcConfEntry 4 }
|
|
|
|
frPvcStatus OBJECT-TYPE
|
|
SYNTAX INTEGER{
|
|
inActive(1),
|
|
active(2),
|
|
static(3),
|
|
deleted(4),
|
|
defined(5)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC的状态."
|
|
::= { frPvcConfEntry 5 }
|
|
|
|
frPvcEncType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
ietf(1),
|
|
cisco(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC的封装类型."
|
|
DEFVAL { ietf }
|
|
::= { frPvcConfEntry 6 }
|
|
|
|
frPvcMapIp OBJECT-TYPE
|
|
SYNTAX IpAddress
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC映射的IP地址."
|
|
::= { frPvcConfEntry 7 }
|
|
|
|
frPvcMapType OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
static(1),
|
|
dynamic(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC地址映射的类型."
|
|
DEFVAL {static}
|
|
::= { frPvcConfEntry 8 }
|
|
|
|
frPvcRouteOutIntf OBJECT-TYPE
|
|
SYNTAX DisplayString (SIZE(1..255))
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC路由的输出接口."
|
|
::= { frPvcConfEntry 9 }
|
|
|
|
frPvcRouteOutDlci OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC路由的输出DLCI."
|
|
::= { frPvcConfEntry 10 }
|
|
|
|
frPvcRouteStatus OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
inactive(1),
|
|
active(2),
|
|
static(3)
|
|
}
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC路由的状态."
|
|
::= { frPvcConfEntry 11 }
|
|
|
|
frPvcBroadcast OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC是否支持广播."
|
|
DEFVAL {disable }
|
|
::= { frPvcConfEntry 12 }
|
|
|
|
frPvcNoInarpIp OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
disable(1),
|
|
enable(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC是否支持InARP协议."
|
|
DEFVAL {disable }
|
|
::= { frPvcConfEntry 13 }
|
|
|
|
frPvcGetFromDce OBJECT-TYPE
|
|
SYNTAX INTEGER {
|
|
false(1),
|
|
true(2)
|
|
}
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC是否从DCE自动获取的."
|
|
DEFVAL {false }
|
|
::= { frPvcConfEntry 14 }
|
|
|
|
frPvcConfTableStatus OBJECT-TYPE
|
|
SYNTAX RowStatus
|
|
MAX-ACCESS read-create
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口上的数据链路标识表的行状态,用于增加,删除或修改一行的内容."
|
|
::= { frPvcConfEntry 15 }
|
|
|
|
--//**********fr pvc statistics**********
|
|
frPvcStaticTable OBJECT-TYPE
|
|
SYNTAX SEQUENCE OF FrPvcStaticEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口上的PVC统计表."
|
|
::= { frPvcMib 2 }
|
|
|
|
frPvcStaticEntry OBJECT-TYPE
|
|
SYNTAX FrPvcStaticEntry
|
|
MAX-ACCESS not-accessible
|
|
STATUS current
|
|
DESCRIPTION
|
|
"接口上的PVC统计表条目."
|
|
INDEX { frPvcStatIfIndex, frPvcStatDlci }
|
|
::= { frPvcStaticTable 1 }
|
|
|
|
FrPvcStaticEntry ::=
|
|
SEQUENCE {
|
|
frPvcStatIfIndex
|
|
INTEGER,
|
|
frPvcStatDlci
|
|
INTEGER,
|
|
frPvcStatInPkts
|
|
Counter32,
|
|
frPvcStatOutPkts
|
|
Counter32,
|
|
frPvcStatInBytes
|
|
Counter32,
|
|
frPvcStatOutBytes
|
|
Counter32,
|
|
frPvcStatDroppedPkts
|
|
Counter32,
|
|
frPvcStatInFecnPkts
|
|
Counter32,
|
|
frPvcStatOutFecnPkts
|
|
Counter32,
|
|
frPvcStatInBecnPkts
|
|
Counter32,
|
|
frPvcStatOutBecnPkts
|
|
Counter32,
|
|
frPvcStatInDePkts
|
|
Counter32,
|
|
frPvcStatOutDePkts
|
|
Counter32,
|
|
frPvcSwitchPkts
|
|
Counter32
|
|
}
|
|
|
|
frPvcStatIfIndex OBJECT-TYPE
|
|
SYNTAX INTEGER
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC统计表的接口索引,与ifIndex相同."
|
|
::= { frPvcStaticEntry 1 }
|
|
|
|
frPvcStatDlci OBJECT-TYPE
|
|
SYNTAX INTEGER (16..1007)
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC的dlci值."
|
|
::= { frPvcStaticEntry 2 }
|
|
|
|
frPvcStatInPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输入分组的数目。"
|
|
::= { frPvcStaticEntry 3 }
|
|
|
|
frPvcStatOutPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输出分组的数目。"
|
|
::= { frPvcStaticEntry 4 }
|
|
|
|
frPvcStatInBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输入数据的比特数。"
|
|
::= { frPvcStaticEntry 5 }
|
|
|
|
frPvcStatOutBytes OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输出数据的比特数。"
|
|
::= { frPvcStaticEntry 6 }
|
|
|
|
frPvcStatDroppedPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC丢弃的分组数目。"
|
|
::= { frPvcStaticEntry 7 }
|
|
|
|
frPvcStatInFecnPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输入的FECN置位的分组数目。"
|
|
::= { frPvcStaticEntry 8 }
|
|
|
|
frPvcStatOutFecnPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输出的FECN置位的分组数目。"
|
|
::= { frPvcStaticEntry 9 }
|
|
|
|
frPvcStatInBecnPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输入的BECN置位的分组数目。"
|
|
::= { frPvcStaticEntry 10 }
|
|
|
|
frPvcStatOutBecnPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输出的BECN置位的分组数目。"
|
|
::= { frPvcStaticEntry 11 }
|
|
|
|
frPvcStatInDePkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输入的DE置位的分组数目。"
|
|
::= { frPvcStaticEntry 12 }
|
|
|
|
frPvcStatOutDePkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC输出的DE置位的分组数目。"
|
|
::= { frPvcStaticEntry 13 }
|
|
|
|
frPvcSwitchPkts OBJECT-TYPE
|
|
SYNTAX Counter32
|
|
MAX-ACCESS read-only
|
|
STATUS current
|
|
DESCRIPTION
|
|
"PVC交换的分组数目。"
|
|
::= { frPvcStaticEntry 14 }
|
|
|
|
END |