Observium_CE/mibs/infinera/INFINERA-PM-SECYTXSCSTATS-MIB

191 lines
6.3 KiB
Plaintext

-- *****************************************************************
-- INFINERA-PM-SECYTXSCSTATS-MIB
--
-- October 2016, Kavitha Manjunatha
--
--
-- Copyright (c) 2008-2012 by Infinera Inc.
-- All rights reserved.
-- ****************************************************************
INFINERA-PM-SECYTXSCSTATS-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE,
Integer32 FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
TruthValue FROM SNMPv2-TC
ifIndex FROM IF-MIB
HCPerfIntervalCount FROM HC-PerfHist-TC-MIB
macsecPerfMon FROM INFINERA-REG-MIB;
secyTxSCStatsPmMIB MODULE-IDENTITY
LAST-UPDATED "201502060000Z"
ORGANIZATION "Infinera"
CONTACT-INFO
"Infinera
1322 Bordeaux Drive
Sunnyvale, CA - 94089
Contact : Technical Support
Email : support@infinera.com
Phone : 1-877-INF-5288"
DESCRIPTION
" "
REVISION "201502060000Z"
DESCRIPTION
"First Version"
::= { macsecPerfMon 1 }
-- Real PMs
-- secyTxSCStatsPmRealTable OBJECT-TYPE
-- SYNTAX SEQUENCE OF SecyTxSCStatsRealEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A list of SecyTxSCStatsReal entries. Each entry is uniquely identified by the value of ifIndex."
-- ::= { secyTxSCStatsPmMIB 1 }
-- secyTxSCStatsPmRealEntry OBJECT-TYPE
-- SYNTAX SecyTxSCStatsRealEntry
-- MAX-ACCESS not-accessible
-- STATUS current
-- DESCRIPTION
-- "A secyTxSCStatsPm entry containing real-time performance information pertaining to
-- Infinera Fan interfaces. . This table is a subclass of IfCommon.
-- Entries will exist in this table only for interfaces of secyTxSCStats."
-- INDEX { ifIndex }
-- ::= { secyTxSCStatsPmRealTable 1 }
-- SecyTxSCStatsRealEntry ::= SEQUENCE {
-- }
-- Historical PMs
secyTxSCStatsPmTable OBJECT-TYPE
SYNTAX SEQUENCE OF SecyTxSCStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A list of SecyTxSCStats entries. Each entry is uniquely identified by the value of
ifIndex, sampleDuration and secyTxSCStatsPmTimestamp."
::= { secyTxSCStatsPmMIB 2 }
secyTxSCStatsPmEntry OBJECT-TYPE
SYNTAX SecyTxSCStatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A secyTxSCStatsPm entry containing historical performance information pertaining to
Infinera secyTxSCStatsPm interfaces. This table is a subclass of IfCommon.
Entries will exist in this table only for interfaces of type secyTxSCStats.
Each interface may have a number of entries in this table, each with a different combination
of timestamp and sample duration."
INDEX { ifIndex, secyTxSCStatsPmSampleDuration, secyTxSCStatsPmTimestamp }
::= { secyTxSCStatsPmTable 1 }
SecyTxSCStatsEntry ::= SEQUENCE {
secyTxSCStatsPmTimestamp Integer32,
secyTxSCStatsPmSampleDuration INTEGER,
secyTxSCStatsPmValidity TruthValue,
secyTxSCStatsPmProtectedPkts HCPerfIntervalCount,
secyTxSCStatsPmEncryptedPkts HCPerfIntervalCount,
secyTxSCStatsPmOctetsProtected HCPerfIntervalCount,
secyTxSCStatsPmOctetsEncrypted HCPerfIntervalCount
}
secyTxSCStatsPmTimestamp OBJECT-TYPE
SYNTAX Integer32 (0..2147483647)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"End Time stamp for this interval. If this time is later than the current time,
then the data for this bucket is currently being collected."
::= { secyTxSCStatsPmEntry 1 }
secyTxSCStatsPmSampleDuration OBJECT-TYPE
SYNTAX INTEGER {
fifteenMinutes(1),
day(2)
}
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The duration of this sample."
::= { secyTxSCStatsPmEntry 2 }
secyTxSCStatsPmValidity OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "Flag indicating if data was valid for the entire interval"
::= { secyTxSCStatsPmEntry 3 }
secyTxSCStatsPmProtectedPkts OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SECY TXSCStats ProtectedPkts"
::= { secyTxSCStatsPmEntry 4 }
secyTxSCStatsPmEncryptedPkts OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SECY TXSCStats EncryptedPkts"
::= { secyTxSCStatsPmEntry 5 }
secyTxSCStatsPmOctetsProtected OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SECY TXSCStats OctetsProtected"
::= { secyTxSCStatsPmEntry 6 }
secyTxSCStatsPmOctetsEncrypted OBJECT-TYPE
SYNTAX HCPerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION "SECY TXSCStats OctetsEncrypted"
::= { secyTxSCStatsPmEntry 7 }
-- Conformance Statements
secyTxSCStatsPmConformance OBJECT IDENTIFIER ::= { secyTxSCStatsPmMIB 3 }
secyTxSCStatsPmCompliances OBJECT IDENTIFIER ::= { secyTxSCStatsPmConformance 1 }
secyTxSCStatsPmGroups OBJECT IDENTIFIER ::= { secyTxSCStatsPmConformance 2 }
-- secyTxSCStatsPmRealCompliance MODULE-COMPLIANCE
-- STATUS current
-- DESCRIPTION
-- "Describes the requirements for conformance to the PM-SECYTXSCSTATS-MIB"
-- MODULE
-- MANDATORY-GROUPS { secyTxSCStatsPmRealGroup }
-- ::= { secyTxSCStatsPmCompliances 1 }
secyTxSCStatsPmCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the PM-SECYTXSCSTATS-MIB"
MODULE
MANDATORY-GROUPS { secyTxSCStatsPmGroup }
::= { secyTxSCStatsPmCompliances 2 }
-- Historical PM groups
secyTxSCStatsPmGroup OBJECT-GROUP
OBJECTS {
secyTxSCStatsPmValidity,
secyTxSCStatsPmProtectedPkts,
secyTxSCStatsPmEncryptedPkts,
secyTxSCStatsPmOctetsProtected,
secyTxSCStatsPmOctetsEncrypted
}
STATUS current
DESCRIPTION
" A collection of objects for reading SecyTxSCStats."
::= { secyTxSCStatsPmGroups 1 }
--
END